WorldWideScience

Sample records for echocardiography three-dimensional

  1. Three-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Thomas [University Hospital Essen (Germany). West German Heart Center; Franke, Andreas [Klinikum Region Hannover - Klinikum Siloah, Hannover (Germany). Dept. of Cardiology, Angiology and Intensive Care Medicine; Monaghan, Mark J. (eds.) [King' s College Hospital, London (United Kingdom)

    2011-07-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  2. Advanced Three-Dimensional Echocardiography

    NARCIS (Netherlands)

    B. Ren (Ben)

    2014-01-01

    markdownabstract__Abstract__ During the development of echocardiography, 3D echocardiography imaging represents a major innovation in cardiovascular ultrasound (Figure 1). Advancements in computer and transducer technologies permit real-time 3D acquisition and presentation of cardiac

  3. Three-dimensional echocardiography in valve disease.

    Science.gov (United States)

    Colombo, Chiara; Tamborini, Gloria; Pepi, Mauro; Alimento, Marina; Fiorentini, Cesare

    2007-01-01

    This review covers the role of three-dimensional (3D) echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic) and quantitative advantages of this technique.

  4. Artifacts in three-dimensional transesophageal echocardiography.

    Science.gov (United States)

    Faletra, Francesco Fulvio; Ramamurthi, Alamelu; Dequarti, Maria Cristina; Leo, Laura Anna; Moccetti, Tiziano; Pandian, Natesa

    2014-05-01

    Three-dimensional (3D) transesophageal echocardiography (TEE) is subject to the same types of artifacts encountered on two-dimensional TEE. However, when displayed in a 3D format, some of the artifacts appear more "realistic," whereas others are unique to image acquisition and postprocessing. Three-dimensional TEE is increasingly used in the setting of percutaneous catheter-based interventions and ablation procedures, and 3D artifacts caused by the metallic components of catheters and devices are particularly frequent. Knowledge of these artifacts is of paramount relevance to avoid misinterpretation of 3D images. Although artifacts and pitfalls on two-dimensional echocardiography are well described and classified, a systematic description of artifacts in 3D transesophageal echocardiographic images and how they affect 3D imaging is still absent. The aim of this review is to describe the most relevant artifacts on 3D TEE, with particular emphasis on those occurring during percutaneous interventions for structural heart disease and ablation procedures.

  5. Three-dimensional Echocardiography in Valvular Heart Disease.

    Science.gov (United States)

    Kurklinsky, Andrew; Mankad, Sunil

    2012-01-01

    Recent technologic advances in 3-dimensional (3D) echocardiography, using parallel processing to scan a pyramidal volume, have allowed for a superior ability to describe valvular anatomy using both transthoracic and transesophageal echocardiography. Although still in evolution and at an early phase of adaptation with respect to its clinical application, 3D echocardiography has emerged as an important clinical tool in the assessment of valvular heart disease. Three-dimensional echocardiography provides unique perspectives of valvular structures by presenting "en face" views of valvular structures, allowing for a better understanding of the topographical aspects of pathology, and a refined definition of the spatial relationships of intracardiac structures. Three-dimensional echocardiography makes available indices not described by 2D echocardiography and has been demonstrated to be superior to 2D echocardiography in a variety of valvular disease scenarios. The information gained from 3D echocardiography has especially made an impact in guiding clinical decisions in the evaluation of mitral valve (MV) disease. The decision of early surgery in degenerative MV disease is based on the suitability of repair, and the suitability of repair is generally based on echocardiography. The superior understanding of MV anatomy afforded by 3D echocardiography has been shown to be quite valuable in this setting. This review will describe the contemporary use of 3D echocardiography in the assessment of valvular heart disease, including MV, aortic, tricuspid, and prosthetic valve abnormalities. This article illustrates how 3D echocardiography can complement current echocardiography techniques in the management of valvular heart disease.

  6. Automated analysis of three-dimensional stress echocardiography

    NARCIS (Netherlands)

    K.Y.E. Leung (Esther); M. van Stralen (Marijn); M.G. Danilouchkine (Mikhail); G. van Burken (Gerard); M.L. Geleijnse (Marcel); J.H.C. Reiber (Johan); N. de Jong (Nico); A.F.W. van der Steen (Ton); J.G. Bosch (Johan)

    2011-01-01

    textabstractReal-time three-dimensional (3D) ultrasound imaging has been proposed as an alternative for two-dimensional stress echocardiography for assessing myocardial dysfunction and underlying coronary artery disease. Analysis of 3D stress echocardiography is no simple task and requires considera

  7. Live three-dimensional transesophageal echocardiography in mitral valve surgery

    Institute of Scientific and Technical Information of China (English)

    MA Ning; LI Zhi-an; MENG Xu; YANG Ya

    2008-01-01

    Background Live three-dimensional transesophageal echocardiography (live-3D-TEE) is a new technique, but its clinical value is unclear at present. This study aimed to investigate the feasibility, imaging quality and accuracy of live-3D-TEE for assessing mitral valve morphology to determine if live-3D-TEE has important value in mitral valve surgery.Methods Twenty-four patients with mitral valve disease (mean age (47.1 rdiography (2D-TEE) before and after mitral valve surgery. Sensitivity, specificity, and total consistency rates of live-3D-TEE for diagnosing ruptured chordae were calculated and compared to surgeon's findings. We also compared the diagnostic accuracy of mitral valve disease between live-3D-TEE and 2D-TEE.Results Live-3D-TEE allowed visualization of the anatomic structure of the heart online and clearly identified the valvular apparatus and their defects. Sensitivity and specificity for the detection of ruptured chordae by live-3D-TEE were 87.5% and 100% respectively, and the total consistency rate was 95.8%. Additional defects not diagnosted by 2D-TEE were found in three cases (12.5%) preoperatively by live-3D-TEE. Live-3D-TEE could evaluate the function of prosthetic or native valves immediately after operation. One case was re-repaired (4.2%) using guidance by live-3D-TEE. Conclusion Live-3D-TEE enabled evaluation of mitral valve function and provided adequate valuable information before and after mitral valve surgery. We conclude that live-3D-TEE can play an important role in mitral valve surgery.

  8. Usefulness of three-dimensional echocardiography in the assessment of valvular involvement in Loeffler endocarditis.

    Science.gov (United States)

    Hernandez, Carlos M; Arisha, Mohammed J; Ahmad, Amier; Oates, Ethan; Nanda, Navin C; Nanda, Anil; Wasan, Anita; Caleti, Beda E; Bernal, Cinthia L P; Gallardo, Sergio M

    2017-07-01

    Loeffler endocarditis is a complication of hypereosinophilic syndrome resulting from eosinophilic infiltration of heart tissue. We report a case of Loeffler endocarditis in which three-dimensional transthoracic and transesophageal echocardiography provided additional information to what was found by two-dimensional transthoracic echocardiography alone. Our case illustrates the usefulness of combined two- and three-dimensional echocardiography in the assessment of Loeffler endocarditis. In addition, a summary of the features of hypereosinophilic syndrome and Loeffler endocarditis is provided in tabular form. © 2017, Wiley Periodicals, Inc.

  9. Making three-dimensional echocardiography more tangible: a workflow for three-dimensional printing with echocardiographic data

    Directory of Open Access Journals (Sweden)

    Azad Mashari MD

    2016-12-01

    Full Text Available Three-dimensional (3D printing is a rapidly evolving technology with several potential applications in the diagnosis and management of cardiac disease. Recently, 3D printing (i.e. rapid prototyping derived from 3D transesophageal echocardiography (TEE has become possible. Due to the multiple steps involved and the specific equipment required for each step, it might be difficult to start implementing echocardiography-derived 3D printing in a clinical setting. In this review, we provide an overview of this process, including its logistics and organization of tools and materials, 3D TEE image acquisition strategies, data export, format conversion, segmentation, and printing. Generation of patient-specific models of cardiac anatomy from echocardiographic data is a feasible, practical application of 3D printing technology.

  10. Three-dimensional transesophageal echocardiography: Principles and clinical applications

    Directory of Open Access Journals (Sweden)

    Annette Vegas

    2016-01-01

    Full Text Available A basic understanding of evolving 3D technology enables the echocardiographer to master the new skills necessary to acquire, manipulate, and interpret 3D datasets. Single button activation of specific 3D imaging modes for both TEE and transthoracic echocardiography (TTE matrix array probes include (a live, (b zoom, (c full volume (FV, and (d color Doppler FV. Evaluation of regional LV wall motion by RT 3D TEE is based on a change in LV chamber subvolume over time from altered segmental myocardial contractility. Unlike standard 2D TEE, there is no direct measurement of myocardial thickening or displacement of individual segments.

  11. Three-Dimensional Echocardiography of the Aortic Valve: Feasibility, Clinical Potential, and Limitations.

    Science.gov (United States)

    Kasprzak, Jaroslaw D.; Salustri, Alessandro; Roelandt, Jos R.T.C.; Ten Cate, Folkert J.

    1998-02-01

    OBJECTIVES: The purpose of our study was to assess the feasibility and potential clinical utility of three-dimensional echocardiography for evaluation of the aortic valve. BACKGROUND: The value of three-dimensional echocardiographic assessment of the aortic valve has not been established yet. METHODS: The study group comprised 32 patients (11 women, 21 men), mean age 56.1 (range 20-82). Seven morphologically normal valves, 5 homografts, 6 mechanical prostheses, and 14 valves of abnormal morphology were evaluated. Images were acquired during a routine multiplane transesophageal echocardiographic examination (rotational scan with 2 degrees interval, respiration, and electrocardiogram [ECG] gating) and postprocessed off-line. A selection of reconstructed cutplanes (anyplane mode) and volume-rendered three-dimensional views of aortic valve anatomy were analyzed by two observers and compared with two-dimensional echocardiography findings. RESULTS: The quality of reconstructions was scored excellent when permitting unrestricted assessment of aortic valve anatomy with optimized planimetric measurements (19 patients, 59%), adequate when aortic valve was partially visualized (7 patients, 22%), or inadequate when no assessment was possible (6 patients, 19%, including 5 with prosthetic valves). Three-dimensional echocardiography provided additional information in ten (31%) patients as compared with the two-dimensional echocardiographic findings. CONCLUSIONS: It can be concluded that three-dimensional echocardiographic reconstruction of the aortic valve is feasible, with excellent or adequate quality in 81% of patients, more frequently in native than in prosthetic valves, P < 0.05. Morphologic information additional to that provided by two-dimensional echocardiography is obtained in a significant proportion of patients.

  12. Three-dimensional Echocardiography of Right Ventricular Function Correlates with Severity of Pediatric Pulmonary Hypertension.

    Science.gov (United States)

    Jone, Pei-Ni; Patel, Sonali S; Cassidy, Courtney; Ivy, David Dunbar

    2016-12-01

    Right ventricular function and biomarkers of B-type natriuretic peptide (BNP) and N-Terminal pro-BNP (NT pro-BNP) are used to determine the severity of right ventricular failure and outcomes from pulmonary hypertension. Real-time three-dimensional echocardiography (3DE) is a novel quantitative measure of the right ventricle and decreases the geometric assumptions from conventional two-dimensional echocardiography (2DE). We correlated right ventricular functional measures using 2DE and single-beat 3DE with biomarkers and hemodynamics to determine the severity of pediatric pulmonary hypertension. We retrospectively evaluated 35 patients (mean age 12.67 ± 5.78 years) with established pulmonary hypertension who had echocardiograms and biomarkers on the same day. Ten out of 35 patients had hemodynamic evaluation within 3 days. 2DE evaluation included tricuspid annular plane systolic excursion (TAPSE), right ventricular myocardial performance index from tissue Doppler imaging (RV TDI MPI), and right ventricular fractional area change (FAC). Three-dimensional echocardiography evaluation included right ventricular ejection fraction (EF), end-systolic volume, and end-diastolic volume. The quality of the 3DE was graded as good, fair, or poor. Pearson correlation coefficients were utilized to evaluate between biomarkers and echocardiographic parameters and between hemodynamics and echocardiography. Three-dimensional echocardiography and FAC correlated significantly with BNP and NT pro-BNP. TAPSE and RV TDI MPI did not correlate significantly with biomarkers. 3D right ventricular EF correlated significantly with hemodynamics. Two-dimensional echocardiography did not correlate with hemodynamics. Single-beat 3DE is a noninvasive, feasible tool in the quantification of right ventricular function and maybe more accurate than conventional 2DE in evaluating severity of pulmonary hypertension. © 2016 Wiley Periodicals, Inc.

  13. Dynamic three-dimensional reconstruction of the heart by transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Veiga Maria de Fátima

    1999-01-01

    Full Text Available OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D reconstruction. METHODS: Three-dimensional (3D image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic; mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA; arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD. Fifty five of 60 (91.6% reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

  14. Real-time three-dimensional speckle tracking echocardiography: technical aspects and clinical applications

    Directory of Open Access Journals (Sweden)

    Sorrentino R

    2016-11-01

    Full Text Available Regina Sorrentino, Roberta Esposito, Enrica Pezzullo, Maurizio Galderisi Department of Advanced Biomedical Sciences, Interdepartmental Laboratory of Cardiac Imaging, Federico II University Hospital, Naples, Italy Abstract: Three-dimensional speckle tracking echocardiography (3D STE is a novel technique for the quantification of cardiac deformation based on tracking of ultrasonic speckles in gray scale full-volume 3D images. Developments in ultrasound technologies have made 3D speckle tracking widely available. Two-dimensional echocardiography has intrinsic limitations regarding estimation of left ventricular (LV volumes, ejection fraction, and LV mechanics, due to its inherent foreshortening errors and dependency on geometric models. The development of 3D echocardiography has improved reproducibility and accuracy. Data regarding the feasibility, accuracy, and clinical applications of 3D STE are rapidly assembling. From the tracking results, 3D STE derives several parameters, including longitudinal, circumferential and radial strain, as well as a combined assessment of longitudinal and circumferential strain, termed area strain. 3D STE can also quantify LV rotational movements such as rotation, twist, and torsion. 3D STE provides a better insight on global and regional myocardial deformation. Main applications include detection of subclinical myocardial involvement in heart failure, arterial hypertension, dyssynchrony, and ischemic heart disease. Emerging areas of application include a large spectrum of heart-involving systemic conditions, such as prediction of rejection in heart transplant patients, early detection of cardiotoxicity in patients receiving chemotherapy for cancer, and deeper physiological understanding of LV contraction mechanics in different types of athletes. Aim of this review is to discuss background, technical acquisition and processing aspects as well as recognized and developing clinical applications of this emerging

  15. Three-dimensional Transesophageal Echocardiography-guided Transcathetar Closure of Ruptured Noncoronary Sinus of Valsalva Aneurysm

    Science.gov (United States)

    Kumar, G Anil; Parimala, P S; Jayaranganath, M; Jagadeesh, A M

    2017-01-01

    Sinus of Valsalva aneurysm accounts for only 1% of congenital cardiac anomalies. Sinus of Valsalva aneurysm can cause aortic insufficiency, coronary artery flow compromise, cardiac arrhythmia, or aneurysm rupture. Three-dimensional transesophageal echocardiography (3DTEE) represents an adjunctive tool to demonstrate the ruptured sinus of Valsalva with better delineation. We present an adult patient with rupture of noncoronary sinus of Valsalva aneurysm into the right atrium (RA). 3DTEE accurately delineated the site of rupture into the RA and showed the exact size and shape of the defect, which helped in the successful transcatheter closure of the defect with a duct occluder device. PMID:28074828

  16. Ventricular septal rupture imaged with real-time three-dimensional transesophageal echocardiography: diagnosis at a glance.

    Science.gov (United States)

    Squeri, Angelo; Conti, Rita; Bosi, Stefano

    2014-01-01

    Ventricular septal rupture is a rare complication of acute myocardial infarction and its diagnosis can be really challenging especially in the case of complex lesions. Echocardiography is the technique of choice for the detection of mechanical complications following myocardial infarction. The introduction of three-dimensional echocardiography offers new imaging possibilities with precise localization and easiest definition of the defect anatomy. This information is of paramount importance in the setting of a percutaneous closure procedure. We describe a case where real-time three-dimensional transesophageal echocardiography correctly defined the complex anatomy of a postmyocardial infarction septal defect with an associated pseudoaneurysm.

  17. [Congenital heart disease: Recent technical advances in three-dimensional echocardiography].

    Science.gov (United States)

    Karsenty, Clement; Hadeed, Khaled; Acar, Philippe

    2017-05-01

    The recent technical advances allow the use in practice of three-dimensional echocardiography in children especially through the new high frequency matrix probe. It is difficult or even impossible to hold breathing during children' acquisition so to avoid motion full volume artifact, one beat and live 3D modes are suitable. 3D echocardiography is more accurate than 2D to assess the size, location, and relationship with surrounding structures of atrial and ventricular septal defects and thus helps in the therapeutic decision. 3D echocardiography enables to guide precisely percutaneous procedure. The morphology of the valve leaflets, chordal support apparatus, papillary muscle and the annulus are particularly well described in 3D and allows assessment of the regurgitation before repair and after as well for the common valve of the atrioventricular septal defect or in the Ebstein anomaly. Complex heart diseases such as double outlet right ventricle are suitable to a tridimensional assessment to plan surgical strategy. 3D printing, fusion imaging in cathlab and automated volume quantification embody recent innovations of new techniques in congenital heart disease. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Automated Assessment of Right Ventricular Volumes and Function Using Three-Dimensional Transesophageal Echocardiography.

    Science.gov (United States)

    Nillesen, Maartje M; van Dijk, Arie P J; Duijnhouwer, Anthonie L; Thijssen, Johan M; de Korte, Chris L

    2016-02-01

    Assessment of right ventricular (RV) function is known to be of diagnostic value in patients with RV dysfunction. Because of its complex anatomic shape, automated determination of the RV volume is difficult and strong reliance on geometric assumptions is not desired. A method for automated RV assessment was developed using three-dimensional (3-D) echocardiography without relying on a priori knowledge of the cardiac anatomy. A 3-D adaptive filtering technique that optimizes the discrimination between blood and myocardium was applied to facilitate endocardial border detection. Filtered image data were incorporated in a segmentation model to automatically detect the endocardial RV border. End-systolic and end-diastolic RV volumes, as well as ejection fraction, were computed from the automatically segmented endocardial surfaces and compared against reference volumes manually delineated by two expert cardiologists. The results reported good performance in terms of correlation and agreement with the results from the reference volumes.

  19. Incremental Value of Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Technique in the Assessment of a Thrombus in Transit through a Patent Foramen Ovale.

    Science.gov (United States)

    Thind, Munveer; Ahmed, Mustafa I; Gok, Gulay; Joson, Marisa; Elsayed, Mahmoud; Tuck, Benjamin C; Townsley, Matthew M; Klas, Berthold; McGiffin, David C; Nanda, Navin C

    2015-05-01

    We report a case of a right atrial thrombus traversing a patent foramen ovale into the left atrium, where three-dimensional transesophageal echocardiography provided considerable incremental value over two-dimensional transesophageal echocardiography in its assessment. As well as allowing us to better spatially characterize the thrombus, three-dimensional transesophageal echocardiography provided a more quantitative assessment through estimation of total thrombus burden.

  20. The additional value of three-dimensional transesophageal echocardiography in complex aortic prosthetic heart valve endocarditis.

    Science.gov (United States)

    Tanis, Wilco; Teske, Arco J; van Herwerden, Lex A; Chamuleau, Steven; Meijboom, Folkert; Budde, Ricardo P J; Cramer, Maarten-Jan

    2015-01-01

    Two-dimensional transthoracic and transesophageal echocardiography (2DTTE and 2DTEE) may fail to detect signs of prosthetic heart valve (PHV) endocarditis due to acoustic shadowing. Three-dimensional (3D) TEE may have additional value; however, data are scarce. This study was performed to investigate the additional value of 3DTEE for the detection of aortic PHV endocarditis and the extent of the disease process. Retrospective analysis of complex aortic PHV endocarditis cases that underwent 2DTTE, 2DTEE, and 3DTEE before surgery. Echocardiograms were individually assessed by 2 cardiologists blinded for the outcome. Surgical and pathological inspection served as the reference standard for vegetations and peri-annular extensions (abscesses/mycotic aneurysms). To determine if the proximal coronary arteries were involved in the inflammatory process as well, computed tomography angiography findings were added to reference standard. Fifteen aortic PHV endocarditis cases were identified. According to the reference standard, all 15 cases had peri-annular extensions, 13 of which had a close relationship with the proximal right and/or left coronary artery. In 6 of 15 patients, a vegetation was present. Combined 2DTTE/TEE missed 1/6 vegetations and 1/15 peri-annular extensions. After addition of 3DTEE, all vegetations (6/6) and peri-annular extensions (15/15) were detected, without adding false positives. Compared to 2DTEE, in 3/15 cases, 3DTEE resulted in better delineation of the anatomical relationship of the proximal coronary arteries to the peri-annular extensions. As a result, 3DTEE had an additional value in 5/15 cases. In complex aortic, PHV endocarditis 3DTEE may have additional value compared to 2D echocardiography. © 2014, Wiley Periodicals, Inc.

  1. Semiautomated biventricular segmentation in three-dimensional echocardiography by coupled deformable surfaces.

    Science.gov (United States)

    Bersvendsen, Jørn; Orderud, Fredrik; Lie, Øyvind; Massey, Richard John; Fosså, Kristian; Estépar, Raúl San José; Urheim, Stig; Samset, Eigil

    2017-04-01

    With the advancement of three-dimensional (3-D) real-time echocardiography in recent years, automatic creation of patient specific geometric models is becoming feasible and important in clinical decision making. However, the vast majority of echocardiographic segmentation methods presented in the literature focus on the left ventricle (LV) endocardial border, leaving segmentation of the right ventricle (RV) a largely unexplored problem, despite the increasing recognition of the RV's role in cardiovascular disease. We present a method for coupled segmentation of the endo- and epicardial borders of both the LV and RV in 3-D ultrasound images. To solve the segmentation problem, we propose an extension of a successful state-estimation segmentation framework with a geometrical representation of coupled surfaces, as well as the introduction of myocardial incompressibility to regularize the segmentation. The method was validated against manual measurements and segmentations in images of 16 patients. Mean absolute distances of [Formula: see text], [Formula: see text], and [Formula: see text] between the proposed and reference segmentations were observed for the LV endocardium, RV endocardium, and LV epicardium surfaces, respectively. The method was computationally efficient, with a computation time of [Formula: see text].

  2. Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography.

    Science.gov (United States)

    Jánosi, Rolf Alexander; Kahlert, Philipp; Plicht, Björn; Wendt, Daniel; Eggebrecht, Holger; Erbel, Raimund; Buck, Thomas

    2011-04-01

    We sought to determine the level of agreement and the reproducibility of two-dimensional (2D) transthoracic (2D-TTE), 2D transesophageal (2D-TEE) and real-time three-dimensional (3D) transesophageal echocardiography (RT3D-TEE) for measurement of aortic annulus size in patients referred for transcatheter aortic valve implantation (TAVI). Accurate preoperative assessment of the dimensions of the aortic annulus is critical for patient selection and successful implantation in those undergoing TAVI for severe aortic stenosis (AS). Annulus size was measured using 2D-TTE, 2D-TEE and RT3D-TEE in 105 patients with severe AS referred for TAVI. Agreement between echocardiographic methods and interobserver variability was assessed using the Bland-Altman method and regression analysis, respectively. The mean aortic annuli were 21,7 ± 3 mm measured with 2D-TTE, 22,6 ± 2,8 mm with 2D-TEE and 22,3 ± 2,9 mm with RT3D-TEE. The results showed a small but significant mean difference and a strong correlation between the three measurement techniques (2D-TTE vs. 2D-TEE mean difference 0,84 ± 1,85 mm, r = 0,8, p annulus measured by 2D-TTE, 2D-TEE and RT3D-TEE. Thus, in patients referred for TAVI, the echocardiographic method used may have an impact on TAVI strategy.

  3. Three-dimensional echocardiography in congenital heart disease : an expert consensus document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography

    NARCIS (Netherlands)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark; Khoo, Nee; Ko, Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie; Meijboom, Folkert|info:eu-repo/dai/nl/136537367; Roberson, David; Van den Bosch, Annemien; Miller, Owen; Shirali, Girish

    2016-01-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good

  4. Three-dimensional Echocardiography in Congenital Heart Disease : An Expert Consensus Document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography

    NARCIS (Netherlands)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark K; Khoo, Nee S; Ko, Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie S; Meijboom, Folkert|info:eu-repo/dai/nl/136537367; Roberson, David; van den Bosch, Annemien E; Miller, Owen; Shirali, Girish

    2017-01-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good

  5. Three-dimensional Echocardiography in Congenital Heart Disease : An Expert Consensus Document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography

    NARCIS (Netherlands)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark K; Khoo, Nee S; Ko, Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie S; Meijboom, Folkert; Roberson, David; van den Bosch, Annemien E; Miller, Owen; Shirali, Girish

    2017-01-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good ac

  6. Three-dimensional echocardiography in congenital heart disease : an expert consensus document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography

    NARCIS (Netherlands)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark; Khoo, Nee; Ko, Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie; Meijboom, Folkert|info:eu-repo/dai/nl/136537367; Roberson, David; Van den Bosch, Annemien; Miller, Owen; Shirali, Girish

    2016-01-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good ac

  7. Three-dimensional echocardiography in congenital heart disease : an expert consensus document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography

    NARCIS (Netherlands)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark; Khoo, Nee; Ko, Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie; Meijboom, Folkert; Roberson, David; Van den Bosch, Annemien; Miller, Owen; Shirali, Girish

    2016-01-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good ac

  8. The Early Variation of Left Ventricular Strain after Aortic Valve Replacement by Three-Dimensional Echocardiography.

    Directory of Open Access Journals (Sweden)

    Yongle Chen

    Full Text Available Aortic stenosis (AS and aortic incompetence (AI are common aortic valve diseases. Both may deteriorate into irreversible myocardial dysfunction and will increase the risk of sudden death. In this study, we aimed to investigate the early variation trend of left ventricular function by three-dimensional speckle tracking echocardiography (3D-STE in the patients who underwent cardiac surgeries for aortic valve disease. Twenty patients with severe aortic AS and 16 patients with severe AI were enrolled. All of them underwent the aortic valve replacement (AVR procedures. The patients' global longitudinal strain (GLS and global circumferential strain (GCS were evaluated by 3D-STE before surgery and at 1 week after surgery. In addition, GLS and GCS were followed at 1 month as well as 3 months after AVR. In AS patients, the GCS after AVR altered little both at 1 week (p = 0.562 and at 1 month (p = 0.953 compared with the data before the surgery. And it increased significantly at 3 months of follow-up observation compared to that before AVR (p<0.05. Meanwhile, GLS increased progressively after AVR and improved significantly at 3 months after surgery (p<0.05. For the AI patients, GLS as well as GCS decreased at 1 week after AVR compared to those data at baseline (p<0.05. However, these two parameters recovered at 1 month after AVR. Furthermore, GLS and GCS improved significantly at 3 months after the surgery (p<0.05. Therefore, both GLS and GCS were influenced by AVR and would be improved at 3 months after surgery both in AS patients or AI patients. GLS and GCS can be finely evaluated by 3D-STE, and they are helpful to determine the variation tendency of left ventricular function in patients with AVR.

  9. Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography

    Institute of Scientific and Technical Information of China (English)

    WANG Jing; WANG Xinfang; XIE Mingxing; YANG Ya; LV Qing; YANG Ying; WANG Liangyu

    2005-01-01

    The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV "Full volume" images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpsons rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25-0. 0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0. 001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0. 986, P<0. 001; r=0.93, P<0. 001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RVs complex shape,apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function.

  10. Right heart function assessment with real-time three-dimensional echocardiography before and after atrial septal defect surgery

    Institute of Scientific and Technical Information of China (English)

    Hua Zhao; Yi-Min Fu; Yong-Mei Jia

    2016-01-01

    Objective:To study the clinical value of right heart function assessment with real-time three-dimensional echocardiography before and after atrial septal defect surgery. Methods:Patients with atrial septal defect who received transcatheter closure in our hospital were selected for study and divided into non-pulmonary hypertension group and pulmonary hypertension group according to pulmonary artery systolic pressure (PASP), real-time three-dimensional echocardiography was conducted before and after operation, and right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV), right ventricular stroke volume (RVSV), right ventricular ejection fraction (RVEF) and right ventricular cardiac output (RVCO) were calculated;serum was collected, and brain natriuretic peptide (BNP), atrial natriuretic peptide (ANP), angiotensin I (AngI), angiotensin II (AngII) and endothelin (ET) contents were detected. Results:After operation, RVEDV, RVESV, RVSV, RVEF and RVCO as well as serum BNP, ANP, AngI, AngII and ET contents of both groups were lower than those before treatment;RVEDV, RVESV, RVSV, RVEF and RVCO were positively correlated with contents of BNP, ANP, AngI, AngII and ET. Conclusions:Using real-time three-dimensional echocardiography before and after atrial septal defect surgery can accurately assess right heart function, and it has good correlation with right heart volume load and pulmonary circulation blood flow.

  11. Left ventricular myocardial function in hemodialysis and nondialysis uremia patients: a three-dimensional speckle-tracking echocardiography study.

    Directory of Open Access Journals (Sweden)

    Ran Chen

    Full Text Available BACKGROUND: Several studies have demonstrated that uremic patients who have preserved left ventricular ejection fraction (LVEF could still have the potential for systolic dysfunction. The aim of this study was to assess the differences between the left ventricular (LV myocardial function in hemodialysis and nondialysis uremic patients based on three-dimensional speckle-tracking echocardiography. METHODS: The study population consisted of 35 maintenance hemodialysis patients (the hemodialysis group, 30 uremic patients who were hospitalized for the creation of a primary arteriovenous fistula (the nondialysis group, and 32 healthy volunteers. All of the patients had normal left ventricular ejection fractions (i.e., 55% or greater. Three-dimensional speckle tracking echocardiography was performed to assess the left ventricle's global three-dimensional strain, regional longitudinal strain, circumferential strain, and radial strain. RESULTS: The left ventricular regional longitudinal strain, radial strain, circumferential strain, and global three-dimensional strain were significantly decreased in the nondialysis patients compared with the other two groups (all, P<0.001. However, the three-dimensional strain and the regional longitudinal strain were lower in the hemodialysis patients than in the controls (P<0.01. In the hemodialysis patients and the control group, the longitudinal strain, circumferential strain, and radial strain were higher at the apical level than they were at the basal level and midlevels. A multivariate linear regression analysis showed that the blood urea nitrogen and creatinine levels were independently associated with the values of the global three-dimensional strain (β = -0.217, P = 0.000; β = -0.243, P = 0.011, respectively and the longitudinal strain (β = -0.154, P = 0.032; β = -0.188, P = 0.029, respectively. CONCLUSIONS: Three-dimensional speckle-tracking echocardiography may detect

  12. Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects

    Institute of Scientific and Technical Information of China (English)

    CHEN Li-xin 陈立新; YANG Ying 杨颖; FEI Hong-wen 费洪文; WANG Liang-yu 王良玉; WANG Xin-fang 王新房; Navin C Nanda; Andrew P Miller; XIE Ming-xing 谢明星; ZHUANG Lei 庄磊; YANG Ya 杨娅; WANG Jing 王静; HUANG Run-qing 黄润青

    2004-01-01

    Background Both real-time three-dimensional echocardiography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects.Methods Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n=6) or distal branch of the left circumflex artery (LCX, n=7) under general anaesthesia. Three to four ml of a perfluoropropane (C3F8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and right coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals' hearts were used as controls.Results Left ventricular (LV) mass determined by RT3DE ranged 36.7-68.9 g [mean, (54.6±9.6) g] before coronary artery ligation, and correlated highly (r=0.99) with in vitro measurement of LV mass [range, 38.9-71.1 g; mean, (55.6±9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7-68.9 g; mean, (51.3±12.5) g. Or range, 38.9-71.1 g; mean, (53.7±12.3) g, respectively] and under-perfused mass [range, 0-21.4 g; mean, (12.0±6.9) g. Or range, 0-19.8 g; mean, (10.8±6.3) g, respectively] after the LAD ligation (P>0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1-65.4 g; mean, (57.5±5.9) g. Or range, 51.5-65.8 g; mean, (57.3±6.4) g, respectively] and under-perfused mass [range, 0-25.6 g; mean, (13.3±9.6) g. Or range, 0-22.7 g; mean, (12.8±8.1) g, respectively] after the LCX ligation (P>0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9-68.6 g [mean, (54.8±10.0) g] and there was

  13. QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    Lei Zhuang; Ming-xing Xie; Wei-juan Wang; Xiang-xin Yang; Tao Liu

    2006-01-01

    Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3 DE).Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD,n=14) or distal branch of the left circumflex artery (LCX,n=7).A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal's heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38. 9 to78.5 (mean±SD: 60.0±10.1)g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x).Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.

  14. Dynamic three-dimensional echocardiography combined with semi-automated border detection offers advantages for assessment of resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Voormolen Marco M

    2003-10-01

    Full Text Available Abstract Simultaneous electrical stimulation of both ventricles in patients with interventricular conduction disturbance and advanced heart failure improves hemodynamics and results in increased exercise tolerance, quality of life. We have developed a novel technique for the assessment and optimization of resynchronization therapy. Our approach is based on transthoracic dynamic three-dimensional (3D echocardiography and allows determination of the most delayed contraction site of the left ventricle (LV together with global LV function data. Our initial results suggest that fast reconstruction of the LV is feasible for the selection of the optimal pacing site and allows identifying LV segments with dyssynchrony.

  15. Echocardiography derived three-dimensional printing of normal and abnormal mitral annuli

    Directory of Open Access Journals (Sweden)

    Feroze Mahmood

    2014-01-01

    Full Text Available Aims and Objectives: The objective of this study was to assess the clinical feasibility of using echocardiographic data to generate three-dimensional models of normal and pathologic mitral valve annuli before and after repair procedures. Materials and Methods: High-resolution transesophageal echocardiographic data from five patients was analyzed to delineate and track the mitral annulus (MA using Tom Tec Image-Arena software. Coordinates representing the annulus were imported into Solidworks software for constructing solid models. These solid models were converted to stereolithographic (STL file format and three-dimensionally printed by a commercially available Maker Bot Replicator 2 three-dimensional printer. Total time from image acquisition to printing was approximately 30 min. Results: Models created were highly reflective of known geometry, shape and size of normal and pathologic mitral annuli. Post-repair models also closely resembled shapes of the rings they were implanted with. Compared to echocardiographic images of annuli seen on a computer screen, physical models were able to convey clinical information more comprehensively, making them helpful in appreciating pathology, as well as post-repair changes. Conclusions: Three-dimensional printing of the MA is possible and clinically feasible using routinely obtained echocardiographic images. Given the short turn-around time and the lack of need for additional imaging, a technique we describe here has the potential for rapid integration into clinical practice to assist with surgical education, planning and decision-making.

  16. Echocardiography derived three-dimensional printing of normal and abnormal mitral annuli.

    Science.gov (United States)

    Mahmood, Feroze; Owais, Khurram; Montealegre-Gallegos, Mario; Matyal, Robina; Panzica, Peter; Maslow, Andrew; Khabbaz, Kamal R

    2014-01-01

    The objective of this study was to assess the clinical feasibility of using echocardiographic data to generate three-dimensional models of normal and pathologic mitral valve annuli before and after repair procedures. High-resolution transesophageal echocardiographic data from five patients was analyzed to delineate and track the mitral annulus (MA) using Tom Tec Image-Arena software. Coordinates representing the annulus were imported into Solidworks software for constructing solid models. These solid models were converted to stereolithographic (STL) file format and three-dimensionally printed by a commercially available Maker Bot Replicator 2 three-dimensional printer. Total time from image acquisition to printing was approximately 30 min. Models created were highly reflective of known geometry, shape and size of normal and pathologic mitral annuli. Post-repair models also closely resembled shapes of the rings they were implanted with. Compared to echocardiographic images of annuli seen on a computer screen, physical models were able to convey clinical information more comprehensively, making them helpful in appreciating pathology, as well as post-repair changes. Three-dimensional printing of the MA is possible and clinically feasible using routinely obtained echocardiographic images. Given the short turn-around time and the lack of need for additional imaging, a technique we describe here has the potential for rapid integration into clinical practice to assist with surgical education, planning and decision-making.

  17. Three-dimensional Echocardiography in Congenital Heart Disease: An Expert Consensus Document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography.

    Science.gov (United States)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark K; Khoo, Nee S; Ko, H Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie S; Meijboom, Folkert; Roberson, David; Van den Bosch, Annemien; Miller, Owen; Shirali, Girish

    2017-01-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good acoustic windows and the non-invasive nature of the technique. The aim of this paper is to provide a review of the optimal application of 3DE in CHD including technical considerations, image orientation, application to different lesions, procedural guidance, and functional assessment. Copyright © 2016 European Society of Cardiology. Published by Elsevier Inc. All rights reserved.

  18. Real time three-dimensional transthoracic echocardiography of ruptured left sinus of Valsalva aneurysm to left ventricle.

    Science.gov (United States)

    Kharwar, Rajiv Bharat; Narain, Varun Shankar; Sethi, Rishi

    2013-11-01

    Aneurysms arising from the sinus of Valsalva are a rare cardiac defect that can present with various signs and symptoms, and if not diagnosed and treated rapidly can lead to fatal outcomes. Unruptured aneurysms are usually asymptomatic and found incidentally during diagnostic studies. More commonly, aneurysm of sinus of Valsalva is detected after the occurrence of rupture. Echocardiography has become the investigative tool of choice for this condition, not only for diagnosis but also for quantification of severity. We hereby report a rare case of a 15-year-old patient presenting with complaints of effort dyspnea and palpitations. Two-dimensional transthoracic echocardiography (TTE) showed aneurysmal dilatation of left sinus of Valsalva which had ruptured into the left ventricle. Also, there was an intimal flap within the sinus of Valsalva aneurysm. The anatomical relationship between the aorta, aneurysm, and the left ventricle as well as the intimal flap within the aneurysm was clearly delineated with the help of three-dimensional TTE. After confirmation of the diagnosis with multidetector computed tomography, patient underwent successful surgical repair of the defect.

  19. Three-dimensional Speckle Tracking Echocardiography in Light Chain Cardiac Amyloidosis: Examination of Left and Right Ventricular Myocardial Mechanics Parameters.

    Science.gov (United States)

    Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R

    2015-08-01

    The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by

  20. Three-dimensional echocardiography in congenital heart disease: an expert consensus document from the European Association of Cardiovascular Imaging and the American Society of Echocardiography.

    Science.gov (United States)

    Simpson, John; Lopez, Leo; Acar, Philippe; Friedberg, Mark; Khoo, Nee; Ko, Helen; Marek, Jan; Marx, Gerald; McGhie, Jackie; Meijboom, Folkert; Roberson, David; Van den Bosch, Annemien; Miller, Owen; Shirali, Girish

    2016-10-01

    Three-dimensional echocardiography (3DE) has become important in the management of patients with congenital heart disease (CHD), particularly with pre-surgical planning, guidance of catheter intervention, and functional assessment of the heart. 3DE is increasingly used in children because of good acoustic windows and the non-invasive nature of the technique. The aim of this paper is to provide a review of the optimal application of 3DE in CHD including technical considerations, image orientation, application to different lesions, procedural guidance, and functional assessment. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  1. A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study

    Directory of Open Access Journals (Sweden)

    Hani M. Mahmoud

    2015-01-01

    Full Text Available Aim of Study. To assess the feasibility of a new proposed maneuver “RATLe-90” using real-time three-dimensional transesophageal echocardiography (RT-3DTEE for anatomically oriented visualization of the interatrial septum (IAS in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2±6.7 years; 60% males who underwent TSP for different indications. RT-3DTEE was used to guide TSP. The proposed maneuver RATLe-90 (Rotate-Anticlockwise-Tilt-Left-90 was applied in all cases to have the anatomically oriented en face view of the IAS from the right atrial (RA aspect. Having this anatomically oriented view, we guided the TSP catheter towards the proper puncture site according to the planned procedure. Results. Using the RATLe-90 maneuver, the anatomically oriented en face view of the IAS from the RA was obtained in all patients. We were able to guide the puncture catheter to the proper puncture site on the IAS. The 3D images obtained were clearly understood by both echocardiographers and interventionists. The RATLe-90 maneuver acquisition time was 19.9±1.6 seconds. The time-to-tent was 64.8±16.3 seconds. Less TEE probe manipulations were needed while guiding the TSP. Conclusions. Application of RT3D-TEE during TSP using RATLe-90 maneuver is feasible with shorter fluoroscopy time and minimizing TEE probe manipulations.

  2. Evaluation of myocardial infarction size with three-dimensional speckle tracking echocardiography: a comparison with single photon emission computed tomography.

    Science.gov (United States)

    Wang, Qiushuang; Zhang, Chunhong; Huang, Dangsheng; Zhang, Liwei; Yang, Feifei; An, Xiuzhi; Ouyang, Qiaohong; Zhang, Meiqing; Wang, Shuhua; Guo, Jiarui; Ji, Dongdong

    2015-12-01

    To assess whether global and regional myocardial strains from three-dimensional speckle tracking echocardiography (3D-STE) correlate with myocardial infarction size (MIS) detected by single photon emission computed tomography (SPECT). Fifty-seven patients with a history of ST-segment elevation myocardial infarction (MI) within 3-6 months were enrolled, alongside 24 healthy volunteers. Left ventricular (LV) global area strain, global longitudinal strain (GLS), global radial strain, global circumferential strain, left ventricular ejection fraction (LVEF) and wall motion score index (WMSI) were measured and compared with the corresponding SPECT-detected MISs. Patients were sub-grouped into massive MIS group (MIS ≥ 12%) and small MIS group (MIS Myocardial strains of all the LV segments were compared with the corresponding MIS. Global myocardial strain parameters, LVEF and WMSI of the patients were significantly different from the control group (all P myocardial strain parameters were found between the massive and small MIS groups (all P myocardial strain parameters were observed between segments with and without transmural MIs (P myocardial strain parameters evaluated LV global MIS, 3D GLS had the highest diagnostic value. It also preliminarily gauged the degree of ischemia and necrosis of regional myocardial segments.

  3. [Assessment right atrial function in patients with systemic lupus erythematosus by speckle tracking and three-dimensional echocardiography].

    Science.gov (United States)

    Ge, X Y; Shao, L; Zheng, Z L

    2016-12-20

    Objective: To evaluate right atrial function in systemic lupus erythematosus (SLE) with normal pulmonary pressure by using two dimensional-speckle tracking imaging (2D-STI) and real-time three-dimensional echocardiography(RT-3DE). Methods: A totoal of 40 patients with SLE and 40 control subjects were collected between December 2011 and May 2014 from Ningbo Medical Treatment Center Lihuili Hospital. Right atrial global longitudinal strain (RAGLS) and all kinds of right atrium volume index (RAVI) were detected. Relationship between tricuspid annular plane systolic excursion(TAPSE), tricuspid annulus systolic peak velocity (S'), right ventricular myocardial performance index (RVMPI), ETV/e'TV and the right atrium parameters were analyzed. Results: SLE group's right atrium maximal volume index(RAVImax)(33.5±11.1) ml/m(2,) right atrium minimal volume index (RAVImin)(13.2±4.5) ml/m(2,) right atrium presystolic volume index (RAVIpre) (2.57±10.2) ml/m(2,) right atrium total emptying volume index(RAVIt)(20.2±8.1)ml/m(2,) right atrium active emptying volume index (RAVIa)(12.5±7.5) ml/m(2)) were increased .But right atrium passive emptying volume index(RAVIp)( 7.8±2.7) ml/m(2) and right atrial global longitudinal strain (RAGLS) (38.2%±7.7% ) were decreased (both Pright atrial function by 2D-STI and RT-3DE could diagnose right atrial dysfunction in early stage of SLE patients with normal pulmonary pressure. The method is simple, has significant clinical value.

  4. Coexisting bicuspid aortic and pulmonary valves with normally related great vessels diagnosed by live/real time three-dimensional transesophageal echocardiography.

    Science.gov (United States)

    Kemaloğlu Öz, Tuğba; Karadeniz, Fatma Özpamuk; Gundlapalli, Hareesh; Erer, Betul; Sharma, Rohit K; Ahmed, Mustafa; Nanda, Navin C; Yıldırım, Aydın; Orhan, Gökçen; Öz, Ayhan; Eren, Mehmet

    2014-02-01

    Coexistence of bicuspid aortic and pulmonary valves in the same patient is a very rare entity identified mainly during surgery and postmortem. To the best of our knowledge, only one case has been diagnosed by two-dimensional echocardiography in a newborn with malposition of the great arteries but no images were presented. Here, we are reporting the first case of bicuspid pulmonary and aortic valves diagnosed by live/real time three-dimensional transesophageal echocardiography in an adult with normally related great arteries. © 2014, Wiley Periodicals, Inc.

  5. Validation of admittance computed left ventricular volumes against real-time three-dimensional echocardiography in the porcine heart.

    Science.gov (United States)

    Kutty, Shelby; Kottam, Anil T; Padiyath, Asif; Bidasee, Keshore R; Li, Ling; Gao, Shunji; Wu, Juefei; Lof, John; Danford, David A; Kuehne, Titus

    2013-06-01

    The admittance and Wei's equation is a new technique for ventricular volumetry to determine pressure-volume relations that addresses traditional conductance-related issues of parallel conductance and field correction factor. These issues with conductance have prevented researchers from obtaining real-time absolute ventricular volumes. Moreover, the time-consuming steps involved in processing conductance catheter data warrant the need for a better catheter-based technique for ventricular volumetry. We aimed to compare the accuracy of left ventricular (LV) volumetry between the new admittance catheterization technique and transoesophageal real-time three-dimensional echocardiography (RT3DE) in a large-animal model. Eight anaesthetized pigs were used. A 7 French admittance catheter was positioned in the LV via the right carotid artery. The catheter was connected to an admittance control unit (ADVantage; Transonic Scisense Inc.), and data were recorded on a four-channel acquisition system (FA404; iWorx Systems). Admittance catheterization data and transoesophageal RT3DE (X7-2; Philips) data were simultaneously obtained with the animal ventilated, under neuromuscular blockade and monitored in baseline conditions and during dobutamine infusion. Left ventricular volumes measured from admittance catheterization (Labscribe; iWorx Systems) and RT3DE (Qlab; Philips) were compared. In a subset of four animals, admittance volumes were compared with those obtained from traditional conductance catheterization (MPVS Ultra; Millar Instruments). Of 37 sets of measurements compared, admittance- and RT3DE-derived LV volumes and ejection fractions at baseline and in the presence of dobutamine exhibited general agreement, with mean percentage intermethod differences of 10% for end-diastolic volumes, 14% for end-systolic volumes and 9% for ejection fraction; the respective intermethod differences between admittance and conductance in eight data sets compared were 11, 11 and 12

  6. New three-dimensional speckle-tracking echocardiography identifies global impairment of left ventricular mechanics with a high sensitivity in childhood cancer survivors.

    Science.gov (United States)

    Yu, Hong-kui; Yu, Wei; Cheuk, Daniel K L; Wong, Sophia J; Chan, Godfrey C F; Cheung, Yiu-fai

    2013-08-01

    The aim of this case-control study was to assess the usefulness of three-dimensional (3D) speckle-tracking echocardiography in the evaluation of global left ventricular (LV) myocardial performance in adolescent and adult survivors of childhood cancers. Fifty-three anthracycline-treated survivors of childhood cancers (mean age, 18.6 ± 5.1 years) and 38 controls were studied. Three-dimensional speckle-tracking echocardiography was performed to assess LV 3D global and segmental strain, time to peak segmental 3D strain, LV torsion, and ejection fraction. LV systolic dyssynchrony index (SDI) was calculated as the percentage of the standard deviation of times to peak strain of the 16 segments divided by the RR interval. A global performance index (GPI) was calculated as (global 3D strain × torsion)/SDI. The area under the receiver operating characteristic curve was calculated to determine the capability of various echocardiographic indices to discriminate between patients and controls. Compared with controls, patients had significantly reduced LV global 3D strain (P speckle-tracking echocardiography enables the derivation of an index of LV global performance that incorporates LV 3D strain, dyssynchrony, and torsion for the sensitive detection of altered LV mechanics in childhood cancer survivors. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  7. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice.

  8. Three-dimensional echocardiography with tissue harmonic imaging shows excellent reproducibility in assessment of left ventricular volumes

    DEFF Research Database (Denmark)

    Kim, Won Yong; Søgaard, Peter; Egeblad, Henrik;

    2001-01-01

    We studied the reproducibility of repeated measurements of left ventricular (LV) volumes by 2-dimensional (biplane method of disks) and 3-dimensional echocardiography (coaxial scanning) with tissue harmonic imaging. Ten healthy subjects underwent estimation of LV volumes by transthoracic echocard......We studied the reproducibility of repeated measurements of left ventricular (LV) volumes by 2-dimensional (biplane method of disks) and 3-dimensional echocardiography (coaxial scanning) with tissue harmonic imaging. Ten healthy subjects underwent estimation of LV volumes by transthoracic...

  9. Three-dimensional propagation imaging of left ventricular activation by speckle-tracking echocardiography to predict responses to cardiac resynchronization therapy.

    Science.gov (United States)

    Seo, Yoshihiro; Ishizu, Tomoko; Kawamura, Ryo; Yamamoto, Masayoshi; Kuroki, Kenji; Igarashi, Miyako; Sekiguchi, Yukio; Nogami, Akihiko; Aonuma, Kazutaka

    2015-05-01

    On the basis of the electromechanical coupling theory, an activation imaging system has been developed with three-dimensional speckle-tracking echocardiography. The aim of this study was to determine the association between left ventricular (LV) propagation patterns by activation imaging and response to cardiac resynchronization therapy (CRT). This was a retrospective, single-center study. Eighty-one patients undergoing CRT, of whom 50 (61.7%) had left bundle branch block (LBBB), were enrolled. Activation imaging studies were performed with a three-dimensional speckle-tracking echocardiographic system, which allowed visualization of LV activation propagation and measurement of the time from the QRS complex to activation onset. A CRT volume responder was defined as a patient with ≥15% reduction of LV end-systolic volume at 6 months after CRT. Clinical outcomes were assessed with the composite end point of death due to cardiac causes or unplanned hospitalization for cardiac diseases. In patients with LBBB, the main activation pattern (74%) was a U-shaped propagation pattern, which was characterized as propagation from the midseptum to the lateral or posterior wall through the apex. In patients without LBBB, various non-U-shaped propagation patterns were observed in the majority of patients (97%). Among the 41 CRT responders, almost all (87.8%) had the U-shaped propagation pattern. During follow-up (median, 20 months), 29 patients (35.8%) reached the clinical end points. In a multivariate Cox proportional hazards model, a U-shaped propagation pattern was associated with the end points independently of LBBB or LV end-diastolic volume. The U-shaped propagation pattern on three-dimensional speckle-tracking echocardiography was significantly associated with a favorable CRT response. Activation pattern analysis may provide additional information to predict response to CRT. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights

  10. Evaluation value of real-time three-dimensional adenosine stress echocardiography and coronary angiography for patients with stable angina pectoris

    Institute of Scientific and Technical Information of China (English)

    Ya-Li Wu; Nan-Jue Jiang; Yan Cai

    2016-01-01

    Objective:To study the evaluation value of real-time three-dimensional adenosine stress echocardiography and coronary angiography for patients with stable angina pectoris. Methods:A total of 45 patients diagnosed with stable angina pectoris in our hospital between May 2014 and December 2015 were selected as the stable angina pectoris group (SAP group) of the study and 50 healthy subjects receiving physical examination in our hospital during the same period were selected as control group. Real-time three-dimensional adenosine stress echocardiography was performed to measure coronary flow reserve (CFR), serum was collected to determine lipid metabolism indexes and inflammation indexes, and peripheral blood mononuclear cells were collected to determine the expression levels of inflammatory regulatory molecules.Results:CFR of SAP group was significantly lower than that of control group and the more the number of coronary lesions, the lower the CFR of SAP group; serum Lp(a), LDL-C, ApoB, MIF-1α, ICAM-1, VCAM-1, CD40 and CD40L content as well as the fluorescence intensity of peripheral blood mononuclear cell surface TLR4 and NF-κB of SAP group were significantly higher than those of control group and negatively correlated with CFR level while serum HDL-C and ApoA1 content as well as the fluorescence intensity of peripheral blood mononuclear cell surface TIPE2 and BACH2 were significantly lower than those of control group and positively correlated with CFR level.Conclusion:CFR measured by real-time three-dimensional adenosine stress echocardiography significantly reduces in patients with stable angina pectoris and is correlated with lipid metabolism state and the degree of inflammation.

  11. Assessment value of real-time three-dimensional echocardiography on right ventricular systolic function in patients with tetralogy of Fallot

    Institute of Scientific and Technical Information of China (English)

    Jin-Hua Su; Hai-Yan Kou; Li Liang

    2016-01-01

    Objective:To analyze the assessment value of real-time three-dimensional echocardiography on right ventricular systolic function in patients with tetralogy of Fallot (TOF).Methods:63 cases of children with tetralogy of Fallot undergoing surgical treatment in our hospital from September 2011 to September 2014 were chosen as observation group, 72 cases of normal children receiving health examination in our hospital during the same period were chosen as normal control group, all of them received two-dimensional and three-dimensional ultrasound examination, and right ventricular systolic function of TOF children was compared and observed.Results:1) TOF patients’ preoperative left pulmonary artery inner diameter was 5.38–9.65 mm, right pulmonary artery inner diameter was 5.34–9.15 mm, average pulmonary artery index (Nakata index) was (160.92±21.58) mm2/m2; 2) TOF patients’ preoperative RVEDV and RVESV values were greater than those of normal control group and RVEF value was less than that of normal control group (P<0.05); RVEDV and RVESV 6 months after surgery increased, RVEF decreased, and compared with before surgery, there was significant difference (P<0.05); 3) TOF patients’ preoperative three-dimensional ultrasound RVESV and RVEDV values were higher than results of two-dimensional ultrasound examination (P<0.05); 4) TOF patients’ preoperative RVEF had significant positive correlation with Nakata index, r=0.653 (P<0.05).Conclusions: Real-time three-dimensional echocardiography can accurately and objectively assess right ventricular systolic function in patients with Tetralogy of Fallot, and contributes to the assessment of treatment effect and long-term prognosis.

  12. Incremental value of live/real time three-dimensional transesophageal echocardiography over the two-dimensional technique in the assessment of aortic atherosclerotic thrombi and ulcers.

    Science.gov (United States)

    Elsayed, Mahmoud; Bulur, Serkan; Kalla, Aditi; Ahmed, Mustafa I; Hsiung, Ming C; Uygur, Begum; Alagic, Nermina; Sungur, Aylin; Singh, Satinder; Nanda, Navin C

    2016-08-01

    We present two cases in whom live/real time three-dimensional transesophageal echocardiography (3DTEE) provided incremental value in the assessment of atherosclerotic disease in the aorta. In one patient, it identified additional atherosclerotic ulcers as well as thrombi within them which were missed by two-dimensional (2D) TEE. In both cases, the size of the large mobile atherosclerotic plaque was underestimated by 2DTEE as compared with 3DTEE. Furthermore, 3DTEE provided volume quantification of the thrombi and ulcers which is not possible by 2DTEE. The echocardiographic findings of atherosclerotic plaques were confirmed by computed tomography in one patient and by surgery in the other.

  13. Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function

    Directory of Open Access Journals (Sweden)

    Cosyns Bernard

    2009-06-01

    Full Text Available Abstract Background In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF and left ventricular (LV volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV of the group by scintigraphy was 143 ± 65 mL and was underestimated by triplane contrast RT3DE (128 ± 60 mL; p Conclusion Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease.

  14. Deformation imaging and three-dimensional echocardiography : implications on clinical management of patients with ischemic heart disease

    NARCIS (Netherlands)

    Hoogslag, Georgette Elise

    2016-01-01

    Evaluation of patients with ischemic heart disease using echocardiography is indispensable. Both in the acute setting of STEMI, at follow-up and in the chronic phase during the possible development of heart failure, routine echocardiographic assessment is an essential part of daily clinical

  15. Additional value of three-dimensional transesophageal echocardiography for patients with mitral valve stenosis undergoing balloon valvuloplasty.

    Science.gov (United States)

    Langerveld, Jorina; Valocik, Gabriel; Plokker, H W Thijs; Ernst, Sjef M P G; Mannaerts, Herman F J; Kelder, Johannes C; Kamp, Otto; Jaarsma, Wybren

    2003-08-01

    The objective of this study was to validate the additional value of 3-dimensional (3D) transesophageal echocardiography (TEE) for patients with mitral valve stenosis undergoing percutaneous mitral balloon valvotomy (PTMV). Therefore, in a series of 21 patients with severe mitral valve stenosis selected for PTMV, 3D TEE was performed before and after PTMV. The mitral valve area was assessed by planimetry pre- and post-PTMV; the mitral valve volume was assessed and attention was paid to the amount of fusion of the commissures. These results were compared with findings by 2-dimensional transthoracic echocardiography using pressure half-time method for assessment of mitral valve area, and were analyzed for the prediction of successful outcome. Pre-PTMV the mitral valve area assessed by 3D TEE was 1.0 +/- 0.3 cm(2) vs 1.2 +/- 0.4 cm(2) assessed by 2-dimensional transthoracic echocardiography (P =.03) and post-PTMV it was 1.8 +/- 0.5 cm(2) vs 1.9 +/- 0.6 cm(2) (not significant), respectively. The mitral valve volume could be assessed by 3D TEE (mean 2.4 +/- 2.5 cm(3)) and was inversely correlated to a successful PTMV procedure (P <.001). The 3D TEE method enabled a better description of the mitral valvular anatomy, especially post-PTMV. We conclude that 3D TEE will have additional value over 2-dimensional echocardiography in this group of patients, for selection of patients pre-PTMV, and for analyzing pathology of the mitral valve afterward.

  16. Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function—Current Clinical Applications and Literature Review Update

    Science.gov (United States)

    Velasco, Omar; Beckett, Morgan Q.; James, Aaron W.; Loehr, Megan N.; Lewis, Taylor G.; Hassan, Tahmin; Janardhanan, Rajesh

    2017-01-01

    Abstract Our review of real-time three-dimensional echocardiography (RT3DE) discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE) in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV) function. Articles included perspective clinical studies and meta-analyses in the English language, and focused on the role of RT3DE in human subjects. Application of RT3DE includes analysis of the pericardium, right ventricular (RV) and LV cavities, wall motion, valvular disease, great vessels, congenital anomalies, and traumatic injury, such as myocardial contusion. RT3DE, through a transthoracic echocardiography (TTE), allows for increasingly accurate volume and valve motion assessment, estimated LV ejection fraction, and volume measurements. Chamber motion and LV mass approximation have been more accurately evaluated by RT3DE by improved inclusion of the third dimension and quantification of volumetric movement. Moreover, RT3DE was shown to have no statistical significance when comparing the ejection fractions of RT3DE to cardiac magnetic resonance (CMR). Analysis of RT3DE data sets of the LV endocardial exterior allows for the volume to be directly quantified for specific phases of the cardiac cycle, ranging from end systole to end diastole, eliminating error from wall motion abnormalities and asymmetrical left ventricles. RT3DE through TTE measures cardiac function with superior diagnostic accuracy in predicting LV mass, systolic function, along with LV and RV volume when compared with 2DE with comparable results to CMR.

  17. Evaluation of left ventricular rotation by two-dimensional speckle tracking method and real-time three-dimensional echocardiography: comparison with MRI tagging method.

    Science.gov (United States)

    Hayashi, Hidetaka; Izumi, Chisato; Takahashi, Shuichi; Uchikoshi, Masato; Yamazaki, Ryou; Asanuma, Toshihiko; Ishikura, Fuminobu; Beppu, Shintaro; Nakatani, Satoshi

    2011-09-01

    Recently, it has become possible to evaluate left ventricular (LV) torsion by two-dimensional (2D) speckle tracking images. However, LV torsion is a three-dimensional (3D) performance, which per se cannot be assessed by the 2D speckle tracking method. The present study investigated the accuracy of the 2D speckle tracking method and real-time 3D echocardiography in measuring LV rotation, comparing with the MRI tagging method. We assessed LV apical rotation using the 2D speckle tracking method, real-time 3D echocardiography, and MRI tagging method in 26 normal subjects, and compared the results of these three methods. LV apical rotation was measured just before the level in which the posterior papillary muscle was absorbed into the free wall. The degree of LV apical rotation evaluated by the 2D speckle tracking method (Δθ 2D) was significantly smaller than that evaluated by 3D echocardiography (Δθ 3D) and the MRI tagging method (Δθ MRI) (Δθ 2D 7.3 ± 2.8°; Δθ 3D 8.8 ± 3.4°; Δθ MRI 9.0 ± 3.4°; Δθ 2D vs. Δθ 3D, p = 0.0001; Δθ 2D vs. Δθ MRI, p speckle tracking method compared with the MRI tagging method, whereas it could be precisely measured by 3D echocardiography.

  18. Comprehensive assessment of biventricular function and aortic stiffness in athletes with different forms of training by three-dimensional echocardiography and strain imaging.

    Science.gov (United States)

    Vitarelli, Antonio; Capotosto, Lidia; Placanica, Giuseppe; Caranci, Fiorella; Pergolini, Mario; Zardo, Francesco; Martino, Francesco; De Chiara, Stefania; Vitarelli, Massimo

    2013-10-01

    Previous studies have shown distinct models of cardiac adaptations to the training in master athletes and different effects of endurance and strength-training on cardiovascular function. We attempted to assess left-ventricular (LV) function, aortic (Ao) function, and right-ventricular (RV) function in athletes with different forms of training by using three-dimensional (3D) echocardiography, tissue Doppler imaging (TDI) and speckle-tracking imaging (STI). We examined 35 male marathon runners (endurance-trained athletes, ETA), 35 powerlifting athletes (strength-trained athletes, STA), 35 martial arts athletes (mixed-trained athletes, MTA), and 35 sedentary untrained healthy men (controls, CTR). Two-dimensional and three-dimensional echocardiography were performed for the assessment of LV and RV systolic/diastolic function. LV and RV longitudinal strain (LS) and LV torsion (LVtor) were determined using STI (EchoPAC BT11, GE-Ultrasound). Maximum velocity of systolic wall expansion peaks (AoSvel) was determined using TDI. ETA experienced LV eccentric hypertrophy with increased 3D LV end-diastolic volume and mass and significant increase in peak systolic apical rotation and LVtor. In all groups of athletes, RV-LS was reduced at rest and improved after exercise. AoSvel was significantly increased in ETA and MTA and significantly decreased in STA compared with CTR. There were good correlations between LV remodelling and aortic stiffness values. Multivariate analysis showed aortic wall velocities to be independently related to LV mass index. In strength-trained, endurance-trained, and mixed-trained athletes, ventricular and vascular response assessed by 3DE, TDI, and STI underlies different adaptations of LV, RV, and aortic indexes.

  19. Roles of real-time three-dimensional transesophageal echocardiography in peri-operation of transcatheter left atrial appendage closure

    Science.gov (United States)

    Zhou, Qing; Song, Hongning; Zhang, Lan; Deng, Qing; Chen, Jinling; Hu, Bo; Wang, Yijia; Guo, Ruiqiang

    2017-01-01

    Abstract Left atrial appendage (LAA) closure is a new treatment option for the prevention of stroke in patients with nonvalvular atrial fibrillation (AF). Conventional 2-dimensional transesophageal echocardiography (2D TEE) has some limitations in the imaging assessment of LAA closure. Real-time 3-dimensional transesophageal echocardiography (RT-3D TEE) allows for detailed morphologic assessment of the LAA. In this study, we aim to determine the clinical values of RT-3D TEE in the periprocedure of LAA closure. Thirty-eight persistent or paroxysmal AF patients with indications for LAA closure were enrolled in this study. RT-3D TEE full volume data of the LAA were recorded before operation to evaluate the anatomic feature, the landing zone dimension, and the depth of the LAA. On this basis, selection of LAA closure device was carried out. During the procedure, RT-3D TEE was applied to guide the interatrial septal puncture, device operation, and evaluate the occlusion effects. The patients were follow-up 1 month and 3 months postclosure. Twenty-eight (73.7%) patients with AF received placement of LAA occlusion device under RT-3D TEE. Eleven cases with single-lobe LAAs were identified using RT-3D TEE, among which 4 showed limited depth. Seventeen cases showed bilobed or multilobed LAA. Seven cases received LAA closure using Lefort and 21 using LAmbre based on the 3D TEE and radiography. The landing zone dimension of the LAA measured by RT-3D TEE Flexi Slice mode was better correlated with the device size used for occlusion (r = 0.90) than 2D TEE (r = 0.88). The interatial septal puncture, the exchange of the sheath, as well as the release of the device were executed under the guidance of RT-3D TEE during the procedure. The average number of closure devices utilized for optimal plugging was (1.11 ± 0.31). There were no clinically unacceptable residual shunts, pericardial effusion, or tamponade right after occlusion. All the patients had the device well

  20. The impact of high-normal blood pressure on left ventricular mechanics: a three-dimensional and speckle tracking echocardiography study.

    Science.gov (United States)

    Tadic, Marijana; Majstorovic, Anka; Pencic, Biljana; Ivanovic, Branislava; Neskovic, Aleksandar; Badano, Luigi; Stanisavljevic, Dejana; Scepanovic, Radisav; Stevanovic, Predrag; Celic, Vera

    2014-04-01

    To assess the presence of subclinical left ventricular myocardial dysfunction in subjects with high-normal blood pressure (BP) and untreated arterial hypertension, using three-dimensional (3D) echocardiography strain analysis. This cross-sectional study included 49 subjects with optimal BP, 50 subjects with high-normal BP, and 50 newly diagnosed untreated hypertensive patients matched by gender and age. All the subjects underwent 24 h blood pressure monitoring and complete two-dimensional and 3D echocardiography examination. The enrolled subjects were grouped according to 24 h systolic BP values, dividing the subjects with optimal BP from those with high-normal BP and the hypertensive patients (cut-off values were 120 and 130 mmHg, respectively). 3D global longitudinal strain was significantly lower in the high-normal BP group and the hypertensive patients, in comparison with the optimal BP group (-20.5 ± 3.3 vs. -18.7 ± 2.8 vs. -17.6 ± 2.7%, p high-normal and the optimal BP groups (10.1° ± 2.4° vs. 10.8° ± 2.6° vs. 13.8° ± 3.1°, p high-normal BP group, to the hypertensive patients (-135 ± 35 vs. -118 ± 31 vs. -102 ± 27°/s, p high-normal BP suffered subclinical impairment of LV mechanics similar as the hypertensive patients.

  1. Quantification of mitral valve morphology with three-dimensional echocardiography--can measurement lead to better management?

    Science.gov (United States)

    Lee, Alex Pui-Wai; Fang, Fang; Jin, Chun-Na; Kam, Kevin Ka-Ho; Tsui, Gary K W; Wong, Kenneth K Y; Looi, Jen-Li; Wong, Randolph H L; Wan, Song; Sun, Jing Ping; Underwood, Malcolm J; Yu, Cheuk-Man

    2014-01-01

    The mitral valve (MV) has complex 3-dimensional (3D) morphology and motion. Advance in real-time 3D echocardiography (RT3DE) has revolutionized clinical imaging of the MV by providing clinicians with realistic visualization of the valve. Thus far, RT3DE of the MV structure and dynamics has adopted an approach that depends largely on subjective and qualitative interpretation of the 3D images of the valve, rather than objective and reproducible measurement. RT3DE combined with image-processing computer techniques provides precise segmentation and reliable quantification of the complex 3D morphology and rapid motion of the MV. This new approach to imaging may provide additional quantitative descriptions that are useful in diagnostic and therapeutic decision-making. Quantitative analysis of the MV using RT3DE has increased our understanding of the pathologic mechanism of degenerative, ischemic, functional, and rheumatic MV disease. Most recently, 3D morphologic quantification has entered into clinical use to provide more accurate diagnosis of MV disease and for planning surgery and transcatheter interventions. Current limitations of this quantitative approach to MV imaging include labor-intensiveness during image segmentation and lack of a clear definition of the clinical significance of many of the morphologic parameters. This review summarizes the current development and applications of quantitative analysis of the MV morphology using RT3DE.

  2. Real-time three-dimensional echocardiographic assessment of mitral valve: Is it really superior to 2D transesophageal echocardiography?

    Science.gov (United States)

    Mukherjee, Chirojit; Tschernich, Heinz; Kaisers, Udo X; Eibel, Sarah; Seeburger, Joerg; Ender, Joerg

    2011-01-01

    Aim of our study was to investigate the feasibility of use and possible additional value of real-time 3D transesophageal echocardiography (RT-3D-TEE) compared to conventional 2D-TEE in patients undergoing elective mitral valve repair. After ethical committee approval, patients were included in this prospective study. After induction of anesthesia, a comprehensive 2D-TEE examination was performed, followed with RT-3D-TEE. The intraoperative surgical finding was used as the gold standard for segmental analysis. Only such segments which were surgically corrected either by resection or insertion of artificial chords were judged pathologic. A total of 50 patients were included in this study; usable data were available from 42 of these patients . Based on the Carpentier classification, the pathology found was type I in 2 (5%) patients, type II in 39 (93%) patients and type IIIb in 1 (2%) patient. We found that 3D imaging of complex mitral disease involving multiple segments, when compared to 2D-TEE did not show any statistically significant difference.RT-3D-TEE did not show any major advantage when compared to conventional 2D-TEE for assessing mitral valve pathology, although further study in a larger population is required to establish the validity of this study.

  3. Late Detection of Left Ventricular Dysfunction Using Two-Dimensional and Three-Dimensional Speckle-Tracking Echocardiography in Patients with History of Nonsevere Acute Myocarditis.

    Science.gov (United States)

    Caspar, Thibault; Fichot, Marie; Ohana, Mickaël; El Ghannudi, Soraya; Morel, Olivier; Ohlmann, Patrick

    2017-08-01

    Acute myocarditis (AM) often involves the left ventricular (LV) subepicardium that might be displayed by cardiac magnetic resonance even late after the acute phase. In the absence of global or regional LV dysfunction, conventional transthoracic echocardiography (TTE) does not accurately identify tissue sequelae of AM. We sought to evaluate the diagnostic value of two-dimensional (2D) and three-dimensional (3D) speckle-tracking echocardiography to identify patients with a history of AM with preserved LV ejection fraction (LVEF). Fifty patients (group 1: age, 31.4 ± 10.5 years; 76% males) with a history of cardiac magnetic resonance-confirmed diagnosis of AM (according to the Lake Louise criteria) were retrospectively identified and then (21.7 ± 23.4 months later) evaluated by complete echocardiography including 2D and 3D speckle-tracking analysis, as well as 50 age- and gender-matched healthy controls (group 2: age, 31.2 ± 9.5 years: 76% males). Patients with a history of severe clinical presentation of AM (sudden death, ventricular arrhythmia, heart failure, alteration of LVEF) were excluded. At diagnosis, peak troponin and C-reactive protein were 11.97 (interquartile range, 4.52-25.92) μg/L and 32.3 (interquartile range, 14.85-70.45) mg/L, respectively. Mean delay between acute phase and follow-up study TTE was 21.7 ± 23.4 months. LVEF was not statistically different between groups (62.1% vs 63.5%, P = .099). Two-dimensional global longitudinal strain (GLS) was lower in magnitude in group 1 (-17.8% vs -22.1%, P speckle-tracking echocardiography, even though LVEF is conserved, adding incremental information over conventional TTE. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  4. The advantages of live/real time three-dimensional transesophageal echocardiography in the assessment of tricuspid valve infective endocarditis.

    Science.gov (United States)

    Sungur, Aylin; Hsiung, Ming C; Meggo Quiroz, Luis D; Oz, Tuğba Kemaloğlu; Haj Asaad, Ayman; Joshi, Deepak; Dönmez, Cevdet; Güvenç, Tolga S; Nanda, Navin C

    2014-11-01

    Currently, tricuspid valve infective endocarditis (TVIE) is encountered in daily clinical practice more frequently due to the increasing prevalence of illicit intravenous drug use and the implantation of intracardiac devices. In this study, we compared findings from intra-operative live/real time three-dimensional transesophageal echocardiograms (3DTEE) and two-dimensional transesophageal echocardiograms (2DTEE) of 10 patients who underwent surgery for native tricuspid valve (TV) endocarditis. Unlike 2DTEE, 3DTEE allowed en face visualization of the 3 TV leaflets from both, atrial and ventricular aspects, in 9 of the 10 cases. In the remaining patient, in whom 3DTEE could not identify all 3 leaflets en face, the TV was found essentially destroyed at surgery. Using 3DTEE, the number of vegetations was accurately reported when compared with the surgical record. Furthermore, the orientation of each vegetation was the same as noted in the surgical findings. 2DTEE missed the identification of vegetations in 5 patients. The attachment site of vegetations to the TV were also not characterized by 2DTEE in 5 patients. In all 10 cases, 3DTEE characterized the vegetations more accurately with larger dimensions, including those in the azimuthal axis, and volumes. In addition, a perivalvular abscess that lead to surgical intervention was identified by 3DTEE, however, missed by 2DTEE. In conclusion, 3DTEE allows en face visualization of the TV apparatus permitting accurate description of the number and dimensions of vegetations identified by our surgical standard, which ultimately informs patients' prognosis and dictates the timing and planning for surgical intervention. Its use should be in conjunction with 2DTEE when evaluating TVIE.

  5. Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography

    Science.gov (United States)

    Demirozu, Zumrut Tuba; Kucukaksu, Deniz Suha; Arat, Nurcan

    2016-01-01

    Summary Introduction: Left ventricular assist device (LVAD) implantation is a viable therapy for patients with severe end-stage heart failure, providing effective haemodynamic support and improved quality of life. The Heart Assist 5 (Micromed Cardiovascular Inc, Houston, TX) continuous-flow LVAD has been on the market in Europe since May 2009. Methods: We evaluated nine Heart Assist 5 LVAD patients with two- and three-dimensional transthoracic echocardiographic (TTE) and transoesophageal echocardiographic (TEE) parameters between December 2011 and December 2013. The pre-operative TTE LVAD evaluations included left ventricular (LV) function and structure, quantification of right ventricular (RV) function and tricuspid regurgitation (TR), assessment of aortic and mitral regurgitation, and presence of patent foramen ovale and intra-cardiac clots. Peri-operative TEE determined the inflow cannula and septum position, and assessed the de-airing process while weaning from cardiopulmonary bypass. Post-operative serial follow-up TTE showed the surgical results of LVAD implantation, determined the overall structure and function of the LV, RV and TR, and observed the inflow and outflow cannula position. Results: Nine patients who had undergone Heart Assist 5 LVAD implantation and had been followed up for more than 30 days were included in this study. Eight patients had ischaemic cardiomyopathy and one had adriamycin-induced cardiomyopathy. Pre-implantation data: the mean age of the patients was 52 ± 13 (34–64) years, mean body surface area (BSA) was 1.8 ± 0.2 (1.6–2.0) m2, mean cardiac index (CI) was 2.04 ± 0.4 (1.5–2.6) l/min/m2, mean cardiac output (CO) was 3.7 ± 0.7 (2.6–4.2) l/min, mean ejection fraction (EF) was 23 ± 5 (18–28)%, and right ventricular fractional area contraction (RVFAC) was 43 ± 9 (35–55)%. One patient had aortic valve replacement (AVR) during the LVAD implantation, and excess current alarms and increased power were suspected to be

  6. Evaluation of left atrial volume and function in systemic sclerosis patients using speckle tracking and real-time three-dimensional echocardiography.

    Science.gov (United States)

    Ataş, Halil; Kepez, Alper; Tigen, Kürşat; Samadov, Fuad; Özen, Gülsen; Cincin, Altuğ; Sünbül, Murat; Bozbay, Mehmet; Direşkeneli, Haner; Başaran, Yelda

    2016-05-01

    The aim of the present study was to evaluate left atrial (LA) volume and functions using real-time three-dimensional echocardiography (RT3DE) and speckle tracking in systemic sclerosis (SSc) patients. The study was designed as a cross-sectional observational study. We studied 41 consecutive SSc patients (38 females, mean age: 49.5±11.6 years) and 38 healthy controls (35 females, mean age: 48.5±10.8 years). Patients with evidence or history of cardiovascular disease and patients with risk factors as hypertension, diabetes and chronic renal failure were excluded from the study. All study subjects underwent standard echocardiography; LA speckle tracking and RT3DE was performed to assess LA volume and phasic functions. Differences between numeric variables were tested using the independent sample Student's t-test or Mann-Whitney U test, where appropriate. There were no significant differences between SSC patients and controls regarding left ventricular (LV) systolic functions and two-dimensional (2-D) atrial diameters. Presence of LV diastolic dysfunction (LVDD) was evaluated and graded according to recommendations of the American Society of Echocardiography. Accordingly, LVDD was observed to be significantly more frequent in SSc patients; 16 SSc patients (39%) and 5 controls (12.8%) were observed to have LVDD (p=0.007). With regard to results obtained from RT3DE, LA maximum, minimum, and before atrial contraction volumes were significantly higher (40.5±14.6 vs. 32.6±8.9, 15.5±8.4 vs. 9.9±3.5 and 28.7±11.7 vs. 21.4±7.0 mL respectively, pspeckle tracking echocardiography, atrial peak-systolic longitudinal strain (ε), early negative strain rate (SR), late negative SR, and peak positive SR values were observed to be significantly lower in SSc patients. LA volumes were significantly increased, and LA reservoir, conduit, and contractile functions were significantly impaired in SSc patients compared with controls. LA volume and functional analyses with RT3DE and

  7. Left ventricular mechanics in repaired tetralogy of Fallot with and without pulmonary valve replacement: analysis by three-dimensional speckle tracking echocardiography.

    Directory of Open Access Journals (Sweden)

    Shu-Na Li

    Full Text Available BACKGROUND: Altered septal curvature and left ventricular (LV geometry secondary to right ventricular (RV dilation render two-dimensional assessment of LV mechanics difficult in repaired tetralogy of Fallot (TOF patients. The novel three-dimensional (3D speckle tracking echocardiography enables comprehensive evaluation of true 3D LV mechanics. METHODS AND RESULTS: Seventy-six patients aged 23.6 ± 8.3 years, 55 with isolated repair (group I and 21 with subsequent pulmonary valve replacement (group II, and 34 healthy controls were studied. Three-dimensional volume datasets were acquired for assessment of LV global and regional 3D strain, systolic dyssynchrony index (SDI, twist, twist gradient (twist/LV length, and ejection fraction. A global performance index was calculated as (global 3D strain•twist gradient/SDI. The septal curvature and LV eccentricity were determined from the mid-ventricular short-axis. Compared with controls, group I and II patients had significantly reduced LV global 3D strain, LV twist, twist gradient, septal curvature, and global performance index, and greater LV systolic and diastolic eccentricity and SDI (all p<0.05. All but the four apical LV segments in patients had reduced regional 3D strain compared with controls (all p<0.05. Septal curvature correlated with LV global 3D strain (r=0.41, p<0.001, average septal strain (r=0.38, p<0.001, twist (r=0.32, p<0.001, twist gradient (r=0.33, p<0.001, and global performance index (r=0.43, p<0.001. CONCLUSIONS: Adverse 3D LV mechanics as characterized by impaired global and regional 3D systolic strain, mechanical dyssynchrony, and reduced twist is related to reduced septal curvature in repaired TOF patients with and without pulmonary valve replacement.

  8. Left ventricular myocardial strain by three-dimensional speckle-tracking echocardiography in healthy subjects: reference values and analysis of their physiologic and technical determinants.

    Science.gov (United States)

    Muraru, Denisa; Cucchini, Umberto; Mihăilă, Sorina; Miglioranza, Marcelo Haertel; Aruta, Patrizia; Cavalli, Giacomo; Cecchetto, Antonella; Padayattil-Josè, Seena; Peluso, Diletta; Iliceto, Sabino; Badano, Luigi P

    2014-08-01

    Despite growing interest in applying three-dimensional (3D) speckle-tracking echocardiography (STE) to measure left ventricular (LV) myocardial deformation in various diseases, normative values for 3D speckle-tracking echocardiographic parameters and the effects of demographic, hemodynamic, and technical factors on these values are unknown. In 265 healthy volunteers (age range, 18-76; 57% women), longitudinal strain (3DLε), circumferential strain (3DCε), radial strain (3DRε), and area strain (3DAε) were measured by using vendor-specific (Vsp) 3D speckle-tracking echocardiographic equipment. LV strain was also measured by using Vsp two-dimensional (2D) and vendor-independent 3D speckle-tracking echocardiographic software packages, for comparison. Reference values (lower limit of normality) for Vsp 3D STE were -17% to -21% (-15%) for 3DLε, -17% to -20% (-14%) for 3DCε, -31% to -36% (-26%) for 3DAε, and 47% to 59% (38%) for 3DRε. Three-dimensional longitudinal strain decreased, whereas 3DCε increased, with aging (P < .003), with different trends in men and women. Men had lower 3DLε, 3DRε, 3DAε, and 2D longitudinal strain than women (P < .02). LV 3D strain parameters were also influenced by LV volumes and mass, image quality, and temporal resolution (P < .02). Reference values obtained by Vsp 2D STE were -20% to -23% (-18%) for 2D longitudinal strain, -20% to -24% (-17%) for 2D circumferential strain, and 39% to 54% (28%) for 2D radial strain (P < .001 vs Vsp 3D STE). Significantly different 3DCε and 3DRε values were obtained with vendor-independent versus Vsp 3D STE (P < .001). In healthy subjects, reference values of LV 3D strain parameters were significantly influenced by demographic, cardiac, and technical factors. Limits of normality of LV strain by Vsp 3D STE should not be used interchangeably with Vsp 2D STE or with Vin 3D STE software. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  9. Value of left ventricular regional ejection fraction determined by real-time three-dimensional echocardiography in diagnosis of aneurysm: compared with left ventriculography

    Institute of Scientific and Technical Information of China (English)

    LI Xiu-chang; YAN Cheng-jun; YAO Gui-hua; ZHANG Mei; LI Ji-fu; ZHANG Yun

    2009-01-01

    Background Regional ejection fraction (EF_R) measured by real-time three-dimensional echocardiography (RT-3DE)provides a novel method for quantifying left-ventricular (LV) regional systolic function. We aimed to explore the diagnostic value of regional ejection fraction (EFR) derived from RT-3DE in detecting LV aneurysms in patients with myocardial infarction. Methods Thirty-eight patients with myocardial infarction were prospectively enrolled and underwent electrocardiography (ECG), two-dimensional echocardiography (2-DE), RT-3DE and left ventriculography (LVG).Subjects with a negative EFR in at least one segment on RT-3DE were considered as having a ventricular aneurysm. We compared the sensitivity, specificity, Youden's index, and positive and negative predictive values of ECG, 2-DE and RT-3DE in determining LV aneurysm with detection by LVG.Results On LVG an LV aneurysm was diagnosed in 16 (42.1%) patients. The sensitivity and specificity were 62.5% and 86.4% for ECG, 81.2% and 95.4% for 2-DE, and 100.0% and 90.9% for RT-3DE in diagnosing LV aneurysm. Youden's indexes for ECG, 2-DE and RT-3DE were 0.49, 0.77 and 0.91, respectively. Positive and negative predictive values were 76.9% and 76.0% for ECG, 92.9% and 87.5% for 2-DE, and 88.9% and 100.0% for RT-3DE. Conclusions RT-3DE-derived EFR provides a novel, reliable index in the diagnosis of LV aneurysm and has excellent sensitivity and specificity.

  10. Percutaneous transcatheter closure of atrial septal defects: initial single-centre experience and follow-up results. Initial experience with three-dimensional echocardiography.

    Science.gov (United States)

    De Ridder, Serge; Suttorp, Maarten-Jan; Ernst, Sjef M P G; Six, Jacob A; Mannaerts, Herman F J; Kamp, Otto; Plokker, Thijs H W M; Jaarsma, Wybren

    2005-04-01

    Registry to report our single-centre experience in closing defects of the atrial septum. Between 1996 and 2001, transcatheter device closure of significant atrial septal defects was performed in 32 adults (mean age 45.1 years, range from 15 to 76 years), using different device types. Six patients had a patent foramen ovale (PFO) and 26 patients had a secundum atrial septal defect (ASD II). Defects were selected by means of two-dimensional transoesophageal echocardiography (2D TOE). For 12 defects additional three-dimensional transoesophageal echocardiography (3D TOE) was performed. Mean balloon-stretched diameter was 19.3 mm (range from 11 to 24 mm). A device was successfully placed in all PFO patients (100%) without complications at follow-up. Successful immediate device placement occurred in 24 out of 26 ASD patients. Two immediate placement failures, 1 device embolisation and 1 device non-fixation, occurred and required urgent surgery. There was 1 patient with pericardial effusion after the intervention, requiring pericardiocentesis. Three late placement failures occurred: 2 device embolisations and 1 device dislocation. Clinical success after 3 to 6 months follow-up, defined as the absence of shunt or small shunt, was achieved in all 6 PFO patients and in 21 out of 23 ASD patients (1 device embolisation, requiring surgery, occurred before follow-up was completed). Two patients with significant shunt, 1 late device dislocation and 1 late device embolisation, underwent elective surgery. For patient selection, 3D TOE proved useful in the evaluation of large and/or complex defects. Transcatheter device closure of carefully selected atrial septal defects is an alternative to surgery. Although the results are promising, surgical back-up is often needed.

  11. Methodological study on real-time three-dimensional echocardiography and its application in the diagnosis of complex congenital heart disease

    Institute of Scientific and Technical Information of China (English)

    CHEN Guo-zhen; HUANG Guo-ying; LIANG Xue-cun; MA Xiao-jing; CHEN Wei-da; TAO Zi-yu; LIN Qi-shan

    2006-01-01

    Background Real-time three-dimensional echocardiography (RT-3DE) has made revolutionized improvements of cardiac imaging during the past few years. However, there is no standard examination method for RT-3DE so far. This study aimed to establish the diagnostic method of RT-3DE and evaluate its application in the diagnosis of complex congenital heart diseases (CHD).Methods Fifty patients with complex CHD were examined by RT-3DE with modes of Live 3DE and Full Volume. A series of novel volumetric views combined with Van Praagh sequential segmental approach were introduced to reveal the pathological morphology of the hearts, which were compared with the findings of two-dimensional echocardiography (2DE), angiography and cardiac surgery.Results In 50 patients, 190 image acquisitions of Full Volume were performed at several acoustic windows including subcostal, apical and parasternal regions. Among them, 94.2% (179/190) of image acquisitions were successful. Most sectional volumetric views could be clearly displayed in 92.6% of the successful image acquisitions. However, sectional volumetric views could not be clearly displayed in 7.4%, which was mainly due to poor perspective conditions of examination location, improper instrument multi-parameter setting and insufficient information of whole heart captured in Full Volume acquisitions. As compared with surgical findings and angiography, RT-3DE made correction to the diagnoses in 2 cases including 1 with corrected transposition of the great arteries and the other with single atrium and mitral cleft. The diagnoses initially made by 2DE for these 2 patients were double outlet right ventricle with transposition of the great arteries and complete atrio-ventricular septal defect.Conclusions RT-3DE can clearly display the pathological morphology of complex CHD by a series of novel volumetric views combined with sequential segmental approach through providing more spatial informative cardiovascular structures, which provides a

  12. New Parameter Derived from Three-Dimensional Speckle-Tracking Echocardiography for the Estimation of Left Ventricular Filling Pressure in Nondilated Hearts.

    Science.gov (United States)

    Sakurai, Daisuke; Asanuma, Toshihiko; Masuda, Kasumi; Koriyama, Hikaru; Nakatani, Satoshi

    2017-05-01

    E/e' is clinically useful for the noninvasive assessment of left ventricular (LV) filling pressure. However, its use in some conditions is controversial, and angle dependence of the Doppler measurement and preload dependence of mitral e' in nondilated hearts represent major problems. The ratio of early filling rate derived from the time derivative of LV volume to early diastolic strain rate (FRe/SRe), similar to E/e', by three-dimensional (3D) speckle-tracking echocardiography has the potential to address such limitations. This study investigated whether FRe/SRe could estimate acute changes in LV filling pressure using the models of volume overload and myocardial ischemia in the nondilated heart. In 25 dogs, hemodynamic conditions were varied by acute volume overload and coronary occlusion. FRe and SRe were obtained from the same beat and automatically analyzed by the 3D speckle-tracking method, and global SRe was measured from longitudinal (L-SRe), circumferential (C-SRe), and area strain rate (A-SRe). E/e' was measured by two-dimensional echocardiography. LV pressure was derived from a micromanometer catheter and recorded simultaneously with the acquisition of the 3D images. Mitral e' and L-SRe varied by changes in preload, whereas C-SRe and A-SRe did not. C-SRe and A-SRe were more strongly correlated with the time constant of LV relaxation than mitral e' and L-SRe. FRe/C-SRe and FRe/A-SRe had relatively high correlations with LV preatrial contraction (pre-A) pressure and end-diastolic pressure, but E/e' and FRe/L-SRe did not. Receiver operating characteristics curve analysis showed that FRe/C-SRe and FRe/A-SRe had larger areas under the curve for the estimation of increased LV filling pressure. The novel parameter FRe/SRe has potential as a surrogate marker of LV filling pressure. Especially in nondilated hearts, FRe/C-SRe and FRe/A-SRe may be useful to more accurately predict LV filling pressure than E/e', although their applicability in dilated hearts

  13. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    Science.gov (United States)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; Flamm, S. D.; White, R. D.; Panza, J. A.; Thomas, J. D.

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, Pmeasurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  14. Left atrial strain assessed by three-dimensional speckle tracking echocardiography predicts atrial fibrillation recurrence after catheter ablation in patients with paroxysmal atrial fibrillation.

    Science.gov (United States)

    Mochizuki, Atsushi; Yuda, Satoshi; Fujito, Takefumi; Kawamukai, Mina; Muranaka, Atsuko; Nagahara, Daigo; Shimoshige, Shinya; Hashimoto, Akiyoshi; Miura, Tetsuji

    2017-06-01

    Several studies have shown the utility of left atrial (LA) function determined by two-dimensional or three-dimensional speckle tracking echocardiography (2D- or 3D-STE) for identifying patients with paroxysmal atrial fibrillation (AF). However, whether 3D-STE is applicable for prediction of the recurrence of AF after catheter ablation (CA) remains unknown. We examined whether any 3D-STE parameters are better than 2D-STE parameters for the prediction of AF recurrence. Forty-two patients with paroxysmal AF (58 ± 10 years old, 69% male) underwent 2D- and 3D-STE within 3 days before first-time CA. The global peak LA longitudinal, circumferential, and area strains during systole (3D-GLSs, -GCSs, and -GASs, respectively) and those just before atrial contraction (3D-GLSa, -GCSa, and -GASa, respectively) were determined by 3D-STE and standard deviations of times to peaks of regional LA strains were calculated as indices of LA dyssynchrony. In 2D-STE, global LA longitudinal strains during systole and just before atrial contraction (2D-GLSs and -GLSa) were determined. During follow-up of 441 ± 221 days, 12 patients (29%) had AF recurrence. In the univariate Cox proportional hazard analysis, age [hazard ratio (HR): 1.08, p = 0.04], 3D-GCSs (HR: 0.91, p = 0.03), and 3D-GASs (HR: 0.95, p = 0.01) were predictors of AF recurrence, though associations of recurrence with 2D-STE parameters, indices of LA synchrony, and LA volume were not significant. Multivariable analysis showed that 3D-GASs was an independent predictor of AF recurrence (HR: 0.96, p = 0.048). LA strain determined by 3D-STE is a novel and better predictor of AF recurrence after CA than that determined by 2D-STE or other known predictors.

  15. Left ventricular systolic dysfunction in asymptomatic Marfan syndrome patients is related to the severity of gene mutation: insights from the novel three dimensional speckle tracking echocardiography.

    Directory of Open Access Journals (Sweden)

    Mohamed Abd El Rahman

    Full Text Available In asymptomatic Marfan syndrome (MFS patients we evaluated the relationship between the types of fibrillin-1 (FBN1 gene mutation and possible altered left ventricular (LV function as assessed by three-dimensional speckle tracking echocardiography (3D-STE.Forty-five MFS patients (mean age 24 ± 15 years and 40 age-matched healthy controls were studied. Genetic evaluation for the FBN1 gene was carried on 32 MFS patients. Gene mutation (n = 15, 47% was classified as mild when the mutation resulted in nearly normally functioning protein, while mutations resulting in abnormally function protein were considered to be severe (n = 17, 53%. All patients and controls underwent 3D-STE for evaluation of LV function by an echocardiographer blinded to the results of the genetic testing. Compared to controls, MFS patients had significantly lower 3D-STE derived LV ejection fraction (EF, 57.43 ± 7.51 vs. 62.69 ± 4.76%, p = 0.0001, global LV longitudinal strain (LS, 14.85 ± 2.89 vs. 17.90 ± 2.01%, p = 0.0001, global LV circumferential strain (CS, 13.93 ± 2.81 vs. 16.82 ± 2.17%, p = 0.0001 and global LV area strain (AS, 25.76 ± 4.43 vs. 30.51 ± 2.61%, p = 0.0001. Apart from the global LV LS all these parameters were significantly lower in patients with severe gene mutation than in those with mild mutation (p < 0.05. In the multivariate linear regression analysis only the type of mutation had a significant influence on the 3D-STE derived LVEF (p = 0.017, global CS (p = 0.005 and global AS (p = 0.03.In asymptomatic MFS patients latent LV dysfunction can be detected using 3D STE. The LV dysfunction is mainly related to the severity of gene mutation, suggesting possible primary cardiomyopathy in MFS patients.

  16. Three-dimensional transesophageal echocardiography with agitated saline injection to differentiate between atrial septal defects and echo drop-out artifacts.

    Science.gov (United States)

    Alherbish, Aws; Shanks, Miriam; Choy, Jonathan

    2014-12-01

    The diagnosis of multiple atrial septal defects is less challenging with 3-D transesophageal echocardiography. However, the common occurrence of echo drop-out (acoustic shadow) artifacts with 3-D echocardiography can make the differentiation between a second defect and an artifact challenging. Agitated saline injection with direct visualization using 3-D echocardiography can help resolve this by allowing visualization of the bubbles crossing from true defects.

  17. Dynamic characteristic mechanism of atrial septal defect using real-time three-dimensional echocardiography and evaluation of right ventricular functions.

    Science.gov (United States)

    Sharen, Gao-Wa; Zhang, Jun; Qin, Chuan; Lv, Qing

    2017-02-01

    The dynamic characteristics of the area of the atrial septal defect (ASD) were evaluated using the technique of real-time three-dimensional echocardiography (RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane (LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group (n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method (4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the

  18. Three-dimensional mapping of mechanical activation patterns, contractile dyssynchrony and dyscoordination by two-dimensional strain echocardiography: Rationale and design of a novel software toolbox

    Directory of Open Access Journals (Sweden)

    Cramer Maarten J

    2008-05-01

    Full Text Available Abstract Background Dyssynchrony of myocardial deformation is usually described in terms of variability only (e.g. standard deviations SD's. A description in terms of the spatio-temporal distribution pattern (vector-analysis of dyssynchrony or by indices estimating its impact by expressing dyscoordination of shortening in relation to the global ventricular shortening may be preferential. Strain echocardiography by speckle tracking is a new non-invasive, albeit 2-D imaging modality to study myocardial deformation. Methods A post-processing toolbox was designed to incorporate local, speckle tracking-derived deformation data into a 36 segment 3-D model of the left ventricle. Global left ventricular shortening, standard deviations and vectors of timing of shortening were calculated. The impact of dyssynchrony was estimated by comparing the end-systolic values with either early peak values only (early shortening reserve ESR or with all peak values (virtual shortening reserve VSR, and by the internal strain fraction (ISF expressing dyscoordination as the fraction of deformation lost internally due to simultaneous shortening and stretching. These dyssynchrony parameters were compared in 8 volunteers (NL, 8 patients with Wolff-Parkinson-White syndrome (WPW, and 7 patients before (LBBB and after cardiac resynchronization therapy (CRT. Results Dyssynchrony indices merely based on variability failed to detect differences between WPW and NL and failed to demonstrate the effect of CRT. Only the 3-D vector of onset of shortening could distinguish WPW from NL, while at peak shortening and by VSR, ESR and ISF no differences were found. All tested dyssynchrony parameters yielded higher values in LBBB compared to both NL and WPW. CRT reduced the spatial divergence of shortening (both vector magnitude and direction, and improved global ventricular shortening along with reductions in ESR and dyscoordination of shortening expressed by ISF. Conclusion Incorporation

  19. Left ventricular layer function in hypertension assessed by myocardial strain rate using novel one-beat real-time three-dimensional speckle tracking echocardiography with high volume rates.

    Science.gov (United States)

    Saeki, Maki; Sato, Noriaki; Kawasaki, Masanori; Tanaka, Ryuhei; Nagaya, Maki; Watanabe, Takatomo; Ono, Koji; Noda, Toshiyuki; Zile, Michael R; Minatoguchi, Shinya

    2015-08-01

    We recently developed novel software to measure phasic strain rate (SR) using automated one-beat real-time three-dimensional speckle tracking echocardiography (3D-STE) with high volume rates. We tested the hypothesis that left ventricular (LV) systolic function and relaxation analyzed by SR with the novel 3D-STE in hypertension (HTN) with hypertrophy may be impaired in the endocardium before there is LV systolic dysfunction. We measured LV longitudinal, radial and circumferential SR in patients with HTN (n=80, 69±7 years) and age-matched normotensive controls (n= 60, 69±10 years) using 3D-STE. HTN patients were divided into four groups according to LV geometry: normal, concentric remodeling, concentric hypertrophy and eccentric hypertrophy. We measured SR during systole as an index of systolic function, SR during isovolumic relaxation (IVR) as an index of relaxation and E/e' as an index of filling pressure. Endocardial SR during systole in HTN with concentric and eccentric hypertrophy decreased compared with that in controls despite no reduction in ejection fraction or epicardial SR. Endocardial radial SR during IVR decreased even in normal geometry, and it was further reduced in concentric remodeling and hypertrophy despite no reduction in epicardial SR. LV phasic SR assessed by 3D-STE with high volume rates is a useful index to detect early decreases in LV systolic function and to predict subclinical LV layer dysfunction in patients with HTN.

  20. The mechanism of functional tricuspid regurgitation:insight from two and three-dimensional echocardiography%功能性三尖瓣反流机制的二维及三维超声心动图探索

    Institute of Scientific and Technical Information of China (English)

    孟红; 潘世伟; 胡小鹏; 逄坤静; 李建蓉; 吕秀章; 王浩; 王燕; 李澎

    2012-01-01

    Objective To explore determinants of functional tricuspid regurgitation with twodimensional (2D) and three-dimensional (3D) echocardiography,and to provide theoretical basis for surgery treatments.Methods Fifty-six subjects with left-sided valular diseases and tricuspid regurgitation underwent 2D and 3D echocardiography examinations.The tricuspid annulus diameter,the valvular tethering height and right ventricular volume and ejection fraction were measured.Results Based on the degree of tricuspid regurgitation,the patients were grouped into mild regurgitation (group 1) and moderate or more regurgitation (group 2).Comparing the two groups by t test,the tricuspid annulus diameter,the largest distance of tricuspid valvular tethering and the end-diastolic right ventricle volume had significantly enlarged in group 2 ( P <0.01 ).And the degrees of tricuspid regurgitation had good correlations with the annulus diameter,the valvular tethering,the right ventricular volume and pulmonary artery systolic pressure.Also,the 3D echocardiography revealed there were some valvular pathologies aggravating regurgitation.Conclusions The degree of functional tricuspid regurgitation is mainly determined by the annulus dilation and pulmonary hypertension.Further more,the 3D echocardiography can give us more details of the valves.%目的 应用超声心动图探索功能性三尖瓣反流的发生机制,并为手术治疗提供理论基础.方法 对56例左心瓣膜疾病合并三尖瓣反流的患者进行超声检查,测量三尖瓣瓣环直径、瓣叶闭合高度、闭合长度、心室三维容积和射血分数.结果 根据术前反流程度将56例患者分为轻度组(组1)和中度及以上组(组2),组2的瓣环直径、闭合高度、右室容积均明显大于组1( P<0.01).与反流程度重要相关的因素分别是瓣环直径、闭合高度、右室舒张末容积、肺动脉高压.术前三维超声发现合并瓣叶器质性改变会加重反流.结论 合并左心

  1. Evaluating clinic significance of mitral valvular prolapse by dynamic three-dimensional reconstruction of echocardiography%动态三维超声重建评价二尖瓣脱垂的临床意义

    Institute of Scientific and Technical Information of China (English)

    郭薇; 陈斌; 卢荔红; 俞玲; 陈德伟

    2001-01-01

    Objective The significance of dynamic three-dimensional reconstruction of echocardiography(3DRE) for mitral valvular prolapse(MVP) was evaluated.Methods Twenty patients with MVP including 13 men and 7 women (aged 13~56 years) were studied by dynamic 3DRE.The prolapsed mitral valves and their tendinous chordae were viewed. The ranges of valvular prolapse were measured.Results The surfaces of the prolapsed mitral valves showed rough and accompanied with abnormal tendinous chordae , and their bodies projected into left atrium during systole. The degree of valvular regurgitation was not related with the range of prolapse and was related with the severity of tendinous chorda injury.Conclusions The statns of prolapse could be showed objectively by dynamic 3DRE of MVP, which has obvious clinic significance.%目的评价动态三维超声重建对二尖瓣脱垂的意义。方法应用动态三维超声重建对20例二尖瓣脱垂患者进行研究,其中男性13例,女性7例,年龄15~56岁。观察脱垂的二尖瓣瓣膜与腱索,测量瓣膜脱垂的范围。结果收缩期脱垂的二尖瓣表面粗糙并向左房膨出,可伴有腱索异常。瓣膜反流的程度与脱垂范围的大小无正相关,与腱索损害的严重性有关。结论应用动态三维超声重建二尖瓣脱垂能较客观地反映脱垂的情况,有明显的临床意义。

  2. Aorto-left ventricular tunnel complicated with infective endocarditis: diagnosed by transthoracic two-dimensional and three-dimensional echocardiography%经胸二维和三维超声心动图诊断主动脉-左心室通道合并感染性心内膜炎一例

    Institute of Scientific and Technical Information of China (English)

    程蕾蕾; 赵维鹏; 潘翠珍; 丁文军; 王春生; 舒先红

    2011-01-01

    IntroductionAorto-left ventricular tunnel(ALVT)is an extrenle rare(0.001%)congenital para-valvular conmmnication between aorta and the left ventricle.It was first reported by Edwards and his colleagues in 1961[ 1].Only about 100 cases have been reported until now.We re port Out"first ease of ALVT with infective endocarditis demonstrated by two-dimensional and three-dimensional echocardiography and confirmed by surgery.%@@ IntroductionAorto-left ventricular tunnel ( ALVT) is an extreme rare (0.001% ) congenital para-valvular communication between aorta and the left ventricle.It was first reported by Edwards and his colleagues in 1961[1].Only about 100 cases have been reported until now.We report our first case of ALVT with infective endocarditis demonstrated by two-dimensional and three-dimensional echocardiography and confirmed by surgery.

  3. Three dimensional strained semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Voss, Lars; Conway, Adam; Nikolic, Rebecca J.; Leao, Cedric Rocha; Shao, Qinghui

    2016-11-08

    In one embodiment, an apparatus includes a three dimensional structure comprising a semiconductor material, and at least one thin film in contact with at least one exterior surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the three dimensional structure. In another embodiment, a method includes forming a three dimensional structure comprising a semiconductor material, and depositing at least one thin film on at least one surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the structure.

  4. Real - time three - dimensional Echocardiography Evaluation of Left Ventricular Wall Systolic Function and Exercise Echocardiography Correlation%实时三维超声心动图评价左心室下壁节段收缩功能与运动心电图的相关性研究

    Institute of Scientific and Technical Information of China (English)

    时均贵; 艾阳平; 杨海燕

    2011-01-01

    To by evaluate the left ventricular wall segments of coronary heart disease with exercise electrocardiography (ECG) test function and the correlation. Real - time three - dimensional echocardiography were measured in 30 healthy persons and 30 patients with coronary heart disease of left ventricular wall segments segments and stroke volume (regional stroke volume, r5V), end diastolic volume (rEDV), radio segment rate (rEF), all subjects were exercised treadmill test examination.60 cases obtained real - time three - dimensional images with clear endocardial order and 17 segmental volume - time curve; two groups of 17 segments rSV, rEDV, rPEF measured values were statistically significant P < 0.05), coronary heart disease in patients with segmental function and exercise stress test positive ST segment changes were highly correlated (P<0.05). The coronary heart disease patients with normal left ventricular systolic function are different, the quantitative real - time three - dimensional echocardiography evaluation of left ventricular systolic dysfunction and exercise treadmill test is positive for the detection of coronary artery disease highly correlated.%应用实时三维超声心动图技术评价冠心病患者左心室壁节段功能及其与运动心电图试验的相关性.应用实时三维超声心动图分别测量30例健康者和30冠心痛患者的左室壁节段节段每搏量(regional stroke volume,rSV)、舒张末容积(rEDV)、节段射率(rPEF),对所有受测者进行运动平板试验检查.60例受测者均获得了具有清晰内膜边界的实时三维图像和17节段容积-时间曲线;两组间17节段rSV、rEDV、rEF测值间差异有统计学意义(P<0.05),冠心病患者的节段功能与运动平板试验阳性的ST段改变高度相关(P<0.05).冠心病患者与正常人左室壁节段收缩功能存在差异,实时三维超声心动图定量评价左室壁节段收缩功能异常与运动平板试验阳性对冠心病的检测高度相关.

  5. Three-dimensional echocardiographic assessment of atrial septal defects

    Directory of Open Access Journals (Sweden)

    Charles German

    2015-01-01

    Full Text Available Echocardiography provides a useful tool in the diagnosis of many congenital heart diseases, including atrial septal defects, and aids in further delineating treatment options. Although two-dimensional echocardiography has been the standard of care in this regard, technological advancements have made three-dimensional echocardiography possible, and the images obtained in this new imaging modality are able to accurately portray the morphology, location, dimensions, and dynamic changes of defects and many other heart structures during the cardiac cycle.

  6. 术中三维超声检测二尖瓣成形前后瓣环空间构型的变化%The annulus configuration changes after mitral repair measured by three dimensional echocardiography

    Institute of Scientific and Technical Information of China (English)

    张海波; 孟旭; 郭勇; 何怡华; 韩杰; 李岩

    2014-01-01

    目的 观察术中三维超声技术检测二尖瓣成形术前后二尖瓣环空间构型的变化.方法 选择单纯二尖瓣退行性变导致重度瓣膜反流患者36例,无其他合并心脏疾病.入院后体表二维超声检测,在手术室术前经食管三维超声检测复查二尖瓣反流部位和程度,以及二尖瓣瓣环空间构型,包括二尖瓣环环径、横径、纵径、瓣环高度、前叶合后叶非平面夹角等,并初步确立手术成形方法.术后同样进行三维食管超声检测相同内容.结果 36例患者术前体表二维超声检查与术中发现完全吻合者26例(72.2%),部分吻合6例(16.7%),差距较大4例(1 1.1%).在整个心动周期中二尖瓣环持续呈“马鞍形”,于前外侧交界、后内侧交界处较低,于前瓣环、后瓣环较高.手术前后瓣环周长、瓣环横径和瓣环纵径分别为(12.4±1.4)、(7.5±0.5)cm;(34.8±2.7)、(21.8 ±1.8)mm;(34.9±3.1)、(20.4±2.1)mm.手术前后瓣环周长、瓣环横径和瓣环纵径差异均有统计学意义(均P <0.05).在收缩期,前瓣环与后瓣环之间夹角较大,在舒张期,前叶侧瓣环与后叶侧瓣环之间夹角较小.二尖瓣成形术后二尖瓣瓣环周长、横径、纵径较术前有减少.术前二尖瓣横径和纵径测量值几乎相同,在术后则纵径/横径达到93%.瓣环高度由术前(8.4±0.6) mm降低到术后的(3.0±0.1)mm,瓣环高度/横径比值由术前24%降低到14%.前后瓣环非平面夹角在成形术后由(135±14)°增加为(145±13)°,与术前比较,差异均有统计学意义(均P<0.05).结论 二尖瓣成形术后瓣环空间构型会由于人工瓣环的使用而发生变化.%Objective To investigate the configuration changes after mitral repair by three dimensional echocardiography in the operation room.Methods Serious mitral prolapse without other cardiac disorders were chosen.The routine two dimensional echocardiography was performed after admission.3 dimensional

  7. 三维斑点追踪成像评价心肌存活性的临床研究%Assessment of myocardial viability by three-dimensional speckle tracking echocardiography

    Institute of Scientific and Technical Information of China (English)

    冉红; 张平洋; 张幼祥; 张建鑫; 吴文芳; 董静; 马小五

    2014-01-01

    够作为临床提供有效区分存活与非存活心肌的新途径.%Objective To investigate the role of three-dimensional speckle tracking echocardiography (3D-STE) in providing a novel approach to assessing myocardial viability in patients with myocardial infarction (MI).Methods The subjects from the Department of Cardiology and the Department of Cardiac Surgery admitted from April 2010 through December 2012 were diagnosed as MI by electrocardiogram,myocardial enzymes and angiography.The clear imaging of angiography was selected out and collected.All patients had different degrees of segmental wall motion abnormalities,and some already had percutaneous transluminal coronary angioplasty and coronary stenting or coronary artery bypass grafting.Patients with diabetes,heart disease and severe valvular disease of heart were excluded.A total of 45 MI patients were checked with routine echocardiography,two-dimensional speckle tracking echocardiography (2D-STE) and 3D-STE.Then,radionuclide myocardial perfusion/metabolic imaging was served as a "golden standard" to distinguish the viable from nonviable myocardium in each patient within a day.In order to determine the most sensitivity and specificity threshold values of circumferential peak-systolic strain (Cs),longitudinal peak-systolic strain (Ls),radial peak-systolic strain (Rs),3D strain and area strain for viability detection from 3D-STE,the receiver operating characteristic curve was used to investigate the sensitivity and specificity of the detection of viable myocardium with strain parameters in the study.Comparisons between viable and non-viable groups were carried out with t test.Data were expressed as the mean value ± standard deviation (-x ± s).Results The ventricular wall motion abnormality by visual assessment was observed in 368 segments from 720 segments in 45 patients.Furthermore,204 segments were confirmed to be viable by radionuclide myocardial perfusion/metabolic imaging whereas the rest 164

  8. Three-dimensional photovoltaics

    Science.gov (United States)

    Myers, Bryan; Bernardi, Marco; Grossman, Jeffrey C.

    2010-03-01

    The concept of three-dimensional (3D) photovoltaics is explored computationally using a genetic algorithm to optimize the energy production in a day for arbitrarily shaped 3D solar cells confined to a given area footprint and total volume. Our simulations demonstrate that the performance of 3D photovoltaic structures scales linearly with height, leading to volumetric energy conversion, and provides power fairly evenly throughout the day. Furthermore, we show that optimal 3D shapes are not simple box-like shapes, and that design attributes such as reflectivity can be optimized in new ways using three-dimensionality.

  9. Three-dimensional metamaterials

    Science.gov (United States)

    Burckel, David Bruce [Albuquerque, NM

    2012-06-12

    A fabrication method is capable of creating canonical metamaterial structures arrayed in a three-dimensional geometry. The method uses a membrane suspended over a cavity with predefined pattern as a directional evaporation mask. Metallic and/or dielectric material can be evaporated at high vacuum through the patterned membrane to deposit resonator structures on the interior walls of the cavity, thereby providing a unit cell of micron-scale dimension. The method can produce volumetric metamaterial structures comprising layers of such unit cells of resonator structures.

  10. Three dimensional system integration

    CERN Document Server

    Papanikolaou, Antonis; Radojcic, Riko

    2010-01-01

    Three-dimensional (3D) integrated circuit (IC) stacking is the next big step in electronic system integration. It enables packing more functionality, as well as integration of heterogeneous materials, devices, and signals, in the same space (volume). This results in consumer electronics (e.g., mobile, handheld devices) which can run more powerful applications, such as full-length movies and 3D games, with longer battery life. This technology is so promising that it is expected to be a mainstream technology a few years from now, less than 10-15 years from its original conception. To achieve thi

  11. Three-Dimensional Complex Variables

    Science.gov (United States)

    Martin, E. Dale

    1988-01-01

    Report presents new theory of analytic functions of three-dimensional complex variables. While three-dimensional system subject to more limitations and more difficult to use than the two-dimensional system, useful in analysis of three-dimensional fluid flows, electrostatic potentials, and other phenomena involving harmonic functions.

  12. Real-Time Three-Dimensional Echocardiography as a Novel Approach to Quantify Left Ventricular Dyssynchrony: A Comparison Study with Phase Analysis of Gated Myocardial Perfusion Single Photon Emission Computed Tomography

    Science.gov (United States)

    Marsan, Nina Ajmone; Henneman, Maureen M.; Chen, Ji; Ypenburg, Claudia; Dibbets, Petra; Ghio, Stefano; Bleeker, Gabe B.; Stokkel, Marcel P.; van der Wall, Ernst E.; Tavazzi, Luigi; Garcia, Ernest V.; Bax, Jeroen J.

    2010-01-01

    Background Different imaging modalities have been explored for assessment of left ventricular (LV) dyssynchrony. Gated myocardial perfusion single photon emission computed tomography (GMPS) with phase analysis is a reliable technique to quantify LV dyssynchrony and predict response to cardiac resynchronization therapy. Objective Real-time 3-dimensional echocardiography (RT3DE) is a novel imaging technique that provides a LV systolic dyssynchrony index, based on regional volumetric changes as a function of time and calculated as the SD of time to minimum systolic volume of 16 standard myocardial segments expressed in percentage of cardiac cycle. The aim of this study was to compare LV dyssynchrony evaluated with GMPS with LV dyssynchrony assessed with RT3DE. Methods The study population consisted of 40 patients with heart failure who underwent both GMPS and RT3DE. Results Good correlations between LV dyssynchrony assessed with RT3DE and GMPS were demonstrated (r = 0.76 for histogram bandwidth, r = 0.80 for phase SD, P < .0001). Patients with substantial LV dyssynchrony on GMPS (defined as ≥135 degrees for histogram bandwidth and ≥43 degrees for phase SD) had significantly higher LV systolic dyssynchrony index than patients without substantial LV dyssynchrony. Conclusions The good correlations between LV dyssynchrony assessed with GMPS and with RT3DE provide further support for the use of RT3DE for reliable assessment of LV dyssynchrony. PMID:18222645

  13. Three dimensional Dirac semimetals

    Science.gov (United States)

    Zaheer, Saad

    We extend the physics of graphene to three dimensional systems by showing that Dirac points can exist on the Fermi surface of realistic materials in three dimensions. Many of the exotic electronic properties of graphene can be ascribed to the pseudorelativistic behavior of its charge carriers due to two dimensional Dirac points on the Fermi surface. We show that certain nonsymmorphic spacegroups exhibit Dirac points among the irreducible representations of the appropriate little group at high symmetry points on the surface of the Brillouin zone. We provide a list of all Brillouin zone momenta in the 230 spacegroups that can host Dirac points. We describe microscopic considerations necessary to design materials in one of the candidate spacegroups such that the Dirac point appears at the Fermi energy without any additional non-Dirac-like Fermi pockets. We use density functional theory based methods to propose six new Dirac semimetals: BiO 2 and SbO2 in the beta-cristobalite lattice (spacegroup 227), and BiCaSiO4, BiMgSiO4, BiAlInO 4, and BiZnSiO4 in the distorted spinels lattice (spacegroup 74). Additionally we derive effective Dirac Hamiltonians given group representative operators as well as tight binding models incorporating spin-orbit coupling. Finally we study the Fermi surface of zincblende (spacegroup 216) HgTe which is effectively point-like at Gamma in the Brillouin zone and exhibits accidental degeneracies along a threefold rotation axis. Whereas compressive strain gaps the band structure into a topological insulator, tensile strain shifts the accidental degeneracies away from Gamma and enlarges the Fermi surface. States on the Fermi surface exhibit nontrivial spin texture marked by winding of spins around the threefold rotation axis and by spin vortices indicating a change in the winding number. This is confirmed by microscopic calculations performed in tensile strained HgTe and Hg0.5Zn 0.5 Te as well as k.p theory. We conclude with a summary of recent

  14. Three-dimensional ultrasound scanning.

    Science.gov (United States)

    Fenster, Aaron; Parraga, Grace; Bax, Jeff

    2011-08-06

    The past two decades have witnessed developments of new imaging techniques that provide three-dimensional images about the interior of the human body in a manner never before available. Ultrasound (US) imaging is an important cost-effective technique used routinely in the management of a number of diseases. However, two-dimensional viewing of three-dimensional anatomy, using conventional two-dimensional US, limits our ability to quantify and visualize the anatomy and guide therapy, because multiple two-dimensional images must be integrated mentally. This practice is inefficient, and may lead to variability and incorrect diagnoses. Investigators and companies have addressed these limitations by developing three-dimensional US techniques. Thus, in this paper, we review the various techniques that are in current use in three-dimensional US imaging systems, with a particular emphasis placed on the geometric accuracy of the generation of three-dimensional images. The principles involved in three-dimensional US imaging are then illustrated with a diagnostic and an interventional application: (i) three-dimensional carotid US imaging for quantification and monitoring of carotid atherosclerosis and (ii) three-dimensional US-guided prostate biopsy.

  15. Evaluation of left ventricular systolic function in patients with dilated cardiomyopathy by real-time three-dimensional speckle tracking echocardiography%实时三维超声心动图斑点追踪技术评价扩张型心肌病患者左室收缩功能

    Institute of Scientific and Technical Information of China (English)

    李阳; 邓又斌; 黄润青; 孙杰; 刘琨; 汤乔颖

    2013-01-01

    目的 应用实时三维超声心动图斑点追踪技术评价扩张型心肌病(DCM)患者左室收缩功能.方法 应用实时三维超声斑点追踪技术分别测量24例DCM患者(DCM组)和19例健康成人志愿者(对照组)左室收缩期纵向、圆周向、径向以及面积应变峰值,比较两组左室心肌基底部、中间部及心尖部局部应变和总体应变的差异,并分析总体应变与左室射血分数的相关性.结果 DCM组左室心肌纵向、圆周向、径向及面积的基底部、中间部、心尖部局部应变和心肌总体应变均明显小于对照组对应节段,差异均有统计学意义(均P<0.01).左室心肌纵向、圆周向、径向以及面积总体应变均与左室射血分数有良好的相关性(r=0.873、0.862、0.885及0.894,均P<0.01).结论 实时三维超声心动图斑点追踪技术可以为DCM的诊断、疗效评估以及预后判断提供较好的检测手段,具有较大的临床价值.%Objective To evaluate the systolic function of the left ventricle in patients with dilated cardiomyopathy by real-time three-dimensional speckle tracking echocardiography.Methods The peak systolic longitudinal train,circumferential stain,radial strain and area strain of left ventricle were measued by real time three-dimensional speckle tracking echocardiography technology in 24 patients with dilated cardiomyopathy (DCM group) and 19 healthy volunteers (control group).The difference of regional myocardial strain of basal,middle,apical level and global myocardial strain were compared between the two groups.The correlation between global myocardial strain in all directions and left ventricular ejection fraction was analyzed.Results The global and each level longitudinal strain,circumferential strain,radial strain and area strain in DCM group were significantly lower than those in control group(P<0.01).The global myocardial longitudinal train,circumferential stain,radial strain and area strain were

  16. Evaluation of the structure of tricuspid valve with three dimensional echocardiography in hypoplastic right ventricle%三维超声心动图评估发育不良型三尖辦结构的价值

    Institute of Scientific and Technical Information of China (English)

    陈笋; 孙锟; 陈树宝; 张玉奇; 张志芳; 吴兰萍

    2009-01-01

    目的 应用三维超声心动图探讨右心室发育不良时三尖辦装置的结构特点.方法 28例诊断为右心室发育不良的患儿,按照三尖辦反流程度分为反流组(三尖辦反流中度及以上)与非反流组(三尖辦反流轻度及以下).18例年龄匹配的正常儿童作为对照组.应用实时三维超声心动图测定右心室容积、三尖辦辦环面积、三尖辦各辦叶的面积以及辦尖至最近乳头肌顶点的距离.测值应用体表面积(USA)进行标化.结果 右心室发育不良患儿组的右心室容积显著低于正常组,三尖辦辦环面积与右心室容积显著相关(r=0.90,P<0.0001).在三尖辦反流组,三尖辦前辦面积与辦环面积的比值较非反流组以及正常组显著增加,而后辦所占比值显著缩小.右心发育不良组各辦尖至相邻乳头肌顶点的距离显著小于正常组.反流组隔辦辦尖至相邻乳头肌距离显著小于非反流组(P=0.0023).结论 三维超声心动图可以用来评估先天性心脏病三尖辦病变.右心室发育不良患儿后辦发育不良以及隔辦腱索偏短可能是三尖辦反流的原因.%Objective To reveal the character of tricuspid valve in hypoplastic right ventricular heart syndrome (HPRVHS) using 3-dimensional echocardiography(3DE). Methods Twenty eight patients with HPRVHS were included in the study, and they were divided into two groups according the degree of tricuspid regurgitation. Eighteen normal children were included as the control. Volume of right ventricle(VRV), area of tricuspid annulus(TVA),proportion of the leaflets and the distance from tips of leaflets to the nearest papillary muscle were measured with 3DE. These data was standardized by body surface area. Results The volume of right ventricle in HPRVHS was significantly less than that in normal group. The area of tricuspid annulus was significantly correlated with volume of right ventricle(r = 0. 90, P < 0. 0001). In the tricuspid regurgitation

  17. Dynamic 3D echocardiography in virtual reality.

    NARCIS (Netherlands)

    A.E. van den Bosch (Annemien); A.H.J. Koning (Anton); F.J. Meijboom (Folkert); J.S. McGhie (Jackie); M.L. Simoons (Maarten); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2005-01-01

    textabstractBACKGROUND: This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. METHODS: Three-dimensional echocardiographic d

  18. 实时三维超声心动图容积-时间曲线评价心力衰竭患者左室舒张功能的研究%Evaluation of left ventricular diastolic function in patients with heart failure using volume-time curve by real-time three-dimensional echocardiography

    Institute of Scientific and Technical Information of China (English)

    阮坚; 潘永寿; 庾红玉; 秦蕾; 冯红兵; 皮永前

    2013-01-01

    Objective To evaluate left ventricular diastolic function in patients with heart failure (HF) using volume-time curve (VTC) by real-time three-dimensional echocardiography (RT-3DE).Methods The left ventricular peak filling rate (PFR) in 104 patients With HF and 74 Healthy volunteers using VTC by RT-3DE were measured and compared.Results PFR in patients with HF was significantly lower than the normal control subjects (P <0.01).Conclusion VTC of RT3DE can measure left ventricular PFR accurately,and evaluate left ventricular diastolic function in patients with HF.%目的 应用实时三维超声心动图(TR-3DE)容积-时间曲线(VTC)评价心力衰竭患者左室舒张功能.方法 应用TR-3DE的左室VTC测量104例心力衰竭患者和74例正常人的左室峰值充盈率(PFR),并进行比较.结果 心力衰竭患者的PFR明显小于正常对照组(P<0.001).结论 TR-3DE VTC可以准确测量左室PFR,能评价心力衰竭患者左室舒张功能状况.

  19. 实时三维超声心动图斑点追踪技术评价移植心脏左心室收缩功能%Left ventricular systolic function evaluated by real-time three-dimensional speckle tracking echocardiography in heart transplant recipients

    Institute of Scientific and Technical Information of China (English)

    刘红云; 邓又斌; 刘琨; 李阳; 汤乔颖; 魏翔; 昌盛; 卢峡

    2013-01-01

    Objective To evaluate the left ventricular systolic function in the cardiac allograft by real time three-dimensional speckle tracking echocardiography.Methods Twenty-three heart transplant recipients underwent total 57 echocardiographic studies at one,two,three months after heart transplantation.Twenty-three healthy subjects were served as controls.The three-dimensional full-volume images of left ventricle were recorded and then were analyzed using EchoPAC software.The strain curves were obtained and peak strain values of left ventricle for each segment and overall left ventricular wall were measured.Left ventricular global peak longitudinal strain (GPSL),circumferential strain (GPSC),area strain (GPSA) and radial strain (GPSR) were recorded and then statistical analyzed.Results The left ventricular ejection fraction (EF) and cardiac output (CO) in heart transplant recipients had no significant difference when compared with controls.The GPSL reduced significantly one month after surgery in heart transplant recipients than controls,but had no significant difference two months and three months after surgery with controls.The GPSC,GPSA,GPSR decreased significantly in heart transplant recipients (one,two,three months after surgery) than those in controls.Conclusions The left ventricular ejection fraction of cardiac allograft seemed "normal",but the global peak strain of left ventricle were still significantly reduced than controls.Real time three dimensional speckle tracking echocardiography can be used for an accurate assessment of left ventricular systolic function in heart transplant recipients.%目的 应用实时三维超声心动图斑点追踪技术检测移植心脏左室壁峰值收缩应变,探讨实时三维超声心动图斑点追踪技术评价移植心脏左室收缩功能的价值.方法 23例接受心脏移植患者于移植术后1月、2月、3月进行超声心动图检查,共57次.23例正常人作为对照.采集左室的三维全容积图像,应

  20. Three-dimensional echocardiography of a tricuspid valve papillary fibroelastoma

    Directory of Open Access Journals (Sweden)

    Atooshe Rohani

    2017-01-01

    Full Text Available Papillary fibroelastomas (PFE on tricuspid valve (TV are rare, accounting for fewer than 11% of all PFE. Most often they are asymptomatic, and detect on mitral valve. We report a case of a typical chest pain found to be due to papillary fibroelastoma of the tricuspid valve.

  1. 实时三维超声测量右心室容积及收缩功能的可行性研究%Feasibility of real time-three dimensional echocardiography for measuring volume and systolic function of right venticle

    Institute of Scientific and Technical Information of China (English)

    赵景宏; 乔彦; 唐红; 赵超美

    2012-01-01

    Objectives To evaluate the feasibility of real time-three dimensional echocardiography (RT-3DE) for measuring right ventricular volume and right ventricular ejection fraction (RVEF). Correlations of right ventricular volume, RVEF, right ventricular area and right ventricular fractional area change (RVFAC) measured by RT-3DE and two dimensional echocardiography were analyzed. Methods Eighty five patients with rheumatic heart disease who had undergone valvular replacement operation were enrolled in this study. Right ventricular volume and related values of right ventricle measured by RT-3DE, two dimensional echocardiography were imported to Tomtec 4D Cardio View software and manually adjusted. After endocardial boundary tracing, right ventricular end-diastolic volume (RVEDV), right ventricular end-systolic volume (RVESV), RVEF were automatically calculated by software, and right ventricular stroke volume (RVSV) was manually calculated. Correlation analysis, in retative values of right ventricle measured with RT-3DE and two dimensional echocardiography were applied. Results RVEDV,RVESV, RVSV measured with RT-3DE were significantly higher than those measrued with two dimensional echocardiography (P0.05). RVEDV,RVESV,RVSV and RVEF measured with RT-3DE and two dimensional echocardiography were positively correlated (r=0.79, 0.82, 0.68, 0.64; P<0.05). RVEDV, RVESV, RVEF measured with RT-3DE were positively correlated (r=0.76, 0.79, 0.56; P<0.05) with right ventricular end diastolic area, right ventricular end-systolic area and RVFAC measured with two dimensional echocardiography. Conclusions Right ventricular volume and RVEF measured with RT-3DE are feasible, which are positively correlated with those measured with two dimensional echocardiography. RT-3DE is better for evaluating the systolic function of right ventricle.%目的 分析实时三维超声心动图(RT-3DE)定量测量右心室容积和右心室射血分数(right ventricular ejection fraction,RVEF)的可行

  2. Creating Three-Dimensional Scenes

    Science.gov (United States)

    Krumpe, Norm

    2005-01-01

    Persistence of Vision Raytracer (POV-Ray), a free computer program for creating photo-realistic, three-dimensional scenes and a link for Mathematica users interested in generating POV-Ray files from within Mathematica, is discussed. POV-Ray has great potential in secondary mathematics classrooms and helps in strengthening students' visualization…

  3. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    Science.gov (United States)

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Evaluation of left ventricular strain by real-time three-dimensional speckle tracking echocardiography in patients with hypertension and myocardial hypertrophy%实时三维超声心动图斑点追踪技术测量高血压心肌肥厚患者收缩期左室心肌应变

    Institute of Scientific and Technical Information of China (English)

    汤乔颖; 邓又斌; 黄润青; 刘琨; 孙杰; 邓琪

    2013-01-01

    Objective To investigate left ventricular (LV) strain in patients with hypertension (HT)and myocardial hypertrophy using three-dimensional speckle tracking echocardiography.Methods Myocardial movement was analyzed in 37 primary HT patients with myocardial hypertrophy and 27 healthy volunteers.LV longitudinal,circumferential,radial and area strains were measured.The correlation between each global strain parameter and LV ejection fraction (LVEF) was analyzed.Results LV global longitudinal strain(GSL),global radial strain (GSR) and global area strain (GSA) of HT patients with myocardial hypertrophy were significantly lower than the contrast group,whereas global circumferential strain(GSC) showed no significant difference between the two groups.Longitudinal,radial and area strains were decreased in LV basal and middle levels,while decreased circumferential strain was detected only in basal level.There were significant correlations between LVEF and GSL,GSC,GSR,GSA.Conclusions Impairment of LV regional myocardial contractility can be detected by three-dimensional speckle tracking echocardiography.%目的 采用实时三维超声心动图斑点追踪技术研究原发性高血压心肌肥厚患者的收缩期左室心肌应变特点.方法 采用三维超声心动图斑点追踪技术对37例原发性高血压心肌肥厚患者及27例健康志愿者进行了室壁运动分析,测量左室纵向、圆周向、径向、面积应变,比较两组间各应变参数的差异,并分析各项整体应变参数与左室射血分数(LVEF)的相关性.结果 高血压心肌肥厚患者的左室整体纵向、径向和面积应变较正常对照组明显减低,左室整体圆周向应变与对照组间无明显差异.纵向、径向、圆周向应变在左室基底段、中段明显减低,圆周向应变减低仅见于基底段.左室整体纵向、圆周向、径向、面积应变与LVEF具有相关性.结论 实时三维超声心动图斑点追踪技术可检测到高血压心

  5. Clinical study on the left ventricular diastolic function of hypertrophy by real-time three-dimensional echocardiography and quantitative tissue velocity imaging%实时三维超声心动图和定量组织速度成像对高血压患者左心室舒张功能的研究

    Institute of Scientific and Technical Information of China (English)

    赵可辉; 刘翠红; 艾阳平

    2011-01-01

    Objective: To asscss the feasibility and accuraey of real-time three-dimensional echocardiography (RT-3DE) and quantitative tissue velocity imaging( QTVI) in quantifying left ventricular diastolic function.Methods : Twenty healthy volunteers without cardiovascular diseases and twenty patients with left ventricular hypertrophy were investigated, and the quantitative analyses were blinded to each other.To measure the left vcntricular mass (LVM) , peak filling rate (PFR) of thcm by realtime three-dimensional echocardiography (RT-3DE).To measure tissue move ahead duration midpt (TMAD Midpt) , pcak myocardial sustaincd early diastolic velocity (Ve) , peak myocardial sustained late diastolic velocity (Va) of them by quantitative tissue velocity imaging (QTVI).Results: Clear cndocardial border, real-time three-dimensional and two-dimensional images were obtained in all 40 cases.There were significant differences of left ventricular mass ( LVM) , left ventricular mass index (LVMI) , filling rate (PFR) between the two groups ( P <0.01).Mitral annulus maximum displacement (TMAD Midpt) also showed significant differences between the measured values ( P <0.01).Scpta2, lateral basal segment of left ventricular carly diastolic and late diastolic peak velocity (Ve, Va) and the ratio (Ve / Va) showed significant difference between measured values ( P <0.01).Left ventricular filling rate (PFR) , left ventricular septal and latcral basal diastolic peak early and late diastolic velocity ratio (Ve / Va) , the largest midpoint of mitral annular displacemcnt (TMAD Midpt) had a high correlation with the carly diastolic and late diastolic velocity ratio ( E/A) on traditional two-dimensional echocardiography test, the correlation coefficients were 0.962, 0.961, 0.434.Conclusion: Diastolic function left ventricular in healthy adult and patients with left ventricular hypertrophy has heterogeneity.RT-3DE and QTVI provides a new method in assessing the left ventricular function.%目

  6. 经食管实时三维超声在主动脉瓣狭窄患者瓣环径定量中的应用%Application of the real-time three-dimensional transesophageal echocardiography in the quantification of aortic anuulus diameter in patients with aortic stenosis

    Institute of Scientific and Technical Information of China (English)

    孔令秋; 唐红; 魏薪; 康彧; 任奔; 宋海波

    2013-01-01

    目的 探讨经食管实时三维超声心动图(RT-3D TEE)在主动脉瓣狭窄患者主动脉瓣环径定量分析中的应用价值.方法 65例因重度主动脉瓣狭窄行外科手术者,术中采集主动脉根部RT-3D TEE图像,运用瓣环定量软件重建主动脉瓣环,生成瓣环参数并计算基于此的瓣环径(3D-A-AAD、3D-C-AAD),并将其与外科测瓣器测值(IO-AAD)进行一致性分析.结果 基于三维瓣环参数的主动脉瓣环径3D-A-AAD和3D-C-AAD分别为(22.4±2.1)mm、(23.4±1.9)mm.二者测值与术IO-AAD[(23.4±2.2)mm]相比,差异均无统计学意义(P<0.05),与3D-A-AAD相比,3D-C-AAD与IO-AAD的一致性较好.结论 RT-3D TEE及瓣环定量分析软件不仅能重建主动脉瓣环三维形态,还可用作瓣环径定量分析工具.%Objective To investigate the application of real-time three-dimensional transesophageal echocardiography (RT-3D TEE) in quantification of the aortic anuulus diameter in patients with severe aortic stenosis.Methods RT-3D TEE image of aortic root was get perioperatively in 65 patients with sever aortic valve stenosis during the surgery procedure.The aortic annulus was reconstructed in the quantitative analysis software to generate the parameters of 3-dimensional area based aortic anuulus diameter(3D-AAAD) and 3-dimensional circumference based aortic anuulus diameter(3D-C-AAD).The parameters was compared with intraoperative aortic anuulus diameter(IO-AAD),which was get by the standard cylindrical valve sizer.Results The three dimensional form of the aortic annulus was related to the number of the valves.The value of 3D-C AAD and 3D-A-AAD were (22.4 ± 2.1) mm,(23.4 ± 1.9) mm,no significant difference could be detected between them and the IO-AAD (P < 0.05).The 3D-C-AAD had a better agreements with IO-AAD than 3D-A-AAD.Conclusions RT-3D TEE can reconstruct the three dimensional sharp of aortic anuulus,and can be used as quantitative tools to calculate its diameter.

  7. Facial three-dimensional morphometry.

    Science.gov (United States)

    Ferrario, V F; Sforza, C; Poggio, C E; Serrao, G

    1996-01-01

    Three-dimensional facial morphometry was investigated in a sample of 40 men and 40 women, with a new noninvasive computerized method. Subjects ranged in age between 19 and 32 years, had sound dentitions, and no craniocervical disorders. For each subject, 16 cutaneous facial landmarks were automatically collected by a system consisting of two infrared camera coupled device (CCD) cameras, real time hardware for the recognition of markers, and software for the three-dimensional reconstruction of landmarks' x, y, z coordinates. From these landmarks, 15 linear and 10 angular measurements, and four linear distance ratios were computed and averaged for sex. For all angular values, both samples showed a narrow variability and no significant gender differences were demonstrated. Conversely, all the linear measurements were significantly higher in men than in women. The highest intersample variability was observed for the measurements of facial height (prevalent vertical dimension), and the lowest for the measurements of facial depth (prevalent horizontal dimension). The proportions of upper and lower face height relative to the anterior face height showed a significant sex difference. Mean values were in good agreement with literature data collected with traditional methods. The described method allowed the direct and noninvasive calculation of three-dimensional linear and angular measurements that would be usefully applied in clinics as a supplement to the classic x-ray cephalometric analyses.

  8. Quasicrystalline three-dimensional foams

    Science.gov (United States)

    Cox, S. J.; Graner, F.; Mosseri, R.; Sadoc, J.-F.

    2017-03-01

    We present a numerical study of quasiperiodic foams, in which the bubbles are generated as duals of quasiperiodic Frank–Kasper phases. These foams are investigated as potential candidates to the celebrated Kelvin problem for the partition of three-dimensional space with equal volume bubbles and minimal surface area. Interestingly, one of the computed structures falls close to (but still slightly above) the best known Weaire–Phelan periodic candidate. In addition we find a correlation between the normalized bubble surface area and the root mean squared deviation of the number of faces, giving an additional clue to understanding the main geometrical ingredients driving the Kelvin problem.

  9. Quantitative assessment of left ventricular function in patients with percutaneous coronary intervention by real-time three-dimensional echocardiography%实时三维超声心动图定量评价冠状动脉介入治疗术后左心功能的研究

    Institute of Scientific and Technical Information of China (English)

    齐清华; 张连仲; 高传玉

    2011-01-01

    目的:探讨实时三维超声心动图(RT-3DE)在评价经皮冠状动脉介入治疗(PCI)术前后患者左心室功能的价值.方法:选择成功接受PCI治疗的患者30例作为冠心病组,无冠状动脉狭窄者20例作为正常对照组,应用RT-3DE对冠心病组于术前3-5天、术后3天及术后1个月测量左室舒张末容积(EDV)、左室收缩末容积(ESV)、左心室射血分数(EF)、峰值射血率(PER)、峰值充盈率(PFR)、达到最小收缩容积时间的标准差(Tmsv16-SD)及最大差值(Tmsv16-Dif),对照组与冠心病组的测值进行比较,PCI术前后测值进行比较.结果:病例组术前EDV、ESV、Tmsv16-SD、Tmsv16-Dif显著增加(P<0.01),EF、PER、PFR显著减小(P<0.01);与术前比较,患者术后EDV、ESV、Tmsv16-SD、Tmsv16-Dif显著减小,整体EF、PER、PFR显著增加(P<0.01).结论:冠心病患者的左心室功能可发生重构,PCI能逆转其重构,RT-3DE可准确评价PCI术后患者左心室功能的逆转.%Objective: To assess the value of real-time three-dimensional echocardiography (RT-3DE) in the evaluation of left ventricular function in patients with coronary artery disease(CAD) after percutaneous coronary intervention(PCI).Methods:RT-3DE was performed in 30 patients who accepted PCI treatment successfully and 20 normal subjects who had no coronary artery stenosis.RT-3DE was performed and three-dimensional image data were analyzed.Seties of left ventricular parameters were measured in 3~5 days pre-, 3 days post- and 1 month post-operation.Left ventricular end-diastolic volume(EDV), endsystolic volume(ESV), ejection fraction(EF), the peak ejection rate(PER), peak filling rate(PFR), the time to the point with minimal systolic volume (Tmsv) in 16 segments standard deviation and the maximal difference of time (Tmsvl6-SD, Tmsvl6-Dif).These parameters were respectively compared.Results: Compared with normal subjects, EDV, ESV, Tmsvl6-SD, Tmsvl6-Dif were significantly increased(P<0.0l).EF, PER and

  10. 实时三维经食管超声心动图在二尖瓣脱垂手术中的应用价值%Clinical values of intraoperative real-time three-dimensional transesophageal echocardiography for surgery in patients with mitral valve prolapse

    Institute of Scientific and Technical Information of China (English)

    许立龙; 赵博文; 李世岩; 钱希明; 何启才; 毛彦恺; 余婵; 潘美

    2012-01-01

    Objective To investigate the value of the intraoperative real-time three-dimensional transesophageal echocardiography (RT 3D-TEE) in therapeutic application of surgery for the mitral valve prolapse.Methods Thirty-five patients underwent surgical treatment were diagnosed as mitral valve prolapse by 2-dimensional transthoracic echocardiography (2D-TTE),with or without ruptured chordae tendineae.RT 3D-TEE was performed for assessing the segment of prolapse and its complications before cardiopulmonary bypass and after heart resuscitation respectively.The echocardiographic results were compared with the surgical findings.Results The accuracy of RT 3D-TEE to identify segments with prolapse was significantly higher than that of 2D-TTE (91.4% vs 82.9%,P =0.003).RT 3D-TEE was more accurate than 2D-TTE for identifying ruptured chordae tendineae,vegetation and thrombus since higher sensitivity,specificity and Youden index.Among all 35 patients,valvuloplasty was performed in 28 cases,whereas,only 7 cases underwent replacement of prosthetic valves.Three patients were benefited by accurate evaluation of therapeutic effect using RT 3D-TEE in time.Conclusions Intraoperative RT 3D-TEE can be used to provide “ surgical view”,acquired adequate valuable information of mitral valve,and more reliable functional and anatomical assessment of the mitral valve components and its geometry.Suitable surgical intervention can be designed for improving outcomes of patients.%目的 探讨术中实时三维经食管超声心动图(RT 3D-TEE)在二尖瓣脱垂患者外科手术治疗中的应用价值.方法 选择经胸超声心动图(2D-TTE)诊断为二尖瓣脱垂(伴或不伴腱索断裂),并进行外科手术治疗的35例患者,于麻醉后体外循环之前行RT 3D-TEE检查,将2D-TTE及RT 3D-TEE结果与术中所见进行比较.并在手术完成心脏复跳后即刻再次进行检查,评价手术疗效.结果 与手术医师术中发现相比较,术中RT 3D-TEE判断

  11. Real-time three-dimensional echocardiography evaluation of left ventricular wall systolic function and correlation with exercise electrocardiography%实时三维超声心动图评价冠心病患者左心室壁节段收缩功能与运动心电图的相关性研究

    Institute of Scientific and Technical Information of China (English)

    艾阳平; 杨海燕

    2013-01-01

    Objective To evaluate the function of segments of left ventricular wall in patients with coronary heart disease and its correlation with exercise electrocardiography by real—time three—dimensional ecbocardiography (RT — 3DE). Methods Thirty healthy persons and 30 patients with coronary heart disease were enrolled in this study. The stroke volume (regional stroke volume, rSV) .end diastolic volume (rEDV), regional radio segment rate ( rEF) of 17 segments of left ventricular wall were measured by real-time three —dimensional echocardiography. And all subjects underwent treadmill exercise test. Results The real-time three-dimensional images with clear endocardia! border and 3.7 scgmental volume—time curves were obtained in both groups. Significant differences were found in rSV,rEDV,rPEF values of 17 segments between the two groups (P<0.05). The segmental function in patients with coronary heart disease and ST segment changes from positive exercise stress test were highly correlated(P<0. 05). Conclusion There is significant difference in left ventricular systolic function between patients with coronary heart disease and health control. The quantitative real —time three —dimensional echocardiography for the evaluation of left ventricular systolic dysfunction and treadmill exercise test in the detection of coronary artery disease are highly correlated,%目的 应用实时三维超声心动图(RT-3DE)评价冠心病患者左心室壁节段功能及其与运动心电图的相关性.方法 冠心病组患者30 例,30 例健康者为对照组,RT-3DE 分别测量其左室壁17 节段的节段每搏量(rSV)、舒张末容积(rEDV)及节段射血率(rPEF),所有受检者进行平板运动试验.结果 两组均获得具有清晰内膜边界的实时三维图像和17 节段容积-时间曲线;两组间17 节段rSV、rEDV、rPEF 测值间差异有统计学意义(P﹤0.05);冠心病患者的节段功能与平板运动试验阳性的ST 段改变高度相关(P﹤0

  12. 常规及实时三维超声心动图在成人Ebstein畸形诊断中的应用价值%Diagnosis of Ebstein anomaly with conventional and transthoracic real-time three-dimensional echocardiography

    Institute of Scientific and Technical Information of China (English)

    江勇; 王浩; 陆敏杰; 万琳媛; 王吴刚; 张茗卉; 吴伟春; 孙欣

    2015-01-01

    ObjectiveTo explore the value of conventional echocardiography and transthoracic real-time three-dimensional echocardiography (RT3DE) in diagnosis of Ebstein anomaly.MethodsWe investigated the morphology and function of right ventricle (RV) as well as the structure, morphology and regurgitation of tricuspid valve in 61 adult patients with Ebstein anomaly before surgery by using conventional echocardiography and transthoracic RT3DE. Twenty normal adults were enrolled as control group. ResultsThe surface of the tricuspid leaflets, the morphology of the tricuspid annulus as well as the three-dimensional structure of the tricuspid valve were displayed stereoscopically by RT3DE. Complete RV volume data could be acquired in 32 patients of Ebstein anomaly. The apex or part of RV could not be contained in the remaining 29 patients. Thirty-four (55.7%) patients with Ebstein anomaly had severe tricuspid regurgitation, 16 (26.2%) patients had moderate to severe regurgitation, and 11 (18.1%) patients had moderate regurgitation. Compared with the normal adults, patients of Ebstein anomaly showed higher RV end-diastolic volume (EDV), end-systolic volume (ESV), end-diastolic volume index (EDVI), end-systolic volume index (ESVI), stroke volume (SV), RV anterior-posterior diameter (RV), tricuspid valve annular transverse diameter (TV-R), and lower RV ejection fraction(EF) [(273.5±77.7) mlvs (74.3±15.9) ml, (187.1±96.8) mlvs (31.1±9.2) ml, (177.4±53.6) ml/m2vs (43.4±8.2) ml/m2, (121.7±65.5) ml/m2vs (18.4±5.1) ml/m2, (95.9±20.2) ml vs (43.6±8.8) ml, (48.1±13.3) ml/m2vs (19.0±1.9) ml/m2, (56.4±8.9) ml/m2vs (28.5±4.3) ml/m2, (38.3±12.8) %vs (59.3±5.1) %, allP<0.05). The tricuspid regurgitant orifice flow cross-sectional area (EROA) were correlated positively with RV anterior-posterior diameter (r=0.691), ratio of RV and LV anterior-posterior diameter (RV/LV) (r=0.6471).ConclusionTransthoracic RT3DE is a feasible method in addition to conventional two

  13. Three-dimensional display technologies.

    Science.gov (United States)

    Geng, Jason

    2013-01-01

    The physical world around us is three-dimensional (3D), yet traditional display devices can show only two-dimensional (2D) flat images that lack depth (i.e., the third dimension) information. This fundamental restriction greatly limits our ability to perceive and to understand the complexity of real-world objects. Nearly 50% of the capability of the human brain is devoted to processing visual information [Human Anatomy & Physiology (Pearson, 2012)]. Flat images and 2D displays do not harness the brain's power effectively. With rapid advances in the electronics, optics, laser, and photonics fields, true 3D display technologies are making their way into the marketplace. 3D movies, 3D TV, 3D mobile devices, and 3D games have increasingly demanded true 3D display with no eyeglasses (autostereoscopic). Therefore, it would be very beneficial to readers of this journal to have a systematic review of state-of-the-art 3D display technologies.

  14. Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking

    OpenAIRE

    Arias-Godínez,José Antonio; Guadalajara-Boo,José Fernando; Patel, Ayan R; Pandian, Natesa G.

    2011-01-01

    One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to carry out and with superior accuracy and reproducibility. However, regional myocardial function is mo...

  15. Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking

    OpenAIRE

    Arias-Godínez,José Antonio; Guadalajara-Boo,José Fernando; Patel,Ayan R.; Pandian, Natesa G

    2011-01-01

    One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to carry out and with superior accuracy and reproducibility. However, regional myocardial function is mo...

  16. Comparision between thecolor-changed on bull′s-eye plot and global strain of three-dimensional speckle tracking echocardiography for diagnosis coronary artery stenosis%三维斑点追踪牛眼图颜色改变与整体应变诊断冠脉多支病变临床应用价值的研究

    Institute of Scientific and Technical Information of China (English)

    龚晓萍; 李艳红; 穆玉明; 吴治胜

    2016-01-01

    目的:探讨三维斑点追踪(3-dimensional speckle tracking echocardiography,3D-STE )牛眼图颜色改变和整体应变诊断冠脉多支病变的超声心动图特点及其临床应用价值。方法根据冠脉造影的结果,将117例受检者分为冠脉多支组(45例)、单支组(32例)、对照组(40例)。所有受检者行常规经胸二维和三维超声心动图检查,应用3D-STE技术自动生成17节段牛眼图:长轴(LS)、周向(CS)、面积(AS)及径向(RS)应变牛眼图。计算牛眼图中颜色改变节段数,记录左室整体长轴(GLS)、周向(GCS)、面积(GAS)和径向应变(GRS),分析其诊断冠脉多支病变临床应用价值。结果与对照组相比,多支组及单支组牛眼图颜色改变节段数4个参数增多,差异有统计学意义(P <0.05),且多支组增多更明显;多支组整体应变4个参数低于对照组,差异有统计学意义(P <0.05)。与单支组比较,多支组牛眼图颜色改变节段数4个参数增多,但仅周向和面积应变差异有统计学意义(P <0.05)。多支组整体应变4个参数均减低,但差异无统计学意义。ROC分析显示三维斑点追踪牛眼图面积应变诊断冠脉多支病变的灵敏度(86.7%)和特异度(87.5%)最高;整体长轴应变的灵敏度最高(68.9%),整体面积应变的特异度最高(77.5%)。结论三维斑点追踪牛眼图颜色改变节段数与整体应变均能较好地评价冠脉多支病变,而牛眼图颜色改变节段数灵敏度和特异度更高。%Objective To analyze the color-changed on bull′s-eye plot and global strain of three-dimensional speckle tracking echocardiography and to assess the value in the detection n of coronary stenosis.Methods A total of 1 1 7 consecutive patients were enrolled and divided into the following three groups according to the coronary angiography (CAG

  17. Application of real-time three-dimensional transesphaogeal echocardiography in quantitation of tricuspid valve annulus diameter%经食管实时三维超声心动图对三尖瓣环径测量位点的研究

    Institute of Scientific and Technical Information of China (English)

    孔令秋; 康彧; 唐红; 张尔永; 肖锡俊; 郭应强; 宋海波

    2013-01-01

    Objective To verify the feasibility and accuracy in the measurement of tricuspid valve annulus diameter(TVD) in the right ventricular outflow tract view.Methods Seventy five patients under the valve replacement surgery for the left heart valve lesions were divided into mild,moderate and severe group according to the severity of the regurgitation.The TVD was get on the apical four-chamber heart viewpreoperatively by transthoracic echocardiography(TTE),noted as TTE-TVD,meanwhile it was also get by the transesophageal echocardiography on the four-chamber view (TEE-TVD),right ventricular inflow (RVIT-TVD) and outflow tract view(RVOT-TVD).The changes of tricuspid regurgitation severtity was observed preoperatively.And the morphology of tricuspid annulus were observed using both real-time three dimensional transesophageal echocardiography (RT-3D TEE) and the quantitative software.Results Comparison in the groups:no statistically significant difference (P >0.05) was found between TTE-TVD,TEE-TVD and RVIT-TVD;while the RVOT-TVD was significant greater than that in the same group from other views (P < 0.05).Comparison between the groups:no significant difference was found between mild and moderate regurgitation group on the same view.There was a significant difference of the TVD between the severe regurgitation group and the former two groups on each view(P <0.05).The severity of tricuspid regurgitation in intraoperative anesthesia was reduced.The "saddle" tricuspid ring evolved into the narrow planar structure on the RT-3D TEE.For the expansion of the annulus,it departure from the tricuspid septal leaflet.Conclusions TVD measured on the right ventricular outflow tract view reflect the maximum expansion of the tricuspid valve annulus diameter,and can effectively guide the decision-making choices of the surgeon.%目的 探讨在右室流出道切面测量三尖瓣环径(TVD)的可行性与准确性.方法 75例因左心瓣膜损害而行瓣膜置换术患者,根据

  18. Recent advances in echocardiography for valvular heart disease.

    Science.gov (United States)

    Hahn, Rebecca

    2015-01-01

    Echocardiography is the imaging modality of choice for the assessment of patients with valvular heart disease. Echocardiographic advancements may have particular impact on the assessment and management of patients with valvular heart disease. This review will summarize the current literature on advancements, such as three-dimensional echocardiography, strain imaging, intracardiac echocardiography, and fusion imaging, in this patient population.

  19. True three-dimensional camera

    Science.gov (United States)

    Kornreich, Philipp; Farell, Bart

    2013-01-01

    An imager that can measure the distance from each pixel to the point on the object that is in focus at the pixel is described. This is accomplished by short photo-conducting lightguides at each pixel. In the eye the rods and cones are the fiber-like lightguides. The device uses ambient light that is only coherent in spherical shell-shaped light packets of thickness of one coherence length. Modern semiconductor technology permits the construction of lightguides shorter than a coherence length of ambient light. Each of the frequency components of the broad band light arriving at a pixel has a phase proportional to the distance from an object point to its image pixel. Light frequency components in the packet arriving at a pixel through a convex lens add constructively only if the light comes from the object point in focus at this pixel. The light in packets from all other object points cancels. Thus the pixel receives light from one object point only. The lightguide has contacts along its length. The lightguide charge carriers are generated by the light patterns. These light patterns, and thus the photocurrent, shift in response to the phase of the input signal. Thus, the photocurrent is a function of the distance from the pixel to its object point. Applications include autonomous vehicle navigation and robotic vision. Another application is a crude teleportation system consisting of a camera and a three-dimensional printer at a remote location.

  20. Three-dimensional IC trends

    Energy Technology Data Exchange (ETDEWEB)

    Akasaka, Y.

    1986-12-01

    VLSI will be reaching to the limit of minimization in the 1990s, and after that, further increase of packing density or functions might depend on the vertical integration technology. Three-dimensional (3-D) integration is expected to provide several advantages, such as 1) parallel processing, 2) high-speed operation, 3) high packing density, and 4) multifunctional operation. Basic technologies of 3-D IC are to fabricate SOI layers and to stack them monolithically. Crystallinity of the recrystallized layer in SOI has increasingly become better, and very recently crystal-axis controlled, defect-free single-crystal areas has been obtained in chip size level by laser recystallization technology. Some basic functional models showing the concept or image of a future 3-D IC were fabricated in two or three stacked active layers. Some other proposals of subsystems in the application of 3-D structure, and the technical issues for realizing practical 3-D IC, i.e., the technology for fabricating high-quality SOI crystal on complicated surface topology, crosstalk of the signals between the stacked layers, total power consumption and cooling of the chip, are also discussed in this paper.

  1. Three-dimensional colloidal lithography.

    Science.gov (United States)

    Nagai, Hironori; Poteet, Austen; Zhang, Xu A; Chang, Chih-Hao

    2017-03-24

    Light interactions with colloidal particles can generate a variety of complex three-dimensional (3D) intensity patterns, which can be utilized for nanolithography. The study of particle-light interactions can add more types of intensity patterns by manipulating key factors. Here we investigate a novel 3D nanolithography technique using colloidal particles under two-beam coherent illuminations. The fabricated 3D nanostructures are hollow, nested within periodic structures, and possess multiple chamber geometry. The effects of incident angles and particle size on the fabricated nanostructures were examined. The relative phase shift between particle position and interference pattern is identified as another significant parameter influencing the resultant nanostructures. A numerical model has been developed to show the evolution of nanostructure geometry with phase shifts, and experimental studies confirm the simulation results. Through the introduction of single colloidal particles, the fabrication capability of Lloyd's mirror interference can now be extended to fabrication of 3D nanostructure with complex shell geometry. The fabricated hollow nanostructures with grating background could find potential applications in the area of photonics, drug delivery, and nanofluidics.

  2. Three dimensional magnetic abacus memory

    Science.gov (United States)

    Zhang, Shilei; Zhang, Jingyan; Baker, Alexander; Wang, Shouguo; Yu, Guanghua; Hesjedal, Thorsten

    2015-03-01

    Stacking nonvolatile memory cells into a three-dimensional matrix represents a powerful solution for the future of magnetic memory. However, it is technologically challenging to access the individual data in the storage medium if large numbers of bits are stacked on top of each other. Here we introduce a new type of multilevel, nonvolatile magnetic memory concept, the magnetic abacus. Instead of storing information in individual magnetic layers, thereby having to read out each magnetic layer separately, the magnetic abacus adopts a new encoding scheme which envisages a classical abacus with the beads operated by electron spins. It is inspired by the idea of second quantization, dealing with the memory state of the entire stack simultaneously. Direct read operations are implemented by measuring the artificially engineered `quantized' Hall voltage, representing a count of the spin-up and spin-down layers in the stack. This concept of `second quantization of memory' realizes the 3D memory architecture with superior reading and operation efficiency, thus is a promising approach for future nonvolatile magnetic random access memory.

  3. Three-dimensional colloidal lithography

    Science.gov (United States)

    Nagai, Hironori; Poteet, Austen; Zhang, Xu A.; Chang, Chih-Hao

    2017-03-01

    Light interactions with colloidal particles can generate a variety of complex three-dimensional (3D) intensity patterns, which can be utilized for nanolithography. The study of particle–light interactions can add more types of intensity patterns by manipulating key factors. Here we investigate a novel 3D nanolithography technique using colloidal particles under two-beam coherent illuminations. The fabricated 3D nanostructures are hollow, nested within periodic structures, and possess multiple chamber geometry. The effects of incident angles and particle size on the fabricated nanostructures were examined. The relative phase shift between particle position and interference pattern is identified as another significant parameter influencing the resultant nanostructures. A numerical model has been developed to show the evolution of nanostructure geometry with phase shifts, and experimental studies confirm the simulation results. Through the introduction of single colloidal particles, the fabrication capability of Lloyd’s mirror interference can now be extended to fabrication of 3D nanostructure with complex shell geometry. The fabricated hollow nanostructures with grating background could find potential applications in the area of photonics, drug delivery, and nanofluidics.

  4. Change of left ventricular function in peripartum cardiomyopathy after medicine treatment using real-time three-dimensional echocardiography%实时三维超声评价围产期心肌病治疗前后左心室收缩功能的变化

    Institute of Scientific and Technical Information of China (English)

    侯琳琳; 高潮; 史学功; 王邦宁

    2012-01-01

    目的 应用实时三维超声心动图(RT-3DE)对围产期心肌病(peripartum cardiomyopathy,PPCM)患者内科治疗的效果进行评价分析.方法 所有患者均在首次入院后1周内、治疗后3个月,治疗后12个月分别行RT-3DE检查,测量左心室舒张末期容积(LVEDV)、左心室收缩末期容积(LVESV),左心室射血分数(LVEF).结果 治疗后3个月随访LVEDV、LVESV较入院后1周内明显减少,LVEF较入院后1周内明显增加,(123.05±21.77)ml,(79.45±30.97)ml,(45.93±4.28)%vs(141.05±33.20)ml,(97.53±38.57)ml,(37.85±6.28)%.治疗后12个月上述指标较入院后1周内效果亦有明显改善.但较治疗后3个月变化差异无统计学意义.结论 RT-3DE可以准确评估左心室功能.目前药物治疗对于改善PPCM患者心脏形态功能作用有限.%Objective Real-time three-dimensional echocardiography(RT-3DE) was used to evaluate the effect of medicine treatment on peripartum cardiomyopathy(PPCM ). Methods All patients individually underwent RT-3DE soon after one week in first admission in hospital, treatment for three months later and twelve months later. Left ventricular end-diastolic volume (LVEDV),left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF) were measured. Results In three months' follow-up, LVEDV and LVESV decreased significantly compared with those measured soon after one week in first admission in hospital, meanwhile LVEF increased significantly,(123. 05 + 21.77) ml, (79. 45 + 30. 97) ml, (45. 93 + 4. 28)% vs (141.05 + 33.20) ml, (97. 53 + 38. 57) ml, (37. 85 + 6. 28) %. In twelve months' follow-up, all the indexes improved significantly compared with those measured soon after one week in first admission in hospital, however all the indexes did not improve significantly compared with those measured three months later. Conclusion RT-3DE was used to evaluate the left ventricular volume and systolic function accurately. The effect of medicine treatment on

  5. Reverse remodeling of left ventricular evaluated by real-time three-dimensional echocardiography in patients with coronary artery bypass graft%实时三维超声心动图评价冠状动脉旁路移植术后患者左心室重构的逆转

    Institute of Scientific and Technical Information of China (English)

    边晓琳; 王雁; 张连仲; 刘琳

    2014-01-01

    Objective To evaluate the clinical application value of reverse remodeling of left ventricular function and synchronism on coronary artery disease( CAD)patients after coronary artery by-pass graft(CABG)using real-time three-dimensional echocardiography(RT-3DE). Methods Left ven-tricular end-diastolic volume( LVEDV),16-segments synchronized indices,peak ejection rate( PER), peak early filling rate(PFR)were measured by RT-3DE in 31 patients with three-vessels of CAD pre-op-eration and post-operation 1 month after CABG. Thirty normal people as control group without coronary stenosis,which were verified by coronary angiography. Results There was significant difference between patients group and control group,LVEDV,Tmsv16-SD and Tmsv16-Dif were significantly increased( P﹤0. 01)in patients group,left ventricular ejection fraction( LVEF),PER and PFR were significantly de-creased(P﹤0. 01)in patients group. There was significant difference between pre-operation and post-op-eration 1 month,LVEDV,Tmsv16-SD and Tmsv16-Dif were significantly decreased in post-operation group,LVEF,PER and PFR were significantly increased( P﹤0. 01 )in post-operation group. Conclu-sions Left ventricular remodeling is induced by three-vessels lesion in patients with CAD. CABG can reverse left ventricular remodeling. The left ventricular reverse remodeling can be evaluated by RT3DE in CAD after CABG.%目的:探讨实时三维超声心动图技术评价冠心病患者冠状动脉旁路移植术后左室收缩功能和同步性逆转的应用价值。方法经选择性冠状动脉造影证实为三支冠状动脉病变的31例冠心病患者,应用实时三维超声心动图于术前及术后1个月测量左心室舒张末期容积(LVEDV)、峰值射血率(PER)、峰值充盈率(PFR)、16节段达峰时间的标准差(Tmsv16-SD)和最大时间差(Tmsv16-Dif),与30例冠状动脉正常的受检者对比分析。结果与对照组相比,病例组LVEDV、Tmsv16-SD

  6. Quantitative evaluation of left ventricular global systolic function in patients with myocardial infarction by three-dimensional speckle tracking echocardiography%超声三维斑点追踪成像评价心肌梗死患者左心室整体收缩功能的研究

    Institute of Scientific and Technical Information of China (English)

    王丁; 邓又斌; 黄润青

    2012-01-01

    Objective To evaluate the value and characteristics of left ventricular global systolic strain and its relation to the left ventricular global systolic function in patients with myocardial infarction(MI) by three-dimensional speckle tracking echocardiography (3D-STI).Methods In 24 patient subjects and 20 control subjects,the myocardial motion was tracking by 3D-STI,left ventricular ejection fraction(LVEF),and global longitudinal peak systolic strain(LVGLS),global circular peak systolic strain(LVGCS),global radial peak systolic strain(LVGRS),global area peak systolic strain(LVGAS) were measured.The values were compared between the two groups,the correlations between LVEF and LVGLS,LVGCS,LVGRS,LVGAS were analyzed respectively.Results (1)There was significant difference of each index about LVEF and global strain between normal group and MI group (all P <0.05).(2)The correlations among LVEF and LVGLS,LVGCS,LVGRS,LVGAS were found (r =-0.626,-0.770,0.772,-0.748 respectively,P <0.01 for all).(3) Bland-Altman analysis showed there were good agreements in both patients with MI and control subjects.Conclusions 3D-STI could be applied non-invisibly and objective to assess alteration of myocardial global systolic function by accurately measuring strain.Therefore,3D-STI appears to be a reliable and useful tool to estimate the left ventricular systolic function of MI.%目的 应用超声三维斑点追踪技术评价心肌梗死患者的左室整体应变特征及与左室整体收缩功能的相关性.方法 使用三维斑点追踪技术对24例心肌梗死患者及20例正常人进行心肌运动分析,测量左室射血分数(LVEF),左室整体纵向、圆周、径向及面积收缩期峰值应变,并比较心肌梗死组与正常组之间的各应变指标变化情况及与LVEF的相关性.结果 三维斑点追踪技术测得心肌梗死患者的LVEF及各整体心肌应变参数均较正常组减低(P<0.05).心肌梗死组左室整体纵向、圆周、径向及面

  7. Quantification study of mitral valve with real-time three-dimensional transesophageal echocardiography before mitral valve replacement%实时三维超声心动图对二尖瓣置换术前瓣膜结构的定量研究

    Institute of Scientific and Technical Information of China (English)

    郎瑞; 冯天鹰; 哈斯

    2014-01-01

    目的 应用经食管实时三维超声心动图(RT-3D-TEE)对风湿性二尖瓣关闭不全行置换术的患者进行二尖瓣对合参数的对比研究.方法 风湿性二尖瓣关闭不全患者16例(风湿组;其中合并轻度狭窄者4例),其中男性6例,女性10例;年龄43~ 67岁,平均年龄53.4岁.正常对照组17例,其中男性7例,女性10例;年龄29 ~ 54岁,平均年龄43.1岁.分别行RT-3D-TEE检查并进行二尖瓣定量分析(MVQ).结果 风湿组在体二尖瓣对合面积为(160.69±50.44)mm2,术后离体瓣膜的对合面积为(163.97±59.58) mm2;对照组MVQ在体二尖瓣对合面积为(296.30±37.31) mm2.两组在体二尖瓣对合面积差异有显著统计学意义(t=8.82,P=0.000 00).MVQ所测二尖瓣对合面积与离体对合面积具有良好的相关性(r=0.892,P< 0.01).Altman-Bland绘图分析结果表明,二者具有较好的一致性,两者的差值为-1.73±8.28,95%的置信区间为(-18.04,14.46).风湿组左心室舒张早期及收缩末期瓣膜面积均较对照组增大(P<0.05),对合面积及对合指数减小(P<0.01).结论 RT-3D-TEE可以实时检测二尖瓣的立体结构,MVQ所测二尖瓣对合参数可以较好地反映二尖瓣的实际对合程度,为二尖瓣病变手术方案的制定及术后疗效的预测提供理论依据.%Objective To compare the mitral valve involution parameters in patients before and after mitral valve replacement by rheumatic mitral insufficiency using real-time three-dimensional transesophageal echocardiography(RT-3D-TEE).Methods A total of 16 patients with rheumatic mitral insufficiency(rheumatic group,and 4 cases combined mild stenosis) were enrolled,which included 6 males and 10 females,aged 43-67 years old with mean age of 53.4.The 17 healthy subjects was set as control group,included 7 males and 10 females,aged 29-54 years old with mean age of 43.1.The correlation parameters of mitral leaflets and annulars were obtained by mitral valve quantitative(MVQ) procedure

  8. 实时三维超声心动图评价冠心病患者PCI术前后左室功能及收缩同步性的研究%Study of left ventricular function and systolic synchrony assessed by real-time three-dimensional echocardiography before and after PCI in coronary heart disease patients

    Institute of Scientific and Technical Information of China (English)

    陈宏博; 刘和俊; 汪太平; 史学功; 金朝龙

    2012-01-01

    Objective To evaluate the influence left ventricular function and systolic synchrony assessed by realtime three-dimensional echocardiography( RT-3DE ) before and after percutaneous coronary intervention therapy ( PCI ) in coronary heart disease patients. Methods By using RT-3DE, the three-dimensional parameters were repeatedly measured in thirty-eight patients with PCI treatment as CHD group before operation, 1st week and 3rd month after operation. Twenty-eight nomal subjects were enrolled as control group. The left ventricular end-diastolic volume( LVEDV ), left ventricular end-systolic volume( LVESV ), left ventricular ejection fraction( LVEF ), left ventricular stroke volume ( LVSV ), left ventricular peak ejection rate( PER ), left ventricular peak filling rate ( PFR), the time of minimal systolic volume of 16-segmental standard deviation( Tmsvl6-SD% ) and maximum difference ( Tmsvl6-Dif% ) were analyzed with software. Results Compared with the control group, LVEDV, LVESV,Tmsvl6-SD% ,Tmsvl6-Dif% were significantly higher ( P <0. 01 ), while LVEF, PER/EDV, PFR/EDV were lower ( P < 0. 01 ) in study group befroe operation. Compared with the preoperative group, LVEDV, LVESV, Tmsvl6-SD% , Tmsvl6-Dif% reduced significantly ( P < 0. 05,P < 0. 01 ), while LVEF, PER/EDV, PFR/EDV increased ( P <0. 05 ,P < 0. 01 ) in postoperative group. The bull-eye diagram showed that systolic timing delayed and systolic excursion attenuated in segments reduced significantly with CHD group after the operation. Conclusion Left ventricular remodeling could be found in patients with coronary heart dease and PCI might reverse the left ventricular remodeling somewhat. RT-3DE could be a new corrected valuable method of evaluating left ventricular function and systolic synchrony in patients with CHD before and after PCI.%目的 应用实时三维超声心动图(RT-3DE)评价冠心病患者经皮冠状动脉介入(PCI)治疗术前后左室功能及收缩同步性的影响.方法

  9. 基于三维经食管超声的3D打印模型指导左心耳封堵的可行性研究%Guidance of three-dimensional printing model of left atrial appendage derived from transesophageal echocardiography for left atrial appendage closure

    Institute of Scientific and Technical Information of China (English)

    宋宏宁; 周青; 邓倾; 陈金玲; 张兰; 何发智; 潘一腾; 刘育; 郭瑞强

    2016-01-01

    Objective To investigate the feasibility of three dimensional printing left atrial appendage(LAA) models from three dimensional transesophageal echocardiography (3D-TEE) volume-rendered data and its value for guiding the placement of LAA occlusion device.Methods Ten patients with non-valvular atrial fibrillation (AF) were underwent TEE before LAA occlusion.3D full volume data and routine two dimensional images of the LAA were acquired.The 3D-TEE data were post-processed by grey values inverted imaging and threshold segmentation to create volume rendered images of the LAA in STL format.The cardiac chamber model and the cardiac wall model of the LAA were printed out by 3D printer for the LAA morphology evaluation and measurement.Preoperative rehearsal was carried out on the printed 3D LAA models.Results In all the patients,3D-TEE full volume data of the LAA were successfully reprocessed and printed out.In terms of the LAA morphology classification based on cardiac chamber models there were 5 chicken wing,3 windsock and 2 cauliflower.And there were 4 single-lobed,3 bi-lobed and 3 multi-lobed.The maximal ostium diameter and the depth of the main anchoring lobe were (20.30 ±3.53)mm and (28.26 ± 5.51)mm respectively,which were concordant well with the measurements of 2D-TEE and CT.The LAmbre and the Lefort occlusion device could be implanted into the 3D LAA models for occlusion planning before the procedure.Occlusion success rate was 100%.Conclusions 3D-TEE full volume data is feasible and capable of creating LAA 3D models.3D models of LAA derived from 3D-TEE have promising value in guiding the LAA occlusion procedure.%目的 探讨应用三维经食管超声(3D-TEE)心腔容积成像进行左心耳3D打印的技术可行性及该技术对左心耳封堵的指导价值.方法 10例因非瓣膜性心房颤动进行经导管左心耳封堵患者,术前行经食管超声心动图检查,采集左心耳二维图像及三维容积图像.对三维DICOM数据进行后处理

  10. Evaluation of left atrial function by three-dimensional speckle-tracking echocardiography in heart failure with preserved ejection fraction patients%三维斑点追踪技术对左室射血分数保留心衰患者左房功能的评估价值

    Institute of Scientific and Technical Information of China (English)

    刘峻松; 王晶; 张波; 刘博罕; 吕文青; 徐勇; 智光

    2015-01-01

    目的 应用三维斑点追踪技术(3D-STE)和实时三维超声心动图(RT3DE)评估探讨左室射血分数保留心衰(HFpEF)患者左房功能变化及意义.方法 将43例HFpEF患者根据左房大小分为A组(左房最大容积指数LAVImax< 34 mL/m2)和B组(LAVImax≥34 ml/m2),18例健康者为对照组.应用3 DSTE分析获取左房基底(Basal)、中间(Middle)、房顶(Roof)和整体(Global)的心室收缩期长轴峰值应变(LSs%)与心房收缩前长轴峰值应变(LSa%),结合RT3 DE和多普勒超声参数进行比较分析.结果 左房中部应变参数具满意可重复性(ICC >0.8),A组左房充盈和排空期形变功能减低以中部为主[与对照组相比:MLSs(33 ±6)%与(45±9)%,MLSa(12±3)%与(17±5)%;P<0.05],B组基底和房顶部形变功能也明显降低[与A组和对照组相比:BLSs(18 ±7)%与(25±8)%与(29±8)%,RLSs (24±9)%与(28±8)%与(32±10)%;与对照组相比:BLSa(11±5)%与(14士4)%,RLSa(12±5)%与(15±5)%;P<0.05].HFpEF患者左房僵硬度明显增加,左房充盈扩张分数(LAEI%)和被动射血分数(LAPEF%)明显降低,B组左房主动射血分数(LAAEF%)也显著降低.结论 3D-STE结合RT3DE可有效评估HFpEF左房功能.左房中部应变参数是评估左房功能的理想指标.HFpEF患者左房储备、通道和泵功能均明显降低,存在明显舒张功能不全,这些变化在左房明显增大患者中更为显著.%Objective To evaluate left atrial function changes inheart failure with preserved ejection fraction (HFpEF) patients by three-dimensional speckle-tracking echocardiography (3D-STE) and Real time three-dimensional echocardiograph(RT3DE).Methods 43 HFpEF patients and a control group with 18 healthy subjectswere enrolled.According to left atrial max volume index (LAVImax),patients were grouped as A (LAVImax < 34 ml/m2) and B (LAVImax≥34 ml/m2).3D-STE deformative parameters,left atrial ventricular-systolic longitudinal peak strain (LSs

  11. 实时三维超声和斑点追踪技术对慢性心衰患者左室再同步化治疗的评价%Assessment of the efficacy of cardiac resynchronization therapy using real-time three-dimensional echocardiography and speckle tracking imaging in patients with chronic heart failure

    Institute of Scientific and Technical Information of China (English)

    骆永娟; 关欣; 朱延波

    2016-01-01

    difference (Tmsv-16Dif). STl was used to evaluate the ratios of standard deviation of the time to peak longitudinal radial and circumferential strain to R-R interval (Tls-16SD%, Trs-16SD%,Tcs-16SD%) from the beginning of Q wave of electrocardiography to the point minimal systolic volume of all 16 segments and the maximum time difference. Results The values of LVEDV and LVESV were smaller 3 and 6 months after CRT than those before CRT. The value of LVEF was significantly improved after CRT (P < 0.05). The values of Tmsv-16SD%, Tmsv-16Dif%, Tls-16SD%, Trs-16SD%, Tcs-16SD%and T-Dif%were gradually decreased after CRT (P<0.05). The values of Tmsv-16SD%, Tmsv-16Dif%,Trs-16SD%and Tcs-16SD%were negatively related with LVEF (r=-0.79,-0.82,-0.69 and-0.74(P<0.05). The better consistency was found between RT-3DE and STI methods(Kappa=0.77). Conclusion Re⁃al-time three-dimensional echocardiography and speckle tracking imaging can provide more accurate quantitative informa⁃tion of cardiac resynchronization therapy for assessment of treatment and prognosis in patients with heart failure.

  12. Elastocapillary fabrication of three-dimensional microstructures

    NARCIS (Netherlands)

    Honschoten, van J.W.; Berenschot, J.W.; Ondarcuhu, T.; Sanders, R.G.P.; Sundaram, J.; Elwenspoek, M.; Tas, N.R.

    2010-01-01

    We describe the fabrication of three-dimensional microstructures by means of capillary forces. Using an origami-like technique, planar silicon nitride structures of various geometries are folded to produce three-dimensional objects of 50–100 m. Capillarity is a particularly effective mechanism since

  13. Three-Dimensional Gravity and String Ghosts

    OpenAIRE

    Carlip, S.; Kogan, I. I.

    1991-01-01

    It is known that much of the structure of string theory can be derived from three-dimensional topological field theory and gravity. We show here that, at least for simple topologies, the string diffeomorphism ghosts can also be explained in terms of three-dimensional physics.

  14. Preliminary study of three-dimensional speckle tracking echocardiography in evaluation of left ventricular systolic longitudinal strain in patients with uremia%三维斑点追踪技术评价不同透析时间尿毒症患者左心室心肌纵向应变的初步研究

    Institute of Scientific and Technical Information of China (English)

    沈丽君; 赵博文; 陈冉; 陈斌; 李世岩; 王蓓; 汤富刚

    2013-01-01

    Objective To evaluate the characteristics of left ventricular systolic longitudinal strain in uremic patients and its relationship with dialysis time using three-dimensional speckle tracking echocardiography (3D-STE).Methods Forty-six uremic patients were divided into three groups according dialysis time (ranged 0-5 years):group A (≤1 year),group B (1 year>time ≤3 years),group C (3 years >time≤5 years),group D was control group.The dynamic images of apical four chamber view were displayed and apical full-volume images were obtained and saved in all subjects using a full volume matrix probe.The original data was recorded and was analyzed by using off-line 3DT analysis software (TomTec 4D MV-Assessment).The longitudinal peak systolic strain and 16 segment systolic strains and strain mean value in 16 segment of left ventricular were acquired and compared.Results The peak strain of apical segment was lower than that of the basal segment and the middle segment and it had an increasing trend from the apical segment to the basal segment in three uremia groups.Instead,it had a decreasing trend from the apical segment to the basal segment in control group.But the differences were not statistically significant.The longitudinal peak systolic strain value,16 segment strain value and mean value of 16 segment strain all were lower in three uremic groups than those of control group.Every segment of 16 segment stain value in group A was higher than those of group B and C.There was no difference in every segment between B and C group in addition to basal and middle segment of anterior septum.Conclusions 3D-STE could evaluate the left ventricular systolic function in uremic patients and the cardiac function could be partly protected by regular dialysis treatment.%目的 利用三维斑点追踪技术(3D-STE)评价尿毒症患者左心室心肌整体及节段纵向应变特征,并探讨其左室应变能力与透析时间的关系.方法 将46例透析时间为0~5年的

  15. Three Dimensional Illustrating--Three-Dimensional Vision and Deception of Sensibility

    Science.gov (United States)

    Szállassy, Noémi; Gánóczy, Anita; Kriska, György

    2009-01-01

    The wide-spread digital photography and computer use gave the opportunity for everyone to make three-dimensional pictures and to make them public. The new opportunities with three-dimensional techniques give chance for the birth of new artistic photographs. We present in detail the biological roots of three-dimensional visualization, the phenomena…

  16. Three-Dimensional Imaging of a Central Venous Dialysis Catheter Related Infected Thrombus

    Directory of Open Access Journals (Sweden)

    Diana Yuan Yng Chiu

    2015-01-01

    Full Text Available Three-dimensional (3D echocardiography is becoming widely available and with novel applications. We report an interesting case of a 68-year-old lady with a central venous thrombosis coincident with both a dialysis catheter infection and a recent pacemaker insertion. Two-dimensional transesophageal echocardiography was unable to delineate whether the thrombosis was involved with the pacemaker wire or due to the tunneled catheter infection. The use of 3D echocardiography was able to produce distinct images aiding diagnosis. This circumvented the need for invasive investigations and inappropriate, high-risk removal of the pacing wire. This case highlights the emerging application of 3D echocardiography in routine nephrology practice.

  17. Three-Dimensional Imaging of a Central Venous Dialysis Catheter Related Infected Thrombus

    Science.gov (United States)

    Chiu, Diana Yuan Yng; Green, Darren; Kalra, Philip A.; Abidin, Nik

    2015-01-01

    Three-dimensional (3D) echocardiography is becoming widely available and with novel applications. We report an interesting case of a 68-year-old lady with a central venous thrombosis coincident with both a dialysis catheter infection and a recent pacemaker insertion. Two-dimensional transesophageal echocardiography was unable to delineate whether the thrombosis was involved with the pacemaker wire or due to the tunneled catheter infection. The use of 3D echocardiography was able to produce distinct images aiding diagnosis. This circumvented the need for invasive investigations and inappropriate, high-risk removal of the pacing wire. This case highlights the emerging application of 3D echocardiography in routine nephrology practice. PMID:26688761

  18. Device fabrication: Three-dimensional printed electronics

    Science.gov (United States)

    Lewis, Jennifer A.; Ahn, Bok Y.

    2015-02-01

    Can three-dimensional printing enable the mass customization of electronic devices? A study that exploits this method to create light-emitting diodes based on 'quantum dots' provides a step towards this goal.

  19. Three-Dimensional Icosahedral Phase Field Quasicrystal

    Science.gov (United States)

    Subramanian, P.; Archer, A. J.; Knobloch, E.; Rucklidge, A. M.

    2016-08-01

    We investigate the formation and stability of icosahedral quasicrystalline structures using a dynamic phase field crystal model. Nonlinear interactions between density waves at two length scales stabilize three-dimensional quasicrystals. We determine the phase diagram and parameter values required for the quasicrystal to be the global minimum free energy state. We demonstrate that traits that promote the formation of two-dimensional quasicrystals are extant in three dimensions, and highlight the characteristics required for three-dimensional soft matter quasicrystal formation.

  20. Three-dimensional imaging modalities in endodontics

    OpenAIRE

    Mao, Teresa; NEELAKANTAN, Prasanna

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualize...

  1. Three-dimensional imaging modalities in endodontics

    OpenAIRE

    Mao, Teresa; Neelakantan, Prasanna

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualize...

  2. [Stress echocardiography: development and significance].

    Science.gov (United States)

    Attenhofer, C; Ritter, M; Jenni, R

    1994-08-27

    Exercise electrocardiography is still the primary method used in the non-invasive assessment of coronary artery disease. Stress echocardiography is now being increasingly used as a more sensitive adjunct technique to assess ischemia. Ischemia provoked by stress can induce reversible wall motion abnormalities which are disclosed by cross-sectional 2-dimensional echocardiography and standard projections. The types of stress used are physical exercise (bicycle, treadmill), atrial pacing or pharmacologic stimulation. In the latter, the catecholamine dobutamine has emerged as preferable to the vasodilators dipyridamole and adenosine. The diagnostic accuracy of dobutamine stress echocardiography is comparable to that of bicycle or treadmill exercise echocardiography, but dobutamine stress echocardiography is technically simpler and can be performed in patients unable to exercise. Its sensitivity in diagnosing ischemic or viable myocardium is comparable to that of nuclear methods, MRI or PET. In contrast to nuclear methods, stress echocardiography is however free of radiation. In the assessment of patients with coronary artery disease, stress echocardiography has been shown to be valuable for diagnosis, preoperative risk stratification and determination of prognosis. Furthermore, low dose dobutamine echocardiography can be used to detect viable myocardium. Despite these very promising aspects of the method, there are recognized disadvantages and limitations: stress echocardiography is very time-consuming and operator-dependent; its sensitivity correlates strongly with the number of studies performed; analysis of wall motion is performed qualitatively on a purely subjective level, and hence lacks the objectivity of a quantitative approach. These factors emphasize the need for intensive research to render stress echocardiographic analysis more objective. Automatic boundary detection of left ventricular endocardium, color-Doppler-based tissue imaging and three-dimensional

  3. Transferring color between three-dimensional objects

    Science.gov (United States)

    Shen, Hui-Liang; Xin, John H.

    2005-04-01

    A framework for transferring image-based color between three-dimensional objects by the use of a dichromatic reflection model is proposed. The framework addresses the following issues: (1) accurate recovery of an implicit geometric coefficient, (2) calculation of body color, (3) color transfer between different illuminants, and (4) segmentation of multicolored regions. The experimental results show that high color accuracy and photorealistic effects of the synthesized images can be achieved. The proposed technique has wide applications in image-based design and visualization of three-dimensional objects.

  4. Two dimensional fermions in three dimensional YM

    CERN Document Server

    Narayanan, R

    2010-01-01

    Dirac fermions in the fundamental representation of $SU(N)$ live on the surface of a cylinder embedded in $R^3$ and interact with a three dimensional $SU(N)$ Yang Mills vector potential preserving a global chiral symmetry at finite $N$. As the circumference of the cylinder is varied from small to large, the chiral symmetry gets spontaneously broken in the infinite $N$ limit at a typical bulk scale. Replacing three dimensional YM by four dimensional YM introduces non-trivial renormalization effects.

  5. Three-Dimensional Robotic Vision System

    Science.gov (United States)

    Nguyen, Thinh V.

    1989-01-01

    Stereoscopy and motion provide clues to outlines of objects. Digital image-processing system acts as "intelligent" automatic machine-vision system by processing views from stereoscopic television cameras into three-dimensional coordinates of moving object in view. Epipolar-line technique used to find corresponding points in stereoscopic views. Robotic vision system analyzes views from two television cameras to detect rigid three-dimensional objects and reconstruct numerically in terms of coordinates of corner points. Stereoscopy and effects of motion on two images complement each other in providing image-analyzing subsystem with clues to natures and locations of principal features.

  6. Three dimensional dynamics of ferromagnetic swimmer

    Energy Technology Data Exchange (ETDEWEB)

    Erglis, K.; Livanovics, R. [Department of Physics, University of Latvia, Zellu 8, Ri-bar ga LV-1002 (Latvia); Cebers, A., E-mail: aceb@tesla.sal.l [Department of Physics, University of Latvia, Zellu 8, Ri-bar ga LV-1002 (Latvia)

    2011-05-15

    It is shown that a flexible ferromagnetic filament self-propels perpendicularly to the AC magnetic field during a limited period of time due to the instability of the planar motion with respect to three dimensional perturbations. The transition from the oscillating U-like shapes to the oscillating S-like shapes is characterized by the calculated Wr number. - Research Highlights: A ferromagnetic filament self-propels perpendicularly to the AC field. During the self-propulsion cycle the filament moves both forward and backward. The self-propulsion stops due to the three dimensional instability. The mechanism of the self-propulsion is similar to that used by some microorganisms.

  7. Three dimensional electrochemical system for neurobiological studies

    DEFF Research Database (Denmark)

    Vazquez, Patricia; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    In this work we report a novel three dimensional electrode array for electrochemical measurements in neuronal studies. The main advantage of working with these out-of-plane structures is the enhanced sensitivity of the system in terms of measuring electrochemical changes in the environment...

  8. Electron crystallography of three dimensional protein crystals

    NARCIS (Netherlands)

    Georgieva, Dilyana

    2008-01-01

    This thesis describes an investigation of the potential of electron diffraction for studying three dimensional sub-micro-crystals of proteins and pharmaceuticals. A prerequisite for using electron diffraction for structural studies is the predictable availability of tiny crystals. A method for grow

  9. Three dimensional measurement of rhinoplasty results.

    NARCIS (Netherlands)

    Heerbeek, N. van; Ingels, K.J.A.O.; Loon, B. van; Plooij, J.M.; Berge, S.J.

    2009-01-01

    BACKGROUND: Pre- and postoperative imaging is important and essential for evaluation of the results of rhinoplasty surgery. Two-dimensional photographs are used routinely for this purpose, but have several disadvantages as opposed to three-dimensional imaging techniques, such as

  10. Three-dimensional patterning methods and related devices

    Energy Technology Data Exchange (ETDEWEB)

    Putnam, Morgan C.; Kelzenberg, Michael D.; Atwater, Harry A.; Boettcher, Shannon W.; Lewis, Nathan S.; Spurgeon, Joshua M.; Turner-Evans, Daniel B.; Warren, Emily L.

    2016-12-27

    Three-dimensional patterning methods of a three-dimensional microstructure, such as a semiconductor wire array, are described, in conjunction with etching and/or deposition steps to pattern the three-dimensional microstructure.

  11. Two- and Three-dimensional Transthoracic Echocardiographic Assessment of Tricuspid Valve Prolapse with Mid-to-Late Systolic Tricuspid Regurgitation.

    Science.gov (United States)

    Elsayed, Mahmoud; Thind, Munveer; Nanda, Navin C

    2015-06-01

    We present the two-dimensional echocardiographic findings of tricuspid valve prolapse with mid-to-late systolic tricuspid regurgitation and describe the incremental value provided by live/real time three-dimensional transthoracic echocardiography. We also discuss a potential pitfall when assessing the severity of regurgitation in this setting.

  12. Deformations of three-dimensional metrics

    Science.gov (United States)

    Pugliese, Daniela; Stornaiolo, Cosimo

    2015-03-01

    We examine three-dimensional metric deformations based on a tetrad transformation through the action the matrices of scalar field. We describe by this approach to deformation the results obtained by Coll et al. (Gen. Relativ. Gravit. 34:269, 2002), where it is stated that any three-dimensional metric was locally obtained as a deformation of a constant curvature metric parameterized by a 2-form. To this aim, we construct the corresponding deforming matrices and provide their classification according to the properties of the scalar and of the vector used in Coll et al. (Gen Relativ Gravit 34:269, 2002) to deform the initial metric. The resulting causal structure of the deformed geometries is examined, too. Finally we apply our results to a spherically symmetric three geometry and to a space sector of Kerr metric.

  13. THREE DIMENSIONAL GRAPHICAL REPRESENTATION OF QUALITY

    Directory of Open Access Journals (Sweden)

    Vineet V. Kumar

    2014-03-01

    Full Text Available Quality is an important aspect for every firm in modern era of competition. Every product has tough competition in terms of market reach. The factor, which actually makes any product long run in market, is quality and hence quality is the stepping-stone for success of any firm. For everyone meaning of quality is different. We have seen several economists who have defined quality by considering different factors, but what all of them have common in them is Customer satisfaction. Customer satisfaction is the ultimate result of quality. In three-dimensional graphical representation of quality, optimum quality is obtained by using three-dimensional graph by considering some important factors governing quality of any product, limiting factor, and customer satisfaction.

  14. Three-dimensional broadband tunable terahertz metamaterials

    DEFF Research Database (Denmark)

    Fan, Kebin; Strikwerda, Andrew; Zhang, Xin

    2013-01-01

    We present optically tunable magnetic three-dimensional (3D) metamaterials at terahertz (THz) frequencies which exhibit a tuning range of ~30% of the resonance frequency. This is accomplished by fabricating 3D array structures consisting of double-split-ring resonators (DSRRs) on silicon on sapph......We present optically tunable magnetic three-dimensional (3D) metamaterials at terahertz (THz) frequencies which exhibit a tuning range of ~30% of the resonance frequency. This is accomplished by fabricating 3D array structures consisting of double-split-ring resonators (DSRRs) on silicon...... as verified through electromagnetic simulations and parameter retrieval. Our approach extends dynamic metamaterial tuning to magnetic control, and may find applications in switching and modulation, polarization control, or tunable perfect absorbers....

  15. Three-dimensional imaging modalities in endodontics

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Teresa; Neelakantan, Prasanna [Dept. of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha University, Chennai (India)

    2014-09-15

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

  16. Three-dimensional imaging modalities in endodontics.

    Science.gov (United States)

    Mao, Teresa; Neelakantan, Prasanna

    2014-09-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

  17. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  18. Three-Dimensional Printing in Orthopedic Surgery.

    Science.gov (United States)

    Eltorai, Adam E M; Nguyen, Eric; Daniels, Alan H

    2015-11-01

    Three-dimensional (3D) printing is emerging as a clinically promising technology for rapid prototyping of surgically implantable products. With this commercially available technology, computed tomography or magnetic resonance images can be used to create graspable objects from 3D reconstructed images. Models can enhance patients' understanding of their pathology and surgeon preoperative planning. Customized implants and casts can be made to match an individual's anatomy. This review outlines 3D printing, its current applications in orthopedics, and promising future directions.

  19. Lossless compression for three-dimensional images

    Science.gov (United States)

    Tang, Xiaoli; Pearlman, William A.

    2004-01-01

    We investigate and compare the performance of several three-dimensional (3D) embedded wavelet algorithms on lossless 3D image compression. The algorithms are Asymmetric Tree Three-Dimensional Set Partitioning In Hierarchical Trees (AT-3DSPIHT), Three-Dimensional Set Partitioned Embedded bloCK (3D-SPECK), Three-Dimensional Context-Based Embedded Zerotrees of Wavelet coefficients (3D-CB-EZW), and JPEG2000 Part II for multi-component images. Two kinds of images are investigated in our study -- 8-bit CT and MR medical images and 16-bit AVIRIS hyperspectral images. First, the performances by using different size of coding units are compared. It shows that increasing the size of coding unit improves the performance somewhat. Second, the performances by using different integer wavelet transforms are compared for AT-3DSPIHT, 3D-SPECK and 3D-CB-EZW. None of the considered filters always performs the best for all data sets and algorithms. At last, we compare the different lossless compression algorithms by applying integer wavelet transform on the entire image volumes. For 8-bit medical image volumes, AT-3DSPIHT performs the best almost all the time, achieving average of 12% decreases in file size compared with JPEG2000 multi-component, the second performer. For 16-bit hyperspectral images, AT-3DSPIHT always performs the best, yielding average 5.8% and 8.9% decreases in file size compared with 3D-SPECK and JPEG2000 multi-component, respectively. Two 2D compression algorithms, JPEG2000 and UNIX zip, are also included for reference, and all 3D algorithms perform much better than 2D algorithms.

  20. Three-dimensional display of document set

    Energy Technology Data Exchange (ETDEWEB)

    Lantrip, David B [Oxnard, CA; Pennock, Kelly A [Richland, WA; Pottier, Marc C [Richland, WA; Schur, Anne [Richland, WA; Thomas, James J [Richland, WA; Wise, James A [Richland, WA; York, Jeremy [Bothell, WA

    2009-06-30

    A method for spatializing text content for enhanced visual browsing and analysis. The invention is applied to large text document corpora such as digital libraries, regulations and procedures, archived reports, and the like. The text content from these sources may be transformed to a spatial representation that preserves informational characteristics from the documents. The three-dimensional representation may then be visually browsed and analyzed in ways that avoid language processing and that reduce the analysts' effort.

  1. Three-dimensional display of document set

    Energy Technology Data Exchange (ETDEWEB)

    Lantrip, David B. (Oxnard, CA); Pennock, Kelly A. (Richland, WA); Pottier, Marc C. (Richland, WA); Schur, Anne (Richland, WA); Thomas, James J. (Richland, WA); Wise, James A. (Richland, WA)

    2006-09-26

    A method for spatializing text content for enhanced visual browsing and analysis. The invention is applied to large text document corpora such as digital libraries, regulations and procedures, archived reports, and the like. The text content from these sources may e transformed to a spatial representation that preserves informational characteristics from the documents. The three-dimensional representation may then be visually browsed and analyzed in ways that avoid language processing and that reduce the analysts' effort.

  2. Three-Dimensional Dispaly Of Document Set

    Energy Technology Data Exchange (ETDEWEB)

    Lantrip, David B. (Oxnard, CA); Pennock, Kelly A. (Richland, WA); Pottier, Marc C. (Richland, WA); Schur, Anne (Richland, WA); Thomas, James J. (Richland, WA); Wise, James A. (Richland, WA)

    2003-06-24

    A method for spatializing text content for enhanced visual browsing and analysis. The invention is applied to large text document corpora such as digital libraries, regulations and procedures, archived reports, and the like. The text content from these sources may be transformed to a spatial representation that preserves informational characteristics from the documents. The three-dimensional representation may then be visually browsed and analyzed in ways that avoid language processing and that reduce the analysts' effort.

  3. Three-dimensional display of document set

    Energy Technology Data Exchange (ETDEWEB)

    Lantrip, David B [Oxnard, CA; Pennock, Kelly A [Richland, WA; Pottier, Marc C [Richland, WA; Schur, Anne [Richland, WA; Thomas, James J [Richland, WA; Wise, James A [Richland, WA

    2001-10-02

    A method for spatializing text content for enhanced visual browsing and analysis. The invention is applied to large text document corpora such as digital libraries, regulations and procedures, archived reports, and the like. The text content from these sources may be transformed to a spatial representation that preserves informational characteristics from the documents. The three-dimensional representation may then be visually browsed and analyzed in ways that avoid language processing and that reduce the analysts' effort.

  4. Three-Dimensional Ocean Noise Modeling

    Science.gov (United States)

    2015-03-01

    particular attention paid to the case of Gaussian canyon . The solution to the three-dimensional wave equation in Cartesian co-ordinates can be written...in terms of a modal decomposition, carried out in the vertical and across- canyon horizontal directions. Work Completed 1. Nx2D and 3D Noise PE...azimuth in the Hudson Canyon [Figure 2). Additionally, the PE-reciprocity noise model was used to estimate the size, speed and distance from the

  5. Three dimensional boundary layers in internal flows

    Science.gov (United States)

    Bodonyi, R. J.

    1987-01-01

    A numerical study of the effects of viscous-inviscid interactions in three-dimensional duct flows is presented. In particular interacting flows for which the oncoming flow is not fully-developed were considered. In this case there is a thin boundary layer still present upstream of the surface distortion, as opposed to the fully-developed pipe flow situation wherein the flow is viscous across the cross section.

  6. Multiparallel Three-Dimensional Optical Microscopy

    Science.gov (United States)

    Nguyen, Lam K.; Price, Jeffrey H.; Kellner, Albert L.; Bravo-Zanoquera, Miguel

    2010-01-01

    Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.

  7. Imaging unsteady three-dimensional transport phenomena

    Indian Academy of Sciences (India)

    K Muralidhar

    2014-01-01

    Careful and continuous measurements of flow, heat and mass transfer are required in quite a few contexts. Using appropriate light sources, it is possible to map velocity, temperature, and species concentration over a cross-section and as a function of time. Image formation in optical measurements may rely on scattering of radiation from particles. Alternatively, if the region of interest is transparent, refractive index would be a field variable and beam bending effects can be used to extract information about temperature and concentration of solutes dissolved in liquids. Time-lapsed images of light intensity can be used to determine fluid velocity. Though used originally for flow visualization, optical imaging has now emerged as a powerful tool for quantitative measurements. Optical methods that utilize the dependence of refractive index on concentration and temperature can be configured in many different ways. Three available routes considered are interferometry, schlieren imaging, and shadowgraph. Images recorded in these configurations can be analysed to yield time sequences of three-dimensional distributions of the transported variables. Optical methods are non-intrusive, inertia-free and can image cross-sections of the experimental apparatus. The image data can be jointly analysed with the physical laws governing transport and principles of image formation. Hence, with the experiment suitably carried out, three-dimensional physical domains with unsteady processes can be accommodated. Optical methods promise to breach the holy grail of measurements by extracting unsteady three-dimensional data in applications related to transport phenomena.

  8. Volumetric Three-Dimensional Display Systems

    Science.gov (United States)

    Blundell, Barry G.; Schwarz, Adam J.

    2000-03-01

    A comprehensive study of approaches to three-dimensional visualization by volumetric display systems This groundbreaking volume provides an unbiased and in-depth discussion on a broad range of volumetric three-dimensional display systems. It examines the history, development, design, and future of these displays, and considers their potential for application to key areas in which visualization plays a major role. Drawing substantially on material that was previously unpublished or available only in patent form, the authors establish the first comprehensive technical and mathematical formalization of the field, and examine a number of different volumetric architectures. System level design strategies are presented, from which proposals for the next generation of high-definition predictable volumetric systems are developed. To ensure that researchers will benefit from work already completed, they provide: * Descriptions of several recent volumetric display systems prepared from material supplied by the teams that created them * An abstract volumetric display system design paradigm * An historical summary of 90 years of development in volumetric display system technology * An assessment of the strengths and weaknesses of many of the systems proposed to date * A unified presentation of the underlying principles of volumetric display systems * A comprehensive bibliography Beautifully supplemented with 17 color plates that illustrate volumetric images and prototype displays, Volumetric Three-Dimensional Display Systems is an indispensable resource for professionals in imaging systems development, scientific visualization, medical imaging, computer graphics, aerospace, military planning, and CAD/CAE.

  9. Three dimensional illustrating - three-dimensional vision and deception of sensibility

    Directory of Open Access Journals (Sweden)

    Anita Gánóczy

    2009-03-01

    Full Text Available The wide-spread digital photography and computer use gave the opportunity for everyone to make three-dimensional pictures and to make them public. The new opportunities with three-dimensional techniques give chance for the birth of new artistic photographs. We present in detail the biological roots of three-dimensional visualization, the phenomena of movement parallax, which can be used efficiently in making three-dimensional graphics, the Zöllner- and Corridor-illusion. There are present in this paper the visual elements, which contribute to define a plane two-dimensional image in three-dimension: coherent lines, the covering, the measurement changes, the relative altitude state, the abatement of detail profusion, the shadings and the perspective effects of colors.

  10. Three-dimensional analysis of craniofacial bones using three-dimensional computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Ichiro; Ohura, Takehiko; Kimura, Chu (Hokkaido Univ., Sapporo (Japan). School of Medicine) (and others)

    1989-08-01

    Three-dimensional computer tomography (3DCT) was performed in patients with various diseases to visualize stereoscopically the deformity of the craniofacial bones. The data obtained were analyzed by the 3DCT analyzing system. A new coordinate system was established using the median sagittal plane of the face (a plane passing through sella, nasion and basion) on the three-dimensional image. Three-dimensional profilograms were prepared for detailed analysis of the deformation of craniofacial bones for cleft lip and palate, mandibular prognathia and hemifacial microsomia. For patients, asymmetry in the frontal view and twist-formed complicated deformities were observed, as well as deformity of profiles in the anteroposterior and up-and-down directions. A newly developed technique allows three-dimensional visualization of changes in craniofacial deformity. It would aid in determining surgical strategy, including crani-facial surgery and maxillo-facial surgery, and in evaluating surgical outcome. (N.K.).

  11. Stress echocardiography

    NARCIS (Netherlands)

    A. Salustri (Alessandro)

    1993-01-01

    textabstractIn the studies reported in this thesis, stress echocardiography (either with exercise or with pharmacological agents) and myocardial perfusion scintigraphy have been performed in different groups of patients and in different clinical conditions. Some practical aspects on the protocols of

  12. Stress echocardiography

    NARCIS (Netherlands)

    A. Salustri (Alessandro)

    1993-01-01

    textabstractIn the studies reported in this thesis, stress echocardiography (either with exercise or with pharmacological agents) and myocardial perfusion scintigraphy have been performed in different groups of patients and in different clinical conditions. Some practical aspects on the protocols

  13. Stability of three-dimensional boundary layers

    Science.gov (United States)

    Nayfeh, A. H.

    1979-01-01

    A theory is presented for the three-dimensional stability of boundary layers. Equations are derived for the evolution of a disturbance having a given frequency and originating at a given curve. These equations are used to determine the rays along which the disturbance energy propagates. It is shown that the results can be obtained by using the saddle-point method, or kinematic wave theory, or the method of multiple scales. Extension of the theory to the case of a wave packet is also presented.

  14. Nonparallel stability of three-dimensional flows

    Science.gov (United States)

    Padhye, A. R.; Nayfeh, A. H.

    1981-01-01

    The linear stability of three-dimensional incompressible, isothermal, nonparallel boundary-layer flows has been investigated. The method of multiple scales is used to derive the partial-differential equations that describe the spatial modulations of the amplitude, phase and wavenumber of a disturbance. Group velocities are used to determine the disturbance growth direction. The envelope method is used to calculate the logarithmic amplitude growth rate N. The theory is applied to the flows over a swept-back tapered wing with boundary-layer suction. Results of such analysis for the X-21 wing are discussed. It is found that the nonparallel effects for this wing is substantial.

  15. Stabilization of Three-Dimensional Collective Motion

    CERN Document Server

    Scardovi, Luca; Sepulchre, Rodolphe

    2008-01-01

    This paper proposes a methodology to stabilize relative equilibria in a model of identical, steered particles moving in three-dimensional Euclidean space. Exploiting the Lie group structure of the resulting dynamical system, the stabilization problem is reduced to a consensus problem on the Lie algebra. The resulting equilibria correspond to parallel, circular and helical formations. We first derive the stabilizing control laws in the presence of all-to-all communication. Providing each agent with a consensus estimator, we then extend the results to a general setting that allows for unidirectional and time-varying communication topologies.

  16. Three-dimensional cooling of muons

    CERN Document Server

    Vsevolozhskaya, T A

    2000-01-01

    The simultaneous ionization cooling of muon beams in all three - the longitudinal and two transverse - directions is considered in a scheme, based on bent lithium lenses with dipole constituent of magnetic field in them, created by a special configuration of current-carrying rod. An analysis of three-dimensional cooling is performed with the use of kinetic equation method. Results of numerical calculation for a specific beam line configuration are presented together with results of computer simulation using the Moliere distribution to describe the Coulomb scattering and the Vavilov distribution used to describe the ionization loss of energy.

  17. Three dimensional dilatonic gravity's rainbow: exact solutions

    CERN Document Server

    Hendi, Seyed Hossein; Panahiyan, Shahram

    2016-01-01

    Deep relations of dark energy scenario and string theory results with dilaton gravity, on one hand, and the connection between quantum gravity with gravity's rainbow, on the other hand, motivate us to consider three dimensional dilatonic black hole solutions in gravity's rainbow. We obtain two classes of the solutions which are polynomial and logarithmic forms. We also calculate conserved and thermodynamic quantities, and examine the first law of thermodynamics for both classes. In addition, we study thermal stability and show that one of the classes is thermally stable while the other one is unstable.

  18. Recent advances in echocardiography for nuclear medicine physician

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Geu Ru; Shin, Dong Gu [Yeungnam University College of Medicine, Daegu (Korea, Republic of)

    2005-10-15

    Echocardiography is one of the most frequently used techniques for diagnosing cardiovascular diseases. Over the last twenty years, technological advances have enabled the application of high-quality imaging. Important recent developments have occurred in echocardiography that are already being used clinically. Equipment and hardware is now available to produce real time three-dimensional and contrast enhanced imaging. Tissue Doppler and stress echocardiography have provided potential benefit to analyze hemodynamic information of heart. This review discusses each of these new developments and their potential impact on the practice of echocardiography and cardiology in general.

  19. Assessment of left ventricular global systolic and diastolic function using volume-time curves by real-time three-dimensional echocardiography%实时三维超声心动图容积时间曲线评价左心室整体收缩和舒张功能

    Institute of Scientific and Technical Information of China (English)

    魏常华; 袁建军; 苑淑姣

    2008-01-01

    Objective To quantitatively assess left ventricular global systolic and diastolic function using volume-time curves (VTC) by real-time three-dimensional echoeardiography(RT-3DE).Methods Ninty-eight subjects were divided into four groups.Group A consisted of twenty-eight normal subject,group B included twenty-four patients with hypertensive(HTN), group C consisted of twenty-four patients with coronary artery disease(CAD) and group D of twenty-two patients having dilated cordiomyopathy (DCM).Participants were selected undergoing full volume RT-3DE.The global and 17-segmental VTCs were obtained by the off-line Qlab software.The end-diastolic volume(EDV), end-systolic volume(ESV) and ejection fraction(EF) were derived from VTCs.The peak ejection rate(PER),peak early filling rate (PFR),PER/EDV and PFR/EDV were calculted.Results EDV and ESV of group B,C and D was significantly larger than that of group A(all P < 0.05), EF and PER/EDV of group C and D significantly lower than those of group A.There were close correlation between PER/EDV and EF ( r=0.694, P<0.05).Comparison of VTC pattern of HTN,CAD and DCM with that of healthy participants revealed the loss of symmetry of systolic and diastolic pattern.Conclusions Generation of VTCs by RT3DE is a promising approach to evaluate left ventricular global systolic and diastolic function.PER/EDV and PFR/EDV may be potential parameters for assessing left ventricular global systolic and diastolic function.%目的 应用实时三维超声心动图(RT-3DE)容积-时间曲线(VTC)定量评价左心室整体收缩和舒张功能.方法 98例研究对象分为4组:A组,正常人28例;B组,高血压病患者24例;C组,冠心病患者24例;D组,扩张性心肌病22例.对所有研究对象进行RT-3DE检查,采集全容积三维图像,应用Qlab分析软件对三维数据库进行分析,得到左室整体和17节段容积时间曲线,测量舒张末容积(EDV)、收缩末容积(ESV)和左室射血分数(EF),并计算峰值射血

  20. The Application of Real-time Three-dimensional Tansesophageal Echocardiography in Aorta Petal Replacement Technique%经食管实时三维超声心动图在主动脉瓣置换术中的应用

    Institute of Scientific and Technical Information of China (English)

    张瑜; 丁云川; 尹帆; 陈剑; 罗庆祎; 王庆慧

    2013-01-01

    Objective To discuss the clinical practice value of the transesophageal real-time three dimensional echocardiogram (RT-3DTEE) in the aorta petal artificial valve replacement technique. Methods 25 cases of aorta petal replacement technique and 31 cases of bicuspid valve and the aorta petal replacement technique were given RT-3DTEE and the examination results were compared with the results of surgical operation. Results Surgery was successfully performed in 56 cases, and fine RT-3 DTEE images were obtained. Among the 56 cases, 1 case had granulation around artificial valve, artificial aortic valve stenosis and regurgitation, and was given the elimination of periprosthetic granulation and successful re-aortic valve replacement after determining the location of granulation by RT-3 DTEE; 1 case were found with the entire artificial mechanical petal and the perivalvular leak and timely treated by RT-3DTEE after cardiac resuscitation. 1 case were found with asynchronous opening of two artificial aorta petal leaves due to the dysfunction of the left ventrium muscle contraction and treated timely after cardiac resuscitation. Conclusion The RT-3DTEE is a direct-viewing, fast and accurate assessment method in the aorta petal replacement technique.%目的 探讨经食管实时三维超声心动图在主动脉瓣人工瓣膜置换术中的临床应用价值.方法 运用经食管实时三维超声心动图对25例主动脉瓣置换术,31例二尖瓣及主动脉瓣置换术患者的主动脉瓣环经(AAD)进行观测,结果与二维AAD测值外科手术中所选机械瓣型号对比.结果 56例患者手术顺利,获得满意RT-3DTEE图像,其中1例患者为瓣周肉芽、人工主动脉瓣狭窄并关闭不全,在RT-3DTEE确定肉芽生长位置,手术彻底清除瓣周肉芽,并成功完成再次主动脉瓣置换术.1例术中心脏复跳后RT-3DTEE发现清晰显示人工机械瓣及瓣周瘘的全貌,进行补救;1例患者心脏复跳后,发现因左室心肌收缩乏

  1. Two component-three dimensional catalysis

    Science.gov (United States)

    Schwartz, Michael; White, James H.; Sammells, Anthony F.

    2002-01-01

    This invention relates to catalytic reactor membranes having a gas-impermeable membrane for transport of oxygen anions. The membrane has an oxidation surface and a reduction surface. The membrane is coated on its oxidation surface with an adherent catalyst layer and is optionally coated on its reduction surface with a catalyst that promotes reduction of an oxygen-containing species (e.g., O.sub.2, NO.sub.2, SO.sub.2, etc.) to generate oxygen anions on the membrane. The reactor has an oxidation zone and a reduction zone separated by the membrane. A component of an oxygen containing gas in the reduction zone is reduced at the membrane and a reduced species in a reactant gas in the oxidation zone of the reactor is oxidized. The reactor optionally contains a three-dimensional catalyst in the oxidation zone. The adherent catalyst layer and the three-dimensional catalyst are selected to promote a desired oxidation reaction, particularly a partial oxidation of a hydrocarbon.

  2. Three-dimensional flow in Kupffer's Vesicle

    CERN Document Server

    Montenegro-Johnson, Thomas D; Smith, David J; Lopes, Susana S

    2016-01-01

    Whilst many vertebrates appear externally left-right symmetric, the arrangement of internal organs is asymmetric. In zebrafish, the breaking of left-right symmetry is organised by Kupffer's Vesicle (KV): an approximately spherical, fluid-filled structure that begins to form in the embryo 10 hours post fertilisation. A crucial component of zebrafish symmetry breaking is the establishment of a cilia-driven fluid flow within KV. However, it is still unclear (a) how dorsal, ventral and equatorial cilia contribute to the global vortical flow, and (b) if this flow breaks left-right symmetry through mechanical transduction or morphogen transport. Fully answering these questions requires knowledge of the three-dimensional flow patterns within KV, which have not been quantified in previous work. In this study, we calculate and analyse the three-dimensional flow in KV. We consider flow from both individual and groups of cilia, and (a) find anticlockwise flow can arise purely from excess of cilia on the dorsal roof over...

  3. Three dimensional force balance of asymmetric droplets

    Science.gov (United States)

    Kim, Yeseul; Lim, Su Jin; Cho, Kun; Weon, Byung Mook

    2016-11-01

    An equilibrium contact angle of a droplet is determined by a horizontal force balance among vapor, liquid, and solid, which is known as Young's law. Conventional wetting law is valid only for axis-symmetric droplets, whereas real droplets are often asymmetric. Here we show that three-dimensional geometry must be considered for a force balance for asymmetric droplets. By visualizing asymmetric droplets placed on a free-standing membrane in air with X-ray microscopy, we are able to identify that force balances in one side and in other side control pinning behaviors during evaporation of droplets. We find that X-ray microscopy is powerful for realizing the three-dimensional force balance, which would be essential in interpretation and manipulation of wetting, spreading, and drying dynamics for asymmetric droplets. This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2016R1D1A1B01007133).

  4. Three dimensional quantum geometry and deformed symmetry

    Science.gov (United States)

    Joung, E.; Mourad, J.; Noui, K.

    2009-05-01

    We study a three dimensional noncommutative space emerging in the context of three dimensional Euclidean quantum gravity. Our starting point is the assumption that the isometry group is deformed to the Drinfeld double D(SU(2)). We generalize to the deformed case the construction of E3 as the quotient of its isometry group ISU(2) by SU(2). We show that the algebra of functions on E3 becomes the noncommutative algebra of SU(2) distributions, C(SU(2))∗, endowed with the convolution product. This construction gives the action of ISU(2) on the algebra and allows the determination of plane waves and coordinate functions. In particular, we show the following: (i) plane waves have bounded momenta; (ii) to a given momentum are associated several SU(2) elements leading to an effective description of ϕ ɛC(SU(2))∗ in terms of several physical scalar fields on E3; (iii) their product leads to a deformed addition rule of momenta consistent with the bound on the spectrum. We generalize to the noncommutative setting the "local" action for a scalar field. Finally, we obtain, using harmonic analysis, another useful description of the algebra as the direct sum of the algebra of matrices. The algebra of matrices inherits the action of ISU(2): rotations leave the order of the matrices invariant, whereas translations change the order in a way we explicitly determine.

  5. Three-dimensional image signals: processing methods

    Science.gov (United States)

    Schiopu, Paul; Manea, Adrian; Craciun, Anca-Ileana; Craciun, Alexandru

    2010-11-01

    Over the years extensive studies have been carried out to apply coherent optics methods in real-time processing, communications and transmission image. This is especially true when a large amount of information needs to be processed, e.g., in high-resolution imaging. The recent progress in data-processing networks and communication systems has considerably increased the capacity of information exchange. We describe the results of literature investigation research of processing methods for the signals of the three-dimensional images. All commercially available 3D technologies today are based on stereoscopic viewing. 3D technology was once the exclusive domain of skilled computer-graphics developers with high-end machines and software. The images capture from the advanced 3D digital camera can be displayed onto screen of the 3D digital viewer with/ without special glasses. For this is needed considerable processing power and memory to create and render the complex mix of colors, textures, and virtual lighting and perspective necessary to make figures appear three-dimensional. Also, using a standard digital camera and a technique called phase-shift interferometry we can capture "digital holograms." These are holograms that can be stored on computer and transmitted over conventional networks. We present some research methods to process "digital holograms" for the Internet transmission and results.

  6. Three-dimensional printing physiology laboratory technology.

    Science.gov (United States)

    Sulkin, Matthew S; Widder, Emily; Shao, Connie; Holzem, Katherine M; Gloschat, Christopher; Gutbrod, Sarah R; Efimov, Igor R

    2013-12-01

    Since its inception in 19th-century Germany, the physiology laboratory has been a complex and expensive research enterprise involving experts in various fields of science and engineering. Physiology research has been critically dependent on cutting-edge technological support of mechanical, electrical, optical, and more recently computer engineers. Evolution of modern experimental equipment is constrained by lack of direct communication between the physiological community and industry producing this equipment. Fortunately, recent advances in open source technologies, including three-dimensional printing, open source hardware and software, present an exciting opportunity to bring the design and development of research instrumentation to the end user, i.e., life scientists. Here we provide an overview on how to develop customized, cost-effective experimental equipment for physiology laboratories.

  7. Three-dimensional context regulation of metastasis.

    Science.gov (United States)

    Erler, Janine T; Weaver, Valerie M

    2009-01-01

    Tumor progression ensues within a three-dimensional microenvironment that consists of cellular and non-cellular components. The extracellular matrix (ECM) and hypoxia are two non-cellular components that potently influence metastasis. ECM remodeling and collagen cross-linking stiffen the tissue stroma to promote transformation, tumor growth, motility and invasion, enhance cancer cell survival, enable metastatic dissemination, and facilitate the establishment of tumor cells at distant sites. Matrix degradation can additionally promote malignant progression and metastasis. Tumor hypoxia is functionally linked to altered stromal-epithelial interactions. Hypoxia additionally induces the expression of pro-migratory, survival and invasion genes, and up-regulates expression of ECM components and modifying enzymes, to enhance tumor progression and metastasis. Synergistic interactions between matrix remodeling and tumor hypoxia influence common mechanisms that maximize tumor progression and cooperate to drive metastasis. Thus, clarifying the molecular pathways by which ECM remodeling and tumor hypoxia intersect to promote tumor progression should identify novel therapeutic targets.

  8. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  9. Entanglement entropy in three dimensional gravity

    CERN Document Server

    Maxfield, Henry

    2014-01-01

    The Ryu-Takayanagi and covariant Hubeny-Rangamani-Takayanagi proposals relate entanglement entropy in CFTs with holographic duals to the areas of minimal or extremal surfaces in the bulk geometry. We show how, in three dimensional pure gravity, the relevant regulated geodesic lengths can be obtained by writing a spacetime as a quotients of AdS3, with the problem reduced to a simple purely algebraic calculation. We explain how this works in both Lorentzian and Euclidean formalisms, before illustrating its use to obtain novel results in a number of examples, including rotating BTZ, the RP2 geon, and several wormhole geometries. This includes spatial and temporal dependence of single-interval entanglement entropy, despite these symmetries being broken only behind an event horizon. We also discuss considerations allowing HRT to be derived from analytic continuation of Euclidean computations in certain contexts, and a related class of complexified extremal surfaces.

  10. Three-Dimensional Pneumatic Molding of Veneers

    Directory of Open Access Journals (Sweden)

    Milan Gaff

    2014-07-01

    Full Text Available The goal of this paper is to introduce a new testing method suitable for the evaluation of the three-dimensional (3-D moldability of veneers and to use this method to test the impact of specific factors on the 3-D pneumatic molding process. The tested factors included veneer moisture content, wood species, shape of test piece, and fixing method on the maximum wood deflection. Veneers were molded using compressed air on equipment designed by our group for the sole purpose of this experiment. The results indicated that the monitored factors had an effect on deflection during the 3-D molding process. The results of this investigation extend the state-of-the-art knowledge regarding this technology and indicate the possibility of utilizing this innovative testing method for 3-D molded veneers.

  11. Three dimensional fabric evolution of sheared sand

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, Alsidqi; Alshibli, Khalid (UWA)

    2012-10-24

    Granular particles undergo translation and rolling when they are sheared. This paper presents a three-dimensional (3D) experimental assessment of fabric evolution of sheared sand at the particle level. F-75 Ottawa sand specimen was tested under an axisymmetric triaxial loading condition. It measured 9.5 mm in diameter and 20 mm in height. The quantitative evaluation was conducted by analyzing 3D high-resolution x-ray synchrotron micro-tomography images of the specimen at eight axial strain levels. The analyses included visualization of particle translation and rotation, and quantification of fabric orientation as shearing continued. Representative individual particles were successfully tracked and visualized to assess the mode of interaction between them. This paper discusses fabric evolution and compares the evolution of particles within and outside the shear band as shearing continues. Changes in particle orientation distributions are presented using fabric histograms and fabric tensor.

  12. Dual solutions for three-dimensional

    Directory of Open Access Journals (Sweden)

    C.S.K. Raju

    2016-03-01

    Full Text Available In this study we investigated the effect of space and temperature dependent heat generation/absorption on three-dimensional magnetohydrodynamic nanofluid flow over a nonlinearly permeable stretching sheet. After using appropriate self-similarity transformation the governing equations are solved numerically using bvp4c Matlab package. The effects of the non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed with the help of graphs. Also, coefficient of skin friction and Nusselt number is analyzed and presented through tables. It is found that present results have an excellent agreement with the existed studies under some special cases. Results indicate that an increase in space and temperature dependent heat source or sink increases the temperature and concentration profiles of the flow. Dual solutions exist only for certain range of power-law index.

  13. Three-Dimensional Reflectance Traction Microscopy.

    Directory of Open Access Journals (Sweden)

    Jihan Kim

    Full Text Available Cells in three-dimensional (3D environments exhibit very different biochemical and biophysical phenotypes compared to the behavior of cells in two-dimensional (2D environments. As an important biomechanical measurement, 2D traction force microscopy can not be directly extended into 3D cases. In order to quantitatively characterize the contraction field, we have developed 3D reflectance traction microscopy which combines confocal reflection imaging and partial volume correlation postprocessing. We have measured the deformation field of collagen gel under controlled mechanical stress. We have also characterized the deformation field generated by invasive breast cancer cells of different morphologies in 3D collagen matrix. In contrast to employ dispersed tracing particles or fluorescently-tagged matrix proteins, our methods provide a label-free, computationally effective strategy to study the cell mechanics in native 3D extracellular matrix.

  14. Steady inviscid three-dimensional flows

    Science.gov (United States)

    Adamczyk, J. J.; Chang, S.-C.

    1985-01-01

    The present analysis combines some of the theoretical concepts suggested by Hawthorne (1955) with a numerical integration procedure suggested by Martin (1978). The resulting algorithm is for inviscid subsonic flows. Thus, it is restricted to high Reynolds number flows. Chang and Adamczyk (1983) have provided a detailed derivation of the present algorithm along with a discussion of its stability bounds. The present paper represents a summary of this work. The integration of the continuity equation is considered along with an evaluation of the entropy, total temperature, and vorticity field. Attention is given to the shear-flow algorithm construction, and an application to a shear flow in a turning channel. A description of numerical results is also provided. The discussed algorithm represents a new procedure for solving inviscid subsonic three-dimensional rotational flows.

  15. Scaffolding for Three-Dimensional Embryonic Vasculogenesis

    Science.gov (United States)

    Kraehenbuehl, Thomas P.; Aday, Sezin; Ferreira, Lino S.

    Biomaterial scaffolds have great potential to support efficient vascular differentiation of embryonic stem cells. Vascular cell fate-specific biochemical and biophysical cues have been identified and incorporated into three-dimensional (3D) biomaterials to efficiently direct embryonic vasculogenesis. The resulting vascular-like tissue can be used for regenerative medicine applications, further elucidation of biophysical and biochemical cues governing vasculogenesis, and drug discovery. In this chapter, we give an overview on the following: (1) developmental cues for directed differentiation of human embryonic stem cells (hESCs) into vascular cells, (2) 3D vascular differentiation in embryoid bodies (EBs), (3) preparation of 3D scaffolds for the vascular differentiation of hESCs, and (4) the most significant studies combining scaffolding and hESCs for development of vascular-like tissue.

  16. Three-dimensional tori and Arnold tongues

    Energy Technology Data Exchange (ETDEWEB)

    Sekikawa, Munehisa, E-mail: sekikawa@cc.utsunomiya-u.ac.jp [Department of Mechanical and Intelligent Engineering, Utsunomiya University, Utsunomiya-shi 321-8585 (Japan); Inaba, Naohiko [Organization for the Strategic Coordination of Research and Intellectual Property, Meiji University, Kawasaki-shi 214-8571 (Japan); Kamiyama, Kyohei [Department of Electronics and Bioinformatics, Meiji University, Kawasaki-shi 214-8571 (Japan); Aihara, Kazuyuki [Institute of Industrial Science, the University of Tokyo, Meguro-ku 153-8505 (Japan)

    2014-03-15

    This study analyzes an Arnold resonance web, which includes complicated quasi-periodic bifurcations, by conducting a Lyapunov analysis for a coupled delayed logistic map. The map can exhibit a two-dimensional invariant torus (IT), which corresponds to a three-dimensional torus in vector fields. Numerous one-dimensional invariant closed curves (ICCs), which correspond to two-dimensional tori in vector fields, exist in a very complicated but reasonable manner inside an IT-generating region. Periodic solutions emerge at the intersections of two different thin ICC-generating regions, which we call ICC-Arnold tongues, because all three independent-frequency components of the IT become rational at the intersections. Additionally, we observe a significant bifurcation structure where conventional Arnold tongues transit to ICC-Arnold tongues through a Neimark-Sacker bifurcation in the neighborhood of a quasi-periodic Hopf bifurcation (or a quasi-periodic Neimark-Sacker bifurcation) boundary.

  17. Entanglement entropy in three dimensional gravity

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, Henry [Centre for Particle Theory & Department of Mathematical Sciences, Durham University,South Road, Durham DH1 3LE (United Kingdom)

    2015-04-07

    The Ryu-Takayanagi (RT) and covariant Hubeny-Rangamani-Takayanagi (HRT) proposals relate entanglement entropy in CFTs with holographic duals to the areas of minimal or extremal surfaces in the bulk geometry. We show how, in three dimensional pure gravity, the relevant regulated geodesic lengths can be obtained by writing a spacetime as a quotient of AdS{sub 3}, with the problem reduced to a simple purely algebraic calculation. We explain how this works in both Lorentzian and Euclidean formalisms, before illustrating its use to obtain novel results in a number of examples, including rotating BTZ, the ℝℙ{sup 2} geon, and several wormhole geometries. This includes spatial and temporal dependence of single-interval entanglement entropy, despite these symmetries being broken only behind an event horizon. We also discuss considerations allowing HRT to be derived from analytic continuation of Euclidean computations in certain contexts, and a related class of complexified extremal surfaces.

  18. AAOGlimpse: Three-dimensional Data Viewer

    Science.gov (United States)

    Shortridge, Keith

    2011-10-01

    AAOGlimpse is an experimental display program that uses OpenGL to display FITS data (and even JPEG images) as 3D surfaces that can be rotated and viewed from different angles, all in real-time. It is WCS-compliant and designed to handle three-dimensional data. Each plane in a data cube is surfaced in the same way, and the program allows the user to travel through a cube by 'peeling off' successive planes, or to look into a cube by suppressing the display of data below a given cutoff value. It can blink images and can superimpose images and contour maps from different sources using their world coordinate data. A limited socket interface allows communication with other programs.

  19. Three dimensional polymer waveguide using hybrid lithography.

    Science.gov (United States)

    Wang, Huanran; Liu, Yu; Jiang, Minghui; Chen, Changming; Wang, Xibin; Wang, Fei; Zhang, Daming; Yi, Yunji

    2015-10-01

    A three dimensional polymer waveguide with taper structure was demonstrated and fabricated by a reliable and effective hybrid lithography. The hybrid lithography consists of lithography to fabricate a polymer waveguide and gray scale lithography to fabricate a polymer taper structure. Laser ablation and shadow aluminum evaporation were designed for gray scale lithography. The length of the gray scale region ranging from 20 to 400 μm could be controlled by the laser power, the ablation speed, and the aluminum thickness. The slope angle was determined by the length of the gray scale region and the thickness of the photoresist. The waveguide taper structure could be transferred to the lower layer by the etching method. The taper structure can be used for integration of the waveguide with different dimensions.

  20. Three-dimensional printing of biological matters

    Directory of Open Access Journals (Sweden)

    Ahmed Munaz

    2016-03-01

    Full Text Available Three-dimensional (3D printing of human tissues and organ has been an exciting research topic in the past three decades. However, existing technological and biological challenges still require a significant amount of research. The present review highlights these challenges and discusses their potential solutions such as mapping and converting a human organ onto a 3D virtual design, synchronizing the virtual design with the printing hardware. Moreover, the paper discusses in details recent advances in formulating bio-inks and challenges in tissue construction with or without scaffold. Next, the paper reviews fusion processes effecting vascular cells and tissues. Finally, the paper deliberates the feasibility of organ printing with state-of-the-art technologies.

  1. Localized shear generates three-dimensional transport

    Science.gov (United States)

    Smith, Lachlan D.; Rudman, Murray; Lester, Daniel R.; Metcalfe, Guy

    2017-04-01

    Understanding the mechanisms that control three-dimensional (3D) fluid transport is central to many processes, including mixing, chemical reaction, and biological activity. Here a novel mechanism for 3D transport is uncovered where fluid particles are kicked between streamlines near a localized shear, which occurs in many flows and materials. This results in 3D transport similar to Resonance Induced Dispersion (RID); however, this new mechanism is more rapid and mutually incompatible with RID. We explore its governing impact with both an abstract 2-action flow and a model fluid flow. We show that transitions from one-dimensional (1D) to two-dimensional (2D) and 2D to 3D transport occur based on the relative magnitudes of streamline jumps in two transverse directions.

  2. GaN three dimensional nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Dmitriev, V.; Irvin, K. [Cree Research, Inc., Durham, NC (United States); Zubrilov, A.; Tsvetkov, D.; Nikolaev, V. [Cree Research EED, St. Petersburg (Russian Federation); Jakobson, M.; Nelson, D.; Sitnikova, A. [A.F. Ioffe Inst., St. Petersburg (Russian Federation)

    1996-11-01

    The authors report on the growth and characterization of three dimensional nanoscale structures of GaN. GaN dots were grown by metal organic chemical vapor deposition (MOCVD) on 6H-SiC substrates. The actual size of the dots measured by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) ranged from {approximately}20 nm to more than 2 {micro}m. The average dot density ranged from 10{sup 7} to 10{sup 9} cm{sup {minus}2}. The single crystal structure of the dots was verified by reflectance high energy electron diffraction (HEED) and TEM. Cathodoluminescence (CL) and photoluminescence (PL) of the dots were studied at various temperatures and excitation levels. The PL and CL edge peak for the GaN dots exhibited a blue shift as compared with edge peak position for continuous GaN layers grown on SiC.

  3. Exact solutions in three-dimensional gravity

    CERN Document Server

    Garcia-Diaz, Alberto A

    2017-01-01

    A self-contained text, systematically presenting the determination and classification of exact solutions in three-dimensional Einstein gravity. This book explores the theoretical framework and general physical and geometrical characteristics of each class of solutions, and includes information on the researchers responsible for their discovery. Beginning with the physical character of the solutions, these are identified and ordered on the basis of their geometrical invariant properties, symmetries, and algebraic classifications, or from the standpoint of their physical nature, for example electrodynamic fields, fluid, scalar field, or dilaton. Consequently, this text serves as a thorough catalogue on 2+1 exact solutions to the Einstein equations coupled to matter and fields, and on vacuum solutions of topologically massive gravity with a cosmological constant. The solutions are also examined from different perspectives, enabling a conceptual bridge between exact solutions of three- and four-dimensional gravit...

  4. Lattice Three-Dimensional Skyrmions Revisited

    CERN Document Server

    Charalampidis, E G; Kevrekidis, P G

    2014-01-01

    In the continuum a skyrmion is a topological nontrivial map between Riemannian manifolds, and a stationary point of a particular energy functional. This paper describes lattice analogues of the aforementioned skyrmions, namely a natural way of using the topological properties of the three-dimensional continuum Skyrme model to achieve topological stability on the lattice. In particular, using fixed point iterations, numerically exact lattice skyrmions are constructed; and their stability under small perturbations is verified by means of linear stability analysis. While stable branches of such solutions are identified, it is also shown that they possess a particularly delicate bifurcation structure, especially so in the vicinity of the continuum limit. The corresponding bifurcation diagram is elucidated and a prescription for selecting the branch asymptoting to the well-known continuum limit is given. Finally, the robustness of the solutions by virtue of direct numerical simulations is corroborated.

  5. Simulation for transthoracic echocardiography of aortic valve

    Science.gov (United States)

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  6. Three-dimensional (3D) analysis of the temporomandibular joint

    DEFF Research Database (Denmark)

    Kitai, N.; Kreiborg, S.; Murakami, S.

    Symposium Orthodontics 2001: Where are We Now? Where are We Going?, three-dimensional analysis, temporomandibular joint......Symposium Orthodontics 2001: Where are We Now? Where are We Going?, three-dimensional analysis, temporomandibular joint...

  7. Springback prediction of three-dimensional variable curvature tube bending

    National Research Council Canada - National Science Library

    Zhang, Shen; Wu, Jianjun

    2016-01-01

    .... The springback prediction of three-dimensional variable curvature bent tube is projected on each discrete osculating and rectifying plane, and then the three-dimensional problem can be transformed into two dimensions...

  8. Three-dimensional echocardiographic imaging of biventricular false tendons mimicking hypertrophic cardiomyopathy.

    Science.gov (United States)

    Kucuk, Ugur; Demirkol, Sait; Celik, Turgay; Balta, Sevket; Yokusoglu, Mehmet

    2012-08-01

    Hypertrophic cardiomyopathy (HCM) is characterized by hypertrophy of the left ventricle, with variable clinical manifestations and morphologic and hemodynamic abnormalities. False tendons (FTs) are discrete, fibromuscular structures of varying length and thickness that tranverse either left and right ventricular cavities. Left and right ventricular FTs were giving a false impression of HCM. Misdiagnosis of HCM can lead to undue anxiety, unnecessary medication, and further evaluation. Three-dimensional (3D) transthoracic echocardiography is additive to conventional two-dimensional imaging in these patients in terms of 3D perspective and anatomically correct examination. We present a 32-year-old male who was misdiagnosed as asymetrical septal hypertrophy.

  9. Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

    Directory of Open Access Journals (Sweden)

    Fatemeh Nabavizadeh

    2012-09-01

    Full Text Available Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc sizes and correlates well with manufacture device size. 3D-TEE will surely prove to increase the technical efficiency and it will become an important tool for the interventionists for periprocedural evaluation of device closures.

  10. Primary and Secondary Three Dimensional Microbatteries

    Science.gov (United States)

    Cirigliano, Nicolas

    Today's MEMS devices are limited more so by the batteries that supply their power than the fabrication methods used to build them. Thick battery electrodes are capable of providing adequate energy, but long and tortuous diffusion pathways lead to low power capabilities. On the other hand, thin film batteries can operate at significant current densities but require large surface areas to supply practical energy. This dilemma can be solved by either developing new high capacity materials or by engineering new battery designs that decouple power and energy. Three dimensional batteries redesign traditional configurations to create nonplanar interfaces between battery components. This can be done by introducing hierarchical structures into the electrode shape. Designs such as these provide a maximum surface area over which chemical reactions can occur. Furthermore, by maintaining small feature sizes, ion diffusion and electronic transport distances can remain minimal. Manipulating these properties ensures fast kinetics that are required for high power situations. Energy density is maximized by layering material in the vertical direction, thus ensuring a minimal footprint area. Three dimensional carbon electrodes are fabricated using basic MEMS techniques. A silicon mold is anisotropically etched to produce channels of a predetermined diameter. The channels are then filled using an infiltration technique with electrode slurry. Once dried, the mold is attached to a current collector and etched using a XeF2 process. Electrodes of varying feature sizes have been fabricated using this method with aspect ratios ranging from 3.5:1 to 7:1. 3D carbon electrodes are shown to obtain capacities over 8 mAh/cm2 at 0.1 mA/cm2, or nearly 700% higher than planar carbon electrodes. When assembled with a planar cathode, the battery cell produced an average discharge capacity of 40 J/cm 2 at a current density of 0.2 mA/cm2. This places the energy density values slightly less than thick

  11. Understanding three-dimensional damage envelopes

    Science.gov (United States)

    Browning, John; Harland, Sophie; Meredith, Philip; Healy, David; Mitchell, Tom

    2017-04-01

    Microcrack damage leading to failure in rocks evolves in response to differential loading. This loading is often visualized in a two-dimensional stress space through the use of Mohr-Coulomb diagrams. The vast majority of experimental studies investigate damage evolution and rock failure using conventional triaxial stress states (σ1 > σ2 = σ3) in which the results can be easily represented in a Mohr-Coulomb plot. However, in nature the stress state is in general truly triaxial (σ1 > σ2 > σ3) and as such comprises a 3D stress state potentially leading to more complexity. By monitoring acoustic wave velocities and acoustic emissions we have shown that damage is generated in multiple orientations depending on the loading directions and hence principal stress directions. Furthermore, crack growth is shown to be a function of differential stress regardless of the mean stress. As such, new cracks can form due to a decrease in the minimum principal stress, which reduces mean stress but increases the differential stress. Although the size of individual cracks is not affected by the intermediate principal stress it has been shown that the σ2 plays a key role in suppressing the total amount of crack growth and concentrates this damage in a single plane. Hence, the differential stress at which rocks fail (i.e. the rock strength) will be significantly increased under true triaxial stress conditions than under the much more commonly applied condition of conventional triaxial stress. Through a series of cyclic loading tests we investigated the Kaiser effect, we show that while individual stress states are important, the stress path by which this stress state is reached is equally important. Whether or not a stress state has been 'visited' before is also vitally important in determining and understanding damage envelopes. Finally, we show that damage evolution can be anisotropic and must be considered as a three-dimensional problem. It is unclear how damage envelopes

  12. [Relationships between right atrial and left ventricular size and function in health subjects. Results from the three-dimensional speckle-tracking echocardiographic MAGYAR-Healthy Study].

    Science.gov (United States)

    Piros, Györgyike Ágnes; Domsik, Péter; Kalapos, Anita; Lengyel, Csaba; Orosz, Andrea; Forster, Tamás; Nemes, Attila

    2015-06-14

    The heart cycle includes systole and diastole when the heart chambers are characterized by a complex motion. The present study was designed to test whether relationships exist between three-dimensional speckle-tracking echocardiography-derived right atrial and routine two-dimensional echocardiography-derived left ventricular volumetric and functional parameters is healthy subjects. The present study comprised 20 healthy volunteers. Complete two-dimensional echocardiography and three-dimensional speckle-tracking echocardiography were perfomed in all cases. Left ventricular ejection fraction showed correlations with systolic and diastolic right atrial volumes and area strain characterzing atrial contraction in diastole. Right atrial volumes respective of cardiac cycle correlated only with left ventricular end-systolic diameter and volume, while similar relationships could not be confirmed with end-diastolic parameters. Relationships could be demonstrated between three-dimensional speckle-tracking echocardiography-derived right atrial and two-dimensional echocardiography-derived left ventricular volumetric and functional parameters in healthy subjects.

  13. Three Dimensional CAPP Technology of Projectile Based on MBD

    Directory of Open Access Journals (Sweden)

    Hongzhi Zhao

    2013-07-01

    Full Text Available This study aims at the research goal of three-dimensional digital process design of projectile, which adopts three-dimensional computer-aided process design technology based on MBD and uses MBD to conduct parametric modeling of projectile that can reduce the input of projectile’s process information and data conversion and produce reasonable, feasible and three-dimensional projectile manufacturing process to realize paperless three-dimensional process design of projectile. The application of three-dimensional computer-assisted process design technology of projectile based on model definition can shorten the design cycle of projectile, thus improving rapid manufacturing capacity of product and reducing cost.

  14. THEORETICAL STUDY OF THREE-DIMENSIONAL NUMERICAL MANIFOLD METHOD

    Institute of Scientific and Technical Information of China (English)

    LUO Shao-ming; ZHANG Xiang-wei; L(U) Wen-ge; JIANG Dong-ru

    2005-01-01

    The three-dimensional numerical manifold method(NMM) is studied on the basis of two-dimensional numerical manifold method. The three-dimensional cover displacement function is studied. The mechanical analysis and Hammer integral method of three-dimensional numerical manifold method are put forward. The stiffness matrix of three-dimensional manifold element is derived and the dissection rules are given. The theoretical system and the numerical realizing method of three-dimensional numerical manifold method are systematically studied. As an example, the cantilever with load on the end is calculated, and the results show that the precision and efficiency are agreeable.

  15. Dynamic 3D echocardiography in virtual reality

    Directory of Open Access Journals (Sweden)

    Simoons Maarten L

    2005-12-01

    Full Text Available Abstract Background This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. Methods Three-dimensional echocardiographic data sets from 2 normal subjects and from 4 patients with a mitral valve pathological condition were included in the study. The three-dimensional data sets were acquired with the Philips Sonos 7500 echo-system and transferred to the BARCO (Barco N.V., Kortrijk, Belgium I-space. Ten independent observers assessed the 6 three-dimensional data sets with and without mitral valve pathology. After 10 minutes' instruction in the I-Space, all of the observers could use the virtual pointer that is necessary to create cut planes in the hologram. Results The 10 independent observers correctly assessed the normal and pathological mitral valve in the holograms (analysis time approximately 10 minutes. Conclusion this report shows that dynamic holographic imaging of three-dimensional echocardiographic data is feasible. However, the applicability and use-fullness of this technology in clinical practice is still limited.

  16. Three dimensional characterization and archiving system

    Energy Technology Data Exchange (ETDEWEB)

    Sebastian, R.L.; Clark, R.; Gallman, P. [Coleman Research Corp., Springfield, VA (United States)] [and others

    1995-10-01

    The Three Dimensional Characterization and Archiving System (3D-ICAS) is being developed as a remote system to perform rapid in situ analysis of hazardous organics and radionuclide contamination on structural materials. Coleman Research and its subcontractors, Thermedics Detection, Inc. (TD) and the University of Idaho (UI) are in the second phase of a three phase program to develop 3D-ICAS to support Decontamination and Decommissioning (D&D) operations. Accurate physical characterization of surfaces and the radioactive and organic is a critical D&D task. Surface characterization includes identification of potentially dangerous inorganic materials, such as asbestos and transite. The 3D-ICAS system robotically conveys a multisensor probe near the surface to be inspected. The sensor position and orientation are monitored and controlled by Coherent laser radar (CLR) tracking. The ICAS fills the need for high speed automated organic analysis by means of gas chromatography-mass spectrometry sensors, and also by radionuclide sensors which combines alpha, beta, and gamma counting.

  17. Clinical significance of three-dimensional sonohysterography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Hye; Lee, Mi Hwa; Lee, Chan; Kim, Jong Wook; Shin, Myung Choel [Pochon Cha University College of Medicine, Pochon (Korea, Republic of)

    1999-12-15

    To evaluate the usefulness of three dimensional sonohysterography (3D SHG) in the evaluation of uterine endometrial and submucosal lesions in comparison with conventional two-dimensional sonohysterography (2D SHG). Our series consisted of 26 patients (mean aged 41 years) who complained of uterine bleeding, menorrhagia, or dysmenorrhea. 2D SHG was performed, and then 3D SHG was done after the volume mode was switched on. Simultaneous display of three perpendicular two-dimensional planes and surface rendering of findings on particular section were obtained. We analyzed whether the endometrium was thickened or not, and the location, size, shape, echogenicity, posterior shadowing, and echogenic rim of the focal lesion. The results were compared with the pathologic findings or MRI. There were submucosal myomas (n=12), intramural myomas (n=2), endometrial polyps (n=7), placental polyp (n=1), and normal endometrial cavities (n=4) on SHG. Nineteen cases were confirmed by pathologic findings or MRI. The results were correlated in 89% (17/19) of the cases. We misdiagnosed 2 cases: focal endometrial hyperplasia and choriocarcinoma were misdiagnosed as endometrial polyp and placental polyp, respectively. Imaging diagnoses were same in the techniques. Comparing with 2D SHG, 3D SHG provided a subjective display of pathologic findings and an additional information about spatial relationship between focal lesion and surroundings.

  18. Globographic visualisation of three dimensional joint angles.

    Science.gov (United States)

    Baker, Richard

    2011-07-07

    Three different methods for describing three dimensional joint angles are commonly used in biomechanics. The joint coordinate system and Cardan/Euler angles are conceptually quite different but are known to represent the same underlying mathematics. More recently the globographic method has been suggested as an alternative and this has proved particularly attractive for the shoulder joint. All three methods can be implemented in a number of ways leading to a choice of angle definitions. Very recently Rab has demonstrated that the globographic method is equivalent to one implementation of the joint coordinate system. This paper presents a rigorous analysis of the three different methods and proves their mathematical equivalence. The well known sequence dependence of Cardan/Euler is presented as equivalent to configuration dependence of the joint coordinate system and orientation dependence of globographic angles. The precise definition of different angle sets can be easily visualised using the globographic method using analogues of longitude, latitude and surface bearings with which most users will already be familiar. The method implicitly requires one axis of the moving segment to be identified as its principal axis and this can be extremely useful in helping define the most appropriate angle set to describe the orientation of any particular joint. Using this technique different angle sets are considered to be most appropriate for different joints and examples of this for the hip, knee, ankle, pelvis and axial skeleton are outlined.

  19. Three dimensional characterization and archiving system

    Energy Technology Data Exchange (ETDEWEB)

    Sebastian, R.L.; Clark, R.; Gallman, P. [and others

    1995-12-01

    The Three Dimensional Characterization and Archiving System (3D-ICAS) is being developed as a remote system to perform rapid in situ analysis of hazardous organics and radionuclide contamination on structural materials. Coleman Research and its subcontractors, Thermedics Detection, Inc. (TD) and the University of Idaho (UI) are in the second phase of a three phase program to develop 3D-ICAS to support Decontamination and Decommissioning (D&D) operations. Accurate physical characterization of surfaces and the radioactive and organic is a critical D&D task. Surface characterization includes identification of potentially dangerous inorganic materials, such as asbestos and transite. Real-time remotely operable characterization instrumentation will significantly advance the analysis capabilities beyond those currently employed. Chemical analysis is a primary area where the characterization process will be improved. Chemical analysis plays a vital role throughout the process of decontamination. Before clean-up operations can begin the site must be characterized with respect to the type and concentration of contaminants, and detailed site mapping must clarify areas of both high and low risk. During remediation activities chemical analysis provides a means to measure progress and to adjust clean-up strategy. Once the clean-up process has been completed the results of chemical analysis will verify that the site is in compliance with federal and local regulations.

  20. Three Dimensional Hydrodynamic Model With Multiquadtree Meshes

    Directory of Open Access Journals (Sweden)

    G. P. Vanegas

    2008-01-01

    Full Text Available This study presents a three dimensional model for the transport of conservative contaminants, which can be used for bodies of water which are affected by winds and/or tides. The model solves the equation of mass transport, based on results obtained using a hydrodynamic model for shallow waters that works in a finite volume scheme and a type of hierarchical grid, called multi-quadtree, which is adaptable to the bathymetry. To solve the vertical coordinates, the coordinate z is transformed into a sigma (σ coordinate, thus allowing the same number of layers in the vertical, regardless of depth. This hydrodynamic model is validated using two cases: a long wave propagated in a channel of variable width and bottom and wind action in a rectangular basin. Finally, the results obtained are presented for a hypothetical single port outfall in the bay of Campeche, México. The model developed here is both quick and easy to use and is efficient when compared with models presented by other authors since it uses adaptable grids which allow detailed solutions to be obtained for areas of interest such as coastlines and the area around an outfall.

  1. Three-dimensionally Perforated Calcium Phosphate Ceramics

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Porous calcium phosphate ceramics were produced by compression molding using a special mold followed by sintering. The porous calcium phosphate ceramics have three-dimensional and penetrated open pores380-400μm in diameter spaced at intervals of 200μm. The layers of the linear penetration pores alternately lay perpendicular to pore direction. The porosity was 59%-65% . The Ca/P molar ratios of the porous calcium phosphate ceramics range from 1.5 to 1.85. A binder containing methyl cellulose was most effective for preparing the powder compact among vinyl acetate, polyvinyl alcohol, starch, stearic acid, methyl cellulose and their mixtures. Stainless steel, polystyrene, nylon and bamboo were used as the long columnar male dies for the penetrated open pores. When polystyrene, nylon and bamboo were used as the long columnar male dies, the dies were burned out during the sintering process. Using stainless steel as the male dies with the removal of the dies before heat treatment resulted in a higher level of densification of the calcium phosphate ceramic.

  2. Three-dimensional survey of paint layer

    Science.gov (United States)

    Pampaloni, Enrico; Bellucci, Roberto; Carcagni, Pierluigi; Casaccia, Antonella; Fontana, Raffaella; Gambino, Maria Chiara; Piccolo, Roberta; Pingi, Paolo; Pezzati, Luca

    2007-07-01

    The quantitative morphological analysis of a painting surface allows to evidence form defects and to study, thus, their influence on the stability of the paint and preparatory layers, as well as of the support. Therefore a three-dimensional survey can be very useful in planning the restoration intervention of a painting. In this work we present the results of the surface analysis carried out on the painting "Ultima Cena" by Giorgio Vasari. This panel painting is severely affected by paint film wrinkling produced as a consequence of the flood that occurred in Florence in 1966. Our analysis, accomplished to quantify the lengthening of the paint layer with respect to the one of the support in order to plan the restoration intervention, was performed on 25 profiles separated each by 10 cm in order to cover the whole painting surface. A data analysis, based on morphological filtering named "Rolling Ball" transformation, was used to evaluate the length difference between the paint layer and the panel support along each profile.

  3. Why Observable Space Is Solely Three Dimensional

    CERN Document Server

    Rabinowitz, Mario

    2015-01-01

    Quantum (and classical) binding energy considerations in n-dimensional space indicate that atoms (and planets) can only exist in three-dimensional space. This is why observable space is solely 3-dimensional. Both a novel Virial theorem analysis, and detailed classical and quantum energy calculations for 3-space circular and elliptical orbits indicate that they have no orbital binding energy in greater than 3-space. The same energy equation also excludes the possibility of atom-like bodies in strictly 1 and 2-dimensions. A prediction is made that in the search for deviations from r^-2 of the gravitational force at sub-millimeter distances such a deviation must occur at < ~ 10^-10 m (or < ~10^-12 m considering muoniom), since atoms would disintegrate if the curled up dimensions of string theory were larger than this. Callender asserts that the often-repeated claim in previous work that stable orbits are possible in only three dimensions is not even remotely established. The binding energy analysis herein ...

  4. Three dimensional modeling of CR propagation

    CERN Document Server

    Gaggero, Daniele; Di Bernardo, Giuseppe; Evoli, Carmelo; Grasso, Dario

    2013-01-01

    We present here a major upgrade of DRAGON, a numerical package that computes the propagation of a wide set of CR species from both astrophysical and exotic origin in the Galaxy in a wide energy range from tens of MeV to tens of TeV. DRAGON takes into account all relevant processes in particular diffusion, convection, reacceleration, fragmentation and energy losses. For the first time, we present a full 3D version of DRAGON with anisotropic position-dependent diffusion. In this version, the propagation is calculated within a 3D cartesian grid and the user is able to implement realistic and structured three dimensional source, gas and regular magnetic field distributions. Moreover, it is possible to specify an arbitrary function of position and rigidity for the diffusion coefficients in the parallel and perpendicular direction to the regular magnetic field of the Galaxy. The code opens many new possibilities in the study of CR physics. In particular, we can study for the first time the impact of the spiral arm ...

  5. Three-Dimensional Printed Graphene Foams.

    Science.gov (United States)

    Sha, Junwei; Li, Yilun; Villegas Salvatierra, Rodrigo; Wang, Tuo; Dong, Pei; Ji, Yongsung; Lee, Seoung-Ki; Zhang, Chenhao; Zhang, Jibo; Smith, Robert H; Ajayan, Pulickel M; Lou, Jun; Zhao, Naiqin; Tour, James M

    2017-07-25

    An automated metal powder three-dimensional (3D) printing method for in situ synthesis of free-standing 3D graphene foams (GFs) was successfully modeled by manually placing a mixture of Ni and sucrose onto a platform and then using a commercial CO2 laser to convert the Ni/sucrose mixture into 3D GFs. The sucrose acted as the solid carbon source for graphene, and the sintered Ni metal acted as the catalyst and template for graphene growth. This simple and efficient method combines powder metallurgy templating with 3D printing techniques and enables direct in situ 3D printing of GFs with no high-temperature furnace or lengthy growth process required. The 3D printed GFs show high-porosity (∼99.3%), low-density (∼0.015g cm(-3)), high-quality, and multilayered graphene features. The GFs have an electrical conductivity of ∼8.7 S cm(-1), a remarkable storage modulus of ∼11 kPa, and a high damping capacity of ∼0.06. These excellent physical properties of 3D printed GFs indicate potential applications in fields requiring rapid design and manufacturing of 3D carbon materials, for example, energy storage devices, damping materials, and sound absorption.

  6. Chaotic Mixing in Three Dimensional Porous Media

    CERN Document Server

    Lester, Daniel R; Borgne, Tanguy Le

    2016-01-01

    Under steady flow conditions, the topological complexity inherent to all random 3D porous media imparts complicated flow and transport dynamics. It has been established that this complexity generates persistent chaotic advection via a three-dimensional (3D) fluid mechanical analogue of the baker's map which rapidly accelerates scalar mixing in the presence of molecular di?usion. Hence pore-scale fluid mixing is governed by the interplay between chaotic advection, molecular di?usion and the broad (power-law) distribution of fluid particle travel times which arise from the non-slip condition at pore walls. To understand and quantify mixing in 3D porous media, we consider these processes in a model 3D open porous network and develop a novel stretching continuous time random walk (CTRW) which provides analytic estimates of pore-scale mixing which compare well with direct numerical simulations. We ?nd that chaotic advection inherent to 3D porous media imparts scalar mixing which scales exponentially with longitudi...

  7. Three dimensional characterization and archiving system

    Energy Technology Data Exchange (ETDEWEB)

    Sebastian, R.L.; Clark, R.; Gallman, P. [and others

    1996-04-01

    The Three Dimensional Characterization and Archiving System (3D-ICAS) is being developed as a remote system to perform rapid in situ analysis of hazardous organics and radionuclide contamination on structural materials. Coleman Research and its subcontractors, Thermedics Detection, Inc. (TD) and the University of Idaho (UI) are in the second phase of a three phase program to develop 3D-ICAS to support Decontamination and Decommissioning (D and D) operations. Accurate physical characterization of surfaces and the radioactive and organic is a critical D and D task. Surface characterization includes identification of potentially dangerous inorganic materials, such as asbestos and transite. Real-time remotely operable characterization instrumentation will significantly advance the analysis capabilities beyond those currently employed. Chemical analysis is a primary area where the characterization process will be improved. The 3D-ICAS system robotically conveys a multisensor probe near the surfaces to be inspected. The sensor position and orientation are monitored and controlled using coherent laser radar (CLR) tracking. The CLR also provides 3D facility maps which establish a 3D world view within which the robotic sensor system can operate.

  8. Three-dimensional Printing in the Intestine.

    Science.gov (United States)

    Wengerter, Brian C; Emre, Gulus; Park, Jea Young; Geibel, John

    2016-08-01

    Intestinal transplantation remains a life-saving option for patients with severe intestinal failure. With the advent of advanced tissue engineering techniques, great strides have been made toward manufacturing replacement tissues and organs, including the intestine, which aim to avoid transplant-related complications. The current paradigm is to seed a biocompatible support material (scaffold) with a desired cell population to generate viable replacement tissue. Although this technique has now been extended by the three-dimensional (3D) printing of geometrically complex scaffolds, the overall approach is hindered by relatively slow turnover and negative effects of residual scaffold material, which affects final clinical outcome. Methods recently developed for scaffold-free 3D bioprinting may overcome such obstacles and should allow for rapid manufacture and deployment of "bioprinted organs." Much work remains before 3D bioprinted tissues can enter clinical use. In this brief review we examine the present state and future perspectives of this nascent technology before full clinical implementation.

  9. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Don; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of); Yoo, Sun Kook; Lee, Kyoung Sang [Dept. of Medical Engineering, College of Medicine, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  10. 实时三维超声心动图评价冠心病患者经皮冠状动脉介入治疗后左心室收缩同步性及功能%Assessment of left ventricular systolic synchrony and systolic function by real-time three-dimensional echocardiography in patients with coronary artery disease after percutaneous coronary intervention

    Institute of Scientific and Technical Information of China (English)

    叶振盛; 欧宓; 陈斌; 郭薇

    2011-01-01

    Objective The left ventricular synchrony and systolic function were assessed in patients with coronary artery disease before and after percutaneous coronary intervention ( PCI ) by real-time three-dimensional echocardiography ( RT-3DE ). Methods A total of 20 healthy volunteers were performed RT-3DE,and twenty patients with coronary artery disease had RT-3DE before PCI. RT-3DE follow-up was performed 1 week after PCI in all patients with coronary artery disease. Full-volume imaging was recorded before and 1 week after PCI and the data was analyzed by Qlab 6. 0 Offline analysis software. A series of global and regional left ventricular volume curves were plotted. The parameters of left ventricular systolic function and regional left ventricular ejection fraction ( rLVEF )were calculated. The parameters of left ventricular synchrony: Tmsv-16-sd、 Tmsv-12-sd、Tmsv-16-dif、Tmsv-12-dif、Tmsv-16-sd%、Tmsv-12-sd%、Tmsv-16-dif%、Tmsv-12-dif% were obtained by offline analysis software. A paired student s t test was used to compare the dates of coronary artery disease before PCI versus follow-up. Independent-samples t test was used to compare the dates between control group and the group of coronary artery disease. Results All the systolic synchrony parameters Tmsv-16-sd, Tmsv-12-sd, Tmsv-16-dif, Tmsv-12-dif, Tmsv-16-sd% , Tmsv-12-sd% , Tmsv-16-dif% and Tmsv-12-dif% were significant larger in patients with coronary artery disease than those of the control group[( 149.2±15.7)ms vs ( 23. 8 ±20. 7 )ms,( 77. 5 ±63. 0 )ms vs ( 15. 6 ±21. 3 ) ms,( 308.0 ±198.8 )ms vs ( 81.9 ±73. 1 )ms, ( 227.2 ±193.8 )ms vs ( 65.6 ± 90.3)ms,( 10. 9 ±6. 3 )% vs ( 2. 6 ±2.4 )% , ( 32. 9 ±21. 9 )% vs ( 11. 2 ± 11.7)%, (24.1 ±22.1 )% vs(6.9 ±8.6)% ,t = -3.714 ~ -6. 588 ,P <0. 05]. After treated with PCI,the Tmsv-16-sd, Tmsv-12-sd, Tmsv-16-dif, Tmsv-12-dif ,Tmsv-16-sd% and Tmsv-16-dif% of coronary artery disease patients were lower than those before PCI[( 58. 8 ±50. 1 )ms vs ( 149

  11. Three-dimensional Spontaneous Magnetic Reconnection

    Science.gov (United States)

    Beresnyak, Andrey

    2017-01-01

    Magnetic reconnection is best known from observations of the Sun where it causes solar flares. Observations estimate the reconnection rate as a small, but non-negligible fraction of the Alfvén speed, so-called fast reconnection. Until recently, the prevailing pictures of reconnection were either of resistivity or plasma microscopic effects, which was contradictory to the observed rates. Alternative pictures were either of reconnection due to the stochasticity of magnetic field lines in turbulence or the tearing instability of the thin current sheet. In this paper we simulate long-term three-dimensional nonlinear evolution of a thin, planar current sheet subject to a fast oblique tearing instability using direct numerical simulations of resistive-viscous magnetohydrodynamics. The late-time evolution resembles generic turbulence with a ‑5/3 power spectrum and scale-dependent anisotropy, so we conclude that the tearing-driven reconnection becomes turbulent reconnection. The turbulence is local in scale, so microscopic diffusivity should not affect large-scale quantities. This is confirmed by convergence of the reconnection rate toward ∼ 0.015{v}{{A}} with increasing Lundquist number. In this spontaneous reconnection, with mean field and without driving, the dissipation rate per unit area also converges to ∼ 0.006ρ {v}{{A}}3, and the dimensionless constants 0.015 and 0.006 are governed only by self-driven nonlinear dynamics of the sheared magnetic field. Remarkably, this also means that a thin current sheet has a universal fluid resistance depending only on its length to width ratio and to {v}{{A}}/c.

  12. Three-dimensional, dynamic meteorology of Titan

    Science.gov (United States)

    Mitchell, J.; Adamkovics, M.; Caballero, R.; Turtle, E. P.; Arias, T.; Sayanagi, K. M.

    2011-12-01

    Titan exhibits an active weather cycle involving methane. Because of low insolation and a stabilizing antigreenhouse effect [McKay et al. 1989], moist convection on Titan cannot be maintained purely through surface evaporative fluxes, indicating that moisture convergence provided by large-scale modes of circulation is important for convective cloud formation [e.g., Mitchell et al. 2006; Barth & Rafkin 2010]. Recent Cassini Imaging Science Subsystem (ISS) images of Titan have revealed large-scale clouds with an interesting array of morphologies and characteristics. Most strikingly, an arrow-shaped cloud oriented eastward was observed at the equator on 27 September 2010 [Turtle et al. 2011a], followed by observations of surface wetting which gradually diminished over several months [Turtle et al. 2011b]. We demonstrate a process for the physical interpretation of individual observed storms and their aggregate effect on surface erosion through a combined analysis of cloud observations and simulations [Mitchell et al. in press]. We show that planetary-scale Kelvin waves naturally arising in a new, three-dimensional version of our Titan general circulation model (GCM) robustly organize convection into chevron-shaped storms at Titan's equator during the current season, as observed. The phasing of this mode with another, much slower one causes a 20-fold increase in precipitation rates over the average, each producing up to several centimeters of precipitation over 1000-km-scale regions, with important implications for observed fluvial features [Langhans et al. 2011]. Our initial results indicate an essential role for planetary-scale atmospheric waves in organizing Titan's methane weather. I will discuss prospects for extending our analysis to other Titan observations.

  13. Measurements using three-dimensional product imaging

    Directory of Open Access Journals (Sweden)

    A. Sioma

    2010-07-01

    Full Text Available This article discusses a method of creating a three-dimensional cast model using vision systems and how that model can be used in thequality assessment process carried out directly on the assembly line. The technology of active vision, consisting in illumination of theobject with a laser beam, was used to create the model. Appropriate configuration of camera position geometry and laser light allows thecollection of height profiles and construction of a 3D model of the product on their basis. The article discusses problems connected with the resolution of the vision system, resolution of the laser beam analysis, and resolution connected with the application of the successive height profiles on sample cast planes. On the basis of the model, measurements allowing assessment of dimension parameters and surface defects of a given cast are presented. On the basis of tests and analyses of such a threedimensional cast model, a range of checks which are possible to conduct using 3D vision systems is indicated.Testing casts using that technology allows rapid assessment of selected parameters. Construction of the product’s model and dimensional assessment take a few seconds, which significantly reduces the duration of checks in the technological process. Depending on the product, a few checks may be carried out simultaneously on the product’s model.The possibility of controlling all outgoing products, and creating and modifying the product parameter control program, makes the solutionhighly flexible, which is confirmed by pilot industrial implementations. The technology will be developed in terms of detection andidentification of surface defects. It is important due to the possibility of using such information for the purposes of selecting technologicalprocess parameters and observing the effect of changes in selected parameters on the cast parameter controlled in a vision system.

  14. Three-dimensional kinematics of hummingbird flight.

    Science.gov (United States)

    Tobalske, Bret W; Warrick, Douglas R; Clark, Christopher J; Powers, Donald R; Hedrick, Tyson L; Hyder, Gabriel A; Biewener, Andrew A

    2007-07-01

    Hummingbirds are specialized for hovering flight, and substantial research has explored this behavior. Forward flight is also important to hummingbirds, but the manner in which they perform forward flight is not well documented. Previous research suggests that hummingbirds increase flight velocity by simultaneously tilting their body angle and stroke-plane angle of the wings, without varying wingbeat frequency and upstroke: downstroke span ratio. We hypothesized that other wing kinematics besides stroke-plane angle would vary in hummingbirds. To test this, we used synchronized high-speed (500 Hz) video cameras and measured the three-dimensional wing and body kinematics of rufous hummingbirds (Selasphorus rufus, 3 g, N=5) as they flew at velocities of 0-12 m s(-1) in a wind tunnel. Consistent with earlier research, the angles of the body and the stroke plane changed with velocity, and the effect of velocity on wingbeat frequency was not significant. However, hummingbirds significantly altered other wing kinematics including chord angle, angle of attack, anatomical stroke-plane angle relative to their body, percent of wingbeat in downstroke, wingbeat amplitude, angular velocity of the wing, wingspan at mid-downstroke, and span ratio of the wingtips and wrists. This variation in bird-centered kinematics led to significant effects of flight velocity on the angle of attack of the wing and the area and angles of the global stroke planes during downstroke and upstroke. We provide new evidence that the paths of the wingtips and wrists change gradually but consistently with velocity, as in other bird species that possess pointed wings. Although hummingbirds flex their wings slightly at the wrist during upstroke, their average wingtip-span ratio of 93% revealed that they have kinematically ;rigid' wings compared with other avian species.

  15. [Three-dimensional reconstruction of heart valves].

    Science.gov (United States)

    Flachskampf, F A; Kühl, H; Franke, A; Frielingsdorf, J; Klues, H; Krebs, W; Hanrath, P

    1995-08-01

    The reconstruction of three-dimensional data sets from two-dimensional echocardiographic images offers several fundamental advantages: 1. more complete data than present in the few standard 2D-view; 2. off-line generation of any desired plane, cut, or perspective after the data set has been acquired; 3. access to quantitative parameters like surface areas (e.g., of valve leaflets or portions of leaflets), volumes, and others, without geometric assumptions. The mitral valve has been the focus of several studies using various techniques of reconstruction of transthoracic or transesophageal images. These studies have shown the mitral annulus to be a non-planar, "saddle-shaped" structure, with an average distance of highest to lowest points of 14 mm in normals. This recognition of mitral annular non-planarity has led to a more stringent echocardiographic definition of mitral valve prolapse. Further studies have shown systolic shrinkage of mitral annular area by about 30% and systolic apico-basal translation of the annulus by approximately 1 cm in normals. In patients with dilated cardiomyopathy, the annulus is flattened, and both cyclic change in annular area and apico-basal translation are significantly reduced. 3D-studies of the left ventricular outflow tract in hypertrophic obstructive cardiomyopathy allow measurement of outflow tract and leaflet surface areas and dynamic spatial visualization of systolic anterior motion of the anterior mitral leaflet. Automated techniques to reconstruct the full grey value data set from a high number of parallel or rotational transesophageal planes allow impressive visualization of normal and diseased mitral and aortic valves or valve prostheses, with special emphasis on generating "surgical" views and perspectives, which cannot be obtained by conventional tomographic imaging.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Airway branching morphogenesis in three dimensional culture

    Directory of Open Access Journals (Sweden)

    Gudjonsson Thorarinn

    2010-11-01

    Full Text Available Abstract Background Lungs develop from the fetal digestive tract where epithelium invades the vascular rich stroma in a process called branching morphogenesis. In organogenesis, endothelial cells have been shown to be important for morphogenesis and the maintenance of organ structure. The aim of this study was to recapitulate human lung morphogenesis in vitro by establishing a three dimensional (3D co-culture model where lung epithelial cells were cultured in endothelial-rich stroma. Methods We used a human bronchial epithelial cell line (VA10 recently developed in our laboratory. This cell line cell line maintains a predominant basal cell phenotype, expressing p63 and other basal markers such as cytokeratin-5 and -14. Here, we cultured VA10 with human umbilical vein endothelial cells (HUVECs, to mimic the close interaction between these cell types during lung development. Morphogenesis and differentiation was monitored by phase contrast microscopy, immunostainings and confocal imaging. Results We found that in co-culture with endothelial cells, the VA10 cells generated bronchioalveolar like structures, suggesting that lung epithelial branching is facilitated by the presence of endothelial cells. The VA10 derived epithelial structures display various complex patterns of branching and show partial alveolar type-II differentiation with pro-Surfactant-C expression. The epithelial origin of the branching VA10 colonies was confirmed by immunostaining. These bronchioalveolar-like structures were polarized with respect to integrin expression at the cell-matrix interface. The endothelial-induced branching was mediated by soluble factors. Furthermore, fibroblast growth factor receptor-2 (FGFR-2 and sprouty-2 were expressed at the growing tips of the branching structures and the branching was inhibited by the FGFR-small molecule inhibitor SU5402. Discussion In this study we show that a human lung epithelial cell line can be induced by endothelial cells to

  17. Three-dimensional nonlinear acoustical holography

    Science.gov (United States)

    Niu, Yaying

    Nearfield Acoustical Holography (NAH) is an acoustic field visualization technique that can be used to reconstruct three-dimensional (3-D) acoustic fields by projecting two-dimensional (2-D) data measured on a hologram surface. However, linear NAH algorithms developed and improved by many researchers can result in significant reconstruction errors when they are applied to reconstruct 3-D acoustic fields that are radiated from a high-level noise source and include significant nonlinear components. Here, planar, nonlinear acoustical holography procedures are developed that can be used to reconstruct 3-D, nonlinear acoustic fields radiated from a high-level noise source based on 2-D acoustic pressure data measured on a hologram surface. The first nonlinear acoustic holography procedure is derived for reconstructing steady-state acoustic pressure fields by applying perturbation and renormalization methods to nonlinear, dissipative, pressure-based Westervelt Wave Equation (WWE). The nonlinear acoustic pressure fields radiated from a high-level pulsating sphere and an infinite-size, vibrating panel are used to validate this procedure. Although the WWE-based algorithm is successfully validated by those two numerical simulations, it still has several limitations: (1) Only the fundamental frequency and its second harmonic nonlinear components can be reconstructed; (2) the application of this algorithm is limited to mono-frequency source cases; (3) the effects of bent wave rays caused by transverse particle velocities are not included; (4) only acoustic pressure fields can be reconstructed. In order to address the limitations of the steady-state, WWE-based procedure, a transient, planar, nonlinear acoustic holography algorithm is developed that can be used to reconstruct 3-D nonlinear acoustic pressure and particle velocity fields. This procedure is based on Kuznetsov Wave Equation (KWE) that is directly solved by using temporal and spatial Fourier Transforms. When compared

  18. Value of three-dimensional speckle-tracking in detecting left ventricular dysfunction in patients with aortic valvular diseases.

    Science.gov (United States)

    Li, Chun-mei; Li, Chen; Bai, Wen-juan; Zhang, Xiao-ling; Tang, Hong; Qing, Zhang; Li, Rao

    2013-11-01

    The aim of this study was to investigate the value of three-dimensional speckle-tracking echocardiography for the detection of subclinical left ventricular dysfunction in patients with aortic valvular disease (AVD). Fifty-nine patients with AVD in New York Heart Association functional class I or II as well as 48 controls were recruited. Patients with AVD were divided further into those with aortic stenosis (AS; n = 34) and those with aortic regurgitation (AR; n = 25). All patients underwent conventional echocardiography and three-dimensional speckle-tracking echocardiography. Analysis of variance showed global longitudinal strain to be compromised in the AR group (-16.9% vs -19.3%, P = .015) and more dramatically decreased in the AS group (-14.3% vs -19.3%, P speckle-tracking echocardiography are useful indices of early-stage heart dysfunction caused by AVD. Longitudinal strain is more vulnerable to pressure overload caused by AS, whereas circumferential strain is more sensitive to volume overload due to AR. Published by Mosby, Inc.

  19. The Three-dimensional Digital Factory for Shipbuilding Technology Research

    Directory of Open Access Journals (Sweden)

    Xu Wei

    2016-01-01

    Full Text Available The three-dimensional digital factory technology research is the hotspot in shipbuilding recently. The three-dimensional digital factory technology not only focus on design the components of the product, but also discuss on the simulation and analyses of the production process.Based on the three-dimensional model, the basic data layer, application control layer and the presentation layer of hierarchical structure are established in the three-dimensional digital factory of shipbuilding in this paper. And the key technologies of three-dimensional digital factory of shipbuilding are analysed. Finally, a case study is applied and the results show that the three-dimensional digital factory will play an important role in the future.

  20. Three-dimensional decomposition method of global atmospheric circulation

    Institute of Scientific and Technical Information of China (English)

    LIU HaiTao; HU ShuJuan; XU Ming; CHOU JiFan

    2008-01-01

    By adopting the idea of three-dimensional Walker, Hadley and Rossby stream functions, the global atmospheric circulation can be considered as the sum of three stream functions from a global perspective. Therefore, a mathematical model of three-dimensional decomposition of global atmospheric circulation is proposed and the existence and uniqueness of the model are proved. Besides, the model includes a numerical method leading to no truncation error in the discrete three-dimensional grid points. Results also show that the three-dimensional stream functions exist and are unique for a given velocity field. The mathematical model shows the generalized form of three-dimensional stream functions equal to the velocity field in representing the features of atmospheric motion. Besides, the vertical velocity calculated through the model can represent the main characteristics of the vertical motion. In sum, the three-dimensional decomposition of atmospheric circulation is convenient for the further investigation of the features of global atmospheric motions.

  1. Three-dimensional carbon nanotube based photovoltaics

    Science.gov (United States)

    Flicker, Jack

    2011-12-01

    Photovoltaic (PV) cells with a three dimensional (3D) morphology are an exciting new research thrust with promise to create cheaper, more efficient solar cells. This work introduces a new type of 3D PV device based on carbon nanotube (CNT) arrays. These arrays are paired with the thin film heterojunction, CdTe/CdS, to form a complete 3D carbon nanotube PV device (3DCNTPV). Marriage of a complicated 3D structure with production methods traditionally used for planar CdTe solar cell is challenging. This work examines the problems associated with processing these types of cells and systematically alters production methods of the semiconductor layers and electrodes to increase the short circuit current (Isc), eliminate parasitic shunts, and increase the open circuit voltage (Voc). The main benefit of 3D solar cell is the ability to utilize multiple photon interactions with the solar cell surface. The three dimensionality allows photons to interact multiple times with the photoactive material, which increases the absorption and the overall power output over what is possible with a two dimensional (2D) morphology. To quantify the increased power output arising from these multiple photon interactions, a new absorption efficiency term, eta3D, is introduced. The theoretical basis behind this new term and how it relates to the absorption efficiency of a planar cell, eta 2D, is derived. A unique model for the average number of multiple photon impingements, Gamma, is proposed based on three categories of 3D morphology: an infinite trench, an enclosed box, and an array of towers. The derivation of eta3D and Gamma for these 3D PV devices gives a complete picture of the enhanced power output over 2D cells based on CNT array height, pitch, radius, and shape. This theory is validated by monte carlo simulations and experiment. This new type of 3D PV devices has been shown to work experimentally. The first 3DCNTPV cells created posses Isc values of 0.085 to 17.872mA/cm2 and Voc values

  2. Intracardiac echocardiography.

    Science.gov (United States)

    Bruce, C J; Friedman, P A

    2002-10-01

    This article describes currently available intracardiac ultrasound (ICE) technology contrasting it with intravascular ultrasound (IVUS) highlighting their differences. Clinical applications in the electrophysiologic and cardiac catheterization laboratory are discussed and current limitations addressed. Intracardiac echocardiography (ICE) is possible because lower frequency transducers (in contrast to higher frequency IVUS devices) have been miniaturized and mounted onto catheters capable of percutaneous insertion into the heart. These lower frequency transducers are capable of enhanced tissue penetration, permitting high-resolution 2D "whole heart" imaging. Also, with the introduction of the newest phased array transducer, Doppler hemodynamic data in addition to high resolution imaging can also be obtained. ICE facilitates electrophysiologic procedures by guiding transseptal catheterization, enabling endocardial anatomy visualization and targeting of arrhythmogenic substrate, ensuring optimal ablation electrode/tissue contact and promptly diagnosing procedural complications. Promising non-electrophysiologic applications include guidance of percutaneous closure of septal defects, percutaneous mitral balloon valvuloplasty and complex cardiac biopsy. Current limitations include monoplanar imaging, narrow field of view, and relatively large size of the catheter. Intra-cardiac imaging is now a clinical tool and has the potential to play an important role in diagnostic and therapeutic interventional procedures. Further refinement and miniaturization of these transducers, through continued technological progress, will make way for primary operator controlled, integrated ultrasound-guided interventional devices.

  3. Three-Dimensional Gear Crack Propagation Studied

    Science.gov (United States)

    Lewicki, David G.

    1999-01-01

    Gears used in current helicopters and turboprops are designed for light weight, high margins of safety, and high reliability. However, unexpected gear failures may occur even with adequate tooth design. To design an extremely safe system, the designer must ask and address the question, "What happens when a failure occurs?" With gear-tooth bending fatigue, tooth or rim fractures may occur. A crack that propagates through a rim will be catastrophic, leading to disengagement of the rotor or propeller, loss of an aircraft, and possible fatalities. This failure mode should be avoided. A crack that propagates through a tooth may or may not be catastrophic, depending on the design and operating conditions. Also, early warning of this failure mode may be possible because of advances in modern diagnostic systems. One concept proposed to address bending fatigue fracture from a safety aspect is a splittooth gear design. The prime objective of this design would be to control crack propagation in a desired direction such that at least half of the tooth would remain operational should a bending failure occur. A study at the NASA Lewis Research Center analytically validated the crack-propagation failsafe characteristics of a split-tooth gear. It used a specially developed three-dimensional crack analysis program that was based on boundary element modeling and principles of linear elastic fracture mechanics. Crack shapes as well as the crack-propagation life were predicted on the basis of the calculated stress intensity factors, mixed-mode crack-propagation trajectory theories, and fatigue crack-growth theories. The preceding figures show the effect of the location of initial cracks on crack propagation. Initial cracks in the fillet of the teeth produced stress intensity factors of greater magnitude (and thus, greater crack growth rates) than those in the root or groove areas of the teeth. Crack growth was simulated in a case study to evaluate crack-propagation paths. Tooth

  4. Three-dimensional simulations of resistance spot welding

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Zhang, Wenqi; Perret, William

    2014-01-01

    This paper draws from the fundamentals of electro-thermo-mechanical coupling to the main aspects of finite element implementation and three-dimensional modelling of resistance welding. A new simulation environment is proposed in order to perform three-dimensional simulations and optimization of r...

  5. Three-dimensional Reciprocal Structures: Morphology, Concepts, Generative Rules

    DEFF Research Database (Denmark)

    Parigi, Dario; Pugnale, Alberto

    2012-01-01

    This paper present seven different three dimensional structures based on the principle of structural reciprocity with superimposition joint and standardized un-notched elements. Such typology could be regarded as being intrinsically three-dimensional because elements sit one of the top of the oth...

  6. Collapse in a forced three-dimensional nonlinear Schrodinger equation

    DEFF Research Database (Denmark)

    Lushnikov, P.M.; Saffman, M.

    2000-01-01

    We derive sufficient conditions for the occurrence of collapse in a forced three-dimensional nonlinear Schrodinger equation without dissipation. Numerical studies continue the results to the case of finite dissipation.......We derive sufficient conditions for the occurrence of collapse in a forced three-dimensional nonlinear Schrodinger equation without dissipation. Numerical studies continue the results to the case of finite dissipation....

  7. Synthetic Spectrum Methods for Three-Dimensional Supernova Models

    CERN Document Server

    Thomas, R C

    2003-01-01

    Current observations stimulate the production of fully three-dimensional explosion models, which in turn motivates three-dimensional spectrum synthesis for supernova atmospheres. We briefly discuss techniques adapted to address the latter problem, and consider some fundamentals of line formation in supernovae without recourse to spherical symmetry. Direct and detailed extensions of the technique are discussed, and future work is outlined.

  8. Semifolded Localized Structures in Three-Dimensional Soliton Systems

    Institute of Scientific and Technical Information of China (English)

    FANG Jian-Ping; ZHENG Chun-Long; CHEN Li-Qun

    2004-01-01

    By means ora Painlevé-Backlund transformation and a multi-linear variable separation approach, abundant localized coherent excitations of the three-dimensional Broer-Kaup-Kupershmidt system with variable coefficients are derived. There are possible phase shifts for the interactions of the three-dimensional novel localized structures discussed in this paper.

  9. Semifolded Localized Structures in Three-Dimensional Soliton Systems

    Institute of Scientific and Technical Information of China (English)

    FANGJian-Ping; ZHENGChun-Long; CHENLi-Qun

    2004-01-01

    By means ofa Painlev6 Backlund transformation and a multi-linear variable separation approach, abundant localized coherent excitations of the three-dimensional Broer Kaup Kupershmidt system with variable coeft~cients are derived. There are possible phase shifts for the interactions of the three-dimensional novel localized structures discussed in this paper.

  10. Computer-Generated, Three-Dimensional Character Animation.

    Science.gov (United States)

    Van Baerle, Susan Lynn

    This master's thesis begins by discussing the differences between 3-D computer animation of solid three-dimensional, or monolithic, objects, and the animation of characters, i.e., collections of movable parts with soft pliable surfaces. Principles from two-dimensional character animation that can be transferred to three-dimensional character…

  11. Three dimensional periodic foundations for base seismic isolation

    Science.gov (United States)

    Yan, Y.; Cheng, Z.; Menq, F.; Mo, Y. L.; Tang, Y.; Shi, Z.

    2015-07-01

    Based on the concept of phononic crystals, periodic foundations made of periodic materials are investigated in this paper. The periodic foundations can provide low frequency band gaps, which cover the main frequency ranges of seismic waves. Therefore, the periodic foundations are able to protect the upper structures during earthquake events. In this paper, the basic theory of three dimensional periodic foundations is studied and the finite element method was used to conduct the sensitivity study. A simplified three-dimensional periodic foundation with a superstructure was tested in the field and the feasibility of three dimensional periodic foundations was proved. The test results showed that the response of the upper structure with the three dimensional periodic foundation was reduced under excitation waves with the main frequency falling in the attenuation zones. The finite element analysis results are consistent with the experimental data, indicating that three dimensional periodic foundations are a feasible way of reducing seismic vibrations.

  12. Virtual three-dimensional blackboard: three-dimensional finger tracking with a single camera.

    Science.gov (United States)

    Wu, Andrew; Hassan-Shafique, Khurram; Shah, Mubarak; da Vitoria Lobo, N

    2004-01-10

    We present a method for three-dimensional (3D) tracking of a human finger from a monocular sequence of images. To recover the third dimension from the two-dimensional images, we use the fact that the motion of the human arm is highly constrained owing to the dependencies between elbow and forearm and the physical constraints on joint angles. We use these anthropometric constraints to derive a 3D trajectory of a gesticulating arm. The system is fully automated and does not require human intervention. The system presented can be used as a visualization tool, as a user-input interface, or as part of some gesture-analysis system in which 3D information is important.

  13. American Society of Echocardiography

    Science.gov (United States)

    American Society of Echocardiography Join Ase Member Portal Log In Membership Member Portal Log In Join ASE Renew Benefits Rates FASE – Fellow of the American Society of Echocardiography Member Referral Program FAQs Initiatives Advocacy ...

  14. Robust three dimensional surface contouring method with digital holography

    Institute of Scientific and Technical Information of China (English)

    YUAN Cao-jin; ZHAI Hong-chen; WANG Xiao-lei; WU Lan

    2006-01-01

    In this paper,a digital holography system with short-coherence light source is used to record a series of holograms of a micro-object. The three dimensional reconstruction is completed by the least-square-polynomial-fitting with a series of two dimensional intensity images which are obtained through holographic reconstruction. This three dimensional reconstruction method can be used to carry out three-dimensional reconstruction of a micro-object with strong laser speckle noise,which can not be obtained from the conventional method.

  15. Cylindrical Three-Dimensional Porous Anodic Alumina Networks

    Directory of Open Access Journals (Sweden)

    Pedro M. Resende

    2016-11-01

    Full Text Available The synthesis of a conformal three-dimensional nanostructure based on porous anodic alumina with transversal nanopores on wires is herein presented. The resulting three-dimensional network exhibits the same nanostructure as that obtained on planar geometries, but with a macroscopic cylindrical geometry. The morphological analysis of the nanostructure revealed the effects of the initial defects on the aluminum surface and the mechanical strains on the integrity of the three-dimensional network. The results evidence the feasibility of obtaining 3D porous anodic alumina on non-planar aluminum substrates.

  16. Three Dimensional Topological Field Theory induced from Generalized Complex Structure

    CERN Document Server

    Ikeda, N

    2004-01-01

    We construct a three-dimensional topological sigma model which is induced from a generalized complex structure on a target generalized complex manifold. This model is constructed from maps from a three-dimensional manifold $X$ to an arbitrary generalized complex manifold $M$. The theory is invariant under the diffeomorphism on the world volume and the $b$-transformation on the generalized complex structure. Moreover the model is manifestly invariant under the mirror symmetry. We derive from this model the Zucchini's two dimensional topological sigma model with a generalized complex structure as a boundary action on $\\partial X$. As a special case, we obtain three dimensional realization of a WZ-Poisson manifold.

  17. Protein conformation in solution by three-dimensional fluorescence spectrometry

    Institute of Scientific and Technical Information of China (English)

    鄢远; 许金钩; 陈国珍

    1996-01-01

    The conformations of bovine serum albumin (USA) and egg albumin (EA) in solution and their conformation changes under different conditions were studied by using three-dimensional fluorescence spectrometry (TDFS) such as three-dimensional fluorescence (TDF) spectra and three-dimensional fluorescence polarization (TDFP) spectra with tryptophan residues in protein molecules as an intrinsic fluorescent probe. The results show that the microenvironment of tryptophan residues of protein molecules in various solutions can be directly indicated and TDFS is an effective tool for studying protein conformation in solution. Meantime, some valuable results were obtained.

  18. DEVELOPMENT OF A HYBRID MODEL FOR THREE-DIMENSIONAL GIS

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    This paper presents a hybrid model for three-dimensional Geographical Information Systems which is an integration of surface- and volume-based models. The Triangulat ed Irregular Network (TIN) and octree models are integrated in this hybrid model. The TIN model works as a surface-based model which mainly serves for surface presentation and visualization. On the other hand, the octree encoding supports volumetric analysis. The designed data structure brings a major advantage in the three-dimensional selective retrieval. This technique increases the efficiency of three-dimensional data operation.

  19. Interactive dynamic three-dimensional scene for the ground-based three-dimensional display

    Science.gov (United States)

    Hou, Peining; Sang, Xinzhu; Guo, Nan; Chen, Duo; Yan, Binbin; Wang, Kuiru; Dou, Wenhua; Xiao, Liquan

    2016-10-01

    Three-dimensional (3D) displays provides valuable tools for many fields, such as scientific experiment, education, information transmission, medical imaging and physical simulation. Ground based 360° 3D display with dynamic and controllable scene can find some special applications, such as design and construction of buildings, aeronautics, military sand table and so on. It can be utilized to evaluate and visualize the dynamic scene of the battlefield, surgical operation and the 3D canvas of art. In order to achieve the ground based 3D display, the public focus plane should be parallel to the camera's imaging planes, and optical axes should be offset to the center of public focus plane in both vertical and horizontal directions. Virtual cameras are used to display 3D dynamic scene with Unity 3D engine. Parameters of virtual cameras for capturing scene are designed and analyzed, and locations of virtual cameras are determined by the observer's eye positions in the observing space world. An interactive dynamic 3D scene for ground based 360° 3D display is demonstrated, which provides high-immersion 3D visualization.

  20. Surgical accuracy of three-dimensional virtual planning

    DEFF Research Database (Denmark)

    Stokbro, Kasper; Aagaard, Esben; Torkov, Peter

    2016-01-01

    This retrospective study evaluated the precision and positional accuracy of different orthognathic procedures following virtual surgical planning in 30 patients. To date, no studies of three-dimensional virtual surgical planning have evaluated the influence of segmentation on positional accuracy ...

  1. Magnetic structure of two- and three-dimensional supramolecular compounds

    Energy Technology Data Exchange (ETDEWEB)

    Decurtins, S.; Schmalle, H.W.; Pellaux, R. [Zurich Univ. (Switzerland); Fischer, P.; Fauth, F. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Ouladdiaf, B. [Institut Max von Laue - Paul Langevin, 75 - Paris (France)

    1997-09-01

    Supramolecular chiral networks of oxalato-bridged transition metals show either two- or three-dimensional structural features. The magnetic structures of such compounds have been investigated by means of elastic neutron powder diffraction. (author) 2 figs., 2 refs.

  2. Direct Linear Transformation Method for Three-Dimensional Cinematography

    Science.gov (United States)

    Shapiro, Robert

    1978-01-01

    The ability of Direct Linear Transformation Method for three-dimensional cinematography to locate points in space was shown to meet the accuracy requirements associated with research on human movement. (JD)

  3. Study on three-dimensional freehand stroke creation

    Directory of Open Access Journals (Sweden)

    Cuixian Xuan

    2015-05-01

    Full Text Available The automotive frames that can be created consciously with three-dimensional freehand strokes are quite important and useful in the early stage of automotive styling. However, all the strokes are drawn on the screen in two-dimensional. This study focuses on the creation of three-dimensional freehand strokes by applying the interpolation algorithm in two orthogonal planes, the projection algorithm and the resultant matrix algorithm. The fitting algorithms of strokes have been developed as the bridges between the traditional two-dimensional sketching and three-dimensional digital modeling. The stylists could use the digital tablet and pen to sketch the frames or outlines of a vehicle in three-dimensional space and then those could be used for establishing the automotive surfaces in any engineering software.

  4. Magnetic structure of two- and three-dimensional supramolecular compounds

    Energy Technology Data Exchange (ETDEWEB)

    Decurtins, S.; Schmalle, H.W.; Pellaux, R. [Zurich Univ. (Switzerland); Fischer, P.; Fauth, F. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Ouladdiaf, B. [Institut Max von Laue - Paul Langevin, 75 - Paris (France)

    1997-09-01

    Supramolecular chiral networks of oxalato-bridged transition metals show either two- or three-dimensional structural features. The magnetic structures of such compounds have been investigated by means of elastic neutron powder diffraction. (author) 2 figs., 2 refs.

  5. Three-Dimensional Measurement and Reconstruction of Fabric Drape Shape

    Institute of Scientific and Technical Information of China (English)

    SHEN Yi; YIN Hong-yuan; LIU Xuan-mu

    2007-01-01

    This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics.

  6. Standalone visualization tool for three-dimensional DRAGON geometrical models

    Energy Technology Data Exchange (ETDEWEB)

    Lukomski, A.; McIntee, B.; Moule, D.; Nichita, E. [Faculty of Energy Systems and Nuclear Science, Univ. of Ontario Inst. of Tech., Oshawa, Ontario (Canada)

    2008-07-01

    DRAGON is a neutron transport and depletion code able to solve one-, two- and three-dimensional problems. To date DRAGON provides two visualization modules, able to represent respectively two- and three-dimensional geometries. The two-dimensional visualization module generates a postscript file, while the three dimensional visualization module generates a MATLAB M-file with instructions for drawing the tracks in the DRAGON TRACKING data structure, which implicitly provide a representation of the geometry. The current work introduces a new, standalone, tool based on the open-source Visualization Toolkit (VTK) software package which allows the visualization of three-dimensional geometrical models by reading the DRAGON GEOMETRY data structure and generating an axonometric image which can be manipulated interactively by the user. (author)

  7. Three-dimensional reconstruction of functional brain images

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Masato; Shoji, Kazuhiko; Kojima, Hisayoshi; Hirano, Shigeru; Naito, Yasushi; Honjo, Iwao [Kyoto Univ. (Japan)

    1999-08-01

    We consider PET (positron emission tomography) measurement with SPM (Statistical Parametric Mapping) analysis to be one of the most useful methods to identify activated areas of the brain involved in language processing. SPM is an effective analytical method that detects markedly activated areas over the whole brain. However, with the conventional presentations of these functional brain images, such as horizontal slices, three directional projection, or brain surface coloring, makes understanding and interpreting the positional relationships among various brain areas difficult. Therefore, we developed three-dimensionally reconstructed images from these functional brain images to improve the interpretation. The subjects were 12 normal volunteers. The following three types of images were constructed: routine images by SPM, three-dimensional static images, and three-dimensional dynamic images, after PET images were analyzed by SPM during daily dialog listening. The creation of images of both the three-dimensional static and dynamic types employed the volume rendering method by VTK (The Visualization Toolkit). Since the functional brain images did not include original brain images, we synthesized SPM and MRI brain images by self-made C++ programs. The three-dimensional dynamic images were made by sequencing static images with available software. Images of both the three-dimensional static and dynamic types were processed by a personal computer system. Our newly created images showed clearer positional relationships among activated brain areas compared to the conventional method. To date, functional brain images have been employed in fields such as neurology or neurosurgery, however, these images may be useful even in the field of otorhinolaryngology, to assess hearing and speech. Exact three-dimensional images based on functional brain images are important for exact and intuitive interpretation, and may lead to new developments in brain science. Currently, the surface

  8. Stability of compressible three-dimensional boundary-layer flows

    Science.gov (United States)

    Reed, H. L.; Nayfeh, A. H.

    1982-01-01

    For compressible three-dimensional flow, the method of multiple scales to formulate the three-dimensional stability problem and determine the partial-differential equations governing variations of the amplitude and complex wavenumbers is used. A method for following one specific wave along its trajectory to ascertain the characteristics of the most unstable disturbance is proposed. Numerical results using the flow over the X-21 wing as calculated from the Kaups-Cebeci code will be presented.

  9. Alignment-free three-dimensional optical metamaterials.

    Science.gov (United States)

    Zhao, Yang; Shi, Jinwei; Sun, Liuyang; Li, Xiaoqin; Alù, Andrea

    2014-03-05

    Three-dimensional optical metamaterials based on multilayers typically rely on critical vertical alignment to achieve the desired functionality. Here the conditions under which three-dimensional metamaterials with different functionalities may be realized without constraints on alignment are analyzed and demonstrated experimentally. This study demonstrates that the release of alignment constraints for multilayered metamaterials is allowed, while their anomalous interaction with light is preserved. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Three-dimensional visualization and animation for power systems analysis

    Energy Technology Data Exchange (ETDEWEB)

    Milano, Federico [Department of Electrical Engineering of the University of Castilla-La Mancha, 13071, Ciudad Real (Spain)

    2009-12-15

    This paper describes a novel approach for three-dimensional visualization and animation of power systems analyses. The paper demonstrates that three-dimensional visualization of power systems can be used for teaching and can help in easily understanding complex concepts. The solutions of power flow analysis, continuation power flow, optimal power flow and time domain simulations are used for illustrating the proposed technique. The paper presents a variety of examples, particularly oriented to education and practitioner training. Conclusions are duly drawn. (author)

  11. Three-dimensional network of Drosophila brain hemisphere

    OpenAIRE

    Mizutani, Ryuta; Saiga, Rino; Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2016-01-01

    The first step to understanding brain function is to determine the brain's network structure. We report a three-dimensional analysis of the brain network of the fruit fly Drosophila melanogaster by synchrotron-radiation tomographic microscopy. A skeletonized wire model of the left half of the brain network was built by tracing the three-dimensional distribution of X-ray absorption coefficients. The obtained models of neuronal processes were classified into groups on the basis of their three-d...

  12. Three-dimensional study of the multi-cavity FEL

    Energy Technology Data Exchange (ETDEWEB)

    Krishnagopal, S.; Kumar, V. [Centre for Advanced Technology, Indore (India)

    1995-12-31

    The Multi-Cavity Free-Electron Laser has been proposed earlier, as a new configuration to obtain short, intense pulses of radiation, the key idea being to pre-bunch the electron beam in a number of very short cavities. Those studies were one-dimensional. Here we use three-dimensional simulations to study the viability of this concept when three-dimensional effects are included, particularly with regard to the transverse modes of the optical beam.

  13. Uniform Deterministic Discrete Method for Three Dimensional Systems

    Institute of Scientific and Technical Information of China (English)

    1997-01-01

    For radiative direct exchange areas in three dimensional system,the Uniform Deterministic Discrete Method(UDDM) was adopted.The spherical surface dividing method for sending area element and the regular icosahedron for sending volume element can meet with the direct exchange area computation of any kind of zone pairs.The numerical examples of direct exchange area in three dimensional system with nonhomogeneous attenuation coefficients indicated that the UDDM can give very high numercal accuracy.

  14. Three-dimensional decomposition method of global atmospheric circulation

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    By adopting the idea of three-dimensional Walker, Hadley and Rossby stream functions, the global atmospheric circulation can be considered as the sum of three stream functions from a global per- spective. Therefore, a mathematical model of three-dimensional decomposition of global atmospheric circulation is proposed and the existence and uniqueness of the model are proved. Besides, the model includes a numerical method leading to no truncation error in the discrete three-dimensional grid points. Results also show that the three-dimensional stream functions exist and are unique for a given velocity field. The mathematical model shows the generalized form of three-dimensional stream func- tions equal to the velocity field in representing the features of atmospheric motion. Besides, the vertical velocity calculated through the model can represent the main characteristics of the vertical motion. In sum, the three-dimensional decomposition of atmospheric circulation is convenient for the further in- vestigation of the features of global atmospheric motions.

  15. Ordered three-dimensional interconnected nanoarchitectures in anodic porous alumina

    Science.gov (United States)

    Martín, Jaime; Martín-González, Marisol; Fernández, Jose Francisco; Caballero-Calero, Olga

    2014-01-01

    Three-dimensional nanostructures combine properties of nanoscale materials with the advantages of being macro-sized pieces when the time comes to manipulate, measure their properties, or make a device. However, the amount of compounds with the ability to self-organize in ordered three-dimensional nanostructures is limited. Therefore, template-based fabrication strategies become the key approach towards three-dimensional nanostructures. Here we report the simple fabrication of a template based on anodic aluminum oxide, having a well-defined, ordered, tunable, homogeneous 3D nanotubular network in the sub 100 nm range. The three-dimensional templates are then employed to achieve three-dimensional, ordered nanowire-networks in Bi2Te3 and polystyrene. Lastly, we demonstrate the photonic crystal behavior of both the template and the polystyrene three-dimensional nanostructure. Our approach may establish the foundations for future high-throughput, cheap, photonic materials and devices made of simple commodity plastics, metals, and semiconductors. PMID:25342247

  16. Method for aortic wall strain measurement with three-dimensional ultrasound speckle tracking and fitted finite element analysis.

    Science.gov (United States)

    Karatolios, Konstantinos; Wittek, Andreas; Nwe, Thet Htar; Bihari, Peter; Shelke, Amit; Josef, Dennis; Schmitz-Rixen, Thomas; Geks, Josef; Maisch, Bernhard; Blase, Christopher; Moosdorf, Rainer; Vogt, Sebastian

    2013-11-01

    Aortic wall strains are indicators of biomechanical changes of the aorta due to aging or progressing pathologies such as aortic aneurysm. We investigated the potential of time-resolved three-dimensional ultrasonography coupled with speckle-tracking algorithms and finite element analysis as a novel method for noninvasive in vivo assessment of aortic wall strain. Three-dimensional volume datasets of 6 subjects without cardiovascular risk factors and 2 abdominal aortic aneurysms were acquired with a commercial real time three-dimensional echocardiography system. Longitudinal and circumferential strains were computed offline with high spatial resolution using a customized commercial speckle-tracking software and finite element analysis. Indices for spatial heterogeneity and systolic dyssynchrony were determined for healthy abdominal aortas and abdominal aneurysms. All examined aortic wall segments exhibited considerable heterogenous in-plane strain distributions. Higher spatial resolution of strain imaging resulted in the detection of significantly higher local peak strains (p ≤ 0.01). In comparison with healthy abdominal aortas, aneurysms showed reduced mean strains and increased spatial heterogeneity and more pronounced temporal dyssynchrony as well as delayed systole. Three-dimensional ultrasound speckle tracking enables the analysis of spatially highly resolved strain fields of the aortic wall and offers the potential to detect local aortic wall motion deformations and abnormalities. These data allow the definition of new indices by which the different biomechanical properties of healthy aortas and aortic aneurysms can be characterized. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Left ventricular mechanics in isolated mild mitral stenosis: a three dimensional speckle tracking study.

    Science.gov (United States)

    Poyraz, Esra; Öz, Tuğba Kemaloğlu; Zeren, Gönül; Güvenç, Tolga Sinan; Dönmez, Cevdet; Can, Fatma; Güvenç, Rengin Çetin; Dayı, Şennur Ünal

    2017-09-01

    In a fraction of patients with mild mitral stenosis, left ventricular systolic function deteriorates despite the lack of hemodynamic load imposed by the dysfunctioning valve. Neither the predisposing factors nor the earlier changes in left ventricular contractility were understood adequately. In the present study we aimed to evaluate left ventricular mechanics using three-dimensional (3D) speckle tracking echocardiography. A total of 31 patients with mild rheumatic mitral stenosis and 27 healthy controls were enrolled to the study. All subjects included to the study underwent echocardiographic examination to collect data for two- and three-dimensional speckle-tracking based stain, twist angle and torsion measurements. Data was analyzed offline with a echocardiographic data analysis software. Patients with rheumatic mild MS had lower global longitudinal (p < 0.001) circumferential (p = 0.02) and radial (p < 0.01) strain compared to controls, despite ejection fraction was similar for both groups [(p = 0.45) for three dimensional and (p = 0.37) for two dimensional measurement]. While the twist angle was not significantly different between groups (p = 0.11), left ventricular torsion was significantly higher in mitral stenosis group (p = 0.03). All strain values had a weak but significant positive correlation with mitral valve area measured with planimetry. Subclinical left ventricular systolic dysfunction develops at an early stage in rheumatic mitral stenosis. Further work is needed to elucidate patients at risk for developing overt systolic dysfunction.

  18. Three-dimensional magnetospheric equilibrium with isotropic pressure

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, C.Z.

    1995-05-01

    In the absence of the toroidal flux, two coupled quasi two-dimensional elliptic equilibrium equations have been derived to describe self-consistent three-dimensional static magnetospheric equilibria with isotropic pressure in an optimal ({Psi},{alpha},{chi}) flux coordinate system, where {Psi} is the magnetic flux function, {chi} is a generalized poloidal angle, {alpha} is the toroidal angle, {alpha} = {phi} {minus} {delta}({Psi},{phi},{chi}) is the toroidal angle, {delta}({Psi},{phi},{chi}) is periodic in {phi}, and the magnetic field is represented as {rvec B} = {del}{Psi} {times} {del}{alpha}. A three-dimensional magnetospheric equilibrium code, the MAG-3D code, has been developed by employing an iterative metric method. The main difference between the three-dimensional and the two-dimensional axisymmetric solutions is that the field-aligned current and the toroidal magnetic field are finite for the three-dimensional case, but vanish for the two-dimensional axisymmetric case. With the same boundary flux surface shape, the two-dimensional axisymmetric results are similar to the three-dimensional magnetosphere at each local time cross section.

  19. Biodynamic profiling of three-dimensional tissue growth techniques

    Science.gov (United States)

    Sun, Hao; Merrill, Dan; Turek, John; Nolte, David

    2016-03-01

    Three-dimensional tissue culture presents a more biologically relevant environment in which to perform drug development than conventional two-dimensional cell culture. However, obtaining high-content information from inside three dimensional tissue has presented an obstacle to rapid adoption of 3D tissue culture for pharmaceutical applications. Biodynamic imaging is a high-content three-dimensional optical imaging technology based on low-coherence interferometry and digital holography that uses intracellular dynamics as high-content image contrast. In this paper, we use biodynamic imaging to compare pharmaceutical responses to Taxol of three-dimensional multicellular spheroids grown by three different growth techniques: rotating bioreactor, hanging-drop and plate-grown spheroids. The three growth techniques have systematic variations among tissue cohesiveness and intracellular activity and consequently display different pharmacodynamics under identical drug dose conditions. The in vitro tissue cultures are also compared to ex vivo living biopsies. These results demonstrate that three-dimensional tissue cultures are not equivalent, and that drug-response studies must take into account the growth method.

  20. Coupled particle dispersion by three-dimensional vortex structures

    Energy Technology Data Exchange (ETDEWEB)

    Troutt, T.R.; Chung, J.N.; Crowe, C.T.

    1996-12-31

    The primary objective of this research program is to obtain understanding concerning the role of three-dimensional vortex structures in the dispersion of particles and droplets in free shear flows. This research program builds on previous studies which focused on the nature of particle dispersion in large scale quasi two-dimensional vortex structures. This investigation employs time dependent experimental and numerical techniques to provide information concerning the particulate dispersion produced by three dimensional vortex structures in free shear layers. The free shear flows investigated include modified plane mixing layers, and modified plane wakes. The modifications to these flows involve slight perturbations to the initiation boundary conditions such that three-dimensional vortex structures are rapidly generated by the experimental and numerical flow fields. Recent results support the importance of these vortex structures in the particle dispersion process.

  1. Hydrofocusing Bioreactor for Three-Dimensional Cell Culture

    Science.gov (United States)

    Gonda, Steve R.; Spaulding, Glenn F.; Tsao, Yow-Min D.; Flechsig, Scott; Jones, Leslie; Soehnge, Holly

    2003-01-01

    The hydrodynamic focusing bioreactor (HFB) is a bioreactor system designed for three-dimensional cell culture and tissue-engineering investigations on orbiting spacecraft and in laboratories on Earth. The HFB offers a unique hydrofocusing capability that enables the creation of a low-shear culture environment simultaneously with the "herding" of suspended cells, tissue assemblies, and air bubbles. Under development for use in the Biotechnology Facility on the International Space Station, the HFB has successfully grown large three-dimensional, tissuelike assemblies from anchorage-dependent cells and grown suspension hybridoma cells to high densities. The HFB, based on the principle of hydrodynamic focusing, provides the capability to control the movement of air bubbles and removes them from the bioreactor without degrading the low-shear culture environment or the suspended three-dimensional tissue assemblies. The HFB also provides unparalleled control over the locations of cells and tissues within its bioreactor vessel during operation and sampling.

  2. Computational methods for three-dimensional microscopy reconstruction

    CERN Document Server

    Frank, Joachim

    2014-01-01

    Approaches to the recovery of three-dimensional information on a biological object, which are often formulated or implemented initially in an intuitive way, are concisely described here based on physical models of the object and the image-formation process. Both three-dimensional electron microscopy and X-ray tomography can be captured in the same mathematical framework, leading to closely-related computational approaches, but the methodologies differ in detail and hence pose different challenges. The editors of this volume, Gabor T. Herman and Joachim Frank, are experts in the respective methodologies and present research at the forefront of biological imaging and structural biology.   Computational Methods for Three-Dimensional Microscopy Reconstruction will serve as a useful resource for scholars interested in the development of computational methods for structural biology and cell biology, particularly in the area of 3D imaging and modeling.

  3. Radiation hardness of three-dimensional polycrystalline diamond detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lagomarsino, Stefano, E-mail: lagomarsino@fi.infn.it; Sciortino, Silvio [National Institute of Nuclear Physics (INFN), Via B. Rossi, 1-3, 50019 Sesto Fiorentino (Italy); Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Bellini, Marco [European Laboratory for Non-Linear Spectroscopy, Via Nello Carrara 1, 50019 Sesto Fiorentino (Italy); Istituto Nazionale di Ottica (INO-CNR), Largo Enrico Fermi 6, 50125 Firenze (Italy); Corsi, Chiara [Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); European Laboratory for Non-Linear Spectroscopy, Via Nello Carrara 1, 50019 Sesto Fiorentino (Italy); Cindro, Vladimir [Jozef Stefan Institute, Jamova cesta 39, 1000 Ljubljana (Slovenia); Kanxheri, Keida; Servoli, Leonello [National Institute of Nuclear Physics (INFN), Via A. Pascoli, 06123 Perugia (Italy); Department of Physics, University of Perugia, Via A. Pascoli, 06123 Perugia (Italy); Morozzi, Arianna [Department of Engineering, University of Perugia, Via G. Duranti 93, 06125 Perugia (Italy); Passeri, Daniele [National Institute of Nuclear Physics (INFN), Via A. Pascoli, 06123 Perugia (Italy); Department of Engineering, University of Perugia, Via G. Duranti 93, 06125 Perugia (Italy); Schmidt, Christian J. [GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt (Germany)

    2015-05-11

    The three-dimensional concept in particle detection is based on the fabrication of columnar electrodes perpendicular to the surface of a solid state radiation sensor. It permits to improve the radiation resistance characteristics of a material by lowering the necessary bias voltage and shortening the charge carrier path inside the material. If applied to a long-recognized exceptionally radiation-hard material like diamond, this concept promises to pave the way to the realization of detectors of unprecedented performances. We fabricated conventional and three-dimensional polycrystalline diamond detectors, and tested them before and after neutron damage up to 1.2 ×10{sup 16 }cm{sup −2}, 1 MeV-equivalent neutron fluence. We found that the signal collected by the three-dimensional detectors is up to three times higher than that of the conventional planar ones, at the highest neutron damage ever experimented.

  4. Three-dimensional network of Drosophila brain hemisphere

    CERN Document Server

    Mizutani, Ryuta; Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio

    2016-01-01

    The first step to understanding brain function is to determine the brain's network structure. We report a three-dimensional analysis of the brain network of the fruit fly Drosophila melanogaster by synchrotron-radiation tomographic microscopy. A skeletonized wire model of the left half of the brain network was built by tracing the three-dimensional distribution of X-ray absorption coefficients. The obtained models of neuronal processes were classified into groups on the basis of their three-dimensional structures. These classified groups correspond to neuronal tracts that send long-range projections or repeated structures of the optic lobe. The skeletonized model is also composed of neuronal processes that could not be classified into the groups. The distribution of these unclassified structures correlates with the distribution of contacts between neuronal processes. This suggests that neurons that cannot be classified into typical structures should play important roles in brain functions. The quantitative de...

  5. Three-dimensional microtomographic imaging of human brain cortex

    CERN Document Server

    Mizutania, Ryuta; Uesugi, Kentaro; Ohyama, Masami; Takekoshi, Susumu; Osamura, R Yoshiyuki; Suzuki, Yoshio

    2016-01-01

    This paper describes an x-ray microtomographic technique for imaging the three-dimensional structure of the human cerebral cortex. Neurons in the brain constitute a neural circuit as a three-dimensional network. The brain tissue is composed of light elements that give little contrast in a hard x-ray transmission image. The contrast was enhanced by staining neural cells with metal compounds. The obtained structure revealed the microarchitecture of the gray and white matter regions of the frontal cortex, which is responsible for the higher brain functions.

  6. Three-dimensional flow and turbulence structure in electrostatic precipitator

    DEFF Research Database (Denmark)

    Ullum, Thorvald Uhrskov; Larsen, Poul Scheel; Özcan, Oktay

    2002-01-01

    Stereo PIV is employed to study the three-dimensional velocity and turbulence fields in a laboratory model of a negative corona, barbed-wire, smooth-plate, electrostatic precipitator (figure 1). The study is focused on determining the parametric effects of axial development, mean current density Jm...... and bulk velocity U0 on secondary flows and turbulence levels and structures due to the action of the three-dimensional electrostatic field on the charged gas. At constant bulk velocity (U0 = 1 m/s) and current density (Jm = 0.4 mA/m2), secondary flows in the form of rolls of axial vorticity with swirl...

  7. A class of auxetic three-dimensional lattices

    CERN Document Server

    Cabras, Luigi

    2015-01-01

    We propose a class of auxetic three-dimensional lattice structures. The elastic microstructure can be designed in order to have omni-directional Poisson's ratio arbitrarily close to the stability limit -1. The cubic behavior of the periodic system has been fully characterized; the minumum and maximum Poisson's ratio and the associated principal directions are given as a function of the microstructural parameters. The initial microstructure is then modified into a body centered-cubic system that can achieve a Poisson's ratio lower than -1 and that can also behave as an isotropic three-dimensional auxetic structure.

  8. Three dimensional super-resolution in metamaterial slab lenses

    CERN Document Server

    Mesa, F; Freire, M; Baena, J D

    2005-01-01

    This letter presents a theoretical and experimental study on the viability of obtaining three dimensional super-resolution (i.e. resolution overcoming the diffraction limit for all directions in space) by means of metamaterial slab lenses. Although the source field cannot be actually reproduced at the back side of the lens with super-resolution in all space directions, the matching capabilities of metamaterial slabs does make it possible the detection of images with three-dimensional super-resolution. This imaging takes place because of the coupling between the evanescent space harmonic components of the field generated at both the source and the detector.

  9. A system of three-dimensional complex variables

    Science.gov (United States)

    Martin, E. Dale

    1986-01-01

    Some results of a new theory of multidimensional complex variables are reported, including analytic functions of a three-dimensional (3-D) complex variable. Three-dimensional complex numbers are defined, including vector properties and rules of multiplication. The necessary conditions for a function of a 3-D variable to be analytic are given and shown to be analogous to the 2-D Cauchy-Riemann equations. A simple example also demonstrates the analogy between the newly defined 3-D complex velocity and 3-D complex potential and the corresponding ordinary complex velocity and complex potential in two dimensions.

  10. Structure of turbulence in three-dimensional boundary layers

    Science.gov (United States)

    Subramanian, Chelakara S.

    1993-01-01

    This report provides an overview of the three dimensional turbulent boundary layer concepts and of the currently available experimental information for their turbulence modeling. It is found that more reliable turbulence data, especially of the Reynolds stress transport terms, is needed to improve the existing modeling capabilities. An experiment is proposed to study the three dimensional boundary layer formed by a 'sink flow' in a fully developed two dimensional turbulent boundary layer. Also, the mean and turbulence field measurement procedure using a three component laser Doppler velocimeter is described.

  11. Urologic applications of multiplanar and three-dimensional computed tomography.

    Science.gov (United States)

    Olson, M C; Posniak, H V

    1995-01-01

    The introduction of helical computed tomography (CT) has resulted in improved quality of multiplanar reformations and three-dimensional reconstructions in the chest and abdomen and has made CT angiography a clinical reality. These imaging techniques are useful for evaluating the urinary tract, adding a new dimension to its display, resulting in improved diagnosis of renal and perirenal disease. This article reviews the indications and techniques utilized for multiplanar and three-dimensional CT for urology. The advantages and limitations are discussed, and normal and pathologic findings in the urinary tract illustrated.

  12. Gas-Kinetic BGK Scheme for Three Dimensional Magnetohydrodynamics

    Institute of Scientific and Technical Information of China (English)

    Huazhong

    2010-01-01

    The gas-kinetic theory based flux splitting method has been successfully proposed for solving one- and two-dimensional ideal magnetohydrodynamics by Xu et al.[J. Comput. Phys., 1999; 2000], respectively. This paper extends the kinetic method to solve three-dimensional ideal magnetohydrodynamics equations, where an adaptive parameter η is used to control the numerical dissipation in the flux splitting method.Several numerical examples are given to demonstrate that the proposed method can achieve high numerical accuracy and resolve strong discontinuous waves in three dimensional ideal MHD problems.

  13. Three Dimensional Imaging with Multiple Wavelength Speckle Interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Bernacki, Bruce E.; Cannon, Bret D.; Schiffern, John T.; Mendoza, Albert

    2014-05-28

    We present the design, modeling, construction, and results of a three-dimensional imager based upon multiple-wavelength speckle interferometry. A surface under test is illuminated with tunable laser light in a Michelson interferometer configuration while a speckled image is acquired at each laser frequency step. The resulting hypercube is Fourier transformed in the frequency dimension and the beat frequencies that result map the relative offsets of surface features. Synthetic wavelengths resulting from the laser tuning can probe features ranging from 18 microns to hundreds of millimeters. Three dimensional images will be presented along with modeling results.

  14. Fabrication and characterization of three-dimensional biomimetic chiral composites.

    Science.gov (United States)

    Turner, Mark D; Schröder-Turk, Gerd E; Gu, Min

    2011-05-09

    Here we show the fabrication and characterization of a novel class of biomimetic photonic chiral composites inspired by a recent finding in butterfly wing-scales. These three-dimensional networks have cubic symmetry, are fully interconnected, have robust mechanical strength and possess chirality which can be controlled through the composition of multiple chiral networks, providing an excellent platform for developing novel chiral materials. Using direct laser writing we have fabricated different types of chiral composites that can be engineered to form novel photonic devices. We experimentally show strong circular dichroism and compare with numerical simulations to illustrate the high quality of these three-dimensional photonic structures.

  15. Symmetries and defects in three-dimensional topological field theory

    CERN Document Server

    Fuchs, Jurgen

    2015-01-01

    Boundary conditions and defects of any codimension are natural parts of any quantum field theory. Surface defects in three-dimensional topological field theories of Turaev-Reshetikhin type have applications to two-dimensional conformal field theories, in solid state physics and in quantum computing. We explain an obstruction to the existence of surface defects that takes values in a Witt group. We then turn to surface defects in Dijkgraaf-Witten theories and their construction in terms of relative bundles; this allows one to exhibit Brauer-Picard groups as symmetry groups of three-dimensional topological field theories.

  16. Data Visualization in Physics II: VRML and Java for three-dimensional imaging and fully three-dimensional movies

    Science.gov (United States)

    Fenton, Flavio H.; Evans, Steven J.; Hastings, Harold M.; Cherry, Elizabeth M.

    2006-03-01

    Presentation and analysis of large three-dimensional data sets is in general hard to do using only two-dimensional figures and plots. In this talk, we will demonstrate techniques for illustrating static and dynamic three-dimensional objects and data using Virtual Reality Modeling Language (VRML) as well as Java. The advantage of these two languages is that they are platform-independent, which allows for easy sharing of data and visualizations. In addition, manipulation of data is relatively easy as rotation, translation and zooming can be done in real- time for static objects as well as for data and objects that vary and deform in time. Examples of fully three-dimensional movies will be shown, including dendritic growth and propagation of electrical waves in cardiac tissue. In addition, we will show how to include VRML and Java viewers in PowerPoint for easy presentation of results in classes and seminars.

  17. Approaching the Sequential and Three-Dimensional Organization of Genomes

    NARCIS (Netherlands)

    T.A. Knoch (Tobias)

    2006-01-01

    textabstractGenomes are one of the major foundations of life due to their role in information storage, process regulation and evolution. To achieve a deeper unterstanding of the human genome the three-dimensional organization of the human cell nucleus, the structural-, scaling- and dynamic prope

  18. Vacuum polarization around a three-dimensional black hole

    CERN Document Server

    Shiraishi, Kiyoshi

    2015-01-01

    We calculate the Euclidean propagator for a conformally coupled massless scalar field in the background of the three-dimensional black hole. The expectation value $\\langle\\varphi^2\\rangle$ in the Hartle-Hawking state is obtained in the spacetime.

  19. Generation of a Desired Three-Dimensional Electromagnetic Field

    DEFF Research Database (Denmark)

    2005-01-01

    The present invention relates to a method and a system for synthesizing a prescribed three-dimensional electromagnetic field based on generalized phase contrast imaging. Such a method and apparatus may be utilized in advanced optical micro and nano-manipulation, such as by provision of a multiple...

  20. Three-dimensional reconstruction of the otosclerotic focus

    DEFF Research Database (Denmark)

    Bloch, Sune Land; Sørensen, Mads Sølvsten

    2010-01-01

    The location and three-dimensional (3D) shapes of the otosclerotic foci suggest a general centripetal distribution of otosclerotic bone remodeling around the inner ear space, whereas the normal bone remodeling is distributed centrifugally. The existence of an inverse spatial relation between normal...

  1. Computer Generated Holography as a Three-Dimensional Display Medium

    Science.gov (United States)

    1990-12-01

    series of two dimensional images are reflected on an object screen resulting in an autostereoscopic , or true three dimensional, images. The advantages of...an attractive target to optimize. Jack Ritter has suggested a fast approximation to 3D Euclidean distance calculations (10:432). His methid uses no

  2. Resistive drift wave turbulence in a three-dimensional geometry

    DEFF Research Database (Denmark)

    Korsholm, Søren Bang; Michelsen, Poul; Naulin, V.

    1999-01-01

    The Hasegawa-Wakatani model describing resistive drift waves is investigated analytically and numerically in a three-dimensional periodic geometry. After an initial growth of the energy the drift waves couple nonlinearly to convective cells, which eventually dominate the system completely...

  3. Three-Dimensional Evolution of the Galactic Fountain

    CERN Document Server

    D'Avillez, M A

    1999-01-01

    Gas that escapes from the Galactic disk, rises into the halo, cools and falls back, constitutes a "Galactic Fountain". Three-Dimensional simulations show that such a fountain model reproduces many of the features that have been observed in the Galaxy and other galaxies such as M31 and M33. Here, these results are reported.

  4. Highly monodisperse bismuth nanoparticles and their three-dimensional superlattices.

    Science.gov (United States)

    Yarema, Maksym; Kovalenko, Maksym V; Hesser, Günter; Talapin, Dmitri V; Heiss, Wolfgang

    2010-11-01

    A simple and reproducible synthesis of highly monodisperse and ligand-protected bismuth nanoparticles (Bi NPs) is reported. The size of the single-crystalline and spherically shaped NPs is controlled between 11 and 22 nm mainly by the reaction temperature. The high uniformity of the NPs allows their self-assembly into long-range-ordered two- and three-dimensional superstructures.

  5. Three-Dimensional Bone Adaptation of the Proximal Femur

    DEFF Research Database (Denmark)

    Bagge, Mette

    1998-01-01

    The bone remodeling of a three-dimensional model of the proximal femur is considered. The bone adaptation is numerically described as an evolution in time formulated such that the structural change goes in an optimal direction within each time step for the optimal boundary conditions. In the bone...

  6. THE THREE DIMENSIONAL MODELS AND THEIR IDENTIFICATION MINING SUBSIDENCE

    Institute of Scientific and Technical Information of China (English)

    WUGe; SHENGuanghan; JIXiaoming; WANGQuanke

    1995-01-01

    The theory and method for selecting the three dimensional prediction models of mining subsidence are studied in this paper. Namely, based on system identification and statistics theory, an optimum mining subsidence prediction model can be selected. The method proved by a typical case has a good prospect for determining the physical model of rock mass for mining subsidence prediction.

  7. BIFURCATION OF PERIODIC ORBITS OF A THREE-DIMENSIONAL SYSTEM

    Institute of Scientific and Technical Information of China (English)

    LIU XUANLIANG; HAN MAOAN

    2005-01-01

    Consider a three-dimensional system having an invariant surface. By using bifurcation techniques and analyzing the solutions of bifurcation equations, the authors study the spacial bifurcation phenomena of a k multiple closed orbit in the invariant surface.The sufficient conditions of the existence of many closed orbits bifurcate from the k multiple closed orbit are obtained.

  8. Three dimensional geometric modeling of processing-tomatoes

    Science.gov (United States)

    Characterizing tomato geometries with different shapes and sizes would facilitate the design of tomato processing equipments and promote computer-based engineering simulations. This research sought to develop a three-dimensional geometric model that can describe the morphological attributes of proce...

  9. Thermodynamics of a Simple Three-Dimensional DNA Hairpin Model

    CERN Document Server

    Kremer, Kellan; Boggess, Erin; Mask, Walker; Saucedo, Tony; Hansen, JJ; Appelgate, Ian; Jurgensen, Taylor; Santos, Aaron

    2016-01-01

    We characterize the equation of state for a simple three-dimensional DNA hairpin model using a Metropolis Monte Carlo algorithm. This algorithm was run at constant temperature and fixed separation between the terminal ends of the strand. From the equation of state, we compute the compressibility, thermal expansion coefficient, and specific heat along with adiabatic path.

  10. Three-dimensional simulations of viscoelastic instability in polymeric filaments

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Hassager, Ole

    1999-01-01

    The three-dimensional Langrangian integral method is used to simulate the elastic end-plate instability that occurs in the rapid extension of some polymeric filaments between parallel plates. It is demonstrated that the upper convected Maxwell model describes the essential features of the instabi...

  11. Two-Dimensional Chirality in Three-Dimensional Chemistry.

    Science.gov (United States)

    Wintner, Claude E.

    1983-01-01

    The concept of two-dimensional chirality is used to enhance students' understanding of three-dimensional stereochemistry. This chirality is used as a key to teaching/understanding such concepts as enaniotropism, diastereotopism, pseudoasymmetry, retention/inversion of configuration, and stereochemical results of addition to double bonds. (JN)

  12. A Three-Dimensional Haptic Matrix Test of Nonverbal Reasoning

    Science.gov (United States)

    Miller, Joseph C.; Skillman, Gemma D.; Benedetto, Joanne M.; Holtz, Ann M.; Nassif, Carrie L.; Weber, Anh D.

    2007-01-01

    Three-dimensional haptic matrices were pilot-tested as a nonvisual measure of cognitive ability. The results indicated that they correlated with convergent measures, with emphasis on spatial processing and that the participants who described items "visually" completed them more quickly and accurately and tended to have become visually impaired…

  13. Polycrystalline diamond detectors with three-dimensional electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Lagomarsino, S., E-mail: lagomarsino@fi.infn.it [University of Florence, Department of Physics, Via Sansone 1, 50019 Sesto Fiorentino (Italy); INFN Firenze, Via B. Rossi 1, 50019 Sesto Fiorentino (Italy); Bellini, M. [INO-CNR Firenze, Largo E. Fermi 6, 50125 Firenze (Italy); Brianzi, M. [INFN Firenze, Via B. Rossi 1, 50019 Sesto Fiorentino (Italy); Carzino, R. [Smart Materials-Nanophysics, Istituto Italiano di Tecnologia, Genova, Via Morego 30, 16163 Genova (Italy); Cindro, V. [Joseph Stefan Institute, Jamova Cesta 39, 1000 Ljubljana (Slovenia); Corsi, C. [University of Florence, Department of Physics, Via Sansone 1, 50019 Sesto Fiorentino (Italy); LENS Firenze, Via N. Carrara 1, 50019 Sesto Fiorentino (Italy); Morozzi, A.; Passeri, D. [INFN Perugia, Perugia (Italy); Università degli Studi di Perugia, Dipartimento di Ingegneria, via G. Duranti 93, 06125 Perugia (Italy); Sciortino, S. [University of Florence, Department of Physics, Via Sansone 1, 50019 Sesto Fiorentino (Italy); INFN Firenze, Via B. Rossi 1, 50019 Sesto Fiorentino (Italy); Servoli, L. [INFN Perugia, Perugia (Italy)

    2015-10-01

    The three-dimensional concept in diamond detectors has been applied, so far, to high quality single-crystal material, in order to test this technology in the best available conditions. However, its application to polycrystalline chemical vapor deposited diamond could be desirable for two reasons: first, the short inter-electrode distance of three-dimensional detectors should improve the intrinsically lower collection efficiency of polycrystalline diamond, and second, at high levels of radiation damage the performances of the poly-crystal material are not expected to be much lower than those of the single crystal one. We report on the fabrication and test of three-dimensional polycrystalline diamond detectors with several inter-electrode distances, and we demonstrate that their collection efficiency is equal or higher than that obtained with conventional planar detectors fabricated with the same material. - Highlights: • Pulsed laser fabrication of polycristalline diamond detectors with 3D electrodes. • Measurement of the charge collection efficiency (CCE) under beta irradiation. • Comparation between the CCE of 3D and conventional planar diamond sensors. • A rationale for the behavior of three-dimensional and planar sensors is given.

  14. Potential Flows From Three-Dimensional Complex Variables

    Science.gov (United States)

    Martin, E. Dale; Kelly, Patrick H.; Panton, Ronald L.

    1992-01-01

    Report presents investigation of several functions of three-dimensional complex variable, with emphasis on potential-flow fields computed from these functions. Part of continuing research on generalization of well-established two-dimensional complex analysis to three and more dimensions.

  15. Three-dimensional modes of a symmetric nonlinear plane waveguide

    Science.gov (United States)

    Akhmediev, N. N.; Nabiev, R. F.; Popov, Yu. M.

    1989-01-01

    The three-dimensional problem of a symmetric nonlinear plane waveguide, which consist of a linear medium layer surrounded by nonlinear media, is investigated. The stationary solution of this problem is a mode whose field is falling to zero at infinity in all directions perpendicular to the propagation direction. The even, odd and assymetrical solutions of the problem are obtained.

  16. Oblique water entry of a three dimensional body

    Directory of Open Access Journals (Sweden)

    Scolan Yves-Marie

    2014-12-01

    Full Text Available The problem of the oblique water entry of a three dimensional body is considered. Wagner theory is the theoretical framework. Applications are discussed for an elliptic paraboloid entering an initially flat free surface. A dedicated experimental campaign yields a data base for comparisons. In the present analysis, pressure, force and dynamics of the wetted surface expansion are assessed.

  17. Three-Dimensional Reconstruction of Macroscopic Features in Biological Materials

    Science.gov (United States)

    Krumnikl, Michal; Sojka, Eduard; Gaura, Jan; Motyka, Oldřich

    This paper covers the topic of three dimensional reconstruction of small textureless formations usually found in biological samples. Generally used reconstructing algorithms do not provide sufficient accuracy for surface analysis. In order to achieve better results, combined strategy was developed, linking stereo matching algorithms with monocular depth cues such as depth from focus and depth from illumination.

  18. Three-dimensional stiffness of the carpal arch.

    Science.gov (United States)

    Gabra, Joseph N; Li, Zong-Ming

    2016-01-01

    The carpal arch of the wrist is formed by irregularly shaped carpal bones interconnected by numerous ligaments, resulting in complex structural mechanics. The purpose of this study was to determine the three-dimensional stiffness characteristics of the carpal arch using displacement perturbations. It was hypothesized that the carpal arch would exhibit an anisotropic stiffness behavior with principal directions that are oblique to the conventional anatomical axes. Eight (n=8) cadavers were used in this study. For each specimen, the hamate was fixed to a custom stationary apparatus. An instrumented robot arm applied three-dimensional displacement perturbations to the ridge of trapezium and corresponding reaction forces were collected. The displacement-force data were used to determine a three-dimensional stiffness matrix using least squares fitting. Eigendecomposition of the stiffness matrix was used to identify the magnitudes and directions of the principal stiffness components. The carpal arch structure exhibited anisotropic stiffness behaviors with a maximum principal stiffness of 16.4±4.6N/mm that was significantly larger than the other principal components of 3.1±0.9 and 2.6±0.5N/mm (pcarpal tunnel which is accounted for by the stiff transverse ligaments that tightly bind distal carpal arch. The minimal principal stiffness is attributed to the less constraining articulation between the trapezium and scaphoid. This study provides advanced characterization of the wrist׳s three-dimensional structural stiffness for improved insight into wrist biomechanics, stability, and function.

  19. Three-Dimensional Space to Assess Cloud Interoperability

    Science.gov (United States)

    2013-03-01

    major cloud providers, OpenStack and OpeNebula, to demonstrate the usage of the three-dimensional space and its benefits . We start this chapter with a...documentation:rel4.0:external_auth. [68] X. Gao, P. Shah, A. Yoga , A. Kodgire and X. Ni. Cloud storage survey [Online]. Available: http

  20. Three-dimensional charge transport in organic semiconductor single crystals.

    Science.gov (United States)

    He, Tao; Zhang, Xiying; Jia, Jiong; Li, Yexin; Tao, Xutang

    2012-04-24

    Three-dimensional charge transport anisotropy in organic semiconductor single crystals - both plates and rods (above and below, respectively, in the figure) - is measured in well-performing organic field-effect transistors for the first time. The results provide an excellent model for molecular design and device preparation that leads to good performance.

  1. Differential equations of the shell suspension. Three-dimensional problem

    OpenAIRE

    Гнатейко, Нонна Валентинівна

    2016-01-01

    Differential equations of suspension of gyroscope are constructed as a shell of rotation. Analytical material well-being of analysis of properties of suspension as a system with part parameters is created. Three-dimensional approach gives possibility for the comprehensive study of errors of devices of inertial navigation from position impedance status.

  2. Yttrium oxide based three dimensional metamaterials for visible light cloaking

    Science.gov (United States)

    Rai, Pratyush; Kumar, Prashanth S.; Varadan, Vijay K.; Ruffin, Paul; Brantley, Christina; Edwards, Eugene

    2014-04-01

    Metamaterial with negative refractive index is the key phenomenon behind the concept of a cloaking device to hide an object from light in visible spectrum. Metamaterials made of two and three dimensional lattices of periodically placed electromagnetic resonant cells can achieve absorption and propagation of incident electromagnetic radiation as confined electromagnetic fields confined to a waveguide as surface plasmon polaritons, which can be used for shielding an object from in-tune electromagnetic radiation. The periodicity and dimensions of resonant cavity determine the frequency, which are very small as compared to the wavelength of incident light. Till now the phenomena have been demonstrated only for lights in near infrared spectrum. Recent advancements in fabrication techniques have made it possible to fabricate array of three dimensional nanostructures with cross-sections as small as 25 nm that are required for negative refractive index for wavelengths in visible light spectrum of 400-700 nm and for wider view angle. Two types of metamaterial designs, three dimensional concentric split ring and fishnet, are considered. Three dimensional structures consisted of metal-dielectric-metal stacks. The metal is silver and dielectric is yttrium oxide, other than conventional materials such as FR4 and Duroid. High κ dielectric and high refractive index as well as large crystal symmetry of Yttrium oxide has been investigated as encapsulating medium. Dependence of refractive index on wavelength and bandwidth of negative refractive index region are analyzed for application towards cloaking from light in visible spectrum.

  3. Polyimide Aerogels with Three-Dimensional Cross-Linked Structure

    Science.gov (United States)

    Meador, Mary Ann B. (Inventor)

    2016-01-01

    A method for creating a three dimensional cross-linked polyimide structure includes dissolving a diamine, a dianhydride, and a triamine in a solvent, imidizing a polyamic acid gel by heating the gel, extracting the gel in a second solvent, supercritically drying the gel, and removing the solvent to create a polyimide aerogel.

  4. Three-dimensional reconstruction of the pigeon inner ear

    NARCIS (Netherlands)

    Hofman, R.; Segenhout, J. M.; Wit, H. P.

    2009-01-01

    Three-dimensional reconstructions of the inner ear of the pigeon (Columba livia domestica), from two-dimensional images, obtained with (conventional) light microscopy or orthogonal-plane fluorescence optical sectioning (OPFOS), are presented. The results are compared with available information on th

  5. Renormalization group theory of the three dimensional dilute Bose gas

    NARCIS (Netherlands)

    Bijlsma, M.; Stoof, H.T.C.

    1996-01-01

    We study the three-dimensional atomic Bose gas using renormalization group techniques. Using our knowledge of the microscopic details of the interatomic interaction, we determine the correct initial values of our renormalization group equations and thus obtain also information on nonuniversal

  6. Algebraic Ricci Solitons of three-dimensional Lorentzian Lie groups

    CERN Document Server

    Batat, Wafaa

    2011-01-01

    We classify Algebraic Ricci Solitons of three-dimensional Lorentzian Lie groups. All algebraic Ricci solitons that we obtain are sol-solitons. In particular, we prove that, contrary to the Riemannian case, Lorentzian Ricci solitons need not to be algebraic Ricci solitons.

  7. Three-Dimensional Printing Using a Photoinitiated Polymer

    Science.gov (United States)

    Muskin, Joseph; Ragusa, Matthew; Gelsthorpe, Thomas

    2010-01-01

    Printers capable of producing three-dimensional objects are becoming more common. Most of these printers are impractical for use in the chemistry classroom because of the expense incurred in fabricating a print head that must be controlled in three dimensions. We propose a simpler solution to this problem that allows the emerging technology of…

  8. Three dimensional boundary layers on submarine conning towers and rudders

    Science.gov (United States)

    Gleyzes, C.

    1988-01-01

    Solutions for the definition of grids adapted to the calculation of three-dimensional boundary layers on submarine conning towers and on submarine rudders and fins are described. The particular geometry of such bodies (oblique shaped hull, curved fins) required special adaptations. The grids were verified on examples from a test basin.

  9. Three-Dimensional Printing Using a Photoinitiated Polymer

    Science.gov (United States)

    Muskin, Joseph; Ragusa, Matthew; Gelsthorpe, Thomas

    2010-01-01

    Printers capable of producing three-dimensional objects are becoming more common. Most of these printers are impractical for use in the chemistry classroom because of the expense incurred in fabricating a print head that must be controlled in three dimensions. We propose a simpler solution to this problem that allows the emerging technology of…

  10. Three-dimensional topology optimized electrically-small conformal antenna

    DEFF Research Database (Denmark)

    Erentok, Aycan; Sigmund, Ole

    2008-01-01

    A three-dimensional (3D) conductor-based conformal electrically small antenna is obtained using a topology optimization method. The optimization method distributes a certain amount of conductive material to a designated design domain such that the material layout defines an electrically small...

  11. Optimal eavesdropping in cryptography with three-dimensional quantum states.

    Science.gov (United States)

    Bruss, D; Macchiavello, C

    2002-03-25

    We study optimal eavesdropping in quantum cryptography with three-dimensional systems, and show that this scheme is more secure against symmetric attacks than protocols using two-dimensional states. We generalize the according eavesdropping transformation to arbitrary dimensions, and discuss the connection with optimal quantum cloning.

  12. A Novel Three-Dimensional Tool for Teaching Human Neuroanatomy

    Science.gov (United States)

    Estevez, Maureen E.; Lindgren, Kristen A.; Bergethon, Peter R.

    2010-01-01

    Three-dimensional (3D) visualization of neuroanatomy can be challenging for medical students. This knowledge is essential in order for students to correlate cross-sectional neuroanatomy and whole brain specimens within neuroscience curricula and to interpret clinical and radiological information as clinicians or researchers. This study implemented…

  13. Three-dimensional reconstruction of the otosclerotic focus

    DEFF Research Database (Denmark)

    Bloch, Sune Land; Sørensen, Mads Sølvsten

    2010-01-01

    The location and three-dimensional (3D) shapes of the otosclerotic foci suggest a general centripetal distribution of otosclerotic bone remodeling around the inner ear space, whereas the normal bone remodeling is distributed centrifugally. The existence of an inverse spatial relation between normal...

  14. Scattering and conductance quantization in three-dimensional metal nanocontacts

    DEFF Research Database (Denmark)

    Brandbyge, Mads; Jacobsen, Karsten Wedel; Nørskov, Jens Kehlet

    1997-01-01

    The transmission through three-dimensional nanocontacts is calculated in the presence of localized scattering centers and boundary scattering using a coupled-channel recursion method. Simple confining potentials are used to investigate how robust the observation of quantized conductance is with r...

  15. Three-Dimensional Extension of a Digital Library Service System

    Science.gov (United States)

    Xiao, Long

    2010-01-01

    Purpose: The paper aims to provide an overall methodology and case study for the innovation and extension of a digital library, especially the service system. Design/methodology/approach: Based on the three-dimensional structure theory of the information service industry, this paper combines a comprehensive analysis with the practical experiences…

  16. Exploring Approaches to Teaching in Three-Dimensional Virtual Worlds

    Science.gov (United States)

    Englund, Claire

    2017-01-01

    Purpose: The purpose of this paper is to explore how teachers' approaches to teaching and conceptions of teaching and learning with educational technology influence the implementation of three-dimensional virtual worlds (3DVWs) in health care education. Design/methodology/approach: Data were collected through thematic interviews with eight…

  17. Three dimensional rigorous model for optical scattering problems

    NARCIS (Netherlands)

    Wei, X.

    2006-01-01

    We present a three-dimensional model based on the finite element method for solving the time-harmonic Maxwell equation in optics. It applies to isotropic or anisotropic dielectrics and metals, and to many configurations such as an isolated scatterer in a multilayer, bi-gratings and crystals. We shal

  18. Three-Dimensional Waves in Tilt Thermal Boundary Layers

    Institute of Scientific and Technical Information of China (English)

    TAO Jian-Jun; YUAN Xiang-Jiang

    2009-01-01

    We numerically and theoretically study the stabilities of tilt thermal boundary layers immersed in stratified air. An interesting phenomenon is revealed: the stationary longitudinal-roll mode becomes unstable to some oscillating state even when the Grashof number is smaller than its corresponding critical value. By stability analysis, this phenomenon is explained in terms of a new three-dimensional wave mode. The effect of the tilt angle on the stability of the boundary flows is investigated. Since the new three-dimensional wave is found to be the most unstable mode when the title angle is between 30° and 64°, it is expected to play an important role in the transition to turbulence.

  19. Three-dimensional P velocity structure in Beijing area

    Institute of Scientific and Technical Information of China (English)

    于湘伟; 陈运泰; 王培德

    2003-01-01

    A detail three-dimensional P wave velocity structure of Beijing, Tianjin and Tangshan area (BTT area) was determined by inverting local earthquake data. In total 16 048 P wave first arrival times from 16048 shallow and mid-depth crustal earthquakes, which occurred in and around the BTT area from 1992 to 1999 were used. The first arrival times are recorded by Northern China United Telemetry Seismic Network and Yanqing-Huailai Digital Seismic Network. Hypocentral parameters of 1 132 earthquakes with magnitude ML=1.7~6.2 and the three-dimensional P wave velocity structure were obtained simultaneously. The inversion result reveals the complicated lateral heterogeneity of P wave velocity structure around BTT area. The tomographic images obtained are also found to explain other seismological observations well.

  20. Three-dimensional radiation transfer modeling in a dicotyledon leaf

    Science.gov (United States)

    Govaerts, Yves M.; Jacquemoud, Stéphane; Verstraete, Michel M.; Ustin, Susan L.

    1996-11-01

    The propagation of light in a typical dicotyledon leaf is investigated with a new Monte Carlo ray-tracing model. The three-dimensional internal cellular structure of the various leaf tissues, including the epidermis, the palisade parenchyma, and the spongy mesophyll, is explicitly described. Cells of different tissues are assigned appropriate morphologies and contain realistic amounts of water and chlorophyll. Each cell constituent is characterized by an index of refraction and an absorption coefficient. The objective of this study is to investigate how the internal three-dimensional structure of the tissues and the optical properties of cell constituents control the reflectance and transmittance of the leaf. Model results compare favorably with laboratory observations. The influence of the roughness of the epidermis on the reflection and absorption of light is investigated, and simulation results confirm that convex cells in the epidermis focus light on the palisade parenchyma and increase the absorption of radiation.

  1. Three Dimensional Energy Transmitting Boundary in the Time Domain

    Directory of Open Access Journals (Sweden)

    Naohiro eNakamura

    2015-11-01

    Full Text Available Although the energy transmitting boundary is accurate and efficient for the FEM earthquake response analysis, it could be applied in the frequency domain only. In the previous papers, the author proposed an earthquake response analysis method using the time domain energy transmitting boundary for two dimensional problems. In this paper, this technique is expanded for three dimensional problems. The inner field is supposed to be a hexahedron shape and the approximate time domain boundary is explained, first. Next, two dimensional anti-plane time domain boundary is studied for a part of the approximate three dimensional boundary method. Then, accuracy and efficiency of the proposed method are confirmed by example problems.

  2. Three-Dimensional Structure of Solar Wind Turbulence

    CERN Document Server

    Chen, C H K; Schekochihin, A A; Horbury, T S; Wicks, R T; Bale, S D

    2011-01-01

    We have measured, for the first time, the three-dimensional structure of inertial range plasma turbulence in the fast solar wind with respect to a local, physically motivated coordinate system. We found that the incompressible Alfvenic fluctuations are three-dimensionally anisotropic, with the sense of this anisotropy changing from large to small scales. At the largest scales, the magnetic field correlations are longest in the local fluctuation direction, consistent with Alfven waves. At the smallest scales, they are longest along the local mean field direction and shortest in the direction perpendicular to the local mean field and the local field fluctuation. The compressive fluctuations are highly elongated along the local mean magnetic field direction, although axially symmetric perpendicular to it. Their large anisotropy may explain why they are not heavily damped.

  3. Three-dimensional mapping of single-atom magnetic anisotropy.

    Science.gov (United States)

    Yan, Shichao; Choi, Deung-Jang; Burgess, Jacob A J; Rolf-Pissarczyk, Steffen; Loth, Sebastian

    2015-03-11

    Magnetic anisotropy plays a key role in the magnetic stability and spin-related quantum phenomena of surface adatoms. It manifests as angular variations of the atom's magnetic properties. We measure the spin excitations of individual Fe atoms on a copper nitride surface with inelastic electron tunneling spectroscopy. Using a three-axis vector magnet we rotate the magnetic field and map out the resulting variations of the spin excitations. We quantitatively determine the three-dimensional distribution of the magnetic anisotropy of single Fe atoms by fitting the spin excitation spectra with a spin Hamiltonian. This experiment demonstrates the feasibility of fully mapping the vector magnetic properties of individual spins and characterizing complex three-dimensional magnetic systems.

  4. Atomic force microscope study of three-dimensional nanostructure sidewalls

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Muhammad Mustafa [SEMATECH, 2706 Montopolis Drive, Austin, TX 78741 (United States); Gondran, Carolyn F H [Advanced Technology Development Facility, 2706 Montopolis Drive, Austin, TX 78741 (United States); Michelson, Diane K [International SEMATECH Manufacturing Initiative, 2706 Montopolis Drive, Austin, TX 78741 (United States)

    2007-08-22

    Next generation planar and non-planar complementary metal oxide semiconductor (CMOS) structures are three-dimensional nanostructures with multi-layer stacks that can contain films thinner than ten atomic layers. The high resolution of transmission electron microscopy (TEM) is typically chosen for studying properties of these stacks such as film thickness, interface and interfacial roughness. However, TEM sample preparation is time-consuming and destructive, and TEM analysis is expensive and can provide problematic results for surface and interface roughness. Therefore, in this paper, we present the use of direct measurements of sidewall surface structures by conventional atomic force microscopy (AFM) as an alternative or complementary method for studying multi-layer film stacks and as the preferred method for studying FinFET sidewall surface roughness. In addition to these semiconductor device applications, this AFM sidewall measurement technique could be used for other three-dimensional nanostructures.

  5. Three-dimensional hybrid networks based on aspartic acid

    Indian Academy of Sciences (India)

    Anupama Ghosh; R A Sanguramath

    2008-01-01

    Three-dimensional achiral coordination polymers of the general formula M2(D, L-NHCH (COO)CH2COO)2.C4H4N2 where M = Ni and Co and pyrazine acts as the linker molecule have been prepared under hydrothermal conditions starting with [M(L-NHCH(COO)CH2COO).3H2O] possessing a helical chain structure. A three-dimensional hybrid compound of the formula Pb2.5[N{CH(COO)CH2COO}22H2O] has also been prepared hydrothermally starting with aspartic acid and Pb(NO3)2. In this lead compound, where a secondary amine formed by the dimerisation of aspartic acid acts as the ligand, there is two-dimensional inorganic connectivity and one-dimensional organic connectivity.

  6. Artificial three-dimensional niches deconstruct pancreas development in vitro.

    Science.gov (United States)

    Greggio, Chiara; De Franceschi, Filippo; Figueiredo-Larsen, Manuel; Gobaa, Samy; Ranga, Adrian; Semb, Henrik; Lutolf, Matthias; Grapin-Botton, Anne

    2013-11-01

    In the context of a cellular therapy for diabetes, methods for pancreatic progenitor expansion and subsequent differentiation into insulin-producing beta cells would be extremely valuable. Here we establish three-dimensional culture conditions in Matrigel that enable the efficient expansion of dissociated mouse embryonic pancreatic progenitors. By manipulating the medium composition we generate either hollow spheres, which are mainly composed of pancreatic progenitors, or complex organoids that spontaneously undergo pancreatic morphogenesis and differentiation. The in vitro maintenance and expansion of pancreatic progenitors require active Notch and FGF signaling, thus recapitulating in vivo niche signaling interactions. Our experiments reveal new aspects of pancreas development, such as a community effect by which small groups of cells better maintain progenitor properties and expand more efficiently than isolated cells, as well as the requirement for three-dimensionality. Finally, growth conditions in chemically defined biomaterials pave the way for testing the biophysical and biochemical properties of the niche that sustains pancreatic progenitors.

  7. Time multiplexed pinhole array based lensless three-dimensional imager

    Science.gov (United States)

    Schwarz, Ariel; Wang, Jingang; Shemer, Amir; Zalevsky, Zeev; Javidi, Bahram

    2016-06-01

    We present an overview of multi variable coded aperture (MVCA) for lensless three-dimensional integral imaging (3D II) systems. The new configuration is based on a time multiplexing method using a variable pinholes array design. The system provides higher resolution 3D images with improved light intensity and signal to noise ratio as compared to single pinhole system. The MVCA 3D II system configuration can be designed to achieve high light intensity for practical use as micro lenslets arrays. This new configuration preserves the advantages of pinhole optics while solving the resolution limitation problem and the long exposure time of such systems. The three dimensional images are obtained with improved resolution, signal to noise ratio and sensitivity efficiency. This integral imaging lensless system is characterized by large depth of focus, simplicity and low cost. In this paper we present numerical simulations as well as experimental results that validate the proposed lensless imaging configuration.

  8. Electroencephalographic (EEG) control of three-dimensional movement

    Science.gov (United States)

    McFarland, Dennis J.; Sarnacki, William A.; Wolpaw, Jonathan R.

    2010-06-01

    Brain-computer interfaces (BCIs) can use brain signals from the scalp (EEG), the cortical surface (ECoG), or within the cortex to restore movement control to people who are paralyzed. Like muscle-based skills, BCIs' use requires activity-dependent adaptations in the brain that maintain stable relationships between the person's intent and the signals that convey it. This study shows that humans can learn over a series of training sessions to use EEG for three-dimensional control. The responsible EEG features are focused topographically on the scalp and spectrally in specific frequency bands. People acquire simultaneous control of three independent signals (one for each dimension) and reach targets in a virtual three-dimensional space. Such BCI control in humans has not been reported previously. The results suggest that with further development noninvasive EEG-based BCIs might control the complex movements of robotic arms or neuroprostheses.

  9. Three-Dimensional All-Dielectric Photonic Topological Insulator

    CERN Document Server

    Slobozhanyuk, Alexey; Ni, Xiang; Smirnova, Daria; Kivshar, Yuri S; Khanikaev, Alexander B

    2016-01-01

    The discovery of two-dimensional topological photonic systems has transformed our views on electromagnetic propagation and scattering of classical waves, and a quest for similar states in three dimensions, known to exist in condensed matter systems, has been put forward. Here we demonstrate that symmetry protected three-dimensional topological states can be engineered in an all-dielectric platform with the electromagnetic duality between electric and magnetic fields ensured by the structure design. Magneto-electric coupling playing the role of a synthetic gauge field leads to a topological transition to an insulating regime with a complete three-dimensional photonic bandgap. An emergence of surface states with conical Dirac dispersion and spin-locking is unimpeded. Robust propagation of surface states along two-dimensional domain walls defined by the reversal of magneto-electric coupling is confirmed numerically by first principle studies. It is shown that the proposed system represents a table-top platform f...

  10. Moyamoya disease: diagnosis with three-dimensional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Radiology, Kyorin Univ. School of Medicine, Tokyo (Japan)); Makita, K. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Radiology, Social Health Insurance Medical Center, Tokyo (Japan)); Furui, S. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Diagnostic Radiology, Toranomon Kyosai Hospital, Tokyo (Japan))

    1994-08-01

    Our purpose was to assess the value of three-dimensional (3D) CT angiography in the diagnosis of moyamoya disease. We studied seven patients with moyamoya disease proved by conventional angiography. Three-dimensional (3D) CT angiography was performed using rapid sequence or helical (spiral) scanning in conjunction with a bolus injection of intravenous contrast medium. All seven patients could be diagnosed as having moyamoya disease on the basis of the following 3D CT angiographic findings: poor visualisation of the main trunks and/or major branches of anterior and middle cerebral arteries (7 patients); dilated leptomeningeal anastomotic channels from the posterior cerebral arteries (4); and demonstration of ''moyamoya vessels'' in the basal ganglia (2). Although conventional angiography remains the principal imaging technique for demonstrating anatomical changes in detail, less invasive 3D CT angiography provides a solid means of diagnosing moyamoya disease when it is suspected on CT, MRI, or clinical grounds. (orig.)

  11. Three-Dimensional Modeling of Guide-Field Magnetic Reconnection

    Science.gov (United States)

    Hesse, Michael

    2005-01-01

    The dissipation mechanism of guide field magnetic reconnection remains a subject of intense scientific interest. On one hand, one set of recent studies have shown that particle inertia-based processes, which include thermal and bulk inertial effects, provide the reconnection electric field in the diffusion region. On the other hand, a second set of studies emphasizes the role of wave-particle interactions in providing anomalous resistivity in the diffusion region. In this presentation, we analyze three-dimensional PIC simulations of guide-field magnetic reconnection. Specific emphasis will be on the question whether thermal-inertia processes, mediated by the electron pressure tensor, remain a viable dissipation mechanism in fully three-dimensional systems.

  12. Slightly Two or Three Dimensional Self-Similar Solutions

    CERN Document Server

    Sari, Re'em; Yalinewich, Almog; MacFadyen, Andrew

    2011-01-01

    Self similarity allows for analytic or semi-analytic solutions to many hydrodynamics problems. Most of these solutions are one dimensional. Using linear perturbation theory, expanded around such a one-dimensional solution, we find self-similar hydrodynamic solutions that are two- or three-dimensional. Since the deviation from a one-dimensional solution is small, we call these slightly two-dimensional and slightly three-dimensional self-similar solutions, respectively. As an example, we treat strong spherical explosions of the second type. A strong explosion propagates into an ideal gas with negligible temperature and density profile of the form rho(r,theta,phi)=r^{-omega}[1+sigma*F(theta,phi)], where omega>3 and sigma << 1. Analytical solutions are obtained by expanding the arbitrary function F(theta,phi) in spherical harmonics. We compare our results with two dimensional numerical simulations, and find good agreement.

  13. Three-Dimensional Dynamical Instabilities in Galactic Ionization Fronts

    CERN Document Server

    Whalen, D J; Whalen, Daniel J.; Norman, Michael L.

    2007-01-01

    Ionization front instabilities have long been of interest for their suspected role in a variety of phenomena in the galaxy, from the formation of bright rims and 'elephant trunks' in nebulae to triggered star formation in molecular clouds. Numerical treatments of these instabilities have historically been limited in both dimensionality and input physics, leaving important questions about their true evolution unanswered. We present the first three-dimensional radiation hydrodynamical calculations of both R-type and D-type ionization front instabilities in galactic environments (i.e., solar metallicity gas). Consistent with linear stability analyses of planar D-type fronts, our models exhibit many short-wavelength perturbations growing at early times that later evolve into fewer large-wavelength structures. The simulations demonstrate that both self-consistent radiative transfer and three-dimensional flow introduce significant morphological differences to unstable modes when compared to earlier two-dimensional ...

  14. Stability analysis of cracks propagating in three dimensional solids

    Energy Technology Data Exchange (ETDEWEB)

    Larralde, H.; Al-Falou, A.A.; Ball, R.C. [Cavendish Lab., Cambridge (United Kingdom)

    1996-12-01

    The authors present a theory for the morphology of the fracture surface left behind by slowly propagating cracks in linear, isotropic and homogeneous three dimensional solids. The results are based on first order perturbation theory of the equations of elasticity for cracks whose shape is slightly perturbed from planar. For cracks propagating under pure type 1 loading they find that all perturbation modes are linearly stable, from which they can predict the roughness of the fracture surface induced by fluctuations in the material. The authors compare their results with the classical results for cracks propagating in two dimensional systems, and discuss the effects in the three dimensional analysis which result from taking into account contributions from non-singular terms of the stress field, as well as the effects arising from finite speeds of crack propagation.

  15. Magnetic field intensification by three-dimensional explosion process

    CERN Document Server

    Hotta, H; Yokoyama, T

    2012-01-01

    We investigate an intensification mechanism for the magnetic field near the base of the solar convection zone that does not rely on differential rotation. Such mechanism in addition to differential rotation has been suggested by studies of flux emergence, which typically require field strength in excess of those provided by differential rotation alone. We study here a process in which potential energy of the superadiabatically stratified convection zone is converted into magnetic energy. This mechanism, know as explosion of magnetic flux tubes, has been previously studied in the thin flux tube approximation as well as two-dimensional MHD simulations, we expand the investigation to three-dimensional MHD simulations. Our main result is that enough intensification can be achieved in a three-dimensional magnetic flux sheet as long as the spatial scale of the imposed perturbation normal to the magnetic field is sufficiently large. When this spatial scale is small, the flux sheet tends to rise toward the surface, r...

  16. Canonical and symplectic analysis for three dimensional gravity without dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Escalante, Alberto, E-mail: aescalan@ifuap.buap.mx [Instituto de Física, Benemérita Universidad Autónoma de Puebla, Apartado Postal J-48 72570, Puebla, Pue. (Mexico); Osmart Ochoa-Gutiérrez, H. [Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Apartado postal 1152, 72001 Puebla, Pue. (Mexico)

    2017-03-15

    In this paper a detailed Hamiltonian analysis of three-dimensional gravity without dynamics proposed by V. Hussain is performed. We report the complete structure of the constraints and the Dirac brackets are explicitly computed. In addition, the Faddeev–Jackiw symplectic approach is developed; we report the complete set of Faddeev–Jackiw constraints and the generalized brackets, then we show that the Dirac and the generalized Faddeev–Jackiw brackets coincide to each other. Finally, the similarities and advantages between Faddeev–Jackiw and Dirac’s formalism are briefly discussed. - Highlights: • We report the symplectic analysis for three dimensional gravity without dynamics. • We report the Faddeev–Jackiw constraints. • A pure Dirac’s analysis is performed. • The complete structure of Dirac’s constraints is reported. • We show that symplectic and Dirac’s brackets coincide to each other.

  17. Three-dimensional theory for light-matter interaction

    DEFF Research Database (Denmark)

    Sørensen, Martin Westring; Sørensen, Anders Søndberg

    2008-01-01

    We present a full quantum mechanical three dimensional theory describing an electromagnetic field interacting with an ensemble of identical atoms. The theory is constructed such that it describes recent experiments on light-matter quantum interfaces, where the quantum fluctuations of light...... to a dressed state picture, where the light modes are solutions to the diffraction problem, and develop a perturbative expansion in the fluctuations. The fluctuations are due to quantum fluctuations as well as the random positions of the atoms. In this perturbative expansion we show how the quantum...... fluctuations are mapped between atoms and light while the random positioning of the atoms give rise to decay due to spontaneous emission. Furthermore we identify limits, where the full three dimensional theory reduce to the one dimensional theory typically used to describe the interaction....

  18. Three Dimensional Iterative Reconstruction Techniques in Positron Tomography.

    Science.gov (United States)

    Sloka, Scott

    The acquisition of positron tomographic data in three dimensions is an improvement over the two dimensional acquisition of data because the greater the number of measurements taken of a stochastic process, the more accurately determined the desired parameter may be. This research pursues the goal of three dimensional image reconstruction in Positron Tomography using an iterative approach. This thesis has followed a systematic approach to the exploration of a system for three dimensional iterative reconstruction. System design parameters were discussed such as the advantages and disadvantages of iterative vs analytic methods, the implementation of two, three dimensional iterative algorithms, the selection of a ray passing method, and the choice of an analytic method for comparison to the iterative methods. Several qualitative and quantitative tests were used/developed and performed to analyse and compare the results. Three dimensional reconstruction in Positron Tomography using two iterative techniques (ART and ML-EM) was demonstrated. The ML-EM algorithm was adapted to satisfy the objective of equalizing the estimates with the measurements via division of the sampling density. A new multi-objective function methodology was developed for two dimensions and its extension to three dimensions discussed. A smoothly-varying Gaussian phantom was created for comparing artifacts from different ray passing methods. The analysis of voxel trends over many iterations was used. The use of the output from a two dimensional filtered backprojection algorithm as the seed for three dimensional algorithms to accelerate the reconstruction the was explored. The importance of the selection of a good ray ordering in ART and its effects on the total squared error were explored. For the phantoms studied in this thesis, the ML -EM algorithm tended to perform better under most conditions. This algorithm is slower than ART to achieve both a low total squared error and good contrast, but the

  19. Influence of stable stratification on three-dimensional isotropic turbulence

    Science.gov (United States)

    Metais, O.

    The influence of a stable stratification on three-dimensional homogeneous turbulence is investigated by performing large eddy simulations with the subgrid scales procedure developed by Chollet and Lesieur for isotropic turbulence. Computational initial conditions close to those of the experiments performed by Itsweire, Helland and Van Atta allow the comparison of the experimental and numerical evolutions of density-stratified turbulent flows. Theoretical works by Riley, Metcalfe and Weisman and by Lilly suggest that low Froude number stably-stratified turbulence may be a nearly noninteracting superposition of wave and quasi-horizontal turbulent vortex motions. For our computations the stably-stratified turbulence seems to be a decaying three-dimensional turbulence pulsed by internal gravity waves. However some tendencies towards two-dimensional turbulence are observed.

  20. Three-dimensional metamaterials fabricated using Proton Beam Writing

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A.A., E-mail: a.bettiol@nus.edu.sg [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, 2 Science Dr. 3, Singapore 117542 (Singapore); Turaga, S.P.; Yan, Y.; Vanga, S.K. [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, 2 Science Dr. 3, Singapore 117542 (Singapore); Chiam, S.Y. [NUS High School for Maths and Science, 20 Clementi Avenue 1, Singapore 129957 (Singapore)

    2013-07-01

    Proton Beam Writing (PBW) is a direct write lithographic technique that has recently been applied to the fabrication of three dimensional metamaterials. In this work, we show that the unique capabilities of PBW, namely the ability to fabricate arrays of high resolution, high aspect ratio microstructures in polymer or replicated into metal, is well suited to metamaterials research. We have also developed a novel method for selectively electroless plating silver directly onto polymer structures that were fabricated using PBW. This method opens up new avenues for utilizing PBW for making metamaterials and other sub-wavelength metallic structures. Several potential applications of three dimensional metamaterials fabricated using PBW are discussed, including sensing and negative refractive index materials.

  1. Single florescent nanodiamond in a three dimensional ABEL trap

    Science.gov (United States)

    Kayci, Metin; Radenovic, Aleksandra

    2015-11-01

    Three dimensional single particle trapping and manipulation is an outstanding challenge in various fields ranging from basic physics to life sciences. By monitoring the response of a trapped particle to a designed environment one can extract its characteristics. In addition, quantum dynamics of a spatially scanned well-known particle can provide environmental information. Precise tracking and positioning of such a particle in aqueous environment is crucial task for achieving nano-scale resolution. Here we experimentally demonstrate three dimensional ABEL trap operating at high frequency by employing a hybrid approach in particle tracking. The particle location in the transverse plane is detected via a scanning laser beam while the axial position is determined by defocused imaging. The scanning of the trapped particle is accomplished through a nano positioning stage integrated to the trap platform.

  2. Three dimensional calculation of flux of low energy atmospheric neutrinos

    Science.gov (United States)

    Lee, H.; Bludman, S. A.

    1985-01-01

    Results of three-dimensional Monte Carlo calculation of low energy flux of atmospheric neutrinos are presented and compared with earlier one-dimensional calculations 1,2 valid at higher neutrino energies. These low energy neutrinos are the atmospheric background in searching for neutrinos from astrophysical sources. Primary cosmic rays produce the neutrino flux peaking at near E sub=40 MeV and neutrino intensity peaking near E sub v=100 MeV. Because such neutrinos typically deviate by 20 approximately 30 from the primary cosmic ray direction, three-dimensional effects are important for the search of atmospheric neutrinos. Nevertheless, the background of these atmospheric neutrinos is negligible for the detection of solar and supernova neutrinos.

  3. Three Dimensional Numerical Relativity with a Hyperbolic Formulation

    CERN Document Server

    Bona, C; Seidel, E; Walker, P; Bona, Carles; Masso, Joan; Seidel, Edward; Walker, Paul

    1998-01-01

    We discuss a successful three-dimensional cartesian implementation of the Bona-Massó hyperbolic formulation of the 3+1 Einstein evolution equations in numerical relativity. The numerical code, which we call ``Cactus,'' provides a general framework for 3D numerical relativity, and can include various formulations of the evolution equations, initial data sets, and analysis modules. We show important code tests, including dynamically sliced flat space, wave spacetimes, and black hole spacetimes. We discuss the numerical convergence of each spacetime, and also compare results with previously tested codes based on other formalisms, including the traditional ADM formalism. This is the first time that a hyperbolic reformulation of Einstein's equations has been shown appropriate for three-dimensional numerical relativity in a wide variety of spacetimes.

  4. Three-dimensional natural convection in a narrow spherical shell

    Science.gov (United States)

    Liu, Ming; Egbers, Christoph

    The convective motions in a shallow fluid layer between two concentric spheres in the presence of a constant axial force field have been studied numerically. The aspect ratio of the fluid layer to inner radius is beta =0.08, the Prandtl number Pra =37.5. A three-dimensional time-dependent numerical code is used to solve the governing equations in primitive variables. Convection in the sphe rical shell has then a highly three-dimensional nature. Characteristic flow patterns with a large number of banana-type cells, oriented in north-south direction and aligned in the azimuthal direction, are formed on the northern hemisphere, which grow gradually into the equatorial region accompanied by the generation of new cells as the Rayleigh number is increased. Various characteristics of these flows as well as their transient evolution are investigated for Rayleigh numbers up to 20 000.

  5. Three-Dimensional Reconstruction of Erythrocyte in the Capillary

    CERN Document Server

    Fan, Yifang; Li, Zhiyu; Lin, Wentao; Wei, Yuan; Zhong, Xing; Newman, Tony; Lv, Changsheng; Fan, Yuzhou

    2013-01-01

    The dynamic analysis of erythrocyte deformability is used as an important means for early diagnosis of blood diseases and blood rheology. Yet no effective method is available in terms of three-dimensional reconstruction of erythrocytes in a capillary. In this study, ultrathin serial sections of skeletal muscle tissue are obtained from the ultramicrotome, the tomographic images of an erythrocyte in a capillary are captured by the transmission electron microscope, and then a method to position and restore is devised to demonstrate the physiological relationship between two adjacent tomographic images of an erythrocyte. Both the modeling and the physical verification reveal that this method is effective, which means that it can be used to make three-dimensional reconstruction of an erythrocyte in a capillary. An example of reconstructed deformation of erythrocyte based on the serial ultrathin sections is shown at the end of this paper.

  6. Three-dimensional potential energy surface of Ar–CO

    Energy Technology Data Exchange (ETDEWEB)

    Sumiyoshi, Yoshihiro, E-mail: y-sumiyoshi@gunma-u.ac.jp [Division of Pure and Applied Science, Graduate School of Science and Technology, Gunma University, 4-2 Aramaki, Maebashi, Gunma 371-8510 (Japan); Endo, Yasuki [Department of Basic Science, Graduate School of Arts and Sciences, The University of Tokyo, Komaba, Meguro-ku, Tokyo 153-8902 (Japan)

    2015-01-14

    A three-dimensional intermolecular potential energy surface of the Ar–CO complex has been determined by fitting most of the previously reported spectroscopic data, where observed transition frequencies by microwave, millimeter-wave, submillimeter-wave, and infrared spectroscopy were reproduced simultaneously within their experimental accuracies. A free rotor model Hamiltonian considering all the freedom of motions for an atom-diatom system was applied to calculate vibration-rotation energies. A three-dimensional potential energy surface obtained by ab initio calculations at the CCSD(T)-F12b/aug-cc-pV5Z level of theory was parameterized by a model function consisting of 46 parameters. They were used as initial values for the least-squares analysis of the experimental data. A total of 20 parameters were optimized to reproduce all the spectroscopic data.

  7. Relaxation techniques for three-dimensional transonic flow about wings.

    Science.gov (United States)

    Bailey, F. R.; Steger, J. L.

    1972-01-01

    A relaxation procedure has been developed to treat the three-dimensional, transonic small perturbation equations about finite lifting wings. A combination of two schemes is employed. For flow forward of the wing trailing edge the equations are written in terms of a velocity potential in order to minimize computer algebra and storage. For the remaining flow field the equations are written in terms of the velocity components in order to simplify the enforcement of the Kutta condition. Difference equations and relaxation procedures are described for both schemes. The computational method automatically captures the imbedded shock wave in the three-dimensional flow field. Computed results are given and compared to experiment and other inviscid methods.

  8. All-optical three-dimensional electron pulse compression

    CERN Document Server

    Wong, Liang Jie; Rohwer, Timm; Gedik, Nuh; Johnson, Steven G

    2014-01-01

    We propose an all-optical, three-dimensional electron pulse compression scheme in which Hermite-Gaussian optical modes are used to fashion a three-dimensional optical trap in the electron pulse's rest frame. We show that the correct choices of optical incidence angles are necessary for optimal compression. We obtain analytical expressions for the net impulse imparted by Hermite-Gaussian free-space modes of arbitrary order. Although we focus on electrons, our theory applies to any charged particle and any particle with non-zero polarizability in the Rayleigh regime. We verify our theory numerically using exact solutions to Maxwell's equations for first-order Hermite-Gaussian beams, demonstrating single-electron pulse compression factors of $>10^{2}$ in both longitudinal and transverse dimensions with experimentally realizable optical pulses. The proposed scheme is useful in ultrafast electron imaging for both single- and multi-electron pulse compression, and as a means of circumventing temporal distortions in ...

  9. Absence of bilinear condensate in three-dimensional QED

    CERN Document Server

    Karthik, Nikhil

    2016-01-01

    There are plausibility arguments that QED in three dimensions has a critical number of flavors of massless two-component fermions, below which scale invariance is broken by the presence of bilinear condensate. We present numerical evidences from our lattice simulations using dynamical overlap as well as Wilson-Dirac fermions for the absence of bilinear condensate for any even number of flavors of two-component fermions. Instead, we find evidences for the scale-invariant nature of three-dimensional QED.

  10. Three-dimensional magnetic reconnection through a moving magnetic null

    OpenAIRE

    Lukin, V. S.; Linton, M. G.

    2011-01-01

    A computational study of three-dimensional magnetic reconnection between two flux ropes through a moving reconnection site is presented. The configuration is considered in the context of two interacting spheromaks constrained by a perfectly conducting cylindrical boundary and oriented to form a single magnetic field null at its center. The initial magnetic field configuration is embedded into a uniform thermal plasma and is unstable to tilting. As the sphe...

  11. Three-dimensional magnetic reconnection through a moving magnetic null

    OpenAIRE

    Lukin, V. S.; Linton, M. G.

    2011-01-01

    A computational study of three-dimensional magnetic reconnection between two flux ropes through a moving reconnection site is presented. The configuration is considered in the context of two interacting spheromaks constrained by a perfectly conducting cylindrical boundary and oriented to form a single magnetic field null at its center. The initial magnetic field configuration is embedded into a uniform thermal plasma and is unstable to tilting. As the spheromaks tilt, their magnetic fi...

  12. Universally applicable three-dimensional hydrodynamic microfluidic flow focusing

    OpenAIRE

    Chiu, Yu-Jui; Cho, Sung Hwan; Mei, Zhe; Lien, Victor; Wu, Tsung-Feng; Lo, Yu-Hwa

    2013-01-01

    We have demonstrated a microfluidic device that can not only achieve three-dimensional flow focusing but also confine particles to the center stream along the channel. The device has a sample channel of smaller height and two sheath flow channels of greater height, merged into the downstream main channel where 3D focusing effects occur. We have demonstrated that both beads and cells in our device display significantly lower CVs in velocity and position distributions as well as reduced probabi...

  13. APPLICATIONS OF FRACTIONAL EXTERIOR DIFFERENTIAL IN THREE-DIMENSIONAL SPACE

    Institute of Scientific and Technical Information of China (English)

    陈勇; 闫振亚; 张鸿庆

    2003-01-01

    A brief survey of fractional calculus and fractional differential forms was firstly given. The fractional exterior transition to curvilinear coordinate at the origin were discussed and the two coordinate transformations for the fractional differentials for three-dimensional Cartesian coordinates to spherical and cylindrical coordinates are obtained, respectively. In particular, for v = m = 1 , the usual exterior transformations, between the spherical coordinate and Cartesian coordinate, as well as the cylindrical coordinate and Cartesian coordinate, are found respectively, from fractional exterior transformation.

  14. MRFD Method for Scattering From Three Dimensional Dielectric Bodies

    Directory of Open Access Journals (Sweden)

    A. F. Yagli

    2011-09-01

    Full Text Available A three-dimensional multiresolution frequency domain (MRFD method is established to compute bistatic radar cross sections of arbitrarily shaped dielectric objects. The proposed formulation is successfully verified by computing the bistatic radar cross sections of a dielectric sphere and a dielectric cube. Comparing the results to those obtained from the finite difference frequency domain (FDFD method simulations and analytic calculations, we demonstrated the computational time and memory advantages of MRFD method.

  15. Three-dimensional conceptual model for service-oriented simulation

    Institute of Scientific and Technical Information of China (English)

    Wen-guang WANG; Wei-ping WANG; Justyna ZANDER; Yi-fan ZHU

    2009-01-01

    In this letter, we propose a novel three-dimensional conceptual model for an emerging service-oriented simulation paradigm. The model can be used as a guideline or an analytic means to find the potential and possible future directions of the current simulation frameworks, In particular, the model inspects the crossover between the disciplines of modeling and simulation,service-orientation, and software/systems engineering. Finally, two specific simulation frameworks are studied as examples.

  16. Three-dimensional vortex structures under breaking waves

    OpenAIRE

    WATANABE Yasunori; Saeki, Hiroshi; Hosking, Roger J.

    2005-01-01

    The large-scale vortex structures under spilling and plunging breakers are investigated, using a fully three-dimensional large-eddy simulation (LES). When an overturning jet projecting from the crest in a breaking wave rebounds from the water surface ahead, the vorticity becomes unstable in a saddle region of strain between the rebounding jet and a primary spanwise vortex, resulting in spanwise undulations of the vorticity. The undulations are amplified on a braid in this saddle region, leadi...

  17. Probability current tornado loops in three-dimensional scattering

    CERN Document Server

    Exner, P; Exner, Pavel; Seba, Petr

    1998-01-01

    We consider scattering of a three-dimensional particle on a finite family of delta potentials. For some parameter values the scattering wavenctions exhibit nodal lines in the form of closed loops, which may touch but do not entangle. The corresponding probability current forms vortical singularities around these lines; if the scattered particle is charged, this gives rise to magnetic flux loops. The conclusions extend to scattering on hard obstacles or smooth potentials.

  18. Three-dimensional, computer simulated navigation in endoscopic neurosurgery

    Directory of Open Access Journals (Sweden)

    Roberta K. Sefcik, BHA

    2017-06-01

    Conclusion: Three-dimensional, frameless neuronavigation systems are useful in endoscopic neurosurgery to assist in the pre-operative planning of potential trajectories and to help localize the pathology of interest. Neuronavigation appears to be accurate to <1–2 mm without issues related to brain shift. Further work is necessary in the investigation of the effect of neuronavigation on operative time, cost, and patient-centered outcomes.

  19. Environmental, Transient, Three-Dimensional, Hydrothermal, Mass Transport Code - FLESCOT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yasuo [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bao, Jie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glass, Kevin A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eyler, L. L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Okumura, Masahiko [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-28

    The purpose of the project was to modify and apply the transient, three-dimensional FLESCOT code to be able to effectively simulate cesium behavior in Fukushima lakes/dam reservoirs, river mouths, and coastal areas. The ultimate objective of the FLESCOT simulation is to predict future changes of cesium accumulation in Fukushima area reservoirs and costal water. These evaluation results will assist ongoing and future environmental remediation activities and policies in a systematic and comprehensive manner.

  20. Complete wetting in the three-dimensional transverse Ising model

    OpenAIRE

    Harris, A B; Micheletti, C.; Yeomans, J. M.

    1996-01-01

    We consider a three-dimensional Ising model in a transverse magnetic field, $h$ and a bulk field $H$. An interface is introduced by an appropriate choice of boundary conditions. At the point $(H=0,h=0)$ spin configurations corresponding to different positions of the interface are degenerate. By studying the phase diagram near this multiphase point using quantum-mechanical perturbation theory we show that that quantum fluctuations, controlled by $h$, split the multiphase degeneracy giving rise...

  1. A new three-dimensional general-relativistic hydrodynamics code

    Science.gov (United States)

    Baiotti, L.; Hawke, I.; Montero, P. J.; Rezzolla, L.

    We present a new three-dimensional general relativistic hydrodynamics code, the Whisky code. This code incorporates the expertise developed over the past years in the numerical solution of Einstein equations and of the hydrodynamics equations in a curved spacetime, and is the result of a collaboration of several European Institutes. We here discuss the ability of the code to carry out long-term accurate evolutions of the linear and nonlinear dynamics of isolated relativistic stars.

  2. A new three-dimensional general-relativistic hydrodynamics code

    CERN Document Server

    Baiotti, Luca; Montero, Pedro J; Rezzolla, Luciano

    2010-01-01

    We present a new three-dimensional general relativistic hydrodynamics code, the Whisky code. This code incorporates the expertise developed over the past years in the numerical solution of Einstein equations and of the hydrodynamics equations in a curved spacetime, and is the result of a collaboration of several European Institutes. We here discuss the ability of the code to carry out long-term accurate evolutions of the linear and nonlinear dynamics of isolated relativistic stars.

  3. Reentrance and ultrametricity in three-dimensional Ising spin glasses

    Science.gov (United States)

    Katzgraber, Helmut G.; Thomas, Creighton K.; Hartmann, Alexander K.

    2012-02-01

    We study the three-dimensional Edwards-Anderson Ising spin glass with bimodal disorder with a fraction of 22.8% antiferromagnetic bonds. Parallel tempering Monte Carlo simulations down to very low temperatures show that for this fraction of antiferromagnetic bonds the phase diagram of the system is reentrant, in agreement with previous results. Furthemore, using a clustering analysis, we analyze the ultrametric properties of phase space for this model.

  4. Strategy for automatic and complete three-dimensional optical digitization

    OpenAIRE

    2012-01-01

    This Letter proposes a new strategy of a three-dimensional (3D) scanning pipeline to achieve complete 3D digitization of complex objects in a real scene. This strategy consists of a one-dimensional array of optical 3D sensors combined with an automatically controlled turntable. An efficient calibration method for the sensor array is presented to guarantee the accuracy of the 3D measurement. Furthermore, an automatic registration technique is also proposed for aligning multiple range images ta...

  5. Entropy of three-dimensional BTZ black holes

    Institute of Scientific and Technical Information of China (English)

    GAO; Changjun; SHEN; Yougen

    2004-01-01

    The entropies of scalar field and neutrino field are calculated in the back ground of three-dimensional BTZ black hole.Considering statistical physics,we propose not to consider the superraradiant modes for bosons(Fermion fields do not displaysup perradiance).In fact,the nonsuperradiant modes do contribute exactly the area entropy for both bosons and fermions.The result shows that the neutrino field entropy is 3/2 times the scalar one.

  6. Three-Dimensional Simulations of Deep-Water Breaking Waves

    CERN Document Server

    Brucker, Kyle A; Dommermuth, Douglas G; Adams, Paul

    2014-01-01

    The formulation of a canonical deep-water breaking wave problem is introduced, and the results of a set of three-dimensional numerical simulations for deep-water breaking waves are presented. In this paper fully nonlinear progressive waves are generated by applying a normal stress to the free surface. Precise control of the forcing allows for a systematic study of four types of deep-water breaking waves, characterized herein as weak plunging, plunging, strong plunging, and very strong plunging.

  7. Development of three-dimensional memory (3D-M)

    Science.gov (United States)

    Yu, Hong-Yu; Shen, Chen; Jiang, Lingli; Dong, Bin; Zhang, Guobiao

    2016-10-01

    Since the invention of 3-D ROM in 1996, three-dimensional memory (3D-M) has been under development for nearly two decades. In this presentation, we'll review the 3D-M history and compare different 3D-Ms (including 3D-OTP from Matrix Semiconductor, 3D-NAND from Samsung and 3D-XPoint from Intel/Micron).

  8. Three dimensional momentum distributions of recoil-ions and photoelectrons

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, J.; Schmitt, W. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Doerner, R.; Jagutzki, O.; Mergel, V.; Moshammer, R.; Schmidt-Boecking, H.; Spielberger, L.; Unverzagt, M.; Vogt, T. [Frankfurt Univ. (Germany). Inst. fuer Kernphysik

    1996-10-01

    A novel high-resolution technique, the Multi-Electron-Recoil-Ion Momentum Spectroscopy, allows to determine in coincidence the three dimensional momentum vectors of the ion and up to three electrons created in any photo ionization event. At a solid angle of 4 {pi} the energy-resolutions for ions and electrons are {+-}2{mu} eV and {+-}10 meV, respectively. (orig.)

  9. Three-dimensional surface reconstruction from multistatic SAR images.

    Science.gov (United States)

    Rigling, Brian D; Moses, Randolph L

    2005-08-01

    This paper discusses reconstruction of three-dimensional surfaces from multiple bistatic synthetic aperture radar (SAR) images. Techniques for surface reconstruction from multiple monostatic SAR images already exist, including interferometric processing and stereo SAR. We generalize these methods to obtain algorithms for bistatic interferometric SAR and bistatic stereo SAR. We also propose a framework for predicting the performance of our multistatic stereo SAR algorithm, and, from this framework, we suggest a metric for use in planning strategic deployment of multistatic assets.

  10. Sectional and Ricci Curvature for Three-Dimensional Lie Groups

    Directory of Open Access Journals (Sweden)

    Gerard Thompson

    2016-01-01

    Full Text Available Formulas for the Riemann and Ricci curvature tensors of an invariant metric on a Lie group are determined. The results are applied to a systematic study of the curvature properties of invariant metrics on three-dimensional Lie groups. In each case the metric is reduced by using the automorphism group of the associated Lie algebra. In particular, the maximum and minimum values of the sectional curvature function are determined.

  11. THE SYSTEM SIMULATION OF THREE-DIMENSIONAL RADAR

    Institute of Scientific and Technical Information of China (English)

    Zhang Wei; Xiang Jingcheng; Wang Xuegang

    2004-01-01

    To provide a test platform for Electronic Warfare (EW) system, it is needed to simulate the radar received Intermediate Frequency (IF) signals and radar system functions.This letter gives a description of a radar system simulation software developed for frequencyphase scanning three-dimensional (3-D) radar. Experimental results prove that the software could be used for system evaluation and for training purposes as an attractive alternative to real EW system.

  12. IF signals simulation of three-dimensional radar

    Institute of Scientific and Technical Information of China (English)

    Zhang Wei; Wang Xuegang; Zhu Zhaoda

    2008-01-01

    Based on the analysis of the principles of frequency-phase scanning 3-D (three-dimensional) radar and the scattering mechanism of 3-D radar, the target and clutter IF (intermediate frequency) signals model of frequencyphase scanning 3-D radar is presented. The IF signals model of different channels of 3-D radar is presented in one simple formula in which complex waveform effects are considered. The simulation results obtained during tests are also provided in the end.

  13. Electric transport in three-dimensional Skyrmion/monopole crystal

    OpenAIRE

    Zhang, Xiao-Xiao; Mishchenko, Andrey S.; De Filippis, Giulio; Nagaosa, Naoto

    2016-01-01

    We study theoretically the transport properties of a three-dimensional spin texture made from three orthogonal helices, which is essentially a lattice of monopole-antimonopole pairs connected by Skyrmion strings. This spin structure is proposed for MnGe based on the neutron scattering experiment as well as the Lorentz transmission electron microscopy observation. Equipped with a sophisticated spectral analysis method, we adopt finite temperature Green's function technique to calculate the lon...

  14. Three-dimensional nonparaxial beams in parabolic rotational coordinates.

    Science.gov (United States)

    Deng, Dongmei; Gao, Yuanmei; Zhao, Juanying; Zhang, Peng; Chen, Zhigang

    2013-10-01

    We introduce a class of three-dimensional nonparaxial optical beams found in a parabolic rotational coordinate system. These beams, representing exact solutions of the nonparaxial Helmholtz equation, have inherent parabolic symmetries. Assisted with a computer-generated holography, we experimentally demonstrate the generation of different modes of these beams. The observed transverse beam patterns along the propagation direction agree well with those from our theoretical predication.

  15. A practical three-dimensional dosimetry system for radiation therapy

    OpenAIRE

    Guo, Pengyi; Adamovics, John; Oldham, Mark

    2006-01-01

    There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE™) and a commercial optical computed tomography (CT) scanning system (OCTOPUS™). PRESAGE™ is a transparent material with com...

  16. Three-dimensional conceptual model for service-oriented simulation

    CERN Document Server

    Wang, Wenguang; Zander, Justyna; Zhu, Yifan; 10.1631/jzus.A0920258

    2009-01-01

    In this letter, we propose a novel three-dimensional conceptual model for an emerging service-oriented simulation paradigm. The model can be used as a guideline or an analytic means to find the potential and possible future directions of the current simulation frameworks. In particular, the model inspects the crossover between the disciplines of modeling and simulation, service-orientation, and software/systems engineering. Finally, two specific simulation frameworks are studied as examples.

  17. Three-Dimensional DNA Nanostructures Assembled from DNA Star Motifs.

    Science.gov (United States)

    Tian, Cheng; Zhang, Chuan

    2017-01-01

    Tile-based DNA self-assembly is a promising method in DNA nanotechnology and has produced a wide range of nanostructures by using a small set of unique DNA strands. DNA star motif, as one of DNA tiles, has been employed to assemble varieties of symmetric one-, two-, three-dimensional (1, 2, 3D) DNA nanostructures. Herein, we describe the design principles, assembly methods, and characterization methods of 3D DNA nanostructures assembled from the DNA star motifs.

  18. On a three-dimensional implementation of the baker's transformation

    Science.gov (United States)

    Carrière, Philippe

    2007-11-01

    A three-dimensional, steady flow configuration intended to mimic the baker's map is studied by means of numerical simulation. The Poincaré sections computed from a finite element solution of the velocity field show that the behavior is dominated by chaotic advection. The value obtained for the Lyapunov exponent is very close to the theoretical value of ln2 predicted by the baker's map.

  19. Powder blasting for three-dimensional microstructuring of glass

    OpenAIRE

    Belloy, E.; Sayah, A.; M.A.M. Gijs

    2000-01-01

    We report on powder blasting as a promising technology for the three-dimensional structuring of brittle materials. We investigate the basic parameters of this process, which is based on the erosion of a masked substrate by a high-velocity eroding powder beam, using glass substrates. We study the effect of various parameters on the etching rate, like the powder velocity and the mask feature size, which induces geometrical effects to the erosion process. We introduce oblique powder blasting and...

  20. Three-dimensional magnetic recording using ferromagnetic resonance

    Science.gov (United States)

    Suto, Hirofumi; Kudo, Kiwamu; Nagasawa, Tazumi; Kanao, Taro; Mizushima, Koichi; Sato, Rie

    2016-07-01

    To meet the ever-increasing demand for data storage, future magnetic recording devices will need to be made three-dimensional by implementing multilayer recording. In this article, we present methods of detecting and manipulating the magnetization direction of a specific layer selectively in a vertically stacked multilayer magnetic system, which enable layer-selective read and write operations in three-dimensional magnetic recording devices. The principle behind the methods is ferromagnetic resonance excitation in a microwave magnetic field. By designing each magnetic recording layer to have a different ferromagnetic resonance frequency, magnetization excitation can be induced individually in each layer by tuning the frequency of an applied microwave magnetic field, and this selective magnetization excitation can be utilized for the layer-selective operations. Regarding media for three-dimensional recording, when layers of a perpendicular magnetic material are vertically stacked, dipolar interaction between multiple recording layers arises and is expected to cause problems, such as degradation of thermal stability and switching field distribution. To solve these problems, we propose the use of an antiferromagnetically coupled structure consisting of hard and soft magnetic layers. Because the stray fields from these two layers cancel each other, antiferromagnetically coupled media can reduce the dipolar interaction.

  1. Three dimensional self-assembly at the nanoscale

    Science.gov (United States)

    Gracias, D. H.

    2013-05-01

    At the nanoscale, three dimensional manipulation and assembly becomes extremely challenging and also cost prohibitive. Self-assembly provides an attractive and possibly the only highly parallel methodology to structure truly three dimensional patterned materials and devices at this size scale for applications in electronics, optics, robotics and medicine. This is a concise review along with a perspective of an important and exciting field in nanotechnology and is related to a Nanoengineering Pioneer Award that I received at this SPIE symposium for my contributions to the 3D selfassembly of nanostructures. I detail a historical account of 3D self-assembly and outline important developments in this area which is put into context with the larger research areas of 3D nanofabrication, assembly and nanomanufacturing. A focus in this review is on our work as it relates to the self-assembly with lithographically patterned units; this approach provides a means for heterogeneous integration of periodic, curved and angled nanostructures with precisely defined three dimensional patterns.

  2. Interaction of two three-dimensional explosion bubbles

    Institute of Scientific and Technical Information of China (English)

    YAO Xiong-liang; ZHANG A-man; LIU Yu-chen

    2007-01-01

    The interaction of two underwater explosion bubbles was mathematically analyzed in this paper. Based on the assumption of potential flow, high-order curved elements were used to discretize the boundary integral equation and solve it. Assuming that gas inside the bubble follows the isentropic rule,the Euler-Lagrange method was used to trace the evolution of the bubble, and when calculating the singular integral, the singularity of the double-layer singular integral was eliminated by reconstructing a principal-value integral of double-layer potential so that a more precise result could be obtained. Elastic mesh technique (EMT) was also used when tracing the evolution of the bubble interface, and numerical smoothing wasn't needed. A comparison of calculations using this three-dimensional model with results of the Reyleigh-Plesset bubble model shows that the three-dimensional model and calculation method in this paper is practical. This three-dimensional model was applied to simulate the interaction of two bubbles under the action of gravity, and the dynamic characteristics of two bubbles near the surface was also analyzed. Bubbles influenced by surface effects and gravity present severe non-linearity. This paper provides a reference for research into the dynamics of multi-bubbles.

  3. Three-dimensional illumination system for tomographic particle image velocimetry

    Science.gov (United States)

    Zhang, Fen; Song, Yang; Qu, Xiangju; Ji, Yunjing; Li, Zhenhua; He, Anzhi

    2016-10-01

    Tomographic particle image velocimetry (Tomo-PIV) is a new developed technique for three-component threedimensional (3C-3D) velocity measurement of the flow field based on the optical tomographic reconstruction method, and has been received extensive attention of the related industries. Three-dimensional light source illuminating the tracer particles of flow field is a critical application for tomographic particle image velocimetry. Three-dimensional light source not only determines the size of measurement volume and the range of the scope of application, but also has a great influence on the image quality. In this work, we propose a rectangular light amplification system using powell lens, prisms and two reflectors. The system can be optimized if given the system parameters based on the theoretical model. The rectangular light amplification system will be verified experimentally by measuring the cross section size of the illuminated light source. A 60mm×25mm cross section of rectangular three-dimensional light source can be obtained by using the rectangular light amplification system. The experiments demonstrate the the feasibility the proposed system.

  4. Three-dimensional robust diving guidance for hypersonic vehicle

    Science.gov (United States)

    Zhu, Jianwen; Liu, Luhua; Tang, Guojian; Bao, Weimin

    2016-01-01

    A novel three-dimensional robust guidance law based on H∞ filter and H∞ control is proposed to meet the constraints of the impact accuracy and the flight direction under process disturbances for the dive phase of hypersonic vehicle. Complete three-dimensional coupling relative motion equations are established and decoupled into linear ones by feedback linearization to simplify the design process of the further guidance law. Based on the linearized equations, H∞ filter is introduced to eliminate the measurement noises of line-of-sight angles and estimate the angular rates. Furthermore, H∞ robust control is well employed to design guidance law, and the filtered information is used to generate guidance commands to meet the guidance goal accurately and robustly. The simulation results of CAV-H indicate that the proposed three-dimensional equations can describe the coupling character more clearly than the traditional decoupling guidance, and the proposed guidance strategy can guide the vehicle to satisfy different multiple constraints with high accuracy and robustness.

  5. Three-dimensional laser window formation for industrial application

    Science.gov (United States)

    Verhoff, Vincent G.; Kowalski, David

    1993-01-01

    The NASA Lewis Research Center has developed and implemented a unique process for forming flawless three-dimensional, compound-curvature laser windows to extreme accuracies. These windows represent an integral component of specialized nonintrusive laser data acquisition systems that are used in a variety of compressor and turbine research testing facilities. These windows are molded to the flow surface profile of turbine and compressor casings and are required to withstand extremely high pressures and temperatures. This method of glass formation could also be used to form compound-curvature mirrors that would require little polishing and for a variety of industrial applications, including research view ports for testing devices and view ports for factory machines with compound-curvature casings. Currently, sodium-alumino-silicate glass is recommended for three-dimensional laser windows because of its high strength due to chemical strengthening and its optical clarity. This paper discusses the main aspects of three-dimensional laser window formation. It focuses on the unique methodology and the peculiarities that are associated with the formation of these windows.

  6. Formation of three-dimensional Parylene C structures via thermoforming

    Science.gov (United States)

    Kim, B. J.; Chen, B.; Gupta, M.; Meng, E.

    2014-06-01

    The thermoplastic nature of Parylene C is leveraged to enable the formation of three-dimensional structures using a thermal forming (thermoforming) technique. Thermoforming involves the heating of Parylene films above its glass transition temperature while they are physically confined in the final desired conformation. Micro and macro scale three-dimensional structures composed of Parylene thin films were developed using the thermoforming process, and the resulting chemical and mechanical changes to the films were characterized. No large changes to the surface and bulk chemistries of the polymer were observed following the thermoforming process conducted in vacuum. Heat treated structures exhibited increased stiffness by a maximum of 37% depending on the treatment temperature, due to an increase in crystallinity of the Parylene polymer. This study revealed important property changes resulting from the process, namely (1) the development of high strains in thermoformed areas of small radii of curvature (30-90 µm) and (2) ˜1.5% bulk material shrinkage in thermoformed multilayered Parylene-Parylene and Parylene-metal-Parylene films. Thermoforming is a simple process whereby three-dimensional structures can be achieved from Parylene C-based thin film structures with tunable mechanical properties as a function of treatment temperature.

  7. Springback prediction of three-dimensional variable curvature tube bending

    Directory of Open Access Journals (Sweden)

    Shen Zhang

    2016-03-01

    Full Text Available The springback phenomenon of tube bending occurs consequentially after unloading, which will affect the manufacturing accuracy and processing efficiency of the tubular products. In this article, the bending and springback processes of minor-diameter thick-walled tube are simulated by ABAQUS to reveal the springback laws. The springback prediction of three-dimensional variable curvature bent tube is projected on each discrete osculating and rectifying plane, and then the three-dimensional problem can be transformed into two dimensions. The mathematic relationship of the radius before and after springback in the plane is built by approximate pure bending springback experiments. The springback on such planes is transformed into three dimensions. The tube axes are merged by first-order geometric (G1 continuity and then compensated with the modified function according to the axis complexity, so as to establish mathematic analytic model for springback prediction of three-dimensional variable curvature tube bending. Finally, the feasibility, reliability, and accuracy of the model are verified by finite element method and experiments.

  8. Three dimensional modelling of ICRF launchers for fusion devices

    Science.gov (United States)

    Carter, M. D.; Rasmussen, D. A.; Ryan, P. M.; Hanson, G. R.; Stallings, D. C.; Batchelor, D. B.; Bigelow, T. S.; England, A. C.; Hoffman, D. J.; Murakami, M.; Wang, C. Y.; Wilgen, J. B.; Rogers, J. H.; Wilson, J. R.; Majeski, R.; Schilling, G.

    1996-02-01

    The three dimensional (3-D) nature of antennas for fusion applications in the ion cyclotron range of frequencies (ICRF) requires accurate modelling to design and analyse new antennas. In this article, analysis and design tools for radiofrequency (RF) antennas are successfully benchmarked with experiment, and the 3-D physics of the launched waves is explored. The systematic analysis combines measured density profiles from a reflectometer system, transmission line circuit modelling, detailed 3-D magnetostatics modelling and a new 3-D electromagnetic antenna model including plasma. This analysis gives very good agreement with measured loading data from the Tokamak Fusion Test Reactor (TFTR) Bay-M antenna, thus demonstrating the validity of the analysis for the design of new RF antennas. The 3-D modelling is contrasted with 2-D models, and significant deficiencies are found in the latter. The 2-D models are in error by as much as a factor of 2 in real and reactive loading, even after they are corrected for the most obvious 3-D effects. Three dimensional effects play the most significant role at low parallel wavenumbers, where the launched power spectrum can be quite different from the predictions of 2-D models. Three dimensional effects should not be ignored for many RF designs, especially those intended for fast wave current drive

  9. Clinical Stress Echocardiography

    NARCIS (Netherlands)

    S.E. Karagiannis

    2007-01-01

    textabstractTwo-dimensional echocardiography is a commonly used non-invasive method for the assessment of left ventricular function. It provides precise information on both global and segmental myocardial function by displaying endocardial motion and wall thickening. Dobutamine stress

  10. Three-dimensional appearance of the lips muscles with three-dimensional isotropic MRI: in vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Raphael; Reychler, H. [Universite Catholique de Louvain, Department of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Brussels (Belgium); Liu, Y.; Xu, T.M. [Peking University School and Hospital of Stomatology, Department of Orthodontics, Beijing (China); Duprez, T. [Universite Catholique de Louvain, Department of Radiology, Cliniques Universitaires Saint Luc, Brussels (Belgium)

    2009-06-15

    Our knowledge of facial muscles is based primarily on atlases and cadaveric studies. This study describes a non-invasive in vivo method (3D MRI) for segmenting and reconstructing facial muscles in a three-dimensional fashion. Three-dimensional (3D), T1-weighted, 3 Tesla, isotropic MRI was applied to a subject. One observer performed semi-automatic segmentation using the Editor module from the 3D Slicer software (Harvard Medical School, Boston, MA, USA), version 3.2. We were able to successfully outline and three-dimensionally reconstruct the following facial muscles: pars labialis orbicularis oris, m. levatro labii superioris alaeque nasi, m. levator labii superioris, m. zygomaticus major and minor, m. depressor anguli oris, m. depressor labii inferioris, m. mentalis, m. buccinator, and m. orbicularis oculi. 3D reconstruction of the lip muscles should be taken into consideration in order to improve the accuracy and individualization of existing 3D facial soft tissue models. More studies are needed to further develop efficient methods for segmentation in this field. (orig.)

  11. Changes in three-dimensional speckle-tracking-derived myocardial strain during percutaneous coronary intervention.

    Science.gov (United States)

    Ternacle, Julien; Gallet, Romain; Champagne, Stéphane; Teiger, Emmanuel; Gellen, Barnabas; Dubois Randé, Jean-Luc; Gueret, Pascal; Lim, Pascal

    2013-12-01

    The aim of this study was to evaluate changes in three-dimensional (3D) speckle-tracking-derived myocardial strain during ischemia. Twenty patients referred for percutaneous coronary intervention were studied (mean age, 65 ± 11 years; mean left ventricular ejection fraction, 56 ± 7%). Of the 20 study patients, 12 had severe left anterior descending coronary artery stenosis. A full-volume apical view using multibeat 3D modality and two-dimensional (2D) apical views (four chamber, two chamber, and three chamber) were recorded during coronary occlusion before wall motion abnormalities. After percutaneous coronary intervention, ultrasound contrast agent was selectively delivered through the target lesion to delineate ischemic and peri-ischemic segments (ischemia-adjacent segments). Strain values derived from 2D and 3D speckle-tracking echocardiography were compared in ischemic and nonischemic segments. Despite no changes in wall motion and 2D left ventricular ejection fraction (56 ± 7% vs 56 ± 7%), global longitudinal strain by 2D imaging was impaired during percutaneous coronary intervention (-16 ± 3% vs -14 ± 3%, P = .01). Similar changes were observed for all 3D strain components: -11 ± 16% for longitudinal (-15 ± 4% vs -13 ± 4%, P = .03), -13 ± 25% for circumferential (-15 ± 4% vs -12 ± 4%, P = .02), -12 ± 16% for area (-25 ± 5% vs -22 ± 6%, P = .009), and -12 ± 25% for radial global strain (39 ± 12% vs 33 ± 12%, P = .04). During coronary occlusion, 2D longitudinal peak strain and all 3D peak strain components decreased in ischemic segments, while no changes was observed in nonischemic segments. In peri-ischemic segments, only 3D longitudinal and area strain were impaired during ischemia. Changes in myocardial deformation related to ischemia can be characterized by 3D speckle-tracking echocardiography before the stage of wall motion abnormality. Copyright © 2013 American Society of

  12. Parallax scanning methods for stereoscopic three-dimensional imaging

    Science.gov (United States)

    Mayhew, Christopher A.; Mayhew, Craig M.

    2012-03-01

    Under certain circumstances, conventional stereoscopic imagery is subject to being misinterpreted. Stereo perception created from two static horizontally separated views can create a "cut out" 2D appearance for objects at various planes of depth. The subject volume looks three-dimensional, but the objects themselves appear flat. This is especially true if the images are captured using small disparities. One potential explanation for this effect is that, although three-dimensional perception comes primarily from binocular vision, a human's gaze (the direction and orientation of a person's eyes with respect to their environment) and head motion also contribute additional sub-process information. The absence of this information may be the reason that certain stereoscopic imagery appears "odd" and unrealistic. Another contributing factor may be the absence of vertical disparity information in a traditional stereoscopy display. Recently, Parallax Scanning technologies have been introduced, which provide (1) a scanning methodology, (2) incorporate vertical disparity, and (3) produce stereo images with substantially smaller disparities than the human interocular distances.1 To test whether these three features would improve the realism and reduce the cardboard cutout effect of stereo images, we have applied Parallax Scanning (PS) technologies to commercial stereoscopic digital cinema productions and have tested the results with a panel of stereo experts. These informal experiments show that the addition of PS information into the left and right image capture improves the overall perception of three-dimensionality for most viewers. Parallax scanning significantly increases the set of tools available for 3D storytelling while at the same time presenting imagery that is easy and pleasant to view.

  13. Three-dimensional stochastic seepage field for embankment engineering

    Directory of Open Access Journals (Sweden)

    Ya-jun WANG

    2009-03-01

    Full Text Available Owing to the complexity of geo-engineering seepage problems influenced by different random factors, three-dimensional simulation and analysis of the stochastic seepage field plays an important role in engineering applications. A three-dimensional anisotropic heterogeneous steady random seepage model was developed on the basis of the finite element method. A statistical analysis of the distribution characteristics of soil parameters sampled from the main embankment of the Yangtze River in the Southern Jingzhou zone of China was conducted. The Kolomogorov-Smirnov test verified the statistical hypothesis that the permeability coefficient tensor has a Gaussian distribution. With the help of numerical analysis of the stochastic seepage field using the developed model, various statistical and random characteristics of the stochastic seepage field of the main embankment of the Yangtze River in the Southern Jingzhou zone of China were investigated. The model was also examined with statistical testing. Through the introduction of random variation of the upstream and downstream water levels into the model, the effects of the boundary randomness due to variation of the downstream and upstream water levels on the variation of simulated results presented with a vector series of the random seepage field were analyzed. Furthermore, the combined influence of the variation of the soil permeability coefficient and such seepage resistance measures as the cut-off wall and relief ditch on the hydraulic head distribution was analyzed and compared with the results obtained by determinate analysis. Meanwhile, sensitivities of the hydraulic gradient and downstream exit height to the variation of boundary water level were studied. The validity of the simulated results was verified by stochastic testing and measured data. The developed model provides more detail and a full stochastic algorithm to characterize and analyze three-dimensional stochastic seepage field problems

  14. Three-dimensional stochastic seepage field for embankment engineering

    Institute of Scientific and Technical Information of China (English)

    Ya-jun WANG; Wo-hua ZHANG; Chang-yu WU; Da-chun REN

    2009-01-01

    Owing to the complexity of get-engineering seepage problems influenced by different random factors, three-dimensional simulation and analysis of the stochastic seepage field plays an important role in engineering applications. A three-dimensional anisotropic heterogeneous steady random seepage model was developed on the basis of the finite element method. A statistical analysis of the distribution characteristics of soil parameters sampled from the main embankment of the Yangtze River in the Southern Jingzhou zone of China was conducted. The Kolomogorov-Smimov test verified the statistical hypothesis that the permeability coefficient tensor has a Gaussian distribution. With the help of numerical analysis of the stochastic seepage field using the developed model, various statistical and random characteristics of the stochastic seepage field of the main embankment of the Yangtze River in the Southern Jingzhou zone of China were investigated. The model was also examined with statistical testing. Through the introduction of random variation of the upstream and downstream water levels into the model, the effects of the boundary randomness due to variation of the downstream and upstream water levels on the variation of simulated results presented with a vector series of the random seepage field were analyzed. Furthermore, the combined influence of the variation of the soil permeability coefficient and such seepage resistance measures as the cut-off wall and relief ditch on the hydraulic head distribution was analyzed and compared with the results obtained by determinate analysis. Meanwhile, sensitivities of the hydraulic gradient and downstream exit height to the variation of boundary water level were studied. The validity of the simulated results was verified by stochastic testing and measured data. The developed model provides more detail and a full stochastic algorithm to characterize and analyze three-dimensional stochastic seepage field problems.

  15. Three-dimensional numerical modeling of nearshore circulation

    Institute of Scientific and Technical Information of China (English)

    SUN Detong

    2008-01-01

    A three-dimensional nearshore circulation model was developed by coupling CH3D, a three-dimensional hydrodynamic model and REF/DIF, a nearsbore wave transformation model. The model solves the three-dimensional wave-averaged equations of motion. Wave-induced effects on circulation were introduced in the form of radiation stresses, wave-induced mass transport, wave-induced enhancement of bottom friction and wave-induced turbulent mixing. Effects of breaking waves were considered following Svendsen (1984a and 1984b) and Stive and Wind (1986). The model was successfully tested against the analytical solution of longshore currents by Longuet and Higgins (1970). The model successfully simulated the undertow as observed in a laboratory experiment by Stive and Wind (1982). In addition, the model was applied to a physical model by Mory and Hamm (1997) and successfully reproduced the eddy behind a detached breakwater as well as the longshore current on the open beach and the contiguous eddy in the open area of the wave tank. While the qualitative agreement between model results and experimental observations was very good, the quantitative agreement needs to be further improved. Albeit difficult to explain every discrepancy between the model re- suits and observations, in general, sources of errors are attributed to the lack of understanding and comprehensive description of following processes: (1) the horizontal and vertical distribution of radiation stress, especially for breaking waves; (2) the detailed structure of turbulence;(3)Wave-current interaction (not included at this moment) ; and (4)the wave- current boundary layer and the resulting bottom shear stress.

  16. Three-dimensional visual illusion of graphic painting

    Institute of Scientific and Technical Information of China (English)

    于静

    2012-01-01

    Visual illusion is the visual design of a special category.It is a set of technology and art in one of a unique form of artistic expression.Visual illusion can give people a taste of the spirit, with strong cultural con- tent and artistic appeal.So by this way of painting, it has a clever and unique perspective. Aspect If the plane can be realistic paintings to life, then the three-dimensional, two-dimensional space can be called even more powerful by aspects.

  17. Three-dimensional reconstruction of the rat nephron

    DEFF Research Database (Denmark)

    Christensen, Erik Ilsø; Grann, Birgitte; Kristoffersen, Inger B.;

    2014-01-01

    This study gives a three-dimensional (3D) structural analysis of rat nephrons and their connections to collecting ducts. Approximately 4,500 2.5-μm-thick serial sections from the renal surface to the papillary tip were obtained from each of 3 kidneys of Wistar rats. Digital images were recorded...... and aligned into three image stacks and traced from image to image. Short-loop nephrons (SLNs), long-loop nephrons (LLNs), and collecting ducts (CDs) were reconstructed in 3D. We identified a well-defined boundary between the outer stripe and the inner stripe of the outer medulla corresponding...

  18. Integrated three-dimensional reconstruction using reflectance fields

    Directory of Open Access Journals (Sweden)

    Maria-Luisa Rosas

    2012-01-01

    Full Text Available A method to obtain three-dimensional data of real-world objects by integrating their material properties is presented. The material properties are defined by capturing the Reflectance Fields of the real-world objects. It is shown, unlike conventional reconstruction methods, the method is able to use the reflectance information to recover surface depth for objects having a non-Lambertian surface reflectance. It is, for recovering 3D data of objects exhibiting an anisotropic BRDF with an error less than 0.3%.

  19. Three-dimensional imaging for a very large excavator

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, J.; Winstanley, G.; Corke, P. [CSIRO, Kenmore, Qld. (Australia). Manufacture and & Infrastructure Technology

    2003-08-01

    We describe the development of a three-dimensional (3D) imaging system for a 3500 tonne mining machine (dragline). Draglines are large walking cranes used for removing the dirt that covers a coal seam. Our group has been developing a dragline swing automation system since 1994. The system so far has been 'blind' to its external environment. The work presented in this paper attempts to give the dragline an ability to sense its surroundings. A 3D digital terrain map (DTM) is created from data obtained from a two-dimensional laser scanner while the dragline swings. Experimental data from an operational dragline are presented.

  20. New Discrete Element Models for Three-Dimensional Impact Problems

    Institute of Scientific and Technical Information of China (English)

    SHAN Li; CHENG Ming; LIU Kai-xin; LIU Wei-Fu; CHEN Shi-Yang

    2009-01-01

    Two 3-D numerical models of the discrete element method(DEM)for impact problems are proposed.The models can calculate not only the impact problems of continuum and non-continuum,but also the transient process from continuum to non-continuum.The stress wave propagation in a concrete block and a dynamic splitting process of a marble disc under impact loading are numerically simulated with the proposed models.By comparing the numerical results with the corresponding results obtained by the finite element method(FEM)and the experiments,it is proved that the models are reliable for three-dimensional impact problems.

  1. Three-dimensional versus two-dimensional vision in laparoscopy

    DEFF Research Database (Denmark)

    Sørensen, Stine Maya Dreier; Savran, Mona M; Konge, Lars;

    2016-01-01

    BACKGROUND: Laparoscopic surgery is widely used, and results in accelerated patient recovery time and hospital stay were compared with laparotomy. However, laparoscopic surgery is more challenging compared with open surgery, in part because surgeons must operate in a three-dimensional (3D) space...... through a two-dimensional (2D) projection on a monitor, which results in loss of depth perception. To counter this problem, 3D imaging for laparoscopy was developed. A systematic review of the literature was performed to assess the effect of 3D laparoscopy. METHODS: A systematic search of the literature...

  2. CATIA Core Tools Computer Aided Three-Dimensional Interactive Application

    CERN Document Server

    Michaud, Michel

    2012-01-01

    CATIA Core Tools: Computer-Aided Three-Dimensional Interactive Application explains how to use the essential features of this cutting-edge solution for product design and innovation. The book begins with the basics, such as launching the software, configuring the settings, and managing files. Next, you'll learn about sketching, modeling, drafting, and visualization tools and techniques. Easy-to-follow instructions along with detailed illustrations and screenshots help you get started using several CATIA workbenches right away. Reverse engineering--a valuable product development skill--is also covered in this practical resource.

  3. Three dimensional free convection couette flow with transpiration cooling

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Free convection flow between two vertical parallel plates with transverse sinusoidal injection of the fluid at the stationary plate and its corresponding removal by constant suction through the plate in uniform motion has been analyzed. Due to this type of injection velocity, the flow becomes three-dimensional. Analytical expressions for the velocity, temperature, skin friction and rate of heat transfer were obtained. The important characteristics of the problem, namely the skin friction and the rate of heat transfer are discussed in detail with the help of graphs.

  4. The Electron in Three-Dimensional Momentum Space

    Science.gov (United States)

    Mantovani, L.; Bacchetta, A.; Pasquini, B.

    2016-07-01

    We study the electron as a system composed of an electron and a photon and derive the leading-twist transverse-momentum-dependent distribution functions for both the electron and photon in the dressed electron, thereby offering a three-dimensional description of the dressed electron in momentum space. To obtain the distribution functions, we apply both the formalism of light-front wave function overlap representation and the diagrammatic approach; we discuss the comparison of our results between light-cone gauge and Feynman gauge, discussing the role of the Wilson lines to obtain gauge-independent results. We provide examples of plots of the computed distributions.

  5. Three-dimensional characterization of stress corrosion cracks

    DEFF Research Database (Denmark)

    Lozano-Perez, S.; Rodrigo, P.; Gontard, Lionel Cervera

    2011-01-01

    Understanding crack propagation and initiation is fundamental if stress corrosion cracking (SCC) mechanisms are to be understood. However, cracking is a three-dimensional (3D) phenomenon and most characterization techniques are restricted to two-dimensional (2D) observations. In order to overcome...... the best spatial resolution. To illustrate the power of these techniques, different parts of dominant stress corrosion cracks in Ni-alloys and stainless steels have been reconstructed in 3D. All relevant microstructural features can now be studied in detail and its relative orientation respect...

  6. The three-dimensional crystal structure of cholera toxin

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Rong-Guang; Westbrook, M.L.; Nance, S.; Spangler, B.D. [Argonne National Lab., IL (United States); Scott, D.L. [Yale Univ., New Haven, CT (United States). Dept. of Molecular Biophysics and Biochemistry; Westbrook, E.M. [Northwestern Univ., Evanston, IL (United States)

    1996-02-01

    The clinical manifestations of cholera are largely attributable to the actions of a secreted hexameric AB{sub 5} enterotoxin (choleragen). We have solved the three-dimensional structure of choleragen at 2.5 {Angstrom} resolution and compared the refined coordinates with those of choleragenoid (isolated B pentamer) and the heat-labile enterotoxin from Escherichia coli (LT). The crystalline coordinates provide a detailed view of the stereochemistry implicated in binding to GM1 gangliosides and in carrying out ADP-ribosylation. The A2 chain of choleragen, in contrast to that of LT, is a nearly continuous {alpha}-helix with an interpretable carboxyl tail.

  7. Integrating three-dimensional printing and nanotechnology for musculoskeletal regeneration

    Science.gov (United States)

    Nowicki, Margaret; Castro, Nathan J.; Rao, Raj; Plesniak, Michael; Zhang, Lijie Grace

    2017-09-01

    The field of tissue engineering is advancing steadily, partly due to advancements in rapid prototyping technology. Even with increasing focus, successful complex tissue regeneration of vascularized bone, cartilage and the osteochondral interface remains largely illusive. This review examines current three-dimensional printing techniques and their application towards bone, cartilage and osteochondral regeneration. The importance of, and benefit to, nanomaterial integration is also highlighted with recent published examples. Early-stage successes and challenges of recent studies are discussed, with an outlook to future research in the related areas.

  8. Methods for preparation of three-dimensional bodies

    Energy Technology Data Exchange (ETDEWEB)

    Mulligan, Anthony C [Tucson, AZ; Rigali, Mark J [Carlsbad, NM; Sutaria, Manish P [Malden, MA; Artz, Gregory J [Tucson, AZ; Gafner, Felix H [Tucson, AZ; Vaidyanathan, K Ranji [Tucson, AZ

    2008-06-17

    Processes for mechanically fabricating two and three-dimensional fibrous monolith composites include preparing a fibrous monolith filament from a core composition of a first powder material and a boundary material of a second powder material. The filament includes a first portion of the core composition surrounded by a second portion of the boundary composition. One or more filaments are extruded through a mechanically-controlled deposition nozzle onto a working surface to create a fibrous monolith composite object. The objects may be formed directly from computer models and have complex geometries.

  9. Critical exponents of a three dimensional O(4) spin model

    CERN Document Server

    Kanaya, K; Kanaya, K; Kaya, S

    1995-01-01

    By Monte Carlo simulation we study the critical exponents governing the transition of the three-dimensional classical O(4) Heisenberg model, which is considered to be in the same universality class as the finite-temperature QCD with massless two flavors. We use the single cluster algorithm and the histogram reweighting technique to obtain observables at the critical temperature. After estimating an accurate value of the inverse critical temperature \\Kc=0.9360(1) we make non-perturbative estimates for various critical exponents by finite-size scaling analysis. They are in excellent agreement with those obtained with the 4-\\epsilon expansion method with errors reduced to about halves of them.

  10. Complete wetting in the three-dimensional transverse Ising model

    Science.gov (United States)

    Harris, A. B.; Micheletti, C.; Yeomans, J. M.

    1996-08-01

    We consider a three-dimensional Ising model in a transverse magnetic field h and a bulk field H. An interface is introduced by an appropriate choice of boundary conditions. At the point ( H=0, h=0) spin configurations corresponding to different positions of the interface are degenerate. By studying the phase diagram near this multiphase point using quantum mechanical perturbation theory, we show that the quantum fluctuations, controlled by h, split the multiphase degeneracy giving rise to an infinite sequence of layering transitions.

  11. A Novel Woodpile Three-Dimensional Terahertz Photonic Crystal

    Institute of Scientific and Technical Information of China (English)

    LIU Huan; YAO Jian-Quan; ZHENG Fang-Hua; XU De-Gang; WANG Peng

    2007-01-01

    A novel woodpile lattice structure is proposed. Based on plane wave expansion (PWE) method, the complete photonic band gaps (PBGs) of the novel woodpile three-dimensional (3D) terahertz (THz) photonic crystal (PC) with a decreasing symmetry relative to a face-centred-tetragonal (fct) symmetry are optimized by varying some structural parameters and the highest band gap ratio can reach 27.61%. Compared to the traditional woodpile lattice, the novel woodpile lattice has a wider range of the Riling ratios to gain high quality PBGs, which provides greater convenience for the manufacturing process. The novel woodpile 3D PC will be very promising for materials of THz functional components.

  12. Three-dimensional wake potential in a streaming dusty plasma

    Indian Academy of Sciences (India)

    M Salahuddin; M K Islam; A K Banerjee; M Salimullah; S K Ghosh

    2003-09-01

    The oscillatory wake potential for a slowly moving or static test dust particulate in a finite temperature, collisionless and unmagnetized dusty plasma with a continuous flow of ions and dust particles has been studied. The collective resonant interaction of the moving test particle with the low-frequency and low-phase-velocity dust-acoustic mode is the origin of the periodic attractive force between the like polarity particulates along and perpendicular to the streaming ions and dust grains resulting into dust-Coulomb crystal formation. This wake potential can explain the three-dimensional dust-Coulomb crystal formation in the laboratory conditions.

  13. Ising Model Coupled to Three-Dimensional Quantum Gravity

    CERN Document Server

    Baillie, C F

    1992-01-01

    We have performed Monte Carlo simulations of the Ising model coupled to three-dimensional quantum gravity based on a summation over dynamical triangulations. These were done both in the microcanonical ensemble, with the number of points in the triangulation and the number of Ising spins fixed, and in the grand canoncal ensemble. We have investigated the two possible cases of the spins living on the vertices of the triangulation (``diect'' case) and the spins living in the middle of the tetrahedra (``dual'' case). We observed phase transitions which are probably second order, and found that the dual implementation more effectively couples the spins to the quantum gravity.

  14. On three-dimensional trace anomaly from holographic local RG

    CERN Document Server

    Kikuchi, Ken; Suzuki, Akihiro

    2016-01-01

    Odd-dimensional quantum field theories (QFTs) can have nonzero trace anomalies if external fields are introduced and some ingredients needed to make Lorentz scalars with appropriate mass dimensions (or weights) are supplied. We have studied a three-dimensional QFT and explicitly computed the trace of the stress tensor using the holographic local renormalization group (RG). We have checked some properties of vector beta functions and the Wess-Zumino consistency condition, however, found the anomalies vanish on fixed points. We clarify what is responsible for the vanishing trace anomalies.

  15. Seismic waves in a three-dimensional block medium

    CERN Document Server

    Aleksandrova, Nadezhda

    2016-01-01

    We study numerically the propagation of seismic waves in a three-dimensional block medium. The medium is modeled by a spatial lattice of masses connected by elastic springs and viscous dampers. We study Lamb's problem under a surface point vertical load. The cases of both step and pulse load are considered. The displacements and velocities are calculated for surface masses. The influence of the viscosity of the dampers on the attenuation of perturbations is studied. We compare our numerical results for the block medium with known analytical solutions for the elastic medium.

  16. Electrified magnetic catalysis in three-dimensional topological insulators

    Science.gov (United States)

    Gorbar, E. V.; Miransky, V. A.; Shovkovy, I. A.; Sukhachov, P. O.

    2016-09-01

    The gap equations for the surface quasiparticle propagators in a slab of three-dimensional topological insulator in external electric and magnetic fields perpendicular to the slab surfaces are analyzed and solved. A different type of magnetic catalysis is revealed with the dynamical generation of both Haldane and Dirac gaps. Its characteristic feature manifests itself in the crucial role that the electric field plays in dynamical symmetry breaking and the generation of a Dirac gap in the slab. It is argued that, for a sufficiently large external electric field, the ground state of the system is a phase with a homogeneous surface charge density.

  17. Three-dimensional imaging of direct-written photonic structures

    CERN Document Server

    Marshall, Graham D; Thayil, Anisha; Withford, Michael J; Booth, Martin

    2010-01-01

    Third harmonic generation microscopy has been used to analyze the morphology of photonic structures created using the femtosecond laser direct-write technique. Three dimensional waveguide arrays and waveguide-Bragg gratings written in fused-silica and doped phosphate glass were investigated. A sensorless adaptive optical system was used to correct the optical aberrations occurring in the sample and microscope system, which had a lateral resolution of less than 500 nm. This non-destructive testing method creates volume reconstructions of photonic devices and reveals details invisible to other linear microscopy and index profilometry techniques.

  18. Three-dimensional array foci of generalized Fibonacci photon sieves

    CERN Document Server

    Zhang, Junyong; Zhu, Jianqiang; Lin, Zunqi

    2015-01-01

    We present a new kind of photon sieves on the basis of the generalized Fibonacci sequences. The required numbers and locations of axial foci can be designed by generalized Fibonacci photon sieves (GFiPS). Furthermore, the three-dimensional array foci can be controllable and adjustable by the optical path difference scaling factor (OPDSF) when the amplitude modulation is replaced with the phase modulation. Multi-focal technologies can be applied to nano-imaging, THZ, laser communications, direct laser writing, optical tweezers or atom trapping, etc.

  19. Canonical and symplectic analysis for three dimensional gravity without dynamics

    CERN Document Server

    Escalante, Alberto

    2016-01-01

    In this paper a detailed Hamiltonian analysis of three-dimensional gravity without dynamics proposed by V. Hussain is performed. We report the complete structure of the constraints and the Dirac brackets are explicitly computed. In addition, the Faddeev-Jackiw symplectic approach is developed; we report the complete set of Faddeev-Jackiw constraints and the generalized brackets, then we show that the Dirac and the generalized Faddeev-Jackiw brackets coincide to each other. Finally, the similarities and advantages between Faddeev-Jackiw and Dirac's formalism are briefly discussed.

  20. Role of retardation in three-dimensional relativistic equations

    Energy Technology Data Exchange (ETDEWEB)

    Lahiff, A.D.; Afnan, I.R. [Department of Physics, The Flinders University of South Australia, GPO Box 2100, Adelaide 5001 (Australia)

    1997-11-01

    Equal-time Green{close_quote}s function is used to derive a three-dimensional integral equation from the Bethe-Salpeter equation. The resultant equation, in the absence of antiparticles, is identical to the use of time-ordered diagrams, and has been used within the framework of {phi}{sup 2}{sigma} coupling to study the role of energy dependence and nonlocality when the two-body potential is the sum of {sigma} exchange and crossed {sigma} exchange. The results show that nonlocality and energy dependence make a substantial contribution to both the on-shell and off-shell amplitudes. {copyright} {ital 1997} {ital The American Physical Society}

  1. Role of retardation in three-dimensional relativistic equations

    Science.gov (United States)

    Lahiff, A. D.; Afnan, I. R.

    1997-11-01

    Equal-time Green's function is used to derive a three-dimensional integral equation from the Bethe-Salpeter equation. The resultant equation, in the absence of antiparticles, is identical to the use of time-ordered diagrams, and has been used within the framework of φ2σ coupling to study the role of energy dependence and nonlocality when the two-body potential is the sum of σ exchange and crossed σ exchange. The results show that nonlocality and energy dependence make a substantial contribution to both the on-shell and off-shell amplitudes.

  2. Three-Dimensional Model for Strip Hot Rolling

    Institute of Scientific and Technical Information of China (English)

    ZHANG Guo-min; XIAO Hong; WANG Chun-hua

    2006-01-01

    A three-dimensional model for strip hot rolling was developed, in which the plastic deformation of strip, the thermal crown of rolls, roll deflection and flattening were calculated by rigid-plastic finite element method, finite difference method, influential function method and elastic finite element method respectively. The roll wear was taken into consideration. The model can provide detailed information such as rolling pressure distribution, contact pressure distribution between backup rolls and work rolls, deflection and flattening of work rolls, lateral distribution of strip thickness, and lateral distribution of front and back tensions. The finish rolling on a 1 450 mm hot strip mill was simulated.

  3. Three-dimensional dilatonic gravity's rainbow: Exact solutions

    Science.gov (United States)

    Hossein Hendi, Seyed; Eslam Panah, Behzad; Panahiyan, Shahram

    2016-10-01

    Deep relations of dark energy scenario and string theory results into dilaton gravity, on the one hand, and the connection between quantum gravity and gravity's rainbow, on the other hand, motivate us to consider three-dimensional dilatonic black hole solutions in gravity's rainbow. We obtain two classes of the solutions, which are polynomial and logarithmic forms. We also calculate conserved and thermodynamic quantities, and examine the first law of thermodynamics for both classes. In addition, we study thermal stability and show that one of the classes is thermally stable while the other one is unstable.

  4. Discrete canonical analysis of three dimensional gravity with cosmological constant

    CERN Document Server

    Berra-Montiel, J

    2014-01-01

    We discuss the interplay between standard canonical analysis and canonical discretization in three-dimensional gravity with cosmological constant. By using the Hamiltonian analysis, we find that the continuum local symmetries of the theory are given by the on-shell space-time diffeomorphisms, which at the action level, corresponds to the Kalb-Ramond transformations. At the time of discretization, although this symmetry is explicitly broken, we prove that the theory still preserves certain gauge freedom generated by a constant curvature relation in terms of holonomies and the Gauss's law in the lattice approach.

  5. Three-dimensional structure of brain tissue at submicrometer resolution

    Science.gov (United States)

    Saiga, Rino; Mizutani, Ryuta; Inomoto, Chie; Takekoshi, Susumu; Nakamura, Naoya; Tsuboi, Akio; Osawa, Motoki; Arai, Makoto; Oshima, Kenichi; Itokawa, Masanari; Uesugi, Kentaro; Takeuchi, Akihisa; Terada, Yasuko; Suzuki, Yoshio

    2016-01-01

    Biological objects are composed of submicrometer structures such as cells and organelles that are essential for their functions. Here, we report on three-dimensional X-ray visualization of cells and organelles at resolutions up to 100 nm by imaging microtomography (micro-CT) equipped with Fresnel zone plate optics. Human cerebral tissue, fruit fly cephalic ganglia, and Escherichia coli bacteria labeled with high atomic-number elements were embedded in epoxy resin and subjected to X-ray microtomography at the BL37XU and BL47XU beamlines of the SPring-8 synchrotron radiation facility. The obtained results indicated that soft tissue structures can be visualized with the imaging microtomography.

  6. Three-dimensional measurement of a tightly focused laser beam

    Directory of Open Access Journals (Sweden)

    Xiangsheng Xie

    2013-02-01

    Full Text Available The spatial structure of a tightly focused light field is measured with a double knife-edge scanning method. The measurement method is based on the use of a high-quality double knife-edge fabricated from a right-angled silicon fragment mounted on a photodetector. The reconstruction of the three-dimensional structures of tightly focused spots is carried out with both uniform and partially obstructed linearly polarized incident light beams. The optical field distribution is found to deviate substantially from the input beam profile in the tightly focused region, which is in good agreement with the results of numerical simulations.

  7. Synthesis of three-dimensional hierarchical cobalt hydroxide microstructures

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    β-Co(OH)2 with three-dimensional (3-D) structures was prepared by a simple hydrothermal method. It was found that the amount of cetyltrimethylammonium bromide (CTAB), the pH value, and the reaction time all had an important influence on the formation of this morphology. The products were characterized by X-ray diffraction, energy-dispersive X-ray analysis, and scanning electron microscopy. A possible mechanism of the formation of the 3-D microstructures of β-Co(OH)2 was proposed.

  8. Three-dimensional point spread function measurements of imaging spectrometers

    Science.gov (United States)

    Jemec, Jurij; Pernuš, Franjo; Likar, Boštjan; Bürmen, Miran

    2017-09-01

    Measuring the three-dimensional point spread function (3D PSF) of imaging spectrometers is a challenging task since it requires a small, monochromatic and bright source. Here we introduce a powerful and practical new approach for 3D PSF measurement on the basis of a bright virtual monochromatic point-like source, which is formed by a collimated light beam and a convex spherical mirror. The effectiveness of the proposed methodology is demonstrated and discussed through 3D PSF measurements of an acousto-optic tunable filter based imaging spectrometer.

  9. Overlap distribution of the three-dimensional Ising model.

    Science.gov (United States)

    Berg, Bernd A; Billoire, Alain; Janke, Wolfhard

    2002-10-01

    We study the Parisi overlap probability density P(L)(q) for the three-dimensional Ising ferromagnet by means of Monte Carlo (MC) simulations. At the critical point, P(L)(q) is peaked around q=0 in contrast with the double peaked magnetic probability density. We give particular attention to the tails of the overlap distribution at the critical point, which we control over up to 500 orders of magnitude by using the multioverlap MC algorithm. Below the critical temperature, interface tension estimates from the overlap probability density are given and their approach to the infinite volume limit appears to be smoother than for estimates from the magnetization.

  10. Modified Three-Dimensional Multicarrier Optical Prime Codes

    Directory of Open Access Journals (Sweden)

    Rajesh Yadav

    2016-01-01

    Full Text Available We propose a mathematical model for novel three-dimensional multicarrier optical codes in terms of wavelength/time/space based on the prime sequence algorithm. The proposed model has been extensively simulated on MATLAB for prime numbers (P to analyze the performance of code in terms of autocorrelation and cross-correlation. The simulated outcome resembles the mathematical model and gives better results over other methods available in the literature as far as autocorrelation and cross-correlation are concerned. The proposed 3D optical codes are more efficient in terms of cardinality, improved security, and providing quality of services.

  11. Observation of three dimensional optical rogue waves through obstacles

    Energy Technology Data Exchange (ETDEWEB)

    Leonetti, Marco, E-mail: marco.leonetti@roma1.infn.it [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Viale Regina Elena, 291 00161 Roma (RM) (Italy); Conti, Claudio [ISC-CNR and Department of Physics, University Sapienza, P.le Aldo Moro 5, I-00185 Roma (Italy)

    2015-06-22

    We observe three-dimensional rogue waves in the speckle distribution of a spatially modulated optical beam. Light is transmitted beyond a partially reflecting obstacle generating optical rogue waves at a controlled position in the shadow of the barrier. When the barrier transmits only 0.07% of the input laser power, we observe the mostly localized event. These results demonstrate that an optimum amount of spatial non-homogeneity maximizes the probability of a gigantic event while the technique we exploit enables to control light behind a fully reflective wall.

  12. Three-dimensional edge extraction in optical scanning holography

    Science.gov (United States)

    Zong, Yonghong; Zhou, Changhe; Ma, Jianyong; Jia, Wei; Wang, Jin

    2016-10-01

    Edge extraction has found applications in various image processing fields, such as in pattern recognition. In this paper, a new method is proposed for edge extraction of three-dimensional objects in optical scanning holography (OSH). Isotropic and anisotropic edge extraction of 3D objects is simulated using spiral phase plates in OSH operating in an incoherent mode. We propose to use a delta function and a spiral phase plate as the pupil functions to realize isotropic and anisotropic edge extraction. Our computer simulations show the capability of extracting the edges of a given 3D object by spiral phase filtering in OSH.

  13. Proton beam writing of three-dimensional microcavities

    Energy Technology Data Exchange (ETDEWEB)

    Vanga, S.K., E-mail: sudheer@nus.edu.sg [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542 (Singapore); Bettiol, A.A. [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542 (Singapore)

    2013-07-01

    Optical micro cavities exhibit high quality factors due to the circulation of resonant optical fields within the cavity. Polymers are good materials for the fabrication of micro cavities for practical applications due to the availability of various refractive indices and their low cost. Polymer micro cavities generally yield low Q-factors compared to semiconductor materials because of inherent material absorption losses, and their Q-factors are limited by the low index contrast between the polymer and the substrate material. In the present work, three dimensional micro cavities were fabricated in SU-8 using proton beam writing to enhance the index contrast by isolating the cavities from the substrate.

  14. Analysis and visualization of complex unsteady three-dimensional flows

    Science.gov (United States)

    Van Dalsem, William R.; Buning, Pieter G.; Dougherty, F. Carroll; Smith, Merritt H.

    1989-01-01

    Flow field animation is the natural choice as a tool in the analysis of the numerical simulations of complex unsteady three-dimensional flows. The PLOT4D extension of the widely used PLOT3D code to allow the interactive animation of a broad range of flow variables was developed and is presented. To allow direct comparison with unsteady experimental smoke and dye flow visualization, the code STREAKER was developed to produce time accurate streaklines. Considerations regarding the development of PLOT4D and STREAKER, and example results are presented.

  15. Seismic waves in a three-dimensional block medium

    Science.gov (United States)

    Aleksandrova, N. I.

    2016-08-01

    We study numerically the propagation of seismic waves in a three-dimensional block medium. The medium is modelled by a spatial lattice of masses connected by elastic springs and viscous dampers. We study Lamb's problem under a surface point vertical load. The cases of both step and pulse load are considered. The displacements and velocities are calculated for surface masses. The influence of the viscosity of the dampers on the attenuation of perturbations is studied. We compare our numerical results for the block medium with known analytical solutions for the elastic medium.

  16. Three-Dimensional Orientation Mapping in the Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Liu, Haihua; Schmidt, Søren; Poulsen, Henning Friis

    2011-01-01

    Over the past decade, efforts have been made to develop nondestructive techniques for three-dimensional (3D) grain-orientation mapping in crystalline materials. 3D x-ray diffraction microscopy and differential-aperture x-ray microscopy can now be used to generate 3D orientation maps with a spatial...... resolution of 200 nanometers (nm). We describe here a nondestructive technique that enables 3D orientation mapping in the transmission electron microscope of mono- and multiphase nanocrystalline materials with a spatial resolution reaching 1 nm. We demonstrate the technique by an experimental study...... of a nanocrystalline aluminum sample and use simulations to validate the principles involved...

  17. Three-dimensional multifunctional optical coherence tomography for skin imaging

    Science.gov (United States)

    Li, En; Makita, Shuichi; Hong, Young-Joo; Kasaragod, Deepa; Sasaoka, Tomoko; Yamanari, Masahiro; Sugiyama, Satoshi; Yasuno, Yoshiaki

    2016-02-01

    Optical coherence tomography (OCT) visualizes cross-sectional microstructures of biological tissues. Recent developments of multifunctional OCT (MF-OCT) provides multiple optical contrasts which can reveal currently unknown tissue properties. In this contribution we demonstrate multifunctional OCT specially designed for dermatological investigation. And by utilizing it to measure four different body parts of in vivo human skin, three-dimensional scattering OCT, OCT angiography, polarization uniformity tomography, and local birefringence tomography images were obtained by a single scan. They respectively contrast the structure and morphology, vasculature, melanin content and collagen traits of the tissue.

  18. High-resolution three-dimensional imaging of dislocations.

    Science.gov (United States)

    Barnard, J S; Sharp, J; Tong, J R; Midgley, P A

    2006-07-21

    Dislocations and their interactions govern the properties of many materials, ranging from work hardening in metals to device pathology in semiconductor laser diodes. However, conventional electron micrographs are simply two-dimensional projections of three-dimensional (3D) structures, and even stereo microscopy cannot reveal the true 3D complexity of defect structures. Here, we describe an electron tomographic method that yields 3D reconstructions of dislocation networks with a spatial resolution three orders of magnitude better than previous work. We illustrate the method's success with a study of dislocations in a GaN epilayer, where dislocation densities of 1010 per square centimeter are common.

  19. Optimal control of three-dimensional steamflooding processes

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei; Fred Ramirez, W. (Dept. of Chemical Engineering, Univ. of Colorado, Boulder, CO (United States))

    1994-06-01

    A system science approach using optimal control theory of distributed parameter systems has been developed to determine operating strategies that maximize the economic profitability of the steamflooding processes. Necessary conditions of optimization are established by using the discrete form of calculus of variations and Pontryagin's Maximum Principle. The performance of this approach is investigated through two actual three-dimensional steamflooding projects. The optimization results show this method yields significant improvements over the original operating strategies. These improvements cannot be achieved through traditional design methods

  20. Ordinary polarization singularities in three-dimensional optical fields.

    Science.gov (United States)

    Freund, Isaac

    2012-06-15

    In generic three-dimensional optical fields the canonical point polarization singularities are points of circular polarization, C points on C lines, and points of linear polarization, L points on L lines. These special points are surrounded by a sea of ordinary points. In planes oriented normal to the principle axes of the polarization ellipse at the point, every ordinary point is also a singularity, here an ordinary polarization singularity, or O point. Interactions between O points, between O points and C points, and between O points and L points are described that highlight the fact that a consistent description of optical fields containing C and L lines must include O points.

  1. Three Dimensional Transformations in the Film Subtitle Translation

    Institute of Scientific and Technical Information of China (English)

    陈志海

    2015-01-01

    Film plays an indispensable part in cultural exchange. However, current scholars’studies on the film subtitle transla⁃tion are less than literary translation. There exists no systematic strategy and theory guiding it, and there still exists some problems. This paper introduces eco-translatology to film subtitle translation. Eco-translatology proposes that translation is an alternative cy⁃cle of translators’adaptation and selection activities in translational eco-environment. The translation method focuses on three-dimensional transformation, namely linguistic, cultural and communicative dimensions.

  2. Three dimensional evolution of differentially rotating magnetized neutron stars

    CERN Document Server

    Kiuchi, Kenta; Shibata, Masaru

    2012-01-01

    We construct a new three-dimensional general relativistic magnetohydrodynamics code, in which a fixed mesh refinement technique is implemented. To ensure the divergence-free condition as well as the magnetic flux conservation, we employ the method by Balsara (2001). Using this new code, we evolve differentially rotating magnetized neutron stars, and find that a magnetically driven outflow is launched from the star exhibiting a kink instability. The matter ejection rate and Poynting flux are still consistent with our previous finding (Shibata et al., 2011) obtained in axisymmetric simulations.

  3. Three dimensional monocular SLAM for autonomous drone navigation

    OpenAIRE

    Dehem, Boris

    2017-01-01

    This master's thesis expands on work previously done at the UCL's autonomous drone project to allow three dimensional simultaneous localization and mapping by a low-cost quadcopter. In GPS-denied environments, drones have to rely on their on-board sensors to localize themselves. We decided to use the drone's front camera to build a map of the environment and to localize the drone within that map. We take a keyframe-based approach, building a map from a small set of snapshots of the drone's ca...

  4. Three-dimensional global fluid simulations of cylindrical magnetized plasmas

    DEFF Research Database (Denmark)

    Naulin, Volker; Windisch, T.; Grulke, O.

    2008-01-01

    . Thus, it is possible to assess the reproductive and predictive capabilities of plasma simulations in unprecedented detail. Here, three-dimensional global fluid simulations of a cylindrical magnetized plasma are presented. This plasma is characterized by the existence of spatially localized sources...... and sinks. The traditional scale separation paradigm is not applied in the simulation model to account for the important evolution of the background profiles due to the dynamics of turbulent fluctuations. Furthermore, the fluid modeling of sheath boundary conditions, which determine the plasma conditions...

  5. Three-Dimensional Magnetohydrodynamic Simulation of Slapper Initiation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, J S; Hrousis, C A

    2010-03-09

    Although useful information can be gleaned from 2D and even 1D simulations of slapper type initiation systems, these systems are inherently three-dimensional and therefore require full 3D representation to model all relevant details. Further, such representation provides additional insight into optimizing the design of such devices from a first-principles perspective and can thereby reduce experimental costs. We discuss in this paper several ongoing efforts in modeling these systems, our pursuit of validation, and extension of these methods to other systems. Our results show the substantial dependence upon highly accurate global equations of state and resistivity models in these analyses.

  6. Three-dimensional dilatonic gravity's rainbow: Exact solutions

    Science.gov (United States)

    Hossein Hendi, Seyed; Eslam Panah, Behzad; Panahiyan, Shahram

    2016-10-01

    Deep relations of dark energy scenario and string theory results into dilaton gravity, on the one hand, and the connection between quantum gravity and gravity's rainbow, on the other hand, motivate us to consider three-dimensional dilatonic black hole solutions in gravity's rainbow. We obtain two classes of the solutions, which are polynomial and logarithmic forms. We also calculate conserved and thermodynamic quantities, and examine the first law of thermodynamics for both classes. In addition, we study thermal stability and show that one of the classes is thermally stable while the other one is unstable.

  7. Multiple scattering of light in three-dimensional photonic quasicrystals.

    Science.gov (United States)

    Ledermann, Alexandra; Wiersma, Diederik S; Wegener, Martin; von Freymann, Georg

    2009-02-01

    Recent experiments on three-dimensional icosahedral dielectric photonic quasicrystals have shown several unexpected features: transmitted femtosecond pulses developed a trailing "diffusive" exponential tail and the sum of (zeroth-order) transmittance and reflectance was well below unity. These experimental findings have previously been ascribed to sample imperfections. Here, we analyze these findings by using 3D periodic approximants of the ideal photonic quasicrystals. We show that the experimental observations can be explained in terms of multiple scattering of light within these structures, i.e., in terms of intrinsic rather than purely extrinsic quasicrystal properties.

  8. Three-dimensional nanojunction device models for photovoltaics

    Science.gov (United States)

    Wangperawong, Artit; Bent, Stacey F.

    2011-06-01

    A model is developed to describe the behavior of three-dimensionally nanostructured photovoltaic devices, distinguishing between isolated radial pn junctions and interdigitated pn junctions. We examine two specific interdigitated architectures, the point-contact nanojunction and the extended nanojunction, which are most relevant to experimental devices reported to date but have yet to be distinguished in the field. The model is also applied to polycrystalline CdTe devices with inverted grain boundaries. We demonstrate that for CdTe/CdS solar cells using low-quality materials, the efficiency of the extended nanojunction geometry is superior to other designs considered.

  9. The application of three-dimensional photoelasticity to impact problems

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, I.C. [Moscow State Univ. of Civil Engeneering (Russian Federation); Fedorov, A.V. [Mining School of Nantes (France)

    1995-12-31

    A method is proposed for the solution of three-dimensional dynamic problems in geometrically complex structural configurations under impact. The methodology developed employs the generation of photoelastically observable stress wave propagation in a birefringent material applied to the external surfaces of a structure. This work demonstrated the extension of this technique to impact loading. Problems of practical engineering application, such as the gluing of birefringent material to test models were examined experimentally. Pulsed magnetic fields generated by capacitor discharge were employed on typical complex engineering models to demonstrate that the methodology is adequate for solving practical impact problems.

  10. On three-dimensional trace anomaly from holographic local RG

    Science.gov (United States)

    Kikuchi, Ken; Hosoda, Hiroto; Suzuki, Akihiro

    2017-01-01

    Odd-dimensional quantum field theories (QFTs) can have nonzero trace anomalies if external fields are introduced and some ingredients needed to make Lorentz scalars with appropriate mass dimensions (or weights) are supplied. We have studied a three-dimensional QFT and explicitly computed the trace of the stress tensor using the holographic local renormalization group (RG). We have checked some properties of vector beta functions and the Wess-Zumino consistency condition; however, we have found that the anomalies vanish on fixed points. We clarify what is responsible for the vanishing trace anomalies.

  11. Three-Dimensional Bone Adaptation of the Proximal Femur

    DEFF Research Database (Denmark)

    Bagge, Mette

    1998-01-01

    The bone remodeling of a three-dimensional model of the proximal femur is considered. The bone adaptation is numerically described as an evolution in time formulated such that the structural change goes in an optimal direction within each time step for the optimal boundary conditions. In the bone...... remodeling scheme is included the memory of past loadings to account for the delay in the bone response to the load changes. In order to get a realistic bone adaptation process, the bone structure at the onset of the remodeling needs to be realistic too. A start design is obtained by structural optimization...

  12. Black holes in three-dimensional dilaton gravity theories

    CERN Document Server

    Sá, P M; Lemos, J P S; Sa, Paulo M; Kleber, Antares; Lemos, Jose P S

    1995-01-01

    Three dimensional black holes in a generalized dilaton gravity action theory are analysed. The theory is specified by two fields, the dilaton and the graviton, and two parameters, the cosmological constant and the Brans-Dicke parameter. It contains seven different cases, of which one distinguishes as special cases, string theory, general relativity and a theory equivalent to four dimensional general relativity with one Killing vector. We study the causal structure and geodesic motion of null and timelike particles in the black hole geometries and find the ADM masses of the different solutions.

  13. Three Dimensional Digital Image Processing using Edge Detectors

    Directory of Open Access Journals (Sweden)

    John Schmeelk

    2005-11-01

    Full Text Available This paper provides an introduction to three dimensional image edge detection and its relationship to partial derivatives, convolutions and wavelets. We are especially addressing the notion of edge detection because it has far reaching applications in all areas of research to include medical research. A patient can be diagnosed as having an aneurysm by studying an angiogram. An angiogram is the visual view of the blood vessels whereby the edges are highlighted through the implementation of edge detectors. This process is completed through convolution, wavelets and matrix techniques. Some illustrations included will be vertical, horizontal, Sobel and wavelet edge detectors.

  14. AN EXAMPLE OF THREE-DIMENSIONAL PROGRESSIVE SLOPE FAILURE

    Institute of Scientific and Technical Information of China (English)

    王家臣; 骆中洲

    1995-01-01

    In fact, the failure of any slope takes place progressively, but the progressive failure mechanism has not been emphasized sufficently in the present stability analysis of slopes. This paper provides an example of the progressive slope failure which took place at Pingzhuang west surface coal mine and was numbered the 26th slide. The three-dimensional reliability model for progressive slope failure is used to study the failure process of the 26th slide. The outcomes indicate that the progressive failure is indeed the failure mechanism of the slide.

  15. Frozen Gaussian approximation for three-dimensional seismic wave propagation

    Science.gov (United States)

    Chai, Lihui; Tong, Ping; Yang, Xu

    2016-09-01

    We present a systematic introduction on applying frozen Gaussian approximation (FGA) to compute synthetic seismograms in three-dimensional earth models. In this method, seismic wavefield is decomposed into frozen (fixed-width) Gaussian functions, which propagate along ray paths. Rather than the coherent state solution to the wave equation, this method is rigorously derived by asymptotic expansion on phase plane, with analysis of its accuracy determined by the ratio of short wavelength over large domain size. Similar to other ray-based beam methods (e.g. Gaussian beam methods), one can use relatively small number of Gaussians to get accurate approximations of high-frequency wavefield. The algorithm is embarrassingly parallel, which can drastically speed up the computation with a multicore-processor computer station. We illustrate the accuracy and efficiency of the method by comparing it to the spectral element method for a three-dimensional (3D) seismic wave propagation in homogeneous media, where one has the analytical solution as a benchmark. As another proof of methodology, simulations of high-frequency seismic wave propagation in heterogeneous media are performed for 3D waveguide model and smoothed Marmousi model respectively. The second contribution of this paper is that, we incorporate the Snell's law into the FGA formulation, and asymptotically derive reflection, transmission and free surface conditions for FGA to compute high-frequency seismic wave propagation in high contrast media. We numerically test these conditions by computing traveltime kernels of different phases in the 3D crust-over-mantle model.

  16. Three-dimensional bioprinting in tissue engineering and regenerative medicine.

    Science.gov (United States)

    Gao, Guifang; Cui, Xiaofeng

    2016-02-01

    With the advances of stem cell research, development of intelligent biomaterials and three-dimensional biofabrication strategies, highly mimicked tissue or organs can be engineered. Among all the biofabrication approaches, bioprinting based on inkjet printing technology has the promises to deliver and create biomimicked tissue with high throughput, digital control, and the capacity of single cell manipulation. Therefore, this enabling technology has great potential in regenerative medicine and translational applications. The most current advances in organ and tissue bioprinting based on the thermal inkjet printing technology are described in this review, including vasculature, muscle, cartilage, and bone. In addition, the benign side effect of bioprinting to the printed mammalian cells can be utilized for gene or drug delivery, which can be achieved conveniently during precise cell placement for tissue construction. With layer-by-layer assembly, three-dimensional tissues with complex structures can be printed using converted medical images. Therefore, bioprinting based on thermal inkjet is so far the most optimal solution to engineer vascular system to the thick and complex tissues. Collectively, bioprinting has great potential and broad applications in tissue engineering and regenerative medicine. The future advances of bioprinting include the integration of different printing mechanisms to engineer biphasic or triphasic tissues with optimized scaffolds and further understanding of stem cell biology.

  17. Modular transportation system with a three dimensional routeing

    Directory of Open Access Journals (Sweden)

    Löffler Christoph

    2015-12-01

    Full Text Available In intra-enterprise logistics and automation of manufacturing processes general a rising productivity by high flexibility is required. Existing transportation systems exclusively use two-dimensional track sections, because they can be served with standard drives. Because of these simple structures the transport speed is limited and thereby also the throughput. In this paper now a modular transportation system is presented which could reach higher speeds with a direct drive and the use of centrifugal force compensating curves. Simultaneously the system also can change the altitude. All this succeeds with the integration of three-dimensional track sections. Therefore a two piped guiding system with a long stator linear motor was designed. To combine the linear motor with the three dimensional track special stator elements were developed which allow a bending of the stator to follow the route course. The current work deals with the implementation of a mechanical passive switch, which is operated by the electromagnetic forces of the linear motor. So no additional mechanical actors or a separate electromagnetic system are necessary.

  18. Vocal Fold Pathologies and Three-Dimensional Flow Separation Phenomena

    Science.gov (United States)

    Apostoli, Adam G.; Weiland, Kelley S.; Plesniak, Michael W.

    2013-11-01

    Polyps and nodules are two different pathologies, which are geometric abnormalities that form on the medial surface of the vocal folds, and have been shown to significantly disrupt a person's ability to communicate. Although the mechanism by which the vocal folds self-oscillate and the three-dimensional nature of the glottal jet has been studied, the effect of irregularities caused by pathologies is not fully understood. Examining the formation and evolution of vortical structures created by a geometric protuberance is important, not only for understanding the aerodynamic forces exerted by these structures on the vocal folds, but also in the treatment of the above-mentioned pathological conditions. Using a wall-mounted prolate hemispheroid with a 2:1 aspect ratio in cross flow, the present investigation considers three-dimensional flow separation induced by a model vocal fold polyp. Building on previous work using skin friction line visualization, both the velocity flow field and wall pressure measurements around the model polyp are presented and compared. Supported by the National Science Foundation, Grant No. CBET-1236351 and GW Center for Biomimetics and Bioinspired Engineering (COBRE).

  19. Three-dimensional flows in a transonic compressor rotor

    Science.gov (United States)

    Reid, Lonnie; Celestina, Mark L.; Dewitt, Kenneth; Keith, Theo

    1991-01-01

    This study involves an experimental and numerical investigation of the three-dimensional flows in a transonic compressor rotor. A variety of data which could be used, in a complementary fashion, to validate/calibrate the computational fluid dynamics turbomachinery code and improve understanding of the flow physics, were acquired. Detailed radial survey data which consisted of total pressure, total temperature, static pressure and flow angle were obtained at stations upstream and downstream of the rotor blade. Detailed velocity and turbulence profiles were obtained upstream of the rotor and used as the upstream boundary conditions for the numerical analysis. Calibrated flush-mounted hot film probes were used to measure wall shear stress on the hub and casing walls upstream of the rotor. The blade-to-blade shear-stress angle distributions were obtained at two axial locations on the rotor casing, using flush-mounted hot film probes. A numerical analysis conducted using a three-dimensional Navier-Stokes code was compared with the experimental results.

  20. Three-dimensional saltating processes of multiple sediment particles

    Institute of Scientific and Technical Information of China (English)

    Hsiao-Wen WANG; Hong-Yuan LEE; Po-Ning LEE

    2009-01-01

    The purpose of this study was to investigate the interacting mechanism between the saltating particles near a channel bed.A three-dimensional real-time flow visualization technique was developed to measure the interparticle collision behaviors during the saltating process.Based on the experimental data,the distribution of the collision points was found to be symmetric.This confirms the assumption that the projections of the collision points onto the reasonable plane are uniformly distributed.A three-dimensional saltating model was also developed.This model produced satisfactory results.The model is able to simulate the continuous saltating trajectories of several particles.The simulated dimensionless saltating height,longitudinal and vertical saltation velocity components were found to increase as the dimensionless particle diameter and the dimensionless flow transport capacity parameter increase,while the simulated lateral saltation velocity component varies inversely with the dimensionless flow transport capacity parameter.A regression equation for the bed load transport rate was also obtained.

  1. Three-dimensional Majorana fermions in chiral superconductors.

    Science.gov (United States)

    Kozii, Vladyslav; Venderbos, Jörn W F; Fu, Liang

    2016-12-01

    Using a systematic symmetry and topology analysis, we establish that three-dimensional chiral superconductors with strong spin-orbit coupling and odd-parity pairing generically host low-energy nodal quasiparticles that are spin-nondegenerate and realize Majorana fermions in three dimensions. By examining all types of chiral Cooper pairs with total angular momentum J formed by Bloch electrons with angular momentum j in crystals, we obtain a comprehensive classification of gapless Majorana quasiparticles in terms of energy-momentum relation and location on the Fermi surface. We show that the existence of bulk Majorana fermions in the vicinity of spin-selective point nodes is rooted in the nonunitary nature of chiral pairing in spin-orbit-coupled superconductors. We address experimental signatures of Majorana fermions and find that the nuclear magnetic resonance spin relaxation rate is significantly suppressed for nuclear spins polarized along the nodal direction as a consequence of the spin-selective Majorana nature of nodal quasiparticles. Furthermore, Majorana nodes in the bulk have nontrivial topology and imply the presence of Majorana bound states on the surface, which form arcs in momentum space. We conclude by proposing the heavy fermion superconductor PrOs4Sb12 and related materials as promising candidates for nonunitary chiral superconductors hosting three-dimensional Majorana fermions.

  2. Three-dimensional vision sensors for autonomous robots

    Science.gov (United States)

    Uchiyama, Takashi; Okabayashi, Keizyu; Wakitani, Jun

    1993-09-01

    A three dimensional measurement system, which is important for developing autonomous robots is described. Industrial robots used in today's plants are of the preprogrammed teaching playback type. It is necessary to develop autonomous robots which can work based on sensor information for intelligent manufacturing systems. Moreover, practical use of robots which work in unstructured environments such as outdoors and in space is expected. To realize this, a function to measure objects and the environment three-dimensionally is a key technology. Additional important requirements for robotic sensors are real-time processing and compactness. We have developed smart 3-D vision sensors for the purpose of realizing autonomous robots. These are two kinds of sensors with different functions corresponding to the application. One is a slitted light range finder ( SLRF ) to measure stationary objects. The other is a real-time tracking vision ( RTTV ) which can measure moving objects at high speed. SLRF uses multiple slitted lights which are generated by a semiconductor laser through an interference filter and a cylindrical lens. Furthermore, we developed a liquid crystal shutter with multiple electrodes. We devised a technique to make coded slitted light by putting this shutter in front of the light source. As a result, using the principle of triangulation, objects can be measured in three dimensions. In addition, high-speed image input was enabled by projecting multiple slitted light at the same time. We have confirmed the effectiveness of the SLRF applied to a hand-eye system using a robot.

  3. Three-Dimensional Dynamical Instabilities in Galactic Ionization Fronts

    Science.gov (United States)

    Whalen, Daniel J.; Norman, Michael L.

    2008-01-01

    Ionization front instabilities have long been of interest for their suspected role in a variety of phenomena in the Galaxy, from the formation of bright rims and "elephant trunks" in nebulae to triggered star formation in molecular clouds. Numerical treatments of these instabilities have historically been limited in both dimensionality and input physics, leaving important questions about their true evolution unanswered. We present the first three-dimensional radiation hydrodynamical calculations of both R-type (rarefied) and D-type (dense) ionization front instabilities in Galactic environments (i.e., solar-metallicity gas). Consistent with linear stability analyses of planar D-type fronts, our models exhibit many short-wavelength perturbations that grow at early times and later evolve into fewer large-wavelength structures. The simulations demonstrate that both self-consistent radiative transfer and three-dimensional flow introduce significant morphological differences to unstable modes when compared to earlier two-dimensional approximate models. We find that the amplitude of the instabilities in the nonlinear regime is primarily determined by the efficiency of cooling within the shocked neutral shell. Strong radiative cooling leads to long, extended structures with pronounced clumping, while weaker cooling leads to saturated modes that devolve into turbulent flows. These results suggest that expanding H II regions may either promote or provide turbulent support against the formation of later generations of stars, with potential consequences for star formation rates in the Galaxy today.

  4. Three dimensional visualisation of human facial exposure to solar ultraviolet.

    Science.gov (United States)

    Downs, Nathan; Parisi, Alfio

    2007-01-01

    A three dimensional computer model of the human face has been developed to represent solar ultraviolet exposures recorded by dosimeter measurements on a manikin headform under low cloud conditions and various solar zenith angles. Additionally, polysulfone dosimeters have been successfully miniaturised to provide the detailed measurements required across the face. The headform used in this research was scanned at 709 individual locations to make a wireframe mesh consisting of 18 vertical contours and 49 horizontal contours covering half the manikin's frontal facial topography. Additionally, the back of the headform and neck have also been scanned at 576 locations. Each scanned location has been used as a viable dosimeter position on the headform and represents a grid intersection point on the developed computer wireframe. A series of exposures recorded by dosimeters have been translated into three dimensional exposure ratio maps, representing ambient solar ultraviolet exposure. High dosimeter density has allowed for the development of individual topographic contour models which take into account complex variation in the face and improve upon previously employed techniques which utilise fewer dosimeters to interpolate exposure across facial contours. Exposure ratios for solar zenith angle ranges of 0 degrees -30 degrees, 30 degrees -50 degrees, and 50 degrees -80 degrees have been developed.

  5. Nanoscale three-dimensional imaging of the human myocyte.

    Science.gov (United States)

    Sulkin, Matthew S; Yang, Fei; Holzem, Katherine M; Van Leer, Brandon; Bugge, Cliff; Laughner, Jacob I; Green, Karen; Efimov, Igor R

    2014-10-01

    The ventricular human myocyte is spatially organized for optimal ATP and Ca(2+) delivery to sarcomeric myosin and ionic pumps during every excitation-contraction cycle. Comprehension of three-dimensional geometry of the tightly packed ultrastructure has been derived from discontinuous two-dimensional images, but has never been precisely reconstructed or analyzed in human myocardium. Using a focused ion beam scanning electron microscope, we created nanoscale resolution serial images to quantify the three-dimensional ultrastructure of a human left ventricular myocyte. Transverse tubules (t-tubule), lipid droplets, A-bands, and mitochondria occupy 1.8, 1.9, 10.8, and 27.9% of the myocyte volume, respectively. The complex t-tubule system has a small tortuosity (1.04±0.01), and is composed of long transverse segments with diameters of 317±24nm and short branches. Our data indicates that lipid droplets located well beneath the sarcolemma are proximal to t-tubules, where 59% (13 of 22) of lipid droplet centroids are within 0.50μm of a t-tubule. This spatial association could have an important implication in the development and treatment of heart failure because it connects two independently known pathophysiological alterations, a substrate switch from fatty acids to glucose and t-tubular derangement.

  6. Three-dimensional percolation modeling of self-healing composites.

    Science.gov (United States)

    Dementsov, Alexander; Privman, Vladimir

    2008-08-01

    We study the self-healing process of materials with embedded "glue"-carrying cells, in the regime of the onset of the initial fatigue. Three-dimensional numerical simulations within the percolation-model approach are reported. The main numerical challenge taken up in the present work has been to extend the calculation of the conductance to three-dimensional lattices. Our results confirm the general features of the process: The onset of material fatigue is delayed, by development of a plateaulike time dependence of the material quality. We demonstrate that, in this low-damage regime, the changes in the conductance and thus in similar transport and response properties of the material can be used as measures of the material quality degradation. A new feature found for three dimensions, where it is much more profound than in earlier-studied two-dimensional systems, is the competition between the healing cells. Even for low initial densities of the healing cells, they interfere with each other and reduce each other's effective healing efficiency.

  7. Three-dimensional shock wave diffraction off a discontinuous edge

    Science.gov (United States)

    Cooppan, S.; Skews, B.

    2017-03-01

    The interaction of three-dimensional vortex flows was investigated through vortex shedding off a discontinuous edge. Two wedges of 14.5° wedge angle (up and downstream edges) were separated by an offset. The size of the offset (5, 10, and 20 mm) and the Mach number (Mach 1.32, 1.42, and 1.6) were the key parameters investigated. Experimental images were taken and computational simulations were run; a close relation was found between the two. This enabled the three-dimensional effects of the flow to be studied and analysed. It was found, as the offset increased in size, the vortices shed off the up and downstream edges took a longer time to merge and the strength of the interaction was weaker. The vortex topology changed with a larger offset; the downstream vortex was thinner (in terms of cross-sectional diameter) adjacent to the offset, which is an indication of a change in density, than the rest of the vortex along the downstream diffraction edge. This particular feature was more prevalent at lower Mach numbers. The effect of a higher Mach number was to increase the rate of dissipation of the vortices, lengthen the shear layer due to the higher upstream velocity, and make the vortex profile elliptical.

  8. Direct-writing organic three-dimensional nanofibrous structure

    Science.gov (United States)

    Wang, Han; Zheng, Gaofeng; Li, Wenwang; Wang, Xiang; Sun, Daoheng

    2011-02-01

    Direct-writing technology based on Near-Field Electrospinning (NFES) was used to fabricate an organic three-dimensional nanofibrous circle on the patterned silicon substrate. In NFES, straight jet without splitting and chaotic motion was utilized to direct-write orderly nanofiber. When the collector movement speed was lower than electrospinning rate, the relaxed nanofiber would be lead into the pendulum motion by the electrical field force and Coulomb repulsion force from the residual charges on the collector. When the relative air humidity is lower than 35%, individual nanofiber with larger elastic resistance would reveal a good self-assembly performance. Owing to the guidance of the electric field force at the edge of the micro-pattern, a nanofiber was deposited layer by layer to format a 3D nanofibrous circle on the top surface of the micro-pattern. The dimension scale of 3D nanofibrous circle was smaller than 30 µm. With the help of a microscope, a 3D nanofibrous circle can be deposited precisely on the strip micro-pattern with width of 4 µm. Furthermore, a 3D nanofibrous circle in different shapes can be obtained by using special micro-patterns. This organic three-dimensional nanofibrous circle has created a new aspect for the fabrication of organic micro/nanosystems.

  9. Three-Dimensional Turbulent Reconnection Induced by the Plasmoid Instability

    Science.gov (United States)

    Bhattacharjee, A.; Huang, Y. M.

    2014-12-01

    It has been established that the Sweet-Parker current layer in high-Lundquist-number reconnection is unstable to the super-Alfvenic plasmoid instability. Past two-dimensional magnetohydrodynamic simulations have demonstrated that the plasmoid instability leads to a new regime in which the Sweet-Parker current layer evolves into a chain of plasmoids connected by secondary current sheets and the averaged reconnection rate becomes nearly independent of the Lundquist number. In a three-dimensional configuration with a guide field, the additional degree of freedom allows plasmoid instabilities to grow at oblique angles [S. Baalrud et al. Phys. Plasmas 19, 022101 (2012)] and develop the complex dynamics of flux ropes which overlap, cause field-line stochasticization, and self-generate a turbulent state. Three-dimensional simulations in the high-Lundquist-number regime show the formation of cigar-shaped eddies elongated in the direction of the local magnetic field, which is a signature of anisotropic MHD turbulence. Furthermore, the energy fluctuation spectra are found to satisfy power laws in the inertial range. The averaged 3D reconnection rate in the self-generated turbulent state is of the order of a hundredth of the characteristic Alfven speed, which is an order of magnitude lower than the reconnection rate reported in recent studies of externally driven 3D turbulent reconnection. The physical reasons for these differences will be discussed.

  10. Tailoring thermal conductivity via three-dimensional porous alumina

    Science.gov (United States)

    Abad, Begoña; Maiz, Jon; Ruiz-Clavijo, Alejandra; Caballero-Calero, Olga; Martin-Gonzalez, Marisol

    2016-12-01

    Three-dimensional anodic alumina templates (3D-AAO) are an astonishing framework with open highly ordered three-dimensional skeleton structures. Since these templates are architecturally different from conventional solids or porous templates, they teem with opportunities for engineering thermal properties. By establishing the mechanisms of heat transfer in these frameworks, we aim to create materials with tailored thermal properties. The effective thermal conductivity of an empty 3D-AAO membrane was measured. As the effective medium theory was not valid to extract the skeletal thermal conductivity of 3D-AAO, a simple 3D thermal conduction model was developed, based on a mixed series and parallel thermal resistor circuit, giving a skeletal thermal conductivity value of approximately 1.25 W·m-1·K-1, which matches the value of the ordinary AAO membranes prepared from the same acid solution. The effect of different filler materials as well as the variation of the number of transversal nanochannels and the length of the 3D-AAO membrane in the effective thermal conductivity of the composite was studied. Finally, the thermal conductivity of two 3D-AAO membranes filled with cobalt and bismuth telluride was also measured, which was in good agreement with the thermal model predictions. Therefore, this work proved this structure as a powerful approach to tailor thermal properties.

  11. Three-dimensional finite element analysis of platform switched implant

    Science.gov (United States)

    2017-01-01

    PURPOSE The purpose of this study was to analyze the influence of the platform switching concept on an implant system and peri-implant bone using three-dimensional finite element analysis. MATERIALS AND METHODS Two three-dimensional finite element models for wide platform and platform switching were created. In the wide platform model, a wide platform abutment was connected to a wide platform implant. In the platform switching model, the wide platform abutment of the wide platform model was replaced by a regular platform abutment. A contact condition was set between the implant components. A vertical load of 300 N was applied to the crown. The maximum von Mises stress values and displacements of the two models were compared to analyze the biomechanical behavior of the models. RESULTS In the two models, the stress was mainly concentrated at the bottom of the abutment and the top surface of the implant in both models. However, the von Mises stress values were much higher in the platform switching model in most of the components, except for the bone. The highest von Mises values and stress distribution pattern of the bone were similar in the two models. The components of the platform switching model showed greater displacement than those of the wide platform model. CONCLUSION Due to the stress concentration generated in the implant and the prosthodontic components of the platform switched implant, the mechanical complications might occur when platform switching concept is used. PMID:28243389

  12. Automated photogrammetry for three-dimensional models of urban spaces

    Science.gov (United States)

    Leberl, Franz; Meixner, Philipp; Wendel, Andreas; Irschara, Arnold

    2012-02-01

    The location-aware Internet is inspiring intensive work addressing the automated assembly of three-dimensional models of urban spaces with their buildings, circulation spaces, vegetation, signs, even their above-ground and underground utility lines. Two-dimensional geographic information systems (GISs) and municipal utility information exist and can serve to guide the creation of models being built with aerial, sometimes satellite imagery, streetside images, indoor imaging, and alternatively with light detection and ranging systems (LiDARs) carried on airplanes, cars, or mounted on tripods. We review the results of current research to automate the information extraction from sensor data. We show that aerial photography at ground sampling distances (GSD) of 1 to 10 cm is well suited to provide geometry data about building facades and roofs, that streetside imagery at 0.5 to 2 cm is particularly interesting when it is collected within community photo collections (CPCs) by the general public, and that the transition to digital imaging has opened the no-cost option of highly overlapping images in support of a more complete and thus more economical automation. LiDAR-systems are a widely used source of three-dimensional data, but they deliver information not really superior to digital photography.

  13. A Three-Dimensional Map of Milky-Way Dust

    CERN Document Server

    Green, Gregory M; Finkbeiner, Douglas P; Rix, Hans-Walter; Martin, Nicolas; Burgett, William; Draper, Peter W; Flewelling, Heather; Hodapp, Klaus; Kaiser, Nicholas; Kudritzki, Rolf Peter; Magnier, Eugene; Metcalfe, Nigel; Price, Paul; Tonry, John; Wainscoat, Richard

    2015-01-01

    We present a three-dimensional map of interstellar dust reddening, covering three-quarters of the sky out to a distance of several kiloparsecs, based on Pan-STARRS 1 and 2MASS photometry. The map reveals a wealth of detailed structure, from filaments to large cloud complexes. The map has a hybrid angular resolution, with most of the map at an angular resolution of 3.4' to 13.7', and a maximum distance resolution of ~25%. The three-dimensional distribution of dust is determined in a fully probabilistic framework, yielding the uncertainty in the reddening distribution along each line of sight, as well as stellar distances, reddenings and classifications for 800 million stars detected by Pan-STARRS 1. We demonstrate the consistency of our reddening estimates with those of two-dimensional emission-based maps of dust reddening. In particular, we find agreement with the Planck 353 GHz optical depth-based reddening map to within 0.05 mag in E(B-V) to a depth of 0.5 mag, and explore systematics at reddenings less tha...

  14. Three-dimensional protonic conductivity in porous organic cage solids

    Science.gov (United States)

    Liu, Ming; Chen, Linjiang; Lewis, Scott; Chong, Samantha Y.; Little, Marc A.; Hasell, Tom; Aldous, Iain M.; Brown, Craig M.; Smith, Martin W.; Morrison, Carole A.; Hardwick, Laurence J.; Cooper, Andrew I.

    2016-09-01

    Proton conduction is a fundamental process in biology and in devices such as proton exchange membrane fuel cells. To maximize proton conduction, three-dimensional conduction pathways are preferred over one-dimensional pathways, which prevent conduction in two dimensions. Many crystalline porous solids to date show one-dimensional proton conduction. Here we report porous molecular cages with proton conductivities (up to 10-3 S cm-1 at high relative humidity) that compete with extended metal-organic frameworks. The structure of the organic cage imposes a conduction pathway that is necessarily three-dimensional. The cage molecules also promote proton transfer by confining the water molecules while being sufficiently flexible to allow hydrogen bond reorganization. The proton conduction is explained at the molecular level through a combination of proton conductivity measurements, crystallography, molecular simulations and quasi-elastic neutron scattering. These results provide a starting point for high-temperature, anhydrous proton conductors through inclusion of guests other than water in the cage pores.

  15. Three-dimensional recurring patterns in excitable media

    Energy Technology Data Exchange (ETDEWEB)

    Biton, Y. [Physics Department, Ben-Gurion University of the Negev, Beer-Sheva 84105 (Israel); Rabinovitch, A., E-mail: avinoam@bgu.ac.il [Physics Department, Ben-Gurion University of the Negev, Beer-Sheva 84105 (Israel); Braunstein, D. [Physics Department, Sami Shamoon College of Engineering, Beer-Sheva (Israel); Friedman, M. [Department of Information Systems Engineering, Ben-Gurion University, Beer-Sheva 84105 (Israel); Aviram, I. [Physics Department, Ben-Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2011-06-13

    A new method to create three-dimensional periodic patterns in excitable media is presented. The method is demonstrated and the patterns are obtained with the help of two types of 3D 'spiral pairs' generators, which are respectively based on a 'corner effect' and a 'unidirectional propagation' processes. The results portray time-repeating patterns resembling fruits or potteries. The method is easy to implement and can be used to form other types of 3D patterns in excitable media. The question of periodicity of the patterns thus obtained is resolved by calculating the singular lines (filaments) around which they evolve and showing their unique reattachment property. Actual realizations could be conceived e.g. in chemical reactions such as Belousov-Zhabotinsky. Possible severe cardiac arrhythmias following the appearance of such patterns in the action potential of the heart are considered. -- Highlights: → New method to create three-dimensional periodic patterns in excitable media. → Singular lines (filaments) for the corner effect are presented. → Filaments are shown to exhibit periodic behavior.

  16. Three-dimensional solidification and melting using magnetic field control

    Science.gov (United States)

    Dulikravich, George S.; Ahuja, Vineet

    1993-01-01

    A new two-fluid mathematical model for fully three dimensional steady solidification under the influence of an arbitrary acceleration vector and with or without an arbitrary externally applied steady magnetic field have been formulated and integrated numerically. The model includes Joule heating and allows for separate temperature dependent physical properties within the melt and the solid. Latent heat of phase change during melting/solidification was incorporated using an enthalpy method. Mushy region was automatically captured by varying viscosity orders of magnitude between liquidus and solidus temperature. Computational results were obtained for silicon melt solidification in a parallelepiped container cooled from above and from a side. The results confirm that the magnetic field has a profound influence on the solidifying melt flow field thus changing convective heat transfer through the boundaries and the amount and shape of the solid accrued. This suggests that development of a quick-response algorithm for active control of three dimensional solidification is feasible since it would require low strength magnetic fields.

  17. Tailoring thermal conductivity via three-dimensional porous alumina.

    Science.gov (United States)

    Abad, Begoña; Maiz, Jon; Ruiz-Clavijo, Alejandra; Caballero-Calero, Olga; Martin-Gonzalez, Marisol

    2016-12-09

    Three-dimensional anodic alumina templates (3D-AAO) are an astonishing framework with open highly ordered three-dimensional skeleton structures. Since these templates are architecturally different from conventional solids or porous templates, they teem with opportunities for engineering thermal properties. By establishing the mechanisms of heat transfer in these frameworks, we aim to create materials with tailored thermal properties. The effective thermal conductivity of an empty 3D-AAO membrane was measured. As the effective medium theory was not valid to extract the skeletal thermal conductivity of 3D-AAO, a simple 3D thermal conduction model was developed, based on a mixed series and parallel thermal resistor circuit, giving a skeletal thermal conductivity value of approximately 1.25 W·m(-1)·K(-1), which matches the value of the ordinary AAO membranes prepared from the same acid solution. The effect of different filler materials as well as the variation of the number of transversal nanochannels and the length of the 3D-AAO membrane in the effective thermal conductivity of the composite was studied. Finally, the thermal conductivity of two 3D-AAO membranes filled with cobalt and bismuth telluride was also measured, which was in good agreement with the thermal model predictions. Therefore, this work proved this structure as a powerful approach to tailor thermal properties.

  18. Three-Dimensional Concentration Measurements around Actively Tracking Blue Crabs

    Science.gov (United States)

    Dickman, B. D.; Jackson, J. L.; Weissburg, M. J.; Webster, D. R.

    2006-11-01

    Many aquatic arthropods locate food, suitable habitats, and mates solely through information extracted by chemical signals in their environment. Chemical plumes detected by larger animals are influenced by turbulence that creates an intermittent and unpredictable chemical stimulus environment. To link the stimulus pattern to behavior, we have developed a measurement system to quantify the instantaneous odor concentration surrounding a freely tracking blue crab through three-dimensional laser-induced fluorescence (3DLIF). A blue crab receives chemical stimulus at several locations, including the antennules near the mouth region and the distal tips of the legs and claws. Hence, three-dimensional measurements of the concentration field are required to link behavior to plume structure. During trials, crabs began their search 150 cm downstream of a source, and walking kinematics were recording simultaneously. The crabs were reversibly ``blindfolded'' during tracking to prevent aversive reactions to the intense laser light. Our experiments allow us to examine how hypothesized navigational cues, such as concentration bursts at the antennules and spatial asymmetry in concentration at the distributed chemosensory organs on the legs and claws, results in particular decisions during navigation.

  19. A biorthogonality relationship for three-dimensional couple stress problem

    Institute of Scientific and Technical Information of China (English)

    LUO JianHui; LI QiuSheng; LIU GuangDong

    2009-01-01

    The duality solution for elasticity and the biorthogonality relationship have been well researched. Now the couple stress theory becomes a new research spot but there is few research for the biorthogonality relationship for couple stress theory comparing to classical elasticity. A new state vector is presented for three dimensional couple stress problems of prismatic structures. A new biorthogonality relation-ship of couple stress is discovered. The dual partial differential equations of couple stress problem are derived by the new state vector. By two important identical equations the new biorthogonality rela-tionship is proved based on the method of separation of variables. The symplectic orthogonality rela-tionship to three dimensional couple stress theory may be decomposed into two independently and symmetrically orthogonality relationships. The new biorthogonality relationship includes the symplectic orthogonality relationship. The biorthogonality relationship of couple stress may also be degenerated into the theory of elasticity. The new state vector and biorthogonality relationship provide theoretic foundation for the research on the schemes of separation of variables and eigenfunction expansion of couple stress theory.

  20. Three-dimensional angular domain optical projection tomography

    Science.gov (United States)

    Ng, Eldon; Vasefi, Fartash; Roumeliotis, Michael; Kaminska, Bozena; Carson, Jeffrey J. L.

    2011-03-01

    Angular Domain Imaging (ADI) has been previously demonstrated to generate projection images of attenuating targets embedded within a turbid medium. The imaging system employs a silicon micro-tunnel array positioned between the sample and the detection system to reject scattered photons that have deviated from the initial propagation direction and to select for ballistic and quasi-ballistic photons that have retained their forward trajectory. Two dimensional tomographic images can be reconstructed from ADI projections collected at a multitude of angles. The objective of this work was to extend the system to three dimensions by collecting several tomographic images and stacking the reconstructed slices to generate a three dimensional volume representative of the imaging target. A diode laser (808nm, CW) with a beam expander was used to illuminate the sample cuvette. An Angular Filter Array (AFA) of 80 μm × 80 μm square-shaped tunnels 2 cm in length was used to select for image forming quasi-ballistic photons. Images were detected with a linear CCD. Our approach was to use a SCARA robot to rotate and translate the sample to collect sufficient projections to reconstruct a three dimensional volume. A custom designed 3D target consisting of 4 truncated cones was imaged and reconstructed with filtered backprojection and iterative methods. A 0.5 mm graphite rod was used to collect the forward model, while a truncated pseudoinverse was used to approximate the backward model for the iterative algorithm.