WorldWideScience

Sample records for effective endovascular stenting

  1. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  2. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  3. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  4. The management of unimplantable stent during endovascular procedure:report of three cases

    International Nuclear Information System (INIS)

    Xiong Jiang; Wang Lijun; Guo Wei; Liu Xiaoping; Yin Tai; Jia Xin; Ma Xiaohui; Liu Meng; Zhang Hongpeng; Zhang Minhong

    2010-01-01

    Objective: To summarize the experience of dealing with the difficulty of the stent implantation encountered in the endovascular procedure. Methods: The causes of unimplantable stent encountered in the endovascular procedure included the delivery system entraping due to the stenosis and shrinking of peripheral self-expandable stent, the balloon expandable stent implantation and retrievement failure due to the rupture-balloon or stent edge opening, and the delivery system entraping due to aortic stent graft for aorta kinking. The balloon dilation for the stenosis and shrinking stent, the large caliber introducer sheath for removal of the rupture-balloon and edge opening, the expandable stent and balloon-assisted delivery system retrieve were used to solve the above three dilemma of unimplantable stent occurred in the endovascular procedure. Results: These three dilemma of stent unimplantable problem in the endovascular therapy were solved by endovascular method while little additional incision injury was added to the patients. Conclusion: For solving stent unimplantable problem the endovascular technique is the method of first choice, nevertherless, it is very important for the operator to be highly skilled in manipulating endovascular procedure. (authors)

  5. Mechanical Behavior of Fully Expanded Commercially Available Endovascular Coronary Stents

    OpenAIRE

    Tambaca, Josip; Canic, Suncica; Kosor, Mate; Fish, R. David; Paniagua, David

    2011-01-01

    The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.

  6. An experimental study on expandable endovascular metallic stents in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Kim, Hak Nam [Chonbuk National University College of Medicine, Chonju (Korea, Republic of)

    1990-12-15

    We constructed an expandable endovascular metallic stent in the same way as Giamturco did. Experiments were made to test the ability of these stents to be used in the vessels. A total of 20 stents were passed through a 8.5 French teflon sheath into the normal abdominal aorta. IVC, and iliac artery of four adult dogs for 4 weeks to 12 weeks; 8 stents (10 mm in diameter fully expanded and 20 mm in length) in the abnormal aorta, 7 stents (12 mm/20 mm) in the IVC, and 5 stents (8 mm/20 mm) in the iliac artery. All but two stents showed no migration, and one complete occlusion occurred in right iliac artery of a dog. Histologically, stents wires were covered by neo-intimal proliferation. The side branches of the main vessels remained patent, even stent wires across their orifices. These metallic stents may be used as an endovascular graft material in the nonsurgical treatment of several forms of vascular disease.

  7. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  8. Short vs prolonged dual antiplatelet treatment upon endovascular stenting of peripheral arteries

    Directory of Open Access Journals (Sweden)

    Kronlage M

    2017-10-01

    suffered a stroke/transient ischemic attack (P>0.05. In addition, there was no difference regarding mortality and amputation rate comparing short vs prolonged DAPT regime in a 12-month follow-up.Conclusion: In the current cohort, prolonged DAPT after endovascular stenting had no beneficial effect on the outcome in a 12-month follow-up. Keywords: peripheral artery disease, stent implantation, dual antiplatelet therapy, primary patency, endovascular therapy

  9. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  10. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  11. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    Science.gov (United States)

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  12. Treatment of Endovascular Coil and Stent Migration Using the Merci Retriever: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    David K. Kung

    2012-01-01

    Full Text Available Background. Coil and stent migration is a potentially catastrophic complication in endovascular neurosurgery, which may lead to cerebral thromboembolism. Techniques for removing migrated coil and stent are not well established. Methods and Results. We present three cases in which coil or stent migration occurred during endovascular embolization of a cerebral aneurysm. The Merci Retrievers were used successfully in all cases to remove the displaced foreign bodies. Technical details are described. Conclusion. The Merci Retriever device can be utilized successfully for removal of migrated coils and stents in endovascular neurosurgery.

  13. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  14. Bronchoscopic guidance of endovascular stenting limits airway compression.

    Science.gov (United States)

    Ebrahim, Mohammad; Hagood, James; Moore, John; El-Said, Howaida

    2015-04-01

    Bronchial compression as a result of pulmonary artery and aortic arch stenting may cause significant respiratory distress. We set out to limit airway narrowing by endovascular stenting, by using simultaneous flexible bronchoscopy and graduated balloon stent dilatation, or balloon angioplasty to determine maximum safe stent diameter. Between August 2010 and August 2013, patients with suspected airway compression by adjacent vascular structures, underwent CT or a 3D rotational angiogram to evaluate the relationship between the airway and the blood vessels. If these studies showed close proximity of the stenosed vessel and the airway, simultaneous bronchoscopy and graduated stent re-dilation or graduated balloon angioplasty were performed. Five simultaneous bronchoscopy and interventional catheterization procedures were performed in four patients. Median age/weight was 33 (range 9-49) months and 14 (range 7.6-24) kg, respectively. Three had hypoplastic left heart syndrome, and one had coarctation of the aorta (CoA). All had confirmed or suspected left main stem bronchial compression. In three procedures, serial balloon dilatation of a previously placed stent in the CoA was performed and bronchoscopy was used to determine the safest largest diameter. In the other two procedures, balloon testing with simultaneous bronchoscopy was performed to determine the stent size that would limit compression of the adjacent airway. In all cases, simultaneous bronchoscopy allowed selection of an ideal caliber of the stent that optimized vessel diameter while minimizing compression of the adjacent airway. In cases at risk for airway compromise, flexible bronchoscopy is a useful tool to guide endovascular stenting. Maximum safe stent diameter can be determined without risking catastrophic airway compression. © 2014 Wiley Periodicals, Inc.

  15. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  16. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  17. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  18. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato, E-mail: masato03310402@yahoo.co.jp [Kobe University Hospital, Department of Radiology (Japan); Muradi, Akhmadu, E-mail: muradiakhmadu@gmail.com; Nomura, Yoshikatsu, E-mail: y_katsu1027@yahoo.co.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Uotani, Kensuke, E-mail: uotani@tenriyorozu.jp [Tenri Hospital, Department of Radiology (Japan); Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Miyamoto, Naokazu, E-mail: naoka_zu@yahoo.co.jp; Kawasaki, Ryota, E-mail: kawaryo1999@yahoo.co.jp [Hyogo Brain and Heart Center at Himeji, Department of Radiology (Japan); Taniguchi, Takanori, E-mail: tan9523929@yahoo.co.jp [Tenri Hospital, Department of Radiology (Japan); Okita, Yutaka, E-mail: yokita@med.kobe-u.ac.jp [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji, E-mail: kojirad@med.kobe-u.ac.jp [Kobe University Hospital, Department of Radiology (Japan)

    2013-08-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 {+-} 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35-1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary.

  19. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  20. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  1. Short-term curative effect of endovascular stent-graft treatment for aortic diseases in China: a systematic review.

    Directory of Open Access Journals (Sweden)

    Siwen Wang

    Full Text Available INTRODUCTION: We analyzed the short-term efficacy of endovascular treatment for aortic diseases by summarizing all available published data on endovascular stent-graft treatment for abdominal aortic aneurysm (AAA, thoracic aortic aneurysm (TAA, type A aortic dissection (type A AD and type B aortic dissection (type B AD in China. METHODS: We performed a systematic analysis of 935 published series on retrograde endovascular treatment for aortic diseases in China from January 1996 to November 2010. Based on the inclusion criteria, 159 studies, involving a total of 5531 patients, were included. RESULTS: There were no significant differences in procedural success among the studies (P>0.05. The rates of overall neurologic complications and stroke were significantly different in all two-group comparisons (P0.05. A significant difference was noted between the 30-day mortality rate of the type A AD patients and the AAA or type B AD patients (P<0.05. CONCLUSION: Endovascular stent-graft is a feasible and safe treatment for aortic diseases, with high procedural success and low incidences of post-procedural complications and short-term mortality. Endovascular treatment for AAA and type B AD is more efficient than for type A AD and TAA.

  2. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  3. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  4. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-02-15

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  5. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  6. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  7. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric

    2010-01-01

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  8. Endovascular stentectomy using the snare over stent-retriever (SOS technique: An experimental feasibility study.

    Directory of Open Access Journals (Sweden)

    Tareq Meyer

    Full Text Available Feasibility of endovascular stentectomy using a snare over stent-retriever (SOS technique was evaluated in a silicon flow model and an in vivo swine model. In vitro, stentectomy of different intracranial stents using the SOS technique was feasible in 22 out of 24 (92% retrieval maneuvers. In vivo, stentectomy was successful in 10 out of 10 procedures (100%. In one case self-limiting vasospasm was observed angiographically as a technique related complication in the animal model. Endovascular stentectomy using the SOS technique is feasible in an experimental setting and may be transferred to a clinical scenario.

  9. Permanent Pacemaker-Induced Superior Vena Cava Syndrome: Successful Treatment by Endovascular Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela; Carbonell, Miguel A.; Garcia, Lorenzo Garcia

    2003-01-01

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later

  10. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  11. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Lu Jun; Liu Jiachun; Wang Lijun; Qi Peng; Wang Daming

    2012-01-01

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  12. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  13. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  14. Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils in a canine model

    International Nuclear Information System (INIS)

    Liu Jianmin; Zhang Xin; Zhou Xiaoping; Hong Bo; Xu Yi; Huang Qinghai; Zhang Long; She Jiagui; Zhao Rui

    2004-01-01

    Objective: To assess hemodynamics and histology of the aneurysms by treating experimental wide-necked aneurysms endovascularly with a combination of stents and electrolytic detachable coils. Methods: An experimental model was surgically constructed in the necks of six canines for simulating intracranial wide-necked aneurysms. Balloon-expandable metal stents were positioned across the aneurysms in bilateral carotid arteries of six canines with additional intraaneurysmal placement of detachable microcoils in only unilateral carotid artery of each canine. Sonography and angiography were performed in different stages and histologic examinations were achieved finally. Results: Stent placement was successful in all six canines. Aneurysms treated with only stents placement showed no significant thrombus formation with slow growing of neointima over the neck of the aneurysm. Thrombosis occurred in the aneurysms treated with stents and coils in a short time and neointima covered the neck of the aneurysms completely. Conclusions: Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils may prevent re-rupture of the aneurysms and promote neointima formation over the neck of the aneurysms. (authors)

  15. Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents

    Science.gov (United States)

    Bowen, Patrick K.; Guillory, Roger J.; Shearier, Emily R.; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-01-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells. PMID:26249616

  16. Budd-Chiari syndrome due to prothrombotic disorder: mid-term patency and efficacy of endovascular stents

    Energy Technology Data Exchange (ETDEWEB)

    Pelage, Jean-Pierre; Denys, Alban; Sibert, Annie; Menu, Yves [Department of Radiology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Valla, Dominique [Department of Hepatology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Sauvanet, Alain; Belghiti, Jacques [Department of Surgery, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France)

    2003-02-01

    Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients. (orig.)

  17. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  18. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  19. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents

    International Nuclear Information System (INIS)

    Teichgräber, Ulf K.; Bucourt, Maximilian de

    2012-01-01

    Objectives: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). Materials and methods: The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. Results: The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. Conclusion: VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system.

  20. Bilateral spontaneous internal carotid artery dissection managed with endovascular stenting – A case report

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Agarwala

    2016-09-01

    We describe a patient with ischemic stroke from spontaneous bilateral ICAD with completely occluded left ICA. Having failed medical therapy with antiplatelets and anticoagulants due to extensive loss of carotid vascular supply, he was managed successfully with endovascular stenting with good neurological recovery.

  1. Adhesion and endothelialization of endothelial cells on the surface of endovascular stents by the novel rotational culture of cells

    International Nuclear Information System (INIS)

    Tang Chaojun; Wang Guixue; Cao Yi; Wu Xue; Xie Xiang; Xiao Li

    2008-01-01

    Recent researches indicate that the initial event in the implantation of endovascular stents involves mechanical injury to the vessel wall. Confluent endothelialization of vascular grafts in vitro before implantation has been suggested as a way to reduce injury of the blood vessel. The purpose of this study is to establish a useful way to improve the adhesion of endothelial cells and accelerate endothelialization on the surface of endovascular stents by a novel rotational culture device. Numerical simulation was used to predict the shear stress on the surface of stents. The number of cellular adhesion was calculated by cell counting, the cell growth was observed by scanning electron microscope and fluorescence microscope. Numerical simulation results showed that the stents was exposed to shear stress of 2.66 x 10 -3 to 8.88 x 10 -2 Pa. Rotational culture of human umbilical vein endothelial cells could enhance the adhesion of cells and accelerate endothelialization on the surface of stents when the culture conditions for EC adhesion were intermediate rotation speed, higher dynamic incubation times, lower cell densities

  2. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents.

    Science.gov (United States)

    Teichgräber, Ulf K; de Bucourt, Maximilian

    2012-01-01

    OJECTIVES: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  4. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  5. Treatment of portal hypertension caused by benign main portal vein stenosis with endovascular stent

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Guan Shouhai; Zhu Kangshun; Li Zhengran; Zhou Yubin; He Bingjun

    2004-01-01

    Objective: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Methods: Portal vein stents were implanted in 6 patients with benign main portal vein stenosis (inflammatory stenosis in 3 cases, postprocedure of liver transplantation in another 3 cases). The change of portal vein pressure, the patency of portal vein, relative clinical symptoms, complications, and survival were evaluated. Results: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in all 6 patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3 ± 4.7) cm H 2 O (1 cm H 2 O=0.098 kPa) to (18.0 ± 1.9) cm H 2 O (P<0.001). The portal blood flow was restored, and the symptoms caused by portal hypertension were eliminated. There was no severe procedure-related complication. Follow-up time was from 5 to 36 months. The portal vein remained patent during the follow-up. All patients survived except one patient who died of other complications of liver transplantation. Conclusion: Percutaneous portal vein stent placement for the treatment of the benign main portal vein stenosis is safe and effective. (authors)

  6. Endovascular repair of renal artery aneurysm with the multilayer stent – a short report

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2012-10-01

    in the main left renal artery involving all three major branches of the renal artery. Via a percutaneous femoral approach a multilayer stent was deployed without complications. Blood flow inside the sac was immediately and significantly reduced. All the renal branches remained patent. Conclusion: New multilayer fluid modulating stent concept appears to be a very useful and attractive alternative to surgery or other endovascular techniques for those RAA involving or very close to major branch vessels, especially in patients with very high risk of loosing the only viable kidney, as in our case.

  7. Assessment of effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion using self-expanding Jaguar SM stents

    International Nuclear Information System (INIS)

    Kordecki, Kazimierz; Łukasiewicz, Adam; Nowicki, Mirosław; Lewszuk, Andrzej; Kowalewski, Radosław; Panek, Bogusław; Zawadzki, Michał; Michalak, Paweł; Gacko, Marek; Łebkowska, Urszula

    2012-01-01

    The goal of this work was to assess the effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion classified according to TASC using a self-expanding stent Jaguar SM. The study group included 95 patients (61 men and 34 women) who underwent treatment for stenosis or occlusion of lower limb arteries at the Department of Radiology of the University Hospital in Bialystok and the Diagnostic Radiology Department of the Central Clinical Hospital of the Ministry of Interior (MSWiA) in Warsaw between 2005 and 2007. All arterial lesions were of atherosclerotic etiology. The shortest stenotic fragment was 10 mm long and the longest occluded arterial fragment did not exceed 90 mm. Morphological classification of iliac artery lesions in treated patients was performed according to TASC II classification and included 10 patients with type A, 39 cases of type B, 36 with type C and 10 patients with type D lesions. Endovascular procedure failed to restore flow in five patients with TASC type D lesions, who were later referred for surgery. One patient suffered a complication – vessel perforation during predilatation, and had a stentgraft implanted. In 95% of patients stents were expanded using a balloon after implantation. Good results were achieved in practically all patients who underwent stent implantation. Patients were subjected to follow-up clinical and imaging evaluation during next 1–24 months. Success rate of the performed procedures as well as in a 30-day observation period was 100% in case of stenosis and 80% in case of vessel occlusion. A follow-up after 12 and 24 months showed patency of treated vessels in 84% and 76% of patients, respectively

  8. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  9. Endovascular treatment of acutely ruptured, wide-necked anterior communicating artery aneurysms using the Enterprise stent.

    Science.gov (United States)

    Huang, Qing-Hai; Wu, Yong-Fa; Shen, Jie; Hong, Bo; Yang, Peng-Fei; Xu, Yi; Zhao, Wen-Yuan; Liu, Jian-Min

    2013-02-01

    The treatment of anterior communicating artery (AcomA) wide-necked aneurysms with the Enterprise stent (Codman, Miami Lakes, FL, USA) has not been commonly described, due to the complexity of the vascular anatomy and the small vessels of the AcomA complex. To evaluate the feasibility, effectiveness and safety of Enterprise stent placement in AcomA aneurysms, we performed this retrospective study. Between November 2008 and December 2010, 27 wide-necked AcomA ruptured aneurysms were treated within 72 hours of ictus with the Enterprise stent. Data collected and analyzed were: demographic data, morphologic features of the aneurysm, treatment results and follow-up results. Twenty-nine Enterprise stents were successfully deployed in all 27 aneurysms, including Y-configuration stent deployment in two patients. The initial embolization degrees were Raymond class I in 20 patients, class II in five and class III in the other two. The angiographic follow-up of 21 patients (mean, 8.4 months) showed that all aneurysms remained stable or improved; there was no in-stent stenosis, recurrence or retreatment. The clinical follow-up of 26 patients (mean, 12.6 months) showed that 23 patients displayed no symptoms and no or mild disability; three patients remained with severe or moderately severe disability. The Enterprise stent is feasible and safe for endovascular embolization of wide-necked AcomA ruptured aneurysms. Further follow up is needed to assess the long-term efficacy of Enterprise stent placement in AcomA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  11. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    Directory of Open Access Journals (Sweden)

    Bishu K

    2015-07-01

    Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture

  12. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  13. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  14. Management of Endovascular Aortic Aneurysm Complications via Retrograde Catheterization Through the Distal Stent-Graft Landing Zone.

    Science.gov (United States)

    Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao

    2017-08-01

    A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.

  15. Endovascular revascularization for aortoiliac atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Aggarwal V

    2016-03-01

    Full Text Available Vikas Aggarwal,1 Stephen W Waldo,2,3 Ehrin J Armstrong2,3 1Prairie Heart Institute, St John's Hospital, Springfield, IL, 2Section of Cardiology, Denver Veterans Affairs Medical Center, 3Section of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Atherosclerotic iliac artery disease is increasingly being treated with endovascular techniques. A number of new stent technologies can be utilized with high long-term patency, including self-expanding stents, balloon-expandable stents, and covered stents, but comparative data on these stent types and in more complex lesions are lacking. This article provides a review of currently available iliac stent technologies, as well as complex procedural aspects of iliac artery interventions, including approaches to the treatment of iliac bifurcation disease, long segment occlusions, choice of stent type, and treatment of iliac artery in-stent restenosis. Keywords: peripheral artery disease, iliac artery, balloon expandable stent, self expanding stent, covered stent, claudication, endovascular

  16. Endovascular treatment of nutcracker syndrome - a case report

    International Nuclear Information System (INIS)

    Rowinski, O.; Januszewicz, M.; Wojtaszek, M.; Nawrot, I.; Szmidt, J.

    2007-01-01

    The 'nutcracker' syndrome is most commonly caused by arterial compression of the left renal vein between the superior mesenteric artery and the aorta. As a consequence venous blood pressure increases within the renal pelvis, ureter and gonadal veins. This compression syndrome may be treated by endovascular stent implantation into the left renal vein. A 20 year old female patient was referred to us, suffering from pain in her left side, gross proteinuria and the suspicion of 'nutcracker' syndrome. Symptoms were present for the last 3 years. Angio MRI was performed and confirmed compression of the left renal vein between the aorta and the superior mesenteric artery. The patient was qualified for endovascular treatment. A self expandable metallic stent, diameter 16 x 40 mm was implanted into the left renal vein. Control venography confirmed good placement of the stent and a good immediate hemodynamic effect of the procedure. The patient remains symptom free in a 14 month follow up period. At present, endovascular stenting seems to be the method of choice for the treatment of the nutcracker syndrome. (author)

  17. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  18. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  19. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    NARCIS (Netherlands)

    Onuta, Geanina; Groenewegen, Hendrik C.; Klatter, Flip A.; Boer, Mark Walther; Goris, Maaike; van Goor, Harry; Roks, Anton J. M.; Rozing, Jan; de Smet, Bart J. G. L.; Hillebrands, Jan-Luuk

    2011-01-01

    Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on development of

  20. Long-term type 1 diabetes enhances in-stent restenosis after aortic stenting in diabetes-prone BB rats

    NARCIS (Netherlands)

    J.-L. Hillebrands (Jan-Luuk); G. Onuta (Geanina); H.C. Groenewegen (Hendrik); F.A. Klatter (Flip); M. Walther Boer (Mark); M. Goris (Maaike); H. van Goor (Harry); A.J.M. Roks (Anton); J. Rozing (Jan); B.J.G.L. de Smet (Bart)

    2011-01-01

    textabstractType 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on

  1. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  2. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  3. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Prabhudesai, V.; Mitra, K.; West, D. J.; Dean, M. R. E.

    2003-01-01

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome

  4. A Case of Pseudoaneurysm of the Internal Carotid Artery Following Endoscopic Endonasal Pituitary Surgery: Endovascular Treatment with Flow-Diverting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali Karadag

    2017-10-01

    Full Text Available Internal carotid artery (ICA pseudoaneurysm is a rare complication of endoscopic endonasal surgery occurring in 0.4–1.1% of cases. Pseudoaneurysms can subsequently result in other complications, such as subarachnoid hemorrhage, epistaxis, and caroticocavernous fistula with resultant death or permanent neurologic deficit. In this case, we illustrate endovascular treatment with a flow-diverting stent for an ICA pseudoaneurysm after endoscopic endonasal surgery for a pituitary adenoma in a 56-year-old male. Surgery was complicated by excessive intraoperative bleeding and emergent CT angiography confirmed an iatrogenic pseudoaneurysm on the anteromedial surface of the ICA. The pseudoaneurysm was treated endovascularly with flow-diverting stent implantation only. Follow-up CT angiography after three months demonstrated occlusion of the pseudoaneurysm.

  5. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  6. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  7. Endovascular Treatment of Dialysis Access-Induced Hand Ischemia Using a Flared Stent-Graft.

    Science.gov (United States)

    Png, Chien Yi M; Beckerman, William E; Faries, Peter L; Finlay, David J

    2017-10-01

    To report an investigation of a purely endovascular procedure to address access-induced hand ischemia in dialysis patients. Two dialysis patients presented with stage III steal syndrome consisting of severe pain and numbness in their fingers. Preoperative fistulograms distal to the anastomosis showed alternating antegrade and retrograde flow. Under ultrasound guidance, the fistula was accessed and a 4-F micropuncture sheath placed. An angled guidewire was then advanced proximally into the brachial artery. A 6-F short sheath with marker was placed followed by a 4-F straight guide catheter inserted into the proximal brachial artery. A 9-F Flair endovascular stent-graft was advanced over a 0.035-inch stiff angled Glidewire into the fistula just distal to the arterial anastomosis and deployed. Postoperatively, pain and numbness resolved in both patients immediately. Postoperative fistulograms documented antegrade flow. Access flow velocity readings decreased significantly and pulse oximetry readings increased significantly in both patients, who were followed for >6 months with no reported complications. These 2 cases suggest that this endovascular approach to access-induced hand ischemia may be a viable alternative to open/hybrid surgery.

  8. A Phase II study of external-beam radiotherapy and endovascular brachytherapy with PTA and stenting for femoropopliteal artery restenosis

    International Nuclear Information System (INIS)

    Narayan, Kailash; Denton, Michael; Das, Ram; Bernshaw, David; Rolfo, Aldo; Dyk, Sylvia van; Mirakian, Alex

    2006-01-01

    Purpose: To assess the safety and seek evidence of efficacy of combined external-beam radiotherapy (EBRT) and endovascular brachytherapy in the treatment of stenotic vascular lesions. Methods and Materials: Seventeen patients with high risk for restenosis of femoropopliteal arteries were enrolled in this study from February 2000 to August 2002. The external beam radiotherapy regimen consisted of 10 Gy in 5 fractions of 2 Gy, starting on Day 0. This was followed on Day 6 by angiography, stent placement, and intraluminal brachytherapy to a dose of 10 Gy at 1.2 mm from stent surface. The EBRT was continued from the same day to another 10 Gy in 2 Gy daily fractions for 5 days. Results: The follow up ranged from 33 months to 60 months. At the time of analysis 15 of 17 patients were alive with patent stents. Of these, 10 were symptom-free. Two patients died of unrelated causes. Conclusions: The combination of EBRT and endovascular brachytherapy provided adequate dose distribution without any geographical miss or 'candy wrapper' restenosis. No incidence of aneurysmal dilation of radiated vascular segment was observed. The treatment was feasible, well tolerated, and achieved 88% stenosis free survival

  9. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  10. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  11. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  12. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  13. Endovascular stent-graft placement for the treatment of acute onset and chronic aortic dissections of the descending aorta (Short-term follow-up)

    International Nuclear Information System (INIS)

    Petrov, I; Jorgova, J.; Trendafilova, D.

    2004-01-01

    The leading cause of death for patients with surgically untreated thoracic aortic aneurysms is the rupture of the aneurysm. Almost one half of these patients are left to medical treatment assuming the risk of late rupture and aneurysm sac enlargement - the late surgical treatment of these patients is too risky and with poor results. On the other hand the emergent surgical treatment of these cases is related with relatively high mortality rate. Recently, thoracic aortic stent-grafting has emerged as a less traumatic alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. The first case of stent implantation in a dissected descending aorta was performed in Bulgaria at 09.04.2003. Since then we implanted in 8 patients thoracic stent grafts, The mean age of the patients was 67.5 years. The primary success was 100%. One died on the second postoperative day by abdominal aorta rupture. No other complications were registered. The mean follow-up of 5 months proved to be uneventful and the control CT revealed efficacious sealing of the entry and false lumen thrombosis in all except one cases. We report our initial clinical experience of endovascular stent-graft repair for dissection of the descending aorta that is encouraging. These preliminary data suggest that endovascular stent-grafting is a viable treatment for acute onset and chronic aortic dissection type B

  14. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  15. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  16. Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Eric J.; Collins, Jeremy D. [Northwestern University Feinberg School of Medicine, Department of Radiology (United States); Crowley-Matoka, Megan [Northwestern University Feinberg School of Medicine, Center for Bioethics and Medical Humanities (United States); Chrisman, Howard B. [Northwestern University Feinberg School of Medicine, Department of Radiology (United States); Milad, Magdy P. [Northwestern University Feinberg School of Medicine, Department of Obstetrics and Gynecology-Reproductive Endocrinology and Infertility (United States); Vogelzang, Robert L., E-mail: vogelzang@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology (United States)

    2017-06-15

    PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

  17. Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

    International Nuclear Information System (INIS)

    Keller, Eric J.; Collins, Jeremy D.; Crowley-Matoka, Megan; Chrisman, Howard B.; Milad, Magdy P.; Vogelzang, Robert L.

    2017-01-01

    PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

  18. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  19. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de medecine interne, Pole Pluridisciplinaire de Medecine (France); Thony, Frederic, E-mail: FThony@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de reanimation, Pole Medecine Aiguee Communautaire (France); Rodiere, Mathieu, E-mail: MRodiere@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Monnin-Bares, Valerie, E-mail: v-monnin@chu-montpellier.fr [CHRU Arnaud de Villeneuve, Imagerie Medicale Thoracique Cardiovasculaire (France); Ferretti, Gilbert R., E-mail: GFerretti@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Vesin, Aurelien; Moro-Sibilot, Denis, E-mail: DMoro.pneumo@chu-grenoble.fr [University Grenoble 1 e Albert Bonniot Institute, Inserm U823 (France)

    2013-02-15

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  20. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    International Nuclear Information System (INIS)

    Fagedet, Dorothée; Thony, Frederic; Timsit, Jean-François; Rodiere, Mathieu; Monnin-Bares, Valérie; Ferretti, Gilbert R.; Vesin, Aurélien; Moro-Sibilot, Denis

    2013-01-01

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  1. Hybrid endovascular stent-grafting technique for patent ductus arteriosus in an adult.

    Science.gov (United States)

    Kainuma, S; Kuratani, T; Sawa, Y

    2011-09-01

    A 51-year-old man was referred to our institution for patent ductus arteriosus (PDA) complicated by left ventricular dysfunction and pulmonary hypertension. Surgical closure of a PDA is usually carried out via a small posterior thoracotomy. However, thoracoscopic procedures are probably not appropriate in adults because of the frequency of calcification and the greater risk of rupture while ligating the ductus. To minimize surgical trauma, we used hybrid endovascular stent grafting combined with revascularization of the left subclavian artery, which enabled us to eliminate shunt flow to the pulmonary artery. At 11-month follow-up, the patient was asymptomatic and showed no complications. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Stenting of the SFA - indications, techniques,

    International Nuclear Information System (INIS)

    Rieger, J.; Treitl, M.; Reiser, M.; Ruppert, V.

    2006-01-01

    Aggressive risk factor modification, change of eating habits, exercise programs, and forceful antiplatelet therapy are the most important tools for the treatment of PAOD in symptomatic patients suffering from intermittent claudication. There are however no guidelines for revascularization at this stage. Endovascular treatment has been increasingly utilized over the last decade and increasingly displaced vascular surgery. Amongst numerous endovascular techniques beside PTA, stents meanwhile play the most important role due to constant technical progress. Results regarding the rate of restenosis or patency rates still remain worse compared to other vascular beds. This paper gives a review over recent results, currently available stent techniques, and possible indications for the endovascular therapy of an artery, which has turned out to be the biggest ordeal for material and construction of stents. (orig.) [de

  3. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  4. MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting

    International Nuclear Information System (INIS)

    Clarke, M.G.; Thomas, H.G.; Chester, J.F.

    2005-01-01

    A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm

  5. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  6. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  7. Endovascular treatment with a stent-graft for internal carotid artery laceration during trans sphenoidal surgery: a case report

    International Nuclear Information System (INIS)

    Choe, Eun Hwa; Ko, Ji Ho; Lee, Tae Hong; Rho, Myung Ho

    2008-01-01

    An internal carotid artery (ICA) tear during or after trans-sphenoidal surgery (TSS) is rare but may cause potentially lethal complications. A 23-year-old female patient visited our hospital for treatment of a Rathke's cleft cyst. The patient had massive hemorrhage during surgery and angiography performed after surgery showed laceration of the cavernous ICA. We successfully controlled the hemorrhage with emergency placement of an endovascular stent-graft

  8. Pseudoaneurisme på arteria carotis interna behandlet med stent

    DEFF Research Database (Denmark)

    Benian, Cemil; Wagner, Aase; Cortsen, Marie

    2013-01-01

    Extracranial internal carotid artery aneurysms (EACIAs) are rare. Untreated they have a high stroke rate. Traditionally the treatment has been surgery or endovascular intervention with coils. Both are associated with relatively high complication rates. Another treatment option is endovascular int...... intervention with covered stent, which provides one-step closure of the aneurysm. As in the case story it can be complicated with in-stent occlusion. Therefore we recommend balloon occlusion test before treatment of EACIAs with covered stent....

  9. Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang

    2010-01-01

    Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)

  10. Duplex evaluation following femoropopliteal angioplasty and stenting: criteria and utility of surveillance.

    Science.gov (United States)

    Baril, Donald T; Marone, Luke K

    2012-07-01

    Surveillance following lower extremity bypass, carotid endarterectomy, and endovascular aortic aneurysm repair has become the standard of care at most institutions. Conversely, surveillance following lower extremity endovascular interventions is performed somewhat sporadically in part because the duplex criteria for recurrent stenoses have been ill defined. It appears that duplex surveillance after peripheral endovascular interventions, as with conventional bypass, is beneficial in identifying recurrent lesions which may preclude failure and occlusion. In-stent stenosis following superficial femoral artery angioplasty and stenting can be predicted by both peak systolic velocity and velocity ratio data as measured by duplex ultrasound. Duplex criteria have been defined to determine both ≥50% in-stent stenosis and ≥80% in-stent stenosis. Although not yet well studied, it appears that applying these criteria during routine surveillance may assist in preventing failure of endovascular interventions.

  11. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  12. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  13. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    Science.gov (United States)

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  14. Endovascular treatment for extrahepatic portal vein bifurcation stenosis after a Whipple procedure using the kissing stents technique.

    Science.gov (United States)

    Zhang, Wen-guang; Liu, Dong-mei; Li, Zhen; Wang, Yan-Li; Ding, Peng-xu; Zhou, Peng-li; Wang, Zhong-gao; Han, Xin-wei

    2014-01-01

    A 57-year-old man presented with a rare extrahepatic portal vein bifurcation scar stenosis involving the proximal splenic vein and superior mesenteric vein after a Whipple procedure. He was treated with endovascular coil embolization for the gastroesophageal varices and kissing stents for the portal vein bifurcation stenosis. This case illustrates a rarely seen complication after the Whipple procedure and a novel management strategy that can be considered in the management of this complex disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    International Nuclear Information System (INIS)

    Wu, Tian-Tian; Li, Hu-Cheng; Zheng, Fang; Ao, Guo-Kun; Lin, Hu; Li, Wei-Min

    2016-01-01

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  16. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  17. Perioperative nursing for patients with diabetic foot receiving endovascular interventional therapy

    International Nuclear Information System (INIS)

    Yang Yang; Wang Feng; Li Ke; Li Cheng; Ji Donghua

    2010-01-01

    Objective: To study the effect of perioperative nursing on the living quality of patients with diabetic foot who are treated with endovascular interventional therapy. Methods: Specific perioperative nursing care plan was accordingly designed for 43 patients with diabetic foot. Endovascular balloon angioplasty and stent implantation were formed in these patients to treat their diabetic foot. The clinical results were observed. Results: Perioperative nursing effectively improved patient's limb blood supply, enhanced the healing of diabetic foot ulceration and increased the possibility of limb preservation. Conclusion: Endovascular therapy combined with corresponding perioperative nursing care can benefit more patients with diabetic foot. (authors)

  18. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  19. Stent tunnel technique to save thrombosed native hemodialysis fistula with extensive venous aneurysm

    Directory of Open Access Journals (Sweden)

    Rabellino M

    2017-07-01

    Full Text Available Martin Rabellino,1 Guillermo J Rosa-Diez,2 Sergio A Shinzato,1 Pablo Rodriguez,1 Oscar A Peralta,1 Maria S Crucelegui,2 Rosario Luxardo,2 Agustina Heredia-Martinez,2 Mariela I Bedini-Rocca,2 Ricardo D García-Mónaco1 1Department of Angiography and Endovascular Therapy, 2Department of Nephrology, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Introduction and purpose: The increasing number of patients undergoing hemodialysis and the limited number of access sites have resulted in an increasing number of techniques to maintain vascular access for hemodialysis. Thrombosed arteriovenous (AV fistulas with large venous aneurysms have poor treatment results, with both endovascular and surgical techniques, leading to a high rate of definitive AV access loss. The purpose of this study was to review the feasibility and initial results of this novel endovascular treatment of thrombosed AV fistulas with large venous aneurysms.Materials and methods: A novel endovascular treatment technique of inserting nitinol auto-expandable uncovered stents stretching through the whole puncture site area, thus creating a tunnel inside the thrombus, was retrospectively analyzed and described.Results: A total of 17 stents were placed in 10 hemodialysis fistulas, with a mean venous coverage length of 17.8 cm. In all the cases, 100% technical success was achieved, with complete restoration of blood flow in all patients. There were no procedure-related complications. The mean follow-up was 167 days (range 60–420 days, with a primary and assisted patency of 80% and 100%, respectively. No multiple trans-stent struts-related complications were observed. Three stent fractures were diagnosed with plain films at the site of puncture without consequence in the venous access permeability.Conclusion: The “stent tunnel technique” is a feasible, safe and effective alternative to salvage native hemodialysis access, thus extending the function of the venous access with

  20. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  1. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  2. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-09-20

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  3. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Leto, John; George, Christopher; Van Epps, Kelly; Woeste, Troy; Berlet, Mathew

    2008-01-01

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus

  4. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  5. Multimodal Therapy for the Treatment of Severe Ischemic Stroke Combining Endovascular Embolectomy and Stenting of Long Intracranial Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Matjaž Bunc

    2010-01-01

    Case Report. We present a case of a 49-year-old female patient who—according to the National Institute of Health Stroke Scale (NIHSS—was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA. After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach—without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA.

  6. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  7. Correção endovascular de persistência do conduto arterioso em paciente adulto Endovascular approach for persistent ductus arteriosus closure in adult patient

    Directory of Open Access Journals (Sweden)

    José Carlos Dorsa Vieira Pontes

    2010-03-01

    Full Text Available O tratamento da Persistência do Canal Arterial (PCA, em adultos, ainda é controverso. A utilização de próteses auto-expansíveis tem-se mostrado como uma alternativa eficaz ao tratamento cirúrgico. Apresentamos um caso de uma paciente de 45 anos submetida ao tratamento endovascular com o uso de stent auto-expansível.The treatment for closure of persistent ductus arteriosus (PDA in adults still controversial. The endovascular approach has been shown as an effective alternative to surgical treatment. We report a case of 45 years old pacient submitted to endovascular approach for PDA closure.

  8. Mechanical thrombectomy using Rotarex system and stent-in-stent placement for treatment of distal femoral artery occlusion secondary to stent fracture – a case report and literature review

    International Nuclear Information System (INIS)

    Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech

    2013-01-01

    Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients

  9. Evaluation of the efficacy and safety of endovascular management for transplant renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Leonardo G.M. Valle

    Full Text Available OBJECTIVES: To evaluate the safety and efficacy of endovascular intervention with angioplasty and stent placement in patients with transplant renal artery stenosis. METHODS: All patients diagnosed with transplant renal artery stenosis and graft dysfunction or resistant systemic hypertension who underwent endovascular treatment with stenting from February 2011 to April 2016 were included in this study. The primary endpoint was clinical success, and the secondary endpoints were technical success, complication rate and stent patency. RESULTS: Twenty-four patients with transplant renal artery stenosis underwent endovascular treatment, and three of them required reinterventions, resulting in a total of 27 procedures. The clinical success rate was 100%. All graft dysfunction patients showed decreased serum creatinine levels and improved estimated glomerular filtration rates and creatinine levels. Patients with high blood pressure also showed improved control of systemic blood pressure and decreased use of antihypertensive drugs. The technical success rate of the procedure was 97%. Primary patency and assisted primary patency rates at one year were 90.5% and 100%, respectively. The mean follow-up time of patients was 794.04 days after angioplasty. CONCLUSION: Angioplasty with stent placement for the treatment of transplant renal artery stenosis is a safe and effective technique with good results in both the short and long term.

  10. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    Directory of Open Access Journals (Sweden)

    Geanina Onuta

    2011-01-01

    Full Text Available Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s of long-term autoimmune diabetes on development of in-stent restenosis. We here describe the development of in-stent restenosis in long-term (~7 months spontaneously diabetic and age-matched, thymectomized, nondiabetic Diabetes Prone BioBreeding (BBDP rats (n=6-7 in each group. Diabetes was suboptimally treated with insulin and was characterized by significant hyperglycaemia, polyuria, proteinuria, and increased HbA1c levels. Stented abdominal aortas were harvested 28 days after stenting. Computerized morphometric analysis revealed significantly increased neointima formation in long-term diabetic rats compared with nondiabetic controls. In conclusion, long-term autoimmune diabetes in BBDP rats enhances in-stent restenosis. This model can be used to study the underlying pathogenetic mechanisms of diabetes-enhanced in-stent restenosis as well as to test new therapeutic modalities.

  11. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  12. Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection.

    Science.gov (United States)

    Qing, K-X; Chan, Y-C; Ting, A C W; Cheng, S W K

    2016-05-01

    Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Endovascular thrombectomy for M2 occlusions: comparison between forced arterial suction thrombectomy and stent retriever thrombectomy.

    Science.gov (United States)

    Kim, Yong-Won; Son, Seungnam; Kang, Dong-Hun; Hwang, Yang-Ha; Kim, Yong-Sun

    2017-07-01

    To date there has been no direct comparison of two frequently used endovascular thrombectomy (EVT) methods (forced arterial suction thrombectomy (FAST) and stent retriever thrombectomy) in M2 occlusions. We review our experiences with EVT performed using FAST and stent retriever thrombectomy in such cases. The subjects comprised 41 patients with an M2 occlusion who underwent EVT (25 with FAST, 16 with stent retriever thrombectomy). The patients' data were retrospectively analyzed to evaluate the technical characteristics and angiographic outcome of the two EVT techniques. Thrombolysis In Cerebral Infarction (TICI) grades 2b-3 using the first chosen technique did not differ significantly between the two techniques (FAST 64.0% vs stent retriever thrombectomy 81.2%, p=0.305). Time from groin puncture to reperfusion was significantly shorter for stent retriever thrombectomy (53.0 vs 38.5 min; p=0.045). Distal embolization occurred in three cases (12.0%) in the FAST group and in four (26.7%) in the stent retriever group (p=0.362). However, the two techniques did not differ significantly in the final TICI 2b-3 rate (72.0% vs 87.5%; p=0.441). A frequent angiographic finding regarding the failure of FAST was that the M2 occlusion was located immediately after severe acute angulation between M1 and M2. Stent retriever thrombectomy may provide faster reperfusion than FAST, while the FAST technique might be associated with lower distal embolization and a higher reperfusion rate for the first thrombectomy attempt, but without any significant difference in clinical outcome. When choosing the EVT method for M2 occlusions, consideration of the location of the occlusion and tortuosity between M1 and M2 might be helpful to achieve a better angiographic outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Nursing experience in clinical endovascular treatment for renal artery aneurysms

    International Nuclear Information System (INIS)

    Dong Yanfen; Pan Xiaoxia; Luan Shaoliang; Wei Ren

    2012-01-01

    Objective: To discuss the standardized clinical nursing measures for patients receiving endovascular treatment of renal artery aneurysms. Methods: The clinical data of 9 patients with renal artery aneurysm, who were admitted to authors' hospital during the period from Jan. 2010 to Aug. 2011 and received endovascular treatment, were retrospectively analyzed. The related nursing points as well as the received endovascular. Results: A total of 9 cases with renal artery aneurysm were treated nursing measures were summarized. Results: A total of 9 cases with renal artery aneurysm were with interventional management, including embolization (n = 6), stent implantation (n = 2) and stent implantation together with coil embolization (n = 1). The mean hospitalization time was (10±2) days. Postoperative retention of urine was observed in one patient and postoperative retroperitoneal hemorrhage occurred in another patient. Neither nursing-related nor operation-related complications occurred. Conclusion: Standardized perioperative nursing care for patients with renal artery aneurysm can surely help enhance the patient's tolerance to the surgery, and effectively prevent the complications. (authors)

  15. Intestinal infarction: A complication of endovascular therapy

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; Sukumar, Sathi; Thompson, David; Roulson, Jo-An; Pritchard, Susan; Ashleigh, Raymond J.

    2007-01-01

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain

  16. Intestinal infarction: A complication of endovascular therapy

    Energy Technology Data Exchange (ETDEWEB)

    England, Andrew [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)]. E-mail: andrew.england@smtr.nhs.uk; Butterfield, John S. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Sukumar, Sathi [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Thompson, David [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Roulson, Jo-An [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Pritchard, Susan [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Ashleigh, Raymond J. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)

    2007-08-15

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain.

  17. Endovascular treatment for arterial injuries of skull base

    International Nuclear Information System (INIS)

    Li Tianxiao; Bai Weixing; Zai Suiting; Wang Ziliang; Xue Jiangyu

    2008-01-01

    Objective: To explore the role of endovascular techniques in treatment for arterial injuries of skull base. Methods: A total of 53 consecutive cases suffered from skull base arterial injuries were enrolled in our hospital from Oct 2004 to May 2007, including 44 male and 9 female cases with average age of 23.3 years. Thirty-nine cases presented with pulsatile exophthalmos and intracranial vascular murmur, cerchnus and dysphagia in another 9, epistaxis in the remaining 5 cases. Diagnosis of 39 carotid cavernous fistulae (CCF)and 14 carotid pseudoaneurysm were performed by angiography (DSA). Alternative endovascular procedures were performed depending on lesions characteristics and follow-up was done by telephone and outpatient work up. Results: Procedures were performed involving 56 carotid arteries in all 53 cases including 34 CCF with embolization of detachable balloon(33 cases), 3 with balloon and coils, and 3 by stent-graft placement. 8 carotid pseudoaneurysms were cured by parent artery occlusion with balloon, 2 experienced endovascular isolation with balloon and coils, and 4 with stent-graft. Follow-up for mean 9.5 months (range from 2 to 25 months) revealed that the chief symptoms of 45 cases (85%) were relieved within 6 months after the procedure but ocular movement and visual disorder remained in 8 cases (15%)till 12 months. Six pseudoaneurysms and 3 residual leak were found in reexamination, of which 2 cases underwent intervention again 2 and 3 months later due to dural arterial-venous fistula in cavernous sinus, respectively. Conclusions: Endovascular treatment is safe and effective therapeutic option with minimal invasion for skull base arterial injuries. Detachable balloon embolization is the first choice for CCF and carotid pseudoaneurysm. Spring coil packing and stent-graft implantation should be in alternation as combination for special cases. (authors)

  18. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  19. A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

    International Nuclear Information System (INIS)

    Rivolta, Nicola; Fontana, Federico; Piffaretti, Gabriele; Tozzi, Matteo; Carrafiello, Gianpaolo

    2010-01-01

    We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

  20. Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies

    International Nuclear Information System (INIS)

    Pitton, M. B.; Herber, S.; Schmiedt, W.; Neufang, A.; Dorweiler, B.; Dueber, C.

    2008-01-01

    satisfactory follow-up despite the necessity for reintervention and graft extension in 3 of 6 cases (50%). Two patients with type B dissection died due to mesenteric ischemia despite sufficient mesenteric blood flow being restored (but too late). Two suffered from neurologic complications, 1 from paraplegia and 1 from cerebral ischemia (probably embolic), 1 from penetrating ulcer, and 1 from persistent ischemia of the kidney. Five of 9 (56%) patients with symptomatic thoracic aneurysm demonstrated endoleaks during follow-up and there was an increase in the aneurysm in 1. Conclusion. Endovascular treatment is safe and effective for emergency treatment of life-threatening acute thoracic aortic syndromes. Results are encouraging, particularly for traumatic aortic ruptures. However, regular follow-up is mandatory, particularly in the other pathologies, to identify late complications of the stent-graft and to perform appropriate additional corrections as required

  1. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... measurements, Mann-Whitney U test could discriminate between experts and novices (p = .002), between experts and intermediates (p = .010), and between novices and intermediates (p = .036). In stent selection the experts performed significantly better than both the novices and the intermediates (p = .002 and p...... of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and certification of future endovascular specialists....

  2. Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Zeebregts, Clark J.; Vourliotakis, George; Bekkema, Foppe; van den Dungen, Jan J. A. M.; Prins, Ted R.; Verhoeven, Eric L. G.

    Objective: During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes the incidence and origin of stein graft fractures after endovascular repair, its impact on patency, and strategies to prevent fractures.

  3. Simulative study on dose distribution of 103Pd stent in blood-vessel

    International Nuclear Information System (INIS)

    Yuan Shuyu; Dai Guangfu; Xu Zhiyong; Sun Fuyin; Xu Shuhe; Ma Fengwu

    2003-01-01

    Objective: To evaluate the dose distribution of 103 Pd stent in the blood-vessel. Methods: Simulative study on dose distribution of endovascular 103 Pd stent was conducted with thermoluminescence dosimeter. The vessel wall was substituted by muscle equivalent material in this simulative study. Results: When radioactivity of the study 103 Pd stent was 9.8 MBq the absorbed dose from the stent surface by muscle equivalent material was 9.8 Gy at 17 d (the half-life period of 103 Pd). The radioactivity of 103 Pd stent surface rapidly attenuated over the radial distance. 80% of the radioactivity at the area that was radially 0.4 mm apart from the stent surface was absorbed by the simulative blood-vessel wall. Conclusion: Endovascular 103 Pd stent does not exert significant injury on the surrounding organs or tissues

  4. Statistical parametric mapping and statistical probabilistic anatomical mapping analyses of basal/acetazolamide Tc-99m ECD brain SPECT for efficacy assessment of endovascular stent placement for middle cerebral artery stenosis

    International Nuclear Information System (INIS)

    Lee, Tae-Hong; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Kim, Dong-Soo; Park, Kyung-Pil

    2007-01-01

    Statistical parametric mapping (SPM) and statistical probabilistic anatomical mapping (SPAM) were applied to basal/acetazolamide Tc-99m ECD brain perfusion SPECT images in patients with middle cerebral artery (MCA) stenosis to assess the efficacy of endovascular stenting of the MCA. Enrolled in the study were 11 patients (8 men and 3 women, mean age 54.2 ± 6.2 years) who had undergone endovascular stent placement for MCA stenosis. Using SPM and SPAM analyses, we compared the number of significant voxels and cerebral counts in basal and acetazolamide SPECT images before and after stenting, and assessed the perfusion changes and cerebral vascular reserve index (CVRI). The numbers of hypoperfusion voxels in SPECT images were decreased from 10,083 ± 8,326 to 4,531 ± 5,091 in basal images (P 0.0317) and from 13,398 ± 14,222 to 7,699 ± 10,199 in acetazolamide images (P = 0.0142) after MCA stenting. On SPAM analysis, the increases in cerebral counts were significant in acetazolamide images (90.9 ± 2.2 to 93.5 ± 2.3, P = 0.0098) but not in basal images (91 ± 2.7 to 92 ± 2.6, P = 0.1602). The CVRI also showed a statistically significant increase from before stenting (median 0.32; 95% CI -2.19-2.37) to after stenting (median 1.59; 95% CI -0.85-4.16; P = 0.0068). This study revealed the usefulness of voxel-based analysis of basal/acetazolamide brain perfusion SPECT after MCA stent placement. This study showed that SPM and SPAM analyses of basal/acetazolamide Tc-99m brain SPECT could be used to evaluate the short-term hemodynamic efficacy of successful MCA stent placement. (orig.)

  5. Biomedical engineering in design and application of nitinol stents with shape memory effect

    Science.gov (United States)

    Ryklina, E. P.; Khmelevskaya, I. Y.; Morozova, Tamara V.; Prokoshkin, S. D.

    1996-04-01

    Our studies in the field of endosurgery in collaboration with the physicians of the National Research Center of Surgery of the Academy of Medical Sciences are carried out beginning in 1983. These studies laid the foundation for the new direction of X-ray surgery--X-ray Nitinol stenting of vessels and tubular structures. X-ray nitinol stents are unique self-fixing shells based on the shape memory effect and superelasticity of nickel-titanium alloys self- reconstructed under human body temperature. Applied for stenting of arteries in cases of stenosis etc., bile ducts in cases of benign and malignant stenoses, digestive tract in cases of oesophageal cancer and cervical canal uterus in cases of postsurgical atresiss and strictures of uterine. The purpose of stenting is restoration of the shape of artery or tubular structure by a cylinder frame formation. The especially elaborated original method of stenting allows to avoid the traditional surgical operation, i.e. the stenting is performed without blood, narcosis and surgical knife. The stent to be implanted is transported into the affected zone through the puncture under the X-ray control. Clinical applications of X-ray endovascular stenting has been started in March 1984. During this period nearly 400 operations on stenting have been performed on femoral, iliac, brachio-cephalic, subclavian arteries, bile ducts, tracheas, digestive tract and cervical canal uterus.

  6. Endovascular treatment of three traumatic lesions of the vertebral artery

    International Nuclear Information System (INIS)

    Galvis, Victor Raul; Medina V, Francisco Jose

    2007-01-01

    The purpose is to expose the results of the endovascular treatment of three traumatic lesions of the vertebral artery. Methods: in the period from October 2005 to May 2006, three patients with traumatic lesions in the vertebral artery were treated by endovascular therapy with an age average of 32 years. All the procedures were carried out using subtraction digital angiography under anesthesiology supervision and were started with a 5,000 IU heparin bolus, previous antiplatelet medication with clopidogrel. For the treatment of the lesions covered stents and coils were used. results: there were three documented cases of traumatic lesions of the vertebral artery treated by endovascular therapy, in two cases arteriovenous fistulas were identified (between vertebral artery and internal jugular vein) with associated pseudo aneurysms, and in one case a pseudo aneurysm without fistula was found. The first patient was treated with placement of a covered stent, in a second patient the lesion was occluded with coils and a third patient required stent and coils with satisfactory repair of the lesions. Complications were not presented as a result of the procedures. Conclusions: the endovascular treatment for traumatic lesions of the vertebral artery is an alternative with minimum morbidity and reasonable costs avoiding the open surgery and conserving the permeability of the vessel when it is possible

  7. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  8. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  9. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  10. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    Science.gov (United States)

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  12. The risk of endoleak following stent covering of the internal iliac artery during endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.

    2014-01-01

    Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views

  13. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  14. Management of stenosis lesions during the period of endovascular treatment for acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Hong-xing HAN

    2017-11-01

    Full Text Available Objective To investigate the management of stenosis lesions during endovascular treatment for acute ischemic stroke. Methods A total of 36 acute ischemic stroke patients combined with intracranial/extracranial arterial stenosis were treated with endovascular treatment or bridging treatment. Time from aggravation on admission or in hospital stay to femoral artery puncture, from femoral arterypuncture to recanalization were recorded. Modified Thrombolysis in Cerebral Infarction (mTICI was usedto assess the recanalization immediately after operation. Modified Rankin Scale (mRS was used to evaluate prognosis at 90 d after operation. Occurrence rate of symptomatic intracranial hemorrhage and mortality were recorded. Results Among 36 patients, 13 patients (36.11% underwent intravenous thrombolysis and then endovascular thrombectomy. In all patients, there were 21 (58.33% with intracranial stenosis and 15 (41.67% with extracranial stenosis, 16 (44.44% with anterior circulation stenosis and 20 (55.56% with posterior circulation stenosis. Stent thrombectomy was used in 25 patients (69.44% , while balloon dilatation and/or stent implantation was used in 11 patients (30.56% . For 21 patients with intracranial arterial stenosis, 4 were treated with balloon dilatation only, 9 with Wingspan self-expandable stents and 8 with Apollo balloon-expandable stents. Fifteen patients with extracranial arterial stenosis were treated with balloon dilatation and stent implantation. A total of 33 patients (91.67% achieved recanalization (mTICI 2b-3 grade, 21 patients (58.33% had good outcomes (mRS ≤ 2 score, while symptomatic intracranial hemorrhage occurred in 2 patients (5.56% and 5 (13.89% died. There were no statistically significant differences in the rate of good prognosis, symptomatic intracranial hemorrhage and mortality between intracranial and extracranial arterial stenosis, anterior and posterior circulation stenosis (Fisher exact probability: P > 0.05, for

  15. Tratamento endovascular de ruptura traumática da aorta torácica descendente Endovascular treatment of traumatic descending thoracic aortic rupture

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-06-01

    Full Text Available Paciente do sexo feminino, 55 anos de idade, vítima de atropelamento, foi admitida em unidade de emergência, onde se realizou o diagnóstico clínico, radiológico e tomográfico de ruptura traumática da aorta torácica descendente. Diante do achado, a paciente foi encaminhada para tratamento endovascular com colocação de endoprótese auto-expansível (stent pela artéria femoral. O tratamento obteve sucesso, evidenciado pela exclusão da lesão localizada previamente no istmo aórtico. O tratamento endovascular tem sido indicado nas afecções de aorta torácica descendente com bons resultados iniciais. Na ruptura traumática de aorta, a terapêutica endovascular representa uma alternativa aceitável, especialmente devido aos riscos do tratamento operatório convencional.A 55-year-old, female patient who was run over by a motor vehicle was admitted at an emergency room. Clinical, radiological and tomographic diagnosis of traumatic descending aortic thoracic rupture was performed. The patient was referred for endovascular treatment with placement of a self-expandable stent through the femoral artery. Treatment was successful, with exclusion of the lesion previously located in the aortic isthmus. Endovascular treatment has been indicated in the treatment of descending thoracic aortic diseases, with good initial results. In case of traumatic aortic rupture, endovascular treatment is a feasible alternative, especially due to risks offered by the conventional surgical treatment.

  16. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  17. Advances in endovascular therapy for ischemic cerebrovascular diseases

    Directory of Open Access Journals (Sweden)

    Jun Lu

    2016-09-01

    Full Text Available Endovascular therapy for ischemic cerebrovascular diseases has developed rapidly in recent years. The latest clinical trials of acute ischemic stroke have shown promising results with the continued advancement of concepts, techniques, and materials. Mechanical thrombectomy is recommended in the treatment of acute ischemic stroke caused by large vessel occlusion of the anterior circulation, according to the guidelines updated in Europe, USA, and China. The long-term therapeutic efficacy of endovascular stenting for carotid artery stenosis has also been proved noninferior to that of carotid endarterectomy. However, the latest clinical trials have shown that the efficacy of stenting for intracranial artery and vertebral artery stenosis is inferior to that of medical treatment alone, which needs urgent attention through further development and studies. Keywords: Ischemic cerebrovascular diseases, Interventional surgery, Progress

  18. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease

    NARCIS (Netherlands)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes Thomas; Sun, Chao; Slump, Cornelis H.; Goverde, Peter C.J.M.; Versluis, Michel; Reijnen, Michel M.P.J.

    Background Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry

  19. [Endovascular surgery in the war].

    Science.gov (United States)

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  20. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  2. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  3. Long term results of kissing stents in the aortic bifurcation

    NARCIS (Netherlands)

    Hinnen, J.W.; Konickx, M.A.; Meerwaldt, Robbert; Kolkert, J.L.P.; van der Palen, Jacobus Adrianus Maria; Huisman, A.B.

    2015-01-01

    BACKGROUND: To evaluate the long-term outcome after aortoiliac kissing stent placement and to analyze variables, which potentially influence the outcome of endovascular reconstruction of the aortic bifurcation. METHODS: All patients treated with aortoiliac kissing stents at our institution between

  4. Endovascular surgery in Marfan syndrome: CON.

    Science.gov (United States)

    Kouchoukos, Nicholas T

    2017-11-01

    The frequency of endovascular stent grafting procedures to treat various conditions of the thoracic aorta has increased dramatically over the past three decades. Stent grafting has been applied on a limited basis in patients with Marfan syndrome and other connective tissue disorders, despite recommendations from current guidelines and expert consensus statements against its use in this setting. A review of publications reporting outcomes after stent grafting of the descending thoracic aorta in Marfan patients with acute or chronic aortic dissection indicates that these procedures can be accomplished with rates of early mortality, stroke and spinal cord ischemic injury that are comparable to those observed in patients who do not have Marfan syndrome. However, the rates of primary treatment failure (principally endoleak), secondary treatment failure, need for open repair and late death among the Marfan patients are substantially higher than those observed in patients without this condition. In addition, the rates of retrograde aortic dissection and development of stent-graft induced new entry (SINE), are also greater among patients with Marfan syndrome. All of these findings argue strongly against the routine use of endovascular grafts in Marfan patients with type B or residual type A dissection. Few data are available to assess the role of endografting in Marfan patients with aneurysmal disease, but the progressive aortic dilatation noted in these patients argues strongly against its use in this setting as well. At present, the available data indicate that there is no justification for elective stent grafting in Marfan patients with aortic dissection or aneurysm. The only reasonable indications for primary aortic stent grafting are in the setting of acute aortic dissection or rupture, where the intervention is considered life-saving and rarely, considering the relatively young age of these patients, where the risk of open operation is considered to be prohibitive.

  5. Endovascular stent-support angioplasty for cerebral venous sinus stenosis

    Directory of Open Access Journals (Sweden)

    Xin-feng LI

    2011-06-01

    Full Text Available Objective To investigate the pathophysiological features of cerebral venous sinus stenosis,and the modus and therapeutic effect of stent-support angioplasty.Methods The clinical data of 36 patients with cerebral venous sinus stenosis,admitted to Neurosurgical Department of General Hospital of PLA from Dec.2001 to Jun.2010,were retrospectively analyzed.Of the 36 cases,10 were males and 26 females,aged from 14 to 57 years with a mean of 37.8 years,and the disease course ranged from 4 days to 9 years.The main clinical manifestations included headache,vomiting,optical visual blurring,and limb weakness with anesthesia in some patients.The diagnosis of all patients was confirmed by digital subtraction angiography,and the results showed that the local stenosis located in right transverse-sigmoid sinus in 21 cases,left transverse-sigmoid sinus in 12 cases,and on both sides in 3 cases.All patients received thrombolytic therapy via carotid artery or a microcatheter inserted in the venous sinus,followed by stent angioplasty of venous sinus.Meanwhile,general anticoagulant and antiplatelet therapy were essential.Results All the 36 patients were successively treated with balloon dilatation and stent angioplasty of venous sinus with exception of 3 cases,who failed because of the circuitous jugular foramen preventing the insertion of the stent.The successful rate was 91.7%.The cerebrospinal fluid pressure of the patients was lowered from 374.7±82.9mmH2O before operation to 230.3±48.1mmH2O after operation.Thirty-three patients were followed-up for 1 month to 8 years by brain angiography and examinations in the outpatient clinic.Among them 32 showed persistent relief of clinical symptoms.The remaining patient presented severe headache and optical visual blurring 1 month after stent implantation,however the symptoms were alleviated obviously after thrombolytic therapy via the carotid artery with adequate anticoagulation.Conclusions Stent angioplasty of venous

  6. Endovascular Device Testing with Particle Image Velocimetry Enhances Undergraduate Biomedical Engineering Education

    Science.gov (United States)

    Nair, Priya; Ankeny, Casey J.; Ryan, Justin; Okcay, Murat; Frakes, David H.

    2016-01-01

    We investigated the use of a new system, HemoFlow™, which utilizes state of the art technologies such as particle image velocimetry to test endovascular devices as part of an undergraduate biomedical engineering curriculum. Students deployed an endovascular stent into an anatomical model of a cerebral aneurysm and measured intra-aneurysmal flow…

  7. Preliminary clinical study on endovascular treatment of posterior inferior cerebellar artery aneurysms

    International Nuclear Information System (INIS)

    Zhao Bing; Zhong Ming; Tan Xianxi; Zheng Kuang; Zhang Mingsheng; Yin Jian; He Wengen

    2009-01-01

    Objective: To study the methods and results of endovascular treatment of posterior inferior cerebellar artery (PICA) aneurysms. Methods: Twenty-one patients with PICA aneurysms were treated with endovascular treatment. The locations of aneurysm on PICA were evaluated through the DSA. Eight patients received single coil embolization, 5 received liquid Glue embolization, 2 received coil embolization combined with liquid Glue, 2 received coil embolization assisted with stents, and 4 underwent occlusion of the parent PICA. Outcome was evaluated with the Glasgow outcome scale (GOS). Results: There were complete (100%) occlusion in 5 patients, near complete (> 90%) occlusion in 2, and incomplete (85%) occlusion in 1 in single coil embolization. Seven patients with Glue embolization (n=5) or combination with coils (n=2) exhibited complete (100%) occlusion. There were near complete (>90%) occlusion in 2 cases with coil assisted with stents. Complete occlusion of the parent PICA was achieved in 3 patients, and near complete occlusion of PICA in one case. One patient suffered from new neurological deficits, and one patient treated with coils and stents died. None of the patients suffered from re-bleeding. There patients received follow-up during a mean period of (22 ± 8) months. Overall long-term outcome was good (GOS score 4 or 5) in 17 patients, poor (GOS score 2 or 3) in 3, and fatal (GOS score 1 ) in one case. Conclusions: According to the location of aneurysms on PICA, aneurysms can be effectively and safely treated with endovascular embolization. (authors)

  8. Endovascular treatment of renal artery stenoses

    International Nuclear Information System (INIS)

    Lashari, M.N.

    2015-01-01

    To evaluate the procedure success and effect on hypertension after stenting of incidentally diagnosed atherosclerotic renal artery stenoses. Study Design: An experimental study. Place and Duration of Study: A multicentric study was conducted at the Plastic Surgery and General Hospital, National Medical Center and Ziauddin University Hospital, Karachi, Pakistan from January 2009 to March 2013. Methodology: Hypertension (systolic blood pressure > 160 and diastolic > 90 mmHg with two or more than two medications) with coronary artery disease were initially evaluated for coronary angiography, Renal artery angiography was also endovascular performed and stent was deployed for atherosclerotic renal artery stenosis when found. Blood pressure readings, reduction in need of antihypertensive medication and serum creatinine levels were taken as outcome measures. Patients having renal artery stenoses secondary to connective tissue disorders and fibromuscular dysplasia were excluded. Results: There were 25 patients, 14 (56%) male and 11 (44%) female, with mean age of 49 +- 6 years. Diabetes mellitus, dyslipidemia and smoking were seen in 11 (44%), 10 (40%) and 4 (16%) patients respectively. Renal insufficiency (serum creatinine > 1.5 mg/dl) was seen in one (04%) patient. Bilateral, and isolated right and left renal artery stenoses was seen in 5 (20%), 9 (36%) and 11(44%) patients respectively. Mean percentage of renal artery stenoses was 89%, ranged from 70% to 99% while ostial lesion was found in 20 (80%) patients. A significant decrease in systolic (168.20 +- 9.987 vs. 140.60 +- 5.649 mmHg, p < 0.001) and diastolic blood pressure (88.60 +- 5.50 vs. 77.20 +- 5.017 mmHg, p < 0.001) and reduction of medication (2.72 +- 0.458 vs. 1.5 +- 0.510, p < 0.01) were noted without a change in renal function (p= 0.061) after renal artery stenting. Conclusion: Endovascular stenting of renal artery stenoses in patients with poorly controlled hypertension is a safe and effective treatment

  9. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  10. Development of a dynamic in vitro model of a stented blood vessel to evaluate the effects of stent strut material selection and surface coating on smooth muscle cell response

    Science.gov (United States)

    Winn, Bradley Huegh

    formation of this new tissue, primarily consisting of VSMCs of the synthetic phenotype and their subsequent extracellular matrix, is the sole causation of in-stent restenosis since the stent serves to prevent elastic recoil and negative remodeling. This doctoral research program is focused on endovascular stent biomaterials science and engineering. Overall, this doctoral project is founded on the hypothesis that smooth muscle cell hyperplasia, as an important causative factor for vascular restenosis following endovascular stent deployment, is triggered by the various effects of stent strut contact on the vessel wall including contact forces and material biocompatibility. In this program, a dynamic in vitro model of a stented blood vessel aimed at evaluating the effect of stent strut material selection, and surface coating on smooth muscle cell response was developed. The in vitro stented artery model was validated through the proliferation of VSMC in contact with stent struts. Additionally, it was demonstrated that, with respect to known biocompatible materials such as Nitinol and 316L stainless steel, DNA synthesis and alpha-actin expression, as indicators of VSMC phenotype, are independent of stent material composition. Furthermore, hydroxyapatite was shown to be a biocompatible stent surface coating with acceptable post-strain integrity. This coating was shown in a feasibility study to be capable of serving as a favorable drug delivery platform able to reliably deliver locally therapeutic doses of bisphosphonates, such as alendronate, to control VSMC proliferation in an in vitro model of a stented blood vessel. This stent coating/drug combination may be effective for reducing restenosis as a result of VSMC hyperplasia in vivo.

  11. Lesion complexity drives the cost of superficial femoral artery endovascular interventions

    Science.gov (United States)

    Walker, Karen L.; Nolan, Brian W.; Columbo, Jesse A.; Rzucidlo, Eva M.; Goodney, Philip P.; Walsh, Daniel B.; Atkinson, Benjamin J.; Powell, Richard J.

    2017-01-01

    Objective Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. Methods A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. Results During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. Conclusions SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. PMID:26206581

  12. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  13. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  14. Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Bandorski, Dirk; Brueck, Martin; Guenther, Hans-Ulrich; Manke, Christoph

    2010-01-01

    Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16 patients with a thoracic endograft between 2001 and 2006. Medical records of the treated patients were studied. Data collected include age, gender, diagnosis, indication for endoluminal treatment, type of endograft, and time of follow up. All patients (n = 16; mean age, 61 years; range, 21-82 years) underwent computed tomography (CT) for location of the lesion and planning of the intervention. Time of follow-up with CT scan ranged from 1 to 61 months. Indications for endovascular treatment were degenerative aneurysm (n = 7; 44%), aortic dissection (n = 2; 12%), perforated aortic ulcer (n = 4; 25%), and traumatic aortic injury (n = 3; 19%). Three patients suffered from a collapse of the endograft (one patient distal, two patients proximal) between 3 and 8 days after endovascular treatment. These patients were younger (mean age, 37 ± 25 years vs. 67 ± 16 years; P 0.05]; distal, 45 ± 23.5% vs. 38 ± 21.7% [P > 0.05]). Proximal collapse was corrected by placing a bare stent. In conclusion, risk factors for stent-graft collapse are a small lumen of the aorta and a small radius of the aortic arch curvature (young patients), as well as oversizing, which is an important risk factor and is described for different types of endografts and protheses (Gore TAG and Cook Zenith). Dilatation of the collapsed stent-graft is not sufficient. Following therapy implantation of a second stent or surgery is necessary in patients with a proximal endograft collapse. Distal endograft collapse can possibly be treated conservatively under close follow-up.

  15. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  16. Multimodal Therapy for the Treatment of Severe Ischemic Stroke Combining Endovascular Embolectomy and Stenting of Long Intracranial Artery Occlusion

    Science.gov (United States)

    Bunc, Matjaž; Kocijančič, Igor J.; Pregelj, Rado; Dolenc, Vinko V.

    2010-01-01

    Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who—according to the National Institute of Health Stroke Scale (NIHSS)—was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach—without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA. PMID:20671974

  17. Multimodal therapy for the treatment of severe ischemic stroke combining endovascular embolectomy and stenting of long intracranial artery occlusion.

    Science.gov (United States)

    Bunc, Matjaz; Kocijancic, Igor J; Pregelj, Rado; Dolenc, Vinko V

    2010-01-01

    Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who-according to the National Institute of Health Stroke Scale (NIHSS)-was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach-without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA.

  18. Endovascular treatment of intracranial aneurysms with the p64 flow diverter stent: mid-term results in 35 patients with 41 intracranial aneurysms.

    Science.gov (United States)

    Morais, Ricardo; Mine, Benjamin; Bruyère, Pierre Julien; Naeije, Gilles; Lubicz, Boris

    2017-03-01

    The p64 flow diverter (FD) device is a fully resheathable and detachable stent dedicated for endovascular treatment (EVT) of intracranial aneurysms (IAs). We report our mid-term experience with this device. Between January 2015 and February 2016, we retrospectively identified, in our prospectively maintained database, all patients treated with p64 FDs in two institutions. Independent clinical follow-up was performed by a vascular neurologist. Imaging follow-up included a digitalized subtraction angiography (DSA) at 3, 6, and 12 months and a magnetic resonance angiography (MRA) at 12 months. Thirty-nine patients (22 women/17 men; median age 54 years) with 48 IAs (median aneurysm size 6.2 mm; mean neck size 3.4 mm) were identified. All IAs were saccular and unruptured. Failure of safe stent delivery occurred in 15% of cases (7/48 IAs) which were excluded. Transient neurological morbidity occurred in 2/35 patients (5.7%) including one delayed thromboembolic complication. No permanent morbidity or mortality was encountered. Complete aneurysmal occlusion at 3, 6, and 12 months was 20/30 (66.6%), 18/27 (66.6%), and 24/28 (85.7%), respectively. Intra-stent stenosis was observed in 9/29 patients (31%) and classified as moderate in 4/29 (13.7%) and mild in 5/29 patients (17.2%). These stenoses gradually improved over time, with only mild stenoses being identified at 6 months and at 12 months. In our small case series, the p64 FD stent appears safe and effective for EVT of IAs. A high occlusion rate and a low morbidity rate were observed.

  19. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  20. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  1. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  2. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  3. Analysis of the effect of stent porosity and shape on saccular intracranial aneurysm using the Lattice Boltzmann method Análisis del efecto de la porosidad y forma de un stent en un aneurisma sacular intracraneal utilizando el método Lattice Boltzmann

    Directory of Open Access Journals (Sweden)

    D S Ayala

    2013-11-01

    Full Text Available This article presents an analysis of blood flow patterns in intracranial saccular aneurysm and the effects of the shape and porosity of the stents used in endovascular treatments. In this study will be used the flow reduction criteria for characterizing the efficiency of the stent. The hemodynamic properties of a newtonian blood flow into the aneurysm will be evaluated using the Lattice Boltzmann method (LBM. Porosity values and stent forms are proposed for analysis. In all stent cases analyzed is observed a reduction of velocity and pressure and an increase in viscosity. It is further noted that the rectangular contour stent is the optimal case and reduces the magnitude of the flow velocity inside the aneurysm much as 76%. The results help to understand the role of porosity in the form and design of a stent.En este artículo se presenta un analísis de los patrones de flujo sanguíneo en un aneurisma sacular intracraneal y los efectos de la forma y la porosidad de los stents empleados en tratamientos endovasculares. En este estudio se empleará el criterio de reducción del flujo para caracterizar la eficiencia del stent. Se evaluarán las propiedades hemodinámicas de un flujo sanguíneo newtoniano dentro del aneurisma a partir del método de Lattice Boltzmann (LBM. Se proponen algunos valores de porosidad y forma de stent para el análisis. En todos los casos de stent analizados se observa una reducción de velocidades y presiones y un aumento de viscosidad. Se observa además que el stent de contorno rectangular es el caso óptimo y reduce la magnitud de la velocidad del flujo en el interior del aneurisma hasta en un 76 %. Los resultados obtenidos ayudan a entender el papel de la forma y porosidad en el diseño de un stent.

  4. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Evaluation of Silicone as an Endovascular Stent Membrane: In Vivo Canine Studies

    International Nuclear Information System (INIS)

    Fontaine, Arthur B.; Borsa, John J.; Hoffer, Eric; Bloch, Robert; So, Corali

    2001-01-01

    Purpose: Comparative evaluation of the biological effects of a silicone-covered stent versus a bare-metal stent, in an animal model.Methods: Twelve stent implants were placed in the iliac arteries of six adult dogs. Each animal received one 8-mm x 20-mm silicone-covered stent (Permalume; Boston Scientific Vascular, Watertown, MA, USA), in the right iliac artery and one Wallstent (Boston Scientific Vascular) of the same diameter and length in the left iliac artery, during systemic anticoagulation. Angiography was performed before and after implantations. Animals were then allowed to recover and no platelet suppression was given during a 6-week interval, after which the animals were euthanized. The stented arteries were isolated and pressure-fixed in situ with 10% buffered formalin at a pressure of approximately 100 mmHg for a period of 1 hr. Two of 12 stented specimens were opened lengthwise and the luminal surfaces were photographed. Ten of 12 stented arterial segments were encased in methacrylate, then stained with hematoxylin and eosin. Neointimal thickness was quantified on histologic cross-section, for both bare and covered stents. The mean neointimal thicknesses were compared for significant difference using a student t-test.Results: All implants were widely patent at 6-week follow-up angiography. Histologic analysis showed bare metal stents covered by a thin uniform lining of neointima composed of smooth muscle cells in a hyaline matrix (mean thickness of 189 ± 47 μm). Silicone covered stents were devoid of neointima. There was no chronic thrombus or mature endothelium noted anywhere upon the internal silicone surfaces of any of the specimens. There was no foreign body reaction to the silicone cover.Conclusion: Short-term implantation of a silicone-lined Wallstent in canine iliac arteries is well tolerated. Silicone appears to be inert at 6 weeks in this experimental application

  6. Endovascular Treatment of an Aortobronchial Fistula

    International Nuclear Information System (INIS)

    Numan, Fueruezan; Arbatli, Harun; Yagan, Naci; Demirsoy, Ergun; Soenmez, Binguer

    2004-01-01

    A 67-year-old man operated on 8 years previously for type B aortic dissection presented with two episodes of massive hemoptysis. An aortobronchial fistula was suspected with spiral computed tomography angiography, and showed a small pseudoaneurysm corresponding to the distal anastomotic site. The patient underwent endovascular stent-graft implantation and is asymptomatic 8 months after the procedure

  7. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed....... All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean...... arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered. Patients with cancer may only need treatment for the acute bleeding episode, and an endovascular approach has the advantage...

  8. Acute Iliac Artery Rupture: Endovascular Treatment

    International Nuclear Information System (INIS)

    Chatziioannou, A.; Mourikis, D.; Katsimilis, J.; Skiadas, V.; Koutoulidis, V.; Katsenis, K.; Vlahos, L.

    2007-01-01

    The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft is a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results

  9. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease.

    Science.gov (United States)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes T; Sun, Chao; Slump, Cornelis H; Goverde, Peter C J M; Versluis, Michel; Reijnen, Michel M P J

    2017-07-01

    Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry seems to affect patency. These variations may affect local flow patterns, resulting in different wall shear stress (WSS) and oscillating shear index (OSI). The aim of this study was to compare the effect of different stent configurations on flow perturbations (recirculation and fluid stasis), WSS, and OSI in an in vitro setup. Three different stent configurations were deployed in transparent silicone models: bare-metal kissing (BMK) stents, covered kissing (CK) stents, and the covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration. Transparent covered stents were created with polyurethane to enable visualization. Models were placed in a circulation setup under physiologic flow conditions. Time-resolved laser particle image velocimetry techniques were used to quantify the flow, and WSS and OSI were calculated. The BMK configuration did not show flow disturbances at the inflow section, and WSS values were similar to the control. An area of persistent low flow was observed throughout the cardiac cycle in the area between the anatomic bifurcation and neobifurcation. The CK model showed recirculation zones near the inflow area of the stents with a resulting low average WSS value and high OSI. The proximal inflow of the CERAB configuration did not show flow disturbances, and WSS values were comparable to control. Near the inflow of the limbs, a minor zone of recirculation was observed without changes in WSS values. Flow, WSS, and OSI on the lateral wall of the proximal iliac artery were undisturbed in all models. The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch

  10. Poly-lactic-acid coating of endovascular stents: preliminary results in canine experimental av-fistulae

    Energy Technology Data Exchange (ETDEWEB)

    Schellhammer, F. [Freiburg Univ. (Germany). Dept. of Neuroradiology; Koeln Univ. (Germany). Dept. of Radiology; Berlis, A. [Bonn Univ. (Germany). Dept. of Radiology; Bloss, H.G. [Freiburg Univ. (Germany). Dept. of Neurosurgery; Pagenstecher, A. [Freiburg Univ. (Germany). Dept. of Neuropathology; Schumacher, M. [Freiburg Univ. (Germany). Dept. of Neuroradiology

    2001-02-01

    Poly-Lactic-Acid (PLA) was evaluated for coating of vascular endoprotheses in the treatment of experimental arterio-venous-fistulae (AVF). Bilateral carotid-external jugular AVF were created in 5 adult dogs. 7 PLA coated nitinol stents were placed via a transfemoral approach covering 5 AVF. The contralateral AVF remained untreated. Angiography was performed immediately after stent placement, at weeks 1 and 3 and at months 3, 6 and 9. All grafts were removed and underwent histologic examination. In 2 cases the occlusion of the AVF was successful, while misplacement occurred in 3 cases. Occlusion of the parent vessel was disclosed in 3 cases. Histologic examination revealed a mild inflammatory reaction with the presence of macrophages. There was no foreign-body reaction or fragmentation of the arterial vessel wall. PLA, which is a well-known biodegradable material, showed a good mid-term biocompatibility. Elastic mismatch of the non-elastic coating and the self-expandable nitinol stent caused misplacement. Frequent vessel-occlusions were probably due to PLA-filaments fraying into the vessel lumen. Using a different textile structure PLA might be a material suitable for coating endovascular stents. (orig.) [German] In der vorliegenden Arbeit wurden mit Poly-Laktid ummantelte Gefaessprothesen in der Behandlung von experimentell angelegten arterio-venoesen Gefaesskurzschluessen getestet. Gefaesskurzschlussverbindungen der Halsarterien mit der parallel dazu verlaufenden, tiefen Halsvene wurden in 5 Hunden operativ angelegt. 7 mit Poly-Laktid ummantelte Gefaessprothesen aus Nitinol wurden in jeweils eine Halsarterie implantiert, so dass die Gefaesskurzschlussverbindungen vollstaendig ueberdeckt war. Die gegenueberliegende Seite verblieb als Kontrolle unbehandelt. Radiologische Gefaessdarstellungen erfolgten unmittelbar nach Implantation der Gefaessprothese, nach 1 und 3 Wochen sowie nach 3, 6 und 9 Monaten. Alle Prothesen wurden operativ entfernt und feingeweblich

  11. Clinical effectiveness of secondary interventions for restenosis after renal artery stenting

    Science.gov (United States)

    Simone, Thomas A.; Brooke, Benjamin S.; Goodney, Philip P.; Walsh, Daniel B.; Stone, David H.; Powell, Richard J.; Cronenwett, Jack L.; Nolan, Brian W.

    2013-01-01

    Objective Secondary interventions for renal artery restenosis (RAS) after renal artery stenting are common, despite limited data about their effectiveness. This study was designed to evaluate the outcomes of endovascular treatment of recurrent RAS. Methods We conducted a retrospective review of patients who underwent renal artery stenting between 2001 and 2011 at Dartmouth-Hitchcock Medical Center. Patients who required secondary interventions were compared with control patients who underwent only primary interventions for RAS. Multivariate regression models were used to identify factors associated with successful outcomes, as measured by changes in blood pressure, estimated glomerular filtration rate, and number of antihypertensive medications required. Results Sixty-five secondary (57 patients) renal interventions were undertaken for recurrent RAS associated with progressive hypertension or renal dysfunction and compared with outcomes after 216 primary (180 patients) renal artery stenting procedures. Patients undergoing primary vs secondary interventions did not differ significantly in the number of preoperative antihypertensive medications used, comorbid conditions, or blood pressure. All primary and secondary interventions were performed with stents and showed no difference in procedural complications. At a mean follow-up of 23 months (range, 1–128 months), similar improvements in renal function and blood pressure were found between patients undergoing primary and secondary interventions, and there was no difference in rates of restenosis or survival between cohorts. Regression models showed that the use of embolic protection devices was associated with improved renal function after primary (odds ratio [OR], 2.0; 95% confidence interval [CI], 1.1–3.8; P < .05) and secondary (OR, 4.7; 95% CI, 1.7–12.5; P < .05) interventions, whereas statin therapy was associated with improved renal (OR, 2.0; 95% CI, 1.3–3.2; P < .05) and blood pressure response (OR, 4

  12. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    Science.gov (United States)

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  13. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    Science.gov (United States)

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  14. [Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms].

    Science.gov (United States)

    Pitton, M B; Schmiedt, W; Neufang, A; Düber, C; Thelen, M

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings.

  15. Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitton, M.B.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings. (orig.)

  16. Development of radiolabelled compound using reactor producted RI - Evaluation of Ho-166 endovascular therapy to prevent restenosis after PTCA or stenting for occlusive coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Hee; Choi, Byung Il; Kim, Han Soo [Ajou University, Suwon (Korea)

    2000-04-01

    Occlusive coronary artery disease is managed successfully by percutaneous transfemoral coronary angioplasty (PTCA) or stenting with 95% success rate. However, restenosis after PTCA is not uncommon and the reported incidence of reocclusion is about 30 {approx} 40%. Therefore, the objective of the research was to develop endovascular brachytherapy using liquid form of Ho-166 in order to inhibit neointimal hyperplasia responsible for restenosis following PTCA or stenting. Our research was carried out in 3 stages: First stage - The effectiveness of radiation was confirmed by using animal model. Following over-sized balloon injury to rat carotid artery and porcine coronary artery, various external radiation doses were delivered. Second stage - For radiation dose distribution within the coronary artery and its surrounding tissues, Gafchromic film was used. In vitro dose distribution of Ho-166 utilizing water phantom and Gafchromic film was measured. Third stage - None uniform dose distribution from Ho-166 within the balloon caused by small air bubbles was eliminated by negative suction method. More accurate dose distribution was also possible using newly developed micrometer by our physicist. Limited number of human trial was performed without adverse effect. 40 refs. (Author)

  17. Endovascular Management of Aorta-Iliac Stenosis and Occlusive Disease by Kissing-Stent Technique

    Directory of Open Access Journals (Sweden)

    Meng Liu

    2016-01-01

    Full Text Available Kissing-stenting treatment has been used to treat patients with peripheral artery disease (PAD. However, the long term efficacy of the stenting therapy is not well defined in Chinese PAD patients. To investigate the question, sixty-three PAD patients (37 males and 26 females, aged 66±7.3 years, were analysed in the study. They were featured as claudication (n=45, 71.4%, rest pain (n=18, 28.6%, or gangrene (n=8, 12.7%. In total, 161 stents were applied in aorta-iliac lesions with 2.6 stents for each patient, including 55 self-expanding stents, 98 balloon expandable stents, and 8 covered stents. The success rate of implanting Kissing-stents was 100%. Catheter-directed thrombolysis (CDT with urokinase was performed in 8 cases (12.7%. The severity of peripheral ischemia was significantly improved, as evidenced by 3.3-fold increase of ankle-brachial pressure index (ABI after the surgery (P=0.008. One, three, five, and seven years after surgery, the primary patency rate was 87.3%, 77.4%, 71.1%, and 65.0%, whereas the secondary patency rate was 95.2%, 92.5%, 89.5%, and 85.0%, respectively. No in-hospital mortality was recorded. In conclusion, Kissing-stenting technique for aorta-iliac lesions is safe and effective with lower complications. It is beneficial for aorta-iliac occlusions that are longer than 60 mm.

  18. Endovascular repair as a sole treatment in multiple aneurysms in patient with SLE

    International Nuclear Information System (INIS)

    Dineva, S.; Al-Amin, M.; Demetriou, S.; Tsetis, D.

    2013-01-01

    Full text: Introduction: Most aneurysms are local manifestations of systemic disease. For patients over 65 years the incidence of aneurysm of the abdominal aorta (AAA) is approximately 5-6% in men and 1-2 % for women. The presence of both the AAA and aneurysms in other location is even rarer, and this percentage is likely increase further in patients with systemic lupus erythematosus (SLE). What you will learn: We present a rare clinical case of endovascular treatment of multifocal aneurysm including post catheterization pseudoaneurysm. The patient is a 73 years old woman with a history of SLE and age-related comorbidity. Originally an endovascular treatment of aneurysms of the abdominal aorta and right common iliac artery was used. Two years later a successfully endovascular treatment of aneurysm of the right renal artery was conducted, which however is complicated by the formation of a pseudoaneurysm in access through the left femoral artery. The late one is again treated endovascular by placement of a covered stent after failure of percutaneous injection of 1000 UI thrombin. Discussion: Adult patients with a long history of SLE are unsuitable candidates for surgical treatment of aneurysmal disease, especially in its multifocal form. In our case we have taken multistep successful endovascular procedures, including technically hard placing of the stent at the site of the right renal aneurysms, and post catheterization pseudoaneurysm. Conclusion: Multifocal aneurysmal vascular changes due to macroangiopathia in SLE can be treated alone by endovascular means in multi-stages procedures

  19. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  20. Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Recaldini, Chiara; Lumia, Domenico; Cuffari, Salvatore; Caronno, Roberto; Castelli, Patrizio; Fugazzola, Carlo

    2007-01-01

    Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach

  1. Endovascular Therapy Is Effective for Leriche Syndrome with Deep Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Tasuku Higashihara

    2015-01-01

    Full Text Available A 65-year-old man presented to our hospital due to intermittent claudication and swelling in his left leg. He had Leriche syndrome and deep vein thrombosis. We performed endovascular therapy (EVT for Leriche syndrome, and a temporary filter was inserted in the inferior vena cava. He received anticoagulation therapy for deep vein thrombosis. The stenotic lesion in the terminal aorta was stented with an excellent postprocedural angiographic result and dramatic clinical improvement after EVT. This case suggests that EVT can be a treatment for Leriche syndrome.

  2. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  3. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    Science.gov (United States)

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  4. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  5. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for

  6. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  7. Alternativa técnica no tratamento endovascular dos aneurismas da artéria poplítea A technical alternative for the endovascular treatment of popliteal artery aneurysms

    Directory of Open Access Journals (Sweden)

    Marcelo Ferreira

    2008-03-01

    Full Text Available O aneurisma de artéria poplítea é relativamente raro, porém representa cerca de 85% de todos os aneurismas arteriais periféricos. Apresenta-se geralmente com um quadro de complicação isquêmica e elevado risco de perda do membro acometido. Em função disso, preconiza-se seu tratamento eletivo, atualmente realizado com resultados satisfatórios pela técnica endovascular. Relatamos nossa experiência com a utilização do stent de nitinol auto-expansível revestido com PTFEe - Fluency (Bard, Alemanha, reforçado internamente com o stent de nitinol auto-expansível Zilver (Cook, EUA no tratamento de um aneurisma de artéria poplítea.Popliteal artery aneurysm is relatively rare, but represents around 85% of all peripheral arterial aneurysms. It is usually presented with ischemic complication and high risk of limb loss. For that reason, its elective treatment is indicated and currently carried through with satisfactory results using endovascular techniques. We describe our experience with the use of an ePTFE-covered nitinol self-expandable stent graft - Fluency (Bard, Germany, reinforced internally with the nitinol self-expandable Zilver stent (Cook, USA for the treatment of a popliteal artery aneurism.

  8. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  9. Recognition and treatment of outflow tract stenosis during and after endovascular exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Lu Qingsheng; Jing Zaiping; Zhao Zhiqing; Bao Junmin; Zhao Jun; Feng Xiang; Feng Rui; Huang Sheng

    2003-01-01

    Objective: To study the cognition and treatment of outflow tract stenosis in and after endovascular exclusion for abdominal aortic aneurysm. Methods: From Mar 1997 to Oct 2002, in 136 patients undergoing abdominal aortic aneurysm endovascular exclusion, 8 patients had outflow tract stenosis during the operation, and 3 patients had outflow tract stenosis after operation. The stenosis of 5 patients occurred at the crotch of the graft-stent. PTA was done in 7 patients and stents were placed in stenotic segment in 2 patients. 2 patients were treated with crossover operation. Results: Following up 1 month to 2 years, all patients have no lower limbs ischemia. Conclusions: The diagnosis of outflow tract stenosis during and after abdominal endovascular exclusion for aortic aneurysm must be in time. The treatment should be according to the different causes of stenosis

  10. Enterprise stent in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Ji, Yong; Ding, Xuan; Zang, Yizheng; Wang, Chengwei

    2017-11-01

    To investigate the safety and effectiveness of recanalization in non-acute occlusion of intracranial internal carotid arteries using the flexible Enterprise self-expanding stent. From June 2014 to June 2016, 12 consecutive patients with non-acute occlusion of intracranial internal carotid arteries received endovascular recanalization with Enterprise stenting. All patients received medication for anti-platelet aggregation therapy before and after the operation. The perioperative complications and recanalization efficacy were evaluated with the modified Rankin scoring system and digital subtraction angiography (DSA) follow-up, respectively. Endovascular recanalization was successfully performed in 10 out of 12 patients with Enterprise stenting. Stent implantation following balloon dilatation failed in one patient because the lumen diameter was too small. Another recanalization failed because the guide wire could not pass through the occlusion. No perioperative mortality was observed. One case of acute thrombosis and one case of intraoperative carotid spasm occurred, but these were resolved with thrombolytic therapy by microcatheter exposure treatment and antispasmodic medications, respectively. DSA follow-up in seven patients revealed no re-occlusion. One stroke event occurred in the 10 patients who completed the follow-up. A meaningful improvement in the modified Rankin score during follow-up was suggested by Wilcoxon signed-rank test results. The Enterprise stent was shown to be safe and efficient in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion. However, the long-term outcomes need to be further investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Outcomes of Peripheral Endovascular Interventions Based on Hospital Volume: A Mini Review of Published Literature

    Directory of Open Access Journals (Sweden)

    Samir V Patel

    2016-01-01

    Full Text Available Previous literature showed hospital procedural volume is an independent predictor for outcomes of various cardiac procedures. However, very few studies shown similar results for peripheral endovascular interventions especially peripheral atherectomy. Here we are reviewing previously published articles to provide volume-outcome relationship for peripheral atherectomy and angioplasty with or without endovascular stenting. We found higher hospital volume significantly and independently lowers in-hospital mortality, amputation rates, peri-procedural complications, length and cost of hospitalization for peripheral endovascular interventions.

  12. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  13. A collaborative sequential meta-analysis of individual patient data from randomized trials of endovascular therapy and tPA vs. tPA alone for acute ischemic stroke: ThRombEctomy And tPA (TREAT) analysis: statistical analysis plan for a sequential meta-analysis performed within the VISTA-Endovascular collaboration

    NARCIS (Netherlands)

    MacIsaac, Rachael L.; Khatri, Pooja; Bendszus, Martin; Bracard, Serge; Broderick, Joseph; Campbell, Bruce; Ciccone, Alfonso; Dávalos, Antoni; Davis, Stephen M.; Demchuk, Andrew; Diener, Hans-Christoph; Dippel, Diederik; Donnan, Geoffrey A.; Fiehler, Jens; Fiorella, David; Goyal, Mayank; Hacke, Werner; Hill, Michael D.; Jahan, Reza; Jauch, Edward; Jovin, Tudor; Kidwell, Chelsea S.; Liebeskind, David; Majoie, Charles B.; Martins, Sheila Cristina Ouriques; Mitchell, Peter; Mocco, J.; Muir, Keith W.; Nogueira, Raul; Saver, Jeffrey L.; Schonewille, Wouter J.; Siddiqui, Adnan H.; Thomalla, Götz; Tomsick, Thomas A.; Turk, Aquilla S.; White, Philip; Zaidat, Osama; Lees, Kennedy R.

    2015-01-01

    Endovascular treatment has been shown to restore blood flow effectively. Second-generation medical devices such as stent retrievers are now showing overwhelming efficacy in clinical trials, particularly in conjunction with intravenous recombinant tissue plasminogen activator. This statistical

  14. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  15. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  16. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  17. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  18. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    International Nuclear Information System (INIS)

    Zhang, Qingqiao; Huang, Qianxin; Shen, Bin; Sun, Jingmin; Wang, Xiaolong; Liu, Hongtao

    2015-01-01

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or two hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion

  19. Anastomotic pseudoaneurysms after surgical reconstruction: Outcomes after endovascular repair of symptomatic versus asymptomatic patients

    International Nuclear Information System (INIS)

    Nolz, Richard; Gschwendtner, Manfred; Jülg, Gregor; Plank, Christina; Beitzke, Dietrich; Teufelsbauer, Harald; Wibmer, Andreas; Kretschmer, Georg; Lammer, Johannes

    2012-01-01

    Purpose: To compare perioperative and follow-up outcomes of symptomatic versus asymptomatic patients following endovascular repair of anastomotic pseudoaneurysms (APAs) of the abdominal aorta and iliac arteries. Methods: We retrospectively evaluated 17 patients (two women), with a mean age of 66.2 years (range 30–83 years). Endovascular treatment was performed in ten symptomatic, and seven asymptomatic patients electively. Data included technical success, perioperative (within 30 days) mortality and morbidity, as well as stent graft-related complications, reinterventions, and survival in follow-up. Results: Bifurcated (n = 13), aortomonoiliac (n = 3) endoprosthesis and one aortic cuff were implanted with a primary technical success rate of 100%. The overall in-hospital mortality and morbidity rate was 11.8% and 35.3%. The mean survival was 36.5 (range 0–111) months. There was a clear trend toward a lower overall survival within hospital and at one and three years for symptomatic patients compared to asymptomatic patients. (47.7 (CI: 0–138.8) versus 52.6 (CI: 28.5–76.8) months (p = 0.274)). During follow-up, late stent graft related complications were observed in six patients (35.3%) necessitating eight endovascular reinterventions. Additional three patients with primary fistulas between the APA and the intestine were treated by late surgical revision. Conclusion: Endovascular therapy of APAs represents a considerable alternative to open surgical repair. Short proximal anchoring zones still pose a risk for endoleaks and unintentional overstenting of side branches with commercially available devices, but this might be overcome by use of fenestrated and branched stent grafts in elective cases.

  20. Endovascular Treatment for Fusiform Dilation of Internal Carotid Artery Following Craniopharyngioma Resection: A Case Illustration.

    Science.gov (United States)

    Li, Qiang; Wang, Chaohua; Xu, Jianguo; You, Chao

    2015-09-01

    Fusiform dilation of the internal carotid artery complicates aggressive craniopharyngioma resection and occurs mainly in children. We report a case to describe the availability of endovascular treatment for this rare entity. A 13-year-old boy presented with headache for 2 years after resection of craniopharyngioma. A fusiform dilation of the right carotid artery was found and was coiled using stent-assisted technique. Follow-up showed satisfactory outcome and disappearance of headache. To our knowledge, this is the first report regarding endovascular treatment for fusiform dilation of the internal carotid artery after craniopharyngioma resection. Stent-assisted coiling is a useful approach for fusiform dilation of the internal carotid artery following craniopharyngioma surgery. © The Author(s) 2014.

  1. Superficial femoral artery TASC D Registry: twelve-month effectiveness analysis of the Pulsar-18 SE nitinol stent in patients with critical limb ischemia.

    Science.gov (United States)

    Lichtenberg, M; Stahlhoff, W; Boese, D

    2013-08-01

    Single center observational study analyzing the primary patency rate and freedom from target lesions revascularization rate of the Pulsar-18 nitinol stent after recanalization of long superficial femoral artery (SFA) occlusions (TASC D) in 22 patients with critical limb ischemia (CLI). Between 1/2011 and 7/2011, 22 consecutive patients (9 male, 13 female) with chronic total occlusions (CTO) of the femoro-popliteal arteries presenting with CLI (17 patients with Rutherford 4 score, and 5 patients with Rutherford 5 score) were enrolled and successfully recanalized using the Pulsar-18 self-expanding (SE) nitinol stent (BIOTRONIK AG, Buelach, Switzerland). Primary patency at 12 months was defined as no binary restenosis (>50%) on Duplex ultrasound (PSVRPulsar-18 SE nitinol stent was 77% with a per protocol restenosis in 5 of 22 patients. Seventeen patients showed a walking capacity on treadmill test >300 meters (Rutherford II). Two patients with a documented restenosis were Rutherford, these patients were treated conservatively. Three patients with restenosis and a Rutherford III score were scheduled for an endovascular target lesion revascularization leading to a freedom from target lesion revascularization rate of 86%. Endovascular intervention of long SFA occlusions using subintimal or intraluminal recanalization technique with implantation of the Pulsar-18 SE nitinol stent in CLI patients is safe and clinically effective with a primary patency rate after 12 months of 77% and a freedom from target lesion revascularization rate of 86%.

  2. An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization

    Energy Technology Data Exchange (ETDEWEB)

    Negri, Silvia; Ferraro, Stefania; Piffaretti, Gabriele, E-mail: gabriele.piffaretti@uninsubria.it; Rivolta, Nicola; Bossi, Matteo [University of Insubria School of Medicine, Vascular Surgery, Department of Surgical Sciences, Circolo University Hospital (Italy); Carrafiello, Gianpaolo [University of Insubria School of Medicine, Interventional Radiology, Department of Radiology, Circolo University Hospital (Italy); Castelli, Patrizio [University of Insubria School of Medicine, Vascular Surgery, Department of Surgical Sciences, Circolo University Hospital (Italy)

    2012-08-15

    A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.

  3. An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization

    International Nuclear Information System (INIS)

    Negri, Silvia; Ferraro, Stefania; Piffaretti, Gabriele; Rivolta, Nicola; Bossi, Matteo; Carrafiello, Gianpaolo; Castelli, Patrizio

    2012-01-01

    A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.

  4. Anchoring barbs and balloon expandable stents: what is the risk of perforation and failed stent deployment?

    Science.gov (United States)

    Bown, M J; Harrison, G J; How, T V; Brennan, J A; Fisher, R K; Vallabhaneni, S R; McWilliams, R G

    2012-09-01

    Balloon expandable stents may on occasion be deployed in close proximity to the anchoring barbs of endovascular grafts. The aim of this study was to determine the risk and effect of balloon perforation by anchoring barbs and to assess whether these risks are different if the balloon is protected by a covered stent mounted upon it. A bench-top model was developed to mimic the penetration of anchoring barbs into the lumen of medium sized blood vessels. The model allowed variation of angle and depth of vessel penetration. Both bare balloons and those with covered stents mounted upon them were tested in the model to determine whether there was a risk of perforation and which factors increased or decreased this risk. All combinations of barb angle and depth caused balloon perforation but this was most marked when the barb was placed perpendicular to the long axis of the balloon. When the deployment of covered stents was attempted balloon perforation occurred in some cases but full stent deployment was achieved in all cases where the perforation was in the portion of the balloon covered by the stent. The only situation in which stent deployment failed was where the barb was intentionally placed in the uncovered portion of the balloon. This resulted in only partial deployment of the stent. Balloon rupture is a distinct possibility when deploying balloon-expandable stents in close proximity to anchoring barbs. Care should be taken in this circumstance to ensure that the barb is well away from the uncovered portion of the balloon. Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Current status and outlook of endovascular therapy for cerebral ischemic diseases

    International Nuclear Information System (INIS)

    Li Minghua; Zhao Jungong

    2005-01-01

    Improvement of diagnostic technology and increasing advent of new materials for intervention has created a new area for endovascular therapy of cerebral ischemic diseases. Current research findings have shown that endovascular thrombolysis in acute stage of cerebral infarction can accelerate the rate of re-canalization of occluded arteries and greatly decrease the morbidity and mortality of cerebral ischemic vascular diseases. Stenting of arterial stenosis can the improve of blood supply distal to the lesion, prevent recurrent cerebral ischemic stroke. As a result, endovascular thrombolysis for acute cerebral infarction and stenting for intracranial and carotid arterial stenosis are booming both at home and abroad. Proper selection of patients of acute cerebral infarction for endovascular thrombolysis with less complications could be achieved through CT perfusion, MR perfusion-weighted image (PWI) and diffusion-weighted image (DWI), non-invasive vascular imaging technology including CEMRA and CTA for confirming and demonstrating the sites and causes of cerebral ischemia, and furthermore for evaluating the survival ability and etc. The research team administered albumin and magnesium sulfate as neurological protection drug to treat rat infarction model within 6 hours of onset resulting with the same effect of decreasing the damage of ischemic cerebral tissue and without hemorrhagic complication. It is certain that hemorrhagic complication in thrombolysis is a result of multiple factors with no single drug being able to solve the problem. It is predictable that, based on semi-quantitative or quantitative parameters of CT or MRI in conjunction with PWI/DWI mismatch model rather than simply on the onset time of infarction for proper selection of patients of cerebral infarction, mechanic thrombus-disruption and/or intra-arterial thrombolysis together with intervention of neurological protection drug will be the trend for treating acute cerebral infarction in the future

  6. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

    International Nuclear Information System (INIS)

    Rimon, Uri; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Galili, Yair; Schneiderman, Jacob; Morag, Benyamina

    2004-01-01

    Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn

  7. Use of flow-diverting stents as salvage treatment following failed stent-assisted embolization of intracranial aneurysms.

    Science.gov (United States)

    Heiferman, Daniel M; Billingsley, Joshua T; Kasliwal, Manish K; Johnson, Andrew K; Keigher, Kiffon M; Frudit, Michel E; Moftakhar, Roham; Lopes, Demetrius K

    2016-07-01

    Flow-diverting stents, including the Pipeline embolization device (PED) and Silk, have been beneficial in the treatment of aneurysms previously unable to be approached via endovascular techniques. Recurrent aneurysms for which stent-assisted embolization has failed are a therapeutic challenge, given the existing intraluminal construct with continued blood flow into the aneurysm. We report our experience using flow-diverting stents in the repair of 25 aneurysms for which stent-assisted embolization had failed. Nineteen (76%) of these aneurysms at the 12-month follow-up showed improved Raymond class occlusion, with 38% being completely occluded, and all aneurysms demonstrated decreased filling. One patient developed a moderate permanent neurologic deficit. Appropriate stent sizing, proximal and distal construct coverage, and preventing flow diverter deployment between the previously deployed stent struts are important considerations to ensure wall apposition and prevention of endoleak. Flow diverters are shown to be a reasonable option for treating previously stented recurrent cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Innovations in vascular and endovascular surgery in Brazil: a data analysis study

    Directory of Open Access Journals (Sweden)

    Heriberto Brito de Oliveira

    2014-12-01

    Full Text Available Background:Innovations in vascular and endovascular surgery have important social and economic repercussions. Most endovascular devices used in Brazil are imported and, therefore, particularly expensive.Objective:To conduct a retrospective analysis of patent and regulatory approval data for newly developed vascular and endovascular devices, based on the number of patents registered at the Brazilian National Industrial Property Institute (INPI and the number of products approved by the National Health Surveillance Agency (ANVISA over recent years.Methods:This retrospective study involved electronic searches of the INPI (www.inpi.gov.br and ANVISA websites (www.anvisa.gov.br, for patents registered and products approved between January 1997 and December 2012.Results:The keywords used for the search ("catheter(s," "stent(s," "graft(s," and "wound dressing(s" returned a total of 701 new patents registered during the period studied. Thirty-four percent (n=237 of these were patents for wound dressings, while the remaining 66% (n=464 were for devices used in endovascular surgery. Only 7.8% (n=268 of the 3433 products approved by ANVISA during the period analyzed were produced in Brazil.Conclusions:The social and economic importance of innovations in health care highlights the need to monitor them, to register them and to support their production, in view of the need to develop local alternatives to imported health care technology.

  9. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  10. Comparison of the occlusion of experiemntal craniojugular saccular aneurysms with covered stents

    International Nuclear Information System (INIS)

    Zhang Haixia; Li Minghua; Cheng Yingsheng; Fang Chun; Li Min

    2006-01-01

    Objective: To assess the effectiveness and biocompatibility of balloon-expanding, stainless steel stents covered with biomembrane (BM-SSS) and polyurethane membrane (PUM-SSS) in the treatment of experimental saccular aneurysms in a canine model and to observe the ablation of aneurysm with preservation of the parent vessel. Methods: Sixteen healthy mongrel canines were included in our study. 26 of 29 successful experimental aneurysms were treated with covered stents, another 3 were untreated to serve as controls. Altogether there were fourteen BM-SSS and twelve PUM-SSS were placed endovascularly in the common carotid arteries covering the orifice of the aneurysms. Control angiography was performed immediately after the procedure and after 2 weeks, 4 weeks and 12 weeks. According to grouping time, each aneurysm together with stented arteries was removed with animals alive for histopathological examination. Enumeration data was analyzed by Fisher's Exact Test using SPSS 10.0. Results: Before stent placement, angiography of the common carotid arteries showed round, saccular side-wall aneurysms and complex pattern of flow. Immediately after stent placement the aneurysmal pouches were no longer visible and the stented common carotid arteries remained widely patent. All controlled aneurysms and common carotid arteries have been patent and unchanged for 1 year. 13 of 14 stented common carotid arteries with BM-SSS and 3 of 12 with PUM-SSS remained widely patent. The complete patency rate of BM-SSS and PUM-SSS was significantly different (P=0.0008). Histological analysis indicated that all treated aneurysmal pouches were almost filled with thrombus, as well as with fibrotic reactive scar tissue. Stent wires were found to be located deep within the vessel wall and encased by an extension of the tunica intima. The endothelium of the two groups was already mature at 12 weeks, and various degree of degenerate cells were seen under the transmission electron microscopy. Conclusion

  11. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  12. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  13. Feasibility of Using Intravascular Ultrasonography for Assessment of Giant Cavernous Aneurysm after Endovascular Treatment: A Technical Report

    Science.gov (United States)

    Majidi, Shahram; Grigoryan, Mikayel; Tekle, Wondwossen G; Watanabe, Masaki; Qureshi, Adnan I

    2012-01-01

    Introduction Intravascular ultrasonography (IVUS) has been shown as a valuable adjunct imaging tool during endovascular procedures but its value in detection of any recurrence during follow up after endovascular coil embolization of large and giant intracranial aneurysms is not reported. Methods A 41 years old man who had been treated using stent assisted coil embolization for cavernous segment aneurysm of the left internal carotid artery underwent 60 month angiographic follow up. Concurrently, IVUS catheter was advanced under fluoroscopic guidance inside the cavernous portion of the left internal carotid artery. Then IVUS images were used to visualize the stent, coil loops, and aneurysm neck. Results The angiographic images were limited because of superimposition of the aneurysm on the parent vessel in all projections. IVUS images demonstrated that the stent was patent along its whole length and there was no sign of stent deformity or in-stent thrombosis. Loops of the coil were visualized as hyperechoic signals inside the aneurysm and there was no sign of herniated loops of coil inside the stent. Conclusion In this case report, we observed that adjunct use of IVUS can provide valuable information not ascertained by angiography during follow up assessment of coil embolized aneurysm. PMID:22737259

  14. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  15. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Petrocelli, Francesco; Seitun, Sara; Robaldo, Alessandro; Mazzei, Raffaele

    2011-01-01

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  16. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  17. Long-term success of endovascular treatment of benign superior vena cava occlusion with chylothorax and chylopericardium

    Energy Technology Data Exchange (ETDEWEB)

    Veroux, Pierfrancesco; Veroux, Massimiliano; Bonanno, Maria Giovanna; Tumminelli, Maria Giuseppina [Department of Surgery and Transplantation, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy); Baggio, Elda [Department of Surgery and Gastroenterological Sciences, University Hospital of Verona (Italy); Petrillo, Giuseppe [Department of Radiology, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy)

    2002-07-01

    The most likely etiology of benign obstruction of the superior vena cava (SVC) include fibrosing mediastinitis and iatrogenic etiologies such as sclerosis and obstruction caused by pacemakers and central venous catheter. Percutaneous stenting of SVC has been used with success both in malignant and benign superior vena cava syndrome; however, long-term follow-up of endovascular procedures is not well known. We present a case of a patient with complete occlusion of SVC of benign etiology, presenting dramatically with bilateral chylothorax and chylopericardium with cardiac tamponade, who underwent successful vena caval revascularization with thrombolytic therapy and placement of self-expanding metallic stent. The 42-month follow-up could encourage endovascular procedures even in SVC syndrome of benign etiology. (orig.)

  18. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  19. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  20. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  1. Endovascular Treatment of a Carotid Dissecting Pseudoaneurysm in a Patient with Ehlers-Danlos Syndrome Type IV with Fatal Outcome

    International Nuclear Information System (INIS)

    Lim, Siok Ping; Duddy, Martin J.

    2008-01-01

    We present a patient with Ehlers-Danlos syndrome type IV (EDS IV) with a carotid dissecting pseudoaneurysm causing severe carotid stenosis. This lesion was treated endovascularly. Unfortunately, the patient died of remote vascular catastrophes (intracranial hemorrhage and abdominal aortic rupture). This unique case illustrates the perils of endovascular treatment of EDS IV patients and the need for preoperative screening for concomitant lesions. It also shows that a dissecting pseudoaneurysm can feasibly be treated with a covered stent and that closure is effective using Angioseal in patients with EDS IV

  2. Endovascular graft exclusion in treating thoracic aortic dissection: a report of 25 cases

    International Nuclear Information System (INIS)

    Chen Wei; Yang Jianyong; Zhuang Wenquan; Guo Wenbo; Li Heping; Zhong Lizhen; Huang Qiuping

    2003-01-01

    Objective: To evaluate the usefulness and efficacy of endovascular graft exclusion (EVGE) in treating thoracic aortic dissection (TAD). Methods: Twenty-five cases of TAD, including 24 cases of Standford B and 1 case of A, were treated by EVGE. The clinical outcome and morphological changes of the lesions were analyzed during a 2-20 months' follow-up. Results: Procedures were technically successful in all 25 cases, while a total of 28 stent-grafts were deployed (3 cases with 2 stent-grafts in each). Complete disappearance of the false lumen or remarkable decrease of the endoleak was noted on the angiograms after stent placement. No severe procedure-related complication was observed, and thrombosis of the false lumen was noted during the follow-up. Conclusion: EVGE is effective and reliable in treating TAD, especially for patients with sub-acute or chronic courses

  3. Aortic arch/elephant trunk procedure with Sienna(TM) graft and endovascular stenting of thoraco-abdominal aorta for treatment of complex chronic dissection.

    Science.gov (United States)

    Wong, Randolph H L; Baghai, Max; Yu, Simon C H; Underwood, Malcolm J

    2013-05-01

    Aneurismal dilatation of the remaining thoracic aorta after ascending aortic interposition grafting for type 'A' aortic dissection is not uncommon. For such complex cases, one treatment option is total arch replacement and elephant trunk procedure with the Sienna(TM) collared graft (Vascutek, Inchinnan, UK) technique followed by a staged thoracic endovascular aortic repair (TEVAR). The video illustrates our technique in a 56-year-old man with an extensive aortic arch and descending thoracic aortic dissecting aneurysm. For the 'open' procedure femoral arterial and venous cannulation was used along with systemic cooling and circulatory arrest at 22 °C. Upon circulatory arrest, the aortic arch was incised and antegrade cerebral perfusion achieved via selective cannulation to the right brachiocephalic and left common carotid artery, keeping flow rates at 10-15 mL/kg/min and perfusion pressure at 50-60 mmHg. Arch replacement with an elephant trunk component was then performed and after completion of the distal aortic anastomosis antegrade perfusion via a side-arm in the graft was started and the operation completed using a variation of the 'sequential' clamping technique to maximize cerebral perfusion. The second endovascular stage was performed two weeks after discharge. Two covered stents were landing from the elephant trunk to the distal descending thoracic aorta, to secure the distal landing a bare stent of was placed to cover the aorta just distal to the origin of the celiac axis. The left subclavian artery was embolised with fibre coils. Post TEVAR angiogram showed no endoleak Although re-operative total arch replacement and elephant trunk procedure and subsequent TEVAR remained a challenging procedure, we believe excellent surgical outcome can be achieved with carefully planned operative strategy.

  4. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model.

    Science.gov (United States)

    Boersen, Johannes T; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H; Ku, David N; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-12-01

    Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is different from a bifurcation with a tapered trajectory of the flow lumen into the two limbs and may induce unfavorable flow conditions. These include low and oscillatory wall shear stress (WSS), linked to atherosclerosis, and high shear rates that may result in thrombosis. An in vitro study was performed to assess the impact of EVAR and EVAS on flow patterns and WSS. Four abdominal aortic aneurysm phantoms were constructed, including three stented models, to study the influence of the flow divider on flow (Endurant [Medtronic, Minneapolis, Minn], AFX [Endologix, Irvine, Calif], and Nellix [Endologix]). Experimental models were tested under physiologic resting conditions, and flow was visualized with laser particle imaging velocimetry, quantified by shear rate, WSS, and oscillatory shear index (OSI) in the suprarenal aorta, renal artery (RA), and common iliac artery. WSS and OSI were comparable for all models in the suprarenal aorta. The RA flow profile in the EVAR models was comparable to the control, but a region of lower WSS was observed on the caudal wall compared with the control. The EVAS model showed a stronger jet flow with a higher shear rate in some regions compared with the other models. Small regions of low WSS and high OSI were found near the distal end of all stents in the common iliac artery compared with the control. Maximum shear rates in each region of interest were well below the pathologic threshold for acute thrombosis. The different stent designs do not influence suprarenal flow. Lower WSS is observed in the caudal wall of the RA after EVAR and a higher shear rate after EVAS. All stented models have a small region of low WSS and high OSI near the distal outflow

  5. Safety and efficacy of transhepatic and transsplenic access for endovascular management of portal vein complications after liver transplantation.

    Science.gov (United States)

    Ohm, Joon-Young; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu

    2017-09-01

    The purpose of this article is to evaluate and compare the safety and efficacy of endovascular management of the portal vein (PV) via percutaneous transsplenic access versus percutaneous transhepatic access in liver transplantation (LT) recipients. A total of 18 patients who underwent endovascular management of PV via percutaneous transhepatic (n = 8) and transsplenic (n = 10) access were enrolled. Transsplenic access was chosen if the spleen was located in a normal position, the splenic vein (SpV) was preserved, and the target lesion did not involve confluence of the superior mesenteric and SpVs. Accessibility of the percutaneous transsplenic puncture was confirmed via ultrasound (US) in the angiography suite. All procedures were performed under local anesthesia. Percutaneous transhepatic or transsplenic access was performed using a 21-gauge Chiba needle under US and fluoroscopic guidance, followed by balloon angioplasty, stent placement, or variceal embolization. The access tract was embolized using coils and a mixture (1:2) of glue and ethiodized oil. Transhepatic or transsplenic access was successfully achieved in all patients. A total of 12 patients underwent stent placement; 3 had balloon angioplasty only; 2 had variceal embolization only; and 1 had variceal embolization followed by successful stent placement. Regarding major complications, 1 patient experienced a SpV tear with extravasation during transsplenic balloon angioplasty, which was successfully managed using temporary balloon inflation, followed by transfusion. Clinical success was achieved in 9 of 11 (82%) patients who exhibited clinical manifestations. The remaining 7 patients who underwent prophylactic endovascular management were healthy. In conclusion, endovascular management of PV via percutaneous transsplenic access is a relatively safe and effective alternative that does not damage the liver grafts of LT recipients. Liver Transplantation 23 1133-1142 2017 AASLD. © 2017 by the American

  6. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  7. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  8. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  9. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  10. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  12. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  13. Emergency and elective implantation of covered stent systems in iatrogenic arterial injuries

    International Nuclear Information System (INIS)

    Goltz, J.P.; Kickuth, R.; Bastuerk, P.; Hoppe, H.; Triller, J.

    2011-01-01

    Purpose: To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury. Materials and Methods: Between 03/1998 and 12/2009, 31 patients underwent selective covered stent implantation after iatrogenic arterial injury. 12/31 of these patients (38.7 %) were hemodynamically unstable. Six different endovascular covered stent types were utilized. The primary endpoints of this study were technical and clinical success and rates of minor and major complications. Results: Initial angiograms demonstrated active extravasation in 19 (61.3 %) patients and pseudoaneurysms in 12 (38.7 %) patients. The following sites of bleeding origin were detected: axillary artery, subclavian artery, common iliac artery, external iliac artery, internal iliac artery, common femoral artery, superficial femoral artery, popliteal and fibular artery, femoro-popliteal and popliteo-crural bypasses, common hepatic artery, aberrant hepatic artery, cystic and gastroduodenal artery. In all patients bleeding was effectively controlled by covered stent implantation resulting in an immediate technical success of 100 %. Clinical success attributed to covered stent implantation was documented in 30 of the 31 patients (96.8 %). Major complications included death in four patients (11.1 %), acute thrombosis with arm ischemia in one patient (2.8 %) and stent fracture with associated pseudoaneurysm in another patient (2.8 %). In 2/31 patients (6.5 %) covered stent failure was detected and successfully treated by implantation of a second covered stent. Conclusion: Emergency and elective implantation of covered stents may be used for minimally invasive and effective management of iatrogenic arterial injury. (orig.)

  14. Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries

    International Nuclear Information System (INIS)

    Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong

    2000-01-01

    Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter

  15. Technique, Complication, and Long-Term Outcome for Endovascular Treatment of Iliac Artery Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri

    2010-01-01

    The aim of this study was to report technical details, procedure-related complications, and results of endovascular treatment in chronic iliac artery occlusion. Between 2001 and 2008, endovascular treatments of 127 chronic iliac artery occlusions in 118 patients (8 women and 110 men; mean age, 59 years) were retrospectively reviewed. The study was based on Ad Hoc Committee on Reporting Standards (Society for Vascular Surgery/International Society for Cardiovascular Surgery Standards). All occlusions were treated with stent placement with or without preliminary balloon angioplasty. Kaplan-Meier estimators were used to determine patency rates. Univariate and multivariate analyses were performed to determine variables affecting successful recanalization, major complications, early stent thrombosis (≤30 days), and primary and secondary patency rates. Initial technical success was achieved in 117 (92%) procedures. Successful recanalization was obtained by antegrade approach in 69 of 77 (90%) procedures and by retrograde approach in 52 of 105 (50%) procedures (p < 0.001). Complications were encountered in 28 (24%) patients [minor in 7 patients (6%) and major in 22 patients (19%)]. One death occurred in the operative period secondary to iliac artery rupture. Early stent thrombosis was seen in eight (7%) patients. Presence of critical limb ischemia (p = 0.03), subintimal recanalization (p = 0.03), and major complication (p = 0.02) were the independent predictors of early stent thrombosis on multivariate analysis. Primary and secondary patency rates at 5 years were 63 and 93%, respectively. Presence of critical limb ischemia, TASC type C iliac lesions, combined occlusions of both common and external iliac arteries, and major complications were associated with decreased patency rates on univariate analysis, whereas these factors were not independent predictors of stent patency on multivariate analysis. In conclusion, endovascular treatment of iliac artery occlusion has a

  16. On the Mechanical Properties and Microstructure of Nitinol forBiomedical Stent Applications

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Scott W. [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    This dissertation was motivated by the alarming number of biomedical device failures reported in the literature, coupled with the growing trend towards the use of Nitinol for endovascular stents. The research is aimed at addressing two of the primary failure modes in Nitinol endovascular stents: fatigue-crack growth and overload fracture. The small dimensions of stents, coupled with their complex geometries and variability among manufacturers, make it virtually impossible to determine generic material constants associated with specific devices. Instead, the research utilizes a hybrid of standard test techniques (fracture mechanics and x-ray micro-diffraction) and custom-designed testing apparatus for the determination of the fracture properties of specimens that are suitable representations of self-expanding Nitinol stents. Specifically, the role of texture (crystallographic alignment of atoms) and the austenite-to-martensite phase transformation on the propagation of cracks in Nitinol was evaluated under simulated body conditions and over a multitude of stresses and strains. The results determined through this research were then used to create conservative safe operating and inspection criteria to be used by the biomedical community for the determination of specific device vulnerability to failure by fracture and/or fatigue.

  17. Acute vasculitis after endovascular brachytherapy

    International Nuclear Information System (INIS)

    Fajardo L-G, Luis F.; Prionas, Stavros D.; Kaluza, Grzegorz L.; Raizner, Albert E.

    2002-01-01

    Purpose: Angioplasty effectively relieves coronary artery stenosis but is often followed by restenosis. Endovascular radiation (β or γ) at the time of angioplasty prevents restenosis in a large proportion of vessels in swine (short term) and humans (short and long term). Little information is available about the effects of this radiation exposure beyond the wall of the coronary arteries. Methods and Materials: Samples were obtained from 76 minipigs in the course of several experiments designed to evaluate endovascular brachytherapy: 76 of 114 coronary arteries and 6 of 12 iliac arteries were exposed to endovascular radiation from 32 P sources (35 Gy at 0.5 mm from the intima). Two-thirds of the vessels had angioplasty or stenting. The vessels were systematically examined either at 28 days or at 6 months after radiation. Results: We found an unexpected lesion: acute necrotizing vasculitis in arterioles located ≤2.05 mm from the target artery. It was characterized by fibrinoid necrosis of the wall, often associated with lymphocytic exudates or thrombosis. Based on the review of perpendicular sections of tissue samples, the arterioles had received between 6 and 40 Gy. This arteriolar vasculitis occurred at 28 days in samples from 51% of irradiated coronary arteries and 100% of irradiated iliac arteries. By 6 months, the incidence of acute vasculitis decreased to 24% around the coronary arteries. However, at that time, healing vasculitis was evident, often with luminal narrowing, in 46% of samples. Vasculitis was not seen in any of 44 samples from unirradiated vessels (0%) and had no relation to angioplasty, stenting, or their sequelae. This radiation-associated vasculitis in the swine resembles the localized lymphocytic vasculitis that we have reported in tissues of humans exposed to external radiation. On the other hand, it is quite different from the various types of systemic vasculitis that occur in nonirradiated humans. Conclusion: Endoarterial brachytherapy

  18. Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients

    Directory of Open Access Journals (Sweden)

    Gussmann, Andreas

    2006-04-01

    Full Text Available Methods: 21 patients (17 men, 4 women; mean age 66.1 years, range 29-90 years with 15 true aneurysms, and 6 type B-dissections were treated by implantation of a TalentTM Endoluminal Stentgraft System from February 2000 to July 2003. In 3 cases it was necessary to overstent the left subclavian artery, in 1 case to overstent the left common carotid. Results: 2 patients (9.5% died during the first 30 days (1 myocardial infarction, 1 pneumonia. Two patients (9.5% suffered from cerebral ischemia and needed revascularisation. No paraplegia, no stroke occurred. One endoleak required additional stenting. No patient needed conversion. Follow-up, average 25.4 months (range 0-39, was 100% complete. During this another two patients died of myocardial infarction i.e. 9.5% (the above mentioned endoleak, but no late migration were detected in the remaining patients. In all cases the graft lumen stayed patent. Conclusions: Treatment of descending thoracic aortic aneurysm with an endovascular approach has acceptable mortality and morbidity-rates even in high risk patients. Procedural overstenting of the subclavian artery requires subclavian revascularisation in a minority of cases.

  19. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  20. Endovascular Procedures in Treatment of Infrapopliteal Arterial Occlusive Disease: Single Center Experience With 69 Infrapopliteal Procedures.

    Science.gov (United States)

    Janko, Pasternak J; Nebojsa, Budakov B; Andrej, Petres V

    2018-03-01

    Peripheral arterial occlusive disease (PAD) includes acute and chronic disorders of the blood supply as a result of obstruction of blood flow in the arteries of the limb. Treatment of PAD can be conservative, surgical and endovascular. Percutaneous transluminal angioplasty with or without stenting has become a recognized method, which is increasingly used in treatment of arterial occlusive disease. This study aimed to determine early results of endovascular treatment of critical limb ischemia (CLI) patients with infrapopliteal lesions. The study included 69 patients (46 men; mean age 65 years, range 38-84) with CLI (class 4 to 6 according to Rutherford). The primary study endpoints were absence of major amputation of the target limb at 6 months and occurance of local and systemic complications specifically related to use of endovascular treatment. Major amputation was avoided in 61 patients. Through 6 months, 6 patients underwent additional revascularization. One local complication (clinicaly significant dissection of popliteal artery) occurred, and it was resolved by stent implantation. There were no cases of systemic complications and death during the follow-up period. Rates of major amputation were 12.3% for diabetics versus 8.3% for non-diabetics. Our data showed that endovascular treatment of infrapopliteal disease is an effective and safe treatment in patients experiencing CLI, provides high limb preservation and low complication rates. Study outcomes support endovascular treatment as a primary option for patients experiencing CLI due to below the knee (BTK) occlusive disease. © 2018 The Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  1. Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report.

    Science.gov (United States)

    Conrad, Marcelo D; Brasiliense, Leonardo B C; Richie, Alexa N; Hanel, Ricardo A

    2014-05-01

    Many endovascular techniques have been described in recent years for the management of wide necked aneurysms. The Y stent assisted technique has been generally used for coil embolization of wide necked bifurcation aneurysms. This technique was first described for the treatment of basilar tip aneurysms in combination with several different devices, demonstrating encouraging results. We report the results of the first two cases of wide necked basilar tip aneurysms treated with Y stent assisted coil embolization using a new low profile visible intraluminal stent (LVIS Jr; MicroVention, Tustin, California, USA) delivered through a 0.017 inch microcatheter. We also reviewed the literature comparing other endovascular techniques (coiling alone, stent assisted coiling, and Y stent assisted coiling) for wide necked aneurysms. The LVIS Jr device offers a new option for the treatment of these challenging lesions, with clear advantages over currently available intracranial stents. Larger series and long term results are needed to confirm the applicability and durability of this technique/technology.

  2. The fluoro-less and contrast-less peripheral endovascular intervention: Halfway there

    Energy Technology Data Exchange (ETDEWEB)

    Ephrem, Georges, E-mail: g.ephrem@gmail.com; Garikipati, Sireesha; Hanson, Ivan D.

    2016-09-15

    Introduction: Percutaneous endovascular revascularization requires the use of fluoroscopic guidance and radiopaque contrast. We present a successful intervention without the use of iodinated contrast. Case: A 92-year-old man with dry gangrene involving the second and fourth left toes had acute on chronic kidney injury. Arterial duplex showed severe stenosis in bilateral superficial femoral arteries (SFAs). Fluoroscopic and ultrasound guidance and intravascular imaging were used to avoid iodinated contrast. After right to left femoral crossover, the entire left SFA was imaged with ultrasound. The lesion was delineated with radiopaque measuring tapes then wired. Near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) imaging were performed. Points of interest were correlated with corresponding radiopaque markings on the ruler. Stenting and post-dilation resulted in complete stent expansion and no evidence of dissection by IVUS. The total procedure time was 113 min and the total radiation dose 813 mGy. The day after the procedure, there was a palpable dorsalis pedis pulse. He was discharged to inpatient rehabilitation on dual antiplatelet therapy. Discussion: Contrast and radiation continue to limit the feasibility of endovascular angiography and intervention. Carbon dioxide (CO2) digital subtraction angiography is an alternative for these patients but has several disadvantages. Previously proposed projects demonstrated the real potential of performing endovascular peripheral intervention without fluoroscopy or contrast. Conclusion: This case is a clear demonstration of a successful use of a combination of fluoroscopy, ultrasonography and intravascular imaging to achieve a successful endovascular intervention to treat critical limb ischemia, without the use of iodinated contrast.

  3. Endovascular Management of Infected Femoral Artery Pseudoaneurysms in High-Risk Patients: A Case Series

    Energy Technology Data Exchange (ETDEWEB)

    D’Oria, Mario, E-mail: mario.doria88@outlook.com; Sgorlon, Giada; Calvagna, Cristiano; Zamolo, Francesca; Chiarandini, Stefano; Adovasio, Roberto; Griselli, Filippo [University Hospital of Cattinara, Vascular and Endovascular Surgery Unit (Italy)

    2017-04-15

    We report our experience with the urgent treatment of two high-risk patients with infected femoral artery pseudoaneurysms (IFAPs) with the placement of a self-expandable covered stent (SECS). In both cases, there was no perioperative mortality and the aneurysm exclusion was successful without early or late stent thrombosis/stent fracture nor acute or chronic limb ischemia or limb loss. There was no recurrence of local or systemic infection during the follow-up period. Endovascular therapy represents a feasible treatment option for IFAPs in those patients for whom the risk of open surgical repair would be prohibitive, especially under urgent circumstances.

  4. New expandable metallic stents: An experimental study in vessels of dogs

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Jung Min; Chung, Jin Young; Chung, Gyung Ho; Kim, Bog Yi; Kuh, Ja Houng

    1992-01-01

    Three-types of expandable metallic stents were constructed to evaluate the differences between the stents: one, formed in a cylindrical zigzag pattern wth stainless steel wire (Gianturco stent), another, made by coating the Gianturco stent with silicone rubber (Silicone stent), the third, made by coating the Gianturco stent with 24 carat gold (Gold stent) for tissue acceptance. A total of 69 stents (each 23 stents of Gianturco, Silicone, and Gold stents) of 8-12 mm in diameter and 20 mm long were placed into normal abdominal aorta, inferior vena cava and lilac artery of nine adults dogs for 2 weeks to 11 months. It was more difficult to introduce Silicone stent into an introducing sheath than Gianturco or Gold stent due to the thickness of silicone rubber. Four Gianturco stents and three Silicone stents showed migration but Gold stent did not. Luminal narrowing or occlusion was noted in 3 Silicone stents. In 2 Gianturco stents, and in 1 Gold stent. Neointimal proliferation over the stent wires was more rapid and even in Gold stent than Silicone or Gianturco stent. Although further study is needed, Gold stent seems to be better than Gianturco or Silicone stent as an endovascular graft material

  5. New expandable metallic stents: An experimental study in vessels of dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Lee, Jung Min; Chung, Jin Young; Chung, Gyung Ho; Kim, Bog Yi; Kuh, Ja Houng [Chunbuk National University Medical School, Chunju (Korea, Republic of)

    1992-07-15

    Three-types of expandable metallic stents were constructed to evaluate the differences between the stents: one, formed in a cylindrical zigzag pattern wth stainless steel wire (Gianturco stent), another, made by coating the Gianturco stent with silicone rubber (Silicone stent), the third, made by coating the Gianturco stent with 24 carat gold (Gold stent) for tissue acceptance. A total of 69 stents (each 23 stents of Gianturco, Silicone, and Gold stents) of 8-12 mm in diameter and 20 mm long were placed into normal abdominal aorta, inferior vena cava and lilac artery of nine adults dogs for 2 weeks to 11 months. It was more difficult to introduce Silicone stent into an introducing sheath than Gianturco or Gold stent due to the thickness of silicone rubber. Four Gianturco stents and three Silicone stents showed migration but Gold stent did not. Luminal narrowing or occlusion was noted in 3 Silicone stents. In 2 Gianturco stents, and in 1 Gold stent. Neointimal proliferation over the stent wires was more rapid and even in Gold stent than Silicone or Gianturco stent. Although further study is needed, Gold stent seems to be better than Gianturco or Silicone stent as an endovascular graft material.

  6. Endovascular aneurysm exclusion along a femorodistal venous bypass in active Behçet's disease.

    Science.gov (United States)

    Gretener, Silvia B; Do, Dai-Do; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg; Birrer, Manuela

    2002-10-01

    To report the endovascular repair of dual aneurysms along a femorodistal venous bypass graft in a patient with Behçet's disease. A 55-year-old man of middle European ancestry with Behçet's disease had dual aneurysms evolve along the proximal segment of a femorodistal venous bypass that had been implanted 2.5 years earlier for recurrent false aneurysm formation. Owing to the lack of suitable venous conduits and the active nature of the disease, the aneurysms were successfully excluded with overlapping Hemobahn and Jostent endografts; the immunosuppressive therapy was intensified. Rupture of the aneurysms was successfully prevented, but the stent-grafts thrombosed 6 weeks later owing to exacerbation of the underlying disease. Endovascular exclusion of aneurysm in venous bypass grafts in Behçet's disease is feasible. Although the stent-grafts thrombosed, they did prevent rupture of the aneurysms.

  7. Endovascular aortic graft infection resulting in retroperitoneal abscess: report of a case

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2010-06-01

    Full Text Available Infection is a rare complication of aortoiliac endovascular procedures, with an incidence inferior to 0.5%, and it may result in a retroperitoneal abscess potentially evolving to sepsis and gastrointestinal bleeding. In more than 50% of cases endovascular aortoiliac prosthetic grafts infection occur months or years after the procedure. The growing number of endovascular procedures, and as the actually midterm follow up in most cases, septic sequelae will no doubt continue to occur with increased frequency and may represent an emerging problem in the ED for the emergency physician. Endovascular graft infection begins with unspecific clinical manifestations. An high index of suspicion in any patient with an aortic stent graft presenting prolonged or recurrent fever and or abdominal or back pain and a low threshold for obtaining CT scan should increase the clinician’s ability to make a timely diagnosis in the ED setting.

  8. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  9. Miscellaneous Endovascular Treatment of Ruptured Hepatic Artery Pseudoaneurysms after Pylorus Preserving Pancreaticoduodenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University Medical Center, Catholic of Daegu University School of Medicine, Daegu (Korea, Republic of); Ahn, Eun Joung; Kim, See Hyung; Kim, Young Hwan [Dept. of Radiology, Keimyung University Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-03-15

    To assess the feasibility and safety of the endovascular treatment of ruptured hepatic artery pseudoaneurysms after pylorus preserving pancreaticoduodenectomy (PPPD). Thirteen patients with hepatic artery pseudoaneurysm after PPPD were enrolled. Various endovascular techniques were used depending on the sites and morphologies of the pseudoaneurysms. Five cases were treated by coil embolization, five with stent-graft, one by thrombin injection and coil embolization, one with stent-graft and coil embolization, and one with N-butyl cyanoacrylate (NBCA) injection. Computed tomography scans and liver function test were performed after the procedures. Pseudoaneurysm exclusion and bleeding cessation was achieved in all patients. In four patients that underwent coil or NBCA embolization of the hepatic artery, aspartate transaminase (AST) and alanine transaminase (ALT) were markedly elevated. Two of these four patients with narrowing of the portal vein due to surrounding hematoma died of hepatic infarction or hepatic abscess. In other nine patients, AST and ALT were unchanged. In the 11 surviving patients, normal hepatic function and complete pseudoaneurysm disappearance were achieved during follow-up. Endovascular treatment of ruptured hepatic artery pseudoaneurysms can be considered as a feasible and safe method. However, complete occlusion of the hepatic artery with coils should be avoided in patients with inadequate portal flow.

  10. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  11. Revascularização endovascular infrainguinal: fatores determinantes para a perviedade Endovascular infrainguinal revascularization: predictive factors for patency

    Directory of Open Access Journals (Sweden)

    Felipe Nasser

    2009-03-01

    Full Text Available Contexto: A terapia endovascular tem avançado muito como tratamento para a doença arterial oclusiva infrainguinal, principalmente com o desenvolvimento dos materiais e dos stents autoexpansíveis de nitinol. Objetivo: Avaliar os resultados e os fatores determinantes da angioplastia fêmoro-poplítea em pacientes portadores de isquemia de membros inferiores. Métodos: Foram tratados, através de angioplastia com ou sem stent, 114 pacientes, e acompanhados por um período médio de 12 meses. A média de idade foi de 66 anos; 53% eram do sexo feminino; 23,7% eram portadores de claudicação incapacitante; 8,8%, de dor isquêmica de repouso; e 67,5%, de lesão trófica. As lesões foram classificadas segundo o TransAtlantic Inter-Society Consensus II em A (53%, B (34%, C (5% e D (9%. Resultados: A análise angiográfica do leito distal mostrou uma média de 1,4±1,0 artérias infrapoplíteas pérvias. O sucesso inicial foi de 97%. No seguimento de 1, 6, 12 e 24 meses, a perviedade primária foi de 94, 78, 48 e 31%, e a primária assistida, de 94, 84, 73 e 61%, respectivamente (p = 0,005. O leito distal pobre e a presença de diabetes melito foram associados a uma menor perviedade primária (p = 0,01, enquanto a extensão da lesão não influenciou os resultados. As taxas de salvamento de membro em 6, 12 e 24 meses foram de 95, 90 e 90%, respectivamente. Conclusões: A extensão das lesões tratadas não foi um fator determinante em nossa casuística para o menor sucesso da angioplastia, o que pode sugerir que as indicações para o tratamento endovascular possam ser ampliadas para pacientes com lesões TransAtlantic Inter-Society Consensus II C/D.Background: Endovascular techniques have undergone major advances with regard to the treatment of infrainguinal arterial occlusive disease, mainly as a result of development of new devices and self-expanding nitinol stents. Objective: To evaluate the results and determinant factors of femoropopliteal

  12. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Hans, F.J.; Thiex, R.; Gilsbach, J.M.; Krings, T.; Moeller-Hartmann, W.; Dreeskamp, H.; Stein, K.P.; Meetz, A.; Thron, A.; Pfeffer, J.; Scherer, K.; Brunn, A.

    2003-01-01

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  13. Delayed pan-hypopituitarism as a complication following endovascular treatment of bilateral internal carotid artery aneurysms. A case report and review.

    Science.gov (United States)

    Hall, Jonathan; Caputo, Carmela; Chung, Carlos; Holt, Michael; Wang, Yi Yuen

    2015-04-01

    Pan-hypopituitarism has been reported in patients who are subsequently found to have a cerebral aneurysm and there have been reports of pituitary dysfunction immediately following both surgical and endovascular treatment. The authors report a rare case of delayed pan-hypopituitarism following endovascular treatment of bilateral internal carotid artery aneurysms with coil embolisation and flow-diverting stents.

  14. Endovascular Exclusion of Renal Artery Aneurysm

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Rohr, Nils

    2005-01-01

    A patient who was operated for an abdominal aortic aneurysm 7 years earlier presented with recently discovered iliac and renal artery aneurysms. The renal artery had an angulation of 90 o , but the aneurysm was successfully excluded using a covered vascular stent graft placed over an extrastiff guidewire. Even in cases of complex anatomy of a renal aneurysm, endovascular treatment should be considered. With development of more flexible and low-profile endoprosthesis with accurate deployment, these have become more usable

  15. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  16. Endovascular Management of Acute Bleeding Arterioenteric Fistulas

    International Nuclear Information System (INIS)

    Leonhardt, Henrik; Mellander, Stefan; Snygg, Johan; Loenn, Lars

    2008-01-01

    The objective of this study was to review the outcome of endovascular transcatheter repair of emergent arterioenteric fistulas. Cases of abdominal arterioenteric fistulas (defined as a fistula between a major artery and the small intestine or colon, thus not the esophagus or stomach), diagnosed over the 3-year period between December 2002 and December 2005 at our institution, were retrospectively reviewed. Five patients with severe enteric bleeding underwent angiography and endovascular repair. Four presented primary arterioenteric fistulas, and one presented a secondary aortoenteric fistula. All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed immediate further open surgery. There were no procedure-related major complications. Mean hospital stay after the initial endovascular intervention was 19 days. Rebleeding occurred in four patients (80%) after a free interval of 2 weeks or longer. During the follow-up period three patients needed reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered

  17. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    International Nuclear Information System (INIS)

    Huet, Nicolas; Rodiere, Mathieu; Badet, Michel; Michoud, Marie; Brichon, Pierre-Yves; Ferretti, Gilbert; Thony, Frédéric

    2016-01-01

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  18. Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound

    Energy Technology Data Exchange (ETDEWEB)

    Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France); Badet, Michel, E-mail: michel.badet@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, site de Chambéry, Intensive Care Unit (France); Michoud, Marie, E-mail: marie.michoud@ch-chambery.fr [Centre Hospitalier Métropôle Savoie, Site de Chambéry, Department of Radiology (France); Brichon, Pierre-Yves, E-mail: pybrichon@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Thoracic and Vascular Surgery (France); Ferretti, Gilbert, E-mail: gferretti@chu-grenoble.fr; Thony, Frédéric, E-mail: fthony@chu-grenoble.fr [Hôpital Universitaire de Grenoble and Université Grenoble Alpes, Department of Radiology and Medical Imaging (France)

    2016-05-15

    We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.

  19. Endovascular Mechanical Thrombectomy in Basilar Artery Occlusion: Initial Experience

    Science.gov (United States)

    Park, Bum-Soo; Kwon, Hyon-Jo; Choi, Seung-Won; Kim, Seon-Hwan; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun

    2013-01-01

    Objective This study was conducted to assess the efficacy and safety of endovascular mechanical thrombectomy (EMT) for patients diagnosed with basilar artery (BA) occlusion. Materials and Methods We retrospectively analyzed clinical and imaging data of 16 patients diagnosed with BA occlusion who were treated with endovascular intervention from July 2012 to February 2013. Direct suction using the Penumbra system and thrombus retrieval by the Solitaire stent were the main endovascular techniques used to restore BA flow. The outcomes were evaluated based on rate of angiographic recanalization, rate of improvement of National Institutes of Health Stroke Scale (NIHSS) score, rate of modified Rankin Scale (mRS) at discharge and after 3 months, and rate of cerebral hemorrhagic complications. Successful recanalization was defined as achieving Thrombolysis In Cerebral Infarction (TICI) of II or III. Results Sixteen patients received thrombectomy. The mean age was 67.8 ± 11 years and the mean NIHSS score was 12.3 ± 8.2. Eight patients treated within 6 hours of symptom onset were grouped as A and the other 8 patients treated beyond 6 hours (range, 6-120) were grouped as B. Successful recanalization was met in six patients (75%) for group A and 7 (87.5%) for group B. Favorable outcome occurred in 4 patients (50%) for group A and 5 (62.5%) for group B. Conclusion Our study supports the effectiveness and safety of endovascular mechanical thrombectomy in treating BA occlusion even 6 hours after symptom onset. PMID:24167791

  20. Direct stent puncture technique for intraluminal stent recanalization in the superficial femoral and popliteal arteries in-stent occlusion: Outcomes from a prospective clinical analysis of diabetics with critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Palena, Luis Mariano, E-mail: marianopalena@hotmail.com; Manzi, Marco

    2013-07-15

    Purpose: To evaluate the efficacy and safety of “Direct Stent Puncture” technique for intraluminal stent recanalization in the femoro-popliteal segments. Methods and Materials: A cohort of diabetics who had symptomatic in-stent occlusion of the superficial femoral or popliteal arteries underwent endovascular recanalization. After antegrade failure, direct stent puncture technique was performed. The primary end-point was to efficacy assessment, intended as technical success and clinical improvement. The secondary end-point was safety assessment, intended as free of complication rate. Results: Fifty-four patients (37 men; 73.6 ± 8.5 years) underwent direct stent puncture technique, after several unsuccessful antegrade attempts to cross the occluded stent. Technical success for intraluminal stent recanalization was achieved in 53/54 (98.2%) of cases and failed in 1/54 (1.8%). Clinical improvement was obtained in 51/54 (94.4%) of cases, with regression of the clinical symptoms and improvement of the TcPO{sub 2}, from 3 ± 18 mmHg to 43 ± 11 mmHg after 15 days (p < 0.001). Free of complications rate was 92.5%. In 2/54 (3.7%) of cases distal embolization occurred, in 1/54 (1.9%) case a sudden vessel thrombosis was diagnosed after 12 hours and in 1/54 (1.9%) case hematoma at the stent puncture site was observed. Conclusions: Direct Stent Puncture technique is an efficacy and safety option for intraluminal stent recanalization in the femoro-popliteal segment in-stent occlusion.

  1. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  2. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  3. PTA and Stenting of Benign Venous Stenoses in the Pelvis: Long-Term Results

    International Nuclear Information System (INIS)

    Wohlgemuth, Walter A.; Weber, Hermann; Loeprecht, Henning; Tietze, Wolfram; Bohndorf, Klaus

    2000-01-01

    Purpose: To provide follow-up data on endovascular intervention for venous stenoses in the pelvis.Methods: Between 1985 and 1995, 35 patients presented with 42 stenoses of the pelvic veins after operative thrombectomy and creation of an arteriovenous fistula, combined with intraoperative venous angioscopy. All patients underwent angioplasty and, if unsuccessful, percutaneous insertion of an endovascular stent (n = 7).Results: Angioplasty with and without endovascular stenting was technically successful in 34 of 35 patients (97%). Average length of the stenoses was 20.6 mm (range 10-90 mm), average diameter before dilation 4.1 mm (range 2-6 mm), and average diameter after dilation 10.1 mm (range 5-18 mm). Intraoperative angioscopy showed pathologic findings (intimal laceration or residual thrombotic material) in 14 patients. After an average follow-up period of 4.13 years, 24 (69%) patients had patent veins. The difference in the primary patency rate between patients with angioscopically abnormal veins (6 of 14 patients, corresponding to a patency rate of 43%) and patients with angioscopically normal veins after thrombectomy (18 of 21 patients, corresponding to a patency rate of 86%) was statistically significant (p < 0.01, log rank test).Conclusions: Percutaneous transluminal angioplasty and/or stenting are good treatment modalities for pelvic vein stenosis following surgical thrombectomy. Angioscopically abnormal veins have a poorer long-term patency, regardless of the type of intervention

  4. Treatment of pseudoaneurysms with stent-graft: preliminary experience in 12 cases

    International Nuclear Information System (INIS)

    Liao Denghui; Ye Caisheng; Li Songqi; Ye Runyi; Chang Guangqi; Chen Wei; Li Xiaoxi; Wang Shenming

    2012-01-01

    Objective: To asses the clinical effect of stent-graft in the treatment of pseudoaneurysms. Methods: During the period from March 2008 to June 2011, 86 patients with pseudoaneurysms were admitted to the hospital, of whom stent-graft implantation was carried out in 12. The pseudoaneurysms were located at the thoracic aorta (n=4), abdominal aorta (n=3), common carotid artery (n=3), internal carotid artery (n=1) and right subclavian artery (n=1). All the patient were followed up for 5-43 months. The clinical results were analyzed. Results: The technical success rate for stent delivery was 100%. The pseudoaneurysms was immediately isolated after the procedure in all 12 cases. After endovascular exclusion with stent-graft, no leakage occurred and the blood flow distal to the parent artery was normal. All patients were followed up for a mean period of 23.5 months except one who lost in touch with the authors. One patient with coexisting Behcet's disease died of massive bleeding due to abdominal aortic rupture four months after operation. The other patients were in good clinical condition, and no complications such as stent stenosis, displacement, internal leakage etc. were observed in the follow-up period. Conclusion: The implantation of stent-graft has satisfactory short-term effect in treating pseudoaneurysms, although its long-term efficacy needs to be further observed. (authors)

  5. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  6. The INNOVATION Trial: four-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System for endovascular repair.

    Science.gov (United States)

    Pratesi, Giovanni; Pratesi, Carlo; Chiesa, Roberto; Coppi, Gioacchino; Scheinert, Dierk; Brunkwall, Jan S; van der Meulen, Stefaan; Torsello, Giovanni

    2017-10-01

    This paper reports the 4-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System (Cordis Corp., Milpitas, CA, USA), an ultra-low-profile device for the treatment of abdominal aortic aneurysms. The INNOVATION Trial is the prospective, first-in-human, multicenter trial to evaluate the safety and effectiveness of the INCRAFT® System. Patients underwent annual clinical and computed tomography angiography examination as part of the study protocol. The INCRAFT® AAA Stent-Graft System is a customizable tri-modular design, with an ultra-low profile (14-Fr) delivery system. Patient were treated under approved protocol, the prescribed clinical and imaging follow-up at annually through 5 years. Results analyzed and adjudicated by a clinical events committee, independent core laboratory, and a data safety and monitoring board. This manuscript reports results through 4 years of follow-up. A total of 60 patients were enrolled in the trial, all of whom were successfully treated. Follow-up rates at 1 and 4 years were 93% (56/60) and 85% (51/60), respectively. All-cause mortality at 4 years was 17.6% and no death was AAA-, device-, or procedure-related. The secondary reintervention rate at 1 year was 4.6%, primarily the result of stent thrombosis. In total, 10 patients required 13 post-procedure interventions within 4-years of follow-up (2 to repair a type I endoleak, 4 to repair a type II endoleak, 1 for stent thrombosis, 1 for renal stenosis, 1 for aneurysm enlargement, 2 for limb migration and 2 for prosthesis stenosis or occlusion). There were 4 cases (10%) of aneurysm enlargement reported at the 4 year follow-up. At 4 years, 38 out of 39 patients were free from type I and III endoleaks. There were no proximal type I or type III endoleaks at 4-year follow-up. Core laboratory evaluation of the postoperative imaging studies indicated absence of endograft migration while a single fracture was demonstrated without any clinical sequelae. The INCRAFT® AAA Stent

  7. [Microscopic investigation of vessel wall after endovascular catheter atherectomy].

    Science.gov (United States)

    Tsygankov, V N; Khovalkin, R G; Chekmareva, I A; Kalinin, D V; Filippova, E M

    2014-01-01

    Endovascular target catheter atherectomy (ETCA) - method of artery patency allowing to obtain occlusion substrate. Given the high destructive effect of atherectome's elements on tissue the objective was determination possibility of histological and electron microscopic investigation of this substrate after atherectomy. The research included 8 patients who underwent ETCA of legs arteries. It was observed substrate removal from broken stent in 1 case. 2 of 8 patients had diabetes. Obtained substrate was available for histological and electron microscopic investigation. Atherosclerosis was confirmed in all cases. It was not observed substrate significant morphological changes in patients with presence or absence of diabetes. Microscopic investigation of substrate from broken stent shows pronounced development of granulation tissue that was regarded as special form of reparative regeneration. Finding internal elastic membrane during microscopic investigation in some cases proves radical intervention. The authors consider that microscopic investigation of substrate after ETCA may be used for diagnosis verification, thorough analysis of morphological changes in lesion area and radicalism of atherectomy.

  8. Stroke Neurologist's Perspective on the New Endovascular Trials.

    Science.gov (United States)

    Grotta, James C; Hacke, Werner

    2015-06-01

    Before December 2014, the only proven effective treatment for acute ischemic stroke was recombinant tissue-type plasminogen activator (r-tPA). This has now changed with the publication of the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN), Endovascular Treatment for Small Core and Anterior Circulation Proximal Occlusion With Emphasis on Minimizing CT to Recanalization Times (ESCAPE), Extending the Time for Thrombolysis in Emergency Neurological Deficits--Intra-Arterial (EXTEND IA), Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment Trial (SWIFT PRIME), and Randomized Trial of Revascularization With the Solitaire FR Device Versus Best Medical Therapy in the Treatment of Acute Stroke Due to Anterior Circulation Large Vessel Occlusion Presenting Within Eight Hours of Symptom Onset (REVASCAT) studies. We review the main results of these studies and how they inform stroke patient management going forward. The main take home points for neurologists are (1) intra-arterial thrombectomy is a potently effective treatment and should be offered to patients who have documented occlusion in the distal internal carotid or the proximal middle cerebral artery, have a relatively normal noncontrast head computed tomographic scan, severe neurological deficit, and can have intra-arterial thrombectomy within 6 hours of last seen normal; (2) benefits are clear in patients receiving r-tPA before intra-arterial thrombectomy; r-tPA should not be withheld if the patient meets criteria, and benefit in patients who do not receive r-tPA or have r-tPA exclusions requires further study; and (3) these favorable results occur when intra-arterial thrombectomy is performed in an endovascular stroke center by a coordinated multidisciplinary team that extends from the prehospital stage to the endovascular suite, minimizes time to recanalization, uses stent-retriever devices, and avoids general

  9. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Endovascular Treatment for Iliac Vein Compression Syndrome: a Comparison between the Presence and Absence of Secondary Thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Lou, Wen Sheng; Gu, Jian Ping; He, Xu; Chen, Liang; Su, Hao Bo; Chen, Guo Ping; Song, Jing Hua; Wang, Tao [Nanjing First Hospital Affiliated to Nanjing Medical University, Nanjing (China)

    2009-04-15

    To evaluate the value of early identification and endovascular treatment of iliac vein compression syndrome (IVCS), with or without deep vein thrombosis (DVT). Three groups of patients, IVCS without DVT (group 1, n = 39), IVCS with fresh thrombosis (group 2, n = 52) and IVCS with non-fresh thrombosis (group 3, n = 34) were detected by Doppler ultrasonography, magnetic resonance venography, computed tomography or venography. The fresh venous thrombosis were treated by aspiration and thrombectomy, whereas the iliac vein compression per se were treated with a self-expandable stent. In cases with fresh thrombus, the inferior vena cava filter was inserted before the thrombosis suction, mechanical thrombus ablation, percutaneous transluminal angioplasty, stenting or transcatheter thrombolysis. Stenting was performed in 111 patients (38 of 39 group 1 patients and 73 of 86 group 2 or 3 patients). The stenting was tried in one of group 1 and in three of group 2 or 3 patients only to fail. The initial patency rates were 95% (group 1), 89% (group 2) and 65% (group 3), respectively and were significantly different (p = 0.001). Further, the six month patency rates were 93% (group 1), 83% (group 2) and 50% (group 3), respectively, and were similarly significantly different (p = 0.001). Both the initial and six month patency rates in the IVCS patients (without thrombosis or with fresh thrombosis), were significantly greater than the patency rates of IVCS patients with non-fresh thrombosis. From the cases examined, the study suggests that endovascular treatment of IVCS, with or without thrombosis, is effective

  11. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  12. Self expandable polytetrafluoroethylene stent for carotid blowout syndrome.

    Science.gov (United States)

    Tatar, E C; Yildirim, U M; Dündar, Y; Ozdek, A; Işik, E; Korkmaz, H

    2012-01-01

    Carotid blowout syndrome (CBS) is an emergency complication in patients undergoing treatment for head and neck cancers. The classical management of CBS is the ligation of the common carotid artery, because suturing is not be possible due to infection and necrosis of the field. In this case report, we present a patient with CBS, in whom we applied a self-expandable polytetrafluoroethylene (PTFE) stent and observed no morbidity. Endovascular stent is a life-saving technique with minimum morbidity that preserves blood flow to the brain. We believe that this method is preferable to ligation of the artery in CBS.

  13. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  14. Retreatment and outcomes of recurrent intracranial vertebral artery dissecting aneurysms after stent assisted coiling: a single center experience.

    Directory of Open Access Journals (Sweden)

    Ying Song

    Full Text Available The retreatment of recurrent intracranial vertebral artery dissecting aneurysms (VADAs after stent assisted coiling (SAC has not yet been studied. The purpose of this study was to evaluate the strategies and outcomes for retreatment of recurrent VADAs after SAC.Between September 2009 and November 2013, six consecutive patients presenting with recurrent intracranial VADAs after SAC were enrolled in this study. They were all male with age ranging from 29 to 54 years (mean age, 46.2 years. The procedures of treatments and angiographic and clinical follow-up were reviewed retrospectively. Retreatment modalities were selected individually according to the characteristics of recurrence. The outcomes of retreatment were evaluated by angiographic and clinical follow-up.Six patients with recurrent intracranial VADAs after SAC were retreated, with second SAC in three patients, coil embolization, double overlapping stents placement and endovascular occlusion with aneurysm trapping in one patient, respectively. Immediate angiographic outcomes of retreatment were: complete occlusion in three patients, nearly complete occlusion in two patients, and contrast medium retention in dissecting aneurysm in one patient. All cases were technically successful. No complications related to endovascular procedures occurred. Angiographic follow-up was available in all five patients treated with second SAC or double overlapping stents, which was complete occlusion in four patients, obliteration of parent artery in one patient, showing no recurrence at 4-11 months (mean: 8.6 months. Clinical follow-up was performed in all six patients at 11-51 months after initial endovascular treatment and at 9-43 months after retreatment. The mRS of last clinical follow-up was excellent in five patients and mild disability in only one patient.Endovascular retreatment is feasible and effective for recurrent intracranial VADAs after SAC. Individualized strategies of retreatment should be

  15. Stroke prevention by endovascular treatment of carotid and vertebral artery dissections.

    Science.gov (United States)

    Moon, Karam; Albuquerque, Felipe C; Cole, Tyler; Gross, Bradley A; McDougall, Cameron G

    2017-10-01

    Endovascular intervention for cervical carotid artery dissection (CAD) and vertebral artery dissection (VAD) may be indicated in specific circumstances. To review our institutional experience with endovascular treatment of cervical dissections over the past 20 years to examine indications for treatment, interventional methods, and outcomes. Retrospective review of a prospectively maintained database to identify patients with extracranial dissection who underwent endovascular intervention between January 1996 and January 2016. Demographic data and details of procedures, outcomes, and complications were extracted. Of 116 patients [93 CAD, 23 VAD; mean age 44.9 years (range 5-76 years)], 104 underwent stent placement; 11, coil occlusion of the parent artery; and 1, stenting with contralateral vessel occlusion. The cohorts were well matched for age, sex, dissection etiology, and admission and follow-up modified Rankin Scale (mRS) scores. Patients with CAD had significantly more stent placements (p<0.001), failure of medical therapy (p=0.004), and interventions for enlarging pseudoaneurysms (p=0.01) or thromboembolic events (p=0.004). Patients with VAD had significantly more interventions for traumatic occlusion with recanalization (p<0.001). Dissections were spontaneous (n=67), traumatic (n=36), or iatrogenic (n=13). Traumatic dissections in patients with CAD were associated with poor admission mRS scores (p=0.01). Six of 67 (9.0%) patients with spontaneous dissection reported recent chiropractic manipulation. Mean follow-up was 3.5 years (range 1-146 months). Permanent morbidity/mortality was 3.4%, including two deaths. Over a follow-up period of 364 patient-years, 1 stroke occurred (0.27% per year). At last follow-up, 41 previously disabled patients [CAD, 31/93 (33.3%); VAD, 10/23 (43.5%)] were no longer disabled; no patient reported worsened disability. Patients with CAD and VAD differ significantly in presentation, indications for treatment, and treatment

  16. Emergency Stenting of a Ruptured Infected Anastomotic Femoral Pseudoaneurysm

    International Nuclear Information System (INIS)

    Klonaris, Chris; Katsargyris, Athanasios; Matthaiou, Alexandros; Giannopoulos, Athanasios; Tsigris, Chris; Papadopouli, Katerina; Tsiodras, Sotiris; Bastounis, Elias

    2007-01-01

    A 74-year-old man presented with a ruptured infected anastomotic femoral pseudoaneurysm. Due to severe medical comorbidities he was considered unsuitable for conventional surgical management and underwent an emergency endovascular repair with a balloon-expandable covered stent. The pseudoaneurysm was excluded successfully and the patient had an uneventful postoperative recovery with long-term suppressive antimicrobials. He remained well for 10 months after the procedure with no signs of recurrent local or systemic infection and finally died from an acute myocardial infarction. To our knowledge, emergency endovascular treatment of a free ruptured bleeding femoral artery pseudoaneurysm has not been documented before in the English literature. This case illustrates that endovascular therapy may be a safe and efficient alternative in the emergent management of ruptured infected anastomotic femoral artery pseudoaneurysms when traditional open surgery is contraindicated

  17. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  18. Mid-Term Outcomes of Endovascular Treatment for TASC-II D Femoropopliteal Occlusive Disease with Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Blanco, Álvaro, E-mail: atorres658@yahoo.es; Edo-Fleta, Gemma; Gómez-Palonés, Francisco; Molina-Nácher, Vicente; Ortiz-Monzón, Eduardo [Hospital Universitario Dr. Peset, Department of Angiology, Endovascular and Vascular Surgery (Spain)

    2016-03-15

    PurposeThe purpose of the study was to assess the safety and midterm effectiveness of endovascular treatment in Trans-Atlantic Inter-Society Consensus II (TASC-II) D femoropopliteal occlusions in patients with critical limb ischemia (CLI).MethodsPatients with CLI who underwent endovascular treatment for TASC-D de novo femoropopliteal occlusive disease between September 2008 and December 2013 were selected. Data included anatomic features, pre- and postprocedure ankle-brachial index, duplex ultrasound, and periprocedural complications. Sustained clinical improvement, limb salvage rate, freedom from target lesion revascularization (TLR), and freedom from target extremity revascularization (TER) were assessed by Kaplan–Meier estimation and predictors of restenosis/occlusion with Cox analysis.ResultsThirty-two patients underwent treatment of 35 TASC-D occlusions. Mean age was 76 ± 9. Mean lesion length was 23 ± 5 cm. Twenty-eight limbs (80 %) presented tissue loss. Seventeen limbs underwent treatment by stent, 13 by stent-graft, and 5 by angioplasty. Mean follow-up was 29 ± 20 months. Seven patients required major amputation and six patients died during follow-up. Eighteen endovascular and three surgical TLR procedures were performed due to restenosis or occlusion. Estimated freedom from TLR and TER rates at 2 years were 41 and 76 %, whereas estimated primary and secondary patency rates were 41 and 79 %, respectively.ConclusionsEndovascular treatment for TASC II D lesions is safe and offers satisfying outcomes. This patient subset would benefit from a minimally invasive approach. Follow-up is advisable due to a high rate of restenosis. Further follow-up is necessary to know the long-term efficacy of these procedures.

  19. Mechanical design of an intracranial stent for treating cerebral aneurysms.

    Science.gov (United States)

    Shobayashi, Yasuhiro; Tanoue, Tetsuya; Tateshima, Satoshi; Tanishita, Kazuo

    2010-11-01

    Endovascular treatment of cerebral aneurysms using stents has advanced markedly in recent years. Mechanically, a cerebrovascular stent must be very flexible longitudinally and have low radial stiffness. However, no study has examined the stress distribution and deformation of cerebrovascular stents using the finite element method (FEM) and experiments. Stents can have open- and closed-cell structures, and open-cell stents are used clinically in the cerebrovasculature because of their high flexibility. However, the open-cell structure confers a risk of in-stent stenosis due to protrusion of stent struts into the normal parent artery. Therefore, a flexible stent with a closed-cell structure is required. To design a clinically useful, highly flexible, closed-cell stent, one must examine the mechanical properties of the closed-cell structure. In this study, we investigated the relationship between mesh patterns and the mechanical properties of closed-cell stents. Several mesh patterns were designed and their characteristics were studied using numerical simulation. The results showed that the bending stiffness of a closed-cell stent depends on the geometric configuration of the stent cell. It decreases when the stent cell is stretched in the circumferential direction. Mechanical flexibility equal to an open-cell structure was obtained in a closed-cell structure by varying the geometric configuration of the stent cell. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. "Stent" auto-expansível nas dissecções da aorta tipo B Self-expanding stent in type B dissections of the aorta

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    1999-07-01

    Full Text Available O tratamento clínico das dissecções agudas da aorta do tipo B tem mortalidade em torno de 25% menor que a mortalidade cirúrgica. O tratamento cirúrgico das dissecções crônicas também produz uma morbidade e mortalidade elevadas. A utilização de "stents"auto-expansíveis endovasculares pode ser uma nova alternativa no tratamento destas lesões. De abril a dezembro de 1998 foram implantados 15 "stents" endovasculares, 10 em dissecções agudas e 5 em crônicas. A idade dos pacientes variou entre 48 e 75 anos (média=60,53±9,73 anos com 66,6% do sexo masculino. Os pacientes foram submetidos à esternotomia mediana, circulação extracorpórea (CEC com hipotermia profunda (18° - 20°C, parada circulatória total (PCT e perfusão cerebral retrógrada (PCR. A aorta transversa foi incisada e implantado o "stent" na aorta descendente sob auxílio de aortoscopia. Foram analisados os tempos de CEC, pinçamento aórtico, PCT, PCR, reaquecimento, ventilação mecânica, internação, sangramento trans e pós-operatório, reposição sangüínea, gasometria, curva de eventos e sobrevida. A mortalidade hospitalar (30 dias foi de 6,6%; 2 pacientes foram reoperados com 3 e 6 meses após a operação com dissecção da aorta ascendente e aneurisma roto distal ao "stent". Quatorze vêm sendo acompanhados com 1 a 8m de evolução, sendo que 85,7% estão livres de eventos e curva de sobrevida de 93,1%(240 dias. Concluímos que o implante de "stent"intraluminais auto-expansíveis apresentou mortalidade menor na fase aguda da doença (6,6% comparada à nossa experiência anterior com o tratamento clínico (30%. Apesar da amostra ser pequena, o procedimento parece ser promissor e necessita mais acompanhamento.The clinical treatment of acute type B aortic dissection has a mortality of about 25%, therefore, less than surgical mortality. The surgical treatment of chronic dissections also produces a high morbidity and mortality. The use of self

  1. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  2. Percutaneous reconstruction of the innominate bifurcation using the retrograde 'kissing stents' technique

    International Nuclear Information System (INIS)

    Nagata, Shun-ichi; Kazekawa, Kiyoshi; Matsubara, Shuko; Sugata, Sei

    2006-01-01

    Obstructions of the supraaortic vessels are an important cause of morbidity associated with a variety of symptoms. Percutaneous transluminal angioplasty has evolved as an effective and safe treatment modality for occlusive lesions of the supraaortic vessels. However, the endovascular management of an innominate bifurcation has not previously been reported. A 53-year-old female with a history of systematic hypertension, diabetes mellitus and hypercholesterolemia presented with left hemiparesis and dysarthria. Angiography of the innominate artery showed a stenosis of the innominate bifurcation. The lesion was successfully treated using the retrograde kissing stent technique via a brachial approach and an exposed direct carotid approach. The retrograde kissing stent technique for the treatment of a stenosis of the innominate bifurcation was found to be a safe and effective alternative to conventional surgery. (orig.)

  3. Disección de aorta: Aspectos básicos y manejo endovascular Aortic dissection: Basic aspects and endovascular management

    Directory of Open Access Journals (Sweden)

    Nicolás I Jaramillo

    2005-08-01

    Full Text Available El tratamiento de la patología aórtica torácica se complica por la asociación con una alta mortalidad en la reparación quirúrgica, y al mismo tiempo fragilidad y gran comorbilidad en los adultos de edad avanzada. En la búsqueda por reducir la incidencia de resultados negativos, en la década pasada se introdujo la técnica de intervención por la vía de la mínima invasión, con la colocación de dispositivos del tipo stent vía endovascular. La técnica, originalmente descrita por Parodi e inicialmente diseñada para uso en la corrección de aneurismas de aorta abdominal, ha sido adoptada para el uso en la patología aórtica torácica. El mejoramiento en el entendimiento de la fisiopatología y la historia natural de la enfermedad de la aorta torácica y el análisis de los resultados, han facilitado la toma de decisiones en cuanto al tratamiento en términos del tiempo de la intervención apropiada. El tratamiento de la disección de la aorta torácica con el uso de stent endovascular, es uno de los más recientes avances en el tratamiento y hoy recibe una atención especial, al punto que es una alternativa menos invasiva; incluso la tecnología está apenas en sus primeras etapas y en los últimos años se han mejorado significativamente el diseño y el sistema de liberación de estos dispositivos endovasculares conocidos como stent-grafts. Estas prótesis se utilizan de forma creciente en el tratamiento de aneurismas, disecciones, rupturas traumáticas, úlceras penetradas gigantes y hematomas intramurales de la aorta torácica descendente, con buenos resultados tanto tempranos como a mediano plazo. La poca frecuencia, la alta complejidad y la severidad de la patología, y al mismo tiempo el alto riesgo teórico de las complicaciones que se pueden generar, deben mantener cauto al operador, especialmente cuando esta técnica se aplica en pacientes jóvenes. De manera conceptual la solución por la vía endoluminal en las fases agudas

  4. Endovascular Treatment of Phlegmasia Cerulea Dolens with Impending Venous Gangrene: Manual Aspiration Thrombectomy as the First-Line Thrombus Removal Method

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Ozkan, Ugur; Demirturk, Orhan S.; Gur, Serkan

    2011-01-01

    Purpose: Our purpose was to report the outcome of endovascular treatment with manual aspiration thrombectomy as the first-line thromboablative method for phlegmasia cerulea dolens. Methods: Between October 2006 and May 2010, seven consecutive patients (5 women, 2 men; age range, 31–80 years) with the diagnosis of phlegmasia cerulea dolens secondary to acute iliofemoral deep venous thrombosis had endovascular treatment with manual aspiration thrombectomy. Catheter-directed thrombolysis and stent placement were used as adjunctive procedures. Phlegmasia was left-sided in five and right-sided in two patients. Results: All patients had associated great saphenous vein thrombosis in addition to iliofemoral deep vein thrombosis (DVT). Aspiration thrombectomy completely removed the thrombus from the popliteal vein to the inferior vena cava (IVC) in all cases. Three patients with May-Thurner syndrome had stent placement in the left common iliac vein. Two patients had early recurrences. Repeated aspiration thrombectomy was unsuccessful in one patient. There were no complications related to the procedure. One patient who had been successfully treated died of sepsis and another patient who had unsuccessful repeated interventions had below-the-knee amputation. Overall, the clinical success and survival rates of patients in this study were 86%. On follow-up, three patients with successful treatment were asymptomatic with no deep venous insufficiency. One of these patients died during the 4-month follow-up period. Two patients had mild ankle swelling with deep venous insufficiency. Conclusions: Manual aspiration thrombectomy with adjunctive use of catheter-directed thrombolysis and stent placement is an effective endovascular treatment method with high clinical success and survival rates for phlegmasia cerulean dolens.

  5. Endovascular treatment of ruptured true posterior communicating artery aneurysms.

    Science.gov (United States)

    Yang, Yonglin; Su, Wandong; Meng, Qinghai

    2015-01-01

    Although true posterior communicating artery (PCoA) aneurysms are rare, they are of vital importance. We reviewed 9 patients with this fatal disease, who were treated with endovascular embolization, and discussed the meaning of endovascular embolization for the treatment of true PCoA aneurysms. From September 2006 to May 2012, 9 patients with digital substraction angiography (DSA) confirmed true PCoA aneurysms were treated with endovascular embolization. Patients were followed-up with a minimal duration of 17 months and assessed by Glasgow Outcome Scale (GOS) score. All the patients presented with spontaneous subarachnoid hemorrhage from the ruptured aneurysms. The ratio of males to females was 1:2, and the average age of onset was 59.9 (ranging from 52 to 72) years. The preoperative Hunt-Hess grade scores were I to III. All patients had recovered satisfactorily. No permanent neurological deficits were left. Currently, endovascular embolization can be recommended as the top choice for the treatment of most true PCoA aneurysms, due to its advanced technique, especially the application of the stent-assisted coiling technique, combined with its advantage of mininal invasiveness and quick recovery. However, the choice of treatment methods should be based on the clinical and anatomical characteristics of the aneurysm and the skillfulness of the surgeon.

  6. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    Science.gov (United States)

    Zhang, Chang wei; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong

    2010-01-01

    Objective To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudoaneurysms presenting as intractable epistaxis. Materials and Methods For 14 consecutive patients with traumatic pseudoaneurysm presenting as refractory epistaxes, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudoaneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (ICA); out of which, two were managed with detachable balloons, two with covered stents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Results Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from ICA pseudoaneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. Conclusion In patients presenting with a history of craniocerebral trauma, traumatic pseudoaneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudoaneurysms. PMID:21076585

  7. Effects of electrocautery to provoke endovascular thermal injury Efeitos do eletrocautério para provocar lesão térmica endovascular

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Rossi

    2011-10-01

    Full Text Available PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.OBJETIVO: Investigar os efeitos de um modelo experimental de eletrocautério em provocar lesão venosa térmica endovascular. MÉTODOS: O eletrocautério endovascular foi colocado dentro de oito modelos experimentais de veia safena bovina. Cada uma foi dividida em oito segmentos e intensidades progressivas de energia elétrica liberada. Os efeitos macroscópicos e microscópicos foram analisados. RESULTADOS: Foram estudados quarenta segmentos de veia safena bovina. Quanto maior a energia elétrica aplicada pelo eletrocauterizador endovascular maiores foram as alteraçoes de picnose nuclear e mais intensa a retração citoplasmática observada. CONCLUSÃO: O eletrocautério endovascular experimental demonstrou ser capaz de induzir a destruição da camada íntima e provocar lesão térmica endovascular.

  8. Tratamento endovascular de lesões arteriais traumáticas Endovascular management of traumatic arterial injuries

    Directory of Open Access Journals (Sweden)

    Ruy Fernandes e Fernandes

    2011-03-01

    Full Text Available Introdução: As lesões arteriais traumáticas ocorrem em menos de 10% de politraumatizados e, nos países desenvolvidos, tem-se observado uma preponderância crescente de traumatismos vasculares iatrogénicos. Recentemente vários autores têm descrito a utilização de técnicas endovasculares com sucesso, pelo menor risco cirúrgico, em lesões de difícil acesso cujo tratamento convencional requer grande exposição cirúrgica, dificuldade técnica e mortalidade ou morbilidade apreciáveis. Os procedimentos endovasculares representam ainda uma alternativa terapêutica com menor mortalidade no tratamento de complicações crónicas de traumatismos vasculares, nomeadamente nos aneurismas pós-traumáticos do istmo aórtico (APTIA. Os autores apresentam uma série de doentes com lesões traumáticas arteriais diversas, em fase aguda ou crónica, tratados por via endovascular. Casos Clínicos: Sete doentes (21-77 anos, foram submetidos a tratamento endovascular de traumatismos vasculares na fase aguda ou crónica. Quatro doentes apresentavam lesões traumáticas agudas: 1 caso de rotura traumática do istmo aórtico (RTIA em politraumatismo por acidente de viação; 1 caso de rotura da artéria subclávia (RAS iatrogénica após tentativa de colocação de catéter de hemodiálise; 1 caso rotura de artéria renal (RAR durante angioplastia/stent por doença renovascular; 1 caso de fístula arterio-venosa (FAV da artéria renal intra-parenquimatosa iatrogénica após tumorectomia laparoscópica. Três doentes com complicações crónicas de traumatismos torácicos apresentavam falsos aneurismas do arco aórtico. Os doentes com roturas arteriais foram submetidos a exclusão endovascular com endoprótese e o doente com FAV renal foi submetido a embolização com coils. Os três doentes portadores de APTIA foram submetidos a: tratamento endovascular de aneurisma da aorta torácica (TEVAR-1; “debranching” com bypass carótido-subclávio e TEVAR-2

  9. Treatment of a spontaneous intracranial dissecting aneurysm with stent-assisted coil embolization

    International Nuclear Information System (INIS)

    Irie, Keiko; Negoro, Makoto; Hayakawa, Motoharu; Hayashi, Junichi; Kanno, Tetsuo

    2003-01-01

    Arterial dissection is now recognized as an important cause of stroke. Most reported dissections involve the extracranial portion of the internal carotid artery (ICA) and vertebral arteries. Spontaneous dissecting aneurysms of the intracranial ICA are uncommon. Endovascular treatment for cerebral aneurysms has become widespread; however, the dissecting aneurysm is still difficult to treat if the parent artery has to be preserved. More recently, stenting has been advocated for use with endosaccular coiling, with the coils held in place by the stent. We herein report a spontaneous intracranial ICA dissecting aneurysm in a 51-year-old woman who was treated using a new technique of combined stent and coils. (orig.)

  10. Endovascular brachytherapy to prevent restenosis after angioplasty; Endovaskulaere Brachytherapie in der Restenoseprophylaxe nach Angioplastie und Stentimplantation: Eine Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, W.A.; Bohndorf, K. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie

    2003-02-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [German] Die endovaskulaere Radiotherapie stellt das erste erfolgreiche Therapiekonzept in der Restenoseprophylaxe nach PTA und Stentimplantation dar. Am 3.11.2000 hat die amerikanische Food and Drug Administration erstmalig zwei Brachytherapiegeraete zur Restenoseprophylaxe nach Koronararterien-Stenting zugelassen. Grosse multizentrische, kontrollierte Studien wurden fuer das koronare Stromgebiet mit positiven Ergebnissen publiziert, die Datenlage im peripheren Stromgebiet ist noch ungenuegend. Beta-Strahler bieten Vorteile in der Anwendung, moeglicherweise auch in der Sicherheit, Gamma-Strahler dagegen sind besser klinisch evaluiert. Die primaere Indikation zur endovaskulaeren Brachytherapie

  11. Association between silent embolic cerebral infarction and continuous increase of P2Y12 reaction units after neurovascular stenting.

    Science.gov (United States)

    Kim, Bum Joon; Kwon, Joo Y; Jung, Jin-Man; Lee, Deok Hee; Kang, Dong-Wha; Kim, Jong S; Kwon, Sun U

    2014-10-01

    Endovascular procedures are one of the important treatment options for steno-occlusive arteries in ischemic stroke patients. However, embolic complications after such procedures are always a concern. The authors investigated the association between serial change of residual platelet reactivity and silent embolic cerebral infarction (SECI) after endovascular treatment. Ischemic stroke patients undergoing stenting of intra- or extracranial arteries were recruited prospectively. Residual platelet reactivity, represented by aspirin reaction units (ARUs) and P2Y12 reaction units (PRUs), was measured serially (6 hours before, immediately after, and 24 hours after the procedure). A loading dosage of aspirin (500 mg) and/or clopidogrel (300 mg) was given 24 hours before the procedure to patients naïve to antiplatelet agents, whereas the usual dosage (aspirin 100 mg and clopidogrel 75 mg) was continued for patients who had previously been taking these agents for more than a week. Diffusion-weighted MRI was performed before and 24 hours after the procedure to detect new SECIs. Clinical characteristics, baseline ARU and PRU values, and the change in ARU and PRU values after stenting were compared between patients with and without SECIs. Among 69 consecutive patients who underwent neurovascular stent insertion, 41 patients (59.4%) had poststenting SECIs. The lesion was located only at the vascular territory of the stented vessel in 21 patients (51.2%), outside the stented vessel territory in 8 patients (19.5%), and both inside and outside in 12 patients (29.3%). The occurrence of SECIs was not associated with the baseline ARU or PRU value, but was associated with PRU increase after stenting (36 ± 73 vs -12 ± 59, p = 0.007), deployment of a longer stent (31.1 ± 16.5 mm vs 21.8 ± 9.9 mm, p = 0.01), and stent insertion in extracranial arteries (78.1% vs 45.2%, p = 0.008). Stent length (OR 1.066, p = 0.01) and PRU change (OR 1.009, p = 0.04) were independently associated with

  12. Dissection of the V4 segment of the vertebral artery: clinicoradiologic manifestations and endovascular treatment

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Woong; Seo, Jeong Jin [Chonnam National University Medical School, Department of Radiology, Chonnam National University Hospital, 501-757Dong-gu, Gwangju (Korea); Kim, Tae Sun [Chonnam National University Medical School, Department of Neurosurgery, Chonnam National University Hospital, Dong-gu, Gwangju (Korea); Do, Huy M.; Jayaraman, Mahesh V.; Marks, Michael P. [Stanford University Medical Center, Department of Radiology, Stanford, California (United States)

    2007-04-15

    Intracranial vertebral artery (VA) dissection has three clinical presentations: ischemia, hemorrhage, and mass effect. Imaging findings of intracranial VA dissections vary according to clinical presentation. Irregular stenosis or occlusion of the VA is the most common finding in patients with posterior fossa infarction, whereas a dissecting aneurysm is the main feature in those with acute subarachnoid hemorrhage. A chronic, giant, dissecting aneurysm can cause mass effect on the brain stem or cranial nerves, as well as distal embolism. Magnetic resonance imaging is useful for detection of intramural hematomas and intimal flaps, both of which are diagnostic of VA dissection. Multidetector computed tomography angiography is increasingly used for diagnosis of VA dissection. Catheter angiography is still beneficial for evaluation of precise endoluminal morphology of the dissection before surgical or endovascular intervention. Endovascular treatment is now considered a major therapeutic option for patients with a ruptured dissecting aneurysm or a chronic dissecting aneurysm. Anticoagulation therapy is currently considered the initial treatment of choice in patients with posterior circulation ischemic symptoms. Endovascular treatment, such as stent-assisted angioplasty or coil occlusion at the dissection site, can be performed in selected patients with posterior fossa ischemic symptoms. (orig.)

  13. Dissection of the V4 segment of the vertebral artery: clinicoradiologic manifestations and endovascular treatment

    International Nuclear Information System (INIS)

    Yoon, Woong; Seo, Jeong Jin; Kim, Tae Sun; Do, Huy M.; Jayaraman, Mahesh V.; Marks, Michael P.

    2007-01-01

    Intracranial vertebral artery (VA) dissection has three clinical presentations: ischemia, hemorrhage, and mass effect. Imaging findings of intracranial VA dissections vary according to clinical presentation. Irregular stenosis or occlusion of the VA is the most common finding in patients with posterior fossa infarction, whereas a dissecting aneurysm is the main feature in those with acute subarachnoid hemorrhage. A chronic, giant, dissecting aneurysm can cause mass effect on the brain stem or cranial nerves, as well as distal embolism. Magnetic resonance imaging is useful for detection of intramural hematomas and intimal flaps, both of which are diagnostic of VA dissection. Multidetector computed tomography angiography is increasingly used for diagnosis of VA dissection. Catheter angiography is still beneficial for evaluation of precise endoluminal morphology of the dissection before surgical or endovascular intervention. Endovascular treatment is now considered a major therapeutic option for patients with a ruptured dissecting aneurysm or a chronic dissecting aneurysm. Anticoagulation therapy is currently considered the initial treatment of choice in patients with posterior circulation ischemic symptoms. Endovascular treatment, such as stent-assisted angioplasty or coil occlusion at the dissection site, can be performed in selected patients with posterior fossa ischemic symptoms. (orig.)

  14. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  15. Luminal flow amplifies stent-based drug deposition in arterial bifurcations.

    Directory of Open Access Journals (Sweden)

    Vijaya B Kolachalama

    2009-12-01

    Full Text Available Treatment of arterial bifurcation lesions using drug-eluting stents (DES is now common clinical practice and yet the mechanisms governing drug distribution in these complex morphologies are incompletely understood. It is still not evident how to efficiently determine the efficacy of local drug delivery and quantify zones of excessive drug that are harbingers of vascular toxicity and thrombosis, and areas of depletion that are associated with tissue overgrowth and luminal re-narrowing.We constructed two-phase computational models of stent-deployed arterial bifurcations simulating blood flow and drug transport to investigate the factors modulating drug distribution when the main-branch (MB was treated using a DES. Simulations predicted extensive flow-mediated drug delivery in bifurcated vascular beds where the drug distribution patterns are heterogeneous and sensitive to relative stent position and luminal flow. A single DES in the MB coupled with large retrograde luminal flow on the lateral wall of the side-branch (SB can provide drug deposition on the SB lumen-wall interface, except when the MB stent is downstream of the SB flow divider. In an even more dramatic fashion, the presence of the SB affects drug distribution in the stented MB. Here fluid mechanic effects play an even greater role than in the SB especially when the DES is across and downstream to the flow divider and in a manner dependent upon the Reynolds number.The flow effects on drug deposition and subsequent uptake from endovascular DES are amplified in bifurcation lesions. When only one branch is stented, a complex interplay occurs - drug deposition in the stented MB is altered by the flow divider imposed by the SB and in the SB by the presence of a DES in the MB. The use of DES in arterial bifurcations requires a complex calculus that balances vascular and stent geometry as well as luminal flow.

  16. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, Jacques; Chau, Yves; Mondot, Lydiane [CHU Nice, Unite de Neurointerventionnelle, Hopital St. Roch, Nice (France); Vargas, Julian; Szapiro, Jacek; Lonjon, Michel [CH Bastia, Service de Neurochirurgie, Bastia (France)

    2009-06-15

    Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique. A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year. Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement. Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year. (orig.)

  17. Efficacy of a Self-Expandable Porous Stent as the Sole Curative Treatment for Extracranial Carotid Pseudoaneurysms.

    Science.gov (United States)

    Chen, Peng Roc; Edwards, Nancy J; Sanzgiri, Aditya; Day, Arthur L

    2016-04-01

    Extracranial carotid pseudoaneurysms are uncommon vascular lesions. Even with conservative management complications can happen, such as delayed cerebral embolization or symptoms due to flow limitation. Although endovascular therapy can be curative, literature demonstrating a preferred technique is scant. Our goal was to evaluate the use of 1 technique only-the deployment of overlapping self-expandable porous stents-to treat a series of extracranial carotid pseudoaneurysms. From 2008 to 2014, 14 consecutive cases of symptomatic extracranial carotid pseudoaneurysms were managed with single or multilayer porous stents at our institution. Each patient underwent a standardized angiographic follow-up at 6 months. Twelve patients also received a follow-up computed tomography angiogram at 12 months, and yearly thereafter (median radiographic follow-up, 38 months). The total clinical follow-up period ranged between 6 and 69 months (median, 46 months). In our series, each of the extracranial carotid pseudoaneurysms appeared to be the result of carotid artery dissection with associated carotid stenosis at the origin of every pseudoaneurysm. Endovascular treatment consisted of 1-3 layers of self-expandable porous stents placed without balloon angioplasty. Immediately after stenting angiographic images were notable for stagnant opacification of the pseudoaneurysm through the stent(s). All pseudoaneurysms were completely obliterated by the 6-month follow-up angiogram and remained so throughout the radiographic follow-up period. Complications were minimal, consisting of 1 patient developing a mild Horner's syndrome after treatment that resolved during clinical follow-up. Extracranial carotid pseudoaneurysms can be successfully obliterated with the use of porous, self-expandable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. PTA and stenting for various types of Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Zhang Xinbao

    2011-01-01

    Objective: To investigate and evaluate PTA and stenting for various types of Budd-Chiari syndrome (BCS). Methods: 89 patients with BCS were diagnosed and treated during 7 years. The interventional procedures included: Percutaneous balloon dilatation (PBD) of inferior vena cava (IVC), PBD and stent placement for IVC, hepatic vein angioplasty via trans jugular vein, hepatic vein angioplasty via transhepatic and trans jugular approach, accessory hepatic vein angioplasty, percutaneous dual balloon dilatation for IVC and hepatic vein, and percutanous dual stent placement for IVC and hepatic vein. Results: The achievement ratio of PTA and stent placement was 96% and the mortality was 0%. The serious complication of PTA and stent placement of BCS was penetration into the pericardium, endovascular stent migration into right atrium. Conclusion: 1. PTA is a reliable procedures in treating type I a, II and III BCS, and TIPPS is useful for type I b BCS. But PTA and stenting is necessary for patients with type IV BCS. 2. Thrombolysis is needed for patients with type III, IV BCS. 3. Guiding of Color Doppler Ultrasound can improve the success of percutanous hepatic vein and reduce complications. (authors)

  19. Lean manufacturing and Toyota Production System terminology applied to the procurement of vascular stents in interventional radiology.

    Science.gov (United States)

    de Bucourt, Maximilian; Busse, Reinhard; Güttler, Felix; Wintzer, Christian; Collettini, Federico; Kloeters, Christian; Hamm, Bernd; Teichgräber, Ulf K

    2011-08-01

    OBJECTIVES: To apply the economic terminology of lean manufacturing and the Toyota Production System to the procurement of vascular stents in interventional radiology. METHODS: The economic- and process-driven terminology of lean manufacturing and the Toyota Production System is first presented, including information and product flow as well as value stream mapping (VSM), and then applied to an interdisciplinary setting of physicians, nurses and technicians from different medical departments to identify wastes in the process of endovascular stent procurement in interventional radiology. RESULTS: Using the so-called seven wastes approach of the Toyota Production System (waste of overproducing, waiting, transport, processing, inventory, motion and waste of defects and spoilage) as well as further waste characteristics (gross waste, process and method waste, and micro waste), wastes in the process of endovascular stent procurement in interventional radiology were identified and eliminated to create an overall smoother process from the procurement as well as from the medical perspective. CONCLUSION: Economic terminology of lean manufacturing and the Toyota Production System, especially VSM, can be used to visualise and better understand processes in the procurement of vascular stents in interventional radiology from an economic point of view.

  20. Stent-induced flow disturbances in the ipsilateral external carotid artery following internal carotid artery stenting: a temporary cause of jaw claudication.

    Science.gov (United States)

    Giurgea, Georgiana-Aura; Haumer, Markus; Mlekusch, Irene; Sabeti-Sandor, Schila; Dick, Petra; Schillinger, Martin; Minar, Erich; Mlekusch, Wolfgang

    2017-07-01

    We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.

  1. Identification of critical areas of carotid stent navigation by measurement of resistive forces in vitro, using silicone phantoms

    International Nuclear Information System (INIS)

    Sengupta, A.; Kesavadas, T.; Baier, R.E.; Hoffmann, K.R.; Schafer, S.

    2007-01-01

    Manipulation of surgical tools in neuro-endovascular surgery presents problems that are unique to this procedure. Navigating tools through arterial complexities without appropriate visual or force feedback information often causes tool snagging, plaque dislocations and formation of thrombosis from the damage of the arterial wall by the tools. Identifying the critical areas in the vasculature during navigation of endovascular tools, will not only ensure safer surgical planning but also reduce risks of vessel damage. In the present research, resistive forces of stent navigation were measured in-vitro using silicone phantoms and clinically relevant surgical devices. The patterns of variation of the forces along the path of the stent movement were analyzed and mapped along the path of stent movement using a color code. It was observed that the forces changed along the length of the vessel, independent of the insertion length but based on the curvature of the vessel and the contact area of the device in the vessel lumen. (orig.)

  2. Emergency Endovascular “Bridge” Treatment for Iliac-Enteric Fistula

    International Nuclear Information System (INIS)

    Franchin, Marco; Tozzi, Matteo; Piffaretti, Gabriele; Carrafiello, Gianpaolo; Castelli, Patrizio

    2011-01-01

    Aortic aneurysm has been reported to be the dominant cause of primary iliac-enteric fistula (IEF) in >70% of cases [1]; other less common causes of primary IEF include peptic ulcer, primary aortitis, pancreatic pseudocyst, or neoplastic erosion into an adjacent artery [2, 3]. We describe an unusual case of IEF managed with a staged approach using an endovascular stent-graft as a “bridge” in the emergency setting to optimize the next elective definitive excision of the lesion.

  3. Advances in endovascular aneurysm treatment: are we making a difference?

    International Nuclear Information System (INIS)

    Katz, Jeffrey M.; Ougorets, Igor; Tsiouris, Apostolos J.; Biondi, Alessandra; Salvaggio, Kimberly A.; Gobin, Y. Pierre; Stieg, Philip E.; Riina, Howard A.

    2005-01-01

    Recent advancements in endovascular aneurysm repair, including bioactive and expansile coils and intracranial stents, hold promise for improved aneurysm occlusion rates. We report the immediate and midterm clinical and angiographic outcomes of a consecutive series of patients treated since the advent of these technologies. Clinical and radiological records of 134 patients with 142 aneurysms treated between 2001 and 2004 were retrospectively evaluated by an independent neurologist. Endovascular procedures were analyzed by an independent neuroradiologist blinded to all clinical information. Seventy-two ruptured and 60 un-ruptured saccular aneurysms, nine fusiform and one post-traumatic aneurysm were treated. Matrix coils were used in 53% of saccular aneurysms and HydroCoils in 13% of all aneurysms. Neuroform stents were deployed in 19% of aneurysms. Angiographic total or subtotal occlusion was achieved in 76% of cases and in 96% at last follow-up. Aneurysm recanalization was observed in 14% over a mean follow-up of 12 months, and 18% of aneurysms were retreated. Clinically relevant complications occurred in 6.0%, resulting in procedure-related morbidity of 0.6% and 0.6% mortality at 6 months. No aneurysm bled over a cumulative 1,347 months of observation. Newer embolization technologies can be exploited successfully even in more complex aneurysms with very low morbidity and mortality. (orig.)

  4. Availability of endovascular therapies for cerebrovascular disease at primary stroke centers.

    Science.gov (United States)

    Alberts, Mark J; Range, Jean; Spencer, William; Cantwell, Vicki; Hampel, M J

    2017-02-01

    Background Endovascular therapies (EVTs) are useful for treating cerebrovascular disease. There are few data about the availability of such services at primary stroke centers (PSCs). Our hypothesis was that some of these services may be available at some PSCs. Methods We conducted an internet-based survey of hospitals certified as PSCs by the Joint Commission. The survey inquired about EVTs such as intra-arterial (IA) lytics, IA mechanical clot removal, coiling of aneurysms, and cervical arterial stenting, physician training, coverage models, hospital type, and outcomes. Chi-square analyses were used to detect differences between academic and community PSCs. Results Data were available from 352 PSCs, of which 75% were community hospitals, 23% academic medical centers, and 80% were non-profit; almost half (48%) see 300 or more patients annually with ischemic stroke. A majority (60%) provided some or all EVTs on site, while 29% had none on site and no plans to add them. Among the respondents offering EVTs, 95% offered stenting of neck vessels, 86% IA lytics, 80% IA mechanical, and 74% aneurysm coiling. The majority (>55%) that did offer such services provided them 24/7/365. Most endovascular coverage was provided by interventional neuroradiologists (60%), fellowship trained endovascular neurosurgeons (42%), and interventional radiologists (41%). The majority of hospitals (81%) did not participate in an audited national registry. Conclusions A variety of EVT services are offered at many PSCs by interventionalists with diverse types of training. The availability of such services is clinically relevant now with the proven efficacy of mechanical thrombectomy for ischemic stroke.

  5. Stent-Assisted Coil Embolization of a Mycotic Renal Artery Aneurysm by Use of a Self-Expanding Neurointerventional Stent

    International Nuclear Information System (INIS)

    Rabellino, Martin; García-Nielsen, Luis; Zander, Tobias; Baldi, Sebastián; Llorens, Rafael; Maynar, Manuel

    2011-01-01

    Mycotic aneurysms are uncommon, especially those located in visceral arteries. We present a case of a patient with two visceral mycotic aneurysms due to bacterial endocarditis, one located in right upper pole renal artery and the second in the splenic artery. Both aneurysms were treated as endovascular embolization using microcoils. In the aneurysm located at the renal artery, the technique of stent-assisted coils embolization was preferred to avoid coils migration due to its wide neck. The stent used was the Solitaire AB, which was designed for the treatment of intracranial aneurysms and was used recently in acute stroke as a mechanical thrombectomy device. Complete embolization of the aneurysm was achieved, preserving all the arterial branches without nephrogram defects in the final angiogram.

  6. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  7. Laser Atherectomy for Treatment of Femoropopliteal In-Stent Restenosis.

    Science.gov (United States)

    Armstrong, Ehrin J; Thiruvoipati, Thejasvi; Tanganyika, Kundai; Singh, Gagan D; Laird, John R

    2015-08-01

    To investigate if laser atherectomy with adjunctive balloon angioplasty can improve endovascular treatment outcomes for femoropopliteal in-stent restenosis (ISR). A dual center study included 135 symptomatic patients (mean age 71 years; 76 men) who underwent endovascular treatment of femoropopliteal ISR between 2006 and 2013. Of these, 54 (40%) were treated with laser atherectomy and the remaining 81 patients with balloon angioplasty alone. Angiographic images were reviewed for lesion morphology and characteristics, TransAtlantic InterSociety Consensus (TASC) II classification, and distal runoff. Class I ISR was defined as focal lesions ≤50 mm, class II ISR as lesions >50 mm, and class III ISR as stent total occlusion. Recurrent ISR was determined by a peak systolic velocity ratio >2.4 by duplex ultrasound. Patients treated with laser atherectomy had longer mean ISR lesion length (222 vs 114 mm, patherectomy and rates of recurrent restenosis or occlusion for patients with class I/II ISR, but there was a significantly lower rate of target lesion revascularization at 2 years among patients treated with laser atherectomy (14% vs 44%, p=0.05). In comparison, patients with class III ISR treated with laser atherectomy had lower rates of recurrent restenosis at 1 year (54% vs 91%, p=0.05) and 2 years (69% vs 100%, p=0.05). Patients with class III ISR treated with laser atherectomy also had lower rates of recurrent in-stent occlusion at 2-year follow-up (33% vs 71%, p=0.04). When used to treat complex ISR, including in-stent occlusions, laser atherectomy with adjunctive balloon angioplasty may be associated with improved patency. © The Author(s) 2015.

  8. Endovascular Treatment of Chronic Mesenteric Ischemia: Report of Five Cases

    International Nuclear Information System (INIS)

    Nyman, Ulf; Ivancev, Krasnodar; Lindh, Mats; Uher, Petr

    1998-01-01

    Purpose: To evaluate the midterm results of percutaneous transluminal angioplasty (PTA) and stent placement in stenotic and occluded mesenteric arteries in five consecutive patients with chronic mesenteric ischemia. Methods: Five patients with 70%-100% obliterations of all mesenteric vessels resulting in chronic mesenteric ischemia (n= 4) and as a prophylactic measure prior to abdominal aortic aneurysm repair (n= 1) underwent PTA of celiac and/or superior mesenteric artery (SMA) stenoses (n= 2), primary stenting of ostial celiac occlusions (n= 2), and secondary stenting of a SMA occlusion (n= 1; recoil after initial PTA). All patients underwent duplex ultrasonography (US) (n= 3) and/or angiography (n= 5) during a median follow-up of 21 months (range 8-42 months). Results: Clinical success was obtained in all five patients. Asymptomatic significant late restenoses (n3) were successfully treated with repeat PTA (n= 2) and stenting of an SMA occlusion (n= 1; celiac stent restenosis). Recurrent pain in one patient was interpreted as secondary to postsurgical abdominal adhesions. Two puncture-site complications occurred requiring local surgical treatment. Conclusions: Endovascular techniques may be attempted prior to surgery in cases of stenotic or short occlusive lesions in patients with chronic mesenteric ischemia. Surgery may still be preferred in patients with long occlusions and a low operative risk

  9. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  10. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  11. Percutaneous reconstruction of the innominate bifurcation using the retrograde 'kissing stents' technique

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shun-ichi; Kazekawa, Kiyoshi; Matsubara, Shuko [Fukuoka University Chikushi Hospital, Department of Neurosurgery, Chikushino, Fukuoka (Japan); Sugata, Sei [Bironoki Neurosurgical Hospital, Shibushi, Kagoshima (Japan)

    2006-08-15

    Obstructions of the supraaortic vessels are an important cause of morbidity associated with a variety of symptoms. Percutaneous transluminal angioplasty has evolved as an effective and safe treatment modality for occlusive lesions of the supraaortic vessels. However, the endovascular management of an innominate bifurcation has not previously been reported. A 53-year-old female with a history of systematic hypertension, diabetes mellitus and hypercholesterolemia presented with left hemiparesis and dysarthria. Angiography of the innominate artery showed a stenosis of the innominate bifurcation. The lesion was successfully treated using the retrograde kissing stent technique via a brachial approach and an exposed direct carotid approach. The retrograde kissing stent technique for the treatment of a stenosis of the innominate bifurcation was found to be a safe and effective alternative to conventional surgery. (orig.)

  12. Endovascular Treatment of Totally Occluded Superior Mesenteric Artery by Retrograde Crossing via the Villemin Arcade

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Seitun, Sara; Bovio, Giulio; Fornaro, Rosario

    2013-01-01

    Chronic mesenteric ischemia (CMI) is a rare disorder that is commonly caused by progressive atherosclerotic stenosis or occlusion of one or more mesenteric arteries. Endovascular treatment for symptomatic CMI represents a viable option, especially in high-operative risk patients. We report a case of acute symptomatic CMI with chronic totally occlusion of the superior mesenteric artery (SMA) associated with significant stenosis of celiac trunk (CT) and inferior mesenteric artery (IMA) that underwent endovascular treatment of all the three mesenteric arteries: stenting of CT and IMA stenosis, and recanalization of the SMA occlusion by retrograde crossing via the Villemin arcade.

  13. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses

    International Nuclear Information System (INIS)

    Gizewski, E.R.; Weber, R.; Forsting, M.

    2011-01-01

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS (≥ 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  14. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  15. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  16. Duplex criteria for determination of in-stent stenosis after angioplasty and stenting of the superficial femoral artery.

    Science.gov (United States)

    Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K

    2009-01-01

    Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis or=50% in-stent stenosis, a PSV >or=190 had 88% sensitivity, 95% specificity, a 98% positive predictive value (PPV), and a 72% negative predictive value (NPV); for Vr, a ratio of >1.50 had 93% sensitivity, 89% specificity, a 96% PPV, and a 81% NPV. To detect >or=80% in-stent stenosis, a PSV >or=275 had 97% sensitivity, 68% specificity, a 67% PPV, and a 97% NPV; a Vr ratio >or=3.50 had 74% sensitivity, 94% specificity, a 77% PPV, and a 88% NPV. Combining a PSV >or=275 and a Vr >or=3.50 to determine >or=80% in-stent stenosis had 74% sensitivity, 94% specificity, a 88% PPV, and a 85% NPV; odds ratio was 42.17 (95% confidence interval, 10.20-174.36, P or=80% in-stent stenosis. A significant drop in ABI (>0.15) correlated with a >62% in-stent stenosis, although the adjusted correlation coefficients was low (R(2) = 0.31, P = .02). PSV and Vr appear to have a significant role in predicting in-stent stenosis. To determine >or=80% stenosis, combining PSV >or=275 cm/s and Vr >or=3.50 is highly specific and predictive.

  17. Immediate endovascular stent-graft repair of an acute traumatic

    African Journals Online (AJOL)

    Enrique

    device intended for abdominal deployment. The stent-graft was manually removed from its short delivery device and ... Largely on the basis of the Parmley report, standard teaching was that these injuries ... 5 mm to allow adequate proximal anchorage. Tactics to ... Temporary hypotension is generally induced during the.

  18. Renal artery stent fracture with refractory hypertension: a case report and review of the literature.

    Science.gov (United States)

    Chua, Su-Kiat; Hung, Huei-Fong

    2009-07-01

    A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.

  19. Correção endovascular de aneurisma da artéria esplénica: caso clínico Endovascular correction of splenic artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    José Almeida Lopes

    2012-06-01

    Full Text Available Os aneurismas da artéria esplénica, embora sejam os aneurismas esplâncnicos mais frequentes, cursam com uma prevalência de apenas 0,01%. Neste contexto os autores apresentam um caso clínico de uma doente de 41 anos com aneurisma da artéria esplénica de 20x29mm, tratada através da colocação de um stent coberto auto-expansível (Gore®, Viabahn®. É realizada uma revisão da literatura, das possíveis complicações e feita referência às várias hipóteses de tratamento, dando particular ênfase às novas técnicas endovasculares.Splenic artery aneurysms, although they are the most common splanchnic aneurysms, they have a prevalence of only 0,01%. In this context the authors present a case report of a 41 years female patient with a splenic artery aneurysm of 20x29mm, treated by deployment of a covered self-expandable stent (Gore® Viabahn®. It is performed a literature review of the pathology in question, possible complications and made reference to the various treatment options, with particular emphasis on the new endovascular techniques.

  20. Enterprise stent for waffle-cone stent-assisted coil embolization of large wide-necked arterial bifurcation aneurysms.

    Science.gov (United States)

    Padalino, David J; Singla, Amit; Jacobsen, Walter; Deshaies, Eric M

    2013-01-01

    Large wide-necked arterial bifurcation aneurysms present a unique challenge for endovascular coil embolization treatment. One technique described in the literature deploys a Neuroform stent into the neck of the aneurysm in the shape of a waffle-cone, thereby acting as a scaffold for the coil mass. This case series presents four patients with large wide-necked bifurcation aneurysms treated with the closed-cell Enterprise stent using the waffle-cone technique. Four patients (59 ± 18 years of age) with large wide-necked arterial bifurcation aneurysms (three basilar apex and one MCA bifurcation) were treated with the waffle-cone technique using the Enterprise stent as a supporting device for stent-assisted coil embolization. Three of the patients presented with aneurysmal subarachnoid hemorrhage (Hunt-Hess 2-3; Fisher Grade 3-4). There was no procedural morbidity or mortality associated with treatment itself. One aneurysm was completely obliterated, and three had small residual necks. One patient developed an area of PCA infarct and visual field cut one month after the procedure and required recoiling of the residual neck. The flared ends of the Enterprise stent remodeled the aneurysm neck by conforming to the shape of the neck without any technical difficulty, resulting in a stable scaffold holding the coils into the aneurysm. The closed cell construction, flexibility, and flared ends of the Enterprise stent allow it to conform to the waffle-cone configuration and provide a stable scaffold for coil embolization of large wide-necked arterial bifurcation aneurysms. We have had excellent initial results using the Enterprise stent with the waffle-cone technique. However, this technique is higher risk than standard treatment methods and therefore should be reserved for large wide-necked bifurcation aneurysms where Y stenting is needed, but not possible, and surgical clip ligation is not an option.

  1. Endovascular Treatment of Central Vein Stenoses and/or Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Maskova, Jana; Komarkova, Jana; Kivanek, Jiri; Danes, Jan; Slavikova, Marcela

    2003-01-01

    Purpose: To report our experience and results with the endovascular treatment of central vein stenoses and occlusions in hemodialysis patients. Methods: Between October 1999 and August 2001 (22 months) we performed 22 interventional procedures in 14 hemodialysis patients (8 women, 6 men) ranging in age from 38 to 87 years (mean 76 years). The indication for intervention was stenosis (n = 10) or occlusion (n =4) of a central vein in the upper arm used for dialysis inpatients with arm swelling and/or shunt malfunction. All patients had a previous history of subclavian vein cannulation. There were six percutaneous transluminal angioplasties (PTAs) and eight primary stentplacements and eight repeat interventions. Seven were for restenoses and one for early occlusion, with two secondary stent placements and six PTA of in-stent stenoses. In two patients a second stent was implanted. The mean follow-up was 8.5 months (range 1-19 months). All stents were self-expandable with diameters ranging from 9 to 16 mm. Results: All but one of the procedures was technically successful (95%, n = 21). The patient with an unsuccessful procedure died 1 month after the procedure, but the death was not procedure-related. During follow-up three patients died with a patent shunt and central vein, none of them in connection with the procedure. No complication occurred during the interventional procedures. One patient was lost to follow-up. The primary patency rate at 12 months was 43%, with a primary assisted patency rate of 83% and a secondary patency rate of 100% (n 6). Conclusion: Central vein stenoses and occlusions are associated with previous subclavian vein cannulation. They are a serious problem in hemodialysis patients with a shunt on the same arm.Endovascular treatment is a suitable option for these patients

  2. Excellent long-term results with iliac stenting in local anesthesia for post-thrombotic syndrome

    DEFF Research Database (Denmark)

    Klitfod, Lotte; Just, Sven; Foegh, Pia

    2015-01-01

    BACKGROUND: Only 20% of iliac veins will recanalize on anticoagulation (AC) treatment alone and may, therefore, develop venous obstruction after iliofemoral deep venous thrombosis (DVT). A considerable number of these patients will suffer from post-thrombotic syndrome (PTS) leading to impaired qu...... stent was 89% (17/19) and 16 patients (84 %) had almost or total symptom relief at follow-up. CONCLUSION: Endovascular stenting of iliac obstruction in local anesthesia is minimally invasive and shows excellent long-term outcomes for patients suffering from PTS....

  3. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    International Nuclear Information System (INIS)

    Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan

    2005-01-01

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series

  4. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    International Nuclear Information System (INIS)

    Silverberg, Daniel; Yalon, Tal; Halak, Moshe

    2015-01-01

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft

  5. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  6. Endovascular treatment of intracranial aneurysms using liquid polymer injection

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Xu Yi; Hong Bo

    2004-01-01

    Objective: To report our preliminary clinical experience in embolization of intracranial aneurysms with liquid polymer (Onyx). Methods: One case of posterior communicating artery aneurysm was treated with Onyx and microcoils, while the other one with multiple basilar aneurysms was treated by Onyx combined with stent-coiling technique. Results: All the aneurysms were totally occluded with patency of parent arteries. There was no procedure-related complication. The patients recovered well during clinical follow-up for 3 months. The angiographic follow-up in one patient showed the result was stable and Onyx was totally apart from the flow in parent artery. Conclusions: Short-term result suggests that endovascular treatment of intracranial aneurysms with liquid polymer is safe and effective, however more experience is needed. (authors)

  7. [Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses].

    Science.gov (United States)

    Gizewski, E R; Weber, R; Forsting, M

    2011-02-01

    Approximately 6 - 50% of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12%, and up to 19% in the case of high-grade IAS (≥ 70%). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7% at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40% depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Dynamic Geometric Analysis of the Renal Arteries and Aorta following Complex Endovascular Aneurysm Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Kim, John J; Lee, Jason T; Dalman, Ronald L; Cheng, Christopher P

    2017-08-01

    Aneurysm regression and target vessel patency during early and mid-term follow-up may be related to the effect of stent-graft configuration on the anatomy. We quantified geometry and remodeling of the renal arteries and aneurysm following fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). Twenty-nine patients (mean age, 76.8 ± 7.8 years) treated with F- or Sn-EVAR underwent computed tomography angiography at preop, postop, and follow-up. Three-dimensional geometric models of the aorta and renal arteries were constructed. Renal branch angle was defined relative to the plane orthogonal to the aorta. End-stent angle was defined as the angulation between the stent and native distal artery. Aortic volumes were computed for the whole aorta, lumen, and their difference (excluded lumen). Renal patency, reintervention, early mortality, postoperative renal impairment, and endoleak were reviewed. From preop to postop, F-renal branches angled upward, Sn-renal branches angled downward (P renals exhibited increased end-stent angulation (12 ± 15°, P renals, whereas F-renals exhibited increased end-stent angulation (5 ± 10°, P renal stent patency was 94.1% and renal impairment occurred in 2 patients (6.7%). Although F- and Sn-EVAR resulted in significant, and opposite, changes to renal branch angle, only Sn-EVAR resulted in significant end-stent angulation increase. Longitudinal geometric analysis suggests that these anatomic alterations are primarily generated early as a consequence of the procedure itself and, although persistent, they show no evidence of continued significant change during the subsequent postoperative follow-up period. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. One-stage surgery in combination with thoracic endovascular grafting and resection of T4 lung cancer invading the thoracic aorta and spine

    OpenAIRE

    Sato, Seijiro; Goto, Tatsuya; Koike, Terumoto; Okamoto, Takeshi; Shoji, Hirokazu; Ohashi, Masayuki; Watanabe, Kei; Tsuchida, Masanori

    2017-01-01

    A novel strategy of one-stage surgery in combination with thoracic endovascular grafting and resection for T4 lung cancer invading the thoracic aorta and spine is described. A 56-year-old man with locally advanced lung cancer infiltrating the aortic wall and spine underwent neoadjuvant chemotherapy and thoracic irradiation, followed by en bloc resection of the aortic wall and spine with thoracic endovascular grafting. He developed postoperative chylothorax, but there were no stent graft-relat...

  10. Effects of 32P radioactive stents on in-stent restenosis in a double stent injury model of the porcine coronary arteries

    International Nuclear Information System (INIS)

    Kim, Han-Soo; Chan, Rosanna C.; Kollum, Marc; Au, Arthur; Tio, Fermin O.; Yazdi, Hamid A.; Ajani, Andrew E.; Waksman, Ron

    2001-01-01

    Background: The major limitation of coronary stenting remains in-stent restenosis, due to the development of neointimal proliferation. Radioactive stents have demonstrated the ability to reduce this proliferation in the healthy nonatherosclerotic porcine animal model. However, inhibition of tissue proliferation in the in-stent restenotic lesion in a porcine model is not well characterized. The objective of this study was to examine the efficacy and safety of the 32 P radioactive stent for the treatment of in-stent restenosis in a double stent injury model of the porcine coronaries. Methods and Materials: Eighteen coronary arteries in 9 pigs underwent nonradioactive stent (8 mm in length) implantation. Thirty days after the initial stent implantation, a 32 P radioactive stent (18 mm in length) with an activity of 0 and 18 μCi was implanted to cover the initial stent. The swine were killed 30 days after the second stent implantation. Histomorphometric analysis was performed for vessel area (VA), stent strut area (SSA), intimal area (IA), and lumen area (LA). Results: Injury scores, VA, SSA, and LA were similar among the control and radiated groups. Neointimal formation was significantly reduced after placement of radioactive stents as compared to control in both the overlapped (0.93±0.12 vs. 1.31±0.51 mm 2 , p 2 , p 32 P radioactive stents may be safe and effective in reducing neointimal formation leading to in-stent restenosis. Longer follow-up will be required to examine whether these positive findings can be maintained

  11. Endovascular management of a carotid aneurysm into the sphenoid sinus presenting with epistaxis.

    Science.gov (United States)

    Akkari, Mohamed; Gascou, Grégory; Trévillot, Vincent; Bonafé, Alain; Crampette, Louis; Machi, Paolo

    2015-12-01

    Non-traumatic cavernous internal carotid artery (ICA) aneurysms are rare, and favour the occurrence of massive recurrent epistaxis, which is associated with a high mortality rate. We report the case of a 67-year-old woman presenting a ruptured ICA aneurysm extending into the sphenoid sinus, revealed by epistaxis. Selective coil embolization of the aneurysm was performed. Flow-diverter stents were deployed in order to utterly exclude the aneurysm and prevent revascularization. Anti-platelet treatment was provided to lower the risk of in-stent thrombosis. A left frontal hematoma associated with a subarachnoid haemorrhage occurred at day 2. Outcome was favourable with no neurological sequelae, and no clinical recurrence of epistaxis occurred. A 4 months follow-up digital subtraction angiography showed a complete exclusion of the aneurysm. In addition, a magnetic resonance cerebral angiography at 16 months showed stable results. Thus, this two-stage endovascular procedure has proven its effectiveness in preventing epistaxis recurrence while preserving the ICA patency. © The Author(s) 2015.

  12. Aortic Stent-Graft Infection Following Septic Complications of a Kidney Stone

    International Nuclear Information System (INIS)

    Berg, H. Rogier van den; Leijdekkers, Vanessa J.; Vahl, Anco

    2006-01-01

    A 73-year-old man was treated because of a renal pelvis blowout of the left kidney for which he received a nephrostomy catheter without antibiotic prophylaxis. Almost a year previously this patient had undergone endovascular repair of a symptomatic infrarenal abdominal aorta aneurysm. Four weeks after the diagnosis and treatment of the ruptured renal pelvis, a new computed tomography scan and ultrasound-guided fine needle aspiration confirmed the diagnosis of infected aortic stent-graft. An extra-anatomic axillo-uniiliac bypass and graft excision was performed. Two weeks after discharge the patient returned to the hospital with an occlusion of his left renal artery and died of renal failure. This is the first time an infected aortic stent-graft after a renal pelvis blowout has been reported. Although infections of aortic stent-grafts occur rarely, one should be aware of the possibility in aortic stent-graft patients undergoing abdominal procedures without antibiotic prophylaxis

  13. Unstable patients with retroperitoneal vascular trauma: an endovascular approach.

    Science.gov (United States)

    Boufi, Mourad; Bordon, Sébastien; Dona, Bianca; Hartung, Olivier; Sarran, Anthony; Nadeau, Sébastien; Maurin, Charlotte; Alimi, Yves S

    2011-04-01

    In hemodynamically unstable patients, the management of retroperitoneal vascular trauma is both difficult and challenging. Endovascular techniques have become an alternative to surgery in several trauma centers. Between 2004 and 2006, 16 patients (nine men, mean age: 46 years, range: 19-79 years) with retroperitoneal vascular trauma and hemodynamic instability were treated using an endovascular approach. The mean injury severity score was 30.7 ± 13.1. Mean systolic blood pressure and the shock index were 74 mm Hg and 1.9, respectively. Vasopressor drugs were required in 68.7% of cases (n = 11). Injuries were attributable to road traffic accidents (n = 15) and falls (n = 1). The hemorrhage sites included the internal iliac artery or its branches (n = 12) with bilateral injury in one case, renal artery (n = 2), abdominal aorta (n = 1), and lumbar artery (n = 1). In all, 14 coil embolizations and three stent-grafts were implanted. The technical success rate was 75%, as early re-embolization was necessary in one case and three patients died during the perioperative period. Six patients died during the period of hospitalization (37.5%). No surgical conversion or major morbidity was reported. In comparison with particulates, coil ± stent-graft may provide similar efficacy with regard to survival, and thus may be a valuable solution when particulate embolization is not available or feasible. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  14. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  15. Endovascular abdominal aortic repair for AAA. Anatomical suitability and limitation in Japanese population according to the inclusion criteria of Zenith AAA stent graft

    International Nuclear Information System (INIS)

    Kitagawa, Atsushi; Okita, Yutaka; Okada, Kenji

    2009-01-01

    Since 2007, the EVAR (endovascular abdominal aortic repair) grafts, Zenith, Excluder and Powerlink had been commercially available in Japan. However, a small iliac artery, typical of Japanese population especially in women, was a limiting factor to indicate EVAR. We analyzed the suitability of EVAR in Japanese population according to the inclusion criteria of Zenith AAA stent graft in the current study. From January 2006 to December 2007, 106 AAA (abdominal aortic aneurysm) patients (88 men, 18 women) with a mean age of 73 years were investigated in our institution by multi-slice CT scan in terms of suitability of EVAR, then we measured their abdominal aorta and iliac artery parameters as follows; proximal neck diameter (PND) and length (PNL), common iliac artery diameter (CIAD) and length (CIAL), suprarenal (SNA) and infrarenal neck angulation (INA), external iliac artery diameter (EIAD) and aortic length from the lowest renal artery to the aortic bifurcation (AOL). The inclusion criteria for Zenith AAA stent graft treatment were; PND: 18-28 mm, PNL more than 15 mm, unilateral CIAD less than 20 mm, CIAL at least 10 mm, SNA less than 45 degree and INA less than 60 degree, unilateral EIAD more than 7.5 mm. The indication of EVAR was 25.5% (27/106 patients), and was especially very low in women (5.6%) strictly according to the inclusion criteria of the Zenith AAA stent graft. The main reason of exclusion of EVAR was proximal short neck (40.5%), small iliac artery (30.4%) and infrarenal aortic neck angulation (29.1%). In our analysis, female AAA patients had small PNL and EIAD with angulated neck compared with male AAA ones. Anatomical suitability of EVAR in Japanese population strictly following by the inclusion criteria of Zenith AAA stent graft was low due to their characteristic differences from the European Union (EU) and the United States (US) patients, such as short proximal neck, steep neck angulation and small iliac artery, especially in women. More flexible

  16. Endovascular treatment of radiation-induced carotid blowout syndrome. Report of two cases

    International Nuclear Information System (INIS)

    Adachi, Akihiko; Kobayashi, Eiichi; Watanabe, Yoshiyuki; Yoneyama, Tomoko S.; Hayasaka, Michihiro; Suzuki, Homare; Okamoto, Yoshitaka; Saeki, Naokatsu

    2011-01-01

    Carotid Blowout Syndrome (CBS), or Carotid Artery Rupture (CAR), is a delayed complication with potentially fatal consequences occurring after the implementation of radiotherapy on head and neck tumors. In this report we describe two patients received endovascular treatment for severe hemorrhagic CBS developing 36 and 2 years, respectively, after radiotherapy. Both patients survived and responded positively to treatment. Case 1 was an 80-year-old woman found with minor hemorrhage near the bifurcation of the common carotid artery, 36 years after neck irradiation. She experienced frequent hemorrhagic events during the following years. Six years after the initial discovery of bleeding, she experienced massive hemorrhage, lapsed into shock, and was admitted to an Emergency Room. Connective tissue around the carotid artery was largely exposed due to neck skin defect. After hemorrhage was halted by manual compression, transient hemostasis was achieved with coil embolization of the aneurysm presumed to be the source of bleeding. Recurrent hemorrhage developed two weeks later with unraveled coil mass extrusion. Parent artery occlusion was performed by endovascular trapping, achieving permanent hemostasis. Case 2 presented massive nasal bleeding originating from the petrous segment of the internal carotid artery, 2 years after having been treated with heavy particle irradiation for olfactory neuroblastoma. Ischemic tolerance was confirmed by balloon occlusion test. Based on previous experiences, the bleeding was immediately halted by endovascular trapping. Both patients were subsequently discharged, free of new neurological symptoms. Emergent hemostatic treatment is required in CBS developing severe hemorrhage. However, within irradiation fields, temporal embolization devices hardly lead to complete resolution. This is due to the deteriorated condition of the vascular wall incapable to enduring the expansion power of coils, stents or balloons. Bypass grafting is also

  17. Transarterial endovascular treatment in the management of life-threatening carotid blowout syndrome in head and neck cancer patients: review of the literature.

    Science.gov (United States)

    Dequanter, D; Shahla, M; Paulus, P; Aubert, C; Lothaire, P

    2013-12-01

    Carotid blowout syndrome is a rare but devastating complication in patients with head and neck malignancy, and is associated with high morbidity and mortality. Bleeding from the carotid artery or its branches is a well-recognized complication following treatment or recurrence of head and neck cancer. It is an emergency situation, and the classical approach to save the patient's life is to ligate the carotid artery. But the surgical treatment is often technically difficult. Endovascular therapies were recently reported as good alternatives to surgical ligation. Retrospective review of three cases of acute or threatened carotid hemorrhage managed by endovascular therapies. Two patients presented with acute carotid blowout, and one patient with a sentinel bleed. Two patients had previously been treated with surgery and chemo radiation. One patient was treated by chemo radiation. Two had developed pharyngocutaneous fistulas, and one had an open necrosis filled wound that surrounded the carotid artery. In two patients, stent placement resolved the acute hemorrhage. In one patient, superselective embolization was done. Mean duration follow-up was 10.2 months. No patient had residual sequelae of stenting or embolization. Management of carotid blow syndrome is very critical and difficult. A multidisciplinary approach is very important in the management of carotid blow syndrome. Correct and suitable management can be life saving. An endovascular technique is a good and effective alternative with much lower morbidity rates than surgical repair or ligation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. An unusual case of aortic rupture after deployment of a bare stent in the treatment of aortic dissection in a patient with giant-cell arteritis.

    Science.gov (United States)

    Rynio, Pawel; Kazimierczak, Arkadiusz; Gutowski, Piotr; Cnotliwy, Miloslaw

    2017-06-01

    Giant-cell arteritis is associated with a higher risk of aortic aneurysm and aortic dissection formation. We present a women with aortic dissection type B treated with a stent graft and bare-metal stent implantation. After the stent deployment we noticed aortic rupture, which was successfully treated with implantation of an additional stent graft. This report highlights the difficulty of endovascular therapy in patients with giant-cell arteritis. We have to bear in mind that chronic inflammation of the aorta leads to a more fragile aortic wall than normal. We recommend the use of a stent graft over a bare-metal stent and gentle use of a balloon catheter.

  19. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  20. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  1. An intriguing design concept to enhance the pulsatile fatigue life of self-expanding stents.

    Science.gov (United States)

    Hsiao, Hao-Ming; Yin, Ming-Ting

    2014-02-01

    Intravascular stenting has emerged as the primary treatment for vascular diseases and has received great attention from the medical community since its introduction two decades ago. The endovascular self-expanding stent is used to treat peripheral artery diseases; however, once implanted, these stents suffer from various cyclic motions caused by pulsatile blood pressure and daily activities. Due to this challenging environment, fatigue performance has become a critical issue for stent design. In this paper, a simple yet intriguing concept of stent design aimed at enhancing pulsatile fatigue life is investigated. The concept of this design is to shift the highly concentrated stresses/strains away from the crown and re-distribute them along the stress-free bar arm by tapering its strut width. Finite element models were developed to evaluate the mechanical integrity and pulsatile fatigue resistance of the stent to various loading conditions. Results show that the fatigue safety factor jumped to 2.5-3.0 times that of the standard stent with constant strut width. This is astonishing considering that the stent profile and scaffolding were not compromised. The findings of this paper provide an excellent approach to the optimization of future stent design to greatly improve stent fatigue performance.

  2. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  3. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  4. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, F.A.B.; Spithoven, J.H.; Zeebregts, C.J.A.; Scharn, D.M.; Reijnen, M.M.

    2015-01-01

    PURPOSE: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. MATERIALS AND METHODS: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  5. Endovascular Treatment of Occlusive Lesions in the Aortic Bifurcation with Kissing Polytetrafluoroethylene-Covered Stents

    NARCIS (Netherlands)

    Grimme, Frederike A. B.; Spithoven, J. Hans; Zeebregts, Clark J.; Scharn, Dirk M.; Reijnen, Michel M. P. J.

    Purpose: To determine the clinical outcomes of polytetrafluoroethylene covered balloon expandable stents (CBESs) in occlusive lesions of the aortic bifurcation in a kissing stent configuration. Materials and Methods: The study included 69 consecutive patients (29 men, 40 women) who underwent kissing

  6. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  7. Endovascular Repair of a Pseudoaneurysm of the Abdominal Aorta Secondary to Translumbar Aortography

    International Nuclear Information System (INIS)

    Mir, Naheed; Nunzio, Mario De; Pollock, John G

    2006-01-01

    This report describes an incidental finding of a pseudoaneurysm of the abdominal aorta on a computed tomography (CT) renal angiogram during investigation of chronic renal failure in a 73-year-old man. The patient had undergone a translumbar aortogram 20 years previously. An increase in the size of the aneurysm by 7 mm over 6 months prompted treatment and the aneurysm underwent successful endovascular repair with a custom-made stent-graft

  8. Sheath rendezvous method: a novel distal protection technique during endovascular treatment of subclavian artery occlusions.

    Science.gov (United States)

    Haraguchi, Takuya; Urasawa, Kazushi; Nakama, Tatsuya; Nakagawa, Yuya; Tan, Michinao; Koshida, Ryoji; Sato, Katsuhiko

    2016-10-01

    To describe an innovative distal protection technique, "sheath rendezvous method", during endovascular treatment for subclavian arterial occlusions. 4.5F and 6F guiding sheath were inserted from left brachial and common femoral artery, respectively. 0.014″ guidewire retrogradely passed through occlusion and into antegrade sheath to establish a pull-through system. 3.0 mm balloon was used to expand occlusion and anchor to deliver retrograde sheath into antegrade one. Both sheaths locked by balloon dilatation crossed occlusion until antegrade sheath passed over lesion. Balloon expandable stent was delivered within antegrade sheath. Sheath was removed, and stent was implanted. We obtained an excellent outcome without complications.

  9. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  10. Automated peroperative assessment of stents apposition from OCT pullbacks.

    Science.gov (United States)

    Dubuisson, Florian; Péry, Emilie; Ouchchane, Lemlih; Combaret, Nicolas; Kauffmann, Claude; Souteyrand, Géraud; Motreff, Pascal; Sarry, Laurent

    2015-04-01

    This study's aim was to control the stents apposition by automatically analyzing endovascular optical coherence tomography (OCT) sequences. Lumen is detected using threshold, morphological and gradient operators to run a Dijkstra algorithm. Wrong detection tagged by the user and caused by bifurcation, struts'presence, thrombotic lesions or dissections can be corrected using a morphing algorithm. Struts are also segmented by computing symmetrical and morphological operators. Euclidian distance between detected struts and wall artery initializes a stent's complete distance map and missing data are interpolated with thin-plate spline functions. Rejection of detected outliers, regularization of parameters by generalized cross-validation and using the one-side cyclic property of the map also optimize accuracy. Several indices computed from the map provide quantitative values of malapposition. Algorithm was run on four in-vivo OCT sequences including different incomplete stent apposition's cases. Comparison with manual expert measurements validates the segmentation׳s accuracy and shows an almost perfect concordance of automated results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Transjugular Endovascular Recanalization of Splenic Vein in Patients with Regional Portal Hypertension Complicated by Gastrointestinal Bleeding

    International Nuclear Information System (INIS)

    Luo, Xuefeng; Nie, Ling; Wang, Zhu; Tsauo, Jiaywei; Tang, Chengwei; Li, Xiao

    2014-01-01

    PurposeRegional portal hypertension (RPH) is an uncommon clinical syndrome resulting from splenic vein stenosis/occlusion, which may cause gastrointestinal (GI) bleeding from the esophagogastric varices. The present study evaluated the safety and efficacy of transjugular endovascular recanalization of splenic vein in patients with GI bleeding secondary to RPH.MethodsFrom December 2008 to May 2011, 11 patients who were diagnosed with RPH complicated by GI bleeding and had undergone transjugular endovascular recanalization of splenic vein were reviewed retrospectively. Contrast-enhanced computed tomography revealed splenic vein stenosis in six cases and splenic vein occlusion in five. Etiology of RPH was chronic pancreatitis (n = 7), acute pancreatitis with pancreatic pseudocyst (n = 2), pancreatic injury (n = 1), and isolated pancreatic tuberculosis (n = 1).ResultsTechnical success was achieved in 8 of 11 patients via the transjugular approach, including six patients with splenic vein stenosis and two patients with splenic vein occlusion. Two patients underwent splenic vein venoplasty only, whereas four patients underwent bare stents deployment and two covered stents. Splenic vein pressure gradient (SPG) was reduced from 21.5 ± 7.3 to 2.9 ± 1.4 mmHg after the procedure (P < 0.01). For the remaining three patients who had technical failures, splenic artery embolization and subsequent splenectomy was performed. During a median follow-up time of 17.5 (range, 3–34) months, no recurrence of GI bleeding was observed.ConclusionsTransjugular endovascular recanalization of splenic vein is a safe and effective therapeutic option in patients with RPH complicated by GI bleeding and is not associated with an increased risk of procedure-related complications

  12. Transjugular Endovascular Recanalization of Splenic Vein in Patients with Regional Portal Hypertension Complicated by Gastrointestinal Bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xuefeng; Nie, Ling; Wang, Zhu; Tsauo, Jiaywei; Tang, Chengwei; Li, Xiao, E-mail: simonlixiao@126.com [West China Hospital, Sichuan University, Department of Gastroenterology (China)

    2013-05-02

    PurposeRegional portal hypertension (RPH) is an uncommon clinical syndrome resulting from splenic vein stenosis/occlusion, which may cause gastrointestinal (GI) bleeding from the esophagogastric varices. The present study evaluated the safety and efficacy of transjugular endovascular recanalization of splenic vein in patients with GI bleeding secondary to RPH.MethodsFrom December 2008 to May 2011, 11 patients who were diagnosed with RPH complicated by GI bleeding and had undergone transjugular endovascular recanalization of splenic vein were reviewed retrospectively. Contrast-enhanced computed tomography revealed splenic vein stenosis in six cases and splenic vein occlusion in five. Etiology of RPH was chronic pancreatitis (n = 7), acute pancreatitis with pancreatic pseudocyst (n = 2), pancreatic injury (n = 1), and isolated pancreatic tuberculosis (n = 1).ResultsTechnical success was achieved in 8 of 11 patients via the transjugular approach, including six patients with splenic vein stenosis and two patients with splenic vein occlusion. Two patients underwent splenic vein venoplasty only, whereas four patients underwent bare stents deployment and two covered stents. Splenic vein pressure gradient (SPG) was reduced from 21.5 ± 7.3 to 2.9 ± 1.4 mmHg after the procedure (P < 0.01). For the remaining three patients who had technical failures, splenic artery embolization and subsequent splenectomy was performed. During a median follow-up time of 17.5 (range, 3–34) months, no recurrence of GI bleeding was observed.ConclusionsTransjugular endovascular recanalization of splenic vein is a safe and effective therapeutic option in patients with RPH complicated by GI bleeding and is not associated with an increased risk of procedure-related complications.

  13. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H. [Robert Janker Klinik, Bonn (Germany); Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany); Miloslavski, E.; Lowens, S.; Reinartz, J. [Robert Janker Klinik, Bonn (Germany); Liebig, T.; Kuehne, D. [Alfried Krupp Krankenhaus, Klinik fuer Radiologie und Neuroradiologie, Essen (Germany)

    2005-03-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  14. Treatment of intracranial atherosclerotic stenoses with balloon dilatation and self-expanding stent deployment (WingSpan)

    International Nuclear Information System (INIS)

    Henkes, H.; Miloslavski, E.; Lowens, S.; Reinartz, J.; Liebig, T.; Kuehne, D.

    2005-01-01

    The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% after stent deployment. Arterial dissection, occlusion of the target artery or symptomatic distal emboli was not encountered. In one patient, a side branch occlusion occurred after dilatation of a M1 stenosis, with complete neurological recovery. All patients were either stable or improved 4 weeks after the treatment. Recurrent TIA did not occur in any patient. Balloon dilatation and subsequent deployment of a self-expandable stent for the treatment of symptomatic intracranial arterial stenoses combines the advantages of both techniques and allows a rapid, clinically effective and technically safe treatment of these frequently challenging lesions. (orig.)

  15. Retrograde type A dissection following hybrid supra-aortic endovascular surgery in high-risk patients unfit for conventional open repair.

    Science.gov (United States)

    Yip, Hon C; Chan, Yiu C; Qing, Kai X; Cheng, Stephen W

    2018-04-01

    Hybrid procedures with combined open extra-anatomical supra-aortic bypasses and endovascular surgery are less invasive for patients with complex aortic arch pathology. The aim of this paper is to report patients who developed retrograde type A aortic dissection following initially successful hybrid endovascular treatment. Retrospective review of prospectively collected computerized departmental database. All patients with supra-aortic hybrid endovascular surgery and post-procedure retrograde type A dissection were identified. Patient demographics, comorbid conditions, perioperative parameters, procedural details and post-operative complications were collected. From May 2005 to July 2014, 163 patients underwent thoracic aortic endovascular procedures at our institution. From the 46 patients who had supra-aortic hybrid endovascular repair, six patients (6/46, 13% of all supra-aortic hybrid cases, 3 males) developed retrograde type A aortic dissection. All were elective cases, with 3 chronic dissecting aneurysms and 3 atherosclerotic aneurysms. All had one-stage hybrid procedures: 2 patients had carotid-carotid bypass grafts, one had carotid-carotid-left subclavian bypass graft, and 3 had bypass grafts from ascending aorta to innominate artery and left carotid artery. Five patients had Cook Zenith thoracic stent-grafts (Cook Medical, Bloomington, IN, USA), and one had Medtronic Valiant stent-grafts (Medtronic Vascular Inc, Santa Rosa, CA, USA). The retrograde type A dissection occurred with sudden symptoms at day 5, 6, 10, 20, 105 and 128, respectively. There were 3 immediate fatalities and 2 patients treated conservatively deemed unfit for reintervention (one died of pneumonia at 9 months, and one remained alive at 7 months post-complication). One patient underwent successful emergency open surgery and survived. Supra-aortic hybrid procedures in treating aortic arch pathology may be at risk of developing retrograde type A dissection. This post-operative complication

  16. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  17. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  18. Are drug-coated balloons cost effective for femoropopliteal occlusive disease? A comparison of bare metal stents and uncoated balloons.

    Science.gov (United States)

    Poder, Thomas G; Fisette, Jean-François

    2016-07-01

    To perform a cost-effectiveness analysis to help hospital decision-makers with regard to the use of drug-coated balloons compared with bare metal stents and uncoated balloons for femoropopliteal occlusive disease. Clinical outcomes were extracted from the results of meta-analyses already published, and cost units are those used in the Quebec healthcare network. The literature review was limited to the last four years to obtain the most recent data. The cost-effectiveness analysis was based on a 2-year perspective, and risk factors of reintervention were considered. The cost-effectiveness analysis indicated that drug-coated balloons were generally more efficient than bare metal stents, particularly for patients with higher risk of reintervention (up to CAD$1686 per patient TASC II C or D). Compared with uncoated balloons, results indicated that drug-coated balloons were more efficient if the reintervention rate associated with uncoated balloons is very high and for patients with higher risk of reintervention (up to CAD$3301 per patient). The higher a patient's risk of reintervention, the higher the savings associated with the use of a drug-coated balloon will be. For patients at lower risk, the uncoated balloon strategy is still recommended as a first choice for endovascular intervention.

  19. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    with prosthesis. Three cases developed type III endoleak. Balloon dilation followed by additional stent-graft placement was adopted in one case. Thoracic endovascular aortic repair with subsequent EVAR was carried out in another patient with Stanford type A aortic dissection. Re-examination with CTA was performed 7-10 days after the treatment, and once a year thereafter. Results: EVAR was successfully completed in all patients. The main complications included thrombosis due to vascular kinking (n=1) and disruption of abdominal incision (n=1). No death due to surgery occurred. During the follow-up period of 6 month to 5 years all patients remained alive. Conclusion: With the advantages of high imaging quality and usefulness for accurate measure of parameters, CTA is the gold standard for preoperative and postoperative evaluation. EVAR is a safe and effective treatment for abdominal aortic aneurysm in aged patients with high-risk. (authors)

  20. [Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis].

    Science.gov (United States)

    Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M

    2002-03-01

    To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.

  1. Nursing cooperation in endovascular aneurysm repair treatment for aortic dissection

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan; Chen Rumei; Xiao Zhanqiang; Qi Youfei

    2014-01-01

    Objective: To summarize the main points of nursing cooperation in endovascular aneurysm repair treatment for aortic dissection. Methods: Preoperative psychological care and the other preparations were carefully conducted. During the operation, the patient's body was correctly placed. Active cooperation with the performance of angiography and close observation during heparinization were carried out. The proper delivery of catheter and stent to the operator was carefully done. Close observation for the patient's vital signs, the renal function and the changes of limb blood supply were made. Results: Under close cooperation of' the operators, nurses, anesthesiologists and technicians, the surgery was successfully accomplished in 35 patients. The monitoring of vital signs during the entire performance of operation was well executed. No surgical instruments delivery error's or surgery failure due to unsuitable cooperation occurred. Conclusion: Perfect preoperative preparation, strict nursing cooperation and team cooperation are the key points to ensure a successful endovascular aneurysm repair for aortic dissection. (authors)

  2. Long-term impact of a preclinical endovascular skills course on medical student career choices.

    Science.gov (United States)

    Lee, Jason T; Son, Ji H; Chandra, Venita; Lilo, Emily; Dalman, Ronald L

    2011-10-01

    Surging interest in the 0 + 5 integrated vascular surgery (VS) residency and successful recruitment of the top students in medical school requires early exposure to the field. We sought to determine the impact of a high-fidelity simulation-based preclinical endovascular skills course on medical student performance and ultimate career specialty choices. Fifty-two preclinical medical students enrolled in an 8-week VS elective course from 2007 to 2009. Students completed a baseline and postcourse survey and performed a renal angioplasty/stent procedure on an endovascular simulator (pretest). A curriculum consisting of didactic teaching covering peripheral vascular disease and weekly mentored simulator sessions concluded with a final graded procedure (posttest). Long-term follow-up surveys 1 to 3 years after course completion were administered to determine ultimate career paths of participants as well as motivating factors for career choice. Objective and subjective performance measured on the simulator and through structured global assessment scales improved in all students from pre- to posttest, particularly with regard to technical skill and overall procedural competency (P choices including surgical subspecialties (64%), radiology (10%), and cardiology (6%). Most respondents indicated major reasons for continued interest in VS were the ability to practice endovascular procedures on the simulator (92%) and mentorship from VS faculty (70%). Basic endovascular skills can be efficiently introduced through a simulation-based curriculum and lead to improved novice performance. Early exposure of preclinical medical students provides an effective teaching and recruitment tool for procedural-based fields, particularly surgical subspecialties. Mentored exposure to endovascular procedures on the simulator positively impacts long-term medical student attitudes toward vascular surgery and ultimate career choices. Copyright © 2011 Society for Vascular Surgery. Published by

  3. [Cost-effectiveness trial of self-expandable metal stents and plastic biliary stents in malignant biliary obstruction].

    Science.gov (United States)

    Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán

    2016-02-14

    Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.

  4. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  5. Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Jahnke, T.; Grimm, J.; Behm, C.; Hilbert, C.; Frahm, C.; Biederer, J.; Brossmann, J.; Heller, M.

    2002-01-01

    Objective: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). Patients and Methods: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink TM 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfermoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88% ±10 and 9 mm ±5. Results: Renal stent implantation was technically successful in all cases (100%). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg ± 10 before to 1 mmHg ± 1.8 after the procedure. Remaining stenosis measured 0.7% ±4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n.s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p [de

  6. Physical aspects of endovascular brachytherapy

    International Nuclear Information System (INIS)

    Kirisits, C.

    2001-11-01

    Restenosis is severely limiting the outcome of vascular interventions. In several clinical trials endovascular brachytherapy has shown to reduce the restenosis rate. Local radiotherapy to the injured vessel wall is a promising new type of treatment in order to inhibit a complex wound healing process resulting in cell proliferation and re-obstruction of the treated vessel. Treatment planning has to be based on the dose distribution in the vicinity of the sources used. Source strength was determined in terms of air kerma rate for gamma nuclides (Iridium-192) and absorbed dose to water at reference distance of 2 mm for beta nuclides (Strontium-90/Yttrium-90, Phosphor-32), respectively. Radial dose profiles and the Reference Isodose Length (RIL) were determined using the EGSnrc code and GafChromic film. Good agreement was found between both methods. In order to treat the entire clinical target length, the (RIL) is an essential value during treatment planning. Examples are described for different levels of treatment planing including recommendations for optimal choice and positioning of the radioactive devices inside the artery. IVUS based treatment planning is illustrated with superposition of isodoses on cross-sectional images. A calculation model for radioactive stents is presented in order to determine dose volume histograms in a retrospective analysis. Radiation protection issues for endovascular brachytherapy are discussed in detail. Personal dose for the involved personnel is estimated based on calculations and measurements. Beta ray dosimetry is performed with suitable detectors. In order to estimate the exposure to the patient the dose to organs at risk is calculated and compared to the dose from angiography. There is an additional radiation exposure to patients and personnel caused by endovascular brachytherapy, but the values are much smaller than those caused by diagnostic angiography. (author)

  7. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  8. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    International Nuclear Information System (INIS)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah

    2009-01-01

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease

  9. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2009-07-15

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease.

  10. Endovascular Treatment of a Bleeding Secondary Aorto-Enteric Fistula. A Case Report with 1-Year Follow-up

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vasdekis, Spyros; Kostopanagiotou, Georgia; Danias, Nikolaos; Alexopoulou, Efthymia; Petropoulou, Konstantina; Gouliamos, Athanasios; Perros, Georgios

    2007-01-01

    We report a patient with life-threatening gastrointestinal bleeding caused by a secondary aorto-enteric fistula. Because the patient had several comorbid conditions, we successfully stopped the bleeding by endovascular placement of a bifurcated aortic stent-graft. The patient developed periaortic infection 4 months later, but he was managed with antibiotics. The patient is well 1 year after the procedure

  11. Experimental models of tracheobronchial stenoses: a useful tool for evaluating airway stents.

    Science.gov (United States)

    Marquette, C H; Mensier, E; Copin, M C; Desmidt, A; Freitag, L; Witt, C; Petyt, L; Ramon, P

    1995-09-01

    Stent implantation is a conservative alternative to open operation for treating benign tracheobronchial strictures. Most of the presently available stents were primarily designed for endovascular use. Their respiratory use entails a risk of iatrogenic complications. From a scientific and from an ethical point of view these risks justify preclinical evaluation of new respiratory stents in experimental models of central airway stenoses. Therefore, an attempt was made to develop such models in piglets and adult minipigs. Tracheal stenoses were obtained by creating first a segmental tracheomalacia through extramucosal resection of cartilaginous arches. The fibrous component of the stenoses was then obtained through bronchoscopic application of a caustic agent causing progressive deep mucosal and submucosal injury. Stenoses of the main bronchi were created by topical application of the caustic agent only. These models demonstrated the typical features of benign fibromalacic tracheobronchial stenoses with constant recurrence after mechanical dilation. Preliminary experiments showed that short-term problems of tolerance of stent prototypes are easily demonstrable in these models. These experimental models, which simulate quite realistically human diseases, offer the opportunity to perfect new tracheobronchial stents specifically designed for respiratory use and to evaluate their long-term tolerance before their use in humans.

  12. Fibrosing Mediastinitis: Successful Stenting of the Pulmonary Artery

    Directory of Open Access Journals (Sweden)

    Rennae Thiessen

    2008-01-01

    Full Text Available Fibrosing mediastinitis is a rare benign condition, which can cause compression of the pulmonary or systemic vessels, tracheobronchial tree, coronary arteries or esophagus, leading to disabling clinical symptoms and even death. The case of a 26-year-old woman who presented with dyspnea is described. She was found to have 80% stenosis of the right pulmonary artery secondary to fibrosing mediastinitis. The stenosis was managed successfully with an endovascular Palmaz-Schatz stent, and the patient remains symptom-free 10 years later.

  13. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    Science.gov (United States)

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, pvenous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  14. Tratamento endovascular da síndrome da veia cava superior: relato de caso e revisão da literatura Endovascular treatment of superior vena cava syndrome: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Cardozo

    2006-12-01

    Full Text Available Relatamos o caso de uma paciente portadora de síndrome da veia cava superior sintomática de origem benigna tratada pela técnica endovascular. A angiorressonância magnética pré-angioplastia evidenciou extensa trombose do tronco braquiocefálico esquerdo, da veia subclávia esquerda e obstrução da veia cava superior junto ao tronco braquiocefálico direito. A paciente realizou mastectomia radical 2 anos antes, associada à quimioterapia e radioterapia do tórax. Foram realizados angioplastia venosa e implante de stent expansível por balão. O resultado foi satisfatório, com alívio imediato dos sintomas devido à recanalização da veia cava superior e do tronco braquiocefálico direito. Foi instituída anticoagulação oral. A paciente permanece sem recidiva dos sintomas após 8 meses de acompanhamento. O tratamento endovascular é uma alternativa terapêutica com baixa morbidade e resultado satisfatório a médio prazo que pode ser oferecida aos pacientes portadores de síndrome da veia cava superior.We report a case of a patient with symptomatic benign superior vena cava syndrome treated by the endovascular technique. The angiographic resonance before angioplasty showed extensive thrombosis of the left brachiocephalic trunk, left subclavian vein and superior vena cava obstruction close to the right brachiocephalic trunk. The patient underwent radical mastectomy 2 years ago with adjuvant chemotherapy and chest radiotherapy. Venous angioplasty and balloon-expandable stenting were performed. Satisfactory result was obtained with immediate relief of symptoms due to recanalization of the right brachiocephalic trunk and superior vena cava. Oral anticoagulation was initiated. The patient is still asymptomatic after 8 months of follow-up. The endovascular treatment is a therapeutic alternative with low morbidity and satisfactory mid-term results that can be offered to patients with superior vena cava syndrome.

  15. The study of metal stents for effect to the radiation therapy

    International Nuclear Information System (INIS)

    Gao Li; Feng Ningyuan; Zhai Renyou; Yang Weizhi; Xu Guozhen; Wang Yafei

    2001-01-01

    Objective: To confirm whether the metal stents affect the radiation beam. Methods: The transmission factors from the national self-expanding esophagus stent, stainless self-expanding bile duct stent, and balloon-expanded vascular stent was supervised under 192 Ir irradiation in the air. Results: The transmission factors from the 3 kinds of metal stents were 0.993, 0.988, and 0.997, which meant that the attenuation of the stents to the radiation was 0.7%, 1.2%, and 0.3%, respectively (mean: 0.7%). Conclusion: The effect of the metal stents to the radiation was less than 1.2% and that meant there was no clinical significant effect on the patients irradiated following stent implantation or to perform the intra-stents brachytherapy

  16. Endovascular treatment of radiation-induced petrous internal carotid artery aneurysm presenting with acute haemorrhage. A report of two cases

    International Nuclear Information System (INIS)

    Cheng, K.-M.; Chiu, H.-M.; Chan, C.-M.; Cheung, Y.-L.; Tang, K.-W.; Law, C.-K.

    2001-01-01

    Hemorrhage from rupture of petrous ICA aneurysm can be life threatening and emergency treatment is required. We report 2 cases of radiation-induced petrous internal carotid artery (ICA) aneurysm presenting with acute hemorrhage (epistaxis and otorrhagia) after radiotherapy (RT) for nasopharyngeal carcinoma (NPC). Both patients had a history of RT treatment for NPC. The first patient, a 54-year-old man, presented with sudden severe epistaxis and hemorrhagic shock. The second patient, a 35-year-old man, presented with episodes of severe otorrhagia. The first patient was immediately resuscitated. Obliteration of the aneurysm was performed by endovascular occlusion of the ICA with Guglielmi detachable coils and fibered platinum coils. For the second patient, the aneurysm was treated by deploying a self-expandable stent across the aneurysm neck. In an emergency situation, ruptured petrous ICA aneurysm can be treated with endovascular occlusion of the ICA with micro-coils if there is a good collateral blood flow. Alternatively, the aneurysm can be treated by deployment of a stent, which can induce stasis and eventual thrombosis of the aneurysm. (author)

  17. Reversal of end-stage renal disease after aortic dissection using renal artery stent: a case report

    Directory of Open Access Journals (Sweden)

    Parikh Chirag R

    2004-05-01

    Full Text Available Abstract Background Medical management is the conventional treatment for Stanford Type B aortic dissections as surgery is associated with significant morbidity and mortality. The advent of endovascular interventional techniques has revived interest in treating end-organ complications of Type B aortic dissection. We describe a patient who benefited from endovascular repair of renal artery stenosis caused by a dissection flap, which resulted in reversal of his end-stage renal disease (ESRD. Case presentation A 69 y/o male with a Type B aortic dissection diagnosed two months earlier was found to have a serum creatinine of 15.2 mg/dL (1343.7 μmol/L on routine visit to his primary care physician. An MRA demonstrated a rightward spiraling aortic dissection flap involving the origins of the celiac artery, superior mesenteric artery, and both renal arteries. The right renal artery arose from the false lumen with lack of blood flow to the right kidney. The left renal artery arose from the true lumen, but an intimal dissection flap appeared to be causing an intermittent stenosis of the left renal artery with compromised blood flow to the left kidney. Endovascular reconstruction with of the left renal artery with stent placement was performed. Hemodialysis was successfully discontinued six weeks after stent placement. Conclusion Percutaneous intervention provides a promising alternative for patients with Type B aortic dissections when medical treatment will not improve the likelihood of meaningful recovery and surgery entails too great a risk. Nephrologists should therefore be aggressive in the workup of ischemic renal failure associated with aortic dissection as percutaneous intervention may reverse the effects of renal failure in this population.

  18. The 100 most cited articles in the endovascular management of intracranial aneurysms.

    Science.gov (United States)

    Maingard, Julian; Phan, Kevin; Ren, Yifan; Kok, Hong Kuan; Thijs, Vincent; Hirsch, Joshua A; Lee, Michael J; Chandra, Ronil V; Brooks, Duncan Mark; Asadi, Hamed

    2018-01-19

    Endovascular interventions for intracranial aneurysms have evolved substantially over the past several decades. A citation rank list is used to measure the scientific and/or clinical impact of an article. Our objective was to identify and analyze the characteristics of the 100 most cited articles in the field of endovascular therapy for intracranial aneurysms. We performed a retrospective bibliometric analysis between July and August 2017. Articles were searched on the Science Citation Index Expanded database using Web of Science in order to identify the most cited articles in the endovascular therapy of intracranial aneurysms since 1945. Using selected key terms ('intracranial aneurysm', 'aneurysm', 'aneurysmal subarachnoid', 'endovascular', 'coiling', 'stent-assisted', 'balloon-assisted', 'flow-diversion') yielded a total of 16 314 articles. The top 100 articles were identified and analyzed to extract relevant information, including citation count, authorship, article type, subject matter, institution, country of origin, and year of publication. Citations for the top 100 articles ranged from 133 to 1832. All articles were cited an average of 27 times per year. There were 45 prospective studies, including 7 level-II randomized controlled trials. Most articles were published in the 2000s (n=53), and the majority constituted level III or level IV evidence. Half of the top 100 articles arose from the USA. This study provides a comprehensive overview of the most cited articles in the endovascular management of intracranial aneurysms. It recognizes the contributions made by key authors and institutions, providing an important framework to an enhanced understanding of the evidence behind the endovascular treatment of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    Directory of Open Access Journals (Sweden)

    KS Madhusudhan

    2013-01-01

    Full Text Available Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, successfully treated by self-expandable metallic stent.

  20. A novel intracranial enterprise stent together with colis for the treatment of very small intracranial wide-necked aneurysms

    International Nuclear Information System (INIS)

    Huang Haidong; Zhao Kai; Gu Jianwen; Qu Yan; Yang Tao; Xia Xun; Lin Long; Zhang Hui

    2010-01-01

    Objective: To make a preliminary investigation and summary of the technique and efficacy of the novel intracranial stent, Enterprise, together with hydro-detachable coils for the treatment of very small intracranial wide-necked aneurysms (diameter < 3 mm and body-to-neck ratio < 1.5). Methods: Six cases with very small intracranial wide-necked aneurysms were treated with Enterprise stents and hydrodetachable coils. In 5 cases the Enterprise stent was implanted to cover the neck of the aneurysm, which was followed by the introduction of a microcatheter into the aneurysmal sac through the stent mesh to stuff hydrodetachable coils in order to fill the aneurysmal sac. In the remaining case, the microcatheter was placed into the aneurysmal sac before the Enterprise stent was inserted to embolize the aneurysm. Postoperative follow-up was conducted for 3-6 months. Results: The operation was successfully completed in all 6 patients, with the implanted stents being in right place. The parent arteries remained patency in all patients. No complications occurred. Complete occlusion of aneurysmal cavity was obtained in four cases, and the occlusion degree of the aneurysmal cavity above 95% was seen in 2 cases. After the procedure, all the patients recovered well. Neither rebleeding nor symptoms related to thrombosis occurred during a clinic followup of 3-6 months. Conclusion: Endovascular embolization with Enterprise stent together with hydrodetachable coils is a safe and effective method for the treatment of very small intracranial wide-necked aneurysms.However, its long-term effect needs to be further observed. (authors)

  1. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  2. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  3. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  4. Decreased hyperintense vessels on FLAIR images after endovascular recanalization of symptomatic internal carotid artery occlusion

    International Nuclear Information System (INIS)

    Liu Wenhua; Yin Qin; Yao Lingling; Zhu Shuanggen; Xu Gelin; Zhang Renliang; Ke Kaifu; Liu Xinfeng

    2012-01-01

    Background and purpose: Hyperintense vessels (HV) on fluid-attenuated inversion recovery (FLAIR) images were assumed to be explained by slow antegrade or retrograde leptomeningeal collateral flow related to extracranial or intracranial artery steno-occlusion. The aim of this study was to investigate the effect of recanalization after endovascular therapy of symptomatic internal carotid artery (ICA) occlusion on the presence of HV. Methods: Eleven patients with symptomatic ICA occlusion were retrospectively enrolled. Changes in the HV on FLAIR images were examined in affected hemisphere of each patient after successful treatment with endovascular recanalization (angioplasty, n = 3; stent-assisted angioplasty, n = 8). The relationship between postoperative changes in the HV and Thrombolysis In Cerebral Ischemia (TICI) scale (I-III) was assessed. Results: After operation, HV of the 11 affected hemispheres were showed to be decreased (n = 3) or disappeared (n = 8) in treated side. The median interval between pre- and postoperative MRI examinations was 97.0 h (range, from 69. to 48.7 h). Of the 8 patients with disappeared HV, 7 achieved high TICI grade flow (III) and 1 had relatively low TICI grade flow (IIc) in treated side. However, all the 3 patients with decreased HV were found to be relatively low TICI grade flow (IIc). Conclusion: Our data indicate that endovascular recanalization of ICA occlusion was effective for decreasing HV. Postoperative decrease in HV can be considered as a marker for hemodynamic improvement.

  5. Prevention of paraplegia after endovascular exclusion for stanford B thoracic aortic dissection aneurism

    International Nuclear Information System (INIS)

    Feng Rui; Jing Zaiping; Bao Junmin; Zhao Zhiqing; Zhao Jun; Feng Xiang; Lu Qingsheng; Huang Cheng

    2003-01-01

    Objective: To assess the prophylactic measures of paraplegia and paralysis after endovascular graft exclusion (EVE) for Stanford B thoracic aortic dissections (TAD). Methods: The records of 116 consecutive patients undergoing endovascular TAD repair from 1998 to 2001 were retrospectively reviewed. Steroids were administrated postoperatively in high risk patients likely to be candidates for paraplegia or paralysis. Results: No paraplegia or paralysis occurred postoperatively in all cases, including the patient undergone selective spinal artery angiography (SSAA). Conclusions: Transluminal repair can avoid spinal cord ischemia due to aortic cross-clamping, there is still a risk of spinal cord injury caused by occlusion of intercostal arteries under the cover of endograft. A combination of the prophylactic measures, including SSAA and steroids, have been able to reduce the risk of paraplegia and paralysis. A graft-stent of appropriate length is the key point of this procedure

  6. Endovascular management of recurrent stenosis following left renal vein transposition for the treatment of Nutcracker syndrome.

    Science.gov (United States)

    Baril, Donald T; Polanco, Patricio; Makaroun, Michel S; Chaer, Rabih A

    2011-04-01

    Nutcracker syndrome is an entity resulting from left renal vein compression by the superior mesenteric artery and the aorta, leading to symptoms of left flank pain and hematuria. Conventional treatment has been surgical, commonly through transposition of the left renal vein to a more caudal location on the inferior vena cava. Additionally, endovascular approaches, primarily via renal vein stenting, have been described for treatment of this syndrome. We report the case of a patient with Nutcracker syndrome who underwent successful left renal vein transposition but then developed recurrent symptoms 10 months postoperatively and was successfully treated with angioplasty and stenting. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  7. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  8. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  9. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  10. Flow-diverting Stent in the Treatment of Cervical Carotid Dissection and Pseudoaneurysm: Review of Literature and Case Report.

    Science.gov (United States)

    Baptista-Sincos, Anna Paula Weinhardt; Simplício, Aline Bigatão; Sincos, Igor Rafael; Leaderman, Alex; Neto, Fernando Saliture; Moraes, Adjaldes; Aun, Ricardo

    2018-01-01

    The endovascular technique has been recommended over the past few years to extracranial carotid dissection and pseudoaneurysm with promising results, especially after medical therapy failure. Flow-diverting stents are an alternative for complex cases. These stents have proven to be effective treatment devices for intracranial aneurysms. The reference list of Pham's systematic review, published in 2011, and Seward's literature review, published in 2015, was considered, as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE and Literatura Latino-Americana e do Caribe em Ciências da Saúde. For carotid dissection and pseudoaneurysm, our review yielded 3 published articles including 12 patients. The technical success rate of flow-diverting stent was 100% with no procedural complication described. Mean clinical follow-up was 27.2 months (range 5-48), and in 5 months' angiographic follow-up, all lesions had healed. No new neurological events were reported during the clinical follow-up. Flow diverter stent use on intracranial and peripheral vascular surgery demonstrates satisfactory initial results, but it is still under investigation. There are very few cases treated till now and the initial results with flow-diverting stents to cervical carotid dissection are promising. In well-selected cases, where simple embolization or conventional stent is not appropriate, this technic may be considered. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. PERFORMANCE EVALUATION OF ENDOVASCULAR MYOCARDIUM REVASCULARIZATION IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    I. G. Ryadovoy

    2012-01-01

    Full Text Available Coronary artery stenting was performed at 75 renal transplant recipients. Diffuse multiple and expressed calcified coronary artery disease took place that created many difficulties during the procedures. In result of endovascular treatments positive dynamics of clinical condition in the nearest postoperative period was marked, tolerance to physical exercise was increased and according to this the functional class of angina was reduced. Cardiac and general mortality after treatment in comparison to the data of foreign authors was lower and comparable with demographic death rate of the population for persons of the same sex and age. 

  12. Takayasu arteritis with middle aortic syndrome and mesenteric ischemia treated by aortic stenting

    Directory of Open Access Journals (Sweden)

    Sarah Morrissey, MD, MA, FRCSC

    2017-09-01

    Full Text Available A 48-year-old woman suffering from Takayasu arteritis presented with middle aortic syndrome consisting of abdominal pain, refractory hypertension with pulmonary edema and pleural effusions, and lower limb ischemia. She failed to improve with high-dose steroid therapy and underwent endovascular stenting of two severe stenoses in the supraceliac and infrarenal aorta. Her symptoms resolved and hypertension improved after the procedure.

  13. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  14. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Rajan, Dheeraj K.; Saluja, Jasdeep S.

    2007-01-01

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm. The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  15. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    International Nuclear Information System (INIS)

    Raupach, J.; Lojik, M.; Chovanec, V.; Renc, O.; Strýček, M.; Dvořák, P.; Hoffmann, P.; Guňka, I.; Ferko, A.; Ryška, P.; Omran, N.; Krajina, A.; Čabelková, P.; Čermáková, E.; Malý, R.

    2016-01-01

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due to a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %

  16. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    Energy Technology Data Exchange (ETDEWEB)

    Raupach, J., E-mail: janraupach@seznam.cz; Lojik, M., E-mail: miroslav.lojik@fnhk.cz; Chovanec, V., E-mail: chovanec.v@seznam.cz; Renc, O., E-mail: ondrejrenc@seznam.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Strýček, M., E-mail: m.strycek@gmail.com [Faculty of Medicine at Charles University (Czech Republic); Dvořák, P., E-mail: petr.dvorak@fnhk.cz; Hoffmann, P., E-mail: hoffmpet@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Guňka, I., E-mail: gunka@email.cz; Ferko, A., E-mail: a.ferko@seznam.cz [Faculty of Medicine at Charles University and University Hospital, Department of Surgery (Czech Republic); Ryška, P., E-mail: ryska@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Omran, N., E-mail: nidal81@gmail.com [Faculty of Medicine at Charles University and University Hospital, Department of Cardiac Surgery (Czech Republic); Krajina, A., E-mail: krajina@fnhk.cz; Čabelková, P., E-mail: pavla.cabelkova@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Čermáková, E., E-mail: cermakovae@lfhk.cuni.cz [Faculty of Medicine at Charles University, Computer Technology Center (Czech Republic); Malý, R., E-mail: malyr@volny.cz [Faculty of Medicine at Charles University and University Hospital, Department of Medicine (Czech Republic)

    2016-02-15

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due to a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %.

  17. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  18. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-01-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746

  19. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance.

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-05-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.

  20. A suggested training programme for carotid artery stenting (CAS)

    International Nuclear Information System (INIS)

    Gaines, Peter; Nicholson, Tony

    2006-01-01

    Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety

  1. The effect of stent coating on stent deliverability: direct randomised comparison of drug eluting and bare metal stents using the same stent platform.

    Science.gov (United States)

    Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur

    2012-01-01

    There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect

  2. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  3. The effect of stent structure changes on the hemodynamics and the formation of in-stent restenosis

    International Nuclear Information System (INIS)

    Wu Xia; Xu Ke; Xiao Liang; Zhang Xitong; Su Hongying; Feng Bo

    2009-01-01

    Objective: To investigate the effect of stent structure changes on the formation of in-stent restenosis by studying the influence of these changes on the shear force to the vascular wall, on the velocity of flow and on the flow pattern. Methods: Five stent models were established by using Pro/engineer wildfire 3.0. Model A was regarded as control structure. On the base structure of model A, transverse link component was added to form model B, and vertical link component was added to form model C. The thickness of model D was twice than that of model A, and the meshes density of model E was twice than that of model A. Fluid models were built up by importing these stent models into computational fluid dynamics (CFD) software ansys11.0-CFX, then, CFD analysis was proceeded to study the effect of stent structure on hemodynamics. Results: After the stents were implanted, the percentage of low wall shear stress on the surface of model A, B, C, D and E was 7.78%, 6.65%, 1.48%, 16.52% and 12.12%, respectively. The percentage of D and E was obviously larger than that of A, while the percentage of B was markedly smaller than that of A. The velocity vector on the cross-sectional planes showed that the low velocity and eddy areas in D and E were much larger than that in A, while this area in C was smaller than that in A. Conclusion: The stent structure changes can cause obvious changes in hemodynamics in the implanted vessels. The increase in the thickness and meshes density of the stent is the main factor that induces the formation of low wall shear stress, which will precipitate the development of in-stent restenosis. The added vertical link component will reduce the area of low wall shear stress as well as the occurrence of in-stent restenosis. (authors)

  4. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  5. Diffusion-Weighted Imaging-Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Bond, K M; Brinjikji, W; Murad, M H; Kallmes, D F; Cloft, H J; Lanzino, G

    2017-02-01

    Endovascular treatment of intracranial aneurysms is associated with the risk of thromboembolic ischemic complications. Many of these events are asymptomatic and identified only on diffusion-weighted imaging. We performed a systematic review and meta-analysis to study the incidence of DWI positive for thromboembolic events following endovascular treatment of intracranial aneurysms. A comprehensive literature search identified studies published between 2000 and April 2016 that reported postprocedural DWI findings in patients undergoing endovascular treatment of intracranial aneurysms. The primary outcome was the incidence of DWI positive for thromboembolic events. We examined outcomes by treatment type, sex, and aneurysm characteristics. Meta-analyses were performed by using a random-effects model. Twenty-two studies with 2148 patients and 2268 aneurysms were included. The overall incidence of DWI positive for thromboembolic events following endovascular treatment was 49% (95% CI, 42%-56%). Treatment with flow diversion trended toward a higher rate of DWI positive for lesions than coiling alone (67%; 95% CI, 46%-85%; versus 45%; 95% CI, 33%-56%; P = .07). There was no difference between patients treated with coiling alone and those treated with balloon-assisted (44%; 95% CI, 29%-60%; P = .99) or stent-assisted (43%; 95% CI, 24%-63%; P = .89) coiling. Sex, aneurysm rupture status, location, and size were not associated with the rate of DWI positive for lesions. One in 2 patients may have infarcts on DWI following endovascular treatment of intracranial aneurysms. There is a trend toward a higher incidence of DWI-positive lesions following treatment with flow diversion compared with coiling. Patient demographics and aneurysm characteristics were not associated with DWI-positive thromboembolic events. © 2017 by American Journal of Neuroradiology.

  6. Effect of general anaesthesia on functional outcome in patients with anterior circulation ischaemic stroke having endovascular thrombectomy versus standard care: a meta-analysis of individual patient data.

    Science.gov (United States)

    Campbell, Bruce C V; van Zwam, Wim H; Goyal, Mayank; Menon, Bijoy K; Dippel, Diederik W J; Demchuk, Andrew M; Bracard, Serge; White, Philip; Dávalos, Antoni; Majoie, Charles B L M; van der Lugt, Aad; Ford, Gary A; de la Ossa, Natalia Pérez; Kelly, Michael; Bourcier, Romain; Donnan, Geoffrey A; Roos, Yvo B W E M; Bang, Oh Young; Nogueira, Raul G; Devlin, Thomas G; van den Berg, Lucie A; Clarençon, Frédéric; Burns, Paul; Carpenter, Jeffrey; Berkhemer, Olvert A; Yavagal, Dileep R; Pereira, Vitor Mendes; Ducrocq, Xavier; Dixit, Anand; Quesada, Helena; Epstein, Jonathan; Davis, Stephen M; Jansen, Olav; Rubiera, Marta; Urra, Xabier; Micard, Emilien; Lingsma, Hester F; Naggara, Olivier; Brown, Scott; Guillemin, Francis; Muir, Keith W; van Oostenbrugge, Robert J; Saver, Jeffrey L; Jovin, Tudor G; Hill, Michael D; Mitchell, Peter J

    2018-01-01

    General anaesthesia (GA) during endovascular thrombectomy has been associated with worse patient outcomes in observational studies compared with patients treated without GA. We assessed functional outcome in ischaemic stroke patients with large vessel anterior circulation occlusion undergoing endovascular thrombectomy under GA, versus thrombectomy not under GA (with or without sedation) versus standard care (ie, no thrombectomy), stratified by the use of GA versus standard care. For this meta-analysis, patient-level data were pooled from all patients included in randomised trials in PuMed published between Jan 1, 2010, and May 31, 2017, that compared endovascular thrombectomy predominantly done with stent retrievers with standard care in anterior circulation ischaemic stroke patients (HERMES Collaboration). The primary outcome was functional outcome assessed by ordinal analysis of the modified Rankin scale (mRS) at 90 days in the GA and non-GA subgroups of patients treated with endovascular therapy versus those patients treated with standard care, adjusted for baseline prognostic variables. To account for between-trial variance we used mixed-effects modelling with a random effect for trials incorporated in all models. Bias was assessed using the Cochrane method. The meta-analysis was prospectively designed, but not registered. Seven trials were identified by our search; of 1764 patients included in these trials, 871 were allocated to endovascular thrombectomy and 893 were assigned standard care. After exclusion of 74 patients (72 did not undergo the procedure and two had missing data on anaesthetic strategy), 236 (30%) of 797 patients who had endovascular procedures were treated under GA. At baseline, patients receiving GA were younger and had a shorter delay between stroke onset and randomisation but they had similar pre-treatment clinical severity compared with patients who did not have GA. Endovascular thrombectomy improved functional outcome at 3 months both in

  7. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  8. Intrasellar Iatrogenic Carotid Pseudoaneurysm: Endovascular Treatment with a Polytetrafluoroethylene-Covered S tent

    International Nuclear Information System (INIS)

    Vanninen, R. L.; Manninen, H. I.; Rinne, J.

    2003-01-01

    This case illustrates successful treatment of a large postoperative intrasellar pseudoaneurysm with a polytetrafluoroethylene (PTFE)-covered stent. The advantages and potential disadvantages of this novel method of treatment are discussed. A previously healthy 59-year-old man underwent transsphenoidal operative treatment for hypophyseal macroadenoma,complicated by bleeding. On the 17 th postoperative day the patient had profuse arterial bleeding from his nose requiring posterior tamponade. Subsequent angiography of the left internal carotid artery(ICA) revealed a large pseudoaneurysm located intrasellarly, with the orifice in the anteromedial wall in the ophthalmic segment of the ICA.Surgical treatment of the pseudoaneurysm was considered very risky. A12-mm PTFE-covered stent (JoMed, Ulestraten, Netherlands), manually compressed on a PTCA-balloon (Maxxum 4.5/13 mm, Boston Scientific,Ireland) was endovascularly delivered covering the orifice of the pseudoaneurysm. Control angiography immediately after the intervention and one year later revealed no flow into the pseudoaneurysm and the ICA was fully patent. In conclusion, deployment of a PTFE-covered stent proved to be feasible and successful in the treatment of an intrasellariatrogenic ICA pseudoaneurysm. Adequate anticoagulative treatment after the procedure is essential to prevent thrombotic complications

  9. Surgical Repair of a Post-traumatic Arteriovenous Fistula Complicated by Stent-Graft Misplacement

    International Nuclear Information System (INIS)

    Sahin, Sinan; Ciinar, Bayer; Bilgin, Sule N.; Celik, Levent; Eren, Ergin E.

    2005-01-01

    An arteriovenous fistula (AVF) is an abnormal connection between an artery and a vein which may result from a traumatic injury or occur as a congenital abnormality. It may be asymptomatic or may present with a variety of symptoms. Surgical or endovascular treatment can be preferred. We present a case of unsuccessful percutaneous treatment of a femoral AVF due to misplacement of the stent-grafts, necessitating surgical correction

  10. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    International Nuclear Information System (INIS)

    Saad, Wael E. A.; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G.; Kumer, Sean; Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan; Waldman, David L.; Schmitt, Timothy; Matsumoto, Alan H.; Angle, John F.

    2013-01-01

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996–2009). Recipients’ demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were “iatrogenic” (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0–18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  11. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Wael E. A., E-mail: wspikes@yahoo.com; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Kumer, Sean [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Waldman, David L. [University of Rochester Medical Center, Department of Imaging Sciences (United States); Schmitt, Timothy [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Matsumoto, Alan H.; Angle, John F. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States)

    2013-02-15

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996-2009). Recipients' demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were 'iatrogenic' (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0-18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  12. Reasons Underlying the Consent to Endovascular Treatment, Displayed by Patients Diagnosed with Asymptomatic Internal Carotid Artery Stenosis

    OpenAIRE

    Stanišić, Michał-Goran; Rzepa, Teresa

    2014-01-01

    Background Endovascular treatment of internal carotid artery stenosis (ICAS) has gained popularity in recent years. Offering CAS, which is a controversial treatment in asymptomatic disease, may provoke patient distrust of the diagnosis and intervention benefit. The aim of this study was to prove that asymptomatic ICAS patients tend to show an emotional attitude to their illness, and therefore their decisions regarding carotid artery stenting are externally motivated and assessed emotionally. ...

  13. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  14. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  15. Agreement of duplex ultrasonography vs. computed tomography angiography for evaluation of native and in-stent SFA re-stenosis—Findings from a randomized controlled trial

    International Nuclear Information System (INIS)

    Langenberger, Herbert; Schillinger, Martin; Plank, Christina; Sabeti, Schila; Dick, Petra; Cejna, Manfred; Lammer, Johannes; Minar, Erich; Loewe, Christian

    2012-01-01

    Background: Multidetector CT angiography (CTA) is a non-invasive imaging technique for evaluation of peripheral vascular disease. CTA might be particularly useful for assessment of intermediate- and long-term morphological outcome after endovascular treatment. Validation of CTA vs. the current imaging standard, colour Doppler ultrasonography (CDUS), for quantification of native and in-stent re-stenosis in the superficial femoral artery (SFA) is required. Methods: Seventy randomized patients who underwent stent implantation (n = 47) or balloon angioplasty (n = 23) underwent 6-month follow-up with CDUS and CTA. CTA was compared with CDUS in both sub-groups of patients in terms of binary re-stenosis (>50% lumen narrowing) and re-occlusion. Agreement between CTA and CDUS was assessed using Kappa (κ) statistics with 95% confidence intervals, and correlation coefficients. Results: Binary re-stenosis was detected in 16/70 (22.9%) patients by CTA and 17/70 (24.3%) patients by CDUS (κ = 0.88, 95% CI: 0.80–0.96). Re-stenosis rates after balloon angioplasty were 39.1% (9/23) on CTA and CDUS (κ = 0.82, 95% CI: 0.66–0.98), and after stent implantation 14.9% (7/47) on CTA and 17.0% (8/47) on CDUS (κ = 0.92, 95% CI: 0.84–1.00). Re-occlusions were detected in 3/70 (4.3%) patients by both CTA and CDUS (κ = 0.65; 95% CI 0.54–0.76). Significant correlations (r = 0.85, p < 0.001) were noted between degree of re-stenosis on CTA and peak velocity ratio on CDUS. The correlation coefficient was higher in patients after balloon angioplasty (r = 0.94, p < 0.001) than in patients after stent implantation (r = 0.71, p < 0.001). Conclusion: CTA and CDUS show excellent agreement for evaluation of native and in-stent re-stenosis after endovascular treatment of SFA obstructions. CTA is an appropriate non-invasive imaging modality for follow-up after endovascular therapy

  16. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    International Nuclear Information System (INIS)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo

    2014-01-01

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  17. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2014-02-15

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  18. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention

    OpenAIRE

    Baschet, Louise; Bourguignon, Sandrine; Marque, S?bastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    Objective To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. Methods A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117?762 patient-years with 76 randomised trials. The main effectiveness criterion was major c...

  19. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation

  20. Mortality within the endovascular treatment in Stanford type B aortic dissections Mortalidade no tratamento endovascular nas dissecções aórticas tipo B

    Directory of Open Access Journals (Sweden)

    Alexandre Fioranelli

    2011-06-01

    Full Text Available BACKGROUND: Endovascular stent-graft repair of aortic dissections is a relatively new procedure, and although apparently less invasive, the efficacy and safety of this technique have not been fully established. OBJECTIVE: To evaluate mortality in patients with complicated Stanford type B aortic dissections submitted to endovascular treatment. METHODS: Clinical, anatomical, imaging and autopsy data of 23 patients with complicated type B aortic dissections were reviewed from November 2004 to October 2007. The main indications for transluminal thoracic stent-grafting included: persistent pain in spite of medical therapy, signs of distal limb ischemia, signs of aortic rupture, progression of aneurismal dilation of the descending aorta during follow-up (defined as a diameter > 50 mm and the diameter of descending thoracic aorta of 40mm or larger at the onset of aortic dissection. Data were analyzed statistically; all p-values were two-tailed and differences INTRODUÇÃO: O tratamento endovascular na dissecção de aorta é um procedimento relativamente novo e, embora aparentemente menos invasivo, a eficácia e a segurança dessa técnica não estão totalmente estabelecidas. OBJETIVO: Avaliar a mortalidade e complicações nos pacientes submetidos a tratamento endovascular na dissecção de aorta tipo B de Stanford. MÉTODOS: Foram revisados, a partir de novembro de 2004 a outubro de 2007, em estudo clínico, anatômico, de imagens e dados da autopsia de 23 pacientes com dissecção aórtica tipo B. As principais indicações para o procedimento foram: dor persistente apesar da terapia médica, sinais de isquemia distal do membro, sinais de ruptura da aorta, progressão da dilatação do aneurisma da aorta descendente, durante o seguimento (definida como um diâmetro > 5 cm e descendente da aorta torácica de 40 mm ou mais de diâmetro no início da dissecção aórtica. Os dados foram analisados estatisticamente considerados erro alfa de 5%. As vari

  1. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  2. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  3. Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.

    Science.gov (United States)

    Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei

    2013-02-01

    Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0

  4. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses; Diagnostik und endovaskulaere Therapie intrakranieller arterieller Stenosen

    Energy Technology Data Exchange (ETDEWEB)

    Gizewski, E.R. [Universitaetsklinikum Essen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie; Weber, R. [Universitaetsklinikum Essen (Germany). Klinik fuer Neurologie; Forsting, M. [Universitaetsklinikum Giessen und Marburg, Giessen (Germany). Abt. fuer Neuroradiologie

    2011-02-15

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS ({>=} 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  5. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    International Nuclear Information System (INIS)

    De Cock, Erwin; Sapoval, Marc; Julia, Pierre; Lissovoy, Greg de; Lopes, Sandra

    2013-01-01

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of €6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  6. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    Energy Technology Data Exchange (ETDEWEB)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com [United BioSource Corporation, Peri- and Post-Approval Services (Spain); Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Department of Cardiovascular and Interventional Radiology (France); Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Cardiovascular Surgery Department (France); Lissovoy, Greg de, E-mail: gdelisso@jhsph.edu [Johns Hopkins Bloomberg School of Public Health, Department of Health Policy and Management (United States); Lopes, Sandra, E-mail: Sandra.Lopes@CookMedical.com [Cook Medical, Health Economics and Reimbursement (Denmark)

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  7. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    Science.gov (United States)

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare

  8. Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience

    International Nuclear Information System (INIS)

    Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.

    2004-01-01

    Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions

  9. Endovascular Treatment of Chronic Mesenteric Ischemia by Crossing of Two Stents in a Patient with Celiacomesenteric Trunk

    International Nuclear Information System (INIS)

    Khil, Eun Kyung; Lee, Jae Myeong

    2013-01-01

    A 73-year-old woman was presented with a 3-month history of postprandial abdominal pain and weight loss. The patient had an anatomic variant of celiacomesenteric trunk (CMT), with complete occlusion of the superior mesenteric artery (SMA) and significant stenosis of the CMT ostium, resulting in chronic mesenteric ischemia. After several unsuccessful attempts at revascularization of the SMA, celiac artery stenting was performed, followed by SMA stent placement through the previously placed stent mesh into the occlusion site. The patient's symptoms completely resolved after treatment.

  10. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  11. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    Science.gov (United States)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; Pstents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  12. Endovascular Treatment of Chronic Mesenteric Ischemia: Results in 14 Patients

    International Nuclear Information System (INIS)

    Chahid, Tamam; Alfidja, Agaicha T.; Biard, Marie; Ravel, Anne; Garcier, Jean Marc; Boyer, L.

    2004-01-01

    We evaluated immediate and long-term results of percutaneous transluminal angioplasty (PTA) and stent placement to treat stenotic and occluded arteries in patients with chronic mesenteric ischemia. Fourteen patients were treated by 3 exclusive celiac artery (CA) PTAs (2 stentings), 3 cases with both Superior Mesenteric Artery (SMA) and CA angioplasties, and 8 exclusive SMA angioplasties (3 stentings). Eleven patients had atheromatous stenoses with one case of an early onset atheroma in an HIV patient with antiphospholipid syndrome. The other etiologies of mesenteric arterial lesions were Takayashu arteritis (2 cases) and a postradiation stenoses (1 case). Technical success was achieved in all cases. Two major complications were observed: one hematoma and one false aneurysm occurring at the brachial puncture site (14.3%). An immediate clinical success was obtained in all patients. During a follow-up of 1-83 months (mean: 29 months), 11 patients were symptom free; 3 patients had recurrent pain; in one patient with inflammatory syndrome, pain relief was obtained with medical treatment; in 2 patients abdominal pain was due to restenosis 36 and 6 months after PTA, respectively. Restenosis was treated by PTA (postirradiation stenosis), and by surgical bypass (atheromatous stenosis). Percutaneous endovascular techniques are safe and accurate. They are an alternative to surgery in patients with chronic mesenteric ischemia due to short and proximal occlusive lesions of SMA and CA

  13. Reporting standards for angioplasty and stent-assisted angioplasty for intracranial atherosclerosis.

    Science.gov (United States)

    Schumacher, H Christian; Meyers, Philip M; Higashida, Randall T; Derdeyn, Colin P; Lavine, Sean D; Nesbit, Gary M; Sacks, David; Rasmussen, Peter; Wechsler, Lawrence R

    2010-12-01

    Intracranial cerebral atherosclerosis causes ischemic stroke in a significant number of patients. Technological advances over the past 10 years have enabled endovascular treatment of intracranial atherosclerotic stenosis. The number of patients treated with angioplasty or stent-assisted angioplasty for this condition is increasing. Given the lack of universally accepted definitions, the goal of this document is to provide consensus recommendations for reporting standards, terminology, and written definitions when reporting clinical and radiological evaluation, technique, and outcome of endovascular treatment using angioplasty or stent-assisted angioplasty for stenotic and occlusive intracranial atherosclerosis. This article was written under the auspices of Joint Writing Group of the Technology Assessment Committee, Society of Neurolnterventional Surgery, Society of Interventional Radiology; Joint Section on Cerebro-vascular Neurosurgery of the American Association of Neurological Surgeons and Congress of Neurological Surgeons; and the Section of Stroke and Interventional Neurology of the American Academy of Neurology. A computerized search of the National Library of Medicine database of literature (PubMed) from January 1997 to December 2007 was conducted with the goal to identify published endovascular cerebrovascular interventional data in stenotic intracranial atherosclerosis that could be used as benchmarks for quality assessment. We sought to identify those risk adjustment variables that affect the likelihood of success and complications. This document offers the rationale for different clinical and technical considerations that may be important during the design of clinical trials for endovascular treatment of intracranial stenotic and occlusive atherosclerosis. Included in this guidance document are suggestions for uniform reporting standards for such trials. These definitions and standards are primarily intended for research purposes; however, they should

  14. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  15. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  16. Endovascular Treatment of Chronic Mesenteric Ischemia by Crossing of Two Stents in a Patient with Celiacomesenteric Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Khil, Eun Kyung; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2013-06-15

    A 73-year-old woman was presented with a 3-month history of postprandial abdominal pain and weight loss. The patient had an anatomic variant of celiacomesenteric trunk (CMT), with complete occlusion of the superior mesenteric artery (SMA) and significant stenosis of the CMT ostium, resulting in chronic mesenteric ischemia. After several unsuccessful attempts at revascularization of the SMA, celiac artery stenting was performed, followed by SMA stent placement through the previously placed stent mesh into the occlusion site. The patient's symptoms completely resolved after treatment.

  17. Evaluation of the 4-French Pulsar-18 Self-expanding Nitinol Stent in Long Femoropopliteal Lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Hailer, Birgit; Kaeunicke, Matthias; Stahlhoff, Wilhelm-Friedrich; Boese, Dirk; Breuckmann, Frank

    2014-01-01

    To evaluate the patency and the freedom of target lesion revascularization of the 4-French Pulsar-18 self-expandable (SE) nitinol stent for the treatment of long femoropopliteal occlusive disease in a two-center, prospective, all-comers registry with a follow-up period of 12 months. This registry enrolled 36 patients with symptomatic femoropopliteal long lesions for recanalization and implantation of the 4-French Pulsar-18 SE nitinol stent. Routine follow-up examination including duplex ultrasound was performed after 6 and 12 months. Primary patency was defined as no binary restenosis on duplex ultrasound (Peak systolic velocitiy ration (PSVR) Pulsar-18 SE nitinol stent for endovascular intervention of femoropopliteal disease with a mean lesion length of 182.3 ± 51.8 mm showed promising primary patency and fTLR rates after 6 and 12 months. Diabetes and renal insufficiency had no negative impact on the patency rate.

  18. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  19. Influence of Iliac Stenotic Lesions on Blood Flow Patterns Near a Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) Stent Configuration

    NARCIS (Netherlands)

    Jebbink, Erik Groot; Engelhard, Stefan; Lajoinie, Guillaume; de Vries, Jean-Paul P.M.; Versluis, Michel; Reijnen, Michel M.P.J.

    2017-01-01

    Purpose: To investigate the effect of distal stenotic lesions on flow patterns near a covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration used in the treatment of aortoiliac occlusive disease. Method: Laser particle image velocimetry measurements were performed using

  20. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  1. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    Science.gov (United States)

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  2. Patient effective dose from endovascular brachytherapy with 192Ir Sources

    International Nuclear Information System (INIS)

    Perna, L.; Bianchi, C.; Novario, R.; Nicolini, G.; Tanzi, F.; Conte, L.

    2002-01-01

    The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with 192 Ir sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rando phantom. A method has been developed to estimate the mean organ doses for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from coronary treatment were 2.4x10 -2 mSv.GBq -1 .min -1 for lung, 0.9x10 -2 mSv.GBq -1 .min -1 for oesophagus and 0.48x10 -2 mSv.GBq -1 .min -1 for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2x10 -2 mSv.GBq -1 .min -1 for colon, 7.8x10 -2 mSv.GBq -1 .min -1 for stomach and 1.7x10 -2 mSv.GBq -1 .min -1 for liver. Coronary treatment involved an effective dose of 0.046 mSv.GBq -1 .min -1 , whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq -1 .min -1 ; there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low. (author)

  3. CT appearance of complications related to thoracic endovascular aortic repair (TEVAR): a pictorial essay

    International Nuclear Information System (INIS)

    Pua, U.; Tay, K.H.; Tan, B.S.; Htoo, M.M.; Sebastian, M.; Sin, K.; Chua, Y.L.

    2009-01-01

    Thoracic endovascular aortic repair (TEVAR) is a recognized treatment for various diseases involving the thoracic aorta. Patients treated with TEVAR require lifelong surveillance for potential complications, with CT being highly utilized in most centres. Endoleak is the most common complication and can be detected using CT. However, other complications such as stent strut perforations and end organ ischemia can also be detected on CT. The purpose of this pictorial essay is to illustrate the CT appearance of post-TEVAR complications encountered in our institution and to highlight their significance. (orig.)

  4. CT appearance of complications related to thoracic endovascular aortic repair (TEVAR): a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Pua, U. [Singapore General Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Tay, K.H.; Tan, B.S.; Htoo, M.M. [Singapore General Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Sebastian, M. [Singapore General Hospital, Department of General Surgery, Singapore (Singapore); Sin, K.; Chua, Y.L. [National Heart Centre, Department of Cardiothoracic and Vascular Surgery, Singapore (Singapore)

    2009-05-15

    Thoracic endovascular aortic repair (TEVAR) is a recognized treatment for various diseases involving the thoracic aorta. Patients treated with TEVAR require lifelong surveillance for potential complications, with CT being highly utilized in most centres. Endoleak is the most common complication and can be detected using CT. However, other complications such as stent strut perforations and end organ ischemia can also be detected on CT. The purpose of this pictorial essay is to illustrate the CT appearance of post-TEVAR complications encountered in our institution and to highlight their significance. (orig.)

  5. The Barrel vascular reconstruction device for endovascular coiling of wide-necked intracranial aneurysms: a multicenter, prospective, post-marketing study.

    Science.gov (United States)

    Gory, Benjamin; Blanc, Raphaël; Turjman, Francis; Berge, Jérôme; Piotin, Michel

    2018-02-02

    The Barrel vascular reconstruction device (Barrel VRD) is a novel stent with design features that allow endovascular coiling of wide-necked bifurcation aneurysms while preserving adjacent branches, without necessitating dual stent implantation. This study aimed to assess the safety and effectiveness of the Barrel VRD at 12-month follow-up. The Barrel VRD trial is a prospective, multicenter, observational post-marketing registry evaluating the use of the Barrel VRD for treatment of wide-necked bifurcation aneurysms. The primary effectiveness endpoint was successful aneurysm treatment measured by digital subtraction angiography with a Raymond-Roy occlusion grade of 1 or 2 in the absence of retreatment, parent artery stenosis (>50%), or target aneurysm rupture at 12 months. The primary safety endpoint was the absence of neurological death or major stroke at 12 months. Twenty patients were enrolled from December 2013 to December 2014. The device was implanted in 19 patients with 19 aneurysms (8 middle cerebral artery, 4 anterior communicating artery, 1 internal carotid artery terminus, 4 basilar artery aneurysms; mean dome height 5.7±1.91 mm; mean neck length 4.8±1.35 mm, mean dome-to-neck ratio 1.6±2.0). Coiling was performed in all cases. The primary effectiveness endpoint was achieved in 78.9% of subjects (15/19; 12 complete occlusions, 3 neck remnants), and the primary safety endpoint was 5.3% (1/19). This prospective study demonstrates that the Barrel VRD device resulted in ~80% occlusion rates and ~5% rates of neurological complications at 1 year after endovascular treatment of wide-necked bifurcation intracranial aneurysms. REGISTERED CLINICAL TRIAL: NCT02125097;Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Endovascular treatment of stroke. When and How?

    International Nuclear Information System (INIS)

    Mantatzis, M.

    2012-01-01

    different success rates, until the recently published 'SWIFT' trial render the stent retrievers as the best option until now and establish the use of these devices as the preferred method for the mechanical thrombectomy. The effectiveness of endovascular techniques in acute ischemic stroke has been established in many trials. Clinicians however continue to face many challenges in the selection of the most appropriate approach. In conclusion, while IVT remains the standard of care for the few patients presenting early, interventional techniques can play a significant role in a larger population who present much later, fail to improve with IVT, or who do not meet the inclusion criteria for IVT

  7. Guidelines for patient selection and performance of carotid artery stenting.

    Science.gov (United States)

    Bladin, Christopher; Chambers, Brian; New, Gishel; Denton, Michael; Lawrence-Brown, Michael

    2010-06-01

    The endovascular treatment of carotid atherosclerosis with carotid artery stenting (CAS) remains controversial. Carotid endarterectomy remains the benchmark in terms of procedural mortality and morbidity. At present, there are no consensus Australasian guidelines for the safe performance of CAS. We applied a modified Delphi consensus method of iterative consultation between the College representatives on the Carotid Stenting Guidelines Committee (CSGC). Selection of patients suitable for CAS needs careful consideration of clinical and patho-anatomical criteria and cannot be directly extrapolated from clinical indicators for carotid endarterectomy (CEA). Randomized controlled trials (including pooled analyses of results) comparing CAS with CEA for treatment of symptomatic stenosis have demonstrated that CAS is more hazardous than CEA. On current evidence, the CGSC therefore recommends that CAS should not be performed in the majority of patients requiring carotid revascularisation. The evidence for CAS in patients with symptomatic severe carotid stenosis who are considered medically high risk is weak, and there is currently no evidence to support CAS as a treatment for asymptomatic carotid stenosis. The use of distal protection devices during CAS remains controversial with increased risk of clinically silent stroke. The knowledge requirements for the safe performance of CAS include an understanding of the evidence base from randomized controlled trials, carotid and aortic arch anatomy and pathology, clinical stroke syndromes, the differing treatment options for stroke and carotid atherosclerosis, and recognition and management of periprocedural complications. It is critical that all patients being considered for a carotid intervention have adequate pre-procedural neuro-imaging and an independent, standardized neurological assessment before and after the procedure. Maintenance of proficiency in CAS requires active involvement in surgical/endovascular audit and

  8. Comparison of Covered Versus Uncovered Stents for Benign Superior Vena Cava (SVC) Obstruction.

    Science.gov (United States)

    Haddad, Mustafa M; Simmons, Benjamin; McPhail, Ian R; Kalra, Manju; Neisen, Melissa J; Johnson, Matthew P; Stockland, Andrew H; Andrews, James C; Misra, Sanjay; Bjarnason, Haraldur

    2018-05-01

    To identify whether long-term symptom relief and stent patency vary with the use of covered versus uncovered stents for the treatment of benign SVC obstruction. We retrospectively identified all patients with benign SVC syndrome treated to stent placement between January 2003 and December 2015 (n = 59). Only cases with both clinical and imaging follow-up were included (n = 47). In 33 (70%) of the patients, the obstruction was due to a central line or pacemaker wires, and in 14 (30%), the cause was fibrosing mediastinitis. Covered stents were placed in 17 (36%) of the patients, and 30 (64%) patients had an uncovered stent. Clinical and treatment outcomes, complications, and the percent stenosis of each stent were evaluated. Technical success was achieved in all cases at first attempt. Average clinical and imaging follow-up in years was 2.7 (range 0.1-11.1) (covered) and 1.7 (range 0.2-10.5) (uncovered), respectively. There was a significant difference (p = 0.044) in the number of patients who reported a return of symptoms between the covered (5/17 or 29.4%) and uncovered (18/30 or 60%) groups. There was also a significant difference (p = stenosis after stent placement between the covered [17.9% (range 0-100) ± 26.2] and uncovered [48.3% (range 6.8-100) ± 33.5] groups. No significant difference (p = 0.227) was found in the time (days) between the date of the procedure and the date of clinical follow-up where a return of symptoms was reported [covered: 426.6 (range 28-1554) ± 633.9 and uncovered 778.1 (range 23-3851) ± 1066.8]. One patient in the uncovered group had non-endovascular surgical intervention (innominate to right atrial bypass), while none in the covered group required surgical intervention. One major complication (SIR grade C) occurred that consisted of a pericardial hemorrhagic effusion after angioplasty that required covered stent placement. There were no procedure-related deaths. Both covered and uncovered stents can be used for

  9. Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.

    Science.gov (United States)

    Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-05-01

    This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  11. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  12. Outcomes of Endovascular Aneurysm Repair using the Ovation Stent Graft System in Adverse Anatomy.

    Science.gov (United States)

    Greaves, Nicholas S; Moore, Aiden; Seriki, Dare; Ghosh, Jonathan

    2018-04-01

    The aim was the evaluation of mid-term efficacy and safety outcome measures for the Ovation (Endologix, Santa Rosa, CA, USA) stent graft system in the management of infrarenal abdominal aortic aneurysms (iAAA) with adverse anatomy. A retrospective observational study of all patients undergoing elective iAAA repair was carried out from 2012 to 2017 using Ovation Prime or iX stent grafts with a minimum of 3 months follow-up at a single UK vascular centre. Post-operative surveillance involved computed tomography scans at 3 months and 1 year, with duplex ultrasound yearly thereafter. Outcome measures were established with retrospective analysis of pre- and post-operative imaging, and included peri-operative mortality, major adverse events, limb complications, aneurysm diameter change, and endoleak rates. All patients were within Ovation instructions for use (IFU), and assessment was made to determine whether aneurysms had anatomical features considered adverse for other commonly used stent graft platforms. Ovation stent grafts were implanted in 52 patients (79% male, mean age 75.7 years) with a mean aneurysm diameter of 62.5 mm (range 55-107 mm). There was 100% technical deployment success. The 30 day mortality was 0% and there was no aneurysm related mortality during follow-up (median 24 months, range 3-48 months). There were no type I or III endoleaks, but 19% developed type II endoleaks with one patient requiring re-intervention. No iliac limb occlusions were identified but one case required relining for limb kinking. All 52 cases were within the IFU for Ovation but only 12% met the IFU criteria for the Cook and Medtronic devices. The mid-term experience with Ovation demonstrates safe, durable treatment of iAAAs, including those with unfavourable anatomy, frequently off IFU for other commonly used devices. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  13. Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique.

    Science.gov (United States)

    Nevzati, Edin; Rey, Jeannine; Coluccia, Daniel; D'Alonzo, Donato; Grüter, Basil; Remonda, Luca; Fandino, Javier; Marbacher, Serge

    2017-10-01

    The steady progess in the armamentarium of techniques available for endovascular treatment of intracranial aneurysms requires affordable and reproducable experimental animal models to test novel embolization materials such as stents and flow diverters. The aim of the present project was to design a safe, fast, and standardized surgical technique for stent assisted embolization of saccular aneurysms in a rat animal model. Saccular aneurysms were created from an arterial graft from the descending aorta.The aneurysms were microsurgically transplanted through end-to-side anastomosis to the infrarenal abdominal aorta of a syngenic male Wistar rat weighing >500 g. Following aneurysm anastomosis, aneurysm embolization was performed using balloon expandable magnesium stents (2.5 mm x 6 mm). The stent system was retrograde introduced from the lower abdominal aorta using a modified Seldinger technique. Following a pilot series of 6 animals, a total of 67 rats were operated according to established standard operating procedures. Mean surgery time, mean anastomosis time, and mean suturing time of the artery puncture site were 167 ± 22 min, 26 ± 6 min and 11 ± 5 min, respectively. The mortality rate was 6% (n=4). The morbidity rate was 7.5% (n=5), and in-stent thrombosis was found in 4 cases (n=2 early, n=2 late in stent thrombosis). The results demonstrate the feasibility of standardized stent occlusion of saccular sidewall aneurysms in rats - with low rates of morbidity and mortality. This stent embolization procedure combines the opportunity to study novel concepts of stent or flow diverter based devices as well as the molecular aspects of healing.

  14. Emergency Endovascular Treatment of an Acute Traumatic Rupture of the Thoracic Aorta Complicated by a Distal Low-Flow Syndrome

    International Nuclear Information System (INIS)

    Bruninx, Guy; Wery, Didier; Dubois, Eric; El Nakadi, Badih; Dueren, Eric van; Verhelst, Guy; Delcour, Christian

    1999-01-01

    We report the case of a patient who suffered major trauma following a motorcycle accident that resulted in multiple fractures, bilateral hemopneumothorax, pulmonary contusions, and an isthmic rupture of the aorta with a pseudoaneurysm compressing the descending aorta. This compression was responsible for distal hypotension and low flow, leading to acute renal insufficiency and massive rhabdomyolysis. Due to the critical clinical status of the patient, which prevented any type of open thoracic surgery, endovascular treatment was performed. An initial stent-graft permitted alleviation of the compression and the re-establishment of normal hemodynamic conditions, but its low position did not allow sufficient coverage of the rupture. A second stent-graft permitted total exclusion of the pseudoaneurysm while preserving the patency of the left subclavian artery

  15. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  16. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  17. Comparison of long-term clinical outcome between patients with chronic versus acute type B aortic dissection treated by implantation of a stent graft: a single-center report

    Directory of Open Access Journals (Sweden)

    Chen SL

    2013-04-01

    Full Text Available Shao-Liang Chen, Jian-Cheng Zhu, Xiao-Bo Li, Fei Ye, Jun-Jie Zhang, Zhi-Zhong Liu, Nai-Liang Tian, Song Lin, Cheng-Yu Lv Nanjing First Hospital, Nanjing Medical University, Nanjing, People's Republic of China Background: Stent grafting for treatment of type B aortic dissection has been extensively used. However, the difference in the long-term clinical outcome between patients with chronic versus acute type B aortic dissection remains unknown. This study aimed to analyze the difference in long-term clinical outcome after endovascular repair for patients with chronic (93% complete false-lumen thrombosis. Untreated tear and type I endoleak were predictors of clinical events during follow-up. Conclusion: Comparable long-term clinical results were achieved in patients with chronic or acute type B aortic dissection after implantation of a stent graft. Keywords: aortic dissection, endovascular repair, procedure-related events, propensity score matching

  18. Learning curve for intracranial angioplasty and stenting in single center.

    Science.gov (United States)

    Cai, Qiankun; Li, Yongkun; Xu, Gelin; Sun, Wen; Xiong, Yunyun; Sun, Wenshan; Bao, Yuanfei; Huang, Xianjun; Zhang, Yao; Zhou, Lulu; Zhu, Wusheng; Liu, Xinfeng

    2014-01-01

    To identify the specific caseload to overcome learning curve effect based on data from consecutive patients treated with Intracranial Angioplasty and Stenting (IAS) in our center. The Stenting and Aggressive Medical Management for Preventing Recurrent Stroke and Intracranial Stenosis trial was prematurely terminated owing to the high rate of periprocedural complications in the endovascular arm. To date, there are no data available for determining the essential caseload sufficient to overcome the learning effect and perform IAS with an acceptable level of complications. Between March 2004 and May 2012, 188 consecutive patients with 194 lesions who underwent IAS were analyzed retrospectively. The outcome variables used to assess the learning curve were periprocedural complications (included transient ischemic attack, ischemic stroke, vessel rupture, cerebral hyperperfusion syndrome, and vessel perforation). Multivariable logistic regression analysis was employed to illustrate the existence of learning curve effect on IAS. A risk-adjusted cumulative sum chart was performed to identify the specific caseload to overcome learning curve effect. The overall rate of 30-days periprocedural complications was 12.4% (24/194). After adjusting for case-mix, multivariate logistic regression analysis showed that operator experience was an independent predictor for periprocedural complications. The learning curve of IAS to overcome complications in a risk-adjusted manner was 21 cases. Operator's level of experience significantly affected the outcome of IAS. Moreover, we observed that the amount of experience sufficient for performing IAS in our center was 21 cases. Copyright © 2013 Wiley Periodicals, Inc.

  19. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  20. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  1. Endovascular management of lap belt-related abdominal aortic injury in a 9-year-old child.

    Science.gov (United States)

    Papazoglou, Konstantinos O; Karkos, Christos D; Kalogirou, Thomas E; Giagtzidis, Ioakeim T

    2015-02-01

    Blunt abdominal aortic trauma is a rare occurrence in children with only a few patients having been reported in the literature. Most such cases have been described in the context of lap belt injuries. We report a 9-year-old boy who suffered lap belt trauma to the abdomen during a high-speed road traffic accident resulting to the well-recognized pattern of blunt abdominal injury, that is, the triad of intestinal perforation, fractures of the lumbar spine, and abdominal aortic injury. The latter presented with lower limb ischemia due to dissection of the infrarenal aorta and right common iliac artery. Revascularization was achieved by endovascular means using 2 self-expanding stents in the infrarenal aorta and the right common iliac artery. This case is one of the few reports of lap belt-related acute traumatic abdominal aortic dissection in a young child and highlights the feasibility of endovascular management in the pediatric population. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Percutaneous treatment of superior vena cava syndrome using metallic stents

    International Nuclear Information System (INIS)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma; Gamboa, Pablo; Tobio, Ricardo; Herrera, Marcos

    2003-01-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  3. Sex differences in the outcomes of stent implantation in mini-swine model.

    Science.gov (United States)

    Kunio, Mie; Wong, Gee; Markham, Peter M; Edelman, Elazer R

    2018-01-01

    Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.

  4. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Alzamora, M.G.; Klisch, J. [Section of Neuroradiology, Neurocenter, University of Freiburg (Germany); Rosahl, S.K.; Lehmberg, J. [Department of Neurosurgery, Neurocenter, University of Freiburg (Germany)

    2005-04-01

    The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel.

  5. Life-threatening bleeding from a vertebral artery pseudoaneurysm after anterior cervical spine approach: endovascular repair by a triple stent-in-stent method. Case report

    International Nuclear Information System (INIS)

    Alzamora, M.G.; Klisch, J.; Rosahl, S.K.; Lehmberg, J.

    2005-01-01

    The incidence of injury to the cervical vertebral artery during surgery for stenosis of the cervical neuroforamina is very low. We present a case in which bleeding during microforaminotomy at the level C6/7 occurred. The bleeding could be controlled intraoperatively. Two days later, a life-threatening cervical hematoma required urgent bedside evacuation. A false aneurysm of the left cervical vertebral artery was successfully occluded by a modified triple stent-in-stent technique, maintaining the flow in the vessel

  6. Valve-Like and Protruding Calcified Intimal Flap Complicating Common Iliac Arteries Kissing Stenting

    Directory of Open Access Journals (Sweden)

    George S. Georgiadis

    2015-01-01

    Full Text Available Endovascular therapy for iliac artery chronic total occlusions is nowadays associated with low rates of procedure-related complications and improved clinical outcomes, and it is predominantly used as first-line therapy prior to aortobifemoral bypass grafting. Herein, we describe the case of a patient presenting with an ischemic left foot digit ulcer and suffering complex aortoiliac lesions, who received common iliac arteries kissing stents, illustrating at final antegrade and retrograde angiograms the early recognition of a blood flow obstructing valve-like calcified intimal flap protruding through the stent struts, which was obstructing antegrade but not retrograde unilateral iliac arterial axis blood flow. The problem was resolved by reconstructing the aortic bifurcation at a more proximal level. Completion angiogram verified normal patency of aorta and iliac vessels. Additionally, a severe left femoral bifurcation stenosis was also corrected by endarterectomy-arterioplasty with a bovine patch. Postintervention ankle brachial pressure indices were significantly improved. At the 6-month and 2-year follow-up, normal peripheral pulses were still reported without intermittent claudication suggesting the durability of the procedure. Through stent-protruding calcified intimal flap, is a very rare, but existing source of antegrade blood flow obstruction after common iliac arteries kissing stents.

  7. Endovascular Repair of an Actively Hemorrhaging Stab Wound Injury to the Abdominal Aorta

    International Nuclear Information System (INIS)

    Hussain, Qasim; Maleux, Geert; Heye, Sam; Fourneau, Inge

    2008-01-01

    Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealed an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.

  8. Treatment of Visceral Aneurysm Using Multilayer Stent: Two-Year Follow-Up Results in Five Consecutive Patients

    Energy Technology Data Exchange (ETDEWEB)

    Balderi, Alberto, E-mail: balders@libero.it; Antonietti, Alberto, E-mail: antonietti.a@ospedale.cuneo.it; Pedrazzini, Fulvio, E-mail: pedrazzini.f@ospedale.cuneo.it; Sortino, Davide, E-mail: davide.sortino@hotmail.it; Vinay, Claudia, E-mail: claudia.vinay@gmail.com; Grosso, Maurizio, E-mail: grosso.m@ospedale.cuneo.it [AO Santa Croce e Carle Hospital, Department of Radiology (Italy)

    2013-10-15

    Purpose: The present study was performed to analyze the midterm results (five consecutive patients, 2-year follow-up) of the endovascular management of visceral artery aneurysms using the Cardiatis Multilayer Flow Modulator (CMFM) (Cardiatis, Isnes, Belgium), a self-expandable stent. Materials and Methods: From August 2009 to January 2011, we implanted five CMFMs in five patients (all men; mean age 73 years) to treat two common hepatic artery aneurysms, one celiac trunk aneurysm, one splenic artery aneurysm, and one superior mesenteric artery aneurysm (diameter 25-81 mm). The primary end point was technical success. The secondary end point was stent patency, absence of aneurysm rupture or reperfusion, and shrinking of the sac at 6-, 12-, and 24-month follow-up using computed tomography angiography. Follow-up ranged from 24 to 48 months (mean 31.2). Results: Technical success was achieved in all patients. Complete exclusion of the aneurysm with sac shrinking was achieved in two patients. Two stents became occluded at 6- and 24-month follow-up, respectively; both patients were asymptomatic and were not retreated. One patient developed sac reperfusion due to incomplete aneurysm exclusion. Conclusion: Long-term results in a wider population are needed to validate the effectiveness of the CMFM.

  9. Stent assisted coil embolization of a dissecting aneurysm of the vertebral artery: a case involving a patient with hypoplasia of the contralateral vertebral artery

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Jeong, Hae Woong; Cho, Jae Kwoeng; Park, Jeong Hoon; Koo, Yong Woon; Baik, Seung Kug

    2002-01-01

    A dissecting aneurysm of the vertebral artery may be treated conservatively, surgically, or using an endovascular approach. Proximal clipping, wrapping or trapping are surgical treatment methods, and endovascular treatment with coils and balloons is performed where a dissecting aneurysm is located near the midline or the appropriate surgical manipulation is difficult. As the contralateral vertebral artery of this patient was hypoplastic, the stent-assisted coil embolization technique was employed to preserve the ipsilateral vertebral artery. We describe a clinical case of dissecting aneurysm of the vertebral artery occurring in a patient in whom a hypoplastic contralateral vertebral artery was successfully treated

  10. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  11. Endovascular interventions for TASC II D femoropopliteal lesions.

    Science.gov (United States)

    Baril, Donald T; Chaer, Rabih A; Rhee, Robert Y; Makaroun, Michel S; Marone, Luke K

    2010-06-01

    Advances in endovascular techniques have provided new options in the treatment of complex infrainguinal occlusive lesions. The purpose of this study was to evaluate outcomes of endovascular interventions on TransAtlantic InterSociety (TASC) II D femoropopliteal occlusive disease. All patients undergoing endovascular interventions for femoropopliteal occlusive disease between July 2004 and July 2009 were reviewed. Patient demographics, pre- and postprocedure ankle-brachial indices (ABI) and anatomic factors were analyzed. Outcomes evaluated included primary patency, assisted-patency, secondary patency, predictors of restenosis, and wound healing. Five hundred eighty-five limbs were treated during the period reviewed. The study group included 79 TASC D limbs in 74 patients (mean age 76.5 +/- 11.9 years, male sex: 53%). Fifty-six limbs (71%) underwent treatment for critical limb ischemia, including 42 (53%) with tissue loss. Eleven patients (15%) had previous failed bypasses. Preoperative ABIs were unobtainable for 23 patients, while the remaining 56 had a mean baseline ABI of 0.54 +/- 0.28. There was one periprocedural mortality. Five patients (6.3%) had periprocedural complications. Mean increase in ABI postprocedure was 0.49 +/- 0.35. Follow-up was available for 74 limbs at a mean of 10.7 months (range, 1-35). There were 18 mortalities (24.3%) during the follow-up period. No patient required a major amputation during this follow-up period. Twenty-one limbs (26.6%) experienced restenosis and nine limbs (11.4%) experienced occlusion. Twenty-nine limbs underwent reintervention during the follow-up time, including nine which underwent multiple reinterventions. Primary, assisted-primary, and secondary patency rates at 12 and 24 months were 52.2%, 88.4%, 92.6% and 27.5%, 74.2%, and 88.9%, respectively. Predictors of restenosis/occlusion included hypercholesterolemia, the presence of a popliteal artery stent, and patients who were current or former smokers. Endovascular

  12. Carotid artery stenting: Rationale, technique, and current concepts

    International Nuclear Information System (INIS)

    Yilmaz, Hasan; Pereira, Vitor Mendes; Narata, Ana-Paula; Sztajzel, Roman; Lovblad, Karl-Olof

    2010-01-01

    Carotid stenosis is a major risk factor for stroke. With the aging of the general population and the availability of non-invasive vascular imaging studies, the diagnosis of a carotid plaque is commonly made in medical practice. Asymptomatic and symptomatic carotid stenoses need to be considered separately because their natural history is different. Two large randomized controlled trials (RCTs) showed the effectiveness of carotid endarterectomy (CEA) in preventing ipsilateral ischemic events in patients with symptomatic severe stenosis. The benefit of surgery is much less for moderate stenosis and harmful in patients with stenosis less than 50%. Surgery has a marginal benefit in patients with asymptomatic stenosis. Improvements in medical treatment must be taken into consideration when interpreting the results of these previous trials which compared surgery against medical treatment available at the time the trials were conducted. Carotid artery stenting (CAS) might avoid the risks associated with surgery, including cranial nerve palsy, myocardial infarction, or pulmonary embolism. Therefore and additionally to well-established indications of CAS, this endovascular approach might be a valid alternative particularly in patients at high surgical risk. However, trials of endovascular treatment of carotid stenosis have failed to provide enough evidence to justify routine CAS as an alternative to CEA in patients suitable for surgery. More data from ongoing randomized trials of CEA versus CAS will be soon available. These results will help determining the role of CAS in the management of patients with carotid artery stenosis.

  13. Functional outcome after primary endovascular therapy or IV thrombolysis alone for stroke. An observational, comparative effectiveness study.

    Science.gov (United States)

    Abilleira, Sònia; Ribera, Aida; Dávalos, Antonio; Ribó, Marc; Chamorro, Angel; Cardona, Pere; Molina, Carlos A; Martínez-Yélamos, Antonio; Urra, Xabier; Dorado, Laura; Roquer, Jaume; Martí-Fàbregas, Joan; Aja, Lucía; Tomasello, Alejandro; Castaño, Carlos; Blasco, Jordi; Cánovas, David; Castellanos, Mar; Krupinski, Jerzy; Guimaraens, Leopoldo; Perendreu, Joan; Ustrell, Xavier; Purroy, Francisco; Gómez-Choco, Manuel; Baiges, Joan Josep; Cocho, Dolores; Saura, Júlia; Gallofré, Miquel

    2014-01-01

    Among the acute ischemic stroke patients with large vessel occlusions and contraindications for the use of IV thrombolysis, mainly on oral anticoagulation or presenting too late, primary endovascular therapy is often performed as an alternative to the standard therapy even though evidence supporting the use of endovascular reperfusion therapies is not yet established. Using different statistical approaches, we compared the functional independence rates at 3 months among patients undergoing primary endovascular therapy and patients treated only with IV thrombolysis. We used data from a prospective, government-mandated and externally audited registry of reperfusion therapies for ischemic stroke (January 2011 to November 2012). Patients were selected if treated with either IV thrombolysis alone (n = 1,582) or primary endovascular thrombectomy (n = 250). A series of exclusions were made to homogenize the clinical characteristics among the two groups. We then carried out multivariate logistic regression and propensity score matching analyses on the final study sample (n = 1,179) to compare functional independence at 3 months, as measured by the modified Rankin scale scores 0-2, between the two groups. The unadjusted likelihood of good outcome was poorer among the endovascular group (OR: 0.69; 95% CI: 0.47-1.0). After adjustment, no differences by treatment modality were seen (OR: 1.51; 95% CI: 0.93-2.43 for primary endovascular therapy). Patients undergoing endovascular thrombectomy within 180-270 min (OR: 2.89; 95% CI: 1.17-7.15) and patients with severe strokes (OR: 1.84; 95% CI: 1.02-3.35) did better than their intravenous thrombolysis counterparts. The propensity score-matched analyses with and without adjustment by additional covariates showed that endovascular thrombectomy was as effective as intravenous thrombolysis alone in achieving functional independence (OR for unadjusted propensity score matched: 1.35; 95% CI: 0.9-2.02, OR for adjusted propensity score

  14. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  15. Unusual rapid evolution of type B aortic dissection in a marfan patient following heart transplantation: successful endovascular treatment.

    Science.gov (United States)

    Botta, L; Russo, V; Grigioni, F; Arpesella, G; Rocchi, G; Di Bartolomeo, R; Fattori, R

    2006-10-01

    A patient with Marfan syndrome with previous Bentall operation for mitral and tricuspid valve repair, required orthotopic cardiac transplantation for end stage cardiomyopathy. Postoperatively he suffered type-B aortic dissection, despite normal aortic diameters. Following sudden increase of aortic diameters, two years later, he underwent successful stent graft implantation. In patients with Marfan syndrome, post transplantation morbidity is high, with a 40% incidence of thoracic aortic dissection. This case highlights the potential of endovascular approach for treating post-transplantation aortic dissection.

  16. Transpedal approach for iliac artery stenting: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zachariah, Jips J., E-mail: jzachariah@chpnet.org [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Ratcliffe, Justin A.; Ruisi, Michael; Puma, Joseph [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Bertrand, Olivier [Quebec Heart and Lung Institute, Quebec (Canada); Kwan, Tak [Mount Sinai Beth Israel Hospital, New York, NY (Israel)

    2016-12-15

    Objective: To demonstrate the safety and feasibility of the transpedal approach as an alternate arterial access site for iliac artery intervention. Background: The common femoral artery is the traditional access site for the endovascular treatment of iliac artery stenoses. However, this approach is associated with complication rates as high as 2%, including retroperitoneal bleeding which carries high patient morbidity and mortality. Furthermore, the standard femoral approach is associated with longer recovery times and longer time to ambulation which are important considerations especially when performing procedures in an ambulatory setting. Methods: Twelve patients were prospectively followed after treatment for symptomatic iliac artery stenosis via transpedal access. Under ultrasound guidance, one of the pedal arteries was visualized and accessed, and stenting of the iliac arteries were performed as per protocol. The patient was monitored immediately post procedure and clinical follow up was performed at one week and one month later. Results: The average age of the patients was 71 years old. 58% were male. Most patients had Rutherford class III symptoms. Successful stent placement was achieved in all 12 patients via transpedal access. No conversion to femoral access was required. No complications immediately post procedure nor at any time period during follow up were noted. Lower extremity arterial duplex at one month showed patent stents and patent pedal access site vessels in all patients. Conclusion: Transpedal arterial access may be a safe and feasible approach for iliac artery stenting. Given the possible benefits of avoiding femoral artery access, larger studies should be conducted directly comparing the different approaches.

  17. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  18. Endovascular repair of an aorto-iliac aneurysm succeeded by kidney transplantation Tratamento endovascular de aneurisma aorto-ilíaco sucedido por transplante renal

    Directory of Open Access Journals (Sweden)

    Marcelo Bellini Dalio

    2010-09-01

    Full Text Available We present the case of aorto-iliac aneurysm in a patient with chronic renal failure requiring dialysis who were treated with an endovascular stent graft and, later on, submitted to kidney transplantation. A 53-year-old male with renal failure requiring dialysis presented with an asymptomatic abdominal aorto-iliac aneurysm measuring 5.0cm of diameter. He was treated with endovascular repair technique, being used an endoprosthesis Excluder®. After four months, he was successfully submitted to kidney transplantation (dead donor, with anastomosis of the graft renal artery in the external iliac artery distal to the endoprosthesis. The magnetic resonance imaging, carried out 30 days after the procedure, showed a good positioning of the endoprosthesis and adequate perfusion of the renal graft. In the follow-up, the patient presented improvement of nitrogenous waste, good positioning of the endoprosthesis without migration or endoleak. The endovascular repair of aorto-iliac aneurysm in a patient with end-stage renal failure under hemodialysis treatment showed to be feasible, safe and efficient, as it did not prevent the success of the posterior kidney transplantation.Apresentamos o caso de aneurisma aortoilíaco em um paciente com insuficiência renal crônica dialítica tratado com uma endoprótese vascular, sendo, após, submetido a transplante renal. Um homem de 53 anos com insuficiência renal dialítica apresentava um aneurisma abdominal aortoilíaco assintomático com 5,0cm de diâmetro. Foi tratado com técnica endovascular com uma endoprótese Excluderâ. Após quatro meses, foi submetido a transplante renal (doador cadáver com sucesso, com anastomose da artéria renal do enxerto na artéria ilíaca externa distal à endoprótese. A ressonância magnética 30 dias após o procedimento mostrou a endoprótese bem posicionada e o enxerto renal bem perfundido. No seguimento, o paciente evoluiu com melhora das escórias nitrogenadas, bom

  19. Heparin surface stent-graft for the treatment of a carotid pseudoaneurysm.

    Science.gov (United States)

    Tsolaki, Elpiniki; Elpiniki, Tsolaki; Salviato, Elisabetta; Rocca, Tiberio; Braccini, Lucia; Galeotti, Roberto; Mascoli, Francesco

    2010-10-01

    Carotid pseudoaneurysms are a rare consequence of carotid surgery, trauma, and infection. Historically, carotid aneurysms and pseudoaneurysms were treated surgically. However, endovascular techniques have recently become a valid alternative for the treatment of carotid pseudoaneurysms. The case of a 57-year-old male patient with a pseudoaneurysm of the right internal carotid artery is described. The patient came to our unit with a painless and pulsatile mass in the neck, which was growing slowly. Five years earlier, he had undergone surgery on a saccular aneurysm located on the distal extracranial segment of the right internal carotid artery. The pseudoaneurysm was successfully treated with a heparin surface Viabahn stent-graft system (Gore AL, Flagstaff, AZ). Heparin surface stent-grafts can be used for the treatment of carotid lesions and may offer protection against intimal hyperplasia and thrombosis. Further studies are needed to evaluate the long-term results. Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  20. The fluoro-less and contrast-less peripheral endovascular intervention: a concept for the future today

    International Nuclear Information System (INIS)

    Ephrem, Georges; Lau, Joe F.; Meraj, Perwaiz M.

    2015-01-01

    Introduction: Percutaneous endovascular revascularization requires fluoroscopic guidance and radiopaque contrast use. This approach becomes problematic, especially in patients with advanced renal disease or allergies to iodinated contrast medium. The direct (exposure) and indirect (lead garment) burden of radiation affects patients and operators alike. Purpose: We propose a completely contrast-free, fluoroscopy-free approach to endovascular diagnostic arterial imaging and percutaneous intervention using available technologies, and outline a timeframe for its implementation. Project Description/Methodology: Ultrasound imaging of the leg creates a roadmap of the vessel and identifies the lesion of interest. Device-based sensors using a low-powered electromagnetic field allow for wiring of the vessel. This is followed by the use of intravascular ultrasonography and near infrared spectroscopy to characterize the lesion dimensions and composition. After completion of the diagnostic phase of the process, the interventional portion with deployment of an angioplasty balloon and/or stent is performed using the electromagnetic field-guided sensors. Feasibility: The project uses already available technologies. Benefits/Anticipated Outcomes: This project demonstrates the real potential of performing endovascular peripheral intervention without fluoroscopy or contrast in a practical, user-friendly way with the currently available technology. The prospects in renal function preservation and radiation avoidance for both patients and operators are extremely attractive. - Highlights: • We propose an endovascular peripheral intervention without fluoroscopy or contrast. • It is based on ultrasound, electromagnetic sensors, and near infrared spectroscopy. • The method is practical and uses available technology. • The prospects in renal function preservation and radiation avoidance are excellent

  1. The fluoro-less and contrast-less peripheral endovascular intervention: a concept for the future today

    Energy Technology Data Exchange (ETDEWEB)

    Ephrem, Georges, E-mail: g.ephrem@gmail.com; Lau, Joe F.; Meraj, Perwaiz M.

    2015-07-15

    Introduction: Percutaneous endovascular revascularization requires fluoroscopic guidance and radiopaque contrast use. This approach becomes problematic, especially in patients with advanced renal disease or allergies to iodinated contrast medium. The direct (exposure) and indirect (lead garment) burden of radiation affects patients and operators alike. Purpose: We propose a completely contrast-free, fluoroscopy-free approach to endovascular diagnostic arterial imaging and percutaneous intervention using available technologies, and outline a timeframe for its implementation. Project Description/Methodology: Ultrasound imaging of the leg creates a roadmap of the vessel and identifies the lesion of interest. Device-based sensors using a low-powered electromagnetic field allow for wiring of the vessel. This is followed by the use of intravascular ultrasonography and near infrared spectroscopy to characterize the lesion dimensions and composition. After completion of the diagnostic phase of the process, the interventional portion with deployment of an angioplasty balloon and/or stent is performed using the electromagnetic field-guided sensors. Feasibility: The project uses already available technologies. Benefits/Anticipated Outcomes: This project demonstrates the real potential of performing endovascular peripheral intervention without fluoroscopy or contrast in a practical, user-friendly way with the currently available technology. The prospects in renal function preservation and radiation avoidance for both patients and operators are extremely attractive. - Highlights: • We propose an endovascular peripheral intervention without fluoroscopy or contrast. • It is based on ultrasound, electromagnetic sensors, and near infrared spectroscopy. • The method is practical and uses available technology. • The prospects in renal function preservation and radiation avoidance are excellent.

  2. Time-Resolved 3D Contrast-Enhanced MRA on 3.0T: a Non-Invasive Follow-Up Technique after Stent-Assisted Coil Embolization of the Intracranial Aneurysm

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Roh, Hong Gee; Moon, Won Jin; Kim, Na Ra; Moon, Sung Gyu; Kang, Chung Hwan; Chun, Young Il; Kang, Hyun Seung

    2011-01-01

    To evaluate the usefulness of time-resolved contrast enhanced magnetic resonance angiography (4D MRA) after stent-assisted coil embolization by comparing it with time of flight (TOF)-MRA. TOF-MRA and 4D MRA were obtained by 3T MRI in 26 patients treated with stent-assisted coil embolization (Enterprise:Neuroform = 7:19). The qualities of the MRA were rated on a graded scale of 0 to 4. We classified completeness of endovascular treatment into three categories. The degree of quality of visualization of the stented artery was compared between TOF and 4D MRA by the Wilcoxon signed rank test. We used the Mann-Whitney U test for comparing the quality of the visualization of the stented artery according to the stent type in each MRA method. The quality in terms of the visualization of the stented arteries in 4D MRA was significantly superior to that in 3D TOF-MRA, regardless of type of the stent (p < 0.001). The quality of the arteries which were stented with Neuroform was superior to that of the arteries stented with Enterprise in 3D TOF (p < 0.001) and 4D MRA (p = 0.008), respectively. 4D MRA provides a higher quality view of the stented parent arteries when compared with TOF.

  3. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution

    Science.gov (United States)

    Coté, Gregory A.; Slivka, Adam; Tarnasky, Paul; Mullady, Daniel K.; Elmunzer, B. Joseph; Elta, Grace; Fogel, Evan; Lehman, Glen; McHenry, Lee; Romagnuolo, Joseph; Menon, Shyam; Siddiqui, Uzma D.; Watkins, James; Lynch, Sheryl; Denski, Cheryl; Xu, Huiping; Sherman, Stuart

    2017-01-01

    IMPORTANCE Endoscopic placement of multiple plastic stents in parallel is the first-line treatment for most benign biliary strictures; it is possible that fully covered, self-expandable metallic stents (cSEMS) may require fewer endoscopic retrograde cholangiopancreatography procedures (ERCPs) to achieve resolution. OBJECTIVE To assess whether use of cSEMS is noninferior to plastic stents with respect to stricture resolution. DESIGN, SETTING, AND PARTICIPANTS Multicenter (8 endoscopic referral centers), open-label, parallel, randomized clinical trial involving patients with treatment-naive, benign biliary strictures (N = 112) due to orthotopic liver transplant (n = 73), chronic pancreatitis (n = 35), or postoperative injury (n = 4), who were enrolled between April 2011 and September 2014 (with follow-up ending October 2015). Patients with a bile duct diameter less than 6 mm and those with an intact gallbladder in whom the cystic duct would be overlapped by a cSEMS were excluded. INTERVENTIONS Patients (N = 112) were randomized to receive multiple plastic stents or a single cSEMS, stratified by stricture etiology and with endoscopic reassessment for resolution every 3 months (plastic stents) or every 6 months (cSEMS). Patients were followed up for 12 months after stricture resolution to assess for recurrence. MAIN OUTCOMES AND MEASURES Primary outcome was stricture resolution after no more than 12 months of endoscopic therapy. The sample size was estimated based on the noninferiority of cSEMS to plastic stents, with a noninferiority margin of −15%. RESULTS There were 55 patients in the plastic stent group (mean [SD] age, 57 [11] years; 17 women [31%]) and 57 patients in the cSEMS group (mean [SD] age, 55 [10] years; 19 women [33%]). Compared with plastic stents (41/48, 85.4%), the cSEMS resolution rate was 50 of 54 patients (92.6%), with a rate difference of 7.2% (1-sided 95% CI, −3.0% to ∞; P stents was rejected. The mean number of ERCPs to achieve resolution

  4. Endovascular repair of posttraumatic multiple femoral-femoral and popliteal-popliteal arteriovenous fistula with Viabahn and excluder stent graft

    Directory of Open Access Journals (Sweden)

    Šarac Momir

    2011-01-01

    . Also, numerous metallic balls - grains of shotgun were present. After the preoperative preparation under local infiltrative anesthesia, transfemoral endovascular reconstruction was done of the surface femoral and popliteal artery by the use of stent grafts Viabahn 6 × 50 mm and excluder PXL 161 007. Within the immediate postoperative course a significant reduction of the leg edema and disappearance of thrill occurred, and, latter, healing of ulceration, and disappearance of signs of the foot ischemia. Also, patient's both cardiac and breathing functions became normal. Conclusion. In patients with chronic traumatic AV fistulas in the femoropopliteal region, especially with multiple fistulas, the gold standard is their endovascular reconstruction which, although being minimally traumatic and invasive, offers a complete reconstruction besides keeping integrity of both distal and proximal circulation in the leg.

  5. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Efectos biológicos de los stents medicados en la circulación coronaria Biological effects of drug-eluting stents in the coronary circulation

    Directory of Open Access Journals (Sweden)

    Darío Echeverri

    2010-04-01

    Full Text Available Los stents medicados ofrecen la mejor alternativa disponible no quirúrgica para el tratamiento de la enfermedad coronaria gracias a su demostrada eficacia. Sin embargo, estos excelentes resultados han sido opacados en términos de seguridad, principalmente por la presencia de trombosis de stents de manera tardía o muy tardía. La comprensión de los efectos biológicos que ejercen a nivel de la arteria coronaria luego de su implante, se debe al efecto de la plataforma utilizada, el polímero y la droga que liberan. Los trastornos de reparación vascular inducidos favorecen la trombosis de stents y sus consecuencias clínicas. Se hace una revisión de los diferentes efectos biológicos de los stents medicados en las arterias coronarias, que permite comprender como han surgido rápidamente nuevas versiones en materiales, diseños, polímeros y medicamentos que reducen los efectos adversos a nivel coronario, mejorando su eficacia y seguridad.Drug-eluting stents offer the best available non-surgical alternative for the treatment of coronary disease, thanks to its demonstrated efficacy. However, in terms of security, these excellent results have been overshadowed by the late or very late appearance of stent thromboses.The biological effects they have in the coronary artery after its implantation are due to the effect of the platform used, the polymer and the medication released. The vascular healing disorders induced by drug-eluting stents favor stent thrombosis and its clinical consequences. This is a review of the different biological effects of drug-eluting stents in coronary arteries that allows to understand how the rapid onset of new versions of materials, designs, polymers and medications diminish adverse coronary effects and improve its efficacy and safety.

  7. Patient effective dose from endovascular brachytherapy with {sup 192}Ir Sources

    Energy Technology Data Exchange (ETDEWEB)

    Perna, L.; Bianchi, C.; Novario, R.; Nicolini, G.; Tanzi, F.; Conte, L

    2002-07-01

    The growing use of endovascular brachytherapy has been accompanied by the publication of a large number of studies in several fields, but few studies on patient dose have been found in the literature. Moreover, these studies were carried out on the basis of Monte Carlo simulation. The aim of the present study was to estimate the effective dose to the patient undergoing endovascular brachytherapy treatment with {sup 192}Ir sources, by means of experimental measurements. Two standard treatments were taken into account: an endovascular brachytherapy of the coronary artery corresponding to the activity x time product of 184 GBq.min and an endovascular brachytherapy of the renal artery (898 GBq.min). Experimental assessment was accomplished by thermoluminescence dosemeters positioned in more than 300 measurement points in a properly adapted Rando phantom. A method has been developed to estimate the mean organ doses for all tissues and organs concerned in order to calculate the effective dose associated with intravascular brachytherapy. The normalised organ doses resulting from coronary treatment were 2.4x10{sup -2} mSv.GBq{sup -1}.min{sup -1} for lung, 0.9x10{sup -2} mSv.GBq{sup -1}.min{sup -1} for oesophagus and 0.48x10{sup -2} mSv.GBq{sup -1}.min{sup -1} for bone marrow. During brachytherapy of the renal artery, the corresponding normalised doses were 4.2x10{sup -2} mSv.GBq{sup -1}.min{sup -1} for colon, 7.8x10{sup -2} mSv.GBq{sup -1}.min{sup -1} for stomach and 1.7x10{sup -2} mSv.GBq{sup -1}.min{sup -1} for liver. Coronary treatment involved an effective dose of 0.046 mSv.GBq{sup -1}.min{sup -1}, whereas the treatment of the renal artery resulted in an effective dose of 0.15 mSv.GBq{sup -1}.min{sup -1}; there were many similarities with data from former studies. Based on these results it can be concluded that the dose level of patients exposed during brachytherapy treatment is low. (author)

  8. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  9. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention.

    Science.gov (United States)

    Baschet, Louise; Bourguignon, Sandrine; Marque, Sébastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117 762 patient-years with 76 randomised trials. The main effectiveness criterion was major cardiac event-free survival. Effectiveness and costs were modelled over a 5-year horizon using a three-state Markov model. Incremental cost-effectiveness ratios and a cost-effectiveness acceptability curve were calculated for a range of thresholds for willingness to pay per year without major cardiac event gain. Deterministic and probabilistic sensitivity analyses were performed. Base case results demonstrated that DES are dominant over BMS, with an increase in event-free survival and a cost-reduction of €184, primarily due to a diminution of second revascularisations, and an absence of myocardial infarction and stent thrombosis. These results are robust for uncertainty on one-way deterministic and probabilistic sensitivity analyses. Using a cost-effectiveness threshold of €7000 per major cardiac event-free year gained, DES has a >95% probability of being cost-effective versus BMS. Following DES price decrease, new-generation DES development and taking into account recent meta-analyses results, the DES can now be considered cost-effective regardless of selective indication in France, according to European recommendations.

  10. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  11. [Value of fractional flow reserve measurement in endovascular therapy for patients with Stanford B type aortic dissection complicated with renal blood flow injury].

    Science.gov (United States)

    Guo, Xi; Li, Peng; Liu, Guangrui; Huang, Xiaoyong; Yong, Qiang; Wang, Guoqin; Huang, Lianjun

    2015-10-01

    To analyze the value of fractional flow reserve (FFR) measurement on endovascular therapy for patients with renal artery stenosis. Clinical data of 12 patients with Stanford B type aortic dissection complicated with renal blood flow injury in Anzhen hospital hospitalized from May 2013 to February 2014 were retrospectively analyzed. Renal artery angiography was performed and fractional flow reserve (FFR) was measured before Thoracic endovascular aortic repair. After operation, renal artery FFR was measured again, and renal artery stenting was performed in patients with FFR ≤ 0.90 or average pressure difference between proximal and distal of renal artery > 20 mmHg (1 mmHg = 0.133 kPa) and not applied for patients with FFR > 0.90.The patients were then subsequently followed up clinically. Kidney function were measured after 1 month, and contrast-enhanced ultrasonography data were obtained at 1 and 3 months later, respectively. The FFR of 1 patient was 0.90, while the FFR of other patients were less than 0.90 before thoracic endovascular aortic repair. After the procedure,the angiography showed that the blood flow of renal artery in 8 patients were fluency, and the FFR index was over 0.90. There were 4 patients with FFR less than 0.90. After renal artery stenting, the FFR of these 4 patients were all above 0.90. Compared with pre-procedure, blood urea nitrogen ((8.84 ± 3.99) mmol/L vs. (5.18 ± 1.69) mmol/L, P = 0.011) and uric acid ((359.3 ± 77.3) µmol/L vs. (276.9 ± 108.3) µmol/L, P = 0.008) decreased significantly after 1 month, and there was no significant difference in serum creatinine (P = 0.760). Contrast-enhanced ultrasonography results showed that blood flow of renal artery were fluency after 1 month and 3 months. In patients with aortic dissection complicating renal blood flow injury, the FFR measurement is meaningful in evaluating the blood flow status of target organs and guide the endovascular revascularization.

  12. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  13. Endovascular Therapy of Ruptured Abdominal Aortic Aneurysm: Mid- and Long-Term Results

    International Nuclear Information System (INIS)

    Kubin, Klaus; Sodeck, Gottfried H.; Teufelsbauer, H.; Nowatschka, Bernd; Kretschmer, Georg; Lammer, Johannes; Schoder, Maria

    2008-01-01

    As an alternative to open aneurysm repair, emergency endovascular aortic repair (EVAR) has emerged as a promising technique for ruptured abdominal aortic aneurysm (rAAA) within the last decade. The aim of this retrospective study is to present early and late outcomes of patients treated with EVAR for rAAA. Twenty-two patients (5 women, 17 men; mean age, 74 years) underwent EVAR for rAAA between November 2000 and April 2006. Diagnostic multislice computed tomography angiography was performed prior to stent-graft repair to evaluate anatomical characteristics and for follow-up examinations. Periprocedural patient characteristics and technical settings were evaluated. Mortality rates, hospital stay, and early and late complications, within a mean follow-up time of 744 ± 480 days, were also assessed. Eight of 22 patients were hemodynamically unstable at admission. Stent-graft insertion was successful in all patients. The total early complication rate was 54%, resulting in a 30-day mortality rate of 23%. The median intensive care unit stay was 2 days (range, 2-48 days), and the median hospital stay was 16 days (range, 9-210 days). During the follow-up period, three patients suffered from stent-graft-related complications. The overall mortality rate in our study group was 36%. EVAR is an acceptable, minimally invasive treatment option in patients with acute rAAA, independent of the patient's general condition. Short- and long-term outcomes are definitely comparable to those with open surgical repair procedures

  14. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  15. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  16. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent.

    Science.gov (United States)

    Park, Jin Myung; Lee, Sang Hyub; Chung, Kwang Hyun; Jang, Dong Kee; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Min; Paik, Woo Hyun

    2016-12-01

    Bilateral stent-in-stent (SIS) self-expandable metal stent placement is technically challenging for palliation of unresectable malignant hilar obstruction. In the SIS technique, the uniform large cell type biliary stent facilitates contralateral stent deployment through the mesh of the first metallic stent. This study aimed to assess the technical success and clinical effectiveness of this technique with a uniform large cell type biliary stent. Thirty-one patients who underwent bilateral SIS placement using a large cell type stent were reviewed retrospectively. All patients showed malignant hilar obstruction (Bismuth types II, III, IV) with different etiologies. Sixteen (51.6%) patients were male. The mean age of the patients was 67.0+/-14.0 years. Most patients were diagnosed as having hilar cholangiocarcinoma (58.1%) and gallbladder cancer (29.0%). Technical success rate was 83.9%. Success was achieved more frequently in patients without masses obstructing the biliary confluence (MOC) than those with MOC (95.2% vs 60.0%, P=0.03). Functional success rate was 77.4%. Complications occurred in 29.0% of the patients. These tended to occur more frequently in patients with MOC (50.0% vs 19.0%, P=0.11). Median time to recurrent biliary obstruction was 188 days and median survival was 175 days. The large cell type stent can be used efficiently for bilateral SIS placement in malignant hilar obstruction. However, the risk of technical failure increases in patients with MOC, and caution is needed to prevent complications for these patients.

  17. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  18. Endovascular management of pancreatitis-related pseudoaneurysms: A review of techniques.

    Directory of Open Access Journals (Sweden)

    Bartosz Zabicki

    Full Text Available To present the various techniques used in the management of pancreatitis-related pseudoaneurysms of visceral vessels.The retrospective clinical study was carried out at the Department of Diagnostic and Interventional Radiology at Poznan University of Medical Sciences from 2011 to 2016. The fifteen patients included in the study were diagnosed with pseudoaneurysms of visceral arteries, as a complication of chronic pancreatitis. The diagnosis was made using contrast-enhanced computed tomography, followed by angiography. On admission, all patients were symptomatic, with varying degrees of abdominal pain. One patient was haemodynamically unstable. Treatments with endovascular techniques were analysed, along with their efficacy and outcomes. Coil embolisation was performed in 5 patients. Stent graft was used in 1 patient. Liquid embolic agents were used in 7 cases, of which 5 patients were treated with thrombin injection and 2 with Squid. A combination of techniques was used in 2 patients.The most common artery affected by pseudoaneurysm formation was the splenic artery (7/15; 46.7%, and the size of the pseudoaneurysms ranged from 27 mm to 85 mm. Primary technical success was achieved in 14 out of 15 patients (93.3%. One patient required reintervention. Two patients required splenectomy after embolisation due to splenic ischemia. No recanalisation was present at the follow-up computed tomography performed after 1 to 3 weeks, and no mortality was observed within 30 days.Vascular complications of pancreatitis require accurate diagnosis and immediate treatment. Endovascular intervention is highly effective and is the preferred treatment option. The technique used is determined based on vascular anatomy and the patient's haemodynamic status.

  19. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  20. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    Science.gov (United States)

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.