WorldWideScience

Sample records for echocardiography tissue doppler

  1. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  2. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  3. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  4. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  5. Evaluation of regional wall motion abnormalities of the heart. Comparison with Doppler tissue echocardiography, MR-tagging and levocardiography

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Hamm, B.; Borges, A.C.; Walde, T.; Rutsch, W.; Baumann, G.

    2004-01-01

    Purpose: To compare the visual analysis of magnetic resonance imaging (MRI) with the tagging technique and Doppler tissue echocardiography with invasive ventriculography in detecting and quantifying regional left ventricular wall motion abnormalities. Materials and Methods: Sixteen patients with coronary artery disease and a history of prior myocardial infarction underwent invasive ventriculography. Doppler tissue echocardiography and MR-tagging within one week. Regional wall motion abnormalities (WMA) were detected in all patients. WMA were graded as normal=1; hypokinetic=2; akinetic=3; or dyskinetic=4. For agreement between MRI, echocardiography, and ventriculography the kappa coefficient (κ) according to Cohen was calculated. Results: The kappa coefficient (κ) was 0.962 for agreement between MRI and echocardiography and 0.602 for agreement between MRI and ventriculography as well as between echocardiography and ventriculography. Conclusion: Reliable analysis of regional left ventricular wall motion abnormalities is feasible using visual analysis of MR-tagging. MRI and Doppler tissue echocardiography detect more WMA than invasive ventriculography and grade them as more severe. (orig.)

  6. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  7. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  8. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  9. Tissue Doppler echocardiography reveals impaired cardiac function in patients with reversible ischaemia

    DEFF Research Database (Denmark)

    Hoffmann, Søren; Mogelvang, Rasmus; Sogaard, Peter

    2011-01-01

    AIMS: To determine if echocardiographic tissue Doppler imaging (TDI) performed at rest detects reduced myocardial function in patients with reversible ischaemia. METHODS AND RESULTS: Eighty-four patients with angina pectoris, no previous history of ischaemic heart disease and normal left ventricu...

  10. Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Directory of Open Access Journals (Sweden)

    Sicari Rosa

    2005-01-01

    Full Text Available Abstract In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories.

  11. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  12. Tissue Doppler echocardiography improves the diagnosis of coronary artery stenosis in stable angina pectoris

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Jensen, Jan Skov; Iversen, Allan Zeeberg

    2012-01-01

    Aim To determine if colour tissue Doppler imaging (TDI) performed at rest in patients with suspected stable angina pectoris (SAP) is able to predict the presence of significant coronary artery disease (CAD). METHODS AND RESULTS: This study comprises 296 consecutive patients with clinically...... by colour TDI at six mitral annular sites and averaged to provide global estimates. Duke score (DS), including ST depression, chest pain, and exercise capacity, was used as the outcome of the exercise ECG. Patients with an area stenosis of ≥70% in at least one epicardial coronary artery were categorized...

  13. Tissue Doppler echocardiography in persons with hypertension, diabetes, or ischaemic heart disease: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Mogelvang, Rasmus; Sogaard, Peter; Pedersen, Sune A

    2009-01-01

    AIMS: To test the hypothesis that echocardiographic tissue Doppler imaging (TDI) reveals reduced myocardial function in hypertension, diabetes, and ischaemic heart disease (IHD) in the general population. METHODS AND RESULTS: Within a large, community-based population study, cardiac function...... and diastolic cardiac function in hypertension [n = 345; LD 10.1 (+/-standard deviation, SD 2.0 mm), P diabetes [n = 65; LD 9.8 (+/-SD 2.2 mm), P ....001] compared with controls [n = 533; LD 11.4 (+/-SD 2.0 mm); E/e' 9.0 (x/SD 1.3)]. This pattern remained significant after adjusting for age, sex, body mass index, heart rate, and the results of conventional echocardiography. CONCLUSION: In the general population, persons with hypertension, diabetes, or IHD...

  14. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    Science.gov (United States)

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P closure (P closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  15. Predicting Paroxysmal Atrial Fibrillation in Cerebrovascular Ischemia Using Tissue Doppler Imaging and Speckle Tracking Echocardiography

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Jørgensen, Peter Godsk; Møgelvang, Rasmus

    2016-01-01

    BACKGROUND: Often the underlying cause of cerebral ischemia (CI) cannot be found during a routine diagnostic investigation, but paroxysmal atrial fibrillation (PAF) could be the culprit. AIM: The objective of the study is to investigate whether advanced echocardiography improves the diagnostic ap...

  16. Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major.

    Science.gov (United States)

    Saravi, Mehrdad; Tamadoni, Ahmad; Jalalian, Rozita; Mahmoodi-Nesheli, Hassan; Hojati, Mosatafa; Ramezani, Saeed

    2013-01-01

    Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard non-invasive diagnostic test. A total of 100 TM patients with the mean age of 19±7 years and 100 healthy controls 18.8±7 years were evaluated. Conventional echocardiography, TDI, and cardiac MRI T2* were performed in all subjects. TDI measures included myocardial systolic (Sm), early (Em) and late (Am) diastolic velocities at basal and middle segments of septal and lateral LV wall. The TM patients were also subgrouped according to those with iron load (T2* ≤ 20 ms) and those without (T2* > 20 ms), and also severe (T2* ≤ 10 ms) versus the non-severe (T2* ≤ 10 ms). Using T2* cardiovascular MR, abnormal myocardial iron load (T2* ≤ 20 ms) was detected in 84% of the patients and among these, 50% (42/84) had severe (T2* ≤ 10 ms) iron load. The mean T2* was 11.6±8.6 ms (5-36.7). A negative linear correlation existed between transfusion period of patients and T2* levels (r = -0.53, p=0.02). The following TDI measures were lower in patients than in controls: basal septal Am (p<0.05), mid-septal Em and Am (p<0.05), basal lateral Am (p<0.05), mid-lateral LV wall Sm (p<0.05) and Am (p<0.05). Tissue doppler imaging is helpful in predicting the presence of myocardial iron load in Thalassemia patients. Therefore, it can be used for screening of thalassemia major patients.

  17. Tissue Doppler echocardiography reveals distinct patterns of impaired myocardial velocities in different degrees of coronary artery disease

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Mogelvang, Rasmus; Olsen, Niels Thue

    2010-01-01

    Aim To determine how the left ventricular wall motion assessed by echocardiographic Tissue Doppler Imaging (TDI) is affected by increasing severity of coronary artery disease (CAD) among patients with stable angina pectoris and preserved ejection fraction. METHODS AND RESULTS: This study comprise...

  18. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  19. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  20. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  1. Estimation of diastolic filling pressure with cardiac CT in comparison with echocardiography using tissue doppler imaging: Determination of optimal CT reconstruction parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Sun; Suh, Jon; Lee, Heon [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of); Lee, Bora [Dept. of Biostatistics, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University Hospital Cheonan, Cheonan (Korea, Republic of); Lim, Hyun Kyung [Dept. of Radiology, Soonchunhyang University Hospital Seoul, Seoul (Korea, Republic of)

    2017-08-01

    To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′. Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm{sup 2}). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography. For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.

  2. Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography: A New Alternative in the Assessment of the Segmental Ventricular Function

    Directory of Open Access Journals (Sweden)

    Silva Carlos Eduardo Suaide

    2002-01-01

    Full Text Available OBJECTIVE: Doppler tissue imaging (DTI enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male with ages ranging from 12 to 59 years (32.9 ± 10.6. Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls were respectively, in cm/s, 7.35(1.64, 5.26(1.88, and 3.33(1.58 in systole and 10.56(2.34, 7.92(2.37, and 3.98(1.64 in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms, and diastolic was 459.18ms (±18.13ms based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05. The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.

  3. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  4. Assessment of strain and strain rate by two-dimensional speckle tracking in mice: comparison with tissue Doppler echocardiography and conductance catheter measurements.

    Science.gov (United States)

    Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J

    2013-08-01

    This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.

  5. Dobutamine Stress Echocardiography and Tissue Synchronization Imaging

    Science.gov (United States)

    Tas, Hakan; Gundogdu, Fuat; Gurlertop, Yekta; Karakelleoglu, Sule

    2008-01-01

    Dobutamine stress echocardiography has emerged as a reliable method for the diagnosis of coronary artery disease and the management of its treatment. Several studies have shown that that this technique works with 80–85% accuracy in comparison with other imaging methods. There are few studies aimed at developing the clinical utility of dobutamine stress echocardiography for the evaluation of normal and abnormal segments that result from dobutamine stress with Tissue Synchronization Imaging. PMID:25610034

  6. Right heart function in impaired left ventricular diastolic function: 2D speckle tracking echocardiography-based and Doppler tissue imaging-based analysis of right atrial and ventricular function.

    Science.gov (United States)

    Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk

    2018-01-01

    The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.

  7. [Pulmonary artery pressure evaluation in adults by Doppler echocardiography].

    Science.gov (United States)

    Campos Filho, O; Andrade, J L; Carvalho, A C; Luna Filho, B; Pfeferman, A; Arroyo, J B; Leão, L E; Martinez Filho, E E

    1991-04-01

    To assess the role of pulsed Doppler echocardiography (PDE) in the indirect assessment of pulmonary artery (PA) pressure (P), analysing the pulmonary velocity blood flow curves (PVBFC) profile. Sixty-one adults with several kinds of heart disease were submitted to heart catheterization to obtain PAP (systolic, diastolic, mean), and other hemodynamic variables. A PDE examination was performed in all to obtain the PVBFC at the level of the pulmonic annulus. Qualitative features of the curve were analysed (morphological pattern, presence of pulmonic regurgitation) as well as quantitative data (acceleration time = AT, right ventricle ejection time = RVET index, AT/RVET index AT corrected for heart rate = ATC), which were compared to the invasive measurements. An abnormal rapid acceleration of the PVBFC, with triangular configuration, was noted in patient with pulmonary hypertension (PH), in contrast to the dome-like shape of the PVBFC in normal PAP. Pulmonary regurgitation was more frequent (p less than 0.05) in patients with severe PH (mean PAP greater than or equal to 40 mmHg), comparing with patients with PAP less than 40 mmHg. Inverse linear correlations were observed between AT and mean PAP, particularly when sinus rhythm was present (r = 0.89; p less than 0.05) excluding patients with atrial fibrilation (19 cases). PDE is an useful and noninvasive method for indirect evaluation of PAP in adults, especially during stable sinus rhythm, in heart rate range from 60 to 115 bpm.

  8. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  9. [Doppler echocardiography of tricuspid insufficiency. Methods of quantification].

    Science.gov (United States)

    Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P

    1994-01-01

    Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.

  10. Ecocardiografia por Doppler tecidual no diagnóstico de rejeição após transplante cardíaco Ecocardiografía con Doppler tisular en el diagnóstico de rechazo después de transplante cardíaco Tissue doppler echocardiography in the diagnosis of heart transplantation rejection

    Directory of Open Access Journals (Sweden)

    Marcos Valério Coimbra Resende

    2011-07-01

    ,3%, especificidad de 73,8% (p = 0,001. En el análisis multivariado, la a'LAT (p = 0,001, a'SEP (p = 0,002, relación e'/a' LAT (p = 0,006, relación e'Mitral/e'LAT (p = 0,014, SINF (p = 0,009 fueron predictores de RC > 3A. Obtuvimos un escore con sensibilidad de 88,2%, precisión de 79,6%, y valor predictivo negativo de 92.9% para diagnosticar RC > 3A . El Doppler convencional (flujo mitral y pulmonar venoso no fue relevante para predecir la RC > 3A. CONCLUSIÓN: El estudio de IDT agregó información diagnóstica para predecir RC > 3A cuando fue comparado al Doppler convencional. El modelo basado en IDT puede volverse un método en potencial para detectar RC > 3A después de TC.BACKGROUND: Endomyocardial biopsy (EMB is the gold standard method for the diagnosis of cellular rejection (CR after heart transplantation (HT. OBJECTIVE: To test the hypothesis that tissue Doppler imaging (TDI could detect CR > 3A and add diagnostic information compared to conventional Doppler. METHODS: Fifty-four HT patients underwent 129 EMB and a TDI echocardiographic study within 24 hours. We compared HT patients with CR > 3A versus HT patients with CR 3A in 39/129 (30.2% EMB. The best isolated predictor for CR diagnosis was a'LAT, with a sensitivity of 76.3%, specificity of 73.8% (p = 0.001. In the multivariate analysis, a'LAT (p = 0.001, a'SEP (p = 0.002, e'/a' LAT ratio (p = 0.006, e'Mitral/ e'LAT ratio (p = 0.014, SINF (p = 0.009 predicted CR > 3A. We obtained a score with a sensitivity of 88.2%, accuracy of 79.6% and negative predictive value of 92.9% to diagnose CR > 3A. Conventional Doppler (mitral and pulmonary venous flow was not relevant to predict CR > 3A. CONCLUSION: TDI added diagnostic information to predict CR > 3A compared to conventional Doppler. A TDI-based model could become a potential method to detect CR > 3A after Heart Transplantation.

  11. Utility of Angle Correction for Hemodynamic Measurements with Doppler Echocardiography.

    Science.gov (United States)

    Sigurdsson, Martin I; Eoh, Eun J; Chow, Vinca W; Waldron, Nathan H; Cleve, Jayne; Nicoara, Alina; Swaminathan, Madhav

    2018-04-06

    The routine application angle correction (AnC) in hemodynamic measurements with transesophageal echocardiography currently is not recommended but potentially could be beneficial. The authors hypothesized that AnC can be applied reliably and may change grading of aortic stenosis (AS). Retrospective analysis. Single institution, university hospital. During phase I, use of AnC was assessed in 60 consecutive patients with intraoperative transesophageal echocardiography. During phase II, 129 images from a retrospective cohort of 117 cases were used to quantify AS by mean pressure gradient. A panel of observers used custom-written software in Java to measure intra-individual and inter-individual correlation in AnC application, correlation with preoperative transthoracic echocardiography gradients, and regrading of AS after AnC. For phase I, the median AnC was 21 (16-35) degrees, and 17% of patients required no AnC. For phase II, the median AnC was 7 (0-15) degrees, and 37% of assessed images required no AnC. The mean inter-individual and intra-individual correlation for AnC was 0.50 (95% confidence interval [CI] 0.49-0.52) and 0.87 (95% CI 0.82-0.92), respectively. AnC did not improve agreement with the transthoracic echocardiography mean pressure gradient. The mean inter-rater and intra-rater agreement for grading AS severity was 0.82 (95% CI 0.81-0.83) and 0.95 (95% CI 0.91-0.95), respectively. A total of 241 (7%) AS gradings were reclassified after AnC was applied, mostly when the uncorrected mean gradient was within 5 mmHg of the severity classification cutoff. AnC can be performed with a modest inter-rater and intra-rater correlation and high degree of inter-rater and intra-rater agreement for AS severity grading. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Basic indications for the performance of Color Doppler echocardiography

    International Nuclear Information System (INIS)

    Manzur, Fernando; Olivo, Carlos

    2005-01-01

    Clinical practice based on evidence takes off emphasis in intuition; clinical experience and rational physiopathology give sufficient bases for the clinical decision assessment and emphasizes the evidence's examination for the clinical investigation. The comprehension of certain evidence rules is necessary for the correct interpretation of literature in respect to the causes, diagnostic tools and treatment strategies. The main aim of this research is to make a protocol for the indications of an echocardiogram in the clinical practice and to educate our country's general physicians in this conduct. The good practice is due to initiatives, activities and functional models that are in progress worldwide, as confirmed by evidence. Objective: echocardiography is actually the gold standard for the study of heart anatomy and physiology. Since its introduction in the clinical practice more than three decades ago, it has had such diffusion that it is considered an important tool in the cardiology assistance. It provides trustworthy functional anatomic information, as well as diagnosis and is decisive in the treatment and resolution of cardiovascular diseases. The progressive development of this technique has enabled its use in all the different fields that may affect the cardiovascular system. The objective is to help the clinical physicians in the making of decisions in concrete situations, guaranteeing them that the diagnosis is based on results given by valid scientific studies. In accordance to this, different studies as well as task force and management guides representative of the worldwide literature were compiled

  13. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  14. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  15. Cardiac tissue Doppler imaging in sports medicine.

    Science.gov (United States)

    Krieg, Anne; Scharhag, Jürgen; Kindermann, Wilfried; Urhausen, Axel

    2007-01-01

    The differentiation of training-induced cardiac adaptations from pathological conditions is a key issue in sports cardiology. As morphological features do not allow for a clear delineation of early stages of relevant pathologies, the echocardiographic evaluation of left ventricular function is the technique of first choice in this regard. Tissue Doppler imaging (TDI) is a relatively recent method for the assessment of cardiac function that provides direct, local measurements of myocardial velocities throughout the cardiac cycle. Although it has shown a superior sensitivity in the detection of ventricular dysfunction in clinical and experimental studies, its application in sports medicine is still rare. Besides technical factors, this may be due to a lack in consensus on the characteristics of ventricular function in relevant conditions. For more than two decades there has been an ongoing debate on the existence of a supernormal left ventricular function in athlete's heart. While results from traditional echocardiography are conflicting, TDI studies established an improved diastolic function in endurance-trained athletes with athlete's heart compared with controls.The influence of anabolic steroids on cardiac function also has been investigated by standard echocardiographic techniques with inconsistent results. The only TDI study dealing with this topic demonstrated a significantly impaired diastolic function in bodybuilders with long-term abuse of anabolic steroids compared with strength-trained athletes without abuse of anabolic steroids and controls, respectively.Hypertrophic cardiomyopathy is the most frequent cause of sudden death in young athletes. However, in its early stages, it is difficult to distinguish from athlete's heart. By means of TDI, ventricular dysfunction in hypertrophic cardiomyopathy can be disclosed even before the development of left ventricular hypertrophy. Also, a differentiation of left ventricular hypertrophy due to hypertrophic

  16. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  17. Myocardial response to a triathlon in male athletes evaluated by Doppler tissue imaging and biochemical parameters

    DEFF Research Database (Denmark)

    Leetmaa, T H; Dam, A; Glintborg, D

    2008-01-01

    (cTnT) and pro-brain natriuretic peptide (pro-BNP)] and echocardiography. Conventional echocardiography techniques and new Doppler tissue imaging (DTI) modalities were applied before and immediately after the competition. Blood samples were drawn 1 week before, immediately after and 12-24 h post...... and systolic velocities decreased, thus suggesting reversible cardiac fatigue. When using cardiac markers and echocardiographic findings, a triathlon was found to have no significant negative effects on left ventricular function or myocardial tissue in male athletes....

  18. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  19. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  20. Cardiovascular assessment of patients with Ullrich-Turner's Syndrome on Doppler echocardiography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Castro Ana Valéria Barros de

    2002-01-01

    Full Text Available OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta. Their ages ranged from 10 to 28 (mean of 16.7 years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%; 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7, mosaics (n=5, and deletions (n=3. No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively. This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

  1. Cardiac Time Intervals Measured by Tissue Doppler Imaging M-mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Schnohr, Peter

    2016-01-01

    function was evaluated in 1915 participants by using both conventional echocardiography and tissue Doppler imaging (TDI). The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT), and ejection time (ET), were obtained by TDI M-mode through the mitral......). Additionally, they displayed a significant dose-response relationship, between increasing severity of elevated blood pressure and increasing left ventricular mass index (P

  2. Measurement of pulmonary arterial elastance in patients with systolic heart failure using Doppler echocardiography

    Science.gov (United States)

    Taghavi, Sepideh; Esmaeilzadeh, Maryam; Amin, Ahmad; Naderi, Nasim; Abkenar, Hooman Bakhshandeh; Maleki, Majid; Mitra, Chitsazan

    2016-01-01

    Objective: A reliable and easy-to-perform method for measuring right ventricular (RV) afterload is desirable when scheduling patients with systolic heart failure to undergo heart transplantation. The present study aimed to investigate the accuracy of echocardiographically-derived pulmonary arterial elastance as a measurement of pulmonary vascular resistance by comparing it with invasive measures. Methods: Thirty-one patients with moderate to severe systolic heart failure, including 22 (71%) male patients, with a mean age of 41.16±15.9 years were enrolled in the study. Right heart catheterization and comprehensive echocardiography during the first hour after completion of cardiac catheterization were performed in all the patients. The pulmonary artery elastance was estimated using the ratio of end-systolic pressure (Pes) over the stroke volume (SV) by both cardiac catheterization [Ea (PV)-C] and echocardiography [Ea (PV)-E]. Results: The mean Ea (PV)-C and Ea (PV)-E were estimated to be 0.73±0.49 mm Hg/mL and 0.67±0.44 mm Hg/mL, respectively. There was a significant relation between Ea (PV)-E and Ea (PV)-C (r=0.897, pechocardiography and catheterization methods for estimating Ea (PV), investigated by the Bland-Altman method, showed a mean bias of -0.06, with 95% limits of agreement from -0.36 mm Hg/mL to 0.48 mm Hg/mL. Conclusion: Doppler echocardiography is an easy, non-invasive, and inexpensive method for measuring pulmonary arterial elastance, which provides accurate and reliable estimation of RV afterload in patients with systolic heart failure. PMID:26467379

  3. Doppler Echocardiography Assessment of Aortic Stiffness in Female Adolescents with Anorexia Nervosa.

    Science.gov (United States)

    Escudero, Carolina A; Potts, James E; Lam, Pei-Yoong; De Souza, Astrid M; Mugford, Gerald J; Sandor, George G S

    2018-03-17

    Anorexia nervosa (AN) is associated with abnormalities in biomarkers of cardiovascular risk. Arterial stiffness, as measured by pulse-wave velocity (PWV), is also a risk factor for cardiovascular disease. The aims of this study were to determine the stiffness of the aorta in female adolescents with AN and to determine if either the severity or the type of AN was associated with PWV. This was a retrospective case-control study. Adolescent patients with a clinical diagnosis of AN were included. Aortic diameter and pulse-wave transit time over a portion of the thoracic aorta were measured using Doppler echocardiography, and PWV was calculated. There were 94 female patients with AN and 60 adolescent female control subjects. There was no significant difference in age between patients with AN and control subjects (15.5 ± 1.7 vs 15.1 ± 2.6 years, P = .220). Body mass index (16.0 ± 2.4 vs 19.7 ± 2.7 kg/m 2 , P study suggests that patients with AN may be at increased risk for future cardiovascular disease. Future studies are required to determine the reversibility of these changes with weight restoration. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  4. Cardiac output by Doppler echocardiography in the premature baboon: Comparison with radiolabeled microspheres

    International Nuclear Information System (INIS)

    Kinsella, J.P.; Morrow, W.R.; Gerstmann, D.R.; Taylor, A.F.; deLemos, R.A.

    1991-01-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). The authors conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress

  5. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  6. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  7. Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures

    International Nuclear Information System (INIS)

    Ahmed, I.; Nuri, M. M. H.; Zakariyya, A. N.; Ahmad, S. M.; Ahmed, M.

    2016-01-01

    Objective: To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. Methodology: All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. Results: Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ± 15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ± 13.05) and diagnostic accuracy (79%). Conclusion: Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal. (author)

  8. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; de Knegt, Martina Chantal

    2016-01-01

    PURPOSE: To define normal values of the cardiac time intervals obtained by tissue Doppler imaging (TDI) M-mode through the mitral valve (MV). Furthermore, to evaluate the association of the myocardial performance index (MPI) obtained by TDI M-mode (MPITDI) and the conventional method of obtaining...

  9. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  10. Is epicardial adipose tissue, assessed by echocardiography, a reliable method for visceral adipose tissue prediction?

    Science.gov (United States)

    Silaghi, Alina Cristina; Poantă, Laura; Valea, Ana; Pais, Raluca; Silaghi, Horatiu

    2011-03-01

    Epicardial adipose tissue is an ectopic fat storage at the heart surface in direct contact with the coronary arteries. It is considered a metabolically active tissue, being a local source of pro-inflammatory factors that contribute to the pathogenesis of coronary artery disease. The AIM of our study was to establish correlations between echocardiographic assessment of epicardial adipose tissue and anthropometric and ultrasound measurements of the central and peripheral fat depots. The study was conducted on 22 patients with or without coronaropathy. Epicardial adipose tissue was measured using Aloka Prosound α 10 machine with a 3.5-7.5 MHz variable-frequency transducer and subcutaneous and visceral fat with Esaote Megas GPX machine and 3.5-7.5 MHz variable frequency transducer. Epicardial adipose tissue measured by echocardiography is correlated with waist circumference (p < 0.05), visceral adipose tissue thickness measured by ultrasonography (US) and is not correlated with body mass index (p = 0.315), hip and thigh circumference or subcutaneous fat thickness measured by US. Our study confirms that US assessment of epicardial fat correlates with anthropometric and US measurements of the central fat, representing an indirect but reliable marker of the visceral fat.

  11. Evaluation of postoperative pulmonary regurgitation after surgical repair of tetralogy of Fallot: comparison between Doppler echocardiography and MR velocity mapping

    Energy Technology Data Exchange (ETDEWEB)

    Grothoff, Matthias; Spors, Birgit; Gutberlet, Matthias [Charite Campus Virchow Klinikum, Department of Radiology and Nuclear Medicine, Berlin (Germany); Abdul-Khaliq, Hasim [Deutsches Herzzentrum, Department of Congenital Heart Disease/Pediatric Cardiology, Berlin (Germany)

    2008-02-15

    Pulmonary regurgitation is a common finding in patients after correction of tetralogy of Fallot (TOF). Right ventricular impairment and even ventricular arrhythmia have been ascribed to pulmonary valve insufficiency (PI), which is therefore an important issue in follow-up examinations. To compare PI measured by echocardiography (ECHO) with data provided by cardiac MRI (CMR). We studied 54 selected patients (18 female; median age 14.0 years, range 3.8-53.4 years) after surgical correction of TOF. To quantify pulmonary regurgitant fraction (PRF) by CMR, flow velocity mapping was performed. On Doppler ECHO, length, width and localization of regurgitant flow was measured. The severity of PI was categorized as mild, moderate or severe and compared to the data obtained by CMR. On CMR the mean PRF was 29.2 {+-} 13.4%. Patients with a transannular patch had a significantly higher PRF (39.9 {+-} 11.6%) than patients with an intact annular ring (23.6 {+-} 11.4%). Differentiation by Doppler ECHO between the categories mild, moderate and severe PI was confirmed by significant differences in PRF measured by CMR (mild vs. moderate P < 0.04; moderate vs. severe P < 0.014; mild vs. severe P < 0.001). Furthermore, PRF correlated with right ventricular end diastolic volume index (r = 0.45, P < 0.01) and right ventricular end systolic volume index (r = 0.39, P < 0.01). Doppler ECHO can estimate the severity of PI after repair of TOF with acceptable results compared to CMR flow measurement. In univariate analysis there is only a weak influence of PRF on right ventricular volume. (orig.)

  12. Evaluation of postoperative pulmonary regurgitation after surgical repair of tetralogy of Fallot: comparison between Doppler echocardiography and MR velocity mapping

    International Nuclear Information System (INIS)

    Grothoff, Matthias; Spors, Birgit; Gutberlet, Matthias; Abdul-Khaliq, Hasim

    2008-01-01

    Pulmonary regurgitation is a common finding in patients after correction of tetralogy of Fallot (TOF). Right ventricular impairment and even ventricular arrhythmia have been ascribed to pulmonary valve insufficiency (PI), which is therefore an important issue in follow-up examinations. To compare PI measured by echocardiography (ECHO) with data provided by cardiac MRI (CMR). We studied 54 selected patients (18 female; median age 14.0 years, range 3.8-53.4 years) after surgical correction of TOF. To quantify pulmonary regurgitant fraction (PRF) by CMR, flow velocity mapping was performed. On Doppler ECHO, length, width and localization of regurgitant flow was measured. The severity of PI was categorized as mild, moderate or severe and compared to the data obtained by CMR. On CMR the mean PRF was 29.2 ± 13.4%. Patients with a transannular patch had a significantly higher PRF (39.9 ± 11.6%) than patients with an intact annular ring (23.6 ± 11.4%). Differentiation by Doppler ECHO between the categories mild, moderate and severe PI was confirmed by significant differences in PRF measured by CMR (mild vs. moderate P < 0.04; moderate vs. severe P < 0.014; mild vs. severe P < 0.001). Furthermore, PRF correlated with right ventricular end diastolic volume index (r = 0.45, P < 0.01) and right ventricular end systolic volume index (r = 0.39, P < 0.01). Doppler ECHO can estimate the severity of PI after repair of TOF with acceptable results compared to CMR flow measurement. In univariate analysis there is only a weak influence of PRF on right ventricular volume. (orig.)

  13. The association between brain natriuretic peptide and tissue Doppler parameters in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Taliha Öner

    2016-01-01

    Full Text Available In this study, we investigated the association between brain natriuretic peptide (BNP levels and tissue Doppler imaging measurements and also screening for deadly mutations in patients with hypertrophic cardiomyopathy (HCM. We enrolled 20 patients diagnosed with HCM (age:10.7±5 years (1-17, 85% male, weight:42.25±23.10 kg, height:141.80±32.45 cm and 20 age, gender and body weight-matched control subjects. We performed electrocardiography, transthoracic echocardiography, and tissue Doppler echocardiography in each group, as well as genetic tests (for Arg403Gln, Arg453Cys, Arg719Trp and Arg719Gln mutations in MYH7 Exons 13, 14, 19 and BNP in the patients. The patients were divided into two groups according to the presence (Group 1 or absence (Group 2 of left ventricular (LV outflow tract obstruction. QTc dispersion and the LV ejection fraction and left atrial (LA volume index were increased in Group 1. The LA volume index and the mitral and septal E/Ea ratio and septum Z-score were increased while the mitral lateral annulus and septal annulus Ea wave velocities and the mitral and tricuspid E/A ratio were decreased in patients with high levels of BNP compared to those with normal BNP levels. There were no mutations that are associated with increased risk of sudden death found in patients included in this study. In the light of our data, we conclude that such parameters BNP levels above the 98 pg/mL, septal thickness Z-score ˃6, and higher mitral and septal E/Ea ratios can be used for management of patients with HCM according to life-threatening conditions.

  14. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Pyshnyi, Michael Ph. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation); Kuznetsov, Oleg A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)], E-mail: kuznetsov_oa@yahoo.com; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)

    2009-05-15

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  15. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    International Nuclear Information System (INIS)

    Pyshnyi, Michael Ph.; Kuznetsov, Oleg A.; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A.

    2009-01-01

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  16. Pulsed and Tissue Doppler Echocardiographic Changes in Patients with Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Taysir S. Garadah

    2010-01-01

    Full Text Available Background Doppler echocardiographic studies of left ventricle (LV systolic and diastolic function in patients with β-Thalassemia Major (β-TM had shown different patterns of systolic and diastolic dysfunction. Aim This cross-sectional study was designed to study the LV systolic and diastolic function in patients with β-TM using Pulsed Doppler (PD and Tissue Doppler (TD echocardiography. Methods All patients were evaluated clinically and by echocardiography, The study included patients with β-TM (n = 38, age 15.7 ± 8.9 years compared with an age-matched control group (n = 38, age 15.9 ± 8.9 years. The pulse Doppler indices were normalized for age and heart rate. Results Compared with control patients, M-Mode showed that patients with β-TM have thicker LV septal wall index (0.659 ± 0.23 vs. 0.446 ± 0.219 cm, P ≤ 0.001, posterior wall index (0.659 ± 0.235 vs. 0.437 ± 0.214 cm, P ≤ 0.01, and larger LVEDD index is (3.99 ± 0.48 vs. 2.170 ± 0.57 mm. P = 0.035. Pulsed Doppler showed high LV trans-mitral E wave velocity (70.818 ± 10.139 vs. 57.532 ± 10.139, p = 0.027 and E/A ratio (1.54 vs. 1.23, P ≤ 0.01. The duration of Deceleration time (DT and isovolumic relaxation time (IVRT were significantly shorter in patients with β-TM (150.234 ± 20.0.23 vs. 167.123 ± 19.143 msec, P ≤ 0.01 and (60.647 ± 6.77 vs. 75.474 ± 5.83 msec, P ≤ 0.001, respectively. The ratio of transmitral E wave velocity to the tissue Doppler E wave at the basal septal mitral annulus E/Em – was significantly higher in β-TM group (14.024 ± 2.29 vs. 12.132 ± 1.82, P ≤ 0.01. The Tissue Doppler systolic velocity (Sm and the early diastolic velocity (Em were significantly lower in β-TM group compared to control (4.31 ± 1.2 cm/s vs. 6.95 ± 2.1, P ≤ 0.01 and 4.31 ± 2.7 cm/s vs. 5.82 ± 2.5, P ≤ 0.01 respectively. The tricuspid valve velocity was significantly higher than controls (2.993 ± 0.569 vs. 1.93 ± 0.471 m/sec, respectively, P ≤ 0

  17. Evaluation of left ventricular function in obese children without hypertension by a tissue Doppler imaging study.

    Science.gov (United States)

    Ghandi, Yazdan; Sharifi, Mehrzad; Habibi, Danial; Dorreh, Fatemeh; Hashemi, Mojtaba

    2018-01-01

    The prevalence of obesity is increasing worldwide. Obese children without hypertension are becoming an important health challenge. Complications of obesity in adults are well established, but in obese children, cardiac dysfunction has not been reported clinically. The present crosssectional study investigates subclinical systolic and diastolic dysfunction using echocardiographic modalities. Twentyfive youngsters with body mass index (BMI) >30 and 25 healthy children with BMI <25 were assigned into case and control group, respectively. In all participants, complete cardiovascular examination, electrocardiography, and echocardiography were fulfilled. Echocardiography surveys included standard, pulsed wave Doppler (PWD), and tissue Doppler imaging (TDI). SPSS software, version 24. The two groups were matched for age and sex. The resting heart rate and blood pressure were markedly higher in the obese group ( P = 0.0001) though they were within the normal range in either category. Ejection fraction in the two groups was similar. Left ventricular (LV) mass ( P = 0.0001), LV mass index ( P = 0.029), left atrialtoaortic diameter ratio ( P = 0.0001), and LV enddiastolic diameter ( P = 0.008) were significantly greater in the case group, indicating cardiomegaly and subclinical systolic and diastolic dysfunction. Except for the aortic velocity, all PWD variables were considerably lower in the case group, suggesting subclinical diastolic dysfunction. All TDI parameters varied significantly between the two categories. There was a direct correlation between isovolumetric relaxation time and BMI. Obesity in children without hypertension is associated with subclinical systolic and diastolic cardiac dysfunction. We propose the evaluation of blood pressure as well as myocardial performance using PWD and TDI in all obese children without hypertension, regularly.

  18. Relaxation and filling of the left ventricle assessed by Doppler echocardiography

    International Nuclear Information System (INIS)

    Myreng, Y.

    1990-01-01

    In patients with coronary disease the Doppler method described in the present work was capable of detecting a delayed left ventricular (LV) relaxation and a shift of LV filling from early towards late diastole. This might reflect changes in LV diastolic function due to myocardial ischemia. Furthermore, the method allowed monitoring of changes during treatment with atenolol and verapamil. These changes indicated that atenolol and verapamil were able to partially correct the relaxation abnormailty and increase the relative contribution of early diastolic filling. Although all the numerous variables that influence LV transmitral filling could be controlled in this noninvasive clinical study, the results suggest that antianginal drugs may have beneficial effect on diastolic function in coronary disease. 62 refs., 3 figs., 4 tabs

  19. Value of dobutamine stress tissue Doppler in evaluation of LV ...

    African Journals Online (AJOL)

    Shaimaa Ahmed Mostafa

    2014-12-12

    Dec 12, 2014 ... Prediction of functional recovery, based on the detection of contractile reserve with dobutamine stress echocardiography. (DSE), includes myocardial perfusion imaging, metabolic imaging with conventional scintigraphy and positron emission tomography (PET).12. Dobutamine stress echocardiography is ...

  20. The history of echocardiography.

    Science.gov (United States)

    Edler, Inge; Lindström, Kjell

    2004-12-01

    Following a brief review of the development of medical ultrasonics from the mid-1930s to the mid-1950s, the collaboration between Edler and Hertz that began in Lund in 1953 is described. Using an industrial ultrasonic flaw detector, they obtained time-varying echoes transcutaneously from within the heart. The first clinical applications of M-mode echocardiography were concerned with the assessment of the mitral valve from the shapes of the corresponding waveforms. Subsequently, the various M-mode recordings were related to their anatomical origins. The method then became established as a diagnostic tool and was taken up by investigators outside Lund, initially in China, Germany, Japan and the USA and, subsequently, world-wide. The diffusion of echocardiography into clinical practice depended on the timely commercial availability of suitable equipment. The discovery of contrast echocardiography in the late 1960s further validated the technique and extended the range of applications. Two-dimensional echocardiography was first demonstrated in the late 1950s, with real-time mechanical systems and, in the early 1960s, with intracardiac probes. Transesophageal echocardiography followed, in the late 1960s. Stop-action two-dimensional echocardiography enjoyed a brief vogue in the early 1970s. It was, however, the demonstration by Bom in Rotterdam of real-time two-dimensional echocardiography using a linear transducer array that revolutionized and popularized the subject. Then, the phased array sector scanner, which had been demonstrated in the late 1960s by Somer in Utrecht, was applied to cardiac studies from the mid-1970s onwards. Satomura had demonstrated the use of the ultrasonic Doppler effect to detect tissue motion in Osaka in the mid-1950s and the technique was soon afterwards applied in the heart, often in combination with M-mode recording. The development of the pulsed Doppler method in the late 1960s opened up new opportunities for clinical innovation. The

  1. Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

    Science.gov (United States)

    Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi

    2004-06-01

    Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

  2. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  3. Transcranial Doppler and transesophageal echocardiography: comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection.

    Science.gov (United States)

    Caputi, Luigi; Carriero, Maria Rita; Falcone, Chiara; Parati, Eugenio; Piotti, Patrizia; Materazzo, Carlo; Anzola, Gian Paolo

    2009-01-01

    Patent foramen ovale (PFO) has been investigated in several conditions apart from cryptogenic ischemic stroke. Contrast transesophageal echocardiography (cTEE) is the gold standard for the diagnosis, although it has some known limitations. Contrast transcranial Doppler (cTCD) allows a semiquantitative estimation of right-to-left shunt (RLS) volume. The aims of our study were to confirm the diagnostic accuracy of cTCD in PFO diagnosis and to compare the abilities of cTCD and cTEE to detect a RLS and PFO, respectively, under normal breathing. The latter could represent an important feature for its clinical significance. A total of 100 consecutive patients (59 women and 41 men, age 46 +/- 12 years) were evaluated after stabilized ischemic stroke/transient ischemic attack, migraine, and lacunae, and before neurosurgery in sitting position. All patients undertook cTEE and cTCD, at rest and under Valsalva maneuver (VM). cTEE under VM was the reference standard. A categorization of patients and a semiquantitative cTCD classification were proposed. In all, 63 of 100 patients had PFO diagnosed by cTEE. A general concordance of up to 90% between both techniques was found. cTCD sensitivity and specificity were 96.8% and 78.4%, respectively. In 17 of 100 patients with cTEE-proven PFO under VM, cTCD and cTEE detected RLS at rest in 75% (95% confidence interval [CI] 62%-85%) and 48% (95% CI 35%-61%) of cases, respectively (P < .001). cTEE disclosed RLS at rest in about 71% (95% CI 9%-42%) of cTCDs showing a "shower-curtain" pattern and only in about 22% (95% CI 52%-85%) of those cTCDs without that pattern. In diagnosing PFO, cTCD has a good accuracy compared with cTEE. To detect a RLS at rest, cTCD appears to be more sensitive than cTEE. The latter resulted positive under normal breathing, mostly in cases of significant RLS at cTCD. Our results point out the impact of cTCD in the evaluation of RLS volume, thus aiding, in association with the anatomic details by cTEE, in the

  4. Recent advances in echocardiography for nuclear medicine physician

    International Nuclear Information System (INIS)

    Hong, Geu Ru; Shin, Dong Gu

    2005-01-01

    Echocardiography is one of the most frequently used techniques for diagnosing cardiovascular diseases. Over the last twenty years, technological advances have enabled the application of high-quality imaging. Important recent developments have occurred in echocardiography that are already being used clinically. Equipment and hardware is now available to produce real time three-dimensional and contrast enhanced imaging. Tissue Doppler and stress echocardiography have provided potential benefit to analyze hemodynamic information of heart. This review discusses each of these new developments and their potential impact on the practice of echocardiography and cardiology in general

  5. Hypercholesterolemia and Myocardial function evaluated via Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Kotaru Pavan

    2009-11-01

    Full Text Available Abstract Objective To establish a link between hypercholesterolemia and myocardial dysfunction. Background Heart failure is a complex disease involving changes in systolic and diastolic function. Newer echocardiographic imaging modalities may be able to detect discreet changes in myocardial function associated with hypercholesterolemia. Therefore we sought to establish a link between hypercholesterolemia and myocardial dysfunction with tissue Doppler imaging (TDI. Methods Twenty-seven rabbits were studied: 7 were fed normal chow (group 1 and 20 a high cholesterol diet (10 with ezetimibe, 1 mg/kg/day; group 2 and 10 without, group 3. Echocardiographic images were obtained under general anesthesia. Serum cholesterol levels were obtained at baseline, 3 and 6 months and myocardial cholesterol levels measured following euthanasia. Results Doppler measurements, including E/A, E'/A' and S' were significantly lower in group 3 compared to both groups 1 and 2 but no significant differences were noted in chamber sizes or ejection fraction among the groups. Average serum cholesterol was higher in group 3 compared to groups 1 and 2 respectively (495 ± 305 mg/dl vs. 114 ± 95 mg/dl and 87 ± 37 mg/dl; p 2 = 0.17 p = 0.04, r2 = 0.37 p = 0.001 and r2 = 0.24 p = 0.01. Conclusion Cholesterol load in the serum and myocardium was significantly associated with decreased systolic and diastolic function by TDI. Moreover, lipid lowering was protective.

  6. Application of Echocardiography on Transgenic Mice with Cardiomyopathies

    Directory of Open Access Journals (Sweden)

    G. Chen

    2012-01-01

    Full Text Available Cardiomyopathies are common cardiac disorders that primarily affect cardiac muscle resulting in cardiac dysfunction and heart failure. Transgenic mouse disease models have been developed to investigate the cellular mechanisms underlying heart failure and sudden cardiac death observed in cardiomyopathy cases and to explore the therapeutic outcomes in experimental animals in vivo. Echocardiography is an essential diagnostic tool for accurate and noninvasive assessment of cardiac structure and function in experimental animals. Our laboratory has been among the first to apply high-frequency research echocardiography on transgenic mice with cardiomyopathies. In this work, we have summarized our and other studies on assessment of systolic and diastolic dysfunction using conventional echocardiography, pulsed Doppler, and tissue Doppler imaging in transgenic mice with various cardiomyopathies. Estimation of embryonic mouse hearts has been performed as well using this high-resolution echocardiography. Some technical considerations in mouse echocardiography have also been discussed.

  7. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  8. Assessment of regional systolic and diastolic myocardial function using tissue Doppler and strain imaging in dogs with dilated cardiomyopathy.

    Science.gov (United States)

    Chetboul, Valérie; Gouni, Vassiliki; Sampedrano, Carolina Carlos; Tissier, Renaud; Serres, François; Pouchelon, Jean-Louis

    2007-01-01

    Tissue Doppler Imaging (TDI) or strain (St) imaging could provide sensitive indices for early detection and treatment follow-up of canine dilated cardiomyopathy (DCM). Analysis of TDI and St features in dogs with overt DCM is a prerequisite before using these new criteria in prospective screenings of predisposed families or in clinical trials. Radial and longitudinal right and left myocardial motion, assessed by TDI and St variables, is altered in dogs with DCM. Case records for 26 dogs; 14 with DCM and 12 healthy controls of comparable age and weight were reviewed. A retrospective analysis was conducted of conventional echocardiography, 2-dimensional color TDI, and St imaging data. The DCM group was characterized by decreases in radial and longitudinal systolic velocity gradients of the left ventricular free wall (LVFW), radial and longitudinal absolute values of peak systolic St of the LVFW, and longitudinal systolic right ventricular (RV) velocities (all P canine DCM.

  9. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  10. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  11. Associations between thoracic radiographic changes and severity of pulmonary arterial hypertension diagnosed in 60 dogs via Doppler echocardiography: A retrospective study.

    Science.gov (United States)

    Adams, Dustin S; Marolf, Angela J; Valdés-Martínez, Alejandro; Randall, Elissa K; Bachand, Annette M

    2017-07-01

    Doppler echocardiography is a noninvasive method for estimating and grading pulmonary arterial hypertension. No current literature associates significance of radiographic findings with severity of pulmonary arterial hypertension. We hypothesized that the number and conspicuity of radiographic findings suggestive of pulmonary arterial hypertension would be greater based on the severity of pulmonary arterial hypertension. Dogs with pulmonary arterial hypertension and normal control dogs were included in this retrospective, case control study. Three radiologists blinded to echocardiographic results scored thoracic radiographs for right ventricular and main pulmonary artery enlargement and pulmonary lobar artery enlargement, tortuosity, and blunting by multiple methods. Presence or absence of each finding was scored in an additive fashion and averaged for each grade of pulmonary arterial hypertension severity. Seventy-one dogs (60 dogs with pulmonary arterial hypertension and 11 control dogs) of which some had multiple studies were included: 20 mild, 21 moderate, 25 severe, and 11 absent pulmonary arterial hypertension. The following radiographic findings were significantly associated with increasing pulmonary arterial hypertension severity: right ventricular enlargement by "reverse D" and "3/5-2/5 cardiac ratio" methods, main pulmonary artery enlargement, and caudal lobar artery enlargement by the "3rd rib" method. Mean scores for severe pulmonary arterial hypertension and normal dogs were significantly different (P-value < 0.0001). Mean scores between different pulmonary arterial hypertension grades increased with severity but were not statistically significant. Individually and in combination, radiographic findings performed poorly in differentiating severity of pulmonary arterial hypertension. Findings indicated that thoracic radiographs should be utilized in conjunction with Doppler echocardiography in a complete diagnostic work-up for dogs with suspected

  12. Evaluation of Cardiovascular System in Fibromyalgia Syndrome: Tissue Doppler Echocardiographic Investigation

    Directory of Open Access Journals (Sweden)

    Selma YAZICI

    2010-05-01

    Full Text Available Aim: We aim to investigate besides the cardiac structures and functions by both conventionalmethods and Tissue Doppler Echocardiography (TDE which is a new and useful method inpatients with Fibromyalgia (FM. Additionally, we evaluated QT parameters (QT maximum,QT minimum and QT dispertion with the use of electrocardiography in order to measure theautonomic dysfunction which is a possible mechanism in the pathogenesis of the disease. Methods: The study was performed on 42 patients (mean age 41 years, 38 female and 38completely healthy subjects (35 female, mean age of 42 years who were admitted to the sameclinic were collected as the control group. All the individuals were undergone a completephysical examination, electrocardiography (recordings were displayed at 50 mm/s speed andechocardiography evaluation (both conventional methods and TDE.Results: Analysis of electrocardiographic recordings revealed mildly increased mean QTdispertion in the patient group, but this difference was statistically insignificant. Analysis ofconventional echocardiographic parameters revealed similar results between the patient groupand the control cases. However, an important finding of this study is that significant diastolicdysfunction was found in the patient group which was recorded with the TDE technique. Emwave velocity and Em/Am ratios were significantly lower in patients with FM compared withcontrols (p<0.005, p<0.01, respectively. Sm and Am waves velocities were similar in bothgroups. Conclusion: In this study, significant left ventricular diastolic dysfunction which was detectedby TDE technique can partly explain several symptoms such as fatigue and dyspnea in FM. Inaddition, fully cardiac evaluation of patients with FM might be obtained supporting findingsthe autonomic dysfunction theory in fibromyalgia pathogenesis.

  13. Detection of Early Right Ventricular Dysfunction in Young Patients With Thalassemia Major Using Tissue Doppler Imaging

    Science.gov (United States)

    Bornaun, Helen; Dedeoglu, Reyhan; Oztarhan, Kazim; Dedeoglu, Savas; Erfidan, Erkan; Gundogdu, Muge; Aydogan, Gonul; Cengiz, Dicle

    2016-01-01

    Background Myocardial iron overload is the most common cause of mortality in patients with thalassemia major (TM), also known as beta-thalassemia. T2* cardiovascular magnetic resonance imaging (MRI) is the best way of monitoring cardiac iron, and new echocardiographic techniques can be used to assess cardiac function. Objectives The aim of this study was to assess the systolic and diastolic right ventricular (RV) function of patients with TM using tissue Doppler imaging (TDI) and to determine whether this echocardiographic technique is an adequate diagnostic tool for the screening and detection of subclinical cardiac dysfunction. Patients and Methods Eighty-four patients with TM were evaluated by conventional echocardiography and pulse-wave TDI. The data of the TM group (Group 1) were compared with that of 85 age- and sex-matched healthy controls (Group 2). Cardiovascular T2* MRI examinations were performed in 49 of the 85 patients. Results The patients with TM had significantly lower values for weight, height, body mass index, systolic arterial pressure, deceleration time, E’/A’, and ejection time (ET) than the controls. Group 1 also had significantly higher values for peak early diastolic velocity (E) over peak late diastolic velocity (A), peak early diastolic velocity of TDI (E’), peak late diastolic velocity of TDI (A’), E/E’, isovolumetric relaxation time, isovolumetric contraction time, and RV magnetic perfusion imaging (MPI) than Group 2. Conclusions RV diastolic dysfunction occurs before systolic deterioration in patients with TM and cannot be screened with conventional echocardiographic techniques. In routine practice, TDI measurements, MPI (for global function) and the E/E’ parameter (for diastolic function) can be used to screen and detect early RV dysfunction. PMID:27617076

  14. Performance of two-dimensional Doppler echocardiography for the assessment of infarct size and left ventricular function in rats

    Directory of Open Access Journals (Sweden)

    Nozawa E.

    2006-01-01

    Full Text Available Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes, infarct size (percentage of the arc with infarct on 3 transverse planes, systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient. Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005. The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction to 53.1 ± 1.5% (control and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001 and histology (r = -0.78; P < 00001. The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7 was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3. There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

  15. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  16. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  17. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  18. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  19. Subclinical myocardial dysfunction by tissue Doppler echocardiography in primary antiphospholipid syndrome: Preliminary results

    Directory of Open Access Journals (Sweden)

    Tarcila Fontes de Lima Gomes Lucena

    2018-01-01

    Conclusion: The present study demonstrated subclinical myocardial dysfunction using TDI in asymptomatic PAPS patients. TDI is non-invasive and cost effective. Prospective studies including a large number of participants in order to confirm these preliminary data are needed.

  20. Tissue Doppler echocardiography predicts acute myocardial infarction, heart failure, and cardiovascular death in the general population

    DEFF Research Database (Denmark)

    Mogelvang, Rasmus; Biering-Sørensen, Tor; Jensen, Jan Skov

    2015-01-01

    echocardiographic measures. Combining information on early and late diastolic function by TDI provided incremental prognostic information and improved risk classification (net reclassification improvement: 27%; P

  1. Myocardial function in long distance runners: Assessment by echocardiography, tissue Doppler and speckle tracking

    OpenAIRE

    Pons, Jaume; Forteza, Josep Francesc; Riverso, Daniel; Aceña, Marta; Rodriguez, Antonio; Gómez, Alfredo; Fernández-Palomeque, Carlos; Bethencourt, Armando

    2014-01-01

    Introducción y objetivos: El ejercicio físico provoca respuestas adaptativas y cambios morfológico-funcionales en el corazón del atleta. El objetivo del presente estudio es caracterizar dichos cambios mediante ecocardiografía convencional y las nuevas técnicas de deformación miocárdica mediante speckle tracking. Material y métodos: Se estudiaron prospectivamente a 68 varones, 38 corredores de fondo (42±8 años), y 30 controles (40±7 años). Se les realizó estudio ecocardiográfico convencional m...

  2. Diastolic left ventricular function in preterm infants with a patent ductus arteriosus: a serial Doppler echocardiography study.

    Science.gov (United States)

    Schmitz, Lothar; Stiller, Brigitte; Koch, Heike; Koehne, Petra; Lange, Peter

    2004-02-01

    In very low birth weight neonates, a left-to-right shunt via persistent ductus arteriosus (PDA) may interact with diastolic left ventricular function, but specific changes of Doppler parameters have yet to be reported. In a serial transmitral Doppler study, we investigated the impact of a PDA on diastolic function parameters. Twenty-two patients with and without PDA were examined on day 3.8+/-1 and day 14+/-2 after birth. By the first examination, 13 out of 22 patients had a PDA; by the second examination, the number was still 8 out of 22. Peak early and atrial flow velocities (44.8+/-15 and 50.1+/-13 cm/s, respectively) were higher (pclosure of the PDA. When premature infants with a PDA experience a preload challenge, early and atrial peak velocities increase and IVRT shortens significantly. This coincidence of elevated transvalvular pressure differences and decreased IVRT in neonates with immature diastolic function can best be explained as a result of left atrial pressure elevation. Consequently, pulmonary venous pressure must be elevated, with its inherent effect on pulmonary capillary physiology. Thus, the monitoring of left ventricular diastolic function adds significant information to the care of preterm infants with a PDA.

  3. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  4. Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: new insight into the mechanism of atrioventricular valve closure.

    Science.gov (United States)

    Schnittger, I; Appleton, C P; Hatle, L K; Popp, R L

    1988-01-01

    The purpose of this study was to prospectively determine the incidence of diastolic mitral and tricuspid regurgitation in atrioventricular (AV) block using Doppler echocardiography. The temporal relation between mitral and tricuspid diastolic insufficiency and the diastolic murmur recorded in patients with complete heart block was also investigated. Twenty-two consecutive patients with AV block (referred to the Echo-Doppler laboratory for routine clinical studies), aged 18 to 87 years, were enrolled in the study. Eleven patients had third degree AV block and a ventricular-inhibited (VVI) pacemaker, two patients had second degree AV block, seven patients had first degree AV block, one patient had blocked premature atrial complexes and one patient had atrial flutter with 4:1 AV block. Diastolic mitral regurgitation was detected in 20 patients, and diastolic tricuspid regurgitation in 21. A mid-diastolic murmur was detected in all patients except in the three youngest. The murmur occurred before diastolic regurgitation and coincided with peak forward flow through the AV valve after atrial contraction. M-mode mitral valve echocardiograms obtained in nine patients demonstrated near closure of some portions of the mitral valve after atrial contraction. Effective closure of the valve, however, did not occur unless ventricular systole supervened. In conclusion, diastolic mitral and tricuspid regurgitation are almost universally present in patients with AV block and are associated with a diastolic murmur. The murmur coincides with forward AV valve flow. Diastolic regurgitation is silent. Effective AV valve closure is not established until ventricular systole occurs, as demonstrated by M-mode echocardiographic recording of the mitral valve.

  5. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  6. Clinical and Echocardiographic Evaluation of Regional Systolic Function Detected by Tissue Doppler Imaging in Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    A Sadeghpour

    2009-09-01

    Full Text Available Background: Hypertrophic cardiomyopathy (HCM is the most common type of the genetic cardiovasculardiseases. Regarding to tremendous heterogeneity in the phenotypic expression of HCM, which is generally unrelatedto genotype, we aimed to study, clinical and echocardiographic parameters such as Tissue Doppler Imaging(TDI in various subtypes of HCM patients and evaluate the influence of race and gender in Iranian patients.Methods: Patients with HCM underwent a complete clinical and echocardiographic study including TDI toassess regional systolic contraction( in the 12 segments and early diastolic annular velocity (Em from theseptal mitral annulus.Results: The study comprised 41 patients (20 women, mean age = 41 ± 15 years with mean LVEF 55%±4.8%and mean maximal septal thickness 2.07cm. Considering LVOT gradient>30mmHg, hypertrophic obstructivecardiomyopathy (HOCM was found in 18 (45%. Asymmetric septal hypertrophy (ASH existed in 27 patients(67%, systolic anterior motion of anterior mitral leaflet (SAM in 25 persons (64%. Nineteen patients (46.3%were included in NYHA function class (FC II and 6 (14.7% in FC III or higher. We found syncope in 10(24.4%, chest pain in 4 (9.8%, atrial fibrilation in 14.6 % and ventricular arrhythmias in (17.1% of patients.History of ICD was seen in 7 (17.1% and PPM in 9 cases. Mean E’ velocity was 5.44± 1.65 cm/sec and S velocity5.70± 1.49 cm/sec with significant lower S velocity and E’ in syncope patients. Overall, HOCM patients hadgrade II diastolic dysfunction with E/É >15(17.54±7.46. Majority (25 of cases (61% were categorized in typeIII of HCM. RV involvement was observed in 11 patients (28.2%.No significant differences existed betweenprevalence of syncope and dysrhythmia among HCM and HOCM patients.Conclusion: In our study, we found lower detection of latent HOCM, compared to other studies, suggestive ofinadequate use of appropriate provocative maneuvers such as exercise stress echocardiography and amyl

  7. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    OpenAIRE

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 ...

  8. Myocardial left ventricular dysfunction in patients with systemic lupus erythematosus: new insights from tissue Doppler and strain imaging.

    Science.gov (United States)

    Buss, Sebastian J; Wolf, David; Korosoglou, Grigorios; Max, Regina; Weiss, Celine S; Fischer, Christian; Schellberg, Dieter; Zugck, Christian; Kuecherer, Helmut F; Lorenz, Hanns-Martin; Katus, Hugo A; Hardt, Stefan E; Hansen, Alexander

    2010-01-01

    Systemic lupus erythematosus (SLE) is associated with high cardiovascular morbidity and mortality. Cardiovascular involvement is frequently underestimated by routine imaging techniques. Our aim was to determine if new echocardiographic imaging modalities like tissue Doppler (TDI), strain rate (SRR), and strain (SRI) imaging detect abnormalities in left ventricular (LV) function in asymptomatic patients with SLE. Sixty-seven young patients with SLE (mean age 42 +/- 10 yrs) without typical symptoms or signs of heart failure or angina, and a matched healthy control group (n = 40), underwent standard transthoracic echocardiography, TDI, SRR, and SRI imaging of the LV as well as assessment of disease characteristics. Despite findings within the normal range on routine standard 2-dimensional echocardiography, SLE was associated with significantly impaired systolic and diastolic myocardial velocities of the LV measured by TDI [mean global TDI: systolic (s): 2.9 +/- 0.9 vs 3.9 +/- 0.7 cm/s, p < 0.05; early (e): 4.3 +/- 1.5 vs 6.3 +/- 1.3 cm/s, p < 0.05; late (a): 2.9 +/- 0.8 vs 3.4 +/- 0.8 cm/s, p < 0.05; values +/- SD); SRR (s: -0.8 +/- 0.1 vs -1.1 +/- 0.1 s(-1); e: 1.1 +/- 0.2 vs 1.6 +/- 0.3 s(-1); a: 0.7 +/- 0.1 vs 1.0 +/- 0.2 s(-1); all p < 0.05); and SR (-15.11 +/- 2.2% vs -19.7 +/- 1.9%; p < 0.05) compared to the control group. Further, elevated disease activity, measured with the ECLAM and the SLEDAI score, resulted in significantly lower values for LV longitudinal function measured by SRR and SR, but not by TDI. SLE is associated with a significant impairment of systolic and diastolic LV longitudinal function in patients without cardiac symptoms. New imaging modalities provide earlier insight into cardiovascular involvement in SLE and seem to be superior to standard echocardiography to detect subclinical myocardial disease.

  9. Indicaciones básicas para la realización de ecocardiografía-Doppler-color Basic indications for the performance of color Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Fernando Manzur

    2005-06-01

    physiopathology give sufficient bases for the clinical decision assessment and emphasizes the evidence’s examination for the clinical investigation. The comprehension of certain evidence rules is necessary for the correct interpretation of literature in respect to the causes, diagnostic tools and treatment strategies. The main aim of this research is to make a protocol for the indications of an echocardiogram in the clinical practice and to educate our country’s general physicians in this conduct. The good practice is due to initiatives, activities and functional models that are in progress worldwide, as confirmed by evidence. Objective: echocardiography is actually the gold standard for the study of heart anatomy and physiology. Since its introduction in the clinical practice more than three decades ago, it has had such diffusion that it is considered an important tool in the cardiology assistance. It provides trustworthy functional anatomic information, as well as diagnosis and is decisive in the treatment and resolution of cardiovascular diseases. The progressive development of this technique has enabled its use in all the different fields that may affect the cardiovascular system. The objective is to help the clinical physicians in the making of decisions in concrete situations, guaranteeing them that the diagnosis is based on results given by valid scientific studies. In accordance to this, different studies as well as task force and management guides representative of the worldwide literature, were compiled.

  10. TISSUE DOPPLER IMAGING OF LONGITUDINAL MOVEMENT OF A FIBROUS RING OF MITRAL VALVE DURING ISOVOLUMIC PERIODS IN LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    B. Amarjagal

    2007-01-01

    Full Text Available Aim. To study change of rate and duration indicators of longitudinal movement of a fibrous ring of mitral valve (MFR during isovolumic contraction (IVC and relaxation (IVR in hypertensive patients with various degree of a left ventricular hypertrophy (LVH.Material and methods. 80 hypertensive patients with moderate LVH (n=40 and severe LVH (n=40 are examined. The control group was presented by 30 healthy volunteers. Transthoracic echocardiography and Tissue Doppler imaging has been performed with ultrasonic tomograph “HDI 5000” (Philips.Results. Increase in LVH (Smm and Е/Еmm associates with reduction in systolic velocity of movement of medial MFR (Smm. There is direct relation with duration of IVC-negative and IVR-positive components and myocardium mass index. Maximal velocity of IVC-positive component increases and maximal velocity of IVR-negative component decreases when LVH is growing.Conclusion. Velocities curves of IVC and IVR were bi-phase both in healthy persons and in hypertensive patients with LVH. Velocity and duration of positive and negative components of IVC and IVR depended on LVH degree.

  11. TISSUE DOPPLER IMAGING OF LONGITUDINAL MOVEMENT OF A FIBROUS RING OF MITRAL VALVE DURING ISOVOLUMIC PERIODS IN LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    B. Amarjagal

    2015-12-01

    Full Text Available Aim. To study change of rate and duration indicators of longitudinal movement of a fibrous ring of mitral valve (MFR during isovolumic contraction (IVC and relaxation (IVR in hypertensive patients with various degree of a left ventricular hypertrophy (LVH.Material and methods. 80 hypertensive patients with moderate LVH (n=40 and severe LVH (n=40 are examined. The control group was presented by 30 healthy volunteers. Transthoracic echocardiography and Tissue Doppler imaging has been performed with ultrasonic tomograph “HDI 5000” (Philips.Results. Increase in LVH (Smm and Е/Еmm associates with reduction in systolic velocity of movement of medial MFR (Smm. There is direct relation with duration of IVC-negative and IVR-positive components and myocardium mass index. Maximal velocity of IVC-positive component increases and maximal velocity of IVR-negative component decreases when LVH is growing.Conclusion. Velocities curves of IVC and IVR were bi-phase both in healthy persons and in hypertensive patients with LVH. Velocity and duration of positive and negative components of IVC and IVR depended on LVH degree.

  12. Systolic and Diastolic Function by Tissue Doppler Imaging Predicts Mortality in Patients with Atrial Fibrillation

    DEFF Research Database (Denmark)

    Dons, Maria; BieringSørensen, Tor; Jensen, Jan Skov

    2015-01-01

    AIM: Tissue Doppler Imaging (TDI) detects early signs of left ventricular dysfunction. The prognostic potential of TDI in patients with atrial fibrillation (AF) has, however, not yet been clarified. This study evaluates the prognostic value of TDI in patients with atrial fibrillation. METHODS...

  13. Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sørensen, Tor; Søgaard, Peter

    2016-01-01

    BACKGROUND: The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement...

  14. Screening of Chronic Obstructive Pulmonary Disease Patients for Pulmonary Arterial Hypertension Using Two-Dimensional Transthoracic Doppler Echocardiography in Tertiary Care Hospital in India

    Directory of Open Access Journals (Sweden)

    Vinay Mahishale

    2015-01-01

    Full Text Available Background: Chronic obstructive pulmonary disease (COPD and pulmonary arterial hypertension (PAH are common and underdiagnosed medical conditions in India. Prevalence of these chronic diseases is high both in rural and urban areas. However, the exact prevalence of PAH in Indian COPD patients is unclear. Comorbid conditions like PAH have a great impact on the outcome of COPD in the form of severity, exacerbations, morbidity, and mortality. Right heart catheterization remains the gold standard test for diagnosis of PAH, but it is invasive and practically not feasible. Aims and objectives: The present study objective was to screen COPD patients for PAH using two-dimensional transthoracic Doppler echocardiography (ECHO in Tertiary Care Hospital. Results: A total of 2040 patients with a confirmed diagnosis of COPD were enrolled in the study. Among these patients, 1509 were males (73.9%, 531 were females (23.06%, and 1428 were known or ex-smokers (70%. None of the females were smokers, but there was a history of biomass fuel exposure for >10 years. As per global initiative for chronic obstructive lung disease criteria, mild, moderate, severe, and very severe COPD was noted in 525,629,511, and 375 patients, respectively. When they were screened using ECHO, prevalence of PAH was 41.96% as 856 subjects had PAH. Prevalence of PAH among mild, moderate, severe, and very severe COPD was 23.8%, 34.81%, 48.53%, and 70.4%, respectively. There was a linear relationship between PAH and severity of COPD. Conclusion: PAH is very common in COPD patients in India. As the severity of COPD increased, the frequency and degree of PAH also increased. ECHO is an excellent tool for detection of PAH in COPD patients. All patients with severe to very severe COPD should be routinely screened by ECHO for PAH and with mild to moderate COPD, who have dyspnea out of proportion to their clinical condition should also be screened for PAH.

  15. Tissue Doppler Imaging in the evaluation of abdominal aortic pulsatility: a useful tool for the neonatologist.

    Science.gov (United States)

    Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo

    2017-03-01

    Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.

  16. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  17. Tissue Doppler Imaging Combined with Advanced 12-Lead ECG Analysis Might Improve Early Diagnosis of Hypertrophic Cardiomyopathy in Childhood

    Science.gov (United States)

    Femlund, E.; Schlegel, T.; Liuba, P.

    2011-01-01

    Optimization of early diagnosis of childhood hypertrophic cardiomyopathy (HCM) is essential in lowering the risk of HCM complications. Standard echocardiography (ECHO) has shown to be less sensitive in this regard. In this study, we sought to assess whether spatial QRS-T angle deviation, which has shown to predict HCM in adults with high sensitivity, and myocardial Tissue Doppler Imaging (TDI) could be additional tools in early diagnosis of HCM in childhood. Methods: Children and adolescents with familial HCM (n=10, median age 16, range 5-27 years), and without obvious hypertrophy but with heredity for HCM (n=12, median age 16, range 4-25 years, HCM or sudden death with autopsy-verified HCM in greater than or equal to 1 first-degree relative, HCM-risk) were additionally investigated with TDI and advanced 12-lead ECG analysis using Cardiax(Registered trademark) (IMED Co Ltd, Budapest, Hungary and Houston). Spatial QRS-T angle (SA) was derived from Kors regression-related transformation. Healthy age-matched controls (n=21) were also studied. All participants underwent thorough clinical examination. Results: Spatial QRS-T angle (Figure/ Panel A) and septal E/Ea ratio (Figure/Panel B) were most increased in HCM group as compared to the HCM-risk and control groups (p less than 0.05). Of note, these 2 variables showed a trend toward higher levels in HCM-risk group than in control group (p=0.05 for E/Ea and 0.06 for QRS/T by ANOVA). In a logistic regression model, increased SA and septal E/Ea ratio appeared to significantly predict both the disease (Chi-square in HCM group: 9 and 5, respectively, p less than 0.05 for both) and the risk for HCM (Chi-square in HCM-risk group: 5 and 4 respectively, p less than 0.05 for both), with further increased predictability level when these 2 variables were combined (Chi-square 10 in HCM group, and 7 in HCM-risk group, p less than 0.01 for both). Conclusions: In this small material, Tissue Doppler Imaging and spatial mean QRS-T angle

  18. Correlation between the tissue Doppler, strain rate, strain imaging during the dobutamine infusion and coronary fractional flow reserve during catheterization: a comparative study.

    Science.gov (United States)

    Dagdelen, Sinan; Yuce, Murat; Emiroglu, Yunus; Ergelen, Mehmet; Pala, Selcuk; Tanalp, Ali Cevat; Izgi, Akin; Kirma, Cevat

    2005-06-22

    Coronary fractional flow reserve (FFR) as an invasive, and dobutamine stress echocardiography (DSE) as a noninvasive technique were used to detect critical coronary stenosis. This study was undertaken to assess correlation between these two techniques by using tissue Doppler, strain rate (SR), and strain imaging (S). In 17 patients (aged 54.9+/-12.6, 4 F), a total of 22 vessels were studied. On dobutamine stress echocardiography, baseline and peak systolic (Sm), early (Em) and late (Am) diastolic myocardial velocities, SR and S were recorded from parasternal view (mid-posterior segment) for radial and apical view (mid-septum) for longitudinal deformation. Then coronary FFR was performed by using intracoronary adenosine infusion, and the value of system were analyzed for longitudinal SR and S values, it had a mild correlation with SR (r = 0.47, p = 0.044) and a good correlation with S (r = 0.66, p = 0.002). The quantification of regional myocardial deformation by using DSE rather than the motion would be more appropriate in detecting the ischemic dysfunctional segment supplied by the critical coronary stenosis. Strain measurement during the dobutamine infusion may provide an information on the FFR results of the culprit vessel.

  19. The use of echocardiography in Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Cai, Qiangjun; Shuraih, Mossaab; Nagueh, Sherif F

    2012-04-01

    Endocardial mapping and radiofrequency catheter ablation are well established modalities for the diagnosis and treatment of patients with Wolff-Parkinson-White (WPW) syndrome associated with tachyarrhythmias. However, the electrophysiologic techniques are invasive, require radiation exposure, and lack spatial resolution of cardiac structures. A variety of echocardiographic techniques have been investigated as a non-invasive alternative for accessory pathway localization. Conventional M-mode echocardiography can detect the fine premature wall motion abnormalities associated with WPW syndrome. However, it is unable to identify the exact site of accessory pathway with sufficient accuracy. 2D, 2D-guided M-mode, and 2D phase analysis techniques are limited by image quality and endocardial border definition. Various modalities of tissue Doppler echocardiography significantly increase the accuracy of left-sided accessory pathway localization to 80-90% even in patients with poor acoustic window. However, right-sided pathways remain a diagnostic challenge. Strain echocardiography by speckle tracking has recently been evaluated and appears promising. Different cardiac abnormalities have been detected by echocardiography in WPW patients. Patients with WPW syndrome and tachyarrhythmias have impaired systolic and diastolic function which improves after radiofrequency ablation. Echocardiography is useful in identifying patient with accessory pathway-associated left ventricular dyssynchrony and dysfunction who may benefit from ablation therapy. Transesophageal and intracardiac echocardiography have been used to guide ablation procedure. Ablation-related complications detected by routine echocardiography are infrequent, rarely clinically relevant, and of limited value.

  20. Systolic pulmonary artery pressure assessed during routine exercise Doppler echocardiography: insights of a real-world setting in patients with elevated pulmonary pressures.

    Science.gov (United States)

    Korff, Susanne; Enders-Gier, Patricia; Uhlmann, Lorenz; Aurich, Matthias; Greiner, Sebastian; Hirschberg, Kristof; Katus, Hugo A; Mereles, Derliz

    2018-03-19

    Pulmonary hypertension is a marker of disease severity. Exercise Doppler echocardiography (EDE) has proven to be feasible and reliable to assess pulmonary pressure. Increase in systolic pulmonary artery pressure (sPAP) has diagnostic and prognostic value in controlled studies. However, its value when assessed during routine examination in patients with cardiopulmonary diseases and resting sPAP > 35 mmHg is not clearly defined. Clinical documentation and offline reevaluation of digitally stored EDE examinations of patients with appropriate clinical indications for EDE were analyzed. N = 278 patients with sPAP at rest > 35 mmHg met inclusion criteria. One patient was lost to follow-up. Mean age of patients was 72 ± 10 years, 178 (64%) of the study population were men. There were no relevant differences among survivors and non-survivors concerning comorbidities. Exercise performance (3.6 ± 1.2 vs. 4.9 ± 1.4 MET, p  45 mm (HR = 2.58, p  42 mmHg (HR = 1.94, p = 0.010) and ΔsPAP increase ≥ 0.23 mmHg/Watt (HF = 1.92, p = 0.010). After multivariate analysis, NYHA functional class III (HR = 2.35, p < 0.001), LA diameter (HR = 2.28, p = 0.003) and sPAP increase ≥ 0.23 mmHg/Watt (HF = 2.19, p = 0.002) remained significant predictors of mortality, whereas a double product (HR = 0.42, p = 0.005) was associated with better prognosis. sPAP assessment during routine EDE provides relevant prognostic information comparable to findings in studies in selected populations. A higher sPAP increase at lower exercise performance shows significant association with increased of mortality.

  1. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  2. Evaluation of Pulsed Doppler-Versus Tissue Doppler-Derived Tei Index of Right and Left Ventricle in Fetuses

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2011-12-01

    Full Text Available Background: The myocardial performance index (MPI, also known as the Tei index, was introduced by Tei et al. to evaluate cardiac function in adults with dilated cardiomyopathy. This index is defined as the sum of isovolumic contraction time (ICT and isovolumic relaxation time (IRT, divided by ejection time (ET. Objectives: To determine the correlation between pulsed Doppler (PD- and tissue Doppler imaging (TDI-derived Tei indices in fetuses. Patients and Methods: Right and left ventricle PD and TDI echocardiographic data were obtained from 59 fetuses (11 pregnant women who were positive for anti-SSA-Ro or anti-SSB-La antibodies, 18 women who were referred due to dysrhythmia, and 30 women who had normal clinical findings. Results: Mean fetal gestational age was 27 ± 6.4 weeks. Mean PD Tei index of the mitral and tricuspid valve was 0.58 ± 0.05 and 0.53 ± 0.08, respectively. Mean TDI indices for the mitral and tricuspid valve were 0.56 ± 0.09 and 0.55 ± 0.08, respectively. There were no significant differences between mitral and tricuspid PD- and TDI-derived Tei indices (P = 0.87, P= 0.21, but the Bland-Altman diagrams showed no fine agreement between the indices (the mean difference ± 1 standard deviation of the right ventricular PD- and TDI-derived Tei indices was 0.24 ± 0.02 and 0.29 ± 0.04 for the left ventricle. There were no significant differences in PD- and TDI-derived Tei indexes between groups of evaluated fetuses (Mitral valve: PD-Tei P=0.69, TDI-Tei P=0.49; Tricuspid valve: PD-Tei P=0.41, TDI-Tei P=0.36. Conclusions: Although the mean values of the two indices did not differ significantly, the TDI-derived and PD-derived Tei indices did not have fine agreement.

  3. Fetal echocardiography

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007340.htm Fetal echocardiography To use the sharing features on this page, please enable JavaScript. Fetal echocardiography is a test that uses sound waves ( ultrasound ) ...

  4. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    2016-01-01

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  5. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  6. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Ruefenacht, D; Delpy, D T

    2006-01-01

    Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware

  7. Prognostic value of systolic mitral annular velocity measured with Doppler tissue imaging in patients with chronic heart failure caused by left ventricular systolic dysfunction

    Science.gov (United States)

    Nikitin, N P; Loh, P H; de Silva, R; Ghosh, J; Khaleva, O Y; Goode, K; Rigby, A S; Alamgir, F; Clark, A L; Cleland, J G F

    2006-01-01

    Objective To assess the prognostic value of various conventional and novel echocardiographic indices in patients with chronic heart failure (CHF) caused by left ventricular (LV) systolic dysfunction. Methods 185 patients with a mean (SD) age of 67 (11) years with CHF and LV ejection fraction < 45% despite optimal pharmacological treatment were prospectively enrolled. The patients underwent two dimensional echocardiography with tissue harmonic imaging to assess global LV systolic function and obtain volumetric data. Transmitral flow was assessed with conventional pulse wave Doppler. Systolic (Sm), early, and late diastolic mitral annular velocities were measured with the use of colour coded Doppler tissue imaging. Results During a median follow up of 32 months (range 24–38 months in survivors), 34 patients died and one underwent heart transplantation. Sm velocity (hazard ratio (HR) 0.648, 95% confidence interval (CI) 0.463 to 0.907, p  =  0.011), diastolic arterial pressure (HR 0.965, 95% CI 0.938 to 0.993, p  =  0.015), serum creatinine (HR 1.006, 95% CI 1.001 to 1.011, p  =  0.023), LV ejection fraction (HR 0.945, 95% CI 0.899 to 0.992, p  =  0.024), age (HR 1.035, 95% CI 1.000 to 1.071, p  =  0.052), LV end systolic volume index (HR 1.009, 95% CI 0.999 to 1.019, p  =  0.067), and restrictive pattern of transmitral flow (HR 0.543, 95% CI 0.278 to 1.061, p  =  0.074) predicted the outcome of death or transplantation on univariate analysis. On multivariate analysis, only Sm velocity (HR 0.648, 95% CI 0.460 to 0.912, p  =  0.013) and diastolic arterial pressure (HR 0.966, 95% CI 0.938 to 0.994, p  =  0.016) emerged as independent predictors of outcome. Conclusions In patients with CHF and LV systolic dysfunction despite optimal pharmacological treatment, the strongest independent echocardiographic predictor of prognosis was Sm velocity measured with quantitative colour coded Doppler tissue

  8. The value of echocardiography in follow-up of human tissue valves in aortic position

    NARCIS (Netherlands)

    T.P. Willems (Tineke)

    1999-01-01

    textabstractThe application of human tissue valves for aortic valve or root replacement was introduced during the 19608. The first successful clinical orthotopic implantation of an aortic allograft was performed by Ross and Barrat-Boyes independently in 19621,2, In 1967 Ross first reported the use

  9. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  10. Early myocardial impairment in type 1 diabetes patients without known heart disease assessed with tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Jensen, Magnus Thorsten; Søgaard, Peter; Andersen, Henrik Ullits

    2016-01-01

    PURPOSE: Cardiovascular disease is the most common cause of mortality in type 1 diabetes; patients with albuminuria are at greatest risk. We investigated myocardial function and premature myocardial impairment in type 1 diabetes patients with and without albuminuria compared to controls. METHODS:...

  11. Impacts of acute severe pulmonary regurgitation on right ventricular geometry and contractility assessed by tissue-Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; K. Iversen, Kasper; G Vejlstrup, Niels

    2010-01-01

    AIMS: Little is known of the impact of acute right ventricular (RV) volume overload on RV function. We assessed the impact of acute severe pulmonary regurgitation (PR) on global and regional RV function by applying novel quantitative echocardiographic markers of myocardial performance in an animal...

  12. Cardiac time intervals and the association with 2D-speckle-tracking, tissue Doppler and conventional echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Jensen, Jan Skov; Andersen, Henrik Ullits

    2016-01-01

    Cardiac time intervals (CTI) are prognostic above and beyond conventional echocardiographic measures. The explanation may be that CTI contain information about both systolic and diastolic measures; this is, however, unknown. The relationship between the CTI and systolic and diastolic function...

  13. Impacts of acute severe pulmonary regurgitation on right ventricular geometry and contractility assessed by tissue-Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Little is known of the impact of acute right ventricular (RV) volume overload on RV function. We assessed the impact of acute severe pulmonary regurgitation (PR) on global and regional RV function by applying novel quantitative echocardiographic markers of myocardial performance in an animal model....

  14. Noninvasive Doppler tissue measurement of pulmonary artery compliance in children with pulmonary hypertension.

    Science.gov (United States)

    Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin

    2006-04-01

    We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Dynamic compliance (C(dyn)) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C(dyn) was calculated as: [(D(s) - D(d))/(D(d) x P(s))] x 10(4); where D(s) = systolic diameter, D(d) = diastolic diameter, and P(s) = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. C(dyn) was also measured in an additional 13 patients undergoing reactivity studies. Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C(dyn) calculated by CMM DTI agreed with C(dyn) calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C(dyn) values than control subjects (P < .01). C(dyn) values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C(dyn) agreed with reactivity measured using impedance techniques. The C(dyn) method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.

  15. Measurement of subcutaneous adipose tissue blood flow in the morbidly obese using a laser Doppler velocimeter

    Science.gov (United States)

    Klassen, Gerald A.; Paton, Barry E.; Maksym, Geoff; Janigan, David; Perey, Bernard

    1992-08-01

    Using a laser Doppler velocimeter (LDV) subcutaneous adipose tissue blood flow (AF) was recorded in the upright and supine positions in the upper and lower abdomen in 22 morbidly obese patients before gastroplasty. Age was 42 +/- 3 (mean +/- SEM), weight 135 +/- 7 kg, and body mass index (BMI) 51 +/- 3. Adipose flow expressed as mV was: supine, upper abdomen 647 +/- 23, lower abdomen 604 +/- 24; upright, upper abdomen 621 +/- 27, lower abdomen 607 +/- 29. AF was significantly more in the upper than lower abdomen (supine position) and AF was significantly lower in the lower abdomen upright than the upper abdomen supine. Regression analysis of age indicates that blood flow decreases in the lower abdomen so that in the supine position the difference between upper and lower abdomen AF increases. Similar analysis of BMI did not indicate significant trends. These data indicate that with morbid obesity there is lower tissue blood flow to the lower abdomen. This may explain why such patients may develop areas of painful ischemic necrosis in the dependent region of their anterior abdominal pannus.

  16. A comparison of left ventricular mass between two-dimensional echocardiography, using fundamental and tissue harmonic imaging, and cardiac MRI in patients with hypertension

    International Nuclear Information System (INIS)

    Alfakih, Khaled; Bloomer, Tim; Bainbridge, Samantha; Bainbridge, Gavin; Ridgway, John; Williams, Gordon; Sivananthan, Mohan

    2004-01-01

    Purpose: To compare left ventricular mass (LVM) as measured by two-dimensional (2D) echocardiography using two different calculation methods: truncated ellipse (TE) and area length (AL), in both fundamental and tissue harmonic imaging frequencies, to LVM as measured by, the current gold standard, cardiac magnetic resonance imaging (MRI). Turbo gradient echo (TGE) pulse sequence was utilized for MRI. Materials and methods: Thirty-two subjects with history of hypertension were recruited. The images were acquired, contours were traced and the LVM was calculated for all four different echocardiography methods as well as for the cardiac MRI method. The intra-observer variabilities were calculated. The four different echocardiography methods were compared to cardiac MRI using the method described by Bland and Altman. Results: Twenty-five subjects had adequate paired data sets. The mean LVM as measured by cardiac MRI was 162±55 g and for the four different echocardiography methods were: fundamental AL 165±55 g, harmonic AL 168±53 g, fundamental TE 148±50 g, harmonic TE 149±45 g. The intra-observer variability for cardiac MRI method, expressed as bias ± 1 standard deviation of the difference (S.D.D.), was 2.3±9.2 g and for the four different echocardiography methods were: fundamental TE 0.4±26.8 g, fundamental AL 0.6±27.0 g, harmonic TE 6.7±21.8 g, harmonic AL 6.4±22.9 g. The mean LVM for the AL method was closest to the cardiac MRI technique, while TE underestimated LVM. The 95% limits of agreement were consistently wide for all the 2D echocardiography modalities when compared with the cardiac MRI technique. Conclusion: The intra-observer variability in measurements of 2D echocardiographic LVM, together with the wide limits of agreement when compared to the gold standard (cardiac MRI) are sufficiently large to make serial estimates of LVM, of single patients or small groups of subjects, by 2D echocardiography, unreliable

  17. Prognostic Value of Transthoracic Doppler Echocardiography Coronary Flow Velocity Reserve in Patients with Nonculprit Stenosis of Intermediate Severity Early after Primary Percutaneous Coronary Intervention.

    Science.gov (United States)

    Tesic, Milorad; Djordjevic-Dikic, Ana; Giga, Vojislav; Stepanovic, Jelena; Dobric, Milan; Jovanovic, Ivana; Petrovic, Marija; Mehmedbegovic, Zlatko; Milasinovic, Dejan; Dedovic, Vladimir; Zivkovic, Milorad; Juricic, Stefan; Orlic, Dejan; Stojkovic, Sinisa; Vukcevic, Vladan; Stankovic, Goran; Nedeljkovic, Milan; Ostojic, Miodrag; Beleslin, Branko

    2018-04-03

    Treatment of nonculprit coronary stenosis during primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction may be beneficial, but the mode and timing of the intervention are still controversial. The aim of this study was to examine the significance and prognostic value of preserved coronary flow velocity reserve (CFVR) in patients with nonculprit intermediate stenosis early after primary percutaneous coronary intervention. Two hundred thirty patients with remaining intermediate (50%-70%) stenosis of non-infarct-related arteries, in whom CFVR was performed within 7 days after primary percutaneous coronary intervention, were prospectively enrolled. Twenty patients with reduced CFVR and positive results on stress echocardiography or impaired fractional flow reserve underwent revascularization and were not included in further analysis. The final study population of 210 patients (mean age, 58 ± 10 years; 162 men) was divided into two groups on the basis of CFVR: group 1, CFVR > 2 (n = 174), and group 2, CFVR ≤ 2 (n = 36). Cardiac death, nonfatal myocardial infarction, and revascularization of the evaluated vessel were considered adverse events. Mean follow-up duration was 47 ± 16 months. Mean CFVR for the whole group was 2.36 ± 0.40. There were six adverse events (3.4%) related to the nonculprit coronary artery in group 1, including one cardiac death, one ST-segment elevation myocardial infarction, and four revascularizations. In group 2, there were 30 adverse events (83.3%, P  2 of the intermediate nonculprit coronary lesion, deferral of revascularization is safe and associated with excellent long-term clinical outcomes. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  18. Study on Tei index of right ventricular by tissue doppler imaging and the observation point selection

    International Nuclear Information System (INIS)

    Luo Yinli; Wu Ji; Guo Shenglan; Zhang Di; Li Zhixian

    2009-01-01

    Objective: To explore the right ventricular (RV) Tei index in patients with pulmonary hypertension (PH) by tissue Doppler imaging (TDI), and to explore more accurate observation point to obtain Tei index of right ventricular. Methods: Assessment of RV Tei index values was performed in 95 patients with PH and 32 normal subjects. The 95 patients were grouped into 3 groups according to the severity of PH. Tei index values were obtained by TDI measurement from three observation points, the anterior tricuspid and septal tricuspid attachment points in the apical 4-chamber view and the posterior tricuspid attachment point in parasternal right heart 2-chamber review. Results: (1) RV Tel index values were measured at the three points of PH was higher than the normal significantly (P<0.05). (2) RV Tei index values of the three PH groups at he anterior tricuspid attachment had significant difference each other (P<0.05). RV Tei index values of low-grade and medium-grade PH groups at septal tricuspid and posterior tricuspid had no significant difference, but that of high-grade PH group were higher than the low-grade and medium-grade PH group. Conclusion: RV Tei index value was significantly increased in PH patients. The Tei index value measured by TDI at anterior tricuspid attachment point in apical 4-chamber view was better than that at septal tricuspid attachment point in the apical 4-chamber view and posterior' attachment of parasternal right heart 2-chamber. (authors)

  19. Translational and Brownian motion in laser-Doppler flowmetry of large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Seghier, M L; Delpy, D T

    2004-01-01

    This study reports the derivation of a precise mathematical relationship existing between the different p-moments of the power spectrum of the photoelectric current, obtained from a laser-Doppler flowmeter (LDF), and the red blood cell speed. The main purpose is that both the Brownian (defining the 'biological zero') and the translational movements are taken into account, clarifying in this way what the exact contribution of each parameter is to the LDF derived signals. The derivation of the equations is based on the quasi-elastic scattering theory and holds for multiple scattering (i.e. measurements in large tissue volumes and/or very high red blood cell concentration). The paper also discusses why experimentally there exists a range in which the relationship between the first moment of the power spectrum and the average red blood cells speed may be considered as 'linear' and what are the physiological determinants that can result in nonlinearity. A correct way to subtract the biological zero from the LDF data is also proposed. The findings should help in the design of improved LDF instruments and in the interpretation of experimental data

  20. Acute Effects of Hemodialysis on Left and Right Ventricular Function: A Doppler Tissue Imaging Study

    Directory of Open Access Journals (Sweden)

    Tansel Erol

    2012-08-01

    Full Text Available Purpose: Doppler tissue imaging (DTI allows noninvasive assessment of both left ventricular (LV and right ventricular (RV function. The aim of this study was to evaluate the effect of hemodialysis (HD on LV and RV function using DTI. Method: Our study group included 30 patients on chronic HD program (mean age 45 15 years. Myocardial (Sm, Em, Am and annular velocities (Ea, Aa were measured in several cardiac territories before and after HD. Results: After HD, Ea significantly reduced from 10.8 3.4 cm/s to 9.6 2.4 cm/s (p = 0.029. Patients exhibited a lower Em following HD in all measured territories. Em/Am ratio was also reduced for each LV wall investigated after HD in all measured territories. At the RV segments, Sm, Em, and Am decreased significantly in all measured territories. Em of the anterior wall was positively related to ultrafiltration volume (r = 0.25, p = 0.006, whereas the decrease of Sm of RV basal segment correlated with a decrease of diastolic blood pressure (r = 0.23, p < 0.01. Conclusion: Our data indicate that a single HD session is associated with acute changes of systolic and diastolic parameters of LV and RV. [Cukurova Med J 2012; 37(4.000: 215-222

  1. Advanced quantitative echocardiography in arrhythmogenic right ventricular cardiomyopathy

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Hastrup Svendsen, Jesper; Sogaard, Peter

    2007-01-01

    BACKGROUND: Arrhythmogenic right ventricular (RV) cardiomyopathy (ARVC) is a regional disease of the RV myocardium with variable degrees of left ventricular involvement. Three-dimensional echocardiography and Doppler tissue imaging (DTI) are new echocardiographic modalities for the evaluation......, patients with ARVC had a decreased RV ejection fraction (0.47 +/- 0.08 vs 0.53 +/- 0.05, P vs 15.1 +/- 3.7 cm/s, P left ventricle (7.0 +/- 2.6 vs 9.5 +/- 1.9 cm/s, P ... of the longitudinal motility appears to be a sensitive marker of preclinical left ventricular involvement....

  2. Fetal echocardiography

    International Nuclear Information System (INIS)

    Chaubal, Nitin G.; Chaubal, Jyoti

    2009-01-01

    USG performed with a high-end machine, using a good cine-loop facility is extremely helpful in the diagnosis of fetal cardiac anomalies. In fetal echocardiography, the four-chamber view and the outflow-tract view are used to diagnose cardiac anomalies. The most important objective during a targeted anomaly scan is to identify those cases that need a dedicated fetal echocardiogram. Associated truncal and chromosomal anomalies need to be identified. This review shows how fetal echocardiography, apart from identifying structural defects in the fetal heart, can be used to look at rhythm abnormalities and other functional aspects of the fetal heart

  3. Doppler ultrasound for diagnosis of soft tissue sarcoma: efficacy of ultrasound-based screening score

    Directory of Open Access Journals (Sweden)

    Nagano Satoshi

    2015-06-01

    Full Text Available Background. The utility of ultrasound imaging in the screening of soft-part tumours (SPTs has been reported. We classified SPTs according to their blood flow pattern on Doppler ultrasound and re-evaluated the efficacy of this imaging modality as a screening method. Additionally, we combined Doppler ultrasound with several values to improve the diagnostic efficacy and to establish a new diagnostic tool.

  4. Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    Directory of Open Access Journals (Sweden)

    Naylor A Ross

    2003-12-01

    Full Text Available Abstract Background Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI of Arterial Wall Motion (AWM and to quantify simple wall motion indices in normal and diseased carotid arteries. Methods 224 normal and diseased carotid arteries (0–100% stenoses were imaged in 126 patients (age 25–88 years, mean 68 ± 11. Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. Results AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Conclusion Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.

  5. Echocardiography Practice: Insights into Appropriate Clinical Use, Technical Competence and Quality Improvement Program

    Science.gov (United States)

    Kossaify, Antoine; Grollier, Gilles

    2014-01-01

    Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342

  6. Avaliação da anastomose de artéria torácica interna esquerda com artéria interventricular anterior pela ecodopplercardiografia Evaluation of left internal thoracic artery anastomosis with left anterior descending coronary artery by Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Adelaide Arruda

    1997-12-01

    Full Text Available OBJETIVO: Avaliar o valor do ecocardiograma Doppler(ECO transtorácico na identificação de perviabilidade da anastomose entre artéria torácica interna esquerda (ATIE e interventricular anterior, realizada pela técnica de revascularização miocárdica pela minitoracotomia sem circulação extracorpórea. MÉTODOS: Estudaram-se os primeiros 12 pacientes, consecutivos, no período de pós-operatório intra-hospitalar pelo ECO, utilizando-se transdutores de 5MHz, pela via paraesternal esquerda, preferencialmente. Foram analisadas velocidades máximas e integrais de velocidade dos componentes sistólico e diastólico das curvas espectrais de fluxo Doppler. Todos pacientes foram submetidos à cinecoronariografia, enquanto hospitalizados. RESULTADOS: O ECO foi exeqüível em 93% dos pacientes. Nos com anastomose pérvia (6/7, observou-se ao estudo Doppler amplo componente diastólico (padrão A. Naqueles com anastomose obstruída (4/4 o padrão observado foi de predomínio sistólico (padrão B (p=0,003*. CONCLUSÃO: O ECO da ATIE anastomosada com a artéria interventricular anterior, após cirurgia de revascularização miocárdica pela técnica de minitoracotomia, permitiu caracterizar precocemente, com precisão, a perviabilidade da anastomose.PURPOSE: To study the value of Doppler echocardiography as a tool for the evaluation of left internal thoracic artery graft (LITAG patency in patients who underwent coronary revascularization using minimally invasive bypass surgery without extracorporeal circulation. METHODS: The first 12 consecutive patients were studied after coronary artery bypass surgery using a 5MHz Doppler transducer. Doppler signals for the systolic and diastolic flow velocities were preferably obtained in the second intercostal space. All patients underwent coronary angiography while hospitalized. RESULTS: The exam was feasible in 93% of patients. Doppler flow pattern was predominantly diastolic (pattern A in patients with patent

  7. Pulsed-wave tissue Doppler imaging of the myocardium of cats with induced thyrotoxicosis Doppler tecidual pulsado do miocárdio de gatos com tirotoxicose induzida

    Directory of Open Access Journals (Sweden)

    Daniel Capucho de Oliveira

    2011-06-01

    Full Text Available Left ventricular myocardial motion was quantified using pulsed-wave tissue Doppler imaging (PW-TDI in nine adult cats before and after thyrotoxicosis induction. In order to induce thyrotoxicosis, all cats were given 150µg kg-1 of levothyroxine sodium as a single oral dose each day for 10 weeks. PW-TDI examinations were performed immediately before the induction and by the end of the experimental protocol. An increase in myocardial motion velocity was documented at the interventricular septum level, demonstrated by an elevation in systolic (Sa, and early (Ea and late (Aa diastolic waves (PA velocidade de movimentação miocárdica do ventrículo esquerdo foi quantificada por meio de exames ecocardiográficos com Doppler tecidual pulsado (PW-TDI em nove gatos adultos antes e após indução à tirotoxicose. Para indução da tirotoxicose, todos os gatos receberam doses diárias de 150mg kg-1 de levotiroxina sódica, por via oral, durante 10 semanas. Os exames de PW-TDI foram realizados imediatamente antes da indução e ao final do protocolo experimental. Uma elevação na velocidade de movimentação miocárdica foi documentada ao nível do septo interventricular, demonstrado por um aumento das ondas sistólica (Sa e diastólicas (Ea e Aa; P<0,05. No entanto, nenhuma alteração nos valores de Sa, Ea e Aa foi encontrada ao nível da parede livre do ventrículo esquerdo. A frequência cardíaca aumentou significativamente entre os momentos experimentais, sendo que três animais apresentaram fusão das ondas Aa e Ea ao final do experimento. O protocolo experimental utilizado neste estudo causou alterações na velocidade de movimentação do miocárdio ventricular esquerdo, mas sem causar danos à função diastólica do ventrículo esquerdo.

  8. Contrast echocardiography: history, micro bubble characteristics and instrumental techniques

    International Nuclear Information System (INIS)

    Cubides, Carlos; Restrepo, Gustavo; Aristizabal, Dagnovar; Munera, Ana

    2006-01-01

    This article describes the history of contrast echocardiography, the physical characteristics of the contrast agent's micro bubbles, the main instrumental tools (mechanical index, focus and focusing, frame rate), and the echocardiography techniques (second harmonic imaging, fusion harmonic, power pulse inversion imaging, triggered imaging, intermittent harmonic power Doppler, color power angio and acoustic densitometry), actually available for clinical use

  9. Utilization of laser Doppler flowmetry and tissue spectrophotometry for burn depth assessment using a miniature swine model.

    Science.gov (United States)

    Lotter, Oliver; Held, Manuel; Schiefer, Jennifer; Werner, Ole; Medved, Fabian; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Jaminet, Patrick; Rothenberger, Jens

    2015-01-01

    Currently, the diagnosis of burn depth is primarily based on a visual assessment and can be dependent on the surgeons' experience. The goal of this study was to determine the ability of laser Doppler flowmeter combined with a tissue spectrophotometer to discriminate burn depth in a miniature swine burn model. Burn injuries of varying depth, including superficial-partial, deep-partial, and full thickness, were created in seven Göttingen minipigs using an aluminium bar (100 °C), which was applied to the abdominal skin for periods of 1, 3, 6, 12, 30, and 60 seconds with gravity alone. The depth of injury was evaluated histologically using hematoxylin and eosin staining. All burns were assessed 3 hours after injury using a device that combines a laser light and a white light to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. The blood flow (41 vs. 124 arbitrary units [AU]) and relative amount of hemoglobin (32 vs. 52 AU) were significantly lower in full thickness compared with superficial-partial thickness burns. However, no significant differences in hemoglobin oxygenation were observed between these depths of burns (61 vs. 60%). These results show the ability of laser Doppler flowmeter and tissue spectrophotometer in combination to discriminate between various depths of injury in the minipig model, suggesting that this device may offer a valuable tool for burn depth assessment influencing burn management. © 2014 by the Wound Healing Society.

  10. Mechanical Dyssynchrony by Tissue Doppler Cross-Correlation is Associated with Risk for Complex Ventricular Arrhythmias after Cardiac Resynchronization Therapy

    DEFF Research Database (Denmark)

    Tayal, Bhupendar; Gorcsan, John; Delgado-Montero, Antonia

    2015-01-01

    BACKGROUND: Tissue Doppler cross-correlation analysis has been shown to be associated with long-term survival after cardiac resynchronization defibrillator therapy (CRT-D). Its association with ventricular arrhythmia (VA) is unknown. METHODS: From two centers 151 CRT-D patients (New York Heart...... Association functional classes II-IV, ejection fraction ≤ 35%, and QRS duration ≥ 120 msec) were prospectively included. Tissue Doppler cross-correlation analysis of myocardial acceleration curves from the basal segments in the apical views both at baseline and 6 months after CRT-D implantation was performed...... with a substantially increased risk for VA (hazard ratio [HR], 4.4; 95% CI, 1.2-16.3; P = .03) and VA or death (HR, 4.0; 95% CI, 1.7-9.6; P = .002) after adjusting for other covariates. Similarly, patients with new dyssynchrony had increased risk for VA (HR, 10.6; 95% CI, 2.8-40.4; P = .001) and VA or death (HR, 5...

  11. What Is Echocardiography?

    Science.gov (United States)

    ... Intramural Research Home / Echocardiography Echocardiography Also known as Echo , Surface echo , Ultrasound of ... other tests, echo doesn't involve radiation. Transthoracic Echocardiography Transthoracic (tranz-thor-AS-ik) echo is the ...

  12. Computed estimates of maximum temperature elevations in fetal tissues during transabdominal pulsed Doppler examinations.

    Science.gov (United States)

    Bly, S H; Vlahovich, S; Mabee, P R; Hussey, R G

    1992-01-01

    Measured characteristics of ultrasonic fields were obtained in submissions from manufacturers of diagnostic ultrasound equipment for devices operating in pulsed Doppler mode. Simple formulae were used with these data to generate upper limits to fetal temperature elevations, delta Tlim, during a transabdominal pulsed Doppler examination. A total of 236 items were analyzed, each item being a console/transducer/operating-mode/intended-use combination, for which the spatial-peak temporal-average intensity, ISPTA, was greater than 500 mW cm-2. The largest calculated delta Tlim values were approximately 1.5, 7.1 and 8.7 degrees C for first-, second- and third-trimester examinations, respectively. The vast majority of items yielded delta Tlim values which were less than 1 degree C in the first trimester. For second- and third-trimester examinations, where heating of fetal bone determines delta Tlim, most delta Tlim values were less than 4 degrees C. The clinical significance of the results is discussed.

  13. Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy

    NARCIS (Netherlands)

    O.I.I. Soliman (Osama Ibrahim Ibrahim); D.A.M.J. Theuns (Dominic); M.L. Geleijnse (Marcel); A. Nemes (Attila); K. Caliskan (Kadir); W.B. Vletter (Wim); L.J.L.M. Jordaens (Luc); F.J. ten Cate (Folkert)

    2007-01-01

    textabstractAims: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) ≥60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). Methods and results

  14. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    International Nuclear Information System (INIS)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-01-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by 133 Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133 Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133 Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and 133 Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes. (author)

  15. Comparison between /sup 133/Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    Energy Technology Data Exchange (ETDEWEB)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-10-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by /sup 133/Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and /sup 133/Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The /sup 133/Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and /sup 133/Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes.

  16. Integrated quadruple stress echocardiography.

    Science.gov (United States)

    Picano, Eugenio; Morrone, Doralisa; Scali, Maria C; Huqi, Alda; Coviello, Katia; Ciampi, Quirino

    2018-04-11

    Stress Echocardiography (SE) is an established diagnostic technique. For 40 years, the cornerstone of the technique has been the detection of regional wall motion abnormalities (RWMA), due to the underlying physiologically-relevant epicardial coronary artery stenosis. In the last decade, three new parameters (more objective than RWMA) have shown the potential to integrate and comple- ment RWMA: 1- B-lines, also known as ultrasound lung comets, as a marker of extra-vascular lung water, measured using lung ultrasound with the 4-site simplified scan symmetrically of the antero- lateral thorax on the third intercostal space, from mid-axillary to anterior axillary and mid- clavicular line; 2-left ventricular contractile reserve (LVCR), assessed as the peak stress/rest ratio of left ventricular force, also known as elastance (systolic arterial pressure by cuff sphygmomanome- ter/end-systolic volume from 2D echocardiography); 3- coronary flow velocity reserve (CFVR) on left anterior descending coronary artery, calculated as peak stress/rest ratio of diastolic peak flow velocity assessed using pulsed-wave Doppler. The 4 parameters (RWMA, B-lines, LVCR and CFVR) now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-SE. IQ-SE optimizes the versatility of SE to include in a one-stop shop the core "ABCD" (Asynergy+B-lines+Contractile reserve+Doppler flowmetry) protocol. It allows a synoptic assess- ment of parameters mirroring the epicardial artery stenosis (RWMA), interstitial lung water (B- lines), myocardial function (LVCR) and small coronary vessels (CFVR). Each variable has a clear clinical correlate, different and complementary to all others: RWMA identify an ischemic vs non- ischemic heart; B-lines a wet vs dry lung; LVCR a strong vs weak heart; CFVR a warm vs cold heart. IQ-SE is highly feasible, with minimal increase in the imaging and analysis time, and obvi- ous diagnostic and prognostic impact also beyond coronary artery

  17. Invasive and noninvasive assessment of pulmonic regurgitation: clinical, angiographic, phonocardiographic, echocardiographic, and Doppler ultrasound correlations.

    Science.gov (United States)

    Chandraratna, P A; Wilson, D; Imaizumi, T; Ritter, W S; Aronow, W S

    1982-06-01

    Three patients with pulmonic regurgitation and no evidence of pulmonary hypertension were investigated. These patients had low pitched diastolic murmurs which increased on inspiration, evidence of connective tissue disease as manifested by lax joints and hyperextensible skin, and marked hilar dance which extended up to the peripheral vessels. Suprasternal echocardiography revealed dilatation and increased systolic expansion of the right pulmonary artery (RPA) (25% and 28%, respectively) in two patients; the third patient had a normal RPA dimension in diastole and a marked increase in diameter (88%) in systole. Thus, these three patients demonstrated hyperdistensibility of the RPA. The spectral signal from the pulsed doppler echocardiograph showed evidence of turbulent blood flow in diastole (wide dispersion of the dots) in the right ventricular outflow tract in all three patients. This pattern was indicative of pulmonic regurgitation. In summary, the combined use of echocardiography and Doppler ultrasound is useful in the evaluation of patients with pulmonic regurgitation.

  18. In situ monitoring of localized shear stress and fluid flow within developing tissue constructs by Doppler optical coherence tomography

    Science.gov (United States)

    Jia, Yali; Bagnaninchi, Pierre O.; Wang, Ruikang K.

    2008-02-01

    Mechanical stimuli can be introduced to three dimensional (3D) cell cultures by use of perfusion bioreactor. Especially in musculoskeletal tissues, shear stress caused by fluid flow generally increase extra-cellular matrix (ECM) production and cell proliferation. The relationship between the shear stress and the tissue development in situ is complicated because of the non-uniform pore distribution within the cell-seeded scaffold. In this study, we firstly demonstrated that Doppler optical coherence tomography (DOCT) is capable of monitoring localized fluid flow and shear stress in the complex porous scaffold by examining their variation trends at perfusion rate of 5, 8, 10 and 12 ml/hr. Then, we developed the 3D porous cellular constructs, cell-seeded chitosan scaffolds monitored during several days by DOCT. The fiber based fourier domain DOCT employed a 1300 nm superluminescent diode with a bandwidth of 52 nm and a xyz resolution of 20×20×15 μm in free space. This setup allowed us not only to assess the cell growth and ECM deposition by observing their different scattering behaviors but also to further investigate how the cell attachment and ECM production has the effect on the flow shear stress and the relationship between flow rate and shear stress in the developing tissue construct. The possibility to monitor continuously the constructs under perfusion will easily indicate the effect of flow rate or shear stress on the cell viability and cell proliferation, and then discriminate the perfusion parameters affecting the pre-tissue formation rate growth.

  19. Determining the appropriate number and duration of leech therapy in congested tissues using tissue spectrophotometry and laser Doppler flowmetry.

    Science.gov (United States)

    Rothenberger, Jens; Petersen, Wiebke; Schaller, Hans-Eberhard; Held, Manuel

    2016-11-01

    A universal protocol determining the number of leeches and their application time does not exist. The aim of this study, therefore, is to quantify perfusion dynamics in venous congested tissues after leech application to get more detailed information about changes due to leech-induced skin microcirculation and to evaluate the usability of the Oxygen to See (O2C) device in terms of determining the appropriate number of leeches and the duration of therapy. Twelve patients with the need for leech therapy participated in the study. Perfusion dynamics of the congested tissue was assessed using the O2C device, which determines blood flow (BF), the relative amount of hemoglobin (rHB), and the oxygen saturation (SO2). Measurements were carried out before leech application and on various intervals like 10 minutes, one hour, and three hours after leech application. The leech application effectuated after 10 minutes a nonsignificant perfusion improvement, which further increased after one hour with a significant reduction of the relative amount of hemoglobin and a significant increase of blood flow and oxygen saturation (BF= +56.7%; rHB= -25.5%; SO2= +53.7%). After three hours, the values returned to the levels before leech administration. In two cases, in which further administration of leeches within the measurement period was necessary, no substantial perfusion changes were obtained. The results of this study forms a more precise pattern of microcirculatory changes of leech therapy in congested tissues. According to our measurements a venous drainage improvement can be expected in congested tissue one hour after leech administration. The O2C seems to be a useful method to determine the appropriate number and duration of leech therapy. © 2016 by the Wound Healing Society.

  20. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  1. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    DEFF Research Database (Denmark)

    Kastrup, J; Bülow, J; Lassen, N A

    1987-01-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by 133Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vasoconstrictor reflex by lowering the area of investigation below heart...... forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133Xenon method recorded a 44% decrease in blood flow in innervated...... level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133Xenon blood flow measurements were performed simultaneously on the sympathetically denervated...

  2. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  3. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  4. [Is standard-echocardiography sufficient for identification of responders?].

    Science.gov (United States)

    Neuss, M; Flach, P; Ali, T; Butter, C

    2006-01-01

    During recent years cardiac re-synchronization has become an important tool in the treatment of patients with signs and symptoms of heart failure and de-synchronized contraction of the heart. This article describes the pathophysiological basis of de-synchronized contraction due to left bundle branch block and the use of conventional echocardiography to unmask whether the electrical abnormality is accompanied by an asynchronous contraction in the individual patient. The altered contraction in the de-synchronized heart is analysed on different levels: atrioventricular dyssynchrony describes the disturbed mechanical coupling of the ventricles and atria, interventricular dyssynchrony describes the disturbed mechanical coupling of the left and right ventricle, and intraventricular dyssynchrony describes the uncoordinated contraction of the left ventricle. Since tissue Doppler imaging is implemented only in the top level echo machines of the respective manufacturers, this article uses parameters derived from standard echo techniques to analyse the different aspects of dyssynchrony.

  5. American Society of Echocardiography

    Science.gov (United States)

    American Society of Echocardiography Join Ase Renew Member Portal Log In Membership Member Portal Log In Join ASE Renew Benefits Rates FASE – Fellow of the American Society of Echocardiography Member Referral Program FAQs Initiatives Advocacy Awards, Grants, ...

  6. The practice of echocardiography

    International Nuclear Information System (INIS)

    Kraus, R.

    1985-01-01

    This volume is an anthology by noted authorities on all clinically useful aspects of echocardiography. Its articles cover such subjects as: historical perspectives, physics, instrumentation and techniques, M mode and 2D echocardiography

  7. Prevalência de hipertensão pulmonar avaliada por ecocardiografia Doppler em uma população de pacientes adolescentes e adultos com fibrose cística Prevalence of pulmonary hypertension evaluated by Doppler echocardiography in a population of adolescent and adult patients with cystic fibrosis

    Directory of Open Access Journals (Sweden)

    Paula Maria Eidt Rovedder

    2008-02-01

    Full Text Available OBJETIVO: Determinar a prevalência de hipertensão pulmonar (HP em pacientes com fibrose cística (FC, comparar características clínicas, escore radiológico, função pulmonar e parâmetros ecocardiográficos nos grupos com e sem HP e correlacionar achados ecocardiográficos com características clínicas, escore radiológico e função pulmonar. MÉTODOS: Estudo transversal prospectivo em pacientes clinicamente estáveis (idade > 16 anos atendidos por um programa de adultos para FC. Os pacientes foram submetidos a avaliação clínica, ecocardiografia Doppler, testes de função pulmonar e exame radiológico do tórax. RESULTADOS: Obteve-se a velocidade de regurgitação tricúspide (VRT em 37 dos 40 pacientes estudados. A prevalência de HP foi de 49% com um ponte de corte da VRT de 2,5 m/s (18 pacientes e de 30% com um ponte de corte da VRT de 2,8 m/s (11 pacientes. Os valores de saturação periférica de oxigênio (SpO2 em repouso, escore clínico, volume expiratório forçado no primeiro segundo (VEF1 e capacidade vital forçada (CVF foram significativamente menores no grupo com HP. A VRT correlacionou-se significativamente com SpO2 em repouso (p OBJECTIVE: To determine the prevalence of pulmonary hypertension (PH in patients with cystic fibrosis (CF, to compare clinical characteristics, radiographic scores, pulmonary function, and echocardiographic parameters in patients with and without PH, and to correlate echocardiographic findings with clinical characteristics, radiographic scores, and pulmonary function. METHODS: This was a prospective, cross-sectional study involving clinically stable patients (aged 16 or older enrolled in an adult CF program. The patients were submitted to clinical evaluation, Doppler echocardiography, pulmonary function tests, and chest X-rays. RESULTS: Tricuspid regurgitant jet velocity (TRV was obtained in 37 of the 40 patients studied. The prevalence of PH was 49% with a TRV cut-off of 2.5 m/s (18 patients

  8. Can tissue spectrophotometry and laser Doppler flowmetry help to identify patients at risk for wound healing disorders after neck dissection?

    Science.gov (United States)

    Rohleder, Nils H; Flensberg, Sandra; Bauer, Florian; Wagenpfeil, Stefan; Wales, Craig J; Koerdt, Steffen; Wolff, Klaus D; Hölzle, Frank; Steiner, Timm; Kesting, Marco R

    2014-03-01

    Microcirculation and oxygen supply in cervical skin were measured with an optical, noninvasive method in patients with or without radiotherapy before neck dissection. The course of wound healing was monitored after the surgical procedure to identify predictive factors for postoperative wound healing disorders. Tissue spectrophotometry and laser Doppler flowmetry were used to determine capillary oxygen saturation, hemoglobin concentration, blood flow, and blood velocity at 2-mm and 8-mm depths in the cervical skin of 91 patients before neck dissection in a maxillofacial unit of a university hospital in Munich, Germany. Parameters were evaluated for differences between patients with irradiation (24) and without (67) and patients with wound healing disorders (25) and without (66) (univariate or multivariate statistical analyses). Velocity at 2 mm was lower in irradiated skin (P = .016). Flow at 2 mm was higher in patients with wound healing disorders (P = .018). High flow values could help to identify patients at risk for cervical wound healing disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Coronary flow velocity reserve by echocardiography

    DEFF Research Database (Denmark)

    Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Snoer, Martin

    2016-01-01

    BACKGROUND: Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography of the LAD is used to assess microvascular function but validation studies in clinical settings are lacking. We aimed to assess feasibility, reproducibility and agreement with myocardial flow...... performed within a week (1-week) and for all scans regardless of time gap (total) and to account for scar tissue for patients with and without previous myocardial infarction (MI). RESULTS: Eighty-six patients with median BMI 30.9 (IQR 29.4-32.9) kg × m(-2) and CFVR 2.29 (1.90-2.63) were included. CFVR...... was feasible in 83 (97 %) using a contrast agent in 14 %. For reproducibility overall (n = 21) limits of agreement (LOA) were (-0.75;0.71), within-subjects coefficient of variation (CV) 11 %, and reliability 0.84. For reproducibility within 1-week (n = 13) LOA were (-0.33;0.25), within-subjects CV 5...

  10. Echocardiography as an approach for canine cardiac disease diagnosis

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-11-01

    Full Text Available Aim: The aim of the study was to establish the methods for diagnosis various canine cardiac ailments using echocardiography. Materials and Methods: M-mode, two-dimensional echocardiography and Doppler studies were performed on 10 cases. Dogs showing signs of cardiac ailment either clinically, radiographic or via electrocardiographic examination were selected for study. Right parasternal short axis view was used for echocardiographic measurements. Right parasternal long axis and left parasternal apical views were used for Doppler studies. Doppler studies were performed at the level of aortic valve and atrioventricular valves for semi quantitative diagnosis of regurgitation. Results: Dogs were found affected with dilated cardiomyopathy (DCM (n=5, pericardial effusion (PE (n=1, combined PE and DCM (n=2 and remaining two showed abnormality on radiographic or electrographically evaluation but were found out to be normal echocardiographically (n=2. Conclusion: Echocardiography is an effective tool for diagnosis of various heart ailments.

  11. Retinopathy is associated with impaired myocardial function assessed by advanced echocardiography in type 1 diabetes patients – The Thousand & 1 Study

    DEFF Research Database (Denmark)

    Nouhravesh, Nina; Andersen, Henrik U; Jensen, Jan S

    2016-01-01

    AIMS: Retinopathy and heart disease in Type 1 Diabetes Mellitus (Type 1 DM) may be associated; however previous results have been conflicting. Tissue Doppler Imaging (TDI) and speckle-tracking echocardiography (STE) quantify myocardial function not assessable by conventional echocardiography. We...... investigated the association between severity of retinopathy and early myocardial dysfunction using conventional echocardiography, TDI and STE in Type 1 DM patients. METHODS: Type 1 Diabetes Mellitus patients without known heart disease were included from the Steno Diabetes Center. The cross sectional...... association between retinopathy and myocardial function was analyzed in uni-and multivariable models. Retinopathy was categorized as nil-, simplex- or proliferative retinopathy. RESULTS: A total of 1090 Type 1 Diabetes Mellitus patients were included, mean age was 49.6years and 53% were males. Left...

  12. Prognostic value of cardiac time intervals measured by tissue Doppler imaging M-mode in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Jensen, Jan Skov

    2015-01-01

    : In a large prospective community-based study, cardiac function was evaluated in 1915 participants by both conventional echocardiography and TDI. The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT) and ejection time (ET), were obtained by TDI M...

  13. MRI and echocardiography in the diagnosis of cardiac amyloidosis

    International Nuclear Information System (INIS)

    Wang Jing; Kong Xiangquan; Zhou Guofeng; Xu Haibo; Chang Dandan; Feng Yiming; Liu Dingxi; Zhang Li; Xie Mingxing

    2010-01-01

    Objective: To assess the values of MRI and echocardiography for the diagnosis of cardiac amyloidosis (CA). Methods: Eleven cases with CA proved pathologically performed MRI and echocardiography, the findings were analyzed retrospectively. Results: The characteristic features of cardiac amyloidosis on MRI and echocardiography were: diffuse slight myocardial thickening of the left ventricular wall and interventricular septum (11 cases), slight myocardial thickening of the interatrial septum (5 cases), increased left ventricular mass (7 cases), enlarged left atrium (7 cases), impaired ventricular systolic and diastolic function (10 cases), pleural and pericardial effusions (11 and 9 cases). Echocardiography showed that myocardium was hyperechoic and presented as ground glass with some spotty hyperechoes in 6 cases. MRI revealed a distinct diffuse delayed enhancement of subendocardial and entire myocardium in 8 cases. Conclusion: Doppler echocardiography is the first-choice imaging technique and cardiac magnetic resonance imaging can provide more information for the diagnosis of CA. (authors)

  14. The usefulness of plasma asymmetric dimethylarginine (ADMA) levels and tissue doppler echocardiography for heart function in term infants born to mothers with gestational diabetes mellitus.

    Science.gov (United States)

    Arslan, Derya; Oran, Bulent; Vatansev, Husamettin; Cimen, Derya; Guvenc, Osman

    2013-11-01

    The aim of this study was to examine whether asymmetric dimethylarginine (ADMA) concentrations are associated with ventricular function in the infants of mothers with gestational diabetes. Twenty-five term newborns of mothers with gestational diabetes and term newborns as the control group (n = 25) with normal general health status were evaluated at two time points, on the 3rd postnatal day, at the 3th months. Echocardiographic evaluations of all participants were performed and ADMA level was measured. In the first analysis, 10 patients (40%) had a septal thickness of 6 mm or more, indicating septal hypertrophy. In the first and second analysis, interventricular septum end-diastolic thickness (IVSTd) and the left ventricular posterior wall end-diastolic thickness (LVPWTd) in the patient group were higher than the control group. ADMA level measurement was not significantly different between the groups the first and second analysis. There was no difference in ADMA levels of the group with septal thickness ≥6 mm and the group with Gestational diabetes mellitus (GDM), and the increase was independent of glycemic control. Diastolic newborn cardiac function was impaired in GDM, and this effect was independent of septal thickness. We found no association between ADMA levels and cardiac systolic, diastolic functions or septum thickness in the GDM newborn.

  15. Reduced systolic performance by tissue Doppler in patients with preserved and abnormal ejection fraction: new insights in chronic heart failure.

    Science.gov (United States)

    García, Edgar H; Perna, Eduardo R; Farías, Eduardo F; Obregón, Ricardo O; Macin, Stella M; Parras, Jorge I; Agüero, Marcelo A; Moratorio, Diego A; Pitzus, Ariel E; Tassano, Eduardo A; Rodriguez, Leonardo

    2006-04-04

    Tissue Doppler imaging (TDI) is useful in the evaluation of systolic and diastolic function. It allows assessment of ventricular dynamics in its longitudinal axis. We sought to investigate the difference in systolic and diastolic longitudinal function in patients with chronic heart failure (CHF) with normal and reduced ejection fraction. One hundred ten outpatients with CHF and 68 controls were included. Ejection fraction (EF) was obtained and longitudinal systolic (S) and diastolic (E' and A') wall velocities were recorded from basal septum. Group A (controls) were normal and CHF patients were classified by EF in Group B1: > 45% and B2: < or = 45%. In A, B1 and B2 the mean S peak was 7.74; 5.45 and 4.89 cm/s (p<0.001); the mean E' peak was 8.56; 5.72 and 6.1 cm/s (p<0.001); and the mean A' peak was 10.2; 7.3 and 5.3 cm/s (p<0.001). Also, isovolumic contraction and relaxation time were different among control and CHF groups, (both p<0.001). The most useful parameters for identifying diastolic CHF were IVRT and S peak, with area under ROC curves of 0.93 and 0.89. The cut-off of 115 ms for IVRT and 5.8 cm/s for S peak showed a sensitivity of 94 and 97%, with a specificity of 82 and 73%, respectively. These findings suggest that impairment of left ventricular systolic function is present even in those with diastolic heart failure, and that abnormalities may have an important role to identifying the condition.

  16. Left ventricular diastolic dyssynchrony assessed with phase analysis of gated myocardial perfusion SPECT: a comparison with tissue Doppler imaging

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Veltman, Caroline E.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Mooyaart, Eline A.Q.; Wall, Ernst E. van der; Schalij, Martin J.; Bax, Jeroen J.; Delgado, Victoria; Younis, Imad Al; Hiel, Bernies van der; Dibbets-Schneider, Petra

    2011-01-01

    The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p 55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4 vs. 40.7 ± 14.0 , p < 0.01) and diastolic HBW (230.6 ± 54.3 vs. 129.0 ± 55.6 , p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony. (orig.)

  17. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    Science.gov (United States)

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Assessment of left ventricular regional function in affected and carrier dogs with duchenne muscular dystrophy using speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Yugeta Naoko

    2011-05-01

    Full Text Available Abstract Background Two-dimensional speckle tracking echocardiography (STE is a relatively new method to detect regional myocardial dysfunction. To assess left ventricular (LV regional myocardial dysfunction using STE in Duchenne muscular dystrophy model dogs (CXMDJ without overt clinical signs of heart failure. Methods Six affected dogs, 8 carrier dogs with CXMDJ, and 8 control dogs were used. Conventional echocardiography, systolic and diastolic function by Doppler echocardiography, tissue Doppler imaging (TDI, and strain indices using STE, were assessed and compared among the 3 groups. Results Significant differences were seen in body weight, transmitral E wave and E' wave derived from TDI among the 3 groups. Although no significant difference was observed in any global strain indices, in segmental analysis, the peak radial strain rate during early diastole in posterior segment at chordae the tendineae level showed significant differences among the 3 groups. Conclusions The myocardial strain rate by STE served to detect the impaired cardiac diastolic function in CXMDJ without any obvious LV dilation or clinical signs. The radial strain rate may be a useful parameter to detect early myocardial impairment in CXMDJ.

  19. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  20. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  1. Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2008-01-01

    Full Text Available Abstract Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures.

  2. The importance of echocardiography in diagnostics of idiopathic pulmonary arterial hypertension: A case report

    Directory of Open Access Journals (Sweden)

    Stojković Gabrijela

    2011-01-01

    Full Text Available Introduction. Idiopathic pulmonary arterial hypertension (IPAH is rare and difficult progressive disease with prevalence of approximately 15 cases per million residents, with predominant female cases. Case Outline. A 47-year-old female presented with symptoms and signs of the right heart chambers failure. Over prior seven years the patient had the feeling of suffocation and fatigue when walking, and received treatment for bronchial asthma. Physical examination revealed a marked loud second heart sound over the pulmonary artery. Electrocardiogram: right ventricular hypertrophy. Spirometric (pulmonary capacity test, cardiac perfusion scan and spiral CT scanning excluded secondary pulmonary arterial hypertension. Blood testing for connective tissue diseases and HIV were within normal reference limits. Transthoracic colour Doppler echocardiography demonstrated a mild tricuspid regurgitation with high values of estimated maximal and middle systolic pressure of the right ventricle (135/110 mm Hg, and excluded previous heart disease. Cardiac catheterization confirmed IPAH diagnosis, with systolic right ventricular pressure of 101/47/66 mm Hg and pulmonary capillary pressure of 30/13/10 mm Hg. Basic therapy with sildenafil, nevertheless, considerable limitations of strain tolerance was still present. Conclusion. IPAH is a severe heart disease with non-specific signs and symptoms. Screening for IPAH is transthoracic colour Doppler echocardiography shows high correlation with cardiac catheterization.

  3. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Haahr-Pedersen, Sune Ammentorp

    2011-01-01

    The objective of this study was to evaluate the prognostic value of the myocardial performance index (MPI), assessed by color-coded tissue Doppler imaging (TDI) M-mode through the anterior mitral leaflet. Color TDI M-mode through the mitral leaflet is an easy, very fast, and precise method...... ventricular in- and outflow using standard procedures (MPI(conv)) and by color-coded TDI M-mode through the mitral leaflet in the apical 4-chamber view (MPI(TDI)). MPI(TDI) was increased in subjects with coronary heart disease (CHD) compared to controls, even after multivariable adjustment (p

  4. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  5. Novel techniques in stress echocardiography: a focus on the advantages and disadvantages.

    Science.gov (United States)

    Vamvakidou, Anastasia; Gurunathan, Sothinathan; Senior, Roxy

    2016-01-01

    Stress echocardiography (SE) is an established tool not only for the assessment of coronary artery disease (CAD), but also for the evaluation of valvular disease and cardiomyopathy. New techniques, namely contrast echocardiography for function and perfusion including assessment of coronary flow reserve, strain imaging, 3-dimensional echocardiography, Doppler-derived coronary flow reserve and multimodality echocardiography, have been incorporated into stress protocols for improving assessment of cardiac disease. In this review, the advantages and disadvantages of these novel SE techniques are examined in terms of feasibility, accuracy, reproducibility and applications.

  6. Assessment of sustained effects of levosimendan and dobutamine on left ventricular systolic functions by using novel tissue Doppler derived indices in patients with advanced heart failure.

    Science.gov (United States)

    Oner, Ender; Erturk, Mehmet; Birant, Ali; Kurtar Mansıroglu, Aslı; Akturk, Ibrahim Faruk; Karakurt, Huseyin; Yalcin, Ahmet Arif; Uzun, Fatih; Somuncu, Mustafa Umut; Yildirim, Aydin

    2015-01-01

    Previous studies comparing levosimendan vs. dobutamine have revealed that levosimendan is better in relieving symptoms. Echocardiographic studies have been done using second measurements immediately following a dobutamine infusion or while it was still being administered. The aim of our study was assessment of sustained effects of 24 h levosimendan and dobutamine infusions on left ventricular systolic functions. A total of 61 patients with acutely decompensated heart failure with New York Heart Association (NYHA) class III or IV symptoms were randomized to receive either levosimendan or dobutamine 2:1 in an open label fashion. Before and 5 days after the initiation of infusions, functional class was assessed, N-terminal prohormone of B-type natriuretic peptide (NT-proBNP) levels and left ventricular ejection fraction (LVEF), mitral inflow peak E and A wave velocity, and E/A ratios were measured; using tissue Doppler imaging, isovolumic myocardial acceleration (IVA), peak myocardial velocity during isovolumic contraction (IVV), peak systolic velocity during ejection period (Sa), early (E') and late (A') diastolic velocities, and E'/A' and E/E' ratios were measured. The NYHA class improved in both groups, but improvements were prominent in the levosimendan group. NT-proBNP levels were significantly reduced in the levosimendan group. Improvements in LVEF and diastolic indices were significant in the levosimendan group. Tissue Doppler-derived systolic indices of IVV and IVA increased significantly in the levosimendan group. Improvements in left ventricular systolic and diastolic functions continue after a levosimendan infusion.

  7. Mechanical dyssynchrony evaluated by tissue Doppler cross-correlation analysis is associated with long-term survival in patients after cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Risum, Niels; Williams, Eric S; Khouri, Michel G

    2013-01-01

    Aims Pre-implant assessment of longitudinal mechanical dyssynchrony using cross-correlation analysis (XCA) was tested for association with long-term survival and compared with other tissue Doppler imaging (TDI)-derived indices. Methods and results In 131 patients referred for cardiac resynchroniz......Aims Pre-implant assessment of longitudinal mechanical dyssynchrony using cross-correlation analysis (XCA) was tested for association with long-term survival and compared with other tissue Doppler imaging (TDI)-derived indices. Methods and results In 131 patients referred for cardiac......-max was independently associated with improved survival when adjusted for QRS > 150 ms and aetiology {hazard ratio (HR) 0.35 [95% confidence interval (CI) 0.16-0.77], P = 0.01}. Maximal activation delay performed significantly better than Yu index, OWD, and the presence of left bundle branch block (P ..., for difference between parameters). In subgroup analysis, patients without dyssynchrony and QRS between 120 and 150 ms showed a particularly poor survival [HR 4.3 (95% CI 1.46-12.59), P

  8. Clinical Stress Echocardiography

    NARCIS (Netherlands)

    S.E. Karagiannis

    2007-01-01

    textabstractTwo-dimensional echocardiography is a commonly used non-invasive method for the assessment of left ventricular function. It provides precise information on both global and segmental myocardial function by displaying endocardial motion and wall thickening. Dobutamine stress

  9. The Myocardial Performance Index During Low Dose Dobutamine Echocardiography in Normals and Patients With a Recent Myocardial Infarction

    DEFF Research Database (Denmark)

    Nørager, Betina; Husic, Mirza; Møller, Jacob E

    2004-01-01

    BACKGROUND: Wall-motion analysis during low-dose dobutamine echocardiography (LDDE) is a semiquantitative measure of left ventricular contractile reserve after myocardial infarction (MI). The Doppler echocardiographic myocardial performance index (MPI) is a quantitative measure of combined left...

  10. Utility of Tissue Doppler Imaging in the Echocardiographic Evaluation of Left and Right Ventricular Function in Dogs with Myxomatous Mitral Valve Disease with or without Pulmonary Hypertension.

    Science.gov (United States)

    Baron Toaldo, M; Poser, H; Menciotti, G; Battaia, S; Contiero, B; Cipone, M; Diana, A; Mazzotta, E; Guglielmini, C

    2016-05-01

    In human medicine, right ventricular (RV) functional parameters represent a tool for risk stratification in patients with congestive heart failure caused by left heart disease. Little is known about RV alterations in dogs with left-sided cardiac disorders. To assess RV and left ventricular (LV) function in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH). One-hundred and fourteen dogs: 28 healthy controls and 86 dogs with MMVD at different stages. Prospective observational study. Animals were classified as healthy or having MMVD at different stages of severity and according to presence or absence of PH. Twenty-eight morphological, echo-Doppler, and tissue Doppler imaging (TDI) variables were measured and comparison among groups and correlations between LV and RV parameters were studied. No differences were found among groups regarding RV echo-Doppler and TDI variables. Sixteen significant correlations were found between RV TDI and left heart echocardiographic variables. Dogs with PH had significantly higher transmitral E wave peak velocity and higher E/e' ratio of septal (sMV) and lateral (pMV) mitral annulus. These 2 variables were found to predict presence of PH with a sensitivity of 84 and 72%, and a specificity of 71 and 80% at cut-off values of 10 and 9.33 for sMV E/e' and pMV E/e', respectively. No association between variables of RV function and different MMVD stage and severity of PH could be detected. Some relationships were found between echocardiographic variables of right and left ventricular function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. Three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Buck, Thomas

    2011-01-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  12. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    Science.gov (United States)

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135

  13. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention...

  14. Archeological Echocardiography: Digitization and Speckle Tracking Analysis of Archival Echocardiograms in the HyperGEN Study.

    Science.gov (United States)

    Aguilar, Frank G; Selvaraj, Senthil; Martinez, Eva E; Katz, Daniel H; Beussink, Lauren; Kim, Kwang-Youn A; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R; Arnett, Donna K; Shah, Sanjiv J

    2016-03-01

    Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. In the NHLBI HyperGEN study (N = 2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter-/intra-observer agreement was calculated. Accuracy was evaluated in: (1) a separate second study (N = 50) comparing prospective digital strain versus post hoc analog-to-digital strain, and (2) in a third study (N = 95) comparing prospectively obtained TDI e' velocities with post hoc STE e' velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intra-observer agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post hoc STE to prospective digital STE for strain analysis. STE-derived e' velocities correlated with, but systematically underestimated, TDI e' velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β = -2.4 [95% CI -3.6, -1.2]% per 1-SD increase in fasting glucose; P echocardiography, the digitization and speckle tracking analysis of archival echocardiograms, is feasible and generates indices of cardiac mechanics similar to contemporary studies. © 2015, Wiley Periodicals, Inc.

  15. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  16. Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position

    Science.gov (United States)

    Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.

    2015-01-01

    Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063

  17. Multiple cardiac complications after adjuvant therapy for breast cancer: the importance of echocardiography. A case report and review of the literature.

    Science.gov (United States)

    Gurghean, Adriana Luminita; Savulescu-Fiedler, Ilinca; Mihailescu, Anca

    2017-01-31

    Cardiovascular complications induced by adjuvant cancer therapies may become symptomatic after many years, being responsible for increased morbidity and mortality in long-term survivors. We report a case of a 54-year old female admitted for severe heart failure induced by myocardial and valvular damage after postoperative adjuvant therapy for left breast cancer 6 years ago. Her recent history revealed nonST elevation myocardial infarction in the absence of significant cardiovascular risk factors. Transthoracic echocardiography, tissue Doppler imaging and speckle-tracking imaging revealed severe biventricular systolic dysfunction, severe mitral and tricuspid regurgitation and severe pulmonary hypertension.

  18. Laser Doppler imaging, thermographic imaging, and tissue oxygen saturation measurements detect early skin reactions during breast radiotherapy

    Science.gov (United States)

    Harrison, David K.; Harrison, Eileen M.; Newton, David J.; Windsor, Phyllis M.

    2001-05-01

    A range of acute skin reactions, ranging from mild erythema to moist desquamation, can be seen in patients receiving standard fractionated radiotherapy to the breast for conservation therapy of breast carcinoma. In a number of cases these reactions can cause considerable discomfort and seriously affect the patient's quality of life. In previous studies we have used the techniques of laser Doppler imaging, digital thermographic imaging and lightguide spectrophotometry to study oxygen supply and blood flow in inflammatory reactions induced experimentally in forearm skin. The present study is an attempt to use the same techniques to investigate whether any or all of them can detect changes in breast skin very early on in the course of radiotherapy treatment. A further aim of the longer term study is to investigate to what extent these early changes may be able to predict the occurrence later of severe acute or delayed reactions.

  19. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  20. Semiquantitative Evaluation of Extrasynovial Soft Tissue Inflammation in the Shoulders of Patients with Polymyalgia Rheumatica and Elderly-Onset Rheumatoid Arthritis by Power Doppler Ultrasound.

    Science.gov (United States)

    Suzuki, Takeshi; Yoshida, Ryochi; Okamoto, Akiko; Seri, Yu

    2017-01-01

    Objectives . To develop a scoring system for evaluating the extrasynovial soft tissue inflammation of the shoulders in patients with polymyalgia rheumatica (PMR) and elderly-onset rheumatoid arthritis with PMR-like onset (pm-EORA) using ultrasound. Methods . We analyzed stored power Doppler (PD) images obtained by the pretreatment examination of 15 PMR patients and 15 pm-EORA patients. A semiquantitative scoring system for evaluating the severity of PD signals adjacent to the anterior aspect of the subscapularis tendon was designed. Results . A four-point scale scoring for the hyperemia on the subscapularis tendon was proposed as follows in brief: 0 = absent or minimal flow, 1 = single vessel dots or short linear-shape signals, 2 = long linear-shape signals or short zone-shape signals, or 3 = long zone-shape signals. This scoring system showed good intra- and interobserver reliability and good correlation to quantitative pixel-counting evaluation. By using it, we demonstrated that inflammation in PMR is dominantly localized in extrasynovial soft tissue as compared with pm-EORA. Conclusions . We proposed a reliable semiquantitative scoring system using ultrasound for the evaluation of extrasynovial soft tissue inflammation of the shoulders in patients with both PMR and pm-EORA. This system is simple to use and can be utilized in future investigations.

  1. Stress echocardiography expert consensus statement

    NARCIS (Netherlands)

    R. Sicari (Rosa); P. Nihoyannopoulos (Petros); A. Evangelista (Arturo); J. Kasprzak (Jaroslav); P. Lancellotti (Patrizio); D. Poldermans (Don); J.U. Voigt; J.L. Zamorano (Jose)

    2008-01-01

    textabstractStress echocardiography is the combination of 2D echocardiography with a physical, pharmacological or electrical stress. The diagnostic end point for the detection of myocardial ischemia is the induction of a transient worsening in regional function during stress. Stress echocardiography

  2. Echocardiography in Ebstein's anomaly

    NARCIS (Netherlands)

    W.J. Gussenhoven (Wilhelmina Johanna)

    1984-01-01

    textabstractIn this thesis the value of echocardiography is evaluated for the diagnosis of Ebstein's anomaly of the tricuspid valve. This congenital heart defect, first described in 1866 by Wilhelm Ebstein, is characterized by an apical displacement of the septal and inferior tricuspid valve

  3. 3D Harmonic Echocardiography:

    NARCIS (Netherlands)

    M.M. Voormolen (Marco)

    2007-01-01

    textabstractThree dimensional (3D) echocardiography has recently developed from an experimental technique in the ’90 towards an imaging modality for the daily clinical practice. This dissertation describes the considerations, implementation, validation and clinical application of a unique

  4. Quantification in echocardiography

    NARCIS (Netherlands)

    Korsten, H.H.M.; Mischi, M.; Grouls, R.J.E.; Jansen, A.H.M.; Dantzig, van J.M.; Peels, C.H.

    2006-01-01

    Until recently, more than 2200 Swan Ganz catheters were used annually in the operating rooms (OR) and intensive care unit (ICU) of the Catharina Hospital in Eindhoven, The Netherlands. After cardiologists who were specialists in echocardiography (ECHO) trained anesthesiologists in ECHO, the need for

  5. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy.

    Science.gov (United States)

    Khan, Sitara G; Klettas, Dimitris; Kapetanakis, Stam; Monaghan, Mark J

    2016-03-01

    Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain) has conventionally been assessed using tissue Doppler imaging (TDI), which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference ('speckles') in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT. © 2016 The authors.

  6. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy

    Directory of Open Access Journals (Sweden)

    Sitara G Khan

    2016-05-01

    Full Text Available Cardiac resynchronisation therapy (CRT can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain has conventionally been assessed using tissue Doppler imaging (TDI, which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference (‘speckles’ in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT.

  7. Fetal Echocardiography and Indications

    Directory of Open Access Journals (Sweden)

    Melih Atahan Güven

    2008-09-01

    Full Text Available Congenital heart diseases are encountered in 0.8% of live births and are among the most frequently diagnosed malformations. At least half of these anomalies end up with death or require surgical interventions and are responsible for 30% of the perinatal mortality. Fetal echocardiography is the sum of knowledge, skill and orientation rather than knowing the embryologic details of the fetal heart. The purpose of fetal echocardiography is to document the presence of normal fetal cardiac anatomy and rhythm in high risk group and to define the anomaly and arrhythmia if present. A certain sequence should be followed during the evaluation of fetal heart. Sequential segmental analysis (SSA and basic definition terminology made it possible to determine a lot of complex cardiac anomalies during prenatal period. By the end of 1970’s, Shinebourne started using sequential segmental analysis for fetal cardiac evaluation and today, prenatal diagnosis of congenital heart disease is possible without any confusion. In this manner, whole fetal heart can be evaluated as the relation of three segments (atria, ventricles and the great arteries with each other, irrelevant of complexity of a possible cardiac anomaly. Presence of increased nuchal thickness during early gestation and abnormal four-chamber-view during ultrasonography by the obstetrician presents a clear indication for fetal echocardiography,however, one should keep in mind that 80-90% of the babies born with a congenital heart disease do not have a familial or maternal risk factor. In addition, it should be remembered that expectant mothers with diabetes mellitus pose an indication for fetal echocardiography.

  8. Imaging the heart: cardiac scintigraphy and echocardiography in US hospitals (1983)

    International Nuclear Information System (INIS)

    McPhee, S.J.; Garnick, D.W.

    1986-01-01

    The rapid growth of cardiac catheterization has raised questions about the availability of less costly, noninvasive tests such as cardiac scintigraphy and echocardiography. To assess their availability and rates of use, we surveyed 3778 non-federal short-term US hospitals in June, 1983. Overall, 2605 hospitals (69%) offered 201 Tl myocardial perfusion scans, 2580 (68%) 99mTc equilibrium gated blood pool scans, and 2483 (67%) cardiac shunt scans; 1679 hospitals (44%) offered M-mode and/or 2-dimensional echocardiography, and 768 (20%) pulsed Doppler echocardiography. Volumes of procedures varied enormously among hospitals capable of performing them. High volumes of both scintigraphy and echocardiography were performed in a small number of hospitals. Larger, voluntary, and teaching hospitals performed higher volumes of both procedures. Despite widespread availability of these noninvasive technologies, high volumes of both cardiac scintigraphy and echocardiography procedures are concentrated in a small number of US hospitals

  9. Detection of congenital heart disease by fetal echocardiography

    International Nuclear Information System (INIS)

    Fayyaz, A.; Majeed, S.M.I.

    2013-01-01

    Objective: The objective of the study was to determine the sensitivity, specificity, accuracy and predictive value of fetal echocardiography in our set up using postnatal echocardiography as gold standard. Study Design: Validation study. Place and Duration of study: This is an ongoing study in the Radiology department of CMH Rawalpindi and Armed Forces Institute of Cardiology (AFIC) Rawalpindi and the data collected from January 2007 to Jan 2012 is presented. Patients and Methods: Two hundred eighty seven patients reported for fetal echocardiography. Two hundred twenty nine patients were subsequently included in the study. These included patients of all ages who reported to the Radiology department of CMH Rawalpindi for fetal echocardiography. Fetal echo was done on Toshiba Aplio with 3.5 MHz probe having Doppler facility. Post natal evaluation was done by a pediatric cardiologist. Results: There were 207 (90.4%) true negative cases, 15 (6.6%) true positive, 2 (0.9%) false positive and 6 (2.2%) false negative cases. The sensitivity, specificity, positive and negative predictive values were 75%, 99%, 88%, 97% respectively. Conclusion: Fetal echocardiography has high specificity, negative predictive values and accuracy and cases diagnosed as normal can reassure the parents about the normal cardiac status of the fetus. (author)

  10. Early Detection of Subclinical Uremic Cardiomyopathy Using Two-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Hassanin, Noha; Alkemary, Alkhateeb

    2016-04-01

    Overhydration has a deleterious effect on cardio myocytes. This study was designated to evaluate left ventricular (LV) systolic and diastolic dysfunction in patients with various stages of chronic kidney disease (CKD) using conventional, tissue Doppler and two-dimensional speckle tracking echocardiography (2DSTE). Forty controls and 90 CKD patients, aged 49.3 ± 14 years old, were enrolled in the study. Patients were divided into 3 groups depending on their glomerular filtration rate. Group 1 (≥60 mL/min per 1.73 m(2) ), group 2 (≤60 mL/min per 1.73 m(2) ), and group 3 (≤60 mL/min per 1.73 m(2) and on regular dialysis for at least 12 months). Pulsed-Doppler and tissue Doppler studies were used to estimate LV filling pressure E/E'. Using 2DSTE, circumferential, radial, and longitudinal functions of the LV have been measured. LV longitudinal systolic strain, early, and late diastolic strain rates were significantly reduced in CKD patients (-16.9 ± 3.8%, 1.6 ± 0.5%, and 1.3 ± 0.4% in CKD vs. -22.5 ± 0.6%, 2.3 ± 0.2%, and 1.9 ± 0.1% in controls, P < 0.001 for all), and no difference was observed in terms of the circumferential LV functions (-22.4 ± 1.7 vs. -22.5 ± 1.4, P = 0.567). Severity of the kidney dysfunction appears to parallel with the rise of E/E' significantly (P < 0.001). In CKD, although the longitudinal and radial systolic functions were reduced, LV ejection fraction may remain within normal limits due to the preservation of the circumferential functions. Early detection of uremic cardiomyopathy might provide useful information for the risk stratification and decide the proper dialysis therapy in these patients. © 2015, Wiley Periodicals, Inc.

  11. Influence of detomidine on atrial fibrillation cycle length measured by intracardiac electrogram recording and by colour tissue Doppler imaging in horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G

    2016-01-01

    Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF

  12. Effect of preload alternations on a new Doppler echocardiographic index of combined systolic and diastolic performance

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Egstrup, K

    1999-01-01

    The objective of the study was to assess the effect of preload alternations on a nongeometric Doppler index of combined systolic and diastolic myocardial performance (MPI). Doppler echocardiography was performed during Valsalva maneuver, passive leg lifting, and after sublingual administration of...

  13. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  14. Measurement of left ventricular torsion using block-matching-based speckle tracking for two-dimensional echocardiography

    Science.gov (United States)

    Sun, Feng-Rong; Wang, Xiao-Jing; Wu, Qiang; Yao, Gui-Hua; Zhang, Yun

    2013-01-01

    Left ventricular (LV) torsion is a sensitive and global index of LV systolic and diastolic function, but how to noninvasively measure it is challenging. Two-dimensional echocardiography and the block-matching based speckle tracking method were used to measure LV torsion. Main advantages of the proposed method over the previous ones are summarized as follows: (1) The method is automatic, except for manually selecting some endocardium points on the end-diastolic frame in initialization step. (2) The diamond search strategy is applied, with a spatial smoothness constraint introduced into the sum of absolute differences matching criterion; and the reference frame during the search is determined adaptively. (3) The method is capable of removing abnormal measurement data automatically. The proposed method was validated against that using Doppler tissue imaging and some preliminary clinical experimental studies were presented to illustrate clinical values of the proposed method.

  15. The Evolutionary Development of Echocardiography

    Science.gov (United States)

    Maleki, Majid; Esmaeilzadeh, Maryam

    2012-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information on cardiac morphology, function, and hemodynamics. It is the most frequently used cardiovascular diagnostic test only after electrocardiography. In less than five decades, the evolution in this technique has made it the basic part of cardiovascular medicine. Herein, the evolution of various forms of echocardiography is briefly described. PMID:23390327

  16. Echocardiographic Assessment of Left Ventricular Function in Healthy Horses and in Horses with Heart Disease Using Pulsed-Wave Tissue Doppler Imaging.

    Science.gov (United States)

    Koenig, T R; Mitchell, K J; Schwarzwald, C C

    2017-03-01

    Assessment of left ventricular (LV) function by tissue Doppler imaging (TDI) is not well established in horses with heart disease. To describe the use of pulsed-wave (PW) TDI for the assessment of LV function, establish reference intervals, investigate effects of mitral regurgitation (MR), aortic regurgitation (AR), and primary myocardial disease (MD), and provide proof of concept for the use of PW TDI in Warmblood horses with heart disease. Thirty healthy horses, 38 horses with MR, 25 with AR, 8 with MD. Echocardiograms were retrospectively analyzed. Reference intervals were calculated. PW TDI indices of healthy horses and horses with MR, AR, and MD were compared by one-way ANOVA and Dunnett's test. A complete set of PW TDI variables could be obtained in 94 of 101 horses. Variables corresponding to isovolumic intervals were most difficult to measure. Valvular regurgitation influenced variables describing isovolumic contraction and ejection. Horses with MD had significantly shortened ET m (-118.5 [-154.1 to -82.9] ms; mean difference [95% CI of difference of means]), increased PEP m /ET m (0.11 [0.05 to 0.17]), prolonged IMP m (0.28 [0.18 to 0.37]), increased S 1 (8.9 [5.2 to 12.6] cm/s), and decreased E 1 (-2.6 [-4.7 to -0.5] cm/s), E m (-14.2 [-19.9 to -8.5] cm/s), and E m /A m ratio (-1.6 [-2.6 to -0.6]). Pulsed-wave TDI might be useful for detection of LV dysfunction in horses with primary MD. The clinical value of TDI in horses with MR and AR remains uncertain. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. A brief history of fetal echocardiography and its impact on the management of congenital heart disease.

    Science.gov (United States)

    Maulik, Dev; Nanda, Navin C; Maulik, Devika; Vilchez, Gustavo

    2017-12-01

    Congenital heart disease (CHD), the most common congenital malformation, is associated with adverse outcome. Development of fetal echocardiography has made prenatal diagnosis of CHD a reality, and in the process revolutionized its management. This historical review briefly narrates this development over the decades focusing on the emergence of the primary modalities of fetal echocardiography comprised of the time-motion mode, two-dimensional B-mode, spectral Doppler, color Doppler, and three- and four-dimensional cardiac imaging. Collaboration between clinicians and engineers has been central to these advances. Also discussed are the accuracy and impact of fetal echocardiography on the management of CHD, and especially its role in the prenatal diagnosis of critical CHD in individualizing the management and improving the outcome. Despite these advances, most cases of CHD are not identified prenatally, emphasizing the continuing need for further technological and educational innovation and improvement. © 2017, Wiley Periodicals, Inc.

  18. Variações de parâmetros da função diastólica do ventrículo esquerdo de acordo com a idade através da ecocardiografia com Doppler tissular Changes in the parameters of left ventricular diastolic function according to age on tissue Doppler imaging

    Directory of Open Access Journals (Sweden)

    Márcia Duarte Pedone

    2004-12-01

    Full Text Available OBJETIVO: Determinar a correlação entre as velocidades diastólicas do Doppler tissular com a idade em amostra de adultos saudáveis, e correlacionar a idade com as velocidades do fluxo transmitral e de veias pulmonares. MÉTODOS: Estudados, através da ecocardiografia, 51 indivíduos saudáveis, com idades entre 21 e 69 anos e registradas as velocidades miocárdicas diastólicas ao Doppler tissular e determinadas as velocidades dos fluxos transmitral e venoso pulmonar. RESULTADOS: As velocidades miocárdicas diastólicas iniciais septal basal e lateral basal apresentaram correlação inversa com a idade, com r = - 0,40 (p = 0,004 e r = - 0,60 (p = 0,0001 respectivamente. As velocidades atriogênicas do Doppler tissular foram diretamente correlacionadas com a idade, sendo no segmento septal basal r = 0,56 (p = 0,0001 e no segmento lateral basal r = 0,50 (p = 0,0001. As velocidades do fluxo transmitral e do fluxo venoso pulmonar também mostraram correlação com a idade. CONCLUSÃO: Existe correlação entre a idade e as velocidades miocárdicas diastólicas do Doppler tissular e com as velocidades do fluxo transmitral e fluxo venoso pulmonar, demonstrando em indivíduos saudáveis uma variação de parâmetros da função diastólica do ventrículo esquerdo com a evolução natural da idade.OBJECTIVE: To determine the correlation between diastolic velocities on tissue Doppler imaging and age in a sample of healthy adults and to correlate age with the velocities of transmitral and pulmonary vein flows. METHODS: Echocardiographic assessment of 51 healthy individuals, whose ages ranged from 21 to 69 years. The diastolic myocardial velocities were recorded on tissue Doppler imaging. The velocities of the transmitral and pulmonary vein flows were also determined. RESULTS: The initial basal septal and basal lateral diastolic myocardial velocities showed an inverse correlation with age [r = - 0.40 (P = 0.004, and r = - 0.60 (P = 0.0001, respectively

  19. Echocardiography in Arterial Hypertension.

    Science.gov (United States)

    de Simone, Giovanni; Mancusi, Costantino; Esposito, Roberta; De Luca, Nicola; Galderisi, Maurizio

    2018-05-02

    Hypertension is a condition characterized by pressure and/or volume overloads and echocardiography is helpful and feasible to understand hemodynamic mechanisms. Echocardiographic information is sometimes critical and susceptible of modifying decision making. In this review, we provide detailed descriptions of the parameters that can be derived from a standard transthoracic echocardiogram, including some more recent techniques. We will also explain how each parameter might have impact in the evaluation of the hypertensive patient and give indications on when to refer patients to echo-labs, which parameters are critical and which ones might be redundant, and how to use the information obtained in the report. Cardiac geometry, LV systolic and diastolic function, LV pump performance, output impedance and left atrial function are parameters that might be altered in arterial hypertension, but not necessarily doctors need the whole information for decision making. The critical measures are provided.

  20. The Doppler paradox.

    Science.gov (United States)

    Ntalas, Ioannis; Karády, Júlia; Kapetanakis, Stam; Rajani, Ronak

    2017-12-01

    Obstructive prosthetic valve thrombosis (PVT) is a rare but severe complication that usually occurs in the presence of suboptimal anticoagulation. Although fluoroscopy is commonly used to detect abnormal leaflet motion as a surrogate marker for PVT, its inability to directly visualize adjacent tissue and valve physiology leaves it susceptible to miss clinically important PVT. In this manuscript, we report the case of a 54-year-old woman with a mechanical mitral valve who was admitted to our institute with exertional dyspnea. Although valve fluoroscopy was normal, subsequent 3D echocardiography and ECG-gated multiphase computed tomography confirmed the presence of PVT that was subsequently treated successfully with surgical replacement. Our case demonstrates the utility of multimodality imaging in establishing PVT in patients with abnormal prosthetic valve physiology and progressive symptoms. © 2017, Wiley Periodicals, Inc.

  1. Right Ventricular Doppler Echocardiographic Study of Indeterminate Form of Chagas Disease

    Directory of Open Access Journals (Sweden)

    Rogério Gomes Furtado

    2015-03-01

    Full Text Available Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D, 92 patients were assessed and divided into two groups: group I (normal, n = 31 and group II (ICD/CN, n = 61. Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%, mobility of the tricuspid annulus (0.0% versus 0.0%, and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016. The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099 and pulsed Doppler (61.3% versus 68%, p = 0.141 and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%, pseudonormal pattern (0.0% versus 0.0%, and restrictive pattern (0.0% versus 0.0% was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables, suggesting incipient changes in RV systolic function in the ICD/CN group.

  2. Pacing stress echocardiography

    Directory of Open Access Journals (Sweden)

    Agrusta Marco

    2005-12-01

    Full Text Available Abstract Background High-rate pacing is a valid stress test to be used in conjunction with echocardiography; it is independent of physical exercise and does not require drug administration. There are two main applications of pacing stress in the echo lab: the noninvasive detection of coronary artery disease through induction of a regional transient dysfunction; and the assessment of contractile reserve through peak systolic pressure/ end-systolic volume relationship at increasing heart rates to assess global left ventricular contractility. Methods The pathophysiologic rationale of pacing stress for noninvasive detection of coronary artery disease is obvious, with the stress determined by a controlled increase in heart rate, which is a major determinant of myocardial oxygen demand, and thereby tachycardia may exceed a fixed coronary flow reserve in the presence of hemodynamically significant coronary artery disease. The use of pacing stress echo to assess left ventricular contractile reserve is less established, but promising. Positive inotropic interventions are mirrored by smaller end-systolic volumes and higher end-systolic pressures. An increased heart rate progressively increases the force of ventricular contraction (Bowditch treppe or staircase phenomenon. To build the force-frequency relationship, the force is determined at different heart rate steps as the ratio of the systolic pressure (cuff sphygmomanometer/end-systolic volume index (biplane Simpson rule. The heart rate is determined from ECG. Conclusion Two-dimensional echocardiography during pacing is a useful tool in the detection of coronary artery disease. Because of its safety and ease of repeatability noninvasive pacing stress echo can be the first-line stress test in patients with permanent pacemaker. The force-frequency can be defined as up- sloping (normal when the peak stress pacing systolic pressure/end-systolic volume index is higher than baseline and intermediate stress

  3. Clinical applications of contrast echocardiography

    International Nuclear Information System (INIS)

    Jorge, Leon Galindo

    2005-01-01

    The echocardiography is the technique more used for the diagnosis and pursuit of the cardiovascular illnesses; therefore, their diagnostic precision has acquired a vital importance in the handling of the patients with cardiovascular pathologies. However, with relative frequency, the diagnostic capacity of the echocardiography exam is diminished by limitations of the acoustic window, mainly in-patient with obesity, lung illnesses and alterations of the thoracic wall. This can be obviated with the use of the intra-esophagus echocardiography, although this it is a procedure semi-invasive and not very practical of carrying out in all the patients with problems of acoustic window. In this article the clinical applications are revised more common of the contrast echocardiography

  4. Carcinoid syndrome diagnosed by echocardiography.

    Science.gov (United States)

    Garg, Scot; Bourantas, Christos V; Nair, Rajesh K; Alamgir, Farqad

    2011-02-17

    Right heart failure is a common presentation to both general physicians and cardiologists. Echocardiography is a useful investigation, and usually imaging of the liver is confined to helping estimate the right atrial pressure. We report a case of right heart failure where incidental imaging of the liver architecture during transoesophageal echocardiography helped in establishing the final diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  5. Three-dimensional transesophageal echocardiography: Principles and clinical applications

    Directory of Open Access Journals (Sweden)

    Annette Vegas

    2016-01-01

    Full Text Available A basic understanding of evolving 3D technology enables the echocardiographer to master the new skills necessary to acquire, manipulate, and interpret 3D datasets. Single button activation of specific 3D imaging modes for both TEE and transthoracic echocardiography (TTE matrix array probes include (a live, (b zoom, (c full volume (FV, and (d color Doppler FV. Evaluation of regional LV wall motion by RT 3D TEE is based on a change in LV chamber subvolume over time from altered segmental myocardial contractility. Unlike standard 2D TEE, there is no direct measurement of myocardial thickening or displacement of individual segments.

  6. Instrumentation for contrast echocardiography: technology and techniques.

    Science.gov (United States)

    Kaul, Sanjiv

    2002-11-18

    Contrast echocardiography is the only clinical imaging technique in which the imaging modality (ultrasound) can cause a change in the contrast agent (microbubbles). The change in the contrast agent can range from small oscillations of the microbubbles at a low mechanical index to their disruption at a high mechanical index. The specific mechanical index required to produce these various effects may be different for each contrast agent, depending on the bubble dimension as well as shell and gas characteristics. These alterations in bubbles result in changes in ultrasound backscatter that are specific for the bubbles themselves, rather than for tissue, and are therefore exploited for imaging their presence in tissue. These signal-processing techniques have resulted in an increased signal-to-noise ratio from bubbles vis-à-vis the tissue and have made online assessment of myocardial perfusion possible.

  7. Concordance and reproducibility between M-mode, tissue Doppler imaging, and two-dimensional strain imaging in the assessment of mitral annular displacement and velocity in patients with various heart conditions

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sorensen, Tor; Sogaard, Peter

    2014-01-01

    AIMS: Mitral annular (MA) displacement reflects longitudinal left ventricular (LV) deformation and systolic velocity measurements reflect the rate of contraction; both are valuable in the diagnosis and prognosis of cardiac disease. The aim of this study was to test the agreement and reproducibility...... between motion mode (M-mode), colour tissue Doppler imaging (TDI), and two-dimensional strain imaging (2DSI) when measuring MA displacement and systolic velocity. METHODS AND RESULTS: Using GE Healthcare Vivid 7 and E9 and Echopac BT11 software, MA displacement and velocity measurements by 2DSI, TDI...

  8. Doppler Tissue Imaging Is an Independent Predictor of Outcome in Patients with ST-Segment Elevation Myocardial Infarction Treated with Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Jensen, Jan Skov; Pedersen, Sune

    2014-01-01

    in patients treated with primary percutaneous coronary intervention. METHOD: In total, 391 patients who were admitted with STEMIs and treated with primary percutaneous coronary intervention were prospectively included. All participants were examined by echocardiography 2 days (interquartile range, 1-3 days......) after STEMI. Longitudinal systolic (s'), early diastolic (e'), and late diastolic (a') myocardial velocities were measured using color DTI at six mitral annular sites and averaged to provide global estimates. RESULTS: The median follow-up period was 25 months (interquartile range, 19-32 months...

  9. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  10. Ergotamine-derived dopamine agonists and left ventricular function in Parkinson patients: systolic and diastolic function studied by conventional echocardiography, tissue Doppler imaging, and two-dimensional speckle tracking.

    Science.gov (United States)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, Erik; Ostergaard, Karen; Safikhany, Gholamhossein; Egeblad, Henrik

    2008-11-01

    Ergot-derived dopamine agonists (EDDA) induce fibrotic heart valve disease. We aimed to investigate whether EDDA treatment also affects left ventricular (LV) function. Myocardial function was evaluated in 110 Parkinson patients [mean age (63.4 +/- 9.0 years)] treated for at least 6 months with either EDDA (n = 71) or non-EDDA (n = 39). LV ejection fraction did not differ between EDDA and non-EDDA patients [63 +/- 4% vs. 65 +/- 4% (ns)]. There was no difference in prevalence of diastolic dysfunction between EDDA and non-EDDA patients [7% vs. 8% (ns)]. Finally, averaged LV systolic myocardial strain and longitudinal displacement analysed by means of two-dimensional speckle tracking showed no difference between EDDA and non-EDDA patients [strain: 19 +/- 3% vs. 19 +/- 2% (ns) and longitudinal displacement: 12 +/- 2 mm vs. 12 +/- 2 mm (ns)]. Elevated p-NT-proBNP was found in 38% of EDDA patients and in 59% of non-EDDA patients (ns). In contrast to the well-established association between EDDA treatment and valvular fibrosis, EDDA did not have a detectable adverse impact on myocardial systolic and diastolic function.

  11. Archeological Echocardiography: Digitization and Speckle-Tracking Analysis of Archival Echocardiograms in the HyperGEN Study

    Science.gov (United States)

    Aguilar, Frank G.; Selvaraj, Senthil; Martinez, Eva E.; Katz, Daniel H.; Beussink, Lauren; Kim, Kwang-Youn A.; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R.; Arnett, Donna K.; Shah, Sanjiv J.

    2015-01-01

    Background Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle-tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. Methods In the NHLBI HyperGEN study (N=2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter/intraobserver agreement was calculated. Accuracy was evaluated in (1) a separate second study (N=50) comparing prospective digital strain vs. post-hoc analog-to-digital strain; and (2) in a third study (N=95) comparing prospectively-obtained TDI e′ velocities with post-hoc STE e′ velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Results Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intraobserver agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post-hoc STE to prospective digital STE for strain analysis. STE-derived e′ velocities correlated with, but systematically underestimated, TDI e′ velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β =−2.4 [95% CI −3.6,−1.2]% per 1-SD increase in fasting glucose; Pechocardiography, the digitization and speckle-tracking analysis of archival echocardiograms, is feasible and generates parameters of cardiac mechanics similar to contemporary studies. PMID

  12. Feasibility of transesophageal echocardiography in birds without cardiac disease.

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Nevarez, Javier G; Tully, Thomas N

    2010-03-01

    To establish a technique of transesophageal echocardiography (TEE) in birds without cardiac disease and describe the imaging planes obtained. Validation study. 18 birds including 3 pigeons (Columbia livia), 3 barred owls (Strix varia), 2 red-tailed hawks (Buteo jamaicensis), 1 goose (Anser anser), 1 mallard duck (Anas platyrhynchos), 1 Muscovy duck (Cairina moschata), 2 brown pelicans (Pelecanus occidentalis), 2 Hispaniolan Amazon parrots (Amazona ventralis), 2 red-fronted macaws (Ara rubrogenys), and 1 military macaw (Ara militaris). For each bird, anesthesia was induced and maintained by use of isoflurane. A pediatric, multiplane transesophageal ultrasound probe was passed into the esophagus and adjusted to the level of the heart for echocardiography. Probe positions were recorded via fluoroscopy, and associated imaging planes were described. TEE was performed successfully in all birds except the pelicans, 1 Hispaniolan Amazon parrot, and the red-fronted macaws. Five imaging planes of the heart were consistently viewed from 3 positions of the probe (identified as caudal, middle, and cranial positions relative to the cardiac silhouette). M-mode echocardiography of the left ventricle and the aortic root was performed. Color flow and spectral Doppler ultrasonographic images of in- and outflow regions were obtained. One Hispaniolan Amazon parrot died as a result of esophageal perforation. TEE examination of birds was feasible and provided a larger number of imaging planes with better resolution and details than those typically achieved via a transcoelomic approach. However, TEE should be performed with caution in psittacines.

  13. Echocardiography in chronic liver disease: systematic review.

    Science.gov (United States)

    Mota, Vitor Gomes; Markman Filho, Brivaldo

    2013-04-01

    Doppler echocardiography (Echo) is a non-invasive method of excellent accuracy to screen portopulmonary hypertension (PPH) and to assess intrapulmonary shunts (IPS) in chronic liver disease (CLD). In the past decade, Echo proved to play a fundamental role in the diagnosis of cirrhotic cardiomyopathy (CCM). To perform a systematic review of relevant articles on the subject 'Echo in CLD'. In November 2011, a systematic review was performed in the PubMed, LILACS and SciELO databases, and the characteristics of the studies selected were reported. The search based on descriptors and free terms obtained 204 articles (179 in Pubmed, 21 in LILACS, and 1 in SciELO). Of those 204 articles, 22 were selected for systematic review. A meta-analysis could not be performed because of the heterogeneity of the articles. Echo should be part of CLD stratification for screening PPH, IPS and CCM, because, most of the time, such complications are diagnosed only when patients are already waiting for a liver transplant.

  14. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  15. Fetal Echocardiography/Your Unborn Baby's Heart

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Fetal Echocardiography / Your Unborn Baby's Heart Updated:Oct 6,2016 ... Your Risk • Symptoms & Diagnosis Introduction Common Tests Fetal Echocardiography/Your Unborn Baby's Heart - Fetal Echocardiogram Test - Detection ...

  16. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  17. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    Science.gov (United States)

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  18. Role of echocardiography in the evaluation of syncope: a prospective study

    Science.gov (United States)

    Sarasin, F P; Junod, A-F; Carballo, D; Slama, S; Unger, P-F; Louis-Simonet, M

    2002-01-01

    Objective: To study the role of echocardiography in the stepwise evaluation of syncope. Design: A prospective observational study with an 18 month follow up. Setting: University teaching hospital providing primary and tertiary care. Subjects: 650 consecutive patients with syncope and clinical suspicion of an obstructive valvar lesion, or with syncope not explained by history, physical examination, or a 12 lead ECG, who underwent bidimensional Doppler transthoracic echocardiography. Main outcome measures: The causes of syncope were assigned using published diagnostic criteria. Echocardiography was considered diagnostic when confirming a suspected diagnosis, or when revealing occult cardiac disease explaining the syncope. Results: A systolic murmur was identified in 61 of the 650 patients (9%). Severe aortic stenosis was suspected in 20 of these and was confirmed by echocardiography in eight. Follow up excluded further cases of aortic stenosis. In patients with unexplained syncope (n = 155), routine echocardiography showed no abnormalities that established the cause of the syncope. Echocardiography was normal or non-relevant in all patients with a negative cardiac history and a normal ECG (n = 67). In patients with a positive cardiac history or an abnormal ECG (n = 88), echocardiography showed systolic dysfunction (left ventricular ejection fraction ≤ 40%) in 24 (27%) and minor non-relevant findings in the remaining 64. Arrhythmias were diagnosed in 12 of the 24 patients with systolic dysfunction (50%), and in 12 of the 64 remaining patients (19%) (p < 0.01). Conclusions: Echocardiography was most useful for assessing the severity of the underlying cardiac disease and for risk stratification in patients with unexplained syncope but with a positive cardiac history or an abnormal ECG. PMID:12231593

  19. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  20. Ekhokardiografi Endokardiosis Penyakit Katup Mitral Jantung Anjing (ECHOCARDIOGRAPHY OF ENDOCARDIOSIS MITRAL VALVE HEART DISEASE IN DOGS

    Directory of Open Access Journals (Sweden)

    Deni Noviana

    2013-08-01

    Full Text Available Endocardiosis is a disease commonly found in Pomeranian dog characterized by progressive myxomatousdegeneration of the atrio-ventricular valves especially in the mitral valve. The purpose of this study was todefine the diagnose and severeity of this disease on the Pomeranian by using brightness mode, motion mode,dan color flow Doppler echocardiography technique. Echocardiography was performed on 8 Pomeranianconsisting of 6 males and 2 females with age range of 2-14 years. Brightness mode echocardiography wasused to see the echotexture of endocardium, mitral valve, and the valve movement. The results showedendocardium thickening, along with chronic fibrosis and nodular thickening of the anterior and posteriormitral valve leaflet. Three out of seven cases showed prolapsed of the mitral valve. Motion modeechocardiography was performed in order to measure left ventricle internal dimension, myocardium thickness,fractional shortening, left atrial and aortic dimension. The results showed myocardium thickening, alongwith left atrial enlargement. Color flow Doppler echocardiography was used to confirm the mitral valveregurgitation. Three of seven cases showed the presence of regurgitation signed by turbulence color of theprolapsed mitral valve. Based on the degree of severity, scoring system used in this study, endocardiosis canbe divided into three types that are mild, moderate and severe.

  1. Usefulness of three-dimensional echocardiography in the assessment of valvular involvement in Loeffler endocarditis.

    Science.gov (United States)

    Hernandez, Carlos M; Arisha, Mohammed J; Ahmad, Amier; Oates, Ethan; Nanda, Navin C; Nanda, Anil; Wasan, Anita; Caleti, Beda E; Bernal, Cinthia L P; Gallardo, Sergio M

    2017-07-01

    Loeffler endocarditis is a complication of hypereosinophilic syndrome resulting from eosinophilic infiltration of heart tissue. We report a case of Loeffler endocarditis in which three-dimensional transthoracic and transesophageal echocardiography provided additional information to what was found by two-dimensional transthoracic echocardiography alone. Our case illustrates the usefulness of combined two- and three-dimensional echocardiography in the assessment of Loeffler endocarditis. In addition, a summary of the features of hypereosinophilic syndrome and Loeffler endocarditis is provided in tabular form. © 2017, Wiley Periodicals, Inc.

  2. Echocardiography in the flight program

    Science.gov (United States)

    Charles, John B.; Bungo, Michael W.; Mulvagh, Sharon L.

    1991-01-01

    Observations on American and Soviet astronauts have documented the association of changes in cardiovascular function during orthostasis with space flight. A basic understanding of the cardiovascular changes occurring in astronauts requires the determination of cardiac output and total peripheral vascular resistance as a minimum. In 1982, we selected ultrasound echocardiography as our means of acquiring this information. Ultrasound offers a quick, non-invasive and accurate means of determining stroke volume which, when combined with the blood pressure and heart rate measurements of the stand test, allows calculation of changes in peripheral vascular resistance, the body's major response to orthostatic stress. The history of echocardiography in the Space Shuttle Program is discussed and the results are briefly presented.

  3. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  4. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  5. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  6. Changes in cardiac function and structure in newly diagnosed Graves' disease. A conventional and 2D-speckle tracking echocardiography study.

    Science.gov (United States)

    Aroditis, K; Pikilidou, M; Vourvouri, E; Hadjistavri, L; Zebekakis, P; Yovos, J; Efthimiadis, G; Karvounis, H

    2017-02-01

    Overproduction of thyroid hormones leads to structural as well as functional cardiac changes. Conventional echocardiography but also recently developed sophisticated two-dimensional echocardiography speckle (2D-STE) tracking allow elaborate evaluation of these changes. Our purpose was to investigate the effects of thyroid hormones overproduction on the heart in patients with Graves' disease and changes that occur after 6 months thyrostatic therapy. We conducted a prospective, case-control study of 6 months duration. Full echocardiographic assessment at diagnosis and after 6 months of thyrostatic therapy were performed in 44 patients with Graves' disease, aged 37.6 ± 9.1 years. Additionally, 43 euthyroid controls were studied for the same time period. Left ventricular end diastolic diameter (LVEDD) and left ventricular end systolic diameter (LVESD) were higher in the patient group while triscupid annular plane systolic excursion (TAPSE) was lower in the patient group. Moreover, left ventricular (LV) mass index and left atrium (LA) volume index were higher in the Graves' disease group. Diastolic impairment as assessed with conventional echocardiography including tissue Doppler was present in the patient group (E/A ratio 0.87 ± 0.10,). 2D-STE analysis, revealed an increase in the strain rate at the isovolumic relaxation time (SRIVRT, 0.310 ± 0.07 patients versus 0.298 ± 0.09 s -1 controls). Improvement in diastolic and right systolic function as well as in left ventricular structural parameters was observed after restoration of euthyroidism (E/A ratio from 0.87 ± 0.10 versus 0.9 ± 0.08, p < 0.05). Patients with newly diagnosed Graves' showed an improvement in diastolic function, right systolic function and structural parameters after 6 months of thyrostatic treatment.

  7. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  8. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  9. Echocardiography-guided or "sided" pericardiocentesis.

    Science.gov (United States)

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  10. Left Ventricular Myocardial Deformation Parameters Are Affected by Coronary Slow Flow Phenomenon: A Study of Speckle Tracking Echocardiography.

    Science.gov (United States)

    Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut

    2016-05-01

    The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015

  11. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  12. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  13. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  14. Role of modern 3D echocardiography in valvular heart disease

    Science.gov (United States)

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  15. Healed perivalvular abscess: Incidental finding on transthoracic echocardiography

    Directory of Open Access Journals (Sweden)

    Vishnu Datt

    2014-01-01

    Full Text Available A 36-year-old male patient presented with the complaints of palpitations and breathlessness. Preoperative transthoracic echocardiography (TTE revealed a bicuspid aortic valve; severe aortic regurgitation with dilated left ventricle (LV and mild LV systolic dysfunction (ejection fraction 50%. He was scheduled to undergo aortic valve replacement. History was not suggestive of infective endocarditis (IE. Preoperative TTE did not demonstrate any aortic perivalvular abscess. Intraoperative transesophageal echocardiography (TEE examination using the mid-esophageal (ME long-axis view, showed an abscess cavity affecting the aortic valve, which initially was assumed to be a dissection flap, but later confirmed to be an abscess cavity by color Doppler examination. The ME aortic valve short-axis view showed two abscesses; one was at the junction of the non-coronary and left coronary commissure and the other one above the right coronary cusp. Intraoperatively, these findings were confirmed by the surgeons. The case report demonstrates the superiority of TEE over TTE in diagnosing perivalvular abscesses.

  16. [Real time 3D echocardiography

    Science.gov (United States)

    Bauer, F.; Shiota, T.; Thomas, J. D.

    2001-01-01

    Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.

  17. Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography

    NARCIS (Netherlands)

    Salustri, A.; Becker, A. E.; van Herwerden, L.; Vletter, W. B.; ten Cate, F. J.; Roelandt, J. R.

    1996-01-01

    This study was done to ascertain whether three-dimensional echocardiography can facilitate the diagnosis of mitral valve abnormalities. The value of the additional information provided by three-dimensional echocardiography compared with two-dimensional multiplane transesophageal echocardiography for

  18. Transesophageal echocardiography in NeoChord procedure

    Directory of Open Access Journals (Sweden)

    Pittarello Demetrio

    2015-01-01

    Full Text Available Background: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. Methods: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment , for the final tensioning of the chordae and for the final evaluation of the surgical result. Result and Conclusion: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.

  19. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  20. Abnormal myocardial capillary density in apical hypertrophic cardiomyopathy can be assessed by myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Moon, Jeonggeun; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Jang, Yangsoo; Chung, Namsik; Rim, Se-Joong

    2010-01-01

    Myocardial ischemia and dysfunction can occur in hypertrophic cardiomyopathy (HCM) because of the high muscle-to-blood ratio, even without significant coronary artery disease. Microbubbles reside only in the intravascular space and myocardial video-intensity during systole results mostly from microbubbles within capillaries. The hypothesis explored in the present study was that an abnormal capillary density in apical HCM (ApHCM) can be demonstrated using myocardial contrast echocardiography (MCE). The 56 patients were investigated (31 males, age 58±9 years; 33 ApHCM, 9 hypertensive left ventricular hypertrophy [LVH], 14 controls). MCE was performed with low-mechanical-index power modulation imaging. Tissue Doppler imaging to assess myocardial contractile function was obtained at the mitral annulus (S'), and 99m Tc-MIBI single photon emission computed tomography (SPECT) was also performed. All ApHCM patients exhibited perfusion defects at the hypertrophied segments in the systolic phase during MCE, whereas SPECT showed normal or rather increased perfusion at those sites. The cyclic variation of video-intensity was exaggerated in ApHCM when compared with the LVH or control group (% of [systolic video-intensity]/[diastolic video-intensity]: 33.0±12.3%, 88.3±19.2% and 79.4±13.9%, respectively [P<0.05]). Concurrently, MCE cyclic variation and perfusion defect size were related to decreased S' (P<0.05 for all). A perfusion defect at the hypertrophied segment, representing abnormal myocardial capillary density, was observed in ApHCM patients during MCE. The extent of MCE cyclic variation and the perfusion defect size both correlate with decreased myocardial contractile property in ApHCM. (author)

  1. A quantitative analysis of microcirculation in sore-prone pressure areas on conventional and pressure relief hospital mattresses using laser Doppler flowmetry and tissue spectrophotometry.

    Science.gov (United States)

    Rothenberger, Jens; Krauss, Sabrina; Held, Manuel; Bender, Dominik; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Constantinescu, Mihai Adrian; Jaminet, Patrick

    2014-11-01

    Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  2. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Science.gov (United States)

    Bull, Sacha; Newton, James

    2017-01-01

    Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities. PMID:28096184

  3. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Directory of Open Access Journals (Sweden)

    Malgorzata Wamil MD PhD

    2017-03-01

    Full Text Available Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities.

  4. OPPORTUNITIES OF TRANSVAGINAL ECHOCARDIOGRAPHY FOR EARLY PRENATAL DIAGNOSIS OF INBORN HEART DISEASES IN FETUS

    Directory of Open Access Journals (Sweden)

    E.A. Shevchenko

    2008-01-01

    Full Text Available According to the literature data, transvaginal echocardiography (Echocg is the method, used for the doppler diagnostics in early terms of pregnancy (if principles of safety are observed. This method allows detecting about 70–97% of all prognostic cally significant inborn heart diseases in fetus, beginning at 12 week of pregnancy. a scheme of research includes estimation of four chamber cut of fetus heart, and study of state of its main arteries. This is an expert investigation, because it needs special grounding of specialist, high resolution ultrasonic equipment, and considerable expense of time. Wile parameters are estimated, it is necessary to use normative rates of sizes of ventricles and main arteries of fetus, developed by Russian experts, taking into account individual variations.Key words: transvaginal echocardiography, diagnosis, inborn heart disease.

  5. Comparative study between MRI and echocardiography in noncompaction of ventricular myocardium

    International Nuclear Information System (INIS)

    Sun Ziyan; Xia Liming; Wang Chengyuan; Rao Jingjing; Shenyu Weihui

    2007-01-01

    Objective: To investigate the MRI and echocardiography manifestations of noncompaction of ventricular myocardium(NVM) and assess the role of MR1 in the diagnosis of NVM by comparing it with echocardiography. Methods: Fourteen cases of NVM diagnosed by echocardiography were examined with MRI, including scanning of black-blood sequences, double inversion recovery fast spin echo (DIBFSE) and triple inversion recovery fast spin echo (TIRFSE), and white blood sequence: fast imaging employ steady state acquisition (FIESTA). Scanning plane includes short axis view, four-chamber view and long axis view. Results: Both MRI and echocardiography displayed involvement of left ventricles in thirteen cases and involvement of double ventricles in one case. Apexes of heart and the intermedius are commonly affected. MRI showed 54 segments and echocardiography showed 53 segments affected, and there is no significant difference between the capability of MRI and echocardiography (P=1,000). The affected myocardium consisted of two layers: subendocardial noncompacted myocardium and epicardial compacted myocardium, and the ratio measurement of N/C by MRI was 3.37±0.89 and it was 3.19±0.82 by echocardiography. Noncompacted myocardium was characterized by prominent and excessive myocardial trabeculations and deep intratrabecular recesses, in which the blood flow was communicated with the ventricle. One case was complicated with ventricular aneurysm, and coronary arteriography was performed with unremarkable findings. One case underwent heart transplantation because of progressive heart failure, Gross findings demonstrated prominent muscular' trabeculations with deep intratrabecular recesses, which coincided well with MRI findings. Conclusion: The MRI manifestation of NVM is characteristic, and MRI with multiple series and planes is helpful in the diagnose of NVM. Compared with echocardiography, MRI could display the pathological cardiac muscle more clearly, because of its high soft-tissue

  6. Preload dependence of color M-mode Doppler flow propagation velocity in controls and in patients with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Søndergaard, E

    2000-01-01

    The purpose of this study was to assess the effects of preload alterations on color M-mode flow propagation velocity (Vp) in volunteers with normal left ventricular (LV) function and in patients with depressed LV function. Color M-mode Doppler echocardiography was performed during Valsalva maneuv...

  7. Transesophageal echocardiography. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lambertz, Heinz; Lethen, Harald

    2013-01-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  8. Diagnostic value of echocardiography in infective endocarditis

    International Nuclear Information System (INIS)

    Luo Yinli; Ni Xianda; Hu Yuanping; Liu Jingyun; Yang Weiyu

    2010-01-01

    Objective: To investigate the feature and value of echocardiography for diagnosing infective endocarditis. Methods: The shape, size, echogenicity, distribution of vegetations and valvular injury of the heart were observed in 30 patients with infective endocarditis. Results: The vegetations were located in the aortic valves (10 cases), bicuspid valves (5), tricuspid valve (1), pulmonary valve (2), main pulmonary artery with patent ductus arteriosus (2), and right ventricle with ventricular septal defect (2). The size of vegetation ranged from 2 to 27 mm and the echogenicity of vegetations was low to high. The location, size, shape and amount of vegetations observed on echocardiography correlated well with the operative findings. Echocardiography also demonstrated underlying heart disease and abnormal hemodynamics induced by infective endocarditis. Conclusion: Echocardiography can determine the location, size, shape, amount of vegetation and concomitant cardiac disease in patients with infective endocarditis. It play an important role in treatment and prognosis. (authors)

  9. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  10. Tissue

    Directory of Open Access Journals (Sweden)

    David Morrissey

    2012-01-01

    Full Text Available Purpose. In vivo gene therapy directed at tissues of mesenchymal origin could potentially augment healing. We aimed to assess the duration and magnitude of transene expression in vivo in mice and ex vivo in human tissues. Methods. Using bioluminescence imaging, plasmid and adenoviral vector-based transgene expression in murine quadriceps in vivo was examined. Temporal control was assessed using a doxycycline-inducible system. An ex vivo model was developed and optimised using murine tissue, and applied in ex vivo human tissue. Results. In vivo plasmid-based transgene expression did not silence in murine muscle, unlike in liver. Although maximum luciferase expression was higher in muscle with adenoviral delivery compared with plasmid, expression reduced over time. The inducible promoter cassette successfully regulated gene expression with maximum levels a factor of 11 greater than baseline. Expression was re-induced to a similar level on a temporal basis. Luciferase expression was readily detected ex vivo in human muscle and tendon. Conclusions. Plasmid constructs resulted in long-term in vivo gene expression in skeletal muscle, in a controllable fashion utilising an inducible promoter in combination with oral agents. Successful plasmid gene transfection in human ex vivo mesenchymal tissue was demonstrated for the first time.

  11. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  12. Aortic obstruction: anatomy and echocardiography

    Directory of Open Access Journals (Sweden)

    Keirns Candace

    2006-09-01

    Full Text Available Abstract Echocardiography is a valuable non-invasive technique for identifying the site and type of aortic obstruction. Knowledge of the morphological details of each type of obstruction is the basis for correct interpretation of the diagnostic images and clinical decisions. This study was undertaken to correlate the echocardiographic images with anatomic specimens of equivalent valvular and supravalvular aortic obstruction. Specimens were part of the collection of the Department of Embryology. Fifty six patients were studied, and forty specimens with aortic obstruction were analyzed. Echocardiographic characteristics: Thirty one (55.3% patients were women and twenty five (44.7% men. Valvular aortic obstruction was found in Thirty six patients (64.3 % and supravalvular aortic obstruction in twenty (35.7%. Anatomic characteristics: Of the forty specimens examined, twenty one (52.5% had valvular aortic obstruction and nineteen (47.5% supravalvular aortic obstruction. The anatomoechocardiographic correlation clearly showed that the anatomic findings of the specimen hearts and aortas corresponded to echocardiographic images of valvular and supravalvular aortic obstruction and provided solid corroboration of echocardiographic diagnoses.

  13. THE DIAGNOSTIC VALUE OF PULSED WAVE TISSUE DOPPLER IMAGING IN ASYMPTOMATIC BETA- THALASSEMIA MAJOR CHILDREN AND YOUNG ADULTS ; RELATION TO CHEMICAL BIOMARKERS OF LEFT VENTRICULAR FUNCTION AND IRON OVERLOAD .

    Directory of Open Access Journals (Sweden)

    Seham Ragab

    2015-08-01

    Full Text Available Background: Cardiac iron toxicity is the leading cause of death among  β-halassaemia major (TM  patients.  Once  heart failure becomes overt , it will be  difficult to reverse . Objectives: To investigate non overt cardiac dysfunctions  in TM patients using  pulsed wave Tissue Doppler  Imaging (TD I and its relation to the iron overload and brain natruritic peptide (BNP. Methods: Thorough  clinical , conventional echo and  pulsed  wave TDI  parameters were compared between  asymtomatic 25 β-TM  patients  and 20 age and gender matched individuals. Serum ferritin and plasma BNP  levels were assayed by  ELISA .  Results: TM patients had significant higher mitral inflow early diastolic (E wave and  non significant other conventional echo  parameters. Pulsed wave TDI revealed systolic and diastolic dysfunctions in the form of significant higher  isovolumetric contraction time (ICT , ejection time ( E T and  isovolumetric relaxation time (IRT with significantly lower  mitral annulus  early diastolic velocity E` (12.07 ±2.06 vs 15.04±2.65 ,P= 0.003  in patients compared to  controls. Plasma BNP was higher in patients compared to the controls.  Plasma BNP and serum ferritin had significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions.  Patients with E/E` ≥ 8 had  significant higher  serum ferritin  and plasma BNP levels compared to those with E/E` ratio < 8 without difference in Hb levels .Conclusion:  Pulsed wave TDI  is an  important diagnostic tool for latent cardiac dysfunction in iron loaded TM patients and is related to iron overload and BNP .

  14. The Diagnostic Value of Pulsed Wave Tissue Doppler Imaging in Asymptomatic Beta- Thalassemia Major Children and Young Adults; Relation to Chemical Biomarkers of Left Ventricular Function and Iron Overload.

    Science.gov (United States)

    Ragab, Seham M; Fathy, Waleed M; El-Aziz, Walaa FAbd; Helal, Rasha T

    2015-01-01

    Cardiac iron toxicity is the leading cause of death among β-halassaemia major (TM) patients. Once heart failure becomes overt, it is difficult to reverse. To investigate non-overt cardiac dysfunctions in TM patients using pulsed wave Tissue Doppler Imaging (TD I) and its relation to iron overload and brain natriuretic peptide (BNP). Thorough clinical, conventional echo and pulsed wave TDI parameters were compared between asymptomatic 25 β-TM patients and 20 age and gender matched individuals. Serum ferritin and plasma BNP levels were assayed by ELISA. TM patients had significant higher mitral inflow early diastolic (E) wave and non significant other conventional echo parameters. In the patient group, pulsed wave TDI revealed systolic dysfunctions, in the form of significant higher isovolumetric contraction time (ICT), and lower ejection time (E T), with diastolic dysfunction in the form of higher isovolumetric relaxation time (IRT), and lower mitral annulus early diastolic velocity E' (12.07 ±2.06 vs 15.04±2.65, P= 0.003) compared to the controls. Plasma BNP was higher in patients compared to the controls. Plasma BNP and serum ferritin had a significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions. Patients with E/E' ≥ 8 had significant higher serum ferritin and plasma BNP levels compared to those with ratio wave TDI is an important diagnostic tool for latent cardiac dysfunction in iron-loaded TM patients and is related to iron overload and BNP.

  15. Transesophageal echocardiography in patients with cryptogenic cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Dreger Henryk

    2009-03-01

    Full Text Available Abstract Background In about one third of all patients with cerebral ischemia, no definite cause can be identified (cryptogenic stroke. In many patients with initially suspected cryptogenic stroke, however, a cardiogenic etiology can eventually be determined. Hence, the aim of this study was to describe the prevalence of abnormal echocardiographic findings in a large number of these patients. Method Patients with cryptogenic cerebral ischemia (ischemic stroke, IS, and transient ischemic attack, TIA were included. The initial work-up included a neurological examination, EEG, cCT, cMRT, 12-lead ECG, Holter-ECG, Doppler ultrasound of the extracranial arteries, and transthoracic echocardiography. A multiplane transeophageal echocardiography (TEE, including i.v. contrast medium application [Echovist], Valsalva maneuver was performed in all patients Results 702 consecutive patients (380 male, 383 IS, 319 TIA, age 18–90 years were included. In 52.6% of all patients, TEE examination revealed relevant findings. Overall, the most common findings in all patients were: patent foramen ovale (21.7%, previously undiagnosed valvular disease (15.8%, aortic plaques, aortic valve sclerosis, atrial septal aneurysms, regional myocardial dyskinesia, dilated left atrium and atrial septal defects. Older patients (> 55 years, n = 291 and patients with IS had more relevant echocardiographic findings than younger patients or patients with TIA, respectively (p = 0.002, p = 0.003. The prevalence rates of PFO or ASD were higher in younger patients (PFO: 26.8% vs. 18.0%, p = 0.005, ASD: 9.6% vs. 4.9%, p = 0.014. Conclusion A TEE examination in cryptogenic stroke reveals contributing cardiogenic factors in about half of all patients. Younger patients had a higher prevalence of PFO, whereas older patients had more frequently atherosclerotic findings. Therefore, TEE examinations seem indicated in all patients with cryptogenic stroke – irrespective of age – because of

  16. The phenomenon of Doppler

    International Nuclear Information System (INIS)

    Stoll, I.; Seidlerova, I.; Schwippel, J.; Poss, O.; Solc, M.

    1992-01-01

    The book is devoted to the life and work of Christian Doppler and particularly to his links to Prague and to the Slovak town of Banska Stiavnica. Many historical facts concerning Doppler's activities as well as the history of physics and astronomy are collected. Information is also presented about the Czech Technical University, the Society of Czechoslovak Mathematicians and Physicists, the Czechoslovak Astronomical Society, the Czechoslovak Spectroscopic Society and the Czechoslovak Society for the History of Science and Technology. The publication is amply supplemented with historical pictorial material (M.D.). 92 figs., 82 refs

  17. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  18. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  19. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  20. Spectral Doppler interrogation of the patent foramen ovale-a window to left heart hemodynamics.

    Science.gov (United States)

    Fadel, Bahaa M; Husain, Aysha; Bakarman, Hatem; Dahdouh, Ziad; Salvo, Giovanni Di; Mohty, Dania

    2015-02-01

    Spectral Doppler interrogation of flow across a patent foramen ovale (PFO) allows recording of the instantaneous pressure gradient between left and right atrium (RA). The assessment of RA pressure using the size and collapsibility of the inferior vena cava would thus allow estimation of left atrial (LA) pressure. In this article, we illustrate the value of spectral Doppler interrogation of flow across the PFO by transthoracic echocardiography as a novel and simple tool for the assessment of LA pressure and left cardiac hemodynamics in addition to the conventional noninvasive parameters. © 2014, Wiley Periodicals, Inc.

  1. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  2. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  3. Digital storage and analysis of color Doppler echocardiograms

    Science.gov (United States)

    Chandra, S.; Thomas, J. D.

    1997-01-01

    Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

  4. Successful thrombectomy of a stuck mechanical prosthetic mitral valve guided by perioperative transesophageal echocardiography and cinefluoroscopy

    Directory of Open Access Journals (Sweden)

    Paulo César Gobert Damasceno Campos

    2009-03-01

    Full Text Available We describe the case of a 53-year-old man with past history of rheumatic valvular disease who developed acute decompensated heart failure due to thrombosis of his mechanical mitral valve prosthesis. The diagnosis was established after a combined and complementary approach of echocardiography and cinefluoroscopy. Because of the severe heart failure at presentation, the patient was taken to surgery. The intraoperative transesophageal echocardiography was critical to guide a successful thrombectomy procedure. Postoperative pathological findings revealed the presence of thrombus and fibrotic tissue (pannus in the surgical specimens removed from the valve. The success of this case and the treatment choice are supported by the most recent literature data on prosthetic valve thrombosis. We highlight the use of three diagnostic approaches in our patient: echocardiography, cinefluoroscopy and pathology.

  5. The usefulness of contrast during exercise echocardiography for the assessment of systolic pulmonary pressure

    Directory of Open Access Journals (Sweden)

    Cordeiro Ana

    2008-10-01

    Full Text Available Abstract Background The systolic pulmonary artery pressure (PAPs can be accurately estimated, non-invasively, using continuous-wave Doppler (CWD ultrasound measurement of the peak velocity of a tricuspid regurgitant (TR jet. However, it is often difficult to obtain adequate tricuspid regurgitation signals for measurement of PAPs, what could lead to its underestimation. Therefore, utilization of air-blood-saline contrast has been implemented for the improvement of Doppler signal in several clinical contexts. It is now recommended in the evaluation of patients with pulmonary hypertension. Physical activity is severely restricted in patients with PAH, being exertional dypnea the most typical symptom. Exercise stress echo-Doppler imaging allows assessment of the response to exercise. It is an excellent screening test for patients with suspected PAH. Our purpose was to evaluate the value and accuracy of agitated saline with blood contrast echocardiography, in the improvement of the Doppler signal, to quantify PAPs during treadmill exercise-echocardiography. Purpose To evaluate the value of contrast echocardiography, using agitated saline with blood, in the improvement of the Doppler signal used to quantify the pulmonary artery systolic pressure during exercise. Methods From a total of 41 patients (pts, we studied 38 pts (93%, 35 women, aged 54 ± 12 years-old. 27 with the diagnosis of systemic sclerosis, 10 with history of pulmonary embolism and one patient with a suspected idiopathic PAH, who were referred to the Unity of Heart Failure and Pulmonary Hypertension for screening of PAH. According to the Unity protocol, a transthoracic echocardiogram was made, in left decubitus (LD, with evaluation of right ventricle-right atria gradient (RV/RAg. A peripheral venous access was obtained, with a 3-way stopcock and the patients were placed in orthostatism (O, with a new evaluation of RV/RAg. Exercise echocardiography (EE was begun, with evaluation of RV

  6. 2010 Canadian Cardiovascular Society/Canadian Society of Echocardiography Guidelines for Training and Maintenance of Competency in Adult Echocardiography.

    Science.gov (United States)

    Burwash, Ian G; Basmadjian, Arsene; Bewick, David; Choy, Jonathan B; Cujec, Bibiana; Jassal, Davinder S; MacKenzie, Scott; Nair, Parvathy; Rudski, Lawrence G; Yu, Eric; Tam, James W

    2011-01-01

    Guidelines for the provision of echocardiography in Canada were jointly developed and published by the Canadian Cardiovascular Society and the Canadian Society of Echocardiography in 2005. Since their publication, recognition of the importance of echocardiography to patient care has increased, along with the use of focused, point-of-care echocardiography by physicians of diverse clinical backgrounds and variable training. New guidelines for physician training and maintenance of competence in adult echocardiography were required to ensure that physicians providing either focused, point-of-care echocardiography or comprehensive echocardiography are appropriately trained and proficient in their use of echocardiography. In addition, revision of the guidelines was required to address technological advances and the desire to standardize echocardiography training across the country to facilitate the national recognition of a physician's expertise in echocardiography. This paper summarizes the new Guidelines for Physician Training and Maintenance of Competency in Adult Echocardiography, which are considerably more comprehensive than earlier guidelines and address many important issues not previously covered. These guidelines provide a blueprint for physician training despite different clinical backgrounds and help standardize physician training and training programs across the country. Adherence to the guidelines will ensure that physicians providing echocardiography have acquired sufficient expertise required for their specific practice. The document will also provide a framework for other national societies to standardize their training programs in echocardiography and will provide a benchmark by which competency in adult echocardiography may be measured. Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  7. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  8. Simulation for transthoracic echocardiography of aortic valve

    Science.gov (United States)

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  9. Doppler-musical instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan); Watanabe, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Shibata, K. [Institute for Materials Research, Tohoku Univ., Sendai, Miyagi (Japan)

    2001-03-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 {mu}eV, even when the ultra-high energy resolution of {delta}E{approx}0.03 {mu}eV is attained. (author)

  10. Echocardiography in the Era of Multimodality Cardiovascular Imaging

    Science.gov (United States)

    Shah, Benoy Nalin

    2013-01-01

    Echocardiography remains the most frequently performed cardiac imaging investigation and is an invaluable tool for detailed and accurate evaluation of cardiac structure and function. Echocardiography, nuclear cardiology, cardiac magnetic resonance imaging, and cardiovascular-computed tomography comprise the subspeciality of cardiovascular imaging, and these techniques are often used together for a multimodality, comprehensive assessment of a number of cardiac diseases. This paper provides the general cardiologist and physician with an overview of state-of-the-art modern echocardiography, summarising established indications as well as highlighting advances in stress echocardiography, three-dimensional echocardiography, deformation imaging, and contrast echocardiography. Strengths and limitations of echocardiography are discussed as well as the growing role of real-time three-dimensional echocardiography in the guidance of structural heart interventions in the cardiac catheter laboratory. PMID:23878804

  11. Recent advances in echocardiography for valvular heart disease.

    Science.gov (United States)

    Hahn, Rebecca

    2015-01-01

    Echocardiography is the imaging modality of choice for the assessment of patients with valvular heart disease. Echocardiographic advancements may have particular impact on the assessment and management of patients with valvular heart disease. This review will summarize the current literature on advancements, such as three-dimensional echocardiography, strain imaging, intracardiac echocardiography, and fusion imaging, in this patient population.

  12. Endocarditis : Effects of routine echocardiography during Gram-positive bacteraemia

    NARCIS (Netherlands)

    Vos, F J; Bleeker-Rovers, C P; Sturm, P D; Krabbe, P F M; van Dijk, A P J; Oyen, W J G; Kullberg, B J

    2011-01-01

    BACKGROUND: Despite firm recommendations to perform echocardiography in high-risk patients with Gram-positive bacteraemia, routine echocardiography is not embedded in daily practice in many settings. The aim of this study was to evaluate whether a regime including routine echocardiography results in

  13. Dynamic 3D echocardiography in virtual reality.

    NARCIS (Netherlands)

    A.E. van den Bosch (Annemien); A.H.J. Koning (Anton); F.J. Meijboom (Folkert); J.S. Vletter-McGhie (Jackie); M.L. Simoons (Maarten); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2005-01-01

    textabstractBACKGROUND: This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. METHODS: Three-dimensional echocardiographic

  14. Dobutamine stress echocardiography: a review and update

    Directory of Open Access Journals (Sweden)

    Gilstrap LG

    2014-04-01

    Full Text Available Lauren Gray Gilstrap,1 R Sacha Bhatia,2 Rory B Weiner,3 David M Dudzinski3 1Division of Cardiology, Brigham and Women's Hospital, Boston, MA, USA; 2Institute for Health Systems Solutions, Women's College Hospital, Toronto, ON, Canada; 3Cardiology Division, Massachusetts General Hospital, Boston, MA, USA Abstract: Stress echocardiography is a noninvasive cardiovascular diagnostic test that provides functional and hemodynamic information in the assessment of a number of cardiac diseases. Performing stress echocardiography with a pharmacologic agent such as dobutamine allows for simulation of increased heart rate and increased myocardial physiologic demands in patients who may be unable to exercise due to musculoskeletal or pulmonary comorbidities. Dobutamine stress echocardiography (DSE, like exercise echocardiography, has found its primary application in ischemic heart disease, with roles in identification of obstructive epicardial coronary artery disease, detection of viable myocardium, and assessment of the efficacy of anti-ischemic medical therapy in patients with known coronary artery disease. DSE features prominently in the evaluation and management of valvular heart disease by helping to assess the effects of mitral and aortic stenoses, as well as a specific use in differentiating true severe valvular aortic stenosis from pseudostenosis that may occur in the setting of left ventricular systolic dysfunction. DSE is generally well tolerated, and its side effects and contraindications generally relate to consequences of excess inotropic and/or chronotropic stimulation of the heart. The aim of this paper is to review the indications, contraindications, advantages, disadvantages, and risks of DSE. Keywords: stress echocardiography, dobutamine, coronary artery disease, myocardial ischemia

  15. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ryohei Suzuki

    2018-02-01

    Full Text Available Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI. The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous.

  16. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    Science.gov (United States)

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  17. Implementation of the stress echocardiography in an echocardiographic laboratory

    International Nuclear Information System (INIS)

    Solis Brizuela, Felix

    2013-01-01

    The logistics for the implementation of the stress echocardiography is defined with based on current recommendations, for an echocardiography laboratory. The protocols established to perform the studies and procedures of this diagnostic method are exposed. The elementary conditions to realize with safety the stress echocardiography are established. Recent literature on the evaluation of new echocardiographic techniques is reviewed to determine their usefulness in stress testing. The assessment of stress echocardiography is developed. The stress echocardiography has been the procedure with high sensitivity and specificity for the diagnosis of coronary artery disease [es

  18. The Doppler echocardiographic myocardial performance index predicts left-ventricular dilation and cardiac death after myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To investigate the value of the Doppler-derived myocardial performance index to predict early left-ventricular (LV) dilation and cardiac death after a first acute myocardial infarction (AMI), Doppler echocardiography was performed within 24 h of hospital admission, on day 5, 1 and 3 months after...... AMI in 125 consecutive patients. The index measured on day 1 correlated well with the change in end-diastolic volume index observed from day 1 to 3 months following AMI (r = 0.66, p 0.0001). One-year survival in patients with Doppler index index > or = 0......, we conclude that the Doppler echocardiographic myocardial performance index is a predictor of LV dilation and cardiac death after a first AMI....

  19. Bedside Echocardiography for Rapid Diagnosis of Malignant Cardiac Tamponade

    Directory of Open Access Journals (Sweden)

    Alaina Brinley

    2017-01-01

    Full Text Available History of present illness: A 47-year-old female with metastatic breast cancer presented to the Emergency Department with chest pain and shortness of breath. She was hypotensive and her EKG showed sinus tachycardia with low voltage. A bedside ultrasound was performed that detected a pericardial effusion and evidence of cardiac tamponade. The patient’s vitals improved with a fluid bolus and she went emergently to the cardiac catheterization lab for fluoroscopy and echocardiography guided pericardiocentesis. A total of 770 mL of fluid was removed from her pericardial space. Significant findings: The video shows a subxiphoid view of the heart with evidence of a large pericardial effusion with tamponade – note the anechoic stripe in the pericardial sac (see red arrow. This video demonstrates paradoxical right ventricular collapse during diastole and right atrial collapse during systole which is indicative of tamponade.1,2 Figure 1 is from the same patient and shows sonographic pulsus paradoxus. This is an apical 4 chamber view of the heart with the sampling gate of the pulsed wave doppler placed over the mitral valve. The Vpeak max and Vpeak min are indicated. If there is more than a 25% difference with inspiration between these 2 values, this is highly suggestive of tamponade.1 In this case, there is a 32.4% difference between the Vpeak max 69.55 cm/s and Vpeak min 46.99 cm/s. Discussion: Cardiac tamponade is distinguished from pericardial effusion by right ventricular compression/collapse and hemodynamic instability. Findings can include hypotension, tachycardia, distant heart sounds, and jugular venous distension.3,4 One might also see a plethoric IVC without respiratory variation indicative of elevated right atrial pressures.1 Detection of right ventricular collapse for cardiac tamponade has sensitivities ranging from 48%-100% and specificities ranging from 33%-100%.5 A larger effusion is more likely to lead to cardiac tamponade. However

  20. Principles of doppler tomography

    International Nuclear Information System (INIS)

    Juhlin, P.

    1992-08-01

    This paper shows how the radon transform can be used to determine vector fields. A scheme to determine the velocity field of a moving fluid by measurements with a continuous doppler signal is suggested. When the flow is confined to a bounded domain, as is the case in most applications, it can be uniquely decomposed into one gradiental and one rotational part. The former vanishes if the fluid is incompressible and source-free, and the latter can be completely reconstructed by the methods proposed in this paper if the domain is simply connected. Special attention is paid to laminar flow in a long cylindrical vessel with circular cross-section. Under such conditions the flow profile becomes parabolic, which makes the vessel recognizable as a typical 'N-shaped' pattern in an image describing the rotation of the velocity field. The vessel yields the same doppler tomographic pattern, no matter how it is sectioned. The ideas presented should be applicable also when studying the flow in blood vessels, even if the flow profile in these is not quite parabolic. The discrepancies only make the 'N-shape' somewhat distorted

  1. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  2. Transthoracic Doppler echocardiography compared with positron emission tomography for assessment of coronary microvascular dysfunction

    DEFF Research Database (Denmark)

    Michelsen, Marie Mide; Mygind, Naja Dam; Pena, Adam

    2017-01-01

    stenosis at invasive coronary angiography, TTDE CFVR by dipyridamole induced stress and MBFR by rubidium-82 PET with adenosine was successfully measured in 107 subjects. Repeatability of TTDE CFVR was assessed in 10 symptomatic women and in 10 healthy individuals. RESULTS: MBFR was systematically higher...... by time-interval between examinations. Results were similar when adjusting for rate pressure product or focusing on perfusion of the left anterior descending artery region. Limits of agreement (CI) for repeated CFVR in 10 healthy individuals and in 10 women with angina was 0.44 (0.21;0.68) and 0.48 (0...

  3. Guideline from Japanese Society of Echocardiography: 2018 focused update incorporated into Guidance for the Management and Maintenance of Echocardiography Equipment.

    Science.gov (United States)

    Daimon, Masao; Akaishi, Makoto; Asanuma, Toshihiko; Hashimoto, Shuji; Izumi, Chisato; Iwanaga, Shiro; Kawai, Hiroya; Toide, Hiroyuki; Hayashida, Akihiro; Yamada, Hirotsugu; Murata, Mitsushige; Hirano, Yutaka; Suzuki, Kengo; Nakatani, Satoshi

    2018-03-01

    Echocardiography plays a pivotal role as an imaging modality in the modern cardiology practice. Information derived from echocardiography is definitely helpful for a patient care. The Japanese Society of Echocardiography has promoted echocardiography for a routine clinical and research use. One of the missions of the Society is to provide information that is useful for high-quality examinations. To ensure it, we believe equipment in good conditions and a comfortable environment are important for both a patient and an examiner. Thus, the Committee for Guideline Writing, the Japanese Society of Echocardiography published brief guidance for the routine use of echocardiography equipment in 2015. Recently, the importance of international standardization has been emphasized in the medical laboratories. Accordingly, the committee has revised and updated our guidance for the routine use of echocardiography equipment.

  4. Echocardiography in the adult's congenital cardiopaties

    International Nuclear Information System (INIS)

    Escobar Q, Carlos I; Jaramillo U, Mario; Tenorio, Luis F; Molina V, Claudia; Saldarriaga A, Marcela; Arango, Angela M

    2003-01-01

    The number of adults with congenital heart disease is steadily increasing in the course of time. We ignore the prevalence and the most frequent diagnoses in our environment. A descriptive prospective study is presented. Between November 1 1999 and July 31 2001, 8871 Tran-thoracic and Tran-esophageal echocardiographies were performed in the Clinica Cardiovascular Santa Maria's echocardiography service. We found 143 congenital cardiopathies (1.6%) in 74 men and 69 women with a mean age of 37.7 +/- 18.4 years. the most frequent diagnoses were bicuspid aortic valve, atrial septal defect, ventricular septal defect, patent ductus arteriosus and Ebstein's anomaly. these findings agree with world wide data

  5. Simulation-based training in echocardiography.

    Science.gov (United States)

    Biswas, Monodeep; Patel, Rajendrakumar; German, Charles; Kharod, Anant; Mohamed, Ahmed; Dod, Harvinder S; Kapoor, Poonam Malhotra; Nanda, Navin C

    2016-10-01

    The knowledge gained from echocardiography is paramount for the clinician in diagnosing, interpreting, and treating various forms of disease. While cardiologists traditionally have undergone training in this imaging modality during their fellowship, many other specialties are beginning to show interest as well, including intensive care, anesthesia, and primary care trainees, in both transesophageal and transthoracic echocardiography. Advances in technology have led to the development of simulation programs accessible to trainees to help gain proficiency in the nuances of obtaining quality images, in a low stress, pressure free environment, often with a functioning ultrasound probe and mannequin that can mimic many of the pathologies seen in living patients. Although there are various training simulation programs each with their own benefits and drawbacks, it is clear that these programs are a powerful tool in educating the trainee and likely will lead to improved patient outcomes. © 2016, Wiley Periodicals, Inc.

  6. Application of Contrast Echocardiography in Invasive Cardiology

    Directory of Open Access Journals (Sweden)

    Mustafa Bulut

    2010-12-01

    Full Text Available Contrast echocardiography by rendering better imaging of the borders of cardiac chambers is a useful tool for evaluating cardiac function, mass, myocardial vascularization, microvascular structure (small vessel vasculature and viability. Contrast was first started to be used for patients with suboptimal image quality. It can be used in detecting defects in myocardial blood supply in patients with chest pain and determining the success of interventionalprocedures. It can also be of help in demonstrating myocardial viability after reperfusion treatment in patients who had myocardial infarction. It is expected to be used more widely in invasive cardiology for decision making, guiding and determining the success of the procedures. Advances in imaging techniques , development of contrast materials for evaluation of left system, contrast echocardiography may become a routine clinical practice.

  7. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  8. Exercise echocardiography for structural heart disease.

    Science.gov (United States)

    Izumo, Masaki; Akashi, Yoshihiro J

    2016-03-01

    Since the introduction of transcatheter structural heart intervention, the term "structural heart disease" has been widely used in the field of cardiology. Structural heart disease refers to congenital heart disease, valvular heart disease, and cardiomyopathy. In structural heart disease, valvular heart disease is frequently identified in the elderly. Of note, the number of patients who suffer from aortic stenosis (AS) and mitral regurgitation (MR) is increasing in developed countries because of the aging of the populations. Transcatheter aortic valve replacement and percutaneous mitral valve repair has been widely used for AS and MR, individually. Echocardiography is the gold standard modality for initial diagnosis and subsequent evaluation of AS and MR, although the difficulties in assessing patients with these diseases still remain. Here, we review the clinical usefulness and prognostic impact of exercise echocardiography on structural heart disease, particularly on AS and MR.

  9. Pericardial Effusion and Pericardiocentesis: Role of Echocardiography

    Science.gov (United States)

    2012-01-01

    Pericardial effusion can develop from any pericardial disease, including pericarditis and several systemic disorders, such as malignancies, pulmonary tuberculosis, chronic renal failure, thyroid diseases, and autoimmune diseases. The causes of large pericardial effusion requiring invasive pericardiocentesis may vary according to the time, country, and hospital. Transthoracic echocardiography is the most important tool for diagnosis, grading, the pericardiocentesis procedure, and follow up of pericardial effusion. Cardiac tamponade is a kind of cardiogenic shock and medical emergency. Clinicians should understand the tamponade physiology, especially because it can develop without large pericardial effusion. In addition, clinicians should correlate the echocardiographic findings of tamponade, such as right ventricular collapse, right atrial collapse, and respiratory variation of mitral and tricuspid flow, with clinical signs of clinical tamponade, such as hypotension or pulsus paradoxus. Percutaneous pericardiocentesis has been the most useful procedure in many cases of large pericardial effusion, cardiac tamponade, or pericardial effusion of unknown etiology. The procedure should be performed with the guidance of echocardiography. PMID:23236323

  10. Echocardiography diagnosis of myocardial infarction complications

    Directory of Open Access Journals (Sweden)

    N.D. Oryshchyn

    2016-03-01

    Full Text Available Diagnosis and management of myocardial infarction complications are discussed in this article. These complications are associated with high level of mortality and surgery is a main treatment method. High level of suspicion and early diagnosis are essential for appropriate treatment and improvement of prognosis. Echocardiography is a main diagnostic method. Analysis of literature about contemporary management of mechanical complications of myocardial infarction has been performed, case reports are presented.

  11. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  12. Deconvoluting double Doppler spectra

    International Nuclear Information System (INIS)

    Ho, K.F.; Beling, C.D.; Fung, S.; Chan, K.L.; Tang, H.W.

    2001-01-01

    The successful deconvolution of data from double Doppler broadening of annihilation radiation (D-DBAR) spectroscopy is a promising area of endeavour aimed at producing momentum distributions of a quality comparable to those of the angular correlation technique. The deconvolution procedure we test in the present study is the constrained generalized least square method. Trials with computer simulated DDBAR spectra are generated and deconvoluted in order to find the best form of regularizer and the regularization parameter. For these trials the Neumann (reflective) boundary condition is used to give a single matrix operation in Fourier space. Experimental D-DBAR spectra are also subject to the same type of deconvolution after having carried out a background subtraction and using a symmetrize resolution function obtained from an 85 Sr source with wide coincidence windows. (orig.)

  13. Adaptive Spectral Doppler Estimation

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-01-01

    . The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to pro- vide good spectral resolution and contrast even when the ob- servation window is very short. The 2 adaptive techniques are tested......In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence...... and compared with the averaged periodogram (Welch’s method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set...

  14. Prognostic value of clinical and Doppler echocardiographic findings in children and adolescents with significant rheumatic valvular disease

    International Nuclear Information System (INIS)

    Araújo, Fátima Derlene da Rocha; Goulart, Eugênio Marcos Andrade; Meira, Zilda Maria Alves

    2012-01-01

    The diagnosis of acute rheumatic fever (RF) is based on clinical findings. However, during the chronic phase of the disease, the clinical approach is not sufficient for the follow-up of the patients and the Doppler echocardiography is a tool for the diagnosis of cardiac involvement. Prognostic variables that influence long-term outcomes are not well known. 462 patients with RF according to Jones criteria were studied, and followed-up from the initial attack to 13.6 ± 4.6 years. All patients underwent clinical assessment and Doppler echocardiography for the detection of heart valve involvement in the acute and chronic phases. Multivariate logistic regression analysis was used to identify the factors influencing long-term heart valve disease. Carditis occurred in 55.8% and subclinical valvulitis in 35.3% patients. In the chronic phase, 33% of the patients had significant valvular heart disease. No normal Doppler echocardiography exam was observed on patients who had severe valvulitis, although heart auscultation had become normal in 13% of these. In the multivariate analysis, only the severity of carditis and the mitral and/or aortic valvulitis were associated with significant valvular heart disease. Chorea or arthritis were protective factors for significant valvular heart disease, odds ratio 0.41 (95% C.I. 0.22 – 0.77) and 0.43 (95% C.I. 0.23 – 0.82), respectively. Our study suggests that the use of Doppler echocardiography during RF helps to identify prognostic factors regarding the development of significant valvular heart disease. Initial severe carditis is an important factor in the long-term prognosis of chronic RHD, whereas arthritis and chore during the initial episode of RF appears to be protective. Strict secondary prophylaxis should be mandatory in high risk patients

  15. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    Science.gov (United States)

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  16. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  17. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2014-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  18. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/ critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  19. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  20. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    Science.gov (United States)

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  1. Association Between Echocardiography Laboratory Accreditation and the Quality of Imaging and Reporting for Valvular Heart Disease.

    Science.gov (United States)

    Thaden, Jeremy J; Tsang, Michael Y; Ayoub, Chadi; Padang, Ratnasari; Nkomo, Vuyisile T; Tucker, Stephen F; Cassidy, Cynthia S; Bremer, Merri; Kane, Garvan C; Pellikka, Patricia A

    2017-08-01

    It is presumed that echocardiographic laboratory accreditation leads to improved quality, but there are few data. We sought to compare the quality of echocardiographic examinations performed at accredited versus nonaccredited laboratories for the evaluation of valvular heart disease. We enrolled 335 consecutive valvular heart disease subjects who underwent echocardiography at our institution and an external accredited or nonaccredited institution within 6 months. Completeness and quality of echocardiographic reports and images were assessed by investigators blinded to the external laboratory accreditation status and echocardiographic results. Compared with nonaccredited laboratories, accredited sites more frequently reported patient sex (94% versus 78%; P heart disease. Future quality improvement initiatives should highlight the importance of high-quality color Doppler imaging and echocardiographic quantification to improve the accuracy, reproducibility, and quality of echocardiographic studies for valvular heart disease. © 2017 American Heart Association, Inc.

  2. Transversal Doppler-Fizeau effect

    International Nuclear Information System (INIS)

    Subacius, E.

    1981-01-01

    The relativistic calculation of the Doppler-Fizeau effect foresees a second grade redshift due to the proper time dilation of a moving object. The relevance of this relativistic effect on astrophysical observation is discussed, herein. (Auhor) [pt

  3. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  4. TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH CEREBRAL ISCHEMIA

    Directory of Open Access Journals (Sweden)

    Kavian Ghandehari

    2010-12-01

    Full Text Available Abstract INTRODUCTION: Transesophageal echocardiography (TEE is superior to Transthoracic echocardiography (TTE in detection of atrial septal defects and aneurysm, aortic atheroma, left atrial thrombus and mitral valve abnormalities. TEE is indicated in young adults with cryptogenic ischemic stroke who are suspected of having cardioembolic mechanism despite non-diagnostic TTE. METHODS: A prospective clinical study was conducted in patients with ischemic stroke or TIA who had TTE done in Ghaem hospital, Mashhad during 2006-2007. Ischemic cerebrovascular events were detected by stroke neurologist. TEE was performed with VIPI3/GE device, USA and a 7 MHz transesophageal probe by an echocardiologist. Patients who did not have TTE before TEE were excluded. Comparison of TEE to TTE results was performed by the echocardiologist and stroke neurologist in each patient. Influence of TEE on therapeutic decisions in each patient was evaluated. RESULTS: Forty-seven patients (20 females, 27 males with a mean age of 42.6±7.3 years were studied. Cardiac and aortic abnormalities were detected in TEE of 35 cases (35/47; 74% with ischemic cerebrovascular events. Cardiac abnormalities of 17 cases (36% were only detectable by TEE. These seventeen cases included 7 patients with PFO, 1 case with ASD, 6 cases with aortic atheroma and 2 patients with clot in the left atrium. Comparing the preventive stroke strategies before and after TEE revealed that it was changed only in two cases (2/47; 4.3% due to performing TEE. These included one patient with a small high-risk PFO and another case with dehicense of mechanical mitral valve. CONCLUSION: TEE revealed cardiac or aortic abnormalities in one-third of the patients with cerebral ischemia and has not been detected by TEE previously. The influence of TEE in therapeutic decisions of patients with ischemic cerebrovascular events is very low.         Keywords: Transesophageal echocardiography, Stroke, Transient Ischemic

  5. Doppler-broadening of positron annihilation in a biological environment

    International Nuclear Information System (INIS)

    Torrisi, L.; La Mela, C.; Catania, Univ.

    1997-01-01

    The aim of this study was to investigate the Doppler effect of the 511 keV γ peak from positron annihilation in biological matter: The broadening of the annihilation peak is due to positron annihilation with electrons that have high momentum. In aqueous solutions annihilation depends on the temperature and it is linked positronium formation. Measurements in vivo, on human brain, were taken during the diagnosis of positron emission tomography (PET) on healthy patients by injecting them with the beta emitter of short lifetime 18F . The Doppler-broadening in biological tissues rich in water content decreased significantly compared to biological solutions and water

  6. Frequency of cardiac defects among children at echocardiography centre in a teaching hospital

    International Nuclear Information System (INIS)

    Malik, A.S.; Majeed, R.; Channer, M.S.; Saleem, M.I.

    2010-01-01

    Objective: To assess frequency of cardiac defects among children from birth to 12 years of age on each Methodology: A cross sectional study was conducted at echocardiography centre in coronary care unit at Bahawal Victoria Hby Paediatric Transthoracic echo probe; 2-D colour Doppler, Acuson CV-70 and Niemo-30 echocardiography machines. Mothers of children with cardiac defects were interviewed at the echocardiography centre. Variables included were A- Muscular plus Vascular defects; B- Valvular defects; C-Pericardial effusion; D- Dextrocardia and E- Congestive cardiac failure. History of children for sore throat followed by joint pains; history of mothers for drug intake (antihypertensive, antipyretic, anti-emetic, hypoglycaemic) as well as chronic diseases (diabetes mellitus, hypertension, anaemia) during pregnancy were surveyed. Parity of mothers, their cousin marriages, and family socio-economic status was also inquired. The results were tabulated, analyzed and finally subjected to suitable test of significant (SR of proportion) to find out statistical significant if any. Results: It was found that out of 150 patients, 76 (50.66%) were suffering from Cardiac muscular and Vascular defects, 61 (40.66%) Valvular defects, 7 (4.66%) Pericardial effusion, 2 (1.33%) Dextrocardia and 4 (2.66%) from Congestive Cardiac Failure. According to age, 54 (36%) were from birth to 3 years of age and 51 (34%) from 10 to 12 years. There was history of Rheumatic fever among 45 (30%) children. There were 106 (70.6%) children from lower socio-economic class and 79 (52.6%) parents had history of cousin marriages. Conclusion: Frequency of cardiac defects was more in children of male sex, lower socio-economic group, from birth to three years age and children from primipara mothers in our specified locality. Rheumatic fever, cousin's marriage, and prescribed drugs intake during pregnancy (for metabolic and hormonal disorders) were other contributors to cardiac defects. (author)

  7. Glare Spot Phase Doppler Anemometry

    OpenAIRE

    Hespel, Camille; Ren, Kuan Fang; Gréhan, Gérard; Onofri, Fabrice

    2006-01-01

    International audience; The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index is also necessary since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemo...

  8. High prevalence of rheumatic heart disease detected by echocardiography in school children.

    Science.gov (United States)

    Bhaya, Maneesha; Panwar, Sadik; Beniwal, Rajesh; Panwar, Raja Babu

    2010-04-01

    It is fairly easy to detect advanced valve lesions of established rheumatic heart disease by echocardiography in the clinically identified cases of rheumatic heart disease. However, to diagnose a subclinical case of rheumatic heart disease, no uniform set of echocardiographic criteria exist. Moderate thickening of valve leaflets is considered an indicator of established rheumatic heart disease. World Health Organization criteria for diagnosing probable rheumatic heart disease are more sensitive and are based on the detection of significant regurgitation of mitral and/or aortic valves by color Doppler. We attempted diagnosing RHD in school children in Bikaner city by cardiac ultrasound. The stratified cluster sampling technique was employed to identify 31 random clusters in the coeducational schools of Bikaner city. We selected 1059 school children aged 6-15 years from these schools. An experienced operator did careful cardiac auscultation and echocardiographic study. A second expert confirmed the echocardiographic findings. The prevalence of lesions suggestive of rheumatic heart disease by echocardiography was 51 per 1,000 (denominator = 1059; 95% CI: 38-64 per 1,000). We were able to clinically diagnose RHD in one child. None of these children or their parents having echocardiographic evidence of RHD could provide a positive history of acute rheumatic fever. By echocardiographic screening, we found a high prevalence of rheumatic heart disease in the surveyed population. Clinical auscultation had much lower diagnostic efficacy.

  9. Measurement of Thrombus Flux Using Transesophageal Echocardiography

    Science.gov (United States)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya, Hiroyuki

    2006-05-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the FSET to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed.

  10. Predicting and measuring fluid responsiveness with echocardiography

    Directory of Open Access Journals (Sweden)

    Ashley Miller

    2016-06-01

    Full Text Available Echocardiography is ideally suited to guide fluid resuscitation in critically ill patients. It can be used to assess fluid responsiveness by looking at the left ventricle, aortic outflow, inferior vena cava and right ventricle. Static measurements and dynamic variables based on heart–lung interactions all combine to predict and measure fluid responsiveness and assess response to intravenous fluid esuscitation. Thorough knowledge of these variables, the physiology behind them and the pitfalls in their use allows the echocardiographer to confidently assess these patients and in combination with clinical judgement manage them appropriately.

  11. Measurement of thrombus flux using transesophageal Echocardiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya Hiroyuki

    2006-01-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the fiber structure extraction technique (FSET) to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed. (author)

  12. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  13. Determinants of Pediatric Echocardiography Laboratory Productivity: Analysis from the Second Survey of the American Society of Echocardiography Committee on Echocardiography Laboratory Productivity.

    Science.gov (United States)

    Srivastava, Shubhika; Allada, Vivekanand; Younoszai, Adel; Lopez, Leo; Soriano, Brian D; Fleishman, Craig E; Van Hoever, Andrea M; Lai, Wyman W

    2016-10-01

    The American Society of Echocardiography Committee on Pediatric Echocardiography Laboratory Productivity aimed to study factors that could influence the clinical productivity of physicians and sonographers and assess longitudinal trends for the same. The first survey results indicated that productivity correlated with the total volume of echocardiograms. Survey questions were designed to assess productivity for (1) physician full-time equivalent (FTE) allocated to echocardiography reading (echocardiograms per physician FTE per day), (2) sonographer FTE (echocardiograms per sonographer FTE per year), and (3) machine utilization (echocardiograms per machine per year). Questions were also posed to assess work flow and workforce. For fiscal year 2013 or academic year 2012-2013, the mean number of total echocardiograms-including outreach, transthoracic, fetal, and transesophageal echocardiograms-per physician FTE per day was 14.3 ± 5.9, the mean number of echocardiograms per sonographer FTE per year was 1,056 ± 441, and the mean number of echocardiograms per machine per year was 778 ± 303. Both physician and sonographer productivity was higher at high-volume surgical centers and with echocardiography slots scheduled concordantly with clinic visits. Having an advanced imaging fellow and outpatient sedation correlated negatively with clinical laboratory productivity. Machine utilization was greater in laboratories with higher sonographer and physician productivity and lower for machines obtained before 2009. Measures of pediatric echocardiography laboratory staff productivity and machine utilization were shown to correlate positively with surgical volume, total echocardiography volumes, and concordant echocardiography scheduling; the same measures correlated negatively with having an advanced imaging fellow and outpatient sedation. There has been no significant change in staff productivity noted over two Committee on Pediatric Echocardiography Laboratory

  14. Modeling and processing of laser Doppler reactive hyperaemia signals

    Science.gov (United States)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  15. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    Science.gov (United States)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  16. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  17. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  18. Practical guidance for the implementation of stress echocardiography.

    Science.gov (United States)

    Suzuki, Kengo; Hirano, Yutaka; Yamada, Hirotsugu; Murata, Mitsushige; Daimon, Masao; Takeuchi, Masaaki; Seo, Yoshihiro; Izumi, Chisato; Akaishi, Makoto

    2018-06-06

    Exercise stress testing has been widely undertaken for the diagnosis of heart diseases. The accurate assessment of clinical conditions can be conducted by comparing the findings obtained from the results of stress echocardiography with the changes in the blood/heart rate and electrocardiograms. Numerous overseas studies have reported the utility of stress echocardiography in diagnosing myocardial ischemia; in Japan, the use of this modality for this purpose was included in the national health insurance reimbursable list in 2012. Nevertheless, stress echocardiography is far from being a widespread practice in Japan. This might be due to insufficient equipment (e.g., ergometers, space for test implementation) at each medical institution, shortage of technicians and sonographers who are well experienced and who are responsible for obtaining images during stress testing. The other possible reasons include the limited evidence available in Japan and the lack of a standardized testing protocol. Further dissemination of the practice of exercise stress echocardiography in this country is deemed necessary to establish satisfactory evidence for the use of stress echocardiography in the Japanese population. To this end, efforts are underway to develop a standardized protocol and report format to be adopted throughout Japan. We here present a guideline created by the Guideline Development Committee of the Japanese Society of Echocardiography that describes safe and effective stress echocardiography protocols and report formats. The readers are encouraged to perform exercise stress echocardiography using the proposed template for consensus document and report attached to this guideline.

  19. Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins.

    Science.gov (United States)

    Sun, Xue; Zhang, Ying; Fan, Miao; Wang, Yu; Wang, Meilian; Siddiqui, Faiza Amber; Sun, Wei; Sun, Feifei; Zhang, Dongyu; Lei, Wenjia; Hu, Guyue

    2017-06-01

    Prenatal diagnosis of fetal total anomalous pulmonary vein connection (TAPVC) remains challenging for most screening sonographers. The purpose of this study was to evaluate the use of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation (4D-HDFI) in identifying pulmonary veins in normal and TAPVC fetuses. We retrospectively reviewed and performed 4D-HDFI in 204 normal and 12 fetuses with confirmed diagnosis of TAPVC. Cardiac volumes were available for postanalysis to obtain 4D-rendered images of the pulmonary veins. For the normal fetuses, two other traditional modalities including color Doppler and HDFI were used to detect the number of pulmonary veins and comparisons were made between each of these traditional methods and 4D-HDFI. For conventional echocardiography, HDFI modality was superior to color Doppler in detecting more pulmonary veins in normal fetuses throughout the gestational period. 4D-HDFI was the best method during the second trimester of pregnancy in identifying normal fetal pulmonary veins. 4D-HDFI images vividly depicted the figure, course, and drainage of pulmonary veins in both normal and TAPVC fetuses. HDFI and the advanced 4D-HDFI technique could facilitate identification of the anatomical features of pulmonary veins in both normal and TAPVC fetuses; 4D-HDFI therefore provides additional and more precise information than conventional echocardiography techniques. © 2017, Wiley Periodicals, Inc.

  20. MODERN POSSIBILITIES OF SPECKLE TRACKING ECHOCARDIOGRAPHY IN CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    V. S. Nikiforov

    2017-01-01

    Full Text Available Speckle-tracking echocardiography is promising modern technique for evaluation of structural and functional changes in the myocardium. It evaluates the indicator of global longitudinal myocardial deformation, which is more sensitive than ejection fraction to early changes of left ventricular contractility. The diagnostic capabilities of speckle tracking echocardiography are reflected in clinical recommendations and consensus statements of European Society of Cardiology (ESC, European Association of Cardiovascular Imaging (EACVI and American Society of Echocardiography (ASE. The aim of this paper is describe basic principles of speckle tracking echocardiography and clinical applications of this new technology. Attention is paid to the use of speckle tracking echocardiography in such heart pathologies as heart failure, coronary heart disease and myocardial infarction, left ventricular hypertrophy in arterial hypertension, hypertrophic cardiomyopathy and amyloidosis of the heart, valvular heart disease, constrictive pericarditis and cancer therapy-induced cardiotoxicity.

  1. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  2. Left Ventricular Stroke Volume Quantification by Contrast Echocardiography – Comparison of Linear and Flow-Based Methods to Cardiac Magnetic Resonance

    Science.gov (United States)

    Dele-Michael, Abiola O.; Fujikura, Kana; Devereux, Richard B; Islam, Fahmida; Hriljac, Ingrid; Wilson, Sean R.; Lin, Fay; Weinsaft, Jonathan W.

    2014-01-01

    Background Echocardiography (echo) quantified LV stroke volume (SV) is widely used to assess systolic performance after acute myocardial infarction (AMI). This study compared two common echo approaches – predicated on flow (Doppler) and linear chamber dimensions (Teichholz) – to volumetric SV and global infarct parameters quantified by cardiac magnetic resonance (CMR). Methods Multimodality imaging was performed as part of a post-AMI registry. For echo, SV was measured by Doppler and Teichholz methods. Cine-CMR was used for volumetric SV and LVEF quantification, and delayed-enhancement CMR for infarct size. Results 142 patients underwent same-day echo and CMR. On echo, mean SV by Teichholz (78±17ml) was slightly higher than Doppler (75±16ml; Δ=3±13ml, p=0.02). Compared to SV on CMR (78±18ml), mean difference by Teichholz (Δ=−0.2±14; p=0.89) was slightly smaller than Doppler (Δ−3±14; p=0.02) but limits of agreement were similar between CMR and echo methods (Teichholz: −28, 27 ml, Doppler: −31, 24ml). For Teichholz, differences with CMR SV were greatest among patients with anteroseptal or lateral wall hypokinesis (p<0.05). For Doppler, differences were associated with aortic valve abnormalities or root dilation (p=0.01). SV by both echo methods decreased stepwise in relation to global LV injury as assessed by CMR-quantified LVEF and infarct size (p<0.01). Conclusions Teichholz and Doppler calculated SV yield similar magnitude of agreement with CMR. Teichholz differences with CMR increase with septal or lateral wall contractile dysfunction, whereas Doppler yields increased offsets in patients with aortic remodeling. PMID:23488864

  3. Echocardiography as an indication of continuous-time cardiac quiescence

    Science.gov (United States)

    Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.

    2016-07-01

    Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a

  4. Doppler echocardiographic evaluation of HIV-positive patients in different stages of the disease

    Directory of Open Access Journals (Sweden)

    Werneck Guilherme Lobosco

    1999-01-01

    Full Text Available OBJETIVE: To evaluate by Doppler echocardiography (DE early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A and 25 with CD4 cell count 500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³, had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

  5. Doppler Broadening Calculations of Compton Scattering for Molecules, Plastics, Tissues, and Few Biological Materials in the X-Ray Region: An Analysis in Terms of Compton Broadening and Geometrical Energy Broadening

    Science.gov (United States)

    Rao, D. V.; Cesareo, R.; Brunetti, A.; Gigante, G. E.; Akatsuka, T.; Takeda, T.; Itai, Y.

    2004-09-01

    Relativistic and nonrelativistic Compton profile cross sections for H, C, N, O, P, and Ca and for a few important biological materials such as water, polyethylene, lucite, polystyrene, nylon, polycarbonate, bakelite, fat, bone and calcium hydroxyapatite are estimated for a number of Kα x-ray energies and for 59.54 keV (Am-241) γ photons. Energy broadening and geometrical broadening (ΔG) is estimated by assuming θmin and θmax are symmetrically situated around θ=90°. FWHM of J(PZ) and FWHM of Compton energy broadening are evaluated at various incident photon energies. These values are estimated around the centroid of the Compton profile with an energy interval of 0.1 and 1.0 keV for 59.54 keV photons. Total Compton, individual shell, and Compton energy-absorption scattering cross sections are evaluated in the energy region from 0.005 to 0.5 MeV. It is an attempt to know the effect of Doppler broadening for single atoms, many of which constitute the biological materials.

  6. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  7. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran's Electronic Health Record (EHR) System.

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-04-01

    Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. to determine the minimum data set of echocardiography reporting system to exchange with Iran's electronic health record (EHR) system. First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients' records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. The highest degree of consensus was found for the following MDSs: patient's name and family name (5), accepting doctor's name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran's electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider.

  8. Diagnostic and prognostic value of right ventricular strain in patients with pulmonary arterial hypertension and relatively preserved functional capacity studied with echocardiography and magnetic resonance.

    Science.gov (United States)

    da Costa Junior, Augusto Alberto; Ota-Arakaki, Jaquelina Sonoe; Ramos, Roberta Pulcheri; Uellendahl, Marly; Mancuso, Frederico José Neves; Gil, Manuel Adan; Fischer, Cláudio Henrique; Moises, Valdir Ambrosio; de Camargo Carvalho, Antonio Carlos; Campos, Orlando

    2017-01-01

    Right ventricular (RV) dysfunction harbingers adverse prognosis in pulmonary arterial hypertension (PAH). Although conventional two-dimensional echocardiography (2DE) is limited for RV systolic function quantitation, RV strain can be a useful tool. The diagnostic and prognostic impact of 2DE speckle-tracking RV longitudinal strain was evaluated, including other 2DE systolic indexes, in a group of PAH patients without severe impairment of functional capacity, chronic pulmonary thromboembolism or left ventricular dysfunction. Sixty-six group I PAH patients, 67 % NYHA functional class I or II (none in IV) were studied by 2DE to obtain: RV fractional area change, tricuspid annular plane systolic excursion, RV myocardial performance index, tissue Doppler tricuspid annulus systolic velocity. Global, free wall (RVFreeWSt) and septal RV longitudinal systolic strain were obtained. RV ejection fraction by cardiac magnetic resonance (CMR-RVEF) was also assessed. All patients were followed up to 3.9 years (mean 3.3 years). Combined endpoints were hospitalization for worsening PAH or cardiovascular death. Among all the 2DE indexes of RV systolic function, RVFreeWSt exhibited the best correlation with CMR-RVEF (r = 0.83; p < 0.005). Combined endpoints occurred in 15 (22.7 %) patients (6 hospitalizations and 9 deaths). Multivariate analysis identified RVFreeWSt ≤-14 % as the only 2DE independent variable associated with combined endpoints [HR 4.66 (1.25-17.37); p < 0.05]. We conclude that RVFreeWSt may be a suitable non-geometric 2DE surrogate of CMR-RVEF in PAH patients, constituting a powerful independent predictor of long-term outcome in this cohort with relatively preserved functional capacity.

  9. Value of tissue Doppler-derived Tei index and two-dimensional speckle tracking imaging derived longitudinal strain on predicting outcome of patients with light-chain cardiac amyloidosis.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Herrmann, Sebastian; Cikes, Maja; Ertl, Georg; Weidemann, Frank; Störk, Stefan; Nordbeck, Peter

    2017-06-01

    Prognosis of patients with light-chain cardiac amyloidosis (AL-CA) is poor. Speckle tracking imaging (STI) derived longitudinal deformation parameters and Doppler-derived left ventricular (LV) Tei index are valuable predictors of outcome in patients with AL-CA. We estimated the prognostic utility of Tei index and deformation parameters in 58 comprehensively phenotyped patients with AL-CA after a median follow-up of 365 days (quartiles 121, 365 days). The primary end point was all-cause mortality. 19 (33%) patients died during follow-up. Tei index (0.89 ± 0.29 vs. 0.61 ± 0.16, p < 0.001) and E to global early diastolic strain rate ratio (E/GLSR dias ) were higher while global longitudinal systolic strain (GLS sys ) was lower in non-survivors than in survivors (all p < 0.05). Tei index, NYHA functional class, GLS sys and E/GLSR dias were independent predictors of all-cause mortality risk, and Tei index ≥0.9 (HR 7.01, 95% CI 2.43-20.21, p < 0.001) was the best predictor of poor outcome. Combining Tei index and GLS sys yielded the best results on predicting death within 1 year (100% with Tei index ≥0.9 and GLS sys ≤13%) or survival (95% with Tei index ≤0.9 and GLS sys ≥13%). We conclude that 1-year mortality risk in AL-CA patients can be reliably predicted using Tei index or deformation parameters, with combined analysis offering best performance.

  10. Doppler broadening of cross sections

    International Nuclear Information System (INIS)

    Buckler, P.A.C.; Pull, I.C.

    1962-12-01

    Expressions for temperature dependent cross-sections in terms of resonance parameters are obtained, involving generalisations of the conventional Doppler functions, ψ and φ. Descriptions of Fortran sub-routines, which calculate broadened cross-sections in accordance with the derived formulae, are included. (author)

  11. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  12. Doppler echocardiographic study in adolescents and young adults with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Wolney de Andrade Martins

    1999-12-01

    Full Text Available OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA. METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS. The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

  13. Teaching focused echocardiography for rheumatic heart disease screening

    Directory of Open Access Journals (Sweden)

    Daniel Engelman

    2015-01-01

    Full Text Available Screening for rheumatic heart disease (RHD requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities.

  14. Teaching focused echocardiography for rheumatic heart disease screening

    International Nuclear Information System (INIS)

    Engelman, Daniel; Kado, Joseph H; Reményi, Bo; Colquhoun, Samantha M; Watson, Caroline; Rayasidamu, Sera C; Steer, Andrew C

    2005-01-01

    Screening for rheumatic heart disease (RHD) requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis) and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities

  15. Intra-cardiac echocardiography in alcohol septal ablation

    DEFF Research Database (Denmark)

    Cooper, Robert M; Shahzad, Adeel; Newton, James

    2015-01-01

    Alcohol septal ablation (ASA) in hypertrophic obstructive cardiomyopathy reduces left ventricular outflow tract gradients. A third of patients do not respond; inaccurate localisation of the iatrogenic infarct can be responsible. Transthoracic echocardiography (TTE) using myocardial contrast can...

  16. Angio- and echocardiography: viewing heart defects in more detail

    International Nuclear Information System (INIS)

    Goodwin, J.K.; Lombard, C.W.

    1990-01-01

    Angio- and echocardiography can help to confirm the diagnosis or evaluate the severity of a heart defect. Angiograms of dogs with pulmonic stenosis and tetralogy of Fallot are shown. Echocardiographic features of common congenital heart defects are summarized

  17. Intraoperative transesophageal echocardiography in congenital heart diseases surgery

    International Nuclear Information System (INIS)

    Ozores Suarez, Francisco Javier; Perez de Ordaz, Luis Bravo

    2010-01-01

    The intraoperative transesophageal echocardiography is very used in pediatric cardiovascular surgery. The aim of present paper was to determine its impact on the surgery immediate results after a previous experience of authors with this type of procedure

  18. Three-dimensional transesophageal echocardiography of the atrial septal defects

    Directory of Open Access Journals (Sweden)

    Romero-Cárdenas Ángel

    2008-07-01

    Full Text Available Abstract Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

  19. Speckle tracking echocardiography in acute lupus myocarditis: comparison to conventional echocardiography

    Directory of Open Access Journals (Sweden)

    Riëtte Du Toit

    2017-07-01

    Full Text Available Aims: Lupus myocarditis occurs in 5–10% of patients with systemic lupus erythematosus (SLE. No single feature is diagnostic of lupus myocarditis. Speckle tracking echocardiography (STE can detect subclinical left ventricular dysfunction in SLE patients, with limited research on its utility in clinical lupus myocarditis. We report on STE in comparison to conventional echocardiography in patients with clinical lupus myocarditis. Methods and results: A retrospective study was done at a tertiary referral hospital in South Africa. SLE patients with lupus myocarditis were included and compared to healthy controls. Echocardiographic images were reanalyzed, including global longitudinal strain through STE. A poor echocardiographic outcome was defined as final left ventricular ejection fraction (LVEF <40%. 28 SLE patients fulfilled the criteria. Global longitudinal strain correlated with global (LVEF: r = −0.808; P = 0.001 and regional (wall motion score: r = 0.715; P < 0.001 function. In patients presenting with a LVEF ≥50%, global longitudinal strain (P = 0.023, wall motion score (P = 0.005 and diastolic function (P = 0.004 were significantly impaired vs controls. Following treatment, LVEF (35–47% (P = 0.023 and wall motion score (1.88–1.5 (P = 0.017 improved but not global longitudinal strain. Initial LVEF (34%; P = 0.046 and global longitudinal strain (−9.5%; P = 0.095 were lower in patients with a final LVEF <40%. Conclusions: This is the first known report on STE in a series of patients with clinical lupus myocarditis. Global longitudinal strain correlated with regional and global left ventricular function. Global longitudinal strain, wall motion score and diastolic parameters may be more sensitive markers of lupus myocarditis in patients presenting with a preserved LVEF ≥50%. A poor initial LVEF and global longitudinal strain were associated with a persistent LVEF <40%. Echocardiography is a non-invasive tool with diagnostic and

  20. Avoiding transthoracic echocardiography and transesophageal echocardiography for patients with variable body mass indexes in infective endocarditis

    Directory of Open Access Journals (Sweden)

    Robert Sogomonian

    2016-04-01

    Full Text Available Background: Echocardiography has been a popular modality used to aid in the diagnosis of infective endocarditis (IE with the modified Duke criteria. We evaluated the necessity between the uses of either a transthoracic echocardiography (TTE or transesophageal echocardiography (TEE in patients with a body mass index (BMI greater than or equal to 25 kg/m2 and less than 25 kg/m2. Methods: A single-centered, retrospective study of 198 patients between 2005 and 2012 diagnosed with IE based on modified Duke criteria. Patients, required to be above age 18, had undergone an echocardiogram study and had blood cultures to be included in the study. Results: Among 198 patients, two echocardiographic groups were evaluated as 158 patients obtained a TTE, 143 obtained a TEE, and 103 overlapped with TEE and TTE. Out of these patients, 167 patients were included in the study as 109 (65% were discovered to have native valve vegetations on TEE and 58 (35% with TTE. TTE findings were compared with TEE results for true negatives and positives to isolate valvular vegetations. Overall sensitivity of TTE was calculated to be 67% with a specificity of 93%. Patients were further divided into two groups with the first group having a BMI ≥25 kg/m2 and the subsequent group with a BMI <25 kg/m2. Patients with a BMI ≥25 kg/m2 who underwent a TTE study had a sensitivity and specificity of 54 and 92%, respectively. On the contrary, patients with a BMI < 25 kg/m2 had a TTE sensitivity and specificity of 78 and 95%, respectively. Conclusions: Patients with a BMI <25 kg/m2 and a negative TTE should refrain from further diagnostic studies, with TEE strong clinical judgment is warranted. Patients with a BMI ≥ 25 kg/m2 may proceed directly to TEE as the initial study, possibly avoiding an additional study with a TTE.

  1. Echocardiography: pericardial thickening and constrictive pericarditis.

    Science.gov (United States)

    Schnittger, I; Bowden, R E; Abrams, J; Popp, R L

    1978-09-01

    A total of 167 patients with pericardial thickening noted on M node echocardiography were studied retrospectively. After the echocardiogram, 72 patients underwent cardiac surgery, cardiac catheterization or autopsy for various heart diseases; 96 patients had none of these procedures. In 49 patients the pericardium was directly visualized at surgery or autopsy; 76 percent of these had pericardial thickening or adhesions. In another 8 percent, pericardial adhesions were absent, but no comment had been made about the appearance of the pericardium itself. In the remaining 16 percent, no comment had been made about the pericardium or percardial space. Cardiac catheterization in 64 patients revealed 24 with hemodynamic findings of constrictive pericarditis or effusive constrictive disease. Seven echocardiographic patterns consistent with pericardial adhesions or pericardial thickening are described and related when possible to the subsequent findings at heart surgery or autopsy. The clinical diagnoses of 167 patients with pericardial thickening are presented. The hemodynamic diagnosis of constrictive pericardial disease was associated with the echocardiographic finding of pericardial thickening, but there were no consistent echocardiographic patterns of pericardial thickening diagnostic of constriction. However, certain other echocardiographic abnormalities of left ventricular posterior wall motion and interventricular septal motion and a high E-Fo slope were suggestive of constriction.

  2. Dynamic 3D echocardiography in virtual reality

    Directory of Open Access Journals (Sweden)

    Simoons Maarten L

    2005-12-01

    Full Text Available Abstract Background This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. Methods Three-dimensional echocardiographic data sets from 2 normal subjects and from 4 patients with a mitral valve pathological condition were included in the study. The three-dimensional data sets were acquired with the Philips Sonos 7500 echo-system and transferred to the BARCO (Barco N.V., Kortrijk, Belgium I-space. Ten independent observers assessed the 6 three-dimensional data sets with and without mitral valve pathology. After 10 minutes' instruction in the I-Space, all of the observers could use the virtual pointer that is necessary to create cut planes in the hologram. Results The 10 independent observers correctly assessed the normal and pathological mitral valve in the holograms (analysis time approximately 10 minutes. Conclusion this report shows that dynamic holographic imaging of three-dimensional echocardiographic data is feasible. However, the applicability and use-fullness of this technology in clinical practice is still limited.

  3. Minimally invasive cardiac surgery and transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Jha

    2014-01-01

    Full Text Available Improved cosmetic appearance, reduced pain and duration of post-operative stay have intensified the popularity of minimally invasive cardiac surgery (MICS; however, the increased risk of stroke remains a concern. In conventional cardiac surgery, surgeons can visualize and feel the cardiac structures directly, which is not possible with MICS. Transesophageal echocardiography (TEE is essential during MICS in detecting problems that require immediate correction. Comprehensive evaluation of the cardiac structures and function helps in the confirmation of not only the definitive diagnosis, but also the success of surgical treatment. Venous and aortic cannulations are not under the direct vision of the surgeon and appropriate positioning of the cannulae is not possible during MICS without the aid of TEE. Intra-operative TEE helps in the navigation of the guide wire and correct placement of the cannulae and allows real-time assessment of valvular pathologies, ventricular filling, ventricular function, intracardiac air, weaning from cardiopulmonary bypass and adequacy of the surgical procedure. Early detection of perioperative complications by TEE potentially enhances the post-operative outcome of patients managed with MICS.

  4. European Association of Echocardiography: Research Grant Programme.

    Science.gov (United States)

    Gargani, Luna; Muraru, Denisa; Badano, Luigi P; Lancellotti, Patrizio; Sicari, Rosa

    2012-01-01

    The European Society of Cardiology (ESC) offers a variety of grants/fellowships to help young professionals in the field of cardiological training or research activities throughout Europe. The number of grants has significantly increased in recent years with contributions from the Associations, Working Groups and Councils of the ESC. The European Association of Echocardiography (EAE) is a registered branch of the ESC and actively takes part in this initiative. One of the aims of EAE is to promote excellence in research in cardiovascular ultrasound and other imaging modalities in Europe. Therefore, since 2008, the EAE offers a Research Grant Programme to help young doctors to obtain research experience in a high standard academic centre (or similar institution oriented to clinical or pre-clinical research) in an ESC member country other than their own. This programme can be considered as a valorization of the geographical mobility as well as cultural exchanges and professional practice in the field of cardiovascular imaging. The programme has been very successful so far, therefore in 2012 the EAE has increased its offer to two grants of 25,000 euros per annum each.

  5. Transoesophageal echocardiography: What a neuroanaesthesiologist should know?

    Directory of Open Access Journals (Sweden)

    Minati Choudhury

    2015-01-01

    Full Text Available Transoesophageal echocardiography (TEE is a semi invasive imaging modality rapidly gained credence and popularity in the cardiothoracic centers worldwide by mid 1990s. It has also been found to be useful in some noncardiac surgical procedures, in particular in the management of neurosurgical patients and haemodynamically unstable patients in intensive care units (ICUs. The principal goal of basic transoesophageal echocardiographic examination encompass a broad range of anatomic imaging including the diagnosis of air embolism, causes of haemodynamic instability, ventricular size and function, volume status, and complications from invasive procedures, as well as the clinical impact or etiology of pulmonary dysfunction in ICU. TEE is relatively cheap and semi-invasive, but it should not be used as a stand-alone device but as a tool which provides data in addition to the data acquired from other forms of monitoring. The establishment of TEE in perioperative neuro anaesthetic care though recent, may result in a significant change in the role of the anaesthetsiologist who, using TEE can provide new information which may change the course and the outcome of surgical procedures.

  6. Echocardiography and cardiac resynchronisation therapy, friends or foes?

    Science.gov (United States)

    van Everdingen, W M; Schipper, J C; van 't Sant, J; Ramdat Misier, K; Meine, M; Cramer, M J

    2016-01-01

    Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

  7. Design of an integrated photo detector circuit for laser doppler blood flow monitoring

    NARCIS (Netherlands)

    Nieland, J.; Nieland, J.; van Kranenburg, H.; Wallinga, Hans; Serov, Alexander; Steenbergen, Wiendelt; de Mul, F.F.M.

    1999-01-01

    A method to measure the blood perfusion of tissue is to apply photons to tissue and measure the frequency shift of the Doppler shifted photons.. To avoid the use of fibers, a chip was designed which contains photodetectors and electronic circuitry to amplify the signal. This IC serves as an

  8. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  9. Impact of acquisition and interpretation on total inter-observer variability in echocardiography: results from the quality assurance program of the STAAB cohort study.

    Science.gov (United States)

    Morbach, Caroline; Gelbrich, Götz; Breunig, Margret; Tiffe, Theresa; Wagner, Martin; Heuschmann, Peter U; Störk, Stefan

    2018-02-14

    Variability related to image acquisition and interpretation is an important issue of echocardiography in clinical trials. Nevertheless, there is no broadly accepted standard method for quality assessment of echocardiography in clinical research reports. We present analyses based on the echocardiography quality-assurance program of the ongoing STAAB cohort study (characteristics and course of heart failure stages A-B and determinants of progression). In 43 healthy individuals (mean age 50 ± 14 years; 18 females), duplicate echocardiography scans were acquired and mutually interpreted by one of three trained sonographers and an EACVI certified physician, respectively. Acquisition (AcV), interpretation (InV), and inter-observer variability (IOV; i.e., variability between the acquisition-interpretation sequences of two different observers), were determined for selected M-mode, B-mode, and Doppler parameters. We calculated Bland-Altman upper 95% limits of absolute differences, implying that 95% of measurement differences were smaller/equal to the given value: e.g. LV end-diastolic volume (mL): 25.0, 25.0, 27.9; septal e' velocity (cm/s): 3.03, 1.25, 3.58. Further, 90, 85, and 80% upper limits of absolute differences were determined for the respective parameters. Both, acquisition and interpretation, independently and sizably contributed to IOV. As such, separate assessment of AcV and InV is likely to aid in echocardiography training and quality-assurance. Our results further suggest to routinely determine IOV in clinical trials as a comprehensive measure of imaging quality. The derived 95, 90, 85, and 80% upper limits of absolute differences are suggested as reproducibility targets of future studies, thus contributing to the international efforts of standardization in quality-assurance.

  10. Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.

    Science.gov (United States)

    Samad, Zainab; Minter, Stephanie; Armour, Alicia; Tinnemore, Amanda; Sivak, Joseph A; Sedberry, Brenda; Strub, Karen; Horan, Seanna M; Harrison, J Kevin; Kisslo, Joseph; Douglas, Pamela S; Velazquez, Eric J

    2016-03-01

    The management of aortic stenosis rests on accurate echocardiographic diagnosis. Hence, it was chosen as a test case to examine the utility of continuous quality improvement (CQI) approaches to increase echocardiographic data accuracy and reliability. A novel, multistep CQI program was designed and prospectively used to investigate whether it could minimize the difference in aortic valve mean gradients reported by echocardiography when compared with cardiac catheterization. The Duke Echo Laboratory compiled a multidisciplinary CQI team including 4 senior sonographers and MD faculty to develop a mapped CQI process that incorporated Intersocietal Accreditation Commission standards. Quarterly, the CQI team reviewed all moderate- or greater-severity aortic stenosis echocardiography studies with concomitant catheterization data, and deidentified individual and group results were shared at meetings attended by cardiologists and sonographers. After review of 2011 data, the CQI team proposed specific amendments implemented over 2012: the use of nontraditional imaging and Doppler windows as well as evaluation of aortic gradients by a second sonographer. The primary outcome measure was agreement between catheterization- and echocardiography-derived mean gradients calculated by using the coverage probability index with a prespecified acceptable echocardiography-catheterization difference of <10 mm Hg in mean gradient. Between January 2011 and January 2014, 2093 echocardiograms reported moderate or greater aortic stenosis. Among cases with available catheterization data pre- and post-CQI, the coverage probability index increased from 54% to 70% (P=0.03; 98 cases, year 2011; 70 cases, year 2013). The proportion of patients referred for invasive valve hemodynamics decreased from 47% pre-CQI to 19% post-CQI (P<0.001). A laboratory practice pattern that was amenable to reform was identified, and a multistep modification was designed and implemented that produced clinically

  11. Evidence of abnormal left ventricular function in patients with thalassaemia major: an echocardiography based study

    International Nuclear Information System (INIS)

    Sohail, M.; Hyder, S.N.

    2009-01-01

    Thalassaemia represent one of the most common single gene disorder causing a major public health problem in Pakistan. Nearly 100,000 people are born worldwide with this severe blood disorder every year. Over the last 3 decades, the development of regular transfusion therapy and iron chelation has dramatically improved the quality of life and transformed thalassaemia from a rapidly fatal disease to a chronic disease compatible with prolonged survival. Objective of this observational cross sectional study was to determine the effects of chronic anaemia and transfusional iron overload on the left ventricular function using Doppler echocardiography. This study was conducted in the Department of Paediatric Cardiology, The Children's Hospital and Institute of Child Health, Lahore, Pakistan from first April 2006 to September 30, 2007. The study comprised of 50 consecutive cases of beta-Thalassaemia major and 30 controls with normal haemoglobin and electrophoresis pattern. beta- Thalassaemia major patients were diagnosed on the basis of haemoglobin electrophoresis. Patients with any congenital or acquired heart disease, concurrent infective disorder and with history of cardiac surgery were excluded from the study. 2-D, M-mode and Doppler echocardiography was performed in all the study cases and controls. Statistical comparison of study cases and controls was conducted by using unpaired t-test. The age of the patients ranged from 2 years to 25 years with mean age of 9.65 years. Males were 34 (68%) and females were 16 (32%). None of the study cases was on regular chelation programme while 31 (62%) patients were on irregular chelation with single dose of intravenous desferrioxamine only at the time of blood transfusion. 19 (38%) of the patients had LV dysfunction in the form of isolated systolic dysfunction in 2 (4%), isolated diastolic dysfunction in 15 (30%) while global dysfunction in 2 (4%) of the patients. Left ventricular dimensions, stroke volume and E/A ratio were

  12. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  13. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  14. What every radiologist should know about paediatric echocardiography

    International Nuclear Information System (INIS)

    Sorantin, Erich; Heinzl, Bernd

    2014-01-01

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized

  15. What every radiologist should know about paediatric echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Sorantin, Erich, E-mail: erich.sorantin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria); Heinzl, Bernd [Division of Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria)

    2014-09-15

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized.

  16. Hand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography

    Directory of Open Access Journals (Sweden)

    Ramires Jose F

    2004-11-01

    Full Text Available Abstract Background Hand-carried ultrasound (HCU devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE, in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58. There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85, aortic regurgitation (kappa = 0.89, and tricuspid regurgitation (Kappa = 0.74. A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.

  17. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  18. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  19. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  20. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  1. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  2. Visualization of traumatic tricuspid insufficiency by three-dimensional echocardiography.

    Science.gov (United States)

    Nishimura, Kazuhisa; Okayama, Hideki; Inoue, Katsuji; Saito, Makoto; Nagai, Takayuki; Suzuki, Jun; Ogimoto, Akiyoshi; Ohtsuka, Tomoaki; Higaki, Jitsuo

    2010-01-01

    A 19-year-old male was admitted to the emergency room of our hospital after a motor vehicle accident. During his first physical examination, a holosystolic murmur was heard at the fourth left parasternal border. Transthoracic echocardiography showed severe tricuspid insufficiency, but the cause of tricuspid insufficiency was unclear. Therefore, three-dimensional echocardiography was performed and demonstrated flail anterior, posterior and septal leaflets of the tricuspid valve. The diagnosis was tricuspid insufficiency due to papillary muscle rupture secondary to chest blunt trauma. Surgical repair of the tricuspid valve was performed in this patient. After surgery, the signs and symptoms of right ventricular heart failure were relieved. In this case, three-dimensional echocardiography was very useful for the evaluation of spatial destruction of the tricuspid valve and papillary muscle. 2009 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  3. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  4. Recommendations for fetal echocardiography in twin pregnancy in 2016

    Directory of Open Access Journals (Sweden)

    Leszczyńska Katarzyna

    2016-01-01

    Full Text Available Progress in the fields of fetal cardiology and fetal surgery have been seen not only in singleton pregnancies but also in multiple pregnancies. Proper interpretation of prenatal echocardiography is critical to clinical decision making, family counseling and perinatal management for obstetricians, maternal fetal medicine specialists, neonatologists and pediatric cardiologists. Fetal echocardiography is one of the most challenging and time-consuming prenatal examinations to perform, especially in multiple gestations. Performing just the basic fetal exam in twin gestations may take an hour or more. Thus, it is not practical to perform this exam in all cases of multiple gestations. Therefore our review and recommendations are related to fetal echocardiography in twin gestation.

  5. Two-dimensional and Doppler echocardiographic findings in healthy non-sedated red-eared slider terrapins (Trachemys scripta elegans).

    Science.gov (United States)

    Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D

    2011-12-01

    Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.

  6. Stress echocardiography in valvular heart disease: a current appraisal.

    Science.gov (United States)

    Naji, Peyman; Patel, Krishna; Griffin, Brian P; Desai, Milind Y

    2015-03-01

    Stress echocardiography is increasingly used in the management of patients with valvular heart disease and can aid in evaluation, risk stratification and clinical decision making in these patients. Evaluation of symptoms, exercise capacity and changes in blood pressure can be done during the exercise portion of the test, whereas echocardiographic portion can reveal changes in severity of disease, pulmonary artery pressure and left ventricular function in response to exercise. These parameters, which are not available at rest, can have diagnostic and prognostic importance. In this article, we will review the indications and diagnostic implications, prognostic implications, and clinical impact of stress echocardiography in decision making and management of patients with valvular heart disease.

  7. Acute right ventricular dysfunction: real-time management with echocardiography.

    Science.gov (United States)

    Krishnan, Sundar; Schmidt, Gregory A

    2015-03-01

    In critically ill patients, the right ventricle is susceptible to dysfunction due to increased afterload, decreased contractility, or alterations in preload. With the increased use of point-of-care ultrasonography and a decline in the use of pulmonary artery catheters, echocardiography can be the ideal tool for evaluation and to guide hemodynamic and respiratory therapy. We review the epidemiology of right ventricular failure in critically ill patients; echocardiographic parameters for evaluating the right ventricle; and the impact of mechanical ventilation, fluid therapy, and vasoactive infusions on the right ventricle. Finally, we summarize the principles of management in the context of right ventricular dysfunction and provide recommendations for echocardiography-guided management.

  8. Echocardiography for patent ductus arteriosus including closure in adults.

    Science.gov (United States)

    Chugh, Reema; Salem, Morris M

    2015-01-01

    Patent ductus arteriosus (PDA) represents at least 5-10% of all congenital heart defects (CHDs) making it a very important commonly diagnosed lesion. Although spontaneous closure of the PDA occurs within 24 to 48 hours after birth in the majority, those children who do not have natural or surgical closure may have a persistent PDA into adulthood. The diagnosis is most often confirmed by echocardiography that also guides catheter-based interventions and surgeries. Echocardiography continues to be the most important tool in long-term follow-up of residua and sequelae. © 2014, Wiley Periodicals, Inc.

  9. Glare Spot Phase Doppler Anemometry

    Science.gov (United States)

    Hespel, Camille; Ren, Kuanfang; Gréhan, Gérard; Onofri, Fabrice

    2007-06-01

    The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index would be also interesting since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemometry which uses two large beams. In this case, the images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes in the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences between two signals, the distance and the intensity ratio of reflected and refracted parts can be obtained and they provide rich information about the particle diameter and its refractive index, as well as its velocity. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  10. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    DEFF Research Database (Denmark)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel

    2018-01-01

    ) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. RESULTS: 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D...... echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different...... between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r

  11. Association of heart failure hospitalizations with combined electrocardiography and echocardiography criteria for left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Gerdts, Eva; Okin, Peter M; Boman, Kurt

    2012-01-01

    The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain.......The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain....

  12. Exercise echocardiography in asymptomatic survivors of childhood cancer treated with anthracyclines

    DEFF Research Database (Denmark)

    Sieswerda, Elske; Kremer, Leontien C M; Vidmar, Suzanna

    2010-01-01

    BACKGROUND: Exercise echocardiography reveals abnormalities in asymptomatic childhood cancer survivors who previously have been treated with anthracyclines. We determined the added value of monitoring childhood cancer survivors with exercise echocardiography compared to monitoring with resting ec...

  13. Comparison of Hyperemic Impedance Echocardiography with Dobutamine Stress Echocardiography to Detect Inducible Myocardial Ischemia: A Pilot Study.

    Science.gov (United States)

    Patel, Jijibhoy J; Gupta, Ankur; Nanda, Navin C

    2016-03-01

    Stress echocardiography using exercise or pharmacological stressors is either contraindicated or associated with significant side effects in some patients. This pilot study was designed to evaluate a new technique, hyperemic impedance echocardiography (HIE). It is based on reactive coronary hyperemia when transient limb ischemia is induced by tourniquet inflation. We hypothesized that this physiologic coronary hyperemia can identify inducible myocardial ischemia by assessment of regional wall motion abnormalities on echocardiography when compared with dobutamine stress echocardiography (DSE). Twenty consecutive outpatients with suspected stable coronary artery disease (CAD) who underwent clinically indicated DSE were recruited for performance of HIE after informed consent was obtained. Standard graded dobutamine infusion protocol from 5 to 40 μg/kg per min was used for DSE. HIE was performed by inflating tourniquets at a pressure of 10 mmHg below the systolic blood pressure for 1 minute in three of four extremities at a time for total of four cycles. Echocardiography was performed immediately after the last rotating tourniquet deflation. DSE and HIE were classified as abnormal for development of new or worsening wall motion abnormality in at least one myocardial segment. Test characteristics were also determined for a subset of these patients (n = 12) who underwent clinically indicated coronary angiography. Hyperemic impedance echocardiography showed 86% sensitivity, 67% specificity, 86% positive predictive value, and 67% negative predictive value with a test accuracy of 80% to detect inducible myocardial wall motion abnormalities when compared with DSE. HIE also showed 83% sensitivity, 75% negative predictive value with a test accuracy of 66.7% for detection of significant (≥50% diameter stenosis) CAD on coronary angiography. In this pilot study, HIE was a feasible, safe, and promising method for detection of inducible myocardial ischemia by assessment of

  14. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  15. The Role of Focused Echocardiography in Pediatric Intensive Care: A Critical Appraisal

    Science.gov (United States)

    Gaspar, Heloisa Amaral; Morhy, Samira Saady

    2015-01-01

    Echocardiography is a key tool for hemodynamic assessment in Intensive Care Units (ICU). Focused echocardiography performed by nonspecialist physicians has a limited scope, and the most relevant parameters assessed by focused echocardiography in Pediatric ICU are left ventricular systolic function, fluid responsiveness, cardiac tamponade and pulmonary hypertension. Proper ability building of pediatric emergency care physicians and intensivists to perform focused echocardiography is feasible and provides improved care of severely ill children and thus should be encouraged. PMID:26605333

  16. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  17. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  18. A Wearable Transcranial Doppler Ultrasound Phased Array System.

    Science.gov (United States)

    Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2018-01-01

     Practical deficiencies related to conventional transcranial Doppler (TCD) sonography have restricted its use and applicability. This work seeks to mitigate several such constraints through the development of a wearable, electronically steered TCD velocimetry system, which enables noninvasive measurement of cerebral blood flow velocity (CBFV) for monitoring applications with limited operator interaction. A highly-compact, discrete prototype system was designed and experimentally validated through flow phantom and preliminary human subject testing. The prototype system incorporates a custom two-dimensional transducer array and multi-channel transceiver electronics, thereby facilitating acoustic beamformation via phased array operation. Electronic steering of acoustic energy enables algorithmic system controls to map Doppler power throughout the tissue volume of interest and localize regions of maximal flow. Multi-focal reception permits dynamic vessel position tracking and simultaneous flow velocimetry over the time-course of monitoring. Experimental flow phantom testing yielded high correlation with concurrent flowmeter recordings across the expected range of physiological flow velocities. Doppler power mapping has been validated in both flow phantom and preliminary human subject testing, resulting in average vessel location mapping times testing. A wearable prototype CBFV measurement system capable of autonomous vessel search and tracking has been presented. Although flow phantom and preliminary human validation show promise, further human subject testing is necessary to compare velocimetry data against existing commercial TCD systems. Additional human subject testing must also verify acceptable vessel search and tracking performance under a variety of subject populations and motion dynamics-such as head movement and ambulation.

  19. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  20. Exercise stress echocardiography in patients with valvular heart disease.

    Science.gov (United States)

    Sharma, Vishal; Newby, David E; Stewart, Ralph A H; Lee, Mildred; Gabriel, Ruvin; Van Pelt, Niels; Kerr, Andrew J

    2015-09-01

    Stress echocardiography is recommended for the assessment of asymptomatic patients with severe valvular heart disease (VHD) when there is discrepancy between symptoms and resting markers of severity. The aim of this study is to determine the prognostic value of exercise stress echocardiography in patients with common valve lesions. One hundred and fifteen patients with VHD (aortic stenosis (n=28); aortic regurgitation (n=35); mitral regurgitation, (n=26); mitral stenosis (n=26)), and age- and sex-matched controls (n=39) with normal ejection fraction underwent exercise stress echocardiography. The primary endpoint was a composite of death or hospitalization for heart failure. Asymptomatic VHD patients had lower exercise capacity than controls and 37% of patients achieved 60 mmHg) was associated with an increased risk of death or hospital admission (14% vs 1%, P<0.0001). The assessment of contractile reserve did not offer additional predictive value. In conclusion, an abnormal stress echocardiogram is associated with death and hospitalization with heart failure at 2 years. Stress echocardiography should be considered as part of the routine follow-up of all asymptomatic patients with VHD.

  1. Digital echocardiography and telemedicine applications in pediatric cardiology.

    Science.gov (United States)

    Sable, Craig

    2002-01-01

    Digital echocardiography offers several advantages over videotape, including easy review, comparison, storage, postprocessing, and sharing of studies, quantitative analysis, and superior resolution. Newer echocardiography systems can write digital data to computer hardware, whereas older systems require digitization of analog data. Clinical and digital data compression is required to reduce study size. Clinical compression has been validated in several adult studies and one pediatric study. JPEG and MPEG digital compression ratios of 26:1 and 200:1, respectively, approximate S-videotape quality. JPEG is the DICOM 3.0 standard and is ideal for short loops, serial comparisons, and quantitative analysis. MPEG (the motion picture standard) lends itself to digitization of video streams and may be more attractive to pediatric cardiologists. Options for data storage and transfer range from limited local review to multiple offline review stations linked by a wide-area network. Telemedicine expands the capabilities of digital echocardiography in a "store and forward" or "real-time" format. Real-time neonatal telecardiology is accurate, impacts patient care, is cost-effective, and does not increase utilization. Cost, increased reliance on sonographers' skills, lack of accepted standards, and legal, licensure, and billing issues are obstacles to widespread acceptance of digital echocardiography and telemedicine.

  2. Echocardiography in Infective Endocarditis: State of the Art.

    Science.gov (United States)

    Afonso, Luis; Kottam, Anupama; Reddy, Vivek; Penumetcha, Anirudh

    2017-10-25

    In this review, we examine the central role of echocardiography in the diagnosis, prognosis, and management of infective endocarditis (IE). 2D transthoracic echocardiography (TTE) and transesophageal echocardiography TEE have complementary roles and are unequivocally the mainstay of diagnostic imaging in IE. The advent of 3D and multiplanar imaging have greatly enhanced the ability of the imager to evaluate cardiac structure and function. Technologic advances in 3D imaging allow for the reconstruction of realistic anatomic images that in turn have positively impacted IE-related surgical planning and intervention. CT and metabolic imaging appear to be emerging as promising ancillary diagnostic tools that could be deployed in select scenarios to circumvent some of the limitations of echocardiography. Our review summarizes the indispensable and central role of various echocardiographic modalities in the management of infective endocarditis. The complementary role of 2D TTE and TEE are discussed and areas where 3D TEE offers incremental value highlighted. An algorithm summarizing a contemporary approach to the workup of endocarditis is provided and major societal guidelines for timing of surgery are reviewed.

  3. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran’s Electronic Health Record (EHR) System

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-01-01

    Background: Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. Aim: to determine the minimum data set of echocardiography reporting system to exchange with Iran’s electronic health record (EHR) system. Methods: First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients’ records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. Results: The highest degree of consensus was found for the following MDSs: patient’s name and family name (5), accepting doctor’s name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. Conclusions: To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran’s electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider. PMID:27147803

  4. Ecocardiografia de pacientes talassêmicos sem insuficiência cardíaca em tratamento com transfusões sanguíneas e quelação Echocardiography in thalassemic patients on blood transfusions and chelation without heart failure

    Directory of Open Access Journals (Sweden)

    Alexandre Rodrigues

    2013-01-01

    ção diastólica do ventrículo esquerdo sejam identificadas em pacientes assintomáticos com talassemia major.BACKGROUND: Patients with thalassemia major present chronic hemolysis and require regular blood transfusions which may cause iron overload cardiomyopathy and chronic heart failure. Hemochromatosis is characterized by excessive iron accumulation in tissues, and heart involvement is the main cause of death in patients with thalassemia. OBJECTIVE: The aim of this study was to evaluate cardiac structure and function by conventional Doppler echocardiography and tissue Doppler imaging in patients with TM and no clinical evidence of heart failure. METHODS: This is a prospective observational study including 18 patients with thalassemia major (TM receiving regular blood transfusion. To separately evaluate anemia and blood transfusion effects, two gender, age, weight, and height-matched control groups were included: one with healthy individuals (Healthy, n=18 and one with iron deficient anemia patients (Anemia, n=18. Statistical analysis was performed using ANOVA followed by Tukey's test or Kruskal-Wallis's and Dunn's test. RESULTS: The following echocardiographic variables presented significantly higher values in TM than the Anemia and Healthy groups: left atrium volume index (Healthy: 16.4±6.08; Anemia: 17.9±7.02; TM: 24.1±8.30 cm³/m²; mitral septal E/Em ratio (Healthy: 6.55±1.60; Anemia: 6.74±0.74; TM: 8.10±1.31; and duration of reverse pulmonary vein flow [Healthy: 74.0 (59.0-74.0; Anemia: 70.5 (67.0-74.0; TM: 111 (87.0-120 ms]. The mitral E/A ratio was higher in TM than Anemia (Healthy: 1.80±0.40; Anemia: 1.80±0.24; TM: 2.03±0.34. No differences were found in left ventricular structures and systolic function indexes. CONCLUSION: Conventional Doppler echocardiography and tissue Doppler allow changes in left ventricular diastolic function to be identified in asymptomatic patients with thalassemia major.

  5. Four-dimensional echocardiography area strain combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis.

    Science.gov (United States)

    Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li

    2017-09-01

    The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.

  6. Prediction of wall motion improvement after coronary revascularization in patients with postmyocardial infarction. Diagnostic value of dobutamine stress echocardiography and myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Waku, Sachiko; Ohkubo, Tomoyuki; Takada, Kiyoshi; Ishihara, Tadashi; Ohsawa, Nakaaki; Adachi, Itaru; Narabayashi, Isamu

    1997-01-01

    The diagnostic value of dobutamine stress echocardiography, myocardial contrast echocardiography and dipyridamole stress thallium-201 single photon emission computed tomography (SPECT) for predicting recovery of wall motion abnormality after revascularization was evaluated in 13 patients with postmyocardial infarction. Seventeen segments showed severe wall motion abnormalities before revascularization. Nine segments which had relatively good Tl uptake on delayed SPECT images despite severely abnormal wall motion were opacified during myocardial contrast echocardiography, and showed improved wall motion after revascularization. In contrast, three segments which had poor Tl uptake and severely abnormal wall motion were not opacified during myocardial contrast echocardiography, and showed no improvement in wall motion during dobutamine stress echocardiography and after revascularization. The following three findings were assumed to be signs of myocardial viability: good Tl uptake on delayed SPECT images, improved wall motion by dobutamine stress echocardiography, and positive opacification of the myocardium by myocardiai contrast echocardiography. Myocardial contrast echocardiography had the highest sensitivity (100%) and negative predictive value (100%). Delayed SPECT images had the highest specificity (100%) and positive predictive value (100%). Dobutamine stress echocardiography had a sensitivity of 83.0%, specificity of 80.0%, positive predictive value of 90.9%, and negative predictive value of 66.7%, respectively. Myocardial contrast echocardiography showed the lowest specificity (60.0%). The techniques of dobutamine stress echocardiography and SPECT, though noninvasive, may underestimate wall motion improvement after revascularization. Further examination by myocardial contrast echocardiography is recommended to assess myocardial viability for determining the indications for coronary revascularization in spite of its invasiveness. (author)

  7. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  8. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  9. A model for post-occlusive reactive hyperemia as measured with laser-Doppler perfusion monitoring

    NARCIS (Netherlands)

    de Mul, FFM; Morales, F; Smit, AJ; Graaff, R

    To facilitate the quantitative analysis of post-occlusive reactive fiyper emia (POR11), measured with laser-Doppler perfusion monitoring (LDPM) on extremities, we present a flow model for the dynamics of the perfusion of the tissue during PORH, based on three parameters: two time constants (tau(1)

  10. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  11. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  12. Prognosis of Light Chain Amyloidosis With Preserved LVEF: Added Value of 2D Speckle-Tracking Echocardiography to the Current Prognostic Staging System.

    Science.gov (United States)

    Barros-Gomes, Sergio; Williams, Brittney; Nhola, Lara F; Grogan, Martha; Maalouf, Joseph F; Dispenzieri, Angela; Pellikka, Patricia A; Villarraga, Hector R

    2017-04-01

    This study evaluated whether 2-dimensional speckle-tracking echocardiography (2D-STE) has incremental value for prognosis over traditional clinical, echocardiographic, and serological markers-with main focus on the current prognostic staging system-in light-chain (AL) amyloidosis patients with preserved left ventricular ejection fraction. Cardiac amyloidosis (CA) is the major determinant of outcome in AL amyloidosis. The current prognostic staging system is based primarily on serum levels of cardiac troponin T (cTnT), N-terminal pro-B-type natriuretic peptide (NT-proBNP), and free light chain differential (FLC-diff). Consecutive patients with biopsy-proven AL amyloidosis and left ventricular ejection fraction ≥55% were divided into group 1 with CA (n = 63) and group 2 without CA (n = 87). Global longitudinal strain (GLS) by 2D-STE was performed with Vivid E9 (GE Healthcare Co., Milwaukee, Wisconsin) and syngo Velocity Vector Imaging (VVI) software (Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania) (GLS GE and GLS VVI , respectively). Thirty-two deaths (51%) occurred in group 1 and 13 (15%) in group 2 (p ≤ 0.001). Group 1 had thicker walls, lower early diastolic tissue Doppler velocity at septal mitral annulus, and greater left ventricular mass, left atrial volume, glomerular filtration rate, FLC-diff, cTnT, and NT-proBNP (p value over cTnT, NT-proBNP, and FLC-diff. For survival analysis limited to group 2 (non-CA), GLS GE and GLS VVI both predicted all-cause mortality (GLS GE HR: 1.23; 95% CI: 1.03 to 1.47 [p = 0.02]; GLS VVI HR: 1.22; 95% CI: 1.01 to 1.49 [p = 0.04], respectively). 2D-STE predicted outcome and provided incremental prognostic information over the current prognostic staging system, especially in the group without CA. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Improvement of Automated Identification of the Heart Wall in Echocardiography by Suppressing Clutter Component

    Science.gov (United States)

    Takahashi, Hiroki; Hasegawa, Hideyuki; Kanai, Hiroshi

    2013-07-01

    For the facilitation of analysis and elimination of the operator dependence in estimating the myocardial function in echocardiography, we have previously developed a method for automated identification of the heart wall. However, there are misclassified regions because the magnitude-squared coherence (MSC) function of echo signals, which is one of the features in the previous method, is sensitively affected by the clutter components such as multiple reflection and off-axis echo from external tissue or the nearby myocardium. The objective of the present study is to improve the performance of automated identification of the heart wall. For this purpose, we proposed a method to suppress the effect of the clutter components on the MSC of echo signals by applying an adaptive moving target indicator (MTI) filter to echo signals. In vivo experimental results showed that the misclassified regions were significantly reduced using our proposed method in the longitudinal axis view of the heart.

  14. Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse

    Science.gov (United States)

    Adair, Henry S., III

    1998-07-01

    Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.

  15. Multi-view 3D echocardiography compounding based on feature consistency

    Science.gov (United States)

    Yao, Cheng; Simpson, John M.; Schaeffter, Tobias; Penney, Graeme P.

    2011-09-01

    Echocardiography (echo) is a widely available method to obtain images of the heart; however, echo can suffer due to the presence of artefacts, high noise and a restricted field of view. One method to overcome these limitations is to use multiple images, using the 'best' parts from each image to produce a higher quality 'compounded' image. This paper describes our compounding algorithm which specifically aims to reduce the effect of echo artefacts as well as improving the signal-to-noise ratio, contrast and extending the field of view. Our method weights image information based on a local feature coherence/consistency between all the overlapping images. Validation has been carried out using phantom, volunteer and patient datasets consisting of up to ten multi-view 3D images. Multiple sets of phantom images were acquired, some directly from the phantom surface, and others by imaging through hard and soft tissue mimicking material to degrade the image quality. Our compounding method is compared to the original, uncompounded echocardiography images, and to two basic statistical compounding methods (mean and maximum). Results show that our method is able to take a set of ten images, degraded by soft and hard tissue artefacts, and produce a compounded image of equivalent quality to images acquired directly from the phantom. Our method on phantom, volunteer and patient data achieves almost the same signal-to-noise improvement as the mean method, while simultaneously almost achieving the same contrast improvement as the maximum method. We show a statistically significant improvement in image quality by using an increased number of images (ten compared to five), and visual inspection studies by three clinicians showed very strong preference for our compounded volumes in terms of overall high image quality, large field of view, high endocardial border definition and low cavity noise.

  16. Multi-view 3D echocardiography compounding based on feature consistency

    International Nuclear Information System (INIS)

    Yao Cheng; Schaeffter, Tobias; Penney, Graeme P; Simpson, John M

    2011-01-01

    Echocardiography (echo) is a widely available method to obtain images of the heart; however, echo can suffer due to the presence of artefacts, high noise and a restricted field of view. One method to overcome these limitations is to use multiple images, using the 'best' parts from each image to produce a higher quality 'compounded' image. This paper describes our compounding algorithm which specifically aims to reduce the effect of echo artefacts as well as improving the signal-to-noise ratio, contrast and extending the field of view. Our method weights image information based on a local feature coherence/consistency between all the overlapping images. Validation has been carried out using phantom, volunteer and patient datasets consisting of up to ten multi-view 3D images. Multiple sets of phantom images were acquired, some directly from the phantom surface, and others by imaging through hard and soft tissue mimicking material to degrade the image quality. Our compounding method is compared to the original, uncompounded echocardiography images, and to two basic statistical compounding methods (mean and maximum). Results show that our method is able to take a set of ten images, degraded by soft and hard tissue artefacts, and produce a compounded image of equivalent quality to images acquired directly from the phantom. Our method on phantom, volunteer and patient data achieves almost the same signal-to-noise improvement as the mean method, while simultaneously almost achieving the same contrast improvement as the maximum method. We show a statistically significant improvement in image quality by using an increased number of images (ten compared to five), and visual inspection studies by three clinicians showed very strong preference for our compounded volumes in terms of overall high image quality, large field of view, high endocardial border definition and low cavity noise.

  17. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  18. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  19. Spectral Doppler findings in a rare case of acute compartment syndrome following leg burn

    Directory of Open Access Journals (Sweden)

    Omer A. Mahmoud

    2018-04-01

    Full Text Available Acute compartment syndrome (ACS is an orthopedic emergency condition, which is rarely attributed to burns. It occurs when pressure in an enclosed space rises to a point where it reduces blood flow and impairs tissue perfusion. Its consequences often lead to ischemia and possible necrosis within that space. Until now, the use of Doppler assessment to explore different types of compartment syndrome has yielded contradictory findings. Here, we present a significant increase of blood flow velocity in the arteries proximal to the burned area. Thus, the combination of Duplex ultrasound results with clinical findings will help vascular surgeons to make immediate decision to perform fasciotomy. Keywords: Compartment syndrome, Spectral Doppler

  20. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  1. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  2. The Interplay between Fasting Glucose, Echocardiography, and Biomarkers

    DEFF Research Database (Denmark)

    Pareek, Manan

    preventive setting, remains incomplete. Phenotypical heterogeneity may be even greater among subjects with hyperglycemic conditions, i.e., prediabetes and diabetes, which is worrisome, given the dramatic global rise in mean fasting glucose levels, and the strong association with adverse cardiovascular...... subclinical changes to manifest disease include echocardiography and circulating biomarkers. Objectives 1) To examine whether greater fasting plasma glucose (FPG) levels were associated with left ventricular mass (LVM), geometric pattern, diastolic function, and concentrations of N-terminal prohormone...... from the three categories defined by baseline FPG, i.e., normal fasting glucose, impaired fasting glucose, and diabetes, including use of anti-diabetic medication. Blood samples for cardiovascular biomarker assessments were drawn at the time of echocardiography and kept frozen until analysis. Outcome...

  3. On-Orbit Prospective Echocardiography on International Space Station

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2010-01-01

    A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

  4. Three-dimensional adult echocardiography: where the hidden dimension helps.

    Science.gov (United States)

    Mor-Avi, Victor; Sugeng, Lissa; Lang, Roberto M

    2008-05-01

    The introduction of three-dimensional (3D) imaging and its evolution from slow and labor-intense off-line reconstruction to real-time volumetric imaging is one of the most significant developments in ultrasound imaging of the heart of the past decade. This imaging modality currently provides valuable clinical information that empowers echocardiography with new levels of confidence in diagnosing heart disease. One major advantage of seeing the additional dimension is the improvement in the accuracy of the evaluation of cardiac chamber volumes by eliminating geometric modeling and the errors caused by foreshortened views. Another benefit of 3D imaging is the realistic views of cardiac valves capable of demonstrating numerous pathologies in a unique, noninvasive manner. This article reviews the major technological developments in 3D echocardiography and some of the recent literature that has provided the scientific basis for its clinical use.

  5. Elevational spatial compounding for enhancing image quality in echocardiography

    OpenAIRE

    Perperidis, Antonios; McDicken, Norman; MacGillivray, Tom; Anderson, Tom

    2016-01-01

    Introduction Echocardiography is commonly used in clinical practice for the real-time assessment of cardiac morphology and function. Nevertheless, due to the nature of the data acquisition, cardiac ultrasound images are often corrupted by a range of acoustic artefacts, including acoustic noise, speckle and shadowing. Spatial compounding techniques have long been recognised for their ability to suppress common ultrasound artefacts, enhancing the imaged cardiac structures. However, they require...

  6. Portopulmonary hypertension: Improved detection using CT and echocardiography in combination

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Anand [Royal Brompton and Harefield NHS Foundation Trust, Department of Radiology, London (United Kingdom); Loveridge, Robert; Bernal, William; Willars, Christopher; Wendon, Julia A.; Auzinger, Georg [King' s College Hospital NHS Foundation Trust, The Institute of Liver Studies, King' s Health Partners, King' s College London, London (United Kingdom); Bosanac, Diana; Stefanidis, Konstantinos; Desai, Sujal R. [King' s College Hospital NHS Foundation Trust, Department of Radiology, King' s Health Partners, King' s College London, London (United Kingdom)

    2014-10-15

    To establish the relationship between CT signs of pulmonary hypertension and mean pulmonary artery pressure (mPAP) in patients with liver disease, and to determine the additive value of CT in the detection of portopulmonary hypertension in combination with transthoracic echocardiography. Forty-nine patients referred for liver transplantation were retrospectively reviewed. Measured CT signs included the main pulmonary artery/ascending aorta diameter ratio (PA/AA{sub meas}) and the mean left and right main PA diameter (RLPA{sub meas}). Enlargement of the pulmonary artery compared to the ascending aorta was also assessed visually (PA/AA{sub vis}). CT measurements were correlated with right-sided heart catheter-derived mPAP. The ability of PA/AA{sub vis} combined with echocardiogram-derived right ventricular systolic pressure (RVSP) to detect portopulmonary hypertension was tested with ROC analysis. There were moderate correlations between mPAP and both PA/AA{sub meas} and RLPA{sub meas} (r{sub s} = 0.41 and r{sub s} = 0.42, respectively; p < 0.005). Compared to transthoracic echocardiography alone (AUC = 0.59, p = 0.23), a diagnostic algorithm incorporating PA/AA{sub vis} and transthoracic echocardiography-derived RVSP improved the detection of portopulmonary hypertension (AUC = 0.8, p < 0.0001). CT contributes to the non-invasive detection of portopulmonary hypertension when used in a diagnostic algorithm with transthoracic echocardiography. CT may have a role in the pre-liver transplantation triage of patients with portopulmonary hypertension for right-sided heart catheterisation. (orig.)

  7. Portopulmonary hypertension: Improved detection using CT and echocardiography in combination

    International Nuclear Information System (INIS)

    Devaraj, Anand; Loveridge, Robert; Bernal, William; Willars, Christopher; Wendon, Julia A.; Auzinger, Georg; Bosanac, Diana; Stefanidis, Konstantinos; Desai, Sujal R.

    2014-01-01

    To establish the relationship between CT signs of pulmonary hypertension and mean pulmonary artery pressure (mPAP) in patients with liver disease, and to determine the additive value of CT in the detection of portopulmonary hypertension in combination with transthoracic echocardiography. Forty-nine patients referred for liver transplantation were retrospectively reviewed. Measured CT signs included the main pulmonary artery/ascending aorta diameter ratio (PA/AA meas ) and the mean left and right main PA diameter (RLPA meas ). Enlargement of the pulmonary artery compared to the ascending aorta was also assessed visually (PA/AA vis ). CT measurements were correlated with right-sided heart catheter-derived mPAP. The ability of PA/AA vis combined with echocardiogram-derived right ventricular systolic pressure (RVSP) to detect portopulmonary hypertension was tested with ROC analysis. There were moderate correlations between mPAP and both PA/AA meas and RLPA meas (r s = 0.41 and r s = 0.42, respectively; p vis and transthoracic echocardiography-derived RVSP improved the detection of portopulmonary hypertension (AUC = 0.8, p < 0.0001). CT contributes to the non-invasive detection of portopulmonary hypertension when used in a diagnostic algorithm with transthoracic echocardiography. CT may have a role in the pre-liver transplantation triage of patients with portopulmonary hypertension for right-sided heart catheterisation. (orig.)

  8. Dobutamine stress echocardiography in healthy adult male rats

    Directory of Open Access Journals (Sweden)

    Couet Jacques

    2005-10-01

    Full Text Available Abstract Background Dobutamine stress echocardiography is used to investigate a wide variety of heart diseases in humans. Dobutamine stress echocardiography has also been used in animal models of heart disease despite the facts that the normal response of healthy rat hearts to this type of pharmacological stress testing is unknown. This study was performed to assess this normal response. Methods 15 normal adult male Wistar rats were evaluated. Increasing doses of dobutamine were infused intravenously under continuous imaging of the heart by a 12 MHz ultrasound probe. Results Dobutamine stress echocardiography reduced gradually LV diastolic and systolic dimensions. Ejection fraction increased by a mean of +24% vs. baseline. Heart rate increased progressively without reaching a plateau. Changes in LV dimensions and ejection fraction reached a plateau after a mean of 4 minutes at a constant infusion rate. Conclusion DSE can be easily performed in rats. The normal response is an increase in heart rate and ejection fraction and a decrease in LV dimensions. A plateau in echocardiographic measurements is obtained after 4 minutes of a constant infusion rate in most animals.

  9. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  10. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  11. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  12. Doppler-echocardiographic assessment of valvular regurgitation in healthy young subjects

    International Nuclear Information System (INIS)

    Filcheva, K.; Gochev, D.; Petrovski, P.; Kotsev, P.

    1995-01-01

    The study covers 300 clinically healthy, randomly selected young subjects, aged 17 to 21 years. The incidence and characteristic features of the valvular regurgitations are assayed by means of pulsed and continuous transthoracic Doppler echocardiography. Valvular insufficiency is registered in total of 198 cases (66%). Regurgitation of single valve is observed in 122 cases (61%), regurgitation of two valves - in 70 (36%) and three valves - in six (3%). Right-sided regurgitations (tricuspid, pulmonic and a combination of both) are detected in 156 subjects, and left-sided (mitral and/or aortic) in twenty-six of which only one regurgitation of the aortic valve. There is a definite tendency of the first two to prevail at a ratio 6:1. A constellation of various anatomical and physiological factors are considered as a likely underlying cause. Whenever atrio-ventricular valves are examined (the mitral one in particular), it is necessary that the regurgitation jet involves over 50% of systole in order to avoid hyperdiagnostics and the so-called 'Doppler's disease'. 14 refs., 1 tab., 2 figs. (author)

  13. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    Science.gov (United States)

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (page of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  14. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  15. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  16. Retrospective analysis of transthoracic echocardiography about the failure of transcather closure of ventricular septal defect

    International Nuclear Information System (INIS)

    Zhang Yigang; Li Shijie; Liu Ru; Li Zhihong; Fu Qiang

    2008-01-01

    Objective: To evaluate the value of echocardiography in investigation the failure of interventional therapy of VSDs and to increase the successful rate. Methods: 15 cases with failure of VSD closure through interventional approach were undertaken measurement of major parameters of the defect on left ventriculography and then followed by Philips 5500 color Doppler US for repeated multi-direction tangential measuring of the size, morphologic change, relation with peripheral structure and individual valvular regurgitation. Results: (1) Marginal membranous VSD 10 eases; membranance aneurysm 8 cases, ≥ 2 outlets 6 cases. Width of basal part of membranous aneurysm was 8-18 (10±2) mm with depth of 3 10 (6±2) mm, distance from aortic valve was 0-6 (2±1) mm and from tricuspid valve was 2-5 (2±1) mm; associated with slight tricuspid valvular regurgitation. Aortic valvular regurgitation 5 cases showed slight to mild amount and without membranous aneurysm occurred in 2 cases. (2) Intracristal VSD 5 cases showed the size of defect as 6-10 (7±1) mm, with distances of 2-3 (1±0.8) mm from pulmonary valve and 1-2 (1±0.6) mm from aortic valve associated with slight regurgitation in 4 cases, slight tricuspid valvular regurgitation in 5 eases and aortic valvular prolapse in 4 cases. Conclusions: Many factors can influence the direction tangential continuous scanning should be taken for accurate localization and measurement of VSD in order to select the very sight occludor providing high successful rate of occlusion and long term efficacy. (authors)

  17. Three-Dimensional Echocardiography-Derived Non-Invasive Right Ventricular Pressure-Volume Analysis.

    Science.gov (United States)

    Huang, Kuan-Chih; Lin, Lian-Yu; Hwang, Juey-Jen; Lin, Lung-Chun

    2017-09-01

    In patients with pulmonary hypertension, repeated evaluations of right ventricular (RV) function are still required for clinical decision making, but the invasive nature of current pressure-volume analysis makes conducting regular follow-ups in a clinical setting infeasible. We enrolled 12 patients with pulmonary arterial hypertension (PAH) and 10 with pulmonary venous hypertension (PVH) May 2016-October 2016. All patients underwent a clinically indicated right heart catheterization (RHC), from which the yielded right ventricular pressure recordings were conjugated with RV volume by 3-D echocardiography to generate a pressure-volume loop. A continuous-wave Doppler envelope of tricuspid regurgitation was transformed into a pressure gradient recording by the simplified Bernoulli equation, and then a systolic pressure gradient-volume (PG-V) diagram was generated from similar methods. The area enclosed by the pressure-volume loop was calculated to represent semi-invasive right ventricular stroke work (RVSW RHC ). The area between the PG-V diagram and x-axis was calculated to estimate non-invasive RVSW (RVSW echo ). Patients with PAH have higher RV pressure, lower pulmonary arterial wedge pressure and larger RV volume that was contributed by the dilation of RV mid-cavity minor dimension. We found no significant difference of traditional parameters between these two groups, but RVSW values were significantly higher in PAH patients. The RVSW values of these two methods were significantly correlated by the equation RVSW echo  = 0.8447 RVSW RHC  + 129.38 (R 2  = 0.9151, p rights reserved.

  18. A follow-up study of neonatal interatrial shunt with echocardiography until twelve to fifteen months of age.

    Science.gov (United States)

    Ho, Chi-Lin; Jan, Sheng-Ling; Lin, Ming-Chih; Fu, Yun-Ching

    2008-12-01

    To assess the incidence and natural history of full-term neonates with interatrial shunt (IAS). A follow-up study of 1389 neonates who received screening echocardiography between 2003 and 2006. Babies with IAS at 2 to 4 days of life underwent follow-up echocardiography at 2 to 4 months, 6 to 9 months and 12 to 15 months of age until closure of IAS. The ratio of IAS was 68.3% initially. No significant demographic differences were identified between infants with and without initial IAS. Among 949 neonates with initial IAS, 84.5% infants had a left-to-right interatrial shunt, 13.5% had bidirectional shunt and 2% had predominantly right-to-left shunt. The persistence rate of IAS at 12 to 15 months of age was 3.8% (44/1166). The initial size of IAS ranged from 1.2 to 7.7mm (4.3+/-1.1 mm) detected by color Doppler flow mapping and cases were divided into three groups: small ( or =8 mm). There were 74.6% infants in the small group and 25.4% in the medium group initially. The neonates in the initial small group would always see their IAS close or else they would remain in the small group. Those in the final medium and large size groups always came from the initial medium group. The late closure rate of IAS was 93.9% of infants with initial IAS. The closure curves of initial small and medium sized groups were significantly different, and their late closure rates were 95.1% and 90.4%, respectively. IAS was very common during early neonatal stage, but most cases would close after 1 year. The late closure rate of initial IAS was different if using a cutpoint of 5 mm.

  19. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  20. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  1. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  2. Aortic coarctation diagnosed by renal Doppler flow patterns in a hypertensive young patient: a case report

    International Nuclear Information System (INIS)

    Sari, S.; Kara, K.; Verim, S.

    2012-01-01

    Full text: Introduction: Aortic coarctation is a congenital malformation, which can cause systemic hypertension and subsequent complications, and causes of secondary hypertension, affecting in differential pressures in the upper and lower extremities. Because hypertension is caused by aortic coarctation, tends to be resistant to medical therapy, early recognition and surgical rectification are important. Objectives and tasks: In this article, we aimed to point out that renal Doppler sonography is a beneficial and frequently used to evaluate secondary hypertension, if there are bilateral tardus-parvus wave patterns are detected. Thus, bilateral renal artery stenosis, aortic stenosis, and coarctation should be considered in this condition. Materials and methods: A 23-year-old male who has six-month history of hypertension. He was referred by a cardiologist for investigation of his secondary hypertension. There was an ascending aortic dilatation, left ventricular hypertrophy in his echocardiography. Results: The patient's blood pressure was measured as 160/90 mm Hg in his both arms. Renal Doppler sonography was performed to identify the potential cause of secondary hypertension, specifically renal artery stenosis, after tardus-parvus pulse waves were noted in both renal intralobar-arteries. Aortic coarctation is suspected and then a chest computed tomography (CT) was performed to evaluate supra-diaphragmatic vessel abnormalities. The CT exposed a stenotic lesion in the isthmus of the aorta. The patient was transferred to cardiovascular surgery department for treatment. Conclusion: Careful physical examination should be performed in all hypertensive patients. If bilateral tardus-parvus wave pattern are seen in patients who has been referred for Doppler evaluation on suspicion of renovascular hypertension, aortic coarctation should be considered as differential diagnosis

  3. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    International Nuclear Information System (INIS)

    Gimpel, Charlotte; Pohl, Martin; Jung, Bernd A.; Jung, Sabine; Brado, Johannes; Odening, Katja E.; Schwendinger, Daniel; Burkhardt, Barbara; Geiger, Julia; Arnold, Raoul

    2017-01-01

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V E ), late diastolic (V A ) and peak systolic (V S ) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz base -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz mid -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz apex -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr base -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr mid -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr apex -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  4. Magnetic resonance tissue phase mapping demonstrates altered left ventricular diastolic function in children with chronic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Gimpel, Charlotte; Pohl, Martin [Medical Center - University of Freiburg, Department of General Pediatrics, Adolescent Medicine and Neonatology, Center for Pediatrics, Freiburg (Germany); Jung, Bernd A. [Inselspital Bern, Institute of Diagnostic, Interventional and Pediatric Radiology, Bern (Switzerland); Jung, Sabine [Medical Center - University of Freiburg, Department of Nuclear Medicine, Freiburg (Germany); Brado, Johannes; Odening, Katja E. [University Heart Center Freiburg, Department of Cardiology and Angiology I, Freiburg (Germany); Schwendinger, Daniel [University Children' s Hospital Zurich, Zurich (Switzerland); Burkhardt, Barbara [University Children' s Hospital Zurich, Pediatric Heart Center, Zurich (Switzerland); Geiger, Julia [University Children' s Hospital Zurich, Department of Radiology, Zurich (Switzerland); Northwestern University, Department of Radiology, Chicago, IL (United States); Arnold, Raoul [University Hospital Heidelberg, Department of Pediatric and Congenital Cardiology, Heidelberg (Germany)

    2017-02-15

    Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. Patients and controls (age: 8 years - 20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (V{sub E}), late diastolic (V{sub A}) and peak systolic (V{sub S}) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vz{sub base} -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vz{sub mid} -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vz{sub apex} -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vr{sub base} -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vr{sub mid} -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vr{sub apex} -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs. (orig.)

  5. Transesophageal echocardiography in the assessment of coronary arteries

    International Nuclear Information System (INIS)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M.

    1993-01-01

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author)

  6. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  7. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  8. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  9. [Pilot study of echocardiographic studies using color- and pulsed-wave spectral Doppler methods in blue-crowned amazons (Amazona ventralis) and blue-fronted amazons (Amazona a. aestiva)].

    Science.gov (United States)

    Pees, M; Straub, J; Schumacher, J; Gompf, R; Krautwald-Junghanns, M E

    2005-02-01

    Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.

  10. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  11. Exercise right heart catheterization for pulmonary hypertension identified on screening echocardiography in adult survivors of childhood cancer: A report from the St. Jude Lifetime Cohort.

    Science.gov (United States)

    Armstrong, Gregory T; Tolle, James J; Piana, Robert; Santucci, Aimee; Leathers, James; Ness, Kirsten K; Mulrooney, Daniel A; Green, Daniel M; Joshi, Vijaya M; Robison, Leslie L; Hudson, Melissa M; Lenihan, Daniel

    2018-01-01

    Pulmonary hypertension, determined noninvasively by tricuspid regurgitant jet velocity on Doppler echocardiography, was previously identified in 25% of long-term survivors who received chest-directed radiotherapy. To validate noninvasively defined pulmonary hypertension, survivors (mean age 48 years), exposed to chest radiotherapy, underwent right heart catheterization with planned cardiopulmonary exercise testing during catheterization. Eight participants had an elevated mean pulmonary artery pressure at rest (≥25 mm Hg) or with subsequent exercise (>30 mm Hg), evidence of hemodynamically confirmed pulmonary hypertension by right heart catheterization. Cardiopulmonary exercise testing further defined the magnitude and etiology of cardiopulmonary limitations in this life-threatening late effect. © 2017 Wiley Periodicals, Inc.

  12. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  13. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  14. Inline Ultrasonic Rheometry by Pulsed Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  15. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  16. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  17. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  18. Validation of noninvasive indices of global systolic function in patients with normal and abnormal loading conditions: a simultaneous echocardiography pressure-volume catheterization study.

    Science.gov (United States)

    Yotti, Raquel; Bermejo, Javier; Benito, Yolanda; Sanz-Ruiz, Ricardo; Ripoll, Cristina; Martínez-Legazpi, Pablo; del Villar, Candelas Pérez; Elízaga, Jaime; González-Mansilla, Ana; Barrio, Alicia; Bañares, Rafael; Fernández-Avilés, Francisco

    2014-01-01

    Noninvasive indices based on Doppler echocardiography are increasingly used in clinical cardiovascular research to evaluate left ventricular global systolic chamber function. Our objectives were to clinically validate ultrasound-based methods of global systolic chamber function to account for differences between patients in conditions of abnormal load, and to assess their sensitivity to load confounders. Twenty-seven patients (8 dilated cardiomyopathy, 10 normal ejection fraction, and 9 end-stage liver disease) underwent simultaneous echocardiography and left heart catheterization with pressure-conductance instrumentation. The reference index, maximal elastance (Emax), was calculated from pressure-volume loop data obtained during acute inferior vena cava occlusion. A wide range of values were observed for left ventricular systolic chamber function (Emax: 2.8±1.0 mm Hg/mL), preload, and afterload. Among the noninvasive indices tested, the peak ejection intraventricular pressure difference showed the best correlation with Emax (R=0.75). A significant but weaker correlation with Emax was observed for ejection fraction (R=0.41), midwall fractional shortening (R=0.51), global circumferential strain (R=-0.53), and strain rate (R=-0.46). Longitudinal strain and strain rate failed to correlate with Emax, as did noninvasive single-beat estimations of this index. Principal component and multiple regression analyses demonstrated that peak ejection intraventricular pressure difference was less sensitive to load, whereas ejection fraction and longitudinal strain and strain rate were heavily influenced by afterload. Current ultrasound methods have limited accuracy to characterize global left ventricular systolic chamber function in a given patient. The Doppler-derived peak ejection intraventricular pressure difference should be preferred for this purpose because it best correlates with the reference index and is more robust in conditions of abnormal load.

  19. THD Doppler procedure for hemorrhoids: the surgical technique.

    Science.gov (United States)

    Ratto, C

    2014-03-01

    Transanal hemorrhoidal dearterialization (THD) is an effective treatment for hemorrhoidal disease. The ligation of hemorrhoidal arteries (called "dearterialization") can provide a significant reduction of the arterial overflow to the hemorrhoidal piles. Plication of the redundant rectal mucosa/submucosa (called "mucopexy") can provide a repositioning of prolapsing tissue to the anatomical site. In this paper, the surgical technique and perioperative patient management are illustrated. Following adequate clinical assessment, patients undergo THD under general or spinal anesthesia, in either the lithotomy or the prone position. In all patients, distal Doppler-guided dearterialization is performed, providing the selective ligation of hemorrhoidal arteries identified by Doppler. In patients with hemorrhoidal/muco-hemorrhoidal prolapse, the mucopexy is performed with a continuous suture including the redundant and prolapsing mucosa and submucosa. The description of the surgical procedure is complemented by an accompanying video (see supplementary material). In long-term follow-up, there is resolution of symptoms in the vast majority of patients. The most common complication is transient tenesmus, which sometimes can result in rectal discomfort or pain. Rectal bleeding occurs in a very limited number of patients. Neither fecal incontinence nor chronic pain should occur. Anorectal physiology parameters should be unaltered, and anal sphincters should not be injured by following this procedure. When accurately performed and for the correct indications, THD is a safe procedure and one of the most effective treatments for hemorrhoidal disease.

  20. Fine-grained information extraction from German transthoracic echocardiography reports.

    Science.gov (United States)

    Toepfer, Martin; Corovic, Hamo; Fette, Georg; Klügl, Peter; Störk, Stefan; Puppe, Frank

    2015-11-12

    Information extraction techniques that get structured representations out of unstructured data make a large amount of clinically relevant information about patients accessible for semantic applications. These methods typically rely on standardized terminologies that guide this process. Many languages and clinical domains, however, lack appropriate resources and tools, as well as evaluations of their applications, especially if detailed conceptualizations of the domain are required. For instance, German transthoracic echocardiography reports have not been targeted sufficiently before, despite of their importance for clinical trials. This work therefore aimed at development and evaluation of an information extraction component with a fine-grained terminology that enables to recognize almost all relevant information stated in German transthoracic echocardiography reports at the University Hospital of Würzburg. A domain expert validated and iteratively refined an automatically inferred base terminology. The terminology was used by an ontology-driven information extraction system that outputs attribute value pairs. The final component has been mapped to the central elements of a standardized terminology, and it has been evaluated according to documents with different layouts. The final system achieved state-of-the-art precision (micro average.996) and recall (micro average.961) on 100 test documents that represent more than 90 % of all reports. In particular, principal aspects as defined in a standardized external terminology were recognized with f 1=.989 (micro average) and f 1=.963 (macro average). As a result of keyword matching and restraint concept extraction, the system obtained high precision also on unstructured or exceptionally short documents, and documents with uncommon layout. The developed terminology and the proposed information extraction system allow to extract fine-grained information from German semi-structured transthoracic echocardiography reports

  1. Reliability of quantitative echocardiography in adult sheep and goats

    Directory of Open Access Journals (Sweden)

    Hallowell Gayle D

    2012-09-01

    Full Text Available Abstract Background Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adult sheep and goats. Fifty-one adult sheep and forty adult goats were recruited. Full echocardiographic examinations were performed in the standing unsedated animal. All animals underwent echocardiography four times in a 72-hour period. Echocardiography was performed three times by one author and once by another. Images were stored and measured offline. Technique and measurement repeatability and reproducibility and any differences due to animal or day were evaluated. Reference ranges (mean ± 2 standard deviations were calculated for both species. Results Majority of the images obtained were of good to excellent quality. Image acquisition was straightforward with 5.4% of animals demonstrating a small scanning window. Reliability was excellent for majority of dimensions and time indices. There was less variation in repeatability when compared with reproducibility and differences were greater for technique than for measurements. Dimensions that were less reliable included those for right ventricular diameter and left ventricular free wall. There were many differences in cardiac dimensions between sheep and goats. Conclusions This study has demonstrated that specific reference ranges are required for these two species. Repeatability and reproducibility were excellent for the majority of cardiac dimensions and time indices suggesting that this technique is reliable and valuable for examination of clinical cases over time and for longitudinal research studies.

  2. Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Pavaci Herribert

    2007-11-01

    Full Text Available Abstract A continuous infusion of a single high dose of dobutamine has been, recently, suggested as a simple and effective protocol of stress echocardiography. The present study assesses the feasibility, safety, and tolerability of an accelerated dobutamine stress protocol performed in patients with suspected or known coronary artery disease. Two hundred sixty five consecutive patients underwent accelerated dobutamine stress echocardiography: the dobutamine was administered at a constant dose of 50 μg/kg/min for up to 10 minutes. The mean weight-adjusted cumulative dose of dobutamine used was 330 ± 105.24 μg/kg. Total duration of dobutamine infusion was 6.6 ± 2.1 min. Heart rate rose from 69.9 ± 12.1 to 123.1 ± 22.1 beats/min at peak with a concomitant change in systolic blood pressure (127.6 ± 18.1 vs. 167.6 ± 45.0 mmHg. Dobutamine administration produced a rapid increase in heart rate (9.4 ± 5.9 beats/min2. The side effects were similar to those described with the standard protocol; the most common were frequent premature ventricular complexes (21.5%, frequent premature atrial complexes (1.5% and non sustained ventricular tachycardia (1.5%; among non cardiac symptoms the most frequent were nausea (3.4%, headache (1.1% and symptomatic hypotension (1.1%. No major side effects were observed during the test. Our data demonstrate that a continous infusion of a single high dose of dobutamine is a safe and well tolerated method of performing stress echocardiography in patients with suspected or known coronary artery disease. This new protocol requires the administration of lower cumulative dobutamine dose than standard protocol and results in a significant reduction in test time.

  3. Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    Science.gov (United States)

    2011-01-01

    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data. PMID:21943283

  4. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  5. Development of left ventricular longitudinal speckle tracking echocardiography in very low birth weight infants with and without bronchopulmonary dysplasia during the neonatal period.

    Directory of Open Access Journals (Sweden)

    Christoph Czernik

    Full Text Available OBJECTIVES: In preterm infants, postnatal myocardial adaptation may be complicated by bronchopulmonary dysplasia (BPD. We aimed to describe the development of left ventricular function by serial 2D, Doppler, and speckle tracking echocardiography (2D-STE in infants with and without BPD during the neonatal period and compare these to anthropometric and conventional hemodynamic parameters. STUDY DESIGN: Prospective echocardiography on day of life (DOL 1, 7, 14, and 28 in 119 preterm infants 10% were seen for the apical segment. While anthropometric parameters show rapid development during the first 4 weeks of life, the speckle tracking parameters did not differ statistically significantly during the neonatal period. Infants with and without BPD differed significantly (p<0.001 in the development of anthropometric parameters, conventional hemodynamic parameters except for heart rate, and 2D-STE parameters: global longitudinal systolic strain rate (GLSSR and longitudinal systolic strain for the mid left wall (LSSR. The largest differences were seen at DOL 1 and 7 in GLSSR (p<0.001 and in LSSR (p<0.01. CONCLUSIONS: Reproducible 2D-STE measurements are possible in preterm infants <1500 g. Cardiac deformation reveals early (DOL 1 and 7 ventricular changes (GLSSR and LSSR in very low birth weight infants who develop BPD.

  6. [Usefullness of transesophageal echocardiography in early detection of coronary spasm].

    Science.gov (United States)

    Sagara, M; Haraguchi, M; Hamu, Y; Isowaki, S; Yoshimura, N

    1996-04-01

    Intraoperative transesophageal echocardiography (TEE) was performed on a 62-year-old man who underwent abdominal aortic replacement for abdominal aortic aneurysm under general anesthesia combined with epidural anesthesia. Coronary artery spasm occurred after unexpected massive hemorrhage, and TEE showed hypokinesis in the posterior-inferior left ventricular wall. The changes in TEE preceded the ST elevation in the ECG. Bolus infusion of isosorbide dinitrate and continuous infusion of nitroglycerin alleviated these changes. TEE enabled us to detect and evaluate coronary spasm before the appearance of ST changes in ECG.

  7. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    Science.gov (United States)

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  8. Speckle tracking echocardiography in mature Irish Wolfhound dogs

    DEFF Research Database (Denmark)

    Westrup, Ulrik; McEvoy, Fintan

    2013-01-01

    Two-dimensional strain measurements obtained by speckle tracking echocardiography (STE) have been reported in both humans and dogs. Incorporation of this technique into canine clinical practice requires the availability of measurements from clinically normal dogs, ideally of the same breed, taken...... under normal clinical conditions.The aims of this prospective study were to assess if it is possible to obtain STE data during a routine echocardiographic examination in Irish Wolfhound dogs and that these data will provide reference values and an estimation of measurement error....

  9. Objective video quality measure for application to tele-echocardiography.

    Science.gov (United States)

    Moore, Peter Thomas; O'Hare, Neil; Walsh, Kevin P; Ward, Neil; Conlon, Niamh

    2008-08-01

    Real-time tele-echocardiography is widely used to remotely diagnose or exclude congenital heart defects. Cost effective technical implementation is realised using low-bandwidth transmission systems and lossy compression (videoconferencing) schemes. In our study, DICOM video sequences were converted to common multimedia formats, which were then, compressed using three lossy compression algorithms. We then applied a digital (multimedia) video quality metric (VQM) to determine objectively a value for degradation due to compression. Three levels of compression were simulated by varying system bandwidth and compared to a subjective assessment of video clip quality by three paediatric cardiologists with more than 5 years of experience.

  10. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  11. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    The authors searched all ... quasar, where the contribution of the Doppler motion is relatively small. ..... might contribute to the Doppler redshift distribution. 5. ... out accounting for the contamination of intervening absorption systems, which can.

  12. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  13. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  14. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  15. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  16. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  17. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review.

    Science.gov (United States)

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Zühlke, Liesl J; Engel, Mark E

    2018-02-10

    Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this

  18. Effect of stromal-cell-derived factor 1 on stem-cell homing and tissue regeneration in ischaemic cardiomyopathy

    Science.gov (United States)

    Askari, Arman T.; Unzek, Samuel; Popovic, Zoran B.; Goldman, Corey K.; Forudi, Farhad; Kiedrowski, Matthew; Rovner, Aleksandr; Ellis, Stephen G.; Thomas, James D.; DiCorleto, Paul E.; hide

    2003-01-01

    BACKGROUND: Myocardial regeneration via stem-cell mobilisation at the time of myocardial infarction is known to occur, although the mechanism for stem-cell homing to infarcted tissue subsequently and whether this approach can be used for treatment of ischaemic cardiomyopathy are unknown. We investigated these issues in a Lewis rat model (ligation of the left anterior descending artery) of ischaemic cardiomyopathy. METHODS: We studied the effects of stem-cell mobilisation by use of granulocyte colony-stimulating factor (filgrastim) with or without transplantation of syngeneic cells. Shortening fraction and myocardial strain by tissue doppler imaging were quantified by echocardiography. FINDINGS: Stem-cell mobilisation with filgrastim alone did not lead to engraftment of bone-marrow-derived cells. Stromal-cell-derived factor 1 (SDF-1), required for stem-cell homing to bone marrow, was upregulated immediately after myocardial infarction and downregulated within 7 days. 8 weeks after myocardial infarction, transplantation into the peri-infarct zone of syngeneic cardiac fibroblasts stably transfected to express SDF-1 induced homing of CD117-positive stem cells to injured myocardium after filgrastim administration (control vs SDF-1-expressing cardiac fibroblasts mean 7.2 [SD 3.4] vs 33.2 [6.0] cells/mm2, n=4 per group, pcell homing to injured myocardium and suggest a strategy for directed stem-cell engraftment into injured tissues. Our findings also indicate that therapeutic strategies focused on stem-cell mobilisation for regeneration of myocardial tissue must be initiated within days of myocardial infarction unless signalling for stem-cell homing is re-established.

  19. The importance of echocardiography in transcatheter aortic valve implantation.

    Science.gov (United States)

    Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin

    2014-01-01

    Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.

  20. Clinical assessment of transthoracic echocardiography skills: a generalizability study

    DEFF Research Database (Denmark)

    Nielsen, Dorte Guldbrand; O'Neill, Lotte; Jensen, Signe

    2015-01-01

    Context: Transthoracic echocardiography (TTE) is a widely used cardiac imaging technique that all cardiologists should be able to perform competently. Traditionally, TTE competence has been assessed by unstructured observation or in test situations separated from daily clinical practice. An objec......Context: Transthoracic echocardiography (TTE) is a widely used cardiac imaging technique that all cardiologists should be able to perform competently. Traditionally, TTE competence has been assessed by unstructured observation or in test situations separated from daily clinical practice....... An objective assessment instrument for TTE technical proficiency including a global rating score and a checklist score has previously been shown reliability and validity in a standardised setting. Objectives: As clinical test situations typically have several sources of error giving rise to variance in scores......, a more thorough examination of the generalizability of the test scores is needed. Methods Nine physicians performed a TTE scan on the same three patients. Then, two raters rated all 27 TTE scans using the TTE technical assessment in a fully crossed generalizability study. Estimated variance components...

  1. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  2. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  3. Doppler Sonographic Evaluation of Venogenic Extremity Swellings ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... potentially lead to many complications including life-threatening pulmonary arterial thrombosis. Screening and confirmation ... and exclusion of acute lower extremity DVT. Duplex ultrasound is considered as the ... this study evaluates the role of Doppler sonography in the clinical management of suspected.

  4. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  5. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  6. Fifty Years of HF Doppler Observations

    Directory of Open Access Journals (Sweden)

    T Ogawa

    2009-04-01

    Full Text Available High frequency Doppler observations of the ionosphere began in August of 1957 in Kyoto. The number of the observation points worldwide were about 40 in 1980 and are about 20 at present. By this method the movement of the ionosphere reflection height and electron density below the height can be observed. Such variations are occurred by a wide variety of sources.

  7. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  8. Aerosol distribution measurements by laser - Doppler - spectroscopy

    International Nuclear Information System (INIS)

    Baldassari, J.

    1977-01-01

    Laser-Doppler-Spectroscopy is used to study particle size distribution, especially sodium aerosols, in the presence of uncondensable gases. Theoretical basis are given, and an experimental technique is described. First theoretical results show reasonably good agreement with experimental data available; this method seems to be a promising one. (author)

  9. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  10. Measurement of ciliary beat frequency using Doppler optical coherence tomography.

    Science.gov (United States)

    Lemieux, Bryan T; Chen, Jason J; Jing, Joseph; Chen, Zhongping; Wong, Brian J F

    2015-11-01

    Measuring ciliary beat frequency (CBF) is a technical challenge and difficult to perform in vivo. Doppler optical coherence tomography (D-OCT) is a mesoscopic noncontact imaging modality that provides high-resolution tomographic images and detects micromotion simultaneously in living tissues. In this work we used D-OCT to measure CBF in ex vivo tissue as the first step toward translating this technology to clinical use. Fresh ex vivo samples of rabbit tracheal mucosa were imaged using both D-OCT and phase-contrast microscopy (n = 5). The D-OCT system was designed and built to specification in our lab (1310-nm swept source vertical-cavity surface-emitting laser [VCSEL], 6-μm axial resolution). The samples were placed in culture and incubated at 37°C. A fast Fourier transform was performed on the D-OCT signal recorded on the surface of the samples to gauge CBF. High-speed digital video of the epithelium recorded via phase-contrast microscopy was analyzed to confirm the CBF measurements. The D-OCT system detected Doppler signal at the epithelial layer of ex vivo rabbit tracheal samples suggestive of ciliary motion. CBF was measured at 9.36 ± 1.22 Hz using D-OCT and 9.08 ± 0.48 Hz using phase-contrast microscopy. No significant differences were found between the 2 methods (p > 0.05). D-OCT allows for the quantitative measurement of CBF without the need to resolve individual cilia. Furthermore, D-OCT technology can be incorporated into endoscopic platforms that allow clinicians to readily measure CBF in the office and provide a direct measurement of mucosal health. © 2015 ARS-AAOA, LLC.

  11. Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Minardi Giovanni

    2006-09-01

    Full Text Available Abstract Background The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm in relatively aged patients at mean 24 months follow-up. Methods and results The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years. All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min. The following parameters were evaluated at rest and/or under DSE: heart rate (HR, ejection fraction (EF, cardiac output (CO, peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG, effective orifice area (EOA, indexed EOA (EOAi, left ventricular mass (LVM, indexed LVM (LVMi, Velocity Time Integral at left ventricular outflow tract (VTI LVOT and transvalvular (Aortic VTI, Doppler velocity index (DVI. At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm2 and 0.76 ± 0.2 cm2/m2; DVI was normal (0.50 ± 0.1. At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m2 to 191 ± 23.8g and 114.5 ± 10.6g/m2, respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg, MnPG (up to 43.2 ± 12.7mmHg. EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm2, 0.75 ± 0.3cm2/m2 and 0.48 ± 0.1 respectively. Two patients developed significant intraventricular gradients. Conclusion These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic

  12. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  13. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  14. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  15. Strain Echocardiography Improves Risk Prediction of Ventricular Arrhythmias After Myocardial Infarction

    DEFF Research Database (Denmark)

    Haugaa, Kristina H; Grenne, Bjørnar L; Eek, Christian H

    2013-01-01

    The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI).......The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI)....

  16. Saline Contrast Echocardiography in the Era of Multimodality Imaging--Importance of "Bubbling It Right".

    Science.gov (United States)

    Gupta, Saurabh K; Shetkar, Sudhir S; Ramakrishnan, Sivasubramanian; Kothari, Shyam S

    2015-11-01

    Saline contrast echocardiography is an established imaging modality. Logical interpretation of a carefully performed study is vital to realize its diagnostic potential. In this review, we discuss utility of saline contrast echocardiography in evaluation of various pathologies within and outside the heart other than a patent foramen ovale. © 2015, Wiley Periodicals, Inc.

  17. Advanced echocardiography and clinical surrogates to risk stratify and manage patients with structural heart disease

    NARCIS (Netherlands)

    Debonnaire, Philippe Jean Marc Rita

    2016-01-01

    Part I focuses on the potential role of 3-dimensional echocardiography. At first a clinical risk score model for prediction of outcome in patients undergoing TAVI is presented (Chapter 2). Second the role of 3D-echocardiography is explored in depth in patients with mitral valve disease. Different

  18. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  19. Peculiarities of cardiac hemodynamics and functional state of left ventricular myocardium in teenagers with connective heart tissue dysplasia

    Directory of Open Access Journals (Sweden)

    Makhmudova F.M.

    2011-03-01

    Full Text Available The aim of investigation is to study heart hemodynamics in teenagers with connective tissue dysplasia of heart (CTDH. 35 patients ages 12 to 15 years with CTDH have been observed: Group I (n=14 are the patients with mitral valve prolapse (MVP without mitral regurgitation (MR and myxomatous degeneration(MD or isolated minor heart abnormalities (MHA, Group II (n=11are patients with MVP and MR in combination with 1 or2 MHA, and Group III (n=10 are patients with MVP and mixoid degeneration (MD in combination with 2 or more MHA. The control group consisted of 15 patients of the same age without MHA. All the children passed Doppler and echocardiography. According to the results significant changes of cardiohemodynamic indices in patients of Group I were not observed. The changes of size and volume indices of the left ventricle (LV, increase in wall thickness and diastolic dysfunction of the LV were observed in Group II. The significant changes of systolic function of left ventricular myocardium were observed in Group III. The study comes to the conclusion that teenagers with CTDH have definite changes of heart hemodynamics and functional state of left ventricular myocardium. These changes depend on mitral regurgitation, myxomatous degeneration and MHA combination

  20. The Pathophysiology of Decompression Sickness and the Effects of Doppler Detectable Bubbles.

    Science.gov (United States)

    1980-12-18

    workers (Harvey, 1951a and 1951b) and Blinks, Twitty and Whiteker (1951) show that muscular activity was a 23 ~I. predisposing factor to the formation of...Hills, 1966), the mechanism of action is somewhat specific (neural distension ); but for those theories utilizing circulation and/or intravascular...highly perfused non- muscular tissue, such as kidney, forms a gas phase following decompression, Doppler perivascular cuff probes were surgically placed on

  1. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges

    OpenAIRE

    Abay, T. Y.; Kyriacou, P. A.

    2016-01-01

    © 2016 Institute of Physics and Engineering in Medicine. Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of...

  2. Factors associated with diagnostic discrepancy for left ventricular hypertrophy between electrocardiography and echocardiography

    DEFF Research Database (Denmark)

    Sandager Petersen, Søren; Reinholdt Pedersen, Line; Pareek, Manan

    2017-01-01

    (absolute value/cut-off value for LVH) were used as outcome variables in order to identify explanatory variables associated with diagnostic discrepancies between ECG and echocardiography. RESULTS: Of the 1382 subjects included, 77% did not display any signs of LVH, 6% had LVH defined by ECG only, 13% had...... LVH defined by echocardiography only, and 5% had LVH on both ECG and echocardiography. Older subjects and those with higher blood pressure and RWT were more likely to have a relatively greater LVMI on echocardiography than that predicted on ECG (odds ratio: 1.65 per 10 years (95% confidence interval...... and odds ratio: 1.41 (95% CI: 1.06-1.87), p = .02), but FPG did not independently influence discrepancy between ECG and echocardiography. CONCLUSION: Age, blood pressure, female sex, greater RWT and use of antihypertensive medication were associated with a greater risk of non-consistency between LVH...

  3. The diagnostic ability of echocardiography for infective endocarditis and its associated complications.

    Science.gov (United States)

    Vilacosta, Isidre; Olmos, Carmen; de Agustín, Alberto; López, Javier; Islas, Fabián; Sarriá, Cristina; Ferrera, Carlos; Ortiz-Bautista, Carlos; Sánchez-Enrique, Cristina; Vivas, David; San Román, Alberto

    2015-11-01

    Echocardiography, transthoracic and transoesophageal, plays a key role in the diagnosis and prognosis assessment of patients with infective endocarditis. It constitutes a major Duke criterion and is pivotal in treatment guiding. Seven echocardiographic findings are major criteria in the diagnosis of infective endocarditis (IE) (vegetation, abscess, pseudoaneurysm, fistulae, new dehiscence of a prosthetic valve, perforation and valve aneurysm). Echocardiography must be performed as soon as endocarditis is suspected. Transoesophageal echocardiography should be done in most cases of left-sided endocarditis to better define the anatomic lesions and to rule out local complications. Transoesophageal echocardiography is not necessary in isolated right-sided native valve IE with good quality transthoracic examination and unequivocal echocardiographic findings. Echocardiography is a very useful tool to assess the prognosis of patients with IE at any time during the course of the disease. Echocardiographic predictors of poor outcome include presence of periannular complications, prosthetic dysfunction, low left ventricular ejection fraction, pulmonary hypertension and very large vegetations.

  4. Evolution of echocardiography in subclinical detection of cancer therapy-related cardiac dysfunction.

    Science.gov (United States)

    Moudgil, Rohit; Hassan, Saamir; Palaskas, Nicolas; Lopez-Mattei, Juan; Banchs, Jose; Yusuf, Syed Wamique

    2018-05-11

    Cancer therapies have resulted in increased survivorship in oncological patients. However, the benefits have been marred by the development of premature cardiovascular disease. The current definition outlines measurement of ejection fraction as a mean to diagnose cancer therapeutic-related cardiac dysfunction (CTRCD); however, up to 58% of the patients do not regain their cardiac function after the CTRCD diagnosis, despite therapeutic interventions. Therefore, there has been a growing interest in the markers for early myocardial changes (ie, changes with normal left ventricular ejection fraction [LVEF]) that may predict the development of subsequent left ventricular ejection fraction reduction or progression to heart failure. This review will highlight the use of diastolic parameters, tissue Doppler imaging (TDI), and speckle tracking echocardiogram (STE) as emerging technologies which can potentially detect cardiac dysfunction thereby stratifying patients for cardioprotective therapies. The goal of this manuscript was to highlight the concepts and discuss the current controversies surrounding these echocardiographic imaging modalities. © 2018 Wiley Periodicals, Inc.

  5. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  6. Doppler-Defined Pulmonary Hypertension in Sickle Cell Anemia in Kurdistan, Iraq.

    Science.gov (United States)

    Al-Allawi, Nasir; Mohammad, Ameen M; Jamal, Shakir

    2016-01-01

    To determine the frequency, clinical and laboratory associations of pulmonary hypertension in Iraqi Kurds with sickle cell anemia, a total of ninety four such patients attending a major hemoglobinopathy center in Iraqi Kurdistan were enrolled. All patients were re-evaluated clinically and had their blood counts, HbF, serum ferritin, LDH, renal and liver function assessed. Transthoracic Doppler echocardiography with measurement of tricuspid valve regurgitant jet velocity (TRV) was performed. A TRV in excess of 2.8 m/s was considered for the purposes of this study as indicative of pulmonary hypertension (PH). The prevalence of TRV in excess of 2.8m/s was 10.6%. By univariate analysis: significantly higher reticulocyte count, more frequent blood transfusions and pain episodes were encountered in the PH group as compared to the non-PH group (p = 0.001, 0.045 and 0.02 respectively). Moreover, PH patients had significantly higher mean right atrial area, left atrial size, E wave/A wave ratio and ejection fraction by echocardiography (p = 0.027, 0.037, <0.001 and 0.008 respectively). Except for reticulocyte count none of the other parameters remained significant by multivariate analysis (p = 0.024). In conclusion the current study revealed that pulmonary hypertension is rather frequent among Iraqi Kurds with sickle cell anemia, and identified reticulocyte count as an independently associated parameter with PH in this population. Future prospective studies including right heart catheterization and appropriate medical intervention are warranted.

  7. Basic heart examination: feasibility study of first-trimester systematic simplified fetal echocardiography.

    Science.gov (United States)

    Quarello, E; Lafouge, A; Fries, N; Salomon, L J

    2017-02-01

    First-trimester fetal cardiac screening examinations in low-risk populations should not have to meet the specifications required for high-risk populations. Our aim was to evaluate a simplified fetal echocardiographic ('basic heart') examination for early detection of severe congenital heart defects in a low-risk population. This was a first-trimester national 'flash study', performed over a 2-week period. Each observer was requested to perform simplified echocardiography without modifying the time and methods deemed necessary for the routine first-trimester ultrasound examination, in fetuses with crown-rump length between 45 and 84 mm. This basic heart assessment used targeted cross-sections of the four-chamber view (4CV) and of the three vessels and trachea (3VT) view, using color and/or directional power Doppler. All examinations were then reviewed offline and scored for quality by a qualified expert. Sixty observers performed a total of 597 first-trimester ultrasound examinations, each performing an average of 10 (range, 1-26) procedures. Examinations were conducted transabdominally (79%; 472/597), transvaginally (3%; 17/597) or both (18%; 108/597). In 8% (45/597) of cases, the fetal back was anterior, in 18% (108/597) it was on the left side, in 63% (377/597) it was posterior and in 11% (67/597) it was on the right side. It became clear during scoring by the expert that, unlike the Herman quality score for nuchal translucency measurement, it was difficult to assess the quality of these images without taking into account normality of the heart itself. Analysis of scores showed that the 4CV was obtained successfully and was deemed normal in 86% (512/597) of the patients, in 7% (41/597) it was deemed technically infeasible and in 7% (44/597) it was deemed feasible but atypical, which may have been due to the presence of an abnormality or to poor quality of the image. The 3VT view was obtained successfully and was normal in 79% (472/597) of the patients, in 13

  8. Increased left ventricular mass index is present in patients with type 2 diabetes without ischemic heart disease

    DEFF Research Database (Denmark)

    Seferovic, Jelena P; Tesic, Milorad; Seferovic, Petar M

    2018-01-01

    , stress echocardiography, transthoracic 2D Doppler and tissue Doppler echocardiography were performed. Multivariable logistic regression was used to determine the independent association with T2DM. Linear regression models and Pearson's correlation were used to assess the correlations between LVMI.......029). A positive correlation of LVMI was found with fasting glucose (p 

  9. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  10. Bioeffects of albumin-encapsulated microbubbles and real-time myocardial contrast echocardiography in an experimental canine model

    Directory of Open Access Journals (Sweden)

    P.M.M. Dourado

    2006-06-01

    Full Text Available Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS. In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.

  11. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  12. [Peculiarities of the transesophageal echocardiography in octogenarian patients].

    Science.gov (United States)

    Canale, Jesús M; Cardoza-Encinas, Rubén; Canale-Segovia, Andrés

    The growing trend in the absolute and relative number of elderly in the population scheme, the increasing prevalence of heart disease as people get older and the impressive technological development of ultrasound devices have all together recently contributed to promote an increasing number of transesophageal echocardiograms in older patients, however, the already published information about the distinguishing features of this diagnostic methodology in elderly patients is still scarce and seems to be insufficient. This review focuses on the already published methodological and diagnostic features related to the transesophageal echocardiography in the octogenarian -or even older patient- in order to show them in an orderly and systematic manner to provide elements that induce useful clinical criteria for the physician who attends patients in this age group in whom this diagnostic modality is now increasingly requested. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  13. Two-years therapy with bosentan of pulmonary arterial hypertension related to connective tissue diseases

    Directory of Open Access Journals (Sweden)

    M. Rizzo

    2011-09-01

    Full Text Available Objective: Pulmonary arterial hypertension (PAH is a rare but severe complication of connective tissue diseases (CTD, with a negative impact on patients survival. Bosentan, a receptor antagonist of endothelin, has been proved effective for the treatment of PAH. The aim of this study was to evaluate the effects and the safety of bosentan administered for 2 years in a group of patients with PAH related to CTD. Methods: Twelve patients with PAH related to systemic sclerosis (8 cases, SLE (2 cases, mixed connective tissue disease (1 case and polymyositis (1 case attending the Rheumatology Unit of Padova University were treated with bosentan for two years. Distance walked in 6 minutes, right ventricular systolic pressure and mean pulmonary artery pressure estimated by doppler echocardiography were evaluated at baseline and after 6, 12, 18 and 24 months of treatment. Safety was assessed by laboratory tests performed every two months. Results: During bosentan treatment, a significant decrease of right ventricular systolic pressure was observed after 6, 12, 18 and 24 months in comparison to baseline, whereas pulmonary artery mean pressure remained unchanged. Distance walked in 6 minutes slightly increased after 6 and 12 months, but significantly decreased after 18 and 24 months, mostly because complications of CTD which compromised the ability to walk arose in 4 patients. Adverse events related to bosentan were observed in 2 cases. Conclusions: Bosentan has been demonstrated effective in reducing pulmonary arterial pressure in a two-year period of treatment. Exercise capacity improved only in the first year of therapy and worsened thereafter, suggesting the opportunity of a combination therapy for a long-term treatment of PAH related to CTD.

  14. ECHOCARDIOGRAPHY BASED STUDY OF THE PREVALENCE AND PATTERN OF CONGENITAL HEART DISEASE (CHD IN 5-15 YEARS OLD SCHOOL GOING CHILDREN OF MANIPUR, A NORTH-EAST HILLY INDIAN STATE

    Directory of Open Access Journals (Sweden)

    Rajendra Singh Thangjam

    2017-12-01

    Full Text Available BACKGROUND CHD is the leading cause of morbidity and mortality in the developed world, while reports from India looking into the burden of the disease have been variable depending on the age group of subjects studied and the methodology involved. We were interested to find the prevalence and pattern of the disease in this north eastern Indian state of Manipur, which has a unique geographical and racial composition. MATERIALS AND METHODS This is a community based, prospective, cross sectional study where each and every child aged 5-15 years from randomly selected schools of Manipur were examined by 2D colour Doppler Echocardiography and physically as well, where the examiners were blinded, and the findings were noted independent of each other. The anthropometric parameters, clinical details and echocardiography findings were all recorded. RESULTS Of the 3600 children examined, 47 cases of CHD were detected, giving echocardiographic prevalence of 13 per 1000 where BAV (44% was found as the commonest lesion followed by VSD (17% and ASD (14%. Clinically detectable lesion was found in 21 subjects (VSD -8, ASD-7, PS-3, PDA -1, AVSD-1, BAV-1 with AR. Of the clinically detectable CHD, VSD was the commonest followed by ASD. In the subclinical CHD category, 20 cases of BAV, 4 cases of mild MVP without MR, 1 case of apical LV discompacta, 1 case of IASA were detected. CONCLUSION The echocardiography prevalence of congenital heart disease in school going children of Manipur is 13/1000. This highest ever reported prevalence of CHD in children is most probably related to the use of the highly sensitive investigative tool of Echocardiography in each subject of our study resulting in detection of clinically silent lesions.

  15. Handheld echocardiography during hospitalization for acute myocardial infarction.

    Science.gov (United States)

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  16. On-Orbit Prospective Echocardiography on International Space Station Crew

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David S.; Garcia, Kathleen M.; Melton, Shannon L.; Feiveson, Alan; Dulchavsky, Scott A.

    2010-01-01

    Introduction A prospective trial of echocardiography was conducted on of six crewmembers onboard the International Space Station. The main objective was to determine the efficacy of remotely guided tele-echocardiography, including just-in-time e-training methods and determine what "space normal" echocardiographic data is. Methods Each crewmember operator (n=6) had 2-hour preflight training. Baseline echocardiographic data were collected 55 to 167days preflight. Similar equipment was used in each 60-minute in-flight session (mean microgravity exposure - 114 days (34 -- 190)). On Orbit ultrasound operators used an e-learning system within 24h of these sessions. Expert assistance was provided using ultrasound video downlink and two-way voice. Testing was repeated 5 to 16 days after landing. Separate ANOVA was used on each echocardiographic variable (n=33). Within each ANOVA, three tests were made: a) effect of mission phase (preflight, in-flight, post flight); b) effect of echo technician (two technicians independently analyzed the data); c) interaction between mission phase and technician. Results Nine rejections of the null hypothesis (mission phase or technician or both had no effect) were discovered and considered for follow up. Of these, six rejections were for significant technician effects, not as a result of space flight. Three rejections of the null hypothesis (Aortic Valve time velocity integral, Mitral E wave Velocity and heart rate) were attributable to space flight, however determined not to be clinically significant. No rejections were due to the interaction between technician and space flight. Conclusion No consistent clinically significant effects of long-duration space flight were seen in echocardiographic variables of the given group of subjects.

  17. Handheld echocardiography versus auscultation for detection of rheumatic heart disease.

    Science.gov (United States)

    Godown, Justin; Lu, Jimmy C; Beaton, Andrea; Sable, Craig; Mirembe, Grace; Sanya, Richard; Aliku, Twalib; Yu, Sunkyung; Lwabi, Peter; Webb, Catherine L; Ensing, Gregory J

    2015-04-01

    Rheumatic heart disease (RHD) remains a major public health concern in developing countries, and routine screening has the potential to improve outcomes. Standard portable echocardiography (STAND) is far more sensitive than auscultation for the detection of RHD but remains cost-prohibitive in resource-limited settings. Handheld echocardiography (HAND) is a lower-cost alternative. The purpose of this study was to assess the incremental value of HAND over auscultation to identify RHD. RHD screening was completed for schoolchildren in Gulu, Uganda, by using STAND performed by experienced echocardiographers. Any child with mitral or aortic regurgitation or stenosis plus a randomly selected group of children with normal STAND findings underwent HAND and auscultation. STAND and HAND studies were interpreted by 6 experienced cardiologists using the 2012 World Heart Federation criteria. Sensitivity and specificity of HAND and auscultation for the detection of RHD and pathologic mitral or aortic regurgitation were calculated by using STAND as the gold standard. Of 4773 children who underwent screening with STAND, a subgroup of 1317 children underwent HAND and auscultation. Auscultation had uniformly poor sensitivity for the detection of RHD or valve disease. Sensitivity was significantly improved by using HAND compared with auscultation for the detection of definite RHD (97.8% vs 22.2%), borderline or definite RHD (78.4% vs 16.4%), and pathologic aortic insufficiency (81.8% vs 13.6%). Auscultation alone is a poor screening test for RHD. HAND significantly improves detection of RHD and may be a cost-effective screening strategy for RHD in resource-limited settings. Copyright © 2015 by the American Academy of Pediatrics.

  18. Successful percutaneous coronary intervention significantly improves coronary sinus blood flow as assessed by transthoracic echocardiography.

    Science.gov (United States)

    Lyubarova, Radmila; Boden, William E; Fein, Steven A; Schulman-Marcus, Joshua; Torosoff, Mikhail

    2018-06-01

    Transthoracic echocardiography (TTE) has been used to assess coronary sinus blood flow (CSBF), which reflects total coronary arterial blood flow. Successful angioplasty is expected to improve coronary arterial blood flow. Changes in CSBF after percutaneous coronary intervention (PCI), as assessed by TTE, have not been systematically evaluated. TTE can be utilized to reflect increased CSBF after a successful, clinically indicated PCI. The study cohort included 31 patients (18 females, 62 ± 11 years old) referred for diagnostic cardiac catheterization for suspected coronary artery disease and possible PCI, when clinically indicated. All performed PCIs were successful, with good angiographic outcome. CSBF per cardiac cycle (mL/beat) was measured using transthoracic two-dimensional and Doppler flow imaging as the product of coronary sinus (CS) area and CS flow time-velocity integral. CSBF per minute (mL/min) was calculated as the product of heart rate and CSBF per cardiac cycle. In each patient, CSBF was assessed prospectively, before and after cardiac catheterization with and without clinically indicated PCI. Within- and between-group differences in CSBF before and after PCI were assessed using repeated measures analysis of variance. Technically adequate CSBF measurements were obtained in 24 patients (77%). In patients who did not undergo PCI, there was no significant change in CSBF (278.1 ± 344.1 versus 342.7 ± 248.5, p = 0.36). By contrast, among patients who underwent PCI, CSBF increased significantly (254.3 ± 194.7 versus 618.3 ± 358.5 mL/min, p < 0.01, p-interaction = 0.03). Other hemodynamic and echocardiographic parameters did not change significantly before and after cardiac catheterization in either treatment group. Transthoracic echocardiographic assessment can be employed to document CSBF changes after angioplasty. Future studies are needed to explore the clinical utility of this noninvasive metric.

  19. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  20. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)