  1. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  2. Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri.

    Science.gov (United States)

    Bonares, Michael J; Vaisman, Alon; Sharkawy, Abdu

    2016-01-01

    Pseudomonas stutzeri is infrequently isolated from clinical specimens, and if isolated, more likely represents colonization or contamination rather than infection. Despite this, there are dozens of case reports which describe clinically significant P. stutzeri infections at variable sites. A 69-year-old man had a P. stutzeri infection of a prosthetic vascular graft infection, which he received in Panama City. He was successfully treated with a single antipseudomonal agent for 6 weeks and the removal of the infected vascular graft. A 70-year-old man had a P. stutzeri infection of a prosthetic joint, which was successfully treated with a single anti-pseudomonal agent for 6 weeks. There is only one other documented case of a prosthetic vascular graft infection secondary to P. stutzeri . There are 5 documented cases of P. stutzeri prosthetic joint infections. The previous cases were treated with antibiotics and variably, source control with the removal of prosthetic material. Most cases of P. stutzeri infection are due to exposure in health care settings. Immunocompromised states such as HIV or hematological and solid tumor malignancies are risk factors for P. stutzeri infection. Infections caused by P. stutzeri are far less frequent and less fatal than those caused by P. aeruginosa. The etiology of a P. stutzeri infection could be exposure to soil and water, but also contaminated material in the health care setting or an immunocompromised state. Iatrogenic infections that are secondary to health care tourism are a potential cause of fever in the returned traveler.

  3. A 15-Year Comparative Prospective Study of Surgical and Prosthetic Care and Aftercare of Overdenture Treatment in the Atrophied Mandible : Augmentation Versus Nonaugmentation

    NARCIS (Netherlands)

    Visser, Anita; Stellingsma, Cornelis; Raghoebar, Gerry M.; Meijer, Henny J. A.; Vissink, Arjan

    2016-01-01

    BackgroundDifferent treatment strategies for the atrophied mandible are described in literature. The need for long term care and aftercare for these strategies is sparsely described, however. PurposeTo prospectively assess the need for prosthetic and surgical care and aftercare of two implant

  4. DNAAlignEditor: DNA alignment editor tool

    Directory of Open Access Journals (Sweden)

    Guill Katherine E

    2008-03-01

    Full Text Available Abstract Background With advances in DNA re-sequencing methods and Next-Generation parallel sequencing approaches, there has been a large increase in genomic efforts to define and analyze the sequence variability present among individuals within a species. For very polymorphic species such as maize, this has lead to a need for intuitive, user-friendly software that aids the biologist, often with naïve programming capability, in tracking, editing, displaying, and exporting multiple individual sequence alignments. To fill this need we have developed a novel DNA alignment editor. Results We have generated a nucleotide sequence alignment editor (DNAAlignEditor that provides an intuitive, user-friendly interface for manual editing of multiple sequence alignments with functions for input, editing, and output of sequence alignments. The color-coding of nucleotide identity and the display of associated quality score aids in the manual alignment editing process. DNAAlignEditor works as a client/server tool having two main components: a relational database that collects the processed alignments and a user interface connected to database through universal data access connectivity drivers. DNAAlignEditor can be used either as a stand-alone application or as a network application with multiple users concurrently connected. Conclusion We anticipate that this software will be of general interest to biologists and population genetics in editing DNA sequence alignments and analyzing natural sequence variation regardless of species, and will be particularly useful for manual alignment editing of sequences in species with high levels of polymorphism.

  5. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    Science.gov (United States)

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Adaptive sports technology and biomechanics: prosthetics.

    Science.gov (United States)

    De Luigi, Arthur Jason; Cooper, Rory A

    2014-08-01

    With the technologic advances in medicine and an emphasis on maintaining physical fitness, the population of athletes with impairments is growing. It is incumbent upon health care practitioners to make every effort to inform these individuals of growing and diverse opportunities and to encourage safe exercise and athletic participation through counseling and education. Given the opportunities for participation in sports for persons with a limb deficiency, the demand for new, innovative prosthetic designs is challenging the clinical and technical expertise of the physician and prosthetist. When generating a prosthetic prescription, physicians and prosthetists should consider the needs and preferences of the athlete with limb deficiency, as well as the functional demands of the chosen sporting activity. The intent of this article is to provide information regarding the current advancements in the adaptive sports technology and biomechanics in the field of prosthetics, and to assist clinicians and their patients in facilitating participation in sporting activities. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. From satisfaction to expectation: the patient's perspective in lower limb prosthetic care.

    Science.gov (United States)

    Van der Linde, Harmen; Hofstad, Cheriel J; Geertzen, Jan H B; Postema, Klaas; Van Limbeek, Jacques

    2007-07-15

    To obtain information about the wishes and experiences of patients with a lower limb amputation with regard to prosthetic prescription and their exchange of information with the healthcare providers. Cross-sectional questionnaire. Outpatient clinic of a Rehabilitation Centre. A random sample of patients with a lower limb amputation (n = 81). In analogy with the QUOTE questionnaire a focus group technique was used. Prosthetic users formulated 24 specific items, which were of importance according to them. The items were divided into 4 categories: (i) service demand, (ii) prosthetic prescription, (iii) information, (iv) insurance aspects. The questionnaire consisted of two sets (A and B) of 24 items rating importance of items and experience in everyday practice. To identify different dimensions within the 24 items, a factor analysis in SPSS was performed for lists A and B followed by a varimax rotation. Impact factors were calculated by multiplying the mean score of importance on an item with the percentage of patients that experienced this item as negative. A total of 113 questionnaires were sent by e-mail with a response of 73%. The outcomes of the questionnaires resulted in 2 sets of information: One concerning the importance of several items in the process of prosthetic prescription, the other the experience of the prosthetic user about those items. By multiplying the scores on importance by the percentage of negative experience per item (impact score) points of improvement for clinical practice were formulated. A discrepancy between the needs of patients and what they experience in their contacts with clinical professionals as the most important dimension was noticed. A questionnaire with specific items for a homogeneous target group is a good method to formulate points of improvement for clinical practice in healthcare.

  8. Cost analysis of debridement and retention for management of prosthetic joint infection.

    Science.gov (United States)

    Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M

    2013-02-01

    Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  9. An Evaluation of Dental Prosthetic Status and Prosthetic Needs ...

    African Journals Online (AJOL)

    present cross‑sectional study aimed to evaluate the dental prosthetic status and prosthetic needs among eunuchs .... who consented to become part of the study guided us to the .... to the reason that our study population comprised of adults with low SES. ... Arora M, Schwarz E, Sivaneswaran S, Banks E. Cigarette smoking.

  10. From the Editor

    OpenAIRE

    Ugur Demiray

    2011-01-01

    Turkish Online Journal of Distance Education-TOJDE April 2011 ISSN 1302-6488 Volume: 12 Number: 2 from EditorGreetings Dear readers of TOJDE,TOJDE is appeared on your screen now as Volume 12, Number: 2. In this issue it is published 4 notes for Editor, 14 articles, 1 book review. And this time, 43 authors from 10 different countries are placed. These published articles are from Austrlia, Bangldesh, India, lndonasia, Iran, Malaysia. Pakistan, Serbia, Turkey and USA.The first Notes for editor a...

  11. From the Editors

    Directory of Open Access Journals (Sweden)

    Sibel Sakarya Yucel Demiral

    2017-04-01

    Full Text Available Prof. Ray W. Guillery, English Editor of our Journal has passed away… Prof. Guillery (Greifswald-Germany; 1929 is a British physiologist and neuroanatomist. He began his education as a medical student at University College London (UCL. He obtained his BSc and his PhD in Anatomy. Guillery taught at UCL for 11 years. He helped to start the new graduate program in neuroscience in several Universities. In 1989, Guillery was the founding editor-in-chief of the European Journal of Neuroscience. He was Honorary Emeritus Research Fellow at the Anatomical Neuropharmacology Unit at Oxford since 2010.Prof R Guillery joined Turkish Journal of Public Health family with the second issue of 2008 and since then he worked with us for English edition of 24 issues voluntarily;  always in time and with a unique care. He would not only correct English grammar mistakes in manuscripts; but provide significant contribution by indicating unclear points as an interested reader; despite public health was not his area. During time, he developed interest to several public health issues and discussed with us. Ray was not only good in words but numbers; he would detect calculation mistakes in the manuscripts which were missed by reviewers and/or editors. Prof Ray Guillery conducted a course on Scientific Writing in English during National Public Health Congress which was held in Bursa. He has been always keen and generous in sharing his knowledge and experience. He never stopped his works in neuroscience and anatomy and completed his last book a few weeks before passing away.A big loss for scientific world and for our Journal. We express our appreciation for his contribution to our Journal and to all of us. Sibel Sakarya, Yücel Demiral 

  12. OPM Scheme Editor 2: A graphical editor for specifying object-protocol structures

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Min A.; Markowitz, V.M.; Pang, F.; Ben-Shachar, O.

    1993-07-01

    This document describes an X-window based Schema Editor for the Object-Protocol Model (OPM). OPM is a data model that supports the specification of complex object and protocol classes. objects and protocols are qualified in OPM by attributes that are defined over (associated with) value classes. Connections of object and protocol classes are expressed in OPM via attributes. OPM supports the specification (expansion) of protocols in terms of alternative and sequences of component (sub) protocols. The OPM Schema Editor allows specifying, displaying, modifying, and browsing through OPM schemas. The OPM Schema Editor generates an output file that can be used as input to an OPM schema translation tool that maps OPM schemas into definitions for relational database management systems. The OPM Schema Editor was implemented using C++ and the X11 based Motif toolkit, on Sun SPARCstation under Sun Unix OS 4.1. This document consists of the following parts: (1) A tutorial consisting of seven introductory lessons for the OPM Schema Editor. (2) A reference manual describing all the windows and functions of the OPM Schema Editor. (3) An appendix with an overview of OPM.

  13. Examining Editor-Author Ethics: Real-World Scenarios from Interviews with Three Journal Editors

    Science.gov (United States)

    Amare, Nicole; Manning, Alan

    2009-01-01

    Those who submit manuscripts to academic journals may benefit from a better understanding of how editors weigh ethics in their interactions with authors. In an attempt to ascertain and to understand editors' ethics, we interviewed 3 current academic journal editors of technical and/or business communication journals. We asked them about the…

  14. Prosthetic Joint Infection

    Science.gov (United States)

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  15. Fused Filament Fabrication of Prosthetic Components for Trans-Humeral Upper Limb Prosthetics

    Science.gov (United States)

    Lathers, Steven M.

    Presented below is the design and fabrication of prosthetic components consisting of an attachment, tactile sensing, and actuator systems with Fused Filament Fabrication (FFF) technique. The attachment system is a thermoplastic osseointegrated upper limb prosthesis for average adult trans-humeral amputation with mechanical properties greater than upper limb skeletal bone. The prosthetic designed has: a one-step surgical process, large cavities for bone tissue ingrowth, uses a material that has an elastic modulus less than skeletal bone, and can be fabricated on one system. FFF osseointegration screw is an improvement upon the current two-part osseointegrated prosthetics that are composed of a fixture and abutment. The current prosthetic design requires two invasive surgeries for implantation and are made of titanium, which has an elastic modulus greater than bone. An elastic modulus greater than bone causes stress shielding and overtime can cause loosening of the prosthetic. The tactile sensor is a thermoplastic piezo-resistive sensor for daily activities for a prosthetic's feedback system. The tactile sensor is manufactured from a low elastic modulus composite comprising of a compressible thermoplastic elastomer and conductive carbon. Carbon is in graphite form and added in high filler ratios. The printed sensors were compared to sensors that were fabricated in a gravity mold to highlight the difference in FFF sensors to molded sensors. The 3D printed tactile sensor has a thickness and feel similar to human skin, has a simple fabrication technique, can detect forces needed for daily activities, and can be manufactured in to user specific geometries. Lastly, a biomimicking skeletal muscle actuator for prosthetics was developed. The actuator developed is manufactured with Fuse Filament Fabrication using a shape memory polymer composite that has non-linear contractile and passive forces, contractile forces and strains comparable to mammalian skeletal muscle, reaction

  16. Prevention of Prosthetic Dentistry

    Directory of Open Access Journals (Sweden)

    Eremin O.V.

    2011-03-01

    Full Text Available Prevention in prosthetic dentistry is not just a regular oral hygiene and the prevention of caries in the early stages of its development. The initial goal of orthopedic and dental should be the ability to convey to the patient's sense of pros-thetics that proteziruya one saved more. An example is included prosthetic dental arch defects with bridges or single artificial crowns on implants that will prevent movement of teeth and the continuity of the dentition

  17. From Editor

    OpenAIRE

    Ugur DEmiray

    2011-01-01

    Greetings Dear readers of TOJDE,TOJDE is appeared on your screen now as Volume 12, Number: 1. In this issue it is published 4 notes for Editor, 13 articles, 2 book reviews. And this time, 34 authors from 11 different countries are placed. These published articles are from Cayman Islands, Germany, Greece, India, Iran, Malaysia, Pakistan, Turkey, USA and Zimbabwe.The first Notes for editor arrived from USA, written by Kevin YEE and Jace HARGIS. They focused on “SNAPP:Graphing Student Interactio...

  18. From Editor

    OpenAIRE

    Ugur DEMIRAY

    2012-01-01

    Turkish Online Journal of Distance Education-TOJDE July 2012 ISSN 1302-6488 Volume: 13 Number: 3 from EditorDear TOJDE Readers,Welcome to the Volume 13 Number: 3 of TOJDE! In this issue, 2 Notes for Editor and 26 articles of 51 authors from 14 different countries around the world have been published. These published articles are from, Algeria, Australia, Bengaldesh, Greece, India, Iran, Malaysia, Mariutius, Nigeria, Oman, Spain, Turkey, USA and Zimbabwe.First all, you should know that if a su...

  19. From Editor

    OpenAIRE

    Ugur Demiray

    2013-01-01

    Dear TOJDE Readers, Welcome to the Volume 14 Number: 2 of TOJDE! In this issue, 3 Notes for Editor, 2 Book Reviews and 21 articles of 40 authors from 14 different countries around the world have been published. These published articles are arrived to the TOJDE from Argentina, Australia, Bosnia Hersek, Egypt, India, Malaysia, Romania, Saudi Arabia, Tanzania, Thailand, Turkey, United Arab Emirate and USA. The 1st Notes for Editor is arrived from USA and written by Gail D. CARUTH,...

  20. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    Science.gov (United States)

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M

    2012-01-01

    A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.

  1. Becoming an Online Editor: Perceived Roles and Responsibilities of Wikipedia Editors

    Science.gov (United States)

    Littlejohn, Allison; Hood, Nina

    2018-01-01

    Introduction: We report on the experiences of a group of people as they become Wikipedia editors. We test Benkler's (2002) theory that commons-based production processes accelerate the creation of capital, questioning what knowledge production processes do people engage in as they become editors? The analysis positions the development of editing…

  2. A CDL written intercom editor

    International Nuclear Information System (INIS)

    Marinescu, D.S.; Shirikov, V.P.

    1977-01-01

    This report contains the formalized description of the program EDITOR which is the most important part of the teleprocessing system INTERCOM driving terminals for CDC series 6000 and CYBER computers. CDL (Compiler Description language) is used for this description. EDITOR is a tool for the text file acquisition and modifications. It also gives the possibility to execute some commands to the computer software. The EDITOR independent description may be used for the implementation of EDITOR-like programmes for different types of computers (is particular, small computers)

  3. From Editor

    OpenAIRE

    Ugur Demiray

    2012-01-01

    Dear TOJDE Readers,Welcome to the Volume 13 Number: 2 of TOJDE! In this issue, 7 notes for Editor and 22 articles one book review of 57 authors from 12 different countries have been published. These published articles are from, Barbados, Ethiopia, India, Indonesia, Iran, Nigeria, Pakistan, Russia, Saudi Arabia, Turkey, USA and Zimbabwe.In general, around 13 articles and 4 notes for editors have been published in TOJDE so far. I would like to explain, why this time 22 articles and 8 submission...

  4. From Editor

    OpenAIRE

    Ugur Demiray

    2010-01-01

    Greetings Dear readers of TOJDE,TOJDE is appeared on your screen now again after 3 months as Volume 11, Number: 2. This is the second issue of the year 2010. In this issue it is published four Notes for Editor, fourteen articles and four book reviews. And this time, 37 authors from 8 different countries are placed. These published articles are from Greece, Indonesia, Iran, Malaysia, Pakistan, Saudi Arabia, USA and Turkey.Again Kevin YEE & Jace HARGIS have sent a good and short note to editor ...

  5. Prosthetic joint infection: A pluridisciplinary multi-center audit bridging quality of care and outcome.

    Science.gov (United States)

    Roger, P-M; Tabutin, J; Blanc, V; Léotard, S; Brofferio, P; Léculé, F; Redréau, B; Bernard, E

    2015-06-01

    Care to patients with prosthetic joint infections (PJI) is provided after pluridisciplinary collaboration, in particular for complex presentations. Therefore, to carry out an audit in PJI justifies using pluridisciplinary criteria. We report an audit for hip or knee PJI, with emphasis on care homogeneity, length of hospital stay (LOS) and mortality. Fifteen criteria were chosen for quality of care: 5 diagnostic tools, 5 therapeutic aspects, and 5 pluridisciplinary criteria. Among these, 6 were chosen: surgical bacterial samples, surgical strategy, pluridisciplinary discussion, antibiotic treatment, monitoring of antibiotic toxicity, and prevention of thrombosis. They were scored on a scale to 20 points. We included PJI diagnosed between 2010 and 2012 from 6 different hospitals. PJI were defined as complex in case of severe comorbid conditions or multi-drug resistant bacteria, or the need for more than 1 surgery. Eighty-two PJI were included, 70 of which were complex (85%); the median score was 15, with a significant difference among hospitals: from 9 to 17.5 points, P < 0.001. The median LOS was 17 days, and not related to the criterion score; 16% of the patients required intensive care and 13% died. The cure rate was 41%, lost to follow-up 33%, and therapeutic failure 13%. Cure was associated with a higher score than an unfavorable outcome in the univariate analysis (median [range]): 16 [9-18] vs 13 [4-18], P = 0.002. Care to patients with PJI was heterogeneous, our quality criteria being correlated to the outcome. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. ISTP CDF Skeleton Editor

    Science.gov (United States)

    Chimiak, Reine; Harris, Bernard; Williams, Phillip

    2013-01-01

    Basic Common Data Format (CDF) tools (e.g., cdfedit) provide no specific support for creating International Solar-Terrestrial Physics/Space Physics Data Facility (ISTP/SPDF) standard files. While it is possible for someone who is familiar with the ISTP/SPDF metadata guidelines to create compliant files using just the basic tools, the process is error-prone and unreasonable for someone without ISTP/SPDF expertise. The key problem is the lack of a tool with specific support for creating files that comply with the ISTP/SPDF guidelines. There are basic CDF tools such as cdfedit and skeletoncdf for creating CDF files, but these have no specific support for creating ISTP/ SPDF compliant files. The SPDF ISTP CDF skeleton editor is a cross-platform, Java-based GUI editor program that allows someone with only a basic understanding of the ISTP/SPDF guidelines to easily create compliant files. The editor is a simple graphical user interface (GUI) application for creating and editing ISTP/SPDF guideline-compliant skeleton CDF files. The SPDF ISTP CDF skeleton editor consists of the following components: A swing-based Java GUI program, JavaHelp-based manual/ tutorial, Image/Icon files, and HTML Web page for distribution. The editor is available as a traditional Java desktop application as well as a Java Network Launching Protocol (JNLP) application. Once started, it functions like a typical Java GUI file editor application for creating/editing application-unique files.

  7. The influence of environmental and personal factors on participation of lower-limb prosthetic users in low-income countries: prosthetists' perspectives.

    Science.gov (United States)

    Kam, Season; Kent, Mallory; Khodaverdian, Alin; Daiter, Liane; Njelesani, Janet; Cameron, Debra; Andrysek, Jan

    2015-05-01

    To examine the environmental and personal factors in low-income countries (LICs) that influence prosthetic rehabilitation of adults with lower-limb (LL) amputations and their ability to participate in daily activities. In this qualitative descriptive study, 11 prosthetists participated in semi-structured interviews by telephone or Skype. Qualitative thematic analysis was guided by the International Classification of Function. Facilitating continuity of care, consideration of physical environments and usage, prosthetic quality including durability and socket fit, and minimizing the visibility of disability, were found to be important factors affecting the provision of prosthetic services in LICs. Environmental and personal factors must be considered when providing prosthetic rehabilitation for adults with LL amputations in LICs in order to optimize participation in activities. Results from this study provide new insights about some of the factors that influence the ability of individuals with LL amputations to rehabilitate to a level where they are able to participate in meaningful activities within their communities. There are unique environmental and personal components that can influence activity and participation of lower-limb (LL) prosthetic users in low-income countries (LICs). These components are often overlooked in the design of prosthetic devices and provision of prosthetic services. Continuity of care, condition of the post-surgical residuum, outdoor environments of common occupations, aesthetics and durability of prostheses, and user comfort should all be considered when providing prosthetic rehabilitation to adults with LL amputations in LICs to promote activity and participation. Results of our study can inform the practice of prosthetists in LICs by highlighting their contributions in enabling participation for LL prosthetic users. Our results can also inform the design of durable and comfortable prostheses and the provision of more appropriate

  8. Good editorial practice: editors as educators.

    Science.gov (United States)

    Marusić, M; Marusić, A

    2001-04-01

    There may be valuable research going on in the developing and financially less-privileged countries, but it usually does not reach international visibility, in spite of a large number of scientific journals in these countries. Such journals are not only invisible but, by perpetuating a vicious circle of inadequacy, may be directly damaging to the local science and research culture. We call for an international action to help journal editors in less privileged countries. International associations of editors may be leaders of these activities by defining, promoting, and perhaps controlling good editorial practice, as a main criterion for international recognition of a journal. However, the editors of small journals have the power and moral obligation to become a stronghold of quality and advancement in their scientific community. Their educational "tools" are editorial integrity and author-friendly policy. Editors can teach the authors study design, statistical analysis, precision, punctuality, research integrity, style and format of writing, and other aspects of scientific communication. The editors of "big", mainstream scientific journals can act as global educators, teaching and providing guidance to editors of small journals. The editors from developed countries as leaders, and editors from less advantageous environments as teachers are the key figures in shaping research communication in less privileged scientific communities.

  9. The effects of common footwear on stance-phase mechanical properties of the prosthetic foot-shoe system.

    Science.gov (United States)

    Major, Matthew J; Scham, Joel; Orendurff, Michael

    2018-04-01

    Prosthetic feet are prescribed based on their mechanical function and user functional level. Subtle changes to the stiffness and hysteresis of heel, midfoot, and forefoot regions can influence the dynamics and economy of gait in prosthesis users. However, the user's choice of shoes may alter the prosthetic foot-shoe system mechanical characteristics, compromising carefully prescribed and rigorously engineered performance of feet. Observe the effects of footwear on the mechanical properties of the prosthetic foot-shoe system including commonly prescribed prosthetic feet. Repeated-measures, Mechanical characterization. The stiffness and energy return was measured using a hydraulic-driven materials test machine across combinations of five prosthetic feet and four common shoes as well as a barefoot condition. Heel energy return decreased by an average 4%-9% across feet in all shoes compared to barefoot, with a cushioned trainer displaying the greatest effect. Foot designs that may improve perceived stability by providing low heel stiffness and rapid foot-flat were compromised by the addition of shoes. Shoes altered prosthesis mechanical characteristics in the sagittal and frontal planes, suggesting that shoe type should be controlled or reported in research comparing prostheses. Understanding of how different shoes could alter certain gait-related characteristics of prostheses may aid decisions on footwear made by clinicians and prosthesis users. Clinical relevance Shoes can alter function of the prosthetic foot-shoe system in unexpected and sometimes undesirable ways, often causing similar behavior across setups despite differences in foot design, and prescribing clinicians should carefully consider these effects on prosthesis performance.

  10. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  11. From satisfaction to expectation: the patient's perspective in lower limb prosthetic care.

    NARCIS (Netherlands)

    Linde, H. van der; Hofstad, C.J.; Geertzen, J.H.; Postema, K.; Limbeek, J. van

    2007-01-01

    PURPOSE: To obtain information about the wishes and experiences of patients with a lower limb amputation with regard to prosthetic prescription and their exchange of information with the healthcare providers. METHOD: Design: Cross-sectional questionnaire. Setting: Outpatient clinic of a

  12. From satisfaction to expectation : The patient's perspective in lower limb prosthetic care

    NARCIS (Netherlands)

    Van der Linde, Harmen; Hofstad, Cheriel J.; Geertzen, Jan H. B.; Postema, Klaas; Van Limbeek, Jacques

    2007-01-01

    Purpose. To obtain information about the wishes and experiences of patients with a lower limb amputation with regard to prosthetic prescription and their exchange of information with the healthcare providers. Method. Design: Cross-sectional questionnaire. Setting: Outpatient clinic of a

  13. Prosthetic Joint Infections

    Science.gov (United States)

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  14. Editor de la revista: entre el sueño y la supervivencia

    Directory of Open Access Journals (Sweden)

    Targino, María das Graças

    2010-01-01

    and the dilemmas inherent in the function of generating the intellectual production (of any kind; the increasing commercializing of the intellectual and scientific like commercial products; the multiplicity of functions imposed to the editor in his daily life; and the question of quantity versus quality of originals sent to scientific journals. Finally, it highlights the importance of the scientific journal editor, who guarantees safety, quality and recognition of the titles published and, therefore, of the scientific communication through careful with the quality of scientific work.

  15. A qualitative study of the challenges of providing pre-prosthetic rehabilitation in rural South Africa.

    Science.gov (United States)

    Ennion, Liezel; Johannesson, Anton

    2018-04-01

    There is a known shortage of rehabilitation staff in rural settings and a sharp increase in the number of lower limb amputations being performed. A lack of adequate pre-prosthetic rehabilitation will result in worse physical and psychological outcomes for a person with a lower limb amputation, and they will not be eligible to be fitted with a prosthesis. To explore therapists' experiences with providing pre-prosthetic rehabilitation in a rural setting. A qualitative descriptive approach was used to collect and analyse data. Data were collected from 17 purposively sampled therapists in five district hospitals in a rural community in South Africa. Data were collected in two rounds of focus groups to explore the challenges of providing pre-prosthetic rehabilitation in rural South Africa. The main themes identified in the study were (1) a lack of government health system support, (2) poor socioeconomic circumstances of patients and (3) cultural factors that influence rehabilitation. These themes all negatively influence the therapists' ability to follow up patients for pre-prosthetic rehabilitation after discharge from hospital. A lack of adequate pre-prosthetic rehabilitation is a substantial barrier to prosthetic fitting in rural South Africa. Patients who do not receive pre-prosthetic rehabilitation have a poorly shaped residuum or other complications such as knee or hip joint contractures which disqualifies them from being referred to prosthetic services. Therapists involved in this study identified the most important barriers to patients having access to prosthetic services. Clinical relevance Pre-prosthetic rehabilitation provides care of the residuum; maintenance or improvement of physical strength, joint range of motion and referral to a prosthetist. By exploring the challenges known to exist in this service, we can identify potential ways to reduce these barriers and improve the lives of those who use it.

  16. Isolated Lactobacillus chronic prosthetic knee infection.

    Science.gov (United States)

    Bennett, David M; Shekhel, Tatyana; Radelet, Matt; Miller, Michael D

    2014-01-01

    Lactobacillus is a gram-positive rod bacteria found primarily in the gastrointestinal and female genital tracts. Prosthetic infections in implants are being increasingly reported. The authors present a case of a 58-year-old patient with Lactobacillus septic prosthetic knee joint infection. To the authors’ knowledge, this is the first reported case of chronic prosthetic knee infection with isolated Lactobacillus species. Lactobacillus has been most commonly implicated with bacteremia and endocarditis and rarely with pneumonia, meningitis, and endovascular infection, and a vast majority of the cases are reported in immunocompromised patients. In the current case, diabetes mellitus, hepatitis, malnutrition, anemia, and liver failure were comorbid conditions, placing the patient at increased risk of infection. The findings suggest that further case series are necessary to establish the significance of Lactobacillus as an etiologic agent in chronic low-virulence, and potentially vancomycin-resistant, prosthetic joint infection. The need also exists for further research aimed at the risk of prosthetic joint infection with oral intake of certain probiotic foods and supplements. The goal of this case report is to bring to light the potential of this organism to be a cause of subtle chronic prosthetic joint infection.

  17. From the Editor

    OpenAIRE

    Ugur Demiray

    2009-01-01

    Greetings Dear readers of TOJDE,TOJDE is appeared on your screen now as Volume 10, Number: 2. This is the second issue of the year 2009 and 10th anniversary of TOJDE. In this issue it is published four notes for Editor, 13 articles, 2 reviews. And this time, 28 authors from 8 different countries are placed. These published articles are from Canada, Gana, India, Iran, Malaysia, Pakistan, United Kingdom and Turkey. “Reflective Approach In Teaching Pre-Degree Chemistry” has sent to editor of TOJ...

  18. From the Editor

    OpenAIRE

    Ugur Demiray

    2011-01-01

    Dear readers of TOJDE,TOJDE appears on your screen now as Volume 12, Number: 4. In this issue it publishes 5 notes for Editor, 10 articles, 2 book reviews. And this time, 33 authors from 10 different countries are placed. These published articles are from Bangladesh, Ethiopia, India, Malaysia, Nigeria, Pakistan, Saudi Arabia, Turkey, UAE and USA. The first Notes for editor arrived from USA, written by Kevin YEE and Jace HARGIS. They focused on Google+ is like Twitter in that anyone can follo...

  19. From the Editor

    OpenAIRE

    Ugur Demiray

    2012-01-01

    Greetings Dear readers of TOJDE,TOJDE is appeared on your screen now as Volume 13 Number: 1 In this issue it is published 5 notes for Editor, 16articles, 2 books reviews a nd this time, 53 authors from 12 different countries are placed. These published articles are from Azerbaijan, Bangladesh, Greece, Iran, Malaysia, Morocco, Nigeria, Pakistan, Turkey, UAE and USA.The first Notes for editor arrived from USA, written by Kevin YEE and Jace HARGIS. They focused on Simply including a narrative co...

  20. Computer Aided Facial Prosthetics Manufacturing System

    Directory of Open Access Journals (Sweden)

    Peng H.K.

    2016-01-01

    Full Text Available Facial deformities can impose burden to the patient. There are many solutions for facial deformities such as plastic surgery and facial prosthetics. However, current fabrication method of facial prosthetics is high-cost and time consuming. This study aimed to identify a new method to construct a customized facial prosthetic. A 3D scanner, computer software and 3D printer were used in this study. Results showed that the new developed method can be used to produce a customized facial prosthetics. The advantages of the developed method over the conventional process are low cost, reduce waste of material and pollution in order to meet the green concept.

  1. Anaerobic prosthetic joint infection.

    Science.gov (United States)

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  2. EDITORIAL: Message from the Editor Message from the Editor

    Science.gov (United States)

    Thomas, Paul

    2010-02-01

    November 2009 and provided particularly detailed advice to the authors. The other three have been very helpful in 'minority fields'. We have excluded our Board members, Guest Editors of special editions and those referees who were already listed in the last four years. Guest Editors' work on papers submitted to their Special Issues is also excluded from consideration. The following people have been selected: Tomonori Takizuka, JAEA-Naka Fusion Institute, Japan Rudolf Neu, Max-Planck-Institut für Plasmaphysik, Germany Sibylle Guenter, Max-Planck-Institut für Plasmaphysik, Germany Taik-Soo Hahm, Princeton Plasma Physics Laboratory, United States David R. Mikkelsen, Princeton Plasma Physics Laboratory, United States Peter C. de Vries, EURATOM/UKAEA Fusion Association, United Kingdom Yasuhiro Suzuki, National Institute for Fusion Science, Japan Jerzy Wolowski, Institute of Plasma Physics and Laser Microfusion, Poland Tetsuo Tanabe, Kyushu University, Japan Yasuyuki Yagi, National Institute of Advanced Industrial Science and Technology, Japan Congratulations and many, many thanks! The Guest Editors of special editions deserve a special mention for the excellent help that they have given us. They are: Taik-Soo Hahm, Princeton Plasma Physics Laboratory, United States, Special Issue on H-Mode Physics and Transport Barriers Yaroslav Kolesnichenko, Institute for Nuclear Research, Ukraine, Special Issue on Energetic Particles in Magnetic Confinement Systems Kimitaka Itoh, National Institute for Fusion Science, Japan and Howard R. Wilson, University of York, UK, Special Issue on Plasma Instabilities Bernhard Unterberg, Forschungszentrum Juelich, Germany, Special Issue on Stochastic Fusion Plasma In addition, there is a group of several hundred referees who have helped us in the past year to maintain the high scientific standard of Nuclear Fusion. At the end of this issue we give the full list of all referees for 2009. Our thanks to them! Authors The winner of the 2009 Nuclear Fusion

  3. New Editors Appointed for Water Resources Research

    Science.gov (United States)

    2009-03-01

    Praveen Kumar (University of Illinois at Urbana-Champaign), the newly appointed editor in chief of Water Resources Research (WRR), heads the new team of editors for the journal. The other editors are Tom Torgersen (University of Connecticut, Groton), who continues his editorship; Tissa Illangasekare (Colorado School of Mines, Golden); Graham Sander (Loughborough University, Loughborough, UK); and John Selker (Oregon State University, Corvallis). Hoshin Gupta (University of Arizona, Tucson) will join WRR at the end of 2009. The new editors will begin receiving submissions immediately. The incoming editorial board thanks outgoing editors Marc Parlange, Brian Berkowitz, Amilcare Porporato, and Scott Tyler, all of whom will assist during the transition.

  4. Learning the vi and Vim Editor

    CERN Document Server

    Robbins, Arnold; Hannah, Elbert

    2008-01-01

    There's nothing that hard-core Unix and Linux users are more fanatical about than their text editor. Editors are the subject of adoration and worship, or of scorn and ridicule, depending upon whether the topic of discussion is your editor or someone else's. vi has been the standard editor for close to 30 years. Popular on Unix and Linux, it has a growing following on Windows systems, too. Most experienced system administrators cite vi as their tool of choice. And since 1986, this book has been the guide for vi. However, Unix systems are not what they were 30 years ago, and neither is this

  5. Personalized management of hyperglycemia in type 2 diabetes: reflections from a Diabetes Care Editors' Expert Forum.

    Science.gov (United States)

    Raz, Itamar; Riddle, Matthew C; Rosenstock, Julio; Buse, John B; Inzucchi, Silvio E; Home, Philip D; Del Prato, Stefano; Ferrannini, Ele; Chan, Juliana C N; Leiter, Lawrence A; Leroith, Derek; Defronzo, Ralph; Cefalu, William T

    2013-06-01

    In June 2012, 13 thought leaders convened in a Diabetes Care Editors' Expert Forum to discuss the concept of personalized medicine in the wake of a recently published American Diabetes Association/European Association for the Study of Diabetes position statement calling for a patient-centered approach to hyperglycemia management in type 2 diabetes. This article, an outgrowth of that forum, offers a clinical translation of the underlying issues that need to be considered for effectively personalizing diabetes care. The medical management of type 2 diabetes has become increasingly complex, and its complications remain a great burden to individual patients and the larger society. The burgeoning armamentarium of pharmacological agents for hyperglycemia management should aid clinicians in providing early treatment to delay or prevent these complications. However, trial evidence is limited for the optimal use of these agents, especially in dual or triple combinations. In the distant future, genotyping and testing for metabolomic markers may help us to better phenotype patients and predict their responses to antihyperglycemic drugs. For now, a personalized ("n of 1") approach in which drugs are tested in a trial-and-error manner in each patient may be the most practical strategy for achieving therapeutic targets. Patient-centered care and standardized algorithmic management are conflicting approaches, but they can be made more compatible by recognizing instances in which personalized A1C targets are warranted and clinical circumstances that may call for comanagement by primary care and specialty clinicians.

  6. The role of osteoblasts in peri-prosthetic osteolysis.

    LENUS (Irish Health Repository)

    O'Neill, S C

    2013-08-01

    Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis. In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

  7. Overview: Mechanism and Control of a Prosthetic Arm.

    Science.gov (United States)

    Kulkarni, Tushar; Uddanwadiker, Rashmi

    2015-09-01

    Continuous growth in industrialization and lack of awareness in safety parameters the cases of amputations are growing. The search of safer, simpler and automated prosthetic arms for managing upper limbs is expected. Continuous efforts have been made to design and develop prosthetic arms ranging from simple harness actuated to automated mechanisms with various control options. However due the cost constraints, the automated prosthetic arms are still out of the reach of needy people. Recent data have shown that there is a wide scope to develop a low cost and light weight upper limb prosthesis. This review summarizes the various designs methodologies, mechanisms and control system developed by the researchers and the advances therein. Educating the patient to develop acceptability to prosthesis and using the same for the most basic desired functions of human hand, post amputation care and to improve patient's independent life is equally important. In conclusion it can be interpreted that there is a wide scope in design in an adaptive mechanism for opening and closing of the fingers using other methods of path and position synthesis. Simple mechanisms and less parts may optimize the cost factor. Reduction in the weight of the prosthesis may be achieved using polymers used for engineering applications. Control system will remain never ending challenge for the researchers, but it is essential to maintain the simplicity from the patients perspective.

  8. EDITORIAL: Incoming Editor-in-Chief Incoming Editor-in-Chief

    Science.gov (United States)

    Birch, David

    2012-01-01

    It is a pleasure and an honour for me to be taking over as Editor-in-Chief of Measurement Science and Technology. MST is well known across research communities worldwide as a leading journal in which to publish new techniques and instrumentation. It has gained this enviable position largely because of the excellent guidance of its Editorial Board and dedicated staff at Institute of Physics Publishing over many years. I want to highlight in particular the contribution of the outgoing Editor Peter Hauptmann, and other Editors before him, in making the journal truly international. We thank Peter immensely for all his hard work in leading the journal, having exceptionally served two terms, each of five years. I come into the post of Editor at a very interesting and challenging time for research. The global recession is leading to cuts in research funding in many countries, researchers and their outputs are coming under closer scrutiny than ever before, and more is being expected of them. Journals play a critical role in monitoring and maintaining research standards, but we should be careful not to assume that journal Impact Factor is the sole measure of research quality. Although expediency may sometimes demand it, Impact Factor, as practitioners know, is subject dependent. One of the great things about science and technology for me is its level playing field. The key point is still innovation no matter where the work is done or where it is published. MST has a long pedigree of being the natural home of the highest quality papers from leading researchers wishing to report novel instrumentation and techniques. 2013 will mark the 90th anniversary of MST and we look forward to celebrating in style its sustained success. I recall with pride the first paper I published in Journal of Physics E: Scientific Instruments (as MST was previously titled) back in 1977. The paper reported the design and application of an early fluorescence lifetime spectrometer that I had constructed

  9. Pre-prosthetic surgery: Mandible

    Directory of Open Access Journals (Sweden)

    Veeramalai Naidu Devaki

    2012-01-01

    Full Text Available Pre-prosthetic surgery is that part of oral and maxillofacial surgery which restores oral function and facial form. This is concerned with surgical modification of the alveolar process and its surrounding structures to enable the fabrication of a well-fitting, comfortable, and esthetic dental prosthesis. The ultimate goal of pre-prosthetic surgery is to prepare a mouth to receive a dental prosthesis by redesigning and smoothening bony edges.

  10. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  11. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    Science.gov (United States)

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    of dislocation or a chronically unstable hip prosthesis. Careful technique is required to reduce or retard the risk of intra-prosthetic dislocation. Intra-prosthetic dislocation of a dual mobility socket is an exceptional complication at mid-term. Surgical treatment is required but may be limited to simple insert replacement. Systematic use of this type of implant in young subjects must be carefully examined, but for us, the risk of dislocation does not outweigh the advantages of this original concept of dual mobility. This type of socket remains an useful preventive technique for high-risk hips or for curative treatment of recurrent dislocation.

  12. Prosthetic status and prosthetic need among the patients attending various dental institutes of ahmedabad and gandhinagar district, gujarat.

    Science.gov (United States)

    Shah, Vrinda R; Shah, Darshana N; Parmar, Chaitanya H

    2012-09-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment form (1997). Prosthetic status and prosthetic treatment need was recorded. Out of 510, any type of Edentulousness was 322 (63 %). Among them, 254 (49.8 %) were partially edentulous while 68 (13.3 %) were completely edentulous. Only 69 (13 %) were having any prosthesis in upper arch while only 80 (16 %) were having any prosthesis in lower arch. Need for any type of prosthesis in upper and lower arch was 55 and 60 % in males and females, respectively. In lower social class group need of prosthesis in upper and lower arch was 62 and 63 %, respectively. It was found that prosthetic status and prosthetic treatment need increased with increase in age. Steps should be taken to overcome this disparity and more emphasis should be given to meet the felt need of the people through government and non government organizations to improve the oral health. The unmet prosthetic treatment need should be met to rehabilitate needy people so that their disability may be limited.

  13. Increased risk of prosthetic joint infection associated with esophago-gastro-duodenoscopy with biopsy.

    Science.gov (United States)

    Coelho-Prabhu, Nayantara; Oxentenko, Amy S; Osmon, Douglas R; Baron, Todd H; Hanssen, Arlen D; Wilson, Walter R; Steckelberg, James M; Baddour, Larry M; Harmsen, William S; Mandrekar, Jay; Berbari, Elie F

    2013-02-01

    There are no prospective data regarding the risk of prosthetic joint infection following routine gastrointestinal endoscopic procedures. We wanted to determine the risk of prosthetic hip or knee infection following gastrointestinal endoscopic procedures in patients with joint arthroplasty. We conducted a prospective, single-center, case-control study at a single, tertiary-care referral center. Cases were defined as adult patients hospitalized for prosthetic joint infection of the hip or knee between December 1, 2001 and May 31, 2006. Controls were adult patients with hip or knee arthroplasties but without a diagnosis of joint infection, hospitalized during the same time period at the same orthopedic hospital. The main outcome measure was the odds ratio (OR) of prosthetic joint infection after gastrointestinal endoscopic procedures performed within 2 years before admission. 339 cases and 339 controls were included in the study. Of these, 70 cases (21%) cases and 82 controls (24%) had undergone a gastrointestinal endoscopic procedure in the preceding 2 years. Among gastrointestinal procedures that were assessed, esophago-gastro-duodenoscopy (EGD) with biopsy was associated with an increased risk of prosthetic joint infection (OR = 3, 95% CI: 1.1-7). In a multivariable analysis adjusting for sex, age, joint age, immunosuppression, BMI, presence of wound drain, prior arthroplasty, malignancy, ASA score, and prothrombin time, the OR for infection after EGD with biopsy was 4 (95% CI: 1.5-10). EGD with biopsy was associated with an increased risk of prosthetic joint infection in patients with hip or knee arthroplasties. This association will need to be confirmed in other epidemiological studies and adequately powered prospective clinical trials prior to recommending antibiotic prophylaxis in these patients.

  14. Multi-Disciplinary Antimicrobial Strategies for Improving Orthopaedic Implants to Prevent Prosthetic Joint Infections in Hip and Knee

    Science.gov (United States)

    Getzlaf, Matthew A.; Lewallen, Eric A.; Kremers, Hilal M.; Jones, Dakota L.; Bonin, Carolina A.; Dudakovic, Amel; Thaler, Roman; Cohen, Robert C.; Lewallen, David G.; van Wijnen, Andre J.

    2016-01-01

    Like any foreign object, orthopaedic implants are susceptible to infection when introduced into the human body. Without additional preventative measures, the absolute number of annual prosthetic joint infections will continue to rise, and may exceed the capacity of health care systems in the near future. Bacteria are difficult to eradicate from synovial joints due to their exceptionally diverse taxonomy, complex mechanistic attachment capabilities, and tendency to evolve antibiotic resistance. When a primary orthopaedic implant fails from prosthetic joint infection, surgeons are generally challenged by limited options for intervention. In this review, we highlight the etiology and taxonomic groupings of bacteria known to cause prosthetic joint infections, and examine their key mechanisms of attachment. We propose that antimicrobial strategies should focus on the most harmful bacteria taxa within the context of occurrence, taxonomic diversity, adhesion mechanisms, and implant design. Patient-specific identification of organisms that cause prosthetic joint infections will permit assessment of their biological vulnerabilities. The latter can be targeted using a range of antimicrobial techniques that exploit different colonization mechanisms including implant surface attachment, biofilm formation, and/or hematogenous recruitment. We anticipate that customized strategies for each patient, joint, and prosthetic component will be most effective at reducing prosthetic joint infections, including those caused by antibiotic-resistant and polymicrobial bacteria. PMID:26449208

  15. Prevention of Infection in Orthopedic Prosthetic Surgery.

    Science.gov (United States)

    Chirca, Ioana; Marculescu, Camelia

    2017-06-01

    Total joint arthroplasty is a generally safe orthopedic procedure; however, infection is a potentially devastating complication. Multiple risk factors have been identified for development of prosthetic joint infections. Identification of patients at risk and preoperative correction of known risk factors, such as smoking, diabetes mellitus, anemia, malnutrition, and decolonization of Staphylococcus carriers, represent well-established actions to decrease the infection risk. Careful operative technique, proper draping and skin preparation, and appropriate selection and dosing of antimicrobials for perioperative prophylaxis are also very important in prevention of infection. Published by Elsevier Inc.

  16. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  17. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    Science.gov (United States)

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  18. Letter from the New Editor-in-Chief

    Directory of Open Access Journals (Sweden)

    Pabulo Henrique Rampelotto

    2014-01-01

    Full Text Available It is my great pleasure to serve as the new Editor-in-Chief of Life, a journal concerned with fundamental questions on the origins and nature of life, evolution of biosystems and astrobiology. With my experience as Executive Editor, Senior Editor and Guest Editor of so many successful special issues (some of them in MDPI journals [1–6], I am committed to making the journal a success, with the launch of exciting special issues, publication of high quality papers, as well as inclusion of the journal in major indexing and abstracting services. In this editorial, I present my view and plans for the journal.

  19. A new record editor for Invenio 3

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    On this presentation, a new record editor will be presented. Current version under development can be found in https://github.com/inveniosoftware-contrib/ng2-json-editor. This editor uses JSON as its native data format, provides many configuration options and can handle very large JSON documents. An update on the development status and pointers to how to use it in your own installation will be provided.

  20. A Microsoft Windows version of the MCNP visual editor

    International Nuclear Information System (INIS)

    Schwarz, R.A.; Carter, L.L.; Pfohl, J.

    1999-01-01

    Work has started on a Microsoft Windows version of the MCNP visual editor. The MCNP visual editor provides a graphical user interface for displaying and creating MCNP geometries. The visual editor is currently available from the Radiation Safety Information Computational Center (RSICC) and the Nuclear Energy Agency (NEA) as software package PSR-358. It currently runs on the major UNIX platforms (IBM, SGI, HP, SUN) and Linux. Work has started on converting the visual editor to work in a Microsoft Windows environment. This initial work focuses on converting the display capabilities of the visual editor; the geometry creation capability of the visual editor may be included in future upgrades

  1. Proxima: a presentation-oriented editor for structured documents

    NARCIS (Netherlands)

    Schrage, M.M.

    2004-01-01

    A typical computer user deals with a large variety of documents, such as text files, spreadsheets, and web pages. The applications for constructing and modifying these documents are called editors (e.g. text editors, spreadsheet applications, and HTML editors). Despite the apparent differences

  2. Proxima: a presentation-oriented editor for structured documents

    OpenAIRE

    Schrage, M.M.

    2004-01-01

    A typical computer user deals with a large variety of documents, such as text files, spreadsheets, and web pages. The applications for constructing and modifying these documents are called editors (e.g. text editors, spreadsheet applications, and HTML editors). Despite the apparent differences between editors, the core editing behavior, whether performed in a word-processor or a spreadsheet, is largely similar: document fragments may be copied and pasted, and new parts of the document may be ...

  3. JSME: a free molecule editor in JavaScript.

    Science.gov (United States)

    Bienfait, Bruno; Ertl, Peter

    2013-01-01

    A molecule editor, i.e. a program facilitating graphical input and interactive editing of molecules, is an indispensable part of every cheminformatics or molecular processing system. Today, when a web browser has become the universal scientific user interface, a tool to edit molecules directly within the web browser is essential. One of the most popular tools for molecular structure input on the web is the JME applet. Since its release nearly 15 years ago, however the web environment has changed and Java applets are facing increasing implementation hurdles due to their maintenance and support requirements, as well as security issues. This prompted us to update the JME editor and port it to a modern Internet programming language - JavaScript. The actual molecule editing Java code of the JME editor was translated into JavaScript with help of the Google Web Toolkit compiler and a custom library that emulates a subset of the GUI features of the Java runtime environment. In this process, the editor was enhanced by additional functionalities including a substituent menu, copy/paste, drag and drop and undo/redo capabilities and an integrated help. In addition to desktop computers, the editor supports molecule editing on touch devices, including iPhone, iPad and Android phones and tablets. In analogy to JME the new editor is named JSME. This new molecule editor is compact, easy to use and easy to incorporate into web pages. A free molecule editor written in JavaScript was developed and is released under the terms of permissive BSD license. The editor is compatible with JME, has practically the same user interface as well as the web application programming interface. The JSME editor is available for download from the project web page http://peter-ertl.com/jsme/

  4. Optimising the prescription of prosthetic technologies (opptec): Outcome measures for evidence based prosthetic practice and use

    LENUS (Irish Health Repository)

    Ryall, Dr Nicola

    2010-01-01

    This study provided a forum for patients and service providers to voice their opinions in what they believe to be the important predictors and outcomes involved in successful rehabilitation following limb loss. To develop a consensus on the most important outcomes and factors to address for both the lower limb and upper limb prosthetic prescription process, the above data relating to lower limb and upper prosthetics were subsequently used in the next phase of the research involving two Delphi surveys of 23 and 53 experts within the lower limb and upper limb amputation and prosthetic field respectively, including users, service providers and researchers.\\r\

  5. Vascular complications of prosthetic inter-vertebral discs

    OpenAIRE

    Daly, Kevin J.; Ross, E. Raymond S.; Norris, Heather; McCollum, Charles N.

    2006-01-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had e...

  6. Advanced Prosthetic Gait Training Tool

    Science.gov (United States)

    2015-12-01

    modules to train individuals to distinguish gait deviations (trunk motion and lower-limb motion). Each of these modules help trainers improve their...AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool PRINCIPAL INVESTIGATOR: Dr. Karim Abdel-Malek CONTRACTING...study is to produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities

  7. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    Science.gov (United States)

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (Ppannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    Science.gov (United States)

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  9. Psychometric evaluation of self-report outcome measures for prosthetic applications

    OpenAIRE

    Hafner, Brian J.; Morgan, Sara J.; Askew, Robert L.; Salem, Rana

    2016-01-01

    Documentation of clinical outcomes is increasingly expected in delivery of prosthetic services and devices. However, many outcome measures suitable for use in clinical care and research have not been psychometrically tested with prosthesis users. The aim of this study was to determine test-retest reliability, mode-of-administration (MoA) equivalence, standard error of measurement (SEM), and minimal detectable change (MDC) of standardized, self-report instruments that assess constructs of impo...

  10. Web-Based Media Contents Editor for UCC Websites

    Science.gov (United States)

    Kim, Seoksoo

    The purpose of this research is to "design web-based media contents editor for establishing UCC(User Created Contents)-based websites." The web-based editor features user-oriented interfaces and increased convenience, significantly different from previous off-line editors. It allows users to edit media contents online and can be effectively used for online promotion activities of enterprises and organizations. In addition to development of the editor, the research aims to support the entry of enterprises and public agencies to the online market by combining the technology with various UCC items.

  11. Prosthetic Engineering

    Science.gov (United States)

    ... the household and community environments may lead to falls and injuries. This research aims to develop an ankle that can invert and evert and thereby control the center of pressure under the prosthetic foot; enhancing balance and stability of lower limb amputees. Foot-Ankle ...

  12. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    Science.gov (United States)

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  13. From the Editor

    Directory of Open Access Journals (Sweden)

    Ugur Demiray

    2004-04-01

    Full Text Available Turkish Online Journal of Distance Education-TOJDE April 2004 ISSN 1302-6488 Volume:5 Number:2 -------------------------------------------------------------------------------- From the Editor I am pleased to inform you that Vol.:5, Number:2 issue of The Turkish Online Journal of Distance Education-TOJDE has been issued on the web site http://tojde.anadolu.edu.tr now. TOJDE is meeting with its readers for the 14th time, since 2000 January.First of all I would like to inform you once more that Volume 5 Number:3 will publish as a special theme issue of TOJDE. This issue will be prepare by Patrick Alan DANAHER, Fons NOUWENS, from Learning, Evaluation, Innovation and Development (LEID Centre, within the Division of Teaching and Learning Services, at Central Queensland University (CQU in Australia and Zeynep ERDINC from Anadolu University as a guest co-editors. Call for papers for taht issue finished at 15th March. Now, the selected articles are in reviewing and evaluation phase in process. In this issue, has been given place to two note for editor, eight articles, three book reviews, 9 news, and as being before three links deal with Anadolu University take place in the literature and introducing a journal dealt with DE application. This issue's articles came from Canada, Greece, Turkey and USA (according to alphabetical order.

  14. Prosthetics / Limb Loss

    Science.gov (United States)

    ... implant to encourage the sealing process. Implanting titanium prosthetic components avoids the need for a socket. But preventing bacterial invasion and infection is a key challenge, one that this research ...

  15. 29 CFR 793.8 - “News editor.”

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false âNews editor.â 793.8 Section 793.8 Labor Regulations... INTERPRETATION NOT DIRECTLY RELATED TO REGULATIONS EXEMPTION OF CERTAIN RADIO AND TELEVISION STATION EMPLOYEES... Exemption § 793.8 “News editor.” A news editor is an employee who gathers, edits and rewrites the news. He...

  16. Review of Prosthetic Joint Infection from Listeria monocytogenes.

    Science.gov (United States)

    Bader, Gilbert; Al-Tarawneh, Mohammed; Myers, James

    2016-12-01

    Prosthetic joint infection from Listeria monocytogenes is rare. We decided to shed light on this illness and review the reported cases to better understand its characteristics. We conducted a comprehensive review of the English literature using PubMed. We also included one case that we had managed. We found 25 cases of prosthetic joint infection from L. monocytogenes reported individually and a retrospective study of 43 cases of joint and bone listerial infection, including 34 with prosthetic joint infection, conducted in France. We have described their clinical and para-clinical features and tried to elaborate on the pathophysiology, treatment, and prevention. Prosthetic joint infection from L. monocytogenes is mainly late. Systemic inflammation may be absent. Although rare, it must be suspected in patients at high risk for both prosthetic joint and listerial infections. In addition, those patients must be instructed on appropriate preventive measures.

  17. Editor's Note

    African Journals Online (AJOL)

    On another note: the editor and the editorial team acknowledge the financial support of the Carnegie Corporation of New York through the University of Ghana Building A New Generation of Academics in Africa (BANGA-Africa) Project. We also use this platform to express our gratitude for the support of various stakeholders, ...

  18. Pannus-related prosthetic valve dysfunction. Case report.

    Science.gov (United States)

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  19. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  20. Validation of the prosthetic esthetic index

    DEFF Research Database (Denmark)

    Özhayat, Esben B; Dannemand, Katrine

    2014-01-01

    OBJECTIVES: In order to diagnose impaired esthetics and evaluate treatments for these, it is crucial to evaluate all aspects of oral and prosthetic esthetics. No professionally administered index currently exists that sufficiently encompasses comprehensive prosthetic esthetics. This study aimed...... to validate a new comprehensive index, the Prosthetic Esthetic Index (PEI), for professional evaluation of esthetics in prosthodontic patients. MATERIAL AND METHODS: The content, criterion, and construct validity; the test-retest, inter-rater, and internal consistency reliability; and the sensitivity...... furthermore distinguish between participants and controls, indicating sufficient sensitivity. CONCLUSION: The PEI is considered a valid and reliable instrument involving sufficient aspects for assessment of the professionally evaluated esthetics in prosthodontic patients. CLINICAL RELEVANCE...

  1. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  2. EDITORIAL: Greetings from the new Editor-in-Chief Greetings from the new Editor-in-Chief

    Science.gov (United States)

    Nielsch, Kornelius

    2012-01-01

    On 1 January 2012 I will be assuming the position of Editor-in-Chief of the journal Semiconductor Science and Technology (SST). I am flattered by the confidence expressed in my ability to carry out this challenging job and I will try hard to justify this confidence. The previous Editor-in-Chief, Laurens Molenkamp, University of Würzburg, Germany, has worked tirelessly for the last ten years and has done an excellent job for the journal. Everyone at the journal is profoundly grateful for his leadership and for his achievements In 2012 several new members will join the Editorial Board: Professor Deli Wang (University of California, San Diego) with considerable expertise in semiconductor nanowires, Professor Saskia Fischer (Humboldt University, Berlin, Germany) with a background in semiconductor quantum devices, and Professor Erwin Kessels (Eindhoven University of Technology, Netherlands) with extensive experience in plasma processing of thin films and gate oxides. In particular, I want to express my gratitude to Professor Israel Bar-Joseph (Weizmann Institute of Science, Israel) and Professor Maria Tamargo (The City College of New York, USA), who will leave next year and who have vigorously served the Editorial Board for years. The journal has recently introduced a fast-track option for manuscripts. This option is a high-quality, high-profile outlet for new and important research across all areas of semiconductor research. Authors can expect to receive referee reports in less than 20 days from submission. Once accepted, you can expect the articles to be online within two or three weeks from acceptance and to be published in print in less than a month. Furthermore, all fast-track communications published in 2011 will be free to read for ten years. More detailed information on fast-track publication can be found on the following webpage: http://iopscience.iop.org/0268-1242/page/Fast track communications It is encouraging to see that since the journal introduced pre

  3. Effective gene editing by high-fidelity base editor 2 in mouse zygotes

    Directory of Open Access Journals (Sweden)

    Puping Liang

    2017-06-01

    Full Text Available ABSTRACT Targeted point mutagenesis through homologous recombination has been widely used in genetic studies and holds considerable promise for repairing disease-causing mutations in patients. However, problems such as mosaicism and low mutagenesis efficiency continue to pose challenges to clinical application of such approaches. Recently, a base editor (BE system built on cytidine (C deaminase and CRISPR/Cas9 technology was developed as an alternative method for targeted point mutagenesis in plant, yeast, and human cells. Base editors convert C in the deamination window to thymidine (T efficiently, however, it remains unclear whether targeted base editing in mouse embryos is feasible. In this report, we generated a modified high-fidelity version of base editor 2 (HF2-BE2, and investigated its base editing efficacy in mouse embryos. We found that HF2-BE2 could convert C to T efficiently, with up to 100% biallelic mutation efficiency in mouse embryos. Unlike BE3, HF2-BE2 could convert C to T on both the target and non-target strand, expanding the editing scope of base editors. Surprisingly, we found HF2-BE2 could also deaminate C that was proximal to the gRNA-binding region. Taken together, our work demonstrates the feasibility of generating point mutations in mouse by base editing, and underscores the need to carefully optimize base editing systems in order to eliminate proximal-site deamination.

  4. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  5. Management of Prosthetic Joint Infection.

    Science.gov (United States)

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Which prosthetic foot to prescribe?

    OpenAIRE

    De Asha, AR; Barnett, CT; Struchkov, V; Buckley, JG

    2017-01-01

    Introduction: \\ud Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to pa...

  7. DOSSIER: Intelectuales y Editores

    Directory of Open Access Journals (Sweden)

    Gustavo Sorá

    2009-04-01

    Full Text Available El intelectual abre ideas, el editor las cierra. El escritor produce textos, el editor impresos. El intelectualescribe pero es el editor quien publica. No por nada, afirman algunos psicólogos, el pensamientoculmina con su publicación. Entre el escritor y el editor se moviliza una energía simbólica y socialsublimada bajo las líneas impresas que llegan al lector. Ese entre-lugar de producción de sentidos, decosmologías, de sociedad que marcó la formación de gran parte de las culturas desde la aparición de laexpresión gráfica de las ideas, permanece como un problema esquivo para la investigación, al menospara la antropología practicada en estas latitudes. Parece una cuestión obturada por el dominanteacúmulo de historias de las ideas, de la literatura, del pensamiento que reactualizan la oposición entreespíritu y materia, estética y sociedad, texto y contexto. Evidencia de ello es la clausura sufrida por lasociología de la literatura, una sub-disciplina tan incómoda para los guardianes del aura del genioliterario nacional.Este dossier busca iluminar esa relación con la certeza de que modela uno de los terrenos másfértiles para repensar el legado de la historia de la cultura en occidente y para generar un basto programade problemas de investigación escasamente explorados por las ciencias sociales y humanas en AméricaLatina, y aplicables al estudio de toda cultura, con o sin escritura.

  8. New Editors Appointed for Sections of Journal of Geophysical Research

    Science.gov (United States)

    2009-04-01

    New editors have been appointed for the Atmospheres, Biogeosciences, and Oceans sections of the Journal of Geophysical Research (JGR). Joost de Gouw (NOAA, Boulder, Colo.) and Renyi Zhang (Texas A&M, College Station) are filling the vacancies of retiring Atmospheres section editors John Austin and Jose Fuentes. De Gouw and Zhang join the continuing editors Steven Ghan and Yinon Rudich. Sara Pryor (Indiana University, Bloomington) is joining the Atmospheres section editorial board as an associate editor now; she will transition to editor in January 2010.

  9. Bruxism and prosthetic treatment: a critical review.

    Science.gov (United States)

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  11. Announcement: New Editor-In Robert C. Kennicutt

    Science.gov (United States)

    Abt, Helmut A.

    1999-06-01

    Effective 1999 July 1, all new manuscripts for Part 1 of The Astrophysical Journal and The Astrophysical Journal Supplement Series should be sent to Dr. Robert C. Kennicutt, Editor-in-Chief The Astrophysical Journal Steward Observatory University of Arizona Tucson, AZ 85721-0065 The other means of contact are telephone, (520) 621-5145 FAX, (520) 621-5153 and e-mail, apj@as.arizona.edu. For express packages please use the street address of 933 North Cherry Avenue. Dr. Kennicutt will be assisted by several of my loyal coworkers, who will move across the street. Manuscripts received before July 1 will be handled by the current editor until most of their problems have been resolved, at which point the remainder will be sent to Dr. Kennicutt's office. Manuscripts for the Letters should, as before, be sent directly to Dr. Alex Dalgarno at the Center for Astrophysics in Cambridge, MA. We are fortunate that a person with as much experience in research and proven good judgment as Dr. Kennicutt is willing to accept this difficult and time-consuming responsibility. He will be only the seventh Managing Editor or Editor-in-Chief that this Journal has had in its 104 years. Please give him the cooperation and help that you have given the current editor. It has been my privilege to work for 28 years with many of the best astrophysicists in the world and to publish their papers. This was done with the help of the AAS Publications Board and AAS officers, the efforts of Peter Boyce and Evan Owens who made the on-line edition of the Journal possible, three Associate Editors, a score of Scientific Editors, a hardworking staff of six in Tucson, up to 25 production controllers and manuscript editors at the University of Chicago Press, and the thousands of astronomers throughout the world who served as referees. The original masthead called this journal ``An International Review of Spectroscopy and Astronomical Physics.'' That subtitle is no longer appropriate because we do not publish

  12. Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases.

    Science.gov (United States)

    Barut, Nicolas; Anract, Philippe; Babinet, Antoine; Biau, David

    2015-09-01

    Tumour hip and knee endoprostheses have become the mainstay for reconstruction of patients with bone tumours. Fixation into host bone has improved over time. However, some patients present with a peri-prosthetic fracture over follow-up. The objective of this study was to analyse the mode of presentation and survival of implant after a peri-prosthetic fracture around a tumour endoprosthesis. Eighteen peri-prosthetic fractures (17 patients) were included. All patients were treated at a tertiary care center. There were 11 (65%) women; the median age at the time of fracture was 38 years old. All implants were cemented and all knee endoprostheses were fixed-hinge. Twelve (67%) fractures occurred after femoral resection and six (33%) fractures after proximal tibial resection. There were three femoral neck fractures (UCS C), three femoral shaft type C fractures, two femoral shaft type B1, one tibial shaft type B2, three tibial shaft type C, three ankle fractures (UCS C) and three patella fractures (UCS F). Two fractures were treated conservatively and 16 were operated on. Only one patient had the implant revised. There were eight (44%) failures over follow-up; none of the conservative treatment failed. The cumulative probability of failure for any reason was 27% (8-52) and 55% (22-79) at five and ten years, respectively. Peri-prosthetic fractures around massive endoprostheses are different from that of standard implants. There are more type C fractures; internal fixation is an attractive option at the time of presentation but the risk of revision over follow-up is high and patients should be informed accordingly.

  13. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  14. Synovial Calprotectin: An Inexpensive Biomarker to Exclude a Chronic Prosthetic Joint Infection.

    Science.gov (United States)

    Wouthuyzen-Bakker, Marjan; Ploegmakers, Joris J W; Ottink, Karsten; Kampinga, Greetje A; Wagenmakers-Huizenga, Lucie; Jutte, Paul C; Kobold, Anneke C M

    2018-04-01

    To diagnose or exclude a chronic prosthetic joint infection (PJI) can be a clinical challenge. Therefore, sensitive and specific biomarkers are needed in the diagnostic work-up. Calprotectin is a protein with antimicrobial properties and is released by activated neutrophils, making it a specific marker for infection. Because of its low costs and ability to obtain a quantitative value as a point of care test, it is an attractive marker to use in clinical practice. In addition, the test is already used in routine care in most hospitals for other indications and therefore easy to implement. Between June 2015 and June 2017 we collected synovial fluid of all consecutive patients who underwent revision surgery of a prosthetic joint because of chronic pain with or without prosthetic loosening. Synovial calprotectin was measured using a lateral flow immunoassay. A PJI was defined by the diagnostic criteria described by the Musculoskeletal Infection Society. Fifty-two patients with chronic pain were included. A PJI was diagnosed in 15 of 52 (29%) patients. The median calprotectin in the PJI group was 859 mg/L (interquartile range 86-1707) vs 7 mg/L (interquartile range 3-25) in the control group (P < .001). With a cut-off value of 50 mg/L, synovial calprotectin showed a sensitivity, specificity, positive predictive value, and negative predictive value of 86.7%, 91.7%, 81.3%, and 94.4%, respectively. Synovial calprotectin is a useful and cheap biomarker to use in the diagnostic work-up of patients with chronic pain, especially to exclude a PJI prior to revision surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Prosthetic management of deciduous teeth

    OpenAIRE

    Bassil, Jean

    2015-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária Introduction: Situations of single or multiple edentulous are not an exception during childhood. Prosthetic management is necessary in case of absence of replacing tooth or when its eruption is planned too far in time. Indications of prosthetic rehabilitation for children are multiple and rise from the etiologic factors caus...

  16. 100 top-cited scientific papers in limb prosthetics.

    Science.gov (United States)

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq; Shadgan, Babak

    2013-11-17

    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.

  17. Responsiveness of the Prosthetic Esthetic Scale

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov

    2017-01-01

    Objectives The aim of the study was to evaluate the responsiveness of the Prosthetic Esthetic Index (PEI) in a population who received prosthetic replacements. Materials and methods Fifty-seven patients who received prosthetic replacement of at least one tooth by means of fixed or removable...... prosthesis were professionally esthetically evaluated using the PEI and the Dental Aesthetic Index (DAI) before and after treatment. The participants further evaluated their oral esthetics using the Oral Health Impact Profile Aesthetic (OHIP-Aes) and Orofacial Esthetic Index (OES). Responsiveness......-Aes and OES scores. The PEI was more consistent in responsiveness than the DAI. Conclusions The PEI shows sufficient responsiveness for use in longitudinal studies and for use as a follow-up measure in clinical practice. Clinical relevance The PEI can in a standardized manner monitor and document esthetic...

  18. Stiffness and hysteresis properties of some prosthetic feet

    OpenAIRE

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the hysteresis, which are the topics of this paper, are not properly prescribed, but could be adapted to improve the prosthetic walking performance. The shape is strongly related to the cosmetic appearance a...

  19. pedigreejs: a web-based graphical pedigree editor.

    Science.gov (United States)

    Carver, Tim; Cunningham, Alex P; Babb de Villiers, Chantal; Lee, Andrew; Hartley, Simon; Tischkowitz, Marc; Walter, Fiona M; Easton, Douglas F; Antoniou, Antonis C

    2018-03-15

    The collection, management and visualization of clinical pedigree (family history) data is a core activity in clinical genetics centres. However, clinical pedigree datasets can be difficult to manage, as they are time consuming to capture, and can be difficult to build, manipulate and visualize graphically. Several standalone graphical pedigree editors and drawing applications exist but there are no freely available lightweight graphical pedigree editors that can be easily configured and incorporated into web applications. We developed 'pedigreejs', an interactive graphical pedigree editor written in JavaScript, which uses standard pedigree nomenclature. Pedigreejs provides an easily configurable, extensible and lightweight pedigree editor. It makes use of an open-source Javascript library to define a hierarchical layout and to produce images in scalable vector graphics (SVG) format that can be viewed and edited in web browsers. The software is freely available under GPL licence (https://ccge-boadicea.github.io/pedigreejs/). tjc29@cam.ac.uk. Supplementary data are available at Bioinformatics online.

  20. Graphical Editor of the DDS Topology Configuration

    CERN Document Server

    Rusinov, Aleksandar

    2015-01-01

    An editor for the DDS topology configuration is created to allow the viewing of an existing topology, the editing of a topology, the creation of a new topology and the saving of a topology as a topology language XML file to be run directly on DDS or to be reloaded again for further editing. The development of the editor was started at GSI Darmstadt at the end of last year. The editor is designed as a web application that works on the client side. Recent and powerful JavaScript libraries were used – ReactJS and JointJS. It has two menus for editing – one for the declarative part and another for the executable part. A graph visualisation of the topology has also been developed and implemented fully to the editor. The output files have been tested and fully verified on the DDS. Future work will involve representation of the pipeline process and investigation on behavior when larger and more sophisticated topologies are used.

  1. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  2. Tomographic and echocardiographic diagnosis of mitral prosthetic valve thrombosis

    International Nuclear Information System (INIS)

    Sainz Gonzalez de la Penna, Benito; Ramos Gutierrez, Luis Benito; Gonzalez Artiles, Iovank

    2010-01-01

    Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient

  3. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Science.gov (United States)

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  4. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  5. Antithrombotic Therapy in Patients with Prosthetic Heart Valves

    Directory of Open Access Journals (Sweden)

    Mohamed HA

    2009-01-01

    Full Text Available Patients with mechanical valve prostheses require a lifelong anticoagulant treatment. The combined use of Warfarin and low-dose aspirin appears to reduce the risk of valve thrombosis and systemic embolism at a low risk of bleeding. The management of women with prosthetic heart valves during pregnancy poses a particular challenge, as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants, such as Warfarin, cause foetal embryopathy; unfractionated heparin and low-molecular-weight heparin have been reported to be ineffective in preventing thromboembolic complications.This article discusses the available data and the most recent guidelines in the antithrombotic management of patients with prosthetic valves, and antithrombotic therapy in various clinical situations such as pregnant women with prosthetic heart valves, and patients with prosthetic heart valves undergoing noncardiac surgery.

  6. Amputation and Prosthetics

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Amputation and Prosthetics Email to a friend * required ...

  7. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  8. Cyborg beast: a low-cost 3d-printed prosthetic hand for children with upper-limb differences.

    Science.gov (United States)

    Zuniga, Jorge; Katsavelis, Dimitrios; Peck, Jean; Stollberg, John; Petrykowski, Marc; Carson, Adam; Fernandez, Cristina

    2015-01-20

    prosthetic hand and the proposed distance-fitting procedures may represent a possible low-cost alternative for children in developing countries and those who have limited access to health care providers. Further studies should examine the functionality, validity, durability, benefits, and rejection rate of this type of low-cost 3D-printed prosthetic device.

  9. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  10. Towards the implementation of a system for manuscript editor certification

    Directory of Open Access Journals (Sweden)

    Hyun Jung Yi

    2016-02-01

    Full Text Available Style and format are important criteria for evaluating a journal and indexing it in major databases. In Korean science, technology, and medical journals, interest in manuscript editing has increased over the past seven to eight years, and the responsibilities of manuscript editors have expanded as well. However, since no clear standards for the roles and qualifications for manuscript editors are yet available, a formal certification system is needed to establish appropriate standards and to provide professional training. To identify ways of developing a manuscript editor certification program in Korea, this study investigated similar certification programs in and outside the country and surveyed 195 Korean editors, manuscript editors, publishers, and medical librarians. The survey revealed that manuscript editors were necessary (mean score of 4.38 on a five-point Likert scale, with a score of 5 indicating strong agreement, and that their main contributions were efficiently managing the editorial board, improving the accuracy of references, and accelerating the editing process. The respondents were also positive about the possibility of implementing a manuscript editor certification; 45.1% showed interest in becoming certified, and 47.1% reported interest in hiring a certified manuscript editor. Regarding the system for issuing certification, respondents favored a professional training course (53.1%, validation of work experience (27.1%, or an examination (16.8%. This study concludes that it is essential to establish a formal certification program to train manuscript editors properly, and an examination system is the most efficient and suitable method for managing the certification process.

  11. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    Science.gov (United States)

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  12. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    Science.gov (United States)

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  13. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  14. From the editors

    NARCIS (Netherlands)

    NN,

    2001-01-01

    Hofstadter’s Law: Things always take longer than you think, even when you take into account Hofstadter’s Law. [D. Hofstadter, Gödel, Escher, Bach: an eternal golden braid (1980) 152]. This certainly applies to the forthcoming issues of the Flora Malesiana. According to its editors the bottleneck

  15. Successful thrombolysis of aortic prosthetic valve thrombosis during ...

    African Journals Online (AJOL)

    Successful thrombolysis of aortic prosthetic valve thrombosis during first trimester of pregnancy. A Shukla, AP Raval, R Shah. Abstract. Prosthetic heart valve thrombosis during pregnancy is life-threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we ...

  16. Welding of Prosthetic Alloys

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-04-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  17. Ten questions on prosthetic shoulder infection.

    Science.gov (United States)

    Pinder, Elizabeth M; Ong, Joshua Cy; Bale, R Stephen; Trail, Ian A

    2016-07-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes.

  18. Academic Degradation and the Retreat of the Editors: Academic Irregularities and the Spreading of Academic Corruption from an Editor's Perspective

    Science.gov (United States)

    Xun, Gong

    2007-01-01

    Against the backdrop of the grave academic crisis in China, editors have become the objects of wooing, favor-currying, connections-seeking, and collusions; they have been targeted for attacks, plots, extortions, and encroachments. Editing and publishing have become avenues for academic irregularities and academic corruption. Editors have the power…

  19. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025... intended for medical purposes to support, protect, or aid in the use of a cast, orthosis (brace), or prosthesis. Examples of prosthetic and orthotic accessories include the following: A pelvic support band and...

  20. Undergraduate prosthetics and orthotics teaching methods: A baseline for international comparison.

    Science.gov (United States)

    Aminian, Gholamreza; O'Toole, John M; Mehraban, Afsoon Hassani

    2015-08-01

    Education of Prosthetics and Orthotics is a relatively recent professional program. While there has been some work on various teaching methods and strategies in international medical education, limited publication exists within prosthetics and orthotics. To identify the teaching and learning methods that are used in Bachelor-level prosthetics and orthotics programs that are given highest priority by expert prosthetics and orthotics instructors from regions enjoying a range of economic development. Mixed method. The study partly documented by this article utilized a mixed method approach (qualitative and quantitative methods) within which each phase provided data for other phases. It began with analysis of prosthetics and orthotics curricula documents, which was followed by a broad survey of instructors in this field and then a modified Delphi process. The expert instructors who participated in this study gave high priority to student-centered, small group methods that encourage critical thinking and may lead to lifelong learning. Instructors from more developed nations placed higher priority on student's independent acquisition of prosthetics and orthotics knowledge, particularly in clinical training. Application of student-centered approaches to prosthetics and orthotics programs may be preferred by many experts, but there appeared to be regional differences in the priority given to different teaching methods. The results of this study identify the methods of teaching that are preferred by expert prosthetics and orthotics instructors from a variety of regions. This treatment of current instructional techniques may inform instructor choice of teaching methods that impact the quality of education and improve the professional skills of students. © The International Society for Prosthetics and Orthotics 2014.

  1. Data Sharing: A New Editorial Initiative of the International Committee of Medical Journal Editors. Implications for the Editors´ Network.

    Science.gov (United States)

    Alfonso, Fernando; Adamyan, Karlen; Artigou, Jean-Yves; Aschermann, Michael; Boehm, Michael; Buendia, Alfonso; Chu, Pao-Hsien; Cohen, Ariel; Cas, Livio Dei; Dilic, Mirza; Doubell, Anton; Echeverri, Dario; Enç, Nuray; Ferreira-González, Ignacio; Filipiak, Krzysztof J; Flammer, Andreas; Fleck, Eckart; Gatzov, Plamen; Ginghina, Carmen; Goncalves, Lino; Haouala, Habib; Hassanein, Mahmoud; Heusch, Gerd; Huber, Kurt; Hulín, Ivan; Ivanusa, Mario; Krittayaphong, Rungroj; Lau, Chu-Pak; Marinskis, Germanas; Mach, François; Moreira, Luiz Felipe; Nieminen, Tuomo; Oukerraj, Latifa; Perings, Stefan; Pierard, Luc; Potpara, Tatjana; Reyes-Caorsi, Walter; Rim, Se-Joong; Rødevand, Olaf; Saade, Georges; Sander, Mikael; Shlyakhto, Evgeny; Timuralp, Bilgin; Tousoulis, Dimitris; Ural, Dilek; Piek, J J; Varga, Albert; Lüscher, Thomas F

    2017-05-01

    The International Committee of Medical Journal Editors (ICMJE) provides recommendations to improve the editorial standards and scientific quality of biomedical journals. These recommendations range from uniform technical requirements to more complex and elusive editorial issues including ethical aspects of the scientific process. Recently, registration of clinical trials, conflicts of interest disclosure, and new criteria for authorship - emphasizing the importance of responsibility and accountability-, have been proposed. Last year, a new editorial initiative to foster sharing of clinical trial data was launched. This review discusses this novel initiative with the aim of increasing awareness among readers, investigators, authors and editors belonging to the Editors´ Network of the European Society of Cardiology. Resumo O Comitê Internacional de Editores de Revistas Médicas (ICMJE) fornece recomendações para aprimorar o padrão editorial e a qualidade científica das revistas biomédicas. Tais recomendações variam desde requisitos técnicos de uniformização até assuntos editoriais mais complexos e elusivos, como os aspectos éticos do processo científico. Recentemente, foram propostos registro de ensaios clínicos, divulgação de conflitos de interesse e novos critérios de autoria, enfatizando a importância da responsabilidade e da responsabilização. No último ano, lançou-se uma nova iniciativa editorial para fomentar o compartilhamento dos dados de ensaios clínicos. Esta revisão discute essa nova iniciativa visando a aumentar a conscientização de leitores, investigadores, autores e editores filiados à Rede de Editores da Sociedade Europeia de Cardiologia.

  2. From Editor vol 11, No.4

    OpenAIRE

    Ugur Demiray

    2010-01-01

    Greetings Dear readers of TOJDE,TOJDE is appeared on your screen now as Volume 11, Number: 4. In this issue it is published 4 notes for Editor, 12 articles, 2 book and one conference reviews. And this time, 27 authors from 10 different countries are placed. These published articles are from Bangldesh, Greece, India, Israel, Malaysia, Nigeria, Portugal, Singapore, Turkey and USA.The first Notes for editor arrived from USA, written by Kevin YEE and Jace HARGIS. They focused on PREZI: A Differen...

  3. Announcement: New Editor-in-Chief Robert C. Kennicutt

    Science.gov (United States)

    Abt, Helmut A.

    1999-05-01

    Effective 1999 July 1, all new manuscripts for Part 1 of The Astrophysical Journal and The Astrophysical Journal Supplement Series should be sent to Dr. Robert C. Kennicutt, Editor-in-Chief The Astrophysical Journal Steward Observatory University of Arizona Tucson, AZ 85721-0065 The other means of contact are telephone, (520) 621-5145 FAX, (520) 621-5153 and e-mail, apj@as.arizona.edu. For express packages please use the street address of 933 North Cherry Avenue. Dr. Kennicutt will be assisted by several of my loyal coworkers, who will move across the street. Manuscripts received before July 1 will be handled by the current editor until most of their problems have been resolved, at which point the remainder will be sent to Dr. Kennicutt's office. Manuscripts for the Letters should, as before, be sent directly to Dr. Alex Dalgarno at the Center for Astrophysics in Cambridge, MA. We are fortunate that a person with as much experience in research and proven good judgment as Dr. Kennicutt is willing to accept this difficult and time-consuming responsibility. He will be only the seventh Managing Editor or Editor-in-Chief that this Journal has had in its 104 years. Please give him the cooperation and help that you have given the current editor. It has been my privilege to work for 28 years with many of the best astrophysicists in the world and to publish their papers. This was done with the help of the AAS Publications Board and AAS officers, the efforts of Peter Boyce and Evan Owens who made the on-line edition of the Journal possible, three Associate Editors, a score of Scientific Editors, a hardworking staff of six in Tucson, up to 25 production controllers and manuscript editors at the University of Chicago Press, and the thousands of astronomers throughout the world who served as referees. The original masthead called this journal ``An International Review of Spectroscopy and Astronomical Physics.'' That subtitle is no longer appropriate because we do not publish

  4. Rehabilitation and Prosthetic Services

    Science.gov (United States)

    ... Review Resources AT Education Blind Rehab Chiropractic Service Polytrauma/TBI Prosthetics & Sensory Aids Recreation Therapy More Health ... Military Sexual Trauma PTSD Research (MIRECC) Military Exposures Polytrauma Rehabilitation Spinal Cord Injury Telehealth Womens Health Issues ...

  5. Stiffness and hysteresis properties of some prosthetic feet

    NARCIS (Netherlands)

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the

  6. Successful Management of Prosthetic Valve Brucella Endocarditis with Antibiotherapy Alone

    Directory of Open Access Journals (Sweden)

    José Pedro Fonseca

    2018-01-01

    Full Text Available Objectives: To report a case of mechanical aortic prosthesis Brucella endocarditis successfully treated with antibiotics alone. Materials and methods: We describe a clinical case and present a review of the literature. Results: A 60-year-old female farmer with a mechanical aortic prosthetic valve presented with low back pain and fever. She was diagnosed with prosthetic valve Brucella mellitensis endocarditis and was cured with antibiotic therapy alone. Few cases of successfully treated prosthetic valve Brucella endocarditis without surgery have been reported. Conclusion: Prosthetic valve Brucella endocarditis usually requires surgical valve replacement. However, selected patients may be successfully treated with antibiotic therapy alone.

  7. Data Sharing: A New Editorial Initiative of the International Committee of Medical Journal Editors. Implications for the Editors' Network.

    Science.gov (United States)

    Alfonso, Fernando; Adamyan, Karlen; Artigou, Jean-Yves; Aschermann, Michael; Boehm, Michael; Buendia, Alfonso; Chu, Pao-Hsien; Cohen, Ariel; Cas, Livio Dei; Dilic, Mirza; Doubell, Anton; Echeverri, Dario; Enç, Nuray; Ferreira-González, Ignacio; Filipiak, Krzysztof J; Flammer, Andreas; Fleck, Eckart; Gatzov, Plamen; Ginghina, Carmen; Goncalves, Lino; Haouala, Habib; Hassanein, Mahmoud; Heusch, Gerd; Huber, Kurt; Hulín, Ivan; Ivanusa, Mario; Krittayaphong, Rungroj; Lau, Chu-Pak; Marinskis, Germanas; Mach, François; Moreira, Luiz Felipe; Nieminen, Tuomo; Oukerraj, Latifa; Perings, Stefan; Pierard, Luc; Potpara, Tatjana; Reyes-Caorsi, Walter; Rim, Se-Joong; Rødevand, Olaf; Saade, Georges; Sander, Mikael; Shlyakhto, Evgeny; Timuralp, Bilgin; Tousoulis, Dimitris; Ural, Dilek; Piek, J J; Varga, Albert; Lüscher, Thomas F

    The International Committee of Medical Journal Editors (ICMJE) provides recommendations to improve the editorial standards and scientific quality of biomedical journals. These recommendations range from uniform technical requirements to more complex and elusive editorial issues including ethical aspects of the scientific process. Recently, registration of clinical trials, conflicts of interest disclosure, and new criteria for authorship - emphasizing the importance of responsibility and accountability -, have been proposed. Last year, a new editorial initiative to foster sharing of clinical trial data was launched. This review discusses this novel initiative with the aim of increasing awareness among readers, investigators, authors and editors belonging to the Editors' Network of the European Society of Cardiology. Copyright © 2017. Publicado por Masson Doyma México S.A.

  8. The fabulous fours! annual report from the editor

    Directory of Open Access Journals (Sweden)

    Robbins RA

    2015-01-01

    Full Text Available No abstract available. Article truncated after 150 words. With the end of 2014, the Southwest Journal of Pulmonary and Critical Care (SWJPCC completed its fourth year of operation. Our first manuscript was posted on November 11, 2010. We posted 8 manuscripts our first year, 68 in 2011, 113 in 2012 and 164 in 2013 and 167 in 2014 (Table 1. Accompanying our increase in manuscripts, our readership continues to steadily grow, although comparisons to previous years is difficult because the methodology changed in February, 2014 (Table 2. SWJPCC continue to evolve and we made some changes in 2014: The California Thoracic Society partnered with SWJPCC; We added additional associate editors in pulmonary, critical care and imaging from Fresno (Peterson, Albuquerque (Boivin and Tucson (Arteaga. Many need to be thanked. First, thanks to our authors. Second, SWJPCC, like all journals, relies upon expert reviewers in order to publish the highest quality manuscripts. We thank the reviewers for their time ...

  9. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  10. Particle Track Visualization using the MCNP Visual Editor

    International Nuclear Information System (INIS)

    Schwarz, Randolph A.; Carter, Lee; Brown, Wendi A.

    2001-01-01

    The Monte Carlo N-Particle (MCNP) visual editor1,2,3 is used throughout the world for displaying and creating complex MCNP geometries. The visual editor combines the Los Alamos MCNP Fortran code with a C front end to provide a visual interface. A big advantage of this approach is that the particle transport routines for MCNP are available to the visual front end. The latest release of the visual editor by Pacific Northwest National Laboratory enables the user to plot transport data points on top of a two-dimensional geometry plot. The user can plot source points, collisions points, surface crossings, and tally contributions. This capability can be used to show where particle collisions are occurring, verify the effectiveness of the particle biasing, or show which collisions contribute to a tally. For a KCODE (criticality source) calculation, the visual editor can be used to plot the source points for specific cycles

  11. Salmonella Typhimurium gastroenteritis leading to chronic prosthetic vascular graft infection.

    Science.gov (United States)

    Cullinan, Milo; Clarke, Michael; Dallman, Tim; Peart, Steven; Wilson, Deborah; Weiand, Daniel

    2017-08-01

    Introduction. It is estimated up to 6 % of prosthetic vascular grafts become infected. Staphylococcus aureus is predominant in early infection and coagulase-negative staphylococci are predominant in late infections. Enterobacteriaceae cause 14-40 % of prosthetic vascular graft infections. This is, to our knowledge the first reported case of Salmonella gastroenteritis causing chronic prosthetic vascular graft infection (PVGI). Case presentation. A 57 years old lady presented with signs and symptoms of prosthetic vascular graft infection. Three years earlier, she had undergone a prosthetic axillo-femoral bypass graft for critical limb ischaemia. The infected prosthetic vascular graft was removed and Salmonella Typhimurium was isolated on culture. In the intervening period, Salmonella Typhimurium was isolated from a faecal specimen, collected during an episode of acute gastroenteritis. Whole-genome sequencing (WGS) showed that the respective Salmonella Typhimurium isolates differed by only a single nucleotide polymorphism (SNP). Salmonella Typhimurium was not isolated on culture of a faecal specimen collected five days following cessation of antimicrobial therapy. Six months after removal of the prosthetic graft, the patient remains under follow-up for her peripheral vascular disease, which currently requires no further surgical intervention. Conclusion. This case has clear implications for the management of chronic PVGI. It is vital to collect high-quality surgical specimens for microbiological analysis and empirical choices of antibiotics are unlikely to cover all potential pathogens. It may also be prudent to enquire about a history of acute gastroenteritis when assessing patients presenting with chronic PVGI.

  12. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia

    Science.gov (United States)

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-01-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved. PMID:29386978

  13. Enhanced ultrasound for advanced diagnostics, ultrasound tomography for volume limb imaging and prosthetic fitting

    Science.gov (United States)

    Anthony, Brian W.

    2016-04-01

    Ultrasound imaging methods hold the potential to deliver low-cost, high-resolution, operator-independent and nonionizing imaging systems - such systems couple appropriate algorithms with imaging devices and techniques. The increasing demands on general practitioners motivate us to develop more usable and productive diagnostic imaging equipment. Ultrasound, specifically freehand ultrasound, is a low cost and safe medical imaging technique. It doesn't expose a patient to ionizing radiation. Its safety and versatility make it very well suited for the increasing demands on general practitioners, or for providing improved medical care in rural regions or the developing world. However it typically suffers from sonographer variability; we will discuss techniques to address user variability. We also discuss our work to combine cylindrical scanning systems with state of the art inversion algorithms to deliver ultrasound systems for imaging and quantifying limbs in 3-D in vivo. Such systems have the potential to track the progression of limb health at a low cost and without radiation exposure, as well as, improve prosthetic socket fitting. Current methods of prosthetic socket fabrication remain subjective and ineffective at creating an interface to the human body that is both comfortable and functional. Though there has been recent success using methods like magnetic resonance imaging and biomechanical modeling, a low-cost, streamlined, and quantitative process for prosthetic cup design and fabrication has not been fully demonstrated. Medical ultrasonography may inform the design process of prosthetic sockets in a more objective manner. This keynote talk presents the results of progress in this area.

  14. CERN Courier editors through 50 years

    CERN Multimedia

    2009-01-01

    The 50th anniversary of the first publication of the CERN Courier provided the opportunity for a modest celebration on 2 September 2009. All six of the principal editors that the magazine has had over its 50 years met together for the first time. After getting acquainted and re-acquainted over lunch, they gathered in the library at CERN to answer questions about producing the magazine over the years. From right to left, from the first editor to the present incumbent: Roger Anthoine, Alec Hester, Brian Southworth, Gordon Fraser, James Gillies and Christine Sutton.

  15. Prosthetic Status and Prosthetic Need Among the Patients Attending Various Dental Institutes of Ahmedabad and Gandhinagar District, Gujarat

    OpenAIRE

    Shah, Vrinda R.; Shah, Darshana N.; Parmar, Chaitanya H.

    2012-01-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment ...

  16. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review.

    Science.gov (United States)

    Belter, Joseph T; Segil, Jacob L; Dollar, Aaron M; Weir, Richard F

    2013-01-01

    In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are supplemented with a compilation of published data on both commercial and prototype research prosthetic hands. We discuss numerous mechanical design parameters by referencing examples in the literature. Crucial design trade-offs are highlighted, including number of actuators and hand complexity, hand weight, and grasp force. Finally, we offer a set of rules of thumb regarding the mechanical design of anthropomorphic prosthetic hands.

  17. From Editor

    OpenAIRE

    Ugur Demiray

    2009-01-01

    TOJDE is appeared on your screen now as Volume 10, Number: 1. This is the first issue of the year 2009 and 10th anniversary of TOJDE. In this issue it is published four article are in “Notes for Editor Sectio”, 13 articles, 2 reviews. And this time, 26 authors from twelwe different countries are placed. These published articles are from Australia, Botswana, Canada, Italy India, Jordan, Malaysia, Nigeria, Srilanka, USA and Turkey. “Service Learning In Distance Education: Foreign Language Lear...

  18. Table of Contents | Editor | Ghana Journal of Linguistics

    African Journals Online (AJOL)

    2016. Editorial Committee: Ọbádélé Kambon (Editor-in-Chief; University of Ghana). E. Kweku Osam (Consulting Editor; University of Ghana). Gordon S. Adika (University of Ghana). Nana Aba A. Amfo (University of Ghana). Jemima A. Anderson (University of Ghana). Charles O. Marfo (Kwame Nkrumah University of Science ...

  19. PDB Editor: a user-friendly Java-based Protein Data Bank file editor with a GUI.

    Science.gov (United States)

    Lee, Jonas; Kim, Sung Hou

    2009-04-01

    The Protein Data Bank file format is the format most widely used by protein crystallographers and biologists to disseminate and manipulate protein structures. Despite this, there are few user-friendly software packages available to efficiently edit and extract raw information from PDB files. This limitation often leads to many protein crystallographers wasting significant time manually editing PDB files. PDB Editor, written in Java Swing GUI, allows the user to selectively search, select, extract and edit information in parallel. Furthermore, the program is a stand-alone application written in Java which frees users from the hassles associated with platform/operating system-dependent installation and usage. PDB Editor can be downloaded from http://sourceforge.net/projects/pdbeditorjl/.

  20. a worldwide assessment of medical journal editors' practices and ...

    African Journals Online (AJOL)

    responding editors reported having access to the Internet, making participation in ... of improving the quality of medical science and practice.! A critical activity of ... undertook a worldwide survey of medical editors to determine their interest in a ...

  1. Designing Epigenome Editors: Considerations of Biochemical and Locus Specificities.

    Science.gov (United States)

    Sen, Dilara; Keung, Albert J

    2018-01-01

    The advent of locus-specific protein recruitment technologies has enabled a new class of studies in chromatin biology. Epigenome editors enable biochemical modifications of chromatin at almost any specific endogenous locus. Their locus specificity unlocks unique information including the functional roles of distinct modifications at specific genomic loci. Given the growing interest in using these tools for biological and translational studies, there are many specific design considerations depending on the scientific question or clinical need. Here we present and discuss important design considerations and challenges regarding the biochemical and locus specificities of epigenome editors. These include how to account for the complex biochemical diversity of chromatin; control for potential interdependency of epigenome editors and their resultant modifications; avoid sequestration effects; quantify the locus specificity of epigenome editors; and improve locus specificity by considering concentration, affinity, avidity, and sequestration effects.

  2. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    Science.gov (United States)

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  4. Communicating specialized knowledge - negotiating knowledge communication between writer and editor

    DEFF Research Database (Denmark)

    Petersen, Margrethe

    In communicating research findings, authors of academic journal articles face the challenge of overcoming the barriers posed by the knowledge asymmetries between (a) authors and journal readership and (b) authors and editors. Considering the general taxonomy of the submission procedure and the ke...... role of academic journal editors, the issue of whether, regardless of the quality of the submissions received, editors are sometimes insurmountable barriers to knowledge communication should be debated....

  5. From Editor

    OpenAIRE

    Ugur Demiray

    2008-01-01

    Greetings Dear readers of TOJDE, TOJDE is appeared on your screen now as Volume 9, Number: 4. This is the fourth and the last issue of the year 2008. In this issue it is published two notes for Editor, 13 articles, 2 reviews. And this time, 23 authors from seven different countries are placed. These published articles are from Bangladesh, India, Malaysia, Nigeria, Saudi Arabia, USA and Turkey. “Ubiquitous, Free, And Efficient Online Collaboration Tools For Teaching And Learning” has sent to e...

  6. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  7. Current status in development of new EXFOR editor

    International Nuclear Information System (INIS)

    Sarsembayeva, A.; Ebata, S.; Kato, K.; Aikawa, M.; Imai, S.; Chiba, M.; Otuka, N.

    2016-01-01

    A new stand-alone type editor for EXFOR is being developed in Hokkaido University Nuclear Reaction Data Centre (JCPRG). The new editor is designed to allow compilers to save time and to avoid mistakes by using its advanced features. The features included in the latest release are described such as filterable and dynamic suggestion fields. (author)

  8. Surgical-prosthetic treatment of large mandibular cysts

    Directory of Open Access Journals (Sweden)

    Džambas Ljubiša D.

    2003-01-01

    Full Text Available This paper presents a combined surgical-prosthetic procedure of reconstructing mandibular bone defect in a 53 year old patient, following enucleation of a mandibular cyst (Cystectomy Partsch II. After a thorough diagnostic evaluation, a surgical procedure was planned with the particular attention to the nature of the disease, patient’s condition, size and extension of the cyst, tissue loss, and the possibilities of prosthetic management of a mandibular bone defect with partial postresection dental prosthesis. It is of great importance to point to the significance of teamwork of a maxillofacial surgeon and a specialist in prosthodontics. This kind of cooperation provided very effective and less risky soft tissue, as well as bone tissue regeneration (osteogenesis. The patient’s recovery was fast, and he could return to his daily activities and work without significant changes regarding quality of life after surgery and prosthetic treatment.

  9. Prosthetics in Paediatric Dentistry

    Directory of Open Access Journals (Sweden)

    Vulićević Zoran

    2017-07-01

    Full Text Available Premature loss of teeth in children may lead to both functional and esthetic problems. Missing teeth in both anterior and posterior regions may cause malfunctions in mastication and proper pronunciation. If the missing teeth are not replaced, further complications may occur, including adjacent tooth migration, loss of alveolar bone, and irregular occlusion. Considering the sensitive nature of children, loss of teeth may cause the development of insecurities and low self esteem problems. Due to dynamic nature of growth in children and adolescents, prosthetic appliances must not hinder development of orofacial system, and must meet adequate esthetic and functional standards. Dental prosthetic appliances in paediatrics must be planned with respect to the special conditions that led to tooth loss or damage. Multi-disciplinary approach is needed, under constant supervision of paediatric dentist and orthodontist, as well as regular checkups with clinical and radiographical examinations.

  10. Custom-made laser-welded titanium implant prosthetic abutment.

    Science.gov (United States)

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  11. Prosthetic Rehabilitation in Children: An Alternative Clinical Technique

    Directory of Open Access Journals (Sweden)

    Nádia Carolina Teixeira Marques

    2013-01-01

    Full Text Available Complete and partial removable dentures have been used successfully in numerous patients with oligodontia and/or anodontia. However, there is little information in the literature regarding the principles and guidelines to prosthetic rehabilitation for growing children. This case report describes the management of a young child with oligodontia as well as the treatment planning and the prosthetic rehabilitation technique.

  12. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  13. Editor's Note

    Directory of Open Access Journals (Sweden)

    Daniel Shanahan

    2016-07-01

    Full Text Available CORPUS studies have increasingly been of interest to music theorists, musicologists, and music psychology researchers, as is evident in the sheer number of excellent submissions to this special issue. The breadth and depth of these articles, as well as the insightful commentaries, make it seem only fitting to publish over two issues. The current issue contains five articles, eight commentaries, and one research report, and covers folk music, post-tonal music, jazz, Western art music, and the popular music found on Youtube. Eerola presents a model of melodic entropy that provides a nice framework for future information-theoretic work, while Roger Dean and Marcus Pearce present a new approach to modelling pitch-structure in post-tonal music. Frieler, Pfleiderer, Abeßer, and Zaddach give an analysis of jazz solos that demonstrates the role of a narrative arcs in improvisation. White and Quinn present a new corpus that makes use of vast compilations of web-based MIDI data, and demonstrates how such a corpus might be facilitate future musicological and music-theoretic research. Plazak focuses on Youtube as a corpus, and argues that the mutability of such a corpus facilitates our understanding of musical communication, as well as the important role of the listener in defining and re-defining such a dataset. It's encouraging to me both as an editor and practitioner of corpus methods that so many of those heavily involved with the field contributed to these two issues as either an author or a commentator. This issue also brings a number of changes on other fronts. Firstly, Nicola Dibben and Renee Timmers, who served as the journal's editors since Volume 7, have completed their editorial terms. They oversaw the transformation of the journal into a new Open Journal Systems platform, and were able to consistently produce issues that set a very high standard. Under their leadership, the journal both increased its accessibility (we now average more than 1

  14. EDITORIAL: Editor's Farewell

    Science.gov (United States)

    Hudson, R. P.

    1989-01-01

    The completion of Volume 26, 1989, marked the end of my tenure as Editor of Metrologia. My association with the journal, its parent body the Comité International des Poids et Mesures, its host organization the Bureau International des Poids et Mesures, the publishers Springer-Verlag and last (but by no means least) the Editorial Board, has been a pleasant one and I trust that the subscribers will have found the product to be generally satisfactory. There have been, it is true, some disappointments along the way and I shall mention two of these while expressing the hope that the new Editor will enjoy a greater success in their regard. First is the question of circulation, which has stayed dangerously low, although the shrinkage has tapered off in the most recent years. Because of the narrow public support, the costs of production are relatively high and this, through a consequently high subscription rate, tends to enshrine the unsatisfactory state of affairs. Modest schemes to broaden the journal's appeal and bring in a wider readership have foundered upon the first step, namely, that of procuring from staff members of the national standards laboratories the hoped-for articles which would discuss the state of the art in delivering the highest-quality measurement services to the public. However, some very interesting and bolder schemes are presently under discussion. I had also hoped to leaven the journal's content a little by regularly appearing articles on the latest developments within the great national laboratories. But, as with technical review articles, it has proven very difficult to find the right authors who can also spare the time, and only a few laboratories have found it possible to collaborate. In taking my leave, it remains for me to thank all the contributors, referees and readers for their support, to express the hope of an ever brighter future for Metrologia and to wish to the new Editor, Dr D A Blackburn, a happy and successful tenure.

  15. Announcement: New Editor-In-Chief, Robert C. Kennicutt, Jr.

    Science.gov (United States)

    Abt, Helmut A.

    1999-06-01

    Effective 1999 July 1, all new manuscripts for Part 1 of The Astrophysical Journal and The Astrophysical Journal Supplement Series should be sent to Dr. Robert C. Kennicutt, Jr., Editor-in-Chief The Astrophysical Journal Steward Observatory University of Arizona Tucson, AZ 85721-0065 The other means of contact are telephone, (520) 621-5145 FAX, (520) 621-5153 and e-mail, apj@as.arizona.edu. For express packages please use the street address of 933 North Cherry Avenue. Dr. Kennicutt will be assisted by several of my loyal coworkers, who will move across the street. Manuscripts received before July 1 will be handled by the current editor until most of their problems have been resolved, at which point the remainder will be sent to Dr. Kennicutt's office. Manuscripts for the Letters should, as before, be sent directly to Dr. Alex Dalgarno at the Center for Astrophysics in Cambridge, MA. We are fortunate that a person with as much experience in research and proven good judgment as Dr. Kennicutt is willing to accept this difficult and time-consuming responsibility. He will be only the seventh Managing Editor or Editor-in-Chief that this Journal has had in its 104 years. Please give him the cooperation and help that you have given the current editor. It has been my privilege to work for 28 years with many of the best astrophysicists in the world and to publish their papers. This was done with the help of the AAS Publications Board and AAS officers, the efforts of Peter Boyce and Evan Owens who made the on-line edition of the Journal possible, three Associate Editors, a score of Scientific Editors, a hardworking staff of six in Tucson, up to 25 production controllers and manuscript editors at the University of Chicago Press, and the thousands of astronomers throughout the world who served as referees. The original masthead called this journal ``An International Review of Spectroscopy and Astronomical Physics.'' That subtitle is no longer appropriate because we do not

  16. Object class hierarchy for an incremental hypertext editor

    Directory of Open Access Journals (Sweden)

    A. Colesnicov

    1995-02-01

    Full Text Available The object class hierarchy design is considered due to a hypertext editor implementation. The following basic classes were selected: the editor's coordinate system, the memory manager, the text buffer executing basic editing operations, the inherited hypertext buffer, the edit window, the multi-window shell. Special hypertext editing features, the incremental hypertext creation support and further generalizations are discussed.

  17. Peer reviews and the role of a journal editor

    Science.gov (United States)

    Obtaining peer reviews for manuscripts submitted to scientific journals is becoming increasingly difficult. Changes to the system are necessary, and editors must cultivate and maintain a solid base of reviewers to help evaluate journal submissions. This article outlines some steps editors can and sh...

  18. The RAE and Publications: A Review of Journal Editors.

    Science.gov (United States)

    Talib, Ameen Ali

    2000-01-01

    Surveyed editors of academic journals about publication issues related to Britain's Research Assessment Exercise (RAE), a process of grading and funding universities based on published research output. Editors were asked about research quality and output, publication practices, academics' willingness to referee manuscripts, and proliferation of…

  19. Fnom Editor

    OpenAIRE

    Ugur Demiray

    2006-01-01

    Greetings Dear readers of TOJDE, I am pleased to inform you that in the 7th year of TOJDE is appeared as Volume 7, Number: 1 on your screen now as. Very much thanks to all of you once more that we met 21st time, since January 2000. In this issue we published 15 articles, four book reviews, one notes for editor, news and announcements for our readers. And also, we give a place for the Call for Papers to the 4th Special Issue of The Turkish Online Journal of Distance Education (TOJDE) ...

  20. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. The Lives and Hard Times of Magazine Editors in the Big Apple: A Report on the Society of Magazine Editors' Educators Seminar.

    Science.gov (United States)

    English, John W.

    This report chronicles the first Society of Magazine Editors' educators seminar, which was held in New York from May 13-17, 1974, and was attended by ten journalism faculty. The industry's concerns, as expressed through editors, are paper, printing, postage, people, and profit. The Magazine Publishers Association (MPA) seems mostly concerned with…

  2. Workbench surface editor of brain cortical surface

    Science.gov (United States)

    Dow, Douglas E.; Nowinski, Wieslaw L.; Serra, Luis

    1996-04-01

    We have developed a 3D reach-in tool to manually reconstruct 3D cortical surface patches from 2D brain atlas images. The first application of our cortex editor is building 3D functional maps, specifically Brodmann's areas. This tool may also be useful in clinical practice to adjust incorrectly mapped atlas regions due to the deforming effect of lesions. The cortex editor allows a domain expert to control the correlation of control points across slices. Correct correlation has been difficult for 3D reconstruction algorithms because the atlas slices are far apart and because of the complex topology of the cortex which differs so much from slice to slice. Also, higher precision of the resulting surfaces is demanded since these define 3D brain atlas features upon which future stereotactic surgery may be based. The cortex editor described in this paper provides a tool suitable for a domain expert to use in defining the 3D surface of a Brodmann's area.

  3. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  4. A scoping review of competencies for scientific editors of biomedical journals.

    Science.gov (United States)

    Galipeau, James; Barbour, Virginia; Baskin, Patricia; Bell-Syer, Sally; Cobey, Kelly; Cumpston, Miranda; Deeks, Jon; Garner, Paul; MacLehose, Harriet; Shamseer, Larissa; Straus, Sharon; Tugwell, Peter; Wager, Elizabeth; Winker, Margaret; Moher, David

    2016-02-02

    Biomedical journals are the main route for disseminating the results of health-related research. Despite this, their editors operate largely without formal training or certification. To our knowledge, no body of literature systematically identifying core competencies for scientific editors of biomedical journals exists. Therefore, we aimed to conduct a scoping review to determine what is known on the competency requirements for scientific editors of biomedical journals. We searched the MEDLINE®, Cochrane Library, Embase®, CINAHL, PsycINFO, and ERIC databases (from inception to November 2014) and conducted a grey literature search for research and non-research articles with competency-related statements (i.e. competencies, knowledge, skills, behaviors, and tasks) pertaining to the role of scientific editors of peer-reviewed health-related journals. We also conducted an environmental scan, searched the results of a previous environmental scan, and searched the websites of existing networks, major biomedical journal publishers, and organizations that offer resources for editors. A total of 225 full-text publications were included, 25 of which were research articles. We extracted a total of 1,566 statements possibly related to core competencies for scientific editors of biomedical journals from these publications. We then collated overlapping or duplicate statements which produced a list of 203 unique statements. Finally, we grouped these statements into seven emergent themes: (1) dealing with authors, (2) dealing with peer reviewers, (3) journal publishing, (4) journal promotion, (5) editing, (6) ethics and integrity, and (7) qualities and characteristics of editors. To our knowledge, this scoping review is the first attempt to systematically identify possible competencies of editors. Limitations are that (1) we may not have captured all aspects of a biomedical editor's work in our searches, (2) removing redundant and overlapping items may have led to the

  5. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  6. Functional and Psychosocial Outcomes of Hand Transplantation Compared with Prosthetic Fitting in Below-Elbow Amputees: A Multicenter Cohort Study.

    Directory of Open Access Journals (Sweden)

    Stefan Salminger

    Full Text Available Hand-transplantation and improvements in the field of prostheses opened new frontiers in restoring hand function in below-elbow amputees. Both concepts aim at restoring reliable hand function, however, the indications, advantages and limitations for each treatment must be carefully considered depending on level and extent of amputation. Here we report our findings of a multi-center cohort study comparing hand function and quality-of-life of people with transplanted versus prosthetic hands.Hand function in amputees with either transplant or prostheses was tested with Action Research Arm Test (ARAT, Southampton Hand Assessment Procedure (SHAP and the Disabilities of the Arm, Shoulder and Hand measure (DASH. Quality-of-life was compared with the Short-Form 36 (SF-36.Transplanted patients (n = 5 achieved a mean ARAT score of 40.86 ± 8.07 and an average SHAP score of 75.00 ± 11.06. Prosthetic patients (n = 7 achieved a mean ARAT score of 39.00 ± 3.61 and an average SHAP score of 75.43 ± 10.81. There was no significant difference between transplanted and prosthetic hands in ARAT, SHAP or DASH. While quality-of-life metrics were equivocal for four scales of the SF-36, transplanted patients reported significantly higher scores in "role-physical" (p = 0.006, "vitality" (p = 0.008, "role-emotional" (p = 0.035 and "mental-health" (p = 0.003.The indications for hand transplantation or prosthetic fitting in below-elbow amputees require careful consideration. As functional outcomes were not significantly different between groups, patient's best interests and the route of least harm should guide treatment. Due to the immunosuppressive side-effects, the indication for allotransplantation must still be restrictive, the best being bilateral amputees.

  7. Adapting to change: influence of a microprocessor-controlled prosthetic knee on gait adaptations

    NARCIS (Netherlands)

    Prinsen, Erik Christiaan

    2016-01-01

    Advancement in prosthetic knee design have led to the introduction of microprocessor-controlled prosthetic knees (MPKs). MPKs incorporate sensors that are able to measure prosthetic loading, the knee angle, and knee angular velocity. Based on the sensor information, MPKs determine the optimal level

  8. Letter to the editors

    African Journals Online (AJOL)

    2012-10-19

    Oct 19, 2012 ... (interleukin 10 (IL10), Tumor necrosis factor alpha (TNF- alpha) and interferon gamma (IFN-gamma) were done. ... 2. To the editors of the Pan African Medical Journal. Rheumatic heart disease (RHD) is a devastating squeal of acute rheumatic fever (ARF) in Africa. .... Gorgulu S, Eren M, Bagirtan B et al.

  9. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  10. Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2006-09-01

    Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.

  11. Image segmentation for enhancing symbol recognition in prosthetic vision.

    Science.gov (United States)

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  12. Quantifying the effect of editor-author relations on manuscript handling times.

    Science.gov (United States)

    Sarigöl, Emre; Garcia, David; Scholtes, Ingo; Schweitzer, Frank

    2017-01-01

    In this article we study to what extent the academic peer review process is influenced by social relations between the authors of a manuscript and the editor handling the manuscript. Taking the open access journal PlosOne as a case study, our analysis is based on a data set of more than 100,000 articles published between 2007 and 2015. Using available data on handling editor, submission and acceptance time of manuscripts, we study the question whether co-authorship relations between authors and the handling editor affect the manuscript handling time , i.e. the time taken between the submission and acceptance of a manuscript. Our analysis reveals (1) that editors handle papers co-authored by previous collaborators significantly more often than expected at random, and (2) that such prior co-author relations are significantly related to faster manuscript handling. Addressing the question whether these shorter manuscript handling times can be explained by the quality of publications, we study the number of citations and downloads which accepted papers eventually accumulate. Moreover, we consider the influence of additional (social) factors, such as the editor's experience, the topical similarity between authors and editors, as well as reciprocal citation relations between authors and editors. Our findings show that, even when correcting for other factors like time, experience, and performance, prior co-authorship relations have a large and significant influence on manuscript handling times, speeding up the editorial decision on average by 19 days.

  13. From the Editor

    Directory of Open Access Journals (Sweden)

    Ugur Demiray

    2007-04-01

    Full Text Available I am pleased to inform you that in the 8th year of TOJDE are appeared on your screen now as Volume 8, Number: 2. In this issue we published one notes for Editor, 14 articles, two reviews, news and announcements for our readers. 27 authors from ten different countries are placed in this issue. These published articles are from Australia, Bahrain, Bangladesh; Canada Indonesia, Malaysia, Pakistan, Turkey, UK and USA.

  14. From the editor's desk

    Indian Academy of Sciences (India)

    Ever since the Indian Academy of Sciences inherited the publication of the Journal of Genetics from J. B. S. Haldane, successive Editors-in-Chief, Profs H. Sharat Chandra, K. VijayRaghavan, Amitabh Joshi and Rajiva Raman, with the support of members of the editorial board, have not only sustained but also expanded the ...

  15. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    Science.gov (United States)

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  16. EDITORIAL: Message from the Editor Message from the Editor

    Science.gov (United States)

    Thomas, Paul

    2011-01-01

    As usual, being an even year, the 23rd IAEA Fusion Energy Conference took place at Daejeon, Korea. The event was notable not just for the quality of the presentations but also for the spectacular opening ceremony, in the presence of the Prime Minister, Kim Hwang-sik. The Prime Minister affirmed the importance of research into fusion energy research and pledged support for ITER. Such political visibility is good news, of course, but it brings with it the obligation to perform. Fortunately, good performance was much in evidence in the papers presented at the conference, of which a significant proportion contain 'ITER' in the title. Given this importance of ITER and the undertaking by the Nuclear Fusion journal to publish papers associated with Fusion Energy Conference presentations, the Nuclear Fusion Editorial Board has decided to adopt a simplified journal scope that encompasses technology papers more naturally. The scope is available from http://iopscience.iop.org/0029-5515/page/Journal%20information but is reproduced here for clarity: Nuclear Fusion publishes articles making significant advances to the field of controlled thermonuclear fusion. The journal scope includes: the production, heating and confinement of high temperature plasmas; the physical properties of such plasmas; the experimental or theoretical methods of exploring or explaining them; fusion reactor physics; reactor concepts; fusion technologies. The key to scope acceptability is now '....significant advances....' rather than any particular area of controlled thermonuclear fusion research. It is hoped that this will make scope decisions easier for the Nuclear Fusion office, the referees and the Editor.The Nuclear Fusion journal has continued to make an important contribution to the research programme and has maintained its position as the leading journal in the field. This is underlined by the fact that Nuclear Fusion has received an impact factor of 4.270, as listed in ISI's 2009 Science Citation

  17. Development of novel 3D-printed robotic prosthetic for transradial amputees.

    Science.gov (United States)

    Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A

    2016-06-01

    Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.

  18. Prosthetic prescription in the Netherlands: An interview with clinical experts

    NARCIS (Netherlands)

    Van Der Linde, H.; Geertzen, J.H.B.; Hofstad, C.J.; Van Limbeek, Jacques; Postema, K.

    2004-01-01

    In the process of guideline development for prosthetic prescription in the Netherlands the authors made a study of the daily clinical practice of lower limb prosthetics. Besides the evidence-based knowledge from literature the more implicit knowledge from clinical experts is of importance for

  19. PLANNING OF IMPLANTO‐PROSTHETIC STRUCTURES IN TOTAL EDENTATION ACCORDING TO BIOMECHANICAL CRITERIA

    Directory of Open Access Journals (Sweden)

    N. VASILE

    2013-07-01

    Full Text Available Scope of the study: Analysis of the biomechanical aspects of the implanto‐prosthetic structures for planning the treatment in cases of total edentation.Materials and method: The study was performed in the Clinics of Prosthetics and Oral Implantology, Military Emergency Hospital of Sibiu, on a group of mandibularly totally edentated patients. Planning of the implanto‐pros‐ thetic treatment had in view the peculiarities of total man‐ dibular edentation and observance of the biomechanical principles. Selection of the type of occlusion restoration considered the presence of parafunctions and the nature of the antagonistic arch. Special attention was paid to the direction and intensity of the forces acting in the region of the future prosthetic work. When bruxism was manifested, its preimplantary removal was compulsory.Results and discussion: In fixed prosthetic restaurati‐ ons applied on implants, distribuition of forces obviously depend on the quality of osteo‐acceptance, as well, and also on the elasticity degree of the prosthetic work. In the case of mobilized prosthetic restorations supported on implants, rigidization of implants from the anterior region of the mandible may be obtained by means of a bar. In decreasing order of their elasticity, the materials employed are: acrylate, composites, noble and seminoble alloys, other metals, ceramics. Ceramics confers maximum stability to implants, yet without redeeming the forces. For amortizing the forces and for a progressive charging of the implants, it is recommended that the first (temporary prosthetic restorations should be made of either acrylate or compo‐ sites.Conclusions. Observance of the occlusological princi‐ ples in cases of occlusal reconstruction represents the determining element which assures the osteo‐acceptance of implants and the integrity of prosthetic restaurations.

  20. Myoelectric control of prosthetic hands: state-of-the-art review

    Directory of Open Access Journals (Sweden)

    Geethanjali P

    2016-07-01

    Full Text Available Purushothaman Geethanjali School of Electrical Engineering Department of Control and Automation VIT University, Vellore, Tamil Nadu, India Abstract: Myoelectric signals (MES have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. Keywords: EMG, assistive device, amputee, myoelectric control, electric powered, body ­powered, bioelectric signal control

  1. Effects of a flat prosthetic foot rocker section on balance and mobility.

    Science.gov (United States)

    Hansen, Andrew; Nickel, Eric; Medvec, Joseph; Brielmaier, Steven; Pike, Alvin; Weber, Marilyn

    2014-01-01

    Previous studies have shown that the effective rocker shape of the physiologic ankle-foot system during standing and fore-aft swaying is much flatter than that used during walking, which indicates a more stable base of support for the standing/swaying activity. Previous work suggests that flat regions within the effective rocker shapes of prosthetic ankle-foot systems could provide enhanced stability for standing balance tasks. An experimental prosthetic foot was altered to provide three different flat region lengths within its effective rocker shape. It was hypothesized that longer flat regions of the effective rocker shape would lead to improved standing balance outcomes and reduced walking performance for unilateral transtibial prosthesis users. However, no significant changes were seen in the balance and mobility outcomes of 12 unilateral transtibial prosthesis users when using the three prosthetic foot conditions. Subjects in the study significantly preferred prosthetic feet with relatively low to moderate flat regions over those with long flat regions. All the subjects without loss of light touch or vibratory sensation selected the prosthetic foot with the shortest flat region. More work is needed to investigate the effects of prosthetic foot properties on balance and mobility of prosthesis users.

  2. Kamide reflects on JGR and the role of editor

    Science.gov (United States)

    Woods, Peter

    After serving the space physics community for more than 11 years, Y. Kamide of the Solar-Terrestrial Environment Laboratory at Nagoya University in Toyokawa, Japan, retired as editor of the Journal of Geophysical Research-Space Physics for the Asian/Pacific region. He had been a JGR editor since AGU first opened two editorial offices in Europe and the Asian/Pacific region in 1989. Even as the initial JGR editor in Asia, Kamide was not new to AGU editorial business. Before accepting the JGR position, Kamide served 3 years as the editor in Japan for Geophysical Research Letters.According to Kamide, over the last 5 years, the number of high-quality submissions to JGR in the Asian/Pacific region has increased dramatically, by a factor of 2.5. This increase came mostly from the younger generation of scientists, which bodes well for the future of JGR and space physics in general. Together with the substantial contributions to JGR from the European community, this achievement has been recognized by AGU as proof that JGR is truly an international journal of the highest editorial standards.

  3. A Critical Review on Prosthetic Features Available for Reversed Total Shoulder Arthroplasty

    Directory of Open Access Journals (Sweden)

    Bart Middernacht

    2016-01-01

    Full Text Available Reversed total shoulder arthroplasty is a popular treatment in rotator cuff arthropathy and in displaced proximal humeral fractures in elderly. In 2016, 29 models of commercially available designs express this popularity. This study describes all the different design parameters available on the market. Prosthetic differences are found for the baseplate, glenosphere, polyethylene, and humeral component and these differences need to be weighed out carefully for each patient knowing that a gain in one mechanical parameter can balance the loss of another. Patient specific implants may help in the future.

  4. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  5. Authors and editors assort on gender and geography in high-rank ecological publications.

    Directory of Open Access Journals (Sweden)

    Kezia R Manlove

    Full Text Available Peer-reviewed publication volume and caliber are widely-recognized proxies for academic merit, and a strong publication record is essential for academic success and advancement. However, recent work suggests that publication productivity for particular author groups may also be determined in part by implicit biases lurking in the publication pipeline. Here, we explore patterns of gender, geography, and institutional rank among authors, editorial board members, and handling editors in high-impact ecological publications during 2015 and 2016. A higher proportion of lead authors had female first names (33.9% than editorial board members (28.9%, and the proportion of female first names among handling editors was even lower (21.1%. Female editors disproportionately edited publications with female lead authors (40.3% of publications with female lead authors were handled by female editors, though female editors handled only 34.4% of all studied publications. Additionally, ecological authors and editors were overwhelmingly from countries in the G8, and high-ranking academic institutions accounted for a large portion of both the published work, and its editorship. Editors and lead authors with female names were typically affiliated with higher-ranking institutions than their male peers. This description of author and editor features provides a baseline for benchmarking future trends in the ecological publishing culture.

  6. Authors and editors assort on gender and geography in high-rank ecological publications.

    Science.gov (United States)

    Manlove, Kezia R; Belou, Rebecca M

    2018-01-01

    Peer-reviewed publication volume and caliber are widely-recognized proxies for academic merit, and a strong publication record is essential for academic success and advancement. However, recent work suggests that publication productivity for particular author groups may also be determined in part by implicit biases lurking in the publication pipeline. Here, we explore patterns of gender, geography, and institutional rank among authors, editorial board members, and handling editors in high-impact ecological publications during 2015 and 2016. A higher proportion of lead authors had female first names (33.9%) than editorial board members (28.9%), and the proportion of female first names among handling editors was even lower (21.1%). Female editors disproportionately edited publications with female lead authors (40.3% of publications with female lead authors were handled by female editors, though female editors handled only 34.4% of all studied publications). Additionally, ecological authors and editors were overwhelmingly from countries in the G8, and high-ranking academic institutions accounted for a large portion of both the published work, and its editorship. Editors and lead authors with female names were typically affiliated with higher-ranking institutions than their male peers. This description of author and editor features provides a baseline for benchmarking future trends in the ecological publishing culture.

  7. Initial Clinical Evaluation of the Modular Prosthetic Limb

    Directory of Open Access Journals (Sweden)

    Briana N. Perry

    2018-03-01

    Full Text Available The Modular Prosthetic Limb (MPL was examined for its feasibility and usability as an advanced, dexterous upper extremity prosthesis with surface electromyography (sEMG control in with two individuals with below-elbow amputations. Compared to currently marketed prostheses, the MPL has a greater number of sequential and simultaneous degrees of motion, as well as wrist modularity, haptic feedback, and individual digit control. The MPL was successfully fit to a 33-year-old with a trans-radial amputation (TR01 and a 30-year-old with a wrist disarticulation amputation (TR02. To preserve anatomical limb length, we adjusted the powered degrees of freedom of wrist motion between users. Motor training began with practicing sEMG and pattern recognition control within the virtual integration environment (VIE. Prosthetic training sessions then allowed participants to complete a variety of activities of daily living with the MPL. Training and Motion Control Accuracy scores quantified their ability to consistently train and execute unique muscle-to-motion contraction patterns. Each user also completed one prosthetic functional metric—the Southampton Hand Assessment Procedure (SHAP for TR01 and the Jebsen-Taylor Hand Function Test (JHFT for TR02. Haptic feedback capabilities were integrated for TR01. TR01 achieved 95% accuracy at 84% of his VIE sessions. He demonstrated improved scores over a year of prosthetic training sessions, ultimately achieving simultaneous control of 13 of the 17 (76% attempted motions. His performance on the SHAP improved from baseline to final assessment with an increase in number of tasks achieved. TR01 also used vibrotactile sensors to successfully discriminate between hard and soft objects being grasped by the MPL hand. TR02 demonstrated 95% accuracy at 79% of his VIE sessions. He demonstrated improved scores over months of prosthetic training sessions, however there was a significant drop in scores initially following a mid

  8. Report of the world association of medical editors: agenda for the future.

    Science.gov (United States)

    2001-04-01

    During a 3-day meeting at Bellagio in January 2001, a group of 20 editors from 12 countries in 5 continents met to map out a strategy for the World Association of Medical Editors (WAME)'s continued development in the service of medical editors over the next several years. The group: 1) Developed a statement of principles on the standards of professionalism and responsibilities of editors (this statement will be posted on the Web site after electronic consultation with and comment by WAME editors); 2) Agreed to assess the extent to which these principles are reflected in practice and to explore barriers to their adoption, using data from a survey and focus groups; 3) Developed and outlined an on-line program for distance learning, targeted at new editors; 4) Planned for formal evaluation of the educational outreach program; and 5) Agreed to support regional initiatives to strengthen local editorial capacity. Underpinning all past and proposed future activities is the WAME Web site. The ambitious plans outlined above will require extensive development of the site, plans for which were made at the Bellagio meeting.

  9. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  10. How Managing Editors View and Deal with Newspaper Ethical Issues.

    Science.gov (United States)

    Anderson, Douglas

    1987-01-01

    Claims there is awareness and concern about journalism ethics among daily newspaper managing editors. Asserts that although ethical issues are being addressed to some degree, greater efforts could be made to see that reporters and editors are apprised of codes of ethics. (MM)

  11. Control system and method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  12. Editorial: Letter from the Editors

    Directory of Open Access Journals (Sweden)

    Wilhelm Heitmeyer

    2011-12-01

    Full Text Available This issue our guest editors are close to home. Wilhelm Heitmeyer and Steven F. Messner, both members of our own Board of Editors, have assembled a focus section examining the question of “Youth at Risk.” Their collection certainly lives up to our aspiration to be truly interdisciplinary and international. The methods applied in the reported research range from interview-based studies through empirical number-crunching to laboratory experiments (the latter a first for this journal; the geographical scope spans from Argentina through Central America and Europe to Africa. The youth at risk here are in conflict with the police, with each other, with societies that fear them, with societies that ignore their needs. Our systematically eclectic approach continues outside the focus section too, with contributions on the theory of violence, female fighters in Africa, and spousal violence in Pakistan.

  13. A computational method for comparing the behavior and possible failure of prosthetic implants

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, C.; Hollerbach, K.; Perfect, S.; Underhill, K.

    1995-05-01

    Prosthetic joint implants currently in use exhibit high Realistic computer modeling of prosthetic implants provides an opportunity for orthopedic biomechanics researchers and physicians to understand possible in vivo failure modes, without having to resort to lengthy and costly clinical trials. The research presented here is part of a larger effort to develop realistic models of implanted joint prostheses. The example used here is the thumb carpo-metacarpal (cmc) joint. The work, however, can be applied to any other human joints for which prosthetic implants have been designed. Preliminary results of prosthetic joint loading, without surrounding human tissue (i.e., simulating conditions under which the prosthetic joint has not yet been implanted into the human joint), are presented, based on a three-dimensional, nonlinear finite element analysis of three different joint implant designs.

  14. Developing Visual Editors for High-Resolution Haptic Patterns

    DEFF Research Database (Denmark)

    Cuartielles, David; Göransson, Andreas; Olsson, Tony

    2012-01-01

    In this article we give an overview of our iterative work in developing visual editors for creating high resolution haptic patterns to be used in wearable, haptic feedback devices. During the past four years we have found the need to address the question of how to represent, construct and edit high...... resolution haptic patterns so that they translate naturally to the user’s haptic experience. To solve this question we have developed and tested several visual editors...

  15. Letters to the Editor

    Science.gov (United States)

    1999-09-01

    All the Letters to the Editor in this issue are in the same PostScript or PDF file. Contents The imaginary Sun? Harold Aspden Energy Science Ltd, PO Box 35, Southampton SO16 7RB, UK Difficult physics? Tim Akrill Chief Examiner, A-level Physics, Edexcel Foundation Was it a dream? Bill Jarvis 6 Peggy's Mill Road, Edinburgh EH4 6JY

  16. Letter from the Editors

    Directory of Open Access Journals (Sweden)

    Paul Boshears

    2012-08-01

    Full Text Available With grateful hearts we offer this, the second issue of our second volume. The result of months of back-breaking thinking, emailing, looking, clicking, watching, writing and reading, our summer issue is here. The editors could not have done this without your support. We welcome your materials for our future issues as well as your continued contributions.

  17. Letter from the Editors

    Directory of Open Access Journals (Sweden)

    The Editors

    2013-07-01

    Full Text Available With grateful hearts we offer this, the first issue of our third volume. The result of months of back-breaking thinking, emailing, looking, clicking, watching, writing and reading, our new issue is here. The editors could not have done this without your support. We welcome your materials for our future issues as well as your continued contributions.

  18. Letter from the Editors

    Directory of Open Access Journals (Sweden)

    Paul Boshears

    2012-11-01

    Full Text Available With grateful hearts we offer this, the third issue of our second volume. The result of months of back-breaking thinking, emailing, looking, clicking, watching, writing and reading, our fall issue is here. The editors could not have done this without your support. We welcome your materials for our future issues as well as your continued contributions.

  19. Gonococcal Prosthetic Joint Infection.

    Science.gov (United States)

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  20. Rehand: Realistic electric prosthetic hand created with a 3D printer.

    Science.gov (United States)

    Yoshikawa, Masahiro; Sato, Ryo; Higashihara, Takanori; Ogasawara, Tsukasa; Kawashima, Noritaka

    2015-01-01

    Myoelectric prosthetic hands provide an appearance with five fingers and a grasping function to forearm amputees. However, they have problems in weight, appearance, and cost. This paper reports on the Rehand, a realistic electric prosthetic hand created with a 3D printer. It provides a realistic appearance that is same as the cosmetic prosthetic hand and a grasping function. A simple link mechanism with one linear actuator for grasping and 3D printed parts achieve low cost, light weight, and ease of maintenance. An operating system based on a distance sensor provides a natural operability equivalent to the myoelectric control system. A supporter socket allows them to wear the prosthetic hand easily. An evaluation using the Southampton Hand Assessment Procedure (SHAP) demonstrated that an amputee was able to operate various objects and do everyday activities with the Rehand.

  1. U.S. EPA Metadata Editor (EME)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Metadata Editor (EME) allows users to create geospatial metadata that meets EPA's requirements. The tool has been developed as a desktop application that...

  2. Predicting Post-Editor Profiles from the Translation Process

    DEFF Research Database (Denmark)

    Singla, Karan; Orrego-Carmona, David; Gonzales, Ashleigh Rhea

    2014-01-01

    The purpose of the current investigation is to predict post-editor profiles based on user behaviour and demographics using machine learning techniques to gain a better understanding of post-editor styles. Our study extracts process unit features from the CasMaCat LS14 database from the CRITT...... of translation process features. The classification and clustering of participants resulting from our study suggest this type of exploration could be used as a tool to develop new translation tool features or customization possibilities....

  3. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  4. Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles.

    Science.gov (United States)

    Peel, Trisha N; Dylla, Brenda L; Hughes, John G; Lynch, David T; Greenwood-Quaintance, Kerryl E; Cheng, Allen C; Mandrekar, Jayawant N; Patel, Robin

    2016-01-05

    Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media (P Prosthetic joint infections are a devastating complication of arthroplasty surgery. Despite this, current microbiological techniques to detect and diagnose infections are imperfect. This study examined a new approach to diagnosing infections, through the inoculation of tissue samples from around the prosthetic joint into blood culture bottles. This study demonstrated that, compared to current laboratory practices, this new technique increased the detection of infection. These findings are important for patient care to allow timely and accurate diagnosis of infection. Copyright © 2016 Peel et al.

  5. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    Science.gov (United States)

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  6. Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations.

    Science.gov (United States)

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-04-01

    Inspired by the springlike action of biological legs, running-specific prostheses are designed to enable athletes with lower-limb amputations to run. However, manufacturer's recommendations for prosthetic stiffness and height may not optimize running performance. Therefore, we investigated the effects of using different prosthetic configurations on the metabolic cost and biomechanics of running. Five athletes with bilateral transtibial amputations each performed 15 trials on a force-measuring treadmill at 2.5 or 3.0 m/s. Athletes ran using each of 3 different prosthetic models (Freedom Innovations Catapult FX6, Össur Flex-Run, and Ottobock 1E90 Sprinter) with 5 combinations of stiffness categories (manufacturer's recommended and ± 1) and heights (International Paralympic Committee's maximum competition height and ± 2 cm) while we measured metabolic rates and ground reaction forces. Overall, prosthetic stiffness [fixed effect (β) = 0.036; P = 0.008] but not height ( P ≥ 0.089) affected the net metabolic cost of transport; less stiff prostheses reduced metabolic cost. While controlling for prosthetic stiffness (in kilonewtons per meter), using the Flex-Run (β = -0.139; P = 0.044) and 1E90 Sprinter prostheses (β = -0.176; P = 0.009) reduced net metabolic costs by 4.3-4.9% compared with using the Catapult prostheses. The metabolic cost of running improved when athletes used prosthetic configurations that decreased peak horizontal braking ground reaction forces (β = 2.786; P = 0.001), stride frequencies (β = 0.911; P < 0.001), and leg stiffness values (β = 0.053; P = 0.009). Remarkably, athletes did not maintain overall leg stiffness across prosthetic stiffness conditions. Rather, the in-series prosthetic stiffness governed overall leg stiffness. The metabolic cost of running in athletes with bilateral transtibial amputations is influenced by prosthetic model and stiffness but not height. NEW & NOTEWORTHY We measured the

  7. Editor de la revista: entre el sueño y la supervivencia

    Directory of Open Access Journals (Sweden)

    Maria das Graças TARGINO

    2015-05-01

    Full Text Available Analiza el papel del editor científico, relaciona las habilidades necesarias para aquellos que anhelan ser editor y reanuda las funciones que él realiza en una revista científica. Revisa los conceptos clave, como editor y editora, edición y proceso editorial. Recuerda la tipología de las editoras, y, sobre todo, muestra que el editor vive la paradoja de responder a las cuestiones culturales del país en que vive (el sueño y asegurar las ganancias por los libros que publica (la supervivencia. Describe el mercado editorial brasileño de las publicaciones científicas, en referencia a los títulos impresos y electrónicos. Destaca la mediación entre el autor y el editor y los dilemas inherentes a la función de generar la producción intelectual (de cualquier naturaleza; la mercantilización creciente de la producción intelectual y científica como producto comercial; la multiplicidad de funciones que la cotidianidad impone al editor; la cuestión cantidad versus calidad de los originales enviados a las revistas científicas. Por último, destaca la importancia del editor de revistas científicas, que garantiza la seguridad, la calidad y el reconocimiento de los títulos publicados y, por lo tanto, de la comunicación científica mediante el cuidado con la calidad de los trabajos científicos.

  8. Editor de la revista: entre el sueño y la supervivencia

    Directory of Open Access Journals (Sweden)

    Maria das Graças TARGINO

    2014-07-01

    Full Text Available Analiza el papel del editor científico, relaciona las habilidades necesarias para aquellos que anhelan ser editor y reanuda las funciones que él realiza en una revista científica. Revisa los conceptos clave, como editor y editora, edición y proceso editorial. Recuerda la tipología de las editoras, y, sobre todo, muestra que el editor vive la paradoja de responder a las cuestiones culturales del país en que vive (el sueño y asegurar las ganancias por los libros que publica (la supervivencia. Describe el mercado editorial brasileño de las publicaciones científicas, en referencia a los títulos impresos y electrónicos. Destaca la mediación entre el autor y el editor y los dilemas inherentes a la función de generar la producción intelectual (de cualquier naturaleza; la mercantilización creciente de la producción intelectual y científica como producto comercial; la multiplicidad de funciones que la cotidianidad impone al editor; la cuestión cantidad versus calidad de los originales enviados a las revistas científicas. Por último, destaca la importancia del editor de revistas científicas, que garantiza la seguridad, la calidad y el reconocimiento de los títulos publicados y, por lo tanto, de la comunicación científica mediante el cuidado con la calidad de los trabajos científicos.

  9. Psychometric evaluation of self-report outcome measures for prosthetic applications.

    Science.gov (United States)

    Hafner, Brian J; Morgan, Sara J; Askew, Robert L; Salem, Rana

    2016-01-01

    Documentation of clinical outcomes is increasingly expected in delivery of prosthetic services and devices. However, many outcome measures suitable for use in clinical care and research have not been psychometrically tested with prosthesis users. The aim of this study was to determine test-retest reliability, mode-of-administration (MoA) equivalence, standard error of measurement (SEM), and minimal detectable change (MDC) of standardized, self-report instruments that assess constructs of importance to people with lower limb loss. Prosthesis users (n = 201) were randomly assigned to groups based on MoA (i.e., paper, electronic, or mixed-mode). Participants completed two surveys 2 to 3 d apart. Instruments included the Prosthetic Limb Users Survey of Mobility, Prosthesis Evaluation Questionnaire-Mobility Subscale, Activities-Specific Balance Confidence Scale, Quality of Life in Neurological Conditions-Applied Cognition/General Concerns, Patient-Reported Outcomes Measurement Information System Profile, and Socket Comfort Score. Intraclass correlation coefficients indicated all instruments are appropriate for group-level comparisons and select instruments are suitable for individual-level applications. Several instruments showed evidence of possible floor and ceiling effects. All were equivalent across MoAs. SEM and MDC were quantified to facilitate interpretation of outcomes and change scores. These results can enhance clinicians' and researchers' ability to select, apply, and interpret scores from instruments administered to prosthesis users.

  10. Prosthetic joint infection development of an evidence-based diagnostic algorithm.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Pohlig, Florian; Kanz, Karl-Georg; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; Kelch, Sarah; Harrasser, Norbert; von Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes

    2017-03-09

    Increasing rates of prosthetic joint infection (PJI) have presented challenges for general practitioners, orthopedic surgeons and the health care system in the recent years. The diagnosis of PJI is complex; multiple diagnostic tools are used in the attempt to correctly diagnose PJI. Evidence-based algorithms can help to identify PJI using standardized diagnostic steps. We reviewed relevant publications between 1990 and 2015 using a systematic literature search in MEDLINE and PUBMED. The selected search results were then classified into levels of evidence. The keywords were prosthetic joint infection, biofilm, diagnosis, sonication, antibiotic treatment, implant-associated infection, Staph. aureus, rifampicin, implant retention, pcr, maldi-tof, serology, synovial fluid, c-reactive protein level, total hip arthroplasty (THA), total knee arthroplasty (TKA) and combinations of these terms. From an initial 768 publications, 156 publications were stringently reviewed. Publications with class I-III recommendations (EAST) were considered. We developed an algorithm for the diagnostic approach to display the complex diagnosis of PJI in a clear and logically structured process according to ISO 5807. The evidence-based standardized algorithm combines modern clinical requirements and evidence-based treatment principles. The algorithm provides a detailed transparent standard operating procedure (SOP) for diagnosing PJI. Thus, consistently high, examiner-independent process quality is assured to meet the demands of modern quality management in PJI diagnosis.

  11. Clinical Effectiveness of Using Aesthetic Fixed Prosthetic Appliances with Combined Occlusal Surface

    OpenAIRE

    Andrii Biben; Zinovii Ozhohan

    2017-01-01

    The objective of the research was to evaluate the clinical effectiveness of using aesthetic fixed prosthetic appliances with combined occlusal surface. Materials and methods. The study included 30 patients who were divided into 2 groups: Group I included 20 patients with combined occlusal surface of the crowns; Group II included 22 patients with ceramic occlusal surface of the crowns. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. 6 months after prosthet...

  12. Greetings from the Editor

    Directory of Open Access Journals (Sweden)

    Mohammad Hosein Ebrahimzadeh

    2014-09-01

    , Prof. Pietro Ruggieri from Rissuli Insitiu, Bleona, Italy, Prof. Javad Parvizi from Rothman Institute at Thomas Jefferson University, Philadelphia, Prof. Mudgal from Harvard University, Boston, MA, and Prof Reinhard Graf from Allgemeines und Orthopädisches LKH Stolzalpe, Austria and Prfo. Hadi Makhmalbaf from Mashhad University of Medical Sciences, Mashhad, Iran (1-6. Iranian literature in orthopedics goes back to the time of Razi (Rhazes, who was the first to design guidelines for diagnosis and treatment of the osteoarticular tuberculosis, diagnosis and managemet of fractures and dislocations (7. We, as Iranian Orthopedic Community, have a long way to run to reach to the level of becoming a global reference in medicine over the 21st century. Finally I wish this journal could build a network of clinical orthopedic scientists, biomedical orthopedic scientists, and orthopedic societies to join and share their ideas, evidences, techniques and results for a better care of orthopedic patients around the world. This collaboration will melt the ice that may have surrounded the human community, to understand more about each others and to help as much as possible. Stated by Prof. Jesse Jupiter in his Editoral for inauguration of ABJS “I am very confident that this Journal will permit others to have a window into the advances being made by Iranian Orthopedic surgeons as well as providing a platform for others to contribute their own knowledge and ideas. In a small way, this Journal will serve to continue efforts to expand our global Orthopedic Surgical community and serve to stimulate our political leaders to do likewise.”(1.

  13. From The Editor

    OpenAIRE

    Ugur Demiray

    2013-01-01

    Dear TOJDE Readers, Welcome to the Volume 14 Number: 1 of TOJDE! In this issue, 31 articles of 65 authors from 12 different countries around the world have been published. These published articles are arrived to the TOJDE from Australia, Guyana, India, Indonesia, Iran, Malaysia, Nigeria, Russia, Taiwan, Turkey, USA and Zimba bwe. First all, you should know that if a submission picks up from three TOJDE editors between 4.5 and 9 over all 9 credits, it means that this submission can be publish...

  14. From the Editor

    OpenAIRE

    Ugur Demiray

    2009-01-01

    Greetings Dear readers of TOJDE,TOJDE is appeared on your screen now as Volume 10, Number: 4. This is the last issue of the year 2009 and 10th anniversary of TOJDE. In this issue it is published 3 notes for Editor, 13 articles, 4 book reviews. And this time, 33 authors from 13 different countries are placed. These published articles are from Bangladesh, Egypt, India, Iran, KKTC, Lesotho, Lithuania, Malaysia, Pakistan, Romania, United Kingdom, USA and Turkey.“iPhones and Smartphones” has sent ...

  15. Clinical Presentation, Risk Factors, and Outcomes of Hematogenous Prosthetic Joint Infection in Patients with Staphylococcus aureus Bacteremia.

    Science.gov (United States)

    Tande, Aaron J; Palraj, Bharath Raj; Osmon, Douglas R; Berbari, Elie F; Baddour, Larry M; Lohse, Christine M; Steckelberg, James M; Wilson, Walter R; Sohail, M Rizwan

    2016-02-01

    Staphylococcus aureus bacteremia is a life-threatening condition that may lead to metastatic infection, including prosthetic joint infection. To assess clinical factors associated with hematogenous prosthetic joint infection, we retrospectively reviewed all patients with a joint arthroplasty in place at the time of a first episode of S. aureus bacteremia over a 5-year period at our institution. Patients with postsurgical prosthetic joint infection without hematogenous prosthetic joint infection were excluded. There were 85 patients (143 arthroplasties) with either no prosthetic joint infection (n = 50; 58.8%) or hematogenous prosthetic joint infection in at least one arthroplasty (n = 35; 41.2%). The odds of hematogenous prosthetic joint infection was significantly increased among patients with community-acquired S. aureus bacteremia (odds ratio [OR] 18.07; 95% confidence interval [CI] 2.64-infinity; P = .001), as compared with nosocomial S. aureus bacteremia, in which there were no patients with hematogenous prosthetic joint infection. After adjusting for S. aureus bacteremia classification, the presence of ≥3 joint arthroplasties in place was associated with a nearly ninefold increased odds of hematogenous prosthetic joint infection as compared with those with 1-2 joint arthroplasties in place (OR 8.55; 95% CI 1.44-95.71; P = .012). All but one joint with prosthetic joint infection demonstrated at least one clinical feature suggestive of infection. There were 4 additional S. aureus prosthetic joint infections diagnosed during a median of 3.4 years of follow-up post hospitalization for S. aureus bacteremia. Prosthetic joint infection is frequent in patients with existing arthroplasties and concomitant S. aureus bacteremia, particularly with community-acquired S. aureus bacteremia and multiple prostheses. In contrast, occult S. aureus prosthetic joint infection without clinical features suggestive of prosthetic joint infection at the time of S. aureus bacteremia

  16. Clinical characteristics, microbiology, and outcomes of prosthetic joint infection in Taiwan.

    Science.gov (United States)

    Tsai, Jen-Chih; Sheng, Wang-Huei; Lo, Wan-Yu; Jiang, Ching-Chuan; Chang, Shan-Chwen

    2015-04-01

    Prosthetic joint infection (PJI) after total knee or hip replacement is a devastating complication associated with substantial morbidity and economic cost. The incidence of prosthetic joint infection is increasing as the use of mechanical joint replacement increases. The treatment approach to prosthetic joint infection is based on different clinical situations such as a patient's comorbidities, epidemic microbiology data, and surgical procedures. The aim of our study was to understand clinical characteristics of prosthetic joint infection, the microbiology of the prosthetic joint infection, and the outcomes of different treatment strategies during 2006-2011. We retrospectively collected cases of prosthetic joint infection in the National Taiwan University Hospital between January 1, 2006 and December 31, 2011. The patients' characteristics, microbiology, outcomes, and factors associated with treatment success were recorded. One hundred and forty-four patients were identified as having PJI. Of these, 92 patients were entered into per-protocol analysis. Staphylococcus aureus was the most common causative organism (29.9%), followed by coagulase-negative Staphylococci (16.7%), and Enterococci (9.7%). The overall treatment success rate was 50%. Patients who received a two-stage revision had a better outcome, compared to patients who underwent other types of surgeries (70% vs. 32.7%, respectively; p < 0.001). In multivariate analysis, the two-stage revision was significantly associated with treatment success (odds ratio = 3.923, 95% confidence interval = 1.53-10.04). Our study demonstrates that Staphylococcus aureus was the most common causative organisms in PJI. Performing two-stage revisions was significantly associated with a better outcome. Copyright © 2013. Published by Elsevier B.V.

  17. EDITORIAL: Editorial from the new Editor-in-Chief for 2014 Editorial from the new Editor-in-Chief for 2014

    Science.gov (United States)

    Graham, W. G.

    2014-02-01

    I am honoured to take on the leadership of Plasma Sources Science and Technology (PSST) as the successor to Professor Mark J Kushner, with whom I have had the pleasure to work on the journal for many years. Under Mark's insightful and energetic leadership over the last six years, PSST has cemented its position as the journal of choice within its subject area and is now one of the most successful journals in the field. In this first issue of 2014, I would like to reflect on some of the events and achievements of 2013. At the start of the year the PSST Editorial Board, recognizing the vital importance of atomic, molecular and optical (AMO) data to low-temperature plasma physics, agreed that PSST would accept papers reporting such new data, generated through both experiment and theory. Jonathan Tennyson joined the Editorial Board to represent this area. In March Anne Bourdon joined the Associate Editor team and has since then played a key part in the journal's review process alongside our other Editors. During the autumn, PSST moved to a new editorial management system. In December Deborah O'Connell was awarded the 2013 Hershkowitz Early Career Award and Review and joins the Editorial Board as of 2014. I would also like to thank Miles Turner for his work in leading the drafting of a guide on the details necessary in the reporting of the results of computer simulations; the main conclusions of this report have been incorporated into the journal policy. Overall 2013 has been another successful year for PSST; paper submissions were up by 8% on the previous year and there was the highest ever number of downloads of PSST papers in one year. Another noteworthy feature of 2013 was the continuing improvement in publication times while maintaining our high standards for acceptance and providing expert feedback coupled with encouragement particularly to younger researchers and groups. Largely as a result of the hard work of our referees and Associate Editors, the average time

  18. New developments in prosthetic arm systems

    Directory of Open Access Journals (Sweden)

    Vujaklija I

    2016-07-01

    Full Text Available Ivan Vujaklija,1 Dario Farina,1 Oskar C Aszmann2 1Institute of Neurorehabilitation Systems, Bernstein Focus Neurotechnology Göttingen, University Medical Center Göttingen, Georg-August University, Göttingen, Germany; 2Christian Doppler Laboratory for Restoration of Extremity Function, Division of Plastic and Reconstructive Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria Abstract: Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb

  19. A mechanism to compensate undesired stiffness in joints of prosthetic hands

    NARCIS (Netherlands)

    Smit, G.; Plettenbrug, D.H.; Van der Helm, F.C.T.

    2014-01-01

    Background: Cosmetic gloves that cover a prosthetic hand have a parasitic positive stiffness that counteracts the flexion of a finger joint. Objectives: Reducing the required input torque to move a finger of a prosthetic hand by compensating the parasitic stiffness of the cosmetic glove. Study

  20. The Introductory Psychology Textbook Market: Perceptions of Authors and Editors.

    Science.gov (United States)

    Griggs, Richard A.; Jackson, Sherri L.

    1989-01-01

    Surveys psychology textbook authors and editors on their perceptions of the introductory psychology textbook market. Finds that the textbook market is divided into three levels according to quality, and that authors and editors are not familiar with most textbooks. Notes that the growth of used book companies has adversely affected the market.…

  1. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    Science.gov (United States)

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  2. From the Editors

    Directory of Open Access Journals (Sweden)

    Sibel Sakarya

    2017-09-01

    Full Text Available From the Editors Dear readers,We are happy to greet you with the August 2017 issue of our Journal. This issue contains two reports and five original articles. The title of the first report is “Roma Health in Edirne: Social Determinants of Health and Health Status”. In their report, Eskiocak et al. investigate the social determinants of health and their health related outcomes among the Roma communities living in Edirne. The second report deals with gender related issues. Doğan et al. investigate the effects of gender inequality on women's lives through a comparison of countries that do and do not implement policies based on gender equality.Original articles in this issue cover many important public health issues. The first, conducted by Koçak et al., investigates the type 2 diabetes risk of primary school teachers and their lifestyle behaviors. Results of the study show that 5.7% out of 975 primary school teachers have a high risk of type 2 diabetes.The second original article entitled “Unintended pregnancies, induced abortions and risk factors in women admitted to hospitals due to birth or abortion in Hatay” was based on a study of 635 women. The results of this study, done by Savaş et al., show an unintended pregnancy rate of 15%. It is further estimated that almost half of all induced abortions are reported as spontaneous abortions. The third article, which was written by Çam et al., is about the frequency of eating disorders in adolescents. This descriptive study, with the participation of 338 high school students, found the frequency of eating disorder attitudes to be 18.3% among the participants. In a descriptive study conducted by Emerce et al., the knowledge and practice of laboratory safety by laboratory analysts and technicians was investigated. It was found that all 93 laboratory workers who participated in the study have failed in some safety practices throughout their careers, and have been eager to get regular

  3. Analysis of the results of the first implementation of the Korea Manuscript Editors Certification

    Directory of Open Access Journals (Sweden)

    Hyun Jung Yi

    2017-02-01

    Full Text Available In the field of international scholarly journal publishing, manuscript editing has been established as an essential component of the publication process. As the necessity of this process has increased, the Korean Council of Science Editors has consistently provided education for training professional manuscript editors, and has worked to implement a manuscript editor certification system. Starting in 2014, the Korean Council of Science Editors thoroughly conducted background research and advanced analysis in preparation for such a system. Subsequently, a committee of experts was formed to develop and simulate an examination for this certification. This process culminated in the first manuscript editor certification examination, which was held in November 2016 and resulted in 40 initial Korea Manuscript Editors Certification holders. Examinations for the Korea Manuscript Editors Certification are scheduled to be held annually. The establishment of this certification system will contribute to strengthening individual capacities and further developing science journal publication in Korea by expanding the field of manuscript editing. Ultimately, this system will contribute to the promotion of Korean scientific journals to the level of prominent international journals.

  4. [Tuberculous prosthetic knee joint infection: a case report and literature review].

    Science.gov (United States)

    Lara-Oya, A; Liébana-Martos, M C; Rodríguez-Granger, J; Sampedro-Martínez, A; Aliaga-Martínez, L; Gutierrez-Fernández, J; Navarro-Marí, J M

    2016-08-01

    Prosthetic late infection occurs in the second month after surgery in the context of haematogenous spread from another source. Prosthetic mycobacterial infection is a rare complication whose clinical management is not standardized. Patient of 77 years with no personal history except for diabetes and a prosthetic replacement of right knee with osteoarthritis three years ago. Patient goes to hospital emergency box for 6 months pain in the right knee with mechanical inflammatory signs but no fever associated. After their return within 5 days and clinical worsening is reporting growth of Mycobacterium tuberculosis in knee aspirate and antitubercular treatment is established for 9 months. Nuclear magnetic resonance imaging studies also confirmed the diagnosis of tuberculosis spondylitis in the clinical context of the patients. After surgery, M. tuberculosis was again isolated from intraoperative samples and therefore the patient received another batch of treatment for 9 months. After a year of monitoring, the development was acceptable but few months later, the patient died for cardiovascular causes. In the literature review, 15 publications with a total of 17 clinical cases of prosthetic infection by M. tuberculosis were found from 1980 to 2014. Prosthetic tuberculous arthritis, although it is a rare presentation, it should be noted, especially in patients with predisposing conditions with a history of tuberculosis infection.

  5. Expectations of an editor in case of an incident

    International Nuclear Information System (INIS)

    Widmer, H.P.

    1997-01-01

    Our major expectations about information of nuclear power station operators are: Truthfulness, comprehensibility, availability and editor's disposal when needed. The information must be clear and true. It has to give an account of the complex facts in which laymen readers fully understand. Editors rely on scientific support and the spokespersons' tolerance for media specific particularities; such as, competition, to be first in information, and time pressure. (orig.) [de

  6. Greetings from the new Editor-in-Chief, Ronald Stambaugh Greetings from the new Editor-in-Chief, Ronald Stambaugh

    Science.gov (United States)

    Stambaugh, Ronald

    2012-04-01

    I am very pleased to join the outstanding leadership team for the journal Nuclear Fusion as Scientific Editor. The journal's high position in the field of fusion energy research derives in no small measure from the efforts of the IAEA team in Vienna, the production and marketing of IOP Publishing, the Board of Editors led by its chairman Mitsuru Kikuchi, the Associate Editor for Inertial Confinement Max Tabak and the outgoing Scientific Editor, Paul Thomas. During Paul's five year tenure submissions have grown by over 40%. The usage of the electronic journal has grown year by year with about 300 000 full text downloads of Nuclear Fusion articles in 2011, an impressive figure due in part to the launch of the full 50 year archive. High quality has been maintained while times for peer review and publishing have been reduced and the journal achieved some of the highest impact factors ever (as high as 4.27). The journal has contributed greatly to building the international scientific basis for fusion. I was privileged to serve from 2003 to 2010 as chairman of the Coordinating Committee for the International Tokamak Physics Activity (ITPA) which published in Nuclear Fusion the first ITER Physics Basis (1999) and its later update (2007). The scientific basis that has been developed to date for fusion has led to the construction of major facilities to demonstrate the production of power-plant relevant levels of fusion reactions. We look forward to the journal continuing to play a key role in the international effort toward fusion energy as these exciting major facilities and the various approaches to fusion continue to be developed. It is clear that Nuclear Fusion maintains its position in the field because of the perceived high quality of the submissions, the refereeing and the editorial processes, and the availability and utility of the online journal. The creation of the Nuclear Fusion Prize, led by the Board of Editors chairman Mitsuru Kikuchi, for the most outstanding

  7. Control of a powered prosthetic device via a pinch gesture interface

    Science.gov (United States)

    Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.

    2015-06-01

    A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.

  8. From the Editor

    OpenAIRE

    Ugur Demiray

    2006-01-01

    Greetings Dear readers of TOJDE, I am pleased to inform you that in the 7th year of TOJDE is appeared on your screen now as Volume 7, Number: 3. Very much thanks to all of you once more that we met with you 23rd time, since January 2000. In this issue we published one notes for Editor 15 articles like in this issue, three book reviews, news and announcements for our readers. 25 authors from eight different countries are pleaced in this issue. These published articles are from...

  9. From the Editor

    OpenAIRE

    Ugur Demiray

    2006-01-01

    Greetings Dear readers of TOJDE, I am pleased to inform you that in the 7th year of TOJDE is appeared on your screen now as Volume 7, Number: 4. Very much thanks to all of you and TOJDE editorial members once more that we managed to publish TOJDE 25th time, since January 2000. In this issue we published one notes for Editor, 13 articles, two reviews, news and announcements for our readers. 20 authors from seven different countries are placed in this issue. These published articles are from Ba...

  10. Core competencies for scientific editors of biomedical journals: consensus statement.

    Science.gov (United States)

    Moher, David; Galipeau, James; Alam, Sabina; Barbour, Virginia; Bartolomeos, Kidist; Baskin, Patricia; Bell-Syer, Sally; Cobey, Kelly D; Chan, Leighton; Clark, Jocalyn; Deeks, Jonathan; Flanagin, Annette; Garner, Paul; Glenny, Anne-Marie; Groves, Trish; Gurusamy, Kurinchi; Habibzadeh, Farrokh; Jewell-Thomas, Stefanie; Kelsall, Diane; Lapeña, José Florencio; MacLehose, Harriet; Marusic, Ana; McKenzie, Joanne E; Shah, Jay; Shamseer, Larissa; Straus, Sharon; Tugwell, Peter; Wager, Elizabeth; Winker, Margaret; Zhaori, Getu

    2017-09-11

    Scientific editors are responsible for deciding which articles to publish in their journals. However, we have not found documentation of their required knowledge, skills, and characteristics, or the existence of any formal core competencies for this role. We describe the development of a minimum set of core competencies for scientific editors of biomedical journals. The 14 key core competencies are divided into three major areas, and each competency has a list of associated elements or descriptions of more specific knowledge, skills, and characteristics that contribute to its fulfillment. We believe that these core competencies are a baseline of the knowledge, skills, and characteristics needed to perform competently the duties of a scientific editor at a biomedical journal.

  11. Prosthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases

    Directory of Open Access Journals (Sweden)

    Wada Yuko

    2011-10-01

    Full Text Available Abstract Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal

  12. Letter from the Editors

    Directory of Open Access Journals (Sweden)

    Jamie Allen

    2013-05-01

    Full Text Available With grateful hearts we offer this, the fourth issue of our second volume. The result of months of back-breaking thinking, emailing, looking, clicking, watching, writing and reading, our winter issue is here. The editors could not have done this without your support. We welcome your materials for our future issues as well as your continued contributions. Purchase your copy of our first book from Punctum Books.

  13. LOW-MOLECULAR-WEIGHT HEPARIN TREATMENT FAILURE IN PREVENTION OF PROSTHETIC MITRAL VALVE THROMBOSIS

    OpenAIRE

    David Šuran; Vojko Kanič; Tatjana Golob Gulič; Husam Franjo Naji; Robert Lipovec

    2009-01-01

    Background Prosthetic heart valve thrombosis (PHVT) represents a dangerous postoperative complication following prosthetic heart valve replacement. Incidence varies according to different data from 0.5–4 % per year following mitral or aortic valve replacement in spite of adequate oral anticoagulation with coumarins. Case report We are presenting a case of prosthetic mitral valve thrombosis as a result of 6-month lowmolecular-weight heparin (LMWH) (nadroparine) treatment failure. Our pat...

  14. Obtention of a prosthetic group for labelling of radioiodinated proteins

    International Nuclear Information System (INIS)

    Santos, Josefina da S.; Colturato, Maria Tereza; Araujo, Elaine B. de

    2000-01-01

    Antibodies and peptides labeled with radionuclides has been extensively used in radioimmunotherapy and radioimmunodetection. The principal problem with the use of radioiodinated proteins is the in vivo dehalogenation. The use of prosthetic groups for indirect labeling of proteins with radioiodine has showed to be useful on labeling proteins with greater in vivo stability. A procedure is described for the preparation of an radioiodinated prosthetic group (N-succinimidyl 4-radioiodine-benzoate-SIB), using procedure described by Stocklin et al, with the iodination of p-bromo-benzoic acid and subsequent reaction with TSTU. Preliminary labeling results showed that the prosthetic group can be obtained in a good yield. The coupling of the SIB to the protein will be studied using human IgG as protein model. (author)

  15. Prosthetic design directives: Low-cost hands within reach.

    Science.gov (United States)

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  16. A clinical survey about commercial games in lower limb prosthetic rehabilitation.

    Science.gov (United States)

    Imam, Bita; Miller, William C; Finlayson, Heather C; Eng, Janice J; Jarus, Tal

    2018-06-01

    Despite the popularity of commercial games in lower limb prosthetic rehabilitation, data about their prevalence of use as well as therapists' perspectives about these games are still lacking. To learn about the prevalence of use of commercial games in lower limb prosthetic rehabilitation and therapists' perspectives about these games. Cross-sectional. An online survey was sent to physical and occupational therapists across prosthetic rehabilitation facilities in Canada. The survey had questions about the use of commercial games and therapists' perspectives. Data were collected from 82 therapists. Overall, 46.3% (38/82) reported that they use commercial games; of those, 94.7% (36/38) used the Nintendo Wii Fit. The most reported perceived benefits were the Wii Fit helping to improve weight shifting ( n = 76/82, 92.7%) and balance ( n = 75/82, 91.5%), and being motivating and complementing traditional therapy ( n = 75/82, 91.5%). The most reported perceived barriers/challenges were lack of time and familiarity with the games ( n = 58/82, 70.7%). Commercial games, particularly the Wii Fit, are commonly used in lower prosthetic rehabilitation in Canada. Most of the queried therapists view the Wii Fit positively. Knowledge translation activities and developing standard treatment protocols would be helpful in minimizing the barriers identified in this study. Clinical relevance The Wii Fit is prevalent in lower limb prosthetic rehabilitation in Canada and it is viewed positively by therapists as having the potential to improve balance and weight bearing, making rehabilitation more motivating, and complementing traditional therapy. Future studies should investigate the efficacy of the Wii Fit in prosthetic rehabilitation.

  17. Quality Assessment of Prosthetic Rehabilitation Using Aesthetic Fixed Restorations

    Directory of Open Access Journals (Sweden)

    Zinovii Ozhohan

    2018-04-01

    Full Text Available The objective of the research was to study and assess the quality of prosthetic treatment using aesthetic fixed restorations. Materials and methods. The study included 79 patients without a comorbidity who underwent prosthetic rehabilitation. All the patients were divided into 3 groups: Group I included 25 patients with metal-plastic restorations; Group II comprised 34 patients with porcelain-fused-to-metal restorations; Group III consisted of 20 patients with a combined occlusal surface of prosthetic restorations. The patients were observed 6 months after prosthetic repair. Only patients with single molar and premolar crowns were examined. Bridge prostheses were not taken into account in order to eliminate the effect of masticatory force redistribution on the abutment crowns. Results. In Group I, 11 (44% patients were satisfied with the results of prosthetic treatment. In Group II, 25 (78.12% patients reported that they were satisfied with their treatment. In Group III, there were 17 (85% patients satisfied with their outcome. However, the patients’ complaints are often subjective and do not fully reflect the objective state of the dentoalveolar system. An objective examination revealed that in indirect restorations, marginal periodontium pathology is typical. Conclusions. Aesthetic fixed restorations with a combined occlusal surface have demonstrated good clinical results, even at long-term follow-up. Combining positive properties of two different construction materials, namely zirconium dioxide and ceramics, they reduce the risk of complications such as marginal periodontium pathology and chipping along the occlusal surface as well as contribute to minimal abrasion of the occlusal surfaces of the antagonistic teeth. We cannot recommend metal-plastic restorations due to their low clinical effectiveness, poor aesthetic qualities as well as a high level of marginal periodontium pathology.

  18. Effect of Modifying Prosthetic Socket Base Materials by Adding Nanodiamonds

    Directory of Open Access Journals (Sweden)

    Lifang Ma

    2015-01-01

    Full Text Available The curing process of prosthetic socket base materials requires attention owing to a series of associated problems that are yet to be addressed and solved. However, to date, few relevant studies have been reported. In this paper, nanodiamonds modified with a silane coupling agent were dispersed into a prosthetic socket base material, and the performance of the modified base materials was investigated. Adding a predetermined amount of nanodiamonds to the prosthetic socket base material increased the glass transition temperature, improved the mechanical properties of the cured base material, and reduced the influence of the volatile gas formed during the curing process on the environment. With increasing nanodiamond contents, the glass transition temperature increased and the mechanical properties improved slightly. Owing to the high thermal conductivity of the nanodiamonds, the localized heat, as a result of the curing process, could be dissipated and released. Thus, adding nanodiamonds led to a more uniform temperature field forming in the curing system. This improved the curing process and reduced the formation of volatile monomers, thereby decreasing the adverse impact of the generated volatile gases on the environment. All of these provide a potential strategy for modifying prosthetic socket base materials.

  19. Statement on Publication Ethics for Editors and Publishers

    Science.gov (United States)

    2016-01-01

    The digitization and related developments in journal editing and publishing necessitate increasing the awareness of all stakeholders of science communication in the emerging global problems and possible solutions. Journal editors and publishers are frequently encountered with the fast-growing problems of authorship, conflicts of interest, peer review, research misconduct, unethical citations, and inappropriate journal impact metrics. While the number of erroneous and unethical research papers and wasteful, or 'predatory', journals is increasing exponentially, responsible editors are urged to 'clean' the literature by correcting or retracting related articles. Indexers are advised to implement measures for accepting truly influential and ethical journals and delisting sources with predatory publishing practices. Updating knowledge and skills of authors, editors and publishers, developing and endorsing recommendations of global editorial associations, and (re)drafting journal instructions can be viewed as potential tools for improving ethics of academic journals. The aim of this Statement is to increase awareness of all stakeholders of science communication of the emerging ethical issues in journal editing and publishing and initiate a campaign of upgrading and enforcing related journal instructions. PMID:27510376

  20. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  1. Medical Editors Trial Amnesty (META)

    African Journals Online (AJOL)

    may change jobs, with the result that important work remains unfinished; or investigators may discover a recently published trial on the same topic and conclude that their own results are now redundant. Editors must also take some responsibility. There is a limit to the number of reports we can publish and sometimes we are ...

  2. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  3. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  4. Editor\\'s welcome

    Directory of Open Access Journals (Sweden)

    Hassan Mozaffari-Khosravi

    2016-10-01

    Full Text Available Food and Nutrition Security (FNS has an evolving nature and during the last decades its theoretical, conceptual, structural, practical and programmatic notions evolved significantly and approaches toward food and nutrition have changed drastically. Now, more than ever before, the issue is considered as a fundamental component of sustainable development globally. For a better grasp of the complexities of the field, we need to remind ourselves that “nutrition” as science has a history of more than 100 years while nutrition as a “factor” in “National development” has a history of around fifty years. Considering distinct levels of development status in different contexts, FNS pattern is non-monotonic even in one country. Accordingly, struggling against food and nutrition insecurity is very thought to deal with and multi disciplinary and multi sectorial approaches should be applied. Providing robust evidences to feed policy making processes is one of the main prerequisites for evidence informed policy making and repositioning nutrition as central to sustainable development. This is a professional duty of scholars in different sectors engaging with human development. The journal of Nutrition and Food Security (JNFS as a new journal in the field of food and nutrition security is trying to provide an excellent opportunity for researchers and scholars to publish their original works on approaches, challenges and solutions of food and nutrition hoping to provide data for decision makers to better design interventional programs aiming to eradicate food and nutrition insecurity. Editor in chief H. Mozaffari-Khosravi 22 Sep 2016

  5. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  6. R. E. (Ted) Munn — Founding editor; a mini-biography

    Science.gov (United States)

    Taylor, Peter; Thomas, Morley; Truhlar, Ed; Whelpdale, Doug

    1996-02-01

    Ted Munn founded Boundary-Layer Meteorology in 1970 and served as Editor for 75 volumes over a 25 year period. This short article briefly reviews Ted's scientific career with the Atmospheric Environment Service (of Canada), the International Institute for Applied Systems Analysis in Austria and with the Institute of Environmental Studies at the University of Toronto, and as editor of this journal.

  7. Re-operation for aortic and mitral prosthetic dysfunctions.

    Science.gov (United States)

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  8. Special issues as criterion for journal quality evaluation: Letter to editor

    Directory of Open Access Journals (Sweden)

    Dadkhah Mehdi

    2015-01-01

    Full Text Available Predatory publishers are defined as publishers who have financial goals. This definition was introduced for the first time by Jeffrey Beall (2012. In some predatory publishers, we can find some papers that are not related to journal's aim and scope. These journals create special issues in order to publish papers that are not related to journal's aim and scope. Thus, we are faced with a question of how the editor of these journals could evaluate these papers. In some trusted journals, editor invites guest editors for special issues, which are related to journal's aim and scope. On the other hand predatory publishers, publish papers without any external reviewers or guest editors. In addition, some journals that publish irrelevant papers in regular issues are also found. This problem can be seen especially in some biological or life science journals. It seems that these problems pose new challenge for the academic world.

  9. A model-driven development approach for learning design using the LPCEL Editor

    Directory of Open Access Journals (Sweden)

    Jorge Torres

    2014-01-01

    Full Text Available Complex learning scenarios are represented using Educational Modeling Languages (EMLs. Different people with specific skills usually design these scenarios. The IMS LD is a commonly used EML for which some visual editors are being created in order to assist the authoring process. However, these editors have a limited level of expressiveness and do not provide the facilities for designers to collaborate in the design process. The LPCEL Editor provides a broad level of expressiveness and facilitates the authoring process with an editor that includes: (1 Visual Elements, (2 Intermediate Representation, (3 Learning Patterns, (4 Collaboration tools and (5 Web Services. In order to verify that the components are sufficient, we conducted a user evaluation to analyze their perspective regarding the level of functionality of the tools.

  10. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    Science.gov (United States)

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  11. Experiences of providing prosthetic and orthotic services in Sierra Leone--the local staff's perspective.

    Science.gov (United States)

    Magnusson, Lina; Ahlström, Gerd

    2012-01-01

    In Sierra Leone, West Africa, there are many people with disabilities in need of rehabilitation services after a long civil war. The aim of this qualitative study was to explore the experiences of prosthetic and orthotic service delivery in Sierra Leone from the local staff's perspective. Fifteen prosthetic and orthotic technicians working at all the rehabilitation centres providing prosthetic and orthotic services in Sierra Leone were interviewed. The interviews were transcribed and subjected to latent content analysis. One main theme emerged: sense of inability to deliver high-quality prosthetic and orthotic services. This main theme was generated from eight sub-themes: Desire for professional development; appraisals of work satisfaction and norms; patients neglected by family; limited access to the prosthetic and orthotic services available; problems with materials and machines; low public awareness concerning disabilities; marginalisation in society and low priority on the part of government. The findings illustrated traditional beliefs about the causes of disability and that the public's attitude needs to change to include and value people with disabilities. Support from international organisations was considered necessary as well as educating more prosthetic and orthotic staff to a higher level.

  12. Consumer satisfaction with the services of prosthetics and orthotics facilities.

    Science.gov (United States)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U

    2009-03-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (P&O) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 P&O facilities in The Netherlands. Consumers (n = 1,364) of these P&O facilities who were fitted with a prosthesis, orthopaedic shoes, an orthosis, or another device, were asked to rate the overall services provided and whether they were satisfied with the device provided and its delivery time. Additionally, they filled in a modified SERVQUAL questionnaire (see Appendix). Consumers gave the service provided by P&O facilities a mean overall rating of 8.1. The highest ratings were given by consumers fitted with a prosthesis (mean overall rating of services: 8.4). In total, 78% of the consumers were satisfied with the device provided and 93% with the delivery time. The results of our study showed that, on the SERVQUAL, 50% of the statements fulfilled the criteria for a satisfactory quality of the services. The overall consumer rating of the service provided by P&O facilities is high and depends on the device provided. The outcomes on the SERVQUAL were moderate. In future, it is important to study consumer satisfaction more extensively in order to improve the quality of P&O services in daily practice. Additionally, specific questionnaires need to be developed to measure all aspects of prosthetic and orthotic care, with the aim to improve the services.

  13. Capnocytophaga canimorsus: a rare case of conservatively treated prosthetic valve endocarditis.

    Science.gov (United States)

    Jalava-Karvinen, Päivi; Grönroos, Juha O; Tuunanen, Helena; Kemppainen, Jukka; Oksi, Jarmo; Hohenthal, Ulla

    2018-05-01

    We describe a rare case of prosthetic valve endocarditis caused by the canine bacterium Capnocytophaga canimorsus in a male aged 73 years. The diagnosis of infective endocarditis was unequivocal, as it blood cultures were positive for C. canimorsus and vegetations were detected on transesophageal echocardiography; the modified Duke criteria were fulfilled. PET-CT showed intense 18 F-FDG uptake of the prosthetic valve area. The patient was treated with antibiotics alone (no surgery), and is now on life-long suppressive antibiotic therapy. To our knowledge, this is the third reported case of prosthetic valve endocarditis caused by C. canimorsus and the first one to have been treated conservatively. © 2018 APMIS. Published by John Wiley & Sons Ltd.

  14. Survey Research in the Forest Science Journals - Insights from Journal Editors

    Directory of Open Access Journals (Sweden)

    Mirjana Stevanov

    2015-06-01

    Full Text Available Background and Purpose: Survey research is one of the most commonly applied approaches in the social sciences. In the forest research it has been used for more than five decades. In spite of that or the fact that the amount of survey-based articles in the forest science journals has increased during the last decade, their share in all articles published in 20 forest science journals (9,372 articles, 2005-2014 is quite modest (3.2%. In our paper we look at the opinions and attitudes of forest science journal editors towards survey research, as their perspective might enlarge our understanding of the use of this approach in the field of forestry. Materials and Methods: We selected 20 forest science journals - 15 from the SCI list and five non-SCI journals and contacted editors of these journals with the self-administered e-mail questionnaire. Data were collected in October 2014 and analyzed by descriptive statistics. The overall response rate was 75%. The assumptions for the study were based on the evidence addressing opinions and attitudes of journal editors from other research fields (finance since no similar study was found in the field of forestry. Results: The majority of editors reported the same review process for survey-based articles as for all others. In two journals, articles with the survey-based content are screened more rigorously and in two journals their publishing is generally discouraged. 40% of journal editors hold the view that no difference should be made between survey research and other types of original research, and another 40% think that survey research should in the first place play a complementary role. As the main strength of survey research editors see the possibility to obtain data unavailable from other sources. They perceive adverse selection and the difficulty to generalize results as the main weaknesses. Conclusions: Editors of forest science journals have similar opinion on survey research as those from the

  15. Four are named Editors of Earth Interactions

    Science.gov (United States)

    Eric J. Barron of the Earth System Science Center at The Pennsylvania State University has been named chief editor of the new electronic journal, Earth Interactions. This journal will be co-published by AGU, the American Meteorological Society, and the Association of American Geographers. The three societies jointly agreed on the appointment of Barron. Each of the societies also appointed an editor to the board. George F. Hepner for AAG is from the Department of Geography at the University of Utah, David T. Sandwell for AGU is at the Institute of Geophysics and Planetary Physics at Scripps Institution of Oceanography, and Kevin E. Trenberth for AMS is at the Climate and Global Dynamics Division at the National Center for Atmospheric Research.

  16. Mitral Prosthetic Valve Obstruction and Its Complications

    Directory of Open Access Journals (Sweden)

    Rajesh Rajan

    2015-12-01

    Full Text Available Prosthetic Valve Obstruction (PVO is a serious complication which is associated with increased morbidity and mortality. This could result from thrombus formation, development of pannus, or a combination of both. Patients with this complication often present with symptoms and signs of heart failure, systemic embolism, acute cardiovascular collapse, and sudden death. Transesophageal echocardiography and cine fluoroscopy play a vital role in diagnosis of this potentially lethal condition. Herein, we reported a 56-year-old male patient who presented with severe heart failure and was found to have obstructed ATS27 bileaflet mitral prosthetic valve. Thrombolysis and redo surgery are two important options for treating this condition although guidelines for choosing between the two are not very definite.

  17. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Amjad Alwaal

    2017-01-01

    Conclusions: There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  18. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report.

    Science.gov (United States)

    Somayaji, R; Lynch, T; Powell, J N; Gregson, D

    2016-11-04

    Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. A case of chronic hip prosthetic joint infection (PJI) caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  19. Prosthetic Need between Different Age and Gender ‎With Patient Attending College of Dentistry,Tikrit ‎University

    Directory of Open Access Journals (Sweden)

    Reem Ahmed Shihab‎

    2017-12-01

    Full Text Available Background: the most important factor that affects speak, mastication and aesthetics is tooth loss which in turn imitated on the quality of life. The goal of our research was to evaluate the prosthetic need in sample attending prosthetic department and compare between age and gender. Material and methods: A sample of 244 patients was randomly chosen for questionnaire in the (Removable Prosthodontics Clinic into College of Dentistry-Tikrit University. All subjects were divided in six groups according to their age and also divided according to gender. Intraoral examinations were performed and reasons for extraction were recorded. All statistic calculations were performed using SPSS 23 (Statistical Package for Social Sciences. Results: The total number of 244 patients was involved in this study: 165 (67.6% males and 79 (32.4% females. We found that the higher percentage of patients were in the age group of (20-29 for males which was (23%, 56 patient, while the higher female percentage was found in the age group of (40-49 which was 11.5% . Reasons for extraction recorded the higher percentage due to Caries for both males (75.2% & females (81 % as suspected. Conclusion:The number of patient attending prosthetic department male more than female. Dental caries were the principal cause for extractions in younger patients followed by periodontitis. Society needs more motivation about dental health and care.

  20. Handing Over the ATLAS eNews Scientific Editor Task

    CERN Multimedia

    P. Jenni

    2006-01-01

    The ATLAS eNews are now established since many years as a lively source of stories about the construction of our detector as well as the preparations for the physics running to come. The human touch in telling these stories is important, and to stimulate and motivate the article writers to include also this side of our work is one of the tasks for the Scientific Editor of the eNews. Joleen ('Jo') Pater has been the enthusiastic and competent 'skipper' for the last two years keeping the eNews on track. The whole Collaboration owes her a great and very hearty thank-you! Pauline Gagnon has kindly accepted to take up the challenge for the next couple of years. She will have the privilege to be the editor when we will see the first collisions with ATLAS! I wish her all the best for this new task. Outgoing and incoming editors of the ATLAS E-news: Jo Pater (left) and Pauline Gagnon (right)

  1. DME Prosthetics Orthotics, and Supplies Fee Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — Durable Medical Equipment, Prosthetics-Orthotics, and Supplies Fee Schedule. The list contains the fee schedule amounts, floors, and ceilings for all procedure codes...

  2. Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.

    Science.gov (United States)

    Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P

    2008-12-01

    The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.

  3. 29 CFR 793.11 - Combination announcer, news editor and chief engineer.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Combination announcer, news editor and chief engineer. 793... OF CERTAIN RADIO AND TELEVISION STATION EMPLOYEES FROM OVERTIME PAY REQUIREMENTS UNDER SECTION 13(b... editor and chief engineer. The 13(b)(9) exemption, as was made clear during the debate on the amendment...

  4. [Virtual Planning of Prosthetic Treatment of the Orbit].

    Science.gov (United States)

    Veit, Johannes A; Thierauf, Julia; Egner, Kornelius; Wiggenhauser, Paul Severin; Friedrich, Daniel; Greve, Jens; Schuler, Patrick J; Hoffmann, Thomas K; Schramm, Alexander

    2017-06-01

    Optimal positioning of bone-anchored implants in the treatment of patients with orbital prosthesis is challenging. The definition of implant axis as well as the positioning of the implants is important to prevent failures in prosthetic rehabilitation in these patients. We performed virtual planning of enossal implants at a base of a standard fan beam CT scan using the software CoDiagnostiX™ (DentalWings, Montréal, Canada). By 3D-printing a surgical guide for drilling and implant insertion was manufactured (Med-610™, Stratasys, Rehovot, Israel). An orbital exenteration was performed in a patient after shrinkage of the eyelids 20 years after enucleation and radiation of the orbit due to rhabdomyosarcoma. 4 Vistafix-3 implants (Cochlear™, Cochlea, Centennial, USA) were primarily inserted after resection with the help of the 3D-surgical guide. Prosthetic rehabilitation could be achieved as preplanned to a predictable result. The individual prosthesis of the orbit showed good functional and esthetic outcome. The virtual 3D-planning of endosseous implants for prosthetic orbital and periorbital reconstruction is easy to use and facilitates optimal placement of implants especially in posttherapeutically altered anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Development of inexpensive prosthetic feet for high-heeled shoes using simple shoe insole model.

    Science.gov (United States)

    Meier, Margrit R; Tucker, Kerice A; Hansen, Andrew H

    2014-01-01

    The large majority of prosthetic feet are aimed at low-heeled shoes, with a few models allowing a heel height of up to 5 cm. However, a survey by the American Podiatric Medical Association indicates that most women wear heels over 5 cm; thus, current prosthetic feet limit most female prosthesis users in their choice. Some prosthetic foot components are heel-height adjustable; however, their plantar surface shapes do not change to match the insole shapes of the shoes with different heel heights. The aims of the study were therefore (1) to develop a model that allows prediction of insole shape for various heel height shoes in combination with different shoe sizes and (2) to develop and field-test low-cost prototypes of prosthetic feet whose insole shapes were based on the new model. An equation was developed to calculate insole shapes independent of shoe size. Field testing of prototype prosthetic feet fabricated based on the equation was successful and demonstrated the utility of the equation.

  6. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  7. Prosthetic Hip Loosening Due to Brucellar Infection: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2016-12-01

    Full Text Available Context: Brucellosis is actually considered to be the commonest zoonotic infection worldwide; conversely prosthetic infection due to brucella is extremely rare. Although diagnostic is easily achieved, management of such situations is extremely challenging. Aims: To report the case of prosthetic hip loosening due to brucellar infection, discuss management manners and to summarize data about 19 cases reported in the literature. Methods: We report the case of a 73-year-old woman with brucellar prosthetic hip loosening treated with 2-stage exchange of the prosthesis and prolonged double antibiotherapy Results: At two years follow up the patient is pain free with total functional recovery and no clinical and radiographic signs of prosthetic loosening Conclusions: Brucella should be evocated as a cause of total joint arthroplasty infection especially in patients from endemic regions and with occupational exposure. Antibiotic treatment alone can be followed if there are no signs of implant loosening. Tow stage revision should be considered in other cases.

  8. Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery.

    Science.gov (United States)

    Kohler, Philipp; Kuster, Stefan P; Bloemberg, Guido; Schulthess, Bettina; Frank, Michelle; Tanner, Felix C; Rössle, Matthias; Böni, Christian; Falk, Volkmar; Wilhelm, Markus J; Sommerstein, Rami; Achermann, Yvonne; Ten Oever, Jaap; Debast, Sylvia B; Wolfhagen, Maurice J H M; Brandon Bravo Bruinsma, George J; Vos, Margreet C; Bogers, Ad; Serr, Annerose; Beyersdorf, Friedhelm; Sax, Hugo; Böttger, Erik C; Weber, Rainer; van Ingen, Jakko; Wagner, Dirk; Hasse, Barbara

    2015-10-21

    We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater-cooler unit of the heart-lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Interdisciplinary care and follow-up of all patients was documented by the study team. Patients' characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36-76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5-40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogens. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  9. Virtual Control of Prosthetic Hand Based on Grasping Patterns and Estimated Force from Semg

    Directory of Open Access Journals (Sweden)

    Zhu Gao-Ke

    2016-01-01

    Full Text Available Myoelectric prosthetic hands aim to serve upper limb amputees. The myoelectric control of the hand grasp action is a kind of real-time or online method. Thus it is of great necessity to carry on a study of online prosthetic hand electrical control. In this paper, the strategy of simultaneous EMG decoding of grasping patterns and grasping force was realized by controlling a virtual multi-degree-freedom prosthetic hand and a real one-degree-freedom prosthetic hand simultaneously. The former realized the grasping patterns from the recognition of the sEMG pattern. The other implemented the grasping force from sEMG force decoding. The results show that the control method is effective and feasible.

  10. Thanks to outgoing Associate Editors

    Science.gov (United States)

    Lichti, Derek D.; Weng, Qihao

    2018-04-01

    As of the end of December 2017, Professors Eberhard Gülch, Olaf Hellwich, Minho Kim, and Lalit Kumar have retired as Associate Editors of the ISPRS Journal of Photogrammetry and Remote Sensing. Our Journal's readership has benefited greatly from their longstanding commitment to their editorial duties. Both Profs. Gülch and Hellwich began their service to the Journal in 2007, while Profs. Kumar and Kim began in 2012 and 2014, respectively. In their many years as editors, they have witnessed the incredible growth of the Journal in terms of the number of papers submitted and published as well as the impact factor. Thanks to their high standards for paper quality and rigorous peer review, these professors have been important contributors to the Journal's current high standing. They were very versatile in terms of the scope of papers they could handle. Eberhard handled papers in photogrammetry, terrain modelling and geographic information systems (GIS) while Olaf handled papers in radar, computer vision and GIS. Both Lalit and Minho handled papers in optical remote sensing. On behalf of the Journal and the International Society for Photogrammetry and Remote Sensing, we thank them for many years of dedicated service to the Journal.

  11. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report

    Directory of Open Access Journals (Sweden)

    R. Somayaji

    2016-11-01

    Full Text Available Abstract Background Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. Case presentation A case of chronic hip prosthetic joint infection (PJI caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. Conclusions We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  12. Carta del Editor

    OpenAIRE

    Luis Eladio Proaño

    2015-01-01

    Henos aquí con un nuevo número de RIESED. Después de casi un año de ver la luz, y como lo anticipábamos en la carta del editor que acompañaba al número fundacional, hacer una revista electrónica no ha sido una tarea sencilla. Un año más tarde no podemos sino confirmar esa opinión.Gracias al decidido trabajo de los autores, revisores y miembros del equipo editorial hemos podido hacerlo. El proceso de revisión de los artículos ha merecido un cuidado, dedicación y tiempo especiales, que hicieron...

  13. In vitro adherence of bacteria to prosthetic grafting materials

    International Nuclear Information System (INIS)

    Brewer, A.R.; Stromberg, B.V.

    1990-01-01

    Adherence of bacteria to prosthetic grafting material is thought to play an important role in the ultimate development of prosthetic infections. To evaluate the role of bacterial adherence in the initiation and colonization of prosthetic materials, Proplast II, Gore-Tex, and silicone were evaluated for adherence of Escherichia coli and Staphylococcus aureus. Bacteria were radiolabeled and incubated with the study material. Adherence was determined by scintillation. Adherence to Proplast II and Gore-Tex reached a maximum at approximately 45 minutes of incubation and demonstrated a detachment phenomenon with E. coli. Similar results were noted with S. aureus, but with a maximal attachment at approximately 30 minutes. Interestingly, bacterial attachment to silicone continued to increase throughout the time of the incubation. In addition, adherence of S. aureus was at a faster rate than E. coli. Attachment of bacteria is a multifactorial process. However, the PTFE graft demonstrates a slower rate of attachment, lower total number of attached bacteria, and faster detachment. The importance of this phenomenon may help explain the foreign body effect of increased susceptibility to infection of foreign materials

  14. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  15. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  16. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  17. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  18. Rapidly growing non-tuberculous mycobacteria infection of prosthetic knee joints: A report of two cases.

    Science.gov (United States)

    Kim, Manyoung; Ha, Chul-Won; Jang, Jae Won; Park, Yong-Beom

    2017-08-01

    Non-tuberculous mycobacteria (NTM) cause prosthetic knee joint infections in rare cases. Infections with rapidly growing non-tuberculous mycobacteria (RGNTM) are difficult to treat due to their aggressive clinical behavior and resistance to antibiotics. Infections of a prosthetic knee joint by RGNTM have rarely been reported. A standard of treatment has not yet been established because of the rarity of the condition. In previous reports, diagnoses of RGNTM infections in prosthetic knee joints took a long time to reach because the condition was not suspected, due to its rarity. In addition, it is difficult to identify RGNTM in the lab because special identification tests are needed. In previous reports, after treatment for RGNTM prosthetic infections, knee prostheses could not be re-implanted in all cases but one, resulting in arthrodesis or resection arthroplasty; this was most likely due to the aggressiveness of these organisms. In the present report, two cases of prosthetic knee joint infection caused by RGNTM (Mycobacterium abscessus) are described that were successfully treated, and in which prosthetic joints were finally reimplanted in two-stage revision surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Does integrating research into the prosthetics and orthotics undergraduate curriculum enhance students' clinical practice? An interview study on students' perception.

    Science.gov (United States)

    Al Qaroot, Bashar S; Sobuh, Mohammad

    2016-06-01

    Problem-based learning (where rather than feeding students the knowledge, they look for it themselves) has long been thought of as an ideal approach in teaching because it would encourage students to acquire knowledge from an undetermined medium of wrong and right answers. However, the effect of such approach in the learning experience of prosthetics and orthotics students has never been investigated. This study explores the implications of integrating problem-based learning into teaching on the students' learning experience via implementing a research-informed clinical practice module into the curriculum of last year prosthetics and orthotics undergraduate students at the University of Jordan (Amman, Jordan). Qualitative research pilot study. Grounded theory approach was used based on the data collected from interviewing a focus group of four students. Students have identified a number of arguments from their experience in the research-informed clinical practice where, generally speaking, students described research-informed clinical practice as a very good method of education. Integrating problem-based learning into teaching has many positive implications. In particular, students pointed out that their learning experience and clinical practice have much improved after the research-informed clinical practice. Findings from this investigation demonstrate that embedding problem-based learning into prosthetics and orthotics students' curriculum has the potential to enhance students' learning experience, particularly students' evidence-based practice. This may lead to graduates who are more knowledgeable and thus who can offer the optimal patient care (i.e. clinical practice). © The International Society for Prosthetics and Orthotics 2014.

  20. Dutch evidence-based guidelines for amputation and prosthetics of the lower extremity : Rehabilitation process and prosthetics. Part 2

    NARCIS (Netherlands)

    Geertzen, Jan; van der Linde, Harmen; Rosenbrand, Kitty; Conradi, Marcel; Deckers, Jos; Koning, Jan; Rietman, Hans S.; van der Schaaf, Dick; van der Ploeg, Rein; Schapendonk, Johannes; Schrier, Ernst; Duijzentkunst, Rob Smit; Spruit-van Eijk, Monica; Versteegen, Gerbrig; Voesten, Harrie

    2015-01-01

    Background: A structured, multidisciplinary approach in the rehabilitation process after amputation is needed that includes a greater focus on the involvement of both (para)medics and prosthetists. There is considerable variation in prosthetic prescription concerning the moment of initial prosthesis

  1. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. A Statistical Perspective on Running with Prosthetic Lower-Limbs: An Advantage or Disadvantage?

    Directory of Open Access Journals (Sweden)

    Hossein Hassani

    2014-11-01

    Full Text Available Technological developments have led to the increased use of carbon fiber and prosthetic lower-limbs in running events at the Paralympic Games. This study aims to exploit a series of statistical techniques in order to prepare a response to the vital question of whether utilizing prosthetic feet can affect an athletes ability when running competitively at the Paralympics Games by comparing both within and between different classifications. The study also considers the differences between running on biological limbs and prosthetic lower-limbs from a mechanical point of view. The results from the male 100 m, 200 m and 400 m at the 2012 London Paralympic Games have been the source of this investigation. The investigation provides statistical evidence to propose that the number of prosthetic limbs used and the structure of such limbs have a significant impact on the outcome of track events at the Paralympic Games.

  3. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    International Nuclear Information System (INIS)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    2014-01-01

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if timely management is started. Literature shows no uniform advise on diagnosis. The EANM organized a consensus meeting with representatives from the involved disciplines in order to develop common flowcharts for the diagnosis of osteomyelitis, spondylodiscitis and prosthetic joint infections. In this report the proceedings of this consensus meeting, including the proposed flowcharts for diagnosis, are published.

  4. Mobility function of a prosthetic knee joint with an automatic stance phase lock.

    Science.gov (United States)

    Andrysek, Jan; Klejman, Susan; Torres-Moreno, Ricardo; Heim, Winfried; Steinnagel, Bryan; Glasford, Shane

    2011-06-01

    There is a need for a prosthetic knee joint design that is technologically and functionally appropriate for use in developing countries. To develop and clinically evaluate a new type of stance phase controlled prosthetic knee joint that provides stance phase stability without inhibiting swing phase flexion. A crossover repeated measures study design comparing the new knee joint to the participant's conventional low- or high-end prosthetic knee joint. The new knee joint was fitted to fourteen individuals aged 15 to 67 years with unilateral lower limb amputations. Walk tests were performed to measure walking speed. Energy expenditure was estimated using the physiological cost index (PCI). Walking speeds with the new knee joint were on average 0.14 m/s faster than conventional low-end knees (p < 0.0001), but 0.07 m/s slower than conventional high-end prosthetic knees (p = 0.008). The PCI was similar across all three knee joint technologies (p = 0.276). Mobility function with the new knee joint, in terms of walking speed, was more closely matched to high-end than low-end prosthetic knee joints. Therefore, given its relatively simple design, the new stance phase control mechanism may offer a functional and cost effective solution for active transfemoral amputees. This paper describes a new type of prosthetic knee joint mechanism that is intended to be cost-effective while providing high-level stance phase function to active individuals with a transfemoral amputation. Initial clinical testing suggests that the new knee joint may have some functional advantages over existing technologies in this category.

  5. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.

    Science.gov (United States)

    Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq

    2014-08-01

    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.

  6. Development of inexpensive prosthetic feet for high-heeled shoes using simple shoe insole model

    OpenAIRE

    Margrit R. Meier, PhD; Kerice A. Tucker, BSc; Andrew H. Hansen, PhD

    2014-01-01

    The large majority of prosthetic feet are aimed at low-heeled shoes, with a few models allowing a heel height of up to 5 cm. However, a survey by the American Podiatric Medical Association indicates that most women wear heels over 5 cm; thus, current prosthetic feet limit most female prosthesis users in their choice. Some prosthetic foot components are heel-height adjustable; however, their plantar surface shapes do not change to match the insole shapes of the shoes with different heel height...

  7. A global perspective on mechanical prosthetic heart valve thrombosis: Diagnostic and therapeutic challenges

    Science.gov (United States)

    Gürsoy, Mustafa Ozan; Kalçık, Macit; Yesin, Mahmut; Karakoyun, Süleyman; Bayam, Emrah; Gündüz, Sabahattin; Özkan, Mehmet

    2016-01-01

    Prosthetic valve thrombosis is one of the major causes of primary valve failure, which can be life-threatening. Multimodality imaging is necessary for determination of leaflet immobilization, cause of underlying pathology (thrombus versus pannus or both), and whether thrombolytic therapy attempt in the patient would be successful or surgery is needed. Current guidelines for the management of prosthetic valve thrombosis lack definitive class I recommendations due to lack of randomized controlled trials, and usually leave the choice of treatment to the clinician’s experience. In this review, we aimed to summarize the pathogenesis, diagnosis, and management of mechanical prosthetic valve thrombosis. PMID:28005024

  8. Echocardiographic Evaluation of Tricuspid Prosthetic Valves: An Update

    Directory of Open Access Journals (Sweden)

    Dimitrios Maragiannis, MD, FASE, FACC

    2016-05-01

    Full Text Available This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.

  9. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  10. The graphics editor in ROOT

    International Nuclear Information System (INIS)

    Antcheva, Ilka; Brun, Rene; Hof, Carsten; Rademakers, Fons

    2006-01-01

    A well-designed Graphical User Interface (GUI) has critical importance in any computer application. The user interface is where the end users and the complex system intersect. An effective interface design can make a powerful and complex system, such as ROOT, easy and intuitive to learn and operate. This paper describes the main goals we defined and the design solution we found developing the graphics editor in ROOT

  11. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.

    Science.gov (United States)

    Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng

    2013-01-01

    Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.

  12. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    Science.gov (United States)

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  13. The XML Metadata Editor of GFZ Data Services

    Science.gov (United States)

    Ulbricht, Damian; Elger, Kirsten; Tesei, Telemaco; Trippanera, Daniele

    2017-04-01

    Following the FAIR data principles, research data should be Findable, Accessible, Interoperable and Reuseable. Publishing data under these principles requires to assign persistent identifiers to the data and to generate rich machine-actionable metadata. To increase the interoperability, metadata should include shared vocabularies and crosslink the newly published (meta)data and related material. However, structured metadata formats tend to be complex and are not intended to be generated by individual scientists. Software solutions are needed that support scientists in providing metadata describing their data. To facilitate data publication activities of 'GFZ Data Services', we programmed an XML metadata editor that assists scientists to create metadata in different schemata popular in the earth sciences (ISO19115, DIF, DataCite), while being at the same time usable by and understandable for scientists. Emphasis is placed on removing barriers, in particular the editor is publicly available on the internet without registration [1] and the scientists are not requested to provide information that may be generated automatically (e.g. the URL of a specific licence or the contact information of the metadata distributor). Metadata are stored in browser cookies and a copy can be saved to the local hard disk. To improve usability, form fields are translated into the scientific language, e.g. 'creators' of the DataCite schema are called 'authors'. To assist filling in the form, we make use of drop down menus for small vocabulary lists and offer a search facility for large thesauri. Explanations to form fields and definitions of vocabulary terms are provided in pop-up windows and a full documentation is available for download via the help menu. In addition, multiple geospatial references can be entered via an interactive mapping tool, which helps to minimize problems with different conventions to provide latitudes and longitudes. Currently, we are extending the metadata editor

  14. The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees.

    Science.gov (United States)

    Morgenroth, David C; Segal, Ava D; Zelik, Karl E; Czerniecki, Joseph M; Klute, Glenn K; Adamczyk, Peter G; Orendurff, Michael S; Hahn, Michael E; Collins, Steven H; Kuo, Art D

    2011-10-01

    Lower extremity amputation not only limits mobility, but also increases the risk of knee osteoarthritis of the intact limb. Dynamic walking models of non-amputees suggest that pushing-off from the trailing limb can reduce collision forces on the leading limb. These collision forces may determine the peak knee external adduction moment (EAM), which has been linked to the development of knee OA in the general population. We therefore hypothesized that greater prosthetic push-off would lead to reduced loading and knee EAM of the intact limb in unilateral transtibial amputees. Seven unilateral transtibial amputees were studied during gait under three prosthetic foot conditions that were intended to vary push-off. Prosthetic foot-ankle push-off work, intact limb knee EAM and ground reaction impulses for both limbs during step-to-step transition were measured. Overall, trailing limb prosthetic push-off work was negatively correlated with leading intact limb 1st peak knee EAM (slope=-.72±.22; p=.011). Prosthetic push-off work and 1st peak intact knee EAM varied significantly with foot type. The prosthetic foot condition with the least push-off demonstrated the largest knee EAM, which was reduced by 26% with the prosthetic foot producing the most push-off. Trailing prosthetic limb push-off impulse was negatively correlated with leading intact limb loading impulse (slope=-.34±.14; p=.001), which may help explain how prosthetic limb push-off can affect intact limb loading. Prosthetic feet that perform more prosthetic push-off appear to be associated with a reduction in 1st peak intact knee EAM, and their use could potentially reduce the risk and burden of knee osteoarthritis in this population. Published by Elsevier B.V.

  15. Transparent Model Transformation: Turning Your Favourite Model Editor into a Transformation Tool

    DEFF Research Database (Denmark)

    Acretoaie, Vlad; Störrle, Harald; Strüber, Daniel

    2015-01-01

    Current model transformation languages are supported by dedicated editors, often closely coupled to a single execution engine. We introduce Transparent Model Transformation, a paradigm enabling modelers to specify transformations using a familiar tool: their model editor. We also present VMTL, th...... model transformation tool sharing the model editor’s benefits, transparently....

  16. Correction of β-thalassemia mutant by base editor in human embryos

    Directory of Open Access Journals (Sweden)

    Puping Liang

    2017-09-01

    Full Text Available Abstract β-Thalassemia is a global health issue, caused by mutations in the HBB gene. Among these mutations, HBB −28 (A>G mutations is one of the three most common mutations in China and Southeast Asia patients with β-thalassemia. Correcting this mutation in human embryos may prevent the disease being passed onto future generations and cure anemia. Here we report the first study using base editor (BE system to correct disease mutant in human embryos. Firstly, we produced a 293T cell line with an exogenous HBB −28 (A>G mutant fragment for gRNAs and targeting efficiency evaluation. Then we collected primary skin fibroblast cells from a β-thalassemia patient with HBB −28 (A>G homozygous mutation. Data showed that base editor could precisely correct HBB −28 (A>G mutation in the patient’s primary cells. To model homozygous mutation disease embryos, we constructed nuclear transfer embryos by fusing the lymphocyte or skin fibroblast cells with enucleated in vitro matured (IVM oocytes. Notably, the gene correction efficiency was over 23.0% in these embryos by base editor. Although these embryos were still mosaic, the percentage of repaired blastomeres was over 20.0%. In addition, we found that base editor variants, with narrowed deamination window, could promote G-to-A conversion at HBB −28 site precisely in human embryos. Collectively, this study demonstrated the feasibility of curing genetic disease in human somatic cells and embryos by base editor system.

  17. An Interview with Masoud Yazdani, editor of London-based Intellect Books

    Directory of Open Access Journals (Sweden)

    Sean Scanlan

    2014-03-01

    Full Text Available Sean Scanlan conducted an email interview with Masoud Yazdani, the editor of Intellect Books, an independent academic publisher in the fields of creative practice and popular culture, whose aim is to publish scholarly books and journals that provide a vital space for widening critical debate in new and emerging subjects. An Interview with Masoud Yazdani, editor of London-based Intellect Books by Sean Scanlan.

  18. An international survey and modified Delphi process revealed editors' perceptions, training needs, and ratings of competency-related statements for the development of core competencies for scientific editors of biomedical journals.

    Science.gov (United States)

    Galipeau, James; Cobey, Kelly D; Barbour, Virginia; Baskin, Patricia; Bell-Syer, Sally; Deeks, Jonathan; Garner, Paul; Shamseer, Larissa; Sharon, Straus; Tugwell, Peter; Winker, Margaret; Moher, David

    2017-01-01

    Background: Scientific editors (i.e., those who make decisions on the content and policies of a journal) have a central role in the editorial process at biomedical journals. However, very little is known about the training needs of these editors or what competencies are required to perform effectively in this role. Methods: We conducted a survey of perceptions and training needs among scientific editors from major editorial organizations around the world, followed by a modified Delphi process in which we invited the same scientific editors to rate the importance of competency-related statements obtained from a previous scoping review. Results: A total of 148 participants completed the survey of perceptions and training needs. At least 80% of participants agreed on six of the 38 skill and expertise-related statements presented to them as being important or very important to their role as scientific editors. At least 80% agreed on three of the 38 statements as necessary skills they perceived themselves as possessing (well or very well).  The top five items on participants' list of top training needs were training in statistics, research methods, publication ethics, recruiting and dealing with peer reviewers, and indexing of journals. The three rounds of the Delphi were completed by 83, 83, and 73 participants, respectively, which ultimately produced a list of 23 "highly rated" competency-related statements and another 86 "included" items. Conclusion: Both the survey and the modified Delphi process will be critical for understanding knowledge and training gaps among scientific editors when designing curriculum around core competencies in the future.

  19. Prosthetic valves in adult patients with congenital heart disease : Rationale and design of the Dutch PROSTAVA study

    NARCIS (Netherlands)

    Freling, H. G.; van Slooten, Y. J.; van Melle, J. P.; Mulder, B. J. M.; van Dijk, A. P. J.; Hillege, H. L.; Post, M. C.; Sieswerda, G. Tj; Jongbloed, M. R. M.; Willems, T. P.; Pieper, P. G.

    2012-01-01

    Data on long-term complications in adult patients with congenital heart disease (ACHD) and a prosthetic valve are scarce. Moreover, the influence of prosthetic valves on quality of life (QoL) and functional outcome in ACHD patients with prosthetic valves has not been studied. The primary objective

  20. Advances for prosthetic technology from historical perspective to current status to future application

    CERN Document Server

    LeMoyne, Robert

    2016-01-01

    This book focuses on the advances in transtibial prosthetic technology and targets research in the evolution of the powered prosthesis such as the BiOM, which was derived from considerable research and development at the Massachusetts Institute of Technology. The concept of the book spans the historical evolution of prosthetic applications from passive to new and futuristic robotic prosthetic technologies.  The author describes the reasons for amputation, surgical procedures, and an historical perspective of the prosthesis for the lower limb. He also addresses the phases and sub-phases of gait and compensatory mechanisms arising for a transtibial prosthesis and links the compensatory mechanisms to long-term morbidities.  The general technologies for gait analysis central to prosthetic design and the inherent biomechanics foundations for analysis are also explored.  The book reports on recent-past to current-term applications with passive elastic prostheses.  The core of the book deals with futuristic robo...

  1. Multimodality Imaging Assessment of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Suchá, D.; Symersky, Petr; Tanis, W; Mali, Willem P Th M; Leiner, Tim; van Herwerden, LA; Budde, Ricardo P J

    Echocardiography and fluoroscopy are the main techniques for prosthetic heart valve (PHV) evaluation, but because of specific limitations they may not identify the morphological substrate or the extent of PHV pathology. Cardiac computed tomography (CT) and magnetic resonance imaging (MRI) have

  2. Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

    Directory of Open Access Journals (Sweden)

    Manelle Merad

    2018-02-01

    Full Text Available Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supination, and a body-powered elbow. Unlike healthy upper limb movements, the prosthetic elbow joint angle, adjusted prior to the motion, is not involved in the overall upper limb movements, causing the rest of the body to compensate for the lack of mobility of the prosthesis. A promising solution to improve upper limb prosthesis control exploits the residual limb mobility: like in healthy movements, shoulder and prosthetic elbow motions are coupled using inter-joint coordination models. The present study aims to test this approach. A transhumeral amputated individual used a prosthesis with a residual limb motion-driven elbow to point at targets. The prosthetic elbow motion was derived from IMU-based shoulder measurements and a generic model of inter-joint coordinations built from healthy individuals data. For comparison, the participant also performed the task while the prosthetic elbow was implemented with his own myoelectric control strategy. The results show that although the transhumeral amputated participant achieved the pointing task with a better precision when the elbow was myoelectrically-controlled, he had to develop large compensatory trunk movements. Automatic elbow control reduced trunk displacements, and enabled a more natural body behavior with synchronous shoulder and elbow motions. However, due to socket impairments, the residual limb amplitudes were not as large as those of healthy shoulder movements. Therefore, this work also investigates if a control strategy whereby prosthetic joints are automatized according to healthy individuals

  3. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  4. Prevention of dental anomalies in children by prosthetics defects hard tooth tissues and dentitions: the need to possibilities

    Directory of Open Access Journals (Sweden)

    Suetenkov D.Ye.

    2011-03-01

    Full Text Available This article presents the possibility of restore the function and anatomy of the tooth and replacement of defects of dentition by prosthesis in children under the removable bite as a method of prevention of dentoalveolar anomalies. Identified the need for prosthetic treatment of children and the willingness of dentists as primary health care professional to address the problems identified. A clinical analysis of complex treatment of defects in the teeth with fixed restorations

  5. Case study: survey of patient satisfaction with prosthesis quality and design among below-knee prosthetic leg socket users.

    Science.gov (United States)

    Mohd Hawari, Nurhanisah; Jawaid, Mohammad; Md Tahir, Paridah; Azmeer, Raja Ahmad

    2017-11-01

    The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.

  6. Ethical Guideline to Authors,Editors,and Reviewers

    Institute of Scientific and Technical Information of China (English)

    Editorial office of CHM

    2016-01-01

    Drug products are specific goods with safety and effectiveness in medical health case.All of researchers(authors),reviewers,and editors must abide by medical ethical obligation,and also must deter to the ethical obligation for publication.These guidelines are offered as ethical

  7. Factors influencing the cost of prosthetic joint infection treatment.

    Science.gov (United States)

    Peel, T N; Cheng, A C; Lorenzo, Y P; Kong, D C M; Buising, K L; Choong, P F M

    2013-11-01

    Prosthetic joint infection (PJI) is associated with significant costs to the healthcare system. Current literature examines the cost of specific treatment modalities without assessing other cost drivers for PJI. To examine the overall cost of the treatment of PJI and to identify factors associated with management costs. The costs of treatment of prosthetic joint infections were examined in 139 patients across 10 hospitals over a 3-year period (January 2006 to December 2008). Cost calculations included hospitalization costs, surgical costs, hospital-in-the-home costs and antibiotic therapy costs. Negative binomial regression analysis was performed to model factors associated with total cost. The median cost of treating prosthetic joint infection per patient was Australian $34,800 (interquartile range: 20,305, 56,929). The following factors were associated with increased treatment costs: septic revision arthroplasty (67% increase in treatment cost; P = 0.02), hypotension at presentation (70% increase; P = 0.03), polymicrobial infections (41% increase; P = 0.009), surgical treatment with one-stage exchange (100% increase; P = 0.002) or resection arthroplasty (48% increase; P = 0.001) were independently associated with increased treatment costs. Culture-negative prosthetic joint infections were associated with decreased costs (29% decrease in treatment cost; P = 0.047). Treatment failure was associated with 156% increase in treatment costs. This study identifies clinically important factors influencing treatment costs that may be of relevance to policy-makers, particularly in the setting of hospital reimbursement and guiding future research into cost-effective preventive strategies. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    Science.gov (United States)

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  9. Prosthetic Leg Control in the Nullspace of Human Interaction.

    Science.gov (United States)

    Gregg, Robert D; Martin, Anne E

    2016-07-01

    Recent work has extended the control method of virtual constraints, originally developed for autonomous walking robots, to powered prosthetic legs for lower-limb amputees. Virtual constraints define desired joint patterns as functions of a mechanical phasing variable, which are typically enforced by torque control laws that linearize the output dynamics associated with the virtual constraints. However, the output dynamics of a powered prosthetic leg generally depend on the human interaction forces, which must be measured and canceled by the feedback linearizing control law. This feedback requires expensive multi-axis load cells, and actively canceling the interaction forces may minimize the human's influence over the prosthesis. To address these limitations, this paper proposes a method for projecting virtual constraints into the nullspace of the human interaction terms in the output dynamics. The projected virtual constraints naturally render the output dynamics invariant with respect to the human interaction forces, which instead enter into the internal dynamics of the partially linearized prosthetic system. This method is illustrated with simulations of a transfemoral amputee model walking with a powered knee-ankle prosthesis that is controlled via virtual constraints with and without the proposed projection.

  10. Ergonomic workplace assessment in orthotic and prosthetic workshops.

    Science.gov (United States)

    Salmani Nodooshan, H; Koohi Booshehri, S; Daneshmandi, H; Choobineh, A R

    2016-10-17

    In Iranian orthotic and prosthetic workshops, the majority of activities are carried out by manpower and the tasks are labor-intensive. In these workshops, ergonomic aspects of working conditions are seldom considered. This study was conducted in orthotic and prosthetic workshops with the objectives of determination of prevalence rate of MSDs among employees and assessment of ergonomics working conditions. In this cross-sectional study, all employees (n = 42; 29 males and 13 females) in 11 active orthotic and prosthetic production centers of Shiraz city participated. Data were collected using Nordic Musculoskeletal disorders Questionnaire (NMQ) and observational technique by an ergonomics checklist for assessment of working conditions. The means (SD) of age and job tenure (years) in the study individuals were 37.26 (10.21) and 12.8 (9.39), respectively. The most prevalent MSD symptoms in the past 12 months were reported in the lower back (42.9%), shoulders (40.5%) and knees (40.5%). Working conditions assessment showed that the main ergonomic problems in the workshops studied originated from awkward working posture, improper workstation design, poorly designed hand tools and incorrect manual material handling. Any interventional program for working conditions improvement should, therefore, focus on these areas.

  11. The relevance of aortic endograft prosthetic infection

    NARCIS (Netherlands)

    Cernohorsky, Paul; Reijnen, Michel M. P. J.; Tielliu, Ignace F. J.; van Sterkenburg, Steven M. M.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General treatment consensus with infected graft material is that it should be removed completely. The objective of this study was to describe the

  12. Good quality of life outcomes after treatment of prosthetic joint infection with debridement and prosthesis retention.

    Science.gov (United States)

    Aboltins, Craig; Dowsey, Michelle; Peel, Trish; Lim, Wen K; Choong, Peter

    2016-05-01

    Patients treated for early prosthetic joint infection (PJI) with surgical debridement and prosthesis retention have a rate of successful infection eradication that is similar to patients treated with the traditional approach of prosthesis exchange. It is therefore important to consider other outcomes after prosthetic joint infection treatment that may influence management decisions, such as quality of life (QOL). Our aim was to describe infection cure rates and quality of life for patients with prosthetic joint infection treated with debridement and prosthesis retention and to determine if treatment with this approach was a risk factor for poor quality of life outcomes. Prospectively collected pre and post-arthroplasty data were available for 2,134 patients, of which PJI occurred in 41. For patients treated for prosthetic joint infection, the 2-year survival free of treatment failure was 87% (95%CI 84-89). Prosthetic joint infection cases treated with debridement and retention had a similar improvement from pre-arthroplasty to 12-months post-arthroplasty as patients without PJI in QOL according to the SF-12 survey. Prosthetic joint infection treated with debridement and retention was not a risk factor for poor quality of life on univariate or multivariate analysis. Prosthetic joint infection treated with debridement and prosthesis retention results in good cure rates and quality of life. Further studies are required that directly compare quality of life for different surgical approaches for prosthetic joint infection to better inform management decisions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:898-902, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Life and times of the impact factor: retrospective analysis of trends for seven medical journals (1994-2005) and their Editors' views

    Science.gov (United States)

    Chew, Mabel; Villanueva, Elmer V; Van Der Weyden, Martin B

    2007-01-01

    Objective (1) To analyse trends in the journal impact factor (IF) of seven general medical journals (Ann Intern Med, BMJ, CMAJ, JAMA, Lancet, Med J Aust and N Engl J Med) over 12 years; and (2) to ascertain the views of these journals' past and present Editors on factors that had affected their journals' IFs during their tenure, including direct editorial policies. Design Retrospective analysis of IF data from ISI Web of Knowledge Journal Citation Reports—Science Edition, 1994 to 2005, and interviews with Editors-in-Chief. Setting Medical journal publishing. Participants Ten Editors-in-Chief of the journals, except Med J Aust, who served between 1999 and 2004. Main outcome measures IFs and component numerator and denominator data for the seven general medical journals (1994 to 2005) were collected. IFs are calculated using the formula: (Citations in year z to articles published in years x and y)/(Number of citable articles published in years x and y), where z is the current year and x and y are the previous two years. Editors' views on factors that had affected their journals' IFs were also obtained. Results IFs generally rose over the 12-year period, with the N Engl J Med having the highest IF throughout. However, percentage rises in IF relative to the baseline year of 1994 were greatest for CMAJ (about 500%) and JAMA (260%). Numerators for most journals tended to rise over this period, while denominators tended to be stable or to fall, although not always in a linear fashion. Nine of ten eligible editors were interviewed. Possible reasons given for rises in citation counts included: active recruitment of high-impact articles by courting researchers; offering authors better services; boosting the journal's media profile; more careful article selection; and increases in article citations. Most felt that going online had not affected citations. Most had no deliberate policy to publish fewer articles (lowering the IF denominator), which was sometimes the unintended

  14. Life and times of the impact factor: retrospective analysis of trends for seven medical journals (1994-2005) and their Editors' views.

    Science.gov (United States)

    Chew, Mabel; Villanueva, Elmer V; Van Der Weyden, Martin B

    2007-03-01

    (1) To analyse trends in the journal impact factor (IF) of seven general medical journals (Ann Intern Med, BMJ, CMAJ, JAMA, Lancet, Med J Aust and N Engl J Med) over 12 years; and (2) to ascertain the views of these journals' past and present Editors on factors that had affected their journals' IFs during their tenure, including direct editorial policies. Retrospective analysis of IF data from ISI Web of Knowledge Journal Citation Reports-Science Edition, 1994 to 2005, and interviews with Editors-in-Chief. Medical journal publishing. Ten Editors-in-Chief of the journals, except Med J Aust, who served between 1999 and 2004. MAIN OUTCOME MEASURES IFs and component numerator and denominator data for the seven general medical journals (1994 to 2005) were collected. IFs are calculated using the formula: (Citations in year z to articles published in years x and y)/(Number of citable articles published in years x and y), where z is the current year and x and y are the previous two years. Editors' views on factors that had affected their journals' IFs were also obtained. IFs generally rose over the 12-year period, with the N Engl J Med having the highest IF throughout. However, percentage rises in IF relative to the baseline year of 1994 were greatest for CMAJ (about 500%) and JAMA (260%). Numerators for most journals tended to rise over this period, while denominators tended to be stable or to fall, although not always in a linear fashion. Nine of ten eligible editors were interviewed. Possible reasons given for rises in citation counts included: active recruitment of high-impact articles by courting researchers; offering authors better services; boosting the journal's media profile; more careful article selection; and increases in article citations. Most felt that going online had not affected citations. Most had no deliberate policy to publish fewer articles (lowering the IF denominator), which was sometimes the unintended result of other editorial policies. The two

  15. Smartphones as image processing systems for prosthetic vision.

    Science.gov (United States)

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  16. ARM-based visual processing system for prosthetic vision.

    Science.gov (United States)

    Matteucci, Paul B; Byrnes-Preston, Philip; Chen, Spencer C; Lovell, Nigel H; Suaning, Gregg J

    2011-01-01

    A growing number of prosthetic devices have been shown to provide visual perception to the profoundly blind through electrical neural stimulation. These first-generation devices offer promising outcomes to those affected by degenerative disorders such as retinitis pigmentosa. Although prosthetic approaches vary in their placement of the stimulating array (visual cortex, optic-nerve, epi-retinal surface, sub-retinal surface, supra-choroidal space, etc.), most of the solutions incorporate an externally-worn device to acquire and process video to provide the implant with instructions on how to deliver electrical stimulation to the patient, in order to elicit phosphenized vision. With the significant increase in availability and performance of low power-consumption smart phone and personal device processors, the authors investigated the use of a commercially available ARM (Advanced RISC Machine) device as an externally-worn processing unit for a prosthetic neural stimulator for the retina. A 400 MHz Samsung S3C2440A ARM920T single-board computer was programmed to extract 98 values from a 1.3 Megapixel OV9650 CMOS camera using impulse, regional averaging and Gaussian sampling algorithms. Power consumption and speed of video processing were compared to results obtained to similar reported devices. The results show that by using code optimization, the system is capable of driving a 98 channel implantable device for the restoration of visual percepts to the blind.

  17. Dynamic elasticity measurement for prosthetic socket design.

    Science.gov (United States)

    Kim, Yujin; Kim, Junghoon; Son, Hyeryon; Choi, Youngjin

    2017-07-01

    The paper proposes a novel apparatus to measure the dynamic elasticity of human limb in order to help the design and fabrication of the personalized prosthetic socket. To take measurements of the dynamic elasticity, the desired force generated as an exponential chirp signal in which the frequency increases and amplitude is maintained according to time progress is applied to human limb and then the skin deformation is recorded, ultimately, to obtain the frequency response of its elasticity. It is referred to as a Dynamic Elasticity Measurement Apparatus (DEMA) in the paper. It has three core components such as linear motor to provide the desired force, loadcell to implement the force feedback control, and potentiometer to record the skin deformation. After measuring the force/deformation and calculating the dynamic elasticity of the limb, it is visualized as 3D color map model of the limb so that the entire dynamic elasticity can be shown at a glance according to the locations and frequencies. For the visualization, the dynamic elasticities measured at specific locations and frequencies are embodied using the color map into 3D limb model acquired by using 3D scanner. To demonstrate the effectiveness, the visualized dynamic elasticities are suggested as outcome of the proposed system, although we do not have any opportunity to apply the proposed system to the amputees. Ultimately, it is expected that the proposed system can be utilized to design and fabricate the personalized prosthetic socket in order for releasing the wearing pain caused by the conventional prosthetic socket.

  18. 38 CFR 17.122 - Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices...

    Science.gov (United States)

    2010-07-01

    ... of the expenses of repairs to prosthetic appliances and similar devices furnished without prior... Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices furnished without prior authorization. The expenses of repairs to prosthetic appliances, or similar appliances...

  19. Data Sharing: A New Editorial Initiative of the International Committee of Medical Journal Editors. Implications for the Editors´ Network

    NARCIS (Netherlands)

    Alfonso, Fernando; Adamyan, Karlen; Artigou, Jean-Yves; Aschermann, Michael; Boehm, Michael; Buendia, Alfonso; Chu, Pao-Hsien; Cohen, Ariel; Cas, Livio Dei; Dilic, Mirza; Doubell, Anton; Echeverri, Dario; Enç, Nuray; Ferreira-González, Ignacio; Filipiak, Krzysztof J.; Flammer, Andreas; Fleck, Eckart; Gatzov, Plamen; Ginghina, Carmen; Goncalves, Lino; Haouala, Habib; Hassanein, Mahmoud; Heusch, Gerd; Huber, Kurt; Hulín, Ivan; Ivanusa, Mario; Krittayaphong, Rungroj; Lau, Chu-Pak; Marinskis, Germanas; Mach, François; Moreira, Luiz Felipe; Nieminen, Tuomo; Oukerraj, Latifa; Perings, Stefan; Pierard, Luc; Potpara, Tatjana; Reyes-Caorsi, Walter; Rim, Se-Joong; Rødevand, Olaf; Saade, Georges; Sander, Mikael; Shlyakhto, Evgeny; Timuralp, Bilgin; Tousoulis, Dimitris; Ural, Dilek; Piek, J. J.; Varga, Albert; Lüscher, Thomas F.

    2017-01-01

    The International Committee of Medical Journal Editors (ICMJE) provides recommendations to improve the editorial standards and scientific quality of biomedical journals. These recommendations range from uniform technical requirements to more complex and elusive editorial issues including ethical

  20. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    Science.gov (United States)

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  1. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  2. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  3. EDITORIAL: Incoming Editor-in-Chief

    Science.gov (United States)

    Lidström, Suzanne

    2012-04-01

    When Professor Anders Bárány took over as the Executive Editor of Physica Scripta, in 1986, he talked of his trepidation at having to 'dress himself' in his predecessor's 'editorial coveralls'. At that time, they had been worn by Professor Nils Robert Nilsson, a major figure in the physics community, for almost 20 years. Just one year prior to this, Professor Roger Wäppling had been recruited to the position of Subeditor in conjunction with a decision to expand the number of contributions in the field of condensed matter physics, to turn it into one of the dominant subjects in the broad-based journal. Physica Scripta had already gained a reputation for being a high quality journal with wide coverage of both experimental and theoretical physics. Interestingly, in the mid 1980s, the number of papers submitted had been growing and an impressive 250 submissions per year had been attained, with all of the manuscripts being handled in-house. Not many miles away in the town of Uppsala, a group of English students was stepping off a train on a magnificent snowy day in January to embark on their final year projects. A couple of us enjoyed ourselves so much that we stayed on afterwards as PhD students, thereby encountering the mixed pleasure of studying physics in a second language for the first time. I used to copy the notes down meticulously in Swedish, then try to work backwards with a textbook to improve my language skills. One day, returning from a particularly incomprehensible lecture on solid state physics, I showed my roommates my notes and asked if they could please explain what the lecture had been about: 'I don't know', they replied, 'but this bit is about sheep!' Meanwhile, back at Physica Scripta, the journal continued to flourish: 400 submissions were received in 1996, and the march of progress was well underway. Manuscripts could now be sent in on disks and Physica Scripta was available on the World Wide Web. Roger was appointed to manage the journal and

  4. Views of Reference List Accuracy from Social Work Journal Editors and Published Authors

    Directory of Open Access Journals (Sweden)

    Scott E. Wilks

    2004-12-01

    Full Text Available Objective:The study’s purpose was to answer two research questions: (1 In the opinion of social work journal editors, how important is reference list accuracy? and (2Who is primarily responsible for the accuracy of reference lists published in social work journals? Method: A sample of 119 authors and 26 journal editors was surveyed to ascertain their views on the above questions and additional items. Results: Regarding the importance of reference list accuracy, editors’ responses (Likert scale averaged between moderately and extremely important. Fifty-three percent of responding editors and 36.5% of authors reported that responsibility is shared between the editor/staff and manuscript authors; the remaining 47% and 63.5%, respectively, responded that responsibility falls upon manuscript authors. Responses from authors, mostly educators, revealed a greater-than-moderate importance (Likert scale given to instructing students on the accurate construction of reference lists. Implications for social work education and journal publishing are discussed.

  5. Changes in Editorial board Rhinology, Prof. Valerie Lund demits office as Editor in Chief of Rhinology

    NARCIS (Netherlands)

    Fokkens, W. J.

    2014-01-01

    At the Editorial Board Meeting of Rhinology Valerie Lund indicated that she has decided to emit office as Editor in Chief of Rhinology. She became a member of the editorial board in 1993, a co-editor with Prof. Bert Huizing in 1999 and Editor in Chief in 2004. She leaves with our grateful thanks for

  6. IMPLEMENTASI EDITOR MODEL DATA KONSEPTUAL DAN MODEL DATA FISIK DENGAN ROUND-TRIP ENGINEERING

    Directory of Open Access Journals (Sweden)

    Aldy Sefan Rezanaldy

    2012-01-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Desain model basis data merupakan sebuah fase penting dalam pengembangan sebuah Aplikasi Sistem Informasi. Editor Model Data yang digunakan untuk melakukan desain basis data sangat diperlukan dalam dunia IT. Sebagian Editor yang ada saat ini belum menerapkan konsep round-trip engineering secara real time, sehingga perubahan yang terjadi pada satu data model membutuhkan event update untuk melakukan pembaharuan pada model data yang lainnya. Editor model data ini merupakan editor dengan round-trip engineering. Konversi bolak-balik dilakukan antara data model konseptual dan data model fisik. Editor ini dikembangkan dengan menggunakan C# .NET Framework dan implementasi desain pola pada Object Oriented. Dalam implementasi sebuah editor, yang merupakan bagian terpenting selain berjalannya seluruh fitur yang ada adalah tentang performa dan kenyamanan user ketika menggunakannya. Performa dan kenyamanan user menjadi penilaian tersendiri pada sebuah editor model data. Aplikasi yang dihasilkan diharapkan dapat digunakan untuk melakukan desain basis data dengan menerapkan metode konversi bolak-balik, sehingga tidak diperlukan proses perbaruan dari model data yang satu ke model data yang lain secara manual. Diharapkan dapat

  7. CRITERIA FOR THE EVALUATION AND ESTIMATION OF IATROGENIC PROSTHETIC FACTORS – SEMIOLOGY AND SYMPTOMATOLOGY

    Directory of Open Access Journals (Sweden)

    G. LUCA

    2013-12-01

    Full Text Available Introduction: The principles lying at the basis of a balanced dental occlusion cannot be analyzed separately, but only if considering the teeth (and, implicitly, dental occlusion as integrated into the masticatory system, which includes the masticatory muscles, the temporo-mandibu‑ lary joint and the maxillary bones. Scope: The scope of the present study was to correlate and establish the interde‑ pendence between the morpholgically-incorrect prosthetic works and the tissular and functional damages suffered by the neighbouring structures, as a result of some incor‑ rectly-made prosthetic works. Also, the study aims at iden‑ tifying the factors and limits responsible for a prolongued maintenance of such irreversible pathological modificati‑ ons within an asymptomatic zone for the patient. Materials and method: The working hypothesis of the present inves‑ tigation started from the analysis of the various objective signs, versus the morphology of the incorrectly performed prosthetic works. The study, initiated as early as 2009, in a private stomatological clinics (DentEstet, Bucuresti, includes a number of 500 patients (250 women and 250 men, selected among the patients having addressed the stomatological office from various reasons (not always related to the prosthetic pathology of the cases here under investigation. Included in the study have been only the patients with fixed prosthetic works associated with one or several of the previously described objective signs, potentially induced by the iatrogeneicity of the prosthetic works. Results: The pathological effects of the iatrogenic works here under analysis, upon both the antagonistic and prosthetic support teeth, may be clinically identified during a minute examination performed prior to produ‑ cing irreversible final effects (abrasions, fractures, dental mobility, etc.. Such noxious effects of the iatrogenic pros‑ thetic works appear as a false masticatory comfort and as a

  8. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    Science.gov (United States)

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  9. Prosthetics & Orthotics Manufacturing Initiative (POMI)

    Science.gov (United States)

    2012-12-21

    suspension system, socket- ankle /knee interface, etc.) associated with a complete prosthetic system. More specific, the purpose of these deliverables was...strap. The waist belt consists of an adjustable belt utilizing polypropylene buckles and a 2‖ elastic suspension strap which descends to the anchor ...Superior View. Step 8: The suspension component consists of a 1’ anchor strap with a buckle and a 5’ – 6’ long shoulder strap with hook and

  10. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    Science.gov (United States)

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  11. Ethical dilemmas in scientific publication: pitfalls and solutions for editors Dilemas éticos na publicação científica: dificuldades e soluções para editores

    Directory of Open Access Journals (Sweden)

    Laragh Gollogly

    2006-08-01

    Full Text Available Editors of scientific journals need to be conversant with the mechanisms by which scientific misconduct is amplified by publication practices. This paper provides definitions, ways to document the extent of the problem, and examples of editorial attempts to counter fraud. Fabrication, falsification, duplication, ghost authorship, gift authorship, lack of ethics approval, non-disclosure, 'salami' publication, conflicts of interest, auto-citation, duplicate submission, duplicate publications, and plagiarism are common problems. Editorial misconduct includes failure to observe due process, undue delay in reaching decisions and communicating these to authors, inappropriate review procedures, and confounding a journal's content with its advertising or promotional potential. Editors also can be admonished by their peers for failure to investigate suspected misconduct, failure to retract when indicated, and failure to abide voluntarily by the six main sources of relevant international guidelines on research, its reporting and editorial practice. Editors are in a good position to promulgate reasonable standards of practice, and can start by using consensus guidelines on publication ethics to state explicitly how their journals function. Reviewers, editors, authors and readers all then have a better chance to understand, and abide by, the rules of publishing.Editores de revistas científicas precisam estar atentos aos mecanismos de disseminação de condutas inadequadas no processo de publicação. Este artigo fornece definições, formas de documentar a extensão do problema e exemplos de iniciativas para conter fraudes editorias. Fabricação, falsificação, duplicação, autoria-fantasma, autoria concedida, falta de ética na aprovação de manuscritos, não-divulgação desses fatos, publicação "salami", conflitos de interesse, autocitação, submissão e publicação duplicadas, e plágio são problemas comuns. A conduta editorial inadequada

  12. Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

    Science.gov (United States)

    Roberson, Luke Bennett

    2014-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

  13. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  14. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  15. Consumer satisfaction in prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Geertzen, J.H.B.; Gankema, H.G.J.; Groothoff, J.W.; Dijkstra, P.U.

    The aim of this study was to assess consumer/patient satisfaction with the services of the prosthetics and orthotics (P&O) facilities in the north of the Netherlands, using a modified SERVQUAL questionnaire. In this questionnaire, consumer interests and experiences are assessed on a 5-point Likert

  16. Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

    Science.gov (United States)

    Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R

    2012-11-01

    Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also

  17. Prosthetic valve obstruction: Redo surgery or fibrinolysis?

    Directory of Open Access Journals (Sweden)

    Avinash Inamdar

    2017-01-01

    Full Text Available Objective: The aim of this study was to compare the efficacy and safety of surgery versus fibrinolytic therapy in patients with prosthetic valve obstruction. Materials and Methods: We compared 15 patients of prosthetic valve thrombosis treated by surgical line of management and another 15 patients treated by thrombolysis. All patients were initially assessed by clinical evaluation and diagnosis confirmed by transthoracic and transesophageal two-dimensional echocardiography. Depending on hemodynamic stability, pannus, or thrombus on transesophageal echocardiography, the patients were assigned surgical or medical line of management. Results: Patients mortality rate was 40% in fibrinolytic group and 13.33% in surgical group. Recurrence was 40% in fibrinolytic group while there was no recurrence till date in surgery group. Complications were more in fibrinolytic group as opposed to surgery group patient. Conclusion: From our experience, we conclude that redo surgery is effective and definitive treatment, especially in patients with stable hemodynamic conditions.

  18. Self-cleaning skin-like prosthetic polymer surfaces

    Science.gov (United States)

    Simpson, John T [Clinton, TN; Ivanov, Ilia N [Knoxville, TN; Shibata, Jason [Manhattan Beach, CA

    2012-03-27

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

  19. Is the Prosthetic Homologue Necessary for Embodiment?

    Science.gov (United States)

    Dornfeld, Chelsea; Swanston, Michelle; Cassella, Joseph; Beasley, Casey; Green, Jacob; Moshayev, Yonatan; Wininger, Michael

    2016-01-01

    Embodiment is the process by which patients with limb loss come to accept their peripheral device as a natural extension of self. However, there is little guidance as to how exacting the prosthesis must be in order for embodiment to take place: is it necessary for the prosthetic hand to look just like the absent hand? Here, we describe a protocol for testing whether an individual would select a hand that looks like their own from among a selection of five hands, and whether the hand selection (regardless of homology) is consistent across multiple exposures to the same (but reordered) set of candidate hands. Pilot results using healthy volunteers reveals that hand selection is only modestly consistent, and that selection of the prosthetic homologue is atypical (61 of 192 total exposures). Our protocol can be executed in minutes, and makes use of readily available equipment and softwares. We present both a face-to-face and a virtual protocol, for maximum flexibility of implementation.

  20. An evaluation of prosthetic status and treatment needs among institutionalized elderly individuals of Delhi, India

    OpenAIRE

    Nisha Yadav; Roma Yadav; Meetika Pahuja; Sanchit Pardhan; Sahiba Miglani; Tamanna Malik

    2017-01-01

    Context: Oral health is essential for elderly person's general health and well-being. The most common oral problem in elderly is tooth loss which results due to periodontal diseases and caries. Prosthetic status is very important as it is related to dietary intake and maintaining nutritional status. Hence, to promote the oral health of the elderly, we need to know their prosthetic status and need. Aims: The aim of this study is to find the prosthetic status and need of 65–74 years old elderly...

  1. Smart Prosthetic Hand Technology - Phase 2

    Science.gov (United States)

    2011-05-01

    functional magnetic resonance imaging (f- MRI ) was used to analyze the reciprocal adaptation between the human brain and the prosthetic hand by the...Schmidt PC. Influence of compacted hydrophobic and hydrophilic colloidal silicon dioxide on tableting properties of pharmaceutical excipients. Drug Dev...nanoparticles, and manganese nanoparticles) in magnetic resonance imaging ( MRI ) in the detection and staging of cancer [2]. 2.1 Iron Oxide

  2. Immediate effects of a new microprocessor-controlled prosthetic knee joint: a comparative biomechanical evaluation.

    Science.gov (United States)

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-03-01

    To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and

  3. Prosthetic joint infection caused by Pasteurella multocida: a case series and review of literature.

    Science.gov (United States)

    Honnorat, Estelle; Seng, Piseth; Savini, Hélène; Pinelli, Pierre-Olivier; Simon, Fabrice; Stein, Andreas

    2016-08-20

    Pasteurella multocida is a well-recognized zoonotic agent following dog or cat bites or scratches. Nevertheless, prosthetic joint infection caused by P. multocida are rarely reported. We report here a series of six cases of prosthetic joint infection caused by P. multocida managed at a referral centre for the treatment of bone and joint infection in southern France. We also reviewed the 26 cases reported in literature. The mean age of our cases was 74 years [±8.2, range 63-85]. In majority of our cases (5 cases) were associated with knee prostheses and one case with a hip prosthesis. Most of cases occurred after cat or dog scratches or licks or contact. Diagnoses of prosthetic joint infection caused by P. multocida were made by positive cultures of surgical biopsies or needle aspiration. Mean time delay between prosthetic joint implantation and infection onset was 7.6 years (±5.12 years, range 2-17). Local inflammation, which occurred in all six cases, was the most frequent clinical symptom, followed by pain in five cases, fever and swollen joints in four cases, and a fistula with purulent discharge inside the wound in two cases. The mean time of antibiotic therapy was 8 months. Surgical treatment with prosthesis removal was performed in three cases. Six of our cases were in remission without apparent relapse at 3 years after end of treatment. Prosthetic joint infections caused by P. multocida usually occur after animal scratches or bites, but can occasionally occur after a short animal lick. These infections are usually resulting from a contiguous infection and localized in the knee. An early antibiotic therapy after surgical debridement could avoid prosthetic withdrawal, notably in elderly patients. Patients with prosthetic joints should be warned that animals are potential sources of serious infection and urgent medical advice should be sought if they are bitten or scratched.

  4. Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking.

    Science.gov (United States)

    Zelik, Karl E; Collins, Steven H; Adamczyk, Peter G; Segal, Ava D; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Czerniecki, Joseph M; Kuo, Arthur D

    2011-08-01

    Lower-limb amputees expend more energy to walk than non-amputees and have an elevated risk of secondary disabilities. Insufficient push-off by the prosthetic foot may be a contributing factor. We aimed to systematically study the effect of prosthetic foot mechanics on gait, to gain insight into fundamental prosthetic design principles. We varied a single parameter in isolation, the energy-storing spring in a prototype prosthetic foot, the controlled energy storage and return (CESR) foot, and observed the effect on gait. Subjects walked on the CESR foot with three different springs. We performed parallel studies on amputees and on non-amputees wearing prosthetic simulators. In both groups, spring characteristics similarly affected ankle and body center-of-mass (COM) mechanics and metabolic cost. Softer springs led to greater energy storage, energy return, and prosthetic limb COM push-off work. But metabolic energy expenditure was lowest with a spring of intermediate stiffness, suggesting biomechanical disadvantages to the softest spring despite its greater push-off. Disadvantages of the softest spring may include excessive heel displacements and COM collision losses. We also observed some differences in joint kinetics between amputees and non-amputees walking on the prototype foot. During prosthetic push-off, amputees exhibited reduced energy transfer from the prosthesis to the COM along with increased hip work, perhaps due to greater energy dissipation at the knee. Nevertheless, the results indicate that spring compliance can contribute to push-off, but with biomechanical trade-offs that limit the degree to which greater push-off might improve walking economy. © 2011 IEEE

  5. Editor for Remote Database used in ATLAS Trigger/DAQ

    CERN Document Server

    Meessen, C; Valenta, J

    2006-01-01

    The poster gives brief summary of the ATLAS T/DAQ system, then it introduces the RDB database and describes the RDB Editor application, including its internal structure, GUI features, etc. The RDB Editor is an easy-to-use Java application which allows simple navigation between huge number of objects stored in the RDB. It supports bookmarks, histories, etc. in the way usual in the web browsers. Moreover, it is possible to enhance the application by specialized (graphical) viewers for objects of particular class which will allow the user to see, for example, details that are hard to spot in textual view. As an example of such a plug-in, viewer for EFD_Configuration class was developed.

  6. The Prosthetic Experience Between Body and Technology

    DEFF Research Database (Denmark)

    Søndergaard, Morten

    2018-01-01

    In this paper, I argue that a prosthetic aesthetic instigated by experimental art practices operate with and within a ‘second nature’ – in-between science and art. Drawing on theories from Dewey and Edelman and examples from Da Vinci, Brancusi, Man Ray, Dali and Stelarc, I am calling...

  7. Aortic allografts in treatment of aortic valve and ascending aorta prosthetic endocarditis

    Directory of Open Access Journals (Sweden)

    S.V. Spiridonov

    2017-03-01

    Full Text Available The aim – to assess short- and long-term results of aortic root replacement using aortic allografts in patients with prosthetic endocarditis. Materials and methods. Since February 2009 until June 2016 aortic valve and ascending aorta replacement using aortic allografts was performed in 26 patients with prosthetic endocarditis. In 50 % of cases at initial operation aortic valve replacement was performed, in another 50 % of cases – aortic valve and ascending aorta replacement. Echocardiography was performed 10 days, 3, 6 and 12 months, 2, 3 and 5 years after surgery. Analysis of long-term results included all cases of deaths, prosthesis-related complications and recurrence of endocarditis. Results. 30-day mortality was 23.1 %. Extracorporeal membranous oxygenation (ECMO was used only in 5 patients (19.2 %. Four patients were weaned from ECMO. We did not observe any allograft-related complications. During follow-up period there were no cases of reoperation due to structural allograft failure. Relapse of infection occurred in 1 patient (3.8 % four years after the operation and led to lethal outcome. Conclusion. Reoperations using allografts are an effective surgical treatment of prosthetic endocarditis. In majority of cases prosthetic endocarditis was caused by gram-positive cocci (Staphylococcus. In 84.6 % of cases it was associated with destruction of paravalvular structures and abscesses formation. Heart failure was a causative factor of different complications in these patients, which required ECMO in 19.2 % of patients. In 80 % of cases patients were weaned from ECMO. Allografts using for the treatment of prosthetic endocarditis is associated with high resistance to infection and with a significant rate of freedom from recurrence of endocarditis within 3 years after surgery.

  8. Selected applications for current polymers in prosthetic dentistry - state of the art.

    Science.gov (United States)

    Kawala, Maciej; Smardz, Joanna; Adamczyk, Lukasz; Grychowska, Natalia; Wieckiewicz, Mieszko

    2018-05-10

    Polymers are widely applied in medicine, including dentistry, i.e. in prosthodontics. The following paper is aimed at demonstrating the applications of selected modern polymers in prosthetic dentistry based on the reported literature. The study was conducted using the PubMed, SCOPUS and CINAHL databases in relation to documents published during 1999-2017. The following keywords were used: polymers with: prosthetic dentistry, impression materials, denture base materials, bite registration materials, denture soft liners, occlusal splint materials and 3D printing. Original papers and reviews which were significant from the modern clinical viewpoint and practical validity in relation to the possibility of using polymeric materials in prosthetic dentistry, were presented. Denture base materials were most commonly modified polymers. Modifications mainly concerned antimicrobial properties and reinforcement of the material structure by introducing additional fibers. Antimicrobial modifications were also common in case of relining materials. Polymeric materials have widely been used in prosthetic dentistry. Modifications of their composition allow achieving new, beneficial properties that affect quality of patients' life. Progress in science allows for a more methodologically-advanced research on the synthesis of new polymeric materials and incorporation of new substances into already known polymeric materials, that will require systematization and appropriate classification. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Characterization of microbes in prosthetic joint specimens by culture-independent molecular methods

    DEFF Research Database (Denmark)

    Xu, Yijuan; Rudkjøbing, Vibeke Børsholt; Simonsen, Ole

    Prosthetic joint infection (PJI) is one of the most challenging complications of joint alloplasty. Formation of biofilm is a prominent feature of PJIs and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study was to inves......Prosthetic joint infection (PJI) is one of the most challenging complications of joint alloplasty. Formation of biofilm is a prominent feature of PJIs and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study...... was to investigate the microbial diversity in surgical samples (eg. synovial fluid, periprosthetic tissue, removed prosthesis) from 22 prosthetic patients using a range of culture-independent molecular methods including broad range 16S rRNA gene PCR, cloning, phylogeny, quantitative PCR (qPCR), and fluorescence...

  10. Writing GNU Emacs Extensions Editor Customizations and Creations with Lisp

    CERN Document Server

    Glickstein, Bob

    2010-01-01

    Yes, it is possible to be all things to all people, if you're talking about the Emacs editor. As a user, you can make any kind of customization you want, from choosing the keystrokes that invoke your favorite commands to creating a whole new work environment that looks like nothing ever developed before. It's all in Emacs Lisp -- and in this short but fast-paced book. GNU Emacs is more than an editor; it's a programming environment, a communications package, and many other things. To provide such a broad range of functions, it offers a full version of the Lisp programming language

  11. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. FloorspaceJS - A New, Open Source, Web-Based Geometry Editor for Building Energy Modeling (BEM): Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Macumber, Daniel L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Horowitz, Scott G [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schott, Marjorie [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Nolan, Katie [Devetry; Schiller, Brian [Devetry

    2018-03-19

    Across most industries, desktop applications are being rapidly migrated to web applications for a variety of reasons. Web applications are inherently cross platform, mobile, and easier to distribute than desktop applications. Fueling this trend are a wide range of free, open source libraries and frameworks that make it incredibly easy to develop powerful web applications. The building energy modeling community is just beginning to pick up on these larger trends, with a small but growing number of building energy modeling applications starting on or moving to the web. This paper presents a new, open source, web based geometry editor for Building Energy Modeling (BEM). The editor is written completely in JavaScript and runs in a modern web browser. The editor works on a custom JSON file format and is designed to be integrated into a variety of web and desktop applications. The web based editor is available to use as a standalone web application at: https://nrel.github.io/openstudio-geometry-editor/. An example integration is demonstrated with the OpenStudio desktop application. Finally, the editor can be easily integrated with a wide range of possible building energy modeling web applications.

  13. Magazine Editors and the Writing Process: An Analysis of How Editors Work with Staff and Free-Lance Writers.

    Science.gov (United States)

    Schierhorn, Ann B.; Endres, Kathleen L.

    Editors of business and consumer magazines chosen by a random sample were asked in a mail survey what method they used in working with staff writers and free-lance writers. They were asked how they work with writers in the five stages of the writing process--idea, reporting, organizing, writing and rewriting. The first mailing to consumer…

  14. Nitinol for Prosthetic and Orthotic Applications

    Science.gov (United States)

    Henderson, Emma; Buis, Arjan

    2011-07-01

    As global populations age, conditions such as stroke and diabetes require individuals to use rehabilitation technology for many years to come due to chronic musculoskeletal, sensory, and other physical impairments. One in four males currently aged 45 will experience a stroke within 40 years and will often require access to prolonged rehabilitation. In addition, worldwide, one individual loses a limb every 30 s due to the complications of diabetes. As a result, innovative ideas are required to devise more effective prosthetic and orthotic devices to enhance quality of life. While Nitinol has already found much favor within the biomedical industry, one area, which has not yet exploited its unique properties, is in the field of physical rehabilitation, ranging from prosthetic and orthotic devices to assistive technology such as wheelchairs. Improved intervention capabilities based on materials such as Nitinol have the potential to vastly improve patients' quality of life and in the case of orthoses, may even reduce the severity of the condition over time. It is hoped that this study will spark discussion and interest for the materials community in a field which has yet to be fully exploited.

  15. Message from the Editor

    Science.gov (United States)

    Stambaugh, Ronald D.

    2014-01-01

    This last year being an odd numbered year, the pages of Nuclear Fusion saw a large influx of expanded papers from the 2012 Fusion Energy Conference in San Diego. Many papers have focused on the scientific and technical challenges posed by ITER. Contributions are steadily increasing from the new superconducting tokamaks in Asia. The ITER Project continues to move ahead. Construction at the Cadarache site is quite remarkable. Buildings completed include the huge Poloidal Field Coils Winding Facility and the Headquarters building, which has been occupied by the ITER staff. Work is progressing on the Assembly building and the Cryostat Workshop. The base of the tokamak complex is being laid. Besides the construction that is taking place and will take place at the site, components from around the world have to navigate the complex route from Marseilles to the site. A test convoy replicating the dimensions and weights of the most exceptional ITER loads successfully traversed that route in 2013. We are pleased to report that the IAEA and ITER have finalized the agreement for ITER authors to publish papers in Nuclear Fusion . Nuclear Fusion is proud to continue its key role in providing the leading forum for the documentation of scientific progress and exchange of research results internationally toward fusion energy. Refereeing The Nuclear Fusion editorial office appreciates greatly the effort made by our referees to sustain the high quality of the journal. Since January 2005, we have been offering the most active referees over the past year a personal subscription to Nuclear Fusion with electronic access for one year, free of charge. We have excluded our Board Members, Guest Editors of special editions and those referees who were already listed in previous years. The following people have been selected: J.M. Canik, Oak Ridge National Laboratory, USA I.T. Chapman, Culham Centre for Fusion Energy, UK L.-G. Eriksson, Commission of the European Communities, Belgium T. Evans

  16. EDITORIAL: A word from the new Editor-in-Chief A word from the new Editor-in-Chief

    Science.gov (United States)

    Mostowski, Jan

    2011-01-01

    TIn the autumn of 2010 I became the Editor-in Chief of European Journal of Physics (EJP). EJP is a place for teachers, instructors and professors to exchange their views on teaching physics at university level and share their experience. It is general opinion that no good research is possible without connection with good, high-quality teaching, at the university level in particular. Therefore excellence in physics teaching is important to the physics community. European Journal of Physics is proud of its contribution to achieving this goal. As Editor-in-Chief, I will continue to work to this general objective of the journal. We will publish articles on specific topics in physics, stressing originality of presentation and suitability for use in students'laboratories, lectures and physics teaching in general. We will also publish more pedagogical papers presenting the achievements of particular teaching methods. In addition, we will continue to publish special sections on particular areas of physics, as well as the annual special section on physics competitions. European Journal of Physics is in good shape. Due to the work of the previous editors and the publisher, the readership is high and growing steadily, and many excellent papers are being submitted and published. I hope that this positive trend for the journal will continue, and I will do my best to keep to this high standard. A few words about myself. I work in the Institute of Physics in Warsaw, Poland. My main research interests are in theoretical quantum optics and I have published about 80 research papers on this topic. For many years I was involved in teaching physics at university and in high school. I am a co-author of a textbook on physics for high-school students and of a problem book in quantum mechanics. For the last ten years, I have been involved in the International Physics Olympiad and over the last few years I have been a member of the Editorial Board of European Journal of Physics.

  17. A survey of prosthetic eye wearers to investigate mucoid discharge

    Directory of Open Access Journals (Sweden)

    Pine K

    2012-05-01

    Full Text Available Keith Pine1, Brian Sloan2, Joanna Stewart3, Robert J Jacobs11Department of Optometry and Vision Science, 2Department of Ophthalmology, New Zealand National Eye Centre, 3Section of Epidemiology and Biostatistics, School of Population Health, University of Auckland, Auckland, New ZealandBackground: This study aimed to better understand the causes and treatments of mucoid discharge associated with prosthetic eye wear by reviewing the literature and surveying anophthalmic patients.Methods: An anonymous questionnaire was completed by 429 prosthetic eye wearers who used visual analog scales to self-measure their discharge experience for four discharge characteristics: frequency, color, volume, and viscosity. These characteristics were analyzed with age, ethnicity, years wearing a prosthesis, eye loss cause, removal and cleaning regimes, hand-washing behavior, age of current prosthesis, and professional repolishing regimes as explanatory variables. Eighteen ocularists’ Web sites containing comments on the cause and treatment of discharge were surveyed.Results: Associations were found between discharge frequency and cleaning regimes with more frequent cleaning accompanying more frequent discharge. Color was associated with years of wearing and age, with more years of wearing and older people having less colored discharge. Volume was associated with cleaning regimes with more frequent cleaners having more volume. Viscosity was associated with cleaning regimes and years of wearing with more frequent cleaning and shorter wearing time accompanying more viscous discharge. No associations were found between discharge characteristics and ethnicity, eye loss cause, hand washing, age of current prosthesis, or repolishing regimes. Forty-seven percent of ocularists’ Web sites advised that discharge was caused by surface deposits on the prosthesis, 29% by excessive handling of the prosthesis, and 24% by other causes.Conclusions: A standardized treatment

  18. Roles and responsibilities of the special-section editor

    KAUST Repository

    Marfurt, Kurt

    2017-10-19

    professionals to demonstrate that value in action. Other advantages include the perspectives provided by such special-section authors, editors, and reviewers that draw in a diverse suite of geoscientists and engineers that truly represent the interpretation community. Where there are advantages, there are also disadvantages. First, the vast majority of special-section editors are “new to the job,” never having served on an editorial board of a peer-reviewed scientific journal. The primary objective of this “From the Editor” note is to clarify the roles and responsibilities of this task. Second, many of the selected reviewers may never have had the opportunity to review a paper for publication. They too are new to the job. The August issue of the From the Editor column (Bui et al., 2017) titled “Qualities of a good reviewer” directly addresses this challenge. In this article, we encourage the reviewers to help the authors to construct a quality, well-referenced paper because many of them, too, are new to the job. The third disadvantage is that the special-section format skews the citation-index metrics. Obviously, if the special-section editors identify a good oral presentation and request the author to develop a full-length paper, the chances of acceptance are higher, thus lowering the citation index score. More on this conundrum will be found in the From the Editor column in the February 2018 issue of Interpretation. The remainder of this short article addresses the issues specific to the special-section editors.

  19. EDITORIAL: Greetings from the new Editor-in-Chief

    Science.gov (United States)

    Bhattacharya, P.

    2004-04-01

    On 1 January, 2004, I assumed the position of Editor-in-Chief of Journal of Physics D: Applied Physics. I will start by saying that I will do my best to justify the confidence of the journal management and publishing staff in my abilities. I was fortunate to have been able to work, as an Editorial Board member, with my predecessor, the previous Editor-in-Chief, Professor Allister Ferguson. Allister has provided a high degree of intellectual stewardship for the journal in the last five years. He has made the job appear a worthy challenge for me. I therefore take this opportunity to thank Allister on behalf of the Editorial Board and publishing staff of the journal. Several other factors contributed to my decision to accept this position. The first is the group of people who actually go about the business of publishing. The Senior Publisher, Nicola Gulley (and her predecessor Sophy Le Masurier); the Managing Editor, Jill Membrey; the Publishing Administrators, Nina Blakesley and Sarah Towell; the Production Editor, Katie Gerrard and their office staff form an amazing group and have managed to make the operation of the journal incredibly efficient. An index of this is the speed with which incoming manuscripts are processed. The average time between the receipt of a manuscript and its web publication, if accepted, is 130 days. This is three to five times shorter than for most other journals. A factor that contributes to this success is a responsive pool of referees that the publishing staff have as a valuable resource. Ultimately, the standard bearers of any journal are the referees. Therefore, a grateful `thank you' is due from all of us at J. Phys. D to all our referees, who diligently perform this honourable task. The Associate Editors of the journal, Professors Lawler, Margaritondo and O'Grady, also provide immense scientific leadership. They help in defining new directions for the journal and in the publishing process. Last, but not least, a remarkable asset of

  20. Editorial: Letter from the Editors

    Directory of Open Access Journals (Sweden)

    James Sidanius

    2012-12-01

    Full Text Available This issue of the journal focuses on the question of bullying prevention, with a collection of articles put together by Manuel Eisner and Tina Malti. We are very grateful to them for the hard work they put in as focus section editors – and in their contributions to the section. The open section this time takes us to North America for a study of identity and in-group superiority and Africa for a review of the question of youth and violence.

  1. Prosthetic management of an ocular defect

    Directory of Open Access Journals (Sweden)

    Siddesh Kumar Chintal

    2010-01-01

    Full Text Available The disfigurement associated with the loss of an eye can cause significant physical and emotional problems. Various treatment modalities are available, one of which is implants. Although implant has a superior outcome, it may not be advisable in all patients due to economic factors. The present article describes the prosthetic management of an ocular defect with a custom-made ocular prosthesis.

  2. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    NARCIS (Netherlands)

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  3. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  4. Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update

    Science.gov (United States)

    Musso, Maria; Petrosillo, Nicola

    2015-01-01

    Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043

  5. The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation.

    Science.gov (United States)

    Segal, Ava D; Zelik, Karl E; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Adamczyk, Peter G; Collins, Steven H; Kuo, Arthur D; Czerniecki, Joseph M

    2012-08-01

    The lack of functional ankle musculature in lower limb amputees contributes to the reduced prosthetic ankle push-off, compensations at other joints and more energetically costly gait commonly observed in comparison to non-amputees. A variety of energy storing and return prosthetic feet have been developed to address these issues but have not been shown to sufficiently improve amputee biomechanics and energetic cost, perhaps because the timing and magnitude of energy return is not controlled. The goal of this study was to examine how a prototype microprocessor-controlled prosthetic foot designed to store some of the energy during loading and return it during push-off affects amputee gait. Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed. The CESR foot demonstrated increased energy storage during early stance, increased prosthetic foot peak push-off power and work, increased prosthetic limb center of mass (COM) push-off work and decreased intact limb COM collision work compared to CONV and PRES. The biological contribution of the positive COM work for CESR was reduced compared to CONV and PRES. However, the net metabolic cost for CESR did not change compared to CONV and increased compared to PRES, which may partially reflect the greater weight, lack of individualized size and stiffness and relatively less familiarity for CESR and CONV. Controlled energy storage and return enhanced prosthetic push-off, but requires further design modifications to improve amputee walking economy. Published by Elsevier B.V.

  6. The influence of staff training and education on prosthetic and orthotic service quality: A scoping review.

    Science.gov (United States)

    Forghany, Saeed; Sadeghi-Demneh, Ebrahim; Trinler, Ursula; Onmanee, Pornsuree; Dillon, Michael P; Baker, Richard

    2018-06-01

    Education and training in prosthetics and orthotics typically comply with International Society for Prosthetics and Orthotics standards based on three categories of prosthetic and orthotic professionals. This scoping study sought to describe the evidence base available to answer the question, How are prosthetic and orthotic services influenced by the training of staff providing them? Scoping review. A structured search of the peer-reviewed literature catalogued in major electronic databases yielded 3039 papers. Following review of title and abstract, 93 articles were considered relevant. Full-text review reduced this number to 25. Only two articles were identified as providing direct evidence of the effects of training and education on service provision. While both suggested that there was an impact, it is difficult to see how the more specific conclusions of either could be generalised. The other 23 articles provide a useful background to a range of issues including the specification of competencies that training programmes should deliver (3 articles), descriptions of a range of training programmes and the effects of training and education on student knowledge and skills. Although it is considered axiomatic, the service quality is dependent on practitioner education and training. There is insufficient evidence to establish whether levels of training and education in prosthetics and orthotics have an effect on the quality of prosthetic and orthotic services. Clinical relevance There is very little evidence about the effects of training and education of prosthetists and orthotists on service quality. While this is a somewhat negative finding, we feel that it is important to bring this to the attention of the prosthetics and orthotics community.

  7. First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand.

    Science.gov (United States)

    Pasquina, Paul F; Evangelista, Melissa; Carvalho, A J; Lockhart, Joseph; Griffin, Sarah; Nanos, George; McKay, Patricia; Hansen, Morten; Ipsen, Derek; Vandersea, James; Butkus, Josef; Miller, Matthew; Murphy, Ian; Hankin, David

    2015-04-15

    Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. Implantable Myoelectric Sensors (IMES(®)) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electro-magnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. We report the status of the first FDA-approved clinical trial of the IMES(®) System. This study is currently in progress, limiting reporting to only preliminary results. Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. The interim results of this study indicate the feasibility of utilizing IMES(®) technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Payments by US pharmaceutical and medical device manufacturers to US medical journal editors: retrospective observational study

    Science.gov (United States)

    Bell, Chaim M; Matelski, John J; Detsky, Allan S; Cram, Peter

    2017-01-01

    Objective To estimate financial payments from industry to US journal editors. Design Retrospective observational study. Setting 52 influential (high impact factor for their specialty) US medical journals from 26 specialties and US Open Payments database, 2014. Participants 713 editors at the associate level and above identified from each journal’s online masthead. Main outcome measures All general payments (eg, personal income) and research related payments from pharmaceutical and medical device manufacturers to eligible physicians in 2014. Percentages of editors receiving payments and the magnitude of such payments were compared across journals and by specialty. Journal websites were also reviewed to determine if conflict of interest policies for editors were readily accessible. Results Of 713 eligible editors, 361 (50.6%) received some (>$0) general payments in 2014, and 139 (19.5%) received research payments. The median general payment was $11 (£8; €9) (interquartile range $0-2923) and the median research payment was $0 ($0-0). The mean general payment was $28 136 (SD $415 045), and the mean research payment was $37 963 (SD $175 239). The highest median general payments were received by journal editors from endocrinology ($7207, $0-85 816), cardiology ($2664, $0-12 912), gastroenterology ($696, $0-20 002), rheumatology ($515, $0-14 280), and urology ($480, $90-669). For high impact general medicine journals, median payments were $0 ($0-14). A review of the 52 journal websites revealed that editor conflict of interest policies were readily accessible (ie, within five minutes) for 17/52 (32.7%) of journals. Conclusions Industry payments to journal editors are common and often large, particularly for certain subspecialties. Journals should consider the potential impact of such payments on public trust in published research. PMID:29074628

  9. Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

    Science.gov (United States)

    Koo, Hyun Jung; Ha, Hojin; Kang, Joon-Won; Kim, Jeong A; Song, Jae-Kwan; Kim, Hwa Jung; Lim, Tae-Hwan; Yang, Dong Hyun

    2018-02-19

    Although pannus is an important cause of prosthetic valve dysfunction, the minimum pannus size that can induce hemodynamic dysfunction has not yet been determined. This study investigated the correlation between the limitation of motion (LOM) of the prosthetic valve and pannus extent and determined the pannus extent that could induce severe aortic stenosis. This study included 49 patients who underwent mechanical aortic valve replacement (AVR) and showed pannus on cardiac computed tomography (CT). Pannus width, ratio of pannus width to valve diameter, pannus area, effective orifice area, encroachment ratio by pannus, pannus involvement angle and percent LOM of mechanical valves were evaluated on CT. Transvalvular peak velocity (TPV) and transvalvular pressure gradient (TPG) were measured by transesophageal echocardiography to determine the degree of aortic stenosis. The relationship between percent LOM of the prosthetic valve and pannus extent and the cut-off of pannus extent required to induce severe aortic stenosis were evaluated. The mean interval between AVR and pannus formation was 11 years and was longer in patients with than without severe aortic stenosis (14.0 vs. 7.3 years). On CT, the percent LOM of the prosthetic valve was significantly associated with the extent of pannus only in patients with pannus involvement angle > 180° (r = 0.55-0.68, P Pannus width, effective orifice area, and encroachment ratio were significantly associated with increased TPV and TPG (r = 0.51-0.62, P Pannus width > 3.5 mm, pannus width/valve inner diameter > 0.15, and encroachment ratio > 0.14 were significantly associated with severe aortic stenosis (TPV > 4 m/s; mean TPG ≥ 35 mmHg), with c-indices of 0.74-079 (P pannus extent parameters are good indicators of significant hemodynamic changes with increased TPV and mean TPG.

  10. An evaluation of prosthetic status and treatment needs among institutionalized elderly individuals of Delhi, India

    Directory of Open Access Journals (Sweden)

    Nisha Yadav

    2017-01-01

    Full Text Available Context: Oral health is essential for elderly person's general health and well-being. The most common oral problem in elderly is tooth loss which results due to periodontal diseases and caries. Prosthetic status is very important as it is related to dietary intake and maintaining nutritional status. Hence, to promote the oral health of the elderly, we need to know their prosthetic status and need. Aims: The aim of this study is to find the prosthetic status and need of 65–74 years old elderly residing in old age homes of Delhi, India. Settings and Design: A cross-sectional study was conducted among a total of 464 residents of 20 old age homes of Delhi, India. Material and Methods: Residents with age group of 64–75 were included in the study. The prosthetic status with treatment need was recorded using the World Health Organization Oral Health Assessment Form (1997. Statistical Analysis Used: Chi-square test and t-test were used to find significance of variables. P < 0.05 was considered significant. Results: Full removable dentures were worn by 7.30% of participants with predominance in upper arch, and one bridge was seen in 9.10% of participants with predominance in lower arch. Full removable denture was required in 25.20% of participants. Most of participants required multiunit prosthesis in both upper as well as lower arch (42.20% and 36.20%, respectively. Conclusion: The present study underlines a considerable need for dental treatment in elderly as the prosthetic status of participants was poor, and prosthetic needs were high.

  11. Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function

    Science.gov (United States)

    2017-10-01

    impact on society beyond science and technology ? Nothing to report at this time. 5. CHANGES/PROBLEMS: Changes in approach and reasons for...AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a

  12. "Clones," Codes, and Conflicts of Interest in Cartooning: Cartoonists and Editors Look at Ethics.

    Science.gov (United States)

    Riffe, Daniel; And Others

    A study examined differences between political cartoonists and op-ed page editors on both traditional ethical issues (such as conflicts of interest) and the special, style-related concerns of editorial cartoonists. Hypotheses proposed were that editors and cartoonists (1) would condemn "cloning" or copying, reflecting an ethical…

  13. Improving the quality of papers submitted to dental journals: Transcription of session for editors, associate editors, publishers and others with an interest in scientific publishing held at IADR meeting in Cape Town on Wednesday, 25 June 2014.

    Science.gov (United States)

    Eaton, Kenneth A; Giannobile, William V; Sourgen, Deborah L; Balaji, S M; Honkala, Eino; Lynch, Christopher D

    2015-08-01

    This satellite symposium was the fourth in a series for editors, publishers, reviewers and all those with an interest in scientific publishing. It was held on Wednesday 25th June 2014 at the IADR International meeting in Cape Town, South Africa. The symposium attracted more than 180 attendees. This symposium placed an emphasis on how the quality of papers submitted to dental journals could be improved. The panel included representation from editors, researchers and publishers from North America, India and the Gulf States. The symposium identified a number of challenges for editors and publishers, including the poor quality of many papers submitted to dental and other scientific journals, plagiarism, attempted duplicate publication and sometimes fraudulent results. Where possible speakers are identified by name. A subsequent symposium was held during the IADR meeting in Boston on March 11th 2015. Involvement open to editors, associate editors, publishers and others with an interest in scientific publishing. Copyright © 2015. Published by Elsevier Ltd.. All rights reserved.

  14. Authors, editors, and the signs, symptoms and causes of plagiarism

    Science.gov (United States)

    Shashok, Karen

    2011-01-01

    Plagiarism and inadequate citing appear to have reached epidemic proportions in research publication. This article discusses how plagiarism is defined and suggests some possible causes for the increase in the plagiarism disease. Most editors do not have much tolerance for text re-use with inadequate citation regardless of reasons why words are copied from other sources without correct attribution. However, there is now some awareness that re-use of words in research articles to improve the writing or “the English” (which has become a common practice) should be distinguished from intentional deceit for the purpose of stealing other authors’ ideas (which appears to remain a very rare practice). Although it has become almost as easy for editors to detect duplicate text as it is for authors to re-use text from other sources, editors often fail to consider the reasons why researchers resort to this strategy, and tend to consider any text duplication as a symptom of serious misconduct. As a result, some authors may be stigmatized unfairly by being labeled as plagiarists. The article concludes with practical advice for researchers on how to improve their writing and citing skills and thus avoid accusations of plagiarism. PMID:21957412

  15. Authors, editors, and the signs, symptoms and causes of plagiarism

    Directory of Open Access Journals (Sweden)

    Karen Shashok

    2011-01-01

    Full Text Available Plagiarism and inadequate citing appear to have reached epidemic proportions in research publication. This article discusses how plagiarism is defined and suggests some possible causes for the increase in the plagiarism disease. Most editors do not have much tolerance for text re-use with inadequate citation regardless of reasons why words are copied from other sources without correct attribution. However, there is now some awareness that re-use of words in research articles to improve the writing or "the English" (which has become a common practice should be distinguished from intentional deceit for the purpose of stealing other authors′ ideas (which appears to remain a very rare practice. Although it has become almost as easy for editors to detect duplicate text as it is for authors to re-use text from other sources, editors often fail to consider the reasons why researchers resort to this strategy, and tend to consider any text duplication as a symptom of serious misconduct. As a result, some authors may be stigmatized unfairly by being labeled as plagiarists. The article concludes with practical advice for researchers on how to improve their writing and citing skills and thus avoid accusations of plagiarism.

  16. Authors, editors, and the signs, symptoms and causes of plagiarism.

    Science.gov (United States)

    Shashok, Karen

    2011-07-01

    Plagiarism and inadequate citing appear to have reached epidemic proportions in research publication. This article discusses how plagiarism is defined and suggests some possible causes for the increase in the plagiarism disease. Most editors do not have much tolerance for text re-use with inadequate citation regardless of reasons why words are copied from other sources without correct attribution. However, there is now some awareness that re-use of words in research articles to improve the writing or "the English" (which has become a common practice) should be distinguished from intentional deceit for the purpose of stealing other authors' ideas (which appears to remain a very rare practice). Although it has become almost as easy for editors to detect duplicate text as it is for authors to re-use text from other sources, editors often fail to consider the reasons why researchers resort to this strategy, and tend to consider any text duplication as a symptom of serious misconduct. As a result, some authors may be stigmatized unfairly by being labeled as plagiarists. The article concludes with practical advice for researchers on how to improve their writing and citing skills and thus avoid accusations of plagiarism.

  17. Artificial intelligence in peer review: How can evolutionary computation support journal editors?

    OpenAIRE

    Mrowinski, Maciej J.; Fronczak, Piotr; Fronczak, Agata; Ausloos, Marcel; Nedic, Olgica

    2017-01-01

    With the volume of manuscripts submitted for publication growing every year, the deficiencies of peer review (e.g. long review times) are becoming more apparent. Editorial strategies, sets of guidelines designed to speed up the process and reduce editors' workloads, are treated as trade secrets by publishing houses and are not shared publicly. To improve the effectiveness of their strategies, editors in small publishing groups are faced with undertaking an iterative trial-and-error approach. ...

  18. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    Science.gov (United States)

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  19. Complete PCB design using OrCAD capture and PCB editor

    CERN Document Server

    Mitzner, Kraig

    2009-01-01

    This book provides instruction on how to use the OrCAD design suite to design and manufacture printed circuit boards. The primary goal is to show the reader how to design a PCB using OrCAD Capture and OrCAD Editor. Capture is used to build the schematic diagram of the circuit, and Editor is used to design the circuit board so that it can be manufactured. The book is written for both students and practicing engineers who need in-depth instruction on how to use the software, and who need background knowledge of the PCB design process. KEY FEATURES:* Beginning to end cove

  20. Letter to the Editor: Re: A Five-year Survey of Cesarean Delivery at a ...

    African Journals Online (AJOL)

    Letter to the Editor: Re: A Five-year Survey of Cesarean Delivery at a Nigerian Tertiary Hospital. VO Ajuzieogu, AO Amucheazi. Abstract. Letter to the editor - no abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Article Metrics. Metrics Loading .

  1. Can we close large prosthetic space with orthodontics?

    Science.gov (United States)

    Mesko, Mauro Elias; Skupien, Jovito Adiel; Valentini, Fernanda; Pereira-Cenci, Tatiana

    2013-01-01

    For years, the treatment for the replacement of a missing tooth was a fixed dental prosthesis. Currently, implants are indicated to replace missing teeth due to high clinical success and with the advantage of not performing preparations in the adjacent tooth. Another option for space closure is the use of orthodontics associated to miniscrews for anchorage allowing better control of the orthodontic biomechanics and especially making possible closure of larger prosthetic spaces. Thus, this article describes two cases with indications and discussion of the advantages and disadvantages of using orthodontics for prosthetic spaces closure. The cases herein presented show that it is possible to close an space when there are available teeth in the adjacent area. It can be concluded that when a malocclusion is present there will be a strong trend to indicate space closure by orthodontic movement as it preserves natural teeth and seems a more physiological approach.

  2. The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.

    Science.gov (United States)

    Perito, Paul; Wilson, Steven

    2016-04-01

    Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  3. A Control Strategy with Tactile Perception Feedback for EMG Prosthetic Hand

    Directory of Open Access Journals (Sweden)

    Changcheng Wu

    2015-01-01

    Full Text Available To improve the control effectiveness and make the prosthetic hand not only controllable but also perceivable, an EMG prosthetic hand control strategy was proposed in this paper. The control strategy consists of EMG self-learning motion recognition, backstepping controller with stiffness fuzzy observation, and force tactile representation. EMG self-learning motion recognition is used to reduce the influence on EMG signals caused by the uncertainty of the contacting position of the EMG sensors. Backstepping controller with stiffness fuzzy observation is used to realize the position control and grasp force control. Velocity proportional control in free space and grasp force tracking control in restricted space can be realized by the same controller. The force tactile representation helps the user perceive the states of the prosthetic hand. Several experiments were implemented to verify the effect of the proposed control strategy. The results indicate that the proposed strategy has effectiveness. During the experiments, the comments of the participants show that the proposed strategy is a better choice for amputees because of the improved controllability and perceptibility.

  4. (Executive Editor). Microsoft Encarta Encyclopedia Deluxe 2000 ...

    African Journals Online (AJOL)

    In this regard it can be used to search only the articles, any of the multimedia features, or all the features. The editors have retained the pinpointer's form and have also opted for the same initial-alphabetical listing of lemmas in the main display window of the pinpointer. This maintains the continuity in this line of products and.

  5. Letter from the editor

    Directory of Open Access Journals (Sweden)

    Germán A. Prieto G.

    2017-07-01

    Full Text Available On September 2017, two large earthquakes struck México. Numerous casualties and at least 40 buildings collapsed in Mexico City.   The earthquakes are explained by the tectonic setting of Central America, the Cocos plate subducts underneath the North American Plate at about 7-8 cm a year, making Mexico a seismically active region. But the two earthquakes - with hypocenter depths between 50 and 60 km – did not occur in the contact between the two tectonic plates as is usually expected, but rather within the Cocos plate as it bends downward within the mantle. Both events showed a normal faulting mechanism, and although they were widely felt, their major impact was in densely populated Mexico City, where wave amplification is expected due to the geological features of the City's soil structure.   We know that we cannot predict earthquakes, and although this is the holy-grail in seismology, it seems like we are not close to accurately predict them. Nevertheless, early warning systems have been developed in various places, including Mexico, and they were successful in issuing an alarm, although with a few seconds before the strong shaking. These developments can save lives and continue to be relevant and are likely to be implemented in other regions, including the pacific coast of the US. Another aspect that can save lives is people’s awareness. The M7.1 earthquake occurred in the afternoon of the anniversary of the 1985 Michoacan earthquake, just a couple of hours after an earthquake drill in Mexico City, so people had just recently been remained of what to do.  This most likely saved lives.   We should ask ourselves, are we prepared? Is our city prepared?     Germán Prieto Editor in Chief   Carlos A. Vargas Former Editor

  6. Menthor Editor: An Ontology-Driven Conceptual Modeling Platform

    NARCIS (Netherlands)

    Moreira, João Luiz; Sales, Tiago Prince; Guerson, John; Braga, Bernardo F.B; Brasileiro, Freddy; Sobral, Vinicius

    2016-01-01

    The lack of well-founded constructs in ontology tools can lead to the construction of non-intended models. In this demonstration we present the Menthor Editor, an ontology-driven conceptual modelling platform which incorporates the theories of the Unified Foundational Ontology (UFO). We illustrate

  7. Dose uncertainties associated with a set density override of unknown hip prosthetic composition.

    Science.gov (United States)

    Rijken, James D; Colyer, Christopher J

    2017-09-01

    The dosimetric uncertainties associated with radiotherapy through hip prostheses while overriding the implant to a set density within the TPS has not yet been reported. In this study, the uncertainty in dose within a PTV resulting from this planning choice was investigated. A set of metallic hip prosthetics (stainless steel, titanium, and two different Co-Cr-Mo alloys) were CT scanned in a water bath. Within the TPS, the prosthetic pieces were overridden to densities between 3 and 10 g/cm 3 and irradiated on a linear accelerator. Measured dose maps were compared to the TPS to determine which density was most appropriate to override each metal. This was shown to be in disagreement with the reported literature values of density which was attributed to the TPS dose calculation algorithm and total mass attenuation coefficient differences in water and metal. The dose difference was then calculated for a set density override of 6 g/cm 3 in the TPS and used to estimate the dose uncertainty beyond the prosthesis. For beams passing through an implant, the dosimetric uncertainty in regions of the PTV may be as high as 10% if the implant composition remains unknown and a set density override is used. These results highlight limitations of such assumptions and the need for careful consideration by radiation oncologist, therapist, and physics staff. © 2017 Adelaide Radiotherapy Centre. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    Science.gov (United States)

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  9. NEW EDITOR OF THE CMS BULLETIN

    CERN Multimedia

    Walter Van Doninck has been the Editor of the CMS Bulletin since 2000. The Bulletin not only helps disseminate information but also records the progress of CMS. Walter is handing over to Karl Gill. We would like to thank Walter for carrying out this task with enthusiasm and efficiency for so long. We should also thank Karl for accepting to take over and wish him well over the coming exciting period.

  10. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    Science.gov (United States)

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  11. Scientific value of systematic reviews: survey of editors of core clinical journals.

    Directory of Open Access Journals (Sweden)

    Joerg J Meerpohl

    Full Text Available BACKGROUND: Synthesizing research evidence using systematic and rigorous methods has become a key feature of evidence-based medicine and knowledge translation. Systematic reviews (SRs may or may not include a meta-analysis depending on the suitability of available data. They are often being criticised as 'secondary research' and denied the status of original research. Scientific journals play an important role in the publication process. How they appraise a given type of research influences the status of that research in the scientific community. We investigated the attitudes of editors of core clinical journals towards SRs and their value for publication. METHODS: We identified the 118 journals labelled as "core clinical journals" by the National Library of Medicine, USA in April 2009. The journals' editors were surveyed by email in 2009 and asked whether they considered SRs as original research projects; whether they published SRs; and for which section of the journal they would consider a SR manuscript. RESULTS: The editors of 65 journals (55% responded. Most respondents considered SRs to be original research (71% and almost all journals (93% published SRs. Several editors regarded the use of Cochrane methodology or a meta-analysis as quality criteria; for some respondents these criteria were premises for the consideration of SRs as original research. Journals placed SRs in various sections such as "Review" or "Feature article". Characterization of non-responding journals showed that about two thirds do publish systematic reviews. DISCUSSION: Currently, the editors of most core clinical journals consider SRs original research. Our findings are limited by a non-responder rate of 45%. Individual comments suggest that this is a grey area and attitudes differ widely. A debate about the definition of 'original research' in the context of SRs is warranted.

  12. Prosthetic Management of Patients Presenting with Juvenile ...

    African Journals Online (AJOL)

    Eighteen were referred for prosthetic replacement. Their age ranged between 18 and 36 years. A total of 24 removable partial dentures were fabricated, 17[70.8%] were kennedy class III type, of which 11[64.7%] had the bounded saddle located in the anterior segment. Majority 8[44.4%] of the patients had 2-4 teeth replaced ...

  13. From the Editor

    Directory of Open Access Journals (Sweden)

    Neven Vrček

    2014-06-01

    Full Text Available Dear authors, readers and future authors,it is my pleasure to present you the 1st number of the 38th volume of the Journal of Information and Organizational Sciences – JIOS.Please allow me one personal note. This is my last issue as an editor. I started in 2008. and it is time to make some changes. I’ll continue to act as a member of editorial board but I am handling over my editorial duty to new editor Alen Lovrenčić. It was pleasure to work with all authors, reviewers and collaborators and please continue partnership with JIOS because we have high aims which cannot be achieved without dedicated scientific community. I would also like to thank the publishing team of JIOS who helped with many operational issues especially: Bernarda Kos, Goran Hajdin and Darko Grabar. In this issue a selection of 3 original scientific papers, 1 survey paper and 1 preliminary communications has been included, all of which have undergone a rigorous double-blind review process in some cases in several rounds.The constant mission of JIOS is to cover scientific publications from broad area of information sciences and related disciplines and we continuously receive many articles in which authors strive to achieve scientific merit. Our review procedure is very strict but even when we decline papers we try to encourage authors in their future work and motivate them to give better results. That is why we maintain very good relations with our authors and we invite all of you to extend cooperation with JIOS.We hope that the variety of themes will draw the attention of researchers in different fields of information sciences and motivate potential authors to expand the Journal’s thematic scope by other themes that may be of interest to the wider ICT research community. These themes motivate us to continue our work of delivering research results to interested audience. The ICT field is changing rapidly and we are constantly searching for cutting edge articles that open

  14. Pseudotumor of the Hip due to Fungal Prosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Stefano Artiaco

    2013-01-01

    Full Text Available Pseudotumors associated with total hip arthroplasty have been associated with metal-on-metal and metal-on-polyethylene total hip arthroplasties due to a granulomatous foreign-body reaction to methyl methacrylate, polyethylene, or metal ion release, but they have not been related to prosthetic joint infections. In this paper, we report an unusual case of Candida albicans total hip arthroplasty infection, causing a large inflammatory pseudotumor of the hip joint. Fungal periprosthetic joint infections are a rare clinical entity and difficult to diagnose, and a pseudotumor may be part of their clinical presentation. They should be suspected in immunodeficient host patients when clinical symptoms of prosthetic joint infections are observed.

  15. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    Science.gov (United States)

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  16. A geometrical optimization of a magneto-rheological rotary brake in a prosthetic knee

    International Nuclear Information System (INIS)

    Gudmundsson, K H; Jonsdottir, F; Thorsteinsson, F

    2010-01-01

    Magneto-rheological (MR) fluids have been successfully introduced to prosthetic devices. One such device is a biomechanical prosthetic knee that uses MR fluids to actively control its rotary stiffness. The brake is rotational, utilizing the MR fluid in shear mode. In this study, the geometrical design of the MR brake is addressed. This includes the design of the magnetic circuit and the geometry of the fluid chamber. Mathematical models are presented that describe the rotary torque of the brake. A novel perfluorinated polyether (PFPE)-based MR fluid is introduced, whose properties are tailored for the prosthetic knee. On-state and off-state rheological measurements of the MR fluid are presented. The finite element method is used to evaluate the magnetic flux density in the MR fluid. The design is formulated as an optimization problem, aiming to maximize the braking torque. A parametric study is carried out for several design parameters. Subsequently, a multi-objective optimization problem is defined that considers three design objectives: the field-induced braking torque, the off-state rotary stiffness and the weight of the brake. Trade-offs between the three design objectives are investigated which provides a basis for informed design decisions on furthering the success of the MR prosthetic knee

  17. Prosthetic joint infection due to Lysobacter thermophilus diagnosed by 16S rRNA gene sequencing

    OpenAIRE

    B Dhawan; S Sebastian; R Malhotra; A Kapil; D Gautam

    2016-01-01

    We report the first case of prosthetic joint infection caused by Lysobacter thermophilus which was identified by 16S rRNA gene sequencing. Removal of prosthesis followed by antibiotic treatment resulted in good clinical outcome. This case illustrates the use of molecular diagnostics to detect uncommon organisms in suspected prosthetic infections.

  18. Scintigraphic detection of prosthetic joint and soft tissue sepsis secondary to tuberculosis

    International Nuclear Information System (INIS)

    Zeiger, L.S.; Watters, W.; Sherk, H.

    1984-01-01

    In a 40-year-old Hispanic woman with pain and swelling in the left knee with a prosthesis, the combination of Ga-67 citrate and Tc-99m methylene diphosphonate (MDP) scans was used to indicate that there was a septic prosthetic joint. At surgery, the joint was infected and a foreign body was found. Cultures positive for tuberculosis were found also. The presence of an incongruent Ga-67 and Tc-99m (MDP) scan pattern suggests infection of the prosthetic joint, as in the following case

  19. Prosthetic prescription in the Netherlands : an observational study

    NARCIS (Netherlands)

    van der Linde, H; Geertzen, JHB; Hofstad, CJ; Postema, K; Van Limbeek, Jacques

    2003-01-01

    Prosthetic prescription for lower limb amputees and the methodology used are primarily based on empirical knowledge. Clinical expertise plays an important role that can lead to an adequate prescription; however, a clear evidence based motivation for the choices made cannot be given. This can lead to

  20. Resource-efficient proces chains to manufacture patient-specific prosthetic fingers

    Directory of Open Access Journals (Sweden)

    Hagedorn-Hansen, D.

    2016-05-01

    Full Text Available The high cost of quality prostheses, together with the lack of trained prosthetists, makes it challenging to obtain prosthetic devices in developing communities. Modern 3D digitising techniques and additive manufacturing (AM technologies are gaining popularity in the bio-medical industry and, in the case of prosthesis production, reduce the need for a trained prosthetist. The objective of this research was to develop a new resource-efficient process chain for the manufacturing of prosthetic fingers using additive manufacturing technologies, and to compare it with the traditional (Sculptor process chain. Fused deposition modelling (FDM, open-source FDM, 3-dimensional printing (3DP, and stereolithography (SLA were evaluated in terms of their costs, time, material usage, and aesthetic quality. The surface qualities produced with the different additive manufacturing technologies were also compared. The results showed that 3DP was the preferred technology and was the best candidate for the production of prosthesis in terms of cost, quality, and time for developing communities. SLA produced the highest aesthetic quality prosthesis, but was the most expensive. It was concluded that using the additive manufacturing technology process chain to produce prosthetic fingers is faster and more cost effective than the traditional method.

  1. Simulation Techniques and Prosthetic Approach Towards Biologically Efficient Artificial Sense Organs- An Overview

    OpenAIRE

    Neogi, Biswarup; Ghosal, Soumya; Mukherjee, Soumyajit; Das, Achintya; Tibarewala, D. N.

    2011-01-01

    An overview of the applications of control theory to prosthetic sense organs including the senses of vision, taste and odor is being presented in this paper. Simulation aspect nowadays has been the centre of research in the field of prosthesis. There have been various successful applications of prosthetic organs, in case of natural biological organs dis-functioning patients. Simulation aspects and control modeling are indispensible for knowing system performance, and to generate an original a...

  2. The use of ceramic in prosthetic hip surgery. The state of the art.

    Science.gov (United States)

    Toni, A; Terzi, S; Sudanese, A; Tabarroni, M; Zappoli, F A; Stea, S; Giunti, A

    1995-01-01

    The authors review current knowledge regarding the use of ceramic materials in prosthetic hip surgery, both as constituents of prosthetic components, and as materials used to coat metallic surfaces. A review of the literature defines the advantages and disadvantages to using ceramic-polyethylene or ceramic-ceramic combinations, based on the possibility that alumina coating may favor localized bone demineralization, and on the first promising clinical results of the use of hydroxyapatite coating.

  3. From the Editor

    Directory of Open Access Journals (Sweden)

    Senar, J. C.

    2014-12-01

    Full Text Available In 2001, the Natural History Museum of Barcelona remodelled its journal Miscel·lània Zoològica as Animal Biodiversity and Conservation. One of the aims of this change was to obtain an impact factor, the index that characterises the international ranking of journals. This milestone was reached some years later, in 2012, having published 291 articles that have been cited in impact journals 1,626 times. Two of these papers have been cited more than 100 times. We are now ready to take the next step forward. Our new challenge is to increase our impact factor so that Animal Biodiversity and Conservation is comparable with prestigious international journals in the field. To meet this objective we have assembled a team of editors with international recognition, and we will continue to expand this team over time. We have sought support from the most prestigious Spanish scientific societies and three have accepted the task: the Spanish Society of Ethology, the Spanish Association of Terrestrial Ecology, and the Spanish Society of Evolutionary Biology. These societies have named thematic editors who will help us strengthen their respective disciplines. This means that we will also expand the range of fields covered in the journal in future, interpreting the expression animal biodiversity in the journal´s title in its widest sense. Another front that we have opened to boost Animal Biodiversity and Conservation is the new webpage, remodelled for use as a medium to post our published papers. With this move we not only hope to improve our services to readers but also look towards open access, open access in its broadest conception, offering the journal to scientists, both readers and authors, free of charge. If we want science and the knowledge it generates —produced with public money— to belong to us all, we not only have to enable everyone to read it but we also have to help everyone publish, independently of their economic state. These are difficult

  4. Indium-granulocyte scanning in the painful prosthetic joint

    International Nuclear Information System (INIS)

    Pring, D.J.; Henderson, R.G.; Keshavarzian, A.; Rivett, A.G.; Krausz, T.; Coombs, R.R.; Lavender, J.P.

    1986-01-01

    The value of indium-111-labeled granulocyte scanning to determine the presence of infection was assessed in 50 prosthetic joints (41 of which were painful) in 40 patients. Granulocytes were obtained from the patients' blood and labeled in plasma with indium 111 tropolonate. Abnormal accumulation of indium 111 in the region of the prosthesis was noted. Proven infection occurred in 11 prostheses, and all of the infections were detected by indium-111-labeled granulocyte scanning. Nineteen were not infected (including nine asymptomatic controls) and only two produced false-positive scans. This represents a specificity of 89.5%, sensitivity of 100%, and overall accuracy of 93.2%. These results compare favorably with plain radiography. There was no radiologic evidence of infection in three of the infected prostheses, and 10 of the noninfected prostheses had some radiologic features that suggested sepsis. We conclude that indium-granulocyte scanning can reliably detect or exclude infection in painful prosthetic joints and should prove useful in clinical management

  5. Payments by US pharmaceutical and medical device manufacturers to US medical journal editors: retrospective observational study.

    Science.gov (United States)

    Liu, Jessica J; Bell, Chaim M; Matelski, John J; Detsky, Allan S; Cram, Peter

    2017-10-26

    Objective  To estimate financial payments from industry to US journal editors. Design  Retrospective observational study. Setting  52 influential (high impact factor for their specialty) US medical journals from 26 specialties and US Open Payments database, 2014. Participants  713 editors at the associate level and above identified from each journal's online masthead. Main outcome measures  All general payments (eg, personal income) and research related payments from pharmaceutical and medical device manufacturers to eligible physicians in 2014. Percentages of editors receiving payments and the magnitude of such payments were compared across journals and by specialty. Journal websites were also reviewed to determine if conflict of interest policies for editors were readily accessible. Results  Of 713 eligible editors, 361 (50.6%) received some (>$0) general payments in 2014, and 139 (19.5%) received research payments. The median general payment was $11 (£8; €9) (interquartile range $0-2923) and the median research payment was $0 ($0-0). The mean general payment was $28 136 (SD $415 045), and the mean research payment was $37 963 (SD $175 239). The highest median general payments were received by journal editors from endocrinology ($7207, $0-85 816), cardiology ($2664, $0-12 912), gastroenterology ($696, $0-20 002), rheumatology ($515, $0-14 280), and urology ($480, $90-669). For high impact general medicine journals, median payments were $0 ($0-14). A review of the 52 journal websites revealed that editor conflict of interest policies were readily accessible (ie, within five minutes) for 17/52 (32.7%) of journals. Conclusions  Industry payments to journal editors are common and often large, particularly for certain subspecialties. Journals should consider the potential impact of such payments on public trust in published research. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  6. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty

    International Nuclear Information System (INIS)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M.; Trentani, F.; Trentani, P.; Tigani, D.; Nigrosoli, M.

    2000-01-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteriawere prosthesis loosening and severe (equal or superior to 7'' varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  7. Orthodontic space closure versus prosthetic replacement of missing upper lateral incisors in patients with bilateral cleft lip and palate.

    Science.gov (United States)

    Oosterkamp, Barbara C M; Dijkstra, Pieter U; Remmelink, Hendrik J; van Oort, Robert P; Sandham, Andrew

    2010-11-01

    To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate. The predominant mode of prosthetic replacement was resin-bonded bridges. The retrospective study group consisted of 17 patients treated with orthodontic space closure (13 men, four women; median age, 27.1 years; interquartile range, 20.6 to 33.3 years) and 10 patients treated with prosthetic replacement (five men, five women; median age, 27.7 years; interquartile range, 20.9 to 39.7 years). Dental aesthetics were evaluated by the patients and by a professional panel. Mandibular function was evaluated by means of the mandibular function impairment questionnaire. The level of mandibular impairment was calculated using the Function Impairment Rating Scale. With respect to dental aesthetics, no significant differences between patients treated with orthodontic space closure and prosthetic replacement were found. With respect to function, the level of mandibular impairment was significantly higher in patients treated with prosthetic replacement compared with patients treated with orthodontic space closure, as indicated by high scores on specific masticatory functions. Orthodontic space closure and prosthetic replacement in bilateral cleft lip and palate patients produce similar results in terms of aesthetics. In terms of function, prosthetic replacement results in significantly more impairment of specific masticatory functions.

  8. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    International Nuclear Information System (INIS)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul

    1987-01-01

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component

  9. Tactile Sensing Reflexes for Advanced Prosthetic Hands

    Science.gov (United States)

    2016-10-01

    Jeremy A. Fishel, Member, IEEE Figure 1. A) Custom NumaTac prosthetic fingertip sensor core and foam; B) Ottobock VariPlus Speed hand installed with two...oal – H ardw are P rototype D evelopm ent R   Identify alternatives for outcom e m easures R   E xplore sensor design param eters C Y16 G oals – C

  10. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

    Directory of Open Access Journals (Sweden)

    Ge Shuzhi

    2011-03-01

    Full Text Available Abstract Background Prosthetic arms and hands that can be controlled by the user's electromyography (EMG signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Methods Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a varying the internal topology of the finger phalanx and (b varying different materials for the internal and external layers. Results and Conclusions During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a little, (b ring, and (c middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to

  11. METHODOLOGY OF PROSTHETIC TREATMENT IN PATIENTS WITH MAXILLECTOMY

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2018-06-01

    Full Text Available Aim: The aim of the described method is to present the main stages in the prosthetic treatment with hollow bulb obturator, which provides optimum defect hermetization and restoration of the damaged functions. Materials and methods: The clinical case, described is on a 70-years-old patient with edentulous jaws and maxillary defect in the right half of the upper jaw. The preliminary impressions were taken with irreversible hydrocolloid impression material, and the final impressions were taken with additive silicone material. The occlusion height and the centric relations were registered as the classical technique. After the successful trial denture appointment, the surface of the plaster master model was covered by isolation polish. After this procedure, the master model was covered by even wax layer with 5mm thickness. It was designed to be thinner in the area of the resection line. The designed cavity was filled in with silicone impression material and covered with the folio. The base plate with the arranged teeth was fixed to the model, packed in the cuvette and finished from heat-cured acrylic resin with low quantity of residual monomer. After the polymerization process, the silicone material was removed, and the obturators cap was fixed to the denture’s base plate with cold cured acrylic resin. The obturator and the complete denture of the mandible were adjusted and articulated in patient’s mouth in the final clinical stage. Results: The applied prosthetic method allowed successful defect hermetization and helped for the restoration of the speech, feeding and patient’s self-esteem. Conclusion: Prosthetic rehabilitation of patients with maxillary resection is possible only with the application of specific treatment methods.

  12. Prosthetic joint infection due to Lysobacter thermophilus diagnosed by 16S rRNA gene sequencing

    Directory of Open Access Journals (Sweden)

    B Dhawan

    2016-01-01

    Full Text Available We report the first case of prosthetic joint infection caused by Lysobacter thermophilus which was identified by 16S rRNA gene sequencing. Removal of prosthesis followed by antibiotic treatment resulted in good clinical outcome. This case illustrates the use of molecular diagnostics to detect uncommon organisms in suspected prosthetic infections.

  13. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  14. Locking Editor A Utility For Protecting Software Exercises In The Computer Laboratory Of AMA University

    Directory of Open Access Journals (Sweden)

    Paul M. Grafilon

    2017-07-01

    Full Text Available The student of AMA University persistence in computing which has the keys to providing their talent needed to fill the computer laboratory in the computing professions. A range of factors can affect a students decision to remain in a computing major or change to another major if ever they feel that computing education is difficult. This has to describe the activities in computer laboratory specifically exercises machine problems and computing case studies interacting different application programs as the basis of their skills and knowledge in programming capability. The nature of those activities addresses by using of IDE as open source in all programming applications which may result of specific intervention such as using the editor to create a source file the code blocks comments and program statements are entered and the file saved. In case there are no corrective actions taken as the editor does not know this is supposed to be a source file as opposed to notes for class. If working in a position-dependent language like Java the developer would have to be very careful about indenting. The file has to be saved with the correct file extension and in a directory where the compiler can find it. Each source file has to be compiled separately if the program has a few source files they all have to be named separately in the compiler. When invoking the compiler it has to be directed to look in the correct directory for the source files and where the output files should be stored. If there is an error in the source file the compiler will output messages and fail to complete. For any errors the developer goes back and edits the source file working from line numbers and compiler messages to fix the problems and these steps continue until all the source files compile without errors. When linking each object file is specified as being part of the build. Again the locations for the object files and executable are given. There may be errors at this point

  15. Beacon Editor: Capturing Signal Transduction Pathways Using the Systems Biology Graphical Notation Activity Flow Language.

    Science.gov (United States)

    Elmarakeby, Haitham; Arefiyan, Mostafa; Myers, Elijah; Li, Song; Grene, Ruth; Heath, Lenwood S

    2017-12-01

    The Beacon Editor is a cross-platform desktop application for the creation and modification of signal transduction pathways using the Systems Biology Graphical Notation Activity Flow (SBGN-AF) language. Prompted by biologists' requests for enhancements, the Beacon Editor includes numerous powerful features for the benefit of creation and presentation.

  16. Significance of angular mismatch between vertebral endplate and prosthetic endplate in lumbar total disc replacement.

    Science.gov (United States)

    Lee, Chong Suh; Chung, Sung Soo; Oh, Sung Kyun; You, Je Wook

    2011-05-01

    A retrospective study. To determine whether angular mismatch between the vertebral endplate and prosthetic endplate during lumbar total disc replacement (L-TDR) affects the radiological and clinical outcomes. A prosthesis anchored to the vertebral body by using a large central keel carries an inherent risk of angular mismatch between the vertebral endplate and prosthetic endplate at a segment with a greater degree of lordosis, such as L5-S1. Theoretically, this angular mismatch can cause several problems, such as segmental hyperlordosis, anterior positioning of the upper prosthesis, posterior prosthetic edge subsidence, decreased range of motion (ROM), and a poor clinical outcome. This study evaluated 64 prosthetic levels of 56 patients who were implanted with L-TDR between June 2002 and February 2006. There were 38 and 26 prosthetic levels at the L4-5 and L5-S1, respectively. The mean follow-up period was 25.6 (12 to 49) months. The angle of mismatch between the lower endplate of the upper vertebral body and the upper prosthetic plate, segmental flexion/extension ROM, segmental lordosis angle at extension, distance from the posterior wall of the vertebral body to the posterior prosthetic edge were measured by obtaining radiographs. Clinically, the Visual Analogue Scale and Oswestry Disability Index were also evaluated. The angular mismatches between the upper vertebra and prosthesis at L4-5 and L5-S1 were 1.6 degree and 5.6 degree, respectively (P body to the posterior edge of the prosthesis in L5-S1 were 6.8 degree (4 to 13), 12.8 degree (8 to 17), and 3.8 mm (1 to 6 mm) in patients with an angular mismatch of 0.05). Angular mismatch was more common in L5-S1 than in L4-5. L-TDR at the most lordotic level, L5-S1, and implantation of an upper prosthesis with a mismatched angle seem to be the causes of a reduced segmental ROM, increased segmental lordosis, and anterior malpositioning of the prosthesis. However, these changes do not affect the clinical outcomes of

  17. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    Prosthetic joint failure is mainly caused by infection, aseptic failure (AF), and mechanical problems. Infection detection has been improved with modified culture methods and molecular diagnostics. However, comparisons between modified and conventional microbiology methods are difficult due...... to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...

  18. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  19. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    2011-01-01

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  20. Prosthetic model, but not stiffness or height, affects the metabolic cost of running for athletes with unilateral transtibial amputations.

    Science.gov (United States)

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-07-01

    Running-specific prostheses enable athletes with lower limb amputations to run by emulating the spring-like function of biological legs. Current prosthetic stiffness and height recommendations aim to mitigate kinematic asymmetries for athletes with unilateral transtibial amputations. However, it is unclear how different prosthetic configurations influence the biomechanics and metabolic cost of running. Consequently, we investigated how prosthetic model, stiffness, and height affect the biomechanics and metabolic cost of running. Ten athletes with unilateral transtibial amputations each performed 15 running trials at 2.5 or 3.0 m/s while we measured ground reaction forces and metabolic rates. Athletes ran using three different prosthetic models with five different stiffness category and height combinations per model. Use of an Ottobock 1E90 Sprinter prosthesis reduced metabolic cost by 4.3 and 3.4% compared with use of Freedom Innovations Catapult [fixed effect (β) = -0.177; P Run (β = -0.139; P = 0.002) prostheses, respectively. Neither prosthetic stiffness ( P ≥ 0.180) nor height ( P = 0.062) affected the metabolic cost of running. The metabolic cost of running was related to lower peak (β = 0.649; P = 0.001) and stance average (β = 0.772; P = 0.018) vertical ground reaction forces, prolonged ground contact times (β = -4.349; P = 0.012), and decreased leg stiffness (β = 0.071; P running. Instead, an optimal prosthetic model, which improves overall biomechanics, minimizes the metabolic cost of running for athletes with unilateral transtibial amputations. NEW & NOTEWORTHY The metabolic cost of running for athletes with unilateral transtibial amputations depends on prosthetic model and is associated with lower peak and stance average vertical ground reaction forces, longer contact times, and reduced leg stiffness. Metabolic cost is unrelated to prosthetic stiffness, height, and stride kinematic symmetry. Unlike nonamputees who decrease leg stiffness with

  1. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    Science.gov (United States)

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    Single-segment saphenous vein remains the optimal conduit for infrainguinal revascularization. In its absence, prosthetic conduit may be used. Existing data regarding the significance of anastomotic distal vein adjunct (DVA) usage with prosthetic grafts are based on small series. This is a retrospective cohort analysis derived from the regional Vascular Study Group of New England as well as the Brigham and Women's hospital database. A total of 1018 infrainguinal prosthetic bypass grafts were captured in the dataset from 73 surgeons at 15 participating institutions. Propensity scoring and 3:1 matching was performed to create similar exposure groups for analysis. Outcome measures of interest included: primary patency, freedom from major adverse limb events (MALEs), and amputation free survival at 1 year as a function of vein patch utilization. Time to event data were compared with the log-rank test; multivariable Cox proportional hazard models were used to evaluate the adjusted association between vein cuff usage and the primary end points. DVA was defined as a vein patch, cuff, or boot in any configuration. Of the 1018 bypass operations, 94 (9.2%) had a DVA whereas 924 (90.8%) did not (no DVA). After propensity score matching, 88 DVAs (25%) and 264 no DVAs (75%) were analyzed. On univariate analysis of the matched cohort, the DVA and no DVA groups were similar in terms of mean age (70.0 vs 69.0; P = .55), male sex (58.0% vs 58.3%; P > .99), and preoperative characteristics such as living at home (93.2% vs 94.3%; P = .79) and independent ambulatory status (72.7% vs 75.7%; P = .64). The DVA and no DVA groups had similar rates of major comorbidities such as hypertension chronic obstructive pulmonary disease, diabetes mellitus, coronary artery disease, and dialysis dependence (P > .05 for all). Likewise, they had similar rates of distal origin grafts (13.6% vs 12.5%; P = .85), critical limb ischemia indications (P = .53), and prior arterial bypass (58% vs 47%; P = .08

  2. Production of radioiodinated prosthetic group for indirect protein labeling

    International Nuclear Information System (INIS)

    Santos, Josefina da Silva

    2001-01-01

    Monoclonal antibodies and their fragments and, more recently, radiolabeled peptides have been extensively studied in order to develop radiopharmaceuticals for diagnostic and therapy in Nuclear Medicine. The radioiodination of proteins can be done by a direct method, with radioiodine being incorporated in to a tyrosine residue of the protein by electrophilic substitution. The main problem in the use of radioiodinated proteins, is that they are often dehalogenated in vivo by the action of specific enzymes, probably because of the structural similarity between iodophenyl groups and thyroid hormones. Several protein radioiodination methods have been developed in order to minimize this in vivo dehalogenation using prosthetic groups for indirect labeling. In this case, the radioiodine is first incorporated in to the prosthetic group that is subsequently attached to a terminal amino group or to a ε-amino group of lysine residue. The aim of this work is to obtain a radioiodinated prosthetic group for indirect labeling of proteins. The prosthetic group selected was the N-succinimidyl-4-radioiodine benzoate (SIB), obtained by the iodination of the p-bromobenzoic acid followed by the reaction with TSTU (0-(N-succinimidyl)-N,N,N',N'-tetramethyl uronium tetrafluoroborate) The results of these studies showed that the p-radio iodobenzoic acid was obtained with a radiochemical purity greater than 92% and a labeling yield of about 65%. Some reaction parameters were studied like temperature, time and Cu Cl mass (cataliser). The SIB was quantitatively obtained from p-radio iodobenzoic acid, using basic medium and after removing the water from the reaction using an nitrogen stream. The kinetic of this reaction is very fast with complete consumption of the p-radioiodebenzoic acid after 5 minutes. The coupling of the SIB prosthetic group to the protein was studied using Human Immunoglobulin (IgG) as a protein model. In a comparative way, the same protein was used on direct labeling

  3. EDITORIAL: Outgoing Editor-in-Chief Outgoing Editor-in-Chief

    Science.gov (United States)

    Hauptmann, Peter

    2012-01-01

    I started in 2002 as Editor-in-Chief of a well established journal—MST (Measurement Science and Technology). It was a time when modern means of communication offered new opportunities for the scientific community—for all scientists and engineers whether at universities, in industry or at other institutions—to access better quality information in a shorter time. This development helped us to be more efficient in our daily scientific work and to anticipate new trends faster than before. A flood of information was created by different search engines. A few online journals or journals published in emerging countries with a similar profile to MST appeared on the market. MST had to provide new answers in response to these developments. In 2002 I postulated two requirements to the journal. Firstly, the publisher has to be up to date. My impression over the years has been that IOPP is excellently organized. That has made it easier for the board members and all our reviewers to concentrate on the scientific aspects of our input to the journal. During all my visits to Bristol or my contacts with the IOPP staff I always met very professional and enthusiastic staff members. They have not only supported and encouraged the ideas and initiatives of the Editorial Board members, but they have also worked hard on establishing one of the most effective journal operations in the field of measurement science and technology. Many authors are well aware of this. Thus I am able to declare that the first requirement for a successful journal has been met. Secondly, the scientific level has to be high and the journal should attract readers from all over the world. This task was the responsibility of the Editorial Board members and of myself. Our strategy was on the one hand to ensure continuity in MST but on the other hand to be open to new trends and developments. Examples of these new aspects of the journal are fields like micro- and nanometrology, measurement techniques for

  4. A Generic Metadata Editor Supporting System Using Drupal CMS

    Science.gov (United States)

    Pan, J.; Banks, N. G.; Leggott, M.

    2011-12-01

    Metadata handling is a key factor in preserving and reusing scientific data. In recent years, standardized structural metadata has become widely used in Geoscience communities. However, there exist many different standards in Geosciences, such as the current version of the Federal Geographic Data Committee's Content Standard for Digital Geospatial Metadata (FGDC CSDGM), the Ecological Markup Language (EML), the Geography Markup Language (GML), and the emerging ISO 19115 and related standards. In addition, there are many different subsets within the Geoscience subdomain such as the Biological Profile of the FGDC (CSDGM), or for geopolitical regions, such as the European Profile or the North American Profile in the ISO standards. It is therefore desirable to have a software foundation to support metadata creation and editing for multiple standards and profiles, without re-inventing the wheels. We have developed a software module as a generic, flexible software system to do just that: to facilitate the support for multiple metadata standards and profiles. The software consists of a set of modules for the Drupal Content Management System (CMS), with minimal inter-dependencies to other Drupal modules. There are two steps in using the system's metadata functions. First, an administrator can use the system to design a user form, based on an XML schema and its instances. The form definition is named and stored in the Drupal database as a XML blob content. Second, users in an editor role can then use the persisted XML definition to render an actual metadata entry form, for creating or editing a metadata record. Behind the scenes, the form definition XML is transformed into a PHP array, which is then rendered via Drupal Form API. When the form is submitted the posted values are used to modify a metadata record. Drupal hooks can be used to perform custom processing on metadata record before and after submission. It is trivial to store the metadata record as an actual XML file

  5. Development and testing of new upper-limb prosthetic devices: research designs for usability testing.

    Science.gov (United States)

    Resnik, Linda

    2011-01-01

    The purposes of this article are to describe usability testing and introduce designs and methods of usability testing research as it relates to upper-limb prosthetics. This article defines usability, describes usability research, discusses research approaches to and designs for usability testing, and highlights a variety of methodological considerations, including sampling, sample size requirements, and usability metrics. Usability testing is compared with other types of study designs used in prosthetic research.

  6. QUALIDADE DE CONTEÚDO, O GRANDE DESAFIO PARA OS EDITORES CIENTÍFICOS/ CALIDAD DEL CONTENIDO, EL GRAN DESAFÍO PARA LOS EDITORES CIENTÍFICOS/ QUALITY OF CONTENT, THE GREAT CHALLENGE FOR SCIENTIFIC EDITORS

    Directory of Open Access Journals (Sweden)

    Tatiana Plata-Caviedes

    2012-07-01

    Full Text Available Discutem-se alguns problemas que atualmente afetam a qualidade do conteúdo das revistas científicas e ressalta-se o papel dos editores como responsáveis pela definição tanto da direção (o que se fará como da profundidade (até que ponto se avançará das pesquisas. Propõe-se que a relação ótima entre ambas se alcança a partir de um equilíbrio entre as três logias: terminologia, epistemologia e metodologia. Sob esta fundamentação, apresenta-se uma taxonomia para avaliação e análise de projetos de pesquisa, artigos e pareceres científicos. Conclui-se com propostas de ação específicas para todos os atores envolvidos na geração e difusão do conhecimento (autores, revisores, agências de fomento, instituições que publicam revistas e editores científicos, orientadas a melhorar a qualidade do conteúdo das publicações.

  7. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    OpenAIRE

    J. J. Gu; M. Meng; A. Cook; P. X. Liu

    2006-01-01

    Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the contro...

  8. From the Editors

    Directory of Open Access Journals (Sweden)

    Jason Harshman

    2016-11-01

    Full Text Available Teaching about globalizations and our interconnectedness with people and places around the world is an essential component of K-12 and higher education, but knowledge about global issues and news is not enough. Increased mobility, digital communication, and cultural hybridity, along with oppression and social injustice require that educators and students not only be able to communicate and collaborate with people different from them, but regularly engage in critical self-reflection around perceived norms and values. In January 2016, the editors of this special issue distributed a call for theoretical, research-based, and practitioner oriented manuscripts on teaching and learning that bring social studies and global citizenship education together. Evidence by the transnational contributions published within this issue of the Journal of Social Studies Education Research, the place of global citizenship education within the social studies is evolving, multifaceted, and not without complications. In short: just how it should be.

  9. Tensile strength and impact resistance properties of materials used in prosthetic check sockets, copolymer sockets, and definitive laminated sockets

    OpenAIRE

    Maria J. Gerschutz, PhD; Michael L. Haynes, MS; Derek M. Nixon, BS; James M. Colvin, MS

    2011-01-01

    Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn...

  10. Biomechanical characteristics, patient preference and activity level with different prosthetic feet: a randomized double blind trial with laboratory and community testing.

    Science.gov (United States)

    Raschke, Silvia U; Orendurff, Michael S; Mattie, Johanne L; Kenyon, David E A; Jones, O Yvette; Moe, David; Winder, Lorne; Wong, Angie S; Moreno-Hernández, Ana; Highsmith, M Jason; J Sanderson, David; Kobayashi, Toshiki

    2015-01-02

    Providing appropriate prosthetic feet to those with limb loss is a complex and subjective process influenced by professional judgment and payer guidelines. This study used a small load cell (Europa™) at the base of the socket to measure the sagittal moments during walking with three objective categories of prosthetic feet in eleven individuals with transtibial limb loss with MFCL K2, K3 and K4 functional levels. Forefoot stiffness and hysteresis characteristics defined the three foot categories: Stiff, Intermediate, and Compliant. Prosthetic feet were randomly assigned and blinded from participants and investigators. After laboratory testing, participants completed one week community wear tests followed by a modified prosthetics evaluation questionnaire to determine if a specific category of prosthetic feet was preferred. The Compliant category of prosthetic feet was preferred by the participants (P=0.025) over the Stiff and Intermediate prosthetic feet, and the Compliant and Intermediate feet had 15% lower maximum sagittal moments during walking in the laboratory (P=0.0011) compared to the Stiff feet. The activity level of the participants did not change significantly with any of the wear tests in the community, suggesting that each foot was evaluated over a similar number of steps, but did not inherently increase activity. This is the first randomized double blind study in which prosthetic users have expressed a preference for a specific biomechanical characteristic of prosthetic feet: those with lower peak sagittal moments were preferred, and specifically preferred on slopes, stairs, uneven terrain, and during turns and maneuvering during real world use. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement.

    Science.gov (United States)

    Mladenović, Dragan; Tosić, Goran; Zivković, Dusan; Djindjić, Natasa; Mladenović, Lidija; Mladenović, Sanja; Marković, Ivana

    2013-09-01

    In the management of edentulous spaces, there is a permanent need of a dentist-prosthetician in charge to consult other specialists. Modern telemedicine, based on powerful computer and telecomunication systems, offers an adequate answer to these challenges, being able to transfer and obtain clinical data and consultation information over large distances. Using smartphone or a computer, the teleconsultant acces the system, downloads and review the data and photographs and gave suggestions. The system then enables direct, real time contact with the consultant, chat, or directs them to contact each other by phone. We presented telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement in 3 cases with different teleconsultation requirements: the first case for prosthetic rehabilitation of his upper teeth, the second one for prosthetic management of his partial edentulousness and "a growth on his gums" in the vestibular region of the frontal teeth and the third one for prosthetic management of total edentulousness of her upper jaw. We used the system of telemedicine in dentistry, established at the Faculty of Medicine in Kosovska Mitrovica. The operation was based on the computer application system XPA3 Online, computer networking and mobile smartphone network. All consultations were succefull with no need for further procedures in regional center. The use of a mobile smartphone has brought about the mobility and availability of teleconsultant specialists in an extent never seen before. Prostheticians are thus able to offer better service to their patients and improve the quality of management of partially or totally edentulous patients, especially in rural areas.

  12. Surface EMG and intra-socket force measurement to control a prosthetic device

    Science.gov (United States)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  13. Rapid prototyping prosthetic hand acting by a low-cost shape-memory-alloy actuator.

    Science.gov (United States)

    Soriano-Heras, Enrique; Blaya-Haro, Fernando; Molino, Carlos; de Agustín Del Burgo, José María

    2018-06-01

    The purpose of this article is to develop a new concept of modular and operative prosthetic hand based on rapid prototyping and a novel shape-memory-alloy (SMA) actuator, thus minimizing the manufacturing costs. An underactuated mechanism was needed for the design of the prosthesis to use only one input source. Taking into account the state of the art, an underactuated mechanism prosthetic hand was chosen so as to implement the modifications required for including the external SMA actuator. A modular design of a new prosthesis was developed which incorporated a novel SMA actuator for the index finger movement. The primary objective of the prosthesis is achieved, obtaining a modular and functional low-cost prosthesis based on additive manufacturing executed by a novel SMA actuator. The external SMA actuator provides a modular system which allows implementing it in different systems. This paper combines rapid prototyping and a novel SMA actuator to develop a new concept of modular and operative low-cost prosthetic hand.

  14. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1987-10-15

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component.

  15. Illusory movement perception improves motor control for prosthetic hands

    Science.gov (United States)

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  16. Customized mold radiotherapy with prosthetic apparatus for oral cancers

    International Nuclear Information System (INIS)

    Noguchi, Tadahide; Tsuchiya, Yoshiyuki; Hayasaka, Junichi; Itoh, Hiroto; Jinbu, Yoshinori; Kusama, Mikio; Takahashi, Satoru; Nakazawa, Masanori

    2014-01-01

    Eight patients (6 males, 2 females; median age, 78 years; age range, 31-94 years) were treated by mold radiotherapy with a prosthetic apparatus for oral cancers between October 2006 and March 2013. The primary sites were the tongue in 3 cases, hard palate and buccal mucosa in 2 cases each, and oral floor in 1 case. The type of treatment consisted of radical radiotherapy and palliative radiotherapy in 2 cases each, and preoperative radiotherapy, postoperative radiotherapy, additional radiotherapy after external beam radiotherapy and systemic chemotherapy in 1 case each. Patients received 40-50 Gy in 8-10 fractions with mold radiotherapy. Two patients who received radical radiotherapy showed no signs of recurrence or metastasis. The present therapy contributed to patients' palliative, postoperative, and preoperative therapy. Mold radiotherapy with a prosthetic appliance was performed safely and was a useful treatment for several types of oral cancer. (author)

  17. Most Business Editors Find Journalism Graduates Still Unprepared

    Science.gov (United States)

    Pardue, Mary Jane

    2014-01-01

    In 2002, a study was published in "Newspaper Research Journal" that explored the preparedness of graduating journalism students to cover business news. In 2012, a follow-up survey of business editors at the nation's daily newspapers was done to see whether progress had been made in the training of journalism students for the…

  18. Publishing in Educational Psychology Journals: Comments from Editors

    Science.gov (United States)

    Nihalani, Priya K.; Mayrath, Michael C.

    2008-01-01

    The following paper emphasizes the importance of publishing and learning how to publish in educational psychology journals. We have compiled a set of recommendations based on advice from editors in the field and several other sources on how to publish. Additionally, this paper provides a step-by-step guide that graduate students and junior faculty…

  19. Adequacy of authors' replies to criticism raised in electronic letters to the editor

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Delamothe, Tony; Godlee, Fiona

    2010-01-01

    . Inclusion criteria Research papers generating substantive criticism in the rapid responses section on bmj.com. MAIN OUTCOME MEASURES: Severity of criticism (minor, moderate, or major) as judged by two editors and extent to which the criticism was addressed by authors (fully, partly, or not) as judged by two......OBJECTIVE: To investigate whether substantive criticism in electronic letters to the editor, defined as a problem that could invalidate the research or reduce its reliability, is adequately addressed by the authors. DESIGN: Cohort study. SETTING: BMJ between October 2005 and September 2007...... editors and the critics. RESULTS: A substantive criticism was raised against 105 of 350 (30%, 95% confidence interval 25% to 35%) included research papers, and of these the authors had responded to 47 (45%, 35% to 54%). The severity of the criticism was the same in those papers as in the 58 without author...

  20. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    Science.gov (United States)

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  1. Developing and modeling of voice control system for prosthetic robot arm in medical systems

    Directory of Open Access Journals (Sweden)

    Koksal Gundogdu

    2018-04-01

    Full Text Available In parallel with the development of technology, various control methods are also developed. Voice control system is one of these control methods. In this study, an effective modelling upon mathematical models used in the literature is performed, and a voice control system is developed in order to control prosthetic robot arms. The developed control system has been applied on four-jointed RRRR robot arm. Implementation tests were performed on the designed system. As a result of the tests; it has been observed that the technique utilized in our system achieves about 11% more efficient voice recognition than currently used techniques in the literature. With the improved mathematical modelling, it has been shown that voice commands could be effectively used for controlling the prosthetic robot arm. Keywords: Voice recognition model, Voice control, Prosthetic robot arm, Robotic control, Forward kinematic

  2. Red's natural editor, a program designed to edit FORTRAN programs

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1993-01-01

    An EDITOR code is documented which supplements the 1994 ENDF Pre-processing Code Package which is available from the IAEA Nuclear Data Section for the processing of ENDF formatted nuclear data libraries. (author)

  3. Dynamic Facial Prosthetics for Sufferers of Facial Paralysis

    Directory of Open Access Journals (Sweden)

    Fergal Coulter

    2011-10-01

    Full Text Available BackgroundThis paper discusses the various methods and the materialsfor the fabrication of active artificial facial muscles. Theprimary use for these will be the reanimation of paralysedor atrophied muscles in sufferers of non-recoverableunilateral facial paralysis.MethodThe prosthetic solution described in this paper is based onsensing muscle motion of the contralateral healthy musclesand replicating that motion across a patient’s paralysed sideof the face, via solid state and thin film actuators. Thedevelopment of this facial prosthetic device focused onrecreating a varying intensity smile, with emphasis ontiming, displacement and the appearance of the wrinklesand folds that commonly appear around the nose and eyesduring the expression.An animatronic face was constructed with actuations beingmade to a silicone representation musculature, usingmultiple shape-memory alloy cascades. Alongside theartificial muscle physical prototype, a facial expressionrecognition software system was constructed. This formsthe basis of an automated calibration and reconfigurationsystem for the artificial muscles following implantation, soas to suit the implantee’s unique physiognomy.ResultsAn animatronic model face with silicone musculature wasdesigned and built to evaluate the performance of ShapeMemory Alloy artificial muscles, their power controlcircuitry and software control systems. A dual facial motionsensing system was designed to allow real time control overmodel – a piezoresistive flex sensor to measure physicalmotion, and a computer vision system to evaluate real toartificial muscle performance.Analysis of various facial expressions in real subjects wasmade, which give useful data upon which to base thesystems parameter limits.ConclusionThe system performed well, and the various strengths andshortcomings of the materials and methods are reviewedand considered for the next research phase, when newpolymer based artificial muscles are constructed

  4. EDITORIAL: Message from the Editor

    Science.gov (United States)

    Thomas, Paul

    2009-01-01

    Plasmaphysik, Germany) V. Philipps (Forschungszentrum Juelich, Germany) S. Zweben (Princeton Plasma Physics Laboratory, USA) Y. Hirano (National Institute of Advanced Industrial Science and Technology, Japan) Y. Takase (Tokyo University, Japan) In addition there is a group of several hundred referees who have helped us in the past year to maintain the high scientific standard of Nuclear Fusion. At the end of this issue we give the full list of all referees for 2008. Our thanks to them! Authors The winner of the 2007 award was Clemente Angioni for the paper entitled `Density response to central electron heating: theoretical investigations and experimental observations in ASDEX Upgrade' (Nucl. Fusion 44 8277-845). The winner of the 2008 Nuclear Fusion award is Todd Evans et al for the paper `Suppression of large edge localized modes with edge resonant magnetic fields in high confinement DIII-D plasmas' (Nucl. Fusion 45 595-607). The awards were presented by the IAEA Deputy Director General, Werner Burkart, and the Chairman of the Board of Editors, Mitsuru Kikuchi, on 16 October 2008 at the 22nd IAEA Fusion Energy Conference in Geneva, Switzerland. Given the topicality of these papers for the ITER design, it is a matter of pride to the journal that the work should be published in Nuclear Fusion. Reviews Like many who have worked for a long time in the field, I still make use of Nuclear Fusion Reviews that go back 20 or 30 years. It is particularly useful, therefore, that the Board of Editors has been working to re-activate the review programme. The first fruits will appear in this issue, in the form of `A review of zonal flow experiments', by Akihide Fujisawa. The special procedures for Reviews should be noted: most specifically that they should normally be commissioned by the Board of Editors. However, not only is the Board of Editors working on a programme but I am sure that they would be pleased to consider suggestions for review subjects. Letters The reputation of Nuclear

  5. Ureaplasma parvum prosthetic joint infection detected by PCR.

    Science.gov (United States)

    Farrell, John J; Larson, Joshua A; Akeson, Jeffrey W; Lowery, Kristin S; Rounds, Megan A; Sampath, Rangarajan; Bonomo, Robert A; Patel, Robin

    2014-06-01

    We describe the first reported case of Ureaplasma parvum prosthetic joint infection (PJI) detected by PCR. Ureaplasma species do not possess a cell wall and are usually associated with colonization and infection of mucosal surfaces (not prosthetic material). U. parvum is a relatively new species name for certain serovars of Ureaplasma urealyticum, and PCR is useful for species determination. Our patient presented with late infection of his right total knee arthroplasty. Intraoperative fluid and tissue cultures and pre- and postoperative synovial fluid cultures were all negative. To discern the pathogen, we employed PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS). Our patient's failure to respond to empirical antimicrobial treatment and our previous experience with PCR/ESI-MS in culture-negative cases of infection prompted us to use this approach over other diagnostic modalities. PCR/ESI-MS detected U. parvum in all samples. U. parvum-specific PCR testing was performed on all synovial fluid samples to confirm the U. parvum detection. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  6. A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members with Leg Amputations

    Science.gov (United States)

    2017-09-01

    mobility, prosthetic foot preference and walking ability after two weeks of use in the home and community setting. No exclusions based on sex , race...2012 Page 17 of 33 Data collection Photos and video recording With the participant’s explicit consent, we may take video and photos during portions of...this study, for documentation and use in research publications. All videos and photos will exclue the participant’s face and identifying marks will

  7. Three-dimensional flow structures past a bio-prosthetic valve in an in-vitro model of the aortic root

    OpenAIRE

    Hasler, David; Obrist, Dominik

    2018-01-01

    The flow field past a prosthetic aortic valve comprises many details that indicate whether the prosthesis is functioning well or not. It is, however, not yet fully understood how an optimal flow scenario would look, i.e. which subtleties of the fluid dynamics in place are essential regarding the durability and compatibility of a prosthetic valve. In this study, we measured and analyzed the 3D flow field in the vicinity of a bio-prosthetic heart valve in function of the aortic root size. The m...

  8. Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty.

    Science.gov (United States)

    Weber, Markus; Woerner, Michael; Craiovan, Benjamin; Voellner, Florian; Worlicek, Michael; Springorum, Hans-Robert; Grifka, Joachim; Renkawitz, Tobias

    2016-12-01

    In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.

  9. Oral health-related quality of life and prosthetic status of nursing home residents with or without dementia.

    Science.gov (United States)

    Klotz, Anna-Luisa; Hassel, Alexander Jochen; Schröder, Johannes; Rammelsberg, Peter; Zenthöfer, Andreas

    2017-01-01

    The objective of this cross-sectional study was to evaluate the effect of prosthetic status on the oral health-related quality of life (OHRQoL) of nursing home residents with or without dementia. The study was performed in 14 nursing homes across the federal state of Baden-Württemberg, Germany. All eligible participants were included, and general and medical information and information about their dental and prosthetic statuses were collected. The Geriatric Oral Health Assessment Index (GOHAI) was administered to evaluate OHRQoL. The Mini-Mental State Examination (MMSE) served to classify participants into living or not living with dementia according to the established cutoff value for dementia (MMSE health was also similar in both groups ( P >0.05). The number of teeth (odds ratio [OR]: 2.0), the type of prosthetic status (OR: 6.5), and denture-related treatment needs (OR: 2.4) were the major factors significantly affecting OHRQoL ( P nursing home residents is substantially compromised. Several prosthetic treatment needs for residents living with or without dementia were identified. Edentulism without tooth replacement and having <5 teeth resulted in an increased risk of substantially compromised OHRQoL. Further studies should be conducted to determine whether improvements in prosthetic status can increase OHRQoL.

  10. Guest editors' introduction to the special section on information technology and evidence implementation.

    Science.gov (United States)

    Abernethy, Amy P; Hesse, Bradford W

    2011-03-01

    Healthcare is experiencing a transformation-perhaps as significant as the publication of the first randomized controlled trial-in the ways in which basic discovery is translated into effective practice. The change is being precipitated by efforts to undergird the healthcare industry with the same transformational capacities from information technology as is afforded to other sectors in the economy. Although the transformation has been slow in materializing, change is expected to accelerate under the stimulating influence of the Health Information Technology for Economic and Clinical Health Act of 2009 and the Patient Protection and Affordable Care Act of 2010. As the changes ripple throughout the healthcare sector, two aspects of medical care in the twenty-first century are expected to rise in importance: data and behavior. Each of the articles within this inaugural issue of Translational Behavioral Medicine has been selected to illustrate treatment of these two assets in one way or another. The editors hope this first issue will serve as a vanguard illustration for how behavioral scientists can be included as integral members of the design team in creating a new platform for evidence implementation in the USA and abroad.

  11. A Virtual Environments Editor for Driving Scenes

    Directory of Open Access Journals (Sweden)

    Ronald R. Mourant

    2003-12-01

    Full Text Available The goal of this project was to enable the rapid creation of three-dimensional virtual driving environments. We designed and implemented a high-level scene editor that allows a user to construct a driving environment by pasting icons that represent 1 road segments, 2 road signs, 3 trees and 4 buildings. These icons represent two- and three-dimensional objects that have been predesigned. Icons can be placed in the scene at specific locations (x, y, and z coordinates. The editor includes the capability of a user to "drive" a vehicle using a computer mouse for steering, accelerating and braking. At any time during the process of building a virtual environment, a user may switch to "Run Mode" and inspect the three-dimensional scene by "driving" through it using the mouse. Adjustments and additions can be made to the virtual environment by going back to "Build Mode". Once a user is satisfied with the threedimensional virtual environment, it can be saved in a file. The file can used with Java3D software that enables the traversing of three-dimensional environments. The process of building virtual environments from predesigned icons can be applied to many other application areas. It will enable novice computer users to rapidly construct and use three-dimensional virtual environments.

  12. Editor's Comment and Announcement.

    Science.gov (United States)

    Bortolussi, Robert

    2017-12-17

    It is hard to believe but Clinical and Investigative Medicine (CIM), the official journal of Canadian Society for Clinical Investigation (CSCI), will soon celebrate its 40th birthday!  Over these past four decades, CIM has been the premier journal for Canadian clinician scientists; publishing over 1,000 articles on breakthroughs and major advances from Canada and around the world.  We are listed on Medline, PubMed and the Library of Science. We have been, and will continue to be, an independent journal. To celebrate this auspicious occasion, we have plans to become an even bigger showpiece for national and international clinical advances. We want to connect more closely with Canadian clinician scientists and trainees and we particularly want to encourage more Canadian publications. Changes will soon be coming to CIM with several new features: Newsletter with announcements and news on activities of interest to clinician scientists and trainees; Focused Reviews on specific areas of research; Reflections on work and life experiences of trainees and senior clinician scientists; Methods Papers describing novel methods anticipated to be useful for others; and  Guidelines or Recommendations on clinical care that are endorsed by a Canadian Medical or Surgical Society. Starting in 2018, we will be publishing on a quarterly basis. This will help to ensure we will focus on important breakthroughs and commentaries. However, we are also planning a special edition in the autumn to commemorate the 40th birthday. Stay tuned! Of course CIM will continue to publish original papers on discoveries in pathophysiology, prevention, management, treatment and outcome of clinical problems confronting clinicians in Canada and around the world.  Please join us as we embark on these changes and a new era for CIM, Robert Bortolussi Clinical and Investigative Medicine (CIM) Editor in Chief.

  13. Adolescent Sexual Initiation through the Lens of Letters to the Editor Published in Polish Teenage Magazines

    Science.gov (United States)

    Kopacz, Marek S.; Bajka-Kopacz, Aleksandra

    2012-01-01

    Almost all teenage magazines invite readers to submit questions concerning relationships, published as letters to the editor, popularly called "advice columns," often containing explicit questions about sexuality. This study aims to examine, firstly, how themes related to sexual initiation are presented in letters to the editor published…

  14. EDITORIAL: Incoming Editor-in-Chief

    Science.gov (United States)

    Webb, Steve

    2006-01-01

    Physics in Medicine and Biology (PMB) is a journal that originated in the UK but is now rightly regarded as one of the pre-eminent international journals for the publication of material coming within its remit. It is 50 years old and its maturity is an outcome of the consistent support of high performing authors, a supportive and professional publishing house, dedicated referees, many vigorous and conscientious editorial boards and the collective input of the 10 previous Editors as listed in his incoming editorial (January 2000 issue) by the retiring Editor, Professor Alun Beddoe. The scientific climate and it associated publication modus operandi in the 1950s was very different from that at the current time and the journal has evolved to reflect this. Hence today the scope of content is somewhat broader, the size of the journal is vastly greater, the whole publication process is slicker and more efficient and a paper in PMB is highly prized by its authors and those who look to quality factors and impact. The quality of the journal still relies on the voluntary labour and expertise of its busy international referees and Board members. For many years I have tried to place my own research material in PMB and encourage my teams to do likewise, not only acknowledging the prestige of the journal but also because of the extraordinarily fast turnaround time of all the processes without any loss of quality. This serves us very well and the publishing team are to be congratulated. Some things seem to change more slowly or not at all, however. The prediction, when I started my research career, that books and journals would be dinosaurs by now has manifestly not come true and, whilst most of us are addicted (and why not?) to the electronic ways of doing things that can be done by more traditional ways, PMB and a packet of reprints from time to time arriving by post still has a reassuring feel despite the fact that the papers have been `on-line' for a while before. An incoming

  15. An editor's memoir: reflections and premonitions.

    Science.gov (United States)

    Kovacs, Arthur L

    2013-12-01

    The author served as the second Editor of this journal. In the article that follows, he reminisces about the state of the publication when he assumed responsibility for it and comments on the nature of the profession during the time of his incumbency. He reflects on the creative innovation and ferment in both the theories and tactics of psychotherapy unfolding during the 1970s and closes with statements of concern about developments within the field that are ominous and have come to the fore over the decades since he left office in 1983.

  16. Swing Phase Control of Semi-Active Prosthetic Knee Using Neural Network Predictive Control With Particle Swarm Optimization.

    Science.gov (United States)

    Ekkachai, Kittipong; Nilkhamhang, Itthisek

    2016-11-01

    In recent years, intelligent prosthetic knees have been developed that enable amputees to walk as normally as possible when compared to healthy subjects. Although semi-active prosthetic knees utilizing magnetorheological (MR) dampers offer several advantages, they lack the ability to generate active force that is required during some states of a normal gait cycle. This prevents semi-active knees from achieving the same level of performance as active devices. In this work, a new control algorithm for a semi-active prosthetic knee during the swing phase is proposed to reduce this gap. The controller uses neural network predictive control and particle swarm optimization to calculate suitable command signals. Simulation results using a double pendulum model show that the generated knee trajectory of the proposed controller is more similar to the normal gait than previous open-loop controllers at various ambulation speeds. Moreover, the investigation shows that the algorithm can be calculated in real time by an embedded system, allowing for easy implementation on real prosthetic knees.

  17. Corynebacterium minutissimum vascular graft infection: case report and review of 281 cases of prosthetic device-related Corynebacterium infection.

    Science.gov (United States)

    Reece, Rebecca M; Cunha, Cheston B; Rich, Josiah D

    2014-09-01

    Corynebacterium spp. have proven their pathogenic potential in causing infections, particularly in the setting of immunosuppression and prosthetic devices. We conducted a PubMed literature review of all cases of Corynebacterium prosthetic device infections published in the English language through December 2013. The majority of cases involved peritoneal dialysis and central venous catheters, but prosthetic joints and central nervous system shunts/drains were also involved. The management of these cases in terms of retention or removal of the device was not uniform; however, the overall mortality remained the same among both groups. All of these prosthetic device infections pose potential problems in management when the device cannot be removed safely for the patient, especially with the lack of data on the pathogenicity of Corynebacterium species. However with better identification of species and sensitivities, successful treatment is possible even with retention of the device.

  18. Role of CT in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Suchá, D.

    2016-01-01

    Valvular heart disease accounts for a substantial part of the cardiovascular disease worldwide with an estimated prevalence of 2.5% in the Western population aged <65 years and over 13% in the population aged >75 years. Surgical prosthetic heart valve (PHV) replacement is the indicated therapy for

  19. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    NARCIS (Netherlands)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if

  20. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    Science.gov (United States)

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  1. Locomotor Performance During Rehabilitation of People With Lower Limb Amputation and Prosthetic Nonuse 12 Months After Discharge.

    Science.gov (United States)

    Roffman, Caroline E; Buchanan, John; Allison, Garry T

    2016-07-01

    It is recognized that multifactorial assessments are needed to evaluate balance and locomotor function in people with lower limb amputation. There is no consensus on whether a single screening tool could be used to identify future issues with locomotion or prosthetic use. The purpose of this study was to determine whether different tests of locomotor performance during rehabilitation were associated with significantly greater risk of prosthetic abandonment at 12 months postdischarge. This was a retrospective cohort study. Data for descriptive variables and locomotor tests (ie, 10-Meter Walk Test [10MWT], Timed "Up & Go" Test [TUGT], Six-Minute Walk Test [6MWT], and Four Square Step Test [FSST]) were abstracted from the medical records of 201 consecutive participants with lower limb amputation. Participants were interviewed and classified as prosthetic users or nonusers at 12 months postdischarge. The Mann-Whitney U test was used to analyze whether there were differences in locomotor performance. Receiver operating characteristic curves were generated to determine performance thresholds, and relative risk (RR) was calculated for nonuse. At 12 months postdischarge, 18% (n=36) of the participants had become prosthetic nonusers. Performance thresholds, area under the curve (AUC), and RR of nonuse (95% confidence intervals [CI]) were: for the 10MWT, if walking speed was ≤0.44 ms(-1) (AUC=0.743), RR of nonuse=2.76 (95% CI=1.83, 3.79; PLocomotor performance during rehabilitation may predict future risk of prosthetic nonuse. It may be implied that the 10MWT has the greatest clinical utility as a single screening tool for prosthetic nonuse, given the highest proportion of participants were able to perform this test early in rehabilitation. However, as locomotor skills improve, other tests (in particular, the 6MWT) have specific clinical utility. To fully enable implementation of these locomotor criteria for prosthetic nonuse into clinical practice, validation is warranted

  2. Developing Media Module Proposed to Editor in Editorial Division

    Science.gov (United States)

    Kristanto, A.; Mustaji; Mariono, A.; Sulistiowati; Nuryati, D. W.

    2018-01-01

    In this era of technology in Indonesia, various publishers introduce themselves and participate in advancing the quality of education through the publication of various books as the learning sources. One of the publishers is PT. JP Press. In compiling the learning sources, we found some problems that are left unresolved by the editor. The purpose of this research is to overcome the problems that exist in PT. JP Press by developing media module. This development research uses the ADDIE model. The types of data used in this study are qualitative and quantitative data obtained based on the results of structured interviews with material experts and media experts, as well as the editorial response questionnaire provided for individual try-out and small group try-out. Therefore, it can be concluded that the medium of elementary school supplementary module proposed to the editors of PT. JP Press is valuable to be used in the teaching and learning activities.

  3. Using computed tomography and 3D printing to construct custom prosthetics attachments and devices.

    Science.gov (United States)

    Liacouras, Peter C; Sahajwalla, Divya; Beachler, Mark D; Sleeman, Todd; Ho, Vincent B; Lichtenberger, John P

    2017-01-01

    The prosthetic devices the military uses to restore function and mobility to our wounded warriors are highly advanced, and in many instances not publically available. There is considerable research aimed at this population of young patients who are extremely active and desire to take part in numerous complex activities. While prosthetists design and manufacture numerous devices with standard materials and limb assemblies, patients often require individualized prosthetic design and/or modifications to enable them to participate fully in complex activities. Prosthetists and engineers perform research and implement digitally designs in collaboration to generate equipment for their patient's rehabilitation needs. 3D printing allows for these devices to be manufactured from an array of materials ranging from plastic to titanium alloy. Many designs require form fitting to a prosthetic socket or a complex surface geometry. Specialty items can be scanned using computed tomography and digitally reconstructed to produce a virtual 3D model the engineer can use to design the necessary features of the desired prosthetic, device, or attachment. Completed devices are tested for fit and function. Numerous custom prostheses and attachments have been successfully translated from the research domain to clinical reality, in particular, those that feature the use of computed tomography (CT) reconstructions. The purpose of this project is to describe the research pathways to implementation for the following clinical designs: sets of bilateral hockey skates; custom weightlifting prosthetic hands; and a wine glass holder. This article will demonstrate how to incorporate CT imaging and 3D printing in the design and manufacturing process of custom attachments and assistive technology devices. Even though some of these prosthesis attachments may be relatively simple in design to an engineer, they have an enormous impact on the lives of our wounded warriors.

  4. Telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement

    Directory of Open Access Journals (Sweden)

    Mladenović Dragan

    2013-01-01

    Full Text Available Introduction. In the management of edentulous spaces, there is a permanent need of a dentist-prosthetician in charge to consult other specialists. Modern telemedicine, based on powerful computer and telecomunication systems, offers an adequate answer to these challenges, being able to transfer and obtain clinical data and consultation information over large distances. Using smartphone or a computer, the teleconsultant acces the system, downloads and review the data and photographs and gave suggestions. The system then enables direct, real time contact with the consultant, chat, or directs them to contact each other by phone. Case report. We presented telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement in 3 cases with different teleconsultation requirements: the first case for prosthetic rehabilitation of his upper teeth, the second one for prosthetic management of his partial edentulousness and “a growth on his gums” in the vestibular region of the frontal teeth and the third one for prosthetic management of total edentulousness of her upper jaw. We used the system of telemedicine in dentistry, established at the Faculty of Medicine in Kosovska Mitrovica. The operation was based on the computer application system XPA3 Online, computer networking and mobile smartphone network. All consultations were succefull with no need for further procedures in regional center. Conclusion. The use of a mobile smartphone has brought about the mobility and availability of teleconsultant specialists in an extent never seen before. Prostheticians are thus able to offer better service to their patients and improve the quality of management of partially or totally edentulous patients, especially in rural areas.

  5. Automated hexahedral mesh generation from biomedical image data: applications in limb prosthetics.

    Science.gov (United States)

    Zachariah, S G; Sanders, J E; Turkiyyah, G M

    1996-06-01

    A general method to generate hexahedral meshes for finite element analysis of residual limbs and similar biomedical geometries is presented. The method utilizes skeleton-based subdivision of cross-sectional domains to produce simple subdomains in which structured meshes are easily generated. Application to a below-knee residual limb and external prosthetic socket is described. The residual limb was modeled as consisting of bones, soft tissue, and skin. The prosthetic socket model comprised a socket wall with an inner liner. The geometries of these structures were defined using axial cross-sectional contour data from X-ray computed tomography, optical scanning, and mechanical surface digitization. A tubular surface representation, using B-splines to define the directrix and generator, is shown to be convenient for definition of the structure geometries. Conversion of cross-sectional data to the compact tubular surface representation is direct, and the analytical representation simplifies geometric querying and numerical optimization within the mesh generation algorithms. The element meshes remain geometrically accurate since boundary nodes are constrained to lie on the tubular surfaces. Several element meshes of increasing mesh density were generated for two residual limbs and prosthetic sockets. Convergence testing demonstrated that approximately 19 elements are required along a circumference of the residual limb surface for a simple linear elastic model. A model with the fibula absent compared with the same geometry with the fibula present showed differences suggesting higher distal stresses in the absence of the fibula. Automated hexahedral mesh generation algorithms for sliced data represent an advancement in prosthetic stress analysis since they allow rapid modeling of any given residual limb and optimization of mesh parameters.

  6. Histopathological and Immunohistochemical Evaluation of Pannus Tissue in Patients with Prosthetic Valve Dysfunction.

    Science.gov (United States)

    Karakoyun, Süleyman; Ozan Gürsoy, Mustafa; Yesin, Mahmut; Kalçık, Macit; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Emrah Oğuz, Ali; Çoban Kökten, Şermin; Nimet Karadayı, Ayşe; Tuncer, Altuğ; Köksal, Cengiz; Gökdeniz, Tayyar; Özkan, Mehmet

    2016-01-01

    Prosthetic valve dysfunction due to pannus formation is a rare but serious complication. Currently, limited data are available concerning the pathogenesis and immunohistochemical properties of pannus. The study aim was to investigate the morphological, histopathological and immunohistochemical characteristics of pannus formation in patients with prosthetic valve dysfunction. A total of 35 patients (10 males, 25 females; mean age 44 ± 16 years) who had undergone re-do valve surgery due to prosthetic valve obstruction was enrolled in the study. Immunohistochemical studies were aimed at evaluating the expression of alphasmooth muscle actin (α-SMA) and desmin in myofibroblasts and smooth muscle cells; epithelial membrane antigen (EMA) in epithelial cells; and CD34, Factor VIII and vascular endothelial growth factor (VEGF) in endothelial cells. Matrix metalloproteinases (MMPs) -2 and -9, and transforming growth factor-beta (TGF-β) were used to demonstrate cytokine release from macrophages, leukocytes, fibroblasts and myofibroblasts. Pannus appeared as a tough and thick tissue hyperplasia which began from outside the suture ring in the periannular region and extended to the inflow and outflow surfaces of the prosthetic valves. Histopathological analysis showed the pannus tissue to consist of chronic inflammatory cells (lymphocytes, plasma cells, macrophages and foreign body giant cells), spindle cells such as myofibroblasts, capillary blood vessels and endothelial cells laying down the lumens. Calcification was present in the pannus tissue of 19 explanted prostheses. Immunohistochemical studies revealed positive α-SMA expression in all patients, whereas 60.5% of patients were positive for desmin, 50% for EMA, 42.1% for VEGF, 39.5% for TBF-β, 42.1% for MMP-2, 86.8% for CD34, and 97.4% for Factor VIII. MMP-9 was negative in all patients. Pannus tissue appears to be formed as the result of a neointimal response in periannular regions of prosthetic valves that consist

  7. EFFICIENCY OF PROSTHETIC TREATMENT WITH POST RESECTION PROSTHESES WITH SOLID SUBSTITUTE PART

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2016-08-01

    Full Text Available Aim: The aim of this study is to track the effectiveness of prosthetic treatment with post resection dentures with solid substitute part and their role in the restoration of damaged functions. Materials and methods: The study included 14 patients (9 men and 5 women with different size and location of defects in the upper jaw treated in the period 2010-2016 with post resection prostheses with a solid substitute part. The impressions were taken with irreversible hydrocolloid impression material. The prostheses were completed by heat-curing acrylic with low quantity residual monomer. The effectiveness of prosthetics was evaluated by the method of Mihaylov for both oral-nasal examination of the pressure with the device "Oronasopneumotest." For objectifying and assess the occlusal-articulation ratios was held computerized occlusal analysis with the system T-SCAN 8. Results: The results showed successful obturation and sealing of defects in all patients. It was found satisfactory recovery of the speaking function and normalization of occlusal-articulation ratios. Conclusion: The prosthetic treatment with post resection prostheses with a solid substitute part allows successful recovery of the lost speech and chewing functions, helping to restore self esteem and social rehabilitation of patients.

  8. Computed Tomography of the complications of prosthetic surgery of the abdominal aorta

    International Nuclear Information System (INIS)

    Giovagnorio, Francesco; Andreoli, Chiara; De Cicco, Maria Luisa

    1997-01-01

    Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7± 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT confirmed its important role in the study of the complications of prosthetic aortic surgery, despite its know poor specificity in the demonstration of the aorta in the first 2-3 months postoperatively, in the initial stages of infection and in the diagnosis of aorta-enteric fistulas

  9. Prosthetic graft infection: limitations of indium white blood cell scanning

    International Nuclear Information System (INIS)

    Brunner, M.C.; Mitchell, R.S.; Baldwin, J.C.; James, D.R.; Olcott, C. IV; Mehigan, J.T.; McDougall, I.R.; Miller, D.C.

    1986-01-01

    The lack of a rapid, noninvasive, and accurate method to confirm or rule out prosthetic graft infection continues to constitute a compelling and vexing clinical problem. A host of adjunctive diagnostic techniques has been used in the past, but early promising results subsequently have usually not yielded acceptable sensitivity (reflecting false negatives) and specificity (reflecting false positive) data. White blood cell (WBC) indium 111 scanning has recently been added to this list. The utility and accuracy of 111 In WBC scans were assessed by retrospective review of WBC scan results in 70 patients undergoing evaluation for possible prosthetic graft infection over a 7-year period. Operative and autopsy data (mean follow-up, 18 months for survivors with negative scans) were used to confirm the 22 positive, 45 negative, and three equivocal WBC scans. The false positive rate (+/- 70% confidence limits) was 36% +/- 6% (n = 8) among the 22 patients with positive scans (44% +/- 6% [11 of 25] if the three equivocal scans are included as false positive), yielding a specificity of 85% +/- 5% and an overall accuracy rate of 88% +/- 4% (80% +/- 5% and 84% +/- 5%, respectively, if the three equivocal cases are considered as false positive). All three patients with equivocal scans ultimately were judged not to have prosthetic graft infection. As implied by the high accuracy rate, the sensitivity of the test was absolute (100% [14 of 14]); there were no false negative results

  10. Comparison of using different bridge prosthetic designs for partial defect restoration through mathematical modeling.

    Science.gov (United States)

    Styranivska, Oksana; Kliuchkovska, Nataliia; Mykyyevych, Nataliya

    2017-01-01

    To analyze the stress-strain states of bone and abutment teeth during the use of different prosthetic designs of fixed partial dentures with the use of relevant mathematical modeling principles. The use of Comsol Multiphysics 3.5 (Comsol AB, Sweden) software during the mathematical modeling of stress-strain states provided numerical data for analytical interpretation in three different clinical scenarios with fixed dentures and different abutment teeth and demountable prosthetic denture with the saddle-shaped intermediate part. Microsoft Excel Software (Microsoft Office 2017) helped to evaluate absolute mistakes of stress and strain parameters of each abutment tooth during three modeled scenarios and normal condition and to summarize data into the forms of tables. In comparison with the fixed prosthetic denture supported by the canine, first premolar, and third molar, stresses at the same abutment teeth with the use of demountable denture with the saddle-shaped intermediate part decreased: at the mesial abutment tooth by 2.8 times, at distal crown by 6.1 times, and at the intermediate part by 11.1 times, respectively, the deformation level decreased by 3.1, 1.9, and 1.4 times at each area. The methods of mathematical modeling proved that complications during the use of fixed partial dentures based on the overload effect of the abutment teeth and caused by the deformation process inside the intermediate section of prosthetic construction.

  11. Determining asymmetry of roll-over shapes in prosthetic walking

    NARCIS (Netherlands)

    Curtze, C.; Otten, Bert; Hof, A.L.; Postema, K.

    2011-01-01

    How does the inherent asymmetry of the locomotor system in people with lower-limb amputation affect the ankle-foot roll-over shape of prosthetic walking? In a single-case design, we evaluated the walking patterns of six people with lower-limb amputation (3 transtibial and 3 transfemoral) and three

  12. Fiber-array based optogenetic prosthetic system for stimulation therapy

    Science.gov (United States)

    Gu, Ling; Cote, Chris; Tejeda, Hector; Mohanty, Samarendra

    2012-02-01

    Recent advent of optogenetics has enabled activation of genetically-targeted neuronal cells using low intensity blue light with high temporal precision. Since blue light is attenuated rapidly due to scattering and absorption in neural tissue, optogenetic treatment of neurological disorders may require stimulation of specific cell types in multiple regions of the brain. Further, restoration of certain neural functions (vision, and auditory etc) requires accurate spatio-temporal stimulation patterns rather than just precise temporal stimulation. In order to activate multiple regions of the central nervous system in 3D, here, we report development of an optogenetic prosthetic comprising of array of fibers coupled to independently-controllable LEDs. This design avoids direct contact of LEDs with the brain tissue and thus does not require electrical and heat isolation, which can non-specifically stimulate and damage the local brain regions. The intensity, frequency, and duty cycle of light pulses from each fiber in the array was controlled independently using an inhouse developed LabView based program interfaced with a microcontroller driving the individual LEDs. While the temporal profile of the light pulses was controlled by varying the current driving the LED, the beam profile emanating from each fiber tip could be sculpted by microfabrication of the fiber tip. The fiber array was used to stimulate neurons, expressing channelrhodopsin-2, in different locations within the brain or retina. Control of neural activity in the mice cortex, using the fiber-array based prosthetic, is evaluated from recordings made with multi-electrode array (MEA). We also report construction of a μLED array based prosthetic for spatio-temporal stimulation of cortex.

  13. Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

    Science.gov (United States)

    Tarroni, Giacomo; Tersi, Luca; Corsi, Cristiana; Stagni, Rita

    2012-06-01

    A new method for prosthetic component segmentation from fluoroscopic images is presented. The hybrid approach we propose combines diffusion filtering, region growing and level-set techniques without exploiting any a priori knowledge of the analyzed geometry. The method was evaluated on a synthetic dataset including 270 images of knee and hip prosthesis merged to real fluoroscopic data simulating different conditions of blurring and illumination gradient. The performance of the method was assessed by comparing estimated contours to references using different metrics. Results showed that the segmentation procedure is fast, accurate, independent on the operator as well as on the specific geometrical characteristics of the prosthetic component, and able to compensate for amount of blurring and illumination gradient. Importantly, the method allows a strong reduction of required user interaction time when compared to traditional segmentation techniques. Its effectiveness and robustness in different image conditions, together with simplicity and fast implementation, make this prosthetic component segmentation procedure promising and suitable for multiple clinical applications including assessment of in vivo joint kinematics in a variety of cases.

  14. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  15. May one-stage exchange for Candida albicans peri-prosthetic infection be successful?

    Science.gov (United States)

    Jenny, J-Y; Goukodadja, O; Boeri, C; Gaudias, J

    2016-02-01

    Fungal infection of a total joint arthroplasty has a low incidence but is generally considered as more difficult to cure than bacterial infection. As for bacterial infection, two-stage exchange is considered as the gold standard of treatment. We report two cases of one-stage total joint exchange for fungal peri-prosthetic infection with Candida albicans, where the responsible pathogens was only identified on intraoperative samples. This situation can be considered as a one-stage exchange for fungal peri-prosthetic infection without preoperative identification of the responsible organism, which is considered as having a poor prognosis. Both cases were free of infection after two years. One-stage revision has several potential advantages over two-stage revision, including shorter hospital stay and rehabilitation, no interim period with significant functional impairment, shorter antibiotic treatment, better functional outcome and probably lower costs. We suggest that one-stage revision for C. albicans peri-prosthetic infection may be successful even without preoperative fungal identification. Level IV-Historical cases. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Early prosthetic valve endocarditis caused by Corynebacterium kroppenstedtii.

    Science.gov (United States)

    Hagemann, Jürgen Benjamin; Essig, Andreas; Herrmann, Manuel; Liebold, Andreas; Quader, Mohamed Abo

    2015-12-01

    Corynebacterium (C.) kroppenstedtii is a rarely detected agent of bacterial infections in humans. Here, we describe the first case of prosthetic valve endocarditis caused by C. kroppenstedtii. Application of molecular methods using surgically excised valve tissue was a cornerstone for the establishment of the microbiological diagnosis, which is crucial for targeted antimicrobial treatment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  17. Autologous alternative veins may not provide better outcomes than prosthetic conduits for below-knee bypass when great saphenous vein is unavailable.

    Science.gov (United States)

    Avgerinos, Efthymios D; Sachdev, Ulka; Naddaf, Abdallah; Doucet, Dannielle R; Mohapatra, Abhisekh; Leers, Steven A; Chaer, Rabih A; Makaroun, Michel S

    2015-08-01

    There is a need to better define the role of alternative autologous vein (AAV) segments over contemporary prosthetic conduits in patients with critical limb ischemia when great saphenous vein (GSV) is not available for use as the bypass conduit. Consecutive patients who underwent bypass to infrageniculate targets between 2007 and 2011 were categorized in three groups: GSV, AAV, and prosthetic. The primary outcome was graft patency. The secondary outcome was limb salvage. Cox proportional hazards regression was used to adjust for baseline confounding variables. A total of 407 infrainguinal bypasses to below-knee targets were analyzed; 255 patients (63%) received a single-segment GSV, 106 patients (26%) received an AAV, and 46 patients (11%) received a prosthetic conduit. Baseline characteristics were similar among groups, with the exception of popliteal targets and anticoagulation use being more frequent in the prosthetic group. Primary patency at 2 and 5 years was estimated at 47% and 32%, respectively, for the GSV group; 24% and 23% for the AAV group; and 43% and 38% for the prosthetic group. Primary assisted patency at 2 and 5 years was estimated at 71% and 55%, respectively, for the GSV group; 53% and 51% for the AAV group; and 45% and 40% for the prosthetic group. Secondary patency at 2 and 5 years was estimated at 75% and 60%, respectively, for the GSV group; 57% and 55% for the AAV group; and 46% and 41% for the prosthetic group. In Cox analysis, primary patency (hazard ratio [HR], 0.55; P < .001; 95% confidence interval [CI], 0.404-0.758), primary assisted patency (HR, 0.57; P = .004; 95% CI, 0.388-0.831), and secondary patency (HR, 0.56; P = .005; 95% CI, 0.372-0.840) were predicted by GSV compared with AAV, but there was no difference between AAV and prosthetic grafts except for the primary patency, for which prosthetic was protective (HR, 0.38; P < .001; 95% CI, 0.224-0.629). Limb salvage was similar among groups. AAV conduits may not offer a significant

  18. SimDialog: A visual game dialog editor

    OpenAIRE

    Owen, C.; Biocca, F.; Bohil, C.; Conley, J.

    2008-01-01

    SimDialog is a visual editor for dialog in computer games. This paper presents the design of SimDialog, illustrating how script writers and non-programmers can easily create dialog for video games with complex branching structures and dynamic response characteristics. The system creates dialog as a directed graph. This allows for play using the dialog with a state-based cause and effect system that controls selection of non-player character responses and can provide a basic scoring mechanism ...

  19. From the Editor Vol: 6 number 2

    OpenAIRE

    Ugur Demiray

    2005-01-01

    From the Editor Dear TOJDES Readers Time flies. Another quarter has begun. It is a great pleasure to welcome you to the 18th issue, the Volume: 6, Number: 2 of The Turkish Online Journal of Distance Education (TOJDE), of looking forward. TOJDE has been driving and shaping by our editorial board, reviewers, authors and even unbelievable readers. In the April 2005 issue, TOJDE publishes peer-reviewed distance education articles under four umbrellas: applications, feature topics, researches, ...

  20. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    Science.gov (United States)

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  1. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Pre prosthetic reconstruction of alveolar ridge

    Directory of Open Access Journals (Sweden)

    Prabhuji Munivenkatappa Lakshmaiahenkatesh

    2011-01-01

    Full Text Available Dento-alveolar bony defects are common and occur due to a variety of causes, such as, pulpal pathology, traumatic tooth extraction, advanced periodontal disease, implant failure, tumor or congenital anomalies. These defects often cause a significant problem in dental treatment and rehabilitation. Many techniques exist for effective soft and hard tissue augmentation. The approach is largely based on the extent of the defect and specific procedures to be performed for the implant or prosthetic rehabilitation. This article presents case reports of soft and hard tissue ridge augmentation.

  3. Andrij Makuch and Frank E. Sysyn, editors. Contextualizing the Holodomor: The Impact of Thirty Years of Ukrainian Famine Studies

    Directory of Open Access Journals (Sweden)

    Johnathon Vsetecka

    2017-03-01

    Full Text Available Book review of Andrij Makuch and Frank E. Sysyn, editors. Contextualizing the Holodomor: The Impact of Thirty Years of Ukrainian Famine Studies. Canadian Institute of Ukrainian Studies P, 2015. viii, 128 pp. $24.95, paper. Conference papers first published in East/West: Journal of Ukrainian Studies, editor-in-chief, Oleh S. Ilnytzkyj, guest editors, Frank Sysyn and Andrij Makuch, vol. 2, no. 1, 2015, pp. 3-132.

  4. Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, I.Chen [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Lin, Yung-Kai; Chang, Yen; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen [Taichung Veterans General Hospital, Section of Cardiovascular Surgery, Cardiovascular Center, Taichung (China); Fu, Yun-Ching; Jan, Sheng-Ling [Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Taichung Veterans General Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Taichung (China); Wang, Kuo-Yang [Taichung Veterans General Hospital, Section of General Cardiology, Cardiovascular Center, Taichung (China); Chung-Shan Medical University, Department of Medicine, Taichung (China); Chen, Min-Chi; Chen, Clayton Chi-Chang [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Central Taiwan University of Science and Technology, Department of Radiological Technology, Taichung (China)

    2009-04-15

    The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders. (orig.)

  5. Magazine or journal--what is the difference? The role of the monitoring editor.

    Science.gov (United States)

    Bretscher, Anthony

    2013-04-01

    Scientific communication, career advancement, and funding decisions are all dependent on research publications. The way manuscripts are handled by high-visibility, professionally edited magazines differs from the way academic journals evaluate manuscripts, using active scientists as monitoring editors. In this essay, I discuss the benefits that come with the involvement of active scientists. I enumerate the decisions a monitoring editor has to make, and how he or she goes about making them. Finally, I indicate ways in which authors can help to make the process a smoother and more positive experience.

  6. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  7. A pulsatile flow model for in vitro quantitative evaluation of prosthetic valve regurgitation

    Directory of Open Access Journals (Sweden)

    S. Giuliatti

    2000-03-01

    Full Text Available A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

  8. Development and preliminary evaluation of a new anatomically based prosthetic alignment method for below-knee prosthesis.

    Science.gov (United States)

    Tafti, Nahid; Karimlou, Masoud; Mardani, Mohammad Ali; Jafarpisheh, Amir Salar; Aminian, Gholam Reza; Safari, Reza

    2018-04-20

    The objectives of current study were to a) assess similarities and relationships between anatomical landmark-based angles and distances of lower limbs in unilateral transtibial amputees and b) develop and evaluate a new anatomically based static prosthetic alignment method. First sub-study assessed the anthropometrical differences and relationships between the lower limbs in the photographs taken from amputees. Data were analysed via paired t-test and regression analysis. Results show no significant differences in frontal and transverse planes. In the sagittal plane, the anthropometric parameters of the amputated limb were significantly correlated to the corresponding variables of the sound limb. The results served as bases for the development of a new prosthetic alignment method. The method was evaluated on a single subject study. Prosthetic alignment carried out by an experienced prosthetist was compared with such alignment adjusted by an inexperienced prosthetist but with the use of the developed method. In sagittal and frontal planes, the socket angle was tuned with respect to the shin angle, and the position of the prosthetic foot was tuned in relation to the pelvic landmarks. Further study is needed to assess the proposed method on a larger sample of amputees and prosthetists.

  9. Prosthetic vision: devices, patient outcomes and retinal research.

    Science.gov (United States)

    Hadjinicolaou, Alex E; Meffin, Hamish; Maturana, Matias I; Cloherty, Shaun L; Ibbotson, Michael R

    2015-09-01

    Retinal disease and its associated retinal degeneration can lead to the loss of photoreceptors and therefore, profound blindness. While retinal degeneration destroys the photoreceptors, the neural circuits that convey information from the eye to the brain are sufficiently preserved to make it possible to restore sight using prosthetic devices. Typically, these devices consist of a digital camera and an implantable neurostimulator. The image sensor in a digital camera has the same spatiotopic arrangement as the photoreceptors of the retina. Therefore, it is possible to extract meaningful spatial information from an image and deliver it via an array of stimulating electrodes directly to the surviving retinal circuits. Here, we review the structure and function of normal and degenerate retina. The different approaches to prosthetic implant design are described in the context of human and preclinical trials. In the last section, we review studies of electrical properties of the retina and its response to electrical stimulation. These types of investigation are currently assessing a number of key challenges identified in human trials, including stimulation efficacy, spatial localisation, desensitisation to repetitive stimulation and selective activation of retinal cell populations. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  10. Uptake of radiolabeled leukocytes in prosthetic graft infection

    International Nuclear Information System (INIS)

    Serota, A.I.; Williams, R.A.; Rose, J.G.; Wilson, S.E.

    1981-01-01

    The utility of radionuclide labeled leukocytes in the demonstration of infection within vascular prostheses was examined. The infrarenal aorta was replaced with a 3 cm Dacron graft in 12 dogs. On the third postoperative day, six of the animals received an intravenous injection of 10(8) Staphylococcus aureus. Labeled leukocyte scans were performed at postoperative days one and three, and then weekly for 8 weeks with indium-111 and technetium-99 labeled autologous leukocytes. When scans showed focal uptake of isotope in the area of prosthetic material, the grafts were aseptically excised and cultured on mannitol-salt agar. Both control and infected animals had retroperitoneal isotope activity in the immediate postoperative period that disappeared by the end of the first week. By the eighth postoperative week, all of the animals that received the bacteremic challenge had both radionuclide concentration in the region of the vascular prosthesis and S. aureus cultured subsequently from the perigraft tissues. None of the control animals had either radionuclide or bacteriologic evidence of infection at the eighth postoperative week. The radiolabeled leukocyte scan is a highly sensitive and specific technique, clinically applicable for the diagnosis of vascular prosthetic infections

  11. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    Science.gov (United States)

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  12. Evaluation of p53 Polymorphism in Patients with Pannus-Derived Prosthetic Dysfunction.

    Science.gov (United States)

    Gursoy, Mustafa Ozan; Karakoyun, Suleyman; Kalcik, Macit; Yesin, Mahmut; Gunduz, Sabahattin; Astarcioğlu, Mehmet Ali; Oğuz, Ali Emrah; Ozkan, Mehmet

    2015-09-01

    Prosthetic valve dysfunction (PVD) due to pannus formation is considered to occur due to a bioreaction to prosthetic material. The p53 gene plays a critical role in apoptosis and cell proliferation. p53 Arg72Pro polymorphism has been found to be associated with coronary stent restenosis, but has not yet been studied in prosthetic heart valve dysfunction. The study aim was to evaluate the association between pannus-derived PVD and p53 G72C(Arg72Pro) polymorphism. This single-center, prospective study included 25 patients (20 females, five males; mean age 45.6 +/- 12.5 years; group 1) who underwent redo valve surgery due to PVD, and 49 age- and gender-matched control patients (44 females, five males; mean age 47.3 +/- 12.2 years; group 2) with normofunctional prostheses. The prostheses were examined using transthoracic and transesophageal echocardiography. Analyses of p53 G72C(Arg72Pro) polymorphism were performed using Roche LightCyler 2.0 Real-time polymerase chain reaction. The most common location of replaced valves was the mitral position in both groups (88% and 89.8%, respectively). In group 1, normal alleles (GG) were observed in 12 patients (48%), while one patient (4%) showed a homozygous mutation (GC) and 12 patients (48%) showed a heterozygous mutation (CC). In group 2, 21 patients (42.9%) had normal alleles (GG), while four (8.2%) had a homozygous mutation (CC) and 24 (48.9%) had a heterozygous mutation (GC). No significant difference was observed between the groups with regards to p53 Arg72Pro polymorphism (p = 0.769). In patients with prosthetic valves, the underlying mechanism behind pannus formation is unrelated to p53 Arg72Pro polymorphism.

  13. Forward by Guest Editors | Potgieter | African Journal on Conflict ...

    African Journals Online (AJOL)

    African Journal on Conflict Resolution. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 15, No 3 (2015) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Forward by Guest Editors. Cheryl Potgieter, Paulus ...

  14. 77 FR 74175 - Solicitation of Review Editors for the Draft Report of the National Climate Assessment and...

    Science.gov (United States)

    2012-12-13

    ... Climate Change Science; The NCA Long-Term Process. Dated: December 6, 2012. Jason Donaldson, Chief Financial Officer/Chief Administrative Officer, Office of Oceanic and Atmospheric Research, National Oceanic... Assessment 2013 Draft Report. Review Editor Role In the NCA Process: One Review Editor for each NCA 2013...

  15. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Science.gov (United States)

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  16. Mary Shelley as editor of Percy Shelley

    OpenAIRE

    Allen, Richard

    2001-01-01

    This chapter explores Mary Shelley's work as the founding editor of Percy Shelley's poetry. It sets out the circumstances of Mary Shelley's life after the death of Percy Shelley, her financial dependence on Percy Shelley's father, and the restrictions placed on publication by Shelley's father. It then sets out the strategies Mary Shelley used to construct a biography of Percy Shelley from the poem, thus establishing a Romantic biography of Percy Shelley which has endured into the 20th century,

  17. Guest editor

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-07-15

    Full text: Guest Editor for this special issue of the CERN Courier on the applications of accelerators was Dewi M. Lewis of Amersham International pic, UK. Dr. Lewis was educated at the Physics Department, University of Wales, Swansea, and learnt his accelerator physics as Engineer-in- Charge at the CERN Intersecting Storage Rings before joining industry in 1979 at the beginning of the boom for commercial cyclotrons. Having managed the installation of Amersham's second and third isotope production cyclotrons in the UK, his industrial experience encompassed isotope manufacturing and business management in radiopharmaceuticals and organization of joint ventures. Following closure of several research reactors in 1990, his responsibilities extended to reactor isotope production as well as technology transfer with international laboratories. He was responsible for creation of the first Russian 'weapons to ploughshares' joint venture with the Radioisotope Association, Mayak and the Russian Atomic Energy Ministry. Dr. Lewis currently chairs the European Radiopharmaceutical Industry's committee on future reactor isotopes and is currently involved in the technical development for accelerator technology. Amersham International is one of the world's leading isotope companies, engaged in development, manufacturing, international sales and distribution of radioisotope products in markets for healthcare, research compounds and industrial products. Formerly part of the United Kingdom Atomic Energy Agency, Amersham was one of the first companies to be privatized in 1982.

  18. Guest editor

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Full text: Guest Editor for this special issue of the CERN Courier on the applications of accelerators was Dewi M. Lewis of Amersham International pic, UK. Dr. Lewis was educated at the Physics Department, University of Wales, Swansea, and learnt his accelerator physics as Engineer-in- Charge at the CERN Intersecting Storage Rings before joining industry in 1979 at the beginning of the boom for commercial cyclotrons. Having managed the installation of Amersham's second and third isotope production cyclotrons in the UK, his industrial experience encompassed isotope manufacturing and business management in radiopharmaceuticals and organization of joint ventures. Following closure of several research reactors in 1990, his responsibilities extended to reactor isotope production as well as technology transfer with international laboratories. He was responsible for creation of the first Russian 'weapons to ploughshares' joint venture with the Radioisotope Association, Mayak and the Russian Atomic Energy Ministry. Dr. Lewis currently chairs the European Radiopharmaceutical Industry's committee on future reactor isotopes and is currently involved in the technical development for accelerator technology. Amersham International is one of the world's leading isotope companies, engaged in development, manufacturing, international sales and distribution of radioisotope products in markets for healthcare, research compounds and industrial products. Formerly part of the United Kingdom Atomic Energy Agency, Amersham was one of the first companies to be privatized in 1982

  19. Conceptual design of a generic pulse schedule and event handling editor for improved fusion device operation

    International Nuclear Information System (INIS)

    Barana, Oliviero; Nouailletas, Rémy; Brémond, Sylvain; Moreau, Philippe; Allegretti, Ludovic; Balme, Stéphane; Ravenel, Nathalie; Mannori, Simone; Guillerminet, Bernard; Leroux, Fabrice; Douai, David; Nardon, Eric; Hertout, Patrick; Saint-Laurent, François

    2013-01-01

    Highlights: ► Real-time event handling requires extended functionalities of pulse schedule editors and plasma control systems ► A new pulse schedule editor, conceived for parameterization of systematic off-normal event handling, is described ► A global, generic approach on off-normal event handling is highlighted ► The functional architecture of an off-normal event handling oriented plasma control system is discussed ► The main objects of the pulse schedule editor are the segment-descriptor object and the scenario-descriptor object. -- Abstract: Coping with unexpected events is an important issue of nuclear fusion experiments. The future machines, characterized by very long plasma discharges and actively cooled metallic plasma-facing components, will require a systematic intervention in real time, in order to maximize the performance and protect the investment. The real-time management of events will require extending the functionalities of the current pulse schedule editors with the possibility of using reference waveforms provided with acceptability margins and setting up advanced mitigation strategies and event countermeasures. With this purpose, a new pulse schedule editor, based on a time-segment approach for the preparation of experimental scenarios, is being conceived on Tore Supra, together with a new plasma control system. This paper will report on their conceptual design and give account of the preliminary results of a feasibility study currently under way in order to prepare a possible implementation on Tore Supra

  20. Conceptual design of a generic pulse schedule and event handling editor for improved fusion device operation

    Energy Technology Data Exchange (ETDEWEB)

    Barana, Oliviero, E-mail: oliviero.barana@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez Durance (France); Nouailletas, Rémy; Brémond, Sylvain; Moreau, Philippe; Allegretti, Ludovic; Balme, Stéphane; Ravenel, Nathalie [CEA, IRFM, F-13108 Saint-Paul-Lez Durance (France); Mannori, Simone [ENEA C.R. Brasimone, 40032 Camugnano (Italy); Guillerminet, Bernard; Leroux, Fabrice; Douai, David; Nardon, Eric; Hertout, Patrick; Saint-Laurent, François [CEA, IRFM, F-13108 Saint-Paul-Lez Durance (France)

    2013-10-15

    Highlights: ► Real-time event handling requires extended functionalities of pulse schedule editors and plasma control systems ► A new pulse schedule editor, conceived for parameterization of systematic off-normal event handling, is described ► A global, generic approach on off-normal event handling is highlighted ► The functional architecture of an off-normal event handling oriented plasma control system is discussed ► The main objects of the pulse schedule editor are the segment-descriptor object and the scenario-descriptor object. -- Abstract: Coping with unexpected events is an important issue of nuclear fusion experiments. The future machines, characterized by very long plasma discharges and actively cooled metallic plasma-facing components, will require a systematic intervention in real time, in order to maximize the performance and protect the investment. The real-time management of events will require extending the functionalities of the current pulse schedule editors with the possibility of using reference waveforms provided with acceptability margins and setting up advanced mitigation strategies and event countermeasures. With this purpose, a new pulse schedule editor, based on a time-segment approach for the preparation of experimental scenarios, is being conceived on Tore Supra, together with a new plasma control system. This paper will report on their conceptual design and give account of the preliminary results of a feasibility study currently under way in order to prepare a possible implementation on Tore Supra.