WorldWideScience

Sample records for effective dose evaluation

  1. Evaluation of effective dose and excess lifetime cancer risk from ...

    African Journals Online (AJOL)

    Evaluation of effective dose and excess lifetime cancer risk from indoor and outdoor gamma dose rate of university of Port Harcourt Teaching Hospital, Rivers State. ... Therefore, the management of University of Port Harcourt teaching hospital ...

  2. Evaluation of effective dose equivalent from environmental gamma rays

    International Nuclear Information System (INIS)

    Saito, K.; Tsutsumi, M.; Moriuchi, S.; Petoussi, N.; Zankl, M.; Veit, R.; Jacob, P.; Drexler, G.

    1991-01-01

    Organ doses and effective dose equivalents for environmental gamma rays were calculated using human phantoms and Monte Carlo methods accounting rigorously the environmental gamma ray fields. It was suggested that body weight is the dominant factor to determine organ doses. The weight function expressing organ doses was introduced. Using this function, the variation in organ doses due to several physical factors were investigated. A detector having gamma-ray response similar to that of human bodies has been developed using a NaI(Tl) scintillator. (author)

  3. Mathematical model for evaluation of dose-rate effect on biological responses to low dose γ-radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Kawakami, Y.; Magae, J.

    2003-01-01

    Full text: To evaluate quantitative dose-response relationship on the biological response to radiation, it is necessary to consider a model including cumulative dose, dose-rate and irradiation time. In this study, we measured micronucleus formation and [ 3 H] thymidine uptake in human cells as indices of biological response to gamma radiation, and analyzed mathematically and statistically the data for quantitative evaluation of radiation risk at low dose/low dose-rate. Effective dose (ED x ) was mathematically estimated by fitting a general function of logistic model to the dose-response relationship. Assuming that biological response depends on not only cumulative dose but also dose-rate and irradiation time, a multiple logistic function was applied to express the relationship of the three variables. Moreover, to estimate the effect of radiation at very low dose, we proposed a modified exponential model. From the results of fitting curves to the inhibition of [ 3 H] thymidine uptake and micronucleus formation, it was obvious that ED 50 in proportion of inhibition of [ 3 H] thymidine uptake increased with longer irradiation time. As for the micronuclei, ED 30 also increased with longer irradiation times. These results suggest that the biological response depends on not only total dose but also irradiation time. The estimated response surface using the three variables showed that the biological response declined sharply when the dose-rate was less than 0.01 Gy/h. These results suggest that the response does not depend on total cumulative dose at very low dose-rates. Further, to investigate the effect of dose-rate within a wider range, we analyzed the relationship between ED x and dose-rate. Fitted curves indicated that ED x increased sharply when dose-rate was less than 10 -2 Gy/h. The increase of ED x signifies the decline of the response or the risk and suggests that the risk approaches to 0 at infinitely low dose-rate

  4. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    International Nuclear Information System (INIS)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in μSv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  5. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  6. Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.N. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Division of Health Physics, Institute of Nuclear Energy Research, No. 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Huang, C.K. [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Tsai, W.C. [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Liu, Y.H. [Nuclear Science and Technol. Develop. Center, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China); Jiang, S.H., E-mail: shjiang@mx.nthu.edu.tw [Department of Engineering and System Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)] [Institute of Nuclear Engineering and Science, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan (China)

    2011-12-15

    This paper aims to evaluate the effective dose as well as equivalent doses of several organs of an adult hermaphrodite mathematical phantom according to the definition of ICRP Publication 60 for BNCT treatments of brain tumors in the epithermal neutron beam at THOR. The MCNP5 Monte Carlo code was used for the calculation of the average absorbed dose of each organ. The effective doses for a typical brain tumor treatment with a tumor treatment dose of 20 Gy-eq were evaluated to be 0.59 and 0.35 Sv for the LLAT and TOP irradiation geometries, respectively. In addition to the stochastic effect, it was found that it is also likely to produce deterministic effects, such as cataracts and depression of haematopoiesis.

  7. A prospective evaluation of hippocampal radiation dose volume effects and memory deficits following cranial irradiation.

    Science.gov (United States)

    Ma, Ting Martin; Grimm, Jimm; McIntyre, Riley; Anderson-Keightly, Heather; Kleinberg, Lawrence R; Hales, Russell K; Moore, Joseph; Vannorsdall, Tracy; Redmond, Kristin J

    2017-11-01

    To prospectively evaluate hippocampal radiation dose volume effects and memory decline following cranial irradiation. Effects of hippocampal radiation over a wide range of doses were investigated by combining data from three prospective studies. In one, adults with small cell lung cancer received hippocampal-avoidance prophylactic cranial irradiation. In the other two, adults with glioblastoma multiforme received neural progenitor cell sparing radiation or no sparing with extra dose delivered to subventricular zone. Memory was measured by the Hopkins Verbal Learning Test-Revised Delayed Recall (HVLT-R DR) at 6 months after radiation. Dose-volume histograms were generated and dose-response data were fitted to a nonlinear model. Of 60 patients enrolled, 30 were analyzable based on HVLT-R DR testing completion status, baseline HVLT-R DR and intracranial metastasis/recurrence or prior hippocampal resection status. We observed a dose-response of radiation to the hippocampus with regard to decline in HVLT-R DR. D50% of the bilateral hippocampi of 22.1 Gy is associated with 20% risk of decline. This prospective study demonstrates an association between hippocampal dose volume effects and memory decline measured by HVLT-R DR over a wide dose range. These data support a potential benefit of hippocampal sparing and encourage continued trial enrollment. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Compendium of cost-effectiveness evaluations of modifications for dose reduction at nuclear power plants

    International Nuclear Information System (INIS)

    Baum, J.W.; Matthews, G.R.

    1985-12-01

    This report summarizes available information on cost effectiveness of engineering modifications potentially valuable for dose reduction at nuclear power plants. Data were gathered from several US utilities, published literature, equipment and service suppliers, and recent technical meetings. Five simplified econometric models were employed to evaluate data and arrive at a value for cost effectiveness expressed in either (a) dollars/rem, or (b) total dollar savings calculated using a nominal value of $1000/rem. Models employed were: a basic model with no consideration given to the time value of money; two models in which discounting was used to evaluate costs and savings in terms of present values; and two models in which income taxes and revenue requirements were considered. Results from different models varied by as much as a factor of 10, and were generally lowest for the basic model and highest for the before-tax revenue requirements model. Results for 151 evaluations employing different assumptions concerning number of plants per site and outage impacts were tabulated in order of decreasing cost effectiveness. Twenty-five evaluations were identified as exceptionally cost effective since both costs and dose were saved. Forty evaluations indicated highly cost-effective changes based on costs below $1000/rem saved using results of the present-worth model that included discounting of future dose savings

  9. Evaluation of effective dose from CT scans for overweight and obese adult patients using the VirtualDose software

    International Nuclear Information System (INIS)

    Liang, Baohui; Gao, Yiming; Chen, Zhi; Xu, X. George

    2017-01-01

    This paper evaluates effective dose (ED) of overweight and obese patients who undergo body computed tomography (CT) examinations. ED calculations were based on tissue weight factors in the International Commission on Radiological Protection Publication 103 (ICRP 103). ED per unit dose length product (DLP) are reported as a function of the tube voltage, body mass index (BMI) of patient. The VirtualDose software was used to calculate ED for male and female obese phantoms representing normal weight, overweight, obese 1, obese 2 and obese 3 patients. Five anatomic regions (chest, abdomen, pelvis, abdomen/pelvis and chest/abdomen/pelvis) were investigated for each phantom. The conversion factors were computed from the DLP, and then compared with data previously reported by other groups. It was observed that tube voltage and BMI are the major factors that influence conversion factors of obese patients, and that ED computed using ICRP 103 tissue weight factors were 24% higher for a CT chest examination and 21% lower for a CT pelvis examination than the ED using ICRP 60 factors. For body CT scans, increasing the tube voltage from 80 to 140 kVp would increase the conversion factors by as much as 19-54% depending on the patient's BMI. Conversion factor of female patients was ∼7% higher than the factors of male patients. DLP and conversion factors were used to estimate ED, where conversion factors depended on tube voltage, sex, BMI and tissue weight factors. With increasing number of obese individuals, using size-dependence conversion factors will improve accuracy, in estimating patient radiation dose. (authors)

  10. Evaluation of low dose ionizing radiation effect on some blood components in animal model

    OpenAIRE

    El-Shanshoury, H.; El-Shanshoury, G.; Abaza, A.

    2016-01-01

    Exposure to ionizing radiation is known to have lethal effects in blood cells. It is predicted that an individual may spend days, weeks or even months in a radiation field without becoming alarmed. The study aimed to discuss the evaluation of low dose ionizing radiation (IR) effect on some blood components in animal model. Hematological parameters were determined for 110 animal rats (divided into 8 groups) pre- and post-irradiation. An attempt to explain the blood changes resulting from both ...

  11. Evaluation of effective dose in an anthropomorphic phantom in radiological emergencies situations

    International Nuclear Information System (INIS)

    Silva, Livia K. da; Ribeiro, Rosane M.; Santos, Denison de S.

    2013-01-01

    This work aims to implement the code of Monte Carlo Geant4 in a male and female phantom, ADAM and EVA, to be able to evaluate the dose in individuals who have been exposed externally to ionizing radiation sources so that in the future be made a review within the limits of validity of the terms contained in TECDOC-1162, published by the International Atomic Energy Agency (IAEA), which recommends formulas for the effective dose assessment in individuals who have been exposed to external radiation sources in various geometric configurations and for various radionuclides

  12. Evolution of radon dose evaluation

    Directory of Open Access Journals (Sweden)

    Fujimoto Kenzo

    2004-01-01

    Full Text Available The historical change of radon dose evaluation is reviewed based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR reports. Since 1955, radon has been recognized as one of the important sources of exposure of the general public. However, it was not really understood that radon is the largest dose contributor until 1977 when a new concept of effective dose equivalent was introduced by International Commission on Radiological Protection. In 1982, the dose concept was also adapted by UNSCEAR and evaluated per caput dose from natural radiation. Many researches have been carried out since then. However, lots of questions have remained open in radon problems, such as the radiation weighting factor of 20 for alpha rays and the large discrepancy of risk estimation among dosimetric and epidemiological approaches.

  13. Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose

    Science.gov (United States)

    Rabi, R.; Oufni, L.

    2018-04-01

    The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.

  14. Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms

    International Nuclear Information System (INIS)

    Lee, Hyun Cheol; Yoo, Do Hyeon; Testa, Mauro; Shin, Wook-Geun; Choi, Hyun Joon; Ha, Wi-Ho; Yoo, Jaeryong; Yoon, Seokwon; Min, Chul Hee

    2016-01-01

    The aim of this study is to evaluate the potential hazard of naturally occurring radioactive material (NORM) added consumer products. Using the Monte Carlo method, the radioactive products were simulated with ICRP reference phantom and the organ doses were calculated with the usage scenario. Finally, the annual effective doses were evaluated as lower than the public dose limit of 1 mSv y"−"1 for 44 products. It was demonstrated that NORM-added consumer products could be quantitatively assessed for the safety regulation. - Highlights: • Consumer products considered that NORM would be included should be regulated. • 44 products were collected and its gamma activities were measured with HPGe detector. • Through Monte Carlo simulation, organ equivalent doses and effective doses on human phantom were calculated. • All annual effective doses for the products were evaluated as lower than dose limit for the public.

  15. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom

    International Nuclear Information System (INIS)

    Hashim, S.; Karim, M.K.A.; Bakar, K.A.; Sabarudin, A.; Chin, A.W; Saripan, M.I.; Bradley, D.A.

    2016-01-01

    The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, ~8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose. - Highlights: • Using TLD-100 dosimeters and a RANDO phantom 5 CT thorax protocol organ doses were assessed. • The specific k coefficient for effective dose estimation of protocols differed with approach. • Organ dose was observed to decrease in the order: thyroid>skin>lung>liver>breast. • E103 k factors were constant for all protocols, lower by ~8% compared to the universal k factor.

  16. Evaluation for committed effective dose due to dietary foods by the intake for Japanese adults

    International Nuclear Information System (INIS)

    Ota, Tomoko; Sanada, Tetsuya; Kashiwara, Yoko; Morimoto, Takao; Sato, Kaneaki

    2009-01-01

    Radioactivity levels in 137 foods commonly consumed daily in Japan were evaluated to determine the committed effective dose in the Japanese adults. The levels of radioactivity for 238 U, 232 Th, 226 Ra, 210 Pb, 210 Po, 90 Sr, 137 Cs and 239+240 Pu were ND-5.2 Bq/kg fresh weight, ND-0.18 Bq/kg fresh weight, ND-3.9 Bq/kg fresh weight, ND-45 Bq/kg fresh weight, ND-120 Bq/kg fresh weight, ND-9.9 Bq/kg fresh weight, ND-19 Bq/kg fresh weight and ND-0.010 Bq/kg fresh weight, respectively. The committed effective dose was estimated to be 0.80 mSv from the intake of the foods. The effective dose was greater than the world mean value for adults of 0.12 mSv by natural radioactive elements in the uranium and thorium series from the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) 2000 because of the large contribution from 210 Po in seafood. (author)

  17. Evaluation of therapeutic effect of low dose naltrexone in experimentally-induced Crohn's disease in rats.

    Science.gov (United States)

    Tawfik, Dina Ibrahim; Osman, Afaf Sayed; Tolba, Hedayat Mahmoud; Khattab, Aida; Abdel-Salam, Lubna O; Kamel, Mahmoud M

    2016-10-01

    Crohn's disease is a relapsing inflammatory condition afflicting the digestive tract. Drugs used for treatment of Crohn's disease may be associated with serious side effects. Endogenous opioid peptides modulate inflammatory cytokine production. Opioid antagonists have been shown to play a role in healing and repair of tissues. This work was designed to detect the possible beneficial effects of opioid antagonist naltrexone in indomethacin-induced Crohn's disease in rats. Enteritis was induced in male albino rats by two subcutaneous injection of indomethacin in a dose of 7.5mg/kg 24h apart started on day one. Salfasalazine, naltrexone and their combination were administered orally from day one of induction of enteritis to day 10. Disease activity index, serum levels of C-reactive protein and tumor necrosis factor-α, macroscopic and microscopic pathological scores and in vitro motility studies were evaluated. Induction of enteritis resulted in significant increase of disease activity index, significant elevation of serum levels of C-reactive protein and tumor necrosis factor-α, significant deterioration of pathological scores and significant increase in the mean contractility response of the isolated ileal segments compared with normal untreated rats. Treatment with sulfasalazine, low dose of natrexone or their combination resulted in significant improvement of all measured parameters compared with enteritis group. The current finding could provide new interesting opportunity for developing new therapeutic approaches for treatment of Crohn's disease. Use of naltrexone, especially in small dose, has little side effects making it of interest for treatment of Crohn's disease. Also, it provides the possibility of reduced doses of other drugs if it is used as combined therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Evaluation of annual effective dose from indoor radon concentration in Eastern Province, Dammam, Saudi Arabia

    Science.gov (United States)

    Abuelhia, E.

    2017-11-01

    The aim of this study is to determine the indoor radon concentration and to evaluate the annual effective dose received by the inhabitants in Dammam, Al-Khobar, and compare it with new premises built at university of dammam. The research has been carried out by using active detection method; Electronic Radon Detector (RAD-7) a solid state α-detector with its special accessories. The indoor radon concentration measured varies from 10.2 Bqm-3 to 25.8 Bqm-3 with an average value of 18.8 Bqm-3 and 19.7 Bqm-3 to 23.5 Bqm-3 with an average value of 21.7 Bqm-3, in Dammam and Al-khobar dwellings, respectively. In university of dammam the radon concentration varies from 7.4 Bqm-3 to 15.8 Bqm-3 with an average value of 9.02 Bqm-3. The values of annual effective doses were found to be 0.47mSv/y, 0.55mSv/y, and 0.23mSv/y, in Dammam, Al-khobar and university new premises, respectively. The average radon concentration in the old dwellings was two times compared to that in the new premises and it was 25.4 Bqm-3 lower than the world average value of 40 Bqm-3 reported by the UNSCEAR. The annual effective doses in the old dwellings was found to be (0.55mSv/y) two times the doses received at the new premises, and below the world wide average of 1.15mSv/y reported by ICRP (2010). The indoor radon concentration in the study region is safe as far as health hazard is concerned.

  19. Shielding effect of building to natural radiation and its influence to population dose evaluation

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Itoh, Kazuo; Yoshimura, Toshiaki.

    1980-01-01

    This work investigated the shielding effect of the building which is indispensable for the accurate evaluation of the population dose of external exposure from natural radiation. At first, the attenuation coefficients of various building materials were measured and found to agree with the calculated values within 10% errors. The shielding factors of these materials were calculated from the calculated attenuation coefficients and buildup factors. The shielding factors of the wall, window, roof and floor were calculated separately by settling the model houses and combining the shielding factors of the building materials used, and then the shielding factor of the whole building was obtained by use of the opening fraction of the wall and the fractions of the wall, roof and floor areas to the total floor area. The influence of the shielding effect of the building is well represented by the occupancy factor which is the ratio of the group doses including that shielding effect to those excluding it. The occupancy factor lies between 0.9 and 1.0 for four specified districts, Tokyo, Osaka, Ibaraki and Nagano. (author)

  20. Evaluation of the anode heel effect on the testes dose during pelvic radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-05-01

    Full Text Available Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male patients undergoing pelvic radiography. Methods: This is a cross-sectional study, conducted at one of the teaching hospitals of Ahvaz, Jundishapur University of Medical Science Ahvaz, Iran, from September 2015 to March 2016. In order to measure the profile of radiation intensity variation, 13 paired sets of high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD aligned on the cathode-anode central axis upon the table and then irradiated using routine exposure parameters. The anode of X-ray tube was positioned toward the feet for 40 patients and toward the head for 39 patients undergoing pelvic radiography. For measure the entrance skin dose (ESD, 8 TLD chips were located on the central point of the radiation field and 5 TLDs were located on the testes position to measure the dose received. Results: Radiation intensity profile showed that radiation intensity decrease from the cathode to the anode side. Discrepancy of radiation intensity on central axis of cathode-anode was calculated about 35%. The radiation dose received by the testes was 26.74% lower for patients the anode directed toward the feet, compared to the patients in which the anode directed toward the head (FTC: 1.260±0.296 mGy, FTA: 0.923±0.167 mGy, P<0.05. There was no meaningful difference for the measured ESD of pelvis between two groups of patients (FTC: 1.256±0.315 mGy, FTA: 1.195±0.205 mGy, P=0.788. Conclusion: In pelvic radiography, positioning of testes directed to the anode of X-ray tube can decrease the receive dose.

  1. Evaluating low dose ionizing radiation effects on gene expression in human skin biopsy cores

    International Nuclear Information System (INIS)

    Goldberg, Z.; Schwietert, C.; Stern, R.L.; Lehnert, B.E.

    2003-01-01

    Significant biological effects can occur in animals, animal cells, immortalized human cell lines, and primary human cells after exposure to doses of ionizing radiation (IR) in the <1-10 cGy region. However it is unclear how these observations mimic or even pertain to the actual in vivo condition in humans, though such knowledge is required for reducing the uncertainty of assessing human risks due to low dose IR (LDIR) exposures. Further, low dose effects have increasing clinical relevance in the radiotherapeutic management of cancer as the volume of tissue receiving only LDIR increases as more targeted radiotherapy (i.e. IMRT) becomes more widely used. Thus, human translational data must be obtained with which to correlate in vitro experimental findings and evaluate their 'real-life' applicability. To evaluate LDIR effects in human tissue we have obtained freshly explanted full thickness human skin samples obtained from aesthetic surgery, and subjected them to ex vivo irradiation as a translational research model system of a complex human tissue. Ionizing radiation (IR) exposures were delivered at 1, 10, or 100 cGy. The temporal response to IR was assessed by harvesting RNA at multiple time points out to 24 hours post IR. Gene expression changes were assessed by real time PCR. We have shown that RNA can be reliably extracted with fidelity from 3 mm diameter punch biopsies of human tissue and provide good quality sample for the real time PCR evaluation. Genes of interest include those reported to have altered expression following LDIR from in vitro cell culture models. These include genes associated with cell cycle regulation, DNA repair and various cytokines. These feasibility studies in human skin irradiated ex vivo, have demonstrated that gene expression can be measured accurately from very small human tissue samples, thus setting the stage for biopsy acquisition of tissue irradiated in vivo from patients-volunteers. The clinical study has begun and the data from

  2. Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation.

    Science.gov (United States)

    Chow, James C L; Leung, Michael K K; Islam, Mohammad K; Norrlinger, Bernhard D; Jaffray, David A

    2008-01-01

    The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnr code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 degrees photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the

  3. Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chow, James C. L.; Leung, Michael K. K.; Islam, Mohammad K.; Norrlinger, Bernhard D.; Jaffray, David A.

    2008-01-01

    The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle3 treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnrc code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 deg. photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle3. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the

  4. Evaluation of gamma dose effect on PIN photodiode using analytical model

    Science.gov (United States)

    Jafari, H.; Feghhi, S. A. H.; Boorboor, S.

    2018-03-01

    The PIN silicon photodiodes are widely used in the applications which may be found in radiation environment such as space mission, medical imaging and non-destructive testing. Radiation-induced damage in these devices causes to degrade the photodiode parameters. In this work, we have used new approach to evaluate gamma dose effects on a commercial PIN photodiode (BPX65) based on an analytical model. In this approach, the NIEL parameter has been calculated for gamma rays from a 60Co source by GEANT4. The radiation damage mechanisms have been considered by solving numerically the Poisson and continuity equations with the appropriate boundary conditions, parameters and physical models. Defects caused by radiation in silicon have been formulated in terms of the damage coefficient for the minority carriers' lifetime. The gamma induced degradation parameters of the silicon PIN photodiode have been analyzed in detail and the results were compared with experimental measurements and as well as the results of ATLAS semiconductor simulator to verify and parameterize the analytical model calculations. The results showed reasonable agreement between them for BPX65 silicon photodiode irradiated by 60Co gamma source at total doses up to 5 kGy under different reverse voltages.

  5. Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms.

    Science.gov (United States)

    Lee, Hyun Cheol; Yoo, Do Hyeon; Testa, Mauro; Shin, Wook-Geun; Choi, Hyun Joon; Ha, Wi-Ho; Yoo, Jaeryong; Yoon, Seokwon; Min, Chul Hee

    2016-04-01

    The aim of this study is to evaluate the potential hazard of naturally occurring radioactive material (NORM) added consumer products. Using the Monte Carlo method, the radioactive products were simulated with ICRP reference phantom and the organ doses were calculated with the usage scenario. Finally, the annual effective doses were evaluated as lower than the public dose limit of 1mSv y(-1) for 44 products. It was demonstrated that NORM-added consumer products could be quantitatively assessed for the safety regulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Radiological Evaluation of the effects of varied doses of Celecoxib on fracture healing in dogs

    Directory of Open Access Journals (Sweden)

    Edwin Aihanuwa Uwagie-Ero and Rapheal Chukwujekwu Kene

    2011-04-01

    Full Text Available To determine if Cyclooxygenase -2 (COX-2 functions in fracture healing, 10 dogs were treated with COX-2-selective nonsteroidal anti-inflammatory drugs (Celecoxib to reduce and stop COX-2-dependent prostaglandin production. Radiographic testing evaluation determined that fracture healing was not affected in dogs treated with a low dose of COX-2-selective NSAIDs (celecoxib and delayed union was observed in dogs treated with a high dose of COX-2-selective NSAIDs (celecoxib. Celecoxib dose of 5 mg/kg/day did not affect fracture callus formed in the study group and did not cause a significant increase in the proportion of delayed unions, however, at a dose of 10 mg/kg/day it reduced the rate of fracture callus formation and significantly increased the proportion of delayed unions for dogs in the group. [Veterinary World 2011; 4(2.000: 75-76

  7. Evaluation of Patient Radiation Dose during Cardiac Interventional Procedures: What Is the Most Effective Method?

    International Nuclear Information System (INIS)

    Chida, K.; Saito, H.; Ishibashi, T.; Zuguchi, M.; Kagaya, Y.; Takahashi, S.

    2009-01-01

    Cardiac interventional radiology has lower risks than surgical procedures. This is despite the fact that radiation doses from cardiac intervention procedures are the highest of any commonly performed general X-ray examination. Maximum radiation skin doses (MSDs) should be determined to avoid radiation-associated skin injuries in patients undergoing cardiac intervention procedures. However, real-time evaluation of MSD is unavailable for many cardiac intervention procedures. This review describes methods of determining MSD during cardiac intervention procedures. Currently, in most cardiac intervention procedures, real-time measuring of MSD is not feasible. Thus, we recommend that physicians record the patient's total entrance skin dose, such as the dose at the interventional reference point when it can be monitored, in order to estimate MSD in intervention procedures

  8. Evaluation the effect of low-dose aspirin on endothelial dysfunction in preeclamptic patients

    Directory of Open Access Journals (Sweden)

    Mohammad Hashemi

    2016-01-01

    Full Text Available Background: Preeclampsia complicates up to 3% of pregnancies in developing countries. Endothelial dysfunction plays an important role in pathogenesis of preeclampsia. In this study, we aim to evaluate the effect of low-dose aspirin on endothelial dysfunction in preeclamptic patients. Materials and Methods: in this triple-blind randomized clinical trial, enrolled patients were divided randomly into two groups. Acetylsalicylic acid (ASA 80 mg or placebo will be taken daily by oral administration from the initiation of diagnosis until 2 months after delivery. Every patient's flow-mediated dilation (FMD were evaluated at the beginning of study and 2 months after delivery with the same experienced operator at a same period of the time (3–5 pm by high-resolution B-mode ultrasonographic. T-test or Mann–Whitney test was used in the comparison of means between the intervention and placebo groups. To compare FMD in each group, before and after the intervention, paired t-test was used. Results: Mean value of FMD in intervention (9.61 ± 5.58 and control group (9.40 ± 4.33 have no significant differences before drug consumption (P = 0.089. FMD in intervention group significantly increased after ASA consumption ([9.61 ± 5.58 vs. 13.65 ± 7.91] [P = 0.044]. Conclusion: Increase mean of FMD in intervention group shows that this supplement can improve endothelial function.

  9. Evaluation of the effective dose equivalent to tbe public of Pavia after the Chernobyl nuclear accident

    International Nuclear Information System (INIS)

    Altieri, S.; Berzero, A.; Meloni, S.; Rosti, G.; Genova, N.

    1988-01-01

    The Chernobyl radionuclide monitoring campaign in air particulate and foodstuffs was carried out and continued up to June 1987. On the basis of collected data estimates of the collective effective dose equivalent commitment to the public of province of Pavia, by external irradiation or by inhalation, were carried out and are reported in the present paper

  10. Effective dose evaluation for workers assisting new-borns in nuclear medicine procedures

    International Nuclear Information System (INIS)

    Falivene, A.; Gori, C.; Mazzocchi, S.; Targetti, S.; Zatelli, G.

    2002-01-01

    Renal scintigraphy is a very frequent nuclear medicine procedure for new-borns when deemed necessary after prenatal ultrasounds investigation. The procedure requires the physical proximity of workers to the patient, particularly during the examination of new-borns, in order to keep the young patients still. The irradiation of nurses during kidney examination of new-borns has been measured by simulating the examination procedure with an Alderson Rando phantom stuffed with thermoluminescent detectors, positioned near a radioactive source obtained with a tank filled with a 9 9mT c solution. Measurements have been carried out both with and without radiation protection devices positioned on the Rando phantom. Different organ doses have been evaluated. The aim of this analysis is to evaluate the amount of dose reduction that can be achieved by utilising lead aprons, glasses and thyroid collars

  11. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  12. Optimisation need of dental radiodiagnostic procedures: results of effective dose evaluation from Rando phantom measurements

    International Nuclear Information System (INIS)

    Borio, R.; Chiocchini, S.; Cicioni, R.; Degli Esposti, P.; Rongoni, A.; Sabatini, P.; Saetta, D.M.S.; Regi, L.; Caprino, G.

    1994-01-01

    Radiological examinations of different types are needed in dental practice both to make a correct diagnosis and to carry out an adequate therapy. Particularly in orthodentic practices, because of the youth of the majority of the patients, an assessment of the detriment to health (through the effective dose equivalent) caused by medical diagnostic exposure to ionising radiation is needed to make decisions about the optimisation of dental radiodiagnostic procedures. Experimental data from measurements on a Rando phantom were collected for the radiological examinations required for dental and for orthodontic practices (with and without protective apron and collar). The results show the effectiveness of the leaded apron and collar in all the examinations carried out, particularly in reducing thyroid dose. (author)

  13. Evaluation of the collective effective dose equivalent of atmospheric discharges in the Rhone valley

    International Nuclear Information System (INIS)

    Le Grand, J.; Despres, A.; Robeau, D.; Bouville, A.

    1982-01-01

    Two models were used to evaluate the integrated atmospheric concentrations: - TALD, a long-range atmospheric transport model which takes account of the actual trajectories of the discharged matter; - a Gaussian plume model which assumes straight-line trajectories defined by the wind at the point of emission. In order to bring out the differences due to the use of the two models the dose equivalents are presented as a function of wind direction at the point of emission and the contributions of the near zone and the further zone are compared. (author)

  14. Numerical model for atmospheric diffusion analysis and evaluation of effective dose for safety analysis

    International Nuclear Information System (INIS)

    Sada, Koichi; Michioka, Takenobu; Ichikawa, Yoichi; Komiyama, Sumito

    2009-01-01

    A numerical simulation method has been developed to predict atmospheric flow and stack gas diffusion, considering the buildings and complex terrain located near and relatively far from a stack, respectively. The turbulence closure technique was used for flow calculation, some calculation grids on the ground near a stack were treated as buildings, and stack gas diffusion was predicted using the Lagrangian particle model. The calculated flow and stack gas diffusion results were compared with those obtained by wind tunnel experiments under actual terrain containing buildings. Effective stack height was estimated by comparing the surface concentration along the plume axis with those under a flat-plate condition, and it was apparent that the effective stack heights estimated by calculations were almost the same as those obtained by the wind tunnel experiment. Then, the effective dose and relative concentration of stack gas were calculated using the effective stack heights obtained by a numerical model. Almost the same effective dose and relative concentration were obtained when compared with those using the effective stack height obtained by wind tunnel experiment. (author)

  15. A repository released-dose model for the evaluation of long-lived fission product transmutation effectiveness

    International Nuclear Information System (INIS)

    Davidson, J.W.

    1995-01-01

    A methodology has been developed to quantify the total integrated dose due to a radionuclide species i emplaced in a geologic repository; the focus is on the seven long-lived fission products (LLFPs). The methodology assumes continuous exposure water contaminated with species i at the accessible environment (i.e., just beyond the geologic barrier afforded by the geologic repository). The dose integration is performed out to a reference post-release time. The integrated dose is a function of the total initial inventory of radionuclide i the repository, the time at which complete and instantaneous failure of the engineered barrier (e.g., waste canister) in, a geologic repository occurs, the fractional dissolution rate (from waste solid form) of radionuclide i in ground water, the ground water travel time to the accessible environment, the retardation factor (sorption on the geologic media) for radionuclide i, the time after radionuclide begins to enter the biosphere. In order to assess relative dose, the ratio of total integrated dose to that for a reference LLFP species j (e.g., 99 Tc) was defined. This ratio is a measure of the relative benefit of transmutation of other LLFPs compared to 99 Tc. This methodology was further developed in order to quantify the integrated dose reduction per neutron utilized for LLFP transmutation in accelerator-driven transmutation technologies (ADTT). This measure of effectiveness is a function of the integrated dose due to LLFP species i, the number of total captures in LLFP species i chain per LLFP nuclide fed to the chain at equilibrium, and the number of total captures in related transmutation product (TP) chains per capture in the LLFP species i chain. To assess relative transmutation effectiveness, the ratio of integrated dose reduction per neutron utilization to that for a reference LLFP species j (e.g., 99 Tc) was defined. This relative measure of effectiveness was evaluated LLFP transmutation strategy

  16. The basic approaches to evaluation of effects of the long-therm radiation exposure in a range of 'low' doses

    International Nuclear Information System (INIS)

    Takhauov, R.M.; Karpov, A.B.; Litvyakov, N.V.

    2010-01-01

    The previously performed research allowed forming the main concepts about deterministic effects of radiation impact and defining the main postulates of radiation medicine with respect to average and high levels of exposure. At the same time the research performed to evaluate stochastic effects caused by 'low' doses of ionizing radiation influence failed to find a single-valued answer relating both to dose impact inducing the effect development and to the spectrum of recorded pathologic processes or diseases. In this connection on our opinion the most prospective decision of present problem are studies in follow directions: 1. The evaluation of radiation productions personal and residents of nearby territories mortality and morbidity structure and dynamics. 2. The estimation of risk main diseases development with long-term radiation exposure and analysis of radiation factor role in its pathogenesis. 3. The study of genetic disturbances of persons and their descendants exposed long-term ionizing radiation in 'low' doses. 4. The study of individual radio sensitivity genetic markers. 5. The evaluation of structural and functional homeostasis disturbances inducing the radiation exposure in 'low' doses. The object of study is the Close administrative territorial formation Seversk population and mainly Siberian Group Chemical Enterprises (SGCE) personal - the largest complex productions of atomic industry in the world. The Regional Medico-Dosimetric Register (RMDR), creating since 2001 is the basis for epidemiological studies. The register database contain the information concerning to about 66 000 SGCE workers (it is a whole number of workers in all years of SGCE existence from 1950 to now day). The 35 000 from 66 000 workers are the workers of so-called main productions. About 96% workers exposed external radiation has cumulative dose less 500 mSv. On the base of laboratory of genomic medicine it was created and constantly enriched the bank DNA and biological material

  17. Clinical Pharmacokinetics of IPX066: Evaluation of Dose Proportionality and Effect of Food in Healthy Volunteers.

    Science.gov (United States)

    Yao, Hsuan-Ming; Hsu, Ann; Gupta, Suneel; Modi, Nishit B

    2016-01-01

    IPX066 is an oral, extended-release capsule formulation of carbidopa-levodopa (CD-LD) available in 4 strengths. The goals of this investigation were to assess the dose proportionality of IPX066 and to study the effects of a high-fat, high-calorie meal and of sprinkling the capsule contents on applesauce on the pharmacokinetics of IPX066 in healthy volunteers. Three open-label studies were conducted. In the first study, subjects received 1 capsule of each IPX066 strength (23.75-95, 36.25-145, 48.75-195, and 61.25-245 mg of CD-LD). In the second study, subjects received 1 and 2 capsules of IPX066 245-mg LD under fasting conditions. In the third study, subjects received 2 capsules of IPX066 245-mg LD under 3 conditions: fasting; following a high-fat, high-calorie breakfast; and with the capsule contents sprinkled on applesauce under fasting conditions. Peak plasma concentrations (Cmax) and systemic exposure (AUCt, AUCinf) for LD and CD increased dose-proportionally over the range of the IPX066 capsule strengths. Comparison of 1 and 2 IPX066 245-mg LD capsules showed dose-proportional pharmacokinetics for Cmax and AUCt. Sprinkling the capsule contents on applesauce did not affect the pharmacokinetics. A high-fat, high-calorie meal delayed the initial increase in LD concentration by approximately 1 to 2 hours, reduced Cmax by 21%, and increased AUCinf by 13% compared with the fasted state. IPX066 shows dose-proportional pharmacokinetics. Sprinkling the capsule contents on applesauce does not affect the pharmacokinetics; a high-fat, high-calorie meal delayed absorption by 1 to 2 hours, slightly reduced Cmax, and slightly increased extent of absorption.

  18. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  19. Evaluation of the effective equivalent dose in the general public due to the discharge of uranium in groundwater

    International Nuclear Information System (INIS)

    Gordon, A.M.P.L.; Jacomino, V.M.F.

    1989-12-01

    Some facilities available at IPEN-CNEN/SP may discharge uranium in their liquid effluents. The uranium contents of these effluents are analyzed by photometry or fluorimetry, and according to the results obtained a decision is made, by the Environmental Monitoring Division, upon their discharge to the environment. In 1988 a total activity of 3.66x10 9 Bq of uranium was discharge in a volume of approximately 30 m 3 . The effective equivalent dose in the general public was evaluated by making a conservative assumption that all the liquid effluents containing uranium are discharged directly to the soil reaching the groundwater. The dose calculation was carried out by using a generic model which described the transport of radionuclides in the groundwater. In order to be conservative it was also assumed that the critical pathway is the direct in gestion of water through hypothetical wells around the Institute. Conservative assumptions were also made in the characterization of the local aquifer parameters such as vertical and longitudinal dispersivity, effective porosity of the soil, hydraulic conductivity etc., in roder to overestimate the effective equivalent dose. The result obtained, of 5.3x10 -10 mSv/a is far below the dose limit for the public adopted by the Radiological Protection Board. The derived limit for the discharge was also evaluated, using the same model, giving a result of 3.6x10 13 Bq/a. (author) [pt

  20. Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2014-12-15

    To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

  1. Study of the heterogeneity effects of lung in the evaluation of absorbed dose in radiotherapy

    International Nuclear Information System (INIS)

    Campos, Luciana Tourinho

    2006-02-01

    The main objective of radiotherapy is to deliver the highest possible dose to the tumour, in order to destroy it, reducing as much as possible the doses to healthy tissues adjacent to the target volume. Therefore, it is necessary to do a planning of the treatment. The more complex is the treatment, the more difficult the planning will be, demanding computation sophisticated methods in its execution, in order to consider the heterogeneities present in the human body. Additionally, with the appearing of new radiotherapeutic techniques, that used irradiation fields of small area, for instance, the intensity modulated radiotherapy, the difficulties for the execution of a reliable treatment planning, became still larger. In this work it was studied the influence of the lung heterogeneity in the planning of the curves of percentage depth dose, PDP, obtained with the Eclipse R planning system for different sizes of irradiation fields, using the correction algorithms for heterogeneities available in the planning system: modified Batho, general Batho and equivalent tissue-air ratio. A thorax phantom, manufactured in acrylic, containing a region made of cork to simulate the lung tissue, was used. The PDP curves generated by the planning system were compared to those obtained by Monte Carlo simulation and with the use of thermoluminescent, TL, dosimetry. It was verified that the algorithms used by the Eclipse R system for the correction of heterogeneity effects are not able to generate correct results for PDP curves in the case of small fields, occurring differences of up to 100%, when the 1x1 cm 2 treatment field is considered. These differences can cause a considerable subdosage in the lung tissue, reducing the possibility of the patient cure. (author)

  2. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  3. Evaluation of equivalent and effective dose by KAP for patient and orthopedic surgeon in vertebral compression fracture surgery

    International Nuclear Information System (INIS)

    Santos, Felipe A.; Galeano, Diego C.; Santos, William S.; Silva, Ademir X.; Souza, Susana O.; Carvalho Júnior, Albérico B.

    2017-01-01

    in VCF surgeries. • Results allow evaluation of effective doses to patients and surgeon.

  4. BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Huber, Kathryn E.; Mignano, John E.; Duker, Jay S.; Laver, Nora V.; Rivard, Mark J.

    2012-01-01

    Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with 103 Pd, 125 I, or 131 Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( TUMOR D 90 ) and 10% of the organ at risk volumes ( OAR D 10 ) were calculated. The BED equation from Dale and Jones and published α/β and μ parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., TUMOR 7 BED 10 and OAR 7 BED 10 ). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on TUMOR BEDVH and OAR BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: TUMOR D 90 values were 102, 112, and 110 Gy for 103 Pd, 125 I, and 131 Cs, respectively. Corresponding TUMOR 7 BED 10 values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, TUMOR 7 BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused TUMOR 7 BED 10 to deviate by up to 46%. Over the range of OAR α/β values, OAR 7 BED 10 varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the

  5. Dose response toxic effects of different oximes in vivo: pathohystological evaluation

    International Nuclear Information System (INIS)

    Jacevic, V.

    2009-01-01

    The acute toxicity of oximes is crucial for the assessment of a dose applied as a treatment for organophosphorus intoxications. This is why we decided to investigate which morphological lesions could be produced in Wistar rats after treatment with increasing doses of HI-6, Obidoxime, K027, K048, and K075. In the first part of this study, tested oximes were preliminarily tested in order to obtain their LD50 values. Survival rates were monitored 24 hours after application of each oxime. In separate experiment animals were sacrificed 7 days after single im application of 0.1 LD50 and 0.5 LD50 of each oxime, and hearts, diaphragms and musculus popliteus were obtained for pathohistological analysis. Tissue damage score (TDS) was based on an estimation scale from 0 (no damage) to 5 (strong damage, massive necrotic fields). In rats treated with of 0.1 LD50 of HI-6 and K027 microscopic findings were similar to those evaluated in the control groups, only. More intensive alterations, but still mild and reversible degenerative and vascular changes, were established in tissue samples after treatment with 0.1 LD50 of Obidoxime, K048 and K075, but their values were also similar to the control group. Acute lesions were developed in tissue samples within 7 days following treatment with 0.5 LD50 of all oximes. The most severe tissue alterations were found in rats treated with 0.5 LD50 of K048 and K075 (p < 0.001 vs. control and HI-6). These observations of the earliest tissues events are helping to guide of applications of novel development oximes.(author)

  6. Effective doses in paediatric radiology

    International Nuclear Information System (INIS)

    Iacob, Olga; Diaconescu, Cornelia; Roca, Antoaneta

    2001-01-01

    Because of their longer life expectancy, the risk of late manifestations of detrimental radiation effects is greater in children than in adults and, consequently, paediatric radiology gives ground for more concern regarding radiation protection than radiology of adults. The purpose of our study is to assess in terms of effective doses the magnitude of paediatric patient exposure during conventional X-ray examinations, selected for their high frequency or their relatively high doses to the patient. Effective doses have been derived from measurements of dose-area product (DAP) carried out on over 900 patients undergoing X-ray examinations, in five paediatric units. The conversion coefficients for estimating effective doses are those calculated by the NRPB using Monte-Carlo technique on a series of 5 mathematical phantoms representing 0, 1, 5, 10 and 15 year old children. The annual frequency of X-ray examinations necessary for collective dose calculation are those reported in our last national study on medical exposure, conducted in 1995. The annual effective doses from all medical examinations for the average paediatric patient are as follows: 1.05 mSv for 0 year old, 0.98 mSv for 1 year old, 0.53 mSv for 5 year old, 0.65 mSv for 10 year old and 0.70 mSv for 15 year old. The resulting annual collective effective dose was evaluated at 625 man Sv with the largest contribution of pelvis and hip examinations (34%). The annual collective effective associated with paediatric radiology in Romania represent 5% of the annual value resulting from all diagnostic radiology. Examination of the chest is by far the most frequent procedure for children, accounting for about 60 per cent of all annually performed X-ray conventional examinations. Knowledge of real level of patient dose is an essential component of quality assurance programs in paediatric radiology. (authors)

  7. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  8. Manual of dose evaluation from atmospheric releases

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Abrol, V [Health Physics Division, Bhabha Atomic Research Centre, Bombay (India)

    1978-07-01

    The problem of dose evaluation from atmospheric releases is reduced to simple arithmetic by giving tables of concentrations and time integrated concentrations for instantaneous plumes and long time (1 year), sector averaged plumes for distances upto 10 km, effective release heights of upto 200 m and the six Pasquill stability classes. Correction factors for decay, depletion due to deposition and rainout are also given. Inhalation doses, immersion doses and contamination levels can be obtained from these by using multiplicative factors tabulated for various isotopes of significance. Tables of external gamma doses from plume are given separately for various gamma energies. Tables are also given to evaluate external beta and gamma dose rates from contaminated surfaces. The manual also discusses the basic diffusion model relevant to the problem. (author)

  9. An algorithm to evaluate solar irradiance and effective dose rates using spectral UV irradiance at four selected wavelengths

    International Nuclear Information System (INIS)

    Anav, A.; Rafanelli, C.; Di Menno, I.; Di Menno, M.

    2004-01-01

    The paper shows a semi-analytical method for environmental and dosimetric applications to evaluate, in clear sky conditions, the solar irradiance and the effective dose rates for some action spectra using only four spectral irradiance values at selected wavelengths in the UV-B and UV-A regions (305, 320, 340 and 380 nm). The method, named WL4UV, is based on the reconstruction of an approximated spectral irradiance that can be integrated, to obtain the solar irradiance, or convoluted with an action spectrum to obtain an effective dose rate. The parameters required in the algorithm are deduced from archived solar spectral irradiance data. This database contains measurements carried out by some Brewer spectrophotometers located in various geographical positions, at similar altitudes, with very different environmental characteristics: Rome (Italy), Ny Aalesund (Svalbard Islands (Norway)) and Ushuaia (Tierra del Fuego (Argentina)). To evaluate the precision of the method, a double test was performed with data not used in developing the model. Archived Brewer measurement data, in clear sky conditions, from Rome and from the National Science Foundation UV data set in San Diego (CA, USA) and Ushuaia, where SUV 100 spectro-radiometers operate, were drawn randomly. The comparison of measured and computed irradiance has a relative deviation of about ±2%. The effective dose rates for action spectra of Erythema, DNA and non-Melanoma skin cancer have a relative deviation of less than ∼20% for solar zenith angles <50 deg.. (authors)

  10. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  11. SU-C-18C-04: Evaluation of Effective Dose During Ureteroscopy for Obese and Non-Obese Patients

    Energy Technology Data Exchange (ETDEWEB)

    Wang, C; Nguyen, G; Chung, Y; Yoshizumi, T [Duke University, Durham, NC (United States); Cabrera, F; Lipkin, M [Duke University Medical Center, Durham, NC (United States); Shin, R [Duke University Medical Center, Durham, North Carolina (United States)

    2014-06-01

    Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for

  12. SU-C-18C-04: Evaluation of Effective Dose During Ureteroscopy for Obese and Non-Obese Patients

    International Nuclear Information System (INIS)

    Wang, C; Nguyen, G; Chung, Y; Yoshizumi, T; Cabrera, F; Lipkin, M; Shin, R

    2014-01-01

    Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for

  13. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  14. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  15. Decision of special monitoring time to minimize the difference of the committed effective dose evaluated from the different AMAD

    International Nuclear Information System (INIS)

    Lee, J. I.; Lee, T. Y.; Jang, S. Y.; Lee, J. K.

    2003-01-01

    The Committed Effective Doses (CEDs) per measured unit of activity in the bioassay compartments at any time (t) after an acute intake by the inhalation of a radionuclide with a different particle size (AMAD) were calculated and compared. As a result, the relative difference between the CEDs evaluated from the different AMAD is affected by the radionuclide, bioassay compartment, and the time (t) after intake. Therefore a special monitoring time to exclude or reduce the effect of AMAD was decided and presented in the evaluation for the CEDs following an acute intake by the inhalation of a radionuclide. If special monitoring is performed during this presented special time after intake, the relative difference of the evaluated CEDs resulted from AMAD can be excluded or reduced

  16. Evaluation for committed effective dose due to dietary foods by the intake for Japanese adults

    International Nuclear Information System (INIS)

    Sanada, Tetsuya

    2011-01-01

    Explained are the internal exposure (IE) in Japanese adults due to the ordinary intake of food and the committed effective dose (CED) derived from it, which can be the basic reference data for estimating CED at emergency like the recent Fukushima Disaster. IE lasts as long as radioactive substances exist in the body and its health risk is assessed throughout the lifetime, 50 years in adult and in children until their age of 70 years, by CED based on consideration of the physical and biological halftimes of radionuclides involved. CED (mSv) is calculated by an equation given in International Commission of Radiological Protection (ICRP) Pub. 72, using radioactivity level (Bq/kg), intake (kg/y) and age-dependent dose coefficient (mSv/Bq). Japan MEXT in its homepage (http://www.kankyo-hoshano.go.jp/) publishes the states of environmental radioactivity levels including those of daily Japanese food. The food survey of yearly changes of radioactivity level (Bq/man/day) indicates that, when compared with the level in 2009, it is two times higher in 1970s due to old in-atmospheric nuclear experiments, and is decreased gradually with a temporary peak around 1986 by Chernobyl accident. Studies on certain natural and artificial radioisotopes in 240 kinds of current food in 1989-2005 reveal that Po-210 level in fishes and shellfishes is particularly higher than others like St-90, Cs-137, Rd-226, Pb-210 and so on. CED in adults is calculated from yearly intake of foods (kg/y), their radioactivity (Bq/y) and the coefficient above, to be 0.80 mSv, and 0.98 mSv when the contribution of K-40 is taken in calculation. The proportion of the contribution in the latter estimated CED accounts for 74% (0.73 mSv) by Po-210 and for 18% (0.18 mSv) by K-40, which is conceivably derived from intake of more seafood by Japanese than other people in the world (average 0.070 and 0.17 mSv, respectively). (T.T.)

  17. Evaluation of the effect of change in the radiosensitive tissue weights listed in the ICRP in estimate of effective dose

    International Nuclear Information System (INIS)

    Vieira, Jose W.; Leal Neto, Viriato; Lopes Filho, Ferdinand J.; Lima Filho, Jose M.; Santana, Ivan E.; Andrade, Pedro H.A.; Cabral, Manuela O.M.

    2015-01-01

    For photons and electrons, the effective dose by gender is a weighted sum of the absorbed doses in radiosensitive organs and tissue of the human body. Effective dose is estimated using Exposure Computational Models (ECM) of both genders for the same age group. The FSTA and MSTA ECMs were developed by researchers from DEN/UFPE and consist of voxel phantoms representing adults coupled to EGSnrc Monte Carlo Code, which, in the folder designed for users of EGS, codes were added to simulate some radioactive sources. The reports 60 and 103 of the ICRP provide the factors that weigh the radiosensitivity of organs and tissues (W T ) required to estimate the effective dose. The two lists were placed in the FSTA and MSTA to simulate radiodiagnostic examination in different regions of the body (cranium, abdomen and thorax). The dosimetric data produced allowed an analysis of the effect of the change in the w T from the report 60 to the 103. The highest mean percent relative error, 64.3%, occurred in the results for the cranium due to the increase of the w T for most of the organs and tissues in the head and trunk in the updated list. In this case, it can be concluded that the values of the effective dose with the wT of the ICRP 60 were underestimated. Other types of simulators of radioactive sources can be used in investigating this problem and other variables related to the phantom can be considered for that proposes a W T 's list specific for the Brazilian population or recommend unrestricted use the ICRP data. (author)

  18. Evaluation of the effect of change in the radiosensitive tissue weights listed in the ICRP in estimate of effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Jose W.; Leal Neto, Viriato; Lopes Filho, Ferdinand J.; Lima Filho, Jose M.; Santana, Ivan E., E-mail: jose.wilson@recife.ifpe.edu.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco, (IFPE), Recife, PE (Brazil); Andrade, Pedro H.A.; Cabral, Manuela O.M. [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Lima, Vanildo J.M. [Universidade Federal de Pernambuco (DA/UFPE), Recife, PE (Brazil). Departamento de Anatomia; Lima, Fernando R.A., E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN/CNEN-NE), Recife, PE (Brazil)

    2015-07-01

    For photons and electrons, the effective dose by gender is a weighted sum of the absorbed doses in radiosensitive organs and tissue of the human body. Effective dose is estimated using Exposure Computational Models (ECM) of both genders for the same age group. The FSTA and MSTA ECMs were developed by researchers from DEN/UFPE and consist of voxel phantoms representing adults coupled to EGSnrc Monte Carlo Code, which, in the folder designed for users of EGS, codes were added to simulate some radioactive sources. The reports 60 and 103 of the ICRP provide the factors that weigh the radiosensitivity of organs and tissues (W{sub T}) required to estimate the effective dose. The two lists were placed in the FSTA and MSTA to simulate radiodiagnostic examination in different regions of the body (cranium, abdomen and thorax). The dosimetric data produced allowed an analysis of the effect of the change in the w{sub T} from the report 60 to the 103. The highest mean percent relative error, 64.3%, occurred in the results for the cranium due to the increase of the w{sub T} for most of the organs and tissues in the head and trunk in the updated list. In this case, it can be concluded that the values of the effective dose with the wT of the ICRP 60 were underestimated. Other types of simulators of radioactive sources can be used in investigating this problem and other variables related to the phantom can be considered for that proposes a W{sub T}'s list specific for the Brazilian population or recommend unrestricted use the ICRP data. (author)

  19. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A. [Federal University of Minas Gerais, Program of Nuclear Science and Techniques, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  20. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    International Nuclear Information System (INIS)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A.

    2015-10-01

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  1. Evaluation of acute toxicity and the effect of single injected doses of ...

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... significant in therapeutic applications against diseases of diverse origins .... The rats were killed under ether anesthesia; one hour after injection and blood ..... that zerumbone could be safe for use in one dose treatment.

  2. Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography

    International Nuclear Information System (INIS)

    Kim, Jung-Su; Yoon, Sang-Wook; Seo, Deok-Nam; Nam, So-Ra; Kim, Jung-Min

    2016-01-01

    Whole spine scanography (WSS) is a radiologic examination that requires whole body X-ray exposure. Consequently, the amount of patient radiation exposure is higher than the radiation dose following routine X-ray examination. Several studies have evaluated the patient effective dose (ED) following single exposure film-screen WSS. The objective of this study was to evaluate patient ED during WSS, based on the automatic image pasting method for multiple exposure digital radiography (APMDR). Further, the calculated EDs were compared with the results of previous studies involving single exposure film-screen WSS. We evaluated the ED of 50 consecutive patients (M:F = 28:22) who underwent WSS using APMDR. The anterior-posterior (AP) and lateral (LAT) projection EDs were evaluated based on the Monte Carlo simulation. Using APMDR, the mean number of exposures was 6.1 for AP and 6.5 for LAT projections. LAT projections required more exposures (6.55%) than AP projections. The mean ED was 0.6276 mSv (AP) and 0.6716 mSv (LAT). The mean ED for LAT projections was 0.6061 mSv in automatic exposure control (AEC) and 0.7694 mSv in manual mode. The relationship between dose-area-product (DAP) and ED revealed a proportional correlation (AP, R 2 = 0.943; LAT, R 2 = 0.773). Compared to prior research involving single exposure screen-film WSS, the patient ED following WSS using APMDR was lower on AP than on LAT projections. Despite multiple exposures, ED control is more effective if WSS is performed using APMDR in the AEC mode

  3. Biological effective dose evaluation in gynaecological brachytherapy: LDR and HDR treatments, dependence on radiobiological parameters, and treatment optimisation.

    Science.gov (United States)

    Bianchi, C; Botta, F; Conte, L; Vanoli, P; Cerizza, L

    2008-10-01

    This study was undertaken to compare the biological efficacy of different high-dose-rate (HDR) and low-dose-rate (LDR) treatments of gynaecological lesions, to identify the causes of possible nonuniformity and to optimise treatment through customised calculation. The study considered 110 patients treated between 2001 and 2006 with external beam radiation therapy and/or brachytherapy with either LDR (afterloader Selectron, (137)Cs) or HDR (afterloader microSelectron Classic, (192)Ir). The treatments were compared in terms of biologically effective dose (BED) to the tumour and to the rectum (linear-quadratic model) by using statistical tests for comparisons between independent samples. The difference between the two treatments was statistically significant in one case only. However, within each technique, we identified considerable nonuniformity in therapeutic efficacy due to differences in fractionation schemes and overall treatment time. To solve this problem, we created a Microsoft Excel spreadsheet allowing calculation of the optimal treatment for each patient: best efficacy (BED(tumour)) without exceeding toxicity threshold (BED(rectum)). The efficacy of a treatment may vary as a result of several factors. Customised radiobiological evaluation is a useful adjunct to clinical evaluation in planning equivalent treatments that satisfy all dosimetric constraints.

  4. Evaluation of effective and organ dose using PCXMC program in Duke phantom and added filter for computed radiography system

    International Nuclear Information System (INIS)

    Kang, Byung Sam; Park, Min Joo; Kim, Seung Chul

    2014-01-01

    By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose

  5. Evaluation of a combination of low-dose ketamine and low-dose midazolam in terminal dyspnea-attenuation of "double-effect"

    Directory of Open Access Journals (Sweden)

    Abhijit Kanti Dam

    2008-01-01

    Full Text Available Aim: Of all symptoms in palliative medicine those concerning respiration are most excruciating and difficult to treat. Reticence about the use of morphine for palliation of dyspnea is common, especially in nonmalignant diseases, as there is a fear of causing respiratory depression, particularly where Chronic Obstructive Pulmonary Disease (COPD exists. This factor is also compounded by the lack of availability of morphine in parts of developing countries. Ketamine has excellent anesthetic and analgesic effects in addition to being easily available. It produces bronchodilatation and does not produce respiratory or cardiovascular depression. The author seeks to evaluate the role of low-dose (0.2 mg/kg ketamine and midazolam (0.02 mg/kg in the attenuation of terminal dyspnea. Methods: Sixteen patients with terminal dyspnea, admitted to the Critical Care Unit (CCU with cancer and other noncancer diagnoses were recruited. The subjective component of dyspnea was assessed using the Graphic Rating Scale (GRS, which has values from 0 - 10, 10 being maximum dyspnea. Each patient received a low-dose of ketamine and midazolam for relief of dyspnea. All the patients received low-flow (2 L/min. oxygen therapy via nasal cannula. Immediately after admission, all the patients were reassured and nursed in a decubitus position of their choice. The GRS was recorded at the point of admission, 10 minutes after starting oxygen therapy, and ten minutes after administration of low-dose ketamine and midazolam. Hemodynamic parameters were also recorded at these three points. Result: All the patients who enrolled in our study had significant dyspnea at admission, as was evident from the GRS scores of 8.250 (SD 0.91, respiratory rate of 28.56 (SD 5.0, mean arterial blood pressure (MABP of 102.7 (SD 14.63, pulse rate of 115.62 (SD 23.3, and SpO2 of 92.43 (SD 2.38. All the patients benefited from the combination of ketamine and midazolam, as evidenced by the statistically

  6. Evaluation of low dose ionizing radiation effect on some blood components in animal model

    Directory of Open Access Journals (Sweden)

    H. El-Shanshoury

    2016-07-01

    The present findings suggest that damage from IR causes a significant reduction in blood cell counts in a dose-dependent manner, which may be considered a potential health risk during exposure to irradiation. Much effort must be done and focused on establishment of protocols for medical management of radiation injuries based on hematopoietic changes for biodosimetry.

  7. Review and Evaluation of Updated Research on the Health Effects Associated with Low-Dose Ionizing Radiation

    International Nuclear Information System (INIS)

    Dauer, Lawrence T.; Brooks, Antone L.; Hoel, David G.; Morgan, William F.; Stram, Daniel; Tran, Phung

    2010-01-01

    Potential health effects of low levels of radiation have predominantly been based on those effects observed at high levels of radiation. The authors have reviewed more than 200 percent publications in radiobiology and epidermiology related to low dose radiation and concluded that recent radiobiological studies at low-doses; that doses <100 mSv in a single exposure appear to be too small to allow epidermiological detection of statistically significant excess cancers in the presence of naturally occurring cancers; that low dose radiation research should to holistic, systems-based approaches to develop models that define the shape of the dose-response relationships at low doses; and that these results should be combined with the latest epidermiology to produce a comprehensive understanding of radiation effects that addresses both damage, likely with a linear effect, and response, possibly with non-linear consequences.

  8. Clinical evaluation of dose-volume-effect relationship in radiation injury of the brain

    International Nuclear Information System (INIS)

    Saito, Mari

    1990-01-01

    Radiation brain injury, including functional disturbances or morphological changes (brain atrophy, periventricular lucencies or ventricular dilatation), were studied by CT in patients with primary intracranial neoplasms who were followed-up for at least 5 months after receiving radiotherapy. Each of 33 patients with medulloblastoma, pinealregion tumor or malignant lymphoma received a total dose of 40-61 Gy by conventional fractionation using a whole brain irradiation field boosted by a localized field. Of these patients, 19 (58%) developed radiation brain injury. It was concluded that the volume-dose was one of the most important factors influencing the development of radiation brain injury. Age at the time of radiotherapy and time of follow-up after the treatment were also considered to be important factors. (author)

  9. Evaluation of the effective dose in an anthropomorphic phantom in radiation emergencies

    International Nuclear Information System (INIS)

    Silva, L.K.; Santos, D.S.

    2015-01-01

    This study aims to perform a modeling of the human anatomy using Voxel models applied to Monte Carlo code and the Visual Monte Carlo software, simulating irradiation of the human body, so you can make the dose assessment in individuals who have been exposed to any external ionizing radiation source. Making the future, an assessment of both results with limits of validity of TECDOC-1162 expressions of the IAEA in case of point source

  10. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  11. Evaluation of radiation doses from radioactive drugs

    International Nuclear Information System (INIS)

    Halperin, J.A.; Grove, G.R.

    1977-01-01

    Radioactive new drugs are regulated by the Food and Drug Administration (FDA) in the United States. Before a new drug can be marketed it must have an approved New Drug Application (NDA). Clinical investigations of a radioactive new drug are carried out under a Notice of Claimed Investigational Exemption for a New Drug (IND), submitted to the FDA. In the review of the IND, radiation doses are projected on the basis of experimental data from animal models and from calculations based upon radiation characteristics, predicted biodistribution of the drug in humans, and activity to be administered. FDA physicians review anticipated doses and prevent clinical investigations in humans when the potential risk of the use of a radioactive substance outweighs the prospect of achieving beneficial results from the administration of the drug. In the evaluation of an NDA, FDA staff attempt to assure that the intended diagnostic or therapeutic effect is achievable with the lowest practicable radiation dose. Radiation doses from radioactive new drugs are evaluated by physicians within the FDA. Important radioactive new drugs are also evaluated by the Radiopharmaceuticals Advisory Committee. FDA also supports the Center for Internal Radiation Dosimetry at Oak Ridge, to provide information regarding in vivo distribution and dosimetry to critical organs and the whole body from radioactive new drugs. The process for evaluation of radiation doses from radioactive new drugs for protection against use of unnecessary radiation exposure by patients in nuclear medicine procedures, a

  12. radioactivity analysis in food-stuffs and evaluation of annual effective doses from intakes of radionuclides through daily diets

    International Nuclear Information System (INIS)

    Alam, M.N.; Chowdhury, M. I.; Kamal, M.; Ghose, S.; Islam, M. N.; Mustafa, M. N.; Islam, Al Amin S.

    1996-01-01

    The concentrations of natural and anthropogenic gamma emitting radionuclides in different vegetables, grains,fishes, sugar and common salt samples were measured by using high purity germanium ( HPGe ) detector coupled with Personal Computer Analyzer ( PCA ) and thereby the effective doses from the consumption of these diet were evaluated. The activities of 232 Th in vegetable, grains, salt, sugar and fish samples ranged from 0.13±0.02 to 1.49±0.32 Bq. kg -1 . The concentration of 238 U in these food-stuffs ranged from 0.07±0.01 to 0.95±0.26 Bq Kg -1 . The observed activity of 40 K ranged between 5.04±1.05 and 196.60±41.0 Bq Kg -1 . Caesium was not detected in any of the samples, Assessment of annual intake of these radionuclides has been made on the basis of the average annual intake of these food-stuffs by the population of Bangladesh.The annual effective dose equivalent due to ingestion of different naturally occurring radionuclides ( 232 Th, 238 U, and 40 K) by intake food-stuffs ranged from 0.2 to 113.62 μ Sv. y'-1. The annual effective doses observed in the present study for various types of food-stuffs were less than the ICRP-60 (1990) recommendation, which is 1 m Sv. y -1 for the members of the public. The result and knowledge of this study, would be helpful in making a yardstick comparing with which an appropriate radiation control limit may be imposed on food materials for public consumption in Bangladesh. 1 fig., 2 tables, 13 refs. (Author)

  13. [Evaluation of patient doses in interventional radiology].

    Science.gov (United States)

    Ropolo, R; Rampado, O; Isoardi, P; Gandini, G; Rabbia, C; Righi, D

    2001-01-01

    To verify the suitability of indicative quantities to evaluate the risk related to patient exposure, in abdominal and vascular interventional radiology, by the study of correlations between dosimetric quantities and other indicators. We performed in vivo measurements of entrance skin dose (ESD) and dose area product (DAP) during 48 procedures to evaluate the correlation among dosimetric quantities, and an estimation of spatial distribution of exposure and effective dose (E). To measure DAP we used a transmission ionization chamber and to evaluate ESD and its spatial distribution we used radiographic film packed in a single envelope and placed near the patient's skin. E was estimated by a calculation software using data from film digitalisation. From the data derived for measurements in 27 interventional procedures on 48 patients we obtained a DAP to E conversion factor of 0.15 mSv / Gy cm2, with an excellent correlation (r=.99). We also found a good correlation between DAP and exposure parameters such as fluoroscopy time and number of images. The greatest effective dose was evaluated for a multiple procedure in the hepatic region, with a DAP value of 425 Gy cm2. The greatest ESD was about 550 mGy. For groups of patients undergoing similar interventional procedures the correlation between ESD and DAP had conversion factors from 6 to 12 mGy Gy-1 cm-2. The evaluation of ESD and E by slow films represents a valid method for patient dosimetry in interventional radiology. The good correlation between DAP and fluoroscopy time and number of images confirm the suitability of these indicators as basic dosimetric information. All the ESD values found are lower than threshold doses for deterministic effects.

  14. Clinical pharmacokinetics of Icotinib, an anti-cancer drug: evaluation of dose proportionality, food effect, and tolerability in healthy subjects.

    Science.gov (United States)

    Liu, Dongyang; Jiang, Ji; Zhang, Li; Tan, Fenlai; Wang, Yingxiang; Zhang, Don; Hu, Pei

    2014-04-01

    Icotinib, an oral epidermal growth factor receptor tyrosine kinase inhibitor, has proved effectiveness in xenografted nude mice. Purpose of the present studies was to investigate tolerability and pharmacokinetics of Icotinib in healthy subjects for the first time, including dose proportionality, food effect, and tolerability. Two studies were conducted in total of 22 healthy subjects: a randomized, two-Latin-square crossover, dose proportional study (n = 12) and a randomized two-way crossover food-effect study (n = 10). Plasma concentration of Icotinib reached peak at a median Tmax of 0.75-3.5 h after single dose and then declined with a mean t1/2β of 6.02-7.83 h. Over the dose range of 100-600 mg, AUC values were proportional to dose and Cmax showed a slight saturation when dose increases. Only 0.2 % of the dose was excreted through kidney in unchanged Icotinib. After dosing 400 mg of Icotinib with high-fat and high-calorie meal, mean Cmax and AUC were significantly increased by 59 and 79 %, respectively. Three subjects experienced four adverse events (rash, increase in AST and ALT, and external injury). Rash and increased levels of AST and ALT were considered as drug-related. No serious adverse events were reported. The current work demonstrated that Icotinib was well tolerated in healthy male subjects (n = 22) over the dose range of 100-600 mg with or without food. Icotinib exposure, expressed in AUC, was proportionally increased with dose over the above dose range. Food intake significantly increased the absorption and exposure of Icotinib in healthy subjects.

  15. Late effects of low doses and dose rates

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1980-01-01

    This paper outlines the spectrum of problems and approaches used in work on the derivation of quantitative prognoses of late effects in man of low doses and dose rates. The origins of principal problems encountered in radiation risks assessments, definitions and explanations of useful quantities, methods of deriving risk factors from biological and epidemiological data, and concepts of risk evaluation and problems of acceptance are individually discussed

  16. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  17. A dose-finding, cross-over study to evaluate the effect of a Nestorone®/Estradiol transdermal gel delivery on ovulation suppression in normal ovulating women.

    Science.gov (United States)

    Brache, Vivian; Merkatz, Ruth; Kumar, Narender; Jesam, Cristian; Sussman, Heather; Hoskin, Elena; Roberts, Kevin; Alami, Mohcine; Taylor, Deshawn; Jorge, Aidelis; Croxatto, Horacio; Lorange, Ellen; Mishell, Daniel R; Sitruk-Ware, Regine

    2015-10-01

    This study aims to determine the lowest effective of three Nestorone (NES)/estradiol (E2) transdermal gel doses to ensure ovulation suppression in 90-95% of cycles. This was a randomized, open-label, three-treatment-period cross-over study to evaluate the effects of NES/E2 transdermal gel on ovulation inhibition, suppression of follicular growth and pharmacokinetic parameters. The doses were low (1.5 mg NES/0.5 mg E2), medium (3.0 mg NES/1.0 mg E2) and high (4.5 mg NES/1.5 mg E2). Participants applied gel daily to a fixed area on the abdomen for 21 consecutive days. They were interviewed regarding their experiences using the gel. Eighteen participants were randomized; 16 completed the study. Median NES C(max) values for low, medium and high dose groups at day 21 were 318.6 pmol/L, 783.0 pmol/L and 1063.8 pmol/L, respectively. Median maximum follicular diameter was higher with the lowest dose with 16.2 mm versus 10.0 and 10.4 mm with the medium and high doses, respectively. Among adherent participants, ovulation was inhibited in all dose groups, except for one participant in the medium dose (6.7%) that had luteal activity and an ultrasound image suggestive of a luteinized unruptured follicle. There were few reports of unscheduled bleeding, with more episodes reported for the lower dose. Adverse events were mild, and no skin irritation was reported from gel application. While all three doses blocked ovulation effectively and were evaluated as safe and acceptable, the medium dose was considered the lowest effective dose based on a more adequate suppression of follicular development. Further development of this novel contraceptive delivering NES and E2 is warranted and has potential for improved safety compared to ethinyl-estradiol-based methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Development of an effective dose coefficient database using a computational human phantom and Monte Carlo simulations to evaluate exposure dose for the usage of NORM-added consumer products.

    Science.gov (United States)

    Yoo, Do Hyeon; Shin, Wook-Geun; Lee, Jaekook; Yeom, Yeon Soo; Kim, Chan Hyeong; Chang, Byung-Uck; Min, Chul Hee

    2017-11-01

    After the Fukushima accident in Japan, the Korean Government implemented the "Act on Protective Action Guidelines Against Radiation in the Natural Environment" to regulate unnecessary radiation exposure to the public. However, despite the law which came into effect in July 2012, an appropriate method to evaluate the equivalent and effective doses from naturally occurring radioactive material (NORM) in consumer products is not available. The aim of the present study is to develop and validate an effective dose coefficient database enabling the simple and correct evaluation of the effective dose due to the usage of NORM-added consumer products. To construct the database, we used a skin source method with a computational human phantom and Monte Carlo (MC) simulation. For the validation, the effective dose was compared between the database using interpolation method and the original MC method. Our result showed a similar equivalent dose across the 26 organs and a corresponding average dose between the database and the MC calculations of database with sufficient accuracy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Radiobiological evaluation of the radiation dose as used in high-precision radiotherapy. Effect of prolonged delivery time and applicability of the linear-quadratic model

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Otsuka, Shinya; Iwata, Hiromitsu; Sugie, Chikao; Ogino, Hiroyuki; Tomita, Natsuo

    2012-01-01

    Since the dose delivery pattern in high-precision radiotherapy is different from that in conventional radiation, radiobiological assessment of the physical dose used in stereotactic irradiation and intensity-modulated radiotherapy has become necessary. In these treatments, the daily dose is usually given intermittently over a time longer than that used in conventional radiotherapy. During prolonged radiation delivery, sublethal damage repair takes place, leading to the decreased effect of radiation. This phenomenon is almost universarily observed in vitro. In in vivo tumors, however, this decrease in effect can be counterbalanced by rapid reoxygenation, which has been demonstrated in a laboratory study. Studies on reoxygenation in human tumors are warranted to better evaluate the influence of prolonged radiation delivery. Another issue related to radiosurgery and hypofractionated stereotactic radiotherapy is the mathematical model for dose evaluation and conversion. Many clinicians use the linear-quadratic (LQ) model and biologically effective dose (BED) to estimate the effects of various radiation schedules, but it has been suggested that the LQ model is not applicable to high doses per fraction. Recent experimental studies verified the inadequacy of the LQ model in converting hypofractionated doses into single doses. The LQ model overestimates the effect of high fractional doses of radiation. BED is particularly incorrect when it is used for tumor responses in vivo, since it does not take reoxygenation into account. For normal tissue responses, improved models have been proposed, but, for in vivo tumor responses, the currently available models are not satisfactory, and better ones should be proposed in future studies. (author)

  20. A dose error evaluation study for 4D dose calculations

    Science.gov (United States)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  1. DOZIM - evaluation dose code for nuclear accident

    International Nuclear Information System (INIS)

    Oprea, I.; Musat, D.; Ionita, I.

    2008-01-01

    During a nuclear accident an environmentally significant fission products release can happen. In that case it is not possible to determine precisely the air fission products concentration and, consequently, the estimated doses will be affected by certain errors. The stringent requirement to cope with a nuclear accident, even minor, imposes creation of a computation method for emergency dosimetric evaluations needed to compare the measurement data to certain reference levels, previously established. These comparisons will allow a qualified option regarding the necessary actions to diminish the accident effects. DOZIM code estimates the soil contamination and the irradiation doses produced either by radioactive plume or by soil contamination. Irradiations either on whole body or on certain organs, as well as internal contamination doses produced by isotope inhalation during radioactive plume crossing are taken into account. The calculus does not consider neither the internal contamination produced by contaminated food consumption, or that produced by radioactive deposits resuspension. The code is recommended for dose computation on the wind direction, at distances from 10 2 to 2 x 10 4 m. The DOZIM code was utilized for three different cases: - In air TRIGA-SSR fuel bundle destruction with different input data for fission products fractions released into the environment; - Chernobyl-like accident doses estimation; - Intervention areas determination for a hypothetical severe accident at Cernavoda Nuclear Power Plant. For the first case input data and results (for a 60 m emission height without iodine retention on active coal filters) are presented. To summarize, the DOZIM code conception allows the dose estimation for any nuclear accident. Fission products inventory, released fractions, emission conditions, atmospherical and geographical parameters are the input data. Dosimetric factors are included in the program. The program is in FORTRAN IV language and was run on

  2. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Habeeballa, B.; Osman, H.; Abdelaziz, I.; Sassi, S.A.; Sam, A.K.

    2015-01-01

    This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients’ doses were 0.46 mGy and 0.07 mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies

  3. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  4. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  5. Evaluation of patient dose during computed tomography angiography

    International Nuclear Information System (INIS)

    Dafalla, Elamam Yagoob Taha

    2015-10-01

    Computed tomography (CT), is an x-ray procedure that generates high quality cross sectional images of the body, and by comparison to other radiological diagnosis, CT is responsible for higher doses to patients. The evaluation of patient dose from computed tomography for pulmonary examinations the CT is responsible for higher doses to patients. The radiation dose was measured in three hospitals in Khartoum State during March 2015-October 2015 using different CT modalities. The radiation dose was higher at Alzytouna hospital than Daralelaj hospital and Alatebaa hospital was lowest. In this study, the mean effective dose for first hospital was 23.83±3.93 mSv and the mean effective dose for second hospital was 8.94±1.64 mSv and the mean effective dose for third hospital was 2.96±0.79. (author)

  6. Superficial dose evaluation of four dose calculation algorithms

    Science.gov (United States)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  7. A Retrospective Study Evaluating the Effect of Low Doses of Perineural Dexamethasone on Ropivacaine Brachial Plexus Peripheral Nerve Block Analgesic Duration.

    Science.gov (United States)

    Schnepper, Gregory D; Kightlinger, Benjamin I; Jiang, Yunyun; Wolf, Bethany J; Bolin, Eric D; Wilson, Sylvia H

    2017-09-23

    Examination of the effectiveness of perineural dexamethasone administered in very low and low doses on ropivacaine brachial plexus block duration. Retrospective evaluation of brachial plexus block duration in a large cohort of patients receiving peripheral nerve blocks with and without perineural dexamethasone in a prospectively collected quality assurance database. A single academic medical center. A total of 1,942 brachial plexus blocks placed over a 16-month period were reviewed. Demographics, nerve block location, and perineural dexamethasone utilization and dose were examined in relation to block duration. Perineural dexamethasone was examined as none (0 mg), very low dose (2 mg or less), and low dose (greater than 2 mg to 4 mg). Continuous catheter techniques, local anesthetics other than ropivacaine, and block locations with fewer than 15 subjects were excluded. Associations between block duration and predictors of interest were examined using multivariable regression models. A subgroup analysis of the impact of receiving dexamethasone on block duration within each block type was also conducted using a univariate linear regression approach. A total of 1,027 subjects were evaluated. More than 90% of brachial plexus blocks contained perineural dexamethasone (≤4 mg), with a median dose of 2 mg. Increased block duration was associated with receiving any dose of perineural dexamethasone (P block duration did not differ with very low- or low-dose perineural dexamethasone after controlling for other factors (P = 0.420). Perineural dexamethasone prolonged block duration compared with ropivacaine alone; however, duration was not greater with low-dose compared with very low-dose perineural dexamethasone. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Evaluation of the Effects of Integrated Management Weed Control on Corn Field by Using Reduced Dose of Foramsulfuron and Nicosulfuron Herbicides

    Directory of Open Access Journals (Sweden)

    M. Matinfar

    2011-09-01

    Full Text Available In order to evaluate the effects of integrated weed management on weed control by using reduced herbicide dose, a field experiment was conducted in 2010 in Qazvin. The experiment was conducted in randomized complete block design with 24 treatments and 4 replications. The treatments were: different planting patterns at three levels (single row, square double rows and zigzag double row  plantings and doses of  Nicosulfuron and Foramsulfuron application at four levels (1, 1/5, 2 and 2/5 liters per hectare, The results showed that among the different planting patterns, zigzag planting reduced weed populations and their dry weights significantly. Foramsulfuron herbicide could control weeds better than Nicosulfuron. Among the herbicide dosages, 2/5 litter dose per hectare highly reduced weed density its dry weight as compared to one litter dose.

  9. Plutonium dose-effect relationship

    International Nuclear Information System (INIS)

    Matsuoka, Osamu

    1976-01-01

    Dose in internal exposure to Pu was investigated, and dose-effect relationship was discussed. Dose-effect relationship in internal exposure was investigated by means of two methods, which were relationship between dose and its effect (relationship between μ Ci/Kg and its effect), and exposure dose and its effects (rad-effect), and merits and demerits of two methods were mentioned. Problems in a indication method such as mean dose were discussed with respect to the dose in skeleton, the liver and the lung. Pu-induced osteosarcoma in mice rats, and beagles was described, and differences in its induction between animals were discussed. Pulmonary neoplasma induced by 239 PuO 2 inhalation in beagles was reported, and description was made as to differences in induction of lung cancer between animals when Pu was inhaled and was taken into the lung. A theoretical and experimental study of a extrapolation of the results of the animal experiment using Pu to human cases is necessary. (Serizawa, K.)

  10. Intracavitary radiation treatment planning and dose evaluation

    International Nuclear Information System (INIS)

    Anderson, L.L.; Masterson, M.E.; Nori, D.

    1987-01-01

    Intracavitary radiation therapy with encapsulated radionuclide sources has generally involved, since the advent of afterloading techniques, inserting the sources in tubing previously positioned within a body cavity near the region to be treated. Because of the constraints on source locations relative to the target region, the functions of treatment planning and dose evaluation, usually clearly separable in interstitial brachytherapy, tend to merge in intracavitary therapy. Dose evaluation is typically performed for multiple source-strength configurations in the process of planning and thus may be regarded as complete when a particular configuration has been selected. The input data for each dose evaluation, of course, must include reliable dose distribution information for the source-applicator combinations used. Ultimately, the goal is to discover the source-strength configuration that results in the closest possible approach to the dose distribution desired

  11. Evaluation of the effect of multiple doses of lansoprazole on the pharmacokinetics and safety of ponatinib in healthy subjects.

    Science.gov (United States)

    Narasimhan, Narayana I; Dorer, David J; Davis, Jeffrey; Turner, Christopher D; Sonnichsen, Daryl

    2014-10-01

    In vitro studies have demonstrated that the aqueous solubility of the tyrosine kinase inhibitor ponatinib decreases as pH increases. The primary aim of this study was to assess the effects of the gastric proton pump inhibitor lansoprazole on the pharmacokinetics of ponatinib. The single-dose safety profile of ponatinib with and without coadministration of lansoprazole was also characterized. This was a phase I, open-label, non-randomized, two-period crossover study in 20 healthy subjects aged 18-55 years. Subjects received a single oral dose of ponatinib 45 mg alone on day 1, an oral dose of lansoprazole 60 mg on day 14, and ponatinib 45 mg plus lansoprazole 60 mg on day 15. Lansoprazole coadministration resulted in a 1-h increase in the time to maximum plasma concentration (t max) of ponatinib (6 vs. 5 h post-dose; P lansoprazole versus ponatinib alone (40.67 vs. 53.96 ng/mL). Importantly, lansoprazole did not decrease the overall ponatinib systemic exposure as assessed by the ponatinib area under the plasma concentration-time curve from time zero to infinity (AUC∞ 1,153 ng·h/mL for lansoprazole + ponatinib vs. 1,222 ng·h/mL for ponatinib alone). The safety profile was considered acceptable when ponatinib was administered alone or with lansoprazole. Although coadministration of lansoprazole led to a modest, albeit statistically significant, reduction in ponatinib C max, overall systemic exposure to ponatinib did not change. The findings suggest that no dose adjustment is necessary when ponatinib is administered with drugs that increase gastric pH.

  12. Standards, options and recommends for the external radiotherapy of patients reached by prostate carcinoma: evaluation of dose effect

    International Nuclear Information System (INIS)

    Pommier, P.; Fervers, B.; Villers, A.; Bataillard, A.

    2002-01-01

    The 'Standards, Options and Recommendations' (SOR) collaborative project was initiated in 1993 by the Federation of the French Cancer Centres (FNCLCC), with the 20 French Regional Cancer Centres (FNCCLCC), with the 20 French Regional Cancer Centres, several French public university and general hospitals, as well as private clinics and medical specialty societies. Its main objective is the development of serviceable clinical practice guidelines in order to improve the quality of health care and the outcome of cancer patients. The methodology is based on a literature review, followed by critical appraisal by a multidisciplinary group of experts. Draft guidelines for the radiotherapy of prostate cancer using the methodology developed by the Standards, Options and Recommendations project. The FNCLCC and the French Urology Association (AFU) designated the multidisciplinary group of experts. Available data were collected by a search of Medline and lists selected by experts in the group A first draft of the guidelines was written, they validated by independent reviewers. The main recommendations are: a minimal dose of 70 Gy; patients with intermediate prognosis are the ones who benefit most from the dose escalation effect over 74 Gy, provided they receive exclusive radiation therapy; whenever possible, patients should be included in controlled trials designed to assess the effects of dose escalation and hormonotherapy. (author)

  13. Dosimetry in Interventional Radiology - Effective Dose Estimation

    International Nuclear Information System (INIS)

    Miljanic, S.; Buls, N.; Clerinx, P.; Jarvinen, H.; Nikodemova, D.; Ranogajec-Komor, M; D'Errico, F.

    2008-01-01

    Interventional radiological procedures can lead to significant radiation doses to patients and to staff members. In order to evaluate the personal doses with respect to the regulatory dose limits, doses measured by dosimeters have to be converted to effective doses (E). Measurement of personal dose equivalent Hp(10) using a single unshielded dosimeter above the lead apron can lead to significant overestimation of the effective dose, while the measurement with dosimeter under the apron can lead to underestimation. To improve the accuracy, measurements with two dosimeters, one above and the other under the apron have been suggested ( d ouble dosimetry ) . The ICRP has recommended that interventional radiology departments develop a policy that staff should wear two dosimeters. The aim of this study was to review the double dosimetry algorithms for the calculation of effective dose in high dose interventional radiology procedures. The results will be used to develop general guidelines for personal dosimetry in interventional radiology procedures. This work has been carried out by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its 6th Framework Program.(author)

  14. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  15. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy

    International Nuclear Information System (INIS)

    Bahreyni Toossi, M.T.; Ghorbani, Mahdi; Akbari, Fatemah; Sabet, Leila S.; Mehrpouyan, Mohammad

    2016-01-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm 2 applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam’s energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  16. An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation

    International Nuclear Information System (INIS)

    Kim, Jung-Ha; Hill, Robin; Kuncic, Zdenka

    2012-01-01

    The Monte Carlo (MC) method has proven invaluable for radiation transport simulations to accurately determine radiation doses and is widely considered a reliable computational measure that can substitute a physical experiment where direct measurements are not possible or feasible. In the EGSnrc/BEAMnrc MC codes, there are several user-specified parameters and customized transport algorithms, which may affect the calculation results. In order to fully utilize the MC methods available in these codes, it is essential to understand all these options and to use them appropriately. In this study, the effects of the electron transport algorithms in EGSnrc/BEAMnrc, which are often a trade-off between calculation accuracy and efficiency, were investigated in the buildup region of a homogeneous water phantom and also in a heterogeneous phantom using the DOSRZnrc user code. The algorithms and parameters investigated include: boundary crossing algorithm (BCA), skin depth, electron step algorithm (ESA), global electron cutoff energy (ECUT) and electron production cutoff energy (AE). The variations in calculated buildup doses were found to be larger than 10% for different user-specified transport parameters. We found that using BCA = EXACT gave the best results in terms of accuracy and efficiency in calculating buildup doses using DOSRZnrc. In addition, using the ESA = PRESTA-I option was found to be the best way of reducing the total calculation time without losing accuracy in the results at high energies (few keV ∼ MeV). We also found that although choosing a higher ECUT/AE value in the beam modelling can dramatically improve computation efficiency, there is a significant trade-off in surface dose uncertainty. Our study demonstrates that a careful choice of user-specified transport parameters is required when conducting similar MC calculations. (note)

  17. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  18. Determination of radon concentration in drinking water resources of villages nearby Lalehzar fault and evaluation the annual effective dose

    International Nuclear Information System (INIS)

    Mohammad Malakootian; Zahra Darabi Fard; Mojtaba Rahimi

    2015-01-01

    The radon concentration has been measured in 44 drinking water resources, in villages nearby Lalehzar fault in winter 2014. Some samples showed a higher concentration of radon surpassing limit set by EPA. Further, a sample was taken from water distribution networks for these sources of water. Soluble radon concentration was measured by RAD7 device. Range radon concentration was 26.88 and 0.74 BqL -1 respectively. The maximum and minimum annual effective dose for adults was estimated at 52.7 and 2.29 µSvY -1 , respectively. Reducing radon from water before use is recommended to improve public health. (author)

  19. Evaluation of the Effect of Different Doses of Low Energy Shock Wave Therapy on the Erectile Function of Streptozotocin (STZ-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Zhong-Cheng Xin

    2013-05-01

    Full Text Available To investigate the therapeutic effect of different doses of low energy shock wave therapy (LESWT on the erectile dysfunction (ED in streptozotocin (STZ induced diabetic rats. SD rats (n = 75 were randomly divided into 5 groups (normal control, diabetic control, 3 different dose LESWT treated diabetic groups. Diabetic rats were induced by intra-peritoneal injection of STZ (60 mg/kg and rats with fasting blood glucose ≥ 300 mg/dL were selected as diabetic models. Twelve weeks later, different doses of LESWT (100, 200 and 300 shocks each time treatment on penises were used to treat ED (7.33 MPa, 2 shocks/s three times a week for two weeks. The erectile function was evaluated by intracavernous pressure (ICP after 1 week washout period. Then the penises were harvested for histological study. The results showed LESWT could significantly improve the erectile function of diabetic rats, increase smooth muscle and endothelial contents, up-regulate the expression of α-SMA, vWF, nNOS and VEGF, and down- regulate the expression of RAGE in corpus cavernosum. The therapeutic effect might relate to treatment dose positively, and the maximal therapeutic effect was noted in the LESWT300 group. Consequently, 300 shocks each time might be the ideal LESWT dose for diabetic ED treatment.

  20. Radiation. Doses, effect, risk

    International Nuclear Information System (INIS)

    Vapirev, E.; Todorov, P.

    1994-12-01

    This book outlines in a popular form the topic of ionizing radiation impacts on living organisms. It contains data gathered by ICRP for a period of 35 years. The essential dosimetry terms and units are presented. Natural and artificial sources of ionizing radiation are described. Possible biological radiation effects and diseases as a consequence of external and internal irradiation at normal and accidental conditions are considered. An assessment of genetic risk for human populations is presented and the concept of 'acceptable risk' is discussed

  1. A rational quantitative approach to determine the best dosing regimen for a target therapeutic effect: a unified formalism for antibiotic evaluation.

    Science.gov (United States)

    Li, Jun; Nekka, Fahima

    2013-02-21

    The determination of an optimal dosing regimen is a critical step to enhance the drug efficacy and avoid toxicity. Rational dosing recommendations based on mathematical considerations are increasingly being adopted in the process of drug development and use. In this paper, we propose a quantitative approach to evaluate the efficacy of antibiotic agents. By integrating both pharmacokinetic (PK) and pharmacodynamic (PD) information, this approach gives rise to a unified formalism able to measure the cause-effect of dosing regimens. This new pharmaco-metric allows to cover a whole range of antibiotics, including the two well known concentration and time dependent classes, through the introduction of the Hill-dependency concept. As a direct fallout, our formalism opens a new path toward the bioequivalence evaluation in terms of PK and PD, which associates the in vivo drug concentration and the in vitro drug effect. Using this new approach, we succeeded to reveal unexpected, but relevant behaviors of drug performance when different drug regimens and drug classes are considered. Of particular notice, we found that the doses required to reach the same therapeutic effect, when scheduled differently, exhibit completely different tendencies for concentration and time dependent drugs. Moreover, we theoretically confirmed the previous experimental results of the superiority of the once daily regimen of aminoglycosides. The proposed methodology is appealing for its computational features and can easily be applicable to design fair clinical protocols or rationalize prescription decisions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Evaluations of gonad and fetal doses for diagnostic radiology.

    Science.gov (United States)

    Tung, C J; Tsai, H Y

    1999-07-01

    A national survey of patient doses for diagnostic radiology was planned in the Republic of China. We performed a pilot study for this survey to develop a protocol of the dose assessments. Entrance skin doses and organ (including ovary, testicle and uterus) doses were measured by thermoluminescent dosimeters and calculated by means of Monte Carlo simulations for several diagnostic procedures. We derived a formula and used the RadComp software for the computation of entrance skin doses. This formula involves several factors, such as kVp, mAs, the focus-to-skin-distance and aluminum filtration. RadComp software was applied to obtain free-air entrance exposures which were converted to entrance skin doses by considering the backscattering radiation from the body. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom for several diagnostic examinations. Genetically significant doses were calculated from ovary and testicle doses for the evaluation of hereditary effects. Embryo/fetal doses were determined from the uterine doses by considering the increase in uterus size with gestational age. We found that the patient doses studied in this work were all below the reference doses recommended by the National Radiological Protection Board of the U.K.

  3. SU-E-T-409: Evaluation of Tissue Composition Effect On Dose Distribution in Radiotherapy with 6 MV Photon Beam of a Medical Linac

    Energy Technology Data Exchange (ETDEWEB)

    Ghorbani, M; Tabatabaei, Z; Noghreiyan, A Vejdani [Mashhad University of Medical Sciences, Mashhad (Iran, Islamic Republic of); Meigooni, A Soleimani [Comprehensive Cancer Center of Nevada, Las Vegas, NV (United States)

    2015-06-15

    Purpose: The aim of this study is to evaluate soft tissue composition effect on dose distribution for various soft tissues and various depths in radiotherapy with 6 MV photon beam of a medical linac. Methods: A phantom and Siemens Primus linear accelerator were simulated using MCNPX Monte Carlo code. In a homogeneous cubic phantom, six types of soft tissue and three types of tissue-equivalent materials were defined separately. The soft tissues were muscle (skeletal), adipose tissue, blood (whole), breast tissue, soft tissue (9-component) and soft tissue (4-component). The tissue-equivalent materials included: water, A-150 tissue-equivalent plastic and perspex. Photon dose relative to dose in 9-component soft tissue at various depths on the beam’s central axis was determined for the 6 MV photon beam. The relative dose was also calculated and compared for various MCNPX tallies including,F8, F6 and,F4. Results: The results of the relative photon dose in various materials relative to dose in 9-component soft tissue and using different tallies are reported in the form of tabulated data. Minor differences between dose distributions in various soft tissues and tissue-equivalent materials were observed. The results from F6 and F4 were practically the same but different with,F8 tally. Conclusion: Based on the calculations performed, the differences in dose distributions in various soft tissues and tissue-equivalent materials are minor but they could be corrected in radiotherapy calculations to upgrade the accuracy of the dosimetric calculations.

  4. Gamma dose effects valuation on micro computing components; Evaluation des effets de la dose gamma sur les composants micro-informatiques

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, F

    1996-12-31

    Robotics in hostile environment raises the problem of micro computing components resistance with gamma radiation cumulated dose. The current aim is to reach a dose of 3000 grays with industrial components. A methodology and an instrumentation adapted to test this type of components have been developed. The aim of this work is to present the advantages and disadvantages bound to the use of industrial components in the presence of gamma radiation. After an analysis of the criteria allowing to justify the technological choices, the different steps which characterize the selection and the assessment methodology used are explained. The irradiation and measures means now operational are mentioned. Moreover, the supply aspects of the chosen components for the design of an industrialized system is taken into account. These selection and assessment components contribute to the development and design of computers for civil nuclear robotics. (O.M.). 7 refs.

  5. Dose evaluation of narrow-beam

    International Nuclear Information System (INIS)

    Goto, Shinichi

    1999-01-01

    Reliability of the dose from the narrow photon beam becomes more important since the single high-dose rate radiosurgery becoming popular. The dose evaluation for the optimal dose is difficult due to absence of lateral electronic equilibrium. Data necessary for treatment regimen are TMR (tissue maximum ratio), OCR (off center ratio) and S c,p (total scatter factor). The narrow-beam was 10 MV X-ray from Varian Clinac 2100C equipped with cylindrical Fischer collimator CBI system. Detection was performed by Kodak XV-2 film, a PTW natural diamond detector M60003, Scanditronics silicon detector EDD-5 or Fujitec micro-chamber FDC-9.4C. Phantoms were the water equivalent one (PTW, RW3), water one (PTW, MP3 system) and Wellhofer WP600 system. Factors above were actually measured to reveal that in the dose evaluation of narrow photon beam, TMR should be measured by micro-chamber, OCR, by film, and S c,p , by the two. The use of diamond detector was recommended for more precise measurement and evaluation of the dose. The importance of water phantom in the radiosurgery system was also shown. (K.H.)

  6. Effect of chronic low dose natural radiation in human peripheral blood mononuclear cells: Evaluation of DNA damage and repair using the alkaline comet assay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, P.R. Vivek, E-mail: prvkumar06@gmail.com [Low Level Radiation Research Laboratory, Radiation Biology and Health Sciences Division, Bio-Science Group, Bhabha Atomic Research Centre, IRE Campus, Beach Road, Kollam 691 001, Kerala (India); Seshadri, M. [Low Level Radiation Research Section, Radiation Biology and Health Sciences Division, Bio-Science Group, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Jaikrishan, G. [Low Level Radiation Research Laboratory, Radiation Biology and Health Sciences Division, Bio-Science Group, Bhabha Atomic Research Centre, IRE Campus, Beach Road, Kollam 691 001, Kerala (India); Das, Birajalaxmi [Low Level Radiation Research Section, Radiation Biology and Health Sciences Division, Bio-Science Group, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India)

    2015-05-15

    Highlights: • Effect of chronic low dose natural radiation in radio adaptive response studied. • PBMCs of subjects from NLNRA and HLNRA were challenged with gamma radiation. • DNA damage and repair in PBMCs was compared using the alkaline comet assay. • Significant reduction in DNA damage in subjects of high dose group from HLNRA noted. • Probable induction of an in vivo radio adaptive response in subjects from HLNRA. - Abstract: This study investigates whether peripheral blood mononuclear cells (PBMCs) from inhabitants of Kerala in southwest India, exposed to chronic low dose natural radiation in vivo (>1 mSv year{sup −1}), respond with a radioadaptive response to a challenging dose of gamma radiation. Toward this goal, PBMCs isolated from 77 subjects from high-level natural radiation areas (HLNRA) and 37 subjects from a nearby normal level natural radiation area (NLNRA) were challenged with 2 Gy and 4 Gy gamma radiation. Subjects from HLNRA were classified based on the mean annual effective dose received, into low dose group (LDG) and high dose group (HDG) with mean annual effective doses of 2.69 mSv (N = 43, range 1.07 mSv year{sup −1} to 5.55 mSv year{sup −1}) and 9.62 mSv (N = 34, range 6.07 mSv year{sup −1} to17.41 mSv year{sup −1}), respectively. DNA strand breaks and repair kinetics (at 7 min, 15 min and 30 min after 4 Gy) were evaluated using the alkaline single cell gel electrophoresis (comet) assay. Initial levels of DNA strand breaks observed after either a 2 Gy or a 4 Gy challenging dose were significantly lower in subjects of the HDG from HLNRA compared to subjects of NLNRA (2 Gy, P = 0.01; 4 Gy, P = 0.02) and LDG (2 Gy P = 0.01; 4 Gy, P = 0.05). Subjects of HDG from HLNRA showed enhanced rejoining of DNA strand breaks (HDG/NLNRA, P = 0.06) during the early stage of repair (within 7 min). However at later times a similar rate of rejoining of strand breaks was observed across the groups (HDG, LDG and NLNRA). Preliminary results from

  7. Determination of Radon Level in Drinking Water in Mehriz Villages and Evaluation the Annual Effective Absorbed Dose

    Directory of Open Access Journals (Sweden)

    Mohammad Malakootian

    2015-03-01

    Results: Radon concentrations of samples ranged from 0.187 BqL-1 to 14.8 BqL-1.These results were related to samples No.12 and 9 and also to aqueducts of Tang-e-chenar and Malekabad village respectively. Based on the amount of radon in the sample, the lowest annual effective absorbed dose through drinking water or breathing(In an environment where water was used was 0.0005msv/y and the maximum amount was 0.04msv/y. Conclusion: Apart from samples No.9 and 16 that were elated to the aqueduct of Malekabad village and a private well in Dare Miankoohvillagehaving48 persons as total population, Radon concentrations of other samples used by people of Mehriz villages as drinking water was low and less than permitted limit set by the Environmental Protection Agency of United States of America.

  8. Dose evaluation and protection of cosmic radiation

    International Nuclear Information System (INIS)

    Iwai, Satoshi; Takagi, Toshiharu

    2004-01-01

    This paper explained the effects of cosmic radiation on aircraft crews and astronauts, as well as related regulations. International Commission on Radiological Protection (ICRP) recommends the practice of radiation exposure management for the handling/storage of radon and materials containing natural radioactive substances, as well as for boarding jet aircraft and space flight. Common aircraft crew members are not subject to radiation exposure management in the USA and Japan. In the EU, the limit value is 6 mSv per year, and for the crew group exceeding this value, it is recommended to keep records containing appropriate medical examination results. Pregnant female crewmembers are required to keep an abdominal surface dose within 1 mSv. For astronauts, ICRP is in the stage of thinking about exposure management. In the USA, National Council on Radiation Protection and Measurement has set dose limits for 30 days, 1 year, and lifetime, and recommends lifetime effective dose limits against carcinogenic risk for each gender and age group. This is the setting of the dose limits so that the risk of carcinogenesis, to which space radiation exposure is considered to contribute, will reach 3%. For cosmic radiation environments at spacecraft inside and aircraft altitude, radiation doses can be calculated for astronauts and crew members, using the calculation methods for effective dose and dose equivalent for tissue. (A.O.)

  9. Evaluation of the genotoxic effects of chronic low-dose ionizing radiation exposure on nuclear medicine workers

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Ali [Department of Nuclear Medicine, Faculty of Medicine, Medical School, Ataturk University, Erzurum (Turkey)], E-mail: alibabam2001@yahoo.com; Tatar, Abdulgani; Oztas, Sitki [Department of Genetics, Faculty of Medicine, Ataturk University, 25240 Erzurum (Turkey); Seven, Bedri; Varoglu, Erhan [Department of Nuclear Medicine, Faculty of Medicine, Medical School, Ataturk University, Erzurum (Turkey); Yesilyurt, Ahmet [Department of Genetics, Faculty of Medicine, Ataturk University, 25240 Erzurum (Turkey); Ayan, Arif Kursad [Department of Nuclear Medicine, Faculty of Medicine, Medical School, Ataturk University, Erzurum (Turkey)

    2009-07-15

    Introduction: Nuclear medicine workers are occupationally exposed to chronic ionizing radiation. It is known that ionizing radiation may have damaging effects on chromosomes. In the present study, we investigated the genotoxic effects of ionizing radiation on nuclear medicine workers. We used two different indicators of genotoxicity methods: sister chromatid exchange (SCE) and micronucleus (MN). Methods: The present research was carried out using 21 nuclear medicine workers (11 females and 10 males) during two periods: during normal working conditions and after a 1-month vacation. The radiation dose varied from 1.20 to 48.56 mSv, which accumulated during the occupational exposure time between two vacations. Peripheral blood samples were taken from each subject for two distinct lymphocyte cultures (SCE and MN) in each period. Results: In nearly all subjects, SCE values increased significantly during radiation exposure compared to the postvacation period (P<.05). Similarly, MN frequencies in most of the subjects increased significantly during radiation exposure compared to the postvacation period (P<.05). Conclusions: This study revealed that both SCE and MN frequencies in most of the subjects were significantly higher during exposure to ionizing radiation than after a 1-month vacation period. However, this genotoxic effect was reversible in most of the subjects.

  10. Evaluation of the genotoxic effects of chronic low-dose ionizing radiation exposure on nuclear medicine workers

    International Nuclear Information System (INIS)

    Sahin, Ali; Tatar, Abdulgani; Oztas, Sitki; Seven, Bedri; Varoglu, Erhan; Yesilyurt, Ahmet; Ayan, Arif Kursad

    2009-01-01

    Introduction: Nuclear medicine workers are occupationally exposed to chronic ionizing radiation. It is known that ionizing radiation may have damaging effects on chromosomes. In the present study, we investigated the genotoxic effects of ionizing radiation on nuclear medicine workers. We used two different indicators of genotoxicity methods: sister chromatid exchange (SCE) and micronucleus (MN). Methods: The present research was carried out using 21 nuclear medicine workers (11 females and 10 males) during two periods: during normal working conditions and after a 1-month vacation. The radiation dose varied from 1.20 to 48.56 mSv, which accumulated during the occupational exposure time between two vacations. Peripheral blood samples were taken from each subject for two distinct lymphocyte cultures (SCE and MN) in each period. Results: In nearly all subjects, SCE values increased significantly during radiation exposure compared to the postvacation period (P<.05). Similarly, MN frequencies in most of the subjects increased significantly during radiation exposure compared to the postvacation period (P<.05). Conclusions: This study revealed that both SCE and MN frequencies in most of the subjects were significantly higher during exposure to ionizing radiation than after a 1-month vacation period. However, this genotoxic effect was reversible in most of the subjects.

  11. Evaluation of two-dimensional bolus effect of immobilization/support devices on skin doses: A radiochromic EBT film dosimetry study in phantom

    International Nuclear Information System (INIS)

    Chiu-Tsao, Sou-Tung; Chan, Maria F.

    2010-01-01

    Purpose: In this study, the authors have quantified the two-dimensional (2D) perspective of skin dose increase using EBT film dosimetry in phantom in the presence of patient immobilization devices during conventional and IMRT treatments. Methods: For 6 MV conventional photon field, the authors evaluated and quantified the 2D bolus effect on skin doses for six different common patient immobilization/support devices, including carbon fiber grid with Mylar sheet, Orfit carbon fiber base plate, balsa wood board, Styrofoam, perforated AquaPlast sheet, and alpha-cradle. For 6 and 15 MV IMRT fields, a stack of two film layers positioned above a solid phantom was exposed at the air interface or in the presence of a patient alpha-cradle. All the films were scanned and the pixel values were converted to doses based on an established calibration curve. The authors determined the 2D skin dose distributions, isodose curves, and cross-sectional profiles at the surface layers with or without the immobilization/support device. The authors also generated and compared the dose area histograms (DAHs) and dose area products from the 2D skin dose distributions. Results: In contrast with 20% relative dose [(RD) dose relative to d max on central axis] at 0.0153 cm in the film layer for 6 MV 10x10 cm 2 open field, the average RDs at the same depth in the film layer were 71%, 69%, 55%, and 57% for Orfit, balsa wood, Styrofoam, and alpha-cradle, respectively. At the same depth, the RDs were 54% under a strut and 26% between neighboring struts of a carbon fiber grid with Mylar sheet, and between 34% and 56% for stretched perforated AquaPlast sheet. In the presence of the alpha-cradle for the 6 MV (15 MV) IMRT fields, the hot spot doses at the effective measurement depths of 0.0153 and 0.0459 cm were 140% and 150% (83% and 89%), respectively, of the isocenter dose. The enhancement factor was defined as the ratio of a given DAH parameter (minimum dose received in a given area) with and without

  12. Fetal dose evaluation during breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Antypas, Christos; Sandilos, Panagiotis; Kouvaris, John; Balafouta, Ersi; Karinou, Eleftheria; Kollaros, Nikos; Vlahos, Lambros

    1998-01-01

    Purpose: The aim of the work was to estimate the radiation dose delivered to the fetus in a pregnant patient irradiated for breast cancer. Methods and Materials: A 45-year woman was treated for left breast cancer using a 6 MV photon beam with two isocentric opposing tangential unwedged fields. Daily dose was 2.3 Gy at 95% isodose line given by two fields/day, 5 days/week. A total dose of 46 Gy was given in 20 fractions over a 4-week period. Pregnancy confirmed during the second therapeutic week. Treatment lasted between the second and sixth gestation week. Radiation dose to fetus was estimated from in vivo and phantom measurements using thermoluminescence dosimeters and an ionization chamber. In vivo measurements were performed by inserting either a catheter with TL dosimeters or ionization chamber into the patient's rectum. Phantom measurements were performed by simulating the treatment conditions on an anthropomorphic phantom. Results: TLD measurements (in vivo and phantom) revealed fetal dose to be 0.085% of the tumor dose, corresponding to a cumulative fetal dose of 3.9 cGy for the entire treatment of 46 Gy. Chamber measurements (in vivo and phantom) revealed a fetal dose less than the TLD result: 0.079 and 0.083% of the tumor dose corresponding to cumulative fetal dose of 3.6 cGy and 3.8 cGy for in vivo and phantom measurement, respectively. Conclusions: It was concluded that the cumulative dose delivered to the unshielded fetus was 3.9 cGy for a 46 Gy total tumor dose. The estimated fetal dose is low compared to the total tumor dose given due to the early stage of pregnancy, the large distance between fundus-radiation field, and the fact that no wedges and/or lead blocks were used. No deterministic biological effects of radiation on the live-born embryo are expected. The lifetime risk for radiation-induced fatal cancer is higher than the normal incidence, but is considered as inconsequential

  13. Low doses effects and gamma radiations low dose rates

    International Nuclear Information System (INIS)

    Averbeck, D.

    1999-01-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  14. Dose evaluation for the public around the Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Takeishi, Minoru; Furuta, Sadaaki; Miyabe, Kenjiro; Shinohara, Kunihiko

    2007-01-01

    The dose evaluations for the public around the Tokai Reprocessing Plant (TRP) have been carried out by using the mathematical models, because the effects on the environmental radiation due to the operation of the TRP are too small to separate from the background level. The models were developed by the site-specific investigations of the environment and reviewed in several times based on the latest scientific knowledge. The maximum annual effective dose through the whole period of the operation of the TRP was evaluated as 1.4 μSv with the data of the discharge monitoring and the meteorological observation in 1992. The evaluated doses revealed to be kept as far below the annual dose limit for the public as 1 mSv. (author)

  15. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  16. Radiation dose of CT coronary angiography in clinical practice: Objective evaluation of strategies for dose optimization

    International Nuclear Information System (INIS)

    Yerramasu, Ajay; Venuraju, Shreenidhi; Atwal, Satvir; Goodman, Dennis; Lipkin, David; Lahiri, Avijit

    2012-01-01

    Background: CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. Objectives: To estimate the radiation dose of CTCA in clinical practice and evaluate the effect of dose-saving algorithms on radiation dose and image quality. Methods: Effective radiation dose was measured from the dose-length product in 616 consecutive patients (mean age 58 ± 12 years; 70% males) who underwent clinically indicated CTCA at our institution over 1 year. Image quality was assessed subjectively using a 4-point scale and objectively by measuring the signal- and contrast-to-noise ratios in the coronary arteries. Multivariate linear regression analysis was used to identify factors independently associated with radiation dose. Results: Mean effective radiation dose of CTCA was 6.6 ± 3.3 mSv. Radiation dose was significantly reduced by dose saving algorithms such as 100 kV imaging (−47%; 95% CI, −44% to −50%), prospective gating (−35%; 95% CI, −29% to −40%) and ECG controlled tube current modulation (−23%; 95% CI, −9% to −34%). None of the dose saving algorithms were associated with a significant reduction in mean image quality or the frequency of diagnostic scans (P = non-significant for all comparisons). Conclusion: Careful application of radiation-dose saving algorithms in appropriately selected patients can reduce the radiation burden of CTCA significantly, without compromising the image quality.

  17. Some aspects of dose evaluation, 3

    International Nuclear Information System (INIS)

    Yoshida, Yoshikazu

    1979-01-01

    This paper describes methods of calculating the radioiodine releases and resultant doses in the ''Guide for calculation of doses to man from routine releases of effluents from light-water-cooled nuclear power plants for evaluating compliance with dose objectives around a site of LWRs'' by the Japan Nuclear Safety Commission. Examples of dose calculation in the design stage of plants and releases of radioiodine from operating plants are also given. The thyroid dose objective from radioiodine in reactor effluents was determined to be 15 mrem per year by the AEC of Japan in 1975. In the guide, models and parameters are given as most realistic on the basis of current knowledge and experience; in cases involving unknown factors these are on conservative side. Calculations of annual average releases of gaseous and liquid effluents are made using the models and parameters established through operational experiences of the LWR plants. Annual thyroid doses are calculated from inhalation and ingestion of leafy vegetable and cow's milk for gaseous effluents and ingestion of marine food for liquid effluents. In calculation of the thyroid dose, fw = 0.2 is used instead of = 0.3 in ICRP publ. 2 for ingestion of foods excluding seaweed and the specific activity method for ingestion of foods including seaweed. It is because Japanese take foods with much stable iodine. Calculated annual releases of 131 I in gaseous effluents of typical BWR (1100 MWe) and PWR (800 MWe) are about 2 Ci and 0.7 Ci per year per plant and the annual thyroid doses are about 4 mrem and 9 mrem per year, respectively. Actually, however, releases of 131 I in gaseous effluents from the operating LWR plants are about less than one tenth of the above figures. (author)

  18. Effective dose in abdominal digital radiography: Patient factor

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Sung; Koo, Hyun Jung; Park, Jung Hoon; Cho, Young Chul; Do, Kyung Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of); Yang, Hyung Jin [Dept. of Medical Physics, Korea University, Seoul (Korea, Republic of)

    2017-08-15

    To identify independent patient factors associated with an increased radiation dose, and to evaluate the effect of patient position on the effective dose in abdominal digital radiography. We retrospectively evaluated the effective dose for abdominal digital radiography in 222 patients. The patients were divided into two groups based on the cut-off dose value of 0.311 mSv (the upper third quartile of dose distribution): group A (n = 166) and group B (n = 56). Through logistic regression, independent factors associated with a larger effective dose were identified. The effect of patient position on the effective dose was evaluated using a paired t-test. High body mass index (BMI) (≥ 23 kg/m2), presence of ascites, and spinal metallic instrumentation were significantly associated with a larger effective dose. Multivariate logistic regression analysis revealed that high BMI [odds ratio (OR), 25.201; p < 0.001] and ascites (OR, 25.132; p < 0.001) were significantly associated with a larger effective dose. The effective dose was significantly lesser (22.6%) in the supine position than in the standing position (p < 0.001). High BMI and ascites were independent factors associated with a larger effective dose in abdominal digital radiography. Significant dose reduction in patients with these factors may be achieved by placing the patient in the supine position during abdominal digital radiography.

  19. Evaluation of the enter surface dose, dose in organ and E effective dose, received by personnel and patients in studies of endoscopic retrograde cholangeopancreatography in the General Hospital of Mexico

    International Nuclear Information System (INIS)

    Reyes, S.; Gama T, G.; Beristain, M.; Espino, H.

    2006-01-01

    The ESD for patient and personal is measured: gastroenterologuist endoscopist G1, A1 Assistant and A2 instrumentist that carried out 22 independent therapeutic procedures of CPRE, in a fluoroscopy equipment Toshiba trademark with tube under the table, operated in automatic exposure mode, CAE to average tensions of 80 kVp. The measurement is carried out with film dosemeters of double emulsion Kodak Type 2 trademark, calibrated in terms of H * for the energy of the 137 Cs, first it is determined the films sensitivity like function of the optical density DO, and second the ESD for the effective energy of the radiation beam (50 keV), in three different points from the dosemeter (C, D and H). The films was placed for the personnel in: right hand, front (eye), thyroid and thorax (under D and out F of the lead apron); in the case of the patient three positions were used: thorax, hepatic region and pelvis. The mean values of the ESD and it standard deviation SD in mGy units are determined by: study, personnel, film position in doctor and patient, dosemeter measurement point. The calculated doses in organ are also determined for the patient in the thorax region, liverwort and pelvis its are agreement with the NRPB SR 262 report. Finally the H E and E for medical personnel and patients are estimated demonstrating that its are not exceeded the annual dose limits for the case of the OEP. In the case of the the OEP have for the D thorax an ESD max = 0.04 mGy that one corresponds an H E = 0.02 and E = 0.01 mSv. (Author)

  20. Vancomycin Utilization Evaluation: Are We Dosing Appropriately?

    Directory of Open Access Journals (Sweden)

    Ladan Ayazkhoo

    2015-10-01

    Full Text Available Background: Inappropriate use of vancomycin not only increase health care costs but also contribute to the emergence of resistant organisms. Higher trough serum vancomycin concentrations (>10mg/L has been recommended for avoidance of development of resistance. We aim to compare the administered dose with recommended doses based on guideline-recommended weight-based dosing.Methods: In a cross sectional study, all patients who received vancomycin between July and October 2013, in infectious disease, internal medicine wards and emergency department of a teaching hospital in Tehran, Iran were entered to the study. Indication of vancomycin and necessary data for dose calculation including height and serum creatinine were recorded. Prescribed doses were compared with recommended doses in guidelines and calculated Glomerular filtration rate (GFR for each patient.Results: One hundred and four patients (45 females and 59 males recruited in the study. Our results indicated that, from all administered doses of vancomycin, 64.4% and 88.8% differs significantly (more than 20% based on American Pharmacist Association (AphA vancomycin monograph and guideline-recommended, weight-based vancomycin dosing (for adults, respectively.Conclusion: Underdosing of vancomycin is a major risk factor for developing resistance of gram positive organisms to this glycopeptide. Our results showed that more than half of patients receiving vancomycin are in the risk of low drug levels based on guidelines. So, having a comprehensive plan for the proper use of this drug especially designing effective internal guidelines can prevent emergence of resistance to vancomycin in future.

  1. Evaluation of lens dose in medulloblastoma radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, F.L.; Vilela, E.C.; Sousa, S.A; Lima, F.F. de

    2007-01-01

    The improvement of the applied radiotherapy techniques in the cranial-spinal therapy, which is used in the cases of medulloblastoma, aims the reduction of the risks of future damages in enclosed critical agencies in the irradiation fields. This work aims to evaluate the lens doses due two common techniques used in medulloblastoma radiotherapy. For this, thermoluminescent dosimeters, previously calibrated, were located in an anthropomorphic phantom (ALDERSON - RANDON Laboratory), in the tumor and lens positions. The employed techniques were as following: (1) angled fields technique and (2) half-beam block technique. The phantom was irradiated five times in each technique with two lateral opposed fields in the brain with a total prescribed dose of 1.5 Gy, followed of two posterior spinal fields with the same prescribed dose, using a 6MV accelerator. The results showed that the doses in the first technique were 0.10 +- 0,04 Gy and, in second one, 0.09 +- 0,02 Gy. It was observed that, independent of the employed technique, the lens doses practically are the same. (author)

  2. Evaluation of doses in gastrointestinal fluoroscopy

    International Nuclear Information System (INIS)

    Canevaro, Lucia Viviana

    1995-04-01

    This work aims at the development of a methodology to measure radiation doses to patients and professionals (radiologists) in fluoroscopic gastrointestinal tract examinations. Also, it aims at the assessment of the performance of this type of medical x-ray equipment, from the radiation protection point of view at the Department of Radiology of the Hospital Universitario Clementino Fraga Filho (Universidade Federal de Rio de Janeiro). This work was developed in order to identify the actual status and to set base lines as a reference for a quality control program. The calibration procedures of thermoluminescent dosimeters for radiodiagnosis quality beams are discussed and described here as well as its application in dose measurements, for patients and radiologists. The performance of two types of x-ray equipment (fluorescent screen and image intensifier) usually used to perform this examinations was evaluated through appropriate tests. Radiation protection features are also considered. Dose to radiologists at unprotected regions and to patients at several sample points were measured. A comparison of the measured doses given by both types of equipment was made. After further analysis, the necessity to look for methods that reduce unnecessary doses became evident. The high values obtained in some procedures using fluorescent screen make the use of this type of equipment unacceptable. With these results, we consider that Health Care authorities have the responsibility of replacing all fluorescent screen equipment and of establishing standards, and raising awareness the responsible staff. (author)

  3. Organ dose and effective dose with the EOS scanner in spine deformity surgery

    DEFF Research Database (Denmark)

    Heide Pedersen, Peter; Petersen, Asger Greval; Eiskjær, Søren Peter

    2016-01-01

    Organ dose and effective dose with the EOS scanner in spine deformity surgery. A study on anthropomorphic phantoms describing patient radiation exposure in full spine examinations. Authors: Peter Heide Pedersen, Asger Greval Petersen, Søren Peter Eiskjær. Background: Ionizing radiation potentially...... quality images while at the same time reducing radiation dose. At our institution we use the EOS for pre- and postoperative full spine examinations. Purpose: The purpose of the study is to make first time organ dose and effective dose evaluations with micro-dose settings in full spine examinations. Our...... hypothesis is that organ dose and effective doses can be reduced 5-10 times compared to standard settings, without too high image-quality trade off, resulting in a theoretical reduction of radiation induced cancer. Methods: Patient dosimetry is performed on anthropomorphic child phantoms, representing a 5...

  4. Pharmacokinetic evaluation of pamidronate after oral administration: a study on dose proportionality, absolute bioavailability, and effect of repeated administration

    DEFF Research Database (Denmark)

    Hyldstrup, Lars; Flesch, G; Hauffe, S A

    1993-01-01

    30 minutes at constant infusion rate. Repeated peroral doses (75 and 150 mg) were administered to 12 females (aged 51-70 years) for 10 consecutive days. Urinary excretion of pamidronate after peroral and i.v. administration was used for estimation of pamidronate absorption. Renal excretion...... of pamidronate ranged from 0.01% to 0.35% of dose, with mean values of 0.11, 0.16, and 0.18% for 75, 150, and 300 mg, respectively. After i.v. infusion, the renal excretion of pamidronate was 26-53% of the dose, lower than for other bisphosphonates. The absolute bioavailability was 0.31% (range 0.08-0.7%) after...

  5. Measurement and evaluation of internal dose

    International Nuclear Information System (INIS)

    Lee, Tae Young; Chang, S. Y.; Lee, J. I.; Song, M. Y.

    2006-01-01

    This report describes the contents and results for implementation of internal radiation monitoring programme, measurement of uranium present in lung by lung counter and assessment of committed effective dose for radiation workers of the KNFC. The aim of radiation protection was achieved by implementing this activity

  6. Critical commentary on dose-rate evaluations

    International Nuclear Information System (INIS)

    Dowdy, E.J.; Malenfant, R.E.; Plassmann, E.A.

    1984-01-01

    Survivors of Hiroshima and Nagasaki present a unique problem in dosimetry: the effects of radiation exposure may be inferred although the exposure itself is unknown. Experience with a replica of Little Boy demonstrates the difficulties of measuring dose rates, the problems of comparing measurements with calculations, and the inadequacy of the conventional standards that are used to calibrate dosimeters

  7. Evaluation of the effect of radiation levels and dose rates in irradiation of murine fibroblasts used as a feeder layer in the culture of human keratinocytes

    International Nuclear Information System (INIS)

    Yoshito, Daniele; Almeida, Tiago L.; Santin, Stefany Plumeri; Somessari, Elizabeth S.R.; Silveira, Carlos G. da; Mathor, Monica B.; Altran, Silvana C.; Isaac, Cesar

    2009-01-01

    In 1975, Rheinwald and Green published an effective methodology for obtaining and cultivating human keratinocytes. This methodology consisted of seeding keratinocytes onto a feeder layer composed of lineage 3T3 murine fibroblasts, the proliferation rate of which is then controlled through the action of ionizing radiation. The presence of the feeder layer encourages the development of keratinocyte colonies and their propagation in similar cultures, becoming possible several clinical applications as skin substitutes or wound dressings in situations such as post burn extensive skin loss and other skin disorders. However, good development of these keratinocytes depends on a high quality feeder layer among other factors. In the present work, we evaluated the relationship between radiation levels and dose rates applied to fibroblasts used in construction of feeder layers and the radiation effect on keratinocytes colonies forming efficiency. Results indicate 3T3 lineage murine fibroblasts irradiated with doses varying between 60 and 100 Gy can be used as a feeder layer immediately after irradiation or storage of the irradiated cells in suspension at 4 g C for 24 hours with similar results. The exception is when the irradiation dose rate is 2.75 Gyh -1 ; in this case, results suggested that the fibroblasts should be used immediately after irradiation. (author)

  8. Design and development of an anthropomorphic phantom equipped with detectors in order to evaluate the effective dose E at workplaces: feasibility study

    International Nuclear Information System (INIS)

    Furstoss, Ch.

    2006-11-01

    My PhD study aims to determine the feasibility to design and develop, for photon fields, an anthropomorphic phantom equipped with detectors in order to evaluate the effective dose E at workplaces. First of all, the energy losses within the organs are calculated using the M.C.N.P.X. Monte Carlo code, in order to determine the detection positions within the different organs. Then, to decrease the number of detection positions, the organ contribution to the effective dose is studied. Finally, the characteristics of the detectors to insert and the characteristics of the phantom to use are deduced. The results show that 24 or 23 detection positions, according to the wT values (publication 60 or new recommendations of the ICRP), give a E estimation with an uncertainty of ±15 % from 50 keV to 4 MeV. Moreover, the interest of such an instrument is underlined while comparing the E estimation by the personal dose equivalent Hp to the E estimation by the instrumented phantom when the phantom is irradiated by point sources (worker in front of a glove box for example). Last, after the detector and phantom characteristic determination, two types of detectors and one type of phantom are selected. However, for the detectors mainly, developments are necessary. Follow up this study, the characterization and the adaptation of the detectors to the project would be interesting. Furthermore, the study to mixed photon-neutrons would be required the needs of the radiological protection community. (author)

  9. Effect of radiation dose level on accuracy and precision of manual size measurements in chest tomosynthesis evaluated using simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Soederman, Christina; Allansdotter Johnsson, Aase; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus

    2016-01-01

    The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intra-observer variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. (authors)

  10. Notes on the effect of dose uncertainty

    International Nuclear Information System (INIS)

    Morris, M.D.

    1987-01-01

    The apparent dose-response relationship between amount of exposure to acute radiation and level of mortality in humans is affected by uncertainties in the dose values. It is apparent that one of the greatest concerns regarding the human data from Hiroshima and Nagasaki is the unexpectedly shallow slope of the dose response curve. This may be partially explained by uncertainty in the dose estimates. Some potential effects of dose uncertainty on the apparent dose-response relationship are demonstrated

  11. Using Population Dose to Evaluate Community-level Health Initiatives.

    Science.gov (United States)

    Harner, Lisa T; Kuo, Elena S; Cheadle, Allen; Rauzon, Suzanne; Schwartz, Pamela M; Parnell, Barbara; Kelly, Cheryl; Solomon, Loel

    2018-05-01

    Successful community-level health initiatives require implementing an effective portfolio of strategies and understanding their impact on population health. These factors are complicated by the heterogeneity of overlapping multicomponent strategies and availability of population-level data that align with the initiatives. To address these complexities, the population dose methodology was developed for planning and evaluating multicomponent community initiatives. Building on the population dose methodology previously developed, this paper operationalizes dose estimates of one initiative targeting youth physical activity as part of the Kaiser Permanente Community Health Initiative, a multicomponent community-level obesity prevention initiative. The technical details needed to operationalize the population dose method are explained, and the use of population dose as an interim proxy for population-level survey data is introduced. The alignment of the estimated impact from strategy-level data analysis using the dose methodology and the data from the population-level survey suggest that dose is useful for conducting real-time evaluation of multiple heterogeneous strategies, and as a viable proxy for existing population-level surveys when robust strategy-level evaluation data are collected. This article is part of a supplement entitled Building Thriving Communities Through Comprehensive Community Health Initiatives, which is sponsored by Kaiser Permanente, Community Health. Copyright © 2018 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  12. Patient Doses and Risk Evaluation in Bone Mineral Densitometry

    International Nuclear Information System (INIS)

    Angelucci, M.; Borio, R.; Chiocchini, S.; Degli Esposti, P.; Dipilato, A.C.; Policani, G.

    1999-01-01

    The aim of this work was to evaluate the equipment dose to the organs and tissues and the effective dose of patients undergoing the most frequent examinations carried out in bone mineral densitometry (BMD): lumbar spine and femur. Experimental measurements of absorbed doses on a Rando phantom, allow comparison of the performances of three different photon emitter facilities. The comparison of the entrance and exit doses measured on a Rando phantom and on 50 female non-obese patients show that entrance doses on Rando can be used as 'diagnostic reference levels' for patients. A quantitative estimate of the stochastic risk due to BMD procedures was made: the results obtained show that the stochastic risk is very low and that the BMD is, at present, the most confirmed procedure for osteoporosis diagnosis and management. (author)

  13. Integral dose and evaluation of irradiated tissue volume

    International Nuclear Information System (INIS)

    Sivachenko, T.P.; Kalina, V.K.; Belous, A.K.; Gaevskij, V.I.

    1984-01-01

    Two parameters having potentialities of radiotherapy planning improvement are under consideration. One of these two parameters in an integral dose. An efficiency of application of special tables for integral dose estimation is noted. These tables were developed by the Kiev Physician Improvement Institute and the Cybernetics Institute of the Ukrainian SSR Academy of Science. The meaning of the term of ''irradiated tissue volume'' is specified, and the method of calculation of the irradiated tissue effective mass is considered. It is possible to evaluate with higher accuracy tolerance doses taking into account the irradiated mass

  14. Prospective study evaluating the radiosensitizing effect of reduced doses of temozolomide in the treatment of Egyptian patients with glioblastoma multiforme

    Directory of Open Access Journals (Sweden)

    Gaber M

    2013-10-01

    Full Text Available May Gaber, Hanan Selim, Tamer El-NahasDepartment of Clinical Oncology, Cairo University, Cairo, EgyptPurpose: In view of the documented toxicity of continuous daily radiosensitizer doses of temozolomide concomitant with radiation in the treatment of glioblastoma multiforme, we aimed to compare it with a different schedule of abbreviated radiosensitizer dosing.Patients and methods: This was a randomized prospective study comparing toxicity and survival in 60 Egyptian patients with glioblastoma multiforme. Patients in arm I received temozolomide at a dose of 75 mg/m2 daily with radiotherapy for 42 days, starting 4 weeks after surgery and reaching to a total radiation dose of 60 Gy/30 Fractions/6 weeks, while patients in arm II received temozolomide at a dose of 75 mg/m2 concomitantly with the same radiotherapy schedule daily in the first and last weeks of the same radiotherapy program.Results: Common grade 1–2 adverse events were malaise in 28 patients (46.7%, followed by alopecia (40% and nausea (26.7%. Grade 3–4 convulsion and decreased level of consciousness was seen in only four patients who were all from arm I. The median progression-free survival (PFS for the entire study population was 10.6 months (95% confidence interval [CI] 7.3–14, and PFS at 12 months was 32%. The median PFS in arm I was 8.8 months (95% CI 5.9–11.7 and in arm II 11.5 months (95% CI 8.9–14.2, and PFS at 12 months for both arms was 32% and 30% respectively (P=0.571. The median overall survival (OS of the whole group of patients was 14.2 months (95% CI 13–15.5, and OS was 70% at 12 months and 25% at 18 months. The median OS for patients in arm I was 12.3 months (95% CI 7.7–16.9, whereas in arm II it was 14.3 months (95% CI 14–14.7 (P=0.83.Conclusion: Reduced radiosensitizer dosing of temozolomide concomitant with radiotherapy in glioblastoma multiforme exhibited comparable efficacy with a classic continuous daily schedule, though with better tolerability

  15. Evaluation of the radioprotective effect of turmeric extract and vitamin E in mice exposed to therapeutic dose of radioiodine

    International Nuclear Information System (INIS)

    Bhartiya, Uma S.; Raut, Yogita S.; Joseph, Lebana J.; Hawaldar, Rohini W.; Rao, Badanidiyoor S.

    2008-01-01

    The aim of this study was to evaluate the radioprotective effect of turmeric extract (40 mg/kg body weight) and vitamin E (α - tocopherol acetate, 400 IU/kg body weight) supplementation on lipid peroxidation, reduced glutathione and antioxidant defense enzymes in various organs like liver, kidney and salivary glands at 24 h in adult Swiss mice. 131 Iodine exposure significantly increased lipid peroxidation in kidney and salivary glands in comparison to control animals. Pre supplementation with turmeric extract for 15 days showed significant lowering of lipid peroxidation in kidney. On the other hand vitamin E pre supplementation showed marked reduction in lipid peroxidation in salivary glands. Reduced glutathione levels decreased significantly in liver after radiation exposure. However, pre supplementation with turmeric extract and vitamin E did not improve glutathione levels in liver. In conclusion we have observed differential radioprotective effect of turmeric extract and vitamin E in kidney and salivary glands. However, Vitamin E seems to offer better radioprotection for salivary glands which is known to be the major site of cellular destruction after radioiodine therapy in patients. (author)

  16. Evaluation of radiation doses from MDCT-imaging in otolaryngology

    International Nuclear Information System (INIS)

    Yamauchi-Kawaura, C.; Fujii, K.; Aoyama, T.; Yamauchi, M.; Koyama, S.

    2009-01-01

    The purpose of this study was to clarify patient doses in the current otolaryngological multi-detector row computed tomography (MDCT) examinations. Patient doses were measured with an in-phantom dosimetry system which was composed of 48 photodiode dosemeters embedded within an anthropomorphic phantom. Organ and effective doses were evaluated according to the International Commission on Radiological Protection Publication 103. In neck CT, doses for salivary glands and for thyroid were high, 7.6-29.9 and 13.4-60.3 mGy, respectively. In sinus CT, brain and lens doses were high, 7.6-24.6 and 10.6-32.0 mGy, respectively, and in inner ear CT, lens dose was 8.0-35.3 mGy. Effective doses were 1.8-6.6 mSv in neck CT, 0.5-0.9 mSv in sinus CT and 0.3-0.6 mSv in inner ear CT. The present dose data would be used to estimate radiation risks for patients undergoing otolaryngological MDCT examinations. (authors)

  17. Evaluation of the Effect of a Preoperative Single Dose of Gabapentin on Emergence Agitation in Patients Undergoing Breast Cancer Surgery

    Directory of Open Access Journals (Sweden)

    Simin Azemati

    2013-10-01

    Full Text Available Background: Emergence agitation is a transient confusional state that usuallyoccurs within 10 to 30 minutes of recovery from general anesthesia. It may lead to seriousconsequences and increasing hospital costs. This study evaluates the effect of gabapentinon emergence agitation in patients undergoing breast cancer surgery.Methods: This randomized, double blind controlled trial enrolled 100 femalepatients with American Society of Anesthesiologists' classifications I and II who werecandidates for breast cancer surgery. Patients were randomly assigned into two groups(n=50 that received either oral gabapentin 600 mg or placebo. Induction andmaintenance of anesthesia were similar in both groups. At the end of surgery, patient'sagitation score, pain score, and presence of nausea or vomiting were reported. In theward, the presence of headache or dizziness was checked during the first 8 h. Mann-Whitney test was used for comparison of agitation and pain scores between two groups.Chi-square test was used for comparing occurrence of nausea, vomiting and qualitative.The qualitative demographic variable and t-test compared quantitative demographicvariables.Results: There was a significantly lower incidence of emergence agitation in thegabapentin group before (P<0.001 and after (P=0.029 extubation. There weresignificantly lower mean agitation scores before (P<001 and after (P=0.006 extubationand in the pain score (P=0.005 in the gabapentin group. The need for remifentanilinfusion (P<0.05 during surgery was significantly lower in the gabapentin groupcompared with the placebo group. Occurrence of nausea and vomiting and gabapentinside effects that included headache or dizziness did not significantly differ between twogroups (P=0.126, P=1, P=0.629 respectively.Conclusion: Gabapentin not only decreased postoperative pain but also effectivelyreduced emergence agitation without any significant side effects in patients undergoingbreast cancer surgery.

  18. Dose evaluation from multiple detector outputs using convex optimisation

    International Nuclear Information System (INIS)

    Hashimoto, M.; Iimoto, T.; Kosako, T.

    2011-01-01

    A dose evaluation using multiple radiation detectors can be improved by the convex optimisation method. It enables flexible dose evaluation corresponding to the actual radiation energy spectrum. An application to the neutron ambient dose equivalent evaluation is investigated using a mixed-gas proportional counter. The convex derives the certain neutron ambient dose with certain width corresponding to the true neutron energy spectrum. The range of the evaluated dose is comparable to the error of conventional neutron dose measurement equipments. An application to the neutron individual dose equivalent measurement is also investigated. Convexes of particular dosemeter combinations evaluate the individual dose equivalent better than the dose evaluation of a single dosemeter. The combinations of dosemeters with high orthogonality of their response characteristics tend to provide a good suitability for dose evaluation. (authors)

  19. LUDEP: A Lung Dose Evaluation Program

    International Nuclear Information System (INIS)

    Birchall, A.; Bailey, M.R.; James, A.C.

    1990-06-01

    A Task Group of the ICRP is currently reviewing its dosimetric model for the respiratory tract with the aim of producing a more comprehensive and realistic model which can be used both for dosimetry and bioassay purposes. This in turn requires deposition, clearance, and dosimetry to be treated in a more detailed manner in than in the current model. In order to examine the practical application and radiological implications of the proposed model, a microcomputer program has been developed in a modular form so that changes can be easily included as the model develops. LUDEP (Lung Dose Evaluation Program) is a user-friendly menu-driven program which can be operated on any IBM-compatible PC. It enables the user to calculate (a) doses to each region of the respiratory tract and all other body organs, and (b) excretion rates and retention curves for bioassay purposes. 11 refs., 4 figs., 6 tabs

  20. Evaluation of the Cerebral State Index in Cats under Isoflurane Anaesthesia: Dose-Effect Relationship and Prediction of Clinical Signs

    Directory of Open Access Journals (Sweden)

    Joana R. Sousa

    2014-01-01

    Full Text Available The performance of the cerebral state index (CSI in reflecting different levels of isoflurane anaesthesia was evaluated in ten cats subjected to four end-tidal isoflurane concentrations (EtIso, each maintained for 15 minutes (0.8%, 1.2%, 1.6%, or 2.0% EtIso. The CSI, hemodynamic data, ocular reflexes, and eye position were recorded for each EtIso concentration. Pharmacodynamic analysis of CSI with EtIso was performed, as well as prediction probability analysis with a clinical scale based on the eye reflexes. The CSI values showed great variability. Between all parameters, burst suppression ratio showed the better fitting with the sigmoidal concentration-effect model (R2=0.93 followed by CSI (R2=0.82 and electromyographic activity (R2=0.79. EtIso was the variable with better prediction of the clinical scale of anaesthesia (prediction probability value of 0.94. Although the CSI values decrease with increasing isoflurane concentrations, the huge variability in CSI values may be a strong limitation for its use in cats and it seems to be no better than EtIso as a predictor of clinical signs.

  1. Evaluation of the effect of various parameters on the amount of radiation dose received by family members after 131-I therapy

    International Nuclear Information System (INIS)

    Sarkar, S.; Dehghanpour, M.; Saghari, M.; Ghiasinezhad, M.

    2001-01-01

    The main concern with respect to discharge of patients from hospital after 131-I therapy is contamination of their surroundings and exposure of people who are in close contact with them. In this study, we evaluated absorbed dose received by home mates of these patients within one week of discharge from hospital. This study was based on 100 patients (23 patients with thyroid cancer together with 70 members of their families and 2 hyperthyroid patients plus 5 of their family members). Measurements were performed by TLD. Patients were discharged from hospital if the dose rate from a meter distance of their thyroid was below 20 μSv/hr (ICRP-60). The hospitalization period for those patients with thyroid cancer varied between 2-3 days (depending on the amount of radioactivity received). Hyperthyroid patients were treated as outpatients. Our data indicate that although hyperthyroid patients received much less activity in comparison to those with thyroid cancer, but due to the slow iodine discharge rate from their bodies, they radiated more to their surroundings. For patients with thyroid cancer, when the given activity increased from 100 mCi to 150 mCi, the average dose absorbed by their family members increased by a factor of 3. The duration of hospitalization as well as the amount of activity given to the patients have a significant effect on the amount of radiation dose received by the family members. In a group of patients who received 100 mCi of 131-I, the average radiation dose received by the family members of those patients who were hospitalized for 2 days were 1.5 times more than of those patients who were hospitalized for 3 days, whereas following therapy with 150 mCi of 131-Iodine, the average radiation dose received by the family members of those patients who were hospitalized for 2 days were about 6.5 times more than that of those who were hospitalized for 3 days. The size of the patient's house and the time that family spends with the patient at house are

  2. Evaluating the Effect of Electron-Beam Irradiation on Linguatula serrata Destroy Isolated from Animal Products and Determining its Effective Dose

    Directory of Open Access Journals (Sweden)

    S Khalatbari-limaki

    2015-11-01

    Full Text Available Abstract Introduction: Foodborne parasitic diseases are considered common in most parts of the world, which can cause significant health problems. Linguatula serrata is a zoonotic parasite causing human linguatulosis due to consumption of raw and semi-cooked animal offal infected with nymphs of this parasite. Therefore, the main objective of this study was to determine the effect of Electron beam irradiation on death of the Linguatula serrata nymphs isolated from animal products. Methods: Linguatula serrata nymphs were irradiated with E-beam irradiation of 1, 2, 3 and 5 kGy doses 15 nymphs were classified into three groups of 5 for each dose. Death time of the nymphs was recorded by examining their movement under a stereomicroscope and then was compared with that of the control group stored at 4 °C. In order to analyze the study data, T-test and ANOVA were utilized setting the significance level at 0.05. Results: The comparison between treatment and control groups demonstrated a statistically significant difference in death time of the nymphs (P 0.05. Moreover, there was a statistically significant difference between the doses of 1, 2 and 3 kGy with dose of 5 kGy (P 0.05 in regard with their lethality speed. The results showed that minimum destruction dose of Linguatula serrata nymphs was 1 kGy and 5 KGy , resulted in a more rapidly death within the nymphs. Conclusion: Regarding the high sensitivity of Linguatula serrata nymphs to E-beam irradiation, this method can be used to enhance the safety of animal products in future.

  3. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  4. Gamma dose rate effect on JFET transistors

    International Nuclear Information System (INIS)

    Assaf, J.

    2011-04-01

    The effect of Gamma dose rate on JFET transistors is presented. The irradiation was accomplished at the following available dose rates: 1, 2.38, 5, 10 , 17 and 19 kGy/h at a constant dose of 600 kGy. A non proportional relationship between the noise and dose rate in the medium range (between 2.38 and 5 kGy/h) was observed. While in the low and high ranges, the noise was proportional to the dose rate as the case of the dose effect. This may be explained as follows: the obtained result is considered as the yield of a competition between many reactions and events which are dependent on the dose rate. At a given values of that events parameters, a proportional or a non proportional dose rate effects are generated. No dependence effects between the dose rate and thermal annealing recovery after irradiation was observed . (author)

  5. We can do better than effective dose for estimating or comparing low-dose radiation risks

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    The effective dose concept was designed to compare the generic risks of exposure to different radiation fields. More commonly these days, it is used to estimate or compare radiation-induced cancer risks. For various reasons, effective dose represents flawed science: for instance, the tissue-specific weighting factors used to calculate effective dose are a subjective mix of different endpoints; and the marked and differing age and gender dependencies for different health detriment endpoints are not taken into account. This paper suggests that effective dose could be replaced with a new quantity, ‘effective risk’, which, like effective dose, is a weighted sum of equivalent doses to different tissues. Unlike effective dose, where the tissue-dependent weighting factors are a set of generic, subjective committee-defined numbers, the weighting factors for effective risk are simply evaluated tissue-specific lifetime cancer risks per unit equivalent dose. Effective risk, which has the potential to be age and gender specific if desired, would perform the same comparative role as effective dose, be just as easy to estimate, be less prone to misuse, be more directly understandable, and would be based on solid science. An added major advantage is that it gives the users some feel for the actual numerical values of the radiation risks they are trying to control.

  6. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  7. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  8. Effective dose to radon considering people's activities

    International Nuclear Information System (INIS)

    Shimo, M.; Seki, K.; Kikuchi, I.

    1992-01-01

    The tidal volume was estimated for evaluating the effective dose due to radon concentration in the atmosphere. In this study regional population was separated to vocation and non-vocation. The occupancy time and the breathing rate for both vocation and non-vocation groups were estimated, and the annual tidal volume for both groups were calculated. Human actions were separated to 18 activities in the process for estimating the breathing rate. It was clear that the breathing rate depended on human activity and that the human activity changed with its age, so the breathing rate varied with age. Finally the effective doses due to radon and radon progeny indoors and outdoors were evaluated. The maximum annual effective dose was estimated to be 1.2 mSv, minimum 0.2 mSv, and mean 0.51 mSv for vocation. For non-vocation, the male maximum value 0.43 mSv was obtained at the 16 age and the minimum 0.12 mSv at the 70 age, whereas female maximum 0.26 mSv was obtained at the 12 age and the minimum 0.11 mSv at the 70 age. In addition in this study objective areas are Aichi, Gifu, and Mie prefectures for vocation and only Aichi prefecture for non-vocation. (author)

  9. Evaluation of the occupational dose in hemodynamic procedures

    International Nuclear Information System (INIS)

    Silva, Amanda J. da; Fernandes, Ivani M.; Sordi, Gian Maria A.A.; Carneiro, Janete C. Gaburo

    2010-01-01

    The purpose of this study was to evaluate the dose received by health professionals in a hemodynamic service. It was necessary to know the profile of these professional, to carry out a survey the occupational external doses during the years 2000 to 2009 and to evaluate the distribution of the effective dose from the special procedures guided by fluoroscopy. A self-applied questionnaire was used to delineate the profile of health professionals, taking into account variables such as gender, age, individual monitoring time, number of jobs and tasks performed in the sector. In addition, it was performed an examination of the external individual monitoring doses from the records of the institution. The sample was composed of 35 professionals, 11 males and 24 females, with mean age of (43.0 +- 10.4) years. The average monitoring time of individuals analyzed within the institution was (11.3 +- 9.1) years, considering the period before the study. The minimum record dose level was 0.2 mSv and the maximum dose was 22.7 mSv. Doctors and nursing assistants were the professionals more exposed to radiation, due probably remaining closer to the examination table and X-ray tube during the interventional procedure. (author)

  10. Improvement of dose evaluation method for employees at severe accident

    International Nuclear Information System (INIS)

    Onda, Takashi; Yoshida, Yoshitaka; Kudo, Seiichi; Nishimura, Kazuya

    2003-01-01

    It is expected that the selection of access routes for employees who engage in emergency work at a severe accident in a nuclear power plant makes a difference in their radiation dose values. In order to examine how much difference arises in the dose by the selection of the access routes, in the case of a severe accident in a pressurized water reactor plant, we improved the method to obtain the dose for employees and expanded the analyzing system. By the expansion of the system and the improvement of the method, we have realized the followings: (1) in the whole plant area, the dose evaluation is possible, (2) the efficiency of calculation is increased by the reduction of the number of radiation sources, etc, and (3) the function is improved by introduction of the sky shine calculation into the highest floor, etc. The improved system clarifies the followings: (1) the doses change by selected access routes, and this system can give the difference in the doses quantitatively, and (2) in order to suppress the dose, it is effective to choose the most adequate access route for the employees. (author)

  11. ACCEPTABILITY EVALUATION FOR USING ICRP TISSUE WEIGHTING FACTORS TO CALCULATE EFFECTIVE DOSE VALUE FOR SEPARATE GENDER-AGE GROUPS OF RUSSIAN FEDERATION

    Directory of Open Access Journals (Sweden)

    L. V. Repin

    2013-01-01

    Full Text Available An article describes radiation risk factors for several gender-age population groups according to Russian statistical and medical-demographic data, evaluates the lethality rate for separate nosologic forms of malignant neoplasms based on Russian cancer registries according to the method of the International Agency for Cancer Research. Relative damage factors are calculated for the gender-age groups under consideration. The tissue weighting factors recommended by ICRP to calculate effective doses are compared with relative damage factors calculated by ICRP for the nominal population and with similar factors calculated in this work for separate population cohorts in theRussian Federation. The significance of differences and the feasibility of using tissue weighting factors adapted for the Russian population in assessing population risks in cohorts of different gender-age compositions have been assessed.

  12. Effects of dose reduction on multi-detector computed tomographic images in evaluating the maxilla and mandible for pre-surgical implant planning: a cadaveric study.

    Science.gov (United States)

    Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro

    2010-08-01

    To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.

  13. Bayesian estimation of dose rate effectiveness

    International Nuclear Information System (INIS)

    Arnish, J.J.; Groer, P.G.

    2000-01-01

    A Bayesian statistical method was used to quantify the effectiveness of high dose rate 137 Cs gamma radiation at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice. The Bayesian approach considers both the temporal and dose dependence of radiation carcinogenesis and total mortality. This paper provides the first direct estimation of dose rate effectiveness using Bayesian statistics. This statistical approach provides a quantitative description of the uncertainty of the factor characterising the dose rate in terms of a probability density function. The results show that a fixed dose from 137 Cs gamma radiation delivered at a high dose rate is more effective at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice than the same dose delivered at a low dose rate. (author)

  14. Evaluation of 1cm dose equivalent rate using a NaI(Tl) scintilation spectrometer

    International Nuclear Information System (INIS)

    Matsuda, Hideharu

    1990-01-01

    A method for evaluating 1 cm dose equivalent rates from a pulse height distribution obtained by a 76.2mmφ spherical NaI(Tl) scintillation spectrometer was described. Weak leakage radiation from nuclear facilities were also measured and dose equivalent conversion factor and effective energy of leakage radiation were evaluated from 1 cm dose equivalent rate and exposure rate. (author)

  15. Effects of small radiation doses

    International Nuclear Information System (INIS)

    Fuchs, G.

    1986-01-01

    The term 'small radiation dosis' means doses of about (1 rem), fractions of one rem as well as doses of a few rem. Doses like these are encountered in various practical fields, e.g. in X-ray diagnosis, in the environment and in radiation protection rules. The knowledge about small doses is derived from the same two forces, on which the radiobiology of human beings nearly is based: interpretation of the Hiroshima and Nagasaki data, as well as the experience from radiotherapy. Careful interpretation of Hiroshima dates do not provide any evidence that small doses can induce cancer, fetal malformations or genetic damage. Yet in radiotherapy of various diseases, e.g. inflammations, doses of about 1 Gy (100 rad) do no harm to the patients. According to a widespread hypothesis even very small doses may induce some types of radiation damage ('no threshold'). Nevertheless an alternative view is justified. At present no decision can be made between these two alternatives, but the usefullness of radiology is definitely better established than any damage calculated by theories or extrapolations. Based on experience any exaggerated fear of radiations can be met. (author)

  16. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  17. Cytogenetic effects of low-dose radiation

    International Nuclear Information System (INIS)

    Metalli, P.

    1983-01-01

    The effects of ionizing radiation on chromosomes have been known for several decades and dose-effect relationships are also fairly well established in the mid- and high-dose and dose-rate range for chromosomes of mammalian cells. In the range of low doses and dose rates of different types of radiation few data are available for direct analysis of the dose-effect relationships, and extrapolation from high to low doses is still the unavoidable approach in many cases of interest for risk assessment. A review is presented of the data actually available and of the attempts that have been made to obtain possible generalizations. Attention is focused on some specific chromosomal anomalies experimentally induced by radiation (such as reciprocal translocations and aneuploidies in germinal cells) and on their relevance for the human situation. (author)

  18. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  19. The concept of the effective dose

    International Nuclear Information System (INIS)

    Jacobi, W.

    1975-01-01

    Irradiation of the human body by external or internal sources leads mostly to a simultaneous exposure of several organs. However, so far no clear and consistent recommendations for the combination of organ doses and the assessment of an exposure limit under such irradiation conditions are available. Following a proposal described in ICRP-publication 14 one possible concept for the combination of organ doses is discussed in this paper. This concept is based on the assumption that at low doses the total radiation detriment to the exposed person is given by the sum of radiation detriments to the single organs. Taking into account a linear dose-risk relationship, the sum of weighted organ doses leads to the definition of an 'Effective Dose'. The applicability and consequences of this 'Effective Dose Concept' are discussed especially with regard to the assessment of the maximum permissible intake of radionuclides into the human body and the combination of external and internal exposure. (orig.) [de

  20. The EFFECT trial: evaluating exacerbations, biomarkers, and safety outcomes with two dose levels of fluticasone propionate/formoterol in COPD

    Directory of Open Access Journals (Sweden)

    Papi A

    2015-11-01

    Full Text Available Alberto Papi,1 Paul W Jones,2 Prashant S Dalvi,3 Kirsten McAulay,4 Tammy McIver,5 Sanjeeva Dissanayake3 1Department of Internal and CardioRespiratory Medicine, Research Centre on Asthma and COPD, University of Ferrara, Ferrara, Italy; 2Institute for Infection and Immunity, St George’s, University of London, London, UK; 3Medical Science – Respiratory, 4Medical Operations, 5Data Management and Statistics, Mundipharma Research Ltd, Cambridge, UK Abstract: Inhaled corticosteroid/long-acting β2-agonist combination therapy is recommended in chronic obstructive pulmonary disease (COPD patients at high risk of exacerbations. The EFFECT (Efficacy of Fluticasone propionate/FormotErol in COPD Treatment trial is a Phase III, 52-week, randomized, double-blind study to evaluate the efficacy and safety of two doses of fluticasone propionate/formoterol compared to formoterol monotherapy in COPD patients with FEV1 ≤50% predicted and a history of exacerbations. The primary endpoint is the annualized rate of moderate and severe exacerbations. Secondary endpoints include pre-dose FEV1, EXACT-PRO (EXAcerbations of Chronic pulmonary disease Tool – Patient-Reported Outcome-defined exacerbations, St George’s Respiratory Questionnaire for COPD, COPD Assessment Test, and EXACT-Respiratory Symptoms total score. Lung-specific biomarkers (surfactant protein D and CC chemokine ligand-18 will be measured in a subset of patients to explore their relationship to other clinical indices in COPD and their predictive utility. Pneumonia will be diagnosed per criteria defined by the British Thoracic Society community acquired pneumonia guideline, primarily by radiological confirmation and, additionally, using clinical criteria when a chest radiograph cannot be obtained. Serial measurements of serum potassium, vital signs and electrocardiograms, 24-hour Holter monitoring, and 24-hour urinary cortisol measurement will be performed in a subset of patients in addition to

  1. Collaborative work to evaluate toxicity on male reproductive organs by repeated dose studies in rats 22). Effects of 2- and 4-week administration of theobromine on the testis.

    Science.gov (United States)

    Funabashi, H; Fujioka, M; Kohchi, M; Tateishi, Y; Matsuoka, N

    2000-10-01

    The effects of theobromine, a xanthine derivative, on the testis were compared between rats dosed for 2 and 4 weeks to determine whether a 2-week dosing period is long enough to detect toxicity. Theobromine was administered orally to male Sprague-Dawley rats at dose levels of 250 and 500 mg/kg for 2 weeks starting at the age of 6 or 8 weeks, and for 4 weeks from the age of 6 weeks. Histopathological examination of reproductive organs revealed toxic findings in the testis at 500 mg/kg after 2 weeks of dosing at both ages, and at 250 and 500 mg/kg after 4 weeks of dosing. The primary findings were degeneration/necrosis and desquamation of spermatids and spermatocytes, vacuolization of seminiferous tubules, and multinucleated giant cell formation. These findings were present mainly in stages I-VI and XII-XIV. From these results, it is concluded that the toxic effects of theobromine on the testis can be detected by repeated dosing for 2 weeks as well as for 4 weeks.

  2. Experimental evaluation of a MOSFET dosimeter for proton dose measurements

    International Nuclear Information System (INIS)

    Kohno, Ryosuke; Nishio, Teiji; Miyagishi, Tomoko; Hirano, Eriko; Hotta, Kenji; Kawashima, Mitsuhiko; Ogino, Takashi

    2006-01-01

    The metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry. Therefore we used the MOSFET dosimeter for the first time in proton dose measurements. In this study, the MOSFET dosimeter was irradiated with 190 MeV therapeutic proton beams. We experimentally evaluated dose reproducibility, linearity, fading effect, beam intensity dependence and angular dependence for the proton beam. Furthermore, the Bragg curve and spread-out Bragg peak were also measured and the linear-energy transfer (LET) dependence of the MOSFET response was investigated. Many characteristics of the MOSFET response for proton beams were the same as those for photon beams reported in previous papers. However, the angular MOSFET responses at 45, 90, 135, 225, 270 and 315 degrees for proton beams were over-responses of about 15%, and moreover the MOSFET response depended strongly on the LET of the proton beam. This study showed that the angular dependence and LET dependence of the MOSFET response must be considered very carefully for quantitative proton dose evaluations

  3. Dose Rate Effects in Linear Bipolar Transistors

    Science.gov (United States)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  4. Biological effective dose studies in carcinoma of uterine cervix

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.

    2008-01-01

    Cancer of cervix is the second most common cancer worldwide among women. Several treatments related protocols of radiotherapy have been followed over few decades in its treatment for evaluating the response. These physical doses varying on the basics of fractionation size, dose rate and total dose needed to be indicated as biological effective dose (BED) to rationalize these treatments. The curative potential of radiation therapy in the management of carcinoma of the cervix is greatly enhanced by the use of intracavitary brachytherapy. Successful brachytherapy requires the high radiation dose to be delivered to the tumor where as minimum radiation dose reach to surrounding normal tissue. Present study is aimed to evaluate biologically effective dose in patients receiving high dose-rate brachytherapy plus external beam radiotherapy based on tumor cell proliferation values in cancer of the cervix patients. The study includes 30 patients' data as a retrospective analysis. In addition determine extent of a dose-response relationship existing between the biological effective dose at Point A and the bladder and rectum and the clinical outcomes

  5. The dose-rate effect

    International Nuclear Information System (INIS)

    Steel, G.G.

    1989-01-01

    This paper presents calculations that illustrate two conclusions; for any particular cell type there will be a critical radius at which tumor control breaks down, and the radius at which this occurs is strongly dependent upon the low-dose-rate radiosensitivity of the cells

  6. Evaluation the Effect of Corn (Zea mays L. Sowing Pattern and Nitrogen Application Method on Herbicide Optimizing and Reducing Foramsulfuron (Equip® Dose

    Directory of Open Access Journals (Sweden)

    E. Izadi Darbandi

    2016-06-01

    used repeatedly as the primary mechanism of weed control. These herbicides exert strong selection pressure because of their high activity on sensitive biotypes at the rates used and because of their soil residual activity. So, the primary objective of this study was to determine the effect of some crop management strategies including sowing pattern and fertilizer application methods on herbicide optimizing and reducing foramsulfuron dose. Materials and Methods: In order to evaluate the effects of corn sowing pattern and nitrogen application methods on optimizing and reducing of foramsulfuron dose, a field experiment was conducted as split factorial, based on randomized complete block design with three replications at the Research Station, of Faculty of Agriculture, Ferdowsi University of Mashhad, in 2012. Treatments included, corn sowing methods (single-row with 75 cm distance, twine row as parallel on 75 cm width ridges sides and double row as zigzag on 75 cm width ridges sides as main plots, factorial of nitrogen application methods (broadcast and band application, nitrogen source for fertilization was urea (400 kg ha-1, and foramsulfuron doses (100, 75, 50 and 0% of recommended dose (2 liter of commercial doses applied at 4th corn leaf stage as sub plots.Weed density and frequency were recorded 10 days before corn harvesting and total weed biomass, corn biomass and seed yield were recorded at the end of the experiments per 1 m-2. Analysis of variance of data was carried out with SAS software and for means comparisons LSD (p≤0.05 test was used. Also The rectangular hyperbolic equation to describe the relationship between density and weed biomass and biomass and grain yield of maize was used Results and Discussion: Evaluation of weed flora indicated that 6 weed species (including 5 dicot. and 1 monocot. including red root pigweed (Amaranthus retroflexus L., black nightshade (Solanum nigrum L., lambsquarters (Chenopodium album L., field bindweed (Convolvolus arvensis

  7. Effective dose evaluation of head and abdomen CT exams in adult patients at the Instituto de Radiologia of Faculdade de Medicina of University of Sao Paulo, SP, Brazil

    International Nuclear Information System (INIS)

    Nersissian, Denise Y.; Scolastici, Eric F.; Doro, Renato B.; Furquim, Tania A.C.

    2013-01-01

    This paper presents an estimate of the effective dose from CTDI vol for exams of skull and abdomen in adult patients. Thereafter, measurements were taken of CTDI using an ionization chamber type pencil (Radcal Corportation, model 10 x 5 - 3CT) and cylindrical phantom of PMMA equivalent to regions of the skull (diameter = 16 cm) and abdomen (diameter = 32 cm). The results of effective dose for abdomen varied between 7,3 and 12,1 mSv and for skull between 1,4 and 5,0 mSv. Comparing with the literature data, for abdomen exams between 5 and 7 mSV and skull exams between 1 and 2 mSv, it is shown that it is possible to optimize these protocols, aiming to reduce the doses to patients

  8. Correlation between effective dose and radiological risk: general concepts

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Roberto; Yoshimura, Elisabeth Mateus; Nersissian, Denise Yanikian; Melo, Camila Souza, E-mail: pcosta@if.usp.br [Universidade de Sao Paulo (IF/USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-05-15

    The present review aims to offer an educational approach related to the limitations in the use of the effective dose magnitude as a tool for the quantification of doses resulting from diagnostic applications of ionizing radiation. We present a critical analysis of the quantities accepted and currently used for dosimetric evaluation in diagnostic imaging procedures, based on studies published in the literature. It is highlighted the use of these quantities to evaluate the risk attributed to the procedure and to calculate the effective dose, as well as to determine its correct use and interpretation. (author)

  9. Effect of low dose 131I-MIBG therapy in metastatic neural crest tumors: Evaluation by RECIST and quality of life questionnaire

    International Nuclear Information System (INIS)

    Basu, S.; Joseph, J.K.

    2004-01-01

    Full text: The primary aim of 131I-MIBG therapy in advanced metastatic or recurrent neural crest tumors is palliation i.e. disease control and improvement of health related quality of life. No clear guidelines regarding the dosage and schedule of 131I-MIBG therapy in neural crest tumors exist at present. In general, a fixed dose of 100-300 mCi has been suggested for each therapy. We share our experience of 131I-MIBG therapy in various subgroups of neural crest tumors and discuss the response assessed by the RECIST and the quality of life questionnaire. A total number of 14 patients were treated with indigenously produced 131I-MIBG, which was administered as continuous intravenous infusion over a period of 2-4 hours. Patient isolation according to guidelines set by the national regulatory authority and thyroid blockade with Lugol's iodide were strictly adhered to. Antihypertensive measures were undertaken in case of pheochromocytoma and paraganglioma to prevent effects of catecholamine release during or following 131I-MIBG infusion. The primaries included neuroblastoma (n=7), pheochromocytoma (n=5) and paraganglioma (n=2). The cases of neuroblastoma included patients with progressive disease where the conventional chemotherapy had failed, while those of pheochromocytoma and paraganglioma were cases with recurrent / metastatic disease following surgery. In cases of multiple therapies, the minimum interval between two consecutive therapies was 12 weeks. Regular renal and haematological profiles were monitored in all the cases. Response to therapy was assessed by RECIST. The findings of 131I-MIBG scintigraphy were incorporated with CT scan in assessing the target lesions. Biochemical response was evaluated by 24 hours urinary VMA estimation. The quality of life status was evaluated by the conventional questionnaire. A total of 27 therapies were administered in 14 patients. In five treated cases of pheochromocytoma, three received multiple therapies. Follow up results

  10. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  11. Evaluation of the effect of high-dose folic acid on endothelial dysfunction in pre-eclamptic patients: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Mohammad Hashemi

    2016-01-01

    Full Text Available Background: Pre-eclampsia as a hypertensive disorder of pregnancy complicates up to 5–10% of pregnancies worldwide. Endothelial dysfunction plays an important role in the pathogenesis of pre-eclampsia. In this study, we aim to evaluate the effect of high-dose folic acid on endothelial dysfunction in pre-eclamptic patients. Materials and Methods: In this triple-blinded randomized clinical trial, the enrolled patients were divided randomly into two groups. Folic acid 5.0 mg or placebo was taken daily by oral administration from the initiation of diagnosis until 2 months after delivery by the participants. Every patient's flow-mediated dilation (FMD was evaluated at the beginning of the study and 2 months after delivery with the same experienced operator at the same period of time (3–5 p.m. by high-resolution B-mode ultrasonography. Potential confounding variables were included in the independent samples t-test. t-test or Mann–Whitney U-test was used in the comparison of means between the intervention and placebo groups. To compare FMD in each group, before and after the intervention, paired t-test was used. Results: Mean value of FMD in intervention (9.64 ± 5.57 and control group (9.30 ± 4.25 has no significant difference before the consumption of drugs (P < 0.05. FMD in intervention group (13.72 ± 7.89 significantly increases after daily consumption of 5 mg folic acid in comparison with control group (10.02 ± 4.81 after daily consumption of placebo (P = 0.002. Conclusion: Increased mean of FMD in intervention group shows that this supplement can improve endothelial function and can be significantly affected by maternal blood pressure during pregnancy and some endothelium-dependent disease such as pre-eclampsia and its associated adverse outcomes.

  12. Effects of low dose mitomycin C on experimental tumor radiotherapy

    International Nuclear Information System (INIS)

    Yang Jianzheng; Liang Shuo; Qu Yaqin; Pu Chunji; Zhang Haiying; Wu Zhenfeng; Wang Xianli

    2001-01-01

    Objective: To evaluate the possibility of low dose mitomycin C(MMC) as an adjunct therapy for radiotherapy. Methods: Change in tumor size tumor-bearing mice was measured. Radioimmunoassay was used to determine immune function of mice. Results: Low dose Mac's pretreatment reduced tumor size more markedly than did radiotherapy only. The immune function in mice given with low dose MMC 12h before radiotherapy was obviously higher than that in mice subjected to radiotherapy only (P<0.05), and was close to that in the tumor-bearing mice before radiotherapy. Conclusion: Low dose MMC could improve the radiotherapy effect. Pretreatment with low dose MMC could obviously improve the immune suppression state in mice caused by radiotherapy. The mechanism of its improvement of radiotherapeutic effect by low dose of MMC might be due to its enhancement of immune function and induction of adaptive response in tumor-bearing mice

  13. Biological Effects of Low-Dose Exposure

    CERN Document Server

    Komochkov, M M

    2000-01-01

    On the basis of the two-protection reaction model an analysis of stochastic radiobiological effects of low-dose exposure of different biological objects has been carried out. The stochastic effects are the results published in the last decade: epidemiological studies of human cancer mortality, the yield of thymocyte apoptosis of mice and different types of chromosomal aberrations. The results of the analysis show that as dependent upon the nature of biological object, spontanous effect, exposure conditions and radiation type one or another form dose - effect relationship is realized: downwards concave, near to linear and upwards concave with the effect of hormesis included. This result testifies to the incomplete conformity of studied effects of 1990 ICRP recomendations based on the linear no-threshold hypothesis about dose - effect relationship. Because of this the methodology of radiation risk estimation recomended by ICRP needs more precisian and such quantity as collective dose ought to be classified into...

  14. Correct statistical evaluation for total dose in rural settlement

    International Nuclear Information System (INIS)

    Vlasova, N.G.; Skryabin, A.M.

    2001-01-01

    Statistical evaluation of dose reduced to the determination of an average value and its error. If an average value of a total dose in general can be determined by simple summarizing of the averages of its external and internal components, the evaluation of an error can be received only from its distribution. Herewith, considering that both components of the dose are interdependent, to summarize their distributions, as a last ones of a random independent variables, is incorrect. It follows that an evaluation of the parameters of the total dose distribution, including an error, in general, cannot be received empirically, particularly, at the lack or absence of the data on one of the components of the last one, that constantly is happens in practice. If the evaluation of an average for total dose was defined somehow, as the best, as an average of a distribution of the values of individual total doses, as summarizing the individual external and internal doses by the random type, that an error of evaluation had not been produced. The methodical approach to evaluation of the total dose distribution at the lack of dosimetric information was designed. The essence of it is original way of an interpolation of an external dose distribution, using data on an internal dose

  15. Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications

    International Nuclear Information System (INIS)

    Rosu, Mihaela; Chetty, Indrin J.; Balter, James M.; Kessler, Marc L.; McShan, Daniel L.; Ten Haken, Randall K.

    2005-01-01

    In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the 'tracked' locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In the second approach, the 'volume' associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field

  16. Effective dose from direct and indirect digital panoramic units

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gun Sun; Kim, Jin Soo; Seo, Yo Seob; Kim, Jae Duk [School of Dentistry, Oral Biology Research Institute, Chosun University, Gwangju (Korea, Republic of)

    2013-06-15

    This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. The effective doses of the 4 digital panoramic units ranged between 8.9 {mu}Sv and 37.8 {mu}Sv. By using the head phantom, the effective doses from the direct digital panoramic units (37.8 {mu}Sv, 27.6 {mu}Sv) were higher than those from the indirect units (8.9 {mu}Sv, 15.9 {mu}Sv). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

  17. Evaluation of shipping doses and compositions for vitrified waste

    International Nuclear Information System (INIS)

    Shapiro, A.

    1996-01-01

    Shipments of radioactive materials must adhere to dose limits specified in the Code of Federal Regulations. This paper discusses methods for evaluating shipping doses of vitrified waste. A methodology was developed for evaluating the change in vitrification composition required to maintain shipping dose rates within limits. The point kernel codes QAD and Microshield were used to evaluate dose equivalent rates from specified waste forms and radioactivity measurements. The Origen code was utilized to provide the gamma-ray activity as a function of time from isotopic activity measurements. This gamma-ray activity served as source input for QAD. Microshield developed its own source from the given isotopic activities

  18. Effects of small doses of ionising radiation

    International Nuclear Information System (INIS)

    Doll, R.

    1998-01-01

    Uncertainty remains about the quantitative effects of doses of ionising radiation less than 0.2 Sv. Estimates of hereditary effects, based on the atomic bomb survivors, suggest that the mutation doubling dose is about 2 Sv for acute low LET radiation, but the confidence limits are wide. The idea that paternal gonadal irradiation might explain the Seascale cluster of childhood leukaemia has been disproved. Fetal irradiation may lead to a reduction in IQ and an increase in seizures in childhood proportional to dose. Estimates that doses to a whole population cause a risk of cancer proportional to dose, with 0.1 Sv given acutely causing a risk of 1%, will need to be modified as more information is obtained, but the idea that there is a threshold for risk above this level is not supported by observations on the irradiated fetus or the effect of fallout. The idea, based on ecological observations, that small doses protect against the development of cancer is refuted by the effect of radon in houses. New observations on the atomic bomb survivors have raised afresh the possibility that small doses may also have other somatic effects. (author)

  19. Dose rate effect in food irradiation

    International Nuclear Information System (INIS)

    Singh, H.

    1991-08-01

    It has been suggested that the minor losses of nutrients associated with radiation processing may be further reduced by irradiating foods at the high dose rates generally associated with electron beams from accelerators, rather than at the low dose rates typical of gamma irradiation (e.g. 60 Co). This review briefly examines available comparative data on gamma and electron irradiation of foods to evaluate these suggestions. (137 refs., 27 tabs., 11 figs.)

  20. Low-dose effect on blood chromosomes

    International Nuclear Information System (INIS)

    Pohl-Rueling, J.

    1992-01-01

    Linear dose response relationships of biological effects at low doses are experimentally and theoretically disputed. Structural chromosome aberration rates at doses ranging from normal background exposures up to about 30 mGy/yr in vivo and up to 50 mGy in vitro were investigated by the author and other scientists. Results are comparable and dose effect curves reveal following shapes; within the normal burden and up to 2-10 mGy/yr in vivo rates they increase sharply to about 3-6 times the lowest values; subsequent doses either from natural, occupational or accidental exposures up to about 30 mGy/yr yield either constant aberration rates, assuming a plateau, or perhaps even a decrease. In vitro experiments show comparable results up to 50 mGy. Other biological effects seem to have similar dose dependencies. The non-linearity of low-dose effects can be explained by induction of repair enzymes at certain damage to the DNA. This hypothesis is sustained experimentally and theoretically by several papers in literature. (author). 14 refs., 5 figs

  1. Radiation effects of high and low doses

    International Nuclear Information System (INIS)

    El-Naggar, A.M.

    1998-01-01

    The extensive proliferation of the uses and applications of atomic and nuclear energy resulted in possible repercussions on human health. The prominent features of the health hazards that may be incurred after exposure to high and low radiation doses are discussed. The physical and biological factors involved in the sequential development of radiation health effects and the different cellular responses to radiation injury are considered. The main criteria and features of radiation effects of high and low doses are comprehensively outlined

  2. An evaluation of high-dose jobs for ALARA improvement

    International Nuclear Information System (INIS)

    Mun, J. H.; Kim, H. S.

    1997-01-01

    It is well known that about 70 percent of occupational dose have incurred from maintenance jobs at outage period. To reduce occupational dose, first, the high-dose jobs at the outage period should be identified and evaluated. For this, the database program is used, which contains the ORE data of reference plants, Kori Units 3 and 4. As a result, it is found that the jobs related to steam generator are the highest dose jobs in terms of collective ORE dose. From the analysis of the job procedures of those jobs, the ALARA improvements are also derived

  3. Evaluation of the sterility of single-dose medications used in a multiple-dose fashion.

    Science.gov (United States)

    Martin, Elizabeth P; Mukherjee, Jean; Sharp, Claire R; Sinnott-Stutzman, Virginia B

    2017-11-01

    Bacterial proliferation was evaluated in single-dose medications used in a multi-dose fashion and when medications were intentionally inoculated with bacteria. Of 5 experimentally punctured medications, 1 of 75 vials (50% dextrose) became contaminated. When intentionally inoculated, hydroxyethyl starch and heparinized saline supported microbial growth. Based on these findings, it is recommended that hydroxyethyl starch and heparinized saline not be used in a multi-dose fashion.

  4. Effective dose: a radiation protection quantity

    CERN Document Server

    Menzel, H G

    2012-01-01

    Modern radiation protection is based on the principles of justification, limitation, and optimisation. Assessment of radiation risks for individuals or groups of individuals is, however, not a primary objective of radiological protection. The implementation of the principles of limitation and optimisation requires an appropriate quantification of radiation exposure. The International Commission on Radiological Protection (ICRP) has introduced effective dose as the principal radiological protection quantity to be used for setting and controlling dose limits for stochastic effects in the regulatory context, and for the practical implementation of the optimisation principle. Effective dose is the tissue weighted sum of radiation weighted organ and tissue doses of a reference person from exposure to external irradiations and internal emitters. The specific normalised values of tissue weighting factors are defined by ICRP for individual tissues, and used as an approximate age- and sex-averaged representation of th...

  5. A dose-response study in animals to evaluate the anticoagulant effect of the stage 2 unfractionated heparin USP monograph change.

    Science.gov (United States)

    Honchel, R; Carraway, J; Gopee, N; Callicott, R; Chen, J; Patton, R; Xu, Q; Zalkkar, J; Laniyonu, A; Krefting, I; Cato, M; Robie-Suh, K; Rieves, R

    2011-08-01

    The United States Pharmacopeia (USP) monograph for unfractionated heparin (UFH) was revised in October 2009. This revision was anticipated, based upon in vitro tests, to reduce UFH potency by approximately 10%. To study the potential in vivo consequences of the monograph change, we evaluated activated partial thromboplastin time (aPTT) and activated clotting time (ACT) responses in animals. Female mini-pigs and monkeys (n=8/species) were administered intravenously 60, 54, 48, or 42 U/kg and 50, 45, 40, or 35 U/kg "old" (pre-USP revision) UFH, respectively, in a Williams 4×4 crossover design. Blood samples for aPTT and ACT were collected at 15 min after dosing. The same study design was then repeated using "new" (post-USP revision) UFH. Mean "new" UFH aPTT and ACT values were generally lower than those for "old" UFH although individual animal responses varied considerably. The aPTT and ACT response was generally dose-proportional for both "old" and "new" UFH. These studies indicate that the USP monograph alteration for UFH may result in a modest reduction in the anticoagulant response across a population, but the variability in animal responses underscores the importance of individualization of clinical UFH dosing and the importance of anticoagulant test monitoring. Published by Elsevier Inc.

  6. Effects of dose fractionation on the response of alanine dosimetry

    International Nuclear Information System (INIS)

    Lundahl, Brad; Logar, John; Desrosiers, Marc; Puhl, James

    2014-01-01

    Alanine dosimetry is well established as a transfer standard and is becoming more prevalently used in routine dosimetry systems for radiation processing. Many routine measurement applications in radiation processing involve absorbed dose measurements resulting from fractioned exposures to ionizing radiation. Fractioning of absorbed dose is identified as an influence quantity (ISO/ASTM, 2013). This paper reports on study results of absorbed dose fractioning characteristics of alanine for gamma and high energy electron beam radiation sources. The results of this study indicate a radiation response difference due to absorbed dose fractioning in response can be observed after four fractionations for high-energy electron beams and no difference up to seven fractions for gamma rays using an ANOVA evaluation method. - Highlights: • Fractioning effects signaled in electron beam using an ANOVA at 6 equal increments. • Fractioning effects not signaled in gamma using an ANOVA up to 7 equal increments. • Insensitivity of alanine to dose fractioning indicates nominal impact on calibration

  7. Optimal set of grid size and angular increment for practical dose calculation using the dynamic conformal arc technique: a systematic evaluation of the dosimetric effects in lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Park, Ji-Yeon; Kim, Siyong; Park, Hae-Jin; Lee, Jeong-Woo; Kim, Yeon-Sil; Suh, Tae-Suk

    2014-01-01

    To recommend the optimal plan parameter set of grid size and angular increment for dose calculations in treatment planning for lung stereotactic body radiation therapy (SBRT) using dynamic conformal arc therapy (DCAT) considering both accuracy and computational efficiency. Dose variations with varying grid sizes (2, 3, and 4 mm) and angular increments (2°, 4°, 6°, and 10°) were analyzed in a thorax phantom for 3 spherical target volumes and in 9 patient cases. A 2-mm grid size and 2° angular increment are assumed sufficient to serve as reference values. The dosimetric effect was evaluated using dose–volume histograms, monitor units (MUs), and dose to organs at risk (OARs) for a definite volume corresponding to the dose–volume constraint in lung SBRT. The times required for dose calculations using each parameter set were compared for clinical practicality. Larger grid sizes caused a dose increase to the structures and required higher MUs to achieve the target coverage. The discrete beam arrangements at each angular increment led to over- and under-estimated OARs doses due to the undulating dose distribution. When a 2° angular increment was used in both studies, a 4-mm grid size changed the dose variation by up to 3–4% (50 cGy) for the heart and the spinal cord, while a 3-mm grid size produced a dose difference of <1% (12 cGy) in all tested OARs. When a 3-mm grid size was employed, angular increments of 6° and 10° caused maximum dose variations of 3% (23 cGy) and 10% (61 cGy) in the spinal cord, respectively, while a 4° increment resulted in a dose difference of <1% (8 cGy) in all cases except for that of one patient. The 3-mm grid size and 4° angular increment enabled a 78% savings in computation time without making any critical sacrifices to dose accuracy. A parameter set with a 3-mm grid size and a 4° angular increment is found to be appropriate for predicting patient dose distributions with a dose difference below 1% while reducing the

  8. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  9. Evaluation of radiation doses delivered in different chest CT protocols

    International Nuclear Information System (INIS)

    Gorycki, Tomasz; Lasek, Iwona; Kamiński, Kamil; Studniarek, Michał

    2014-01-01

    There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDI VOL ) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer Tomography (LDCT) of the chest in comparison with routine chest CT examinations as well as to compare doses delivered in low dose chest CT with chest X-ray doses. CTDI VOL and DLP doses were taken to analysis from routine CT chest examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed in 202 adult patients with FBP reconstruction: 51 low dose, 106 helical, 20 angio CT, and 25 high resolution CT protocols, as well as 19 helical protocols with iterative ASIR reconstruction. The analysis of chest X-ray doses was made on the basis of reports from 44 examinations. Mean values of CTDI VOL and DLP were, respectively: 2.1 mGy and 85.1 mGy·cm, for low dose, 9.7 mGy and 392.3 mGy·cm for helical, 18.2 mGy and 813.9 mGy·cm for angio CT, 2.3 mGy and 64.4 mGy·cm for high resolution CT, 8.9 mGy. and 317.6 mGy·cm for helical ASIR protocols. Significantly lower CTDI VOL and DLP values were observed for low dose and high resolution CT versus the remaining CT protocols; doses delivered in CT ASIR protocols were also lower (80–81%). The ratio between medial doses in low dose CT and chest X-ray was 11.56. Radiation dose in extended chest LDCT with parameters allowing for identification of mediastinal structures and adrenal glands is still much lower than that in standard CT protocols. Effective doses predicted for LDCT may exceed those used in chest X-ray examinations by a factor of 4 to 12, depending on LDCT scan parameters. Our results, as well as results from other authors, suggest a possibility of reducing the dose by means of iterative reconstruction. Efforts towards further dose

  10. Evaluation of Patient Radiation Dose during Orthopedic Surgery

    International Nuclear Information System (INIS)

    Osman, H; Elzaki, A.; Sam, A.K.; Sulieman, A.

    2013-01-01

    The number of orthopedic procedures requiring the use of the fluoroscopic guidance has increased over the recent years. Consequently the patient exposed to un avoidable radiation doses. The aim of the current study was to evaluate patient radiation dose during these procedures.37 patients under went dynamic hip screw (DHS) and dynamic cannulated screw (DCS) were evaluated using calibrated Thermolumincent Dosimeters (TLDs), under carm fluoroscopic machines ,in three centers in Khartoum-Sudan. The mean Entrance Skin Dose (ESD) was 7.9 m Gy per procedure. The bone marrow and gonad organ exposed to significant doses. No correlation was found between ESD and Body Mass Index (BMI), or patient weight. Well correlation was found between kilo voltage applied and ESD. Orthopedic surgeries delivered lower radiation dose to patients than cardiac catheterization or hysterosalpingraphy (HSG) procedures. More study should be implemented to follow radiation dose before surgery and after surgery

  11. Organ doses and effective doses in some medical and industrial applications

    International Nuclear Information System (INIS)

    Keshavkumar, Biju

    2000-01-01

    The ICRP recommends radiation protection standards for the safe use of radiation and also prescribes the radiation protection quantities and periodically reviews them. In this context, the quantities like organ doses and effective doses are defined by ICRP. In this work we calculate these quantities and hence the conversion functions for the industrial radiation sources and those for CT and diagnostic X-ray exposures. Workers who are occupationally exposed to radiation are regularly monitored to evaluate the radiation dose received by them. It is quite possible that in an accident situation, the worker involved in the accident might not have worn a personal monitor, popularly known as the monitoring badge. In addition, even some non radiation workers (who are obviously not monitored) may also have received exposure. Under these circumstances, the persons involved are interviewed, the accident site inspected, and on the basis of realistic assumptions, the likely doses received by the exposed persons are estimated

  12. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  13. Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler

    Directory of Open Access Journals (Sweden)

    A Saravanakumar

    2015-01-01

    Full Text Available In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP. Using these values, the weighted computed tomography dose index (CTDIw and in turn the volumetric CTDI (CTDIv were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB, India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.

  14. Effective dose estimation to patients and staff during urethrography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Alkhorayef, M.; Babikir, E.; Dalton, A.; Bradley, D.

    2015-10-01

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Few data were available worldwide regarding patient and staff dose during urological ascending urethrography (ASU) procedure. The purposes of this study are to measure patient and staff entrance surface air kerma dose (ESAK) during ASU procedure and evaluate the effective doses. A total of 243 patients and 145 staff (Urologist) were examined in three Hospitals in Khartoum state. ESAKs were measured for patient and staff using thermoluminescent detectors (TLDs). Effective doses (E) were calculated using published conversion factors and methods recommended by the national Radiological Protection Board (NRPB). The mean ESAK dose for patients and staff dose were 7.79±6.7 mGy and 0.161±0.30 mGy per procedures respectively. The mean and range of the effective dose was 1.21 mSv per procedure. The radiation dose in this study is comparable with previous studies except Hospital C. It is obvious that high patient and staff exposure is due to the lack of experience and protective equipment s. Interventional procedures remain operator dependent; therefore continuous training is crucial. (Author)

  15. Effective dose estimation to patients and staff during urethrography procedures

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O- Box 422, Alkharj 11942 (Saudi Arabia); Barakat, H. [Neelain University, College of Science and Technology, Medical Physics Department, Khartoum (Sudan); Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Dalton, A.; Bradley, D. [University of Surrey, Centre for Nuclear and Radiation Physics, Department of Physics, Surrey, GU2 7XH Guildford (United Kingdom)

    2015-10-15

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Few data were available worldwide regarding patient and staff dose during urological ascending urethrography (ASU) procedure. The purposes of this study are to measure patient and staff entrance surface air kerma dose (ESAK) during ASU procedure and evaluate the effective doses. A total of 243 patients and 145 staff (Urologist) were examined in three Hospitals in Khartoum state. ESAKs were measured for patient and staff using thermoluminescent detectors (TLDs). Effective doses (E) were calculated using published conversion factors and methods recommended by the national Radiological Protection Board (NRPB). The mean ESAK dose for patients and staff dose were 7.79±6.7 mGy and 0.161±0.30 mGy per procedures respectively. The mean and range of the effective dose was 1.21 mSv per procedure. The radiation dose in this study is comparable with previous studies except Hospital C. It is obvious that high patient and staff exposure is due to the lack of experience and protective equipment s. Interventional procedures remain operator dependent; therefore continuous training is crucial. (Author)

  16. Design and development of an anthropomorphic phantom equipped with detectors in order to evaluate the effective dose E at workplaces: feasibility study; Conception et developpement d'un fantome anthropomorphe equipe de detecteurs dans le but d'evaluer la dose efficace a un poste de travail: etude de faisabilite

    Energy Technology Data Exchange (ETDEWEB)

    Furstoss, Ch

    2006-11-15

    My PhD study aims to determine the feasibility to design and develop, for photon fields, an anthropomorphic phantom equipped with detectors in order to evaluate the effective dose E at workplaces. First of all, the energy losses within the organs are calculated using the M.C.N.P.X. Monte Carlo code, in order to determine the detection positions within the different organs. Then, to decrease the number of detection positions, the organ contribution to the effective dose is studied. Finally, the characteristics of the detectors to insert and the characteristics of the phantom to use are deduced. The results show that 24 or 23 detection positions, according to the wT values (publication 60 or new recommendations of the ICRP), give a E estimation with an uncertainty of {+-}15 % from 50 keV to 4 MeV. Moreover, the interest of such an instrument is underlined while comparing the E estimation by the personal dose equivalent Hp to the E estimation by the instrumented phantom when the phantom is irradiated by point sources (worker in front of a glove box for example). Last, after the detector and phantom characteristic determination, two types of detectors and one type of phantom are selected. However, for the detectors mainly, developments are necessary. Follow up this study, the characterization and the adaptation of the detectors to the project would be interesting. Furthermore, the study to mixed photon-neutrons would be required the needs of the radiological protection community. (author)

  17. [Safety Evaluation of Rare Sugar Syrup: Single-dose Oral Toxicity in Rats, Reverse Mutation Assay, Chromosome Aberration Assay, and Acute Non-Effect Level for Diarrhea of a Single Dose in Humans].

    Science.gov (United States)

    Yamada, Takako; Iida, Tetsuo; Takamine, Satoshi; Hayashi, Noriko; Okuma, Kazuhiro

    2015-01-01

    The safety of rare sugar syrup obtained from high-fructose corn syrup under slightly alkaline conditions was studied. Mutagenicity of rare sugar syrup was assessed by a reverse mutation assay using Salmonella typhimurium and Escherichia coli, and an in vitro chromosomal aberration assay using Chinese hamster lung cell line (CHL/IU). No mutagenicity of rare sugar syrup was detected under these experimental conditions. Oral administration of single dose (15,000 mg/kg) of rare sugar syrup to rats caused no abnormalities, suggesting no adverse effect of rare sugar syrup. In humans, the acute non-effect level of rare sugar syrup for causing diarrhea was estimated as 0.9 g/kg body weight as dry solid base in both males and females.

  18. Study of the heterogeneity effects of lung in the evaluation of absorbed dose in radiotherapy; Estudo dos efeitos da heterogeneidade de pulmao na avaliacao da dose absorvida em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Luciana Tourinho

    2006-02-15

    The main objective of radiotherapy is to deliver the highest possible dose to the tumour, in order to destroy it, reducing as much as possible the doses to healthy tissues adjacent to the target volume. Therefore, it is necessary to do a planning of the treatment. The more complex is the treatment, the more difficult the planning will be, demanding computation sophisticated methods in its execution, in order to consider the heterogeneities present in the human body. Additionally, with the appearing of new radiotherapeutic techniques, that used irradiation fields of small area, for instance, the intensity modulated radiotherapy, the difficulties for the execution of a reliable treatment planning, became still larger. In this work it was studied the influence of the lung heterogeneity in the planning of the curves of percentage depth dose, PDP, obtained with the Eclipse{sup R} planning system for different sizes of irradiation fields, using the correction algorithms for heterogeneities available in the planning system: modified Batho, general Batho and equivalent tissue-air ratio. A thorax phantom, manufactured in acrylic, containing a region made of cork to simulate the lung tissue, was used. The PDP curves generated by the planning system were compared to those obtained by Monte Carlo simulation and with the use of thermoluminescent, TL, dosimetry. It was verified that the algorithms used by the Eclipse{sup R} system for the correction of heterogeneity effects are not able to generate correct results for PDP curves in the case of small fields, occurring differences of up to 100%, when the 1x1 cm{sup 2} treatment field is considered. These differences can cause a considerable subdosage in the lung tissue, reducing the possibility of the patient cure. (author)

  19. Evaluation of the absorbed dose in odontological computerized tomography

    International Nuclear Information System (INIS)

    Legnani, Adriano; Schelin, Hugo R.; Rocha, Anna Silvia P.S. da; Khoury, Helen J.

    2011-01-01

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  20. Absorbed dose evaluations in retrospective dosimetry: Methodological developments using quartz

    DEFF Research Database (Denmark)

    Bailiff, I.K.; Bøtter-Jensen, L.; Correcher, V.

    2000-01-01

    Dose evaluation procedures based on luminescence techniques were applied to 50 quartz samples extracted from bricks that had been obtained from populated or partly populated settlements in Russia and Ukraine downwind of the Chernobyl NPP. Determinations of accrued dose in the range similar to 30...

  1. An efficient dose-compensation method for proximity effect correction

    International Nuclear Information System (INIS)

    Wang Ying; Han Weihua; Yang Xiang; Zhang Yang; Yang Fuhua; Zhang Renping

    2010-01-01

    A novel simple dose-compensation method is developed for proximity effect correction in electron-beam lithography. The sizes of exposed patterns depend on dose factors while other exposure parameters (including accelerate voltage, resist thickness, exposing step size, substrate material, and so on) remain constant. This method is based on two reasonable assumptions in the evaluation of the compensated dose factor: one is that the relation between dose factors and circle-diameters is linear in the range under consideration; the other is that the compensated dose factor is only affected by the nearest neighbors for simplicity. Four-layer-hexagon photonic crystal structures were fabricated as test patterns to demonstrate this method. Compared to the uncorrected structures, the homogeneity of the corrected hole-size in photonic crystal structures was clearly improved. (semiconductor technology)

  2. Radiation dose effects, hardening of electronic components

    International Nuclear Information System (INIS)

    Dupont-Nivet, E.

    1991-01-01

    This course reviews the mechanism of interaction between ionizing radiation and a silicon oxide type dielectric, in particular the effect of electron-hole pairs creation in the material. Then effects of cumulated dose on electronic components and especially in MOS technology are examined. Finally methods hardening of these components are exposed. 93 refs

  3. Signal intensity of normal breast tissue at MR mammography on midfield: Applying a random coefficient model evaluating the effect of doubling the contrast dose

    Energy Technology Data Exchange (ETDEWEB)

    Marklund, Mette [Parker Institute: Imaging Unit, Frederiksberg Hospital (Denmark)], E-mail: mm@frh.regionh.dk; Christensen, Robin [Parker Institute: Musculoskeletal Statistics Unit, Frederiksberg Hospital (Denmark)], E-mail: robin.christensen@frh.regionh.dk; Torp-Pedersen, Soren [Parker Institute: Imaging Unit, Frederiksberg Hospital (Denmark)], E-mail: stp@frh.regionh.dk; Thomsen, Carsten [Department of Radiology, Rigshospitalet, University of Copenhagen (Denmark)], E-mail: carsten.thomsen@rh.regionh.dk; Nolsoe, Christian P. [Department of Radiology, Koge Hospital (Denmark)], E-mail: cnolsoe@dadlnet.dk

    2009-01-15

    Purpose: To prospectively investigate the effect on signal intensity (SI) of healthy breast parenchyma on magnetic resonance mammography (MRM) when doubling the contrast dose from 0.1 to 0.2 mmol/kg bodyweight. Materials and methods: Informed consent and institutional review board approval were obtained. Twenty-five healthy female volunteers (median age: 24 years (range: 21-37 years) and median bodyweight: 65 kg (51-80 kg)) completed two dynamic MRM examinations on a 0.6 T open scanner. The inter-examination time was 24 h (23.5-25 h). The following sequences were applied: axial T2W TSE and an axial dynamic T1W FFED, with a total of seven frames. At day 1, an i.v. gadolinium (Gd) bolus injection of 0.1 mmol/kg bodyweight (Omniscan) (low) was administered. On day 2, the contrast dose was increased to 0.2 mmol/kg (high). Injection rate was 2 mL/s (day 1) and 4 mL/s (day 2). Any use of estrogen containing oral contraceptives (ECOC) was recorded. Post-processing with automated subtraction, manually traced ROI (region of interest) and recording of the SI was performed. A random coefficient model was applied. Results: We found an SI increase of 24.2% and 40% following the low and high dose, respectively (P < 0.0001); corresponding to a 65% (95% CI: 37-99%) SI increase, indicating a moderate saturation. Although not statistically significant (P = 0.06), the results indicated a tendency, towards lower maximal SI in the breast parenchyma of ECOC users compared to non-ECOC users. Conclusion: We conclude that the contrast dose can be increased from 0.1 to 0.2 mmol/kg bodyweight, if a better contrast/noise relation is desired but increasing the contrast dose above 0.2 mmol/kg bodyweight is not likely to improve the enhancement substantially due to the moderate saturation observed. Further research is needed to determine the impact of ECOC on the relative enhancement ratio, and further studies are needed to determine if a possible use of ECOC should be considered a compromising

  4. Signal intensity of normal breast tissue at MR mammography on midfield: Applying a random coefficient model evaluating the effect of doubling the contrast dose

    International Nuclear Information System (INIS)

    Marklund, Mette; Christensen, Robin; Torp-Pedersen, Soren; Thomsen, Carsten; Nolsoe, Christian P.

    2009-01-01

    Purpose: To prospectively investigate the effect on signal intensity (SI) of healthy breast parenchyma on magnetic resonance mammography (MRM) when doubling the contrast dose from 0.1 to 0.2 mmol/kg bodyweight. Materials and methods: Informed consent and institutional review board approval were obtained. Twenty-five healthy female volunteers (median age: 24 years (range: 21-37 years) and median bodyweight: 65 kg (51-80 kg)) completed two dynamic MRM examinations on a 0.6 T open scanner. The inter-examination time was 24 h (23.5-25 h). The following sequences were applied: axial T2W TSE and an axial dynamic T1W FFED, with a total of seven frames. At day 1, an i.v. gadolinium (Gd) bolus injection of 0.1 mmol/kg bodyweight (Omniscan) (low) was administered. On day 2, the contrast dose was increased to 0.2 mmol/kg (high). Injection rate was 2 mL/s (day 1) and 4 mL/s (day 2). Any use of estrogen containing oral contraceptives (ECOC) was recorded. Post-processing with automated subtraction, manually traced ROI (region of interest) and recording of the SI was performed. A random coefficient model was applied. Results: We found an SI increase of 24.2% and 40% following the low and high dose, respectively (P < 0.0001); corresponding to a 65% (95% CI: 37-99%) SI increase, indicating a moderate saturation. Although not statistically significant (P = 0.06), the results indicated a tendency, towards lower maximal SI in the breast parenchyma of ECOC users compared to non-ECOC users. Conclusion: We conclude that the contrast dose can be increased from 0.1 to 0.2 mmol/kg bodyweight, if a better contrast/noise relation is desired but increasing the contrast dose above 0.2 mmol/kg bodyweight is not likely to improve the enhancement substantially due to the moderate saturation observed. Further research is needed to determine the impact of ECOC on the relative enhancement ratio, and further studies are needed to determine if a possible use of ECOC should be considered a compromising

  5. Therapeutic effects of low radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Trott, K.R. (Dept. of Radiation Biology, St. Bartholomew' s Medical College, London (United Kingdom))

    1994-01-01

    This editorial explores the scientific basis of radiotherapy with doses of < 1 Gy for various non-malignant conditions, in particular dose-effect relationships, risk-benefit considerations and biological mechanisms. A review of the literature, particularly clinical and experimental reports published more than 50 years ago was conducted to clarify the following problems. 1. The dose-response relationships for the therapeutic effects on three groups of conditions: non-malignant skin disease, arthrosis and other painful degenerative joint disorders and anti-inflammatory radiotherapy; 2. risks after radiotherapy and after the best alternative treatments; 3. the biological mechanisms of the different therapeutic effects. Radiotherapy is very effective in all three groups of disease. Few dose-finding studies have been performed, all demonstrating that the optimal doses are considerable lower than the generally recommended doses. In different conditions, risk-benefit analysis of radiotherapy versus the best alternative treatment yields very different results: whereas radiotherapy for acute postpartum mastitis may not be justified any more, the risk-benefit ratio of radiotherapy of other conditions and particularly so in dermatology and some anti-inflammatory radiotherapy appears to be more favourable than the risk-benefit ratio of the best alternative treatments. Radiotherapy can be very effective treatment for various non-malignant conditions such as eczema, psoriasis, periarthritis humeroscapularis, epicondylitis, knee arthrosis, hydradenitis, parotitis and panaritium and probably be associated with less acute and long-term side effects than similarly effective other treatments. Randomized clinical studies are required to find the optimal dosage which, at present, may be unnecessarily high.

  6. Effect of physiological factors on dose due to organically bound tritium

    International Nuclear Information System (INIS)

    Trivedi, A.

    1998-01-01

    The International Commission on Radiological Protection (ICRP) recommends the understanding of the effect of age, anatomical and physiological data on the doses in order to prescribe dose coefficient for radionuclides. The published data on OBT dose fraction after acute or chronic intakes of HTO are evaluated to examine the variation of OBT dose with the age and physiology of occupational workers. (author)

  7. Design study on dose evaluation method for employees at severe accident

    International Nuclear Information System (INIS)

    Yoshida, Yoshitaka; Irie, Takashi; Kohriyama, Tamio; Kudo, Seiichi; Nishimura, Kazuya

    2001-01-01

    When we assume a severe accident in a nuclear power plant, it is required for rescue activity in the plant, accident management, repair work of failed parts and evaluation of employees to obtain radiation dose rate distribution or map in the plant and estimated dose value for the above works. However it might be difficult to obtain them accurately along the progress of the accident, because radiation monitors are not always installed in the areas where the accident management is planned or the repair work is thought for safety-related equipments. In this work, we analyzed diffusion of radioactive materials in case of a severe accident in a pressurized water reactor plant, investigated a method to obtain radiation dose rate in the plant from estimated radioactive sources, made up a prototype analyzing system by modeling a specific part of components and buildings in the plant from this design study on dose evaluation method for employees at severe accident, and then evaluated its availability. As a result, we obtained the followings: (1) A new dose evaluation method was established to predict the radiation dose rate in any point in the plant during a severe accident scenario. (2) This evaluation of total dose including moving route and time for the accident management and the repair work is useful for estimating radiation dose limit for these actions of the employees. (3) The radiation dose rate map is effective for identifying high radiation areas and for choosing a route with lower radiation dose rate. (author)

  8. Design study on dose evaluation method for employees at severe accident

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Yoshitaka; Irie, Takashi; Kohriyama, Tamio [Institute of Nuclear Safety Systems Inc., Mihama, Fukui (Japan); Kudo, Seiichi [Mitsubishi Heavy Industries Ltd., Tokyo (Japan); Nishimura, Kazuya [Computer Software Development Co., Ltd., Tokyo (Japan)

    2001-09-01

    When we assume a severe accident in a nuclear power plant, it is required for rescue activity in the plant, accident management, repair work of failed parts and evaluation of employees to obtain radiation dose rate distribution or map in the plant and estimated dose value for the above works. However it might be difficult to obtain them accurately along the progress of the accident, because radiation monitors are not always installed in the areas where the accident management is planned or the repair work is thought for safety-related equipments. In this work, we analyzed diffusion of radioactive materials in case of a severe accident in a pressurized water reactor plant, investigated a method to obtain radiation dose rate in the plant from estimated radioactive sources, made up a prototype analyzing system by modeling a specific part of components and buildings in the plant from this design study on dose evaluation method for employees at severe accident, and then evaluated its availability. As a result, we obtained the followings: (1) A new dose evaluation method was established to predict the radiation dose rate in any point in the plant during a severe accident scenario. (2) This evaluation of total dose including moving route and time for the accident management and the repair work is useful for estimating radiation dose limit for these actions of the employees. (3) The radiation dose rate map is effective for identifying high radiation areas and for choosing a route with lower radiation dose rate. (author)

  9. Evaluation of worker's dose on a virtual dismantling environment

    International Nuclear Information System (INIS)

    Park, Hee Seong; Kim, Sung Hyun; Park, Byung Suk; Yoon, Ji Sup

    2007-01-01

    The motivation of this study is to provide a basis for a minimization of worker's dose during dismantling activities. In the present study, we proposed methods for identifying an existence of radioactivity which is contained in the dismantling objects and for evaluating a worker's dose under a virtual dismantling environment. To evaluate a worker's external dose, the shape of the exposure room in the KRR 2(Korean Research Reactor TRIGA MARK III) by 3D CAD was created and the radiation dose surrounding the facility by using MCNP- 4C(Monte Carlo N-Particle-4C) was calculated. The radiation field of the exposure room was visualized three dimensionally by using the radiation dose that was obtained by the code

  10. Pediatric Obesity: Pharmacokinetic Alterations and Effects on Antimicrobial Dosing.

    Science.gov (United States)

    Natale, Stephanie; Bradley, John; Nguyen, William Huy; Tran, Tri; Ny, Pamela; La, Kirsten; Vivian, Eva; Le, Jennifer

    2017-03-01

    Limited data exist for appropriate drug dosing in obese children. This comprehensive review summarizes pharmacokinetic (PK) alterations that occur with age and obesity, and these effects on antimicrobial dosing. A thorough comparison of different measures of body weight and specific antimicrobial agents including cefazolin, cefepime, ceftazidime, daptomycin, doripenem, gentamicin, linezolid, meropenem, piperacillin-tazobactam, tobramycin, vancomycin, and voriconazole is presented. PubMed (1966-July 2015) and Cochrane Library searches were performed using these key terms: children, pharmacokinetic, obesity, overweight, body mass index, ideal body weight, lean body weight, body composition, and specific antimicrobial drugs. PK studies in obese children and, if necessary, data from adult studies were summarized. Knowledge of PK alterations stemming from physiologic changes that occur with age from the neonate to adolescent, as well as those that result from increased body fat, become an essential first step toward optimizing drug dosing in obese children. Excessive amounts of adipose tissue contribute significantly to body size, total body water content, and organ size and function that may modify drug distribution and clearance. PK studies that evaluated antimicrobial dosing primarily used total (or actual) body weight (TBW) for loading doses and TBW or adjusted body weight for maintenance doses, depending on the drugs' properties and dosing units. PK studies in obese children are imperative to elucidate drug distribution, clearance, and, consequently, the dose required for effective therapy in these children. Future studies should evaluate the effects of both age and obesity on drug dosing because the incidence of obesity is increasing in pediatric patients. © 2017 Pharmacotherapy Publications, Inc.

  11. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    International Nuclear Information System (INIS)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young

    2016-01-01

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety

  12. Evaluation of radiation dose to patients in intraoral dental radiography using Monte Carlo Method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Il; Kim, Kyeong Ho; Oh, Seung Chul; Song, Ji Young [Dept. of Nuclear Engineering, Kyung Hee University, Yongin (Korea, Republic of)

    2016-11-15

    The use of dental radiographic examinations is common although radiation dose resulting from the dental radiography is relatively small. Therefore, it is required to evaluate radiation dose from the dental radiography for radiation safety purpose. The objectives of the present study were to develop dosimetry method for intraoral dental radiography using a Monte Carlo method based radiation transport code and to calculate organ doses and effective doses of patients from different types of intraoral radiographies. Radiological properties of dental radiography equipment were characterized for the evaluation of patient radiation dose. The properties including x-ray energy spectrum were simulated using MCNP code. Organ doses and effective doses to patients were calculated by MCNP simulation with computational adult phantoms. At the typical equipment settings (60 kVp, 7 mA, and 0.12 sec), the entrance air kerma was 1.79 mGy and the measured half value layer was 1.82 mm. The half value layer calculated by MCNP simulation was well agreed with the measurement values. Effective doses from intraoral radiographies ranged from 1 μSv for maxilla premolar to 3 μSv for maxilla incisor. Oral cavity layer (23⁓82 μSv) and salivary glands (10⁓68 μSv) received relatively high radiation dose. Thyroid also received high radiation dose (3⁓47 μSv) for examinations. The developed dosimetry method and evaluated radiation doses in this study can be utilized for policy making, patient dose management, and development of low-dose equipment. In addition, this study can ultimately contribute to decrease radiation dose to patients for radiation safety.

  13. External contamination and skin dose. From ICRP and regulations to skin dose evaluation in practice

    International Nuclear Information System (INIS)

    Le Coulteulx, I.; Apretna, D.; Beaugerie, M.; Fenolland, J.; Frey, R.; Gonin, M.; Landry, B.; Laporte, E.; Le Guen, B.; Leval, D.

    2006-01-01

    Dose limitation to the skin is an objective of radiation protection. Our aim is to propose in case of skin contamination in EDF NPPs a simply, quickly and reproducible procedure for evaluating skin dose. French regulation admit an annual limit for skin dose over one square centimeter equal to 500 mSv. ICRP Publication 26 and 60 recommend that dose assessment be performed only if skin dose might be equal to or more than 50 mSv at basal cells. To respect this recommendation, an alert value (A) must be determined. This value is the lowest value of measurement from which dose assessment has to be made, based on the hypothesis that uninterrupted work time in controlled area is no more than four hours. This alert value (A) has been established for three external detection equipments, and for the ten radionuclides commonly detected. In case of external contamination, a first measurement is performed. If the value exceeds value (A), other measurements are instituted because skin dose evaluation needs to know other parameters as: - the radioactivity of the most contaminated square centimeter of the skin, - the identity of the radionuclides and their relative proportion. At the same time, we have to evaluate the length of the exposure. At last, we use different compiled results in a program developed from excel software which allow to calculate automatically the skin dose. This work has allowed us to publish an occupational health guideline about the assessment of skin dose in case of external contamination in EDF NPPs and to create an information booklet for workers. The authors propose to examine used methodology and to demonstrate the software. (authors)

  14. The Fukushima nuclear accident and the pale grass blue butterfly: evaluating biological effects of long-term low-dose exposures.

    Science.gov (United States)

    Hiyama, Atsuki; Nohara, Chiyo; Taira, Wataru; Kinjo, Seira; Iwata, Masaki; Otaki, Joji M

    2013-08-12

    On August 9th 2012, we published an original research article in Scientific Reports, concluding that artificial radionuclides released from the Fukushima Dai-ichi Nuclear Power Plant exerted genetically and physiologically adverse effects on the pale grass blue butterfly Zizeeria maha in the Fukushima area. Immediately following publication, many questions and comments were generated from all over the world. Here, we have clarified points made in the original paper and answered questions posed by the readers. The following points were clarified. (1) There are many advantages to using the pale grass blue butterfly as an indicator species. (2) The forewings of the individuals collected in Fukushima were significantly smaller than in the northern and southern localities. (3) We observed growth retardation in the butterflies from the Fukushima area. (4) The aberrant colour patterns in the butterflies obtained in the Fukushima area were different from the colour patterns induced by temperature and sibling crosses but similar to those induced by external and internal exposures to the artificial radionuclides and by a chemical mutagen, suggesting that genetic mutations caused the aberrations. (5) This species of butterfly has been plentiful in Fukushima area for at least half a century. We here present specimens collected from Fukushima Prefecture before the accident. (6) Mutation accumulation was detected by the increase in the abnormality rates from May 2011 to September 2011. (7) The abnormal traits were heritable. (8) Our sampling localities were not affected by the tsunami. (9) We used a high enough number of samples to obtain statistically significant results. (10) The standard rearing method was followed, producing normal adults in the control groups. (11) The exposure experiments successfully reproduced the results of the field work. This species of butterfly is vulnerable to long-term low-dose internal and external exposures; however, insect cells are known to be

  15. Problems arising in the evaluation of collective dose commitment

    International Nuclear Information System (INIS)

    Coulon, R.; Beau, P.

    1979-01-01

    In order to apply the concept of optimization it is necessary to evaluate the collective dose commitment for the population as a whole. This is found by summing the dose commitments for the different population groups involved, including persons occupationally exposed and members of the public both locally and globally. The average dose received by each of these groups can vary considerably: for occupational exposure it is about one order of magnitude below the limits, whereas for the general public it is far below, although certain local groups may be subjected to a much higher exposure than the overall average. The question arises, therefore, whether certain groups should not be weighted differently in order to take into account the heterogeneity of the distribution of exposure. As far as the validity of forecast evaluations is concerned, one may assume that for occupational exposure the dose commitment over the whole period of operation of a facility can be estimated fairly accurately. The overall collective dose commitment for the public is relatively insensitive to local variations in the environment and in the public itself but is strongly dependent on long-term developments which cannot at present be forecast. For the evaluation of dose equivalent to the critical group, local variations are of considerable importance and need to be foreseen, which is not always possible. By taking into account a period which includes the annual maximum collective dose equivalent one can make some of these difficulties less severe. (author)

  16. Effect of staff training on radiation dose in pediatric CT

    Energy Technology Data Exchange (ETDEWEB)

    Hojreh, Azadeh, E-mail: azadeh.hojreh@meduniwien.ac.at [Medical University of Vienna, Department of Biological Imaging and Image-guided Therapy, Division of General and Paediatric Radiology, Waehringer Guertel 18–20, A-1090 Vienna (Austria); Weber, Michael, E-mail: michael.Weber@Meduniwien.Ac.At [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of General and Paediatric Radiology, Waehringer Guertel 18–20, A-1090 Vienna (Austria); Homolka, Peter, E-mail: peter.Homolka@Meduniwien.Ac.At [Medical University of Vienna, Centre for Medical Physics and Biomedical Engineering, Waehringer Guertel 18–20, A-1090 Vienna (Austria)

    2015-08-15

    Highlights: • Pediatric patient CT doses were compared before and after staff training. • Staff training increasing dose awareness resulted in patient dose reduction. • Application of DRL reduced number of CT's with unusually high doses. • Continuous education and training are effective regarding dose optimization. - Abstract: Objective: To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Methods: Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen–pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. Results: A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p < 0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p > 0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal–pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen–pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs – available only for CCT and thorax CT – showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Conclusions: Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice.

  17. Organ doses in interventional radiology procedures: Evaluation of software

    International Nuclear Information System (INIS)

    Tort, I.; Ruiz-Cruces, R.; Perez-Martinez, M.; Carrera, F.; Ojeda, C.; Diez de los Rios, A.

    2001-01-01

    Interventional Radiology (IR) procedures require large fluoroscopy times and important number of radiological images, so the levels of radiation to patient are high, which leads us to calculate the organ doses. The objective of this work is to estimate and make a comparison of the results given by the different software that we have to do the calculation of organ doses in complex procedures of IR. To do this, 28 patients have been selected, distributed in the 3 procedures with highest doses. The determination of organ doses and effective doses has been made using the projections utilized and different software based on Monte Carlo Methods: Eff-dose, PCXMC and Diasoft. We have obtained very high dispersion in the average organ dose between the 3 programs. In many cases, it is higher than 25% and in some particular cases, it is greater than 100%. Dispersion obtained in effective doses is not so high, being under 20% in all cases. This shows that a better solution is needed to solve the problem of the organ doses calculation; a more accurate method is necessary that brings us to a trustworthy approach to reality, and, at the moment, that we do not dispose of it. (author)

  18. Determination of radon activity concentration in drinking water and evaluation of the annual effective dose in Hassan district, Karnataka state, India

    International Nuclear Information System (INIS)

    Srinivasa, E.; Rangaswamy, D.R.; Sannappa, J.

    2015-01-01

    The radon concentration has been determined in 27 drinking water samples of Hassan district and was estimated by using emanometry technique and physicochemical parameters were estimated using standard techniques. The 222 Rn concentrations in water are varying from 0.85 ± 0.2 to 60.74 ± 2.5 Bq l -1 with an average value of 26.5 ± 1.65 Bq l -1 . This study reveals that 66 % of the drinking water samples have radon concentration level in excess of the EPA recommended maximum contamination level of 11.1 Bq l -1 . There is no significant correlation noted between radon concentration and physicochemical parameters. The mean annual effective ingestion doses received from all samples are lower than 0.1 mSv y -1 . (author)

  19. Effects of low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    Ionizing radiation of cosmic or terrestrial origin is part of the environment in which all living things have evolved since the creation of the universe. The artificial radioactivity generated by medical diagnostic and treatment techniques, some industrial activities, radioactive fallout, etc. has now been added to this natural radioactivity. This article reviews the biological effects of the low doses of ionizing radiation to which the population is thus exposed. Their carcinogenic risk cannot simply be extrapolated from what we know about high-dose exposure. (author)

  20. Health effects of daily airborne particle dose in children: Direct association between personal dose and respiratory health effects

    International Nuclear Information System (INIS)

    Buonanno, Giorgio; Marks, Guy B.; Morawska, Lidia

    2013-01-01

    Air pollution is a widespread health problem associated with respiratory symptoms. Continuous exposure monitoring was performed to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and to evaluate the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO). The mean daily alveolar deposited surface area dose received by children was 1.35 × 10 3 mm 2 . The lowest and highest particle number concentrations were found during sleeping and eating time. A significant negative association was found between changes in pulmonary function tests and individual dose estimates. Significant differences were found for asthmatics, children with allergic rhinitis and sensitive to allergens compared to healthy subjects for eNO. Variation is a child's activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles. -- Highlights: •Particle dose was estimated through personal monitoring on more than 100 children. •We focused on real-time daily dose of particle alveolar deposited surface area. •Spirometry, skin prick and exhaled Nitric Oxide tests were performed. •Negative link was found between changes in pulmonary functions and individual doses. •A child's lifestyle appeared to have a strong impact on health respiratory outcomes. -- The respiratory health effects of daily airborne particle dose on children through personal monitoring

  1. Evaluating correlation between geometrical relationship and dose difference caused by respiratory motion using statistical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Dong Seok; Kim, Dong Su; Kim, Tae Ho; Kim, Kyeong Hyeon; Yoon, Do Kun; Suh, Tae Suk [The Catholic University of Korea, Seoul (Korea, Republic of); Kang, Seong Hee [Seoul National University Hospital, Seoul (Korea, Republic of); Cho, Min Seok [Asan Medical Center, Seoul (Korea, Republic of); Noh, Yu Yoon [Eulji University Hospital, Daejeon (Korea, Republic of)

    2017-04-15

    Three-dimensional dose (3D dose) can consider coverage of moving target, however it is difficult to provide dosimetric effect which occurs by respiratory motions. Four-dimensional dose (4D dose) which uses deformable image registration (DIR) algorithm from four-dimensional computed tomography (4DCT) images can consider dosimetric effect by respiratory motions. The dose difference between 3D dose and 4D dose can be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The purpose of this study is to evaluate the correlation between the overlap volume histogram (OVH), which quantitatively shows the geometrical relationship between the PTV and OAR, and the dose differences. In conclusion, no significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value. No significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value.

  2. Clinical implementation and evaluation of the Acuros dose calculation algorithm.

    Science.gov (United States)

    Yan, Chenyu; Combine, Anthony G; Bednarz, Greg; Lalonde, Ronald J; Hu, Bin; Dickens, Kathy; Wynn, Raymond; Pavord, Daniel C; Saiful Huq, M

    2017-09-01

    The main aim of this study is to validate the Acuros XB dose calculation algorithm for a Varian Clinac iX linac in our clinics, and subsequently compare it with the wildely used AAA algorithm. The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were validated by comparing calculated dose with measured dose on a homogeneous water phantom for field sizes ranging from 6 cm × 6 cm to 40 cm × 40 cm. Central axis and off-axis points with different depths were chosen for the comparison. In addition, the accuracy of Acuros was evaluated for wedge fields with wedge angles from 15 to 60°. Similarly, variable field sizes for an inhomogeneous phantom were chosen to validate the Acuros algorithm. In addition, doses calculated by Acuros and AAA at the center of lung equivalent tissue from three different VMAT plans were compared to the ion chamber measured doses in QUASAR phantom, and the calculated dose distributions by the two algorithms and their differences on patients were compared. Computation time on VMAT plans was also evaluated for Acuros and AAA. Differences between dose-to-water (calculated by AAA and Acuros XB) and dose-to-medium (calculated by Acuros XB) on patient plans were compared and evaluated. For open 6 MV photon beams on the homogeneous water phantom, both Acuros XB and AAA calculations were within 1% of measurements. For 23 MV photon beams, the calculated doses were within 1.5% of measured doses for Acuros XB and 2% for AAA. Testing on the inhomogeneous phantom demonstrated that AAA overestimated doses by up to 8.96% at a point close to lung/solid water interface, while Acuros XB reduced that to 1.64%. The test on QUASAR phantom showed that Acuros achieved better agreement in lung equivalent tissue while AAA underestimated dose for all VMAT plans by up to 2.7%. Acuros XB computation time was about three times faster than AAA for VMAT plans, and

  3. Dose-effect relationships for the US radium dial painters

    International Nuclear Information System (INIS)

    Thomas, R.G.

    1995-01-01

    Dose-response data are presented from a large percentage of the US workers who were exposed to radium through the painting of luminous dials. The data in this paper are only from females, because very few males worked in this occupation. Log-normal analyses were done for radium-induced bone sarcomas and head carcinomas after the populations of the respective doses were first determined to be log-normally distributed. These populations included luminisers who expressed no radium-related cancerous condition. In this study of the female radium luminisers, the most important data concerning radiation protection are probably from workers who were exposed to radium but showed no cancer incidence. A total of 1391 subjects with average measured skeletal doses below 10 Gy are in this category. A primary purpose is to illustrate the strong case that 226,228 Ra is representative of those radionuclides that exemplify in humans a 'threshold' dose, a dose below which there has been no observed health effects on the exposed individual. Application of a threshold dose for radium deposited in the skeleton does not mean to imply that any other source of skeletal irradiation should be considered to follow a similar pattern. Second, a policy issue that begs for attention is the economic consequence of forcing radiation to appear as a highly toxic insult. It is time to evaluate the data objectively instead of formatting the extrapolation scheme beforehand and forcing the data to fit a preconceived pattern such as linearity through the dose-effect origin. In addition, it is time to re-evaluate (again) variations in background radiation levels throughout the world and to cease being concerned with, and regulating against, miniscule doses for which no biomedical effects on humans have ever been satisfactorily identified or quantified. (author)

  4. Personal dosimetry statistics and specifics of low dose evaluation

    International Nuclear Information System (INIS)

    Avila, R.E.; Gómez Salinas, R.A.; Oyarzún Cortés, C.H.

    2015-01-01

    The dose statistics of a personal dosimetry service, considering 35,000+ readings, display a sharp peak at low dose (below 0.5 mSv) with skewness to higher values. A measure of the dispersion is that approximately 65% of the doses fall below the average plus 2 standard deviations, an observation which may prove helpful to radiation protection agencies. Categorizing the doses by the concomitant use of a finger ring dosimeter, that skewness is larger in the whole body, and ring dosimeters. The use of Harshaw 5500 readers at high gain leads to frequent values of the glow curve that are judged to be spurious, i.e. values not belonging to the roughly normal noise over the curve. A statistical criterion is shown for identifying those anomalous values, and replacing them with the local behavior, as fit by a cubic polynomial. As a result, the doses above 0.05 mSv which are affected by more than 2% comprise over 10% of the data base. The low dose peak of the statistics, above, has focused our attention on the evaluation of LiF(Mg,Ti) dosimeters exposed at low dose, and read with Harshaw 5500 readers. The standard linear procedure, via an overall reader calibration factor, is observed to fail at low dose, in detailed calibrations from 0.02 mSv to 1 Sv. A significant improvement is achieved by a piecewise polynomials calibration curve. A cubic, at low dose is matched, at ∼10 mSv, in value and first derivative, to a linear dependence at higher doses. This improvement is particularly noticeable below 2 mSv, where over 60% of the evaluated dosimeters are found. (author)

  5. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography

    International Nuclear Information System (INIS)

    Lopes, Cintya Carolina Barbosa

    2006-04-01

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  6. Committed effective dose from thoron daughters inhalation

    International Nuclear Information System (INIS)

    Campos, M.P.; Pecequilo, B.R.S.

    2000-01-01

    Mankind's interest in natural radiation exposure levels has increased over the past fifty years and it is now recognized that the most significant contributors to human irradiation by natural sources are the short-lived decay products of radon ( 222 Rn) and thoron ( 220 Rn). Despite the thoron short half-life of 55 s, effective dose from inhalation of thoron an its progeny ( 212 Pb and 212 Bi) must be considered, owing to the high thorium background in countries like Brazil, China and India, for example. The indoor committed effective dose was assessed by air sampling at the thorium purification plant and the nuclear materials storage site of the Instituto de Pesquisas Energeticas e Nucleares; Sao Paulo, Brazil. A total of 21 glass fiber filter samples was analyzed by high resolution gamma ray spectrometry in order to obtain the 212 Pb and 212 Bi activities. The equilibrium equivalent concentration (EEC) varied from 0.3 Bq/m 3 to 6.8 Bq/m 3 for the storage site air samples and from 9.9 Bq/m 3 to 249.8 Bq/m 3 for the thorium purification plant air samples. As retention studies indicate a biological half-life of a few hours inhaled thoron progeny in the human lungs, the main fraction of the potential alpha energy (PAEC) deposited is absorbed in the lungs, meaning negligible to the effective dose the contribution of the dose in other times. The committed effective dose due thoron progeny was performed by compartimental analysis following the ICRP 66 lung compartimental model and ICRP 67 lead compartimental model. The values obtained varied from 0.03 mSv/a to 0.67 mSv/a for the storage site air samples and from 0.12 mSv/a to 6.00 mSv/a for the thorium purification plant air samples. (author)

  7. Effects of low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Masse, R.

    2006-01-01

    Several groups of human have been irradiated by accidental or medical exposure, if no gene defect has been associated to these exposures, some radioinduced cancers interesting several organs are observed among persons exposed over 100 to 200 mSv delivered at high dose rate. Numerous steps are now identified between the initial energy deposit in tissue and the aberrations of cell that lead to tumors but the sequence of events and the specific character of some of them are the subject of controversy. The stake of this controversy is the risk assessment. From the hypothesis called linear relationship without threshold is developed an approach that leads to predict cancers at any tiny dose without real scientific foundation. The nature and the intensity of biological effects depend on the quantity of energy absorbed in tissue and the modality of its distribution in space and time. The probability to reach a target (a gene) associated to the cancerating of tissue is directly proportional to the dose without any other threshold than the quantity of energy necessary to the effect, its probability of effect can be a more complex function and depends on the quality of the damage produced as well as the ability of the cell to repair the damage. These two parameters are influenced by the concentration of initial injuries in the target so by the quality of radiation and by the dose rate. The mechanisms of defence explain the low efficiency of radiation as carcinogen and then the linearity of effects in the area of low doses is certainly the least defensible scientific hypothesis for the prediction of the risks. (N.C.)

  8. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    International Nuclear Information System (INIS)

    Han, Su Chul; Hong, Dong Hee

    2016-01-01

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures

  9. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Division of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Hong, Dong Hee [Dept. of Radiology Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

  10. Effective dose measurement at workplaces within an instrumented anthropomorphic phantom

    International Nuclear Information System (INIS)

    Villagrasa, C.; Darreon, J.; Martin-Burtat, N.; Clairand, I.; Colin, J.; Fontbonne, J. M.

    2011-01-01

    The Laboratory of Ionizing Radiation Dosimetry of the IRSN (France) is developing an instrumented anthropomorphic phantom in order to measure the effective dose for photon fields at workplaces. This anthropomorphic phantom will be equipped with small active detectors located inside at chosen positions. The aim of this paper is to present the development of these new detectors showing the results of the characterisation of the prototype under metrological conditions. New evaluations of the effective dose for standard and non-homogenous irradiation configurations taking into account the real constraints of the project have been done validating the feasibility and utility of the instrument. (authors)

  11. Evaluation of patient dose in some mammography centres in Iran

    International Nuclear Information System (INIS)

    Paknyat, A.; Samarin, E. R. P.; Jeshvaghane, N. A.; Paydar, R.; Fasaei, B.; Karamloo, A.; Khosravi, H. R.; Deevband, M. R.

    2011-01-01

    High diagnostic sensitivity and specificity while maintaining the least dose to the patient is the ideal mammography. The objective of this work was to evaluate patient dose and image quality of mammograms to propose corrective actions. The image quality for 1242 patient in 7 mammography facilities in Tehran city was evaluated based on selected image quality criteria using a three-point scale. Clinical image quality, the entrance surface air kerma, the average glandular dose and optical density of films for standard PMMA phantom of 4.5 cm thickness were evaluated. The results showed that up to 72 % of mammograms were in good condition to be diagnosed, and only about 3.4 % of the images were unacceptable or with suboptimal quality. The entrance surface air kerma values were in the range of 3.8-10.5 mGy, average glandular dose 0.5-1.8 mGy and optical density of films 0.74-2.03. The image quality evaluation after correction actions, periodic image quality evaluation and using the correct equipment certainly will improve patient dose. (authors)

  12. Effect of basic fog of medical x-ray films on image quality and patient dose-method of evaluation and steps to control

    International Nuclear Information System (INIS)

    Bohra, Reena; Nair, C.P.R.; Jayalakshmi, V.; Govindarajan, K.N.; Bhatt, B.C.

    2003-01-01

    Unacceptable basic fog of medical x-ray films has been reported recently from many hospitals. The paper presents the effect of basic fog on radiographic quality of films like sensitivity (speed), contrast and maximum density (DMax). Several batches of general- purpose medical x-ray films from five different manufacturers were studied to evaluate batch-to-batch variation in basic fog. Increase in basic fog with aging of films was also evaluated. Reasons for increased basic fog observed in the film processing facilities of a few hospitals were analysed. Factors responsible for increase in basic fog and the steps to control it have been discussed

  13. The Effect of Low‑Dose Ketamine (Preemptive Dose) on ...

    African Journals Online (AJOL)

    Average dosage of diclofenac suppository and mean time for taking the first dosage of opioids have not statistical difference too (respectively; P = 0.76, P = 0.87). Average dose of pethidine was lesser than placebo statistically. It means, the case group did not take pethidine but this amount was 6 (20%) in the control one (P ...

  14. Antipsychotic treatment dosing profile in patients with schizophrenia evaluated with electronic monitoring (MEMS®).

    Science.gov (United States)

    Acosta, Francisco J; Ramallo-Fariña, Yolanda; Bosch, Esperanza; Mayans, Teresa; Rodríguez, Carlos J; Caravaca, Ana

    2013-05-01

    Although the Medication Event Monitoring System (MEMS®) device offers accurate information on treatment dosing profile, such profile has never been studied in patients with schizophrenia. Enhancing our knowledge on this issue would help in developing intervention strategies to improve adherence to antipsychotic treatment in these patients. 74 outpatients with schizophrenia were monitored with the MEMS device for a 3-month period, for evaluation of antipsychotic treatment dosing profile, possible influence of medication schedule-related variables, adherence to treatment--considering dose intake within prescribed timeframes--and possible Hawthorne's effect of using the MEMS device. Dose-omission gaps occurred in 18.7% of monitoring days, most frequently during weekends, almost significantly. Almost one-third of prescribed doses were taken out of prescribed time. Neither the prescribed number of daily doses nor the indicated time of the day for dose intake (breakfast, dinner), were associated with correct antipsychotic dosing. Excess-dose was rare in general, and more frequent out of prescribed dose timeframe. No Hawthorne's effect was found for the MEMS device. Adherence reached only 35% according to a definition that included dose intake within prescribed timeframes. Antipsychotic treatment dosing was considerably irregular among patients with schizophrenia. Strategies to reduce dose-omission gaps and increase dosing within prescribed timeframes seem to be necessary. Gaining knowledge on precise oral antipsychotic dosing profiles or the influence of schedule-related variables may be useful to design strategies towards enhancing adherence. There appears to be no Hawthorne's effect associated with the use of MEMS devices in outpatients with schizophrenia. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Equivalent uniform dose concept evaluated by theoretical dose volume histograms for thoracic irradiation.

    Science.gov (United States)

    Dumas, J L; Lorchel, F; Perrot, Y; Aletti, P; Noel, A; Wolf, D; Courvoisier, P; Bosset, J F

    2007-03-01

    The goal of our study was to quantify the limits of the EUD models for use in score functions in inverse planning software, and for clinical application. We focused on oesophagus cancer irradiation. Our evaluation was based on theoretical dose volume histograms (DVH), and we analyzed them using volumetric and linear quadratic EUD models, average and maximum dose concepts, the linear quadratic model and the differential area between each DVH. We evaluated our models using theoretical and more complex DVHs for the above regions of interest. We studied three types of DVH for the target volume: the first followed the ICRU dose homogeneity recommendations; the second was built out of the first requirements and the same average dose was built in for all cases; the third was truncated by a small dose hole. We also built theoretical DVHs for the organs at risk, in order to evaluate the limits of, and the ways to use both EUD(1) and EUD/LQ models, comparing them to the traditional ways of scoring a treatment plan. For each volume of interest we built theoretical treatment plans with differences in the fractionation. We concluded that both volumetric and linear quadratic EUDs should be used. Volumetric EUD(1) takes into account neither hot-cold spot compensation nor the differences in fractionation, but it is more sensitive to the increase of the irradiated volume. With linear quadratic EUD/LQ, a volumetric analysis of fractionation variation effort can be performed.

  16. Evaluation of the Occupational Doses of Interventional Radiologists

    International Nuclear Information System (INIS)

    Kuipers, Gerritjan; Velders, Xandra L.; Winter, Robbert J. de; Reekers, Jim A.; Piek, Jan J.

    2008-01-01

    The aim of the present study was to determine whether there is a linear relation between the doses measured above and those measured under the lead apron of the radiologists performing interventional procedures. To monitor radiation exposure the International Commission of Radiological Protection (ICRP) recommends the use of a single dosimeter under the protective apron. To determine the exposure more accurately an additional dosimeter is recommended above the protective apron. The exposure of eight radiologists was monitored with two personal dosimeters during 3 consecutive years. To measure the doses uniformly the two dosimeters were worn in a special holder attached to the lead apron. The two personal dosimeters were replaced every 4 weeks on the same day. The doses above and under the protective aprons of seven radiologists did not differ significantly. A significant lower dose above and under the protective apron was measured for one of the radiologists. During a 4-week period the average dose measured above the lead apron was 3.44 mSv (median, 3.05 mSv), while that under the 0.25-mm lead apron was 0.12 mSv (median, 0.1 mSv). The coefficients of the regression line result in the equation Y = 0.036X - 0.004, with Y as the dose under the lead apron and X as the dose above the lead apron. The statistical analysis of the data established a linear relation between the doses above and those under the lead apron (R 2 = 0.59). Before the special holder was introduced it was not possible to derive a relation between the doses above and those under the lead apron, as the doses were measured at varying places above and under the lead apron. There is no evidence that the effective dose can be estimated more accurately when an additional dosimeter is used. The present study revealed a threshold before doses under the lead apron were measured. Due to the threshold it can be concluded that the doses under the lead apron will not be underestimated easily when doses above the

  17. A comparison of the angular dependence of effective dose and effective dose equivalent

    International Nuclear Information System (INIS)

    Sitek, M.A.; Gierga, D.P.; Xu, X.G.

    1996-01-01

    In ICRP (International Commission on Radiological Protection) Publication 60, the set of critical organs and their weighing factors were changed, defining the quantity effective dose, E. This quantity replaced the effective dose equivalent, H E , as defined by ICRP 26. Most notably, the esophagus was added to the list of critical organs. The Monte Carlo neutron/photon transport code MCNP was used to determine the effective dose to sex-specific anthropomorphic phantoms. The phantoms, developed in previous research, were modified to include the esophagus. Monte Carlo simulations were performed for monoenergetic photon beams of energies 0.08 MeV, 0.3 MeV, and 1.0 MeV for various azimuthal and polar angles. Separate organ equivalent doses were determined for male and female phantoms. The resulting organ equivalent doses were calculated from arithmetic mean averages. The angular dependence of effective dose was compared with that of effective dose equivalent reported in previous research. The differences between the two definitions and possible implications to regulatory agencies were summarized

  18. Dose evaluation for external exposure in radiation accidents

    International Nuclear Information System (INIS)

    Maruyama, Takashi

    1989-01-01

    Abnormal exposures including emergency and accidental are categorized into external exposure and internal contamination, although both of these may be associated with external contamination. From a point of view of lifesaving in the abnormal exposures, it is primarily important to evaluate radiation dose of exposed persons as soon as possible. This report reviews the status of early dosimetry in the accidental exposures and discusses the optimum methodology of the early dose determination for external exposures in abnormal exposures. Personal monitors generally give an indication of dose to an exposed person only at a single part of the body. The data obtained from the personal monitors should be interpreted with care and in the light of information about the circumstances of exposure. In most cases, the records of environmental monitors or the survey with area monitors provide valuable information on the radiation fields. In the some cases, the reconstruction of the abnormal exposure is required for the dose evaluation by means of phantom experiments. In the case of neutron exposures, activation products in the body or its components or personnel possession can be useful for the early dosimetry. If the dose received by the whole body is evaluated as being very high, clinical observations and biological investigations may be more important guide to initial medical treatment than the early dosimetry. For the dose evaluation of general public, depending on the size of abnormal exposure, information that could be valuable in the assessment of abnormal exposures will come from the early dose estimates with environmental monitors and radiation survey meters. (author)

  19. Modifying effect of low dose irradiation

    International Nuclear Information System (INIS)

    Kalendo, G.S.

    1989-01-01

    It is shown that irradiation of Hela cells with stimulating doses of 0,1 Gy changes the cells' response to the subsequent radiation effect of greater value: instead of DNA synthesis inhibition stimulation takes place. Modifying effect of preliminary irradiation with 0,1 Gy manifests it self only in case if there is a certain time interval not less than 3 minutes and not more than 10 minutes (3-5 minutes is optimal interval). Data on modifying effect with 0,1 Gy at subcellular and cellular-population levels are presented. 21 refs.; 6 figs

  20. SU-G-TeP4-05: An Evaluation of a Low Dose Rate (LDR) Prostate Brachytherapy Procedure Using a Failure Modes and Effects Analysis (FMEA)

    International Nuclear Information System (INIS)

    Cheong, S-K; Kim, J

    2016-01-01

    Purpose: The aim of the study is the application of a Failure Modes and Effects Analysis (FMEA) to access the risks for patients undergoing a Low Dose Rate (LDR) Prostate Brachytherapy Treatment. Methods: FMEA was applied to identify all the sub processes involved in the stages of identifying patient, source handling, treatment preparation, treatment delivery, and post treatment. These processes characterize the radiation treatment associated with LDR Prostate Brachytherapy. The potential failure modes together with their causes and effects were identified and ranked in order of their importance. Three indexes were assigned for each failure mode: the occurrence rating (O), the severity rating (S), and the detection rating (D). A ten-point scale was used to score each category, ten being the number indicating most severe, most frequent, and least detectable failure mode, respectively. The risk probability number (RPN) was calculated as a product of the three attributes: RPN = O X S x D. The analysis was carried out by a working group (WG) at UPMC. Results: The total of 56 failure modes were identified including 32 modes before the treatment, 13 modes during the treatment, and 11 modes after the treatment. In addition to the protocols already adopted in the clinical practice, the prioritized risk management will be implanted to the high risk procedures on the basis of RPN score. Conclusion: The effectiveness of the FMEA method was established. The FMEA methodology provides a structured and detailed assessment method for the risk analysis of the LDR Prostate Brachytherapy Procedure and can be applied to other radiation treatment modes.

  1. A randomized double-blinded placebo-controlled study to evaluate an effective ciclosporin dose for the treatment of feline hypersensitivity dermatitis.

    Science.gov (United States)

    King, Stephen; Favrot, Claude; Messinger, Linda; Nuttall, Tim; Steffan, Jean; Forster, Sophie; Seewald, Wolfgang

    2012-10-01

    Hypersensitivity dermatitides (HD) are frequently suspected in cats, but there are few clinical studies on safe and effective treatments in the published literature. To establish a safe and effective dose of ciclosporin in the treatment of feline HD. One hundred client-owned cats with feline HD. Double-blind study, with cats randomly assigned to receive ciclosporin at either 7.0 mg/kg once daily (n = 33) or 2.5 mg/kg once daily (n = 32) or a placebo (n = 35) for 6 weeks. Mean Total Lesion Scores with 7.0 mg/kg ciclosporin were significantly lower than with 2.5 mg/kg ciclosporin (P = 0.0047) or placebo (P = 0.0003) at study end. Individual Total Lesion Scores improved by >50% in 70% of the 7.0 mg/kg group, compared with 47% in the 2.5 mg/kg group and 23% in the placebo group (P = 0.0006). The investigators' Global Assessment of Improvement was 'excellent' or 'good' in 61% of cats treated with 7.0 mg/kg ciclosporin, compared with 47% of cats given 2.5 mg/kg and 23% given placebo. The improvement in Investigator Pruritus Scores was significantly greater in cats treated with 7.0 mg/kg ciclosporin (54%) compared with both 2.5 mg/kg ciclosporin (32%; P = 0.0232) and placebo (21%; P = 0.0063). Mild gastrointestinal disorders were the most common adverse events, but these did not require cessation of therapy. Results suggest that 7.0 mg/kg ciclosporin once daily in food or per os for 6 weeks is effective and well tolerated in feline HD. © 2012 The Authors. Veterinary Dermatology © 2012 ESVD and ACVD.

  2. SU-G-TeP4-05: An Evaluation of a Low Dose Rate (LDR) Prostate Brachytherapy Procedure Using a Failure Modes and Effects Analysis (FMEA)

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, S-K; Kim, J [University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2016-06-15

    Purpose: The aim of the study is the application of a Failure Modes and Effects Analysis (FMEA) to access the risks for patients undergoing a Low Dose Rate (LDR) Prostate Brachytherapy Treatment. Methods: FMEA was applied to identify all the sub processes involved in the stages of identifying patient, source handling, treatment preparation, treatment delivery, and post treatment. These processes characterize the radiation treatment associated with LDR Prostate Brachytherapy. The potential failure modes together with their causes and effects were identified and ranked in order of their importance. Three indexes were assigned for each failure mode: the occurrence rating (O), the severity rating (S), and the detection rating (D). A ten-point scale was used to score each category, ten being the number indicating most severe, most frequent, and least detectable failure mode, respectively. The risk probability number (RPN) was calculated as a product of the three attributes: RPN = O X S x D. The analysis was carried out by a working group (WG) at UPMC. Results: The total of 56 failure modes were identified including 32 modes before the treatment, 13 modes during the treatment, and 11 modes after the treatment. In addition to the protocols already adopted in the clinical practice, the prioritized risk management will be implanted to the high risk procedures on the basis of RPN score. Conclusion: The effectiveness of the FMEA method was established. The FMEA methodology provides a structured and detailed assessment method for the risk analysis of the LDR Prostate Brachytherapy Procedure and can be applied to other radiation treatment modes.

  3. Evaluation of dose to cardiac structures during breast irradiation

    DEFF Research Database (Denmark)

    Aznar, M C; Korreman, S-S; Pedersen, A N

    2011-01-01

    delivered to the heart and the LAD in respiration-adapted radiotherapy of patients with left-sided breast cancer. METHODS: 24 patients referred for adjuvant radiotherapy after breast-conserving surgery for left-sided lymph node positive breast cancer were evaluated. The whole heart, the arch of the LAD...... and the whole LAD were contoured. The radiation doses to all three cardiac structures were evaluated. RESULTS: For 13 patients, the plans were acceptable based on the criteria set for all 3 contours. For seven patients, the volume of heart irradiated was well below the set clinical threshold whereas a high dose...

  4. Dose and Dose-Rate Effectiveness Factor (DDREF); Der Dosis- und Dosisleistungs-Effektivitaetsfaktor (DDREF)

    Energy Technology Data Exchange (ETDEWEB)

    Breckow, Joachim [Fachhochschule Giessen-Friedberg, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2016-08-01

    For practical radiation protection purposes it is supposed that stochastic radiation effects a determined by a proportional dose relation (LNT). Radiobiological and radiation epidemiological studies indicated that in the low dose range a dependence on dose rates might exist. This would trigger an overestimation of radiation risks based on the LNT model. OCRP had recommended a concept to combine all effects in a single factor DDREF (dose and dose-Rate effectiveness factor). There is still too low information on cellular mechanisms of low dose irradiation including possible repair and other processes. The Strahlenschutzkommission cannot identify a sufficient scientific justification for DDREF and recommends an adaption to the actual state of science.

  5. Problems linked to effects of ionizing radiations low doses

    International Nuclear Information System (INIS)

    Anon.

    1995-10-01

    The question of exposure to ionizing radiations low doses and risks existing for professional and populations has been asked again, with the recommendations of the International Commission of Radiation Protection (ICRP) to lower the previous standards and agreed as guides to organize radiation protection, by concerned countries and big international organisms. The sciences academy presents an analysis which concerned on epidemiological and dosimetric aspects in risk estimation, on cellular and molecular aspects of response mechanism to irradiation. The observation of absence of carcinogen effects for doses inferior to 200 milli-sieverts and a re-evaluation of data coming from Nagasaki and Hiroshima, lead to revise the methodology of studies to pursue, to appreciate more exactly the effects of low doses, in taking in part, particularly, the dose rate. The progress of molecular and cellular biology showed that the extrapolation from high doses to low doses is not in accordance with actual data. The acknowledge of DNA repair and carcinogenesis should make clearer the debate. (N.C.). 61 refs., 9 annexes

  6. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2013-05-15

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  7. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    International Nuclear Information System (INIS)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei

    2013-01-01

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  8. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.

    Science.gov (United States)

    Zeng, Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A; Trofimov, Alexei

    2013-05-01

    Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability

  9. Evaluation of radiation dose received in skull radiographic examination

    International Nuclear Information System (INIS)

    Omer, Noora Elshiekh

    2014-12-01

    Diagnostic X-ray examination play an important role in the health care of the population. These examinations may involve significant irradiation of the patient and probably represent the largest mam-made source of radiation exposure for the population. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study was performed to assess the effective dose (ED) received in skull radiographic examination and to analyze effective dose distributions among radiological department under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded: age, weight, height, body mass index (BMI) derived from weight (kg) and (height (m)) and exposure factors. The dose was measured for skull x-ray examinations. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for skull AP and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were calculated from energy imparted using ED conversion factors proposed were within the normal range of exposure. The mean ED values calculated were 3.03±0.08 and 4.23±0.61 for skull AP and lateral examination, respectively. Further studies are recommended with more number of patients and using more than two modalities for comparison. (Author)

  10. Evaluation of doses delivered during CT examination by different scanners for purposes of intercomparison and dose optimization

    International Nuclear Information System (INIS)

    Bashiru, Adam

    2017-07-01

    This research study was aimed at performing dosimetry intercomparison on different CT scanners in the diagnostic radiology departments of Korle-Bu Teaching Hospital (KBTH), Sweden Ghana Medical Center (SGMC) and Global Medical and Imaging Center (GMIC). Using the standard body phantom and integrated ion chamber technique volume computed tomography dose index (CTDIvol) and Dose-Length Product (DLPs) within the phantom were evaluated. The ion chamber technique was applied to two 16 slice Siemens and one Toshiba Aquilion one CT scanners. CTDIvol and DLP values for the standard body polymethyl methacrylate (PMMA) phantom were estimated and comparison made with corresponding console displayed values for accuracy and also to deduce a suitable method for optimization of patients and occupationally exposed worker doses. Effective doses were also calculated. An intra and inter institutional comparison of measured doses and console displayed doses were performed. Chest protocol at Automatic Exposure Control (AEC) was applied during the scanning of the phantom. Estimated CTDIvol values (mGy) were 17mGy, 24mGy and 13.1mGy for SGMC, GMIC and KBTH respectively. These values deviated from the console displayed values by 24.1%, 22.9% and 31.3% respectively. Similarly, estimated DLP values (mGy.cm) were 675mGy.cm,944mGy.cm and 419mGy.cm for SGMC, GMIC and KBTH respectively deviating from the console displayed values by 24.1%, 24.2% and 29% respectively. In terms of effective doses (E), the calculated E (mSv) values were 9.45mSv, 13.2mSv and 5.87mSv estimated from the DLPs from SGMC, GMIC and KBTH respectively using K, the anatomy-specific dose coefficient expressing effective dose normalized to DLP in a standard CT dosimetry phantom of 0.014 mSv mGy-1 cm-1. The estimated doses were compared to other selected international Dose Reference Levels (DRLs) and were within range. (au)

  11. Design study on dose evaluation method for employees at severe accident

    International Nuclear Information System (INIS)

    Yoshida, Yoshitaka; Irie, Takashi; Kohriyama, Tamio; Kudo, Seiichi; Nishimura, Kazuya

    2002-01-01

    If a severe accident occurs in a pressurized water reactor plant, it is required to estimate dose values of operators engaged in emergency such as accident management, repair of failed parts. However, it might be difficult to measure radiation dose rate during the progress of an accident, because radiation monitors are not always installed in areas where the emergency activities are required. In this study, we analyzed the transport of radioactive materials in case of a severe accident, investigated a method to obtain radiation dose rate in the plant from estimated radioactive sources, made up a prototype analyzing system from this design study, and then evaluated its availability. As a result, we obtained the following: (1) A new dose evaluation method was established to predict the radiation dose rate at any point in the plant during a severe accident scenario. (2) This evaluation of total dose including access route and time for emergency activities is useful for estimating radiation dose limit for these employee actions. (3) The radiation dose rate map is effective for identifying high radiation areas and for choosing a route with lower radiation dose rate. (author)

  12. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Habiballah, B.; Abdelaziz, I.; Alzimami, K.; Osman, H.; Omer, H.; Sassi, S. A.

    2014-08-01

    Orthopedists are exposed to considerable radiation dose during orthopedic surgeries procedures. The staff is not well trained in radiation protection aspects and its related risks. In Sudan, regular monitoring services are not provided for all staff in radiology or interventional personnel. It is mandatory to measure staff and patient exposure in order to radiology departments. The main objectives of this study are: to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (Dhs) and (i i) Dynamic Cannula Screw (Dcs); to estimate the risk of the aforementioned procedures and to evaluate entrance surface dose (ESD) and organ dose to specific radiosensitive patients organs. The measurements were performed in Medical Corps Hospital, Sudan. The dose was measured for unprotected organs of staff and patient as well as scattering radiation. Calibrated Thermoluminescence dosimeters (TLD-Gr-200) of lithium fluoride (LiF:Mg, Cu,P) were used for ESD measurements. TLD signal are obtained using automatic TLD Reader model (Plc-3). The mean patients doses were 0.46 mGy and 0.07 for Dhs and Dcs procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean radiation dose for staff was higher in Dhs compared to Dcs. This can be attributed to the long fluoroscopic exposures due to the complication of the procedures. Efforts should be made to reduce radiation exposure to orthopedic patients, and operating surgeons especially those with high work load. Staff training and regular monitoring will reduce the radiation dose for both patients and staff. (Author)

  13. Evaluation of occupational and patient radiation doses in orthopedic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Sulieman, A. [Salman bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P.O. Box 422, Alkharj (Saudi Arabia); Habiballah, B.; Abdelaziz, I. [Sudan Univesity of Science and Technology, College of Medical Radiologic Sciences, P.O. Box 1908, Khartoum (Sudan); Alzimami, K. [King Saud University, College of Applied Medical Sciences, Radiological Sciences Department, P.O. Box 10219, 11433 Riyadh (Saudi Arabia); Osman, H. [Taif University, College of Applied Medical Science, Radiology Department, Taif (Saudi Arabia); Omer, H. [University of Dammam, Faculty of Medicine, Dammam (Saudi Arabia); Sassi, S. A., E-mail: Abdelmoneim_a@yahoo.com [Prince Sultan Medical City, Department of Medical Physics, Riyadh (Saudi Arabia)

    2014-08-15

    Orthopedists are exposed to considerable radiation dose during orthopedic surgeries procedures. The staff is not well trained in radiation protection aspects and its related risks. In Sudan, regular monitoring services are not provided for all staff in radiology or interventional personnel. It is mandatory to measure staff and patient exposure in order to radiology departments. The main objectives of this study are: to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (Dhs) and (i i) Dynamic Cannula Screw (Dcs); to estimate the risk of the aforementioned procedures and to evaluate entrance surface dose (ESD) and organ dose to specific radiosensitive patients organs. The measurements were performed in Medical Corps Hospital, Sudan. The dose was measured for unprotected organs of staff and patient as well as scattering radiation. Calibrated Thermoluminescence dosimeters (TLD-Gr-200) of lithium fluoride (LiF:Mg, Cu,P) were used for ESD measurements. TLD signal are obtained using automatic TLD Reader model (Plc-3). The mean patients doses were 0.46 mGy and 0.07 for Dhs and Dcs procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean radiation dose for staff was higher in Dhs compared to Dcs. This can be attributed to the long fluoroscopic exposures due to the complication of the procedures. Efforts should be made to reduce radiation exposure to orthopedic patients, and operating surgeons especially those with high work load. Staff training and regular monitoring will reduce the radiation dose for both patients and staff. (Author)

  14. Principles of protection: a formal approach for evaluating dose distributions

    International Nuclear Information System (INIS)

    Wikman-Svahn, Per; Peterson, Martin; Hansson, Sven Ove

    2006-01-01

    One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties

  15. Comparison of the dose evaluation methods for criticality accident

    International Nuclear Information System (INIS)

    Shimizu, Yoshio; Oka, Tsutomu

    2004-01-01

    The improvement of the dose evaluation method for criticality accidents is important to rationalize design of the nuclear fuel cycle facilities. The source spectrums of neutron and gamma ray of a criticality accident depend on the condition of the source, its materials, moderation, density and so on. The comparison of the dose evaluation methods for a criticality accident is made. Some methods, which are combination of criticality calculation and shielding calculation, are proposed. Prompt neutron and gamma ray doses from nuclear criticality of some uranium systems have been evaluated as the Nuclear Criticality Slide Rule. The uranium metal source (unmoderated system) and the uranyl nitrate solution source (moderated system) in the rule are evaluated by some calculation methods, which are combinations of code and cross section library, as follows: (a) SAS1X (ENDF/B-IV), (b) MCNP4C (ENDF/B-VI)-ANISN (DLC23E or JSD120), (c) MCNP4C-MCNP4C (ENDF/B-VI). They have consisted of criticality calculation and shielding calculation. These calculation methods are compared about the tissue absorbed dose and the spectrums at 2 m from the source. (author)

  16. Field study to evaluate radiation doses in dental practices

    International Nuclear Information System (INIS)

    Panzer, W.; Scheurer, C.

    1984-05-01

    An inexpensive and simple test device was developed and used in a field study to evaluate entrance dose, dose to an intra-oral film, filtration and field size under routine conditions in more than 150 dental practices. The test device consists of two films of different speed and a set of 5 thin copper filters for a filter analytical determination of the radiation quality. Dentists voluntarily participating in the study were asked to expose the test device like they usually do when examining a molar tooth. The main result was the evidence of a significant dose reduction compared to the findings of similar studies performed in 1970 and 1976. This reduction is due to a general shift to lower values and a complete disappearance of values above 45 mGy (5 R) which in 1970 were still more than 15%. In the same way the number of facilities showing insufficient filtration or collimation had decreased. Nevertheless, a large spread of dose values could still be observed, ranging from less than 0.45 mGy (50 mR) to more than 26 mGy (3 R), for the entrance dose. The most striking result, however, was that such an important parameter like the speed of the films used at the respective unit turned out to have no impact on the entrance dose. (orig./HP)

  17. In vivo evaluation of the antimutagenic and antigenotoxic effects of β-glucan extracted from Saccharomyces cerevisiae in acute treatment with multiple doses

    Directory of Open Access Journals (Sweden)

    Rodrigo Juliano Oliveira

    2013-01-01

    Full Text Available Ample evidence suggests that cancer is triggered by mutagenic damage and diets or supplements capable of reducing such incidences can be related to the prevention of neoplasy development or to an improvement in life quality of patients who undergo chemotherapy. This research aimed to evaluate the antimutagenic and antigenotoxic activity of β-glucan. We set up 8 experimental groups: control (Group 1, cyclophosphamide (Group 2, Groups 3-5 to assess the effect of β-glucan administration, and Groups 6-8 to evaluate the association between cyclophosphamide and β-glucan. The intraperitonial concentrations of β-glucan used were 100, 150 and 200 mg/kg. Micronucleus and comet assays showed that within the first week of treatment β-glucan presented a damage reduction rate between 100-62.04% and 94.34-59.52% for mutagenic and genotoxic damages, respectively. This activity decreased as the treatment was extended. During the sixth week of treatment antimutagenicity rates were reduced to 59.51-39.83% and antigenotoxicity was not effective. This leads to the conclusion that the efficacy of β-glucan in preventing DNA damage is limited when treatment is extended, and that its use as a chemotherapeutic adjuvant need to be better clarified.

  18. Evaluation of effectiveness of a computer system (CAD) in the identification of lung nodules with low-dose MSCT: scanning technique and preliminary results

    International Nuclear Information System (INIS)

    Fraioli, Francesco; Catalano, Carlo; Almberger, Maria; Bertoletti, Linda; Cantisani, Vito; Danti, Massimiliano; Pediconi, Federica; Passariello, Roberto

    2005-01-01

    Purpose: Evaluation of the effectiveness of a computer-aided diagnosis (CAD) in the identification of pulmonary nodules. Materials and methods: Two observers (A1, A2) with different levels of experience independently evaluated 20 chest MSCT studies with and without the aid of a CAD system (LungCheck, R2 Technology, Inc.). The study parameters were as follows: 140 kVs, 40 mAs, collimation 4x1 mm, slice thickness 1.25 mm, reconstruction interval 1.0 mm. The observers analysed the images with and without CAD and evaluated: 1) nodule size (longer axis); 2) number and location of nodules; 3) reading time for each observer. The gold standard was represented by the evaluation of both readers in consensus with the aid of the CAD system. Results: Without CAD support the two readers identified 77 (A1) and 79 (A2) nodules and with CAD 81 (A1) and 82 (A2) nodules. Working in consensus the two observers identified 81 nodules without the aid of CAD and 84 nodules with the aid of CAD. Total number of nodules identified by CAD was 104, 25 of which were false positive and 5 false negative. The average reading time with the aid of CAD decreased by as much as 40% for both the observers. Conclusions: The preliminary results of our study suggest that the CAD technique is an accurate automatic support tool in the identification of pulmonary nodules. It reduces reading time and automatically supplies the size, volume, density and number of nodules, thus being useful both in screening programmes and in the follow-up of cancer patients, in whom comparison of the images is particularly difficult [it

  19. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  20. The Effect of Aquaplast on Surface Dose of Photon Beam

    International Nuclear Information System (INIS)

    Oh, Do Hoon; Bae, Hoon Sik

    1995-01-01

    Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy. Materials and Methods : To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in 25 X 25 X 3 cm 3 acrylic phantom and set on 25 X 25 X 5 cm 3 , polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 10 cm SSD for 5 X 5 cm 2 , 10 X 10 cm 2 , and 15 X 15 cm 2 field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types o Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and khan to correct over response of the Markus chamber. Results : The surface doses for open fields of 5 X 5 cm 2 , 10 X 10 cm 2 , 15 X 15 cm 2 were 7.9%, 13.6%, and 18.7% respectively. He original Aquaplast increased the surface doses upto 38.4%, 43.6% and 47.4% respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by 0.2%, 1.7%, 3.0% without Aquaplast, 0.2%, 1.9%, 3.7% with transformed Aquaplast, respectively. Conclusion : The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax

  1. Standard effective doses for proliferative tumours

    International Nuclear Information System (INIS)

    Jones, L.C.; Hoban, P.

    1999-01-01

    This study was undertaken to investigate the treatment schedules used clinically for highly proliferative tumours, particularly with reference to the effects of fraction size, fraction number and treatment duration. The linear quadratic model (with time component) is used here to compare non-standard treatment regimens (e.g. accelerated and hyperfractionated schedules), currently the focus of randomized trials, with each other and some common 'standard regimens'. To ensure easy interpretation of results, two parameters known as proliferative standard effective dose one (PSED 1 ) and proliferative standard effective dose two (PSED 2 ) have been calculated for each regimen. Graphs of PSED 1 and PSED 2 versus potential doubling time (T p ) have been generated for a range of fractionation regimens which are currently under trial in various randomized studies. From these graphs it can be seen that the highly accelerated schedules (such as CHART) only show advantages for tumours with very short potential doubling times. Calculations for most of the schedules considered showed at least equivalent tumour control expected for the trial schedule compared with the control arm used and these values agree quite well with clinical results. These calculations are in good agreement with clinical results available at present. The greater the PSED 1 or PSED 2 for the schedule considered the greater the tumour control, which can be expected. However, as has been seen with clinical trials, this higher cell kill also results in higher acute effects which have proved too great for some accelerated schedules to continue. (author)

  2. SU-G-BRC-08: Evaluation of Dose Mass Histogram as a More Representative Dose Description Method Than Dose Volume Histogram in Lung Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Liu, J; Eldib, A; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Lin, M [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States); Li, J [Cyber Medical Inc, Xian, Shaanxi (China); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal)

    2016-06-15

    Purpose: Dose-volume-histogram (DVH) is widely used for plan evaluation in radiation treatment. The concept of dose-mass-histogram (DMH) is expected to provide a more representative description as it accounts for heterogeneity in tissue density. This study is intended to assess the difference between DVH and DMH for evaluating treatment planning quality. Methods: 12 lung cancer treatment plans were exported from the treatment planning system. DVHs for the planning target volume (PTV), the normal lung and other structures of interest were calculated. DMHs were calculated in a similar way as DVHs expect that the voxel density converted from the CT number was used in tallying the dose histogram bins. The equivalent uniform dose (EUD) was calculated based on voxel volume and mass, respectively. The normal tissue complication probability (NTCP) in relation to the EUD was calculated for the normal lung to provide quantitative comparison of DVHs and DMHs for evaluating the radiobiological effect. Results: Large differences were observed between DVHs and DMHs for lungs and PTVs. For PTVs with dense tumor cores, DMHs are higher than DVHs due to larger mass weighing in the high dose conformal core regions. For the normal lungs, DMHs can either be higher or lower than DVHs depending on the target location within the lung. When the target is close to the lower lung, DMHs show higher values than DVHs because the lower lung has higher density than the central portion or the upper lung. DMHs are lower than DVHs for targets in the upper lung. The calculated NTCPs showed a large range of difference between DVHs and DMHs. Conclusion: The heterogeneity of lung can be well considered using DMH for evaluating target coverage and normal lung pneumonitis. Further studies are warranted to quantify the benefits of DMH over DVH for plan quality evaluation.

  3. Age-dependent conversion coefficients for organ doses and effective doses for external neutron irradiation

    International Nuclear Information System (INIS)

    Nishizaki, Chihiro; Endo, Akira; Takahashi, Fumiaki

    2006-06-01

    To utilize dose assessment of the public for external neutron irradiation, conversion coefficients of absorbed doses of organs and effective doses were calculated using the numerical simulation technique for six different ages (adult, 15, 10, 5 and 1 years and newborn), which represent the member of the public. Calculations were performed using six age-specific anthropomorphic phantoms and a Monte Carlo radiation transport code for two irradiation geometries, anterior-posterior and rotational geometries, for 20 incident energies from thermal to 20 MeV. Effective doses defined by the 1990 Recommendation of ICRP were calculated from the absorbed doses in 21 organs. The calculated results were tabulated in the form of absorbed doses and effective doses per unit neutron fluence. The calculated conversion coefficients are used for dose assessment of the public around nuclear facilities and accelerator facilities. (author)

  4. Effect of dose and dose rate of gamma radiation on catalytic activity of catalase

    International Nuclear Information System (INIS)

    Vaclav Cuba; Tereza Pavelkova; Viliam Mucka

    2010-01-01

    Catalytic activity of gamma irradiated catalase from bovine liver was studied for hydrogen peroxide decomposition at constant temperature and pressure. The measurement was performed at temperatures 27, 32, 37, 42 and 47 deg C. Solutions containing 1 and 0.01 g dm -3 of catalase in phosphate buffer were used for the study. Repeatability of both sample preparation and kinetics measurement was experimentally verified. Rate constants of the reaction were determined for all temperatures and the activation energy was evaluated from Arrhenius plot. Gamma irradiation was performed using 60 Co radionuclide source Gammacell 220 at two different dose rates 5.5 and 70 Gy h -1 , with doses ranging from 10 to 1000 Gy. The observed reaction of irradiated and non-irradiated catalase with hydrogen peroxide is of the first order. Irradiation significantly decreases catalytic activity of catalase, but the activation energy does not depend markedly on the dose. The effect of irradiation is more significant at higher dose rate. (author)

  5. Effective dose rate coefficients for exposure to contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States); Bellamy, M.B.; Hiller, M.M.; Dewji, S.A. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Hertel, N.E. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Georgia Institute of Technology, Atlanta, GA (United States); Manger, R. [University of California San Diego, Department of Radiation Medicine and Applied Sciences, La Jolla, CA (United States)

    2017-08-15

    The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios. (orig.)

  6. Two gamma dose evaluation methods for silicon semiconductor detector

    International Nuclear Information System (INIS)

    Chen Faguo; Jin Gen; Yang Yapeng; Xu Yuan

    2011-01-01

    Silicon PIN diodes have been widely used as personal and areal dosimeters because of their small volume, simplicity and real-time operation. However, because silicon is neither a tissue-equivalent nor an air-equivalent material, an intrinsic disadvantage for silicon dosimeters is that a significant over-response occurs at low-energy region, especially below 200 keV. Using a energy compensation filter to flatten the energy response is one method overcoming this disadvantage. But for dose compensation method, the estimated dose depends only on the number of the detector pulses. So a weight function method was introduced to evaluate gamma dose, which depends on pulse number as well as its amplitude. (authors)

  7. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  8. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  9. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  10. Reduced biological effect of e-cigarette aerosol compared to cigarette smoke evaluated in vitro using normalized nicotine dose and RNA-seq-based toxicogenomics

    OpenAIRE

    Haswell, Linsey E.; Baxter, Andrew; Banerjee, Anisha; Verrastro, Ivan; Mushonganono, Jessica; Adamson, Jason; Thorne, David; Ga?a, Marianna; Minet, Emmanuel

    2017-01-01

    Electronic cigarettes (e-cigarettes) use has increased globally and could potentially offer a lower risk alternative to cigarette smoking. Here, we assessed the transcriptional response of a primary 3D airway model acutely exposed to e-cigarette aerosol and cigarette (3R4F) smoke. Aerosols were generated with standard intense smoking regimens with careful consideration for dose by normalizing the exposures to nicotine. Two e-cigarette aerosol dilutions were tested for equivalent and higher ni...

  11. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  12. Evaluation of dose delivered to critical organs during pituitary radiation therapy

    International Nuclear Information System (INIS)

    Awoda, Marwa Elrashied Mohammed

    2017-12-01

    The selection of an appropriate energy in radiation therapy for tumor and the delivery adequate dose to the tumors to be treated, is very important during the radiation treatment planning. Also the dose received to critical organs surrounding the tumor has be considered. In addition, validation of treatment plan quality is important, so the purpose of this study was to evaluate the effect of teletherapy cobalt and 6MV linac energies on dose distribution for the pituitary gland tumors and dose delivered to critical organs surrounding the tumor. 10 patients with pituitary adenocarcinomas were selected. For treatment plans with three field technique, verdes and two lateral fields, were used. For the therapeutic area, five organs left and right eye lens left and right optic never and chasms and brain stem, were considered as Organ at risk (OARS). Several physical indices for for planning target volume (PTV) and the organs at risk 9 (OARS) as means dose (MD). 95%, dose (D950), 5% dose (D5) and normal tissue dose (NTID), were calculated, and the homogeneity index and conformity index were also two other evaluation parameters have been taken into account. The comparative evaluation was based on dose volume histogram ( DVH) analysis for both energies plans. After performing the treatment planning with two different energies the dose received to critical organs and dose distribution in PTV were studied. Results showed that the difference between the integral dose received to OARs with Co-60 and 6-MV linac respectively, 2.16±1.48, 1.85±1.55 for Lt eye lens. 3.01±2.52, 1.89±2.09 for Rt eye lens, 18.5±10.97, 19.43±10.65 for Lt optic nerve and chasms, 15.86±11.30, 17.44±15.73 for Rt optic nerve and chasms and 24.03±13.68, 23.77±16.64 for Brain stem case showed higher integral dose for linac than Co-60 than due to using the 6-MV energy as an open field with no beam modifiers such MLCs or shielding blocks. Eventually, it found that using of 6-MV linac provides better

  13. Idaho National Engineering Laboratory historical dose evaluation: Volume 1

    International Nuclear Information System (INIS)

    Francis, S.J.

    1991-08-01

    The methodology and results are presented for an evaluation of potential radiation doses to a hypothetical individual who may have resided at an offsite location with the highest concentration of airborne radionuclides near the Idaho National Engineering Laboratory (INEL). Volume 1 contains a summary of methods and results. The years of INEL operations from 1952 to 1989 were evaluated. Radiation doses to an adult, child, and infant were estimated for both operational (annual) and episodic (short-term) airborne releases from INEL facilities. Atmospheric dispersion of operational releases was modeled using annual average meteorological conditions. Dispersion of episodic releases was generally modeled using actual hourly wind speed and direction data at the time of release. 50 refs., 23 figs., 10 tabs

  14. Committed effective dose determination in southern Brazilian cereal flours.

    Science.gov (United States)

    Scheibel, V; Appoloni, C R

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of (228)Th, (228)Ra, (226)Ra, (40)K, (7)Be and (137)Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of (228)Th and (40)K were 3.5±0.4 and 1469±17 Bq kg(-1) for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for (137)Cs ranged from 0.04 to 0.4 Bq kg(-1). The highest committed effective dose was 0.36 μSv.y(-1) for (228)Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y(-1), to the public exposure.

  15. Committed effective dose determination in southern Brazilian cereal flours

    International Nuclear Information System (INIS)

    Scheibel, V.; Appoloni, C. R.

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of 228 Th, 228 Ra, 226 Ra, 40 K, 7 Be and 137 Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of 228 Th and 40 K were 3.5±0.4 and 1469±17 Bq kg -1 for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for 137 Cs ranged from 0.04 to 0.4 Bq kg -1 . The highest committed effective dose was 0.36 μSv.y -1 for 228 Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y -1 , to the public exposure. (authors)

  16. Evaluation of environmental radiation dose in Ibaraki Prefecture

    International Nuclear Information System (INIS)

    Koike, Ryoji

    1977-01-01

    In Ibaraki Prefecture, there is Environmental Radioactivity Surveillance Committee in order to ensure the safety around nuclear power facilities. Environmental radioactivity data are collected every three months, and the grasp of the present situation, the clarification of causes, the evaluation of dose and the publication of results are made. Two instances in particular are described: of contamination paddies due to 14 C contained in drainage; contamination of rivers due to U contained in drainage. (Mori, K.)

  17. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  18. Evaluation of occupational dose from the special procedures guided by fluoroscopy: cardiac catheterism

    International Nuclear Information System (INIS)

    Silva, Amanda Juliene da

    2011-01-01

    The purpose of this study was to evaluate the dose received by health professionals in the hemodynamic sector of a university hospital in Sao Paulo city. A self-applied questionnaire was used to delineate the profile of health professionals, taking into account sociodemographic variables and variables related to the work with ionizing radiation. The assessment of occupational doses was performed by consulting of the individual dose records of the institution database from 2000 to 2009. A total of 240 records was evaluated, corresponding to 38 active professionals (2009), divided in different professional category: physician, nurses, radiologic technologists and nursing assistants. The annual doses were compared with the limits established by national regulatory authorities. Based on the effective doses received and recorded during the studied period, experimental measures were performed with TL dosimeters in five physicians to evaluate the equivalent dose, in the left hand, during hemodynamic procedures. In addition, the radioprotection measures adopted by health professionals were verified. This study allowed delineating the profile of medical staff that integrates the hemodynamic service as well as knowing the distribution of their doses in relation to limits over the years. (author)

  19. Evaluation of dose according to the volume and respiratory range during SBRT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deuk Hee [Dept. of Radiation Oncology, Busan Paik Hospital, Inje University, Busan (Korea, Republic of); Park, Eun Tae; Kim, Jung Hoon; Kang, Se Seik [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2016-09-15

    Stereotactic body radiotherapy is effective technic in radiotherapy for low stage lung cancer. But lung cancer is affected by respiratory so accurately concentrate high dose to the target is very difficult. In this study, evaluated the target volume according to how to take the image. And evaluated the dose by photoluminescence glass dosimeter according to how to contour the volume and respiratory range. As a result, evaluated the 4D CT volume was 10.4 cm{sup 3} which was closest value of real size target. And in dose case is internal target volume dose was 10.82, 16.88, 21.90 Gy when prescribed dose was 10, 15, 20 Gy and it was the highest dose. Respiratory gated radiotherapy dose was more higher than internal target volume. But it made little difference by respiratory range. Therefore, when moving cancer treatment, acquiring image by 4D CT, contouring internal target volume and respiratory gated radiotherapy technic would be the best way.

  20. Evaluation of dose according to the volume and respiratory range during SBRT in lung cancer

    International Nuclear Information System (INIS)

    Lee, Deuk Hee; Park, Eun Tae; Kim, Jung Hoon; Kang, Se Seik

    2016-01-01

    Stereotactic body radiotherapy is effective technic in radiotherapy for low stage lung cancer. But lung cancer is affected by respiratory so accurately concentrate high dose to the target is very difficult. In this study, evaluated the target volume according to how to take the image. And evaluated the dose by photoluminescence glass dosimeter according to how to contour the volume and respiratory range. As a result, evaluated the 4D CT volume was 10.4 cm 3 which was closest value of real size target. And in dose case is internal target volume dose was 10.82, 16.88, 21.90 Gy when prescribed dose was 10, 15, 20 Gy and it was the highest dose. Respiratory gated radiotherapy dose was more higher than internal target volume. But it made little difference by respiratory range. Therefore, when moving cancer treatment, acquiring image by 4D CT, contouring internal target volume and respiratory gated radiotherapy technic would be the best way

  1. Low doses effects and gamma radiations low dose rates; Les effets des faibles doses et des faibles debits de doses de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Averbeck, D [Institut Curie, CNRS UMR 2027, 75 - Paris (France)

    1999-07-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  2. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  3. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  4. Robust ray-tracing algorithms for interactive dose rate evaluation

    International Nuclear Information System (INIS)

    Perrotte, L.

    2011-01-01

    More than ever, it is essential today to develop simulation tools to rapidly evaluate the dose rate received by operators working on nuclear sites. In order to easily study numerous different scenarios of intervention, computation times of available softwares have to be all lowered. This mainly implies to accelerate the geometrical computations needed for the dose rate evaluation. These computations consist in finding and sorting the whole list of intersections between a big 3D scene and multiple groups of 'radiative' rays meeting at the point where the dose has to be measured. In order to perform all these computations in less than a second, we first propose a GPU algorithm that enables the efficient management of one big group of coherent rays. Then we present a modification of this algorithm that guarantees the robustness of the ray-triangle intersection tests through the elimination of the precision issues due to floating-point arithmetic. This modification does not require the definition of scene-dependent coefficients ('epsilon' style) and only implies a small loss of performance (less than 10%). Finally we propose an efficient strategy to handle multiple ray groups (corresponding to multiple radiative objects) which use the previous results.Thanks to these improvements, we are able to perform an interactive and robust dose rate evaluation on big 3D scenes: all of the intersections (more than 13 million) between 700 000 triangles and 12 groups of 100 000 rays each are found, sorted along each ray and transferred to the CPU in 470 milliseconds. (author) [fr

  5. Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Sumida, Iori, E-mail: sumida@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Yamaguchi, Hajime; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yoshikawa, Nobuhiko; Yamada, Yuji [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Suzuki, Osamu; Seo, Yuji [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Isohashi, Fumiaki [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Yoshioka, Yasuo [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Ogawa, Kazuhiko [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan)

    2015-07-15

    Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV, spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.

  6. Review of low dose-rate epidemiological studies and biological mechanisms of dose-rate effects on radiation induced carcinogenesis

    International Nuclear Information System (INIS)

    Iwasaki, Toshiyasu; Otsuka, Kensuke; Yoshida, Kazuo

    2015-01-01

    Radiation protection system adopts the linear non-threshold model with using dose and dose-rate effectiveness factor (DDREF). The dose-rate range where DDREF is applied is below 100 mGy per hour, and it is regarded that there are no dose-rate effects at very low dose rate, less than of the order of 10 mGy per year, even from the biological risk evaluation model based on cellular and molecular level mechanisms for maintenance of genetic integrity. Among low dose-rate epidemiological studies, studies of residents in high natural background areas showed no increase of cancer risks at less than about 10 mGy per year. On the other hand, some studies include a study of the Techa River cohort suggested the increase of cancer risks to the similar degree of Atomic bomb survivor data. The difference of those results was supposed due to the difference of dose rate. In 2014, International Commission on Radiological Protection opened a draft report on stem cell biology for public consultations. The report proposed a hypothesis based on the new idea of stem cell competition as a tissue level quality control mechanism, and suggested that it could explain the dose-rate effects around a few milligray per year. To verify this hypothesis, it would be needed to clarify the existence and the lowest dose of radiation-induced stem cell competition, and to elucidate the rate of stem cell turnover and radiation effects on it. As for the turnover, replenishment of damaged stem cells would be the important biological process. It would be meaningful to collect the information to show the difference of dose rates where the competition and the replenishment would be the predominant processes. (author)

  7. Evaluating the maximum patient radiation dose in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, M.; Chida, K.; Sato, T.; Oosaka, H.; Tosa, T.; Kadowaki, K.

    2011-01-01

    Many of the X-ray systems that are used for cardiac interventional radiology provide no way to evaluate the patient maximum skin dose (MSD). The authors report a new method for evaluating the MSD by using the cumulative patient entrance skin dose (ESD), which includes a back-scatter factor and the number of cine-angiography frames during percutaneous coronary intervention (PCI). Four hundred consecutive PCI patients (315 men and 85 women) were studied. The correlation between the cumulative ESD and number of cine-angiography frames was investigated. The irradiation and overlapping fields were verified using dose-mapping software. A good correlation was found between the cumulative ESD and the number of cine-angiography frames. The MSD could be estimated using the proportion of cine-angiography frames used for the main angle of view relative to the total number of cine-angiography frames and multiplying this by the cumulative ESD. The average MSD (3.0±1.9 Gy) was lower than the average cumulative ESD (4.6±2.6 Gy). This method is an easy way to estimate the MSD during PCI. (authors)

  8. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  9. Study of hard X-ray dose enhancement effects for some kinds of semiconductor devices

    CERN Document Server

    Guo Hong Xia; Chen Yu Sheng; Zhou Hui; He Chao Hui; Xie Ya Ning; Huang Yu Ying; He Wei; Hu Tian Dou

    2002-01-01

    Experimental results of X-ray dose enhancement effects are given for CMOS4069 and floating gate ROMs irradiated in Beijing Synchrotron Radiation Facility and in cobalt source. Shift of threshold voltage vs. total dose for CMOS4069 and the errors vs. total dose for 28f256 and 29c256 have been tested on line and the equivalent relation of total dose damage under the same accumulated dose is provided comparing the response of devices irradiated by X-ray and gamma-ray source. These results can be provided for X-ray radiation hardening technology as an effective evaluation data

  10. Characteristics of natural background external radiation and effective dose equivalent

    International Nuclear Information System (INIS)

    Fujimoto, Kenzo

    1989-01-01

    The two sources of natural radiation - cosmic rays and primordial radionuclides - are described. The factors affecting radiation doses received from natural radiation and the calculation of effective dose equivalent due to natural radiation are discussed. 10 figs., 3 tabs

  11. Evaluation of a low-dose neonatal chest radiographic system

    International Nuclear Information System (INIS)

    Burton, E.M.; Kirks, D.R.; Strife, J.L.; Henry, G.C.; Kereiakes, J.G.

    1988-01-01

    A new low-dose chest radiographic system for use in the neonatal nursery was evaluated. This test system, composed of a Du Pont Kevlar fiber-front cassette, Quanta fast-detail screen, Cronex 4L film (wide latitude), and additional yttrium filtration (0.1 mm), reduced the radiation dose in neonatal chest radiography by 69% (0.9 vs 2.9 mrad [0.009 vs 0.029 mGy]) as compared with a conventional system without added yttrium filtration; the thyroid dose was reduced by 76% (0.9 vs 3.7 mrad [0.009 vs 0.037 mGy]). The cumulative dose reduction was achieved through a combination of factors, including (1) beam hardening by the added yttrium filter, (2) increased X-ray transmission through the Kevlar cassette, and (3) a fast film-screen combination. Scatter radiation at distances of 1 and 6 ft. (0.3 and 1.8 m) was negligible for both systems. Image sharpness was compared for the conventional system with and without added yttrium filtration and for the Kevlar system with yttrium. Although sharpness of bony detail was unchanged by adding yttrium filtration to the conventional system, a decrease in sharpness was noted with the Kevlar system. Because image sharpness was affected in the test system, we are not using the Kevlar-Cronex 4L system for mobile chest radiography in the neonatal intensive care unit, despite dose reductions. However, further study is recommended to determine if there is a slower film-screen combination with yttrium filtration that will not degrade image sharpness

  12. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.

    Science.gov (United States)

    Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M

    2010-12-01

    The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.

  13. Application of accelerated evaluation method of alteration temperature and constant dose rate irradiation on bipolar linear regulator LM317

    International Nuclear Information System (INIS)

    Deng Wei; Wu Xue; Wang Xin; Zhang Jinxin; Zhang Xiaofu; Zheng Qiwen; Ma Wuying; Lu Wu; Guo Qi; He Chengfa

    2014-01-01

    With different irradiation methods including high dose rate irradiation, low dose rate irradiation, alteration temperature and constant dose rate irradiation, and US military standard constant high temperature and constant dose rate irradiation, the ionizing radiation responses of bipolar linear regulator LM317 from three different companies were investigated under the operating and zero biases. The results show that compared with constant high temperature and constant dose rate irradiation method, the alteration temperature and constant dose rate irradiation method can not only very rapidly and accurately evaluate the dose rate effect of three bipolar linear regulators, but also well simulate the damage of low dose rate irradiation. Experiment results make the alteration temperature and constant dose rate irradiation method successfully apply to bipolar linear regulator. (authors)

  14. Dose rate effect models for biological reaction to ionizing radiation in human cell lines

    International Nuclear Information System (INIS)

    Magae, Junji; Ogata, Hiromitsu

    2008-01-01

    Full text: Because of biological responses to ionizing radiation are dependent on irradiation time or dose rate as well as dose, simultaneous inclusion of dose and dose rate is required to evaluate the risk of long term irradiation at low dose rates. We previously published a novel statistical model for dose rate effect, modified exponential (MOE) model, which predicts irradiation time-dependent biological response to low dose rate ionizing radiation, by analyzing micronucleus formation and growth inhibition in a human osteosarcoma cell line, exposed to wide range of doses and dose rates of gamma-rays. MOE model demonstrates that logarithm of median effective dose exponentially increases in low dose rates, and thus suggests that the risk approaches to zero at infinitely low dose rate. In this paper, we extend the analysis in various kinds of human cell lines exposed to ionizing radiation for more than a year. We measured micronucleus formation and [ 3 H]thymidine uptake in human cell lines including an osteosarcoma, a DNA-dependent protein kinase-deficient glioma, a SV40-transformed fibroblast derived from an ataxia telangiectasia patient, a normal fibroblast, and leukemia cell lines. Cells were exposed to gamma-rays in irradiation room bearing 50,000 Ci of cobalt-60. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, and cytoplasm and nucleus were stained with DAPI and prospidium iodide. The number of binuclear cells bearing a micronucleus was counted under a fluorescence microscope. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [ 3 H] thymidine was pulsed for 4 h before harvesting. We statistically analyzed the data for quantitative evaluation of radiation risk. While dose and dose rate relationship cultured within one month followed MOE model in cell lines holding wild-type DNA repair system, dose rate effect was greatly impaired in DNA repair-deficient cell lines

  15. Comments on 'Standard effective doses for proliferative tumours'

    International Nuclear Information System (INIS)

    Dasu, Iuliana Livia; Dasu, Alexandru; Denekamp, Juliana; Fowler, Jack F.

    2000-01-01

    We should like to make some comments on the paper published by Jones et al (1999). The paper presents some interesting and useful contributions on the theoretical evaluation of different fractionated schedules used now. The use of the linear quadratic equation has been very useful in focusing attention on the differences in fractionation responses of fast and slow proliferating normal tissues and tumours. Unfortunately the BED 10 or BED 3 units for (α/β ratios of 10 Gy and 3 Gy respectively) do not directly relate to anything used in routine clinical practice. The purpose of the paper by Jones et al (1999) is to covert any new schedule into the equivalent total dose as if it was given in the same size fractions as are in common use in that department. They illustrate that, if proliferation is taken into account for the altered schedule, it can be compared in two ways with the standard conventional schedule: (a) the proliferative standard effective dose one (PSED 1 ) in which the proliferation correction is applied in the altered schedule, but not in the standard schedule; (b) the proliferative standard effective dose two (PSED 2 ) in which the proliferation correction is applied to both schedules using the same proliferation parameters. This is expected to provide a better evaluation of the response of a 'real' tumour (i.e. a tumour that also proliferates during the standard treatment). However, there seem to be two errors in the paper. First, the authors quoted a wrong equation for calculating the proliferative standard effective dose two (PSED 2 ) (equations (2) and (A6) in their paper). There are also some special cases with respect to the time available for proliferation and the duration of the treatment that have been neglected in their paper and which require further specification. Therefore, we should like to give the full mathematical derivation of the correct equations for calculating the proliferative standard effective doses. We would also like to make

  16. Dose Evaluation and Quality Criteria in Dental Radiology

    International Nuclear Information System (INIS)

    Gori, C.; Rossi, F.; Stecco, A.; Villari, N.; Zatelli, G.

    2000-01-01

    Radioprotection in dental radiology is of particular interest in the framework of the Revised Medical Exposure Directive for the great number of examinations involving the adult as well as the paediatric population (Article 9: Special Practice). The present study is intended to find the quality criteria of orthodontic imaging and for evaluating the dose absorbed within the dental and maxillary volume in connection with radiological examinations performed with either spiral CT, dental panoramic tomography or teleradiography. The X ray dose to organs sited in the body, neck, ocular and intracranial area was measured using lithium fluoride dosemeters, positioned in a Rando phantom. Quality criteria have been established by an expert radiologist considering the diagnostic information obtained in the images. The dosimetric data obtained were comparable with other authors', although with some differences due to technical characteristics. These result data are useful for choosing the patient's diagnostic path, considering the radiobiological risk associated with increasing orthodontic imaging. (author)

  17. Does iterative reconstruction lower CT radiation dose: evaluation of 15,000 examinations.

    Directory of Open Access Journals (Sweden)

    Peter B Noël

    Full Text Available PURPOSE: Evaluation of 15,000 computed tomography (CT examinations to investigate if iterative reconstruction (IR reduces sustainably radiation exposure. METHOD AND MATERIALS: Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. RESULTS: IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01. Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv, or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv the dose reduction effect is significant(p*=0.01. On the contrary for unenhanced low-dose scans of the cranial (for example sinuses the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv. CONCLUSION: The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine

  18. Radiation dose evaluation of dental cone beam computed tomography using an anthropomorphic adult head phantom

    Science.gov (United States)

    Wu, Jay; Shih, Cheng-Ting; Ho, Chang-hung; Liu, Yan-Lin; Chang, Yuan-Jen; Min Chao, Max; Hsu, Jui-Ting

    2014-11-01

    Dental cone beam computed tomography (CBCT) provides high-resolution tomographic images and has been gradually used in clinical practice. Thus, it is important to examine the amount of radiation dose resulting from dental CBCT examinations. In this study, we developed an in-house anthropomorphic adult head phantom to evaluate the level of effective dose. The anthropomorphic phantom was made of acrylic and filled with plaster to replace the bony tissue. The contour of the head was extracted from a set of adult computed tomography (CT) images. Different combinations of the scanning parameters of CBCT were applied. Thermoluminescent dosimeters (TLDs) were used to measure the absorbed doses at 19 locations in the head and neck regions. The effective doses measured using the proposed phantom at 65, 75, and 85 kVp in the D-mode were 72.23, 100.31, and 134.29 μSv, respectively. In the I-mode, the effective doses were 108.24, 190.99, and 246.48 μSv, respectively. The maximum percent error between the doses measured by the proposed phantom and the Rando phantom was l4.90%. Therefore, the proposed anthropomorphic adult head phantom is applicable for assessing the radiation dose resulting from clinical dental CBCT.

  19. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  20. Study on the evaluation method of radiation dose rate around spent fuel shipping casks

    International Nuclear Information System (INIS)

    Yamakoshi, Hisao

    1986-01-01

    This study aims at developing a simple calculation method which can evaluate radiation dose rate around casks with high accuracy in a short time. The method is based on a concept of the radiation shielding characteristics of cask walls. The concept was introduced to replace for ordinary radiation shielding calculation which requires a long calculation time and a large memory capacity of a computer in the matrix calculation. For the purpose of verifying the accuracy and reliability of the new method, it was applied to the analysis of the dose rate distribution around actual casks, which had been measured. The results of the analysis revealed that the newly proposed method was excellent for the forecast of radiation dose rate distribution around casks in view of the accuracy and calculation time. The short calculation time and high accuracy by the proposed method were attained by dividing the whole procedure of ordinary fine radiation shielding calculation into the calculation of radiation dose rate on a cask surface by the matrix expression of the characteristic function and the calculation of dose rate distribution using the simple analytical expression of dose rate distribution around casks. The effect of the heterogeneous array of spent fuel in different burnup state on dose rate distribution around casks was evaluated by this method. (Kako, I.)

  1. Topics on study of low dose-effect relationship

    International Nuclear Information System (INIS)

    Yamada, Takeshi; Ohyama, Harumi

    1999-01-01

    It is not exceptional but usually observed that a dose-effect relationship in biosystem is not linear. Sometimes, the low dose-effect relationship appears entirely contrary to the expectation from high dose-effect. This is called a 'hormesis' phenomena. A high dose irradiation inflicts certainly an injury on biosystem. No matter how low the dose may be, an irradiation might inflict some injury on biosystem according to Linear Non-Threshold hypothesis(LNT). On the contrary to the expectation, a low dose irradiation stimulates immune system, and promotes cell proliferation. This is called 'radiation hormesis'. The studies of the radiation hormesis are made on from four points of view as follows: (1) radiation adaptive response, (2) revitalization caused by a low dose stimulation, (3) a low dose response unexpected from the LNT hypothesis, (4) negation of the LNT hypothesis. The various empirical proofs of radiation hormesis are introduced in the report. (M . Suetake)

  2. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  3. Low-dose effects of hormones and endocrine disruptors.

    Science.gov (United States)

    Vandenberg, Laura N

    2014-01-01

    Endogenous hormones have effects on tissue morphology, cell physiology, and behaviors at low doses. In fact, hormones are known to circulate in the part-per-trillion and part-per-billion concentrations, making them highly effective and potent signaling molecules. Many endocrine-disrupting chemicals (EDCs) mimic hormones, yet there is strong debate over whether these chemicals can also have effects at low doses. In the 1990s, scientists proposed the "low-dose hypothesis," which postulated that EDCs affect humans and animals at environmentally relevant doses. This chapter focuses on data that support and refute the low-dose hypothesis. A case study examining the highly controversial example of bisphenol A and its low-dose effects on the prostate is examined through the lens of endocrinology. Finally, the chapter concludes with a discussion of factors that can influence the ability of a study to detect and interpret low-dose effects appropriately. © 2014 Elsevier Inc. All rights reserved.

  4. Evaluation of the absorbed doses in conditions of external and internal contamination with radionuclides

    International Nuclear Information System (INIS)

    Milivojevic, K.; Stojanovic, D.; Markovic, P.

    1981-01-01

    In experimental conditions of contamination with radionuclides of the skin and skin injuries, an evaluation of the degree of local irradiation in decontamined region and doses absorbed in organs of selective accumulating was carried out by use of mathematical models and tissue-equivalent thermoluminescent dosemeters. The evaluation of the absorbed doses based on conception, that in adequate analyses of decontamination effect, as a most efficient medico-prophilactic measure from local and total irradiation, should be taken into account the total body burden of the penetrated radionuclide, selective accumulating in critical organs or tissues, as well as the residual radioactivity in decontaminated region. (author)

  5. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    International Nuclear Information System (INIS)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won

    2011-01-01

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  6. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won [Dept. of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-09-15

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  7. Biological effects of low doses of radiation at low dose rate

    International Nuclear Information System (INIS)

    1996-05-01

    The purpose of this report was to examine available scientific data and models relevant to the hypothesis that induction of genetic changes and cancers by low doses of ionizing radiation at low dose rate is a stochastic process with no threshold or apparent threshold. Assessment of the effects of higher doses of radiation is based on a wealth of data from both humans and other organisms. 234 refs., 26 figs., 14 tabs

  8. Radiation dose evaluation in patients submitted to conventional radiological examinations

    International Nuclear Information System (INIS)

    Tilly Junior, Joao G.

    1997-01-01

    This work presents the results of the evaluation of radiation dose delivered to the patients undergoing conventional radiological procedures. Based in the realized measurement some indicators are settled to quantitative appraisal of the radiological protection conditions offered to the population. Data assessment was done in the county of Curitiba, in Parana State, Brazil, from 12/95 to 04/96, in ten rooms of three different institutions, under 101 patients, adults with 70 ± 10 kg, during real examinations of chest PA, chest LAT and abdomen AP. (author)

  9. Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Rodríguez, Jesús, E-mail: jesus.silva.rodriguez@sergas.es; Aguiar, Pablo, E-mail: pablo.aguiar.fernandez@sergas.es [Fundación Ramón Domínguez, Santiago de Compostela, Galicia (Spain); Servicio de Medicina Nuclear, Complexo Hospitalario Universidade de Santiago de Compostela (USC), 15782, Galicia (Spain); Grupo de Imaxe Molecular, Instituto de Investigación Sanitarias (IDIS), Santiago de Compostela, 15706, Galicia (Spain); Sánchez, Manuel; Mosquera, Javier; Luna-Vega, Víctor [Servicio de Radiofísica y Protección Radiológica, Complexo Hospitalario Universidade de Santiago de Compostela (USC), 15782, Galicia (Spain); Cortés, Julia; Garrido, Miguel [Servicio de Medicina Nuclear, Complexo Hospitalario Universitario de Santiago de Compostela, 15706, Galicia, Spain and Grupo de Imaxe Molecular, Instituto de Investigación Sanitarias (IDIS), Santiago de Compostela, 15706, Galicia (Spain); Pombar, Miguel [Servicio de Radiofísica y Protección Radiológica, Complexo Hospitalario Universitario de Santiago de Compostela, 15706, Galicia (Spain); Ruibal, Álvaro [Servicio de Medicina Nuclear, Complexo Hospitalario Universidade de Santiago de Compostela (USC), 15782, Galicia (Spain); Grupo de Imaxe Molecular, Instituto de Investigación Sanitarias (IDIS), Santiago de Compostela, 15706, Galicia (Spain); Fundación Tejerina, 28003, Madrid (Spain)

    2014-05-15

    Purpose: Current procedure guidelines for whole body [18F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. Methods: One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manual ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Results: Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. Conclusions: The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion.

  10. [Evaluation of methods to calculate dialysis dose in daily hemodialysis].

    Science.gov (United States)

    Maduell, F; Gutiérrez, E; Navarro, V; Torregrosa, E; Martínez, A; Rius, A

    2003-01-01

    Daily dialysis has shown excellent clinical results because a higher frequency of dialysis is more physiological. Different methods have been described to calculate dialysis dose which take into consideration change in frequency. The aim of this study was to calculate all dialysis dose possibilities and evaluate the better and practical options. Eight patients, 6 males and 2 females, on standard 4 to 5 hours thrice weekly on-line hemodiafiltration (S-OL-HDF) were switched to daily on-line hemodiafiltration (D-OL-HDF) 2 to 2.5 hours six times per week. Dialysis parameters were identical during both periods and only frequency and dialysis time of each session were changed. Time average concentration (TAC), time average deviation (TAD), normalized protein catabolic rate (nPCR), Kt/V, equilibrated Kt/V (eKt/V), equivalent renal urea clearance (EKR), standard Kt/V (stdKt/V), urea reduction ratio (URR), hemodialysis product and time off dialysis were measured. Daily on-line hemodiafiltration was well accepted and tolerated. Patients maintained the same TAC although TAD decreased from 9.7 +/- 2 in baseline to a 6.2 +/- 2 mg/dl after six months, p time off dialysis was reduced to half. Dialysis frequency is an important urea kinetic parameter which there are to take in consideration. It's necessary to use EKR, stdKt/V or weekly URR to calculate dialysis dose for an adequate comparison between different frequency dialysis schedules.

  11. Extracranial stereotactic radiotherapy: Evaluation of PTV coverage and dose conformity

    International Nuclear Information System (INIS)

    Haedinger, U.; Thiele, W.; Wulf, J.

    2002-01-01

    During the past few years the concept of cranial sterotactic radiotherapy has been successfully extended to extracranial tumoral targets. In our department, hypofractionated treatment of tumours in lung, liver, abdomen, and pelvis is performed in the Stereotactic Body Frame (ELEKTA Instrument AB) since 1997. We present the evaluation of 63 consecutively treated targets (22 lung, 21 liver, 20 abdomen/pelvis) in 58 patients with respect to dose coverage of the planning target volume (PTV) as well as conformity of the dose distribution. The mean PTV coverage was found to be 96.3%±2.3% (lung), 95.0%±4.5% (liver), and 92.1%±5.2% (abdomen/pelvis). For the so-called conformation number we obtained values of 0.73±0.09 (lung), 0.77±0.10 (liver), and 0.70±0.08 (abdomen/pelvis). The results show that highly conformal treatment techniques can be applied also in extracranial stereotactic radiotherapy. This is primarily due to the relatively simple geometrical shape of most of the targets. Especially lung and liver targets turned out to be approximately spherically/cylindrically shaped, so that the dose distribution can be easily tailored by rotational fields. (orig.) [de

  12. Estimation of effective dose to public from external exposure to natural background radiation in saudi arabia

    International Nuclear Information System (INIS)

    Khalid, A. A.

    2003-01-01

    The effective dose values in sixteen cities in Saudi Arabia due to external exposure to natural radiation were evaluated. These doses are based on natural background components including external exposure to terrestrial radiation and cosmic rays. The importance of evaluating the effective dose to the public due to external exposure to natural background radiation lies in its epidemiological and dosimetric importance and in forming a basis for the assessment of the level of radioactive contamination or pollution in the environment in the future. The exposure to terrestrial radiation was measured using thermoluminescent dosimeters (TLD). The exposure from cosmic radiation was determined using empirical correlation. The values evaluated for the total annual effective dose in all cities were within the world average values. The highest total annual effective dose measured in Al-Khamis city was 802 μSv/y, as compared to 305 μSv/y in Dammam city, which was considered the lowest value

  13. The relative biological effectiveness of out-of-field dose

    International Nuclear Information System (INIS)

    Balderson, Michael; Koger, Brandon; Kirkby, Charles

    2016-01-01

    Purpose: using simulations and models derived from existing literature, this work investigates relative biological effectiveness (RBE) for out-of-field radiation and attempts to quantify the relative magnitudes of different contributing phenomena (spectral, bystander, and low dose hypersensitivity effects). Specific attention is paid to external beam radiotherapy treatments for prostate cancer. Materials and methods: using different biological models that account for spectral, bystander, and low dose hypersensitivity effects, the RBE was calculated for different points moving radially out from isocentre for a typical single arc VMAT prostate case. The RBE was found by taking the ratio of the equivalent dose with the physical dose. Equivalent doses were calculated by determining what physical dose would be necessary to produce the same overall biological effect as that predicted using the different biological models. Results: spectral effects changed the RBE out-of-field less than 2%, whereas response models incorporating low dose hypersensitivity and bystander effects resulted in a much more profound change of the RBE for out-of-field doses. The bystander effect had the largest RBE for points located just outside the edge of the primary radiation beam in the cranial caudal (z-direction) compared to low dose hypersensitivity and spectral effects. In the coplanar direction, bystander effect played the largest role in enhancing the RBE for points up to 8.75 cm from isocentre. Conclusions: spectral, bystander, and low dose hypersensitivity effects can all increase the RBE for out-of-field radiation doses. In most cases, bystander effects seem to play the largest role followed by low dose hypersensitivity. Spectral effects were unlikely to be of any clinical significance. Bystander, low dose hypersensitivity, and spectral effect increased the RBE much more in the cranial caudal direction (z-direction) compared with the coplanar directions. (paper)

  14. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    International Nuclear Information System (INIS)

    Lopez-Rendon, X.; Bosmans, H.; Zanca, F.; Oyen, R.

    2015-01-01

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  15. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, X. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); Bosmans, H.; Zanca, F. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium)

    2015-07-15

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  16. Dose enhancement effects of X ray radiation in bipolar transistors

    International Nuclear Information System (INIS)

    Chen Panxun

    1997-01-01

    The author has presented behaviour degradation and dose enhancement effects of bipolar transistors in X ray irradiation environment. The relative dose enhancement factors of X ray radiation were measured in bipolar transistors by the experiment methods. The mechanism of bipolar device dose enhancement was investigated

  17. Determination of effective dose of antimalarial from Cassia ...

    African Journals Online (AJOL)

    However, further investigation is required to determine an effective dose of the administered extract for a higher inhibitory effect and increasing effectiveness of the extract. Material and Methods: To determine the effective dose of ethanol extract of C. spectabilis leaves, a "4-day suppressive test"of Peter was performed with ...

  18. Effective dose equivalents from external radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Erkin, V.G.; Debedev, O.V.; Balonov, M.I.; Parkhomenko, V.I.

    1992-01-01

    Summarized data on measurements of individual dose of external γ-sources in 1987-1990 of population of western areas of Bryansk region were presented. Type of distribution of effective dose equivalent, its significance for various professional and social groups of population depending on the type of the house was discussed. Dependences connecting surface soil activity in the populated locality with average dose of external radiation sources were presented. Tendency of dose variation in 1987-1990 was shown

  19. Air contamination measurements for the evaluation of internal dose to workers in nuclear medicine departments

    Science.gov (United States)

    De Massimi, B.; Bianchini, D.; Sarnelli, A.; D'Errico, V.; Marcocci, F.; Mezzenga, E.; Mostacci, D.

    2017-11-01

    Radionuclides handled in nuclear medicine departments are often characterized by high volatility and short half-life. It is generally difficult to monitor directly the intake of these short-lived radionuclides in hospital staff: this makes measuring air contamination of utmost interest. The aim of the present work is to provide a method for the evaluation of internal doses to workers in nuclear medicine, by means of an air activity sampling detector, to ensure that the limits prescribed by the relevant legislation are respected. A continuous air sampling system measures isotope concentration with a Nal(TI) detector. Energy efficiency of the system was assessed with GEANT4 and with known activities of 18F. Air is sampled in a number of areas of the nuclear medicine department of the IRST-IRCCS hospital (Meldola- Italy). To evaluate committed doses to hospital staff involved (doctors, technicians, nurses) different exposure situations (rooms, times, radionuclides etc) were considered. After estimating the intake, the committed effective dose has been evaluated, for the different radionuclides, using the dose coefficients mandated by the Italian legislation. Error propagation for the estimated intake and personal dose has been evaluated, starting from measurement statistics.

  20. A PC program for estimating organ dose and effective dose values in computed tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Schmidt, B.; Schmidt, M.; Zankl, M.

    1999-01-01

    Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned. (orig.)

  1. Dose dependence on stochastic radiobiological effect in radiation risk estimation

    International Nuclear Information System (INIS)

    Komochkov, M.M.

    1999-01-01

    The analysis of the results in dose -- effect relationship observation has been carried out on the cell and organism levels, with the aim to obtain more precise data on the risk coefficients at low doses. The results are represented by two contrasting groups of dose dependence on effect: a downwards concave and a J-shaped curve. Both types of dependence are described by the equation solutions of an assumed unified protective mechanism, which comprises two components: constitutive and adaptive or inducible ones. The latest data analysis of the downwards concave dependence curves shows a considerable underestimation of radiation risk in all types of cancer, except leukemia, for a number of critical groups in a population, at low doses comparing to the ICRP recommendations. With the dose increase, the decrease of the effect value per dose unit is observed. It may be possibly related to the switching of the activity of the adaptive protective mechanism, with some threshold dose values being exceeded

  2. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuyoshi, Takamasa; Nakamura, Mitsuhiro, E-mail: m_nkmr@kuhp.kyoto-u.ac.jp; Matsuo, Yukinori; Ueki, Nami; Nakamura, Akira; Iizuka, Yusuke; Mampuya, Wambaka Ange; Mizowaki, Takashi; Hiraoka, Masahiro

    2016-01-01

    The purpose of this article is to quantitatively evaluate differences in dose distributions calculated using various computed tomography (CT) datasets, dose-calculation algorithms, and prescription methods in stereotactic body radiotherapy (SBRT) for patients with early-stage lung cancer. Data on 29 patients with early-stage lung cancer treated with SBRT were retrospectively analyzed. Averaged CT (Ave-CT) and expiratory CT (Ex-CT) images were reconstructed for each patient using 4-dimensional CT data. Dose distributions were initially calculated using the Ave-CT images and recalculated (in the same monitor units [MUs]) by employing Ex-CT images with the same beam arrangements. The dose-volume parameters, including D{sub 95}, D{sub 90}, D{sub 50}, and D{sub 2} of the planning target volume (PTV), were compared between the 2 image sets. To explore the influence of dose-calculation algorithms and prescription methods on the differences in dose distributions evident between Ave-CT and Ex-CT images, we calculated dose distributions using the following 3 different algorithms: x-ray Voxel Monte Carlo (XVMC), Acuros XB (AXB), and the anisotropic analytical algorithm (AAA). We also used 2 different dose-prescription methods; the isocenter prescription and the PTV periphery prescription methods. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data were within 3 percentage points (%pts) employing the isocenter prescription method, and within 1.5%pts using the PTV periphery prescription method, irrespective of which of the 3 algorithms (XVMC, AXB, and AAA) was employed. The frequencies of dose-volume parameters differing by >1%pt when the XVMC and AXB were used were greater than those associated with the use of the AAA, regardless of the dose-prescription method employed. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data on patients who underwent lung SBRT were within 3%pts, regardless of the dose

  3. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods

    International Nuclear Information System (INIS)

    Mitsuyoshi, Takamasa; Nakamura, Mitsuhiro; Matsuo, Yukinori; Ueki, Nami; Nakamura, Akira; Iizuka, Yusuke; Mampuya, Wambaka Ange; Mizowaki, Takashi; Hiraoka, Masahiro

    2016-01-01

    The purpose of this article is to quantitatively evaluate differences in dose distributions calculated using various computed tomography (CT) datasets, dose-calculation algorithms, and prescription methods in stereotactic body radiotherapy (SBRT) for patients with early-stage lung cancer. Data on 29 patients with early-stage lung cancer treated with SBRT were retrospectively analyzed. Averaged CT (Ave-CT) and expiratory CT (Ex-CT) images were reconstructed for each patient using 4-dimensional CT data. Dose distributions were initially calculated using the Ave-CT images and recalculated (in the same monitor units [MUs]) by employing Ex-CT images with the same beam arrangements. The dose-volume parameters, including D 95 , D 90 , D 50 , and D 2 of the planning target volume (PTV), were compared between the 2 image sets. To explore the influence of dose-calculation algorithms and prescription methods on the differences in dose distributions evident between Ave-CT and Ex-CT images, we calculated dose distributions using the following 3 different algorithms: x-ray Voxel Monte Carlo (XVMC), Acuros XB (AXB), and the anisotropic analytical algorithm (AAA). We also used 2 different dose-prescription methods; the isocenter prescription and the PTV periphery prescription methods. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data were within 3 percentage points (%pts) employing the isocenter prescription method, and within 1.5%pts using the PTV periphery prescription method, irrespective of which of the 3 algorithms (XVMC, AXB, and AAA) was employed. The frequencies of dose-volume parameters differing by >1%pt when the XVMC and AXB were used were greater than those associated with the use of the AAA, regardless of the dose-prescription method employed. All differences in PTV dose-volume parameters calculated using Ave-CT and Ex-CT data on patients who underwent lung SBRT were within 3%pts, regardless of the dose-calculation algorithm or the

  4. Individually dosed omalizumab: an effective treatment for severe peanut allergy.

    Science.gov (United States)

    Brandström, J; Vetander, M; Lilja, G; Johansson, S G O; Sundqvist, A-C; Kalm, F; Nilsson, C; Nopp, A

    2017-04-01

    Treatment with omalizumab has shown a positive effect on food allergies, but no dosages are established. Basophil allergen threshold sensitivity (CD-sens) can be used to objectively measure omalizumab treatment efficacy and correlates with the outcome of double-blind placebo-controlled food challenge to peanut. To evaluate whether individualized omalizumab treatment monitored by CD-sens could be an effective intervention for suppression of allergic reactions to peanut. Severely peanut allergic adolescents (n = 23) were treated with omalizumab for 8 weeks, and CD-sens was analysed before and after. Based on whether CD-sens was suppressed after 8 weeks, the patients either were subject to a peanut challenge or received eight more weeks with increased dose of omalizumab, followed by peanut challenge or another 8-week cycle of omalizumab. IgE and IgE-antibodies to peanut and its components were analysed before treatment. After individualized omalizumab treatment (8-24 weeks), all patients continued with an open peanut challenge with no (n = 18) or mild (n = 5) objective allergic symptoms. Patients (n = 15) needing an elevated omalizumab dose (ED) to suppress CD-sens had significantly higher CD-sens values at baseline 1.49 (0.44-20.5) compared to those (n = 8) who managed with normal dose (ND) 0.32 (0.24-5.5) (P omalizumab, monitored by CD-sens, is an effective and safe treatment for severe peanut allergy. The ratio of IgE-ab to storage protein Ara h 2/IgE as well as CD-sens to peanut may predict the need of a higher omalizumab dose. Clinical trials numbers: EudraCT; 2012-005625-78, ClinicalTrials.gov; NCT02402231. © 2016 John Wiley & Sons Ltd.

  5. Evaluation of patient radiation doses using DAP meter in interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Sam [Dept. of Radiological Technology. Shingu University, Sungnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu Univeristy, Kyushu (Japan)

    2017-03-15

    The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipment in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effective of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were 237.7 Gy·cm{sup 2} in TACE, 17.3 Gy·cm{sup 2} in AVF, 114.1 Gy·cm{sup 2} in LE PTA and STENT, 188.5 Gy·cm{sup 2} in TFCA, 383.5 Gy·cm{sup 2} in Aneurysm Coil, 64.6 Gy·cm{sup 2} in PTBD, 64.6 Gy·cm{sup 2} in Biliary Stent, 22.4 Gy·cm{sup 2} in PCN, 4.3 Gy·cm{sup 2} in Hickman, 2.8 Gy·cm{sup 2} in Chemo-port, 4.4 Gy·cm{sup 2} in Perm-Cather, 17.1 Gy·cm{sup 2} in PCD, and 357.9 Gy·cm{sup 2} in Vis, EMB. Dose reference level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipment and procedures in the interventional radiology procedures, further studies and monitoring are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

  6. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  7. Evaluation of patient absorbed dose in a PET-CT test

    International Nuclear Information System (INIS)

    Guerra P, F.; Mourao F, A. P.; Santana, P. C.

    2017-10-01

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg 18 F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the 18 F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  8. A study of different dose calculation methods and the impact on the dose evaluation protocol in lung stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Takada, Takahiro; Furuya, Tomohisa; Ozawa, Shuichi; Ito, Kana; Kurokawa, Chie; Karasawa, Kumiko; Miura, Kohei

    2008-01-01

    AAA (analytical anisotropic algorithm) dose calculation, which shows a better performance for heterogeneity correction, was tested for lung stereotactic radiation therapy (SBRT) in comparison to conventional PBC (pencil beam convolution method) to evaluate its impact on tumor dose parameters. Eleven lung SBRT patients who were treated with photon 4 MV beams in our department between April 2003 and February 2007 were reviewed. Clinical target volume (CTV) was delineated including the spicula region on planning CT images. Planning target volume (PTV) was defined by adding the internal target volume (ITV) and set-up margin (SM) of 5 mm from CTV, and then an multileaf collimator (MLC) penumbra margin of another 5 mm was also added. Six-port non-coplanar beams were employed, and a total prescribed dose of 48 Gy was defined at the isocenter point with four fractions. The entire treatment for an individual patient was completed within 8 days. Under the same prescribed dose, calculated dose distribution, dose volume histogram (DVH), and tumor dose parameters were compared between two dose calculation methods. In addition, the fractionated prescription dose was repeatedly scaled until the monitor units (MUs) calculated by AAA reached a level of MUs nearly identical to those achieved by PBC. AAA resulted in significantly less D95 (irradiation dose that included 95% volume of PTV) and minimal dose in PTV compared to PBC. After rescaling of each MU for each beam in the AAA plan, there was no revision of the isocenter of the prescribed dose required. However, when the PTV volume was less than 20 cc, a 4% lower prescription resulted in nearly identical MUs between AAA and PBC. The prescribed dose in AAA should be the same as that in PBC, if the dose is administered at the isocenter point. However, planners should compare DVHs and dose distributions between AAA and PBC for a small lung tumor with a PTV volume less than approximately 20 cc. (author)

  9. Evaluation of doses in conventional radiology in the cities of Rio de Janeiro e Recife, Brazil

    International Nuclear Information System (INIS)

    Azevedo, Ana Cecilia P.; Osibote, Adelaja O.; Khoury, Helen J.

    2005-01-01

    This work is part of a program of evaluating doses in patients developed in several hospitals in the States of Rio de Janeiro and Pernambuco. We used the program DoseCal to evaluate the Input Skin Dose (DEP) and the Effective Dose (DE) in big public hospitals in the cities of Rio de Janeiro and Recife. It were included in the survey the doses of chest radiographs, cervical spine, lumbar spine, skull and pelvis in the projections AP, PA and LAT. To chest in PA the average value of DEP for the hospital A was 0.19 mGy. For to hospital B was 0.07 mGy. For the exam of the skull in PA the average value in A was 3.25 mGy and B of 0.49 mGy. With respect to radiological techniques might be noted that in most cases the hospital A used kilovoltage lower than in B and miliamperes higher. This can be one of the explanations for the difference of the values found for DEP and DE. The results showed significant discrepancies in values of doses as radiographic techniques when compared to the requirements established by the European Community for X-rays with image quality. This result is due to several factors: filtration, radiographic technique, professional technical experience and performance of radiographic equipment

  10. Biochemical and cellular mechanisms of low-dose effects

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Booz, J.; Muehlensiepen, H.

    1988-01-01

    The question of health effects from small radiation doses remains open. Individual cells, when being hit by single elemental doses - in low-dose irradiation - react acutely and temporarily by altering control of enzyme activity, as is demonstrated for the case of thymidine kinase. This response is not constant in that it provides a temporary protection of enzyme activity against a second irradiation, by a mechanism likely to be via improved detoxification of intracellular radicals. It must be considered that in the low-dose region radiation may also exert protection against other challenges involving radicals, causing a net beneficial effect by temporarily shielding the hit cell against radicals produced by metabolism. Since molecular alterations leading to late effects are considered a consequence of the initial cellular response, late effects from small radiation doses do not necessarily adhere to a linear dose-effect relationship. The reality of the linear relationship between the risk of late effects from high doses to small doses is an assumption, for setting dose limits, but it must not be taken for predicting health detriment from low doses. (author)

  11. Effective doses to family members of patients treated with radioiodine-131

    International Nuclear Information System (INIS)

    Kocovska, M Zdraveska; Vaskova, O; Majstorov, V; Kuzmanovska, S; Gjorceva, D Pop; Jokic, V Spasic

    2011-01-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine-131, and also to compare the results with dose constraints proposed by the International Commission of Radiological Protection (ICRP) and the Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). For the estimation of the effective doses, sixty family members of sixty patients, treated with radioiodine-131, and thermoluminiscent dosimeters (Model TLD 100) were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore TLD in front of the torso for seven days. The radiation doses to family members of thyroid cancer patients were well below the recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected for 11 family members of hyperthyroid patients. The mean value of effective dose of family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79). The estimated effective doses to family members of hyperthyroid patients were higher than the effective doses to family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.

  12. Evaluation of radiation dose to pediatric patients during certain special procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Elhag, B.; Babikir, E.; Alsafi, K.

    2014-01-01

    This study was intended to measure pediatric entrance surface air kerma (ESAK) and effective dose during micturating cystourethrography (MCU), intravenous urography (IVU) and barium studies (barium meal, enema, and swallow) and to propose a local diagnostic reference level (DRL). ESAK was measured for patients using calibrated thermoluminescent dosimeters (TLDs, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 236 special pediatric procedures were investigated. 21.7% of the sample comprised barium procedures, 18.6% were MCU procedures while 59.5% of the sample were IVU procedures. The mean ESAK measurements (mGy) were 2.1±0.8, 3.0±23 and 1.2±0.2 for barium meal, enema and swallow in the same order. The mean patient dose for IVU procedures was 12.4±8.7 mGy per procedure and the mean patient dose per MCU procedure was 5.8±7 mGy. Local DRLs were proposed for all procedures. The patient doses in this study are within the reported values, suggesting that pediatric patients are adequately protected. - Highlights: • Pediatric radiation dose has been evaluated for three of the most common fluoroscopic procedures. • Radiation doses were measured using calibrated TLD GR200A. • Pediatric patients of concern and ESAK doses showed large variations. • The patient doses in this study are within the reported studies suggesting that the pediatric patients are adequately protected

  13. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R.; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  14. Evaluation of the absorbed dose in odontological computerized tomography; Avaliacao da dose absorvida em tomografia computadorizada odontologica

    Energy Technology Data Exchange (ETDEWEB)

    Legnani, Adriano; Schelin, Hugo R; Rocha, Anna Silvia P.S. da, E-mail: schelin@utfpr.edu.b, E-mail: anna@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Khoury, Helen J., E-mail: khoury@ufpe.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil)

    2011-10-26

    This paper evaluated the absorbed dose at the surface entry known as 'cone beam computed tomography' (CBCT) in odontological computerized tomography. Examination were simulated with CBCT for measurements of dose. A phantom were filled with water, becoming scatter object of radiation. Thermoluminescent dosemeters were positioned on points correspondent to eyes and salivary glands

  15. Field evaluations of the VDmax approach for substantiation of a 25 kGy sterilization dose and its application to other preselected doses

    International Nuclear Information System (INIS)

    Kowalski, John B.; Herring, Craig; Baryschpolec, Lisa; Reger, John; Patel, Jay; Feeney, Mary; Tallentire, Alan

    2002-01-01

    The International and European standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. An approach, designated VD max , has recently been described and computer evaluated to provide safe and unambiguous substantiation of a 25 kGy sterilization dose. The approach has been further developed into a practical method, which has been subjected to field evaluations at three manufacturing facilities which produce different types of medical devices. The three facilities each used a different overall evaluation strategy: Facility A used VD max for quarterly dose audits; Facility B compared VD max and Method 1 in side-by-side parallel experiments; and Facility C, a new facility at start-up, used VD max for initial substantiation of 25 kGy and subsequent quarterly dose audits. A common element at all three facilities was the use of 10 product units for irradiation in the verification dose experiment. The field evaluations of the VD max method were successful at all three facilities; they included many different types of medical devices/product families with a wide range of average bioburden and sample item portion values used in the verification dose experiments. Overall, around 500 verification dose experiments were performed and no failures were observed. In the side-by-side parallel experiments, the outcomes of the VD max experiments were consistent with the outcomes observed with Method 1. The VD max approach has been extended to sterilization doses >25 and max method for doses other than 25 kGy must await controlled field evaluations and the development of appropriate specifications/standards

  16. Computational assessment of effective dose and patient specific doses for kilovoltage stereotactic radiosurgery of wet age-related macular degeneration

    Science.gov (United States)

    Hanlon, Justin Mitchell

    Age-related macular degeneration (AMD) is a leading cause of vision loss and a major health problem for people over the age of 50 in industrialized nations. The current standard of care, ranibizumab, is used to help slow and in some cases stabilize the process of AMD, but requires frequent invasive injections into the eye. Interest continues for stereotactic radiosurgery (SRS), an option that provides a non-invasive treatment for the wet form of AMD, through the development of the IRay(TM) (Oraya Therapeutics, Inc., Newark, CA). The goal of this modality is to destroy choroidal neovascularization beneath the pigment epithelium via delivery of three 100 kVp photon beams entering through the sclera and overlapping on the macula delivering up to 24 Gy of therapeutic dose over a span of approximately 5 minutes. The divergent x-ray beams targeting the fovea are robotically positioned and the eye is gently immobilized by a suction-enabled contact lens. Device development requires assessment of patient effective dose, reference patient mean absorbed doses to radiosensitive tissues, and patient specific doses to the lens and optic nerve. A series of head phantoms, including both reference and patient specific, was derived from CT data and employed in conjunction with the MCNPX 2.5.0 radiation transport code to simulate treatment and evaluate absorbed doses to potential tissues-at-risk. The reference phantoms were used to evaluate effective dose and mean absorbed doses to several radiosensitive tissues. The optic nerve was modeled with changeable positions based on individual patient variability seen in a review of head CT scans gathered. Patient specific phantoms were used to determine the effect of varying anatomy and gaze. The results showed that absorbed doses to the non-targeted tissues were below the threshold levels for serious complications; specifically the development of radiogenic cataracts and radiation induced optic neuropathy (RON). The effective dose

  17. Evaluation of the dose committed as based on direct measurements with the Whole Body Counter

    International Nuclear Information System (INIS)

    Meladani, C.; Castellani, C.M.; Battisti, P.; Tarroni, G.

    1989-01-01

    During normal working activities or in accidental situations, when the introduction of radioactive gamma emitters is non-negligible amount, accurate determination of effective committed dose equivalent based on direct measurements of the internal contamination cannot be avoided. Internal contamination measurements carried out by Whole Body Counter and the application of dosimetric and metabolic models as proposed by ICRP Publication 30 allow the intakes and committed dose equivalents to be evaluated. This paper presents the evaluation methodologies of committed dose equivalent both for istantaneous and extended contaminations. Furthermore, some advice about useful, opportune modes and time uncertainties due to the application of generalized models to particular situations, are also reported. On the basis of the Chernobyl experience, the general criteria for the chice and size of homogeneous groups of individuals to be measured, are finally submitted with a view to collecting the necessary radiation protection information concerning contamination of a part or a whole population

  18. A consideration on internal dose evaluation and intervention based on a surface contamination concept

    International Nuclear Information System (INIS)

    Yasuda, H.

    1997-01-01

    Long-term radiation doses received by the inhabitants after the Chernobyl accident have been evaluated according to the surface contamination levels on the ground surface. The health effects have also been discussed by comparison between the surface-contaminated area and the uncontaminated control area. Selected protective measures were carried out in accordance with the contamination level of surface soil. These have been based on the 'surface contamination concept' which assumes that the radiation risk to inhabitants is proportional to the level of ground-surface contamination. The observations collected in regions around Chernobyl, however, show that the internal radiation doses to the inhabitants poorly correlate with the surface contamination level. This fact poses a question on the suitability of dose evaluations and interventions based on this concept

  19. Effective dose and cancer risk in PET/CT exams

    International Nuclear Information System (INIS)

    Pinto, Gabriella M.; Sa, Lidia Vasconcellos de

    2013-01-01

    Due to the use of radiopharmaceutical positron-emitting in PET exam and realization of tomography by x-ray transmission in CT examination, an increase of dose with hybrid PET/CT technology is expected. However, differences of doses have been reported in many countries for the same type of procedure. It is expected that the dose is an influent parameter to standardize the protocols of PET/CT. This study aimed to estimate the effective doses and absorbed in 65 patients submitted to oncological Protocol in a nuclear medicine clinic in Rio de Janeiro, considering the risk of induction of cancer from the scan. The CT exam-related doses were estimated with a simulator of PMMA and simulated on the lmPACT resistance, which for program effective dose, were considered the weight factors of the lCRP 103. The PET exam doses were estimated by multiplying the activity administered to the patient with the ICRP dose 80 factors. The radiological risk for cancer incidence were estimated according to the ICRP 103. The results showed that the effective dose from CT exam is responsible for 70% of the effective total in a PET/CT scan. values of effective dose for the PET/CT exam reached average values of up to 25 mSv leading to a risk of 2, 57 x 10 -4 . Considering that in staging of oncological diseases at least four tests are performed annually, the total risk comes to 1,03x 10 -3

  20. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

    International Nuclear Information System (INIS)

    Rampado, Osvaldo; Giglioli, Francesca Romana; Rossetti, Veronica; Ropolo, Roberto; Fiandra, Christian; Ragona, Riccardo

    2016-01-01

    Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K_a_i_r), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses

  1. Equivalent dose, effective dose and risk assessment from cephalometric radiography to critical organs

    International Nuclear Information System (INIS)

    Kang, Seong Sook; Cho, Bon Hae; Kim, Hyun Ja

    1995-01-01

    In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites (18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The following results were obtained; 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (3.6 μSv) and the next highest dose was that received by the bone marrow (3 μSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland (2 μSv) and the next highest dose was that received by the bone marrow (1.8 μSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland (31.4 μSv) and the next highest dose was that received by the salivary gland (13.3 μSv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were 0.72 X 10 -6 , 0.49 X 10 -6 and 3.51 X 10 -6 , respectively.

  2. Effect of low dose radiation on apoptosis in mouse spleen

    International Nuclear Information System (INIS)

    Chen Dong; Liu Jiamei; Chen Aijun; Liu Shuzheng

    1999-01-01

    Objective: To study the effect of whole body irradiation (WBI) with different doses of X-ray on apoptosis in mouse spleen. Methods: Time course changes and dose-effect relationship of apoptosis in mouse spleen induced by WBI were observed with transmission electron microscopy (TEM) qualitatively and TUNEL method semi-quantitatively. Results: Many typical apoptotic lymphocytes were found by TEM in mouse spleen after WBI with 2 Gy. No marked alterations of ultrastructure were found following WBI with 0.075 Gy. It was observed by TUNEL that the apoptosis of splenocytes increased after high dose radiation and decreased following low dose radiation (LDR). The dose-effect relationship of radiation-induced apoptosis showed a J-shaped curve. Conclusion: The effect of different doses of ionizing radiation on apoptosis in mouse spleen was distinct. And the decrease of apoptosis after LDR is considered a manifestation of radiation hormesis

  3. A new study on the effects of low doses

    International Nuclear Information System (INIS)

    Dousset, M.; Jammet, H.

    1986-01-01

    A study conducted by prof. Rose has investigated mortality among 39540 employees of the UKAEA, from 1946 to 1978. The three main points are: 1. General mortality and mortality from malignant diseases are lower than in the population of England and Wales (74 and 79 per cent respectively), thus showing no major difference between workers monitored for exposure to radiation and other workers. 2. For monitored workers, the only death cause for which there is a statistically significant correlation with radiation exposure is prostate cancer; there are many cases especially in workers with doses exceeding 0.05 Sv (5 rem) and monitored for tritium. Such a correlation has never been found in any other epidemiologic survey of workers exposed to low-level doses, Hanford (USA) workers especially; conversely, mortality from either multiple myeloma or pancreas cancer is not found here. These facts plead for a cautious interpretation of the results as a whole. 3. A linear representation of the variations of leukemia and cancer mortality vs exposure results in lines, the slopes of which are 3 times higher than those of the lines adopted by ICRP; however, the 95% confidence intervals (-2.7 + 12.4 and -22 + 52.5) are such that the results are compatible with a null effect (slope 0) and even with a benefic effect (negative slope). They are therefore compatible with ICRP estimations. A recent attempt to evaluate the two main investigations on low-dose occupational exposures (UKAEA and Hanford) suggests a dose-response relationship very near that of ICRP [fr

  4. Dose and dose rate effects on coherent-to-incoherent transition of precipitates upon irradiation

    Institute of Scientific and Technical Information of China (English)

    LI Zhengchao

    2006-01-01

    A typical precipitation hardened alloy, Cu-Co dilute alloy was selected to study the precipitation behavior and irradiation effect on precipitates. It is found that the principal effect of ion irradiation on the coherent precipitates is loss of coherency, and TEM cross-section observations show that the fraction of the incoherent precipitates is dependent on dose but not on dose rate during heavy ion irradiation.

  5. Evaluation of the enter surface dose, dose in organ and E effective dose, received by personnel and patients in studies of endoscopic retrograde cholangeopancreatography in the General Hospital of Mexico; Evaluacion de la dosis de entrada superficie, dosis en organo y dosis efectiva E, recibidas por personal y pacientes en estudios de colangiopancreatografia retrograda endoscopica en el Hospital General de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, S; Gama T, G [Calidad XXI SA de CV, Zacatecas 67-007 Col. Roma, 06700 Mexico D.F. (Mexico); Beristain, M; Espino, H [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Mexico D.F. (Mexico)

    2006-07-01

    The ESD for patient and personal is measured: gastroenterologuist endoscopist G1, A1 Assistant and A2 instrumentist that carried out 22 independent therapeutic procedures of CPRE, in a fluoroscopy equipment Toshiba trademark with tube under the table, operated in automatic exposure mode, CAE to average tensions of 80 kVp. The measurement is carried out with film dosemeters of double emulsion Kodak Type 2 trademark, calibrated in terms of H{sup *} for the energy of the {sup 137} Cs, first it is determined the films sensitivity like function of the optical density DO, and second the ESD for the effective energy of the radiation beam (50 keV), in three different points from the dosemeter (C, D and H). The films was placed for the personnel in: right hand, front (eye), thyroid and thorax (under D and out F of the lead apron); in the case of the patient three positions were used: thorax, hepatic region and pelvis. The mean values of the ESD and it standard deviation SD in mGy units are determined by: study, personnel, film position in doctor and patient, dosemeter measurement point. The calculated doses in organ are also determined for the patient in the thorax region, liverwort and pelvis its are agreement with the NRPB SR 262 report. Finally the H{sub E} and E for medical personnel and patients are estimated demonstrating that its are not exceeded the annual dose limits for the case of the OEP. In the case of the the OEP have for the D thorax an ESD{sub max} = 0.04 mGy that one corresponds an H{sub E} = 0.02 and E = 0.01 mSv. (Author)

  6. Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1)

    International Nuclear Information System (INIS)

    Sato, Osamu; Uehara, Takashi; Yoshizawa, Nobuaki; Iwai, Satoshi; Tanaka, Shun-ichi.

    1992-09-01

    Computer code system and basic data have been investigated for evaluating fluence to dose equivalent conversion factors for photons and neutrons up to 10 GeV. The present work suggested that the conversion factors would be obtained by incorporating effective quality factors of charged particles into the HERMES (High Energy Radiation Monte Carlo Elaborate System) code system. The effective quality factors for charged particles were calculated on the basis of the Q-L relationships specified in the ICRP Publication-60. (author)

  7. Computational fluid dynamics (CFD) assisted performance evaluation of the Twincer (TM) disposable high-dose dry powder inhaler

    NARCIS (Netherlands)

    de Boer, Anne H.; Hagedoorn, Paul; Woolhouse, Robert; Wynn, Ed

    Objectives To use computational fluid dynamics (CFD) for evaluating and understanding the performance of the high-dose disposable Twincer (TM) dry powder inhaler, as well as to learn the effect of design modifications on dose entrainment, powder dispersion and retention behaviour. Methods Comparison

  8. Experimental study on x-rays dose enhancement effects for floating gate ROMs

    CERN Document Server

    Guo Hong Xia; Chen Yu Sheng; Han Fu Bin; He Chao Hui; Zhao Hui

    2002-01-01

    Experimental results of x-ray dose enhancement effects are given for floating gate read-only memory (ROMs) irradiated in the Beijing Synchrotron Radiation Facility. The wrong byte numbers vs. total irradiation dose have been tested and the equivalent relation of total dose damage is provided compared the response of devices irradiated with sup 6 sup 0 Co gamma-ray source. The x-ray dose enhancement factors for floating gate ROMs are obtained firstly in China. These results can be an effective evaluation data for x-rays radiation hardening technology

  9. Dose dependent sun protective effect of topical melatonin

    DEFF Research Database (Denmark)

    Scheuer, Cecilie; Pommergaard, Hans-Christian; Rosenberg, Jacob

    2016-01-01

    BACKGROUND: Ultraviolet radiation (UVR) by sunlight results in an increasing number of skin conditions. Earlier studies have suggested a protective effect of topical treatment with the pineal hormone melatonin. However, this protective effect has never been evaluated in natural sunlight......-blind study in healthy volunteers. Twenty-three healthy volunteers, 8 male and 15 female, were enrolled. The protective effect of three different doses of melatonin cream (0.5%, 2.5%, 12.5%) against erythema induced by natural sunlight was tested. All participants had their backs exposed to sun from 1:22 PM.......5% concentrations. CONCLUSION: Application of melatonin cream 12.5% protects against natural sunlight induced erythema....

  10. uv keratoconjunctivitis vs. established dose effect relationships

    International Nuclear Information System (INIS)

    Gulvady, N.U.

    1976-01-01

    A patient who received a uv dose to his eyes 11 times greater than the photokeratitic threshold of Pitts and 4 1 / 2 times the photokeratitic threshold as found by Leach. The patient had severe keratoconjunctivitis for 3 days and did not develop any keratitis

  11. Page 1 ~'----------------------------- Dose-dependent effects ...

    African Journals Online (AJOL)

    Abstract We cOInpared the serwn levels of oestrogen and progesterone and the endoInetrial Inorphology of. nOrInal pregnant rats at 5,5 days' gestation ~th those of pregnant rats given either low (10 IU) or high (20 IU) doses of two gonadotrophins: follicle-. stiInulating hOrInone (FSH) and hwnan chorionic gonadotrophin ...

  12. Evaluation of radiological doses to the terrestrial plants around Trombay

    International Nuclear Information System (INIS)

    Ajay Kumar; Singhal, R.K.; Preetha, J.; Joshi, S.N.; Hegde, A.G.

    2005-01-01

    Existing policies for radiation protection do not provide explicit criteria for the protection of species other than humans, i.e. not for flora and fauna. Concern over this omission is now being widely expressed and moves are under way to evaluate the doses to terrestrial and aquatic biota. During the present work radiological doses (external and internal) to the terrestrial plants were evaluated by estimating the concentration of anthropogenic ( 137 Cs, 90 Sr) and natural radionuclides ( 238 U, 232 Th and 40 K) in the plant leaves and by measuring the external gamma radiation due to different radionuclide. The soil and vegetation sample were collected from fifteen sampling locations around the different locations at Trombay. The samples were processed as per IAEA (International Atomic Energy Agency) protocol for the estimation of naturally occurring and anthropogenic radionuclides in soil and terrestrial plants. The gamma emitting radionuclides were measured by high resolution gamma (HPGe) spectrometry system. Maximum exposure (external + internal) to the terrestrial plants was observed due to 232 Th while 238 U showed minimum exposure. The average value of radiation exposure to the terrestrial plants for 40 K, 137 Cs, 90 Sr, 238 U and 232 Th was 1555.2 ± 92.4, 691.2 ± 54.3, 2564.1 ± 534.9, 82.5 ±5.2, and 4419.6 ± 1165.5 μGy/y respectively. The radiation exposure (external + internal ) to the terrestrial plants due to all radionuclides was found within the permissible limits (i.e. 10 mGy/d) as per recommended by the United States, Department of Energy (DOE). (author)

  13. The evaluation of lens absorbed dose according to the optimold for whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yong Mo; Park, Byoung Suk; Ahn, Jong Ho; Song, Ki Won [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made up to 5 mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. When there was the Optimold mask in the eyeball part, it was measured at 10.2cGy ± 1.5 in the simulation therapy, and at 24.8cGy ± 2.7 in the treatment, and when the Optimold mask was removed in the eye part, it was measured at 12.9cGy ± 2.2 in the simulation therapy, and at 17.6cGy ± 1.5 in the treatment. In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3cGy in the simulation therapy and was reduced approximately 7cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause

  14. The evaluation of lens absorbed dose according to the optimold for whole brain radiation therapy

    International Nuclear Information System (INIS)

    Yang, Yong Mo; Park, Byoung Suk; Ahn, Jong Ho; Song, Ki Won

    2014-01-01

    In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made up to 5 mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. When there was the Optimold mask in the eyeball part, it was measured at 10.2cGy ± 1.5 in the simulation therapy, and at 24.8cGy ± 2.7 in the treatment, and when the Optimold mask was removed in the eye part, it was measured at 12.9cGy ± 2.2 in the simulation therapy, and at 17.6cGy ± 1.5 in the treatment. In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3cGy in the simulation therapy and was reduced approximately 7cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause

  15. Epidemiological methods for assessing dose-response and dose-effect relationships

    DEFF Research Database (Denmark)

    Kjellström, Tord; Grandjean, Philippe

    2007-01-01

    Selected Molecular Mechanisms of Metal Toxicity and Carcinogenicity General Considerations of Dose-Effect and Dose-Response Relationships Interactions in Metal Toxicology Epidemiological Methods for Assessing Dose-Response and Dose-Effect Relationships Essential Metals: Assessing Risks from Deficiency......Description Handbook of the Toxicology of Metals is the standard reference work for physicians, toxicologists and engineers in the field of environmental and occupational health. This new edition is a comprehensive review of the effects on biological systems from metallic elements...... access to a broad range of basic toxicological data and also gives a general introduction to the toxicology of metallic compounds. Audience Toxicologists, physicians, and engineers in the fields of environmental and occupational health as well as libraries in these disciplines. Will also be a useful...

  16. The radiosensitizing effect of doranidazole on human colorectal cancer cells exposed to high doses of irradiation

    International Nuclear Information System (INIS)

    Zhang, Li; Gong, Aimin; Ji, Jun; Wu, Yuanyuan; Zhu, Xiaoyu; Lv, Suqing; Lv, Hongzhu; Sun, Xizhuo

    2007-01-01

    This paper investigates the effects of a new radiosensitizer, doranidazole, and enhancing irradiation on colorectal cancer cells. The radiosensitizing effect of doranidazole was determined using colony formation and propidium iodide (PI) assays to measure cell growth inhibition and the cell killing effect of human colorectal cancer cell lines exposed to high doses of γ-ray irradiation under hypoxic conditions in vitro. Fluorescence staining and cell migration assays were also used to assess the radiosensitizing effect. Cell proliferation evaluated by clonogenic survival curves was significantly inhibited by 5 mmol/L doranidazole, particularly at doses ranging from 10 to 30 Gy of irradiation. The radiosensitizing effect of doranidazole on colorectal cancer cells occurs in a time- and dose-dependent manner. Doranidazole also inhibited the mobility of cell invasion and migration. Doranidazole can enhance the killing effect and the cell growth inhibition of colorectal cancer after high-dose irradiation in a time and dose-dependent manner

  17. Environmental radioactivity and dose evaluation in Taiwan after the Chernobyl accident

    International Nuclear Information System (INIS)

    Chung, C.E.

    1989-01-01

    A substantial increase in fission product activity was observed in various environmental samples taken in Taiwan after the Chernobyl accident. The concentration of long-lived fission products in air above ground, precipitation, grass, vegetation and milk were monitored in the next 7 wk. The individual effective dose equivalent committed by the first year of exposure and intake following the accident were evaluated. Average individual doses for the population in Taiwan are estimated at 0.9 microSv due to global fallout from the Chernobyl accident. This value is lower than that reported in neighboring countries in the Far East and poses no increased health impact to the public in Taiwan

  18. Evaluation of the low dose cardiac CT imaging using ASIR technique

    Science.gov (United States)

    Fan, Jiahua; Hsieh, Jiang; Deubig, Amy; Sainath, Paavana; Crandall, Peter

    2010-04-01

    Today Cardiac imaging is one of the key driving forces for the research and development activities of Computed Tomography (CT) imaging. It requires high spatial and temporal resolution and is often associated with high radiation dose. The newly introduced ASIR technique presents an efficient method that offers the dose reduction benefits while maintaining image quality and providing fast reconstruction speed. This paper discusses the study of image quality of the ASIR technique for Cardiac CT imaging. Phantoms as well as clinical data have been evaluated to demonstrate the effectiveness of ASIR technique for Cardiac CT applications.

  19. Image Quality, Overall Evaluability, and Effective Radiation Dose of Coronary Computed Tomography Angiography With Prospective Electrocardiographic Triggering Plus Intracycle Motion Correction Algorithm in Patients With a Heart Rate Over 65 Beats Per Minute.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Baggiano, Andrea; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-01-16

    Recently, a new intracycle motion correction algorithm (MCA) was introduced to reduce motion artifacts from heart rate (HR) in coronary computed tomography angiography (cCTA). The aim of the study was to evaluate the image quality, overall evaluability, and effective radiation dose (ED) of cCTA with prospective electrocardiographic (ECG) triggering plus MCA as compared with standard protocol with retrospective ECG triggering in patients with HR≥65 bpm. One hundred consecutive patients (67±10 y) scheduled for cCTA with 65Ethics Committee and a written informed consent was obtained from all patients. Image noise, signal to noise ratio, contrast to noise ratio, Likert image quality score (score 1, nondiagnostic; score 2, adequate; score 3, good; score 4, excellent), overall image evaluability, and ED were measured and compared between the 2 groups. Both vessel-based and patient-based analyses were evaluated. Student test or Wilcoxon test were used to evaluate differences of continuous variables, whereas the χ test was used to study differences with regard to categorical data. A P-value <0.05 was considered statistically significant. cCTA was successfully performed in all patients. In a segment-based model, group 1 compared with group 2 showed a lower rate of overall artifacts (67% vs. 83%; P<0.001) and motion artifacts (49% vs. 66%; P<0.001), resulting in a better Likert image quality score (2.83±1.03 vs. 2.37±1.02; P<0.01) and overall evaluability (85% vs. 75%; P<0.01). Group 1 showed a lower ED as compared with group 2 (3.1±1.9 vs. 11.9±3.3 mSv; P<0.01). MCA and cCTA with prospective ECG-triggering acquisition in patients with high HR improves image quality and overall evaluability compared with cCTA with standard retrospective ECG triggering.

  20. Benefits of the effective dose equivalent concept at a medical center

    International Nuclear Information System (INIS)

    Vetter, R.J.; Classic, K.L.

    1991-01-01

    A primary objective of the recommendations of the International Committee on Radiological Protection Publication 26 is to insure that no source of radiation exposure is unjustified in relation to its benefits. This objective is consistent with goals of the Radiation Safety Committee and Institutional Review Board at medical centers where research may involve radiation exposure of human subjects. The effective dose equivalent concept facilitates evaluation of risk by those who have little or no knowledge of quantities or biological effects of radiation. This paper presents effective dose equivalent data used by radiation workers and those who evaluate human research protocols as these data relate to personal dosimeter reading, entrance skin exposure, and target organ dose. The benefits of using effective dose equivalent to evaluate risk of medical radiation environments and research protocols are also described

  1. Dose and risk evaluation to the thyroid gland in intra-oral dental radiology

    International Nuclear Information System (INIS)

    Souza, Edmilson M.; Lima, Marco A.F.; Kelecom, Alphonse; Correa, Samanda C.A.; Silva, Ademir X.; Brito, Alan

    2008-01-01

    Intra-oral technique is one of the most frequently used procedures of dental radiology, allowing the detection of a variety of dental anomalies such as caries, dental trauma and periodontal lesions, while exposing patients to relatively low doses of radiation. However, although the adverse effects of doses generated by dental radiology are essentially stochastic, a number of epidemiological studies have provided evidence of an increased risk of thyroid tumors for dental radiography. Many studies have measured doses of radiation for dental radiography, but only a few have estimated thyroid dose. Furthermore, most of the studies on dose evaluation in dental radiology are based on standardized calculation phantoms, which neglect the variance of the patient size or even sex. The purpose of this study is to use the Monte Carlo code MCNPX and the FAX (Female Adult voXel) and MAX (Male Adult voXel) phantoms to investigate how absorbed doses to the thyroid gland in intraoral dental examinations vary in female and male patients. The lifetime cancer incidence attributable to dental examinations were estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The phantoms study proved a useful trial for detecting the radiation dose to the thyroid gland and conclusively supported that the anatomy may be regarded as an influencing factor in radiation dose received during dental examination. Finally, the results have also confirmed that the association of the MCNPX code and the MAX and FAX phantoms is very useful in dosimetric studies on radiographic examinations of female and male patients. (author)

  2. Dose rate-dependent marrow toxicity of TBI in dogs and marrow sparing effect at high dose rate by dose fractionation.

    Science.gov (United States)

    Storb, R; Raff, R F; Graham, T; Appelbaum, F R; Deeg, H J; Schuening, F G; Sale, G; Seidel, K

    1999-01-01

    We evaluated the marrow toxicity of 200 and 300 cGy total-body irradiation (TBI) delivered at 10 and 60 cGy/min, respectively, in dogs not rescued by marrow transplant. Additionally, we compared toxicities after 300 cGy fractionated TBI (100 cGy fractions) to that after single-dose TBI at 10 and 60 cGy/min. Marrow toxicities were assessed on the basis of peripheral blood cell count changes and mortality from radiation-induced pancytopenia. TBI doses studied were just below the dose at which all dogs die despite optimal support. Specifically, 18 dogs were given single doses of 200 cGy TBI, delivered at either 10 (n=13) or 60 (n=5) cGy/min. Thirty-one dogs received 300 cGy TBI at 10 cGy/min, delivered as either single doses (n=21) or three fractions of 100 cGy each (n=10). Seventeen dogs were given 300 cGy TBI at 60 cGy/min, administered either as single doses (n=5) or three fractions of 100 cGy each (n=10). Within the limitations of the experimental design, three conclusions were drawn: 1) with 200 and 300 cGy single-dose TBI, an increase of dose rate from 10 to 60 cGy/min, respectively, caused significant increases in marrow toxicity; 2) at 60 cGy/min, dose fractionation resulted in a significant decrease in marrow toxicities, whereas such a protective effect was not seen at 10 cGy/min; and 3) with fractionated TBI, no significant differences in marrow toxicity were seen between dogs irradiated at 60 and 10 cGy/min. The reduced effectiveness of TBI when a dose of 300 cGy was divided into three fractions of 100 cGy or when dose rate was reduced from 60 cGy/min to 10 cGy/min was consistent with models of radiation toxicity that allow for repair of sublethal injury in DNA.

  3. Determining effective radiation mutagen dose for garlic (Allium sativum L.)

    International Nuclear Information System (INIS)

    Taner, Y.; Kunter, B.

    2004-01-01

    This study was carried out to get database for future garlic mutation breeding studies. For this aim, 0, 5, 10, 15, 20, 25 and 30 Gy doses of Cs 137 (gamma-ray) were applied on garlic cloves as a physical mutagen. 50 cloves were used for each dose. Sixty days after treatment, germination rate and shoot development of cloves were determined. The Effective Mutagen Dose (ED 50 ) was calculated by regression analyses. According to the results, 4.455 Gy dose was found to be effective as ED 50 . (author)

  4. Dose and risk evaluation in digital mammography using computer modeling

    International Nuclear Information System (INIS)

    Correa, Samanda Cristine Arruda; Souza, Edmilson Monteiro de; Silva, Humberto de Oliveira; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu; Magalhaes, Sarah Braga

    2010-01-01

    Digital mammography has been introduced in several countries in the last years. The new technology requires new optimising methods considering for instance the increased possibility of changing the absorbed dose, mainly in modern mammographic systems that allow the operator to choose the beam quality by varying the tube voltage, and filter and target materials. In this work, the Monte Carlo code MCNPX is used in order to investigate how the average glandular dose vary with tube voltage (23-32 kV) and anode-filter combination (Mo-Mo,Mo-Rh and Rh-Rh) in digital mammographic examinations. Furthermore, the risk of breast cancer incidence attributable to mammography exams was estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The results show that the risk of breast cancer incidence in women younger than 30 years of age tends to decrease significantly using Rh-Rh anode-filter combination and higher tube voltage. For women older than 50 years of age the variation of tube voltage, and anode-filter combination did not influence the risk values considerably. (author)

  5. Dose and risk evaluation in digital mammography using computer modeling

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Samanda Cristine Arruda; Souza, Edmilson Monteiro de, E-mail: scorrea@nuclear.ufrj.b, E-mail: emonteiro@nuclear.ufrj.b [Centro Universitario Estadual da Zona Oeste (CCMAT/UEZO), Rio de Janeiro, RJ (Brazil); Silva, Humberto de Oliveira, E-mail: hbetorj@gmail.co [Universidade Federal do Rio de Janeiro IF/UFRJ, RJ (Brazil). Inst. de Fisica; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu; Magalhaes, Sarah Braga, E-mail: ademir@nuclear.ufrj.b, E-mail: ricardo@lin.ufrj.b, E-mail: smagalhaes@nuclear.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2010-07-01

    Digital mammography has been introduced in several countries in the last years. The new technology requires new optimising methods considering for instance the increased possibility of changing the absorbed dose, mainly in modern mammographic systems that allow the operator to choose the beam quality by varying the tube voltage, and filter and target materials. In this work, the Monte Carlo code MCNPX is used in order to investigate how the average glandular dose vary with tube voltage (23-32 kV) and anode-filter combination (Mo-Mo,Mo-Rh and Rh-Rh) in digital mammographic examinations. Furthermore, the risk of breast cancer incidence attributable to mammography exams was estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The results show that the risk of breast cancer incidence in women younger than 30 years of age tends to decrease significantly using Rh-Rh anode-filter combination and higher tube voltage. For women older than 50 years of age the variation of tube voltage, and anode-filter combination did not influence the risk values considerably. (author)

  6. Effective dose to patients from thoracic spine examinations with tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus; Soederman, Christina

    2016-01-01

    The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24-0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07-0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm -2 was obtained. (authors)

  7. EFFECTIVE DOSE TO PATIENTS FROM THORACIC SPINE EXAMINATIONS WITH TOMOSYNTHESIS.

    Science.gov (United States)

    Svalkvist, Angelica; Söderman, Christina; Båth, Magnus

    2016-06-01

    The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24-0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07-0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm(-2) was obtained. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Evaluation of the radiation doses to uranium mine employees exposed to external gamma radiation

    International Nuclear Information System (INIS)

    Young, J.G.; Wilson, O.J.

    1983-02-01

    Factors to convert a personal monitor badge reading to an effective dose equivalent are given for several exposure geometries encountered in uranium mines. Factors are also given that relate a free air absorbed dose measurement to an effective dose equivalent. In addition, factors are reported which can be used to estimate the dose equivalent to the testes, ovaries and active bone marrow

  9. A model to incorporate organ deformation in the evaluation of dose/volume relationship

    International Nuclear Information System (INIS)

    Yan, D.; Jaffray, D.; Wong, J.; Brabbins, D.; Martinez, A. A.

    1997-01-01

    Purpose: Measurements of internal organ motion have demonstrated that daily organ deformation exists during the course of radiation treatment. However, a model to evaluate the resultant dose delivered to a daily deformed organ remains a difficult challenge. Current methods which model such organ deformation as rigid body motion in the dose calculation for treatment planning evaluation are incorrect and misleading. In this study, a new model for treatment planning evaluation is introduced which incorporates patient specific information of daily organ deformation and setup variation. The model was also used to retrospectively analyze the actual treatment data measured using daily CT scans for 5 patients with prostate treatment. Methods and Materials: The model assumes that for each patient, the organ of interest can be measured during the first few treatment days. First, the volume of each organ is delineated from each of the daily measurements and cumulated in a 3D bit-map. A tissue occupancy distribution is then constructed with the 50% isodensity representing the mean, or effective, organ volume. During the course of treatment, each voxel in the effective organ volume is assumed to move inside a local 3D neighborhood with a specific distribution function. The neighborhood and the distribution function are deduced from the positions and shapes of the organ in the first few measurements using the biomechanics model of viscoelastic body. For each voxel, the local distribution function is then convolved with the spatial dose distribution. The latter includes also the variation in dose due to daily setup error. As a result, the cumulative dose to the voxel incorporates the effects of daily setup variation and organ deformation. A ''variation adjusted'' dose volume histogram, aDVH, for the effective organ volume can then be constructed for the purpose of treatment evaluation and optimization. Up to 20 daily CT scans and daily portal images for 5 patients with prostate

  10. Dose evaluation for digital X-ray imaging of premature neonates

    International Nuclear Information System (INIS)

    Minkels, T.J.M.; Jeukens, C.R.L.P.N.; Andriessen, P.; Van der Linden, A.N.; Dam, A.J.; Van Straaten, H.L.M.; Cottaar, E.J.E.; Van Pul, C.

    2017-01-01

    X-ray radiography is a commonly used diagnostic method for premature neonates. However, because of higher radiosensitivity and young age, premature neonates are more sensitive to the detrimental effects of ionising radiation. Therefore, it is important to monitor and optimise radiation doses at the neonatal intensive care unit (NICU). The number of X-ray examinations, dose area product (DAP) and effective doses are evaluated for three Dutch NICUs using digital flat panel detectors. Thorax, thorax abdomen and abdomen protocols are included in this study. Median number of examinations is equal to 1 for all three hospitals. Median DAP ranges between 0.05 and 1.02 μGy m2 for different examination types and different weight categories. These examinations result in mean effective doses between 4 ± 4 and 30 ± 10 μSv per examination. Substantial differences in protocols and doses can be observed between hospitals. This emphasises the need for up-to-date reference levels formulated specifically for premature neonates. (authors)

  11. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  12. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    International Nuclear Information System (INIS)

    Cantinha, Rebeca S.; Nakano, Eliana; Silva, Luanna R.S.

    2009-01-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of 60 Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD 50 obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  13. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  14. A system of dose-effects relationships for the Northern wildlife: radiation protection criteria

    International Nuclear Information System (INIS)

    Sazykina, T.G.

    2004-01-01

    The key issue in the assessment system for radiation protection of wildlife is the establishment of a set of dose-effects relationships for reference representatives of natural biota, based on scientific data from a range of doses and a range of radiation effects. Risks to natural populations in particular habitats can be evaluated from a comparison of estimated doses to biota with the scale of dose-effects relationships for different types of biota. Within the frame of the EC Project EPIC 'Environmental Protection from Ionizing Contaminants' 2000-2003), a database has been created, which include the published and unpublished data relating to dose effects relationships for flora and fauna in the Northern and Arctic areas. The EPIC database contains information based exclusively on Russian/FSU experimental and field studies; chronic/lifetime exposures were the focus of the work, owing to the fact that such exposures are the most typical in radiological assessments for biota. In total, the EPIC database radiation effects on biota contains about 1600 records from 440 publications, including datasets on terrestrial and aquatic animals, plants, soil fauna and microorganisms. The EPIC database information cover a very wide range of radiation dose rates to wild flora and fauna: from below 10 -5 Gy d -1 up to more than 1 Gy d -1 . A great variety of radiation effects are registered in the EPIC database, from stimulation at low doses up to death from acute radiation syndrome at high doses. From data, compiled in the EPIC database, the dose-effects relationships were derived for different types of northern organisms. The system of dose-effects relationships forms the scale of severity of radiation effects at increasing levels of chronic radiation exposure. With its focus on the effects of low-to-moderate chronic exposure, the system of dose effects relationships provides a useful tool for scientists and decision-makers to establish safety standards for protecting the

  15. Generation of Composite Dose and Biological Effective Dose (BED) Over Multiple Treatment Modalities and Multistage Planning Using Deformable Image Registration

    International Nuclear Information System (INIS)

    Zhang, Geoffrey; Huang, T-C; Feygelman, Vladimir; Stevens, Craig; Forster, Kenneth

    2010-01-01

    Currently there are no commercially available tools to generate composite plans across different treatment modalities and/or different planning image sets. Without a composite plan, it may be difficult to perform a meaningful dosimetric evaluation of the overall treatment course. In this paper, we introduce a method to generate composite biological effective dose (BED) plans over multiple radiotherapy treatment modalities and/or multistage plans, using deformable image registration. Two cases were used to demonstrate the method. Case I was prostate cancer treated with intensity-modulated radiation therapy (IMRT) and a permanent seed implant. Case II involved lung cancer treated with two treatment plans generated on two separate computed tomography image sets. Thin-plate spline or optical flow methods were used as appropriate to generate deformation matrices. The deformation matrices were then applied to the dose matrices and the resulting physical doses were converted to BED and added to yield the composite plan. Cell proliferation and sublethal repair were considered in the BED calculations. The difference in BED between normal tissues and tumor volumes was accounted for by using different BED models, α/β values, and cell potential doubling times. The method to generate composite BED plans presented in this paper provides information not available with the traditional simple dose summation or physical dose summation. With the understanding of limitations and uncertainties of the algorithms involved, it may be valuable for the overall treatment plan evaluation.

  16. Use of thermoluminescence dosimetry for evaluation of internal beta dose-rate in archaeological dating

    Energy Technology Data Exchange (ETDEWEB)

    Bailiff, I K; Aitken, M J [Oxford Univ. (UK). Research Lab. for Archaeology

    1980-07-01

    An experimental technique is described for the absolute determination of beta dose-rate in pottery. The calibrated system utilizes thermoluminescent dosimeters (natural calcium fluoride) which are located external to the pottery sample. These measurements give an evaluation of the dose-rate at the centre of the pottery that is effectively independent of the relative importance of the thorium, uranium and potassium content (typically 12 ppm Th, 3 ppm U and 1% K/sub 2/O in pottery). This has been checked using analysed uranium, thorium and potassium materials. A dose-rate evaluation may be made after 10-14 d with an accuracy of +-5%, where the dose-rate to the dosimeter is of the order of 0.3 mrad d/sup -1/. Although the background dose-rate due to cosmic radiation and that arising from radioactive impurities in the calcium fluoride is significant (one third), measurements have shown that it may be accurately established. The technique described is to be preferred to other systems used in pottery dating because of its independence of relative radioisotope concentration.

  17. Errors and Uncertainties in Dose Reconstruction for Radiation Effects Research

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Daniel J.

    2008-04-14

    Dose reconstruction for studies of the health effects of ionizing radiation have been carried out for many decades. Major studies have included Japanese bomb survivors, atomic veterans, downwinders of the Nevada Test Site and Hanford, underground uranium miners, and populations of nuclear workers. For such studies to be credible, significant effort must be put into applying the best science to reconstructing unbiased absorbed doses to tissues and organs as a function of time. In many cases, more and more sophisticated dose reconstruction methods have been developed as studies progressed. For the example of the Japanese bomb survivors, the dose surrogate “distance from the hypocenter” was replaced by slant range, and then by TD65 doses, DS86 doses, and more recently DS02 doses. Over the years, it has become increasingly clear that an equal level of effort must be expended on the quantitative assessment of uncertainty in such doses, and to reducing and managing uncertainty. In this context, this paper reviews difficulties in terminology, explores the nature of Berkson and classical uncertainties in dose reconstruction through examples, and proposes a path forward for Joint Coordinating Committee for Radiation Effects Research (JCCRER) Project 2.4 that requires a reasonably small level of effort for DOSES-2008.

  18. Evaluating adherence to ocular hypotensives using the Travatan dosing aid

    Directory of Open Access Journals (Sweden)

    O'Dell L

    2012-01-01

    Full Text Available Leslie O'Dell1, Amy L Hennessy2,3, Alan L Robin2–41May Eye Care Center, Hanover, PA, USA; 2Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA; 3Glaucoma Specialists, Baltimore, MD, USA; 4Wilmer Eye Institute, Johns Hopkins School of Medicine, Baltimore, MD, USAPurpose: The Travatan™ Dosing Aid (TDA is the first commercially available device designed to aid in patients' adherence to their glaucoma therapies and to record patients' eyedrop administration, so that doctors can better assess adherence. No prior studies have objectively evaluated adherence to glaucoma medications and its relationship to the severity of glaucoma or the use of multiple systemic medications.Methods: We enrolled 100 consecutive subjects from a private glaucoma practice, all currently using topical travoprost 0.004%. Each subject was issued a TDA to record the time and date of each drop instilled. Informed consents were signed and the subjects were aware that their medication use was being monitored. Patients returned for follow-up 30–60 days after their initial exam.Results: 89 subjects completed the study: 44 were male, with a mean age of 67 years, and 69.7% were Caucasian. Overall, patient adherence was 74.8% (range 22%–100% improving to 85.4% on the day prior to follow-up. The mean number of missed doses per month was 6.24 ± 5.9. Only 7.9% of the study population never missed a dose and 23.6% ± 4.3% missed more than ten drops per month. No marked association was observed between the severity of glaucoma, race, or the number of systemic medications and adherence. A marked improvement in adherence was noted in patients using travoprost 0.004% as monocular therapy rather than binocular therapy, 84.0% ± 17.1% vs 67.4% ± 23.5% (P < 0.005.Conclusion: Patient adherence to glaucoma medical therapy is a major barrier in the management and treatment of glaucoma patients given the chronic nature and asymptomatic course of the disease. Until recently

  19. Low dose evaluation of the antiandrogen flutamide following a Mode of Action approach

    International Nuclear Information System (INIS)

    Sarrabay, A.; Hilmi, C.; Tinwell, H.; Schorsch, F.; Pallardy, M.; Bars, R.; Rouquié, D.

    2015-01-01

    ABSTRACT: The dose–response characterization of endocrine mediated toxicity is an on-going debate which is controversial when exploring the nature of the dose–response curve and the effect at the low-end of the curve. To contribute to this debate we have assessed the effects of a wide range of dose levels of the antiandrogen flutamide (FLU) on 7-week male Wistar rats. FLU was administered by oral gavage at doses of 0, 0.001, 0.01, 0.1, 1 and 10 mg/kg/day for 28 days. To evaluate the reproducibility, the study was performed 3 times. The molecular initiating event (MIE; AR antagonism), the key events (LH increase, Leydig cell proliferation and hyperplasia increases) and associated events involved in the mode of action (MOA) of FLU induced testicular toxicity were characterized to address the dose response concordance. Results showed no effects at low doses (< 0.1 mg/kg/day) for the different key events studied. The histopathological changes (Leydig cell hyperplasia) observed at 1 and 10 mg/kg/day were associated with an increase in steroidogenesis gene expression in the testis from 1 mg/kg/day, as well as an increase in testosterone blood level at 10 mg/kg/day. Each key event dose–response was in good concordance with the MOA of FLU on the testis. From the available results, only monotonic dose–response curves were observed for the MIE, the key events, associated events and in effects observed in other sex related tissues. All the results, so far, show that the reference endocrine disruptor FLU induces threshold effects in a standard 28-day toxicity study on adult male rats. - Highlights: • Dose–response characterization of endocrine mediated toxicity is an on-going debate. • A wide range of dose levels of flutamide was evaluated on young adult male rats. • Flutamide induces threshold effects using on standard and molecular tools.

  20. Low dose evaluation of the antiandrogen flutamide following a Mode of Action approach

    Energy Technology Data Exchange (ETDEWEB)

    Sarrabay, A. [INSERM, Université Paris-Sud, Faculté de Pharmacie, Châtenay-Malabry (France); UniverSud, INSERM, UMR-996 “Inflammation, Chemokines and Immunopathology”, Châtenay-Malabry (France); Bayer SAS, 16, rue Jean Marie Leclair, 69009 Lyon (France); Hilmi, C.; Tinwell, H.; Schorsch, F. [Bayer SAS, 16, rue Jean Marie Leclair, 69009 Lyon (France); Pallardy, M. [INSERM, Université Paris-Sud, Faculté de Pharmacie, Châtenay-Malabry (France); UniverSud, INSERM, UMR-996 “Inflammation, Chemokines and Immunopathology”, Châtenay-Malabry (France); Bars, R. [Bayer SAS, 16, rue Jean Marie Leclair, 69009 Lyon (France); Rouquié, D., E-mail: david.rouquie@bayer.com [Bayer SAS, 16, rue Jean Marie Leclair, 69009 Lyon (France)

    2015-12-15

    ABSTRACT: The dose–response characterization of endocrine mediated toxicity is an on-going debate which is controversial when exploring the nature of the dose–response curve and the effect at the low-end of the curve. To contribute to this debate we have assessed the effects of a wide range of dose levels of the antiandrogen flutamide (FLU) on 7-week male Wistar rats. FLU was administered by oral gavage at doses of 0, 0.001, 0.01, 0.1, 1 and 10 mg/kg/day for 28 days. To evaluate the reproducibility, the study was performed 3 times. The molecular initiating event (MIE; AR antagonism), the key events (LH increase, Leydig cell proliferation and hyperplasia increases) and associated events involved in the mode of action (MOA) of FLU induced testicular toxicity were characterized to address the dose response concordance. Results showed no effects at low doses (< 0.1 mg/kg/day) for the different key events studied. The histopathological changes (Leydig cell hyperplasia) observed at 1 and 10 mg/kg/day were associated with an increase in steroidogenesis gene expression in the testis from 1 mg/kg/day, as well as an increase in testosterone blood level at 10 mg/kg/day. Each key event dose–response was in good concordance with the MOA of FLU on the testis. From the available results, only monotonic dose–response curves were observed for the MIE, the key events, associated events and in effects observed in other sex related tissues. All the results, so far, show that the reference endocrine disruptor FLU induces threshold effects in a standard 28-day toxicity study on adult male rats. - Highlights: • Dose–response characterization of endocrine mediated toxicity is an on-going debate. • A wide range of dose levels of flutamide was evaluated on young adult male rats. • Flutamide induces threshold effects using on standard and molecular tools.

  1. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  2. Dose-rate effects in external beam radiotherapy redux

    International Nuclear Information System (INIS)

    Ling, C. Clifton; Gerweck, Leo E.; Zaider, Marco; Yorke, Ellen

    2010-01-01

    Recent developments in external beam radiotherapy, both in technical advances and in clinical approaches, have prompted renewed discussions on the potential influence of dose-rate on radio-response in certain treatment scenarios. We consider the multiple factors that influence the dose-rate effect, e.g. radical recombination, the kinetics of sublethal damage repair for tumors and normal tissues, the difference in α/β ratio for early and late reacting tissues, and perform a comprehensive literature review. Based on radiobiological considerations and the linear-quadratic (LQ) model we estimate the influence of overall treatment time on radio-response for specific clinical situations. As the influence of dose-rate applies to both the tumor and normal tissues, in oligo-fractionated treatment using large doses per fraction, the influence of delivery prolongation is likely important, with late reacting normal tissues being generally more sensitive to the dose-rate effect than tumors and early reacting tissues. In conventional fractionated treatment using 1.8-2 Gy per fraction and treatment times of 2-10 min, the influence of dose-rate is relatively small. Lastly, the dose-rate effect in external beam radiotherapy is governed by the overall beam-on-time, not by the average linac dose-rate, nor by the instantaneous dose-rate within individual linac pulses which could be as high as 3 x 10 6 MU/min.

  3. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  4. Evaluation of patient doses from upper gastrointestinal tract examinations based on the dosimetry in an anthropomorphic phantom

    International Nuclear Information System (INIS)

    Hirofuji, Yoshiaki; Aoyama, Takahiko; Koyama, Shuji; Kawaura, Chiyo

    2005-01-01

    The objective of this study was to evaluate organ dose and effective dose to patients from examinations of the upper gastrointestinal (GI) tract. Absorbed doses of various tissues and organs were measured using novel photodiode dosimeters installed in an anthropomorphic phantom representing a standard Japanese adult body. The organ dose and the effective dose were assessed from the absorbed doses according to the definitions seen in the publications of the International Commission on Radiological Protection. Dose measurements were performed for each projection of the upper GI tract examination in seven procedures at four hospitals and in a mobile coach, and organ and effective doses were assessed for each procedure. Organ doses obtained in the observation areas such as the stomach, esophagus and colon were in the order of several to more than 60 mGy, though they decreased to less than 1 mGy for tissues and organs distant from the observation areas. Organ doses and effective doses differed largely according to tube voltage, filtration and tube current or mAs value of the x-ray generator used, and by examination protocol, number of images, fluoroscopy time, and imaging units such as screen/film, computed radiography, digital radiography and flat panel detector. The number of images and the fluoroscopy time were 7 and 1.5 min for the examination in the mobile coach, and 18-22 and 2-6 min in the hospitals. Evaluated effective dose for the examination in the mobile coach was 2.9 mSv, and that in the hospitals ranged from 4.0-13.4 mSv at a ratio of more than three. (author)

  5. Equivalent dose, effective dose and risk assessment from panoramic radiography to the critical organs of head and neck region

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo; Lee, Ae Ryeon

    1995-01-01

    The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. The equivalent and effective dose in adult mode were 837 μSv and 20.93 μSv, those in child mode were 462 μSv and 11.54 μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.2l μSv in adult mode, 20.14 μSv in child mode. From these data, the probabilities of stochastic effect from adult and child mode were 2.50xl0 -6 and 1.47x10 -6 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult. and child mode from these examinations.

  6. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  7. Social-demographic profile and dose evaluation of the radiopharmaceutical facility workers

    International Nuclear Information System (INIS)

    Sanches, Matias P.; Carneiro, Janete C. Gaburo; Sordi, Gian Maria A.A.

    2009-01-01

    The main aims of this work are to identify the social-demographic profile of the workers based on stratification variables such as gender, age, and tasks performed by the workers, and to evaluate the annual collective doses of workers with potential risk of ionizing radiation exposure at the workplace during the years 2004 to 2008. In this context, the knowledge of the workforce composition in the facility responsible for the radioisotope production and its distribution was used. The individual monitoring programme has been carried out by individual dosimeters, TLDs, and internal contamination monitoring (in vivo method). The reported doses, in the period studied, suggest that the external exposure was the main source of occupational exposure in radioisotope production and distribution areas. The internal exposure was not included in the doses estimated, because it was negligible. This study has an important exploratory character, in order to analyze possible correlations related to adverse health effects, aiming to provide directions for occupational epidemiology research. (author)

  8. Evaluation of sphingolipids in Wistar rats treated to prolonged and single oral doses of fumonisin b₁.

    Science.gov (United States)

    Direito, Glória M; Almeida, Adriana P; Aquino, Simone; dos Reis, Tatiana Alves; Pozzi, Claudia Rodrigues; Corrêa, Benedito

    2009-01-01

    The objective of the present study was to evaluate sphingolipid levels (sphingosine-So and sphinganine-Sa) and to compare the Sa/So ratio in liver, serum and urine of Wistar rats after prolonged administration (21 days) of fumonisin B(1) (FB(1)). In parallel, the kinetics of sphingolipid elimination in urine was studied in animals receiving a single dose of FB(1). Prolonged exposure to FB(1) caused an increase in Sa levels in urine, serum and liver. The most marked effect on sphingolipid biosynthesis was observed in animals treated with the highest dose of FB(1). Animals receiving a single dose of FB(1) presented variations in Sa and So levels and in the Sa/So ratio.

  9. Social-demographic profile and dose evaluation of the radiopharmaceutical facility workers

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Matias P.; Carneiro, Janete C. Gaburo; Sordi, Gian Maria A.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: msanches@ipen.br

    2009-07-01

    The main aims of this work are to identify the social-demographic profile of the workers based on stratification variables such as gender, age, and tasks performed by the workers, and to evaluate the annual collective doses of workers with potential risk of ionizing radiation exposure at the workplace during the years 2004 to 2008. In this context, the knowledge of the workforce composition in the facility responsible for the radioisotope production and its distribution was used. The individual monitoring programme has been carried out by individual dosimeters, TLDs, and internal contamination monitoring (in vivo method). The reported doses, in the period studied, suggest that the external exposure was the main source of occupational exposure in radioisotope production and distribution areas. The internal exposure was not included in the doses estimated, because it was negligible. This study has an important exploratory character, in order to analyze possible correlations related to adverse health effects, aiming to provide directions for occupational epidemiology research. (author)

  10. Trends in examination frequency and collective effective doses from computed tomography (CT) procedures in Sudan

    International Nuclear Information System (INIS)

    Yousif, S. B. I.

    2011-01-01

    This study was carried out to estimate the examination frequency and collective dose to population from CT procedures in Sudan. To calculate the annual collective dose from CT examinations a survey was done at 10 hospitals providing data of examinations frequency per day. The data of effective dose have been obtained from pervious study on effective dose per CT examination in Sudan. Then the annual examination frequency and annual collective effective dose had been calculated and discussed providing that the annual collective effective dose from CT examinations is (1482 man.Sv). The highest percentage examination frequency was for head examination (40%). The highest percentage contribution to the total collective dose from CT examinations was for abdomen examinations (32%). The calculated annual examination frequency and annual collective effective dose had been compared with the results of literature and international studies to evaluate the estimated values. The calculated annual collective dose from CT examinations is much lower comparing with the results presented in the literature. The study offers an insight on the examination frequency and the percentage of the risk from different standard radiographic examination within the country. (Author)

  11. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  12. Dose evaluation in special fluoroscopy procedures: Hysterosalpingography and Dacryocystography; Avaliacao de dose em procedimentos especiais de fluoroscopia: histerossalpingografia e dacriocistografia

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Cintya Carolina Barbosa

    2006-04-15

    The hysterosalpingography (HSG) and dacryocystography (DCG) are among the special fluoroscopy procedures. The HSG is a radiodiagnostic technique used to detect uterine and tubal pathologies and it is fundamental for the investigation of infertility. The DCG is a form of lacrimal system imaging, being important to show the level of obstruction, the presence of dilatation of the lacrimal sac, as well as alterations in nearby structures. At this research, the study of skin entrance dose was evaluated for these two special fluoroscopy procedures, besides the analyses of staff doses whose performs the exams. The exams of 22 HSG patients and 8 DCG patients were evaluated using TL-100 dosimeters attached on patient' skin at anatomical landmarks evolved on each exam. In the case of HSG, the results showed that skin entrance doses varied from 0.5 mGy to 73.4 mGy, with an average value of 22.1 mGy. The estimated uterus dose was 5.5 mGy, and 6.6 mGy was the average dose estimated to the ovaries. The patient' skin entrance dose undergoing to DCG examinations varied from 2.1 mGy to 10.6 mGy, and the average eye's dose was 6.1 mGy. The results of staff dose showed that, on HSG, the average dose on doctor's right hand was 4.3 mGy per examination. This value had to the fact that the physician introduces the contrast manually while all contrast exposures. In relation of DCG, the staff's dose values were nearby background radiation, evidencing that, inside of permitted limits, there is no risk for the physicians at this procedure. (author)

  13. In vitro and in vivo effects of low dose HTO contamination modulated by dose rate

    International Nuclear Information System (INIS)

    Petcu, I.; Savu, D.; Moisoi, N.; Koeteles, G.J.

    1997-01-01

    The experiment performed in vitro intended to examine whether an adaptive response could be elicited on lymphocytes by low-level contamination of whole blood with tritiated water and if the modification of the dose rate has any influence on it. Lymphocytes pre-exposed to 3 HOH (0.2 - 6.6 MBq/ml) and subsequently irradiated with I Gy γ-rays showed micronuclei frequency significantly lower (40% - 45%) than the expected member (sum of the yields induced by 3 HOH and γ-rays separately). The degree of the radioresistance induced by HTO pre-treatments became higher with decreasing dose-rate for a rather similar total adapting dose. In vivo, the aim of the study was to investigate if different dose rates are inducing modulation of the lipid peroxidation level and of the thymidine uptake in different tissues of animals contaminated by HTO ingestion. The total doses varied between 5 and 20 cGy and were delivered as chronic (100 days) or acute contamination (5 days). It was observed that only doses about 20 cGy caused a dose-rate dependent increase of the lipid peroxidation level in the tissues of small intestine, kidney and spleen. Both chronic and acute contamination did produce reduced incorporation of thymidine in the cells of bone marrow. The most effective decrease of thymidine uptake was induced by the acute contamination in the lower dose domain (approx. 5 cGy). Our hypothesis is that in this dose domain the modification of thymidine uptake could be due to changes at the level of membrane transport. (author)

  14. Committed effective doses at various times after intakes of radionuclides

    CERN Document Server

    Phipps, A W; Kendall, G M; Silk, T J; Stather, J W

    1991-01-01

    This report contains details of committed effective doses at nine times after intake from intakes by ingestion and inhalation of 1 mu 1 AMAD particles by adults. Data are given for various chemical forms of 359 nuclides. It complements NRPB-R245 which describes the changes which have taken place since the last NRPB compendium of dose per unit intake factors (dose coefficients) and gives summary tables. Information on committed equivalent doses to organs is given in NRPB-M288. The information given in these memoranda is also available as a microcomputer package - NRPB-SR245.

  15. Incremental cost and cost-effectiveness of low-dose, high-frequency training in basic emergency obstetric and newborn care as compared to status quo: part of a cluster-randomized training intervention evaluation in Ghana.

    Science.gov (United States)

    Willcox, Michelle; Harrison, Heather; Asiedu, Amos; Nelson, Allyson; Gomez, Patricia; LeFevre, Amnesty

    2017-12-06

    Low-dose, high-frequency (LDHF) training is a new approach best practices to improve clinical knowledge, build and retain competency, and transfer skills into practice after training. LDHF training in Ghana is an opportunity to build health workforce capacity in critical areas of maternal and newborn health and translate improved capacity into better health outcomes. This study examined the costs of an LDHF training approach for basic emergency obstetric and newborn care and calculates the incremental cost-effectiveness of the LDHF training program for health outcomes of newborn survival, compared to the status quo alternative of no training. The costs of LDHF were compared to costs of traditional workshop-based training per provider trained. Retrospective program cost analysis with activity-based costing was used to measure all resources of the LDHF training program over a 3-year analytic time horizon. Economic costs were estimated from financial records, informant interviews, and regional market prices. Health effects from the program's impact evaluation were used to model lives saved and disability-adjusted life years (DALYs) averted. Uncertainty analysis included one-way and probabilistic sensitivity analysis to explore incremental cost-effectiveness results when fluctuating key parameters. For the 40 health facilities included in the evaluation, the total LDHF training cost was $823,134. During the follow-up period after the first LDHF training-1 year at each participating facility-approximately 544 lives were saved. With deterministic calculation, these findings translate to $1497.77 per life saved or $53.07 per DALY averted. Probabilistic sensitivity analysis, with mean incremental cost-effectiveness ratio of $54.79 per DALY averted ($24.42-$107.01), suggests the LDHF training program as compared to no training has 100% probability of being cost-effective above a willingness to pay threshold of $1480, Ghana's gross national income per capita in 2015. This

  16. The Effect of NPP's Stack Height to Radiation Dose

    International Nuclear Information System (INIS)

    Pandi, Liliana Yetta; Rohman, Budi

    2003-01-01

    The purpose of dose calculation for accidents is to analyze the capability of NPP to maintain the safety of public and workers in case an accident occurs on the Plant in a site. This paper calculates the Loss of Coolant Accident in PWR plant. The calculation results shows that no risks of serious radiation exposure are given to the neighboring public even if such a large accident occurred, and the effect of stack height can be predicted by analysis of the calculation results. The whole dose is calculated for some location (100 m, 300 m, 500 m, 700 m, 900 m, 1500 m, and 2000 m) with three difference stack height i.e. 0 m, 40 m and 100 m. The result of the whole dose calculation is under permitted criteria for whole dose : 0.25 Sv and thyroid dose : 3.0 Sv. The calculation of radiation dose in this paper use EEDCDQ code

  17. CARCINOGENIC EFFECTS OF LOW DOSES OF IONIZING RADIATION

    Science.gov (United States)

    Carcinogenic Effects of Low Doses of Ionizing RadiationR Julian Preston, Environmental Carcinogenesis Division, NHEERL, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711The form of the dose-response curve for radiation-induced cancers, particu...

  18. Biological effects of low-dose ionizing radiation exposure

    International Nuclear Information System (INIS)

    Reinoehl-Kompa, Sabine; Baldauf, Daniela; Heller, Horst

    2009-01-01

    The report on the meeting of the Strahlenschutzkommission 2007 concerning biological effects of low-dose ionizing radiation exposure includes the following contributions: Adaptive response. The importance of DNA damage mechanisms for the biological efficiency of low-energy photons. Radiation effects in mammography: the relative biological radiation effects of low-energy photons. Radiation-induced cataracts. Carcinomas following prenatal radiation exposure. Intercellular apoptosis induction and low-dose irradiation: possible consequences for the oncogenesis control. Mechanistic models for the carcinogenesis with radiation-induced cell inactivation: application to all solid tumors in the Japanese atomic bomb survivors. Microarrays at low radiation doses. Mouse models for the analysis of biological effects of low-dose ionizing radiation. The bystander effect: observations, mechanisms and implications. Lung carcinoma risk of Majak workers - modeling of carcinogenesis and the bystander effect. Microbeam studies in radiation biology - an overview. Carcinogenesis models with radiation-induced genomic instability. Application to two epidemiological cohorts.

  19. Biological effect of Pulsed Dose Rate brachytherapy with stepping sources

    International Nuclear Information System (INIS)

    Limbergen, Erik F.M. van; Fowler, Jack F.

    1996-01-01

    Purpose: To explore the possible increase of radiation effect in tissues irradiated by pulsed brachytherapy (PDR), for local tissue dose-rates between those 'averaged over the whole pulse' and the instantaneous high dose rates close to the dwell positions. An earlier publication (Fowler and Mount 1992) had shown that, for dose rates (averaged for the duration of the pulse) up to 3 Gy/h, little change of isoeffect doses from continuous low dose rate (CLDR) are expected, unless larger doses per fraction than 1 Gy are used, and especially if components of very rapid repair are present with half-times of less than about 0.5 hours. However, local and transient dose rates close to stepping sources can be up to several Gy per minute. Methods: Calculations were done assuming the linear quadratic formula for radiation damage, in which only the dose-squared term is subject to repair, at a constant exponential rate. The formula developed by Dale for fractionated low-dose-rate radiotherapy was used. A constant overall time of 140 hours and constant total dose of 70 Gy were assumed throughout, the continuous low dose-rate of 0.5 Gy/h (CLDR) providing the unitary standard effects for each PDR condition. Effects of dose-rates ranging from 4 Gy/h to 120 Gy/h (HDR at 2 Gy/min) were studied, and T (1(2)) from 4 minutes to 1.5 hours. Results: Curves are presented relating the ratio of increased biological effect (proportional to log cell kill) calculated for PDR relative to CLDR. Ratios as high as 1.5 can be found for large doses per pulse (> 1 Gy) at high instantaneous dose-rates if T (1(2)) in tissues is as short as a few minutes. The major influences on effect are dose per pulse, half-time of repair in the tissue, and - when T (1(2)) is short - the instantaneous dose-rate. Maximum ratios of PDR/CLDR effect occur when the dose-rate is such that pulse duration is approximately equal to T (1(2)) of repair. Results are presented for late-responding tissues, the differences from CLDR

  20. Building shielding effects on radiation doses from routine radionuclide releases

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1977-01-01

    In calculating population doses from the release of radionuclides to the atmosphere, it is usually assumed that man spends all of his time outdoors standing on a smooth infinite plane. Realistically, however, man spends most of the time indoors, so that substantial reductions in radiation doses may result compared with the usual estimates. Calculational models were developed to study the effects of building structures on radiation doses from routine releases of radionuclides to the atmosphere. Both internal dose from inhaled radionuclides and external photon dose from airborne and surface-deposited radionuclides are considered. The effect of building structures is described quantitatively by a dose reduction factor, which is the ratio of the dose inside a structure to the corresponding dose with no structure present. The internal dose from inhaled radionuclides is proportional to the radionuclide concentration in the air. Assuming that the outdoor airborne concentration is constant with time, the time-dependence of the indoor airborne concentration in terms of the structure air ventilation rate, the deposition velocities for radionuclides on the inside floor, walls, and ceiling, and the radioactive decay constant, were calculated

  1. Evaluation of glandular dose in conventional and digital mammography systems

    International Nuclear Information System (INIS)

    Coutinho, Celia Maria Campos

    2009-01-01

    A survey was conducted to estimate the average glandular dose (D g ) for patients undergoing mammography and to report the distribution of incident air kerma (K i ), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, K i and D g were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean K i value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean D g value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of K i and D g between mammography systems showed significant effect of their technical characteristics (p i and D g , it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)

  2. Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning.

    Science.gov (United States)

    Chamberland, Eve; Beaulieu, Luc; Lachance, Bernard

    2015-05-08

    The purpose of this study is to evaluate the accuracy of the electron Monte Carlo (eMC) dose calculation algorithm included in a commercial treatment planning system and compare its performance against an electron pencil beam algorithm. Several tests were performed to explore the system's behavior in simple geometries and in configurations encountered in clinical practice. The first series of tests were executed in a homogeneous water phantom, where experimental measurements and eMC-calculated dose distributions were compared for various combinations of energy and applicator. More specifically, we compared beam profiles and depth-dose curves at different source-to-surface distances (SSDs) and gantry angles, by using dose difference and distance to agreement. Also, we compared output factors, we studied the effects of algorithm input parameters, which are the random number generator seed, as well as the calculation grid size, and we performed a calculation time evaluation. Three different inhomogeneous solid phantoms were built, using high- and low-density materials inserts, to clinically simulate relevant heterogeneity conditions: a small air cylinder within a homogeneous phantom, a lung phantom, and a chest wall phantom. We also used an anthropomorphic phantom to perform comparison of eMC calculations to measurements. Finally, we proceeded with an evaluation of the eMC algorithm on a clinical case of nose cancer. In all mentioned cases, measurements, carried out by means of XV-2 films, radiographic films or EBT2 Gafchromic films. were used to compare eMC calculations with dose distributions obtained from an electron pencil beam algorithm. eMC calculations in the water phantom were accurate. Discrepancies for depth-dose curves and beam profiles were under 2.5% and 2 mm. Dose calculations with eMC for the small air cylinder and the lung phantom agreed within 2% and 4%, respectively. eMC calculations for the chest wall phantom and the anthropomorphic phantom also

  3. Whole body effective dose measurements in a fan beam bone mineral densitometer, Lunar expert

    Energy Technology Data Exchange (ETDEWEB)

    Sathiakumar, C.; Griffiths, M.; Cross, P.; Pocock, N.; Freund, J. [St Vincents Hospital, Sydney, NSW (Australia) Department of Nuclear Medicine; Kron, T.; Duggan, L. [Newcastle Mater Misericordiae Hospital, Newcastle, NSW (Australia). Department of Radiation Oncology; Holley, L. [University of Technology, Sydney, NSW (Australia). Department of Health Services

    1998-06-01

    Full text: The most recent generation of DXA machines employ a fan beam geometry and high resolution imaging detector, resulting in decreased scanning time and increased image resolution compared to previous rectilinear scanners, but with higher radiation burden to the patient because of an increasing number of bone mineral density scans, it was felt that independent evaluation of the radiation dose was necessary. The whole body effective dose for an AP lumbar spine scan and femur scan using the EXPERT bone densitometer was calculated for the fast and turbo scanning modes, using thermoluminescence dosimetry (TLD). A method was developed to determine the absorbed dose of the irradiated volume of an organ by summing the dose for each of the coronal areas, which results in a volume dose. The Whole Body Effective dose for AP lumbar spine fast scanning mode is 84.1 {mu}Sv and turbo scanning mode is 56.4 {mu}Sv. The Whole Body Effective dose for femur fast scanning mode is 6.6 {mu}Sv and turbo scanning mode is 4.2 {mu}Sv, with no ovary exposure. A theoretical method has been developed to calculate the organ dose from which whole body effective dose was calculated

  4. Adult head CT scans: the uncertainties of effective dose estimates

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Full Text: CT scanning is a high dose imaging modality. Effective dose estimates from CT scans can provide important information to patients and medical professionals. For example, medical practitioners can use the dose to estimate the risk to the patient, and judge whether this risk is outweighed by the benefits of the CT examination, while radiographers can gauge the effect of different scanning protocols on the patient effective dose, and take this into consideration when establishing routine scan settings. Dose estimates also form an important part of epidemiological studies examining the health effects of medical radiation exposures on the wider population. Medical physicists have been devoting significant effort towards estimating patient radiation doses from diagnostic CT scans for some years. The question arises: How accurate are these effective dose estimates? The need for a greater understanding and improvement of the uncertainties in CT dose estimates is now gaining recognition as an important issue (BEIR VII 2006). This study is an attempt to analyse and quantify the uncertainty components relating to effective dose estimates from adult head CT examinations that are calculated with four commonly used methods. The dose estimation methods analysed are the Nagel method, the ImpaCT method, the Wellhoefer method and the Dose-Length Product (DLP) method. The analysis of the uncertainties was performed in accordance with the International Standards Organisation's Guide to the Expression of Uncertainty in Measurement as discussed in Gregory et al (Australas. Phys. Eng. Sci. Med., 28: 131-139, 2005). The uncertainty components vary, depending on the method used to derive the effective dose estimate. Uncertainty components in this study include the statistical and other errors from Monte Carlo simulations, uncertainties in the CT settings and positions of patients in the CT gantry, calibration errors from pencil ionization chambers, the variations in the organ

  5. Topics on study of low dose-effect relationship

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Takeshi [Toho Univ., School of Medicine, Tokyo (Japan); Ohyama, Harumi

    1999-09-01

    It is not exceptional but usually observed that a dose-effect relationship in biosystem is not linear. Sometimes, the low dose-effect relationship appears entirely contrary to the expectation from high dose-effect. This is called a 'hormesis' phenomena. A high dose irradiation inflicts certainly an injury on biosystem. No matter how low the dose may be, an irradiation might inflict some injury on biosystem according to Linear Non-Threshold hypothesis(LNT). On the contrary to the expectation, a low dose irradiation stimulates immune system, and promotes cell proliferation. This is called 'radiation hormesis'. The studies of the radiation hormesis are made on from four points of view as follows: (1) radiation adaptive response, (2) revitalization caused by a low dose stimulation, (3) a low dose response unexpected from the LNT hypothesis, (4) negation of the LNT hypothesis. The various empirical proofs of radiation hormesis are introduced in the report. (M . Suetake)

  6. Patient radiation exposure dose evaluation of whole spine scanography due to exposure direction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam [Dept. of Bio-convergence Engineering, Graduate School of Korea University, Seoul (Korea, Republic of); Kwon, Soon Mu [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, Korea University, Seoul (Korea, Republic of)

    2015-04-15

    Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefore we need to redefine of protocol for digital radiography such as WSS, whole spine scanography, effective dose, patient exposure dose, exposure direction, protocol optimization.

  7. Towards a new dose and dose-rate effectiveness factor (DDREF)? Some comments.

    Science.gov (United States)

    Chadwick, K H

    2017-06-26

    The aim of this article is to offer a broader, mechanism-based, analytical tool than that used by (Rühm et al 2016 Ann. ICRP 45 262-79) for the interpretation of cancer induction relationships. The article explains the limitations of this broader analytical tool and the implications of its use in view of the publications by Leuraud et al 2015 (Lancet Haematol. 2 e276-81) and Richardson et al 2015 (Br. Med. J. 351 h5359). The publication by Rühm et al 2016 (Ann. ICRP 45 262-79), which is clearly work in progress, reviews the current status of the dose and dose-rate effectiveness factor (DDREF) as recommended by the ICRP. It also considers the issues which might influence a reassessment of both the value of the DDREF as well as its application in radiological protection. In this article, the problem is approached from a different perspective and starts by commenting on the limited scientific data used by Rühm et al 2016 (Ann. ICRP 45 262-79) to develop their analysis which ultimately leads them to use a linear-quadratic dose effect relationship to fit solid cancer mortality data from the Japanese life span study of atomic bomb survivors. The approach taken here includes more data on the induction of DNA double strand breaks and, using experimental data taken from the literature, directly relates the breaks to cell killing, chromosomal aberrations and somatic mutations. The relationships are expanded to describe the induction of cancer as arising from radiation induced cytological damage coupled to cell killing since the cancer mutated cell has to survive to express its malignant nature. Equations are derived for the induction of cancer after both acute and chronic exposure to sparsely ionising radiation. The equations are fitted to the induction of cancer in mice to illustrate a dose effect relationship over the total dose range. The 'DDREF' derived from the two equations varies with dose and the DDREF concept is called into question. Although the equation for

  8. Estimation of effective dose equivalente from external irradiations

    International Nuclear Information System (INIS)

    Wakabayashi, T.

    1985-07-01

    A methodology for computing effective dose equivalent, derived from the computer code ALGAM: Monte Carlo Estimation of Internal Dose from Gamma-ray Sources in a Phantom Man, developed at Oak Ridge National Laboratory, is presented. The modified code was run for 12 different photon energy levels, from 0,010 Mev to 4.0 Mev, which provides computing the absorved dose, for these energy levels, in each one of the 97 organs of the original code. The code also was run for the principal energy levels used in the calibration of the dosimetric films. The results of the absorved doses per photon obtained for these levels of energy have been transformed in effective dose equivalents. (M.A.C.) [pt

  9. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    CERN Document Server

    Nakamura, T; Tonoike, K

    2003-01-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose b...

  10. Effective dose for patient in multimode panoramic radiography

    International Nuclear Information System (INIS)

    Yasaki, Shiro; Daibo, Motoji

    1999-01-01

    In recent years, multimode panoramic radiography has had various functions, such as the auto exposure function, auto focus function (auto function), TMJ radiography and tomogram radiography functions. The purpose of this study was to estimate the effective dose for patients in each mode of the new multimode panoramic radiography (J. MORITA MFG. CORP. Dental Panorama X-ray Apparatus: Veraview Scope X 600). The absorbed doses in important organs involved in the causation of stochastic effects were measured by a thermoluminescent dosimeter using RANDO phantom. The effective doses were calculated using modified tissue weighting factors recommended by the International Commission on Radiological Protection (ICRP) in 1999. The mean field size over skin in typical panoramic and tomographic examinations was about 3% and 0.4% of the total body surface area of 15000 cm 2 . Assuming that the incidence of skin cancer is proportional to the area of skin exposed to ionizing radiation, the tissue weighting factor of skin can be estimated to be about 0.0003 and 0.00004. The estimate in effective dose was lower (5.3 μSv) in the panoramic auto function mode (an average exposure condition of 69 kV 7 mA) than that (6.5-13.8 μSv) in the linear tomogram modes. Since the linear tomogram mode requires a scout view, such as standard panoramic radiography, the dose in the linear tomogram mode becomes higher than other modes. A percentage of gonad doses in effective doses was negligible. (author)

  11. UV-radiation and skin cancer dose effect curves

    International Nuclear Information System (INIS)

    Henriksen, T.; Dahlback, A.; Larsen, S.H.

    1988-08-01

    Norwegian skin cancer data were used in an attempt to arrive at the dose effect relationship for UV-carcinogenesis. The Norwegian population is relatively homogenous with regard to skin type and live in a country where the annual effective UV-dose varies by approximately 40 percent. Four different regions of the country, each with a broadness of 1 o in latitude (approximately 111 km), were selected . The annual effective UV-doses for these regions were calculated assuming normal ozone conditions throughout the year. The incidence of malignant melanoma and non-melanoma skin cancer (mainly basal cell carcinoma) in these regions were considered and compared to the annual UV-doses. For both these types of cancer a quadratic dose effect curve seems to be valid. Depletions of the ozone layer results in larger UV-doses which in turn may yield more skin cancer. The dose effect curves suggest that the incidence rate will increase by an ''amplification factor'' of approximately 2

  12. Proactively evaluating training effectiveness

    International Nuclear Information System (INIS)

    Fetterman, Harry E.

    2003-01-01

    A common model of the five phase Systematic Approach to Training (SAT) displays the fifth phase, evaluation, feeding back into the previous four phases: analysis, design, development, and implementation. Evaluating training effectiveness in PP and L's Nuclear Department is not simply the fifth phase of the SAT. PP and L has demonstrated a more effective methodology is realized when evaluation is built into each of the other four phases. At PP and L, evaluation is conducted formatively throughout the first four phases of the SAT process and summatively after implementation. (author)

  13. Dose evaluation of TPS according to treatment sites in IMRT

    International Nuclear Information System (INIS)

    Kim, Jin Man; Kim, Jong Sik; Hong, Chae Seon; Park, Ju Young; Park, Su Yeon; Ju, Sang Gyu

    2013-01-01

    This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as Pinnacle 3 (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made

  14. Effect of low-dose irradiation on pregnant mouse haemopoiesis

    International Nuclear Information System (INIS)

    Weinberg, S.R.; McCarthy, E.G.; MacVittie, T.J.; Baum, S.J.

    1981-01-01

    The effects of low-dose gamma radiation to haemopoietic progenitor cell compartments of the marrow and spleen of virgin female mice and pregnant mice were studied. Microplasma clot cultures were used to assess burst-forming uniterythroid (BFU-E) and colony-forming unit-erythroid (CFU-E) activity, and double-layer agar cultures were established to evaluate granulocyte-macrophage colony-forming cell (GM-CFC) and macrophage colony-forming cell (M-CFC). The apparent shift in maternal erythropoiesis from the bone marrow to the enlarged spleen was reflected by an increase in CFU-E and BFU-E per spleen and a concomitant decrease in CFU-E and BFU-E per femur. Whereas maternal GM-CFC values per femur increased 36%, maternal GM-CFC per spleen increased by 172% compared to virgin values. Total-body irradiation to the day-10.5 pregnant mouse caused a further suppression of day-14.5 medullary erythropoiesis (i.e. decreased CFU-E values) compared to the virgin female mouse. An ability of the maternal spleen to support further compensatory erythropoiesis following increasing doses of radiation was demonstrated. Four days after 1.0 Gy exposure, maternal values for GM-CFC per femur or spleen decreased to nonirradiated virgin mice values. M-CFC per maternal femur decreased to nonirradiated virgin mice values. M-CFC per maternal femur decreased following 1.5 Gy, but M-CFC per spleen appeared to be unaffected with doses from 0.5 to 2.0 Gy. (author)

  15. Health effects of low doses at low dose rates: dose-response relationship modeling in a cohort of workers of the nuclear industry

    International Nuclear Information System (INIS)

    Metz-Flamant, Camille

    2011-01-01

    The aim of this thesis is to contribute to a better understanding of the health effects of chronic external low doses of ionising radiation. This work is based on the French cohort of CEA-AREVA NC nuclear workers. The mains stages of this thesis were (1) conducting a review of epidemiological studies on nuclear workers, (2) completing the database and performing a descriptive analysis of the cohort, (3) quantifying risk by different statistical methods and (4) modelling the exposure-time-risk relationship. The cohort includes monitored workers employed more than one year between 1950 and 1994 at CEA or AREVA NC companies. Individual annual external exposure, history of work, vital status and causes of death were reconstructed for each worker. Standardized mortality ratios using French national mortality rates as external reference were computed. Exposure-risk analysis was conducted in the cohort using the linear excess relative risk model, based on both Poisson regression and Cox model. Time dependent modifying factors were investigated by adding an interaction term in the model or by using exposure time windows. The cohort includes 36, 769 workers, followed-up until age 60 in average. During the 1968- 2004 period, 5, 443 deaths, 2, 213 cancers, 62 leukemia and 1, 314 cardiovascular diseases were recorded. Among the 57% exposed workers, the mean cumulative dose was 21.5 milli-sieverts (mSv). A strong Healthy Worker Effect is observed in the cohort. Significant elevated risks of pleura cancer and melanoma deaths were observed in the cohort but not associated with dose. No significant association was observed with solid cancers, lung cancer and cardiovascular diseases. A significant dose-response relationship was observed for leukemia excluding chronic lymphatic leukemia, mainly for doses received less than 15 years before and for yearly dose rates higher than 10 mSv. This PhD work contributes to the evaluation of risks associated to chronic external radiation

  16. Effective doses to family members of patients treated with radioiodine 131

    International Nuclear Information System (INIS)

    Kocovska, Marina Zdravevska; Ristevska, Svetlana Micevska; Nikolovski, Sasho; Jokic, Vesna Spasic

    2010-01-01

    The purpose of this study was to evaluate the effective dose to family members of thyroid cancer and hyperthyroid patients treated with radioiodine 131; also to compare the results with dose constraints proposed by International Commission of Radiological Protection (ICRP) and Basic Safety Standards (BSS) of the International Atomic Energy Agency (IAEA). Material and methods: for estimation of effective doses at sixty family members of thirty thyroid cancer and thirty hyperthyroid patients treated with radioiodine 131, the thermoluminescent dosimeters, Model TLD 100, were used. Thyroid cancer patients were hospitalized for three days, while hyperthyroid patients were treated on out-patient basis. The family members wore thermoluminescent dosimeter in front of the torso for seven days. Results: The radiation doses to family members of thyroid cancer patients were well below recommended dose constraint of 1 mSv. The mean value of effective dose was 0.21 mSv (min 0.02 - max 0.51 mSv). Effective doses, higher than 1 mSv, were detected at 11 family members of hyperthyroid patients.. The mean value of effective dose at family members of hyperthyroid patients was 0.87 mSv (min 0.12 - max 6.79) Conclusion: After three days of hospitalization and detailed given oral and written instruction, thyroid carcinoma patients maintain not to exceed the proposed dose limits. Hyperthyroid patients present a greater radiation hazard than thyroid carcinoma patients. The estimated effective doses were higher than the effective doses at family members of thyroid carcinoma patients. These findings may be considered when establishing new national guidelines concerning radiation protection and release of patients after a treatment with radioiodine therapy.(Author)

  17. Effect of a therapeutic dose of pseudoephedrine on swimmers ...

    African Journals Online (AJOL)

    is thought to result from direct stimulation of post-synaptic receptors and inhibition ..... optimal effect could be extensive with the use of nutritional supplements; therefore ... These studies support the theory that higher doses of PSE may result in.

  18. Radiation effects after low dose chronic long-term exposure

    International Nuclear Information System (INIS)

    Fliedner, T.M.; Friesecke, I.

    1997-01-01

    This document approaches the radiation effects after low dose chronic long-term exposure, presenting examples occurred, the pathophysiologic mechanisms for cell system tolerance in elevated radiation fields, and the diagnostic and therapeutic possibilities

  19. A double-blind, placebo-controlled, randomised, parallel-group, dose-escalating, repeat dose study in healthy volunteers to evaluate the safety, tolerability, pharmacodynamic effects and pharmacokinetics of the once daily rectal application of NRL001 suppositories for 14 days.

    Science.gov (United States)

    Bell, D; Duffin, A; Jacobs, A; Pediconi, C; Gruss, H J

    2014-03-01

    The 1R,2S stereoisomer of methoxamine hydrochloride, NRL001, is a highly selective α1-adrenoceptor agonist being developed for the local treatment of non-structural faecal incontinence caused by weak internal anal sphincter tone. This study investigated the steady state pharmacokinetics (PK) and safety of 2 g rectal suppositories containing NRL001 in different strengths (7.5, 10, 12.5 or 15 mg). Healthy volunteers aged 18-45 years received 14 daily doses of NRL001 2 g suppositories or matching placebo. In each dose group nine participants received NRL001 and three received placebo. Blood samples to determine NRL001 concentrations were taken on Days 1, 7 and 14. Cardiovascular parameters were collected via electrocardiograms, Holter monitoring (three lead Holter monitor) and vital signs. Forty-eight volunteers were enrolled; 43 completed the study and were included in the PK analysis population. AUC and Cmax broadly increased with increasing dose, Tmax generally occurred between 4.0 and 5.0 h. Although the data did not appear strongly dose proportional, dose proportionality analysis did not provide evidence against dose proportionality as the log(dose) coefficients were not significantly < 1. NRL001 did not accumulate over time for any dose. Increasing NRL001 concentrations were related to changes in vital sign variables, most notably decreased heart rate. The most commonly reported adverse events (AEs) in the active treatment groups were paraesthesia and piloerection. Treatment with NRL001 was generally well tolerated over 14 days once daily dosing and plasma NRL001 did not accumulate over time. Treatment was associated with changes in vital sign variables, most notably decreased heart rate. AEs commonly reported with NRL001 treatment were events indicative of a systemic α-adrenergic effect. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  20. SU-F-T-474: Evaluation of Dose Perturbation, Temperature and Sensitivity Variation With Accumulated Dose of MOSFET Detector

    Energy Technology Data Exchange (ETDEWEB)

    Ganesan, B; Prakasarao, A; Singaravelu, G [Anna University, Chennai, TamilNadu (India); Palraj, T; Rai, R [Dr. Rai Memorial Cancer Institute, Chennai, TamilNadu (India)

    2016-06-15

    Purpose: The use of mega voltage gamma and x-ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin. However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin. Methods: To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap. To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere. In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGy Results: the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution. The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C. The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized. This work investigates the dual-bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams. Conclusion: From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.. It is observed that the build-up influences the temperature dependency of MOSFET and causes some uncertainty in the readings. In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.

  1. SU-F-T-474: Evaluation of Dose Perturbation, Temperature and Sensitivity Variation With Accumulated Dose of MOSFET Detector

    International Nuclear Information System (INIS)

    Ganesan, B; Prakasarao, A; Singaravelu, G; Palraj, T; Rai, R

    2016-01-01

    Purpose: The use of mega voltage gamma and x-ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin. However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin. Methods: To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap. To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere. In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGy Results: the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution. The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C. The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized. This work investigates the dual-bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams. Conclusion: From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.. It is observed that the build-up influences the temperature dependency of MOSFET and causes some uncertainty in the readings. In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.

  2. Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Luerman, Christine M.; Sowards, Keith T.

    2009-01-01

    Recently, several different models of 125 I and 103 Pd brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of 125 I and 103 Pd sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for 125 I and the Theragenics model 200 seed for 103 Pd using the same implant scheme.

  3. Radiation doses and correlated late effects in diagnostic radiology

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1980-04-01

    Patient irradiation in diagnostic radiology was estimated from measurements of absorbed doses in different organs, assessment of the energy imparted and retrospective calculations based on literature data. Possible late biological effects, with special aspects on children, were surveyed. The dose to the lens of the eye and the possibility of shielding in carotid angiography was studied as was the absorbed dose to the thyroid gland at cardiac catheterization and angiocardiography in children. Calculations of the mean bone marrow dose and gonad doses were performed in children with chronic skeletal disease revealing large contributions from examinations of organs other than the skeleton. The dose distribution in the breast in mammography was investigated. Comparison of the energy imparted in common roentgen examinations in 1960 and 1975 showed an unexpected low decrease in spite of technical improvements. Reasons for the failing decrease are discussed. The energy imparted to children in urological examinations was reduced significantly due to introduction of high sensitivity screens and omission of dose demanding projections. Contributions to the possible late effects were estimated on the basis of the organ doses assessed. (author)

  4. Dose-to-medium vs. dose-to-water: Dosimetric evaluation of dose reporting modes in Acuros XB for prostate, lung and breast cancer

    Directory of Open Access Journals (Sweden)

    Suresh Rana

    2014-12-01

    Full Text Available Purpose: Acuros XB (AXB dose calculation algorithm is available for external beam photon dose calculations in Eclipse treatment planning system (TPS. The AXB can report the absorbed dose in two modes: dose-to-water (Dw and dose-to-medium (Dm. The main purpose of this study was to compare the dosimetric results of the AXB_Dm with that of AXB_Dw on real patient treatment plans. Methods: Four groups of patients (prostate cancer, stereotactic body radiation therapy (SBRT lung cancer, left breast cancer, and right breast cancer were selected for this study, and each group consisted of 5 cases. The treatment plans of all cases were generated in the Eclipse TPS. For each case, treatment plans were computed using AXB_Dw and AXB_Dm for identical beam arrangements. Dosimetric evaluation was done by comparing various dosimetric parameters in the AXB_Dw plans with that of AXB_Dm plans for the corresponding patient case. Results: For the prostate cancer, the mean planning target volume (PTV dose in the AXB_Dw plans was higher by up to 1.0%, but the mean PTV dose was within ±0.3% for the SBRT lung cancer. The analysis of organs at risk (OAR results in the prostate cancer showed that AXB_Dw plans consistently produced higher values for the bladder and femoral heads but not for the rectum. In the case of SBRT lung cancer, a clear trend was seen for the heart mean dose and spinal cord maximum dose, with AXB_Dw plans producing higher values than the AXB_Dm plans. However, the difference in the lung doses between the AXB_Dm and AXB_Dw plans did not always produce a clear trend, with difference ranged from -1.4% to 2.9%. For both the left and right breast cancer, the AXB_Dm plans produced higher maximum dose to the PTV for all cases. The evaluation of the maximum dose to the skin showed higher values in the AXB_Dm plans for all 5 left breast cancer cases, whereas only 2 cases had higher maximum dose to the skin in the AXB_Dm plans for the right breast cancer

  5. Evaluation of the population dose due to the gaseous emission of a radioisotopes production unit

    International Nuclear Information System (INIS)

    Gordon, A.M.P.L.; Jacomino, V.M.F.; Sordi, G.-M.A.A.

    1990-05-01

    In order to control the emission of gaseous radioactive iodine from the unit responsible for the production of radioisotopes of IPEN-CNEN/SP, a discharge monitoring is carried out. In 1988 an activity of 65 GBq of I-131 was discharged to the environment. Based upon this value and the site analysis, the effective equivalent dose in the general public was evaluated for normal operation and for an incidental discharge. The evaluation was carried out by using a diffusion atmospheric model, 500 to 7000 m away from the discharge point and using 8 different wind direction sectors. The critical group was identified as being the people who lives 3000 m far from the discharge point, in the diffusion sector NW. The dose evaluated at this point is 10 9 times lower than the annual dose limit for individual of the public, according to Radiological Protection Standards. The derived limit for discharge of iodine was also evaluated and it was concluded that the IPEN-CNEN/SP can increase their production up to a level which results in an annual discharge of 1,5 x 10 12 of I-131. (author) [pt

  6. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  7. Comparison of image quality and effective dose by additional filtration on digital chest tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kye Sun [Dept. of Dignostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Sung Chul [Dept. of Radiological Science, Gachon University, Sungnam (Korea, Republic of)

    2015-12-15

    The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

  8. Three-dimensional portal image-based dose reconstruction in a virtual phantom for rapid evaluation of IMRT plans

    International Nuclear Information System (INIS)

    Ansbacher, W.

    2006-01-01

    A new method for rapid evaluation of intensity modulated radiation therapy (IMRT) plans has been developed, using portal images for reconstruction of the dose delivered to a virtual three-dimensional (3D) phantom. This technique can replace an array of less complete but more time-consuming measurements. A reference dose calculation is first created by transferring an IMRT plan to a cylindrical phantom, retaining the treatment gantry angles. The isocenter of the fields is placed on or near the phantom axis. This geometry preserves the relative locations of high and low dose regions and has the required symmetry for the dose reconstruction. An electronic portal image (EPI) is acquired for each field, representing the dose in the midplane of a virtual phantom. The image is convolved with a kernel to correct for the lack of scatter, replicating the effect of the cylindrical phantom surrounding the dose plane. This avoids the need to calculate fluence. Images are calibrated to a reference field that delivers a known dose to the isocenter of this phantom. The 3D dose matrix is reconstructed by attenuation and divergence corrections and summed to create a dose matrix (PI-dose) on the same grid spacing as the reference calculation. Comparison of the two distributions is performed with a gradient-weighted 3D dose difference based on dose and position tolerances. Because of its inherent simplicity, the technique is optimally suited for detecting clinically significant variances from a planned dose distribution, rather than for use in the validation of IMRT algorithms. An analysis of differences between PI-dose and calculation, δ PI , compared to differences between conventional quality assurance (QA) and calculation, δ CQ , was performed retrospectively for 20 clinical IMRT cases. PI-dose differences at the isocenter were in good agreement with ionization chamber differences (mean δ PI =-0.8%, standard deviation σ=1.5%, against δ CQ =0.3%, σ=1.0%, respectively). PI-dose

  9. Effective dose range for dental cone beam computed tomography scanners

    International Nuclear Information System (INIS)

    Pauwels, Ruben; Beinsberger, Jilke; Collaert, Bruno; Theodorakou, Chrysoula; Rogers, Jessica; Walker, Anne; Cockmartin, Lesley; Bosmans, Hilde; Jacobs, Reinhilde; Bogaerts, Ria; Horner, Keith

    2012-01-01

    Objective: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. Materials and methods: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. Results: Effective dose ranged between 19 and 368 μSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. Conclusions: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.

  10. Evaluation of absorbed doses during irradiation of patients

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Kozlov, V.A.

    1981-01-01

    Provided is an analysis of a general scheme for the method of control over the dose field realization in the patient's body using direct dose measurements in patients. On the basis of data from literature presented are error limits in the stages of preradiation preparation and irradiation of patients, and in the stage of dose measurement for different irradiation techniques and radiation types. The authors also provide scientific data of their own. It has been concluded that the main emphasis should be placed on the improvement of topometry facilities, field calculation, patients posture and visual control methods of the radiation beam position [ru

  11. Dose and effect relationship of radiation induced cancer and its influencing factors in experimental animals, 1

    International Nuclear Information System (INIS)

    Sasaki, Shunsaku; Sato, Fumiaki; Eto, Hideo

    1975-01-01

    The data of risk evaluation of external irradiation were integrated with animal experiments from the aspects of qualitative generalizations of characteristics of radiation induced tumors. Studies covered competition of cause of death, figure of dose-to-effect relationship, characteristics of low dose rate of irradiation, relative biological effectiveness (RBE) of high LET radiation, effects of feactionated irradiation, complex actions with chemical substances, effects of protectional medium, differences of radiosensitivity by species and strains, and age dependency of sensitivities. Competition of cause of death by time length of latent period and degree of malignancy of the disease. Discussion on competition of death suggested the following idea: 1) incidence of tumor induction in the individual level did not correspond to transformation in the cellular level, and 2) relative incidence of tumor induction after a certain dose of whole body irradiation did not indicate the relative sensitivity of each tissue, for the relationship between tumor incidence and exposure dose was not a linear relationship. The dose-to-effect relationship of tumor induction was decided by following factors: i) sensitivity on transformation of cells, ii) sensitivity on the death of potential tumor cells, and iii) competition of the cause of death. Tumor induction by low dose rate irradiation was also studied by comparing qualitative and quantitative differences between high dose rate single irradiation and a series of low dose rate irradiation. (Serizawa, K.)

  12. Evaluation of patient absorbed dose in a PET-CT test

    Energy Technology Data Exchange (ETDEWEB)

    Guerra P, F.; Mourao F, A. P. [Federal University of Minas Gerais, Department of Nuclear Engineering, Av. Antonio Carlos 6627, CEP 31270-901, Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P. C., E-mail: fgpaiva92@gmail.com [Federal University of Minas Gerais, Medical School, Av. Prof. Alfredo Balena 190, CEP 30123970, Santa Efigenia, Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    Images of PET-CT has important diagnostic applications, especially in oncology. This equipment allows overlapping of functional images obtained from the administration of radionuclides and anatomical, generated by X-rays. The PET-CT technique may generate higher doses in patients due to the fact that two diagnostic modalities are used in a single examination. A whole body CT scan is performed and in sequence, a capture of the signal generated by the photons emitted is done. In this study, the absorbed and effective doses generated by the CT scan and incorporated by the administration of the radionuclide were evaluated in 19 organs. To evaluate the CT dose, 32 radiochromic film strips were correctly positioned into the anthropomorphic male phantom. The CT protocol performed was whole-body scanning and a high-resolution lung scan. This protocol is currently used in most services. The calculation of the effective dose from the injected activity in the patient was performed using the ICRP 106 Biokinetic model (ICRP 106, 2008). The activity to be injected may vary according to the patients body mass and with the sensitivity of the detector. The mass of the simulator used is 73.5 kg, then the simulation with and injected activity of 244.76 MBq was used. It was observed that 87.4% of the effective dose in examination PET/CT comes from the CT scans, being 63.8% of the whole body scan and 23.6% of high resolution lung scan. Using activity of 0.09 mCi x kg {sup 18}F-FDG radiopharmaceutical contributes only 12.6% of the final effective dose. As a conclusion, it was observed that the dose in patients submitted to the {sup 18}F-FDG PET-CT examination is high, being of great value efforts for its reduction, such as the use of appropriate image acquisition techniques and promoting the application of the principle of optimization of practice. (Author)

  13. Effective dose delivered by conventional radiology to Aosta Valley population between 2002 and 2009

    Science.gov (United States)

    Zenone, F; Aimonetto, S; Catuzzo, P; Peruzzo Cornetto, A; Marchisio, P; Natrella, M; Rosanò, A M; Meloni, T; Pasquino, M; Tofani, S

    2012-01-01

    Objective Medical diagnostic procedures can be considered the main man-made source of ionising radiation exposure for the population. Conventional radiography still represents the largest contribution to examination frequency. The present work evaluates procedure frequency and effective dose from the majority of conventional radiology examinations performed at the Radiological Department of Aosta Hospital from 2002 to 2009. Method Effective dose to the patient was evaluated by means of the software PCXMC. Data provided by the radiological information system allowed us to obtain collective effective and per caput dose. Results The biggest contributors to per caput effective dose from conventional radiology are vertebral column, abdomen, chest, pelvis and (limited to females) breast. Vertebral column, pelvis and breast procedures show a significant dose increment in the period of the study. The mean effective dose per inhabitant from conventional radiology increased from 0.131 mSv in 2002 to 0.156 mSv in 2009. Combining these figures with those from our study of effective dose from CT (0.55 mSv in 2002 to 1.03 mSv in 2009), the total mean effective dose per inhabitant increased from 0.68 mSv to 1.19 mSv. The contribution of CT increased from 81% to 87% of the total. In contrast, conventional radiology accounts for 85% of the total number of procedures, but only 13% of the effective dose. Conclusion The study has demonstrated that conventional radiography still represents the biggest contributor to examination frequency in Aosta Valley in 2009. However, the frequency of the main procedures did not change significantly between 2002 and 2009. PMID:21937611

  14. Multicentre evaluation of a novel vaginal dose reporting method in 153 cervical cancer patients

    DEFF Research Database (Denmark)

    Westerveld, Henrike; de Leeuw, Astrid; Kirchheiner, Kathrin

    2016-01-01

    Background and purpose Recently, a vaginal dose reporting method for combined EBRT and BT in cervical cancer patients was proposed. The current study was to evaluate vaginal doses with this method in a multicentre setting, wherein different applicators, dose rates and protocols were used. Materia...

  15. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  16. An effective dose of ketamine for eliminating pain during injection of propofol: a dose response study.

    Science.gov (United States)

    Wang, M; Wang, Q; Yu, Y Y; Wang, W S

    2013-09-01

    Ketamine can completely eliminate pain associated with propofol injection. However, the effective dose of ketamine to eliminate propofol injection pain has not been determined. The purpose of this study was to determine the effective dose of ketamine needed to eliminate pain in 50% and 95% of patients (ED50 and ED95, respectively) during propofol injections. This study was conducted in a double-blinded fashion and included 50 patients scheduled for elective gynecological laparoscopy under general anesthesia. The initial dose of ketamine used in the first patient was 0.25mg/kg. The dosing modifications were in increments or decrements of 0.025 mg/kg. Ketamine was administered 15 seconds before injecting propofol (2.5mg/kg), which was injected at a rate of 1mL/s. Patients were asked to rate their pain during propofol injection every 5s econds using a 0-3 pain scale. The highest pain score was recorded. The ED50, ED95 and 95% confidence intervals (CI) were determined by probit analyses. The dose of ketamine ranged from 0.175 to 0.275 mg/kg. The ED50 and ED95 of ketamine for eliminating pain during propofol injection were 0.227 mg/kg and 0.283 mg/kg, respectively (95%CI: 0.211-0.243 mg/kg and 0.26-0.364 mg/kg, respectively). Ketamine at an approximate dose of 0.3mg/kg was effective in eliminating pain during propofol injection. Copyright © 2013 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  17. Lateral topography for reducing effective dose in low-dose chest CT.

    Science.gov (United States)

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using la