WorldWideScience

Sample records for echocardiography doppler color

  1. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  2. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  3. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  4. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  5. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  6. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  7. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  8. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  9. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  10. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  11. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  12. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  13. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  14. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  15. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  16. Digital storage and analysis of color Doppler echocardiograms

    Science.gov (United States)

    Chandra, S.; Thomas, J. D.

    1997-01-01

    Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

  17. Preload dependence of color M-mode Doppler flow propagation velocity in controls and in patients with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Søndergaard, E

    2000-01-01

    The purpose of this study was to assess the effects of preload alterations on color M-mode flow propagation velocity (Vp) in volunteers with normal left ventricular (LV) function and in patients with depressed LV function. Color M-mode Doppler echocardiography was performed during Valsalva maneuv...

  18. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  19. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  20. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  1. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  2. Evaluation of regional wall motion abnormalities of the heart. Comparison with Doppler tissue echocardiography, MR-tagging and levocardiography

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Hamm, B.; Borges, A.C.; Walde, T.; Rutsch, W.; Baumann, G.

    2004-01-01

    Purpose: To compare the visual analysis of magnetic resonance imaging (MRI) with the tagging technique and Doppler tissue echocardiography with invasive ventriculography in detecting and quantifying regional left ventricular wall motion abnormalities. Materials and Methods: Sixteen patients with coronary artery disease and a history of prior myocardial infarction underwent invasive ventriculography. Doppler tissue echocardiography and MR-tagging within one week. Regional wall motion abnormalities (WMA) were detected in all patients. WMA were graded as normal=1; hypokinetic=2; akinetic=3; or dyskinetic=4. For agreement between MRI, echocardiography, and ventriculography the kappa coefficient (κ) according to Cohen was calculated. Results: The kappa coefficient (κ) was 0.962 for agreement between MRI and echocardiography and 0.602 for agreement between MRI and ventriculography as well as between echocardiography and ventriculography. Conclusion: Reliable analysis of regional left ventricular wall motion abnormalities is feasible using visual analysis of MR-tagging. MRI and Doppler tissue echocardiography detect more WMA than invasive ventriculography and grade them as more severe. (orig.)

  3. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  4. Contrast echocardiography: history, micro bubble characteristics and instrumental techniques

    International Nuclear Information System (INIS)

    Cubides, Carlos; Restrepo, Gustavo; Aristizabal, Dagnovar; Munera, Ana

    2006-01-01

    This article describes the history of contrast echocardiography, the physical characteristics of the contrast agent's micro bubbles, the main instrumental tools (mechanical index, focus and focusing, frame rate), and the echocardiography techniques (second harmonic imaging, fusion harmonic, power pulse inversion imaging, triggered imaging, intermittent harmonic power Doppler, color power angio and acoustic densitometry), actually available for clinical use

  5. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  6. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  7. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  8. The history of echocardiography.

    Science.gov (United States)

    Edler, Inge; Lindström, Kjell

    2004-12-01

    review ends with a mention of color Doppler echocardiography. (E-mail:

  9. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  10. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  11. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2009-12-15

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  12. Color Doppler Ultrasonographic Findings of Vascular Leiomyoma: Pathologic Correlation

    International Nuclear Information System (INIS)

    Ko, Ji Young; Koh, Sung Hye; Min, Soo Kee; Choi, A Lam; Jang, Kyung Mi; Lee, Yul; Lee, Kwan Seop; Lee, Hyun; Sohn, Jeong Hee; Kim, Sam Soo

    2009-01-01

    To evaluate the distribution of color flow signals on color Doppler ultrasonography of vascular leiomyomas and to correlate them with pathologic findings. We retrospectively analyzed color Doppler ultrasonographic images and pathologic slides of six vascular leiomyomas. We classified the patterns of distribution of color flow signals into localized compact cluster types and non-cluster types, and the pathologic findings into three subtypes: solid, venous and cavernous. All cases showed well-defined homogenous hypoechoic subcutaneous masses on gray-scale ultrasonography. Three cases showed localized compact cluster types on color Doppler ultrasonography, one in each subtype (solid, venous and cavernous). For the three non-cluster types, again there was on in each subtype. In addition, on pathologic analysis the zone of the localized compact cluster of color flow signals coincided with a cluster of larger, vascular caliber masses. Localized compact clusters of color flow signals on color Doppler ultrasonography were seen in 50% of our cases and correlated with a cluster of larger vascular caliber in the mass. But the pattern of distribution of color flows didn't show a correlation with pathologic type

  13. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  14. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  15. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  16. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  17. Acute intrascrotal pathology in childhood: color Doppler study

    International Nuclear Information System (INIS)

    Cinta Sanguesa, C.; Muro, D.; Cortina, H.; Moreno, A.

    1997-01-01

    To asses the utility of color Doppler ultrasound in the study of acute intrascrotal pathology in childhood. Seventy-five boys with evidence of an acute intrascrotal abnormality were studied by means of color Doppler ultrasound. A 7.5 MHz linear transducer was used. The most common findings was inflammatory disease (60%) which was indicated by the presence of hyperemia in color Doppler. Of the nine boys with testicular torsion (12%) two presented extravaginal torsion, with a complete absence of intratesticular vascularization. Intravaginal torsion was observed in seven patients, six of whom presented reduced vascularization in the abnormal testicle with respect to the healthy testicle. There was one false negative in which testicular vascularization was normal but 360 degree centigree torsion was found at surgery. In addition, there were seven cases of hydatid torsion (9.33%), four of idiopathic scrotal swelling (5.3%). two cases of intermittent torsion (2.6%) and one case of Shcolein-Henoch purpura (1.3%). The ultrasound findings were completely nornal in seven boys. Color Doppler is a rapid, noninvasive method for assessing testicular blood flow. The elevated sensitivity and specificity (85.7 and 100%, respectively, in our series) for testicular torsion make Doppler ultrasound a highly reliable method for the study of this disorder. (Author) 18 refs

  18. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  19. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    International Nuclear Information System (INIS)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan; Hwang, Hee Yong

    1995-01-01

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  20. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  1. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  2. Magnetic angioresonance of the carotid artery: correlation with color Doppler ultrasound

    International Nuclear Information System (INIS)

    Cotilla, J.; Miralles, M.; Cairols, M.C.; Dolz, J.L.; Vilanova, J.C.; Capdevila, A.

    1998-01-01

    To determine the value of magnetic angioresonance (MAR) in grading carotid stenosis, comparing it with color Doppler and intraarterial digital subtraction angiography (IADSA). A comparative study using color Doppler and MAR was carried out in 84 patients with coratid lesions. Fifty-two of the patients underwent angiographic study as well. The comparison of MAR versus arteriography in discriminating stenosis of more than 70%, expressed in terms of sensitivity specificity, overall precision and the kappa concordance index, gave values of 87.2, 90.8, 89.4 and 0.78%, respectively. When MAR was compared with color Doppler, the results were 86.8, 85.9, 86.3 and 0.72%, respectively. The results of the comparison between color Doppler and arteriography were 82.2, 86.2, 84.6 and 0.68%, respectively. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability. The better correlation of MAR, as compares with angiography and color Doppler, with the grade of carotid stenosis indicates the high degree of reliability of this imaging technique. (Author) 29 refs

  3. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  4. Ekhokardiografi Endokardiosis Penyakit Katup Mitral Jantung Anjing (ECHOCARDIOGRAPHY OF ENDOCARDIOSIS MITRAL VALVE HEART DISEASE IN DOGS

    Directory of Open Access Journals (Sweden)

    Deni Noviana

    2013-08-01

    Full Text Available Endocardiosis is a disease commonly found in Pomeranian dog characterized by progressive myxomatousdegeneration of the atrio-ventricular valves especially in the mitral valve. The purpose of this study was todefine the diagnose and severeity of this disease on the Pomeranian by using brightness mode, motion mode,dan color flow Doppler echocardiography technique. Echocardiography was performed on 8 Pomeranianconsisting of 6 males and 2 females with age range of 2-14 years. Brightness mode echocardiography wasused to see the echotexture of endocardium, mitral valve, and the valve movement. The results showedendocardium thickening, along with chronic fibrosis and nodular thickening of the anterior and posteriormitral valve leaflet. Three out of seven cases showed prolapsed of the mitral valve. Motion modeechocardiography was performed in order to measure left ventricle internal dimension, myocardium thickness,fractional shortening, left atrial and aortic dimension. The results showed myocardium thickening, alongwith left atrial enlargement. Color flow Doppler echocardiography was used to confirm the mitral valveregurgitation. Three of seven cases showed the presence of regurgitation signed by turbulence color of theprolapsed mitral valve. Based on the degree of severity, scoring system used in this study, endocardiosis canbe divided into three types that are mild, moderate and severe.

  5. Color doppler ultrasound diagonosis in cesarean scar pregnancy

    International Nuclear Information System (INIS)

    Chen Shanshan; Xia Fei; Shen Zongji; Xu Jianyin; Gu Xinxian

    2010-01-01

    Objective: To study the sonographic characteristics of cesarean scar pregnancy(CSP), and the value of color Doppler in the diagnosis of CSP. Methods: Twelve cases of CSP were all confirmed by transabdominal and transvaginal ultrasound. Results: The ultrasonogram of CSP could be divided into gestational sac type and mixed mass type. Conclusion: Color Doppler can give guidance to the early diagnosis, treatment and following-up of CSP because of the sonographic specifity of CSP. (authors)

  6. [Pilot study of echocardiographic studies using color- and pulsed-wave spectral Doppler methods in blue-crowned amazons (Amazona ventralis) and blue-fronted amazons (Amazona a. aestiva)].

    Science.gov (United States)

    Pees, M; Straub, J; Schumacher, J; Gompf, R; Krautwald-Junghanns, M E

    2005-02-01

    Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.

  7. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  8. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  9. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  10. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  11. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  12. Vesico-ureteral reflux: diagnosis and staging with voiding color doppler US Preliminary experience

    International Nuclear Information System (INIS)

    Farina, Renato; Arena, Carmela; Pennisi, Francesco; Di Benedetto, Vincenzo; Politi, Guido; Di Benedetto, Aurelio

    2000-01-01

    Introduction: The aim of this study is to assess the accuracy of a new US examination: 'voiding color Doppler US ' in the early diagnosis and staging of vesico-ureteral reflux (VUR). The contrast agent US was SH U 508A (Levovist, Schering, Berlin), which produces a chromatic accentuation of the signals picked up by the color Doppler US. Eighteen patients (10 females, eight males) were recruited for the study. In two patients a second examination was performed for follow-up after a VUR conservative therapy. All patients were taken under examination for the evaluation of possible VUR. In all patients the voiding color Doppler US was followed by voiding cystourethrography (VCUG) and the data obtained were compared. Materials and methods: A total of 18 patients aged between 3 months and 10 years, were recruited for the study. The results of the examination were the following: urinary tract infections, follow-up of VUR after conservative or surgical therapy, miscellaneous indications. Voiding color Doppler US was performed, followed by a VCUG. The voiding color Doppler US consists in the trans-catheter introduction of a contrast agent SHU 508 A (Levovist, Schering, Ag. Berlin) into the bladder and a subsequent test with the color Doppler US to show or exclude the presence of reflux into the ureters and/or into the pyelo-caliceal cavity of the kidneys. After the introduction of the contrast agent US the ultrasound scanning of the bladder, the ureters and the pyelo-caliceal cavity was performed to examine the reflux degree. The ultrasonographic investigations were perfomed with AU 590 asyncronus US (Esaote Biomedica, Genova) with a 3.5 MHz convex probe. Results: After the trans-catheter introduction of the contrast agent US, vesico-ureteral reflux occured in 13 patients (77.2%). The reflux degree was also measured by means of ultrasound and was later confirmed by VCUG. The mean times of each examination were as follows: initial US, 10 min; catheterization, 8 min; voiding

  13. The color Doppler ultrasonography in in the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose A.; Rodriguez Villalonga, Luis; Borras Migues, Marisela; Quinnones Castro, Mayda

    2004-01-01

    The paper was aimed at evaluating the accuracy of color Doppler ultrasonography, a noninvasive method, in the diagnosis of deep vein thrombosis of the lower limbs, comparing it to the results of the cruel and costly diagnostic g olden rule , that is, phlebography. Methods: Color Doppler ultrasonography served to assess 102 patients clinically suspected of deep vein thrombosis of the lower limbs, taking into account the following criteria: vein compressibility, echographic images, color, Vein Doppler signal modulation after several maneuvers and distal compression. Sensitivity, specificity, positive and negative predictive values and diagnostic efficacy were estimated for each criteria, taking the phlebography as a reference. Results: Total or partial lack of vein compressibility combined with the vein flow evaluation is the ultrasonographic criterion that reveals higher degree of sensitivity, specificity and efficacy (0,98; 0,95 and 0,97 respectively. Color Doppler ultrasonography is a highly effective noninvasive diagnostic method that detects deep vein thrombosis in proximal areas of the lower limbs

  14. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  15. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  16. A brief history of fetal echocardiography and its impact on the management of congenital heart disease.

    Science.gov (United States)

    Maulik, Dev; Nanda, Navin C; Maulik, Devika; Vilchez, Gustavo

    2017-12-01

    Congenital heart disease (CHD), the most common congenital malformation, is associated with adverse outcome. Development of fetal echocardiography has made prenatal diagnosis of CHD a reality, and in the process revolutionized its management. This historical review briefly narrates this development over the decades focusing on the emergence of the primary modalities of fetal echocardiography comprised of the time-motion mode, two-dimensional B-mode, spectral Doppler, color Doppler, and three- and four-dimensional cardiac imaging. Collaboration between clinicians and engineers has been central to these advances. Also discussed are the accuracy and impact of fetal echocardiography on the management of CHD, and especially its role in the prenatal diagnosis of critical CHD in individualizing the management and improving the outcome. Despite these advances, most cases of CHD are not identified prenatally, emphasizing the continuing need for further technological and educational innovation and improvement. © 2017, Wiley Periodicals, Inc.

  17. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  18. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  19. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    Directory of Open Access Journals (Sweden)

    Ali A. Hasan

    2013-07-01

    Conclusions: Application of color Doppler examination increases the accuracy of real time chest ultrasound to discriminate pleural thickening from minimal pleural effusion and hence color Doppler examination proved to be a useful diagnostic tool to real-time gray-scale ultrasound for diagnosis of minimal pleural effusion.

  20. Color Doppler Score: A New Approach for Monitoring a Large Placental Chorioangioma

    Directory of Open Access Journals (Sweden)

    Maria Angelica Zoppi

    2014-01-01

    Full Text Available We employed color Doppler score as an innovative approach for the prenatal diagnosis and monitoring of a large placental chorioangioma case diagnosed at 26 weeks and the subjective semiquantitative assessment of the vascularization. The blood flow was assessed by a color Doppler score based on the intensity of the color signal with the following value ranges: (1 no flow, (2 minimal flow, (3 moderate flow, and (4 high vascular flow. Weekly examinations were programmed. Initially, a color Doppler score 3 was assigned, remaining unchanged at the following two exams and decreasing to Score 2 in the following 2 exams and to Score 1 thereafter. The ultrasonographic scan showed an increase of the mass size at the second and third exams and was followed by an arrest of the growth persisting for the rest of the pregnancy. Some hyperechogenic spots inside the mass appeared at the end. Expectant management was opted for, and the delivery was at 39, 2 weeks and maternal and fetal outcomes were favourable. The color Doppler score employed for assessment of vascularization in successive examinations proved to be an important tool for the prediction of the chorioangioma involution, and this new approach of monitoring allowed effective surveillance and successful tailored management.

  1. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  2. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  3. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  4. Alveolar Echinococcosis of the Liver: Correlative Color Doppler US, CT, and MRI Study

    International Nuclear Information System (INIS)

    Cokun, A.; Oeztuerk, M.; Karahan, O.I.; Erdogan, N.; Ikin, S.; Guelec, M.

    2004-01-01

    Purpose: To determine and compare the imaging features of hepatic alveolar Echinococcosis using color Doppler US, CT, and MRI. Material and Methods: Abdominal CT and MRI with and without contrast agents and color Doppler US were performed on seven patients with hepatic alveolar Echinococcosis. The lesions were evaluated for location, features of echogenicity, intensity and density, calcification, and vascular, hilar, and perihepatic involvement. The diagnosis was confirmed histopathologically in all patients. Results: Six patients had solitary lesions, and one displayed multiple lesions. The lesions were generally seen as heterogeneous and hyper- or hypoechoic when imaged with color Doppler US, hypodense with CT, and hypointense with MRI, in comparison with the liver parenchyma. Calcification, central necrosis, and small peripheral cysts were observed in six, seven, and four patients, respectively. Vascular flow or contrast enhancement was not observed in any of the cases. A look at the respective advantages of each method reveals that calcification was best rendered visible via CT, small peripheral cysts with T2-weighted MRI, central necrosis with CT and MRI, and perihepatic invasion with multiplanar MRI. Vascular involvement was revealed by all methods. Conclusion: Color Doppler US, CT, and MR imaging function extremely well as complementary methods in the diagnosis of HAE. Color Doppler US should be performed in these patients owing to its ability to efficiently detect the disease. Knowledge of imaging characteristics makes it possible to radiologically ascertain an early diagnosis

  5. Basic indications for the performance of Color Doppler echocardiography

    International Nuclear Information System (INIS)

    Manzur, Fernando; Olivo, Carlos

    2005-01-01

    Clinical practice based on evidence takes off emphasis in intuition; clinical experience and rational physiopathology give sufficient bases for the clinical decision assessment and emphasizes the evidence's examination for the clinical investigation. The comprehension of certain evidence rules is necessary for the correct interpretation of literature in respect to the causes, diagnostic tools and treatment strategies. The main aim of this research is to make a protocol for the indications of an echocardiogram in the clinical practice and to educate our country's general physicians in this conduct. The good practice is due to initiatives, activities and functional models that are in progress worldwide, as confirmed by evidence. Objective: echocardiography is actually the gold standard for the study of heart anatomy and physiology. Since its introduction in the clinical practice more than three decades ago, it has had such diffusion that it is considered an important tool in the cardiology assistance. It provides trustworthy functional anatomic information, as well as diagnosis and is decisive in the treatment and resolution of cardiovascular diseases. The progressive development of this technique has enabled its use in all the different fields that may affect the cardiovascular system. The objective is to help the clinical physicians in the making of decisions in concrete situations, guaranteeing them that the diagnosis is based on results given by valid scientific studies. In accordance to this, different studies as well as task force and management guides representative of the worldwide literature were compiled

  6. Color doppler findings of gastric varices compared with findings on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Suga, Toshihiro [Sapporo Kosei General Hospital (Japan)

    2002-08-01

    The aim of this study was to evaluate the hemodynamics of gastric varices. We evaluated the detection rates of gastric varices, inflowing vessels to gastric varices, and outflowing vessels from gastric varices in 24 patients with gastric varices, using color Doppler sonography, and compared these findings with computed tomography findings. Eighteen patients had F2-type varices and 6 had F3-type, classified according to the Japanese Research Society for Portal Hypertension. Fourteen patients had fundal varices, and 10 had cardiac and fundal varices. The detection rates of collateral veins using color Doppler sonography were as follows: gastric varices were detected in all 24 patients (100%); inflowing vessels, in 21 of the 24 patients (87.5%); and outflowing vessels, in 18 of the 24 patients (75.0%). The detection rates of collateral veins, using computed tomography, were: gastric varices were detected in all 24 patients (100%); inflowing vessels, in all 24 patients (100%); and outflowing vessles, in 21 of the 24 patients (87.5%). The color Doppler findings agreed perfectly with the computed tomography findings in 13 of the 24 patients (54.2%). Although color Doppler sonography is a useful, noninvasive modality for evaluating the hemodynamics of gastric varices, it falls short in visualizing the detailed hemodynamics of the inflowing and outflowing vessels of gastric varices in half of the patients when compared with computed tomography. (author)

  7. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2011-01-01

    hypertrophy, effusion) and by color Doppler (synovial hyperemia) before and 4 weeks after US-guided steroid injection. Results US detected 121 compartments with active disease (joints, tendon sheaths and 1 ganglion cyst). Multiple compartments were involved in 80% of the ankle regions. The talo-crural joint...

  8. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  9. Cardiovascular assessment of patients with Ullrich-Turner's Syndrome on Doppler echocardiography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Castro Ana Valéria Barros de

    2002-01-01

    Full Text Available OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta. Their ages ranged from 10 to 28 (mean of 16.7 years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%; 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7, mosaics (n=5, and deletions (n=3. No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively. This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

  10. Study of retrobulbar hemodynamics in diabetes via color doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2014-09-01

    Full Text Available AIM: To explore the changes of retrobulbar hemodynamics in diabetes via color doppler ultrasound. METHODS: Totally 80 patients(160 eyeswith eye diseases in type 2 diabetes from June 2010 to May 2013 in our hospital were enrolled as research group. By fundus photography and direct ophthalmoscopy, patients were assigned to diabetes without retinopathy group(DNR subgroup, non-proliferative diabetic retinopathy group(NPDR subgroupand proliferative diabetic retinopathy group(PDR subgroup. Of 60 healthy patients(120 eyesover the same period were chosen as control group. The doppler parameters of central retinal artery(CRA, posterior ciliary artery(PCAand ophthalmic artery(OAwere measured.RESULTS: There were significant differences on circulatory parameters of CRA, PCA and OA between both groups(PPPCONCLUSION: The monitoring of retinal blood flow and analysis of blood spectrum morphology via color doppler ultrasound can effectively evaluate the degree of diabetic retinopathy lesions, especially before DR vascular disease. Early detection can reveal the hemodynamic change pattern of DR, facilitating the prevention of diabetic eye complications and improvement of the quality of life.

  11. Color doppler energy (CDE) : initial ten-months experience

    International Nuclear Information System (INIS)

    Ro, Young Jin; Son, Hyun Ju; Lee, Suck Hong; Kim, Byung Soo; Han, Kook Sang; Nam, SAng Hwa; Lee, Keum Seob; Shin Se Kwon

    1996-01-01

    Color Doppler imaging(CDI) has shortcomings, including random noise, aliasing, and angle dependence. To overcome these, a method using CD US, termed power doppler or Color Doppler Energy(CDE), has recently been introduced. The purpose of this study was to show the clinical usefulness of CDE. We retrospectively analyzed the CDI and CDE of 61 cases(20 renal pseudotumors, 8 musculoskeletal inflammations, 17 epididymitis or epididymo-orchitis, 3 varicoceles, 1 normal testis, 1 hepatocellualr carcinoma, 7 renal cell carcinoma, 1 renal angiomyolipoma, and 3 splenic varices). CDI and CDE scans were obtained at the same region with constant scan plane. The color gain was increased until noise first became perceptible, and scans were always obtained in such a way that the maximum amount of vascularity was shown. Thereafter, the vascularity, vascular displacement, and the vascular relationship between CDI and CDE were compared. In 17 of 20 cases of pseudotumor in the kidney, normal vascularity was identified in CDI and CDE, but was more cleary visible in CDE. In three cases, there was no visible vascularity in CDI, but normal vascularity in CDE. In eight cases of musculoskeletal inflammation and 17 cases of epididymitis with or without orchitis, the vascularity was increased due to hyperemia, which was more prominently seen in CDE than in CDI. In three varicoceles, CDE appeared to be better in demonstrating low velocity flow. In one patient who was suspected of having acute testicular torsion, CDE was helpful in excluding this suspicion. In one case of hepatocellualr carcinoma, seven cases of renal cell carcinoma, one case of renal angiomyolipoma, and three cases of splenic varices, CDE was better than CDI in showing the vascularity, vascular relationship, and vascular displacement

  12. Analysis on correlation between overall classification on color doppler ultrasound and clinical stages of atherosclerosis obliterans

    International Nuclear Information System (INIS)

    Zhang Dongmei; Liu Meihan; Shi Weidong; Chen Enqi; Li Xinying; Lin Yu

    2010-01-01

    Objective: To investigate the correlation and the clinical significance between the overall classification on color Doppler ultrasound and the clinical stages of atherosclerosis obliterans (ASO), and evaluate the extent of arterial lesions comprehensively. Methods: 125 patients of ASO, who were divided into three groups of mild, moderate and severe with Color Doppler ultrasound according to differences of occlusion, quantity, degree of stenosis and collateral number, were analyzed with clinical stages, then their associations were studied with Spearman rank analysis. Results: The clinical manifestations of ASO patients who were divided into three groups of mild, moderate and severe according to overall classification on color Doppler ultrasound were respectively gradually serious, which had positive correlations with the stages of I, II and III according to clinical stages. Spearman rank analysis showed that the correlation coefficients (rs)was 0.797 2 between two groups (P<0.01), there was good consistency between the overall classification on color Doppler ultrasound and the clinical stagesof ASO. Conclusion: The overall classification of ASO on color Doppler ultrasound has considered impact of many other factors on the clinical symptoms,such as the level of the local narrow, narrow scope, segments of occlusion and collateral arteries, which divides the lesions more objectively, shows good consistency with the clinical stages. (authors)

  13. Diagnostic agreement between panoramic radiographs and color doppler images of carotid atheroma

    Directory of Open Access Journals (Sweden)

    Claudia Maria Romano-Sousa

    2009-02-01

    Full Text Available The aim of this study was to investigate the agreement between diagnoses of calcified atheroma seen on panoramic radiographs and color Doppler images. Our interest stems from the fact that panoramic images can show the presence of atheroma regardless of the level of obstruction detected by color Doppler images. Panoramic and color Doppler images of 16 patients obtained from the archives of the Health Department of the city of Valença, RJ, Brazil, were analyzed in this study. Both sides of each patient were observed on the images, with a total of 32 analyzed cervical regions. The level of agreement between diagnoses was analyzed using the Kappa statistics. There was a high level of agreement, with a Kappa value of 0.78. In conclusion, panoramic radiographs can help detecting calcifications in the cervical region of patients susceptible to vascular diseases predisposing to myocardial infarction and cerebrovascular accidents. If properly trained and informed, dentists can refer their patients to a physician for a cardiovascular evaluation in order to receive proper and timely medical treatment.

  14. Power and color Doppler ultrasound settings for inflammatory flow: impact on scoring of disease activity in patients with rheumatoid arthritis.

    Science.gov (United States)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin; Ellegaard, Karen; D'Agostino, Maria Antonietta; Iagnocco, Annamaria; Naredo, Esperanza; Balint, Peter; Wakefield, Richard J; Torp-Pedersen, Arendse; Terslev, Lene

    2015-02-01

    To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. Six different types of ultrasound machines were used. On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. Power Doppler was more sensitive on half of the machines, whereas color Doppler was more sensitive on the other half, using both factory settings and study settings. There was an average increase in Doppler sensitivity, despite modality, of 78% when study settings were applied. Over the 6 machines, 2 Doppler modalities, and 2 settings, the grades for each of 7 of the patients varied between 0 and 3, while the grades for each of the other 4 patients varied between 0 and 2. The effect of using different machines, Doppler modalities, and settings has a considerable influence on the quantification of inflammation by ultrasound in RA patients, and this must be taken into account in multicenter studies. Copyright © 2015 by the American College of Rheumatology.

  15. Studi Penentuan Kecepatan Aliran Darah dan Frekuensi Terimaan Pasien Atherosclerosis Menggunakan USG Color Doppler

    OpenAIRE

    Mulyani, Emba

    2014-01-01

    Jurnal Fisika Medik Studi Penentuan Kecepatan Aliran Darah dan Frekuensi Terimaan Pasien Atherosclerosis Menggunakan USG Color Doppler Mulyani H211 08 507 Pembimbing Utama Sri Dewi Astuty Ilyas,Ssi, Msi Nip.19750513 199903 2 001 Pembimbing Pertama Dahlang Tahir, Msi, Ph.D Nip.19750907 200003 1 001 ABSTRACT Research about Study of determination blood speed of current and freq uency give patient atherosclero sis uses plane USG Color Doppler had be...

  16. Análisis de perforantes de la epigástrica inferior profunda con Angio TC 3D, Eco Doppler color y Doppler simple de ultrasonidos en colgajo DIEP: resultados preliminares Analysis of deep inferior epigastric perforating vessels with 3D CT angiography, color Doppler ultrasonography and Doppler in diep flaps: preliminary results

    Directory of Open Access Journals (Sweden)

    J. Castro García

    2008-09-01

    Full Text Available Nuestro objetivo es la validación de la Angio TC tridimensional como herramienta de planificación de los colgajos DIEP, comparándolo con el Doppler de ultrasonidos (US y eco Doppler color. Entre enero de 2006 y marzo de 2007 se realiza en 11 pacientes (13 DIEP un estudio comparativo prospectivo entre el Doppler de US, eco Doppler color y Angio TC con reconstrucción tridimensional, utilizando como dato de referencia los hallazgos intraoperatorios. En dicho proceso se localiza la mejor perforante que pueda servir como pedículo al colgajo DIEP en función de su localización, calibre, trayecto y relaciones anatómicas con respecto al músculo. La Angio TC con reconstrucción tridimensional, demuestra una especificidad del 100% (IC 95% 75.3-100 lo que le convierte en una prueba con un alto valor predictivo positivo y una excelente herramienta en la planificación de los colgajos de perforantes. El eco Doppler color determinó, que tan sólo en un 46,1% (IC 95% 19,2-74,9 de los pacientes, la perforante seleccionada por la prueba de forma preoperatoria, coincidía con la perforante elegida en quirófano. Con el Doppler de US, en un 30,8 % (IC 95% 9,1-61,4 de los colgajos estudiados, coincidía la mejor perforante escogida de forma preoperatoria, con los hallazgos obtenidos tras la disección del colgajo. En el presente estudio, la Angio TC tridimensional se ha mostrado como una técnica con una gran especificidad que proporciona valiosa información, sólo comparable con la disección anatómica y por delante de pruebas como el Doppler de ultrasonidos y el eco Doppler color.The aim of this report, is to validate the Angio-CT technique with three-dimentional reconstruction as a preoperative planning tool, after comparison with Doppler ultrasound and color- Duplex. Between january 2006 and march 2007, we studied 11 consecutive patients (13 DIEP in whom a prospective comparative followed up was performed comparing, the findings observed using

  17. Vascular response to ischemia in the feet of falanga torture victims and normal controls--color and spectral Doppler findings

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Amris, Kirstine; Holm, Christian Cato

    2009-01-01

    to controls. On color Doppler this would be seen as less color after ischemia and on spectral Doppler as elevated resistive index (RI). METHODS: Ten male torture victims from the Middle East and nine age, sex and ethnically matched controls underwent Doppler examination of the abductor hallucis and flexor...... digitorum brevis muscles before and after two minutes ischemia induced with a pressure cuff over the malleoli. The color Doppler findings were quantified with the color fraction (CF) before and after ischemia. On spectral Doppler the resistive index was measured once before and three consecutive times after....... However, the trend in RI still supports the hypothesis. The negative findings may be due to inadequate design where the CF and RI were measured in one setting, perhaps resulting in both methods being applied imperfectly. The response to ischemia seems short-lived and we suggest that the Doppler methods...

  18. Application of Echocardiography on Transgenic Mice with Cardiomyopathies

    Directory of Open Access Journals (Sweden)

    G. Chen

    2012-01-01

    Full Text Available Cardiomyopathies are common cardiac disorders that primarily affect cardiac muscle resulting in cardiac dysfunction and heart failure. Transgenic mouse disease models have been developed to investigate the cellular mechanisms underlying heart failure and sudden cardiac death observed in cardiomyopathy cases and to explore the therapeutic outcomes in experimental animals in vivo. Echocardiography is an essential diagnostic tool for accurate and noninvasive assessment of cardiac structure and function in experimental animals. Our laboratory has been among the first to apply high-frequency research echocardiography on transgenic mice with cardiomyopathies. In this work, we have summarized our and other studies on assessment of systolic and diastolic dysfunction using conventional echocardiography, pulsed Doppler, and tissue Doppler imaging in transgenic mice with various cardiomyopathies. Estimation of embryonic mouse hearts has been performed as well using this high-resolution echocardiography. Some technical considerations in mouse echocardiography have also been discussed.

  19. Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins.

    Science.gov (United States)

    Sun, Xue; Zhang, Ying; Fan, Miao; Wang, Yu; Wang, Meilian; Siddiqui, Faiza Amber; Sun, Wei; Sun, Feifei; Zhang, Dongyu; Lei, Wenjia; Hu, Guyue

    2017-06-01

    Prenatal diagnosis of fetal total anomalous pulmonary vein connection (TAPVC) remains challenging for most screening sonographers. The purpose of this study was to evaluate the use of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation (4D-HDFI) in identifying pulmonary veins in normal and TAPVC fetuses. We retrospectively reviewed and performed 4D-HDFI in 204 normal and 12 fetuses with confirmed diagnosis of TAPVC. Cardiac volumes were available for postanalysis to obtain 4D-rendered images of the pulmonary veins. For the normal fetuses, two other traditional modalities including color Doppler and HDFI were used to detect the number of pulmonary veins and comparisons were made between each of these traditional methods and 4D-HDFI. For conventional echocardiography, HDFI modality was superior to color Doppler in detecting more pulmonary veins in normal fetuses throughout the gestational period. 4D-HDFI was the best method during the second trimester of pregnancy in identifying normal fetal pulmonary veins. 4D-HDFI images vividly depicted the figure, course, and drainage of pulmonary veins in both normal and TAPVC fetuses. HDFI and the advanced 4D-HDFI technique could facilitate identification of the anatomical features of pulmonary veins in both normal and TAPVC fetuses; 4D-HDFI therefore provides additional and more precise information than conventional echocardiography techniques. © 2017, Wiley Periodicals, Inc.

  20. Diagnosis of Cervical Abortion by TransvaginaI Color Doppler Sonography : A Case Report

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Ryu, Hee Sug; Ji, Hoon; Suh, Jung Ho

    1995-01-01

    Cervical abortion is a spontaneous abortion of an intrauterine pregnancy into the cervical canal where the abortus is retained by a closed external os, causing distension of the cervical canal. Cervical abortion should be distinguished from the cervical pregnancy. We present a case of cervical abortion diagnosed preoperatively by transvaginal sonography and color doppler imaging, and treated by dilatation and curettage. Charateristic transvaginal sonographic findings and identification of subtrophoblastic blood flow by color doppler imaging could allow differentiation of the cevical aborition from the cervical pregnancy

  1. Doppler Echocardiography Assessment of Aortic Stiffness in Female Adolescents with Anorexia Nervosa.

    Science.gov (United States)

    Escudero, Carolina A; Potts, James E; Lam, Pei-Yoong; De Souza, Astrid M; Mugford, Gerald J; Sandor, George G S

    2018-03-17

    Anorexia nervosa (AN) is associated with abnormalities in biomarkers of cardiovascular risk. Arterial stiffness, as measured by pulse-wave velocity (PWV), is also a risk factor for cardiovascular disease. The aims of this study were to determine the stiffness of the aorta in female adolescents with AN and to determine if either the severity or the type of AN was associated with PWV. This was a retrospective case-control study. Adolescent patients with a clinical diagnosis of AN were included. Aortic diameter and pulse-wave transit time over a portion of the thoracic aorta were measured using Doppler echocardiography, and PWV was calculated. There were 94 female patients with AN and 60 adolescent female control subjects. There was no significant difference in age between patients with AN and control subjects (15.5 ± 1.7 vs 15.1 ± 2.6 years, P = .220). Body mass index (16.0 ± 2.4 vs 19.7 ± 2.7 kg/m 2 , P study suggests that patients with AN may be at increased risk for future cardiovascular disease. Future studies are required to determine the reversibility of these changes with weight restoration. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  2. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  3. Healed perivalvular abscess: Incidental finding on transthoracic echocardiography

    Directory of Open Access Journals (Sweden)

    Vishnu Datt

    2014-01-01

    Full Text Available A 36-year-old male patient presented with the complaints of palpitations and breathlessness. Preoperative transthoracic echocardiography (TTE revealed a bicuspid aortic valve; severe aortic regurgitation with dilated left ventricle (LV and mild LV systolic dysfunction (ejection fraction 50%. He was scheduled to undergo aortic valve replacement. History was not suggestive of infective endocarditis (IE. Preoperative TTE did not demonstrate any aortic perivalvular abscess. Intraoperative transesophageal echocardiography (TEE examination using the mid-esophageal (ME long-axis view, showed an abscess cavity affecting the aortic valve, which initially was assumed to be a dissection flap, but later confirmed to be an abscess cavity by color Doppler examination. The ME aortic valve short-axis view showed two abscesses; one was at the junction of the non-coronary and left coronary commissure and the other one above the right coronary cusp. Intraoperatively, these findings were confirmed by the surgeons. The case report demonstrates the superiority of TEE over TTE in diagnosing perivalvular abscesses.

  4. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  5. Three-dimensional transesophageal echocardiography: Principles and clinical applications

    Directory of Open Access Journals (Sweden)

    Annette Vegas

    2016-01-01

    Full Text Available A basic understanding of evolving 3D technology enables the echocardiographer to master the new skills necessary to acquire, manipulate, and interpret 3D datasets. Single button activation of specific 3D imaging modes for both TEE and transthoracic echocardiography (TTE matrix array probes include (a live, (b zoom, (c full volume (FV, and (d color Doppler FV. Evaluation of regional LV wall motion by RT 3D TEE is based on a change in LV chamber subvolume over time from altered segmental myocardial contractility. Unlike standard 2D TEE, there is no direct measurement of myocardial thickening or displacement of individual segments.

  6. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma.

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reu, S; Deak, Z; Hetterich, H; Kolben, T; Reiser, M; Clevert, D A

    2014-01-01

    To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.

  7. Measurement of pulmonary arterial elastance in patients with systolic heart failure using Doppler echocardiography

    Science.gov (United States)

    Taghavi, Sepideh; Esmaeilzadeh, Maryam; Amin, Ahmad; Naderi, Nasim; Abkenar, Hooman Bakhshandeh; Maleki, Majid; Mitra, Chitsazan

    2016-01-01

    Objective: A reliable and easy-to-perform method for measuring right ventricular (RV) afterload is desirable when scheduling patients with systolic heart failure to undergo heart transplantation. The present study aimed to investigate the accuracy of echocardiographically-derived pulmonary arterial elastance as a measurement of pulmonary vascular resistance by comparing it with invasive measures. Methods: Thirty-one patients with moderate to severe systolic heart failure, including 22 (71%) male patients, with a mean age of 41.16±15.9 years were enrolled in the study. Right heart catheterization and comprehensive echocardiography during the first hour after completion of cardiac catheterization were performed in all the patients. The pulmonary artery elastance was estimated using the ratio of end-systolic pressure (Pes) over the stroke volume (SV) by both cardiac catheterization [Ea (PV)-C] and echocardiography [Ea (PV)-E]. Results: The mean Ea (PV)-C and Ea (PV)-E were estimated to be 0.73±0.49 mm Hg/mL and 0.67±0.44 mm Hg/mL, respectively. There was a significant relation between Ea (PV)-E and Ea (PV)-C (r=0.897, pechocardiography and catheterization methods for estimating Ea (PV), investigated by the Bland-Altman method, showed a mean bias of -0.06, with 95% limits of agreement from -0.36 mm Hg/mL to 0.48 mm Hg/mL. Conclusion: Doppler echocardiography is an easy, non-invasive, and inexpensive method for measuring pulmonary arterial elastance, which provides accurate and reliable estimation of RV afterload in patients with systolic heart failure. PMID:26467379

  8. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    Science.gov (United States)

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  9. Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Directory of Open Access Journals (Sweden)

    Sicari Rosa

    2005-01-01

    Full Text Available Abstract In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories.

  10. Spectral color Doppler in the diagnosis and follow-up of Graves' disease

    International Nuclear Information System (INIS)

    Sponza, Massimo; Bertolotto, Michele; Ricci, Claudio; Fabris, Bruno; Armini, Lorenzo

    1997-01-01

    Hyperthyroidism in Graves' disease is caused by the presence of circulating autoantibodies to the THS receptors on the thyroid cells. Thyroid-suppression therapy prevents hormone production directly, without affecting the pathogenetic process. They performed color Doppler US of the thyroid gland and pulsed Doppler analysis of thyroid artery flow in 21 patients with Graves' disease before and during medical treatment. US results were compared with those of a control group of 40 healthy subjects and correlated with the values of thyroid hormones, TSH and thyroid microsomal and thyroglobulin antibodies. The thyroid gland was hypo vascularized in the control group. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity of PSV 20 ± 4 cm/s, diastolic velocity of 8 ± 1 cm/s, and resistive index of 0.60 ± 0.04. The thyroid gland of Graves' disease patients was hyper vascularized. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity (PSV = 51 ± 12 cm/s), end diastolic velocity (VD = 15 ± 4 cm/s) and resistive index (RI = 0.71 ± 0.04) significantly higher than in normal subjects (p < 0.001). Circulating thyroid hormones and flow parameters normalized after 6-8 months of medical therapy (PSV = 20 ± 6 cm/s, VD = 9 ± 3 cm(s, RI = 0.58 ± 0.07). The color Doppler patterns normalized only in a patient with normal TSH and antibodies. Sampling of the thyroid arteries proved more repeatable than sampling of parenchymal vessels

  11. Echocardiography as an approach for canine cardiac disease diagnosis

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-11-01

    Full Text Available Aim: The aim of the study was to establish the methods for diagnosis various canine cardiac ailments using echocardiography. Materials and Methods: M-mode, two-dimensional echocardiography and Doppler studies were performed on 10 cases. Dogs showing signs of cardiac ailment either clinically, radiographic or via electrocardiographic examination were selected for study. Right parasternal short axis view was used for echocardiographic measurements. Right parasternal long axis and left parasternal apical views were used for Doppler studies. Doppler studies were performed at the level of aortic valve and atrioventricular valves for semi quantitative diagnosis of regurgitation. Results: Dogs were found affected with dilated cardiomyopathy (DCM (n=5, pericardial effusion (PE (n=1, combined PE and DCM (n=2 and remaining two showed abnormality on radiographic or electrographically evaluation but were found out to be normal echocardiographically (n=2. Conclusion: Echocardiography is an effective tool for diagnosis of various heart ailments.

  12. Role of color Doppler ultrasound in the diagnosis of nonpalpable ...

    African Journals Online (AJOL)

    excluded from the study. Color Doppler was performed in all cases, followed by laparoscopy. Further, findings on laparoscopy were compared with those of CDUS. A 95% confidence interval for the sensitivity of CDUS was estimated considering a positive result on CDUS as the binomial variable. Results. Out of 25 patients, ...

  13. Color Doppler Echocardiographic Assessment of Valvular Regurgitation in Normal Infants

    Directory of Open Access Journals (Sweden)

    Shu-Ting Lee

    2010-01-01

    Conclusion: The prevalence of inaudible valvular regurgitation is high in infants with structurally normal hearts. Multiple-valve involvement with regurgitation is not uncommon. Mild severity and low velocity on color Doppler, and the structural information provided by 2D imaging strongly suggest that these regurgitant flows are physiologically normal in infancy.

  14. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  15. [Current role of color Doppler ultrasound in acute renal failure].

    Science.gov (United States)

    Bertolotto, M; Quaia, E; Rimondini, A; Lubin, E; Pozzi Mucelli, R

    2001-01-01

    Acute Renal Failure (ARF) is characterized by a rapid decline of the glomerular filtration rate, due to hypotension (prerenal ARF), obstruction of the urinary tract (post-renal ARF) or renal parenchymal disease (renal ARF). The differential diagnosis among different causes of ARF is based on anamnesis, clinical symptoms and laboratory data. Usually ultrasound (US) is the only imaging examination performed in these patients, because it is safe and readily available. In patients with ARF gray scale US is usually performed to rule out obstruction since it is highly sensitive to recognize hydronephrosis. Patients with renal ARF have no specific changes in renal morphology. The size of the kidneys is usually normal or increased, with smooth margins. Detection of small kidneys suggests underlying chronic renal pathology and worse prognosis. Echogenicity and parenchymal thickness are usually normal, but in some cases there are hyperechogenic kidneys, increased parenchymal thickness and increased cortico-medullary differentiation. Evaluation of renal vasculature with pulsed Doppler US is useful in the differential diagnosis between prerenal ARF and acute tubular necrosis (ATN), and in the diagnosis of renal obstruction. Latest generation US apparatus allow color Doppler and power Doppler evaluation of renal vasculature up to the interlobular vessels. A significant, but non specific, reduction in renal perfusion is usually appreciable in the patients with ARF. There are renal pathologic conditions presenting with ARF in which color Doppler US provides more specific morphologic and functional information. In particular, color Doppler US often provides direct or indirect signs which can lead to the right diagnosis in old patients with chronic renal insufficiency complicated with ARF, in patients with acute pyelonephritis, hepatic disease, vasculitis, thrombotic microangiopathies, and in patients with acute thrombosis of the renal artery and vein. Contrast enhanced US is

  16. Color/power Doppler transrectal US in prostate cancer: Correlation with Gleason score

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Kim, Seung Hyup; Moon, Min Hoan; Park, Byung Kwan; Kim, Keon Ha; Choi, Hyuck Jae; Yoon, Chang Jin

    2002-01-01

    To evaluate the relationship between hypervascularity on color/power Doppler transrectal ultrasonography and the Gleason score of corresponding biopsied specimen in patients with prostatic cancer. From July 1998 to March 2002, one hundred fifty seven patients with pathologically proven prostate cancer at this institution were included, and all of them underwent transrectal ultrasonographic examination. Initially, ultrasonographic findings and pathologic data of 129 patients were retrospectively reviewed and excluded 28 patients whose sonographic images were either unavailable or inconclusive. The presence of hypoechoic lesion on transrectal sonography and hypervascularity on color/power Doppler sonography in the peripheral zone of the prostate was first evaluated, and these sonographic findings and Gleason score of the corresponding biopsied specimen were then compared. Statistical analysis was done by Student t-test using SPSS package. Among one hundred twenty nine patients, ninety four patients had a hypoechoic lesion on gray scale sonography while sixty one showed a hypervascular lesion on color/power Doppler sonography. Fifty seven of 61 patients (93.4%) had hypoechoic lesion on gray scale sonography. The mean Gleason score of patients with hypervascular lesion was 7.9 ± 0.98 whereas that of the patients without hypervascular lesion, 6.9 ± 1.22, showing a statistically significant difference (p<0.01). Prostate cancer with hypervascularity on transrectal sonography appears to have a higher Gleason score on pathologic examination than that without hypervascularity.

  17. Acute scrotal pathology in Schonlein-Henoch purpura: management by color Doppler ultrasound. A case report

    International Nuclear Information System (INIS)

    Jornet, J.; Cervera, J.; Marco, S.F.; Gonzalez, M.

    1998-01-01

    Schonlein-Henoch purpura is the most common form of purpura in children. It can affect a number of organs, but scrotal involvement is rare. We present a case of scrotal hemorrhage and epidymo-orchitis, diagnosed by color Doppler ultrasound, in which conservative treatment was employed. The differential diagnosis involves testicular torsion, which is also, although less frequently, associated with Schonlein-Henoch purpura. color Doppler ultrasound results in the correct diagnosis, ruling out testicular torsion and avoiding surgical exploration of the testicles. (Author) 8 refs

  18. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-10-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment.

  19. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-01-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment

  20. Evaluation of diagnosis of small breast cancer with high frequency and color doppler ultrasound

    International Nuclear Information System (INIS)

    Xia Guobing; Hu Chunhong; Jing Qiulong

    2008-01-01

    Objective: To probe the features of high frequency ultrasonography (HFU) and color Doppler ultrasound (CDU) in the case of small breast cancers in order to evaluate the diagnostic value for small breast cancer with CDU. Methods: The features of HFU and CDU were respective analyzed in 67 small breast masses, the biggest diameter of which was under 2cm identified with pathology. Results Partially characteristic changes of small breast cancers were displayed, and micro-calcification within the mass was an important characteristic, in addition, the Resistant Index (RI) ≥ 0.70 on Pulsed Doppler (PD) and the grade of blood flow on Color Doppler Flow Imaging (CDFI)≥T2 implied much more positive malignancy prediction. Conclusion: HFU integrated with CDU can be used for the early and accurate diagnosis of the small breast cancer. (authors)

  1. A feasability study of color flow doppler vectorization for automated blood flow monitoring.

    Science.gov (United States)

    Schorer, R; Badoual, A; Bastide, B; Vandebrouck, A; Licker, M; Sage, D

    2017-12-01

    An ongoing issue in vascular medicine is the measure of the blood flow. Catheterization remains the gold standard measurement method, although non-invasive techniques are an area of intense research. We hereby present a computational method for real-time measurement of the blood flow from color flow Doppler data, with a focus on simplicity and monitoring instead of diagnostics. We then analyze the performance of a proof-of-principle software implementation. We imagined a geometrical model geared towards blood flow computation from a color flow Doppler signal, and we developed a software implementation requiring only a standard diagnostic ultrasound device. Detection performance was evaluated by computing flow and its determinants (flow speed, vessel area, and ultrasound beam angle of incidence) on purposely designed synthetic and phantom-based arterial flow simulations. Flow was appropriately detected in all cases. Errors on synthetic images ranged from nonexistent to substantial depending on experimental conditions. Mean errors on measurements from our phantom flow simulation ranged from 1.2 to 40.2% for angle estimation, and from 3.2 to 25.3% for real-time flow estimation. This study is a proof of concept showing that accurate measurement can be done from automated color flow Doppler signal extraction, providing the industry the opportunity for further optimization using raw ultrasound data.

  2. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  3. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  4. Recent advances in echocardiography for nuclear medicine physician

    International Nuclear Information System (INIS)

    Hong, Geu Ru; Shin, Dong Gu

    2005-01-01

    Echocardiography is one of the most frequently used techniques for diagnosing cardiovascular diseases. Over the last twenty years, technological advances have enabled the application of high-quality imaging. Important recent developments have occurred in echocardiography that are already being used clinically. Equipment and hardware is now available to produce real time three-dimensional and contrast enhanced imaging. Tissue Doppler and stress echocardiography have provided potential benefit to analyze hemodynamic information of heart. This review discusses each of these new developments and their potential impact on the practice of echocardiography and cardiology in general

  5. A rare case of OEIS complex –newer approach to diagnosis of exstrophy bladder by color doppler and its differentiation from simple omphalocele

    Directory of Open Access Journals (Sweden)

    Kavita Aneja

    2017-01-01

    Full Text Available The objective of this article is to present a new approach to diagnose and differentiate similar ventral masses by color Doppler. Two cases of ventral masses, a rare case of OEIS complex (Omphalocele-exstrophy-imperforate anus-spinal defects with unusual presentation of exstrophy bladder and another of simple omphalocele, were studied by color Doppler for diagnosis and differentiation between the nature of similar masses. Ventral mass with absent bladder, normal kidneys, and normal amniotic fluid index raised the suspicion of exstrophy bladder. Color Doppler depicting altered intrafetal course of umbilical arteries and umbilical arteries coursing along the sides of ventral mass substantiated the diagnosis. The spatial relation between umbilical artery and aorta (which has no mention in the current literature in sagittal view has been identified as an acute angle in a normal fetus and coined as “K angle” arbitrarily by the author. Color Doppler reveals altered (widened “K angle” in exstrophy bladder compared to normal fetuses. Other combined anomalies pointed to the diagnosis of OEIS complex. The second case of simple omphalocele depicts normal intrafetal course of umbilical arteries and normal acute umbilical artery–aorta angle (K angle on color Doppler. Color Doppler aids the early diagnosis of ventral defects. New method by umbilical artery-aorta angle (K angle assessment on color Doppler helps differentiate exstrophy bladder from omphalocele.

  6. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients; Utilidad del Doppler color y pulsado en la valoracion de los shunts portosistemicos quirurgicos en la edad pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I. [Hospital Universitario La Paz. Madrid (Spain)

    2003-07-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs.

  7. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  8. Usefulness of color and pulsed Doppler's in the evaluation of surgical portosystemic shunts in pediatric patients

    International Nuclear Information System (INIS)

    Berrocal, T.; Prieto, C.; Cortes, P.; Rodriguez, R.; Pastor, I.

    2003-01-01

    Portosystemic shunts are performed to relieve symptomatic portal hypertension symptomatic or removal pressure in hepatic vascularisation in patients with Budd-Chiari's syndrome. Most surgical portosystemic shunts can be suitably studied by means of ultrasound scan complemented by color and pulsed Dopplers, proved one understands the hemodynamics of the surgical procedures involved. This article demonstrates the usefulness and limitations of the ultrasound scan Duplex Doppler in the evaluation of portosystemic shunts performed on pediatric patients. Pulsed Doppler provides information regarding the nature and direction of blood flow. Color doppler is capable of directly revealing the shunt and, in most cases, permits the anastomosis to be located. The types of shunts that appear include proximal and distal spleno-renal, portocaval and mesocaval. Types of vascular connections are illustrated,s well as expected post-surgical blood flow direction in affected vessels. The ultrasound scanning technique is discussed, as well as the criteria for determining vascular permeability. Also highlighted are the advantages, limitations and diagnostic difficulties associated with the different forms of Doppler. (Author) 17 refs

  9. Spectral color Doppler in the diagnosis and follow-up of Graves` disease; Ruolo dell`eco color Doppler e dell`analisi flussimetrica nella diagnosi e nel follow-up della malattia dei Graves

    Energy Technology Data Exchange (ETDEWEB)

    Sponza, Massimo; Bertolotto, Michele; Ricci, Claudio [Ospedale di Cattinara, Trieste (Italy). Istituto di Medicina Clinica; Fabris, Bruno; Armini, Lorenzo [Ospedale di Cattinara, Trieste (Italy). Istituto di Radiologia

    1997-04-01

    Hyperthyroidism in Graves` disease is caused by the presence of circulating autoantibodies to the THS receptors on the thyroid cells. Thyroid-suppression therapy prevents hormone production directly, without affecting the pathogenetic process. They performed color Doppler US of the thyroid gland and pulsed Doppler analysis of thyroid artery flow in 21 patients with Graves` disease before and during medical treatment. US results were compared with those of a control group of 40 healthy subjects and correlated with the values of thyroid hormones, TSH and thyroid microsomal and thyroglobulin antibodies. The thyroid gland was hypo vascularized in the control group. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity of PSV 20 {+-} 4 cm/s, diastolic velocity of 8 {+-} 1 cm/s, and resistive index of 0.60 {+-} 0.04. The thyroid gland of Graves` disease patients was hyper vascularized. Pulsed Doppler examination of the thyroid arteries exhibited peak systolic velocity (PSV = 51 {+-} 12 cm/s), end diastolic velocity (VD = 15 {+-} 4 cm/s) and resistive index (RI = 0.71 {+-} 0.04) significantly higher than in normal subjects (p < 0.001). Circulating thyroid hormones and flow parameters normalized after 6-8 months of medical therapy (PSV = 20 {+-} 6 cm/s, VD = 9 {+-} 3 cm/s, RI = 0.58 {+-} 0.07). The color Doppler patterns normalized only in a patient with normal TSH and antibodies. Sampling of the thyroid arteries proved more repeatable than sampling of parenchymal vessels.

  10. Pulsed and Color Doppler Sonographic Findings of Penile Mondor' Disease

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hye Yeon; Chung, Dong Jin; Kim, Kum Won; Hwang, Cheol Mog [University of Konyang School of Medicine, Daejeon (Korea, Republic of)

    2008-04-15

    Penile Mondor's disease is a rare disease that's characterized by thrombosis in the dorsal vein of the penis. Doppler ultrasonography (US) clearly visualizes dorsal vein thrombosis and the associated hemodynamic alterations. Previous studies have demonstrated the typical color Doppler US findings of superficial dorsal vein thrombosis without the flow signals in this area, yet this is insufficient to understand the hemodynamics in penile Mondor's disease. We report here for the first time a cavernosal artery flow signal pattern in a penile Mondor's disease patient, in addition to its previously reported classic US findings. In conclusion, the Doppler US findings of thrombus without blood flow in the superficial dorsal vein and the low-flow, high resistance in the cavernosal artery may be suggestive of penile Mondor's disease.

  11. [Pulmonary artery pressure evaluation in adults by Doppler echocardiography].

    Science.gov (United States)

    Campos Filho, O; Andrade, J L; Carvalho, A C; Luna Filho, B; Pfeferman, A; Arroyo, J B; Leão, L E; Martinez Filho, E E

    1991-04-01

    To assess the role of pulsed Doppler echocardiography (PDE) in the indirect assessment of pulmonary artery (PA) pressure (P), analysing the pulmonary velocity blood flow curves (PVBFC) profile. Sixty-one adults with several kinds of heart disease were submitted to heart catheterization to obtain PAP (systolic, diastolic, mean), and other hemodynamic variables. A PDE examination was performed in all to obtain the PVBFC at the level of the pulmonic annulus. Qualitative features of the curve were analysed (morphological pattern, presence of pulmonic regurgitation) as well as quantitative data (acceleration time = AT, right ventricle ejection time = RVET index, AT/RVET index AT corrected for heart rate = ATC), which were compared to the invasive measurements. An abnormal rapid acceleration of the PVBFC, with triangular configuration, was noted in patient with pulmonary hypertension (PH), in contrast to the dome-like shape of the PVBFC in normal PAP. Pulmonary regurgitation was more frequent (p less than 0.05) in patients with severe PH (mean PAP greater than or equal to 40 mmHg), comparing with patients with PAP less than 40 mmHg. Inverse linear correlations were observed between AT and mean PAP, particularly when sinus rhythm was present (r = 0.89; p less than 0.05) excluding patients with atrial fibrilation (19 cases). PDE is an useful and noninvasive method for indirect evaluation of PAP in adults, especially during stable sinus rhythm, in heart rate range from 60 to 115 bpm.

  12. Cow's milk allergy: color Doppler ultrasound findings in infants with hematochezia.

    Science.gov (United States)

    Epifanio, Matias; Spolidoro, Jose Vicente; Missima, Nathalia Guarienti; Soder, Ricardo Bernardi; Garcia, Pedro Celiny Ramos; Baldisserotto, Matteo

    2013-01-01

    ultrasound (US) has been an important diagnostic tool to identify several causes of gastrointestinal bleeding. Infants with cow's milk allergy (CMA) may present hematochezia and the confirmation of the diagnosis can be difficult. The aim of this study is to describe grayscale and color Doppler ultrasound findings in patients with CMA. we retrospectively studied 13 infants with CMA. All infants presented severe hematochezia and abdominal pain. All underwent an US study with the diagnosis of allergic colitis. This diagnosis was based on clinical findings, recovery after infant or mother exclusion diets in the case of exclusive breastfeeding and positive oral challenge test. the mean age ranged from 1 to 6 months (mean=3.53). Seven out of 13 infants (53.8%) had grayscale and color Doppler sonographic repeated after exclusion diet. Twelve out of 13 (92,3%) showed abnormalities at US and CDUS at beginning. The positive findings suggesting colitis were thickened bowel walls and increased vascularity, especially in the descending and sigmoid colon. Colonoscopy and histopathological findings were compatible with allergic colitis. After a diet change the 13 infants recovered and their oral challenge tests were positive. Doppler US may be very useful in diagnosing secondary colitis, such as CMA, and to exclude several other abdominal diseases that can emulate this disease. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  13. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Evaluation of aortic regurgitation using cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tamai, Takuya; Konishi, Tokuji; Okamoto, Shinya; Sakuma, Hajime; Takeda, Kan; Nakano, Takeshi

    1993-01-01

    Cine magnetic resonance imaging (MRI) was used to assess aortic regurgitation (AR) in 13 patients with valvular disease and 3 normal subjects, and the results were compared to color Doppler flow mapping findings. AR produced a signal void in the left ventricle during the diastolic phase in all patients by MRI. There were no false positive or negative results compared with echocardiographic findings. Visual grading of cine MRI gave results similar to color flow Doppler echocardiography (88%). The distance and the area of aortic regurgitation using MRI correlated well with color Doppler flow mapping (r=0.82 and 0.88). However, measurements of distance and area by color flow Doppler tended to be larger than those by cine MRI. With current techniques echocardiography may overestimate the severity of AR as compared with cine MRI. In addition, MRI gives clinically useful information in patients in whom transthoracic Doppler echocardiography is not adequate. (author)

  15. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  16. Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures

    International Nuclear Information System (INIS)

    Ahmed, I.; Nuri, M. M. H.; Zakariyya, A. N.; Ahmad, S. M.; Ahmed, M.

    2016-01-01

    Objective: To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. Methodology: All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. Results: Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ± 15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ± 13.05) and diagnostic accuracy (79%). Conclusion: Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal. (author)

  17. The Efficacy of Magnetic Resonance Imaging and Color Doppler Ultrasonography in Diagnosis of Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    Behrooz Davachi

    2014-12-01

    Full Text Available Background and aims. Although salivary gland tumors are not very common, early diagnosis and treatment is crucial because of their proximity to vital organs, and therefore, determining the efficacy of new imaging procedures becomes important. This study aimed to evaluate the efficacy of magnetic resonance imaging (MRI and color doppler ultrasonography parameters in the diagnosis and differentiation of benign and malignant salivary gland tumors. Materials and methods. In this cross-sectional study, color doppler ultrasonography and MRI were performed for 22 patients with salivary gland tumor. Demographic data as well as MRI, color doppler ultrasonography, and surgical parameters including tumor site, signal in MRI images, ultrasound echo, tumor border, lymphadenopathy, invasion, perfusion, vascular resistance index (RI, vascular pulse index (PI were analyzed using Chi-square test, Fisher’s exact test, and independent ttest. Results. The mean age of patients was 46.59±13.97 years (8 males and 14 females. Patients with malignant tumors were older (P < 0.01. The most common tumors were pleomorphic adenoma (36.4%, metastasis (36.4%, and mucoepidermoid carcinoma (9%. Nine tumors (40.9% were benign and 13 (59.1% were malignant. The overall accuracy of MRI and color doppler ultrasonography in determining tumor site was 100% and 95%, respectively. No significant difference observed between RI and PI and the diagnosis of tumor. Conclusion. Both MRI and ultrasonography have high accuracy in the localization of tumors. Well-identified border was a sign of benign tumors. Also, invasion to adjacent structures was a predictive factor for malignancy.

  18. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  19. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  20. Choroid metastasis of papillary thyroid carcinoma. Color doppler ultrasound study

    International Nuclear Information System (INIS)

    Ganado, T.; Torre, S. de la; Contreras, E.; Hernandez, J.

    1997-01-01

    The most common causes of intraocular metastases are breast and lung cancers, although many other neoplasms can metastasize to the eye. Most of the metastases are located in the posterior pole and the choroid is more often involved than the retina. We present a case of a choroidal metastasis from a papillary carcinoma of the thyroid, associated with a massive subretinal hemorrhage. Findings with color Doppler ultrasound are emphasized. (Author) 9 refs

  1. The Diagnostic Value of Transvaginal Sonograph (TVS), Color Doppler, and Serum Tumor Marker CA125, CEA, and AFP in Ovarian Cancer.

    Science.gov (United States)

    Zhang, Fang; Zhang, Zhou-Long

    2015-06-01

    The purpose of this study is to investigate the diagnostic value of transvaginal sonograph (TVS), color Doppler, and serum tumor marker CA125, CEA, and AFP in ovarian cancer. From June, 2011 to May, 2013, 102 cases with adnexal mass were recruited in this study (32 cases of malignant ovarian cancer and 70 cases of benign ovarian tumor according to pathological diagnosis). TVS, color Doppler, and serum tumor markers were used for tumor diagnosis. The sensitivity, specifity, positive prediction, negative prediction, and Youden's index were analyzed. Of the 102 patients, 32 were diagnosed with malignant ovarian cancer and 70 were diagnosed with benign ovarian tumor according to pathological diagnosis. Based on TVS results, 37 cases were malignant while 65 cases were benign. Based on color Doppler results, 34 cases were malignant while 68 cases were benign. Based on TVS and color Doppler results, 35 cases were malignant while 65 were benign. Based on CA125 test results, 34 cases were malignant while 68 cases were benign. Based on CEA test results, 8 cases were malignant and 94 cases were benign. Bases on AFP test results, 9 cases were malignant while 93 cases were benign. Based on the results of combination tumor marker test, 38 cases were malignant while 64 cases were benign. The combination of TVS, color Doppler, and tumor marker test showed optimal diagnostic value with a sensitivity of 90.63 %, specificity of 97.14 %, positive prediction of 93.94 %, negative prediction of 98.55 %, and Youden's index of 94.02 %. The combination of TVS, color Doppler, and tumor marker test is of great diagnostic value, which should be widely used in clinical practice.

  2. Cardiac output by Doppler echocardiography in the premature baboon: Comparison with radiolabeled microspheres

    International Nuclear Information System (INIS)

    Kinsella, J.P.; Morrow, W.R.; Gerstmann, D.R.; Taylor, A.F.; deLemos, R.A.

    1991-01-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). The authors conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress

  3. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  4. Color-flow Doppler imaging in suspected extremity venous thrombosis

    International Nuclear Information System (INIS)

    Foley, W.D.; Middleton, W.D.; Lawson, T.L.; Hinson, G.W.; Puller, D.R.

    1987-01-01

    Color-flow Doppler imaging (CFDI) (Quanatum, 5 and 7.5 MHz, linear array) has been performed on 23 extremities (nine positive for venous thrombosis, 14 negative) with venographic correlation. CFDI criteria evaluated were venous color-flow respiratory variation, augmentation, compressibility, valve competence, and intraluminal echogenic filling defects. Both CFDI and venography were evaluated independently and prospectively. CFDI and venography agreed in all six cases of femoral vein thrombosis and eight of nine cases of popliteal vein thrombosis. CFDI was negative in one instance of recanalized popliteal vein thrombosis. Recanalized femoral vein thrombosis was documented in three patients by CFDI when the vein was nonopacified on conventional venography. CFDI provides a rapid and accurate assessment of the femoral popliteal venous system and can distinguish an occluded from a recanalized thrombus. Initial experience with auxiliary subclavian venous thrombus has produced equally accurate results

  5. Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2008-01-01

    Full Text Available Abstract Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures.

  6. Tissue Doppler echocardiography in persons with hypertension, diabetes, or ischaemic heart disease: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Mogelvang, Rasmus; Sogaard, Peter; Pedersen, Sune A

    2009-01-01

    AIMS: To test the hypothesis that echocardiographic tissue Doppler imaging (TDI) reveals reduced myocardial function in hypertension, diabetes, and ischaemic heart disease (IHD) in the general population. METHODS AND RESULTS: Within a large, community-based population study, cardiac function...... and diastolic cardiac function in hypertension [n = 345; LD 10.1 (+/-standard deviation, SD 2.0 mm), P diabetes [n = 65; LD 9.8 (+/-SD 2.2 mm), P ....001] compared with controls [n = 533; LD 11.4 (+/-SD 2.0 mm); E/e' 9.0 (x/SD 1.3)]. This pattern remained significant after adjusting for age, sex, body mass index, heart rate, and the results of conventional echocardiography. CONCLUSION: In the general population, persons with hypertension, diabetes, or IHD...

  7. Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

    Directory of Open Access Journals (Sweden)

    Elzivânia G. Silva

    Full Text Available ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1, anterior chamber depth (M2, lens thickness (M3, lens length (M4, vitreous chamber depth (M5, optical disc length (M6 and optic nerve diameter (M7. Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS, final diastolic velocity (VDF, resistivity index (IR and pulse index (IP. No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05. The vitreous chamber depth (M5 was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05. The mean resistivity index (RI showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities

  8. Feasibility of transesophageal echocardiography in birds without cardiac disease.

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Nevarez, Javier G; Tully, Thomas N

    2010-03-01

    To establish a technique of transesophageal echocardiography (TEE) in birds without cardiac disease and describe the imaging planes obtained. Validation study. 18 birds including 3 pigeons (Columbia livia), 3 barred owls (Strix varia), 2 red-tailed hawks (Buteo jamaicensis), 1 goose (Anser anser), 1 mallard duck (Anas platyrhynchos), 1 Muscovy duck (Cairina moschata), 2 brown pelicans (Pelecanus occidentalis), 2 Hispaniolan Amazon parrots (Amazona ventralis), 2 red-fronted macaws (Ara rubrogenys), and 1 military macaw (Ara militaris). For each bird, anesthesia was induced and maintained by use of isoflurane. A pediatric, multiplane transesophageal ultrasound probe was passed into the esophagus and adjusted to the level of the heart for echocardiography. Probe positions were recorded via fluoroscopy, and associated imaging planes were described. TEE was performed successfully in all birds except the pelicans, 1 Hispaniolan Amazon parrot, and the red-fronted macaws. Five imaging planes of the heart were consistently viewed from 3 positions of the probe (identified as caudal, middle, and cranial positions relative to the cardiac silhouette). M-mode echocardiography of the left ventricle and the aortic root was performed. Color flow and spectral Doppler ultrasonographic images of in- and outflow regions were obtained. One Hispaniolan Amazon parrot died as a result of esophageal perforation. TEE examination of birds was feasible and provided a larger number of imaging planes with better resolution and details than those typically achieved via a transcoelomic approach. However, TEE should be performed with caution in psittacines.

  9. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  10. Usefulness of hemodynamically distribution of intranodal vessels in differentiating metastatic neck lymph nodes-value of color doppler and spectral wave sonogram

    International Nuclear Information System (INIS)

    Mumtaz, U.

    2017-01-01

    Objective: To evaluate the diagnostic assessment of enlarged lymph nodes, based on its perfusion pattern by taking tissue diagnosis as gold standard. Study Design: Analytical study. Place and Duration of Study: Departments of Radiology and Pathology, PIMS Hospital, Islamabad, from February to May 2016. Methodology: Color sonography of patients with clinically, palpable cervical lymph nodes were carried by senior trainee under the supervision of senior radiologist. Ultrasound guided tissue diagnosis was obtained in all suspected malignant cases. Histopathology was taken as the gold standard for determining accuracy. Results: Accuracy, sensitivity and specificity, positive and negative predictive values of color Doppler ultrasound in detecting malignant cervical lymphadenopathy was found to be 88.46%, 86.05%, 79.31% and 92.50%, respectively with diagnostic accuracy of 86.95%, when intranodal vascular pattern on color Doppler imaging was analyzed. Using spectral wave indexes, the same values were 92.31%, 90.70%, 85.71%, 95.12%, respectively with overall diagnostic accuracy of 91.30%. Conclusion: Color Doppler sonography is much sensitive borderline than grey scale findings alone. Furthermore, lymph nodes appearing in the detection of malignant nodes on grey scale images can be reliably diagnosed on Doppler scan. (author)

  11. TORSION TESTIS : ROLE OF COLOR DOPPLER : A STUDY OF 50 CASES

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND: T orsion testis is one of the catast r ophic conditions in children and young a d u lts. Traditionally the diagnosis was made clinical presentation and suspicion. Critical decision making is essential to save the testis . OBJECTIVE: To study the usefu lness and efficacy of Doppler ultrasound in correctly diagnosing acute scrotal conditions in children and young adults to save the testis and to avoid negative explorations. METHODS: Over a period of two years 50 patients with acute scrotum were admitted i n general surgery department who underwent Doppler ultrasound scrotum and its efficacy in correctly diagnosing the pathology was analysed. RESULTS: 50 patients with age group <25 years were included in study. Scrotal pain was the most frequent presenting s ymptom of acute scrotum (98% followed by Swelling of the hemiscrolum on the involved side present in 86% of the patients. Doppler ultrasound showed torsion of testis in 18 patients. On Scrotal exploration, torsion of spermatic cord was confirmed in 16 pat ients, one patient had torsion of appendix of testis and the other had Epididymo - orchitis. Thus the sensitivity and specificity of Doppler ultrasonography for testicular torsion was 86.9% and 92.6% respectively. 2 patients with equivocal Doppler findings, but strong clinical suspicion of testicular torsion were explored, and testis was found to be torsed in both two patients. Doppler ultrasonography showed Epididymo - orchitis in 22 patients, torsion of testicular appendage in 2 patients, Idiopathic scrotal edema in one, and in 5 pts no significant pathology found. All twenty patients of epididymo - orchitis, two patients of torsion of testicular appendage, and one patient of idiopathic scrotal edema were managed conservatively. At three weeks follow up, all th e patients were free of symptoms. The sensitivity and specificity of Doppler ultrasonography for epididymo - orchitis was 95% and 100% respectively. CONCLUSIONS: color

  12. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  13. Twinkling artifact on color Doppler ultrasound: an advantage or a pitfall?

    Science.gov (United States)

    Ozan, Ebru; Atac, Gokce Kaan; Gundogdu, Sadi

    2016-07-01

    The twinkling artifact (TA) or color comet-tail artifact is characterized by a rapidly changing mixture of red and blue color Doppler signals. Even though many diseases and clinical conditions have been shown to produce this artifact, its source is not clearly understood yet. The TA may provide additional information to gray-scale ultrasound findings in several clinical situations. However, there may be pitfalls to keep in mind. We must first be aware of the TA to benefit from the advantages and avoid the pitfalls. In this review, we aim to give practicing radiologists an overview of the mechanisms and clinical applications of the TA by illustrating sample cases we have encountered.

  14. Novel techniques in stress echocardiography: a focus on the advantages and disadvantages.

    Science.gov (United States)

    Vamvakidou, Anastasia; Gurunathan, Sothinathan; Senior, Roxy

    2016-01-01

    Stress echocardiography (SE) is an established tool not only for the assessment of coronary artery disease (CAD), but also for the evaluation of valvular disease and cardiomyopathy. New techniques, namely contrast echocardiography for function and perfusion including assessment of coronary flow reserve, strain imaging, 3-dimensional echocardiography, Doppler-derived coronary flow reserve and multimodality echocardiography, have been incorporated into stress protocols for improving assessment of cardiac disease. In this review, the advantages and disadvantages of these novel SE techniques are examined in terms of feasibility, accuracy, reproducibility and applications.

  15. [Doppler echocardiography of tricuspid insufficiency. Methods of quantification].

    Science.gov (United States)

    Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P

    1994-01-01

    Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.

  16. Corpus luteum blood flow in normal and abnormal early pregnancy: evaluation and analysis with transvaginal color and pulsed doppler sonography

    International Nuclear Information System (INIS)

    Tang Xiaoyi; Lin Meifang; Zheng Meirong; Liang Xiaoxian; Liu Jianfeng

    2005-01-01

    Objective: Detecting and assessment the corpus luteum blood flow in normal and abnormal early pregnancy. Methods: Using transvaginal color and pulse Doppler sonography, we detected 215 pregnant women including 150 normal intrauterine pregnancies, 25 abortion, 29 ectopic pregnancies, and then recorded corpus luteum blood flow feature and the blood flow indexes (Vmax, RI and PI). Results: 1) Corpus luteum was successfully identified in 148 cases out of 150 of normal early pregnancies, 25 cases out of 26 of threatened abortion; 22 cases out of 29 of ectopic pregnancy. 2) Three groups shared the same feature of Color Doppler imaging: a circumferential rim around the entire corpus luteum. 3) The flow index revealed mean PVS, RI and PI had no statistical difference in normal and abnormal early pregnancy; The mean PVS was lower in ectopic pregnancy than in normal pregnancy (P<0.05), while PI and PR had no characteristic in ectopic pregnancy group compared with the indexes obtained in normal pregnancy group. Conclusion: The corpus luteum can be precisely identified in most pregnancy using transvaginal color Doppler and manifests a characterized rim Doppler imaging. PVS may help in differentiating the ectopic pregnancy from normal early pregnancy. (authors)

  17. Color Doppler ultrasound evaluation of asphyxial neonatal left ventricular function and its correlation with target organ damage

    Directory of Open Access Journals (Sweden)

    Cheng-Cai Chen

    2017-01-01

    Full Text Available Objective: To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage. Methods: Normal neonates, mildly asphyxial neonates and severely asphyxial neonates born in our hospital between January 2014 and December 2015 were selected as the control group (n = 46, mild asphyxia group (n = 37 and severe asphyxia group (n = 23 respectively. On the 1st day after birth, color Doppler ultrasound was used to evaluate left ventricular function, and serum was collected to determine myocardial tissue injury, brain tissue injury and brain tissue metabolism indexes. Results: Color Doppler ultrasound parameters cardiac output (CO, ejection fraction (EF and left ventricular fraction shortening (FS as well as serum folate and vitamin B12 content of mild asphyxia group and severe asphyxia group were significantly lower than those of control group (P<0.05 while serum creatine kinase isoenzyme (CK-MB, troponin I (cTnI, troponin T (cTnT, S100B, neuron-specific enolase (NSE, creatine kinase BB (CK-BB, glycogen phosphorylase BB (GPBB, and homocysteine (Hcy content were significantly higher than those of control group (P<0.05; CO, FS and EF as well as serum folate and vitamin B12 content of severe asphyxia group were significantly lower than those of mild asphyxia group (P<0.05 while serum CK-MB, cTnT, cTnI, S100B, NSE, CK-BB, GPBB and Hcy content were significantly higher than those of mild asphyxia group (P<0.05. Conclusions: Color Doppler ultrasound can accurately assess asphyxial neonatal left ventricular function damage degree and is closely related to myocardial tissue injury and brain tissue injury degree.

  18. Color doppler flow imaging in evaluation of uterine arterial embolization of leiomyoma with KMG

    International Nuclear Information System (INIS)

    Li Furong; Guo Yunhuai; Liu Lifang; Liu Jianhua; Guo Yunhuai

    2006-01-01

    Objective: To explore the effectiveness of a new kind of embolization agent-sodium alginate(KMG), and to evaluate the clinical value of 2D color Doppler ultrasound in assessing the therapeutic effect of uterine arterial embolization (UAE) in leiomyomas. Methods: Forty nine patients with symptomatic leiomyomas were undertaken UAE with KMG for the treatment. Sonography was performed at 3-7 days before and, 1, 3, 6 months after UAE with 2D color Doppler for evaluating the 2D echograms and hemodynamics. Results: Forty nine leiomyomas were studied after UAE, showing a marked reduction in the size (35%-90%). No blood flow was demonstrated in the leiomyomas either 3-7 days or 1 month or 3 months after the procedure. The reappearance of blood flow could be seen in only one case. Conclusion: KMG is an efficient embolization agent for the treatment of symptomatic leiomyomas with UAE, and ultrasonography is a useful tool to assess the effectiveness. (authors)

  19. Diagnosis of post-partum ovarian vein thrombophlebitis by color Doppler ultrasonography: about 10 cases.

    Science.gov (United States)

    Giraud, J R; Poulain, P; Renaud-Giono, A; Darnault, J P; Proudhon, J F; Grall, J Y; Mocquet, P Y

    1997-09-01

    Post-partum ovarian vein thrombosis is often overlooked or mistaken for other complications such as endometritis. Color Doppler ultrasonography is a very good diagnostic method when properly indicated and correctly interpreted according to clinical data. This study reports ten cases that were retrospectively studied, during which color Doppler ultrasonography was used. The clinical signs and the results are reviewed. The lesions were clearly visualized in eight of the ten cases; one of the two failures resulted from a methodological fault (uninterpretable result); the other one was due to the lack of experience of the operator and nonrecognition of the clinical signs. Thrombosis appears as a hypoechogenic and tubular image. This type of examination is particularly indicated in the presence of certain clinical signs that were observed in our cases: fever and iliac pain are the main precursor signs, often associated with abdominal meteorism and slow digestive transit; provoked cul-de-sac pain during vaginal probing was the only constant sign, sometimes associated with painful swelling.

  20. Value of downstream circulation in renal artery stenosis with arterial hypertension: comparison between color Doppler flow and digital renal angiography in 123 patients

    International Nuclear Information System (INIS)

    Grataloup, C.; Challande, P.; Plainfosse, M.C.; Girerd, X.; Belattar, K.; Plouin, P.F.

    1996-01-01

    Digital renal angiography and color Doppler flow were compared for diagnosis of renal artery stenosis in 123 hypertensive patients with a prevalence of renal artery stenosis ≥75% of 21 %. Only color Doppler flow signs found downstream from the stenosis could be quantified. A rising time (RT) >0.07 s was the best marker for renal artery stenosis ≥ 75 % according to a receiver operating characteristic curve with a specificity of 97 %, a sensitivity of 88 %, a positive predictive value of 86 %, a negative predictive value of 98 % and an accuracy of 96 %. Digital renal angiography and color Doppler flow findings for renal artery lesions were classified into 4 degrees with agreement for 86 % of the kidneys. (authors). 13 refs., 5 figs., 8 tabs

  1. MRI and echocardiography in the diagnosis of cardiac amyloidosis

    International Nuclear Information System (INIS)

    Wang Jing; Kong Xiangquan; Zhou Guofeng; Xu Haibo; Chang Dandan; Feng Yiming; Liu Dingxi; Zhang Li; Xie Mingxing

    2010-01-01

    Objective: To assess the values of MRI and echocardiography for the diagnosis of cardiac amyloidosis (CA). Methods: Eleven cases with CA proved pathologically performed MRI and echocardiography, the findings were analyzed retrospectively. Results: The characteristic features of cardiac amyloidosis on MRI and echocardiography were: diffuse slight myocardial thickening of the left ventricular wall and interventricular septum (11 cases), slight myocardial thickening of the interatrial septum (5 cases), increased left ventricular mass (7 cases), enlarged left atrium (7 cases), impaired ventricular systolic and diastolic function (10 cases), pleural and pericardial effusions (11 and 9 cases). Echocardiography showed that myocardium was hyperechoic and presented as ground glass with some spotty hyperechoes in 6 cases. MRI revealed a distinct diffuse delayed enhancement of subendocardial and entire myocardium in 8 cases. Conclusion: Doppler echocardiography is the first-choice imaging technique and cardiac magnetic resonance imaging can provide more information for the diagnosis of CA. (authors)

  2. Associations between thoracic radiographic changes and severity of pulmonary arterial hypertension diagnosed in 60 dogs via Doppler echocardiography: A retrospective study.

    Science.gov (United States)

    Adams, Dustin S; Marolf, Angela J; Valdés-Martínez, Alejandro; Randall, Elissa K; Bachand, Annette M

    2017-07-01

    Doppler echocardiography is a noninvasive method for estimating and grading pulmonary arterial hypertension. No current literature associates significance of radiographic findings with severity of pulmonary arterial hypertension. We hypothesized that the number and conspicuity of radiographic findings suggestive of pulmonary arterial hypertension would be greater based on the severity of pulmonary arterial hypertension. Dogs with pulmonary arterial hypertension and normal control dogs were included in this retrospective, case control study. Three radiologists blinded to echocardiographic results scored thoracic radiographs for right ventricular and main pulmonary artery enlargement and pulmonary lobar artery enlargement, tortuosity, and blunting by multiple methods. Presence or absence of each finding was scored in an additive fashion and averaged for each grade of pulmonary arterial hypertension severity. Seventy-one dogs (60 dogs with pulmonary arterial hypertension and 11 control dogs) of which some had multiple studies were included: 20 mild, 21 moderate, 25 severe, and 11 absent pulmonary arterial hypertension. The following radiographic findings were significantly associated with increasing pulmonary arterial hypertension severity: right ventricular enlargement by "reverse D" and "3/5-2/5 cardiac ratio" methods, main pulmonary artery enlargement, and caudal lobar artery enlargement by the "3rd rib" method. Mean scores for severe pulmonary arterial hypertension and normal dogs were significantly different (P-value < 0.0001). Mean scores between different pulmonary arterial hypertension grades increased with severity but were not statistically significant. Individually and in combination, radiographic findings performed poorly in differentiating severity of pulmonary arterial hypertension. Findings indicated that thoracic radiographs should be utilized in conjunction with Doppler echocardiography in a complete diagnostic work-up for dogs with suspected

  3. [Usefulness of transvaginal Doppler color in ovarian neoplasms diagnosis].

    Science.gov (United States)

    Muñoz, H; Martínez, L; Parra, M; Cunill, E; Polanco, M; Leible, S; Romero, C

    1993-01-01

    The vascular resistant evaluation by Doppler waveform is a method used in clinic and research. The neoplastic malignant has an increased growth with an increased amount of neomalignant vessels. The presence of these vessels produce an increase of the transversal section area from the tumoral vascular system, therefore there is a decrease in the vascular resistance. The main objective of this work is to show the usefulness of Doppler waveform as predictor factor of malignity in ovary tumors. Eighteen patients with tumoral mass in the ovary were studied. They were between 21 and 67 years old (mean = 43). The tumoral volume and the flow resistance of blood vessels which irrigated those tumoral mass were evaluated by transvaginal ultrasound with color and pulsed Doppler. The pulsatility index (SD/media) was used. The Chi cuadrado test was used to evaluate the results. The results show the presence of six malignant tumors, three of them with low malignicity and the presence of twelve benign tumors. The age of the patients between both groups (malignant and benign tumors) were significant different (40.7 versus 52 years old, p < 0.001). The mean tumoral volume was 65 ml, with a range of 17 to 225 ml in the group of patients with benign tumors and the mean tumoral volume from patients with malignant tumors was 951 ml with a range of 141 to 3142 ml. The difference in the tumoral in both groups was significative with p < 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    Science.gov (United States)

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  5. High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography

    NARCIS (Netherlands)

    van Leeuwen, T. G.; Kulkarni, M. D.; Yazdanfar, S.; Rollins, A. M.; Izatt, J. A.

    1999-01-01

    Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on

  6. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    Science.gov (United States)

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  7. Utility of Angle Correction for Hemodynamic Measurements with Doppler Echocardiography.

    Science.gov (United States)

    Sigurdsson, Martin I; Eoh, Eun J; Chow, Vinca W; Waldron, Nathan H; Cleve, Jayne; Nicoara, Alina; Swaminathan, Madhav

    2018-04-06

    The routine application angle correction (AnC) in hemodynamic measurements with transesophageal echocardiography currently is not recommended but potentially could be beneficial. The authors hypothesized that AnC can be applied reliably and may change grading of aortic stenosis (AS). Retrospective analysis. Single institution, university hospital. During phase I, use of AnC was assessed in 60 consecutive patients with intraoperative transesophageal echocardiography. During phase II, 129 images from a retrospective cohort of 117 cases were used to quantify AS by mean pressure gradient. A panel of observers used custom-written software in Java to measure intra-individual and inter-individual correlation in AnC application, correlation with preoperative transthoracic echocardiography gradients, and regrading of AS after AnC. For phase I, the median AnC was 21 (16-35) degrees, and 17% of patients required no AnC. For phase II, the median AnC was 7 (0-15) degrees, and 37% of assessed images required no AnC. The mean inter-individual and intra-individual correlation for AnC was 0.50 (95% confidence interval [CI] 0.49-0.52) and 0.87 (95% CI 0.82-0.92), respectively. AnC did not improve agreement with the transthoracic echocardiography mean pressure gradient. The mean inter-rater and intra-rater agreement for grading AS severity was 0.82 (95% CI 0.81-0.83) and 0.95 (95% CI 0.91-0.95), respectively. A total of 241 (7%) AS gradings were reclassified after AnC was applied, mostly when the uncorrected mean gradient was within 5 mmHg of the severity classification cutoff. AnC can be performed with a modest inter-rater and intra-rater correlation and high degree of inter-rater and intra-rater agreement for AS severity grading. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. [The diagnostic performance of color Doppler ultrasonography for newborn four cases of midgut volvulus accompanied by intestinal malrotation].

    Science.gov (United States)

    Ikeshima, Yukari; Hisano, Katsuya; Morisawa, Takeshi; Inoue, Kozue; Shimamoto, Masahiro; Koujitani, Toshiaki; Yonetani, Masahiko; Yasufuku, Masao

    2014-03-01

    Midgut volvulus accompanied by intestinal malrotation is classified as a surgical emergency disease of the newborn, which emerges with the bilious vomiting or melena. This report presents four patients of this disease in our hospital, evaluated by color Doppler ultrasonography before surgical operation. All four patients were presented by bilious vomiting at the onset. By color Doppler ultrasonography method, the whirlpool sign which is the view of intestine and superior mesenteric vein rotated around with the axis of superior mesenteric artery, were shown in all cases. This whirlpool sign led to the diagnosis of midgut volvulus accompanied by intestinal malrotation. Intestinal contrast imaging was tested in three patients for the purpose of confirming the diagnosis. Repair of the volvulus and a ladd operation was performed in all four patients, without the excision of intestine because of no intestinal ischemic change. The clinical courses of four cases were good, and all patients were discharged within 17 days. Early diagnosis and timely surgical operation are essential for decreasing the possibility of occurring intestinal ischemic changes and improving clinical outcome after surgical operation. We propose that color Doppler ultrasonography is the powerful tool for the diagnosis of this disease, especially for the newborn, for whom the available diagnostic tests are limited.

  9. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  10. Association of maternal and umbilical cord blood leptin concentrations and abnormal color Doppler indices of umbilical artery with fetal growth restriction

    Directory of Open Access Journals (Sweden)

    Elahe Zareaan

    2017-08-01

    Full Text Available Background: Fetal growth restriction (FGR is a condition with heterogeneous pathophysiology which characterized by fetal weight less than the tenth percentile for gestational age. Several factors have impact on maternal, placental and fetal due to growth restriction. Objective: The aim of this study was to investigate the relationship between levels of leptin in the cord, and serum leptin of mothers also abnormal color Doppler indices of umbilical artery with fetal growth restriction. Materials and Methods: This is a cross sectional study conducted in Isfahan, Iran, 2015-2016. We recruited 40 women with singleton pregnancies complicated by fetal growth restriction (Group I and 40 pregnant women with normal fetal growth (Group II with matched age. Maternal serum and umbilical artery leptin levels were determined with Enzyme-Linked immunosorben method. Also, color Doppler ultrasound of umbilical artery was performed. Results: Mean maternal and fetal leptin levels were lower in the FGR group compared to the normal group (36.58±(20.99 and 7.42 ±(4.08vs. 47.32±(22.50 and 30.49±(14.50 respectively. Also, mean fetal leptin level was lower in the group with abnormal color Doppler sonographic indices compared to the normal group (7. 40 ±(4.10vs 27.06±(15.80, respectively. Conclusion: This study indicated that maternal and fetal leptin levels are correlated with FGR originating from damaged placental function; also fetal leptin level can indicate changes in color Doppler sonographic indices.

  11. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    Science.gov (United States)

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P closure (P closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  12. Cavernous hemangioma of liver: a comparative study of MRI and color Doppler ultrasound (with 58 case report)

    International Nuclear Information System (INIS)

    Luan Zhiyong; Xu Weidong; Wang Jiazhong

    2006-01-01

    Objective: To evaluate MRI and the color Doppler ultrasound in the diagnosis of cavernous hemangioma of liver. Methods: In total 58 patients with hemangioma of liver underwent dynamic enhanced MRI and the color Doppler ultrasound examination. The imaging manifestations obtained by both modalities were comparatively studied. Result: Highly echoic lesions were revealed in 36 cases out of 58; low echoic lesions were noted in 8; and in 14 cases the tumors were of mixed echoic. On T 1 WI the lesions were hypo- or slightly hypo-intense; while on T 2 WI they were hyper- or slightly hyper-intense. The nidi were hyper-intense on T 2 WI of CRE array. On enhanced scan the lesions were quickly fully enhanced in 25 cases out of 58. Peripheral nodular enhancement was seen in 19 cases, and centered spreading enhancement was demon- strated in 14 cases. On delayed scan remarkable homogenous enhancement was observed in all cases. Conclusion: The bigger size has the hemangioma, the smaller highly echoic proportion and bigger mixed echoic or poorly echoic proportion will be found within the lesions. More peripheral nodular enhancement will be revealed on enhanced MRI scan when the tumor size is getting larger, in which the proportion of quickly fully enhancement will decrease gradually. Ultrasound is better than MRI in the evaluation of the liver hemangioma smaller than 3 cm in diameter. MRI is superior to color Doppler ultrasound in diagnosing the lesion larger' than 3 cm in diameter. (authors)

  13. Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation.

    Science.gov (United States)

    Garcia, M J; Smedira, N G; Greenberg, N L; Main, M; Firstenberg, M S; Odabashian, J; Thomas, J D

    2000-01-01

    To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

  14. Experimental study on blood flow patterns through the phantoms of the intracranial arterial aneurysms using color Doppler imaging

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Jeong, Eun Kee; Rhim, Yoon Chul; Kim, Sung Bin; Lee, Dong Hoon; Kim, Dae In

    1994-01-01

    The occurrence, growth, thrombosis, and rupture of intracranial saccular aneurysms can be directly related to the effect of hemodynamic forces. We developed the phantom flow models and compared with the computer simulation program to analyse the flow pattern and hemodynamics that might be responsible for the intracranial arterial aneurysms. We designed the arterial phantoms of three major sites of intracranial arterial aneurysm ; 1) basilar artery tip, 2) internal carotid artery bifurcation, 3) curved area of internal carotid artery. Flow patterns in the aneurysmal portion of phantoms were evaluated with color Doppler system on the connection with automatic closed type of circulation system. Then, we compared the results with computer simulation. The hemodynamic characteristics of the phantoms were identical with those obtained by computerisation's. Three distinct zones of flow were identified by color Doppler studies on the aneurysm of the curved area of an internal carotid artery : 1) an inflow zone entering the aneurysm at the distal aspect of its orifice, 2) an outflow zone exiting the aneurysm at the proximal aspect of its orifice, 3) a central slow vortex.However, the phantoms of basilar artery tip and artery bifurcation showed a direct inflow stream at the dome of an aneurysm. Flow dynamics in the various phantoms of the aneurysms can be successfully evaluated with color Doppler imaging, and were consistent with those predicted by computer simulations

  15. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    Science.gov (United States)

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Discrimination between pleural thickening and minimal pleural effusion using color Doppler chest ultrasonography

    OpenAIRE

    Hasan, Ali A.; Makhlouf, Hoda A.; Mohamed, Alaa R.M.

    2013-01-01

    Background: The discrimination of pleural thickening from minimal pleural effusion may be difficult as both lesions appear as anechoic on grayscale ultrasound, hence, free of “echoes” does not confirm the presence of pleural fluid. Aim of this study: To evaluate the value of color Doppler ultrasound in differentiating minimal pleural effusion that could be aspirated from pleural thickening and to compare it with grayscale ultrasound. Patients and methods: This analytic cross-sectional s...

  17. Imaging the heart: cardiac scintigraphy and echocardiography in US hospitals (1983)

    International Nuclear Information System (INIS)

    McPhee, S.J.; Garnick, D.W.

    1986-01-01

    The rapid growth of cardiac catheterization has raised questions about the availability of less costly, noninvasive tests such as cardiac scintigraphy and echocardiography. To assess their availability and rates of use, we surveyed 3778 non-federal short-term US hospitals in June, 1983. Overall, 2605 hospitals (69%) offered 201 Tl myocardial perfusion scans, 2580 (68%) 99mTc equilibrium gated blood pool scans, and 2483 (67%) cardiac shunt scans; 1679 hospitals (44%) offered M-mode and/or 2-dimensional echocardiography, and 768 (20%) pulsed Doppler echocardiography. Volumes of procedures varied enormously among hospitals capable of performing them. High volumes of both scintigraphy and echocardiography were performed in a small number of hospitals. Larger, voluntary, and teaching hospitals performed higher volumes of both procedures. Despite widespread availability of these noninvasive technologies, high volumes of both cardiac scintigraphy and echocardiography procedures are concentrated in a small number of US hospitals

  18. Evaluation of postoperative pulmonary regurgitation after surgical repair of tetralogy of Fallot: comparison between Doppler echocardiography and MR velocity mapping

    Energy Technology Data Exchange (ETDEWEB)

    Grothoff, Matthias; Spors, Birgit; Gutberlet, Matthias [Charite Campus Virchow Klinikum, Department of Radiology and Nuclear Medicine, Berlin (Germany); Abdul-Khaliq, Hasim [Deutsches Herzzentrum, Department of Congenital Heart Disease/Pediatric Cardiology, Berlin (Germany)

    2008-02-15

    Pulmonary regurgitation is a common finding in patients after correction of tetralogy of Fallot (TOF). Right ventricular impairment and even ventricular arrhythmia have been ascribed to pulmonary valve insufficiency (PI), which is therefore an important issue in follow-up examinations. To compare PI measured by echocardiography (ECHO) with data provided by cardiac MRI (CMR). We studied 54 selected patients (18 female; median age 14.0 years, range 3.8-53.4 years) after surgical correction of TOF. To quantify pulmonary regurgitant fraction (PRF) by CMR, flow velocity mapping was performed. On Doppler ECHO, length, width and localization of regurgitant flow was measured. The severity of PI was categorized as mild, moderate or severe and compared to the data obtained by CMR. On CMR the mean PRF was 29.2 {+-} 13.4%. Patients with a transannular patch had a significantly higher PRF (39.9 {+-} 11.6%) than patients with an intact annular ring (23.6 {+-} 11.4%). Differentiation by Doppler ECHO between the categories mild, moderate and severe PI was confirmed by significant differences in PRF measured by CMR (mild vs. moderate P < 0.04; moderate vs. severe P < 0.014; mild vs. severe P < 0.001). Furthermore, PRF correlated with right ventricular end diastolic volume index (r = 0.45, P < 0.01) and right ventricular end systolic volume index (r = 0.39, P < 0.01). Doppler ECHO can estimate the severity of PI after repair of TOF with acceptable results compared to CMR flow measurement. In univariate analysis there is only a weak influence of PRF on right ventricular volume. (orig.)

  19. Role of modern 3D echocardiography in valvular heart disease

    Science.gov (United States)

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  20. The diagnosis value of color doppler ultrasound in evaluating small renal carcinoma

    International Nuclear Information System (INIS)

    Chen Gaiyi

    2009-01-01

    Objective: To characterize the ultrasound and color doppler imaging of small renal carcinoma. Methods: Ultrasound and color doppler images by convex-probe and high frequency-probe of 24 patients with renal carcinoma confirmed by surgery and histology were analyzed retrospectively. Tumor echo, halo, internal blood flow and peripheral tumor blood flow were observed. Results: Tumor echo in 9 lesions was hyper-echo, in 4 was iso-echoic, in 10 was hypo-echo, and in 1 was echoless. Halo was detected in 9 tumors, and small cyst was detected in 5 tumors. By using the convex-probe, peripheral and internal blood flow signal in 24 tumors were observed. Spot blood follow was detected in 6 tumors, half-circularity blood follow in 18 tumors and no circularity blood follow. Detection rate of internal blood flow was 20.83%. By using the high frequency-probe in 21 tumors, spot blood was detected in 1 tumor, half-circularity blood follow in 14 tumors, circularity blood follow in 6 tumors. Detection rate of internal blood flow was 90.48%. It was not satisfied for high frequency-probe in 3 patients because of obesity. Accordance of the diagnosis by high frequency-probe ultrasound was 90.48% and 91.67% by CT (P > 0.05). Conclusion: Detection of renal carcinoma is sensitive by ultrasound. The high frequency-probe is significant sensitive to detect blood follow in renal carcinoma and is helpful to correct diagnosis of renal carcinoma. (authors)

  1. The application of color Doppler flow imaging in the diagnosis and therapeutic effect evaluation of erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Xu-Jun Xuan

    2016-01-01

    Full Text Available We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg, prostaglandin E 1 (10 mg, and lidocaine (2%, 0.5-1 ml, the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades V to II. Then, the patients were given oral sildenafil (50-100 mg and scored according to the International Index of Erectile Function (IIEF-5 questionnaire. The number of patients with penile rigidities of Schramek Grades II to V was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P< 0.05, the peak systolic velocity (r = 0.45, P< 0.05, and penile rigidity (r = 0.75, P< 0.05, and was negatively correlated with the end diastolic velocity (r = −0.74, P< 0.05. For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction.

  2. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  3. Evaluation of postoperative pulmonary regurgitation after surgical repair of tetralogy of Fallot: comparison between Doppler echocardiography and MR velocity mapping

    International Nuclear Information System (INIS)

    Grothoff, Matthias; Spors, Birgit; Gutberlet, Matthias; Abdul-Khaliq, Hasim

    2008-01-01

    Pulmonary regurgitation is a common finding in patients after correction of tetralogy of Fallot (TOF). Right ventricular impairment and even ventricular arrhythmia have been ascribed to pulmonary valve insufficiency (PI), which is therefore an important issue in follow-up examinations. To compare PI measured by echocardiography (ECHO) with data provided by cardiac MRI (CMR). We studied 54 selected patients (18 female; median age 14.0 years, range 3.8-53.4 years) after surgical correction of TOF. To quantify pulmonary regurgitant fraction (PRF) by CMR, flow velocity mapping was performed. On Doppler ECHO, length, width and localization of regurgitant flow was measured. The severity of PI was categorized as mild, moderate or severe and compared to the data obtained by CMR. On CMR the mean PRF was 29.2 ± 13.4%. Patients with a transannular patch had a significantly higher PRF (39.9 ± 11.6%) than patients with an intact annular ring (23.6 ± 11.4%). Differentiation by Doppler ECHO between the categories mild, moderate and severe PI was confirmed by significant differences in PRF measured by CMR (mild vs. moderate P < 0.04; moderate vs. severe P < 0.014; mild vs. severe P < 0.001). Furthermore, PRF correlated with right ventricular end diastolic volume index (r = 0.45, P < 0.01) and right ventricular end systolic volume index (r = 0.39, P < 0.01). Doppler ECHO can estimate the severity of PI after repair of TOF with acceptable results compared to CMR flow measurement. In univariate analysis there is only a weak influence of PRF on right ventricular volume. (orig.)

  4. Detection of congenital heart disease by fetal echocardiography

    International Nuclear Information System (INIS)

    Fayyaz, A.; Majeed, S.M.I.

    2013-01-01

    Objective: The objective of the study was to determine the sensitivity, specificity, accuracy and predictive value of fetal echocardiography in our set up using postnatal echocardiography as gold standard. Study Design: Validation study. Place and Duration of study: This is an ongoing study in the Radiology department of CMH Rawalpindi and Armed Forces Institute of Cardiology (AFIC) Rawalpindi and the data collected from January 2007 to Jan 2012 is presented. Patients and Methods: Two hundred eighty seven patients reported for fetal echocardiography. Two hundred twenty nine patients were subsequently included in the study. These included patients of all ages who reported to the Radiology department of CMH Rawalpindi for fetal echocardiography. Fetal echo was done on Toshiba Aplio with 3.5 MHz probe having Doppler facility. Post natal evaluation was done by a pediatric cardiologist. Results: There were 207 (90.4%) true negative cases, 15 (6.6%) true positive, 2 (0.9%) false positive and 6 (2.2%) false negative cases. The sensitivity, specificity, positive and negative predictive values were 75%, 99%, 88%, 97% respectively. Conclusion: Fetal echocardiography has high specificity, negative predictive values and accuracy and cases diagnosed as normal can reassure the parents about the normal cardiac status of the fetus. (author)

  5. Transesophageal echocardiography in the assessment of coronary arteries

    International Nuclear Information System (INIS)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M.

    1993-01-01

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author)

  6. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  7. The use of echocardiography in Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Cai, Qiangjun; Shuraih, Mossaab; Nagueh, Sherif F

    2012-04-01

    Endocardial mapping and radiofrequency catheter ablation are well established modalities for the diagnosis and treatment of patients with Wolff-Parkinson-White (WPW) syndrome associated with tachyarrhythmias. However, the electrophysiologic techniques are invasive, require radiation exposure, and lack spatial resolution of cardiac structures. A variety of echocardiographic techniques have been investigated as a non-invasive alternative for accessory pathway localization. Conventional M-mode echocardiography can detect the fine premature wall motion abnormalities associated with WPW syndrome. However, it is unable to identify the exact site of accessory pathway with sufficient accuracy. 2D, 2D-guided M-mode, and 2D phase analysis techniques are limited by image quality and endocardial border definition. Various modalities of tissue Doppler echocardiography significantly increase the accuracy of left-sided accessory pathway localization to 80-90% even in patients with poor acoustic window. However, right-sided pathways remain a diagnostic challenge. Strain echocardiography by speckle tracking has recently been evaluated and appears promising. Different cardiac abnormalities have been detected by echocardiography in WPW patients. Patients with WPW syndrome and tachyarrhythmias have impaired systolic and diastolic function which improves after radiofrequency ablation. Echocardiography is useful in identifying patient with accessory pathway-associated left ventricular dyssynchrony and dysfunction who may benefit from ablation therapy. Transesophageal and intracardiac echocardiography have been used to guide ablation procedure. Ablation-related complications detected by routine echocardiography are infrequent, rarely clinically relevant, and of limited value.

  8. Effect of preload alternations on a new Doppler echocardiographic index of combined systolic and diastolic performance

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Egstrup, K

    1999-01-01

    The objective of the study was to assess the effect of preload alternations on a nongeometric Doppler index of combined systolic and diastolic myocardial performance (MPI). Doppler echocardiography was performed during Valsalva maneuver, passive leg lifting, and after sublingual administration of...

  9. Color-flow Doppler US usefulness in upper-extremity venous thrombosis

    International Nuclear Information System (INIS)

    Grassi, C.J.; Polak, J.F.

    1988-01-01

    Compared with its application in the leg veins, US has been used infrequently in the axillary-subclavian veins. Using color-flow Doppler US (CFDUS) as the primary means of follow-up, seven patients from a consecutive 120 venograms in the subgroup of effort thrombosis were restudied to compare CFDUS with venography in blinded fashion. In all seven patients, CFDUS allowed prediction of the thrombus location and the collateral veins; swirl (turbulent venous flow) was detected in two patients, asymmetric jugular distention was seen in three, and the normal response on inspiration was vein collapse, The authors experience indicates the CFDUS shows good correlation with axillary-subclavian venography, that blind areas behind the clavicle can be overcome, and that CFDUS may be preferable in follow-up to avoid patient discomfort or contrast material-induced phlebitis

  10. In-vivo imaging of blood flow dynamics using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2000-04-01

    Noninvasive quantitation of blood flow in the retinal micro circulation may elucidate the progression and treatment of ocular disorders including diabetic retinopathy, age-related degeneration, and glaucoma. Color Doppler optical coherence tomography was recently introduced as a technique allowing simultaneous micron-scale resolution cross-sectional imaging of tissue micro structure and blood flow in the human retina. Here, time-resolved imaging of dynamics of blood flow profiles was performed to measure cardiac pulsatility within retinal vessels. Retinal pulsatility has been shown to decrease throughout the progression of diabetic retinopathy.

  11. High prevalence of rheumatic heart disease detected by echocardiography in school children.

    Science.gov (United States)

    Bhaya, Maneesha; Panwar, Sadik; Beniwal, Rajesh; Panwar, Raja Babu

    2010-04-01

    It is fairly easy to detect advanced valve lesions of established rheumatic heart disease by echocardiography in the clinically identified cases of rheumatic heart disease. However, to diagnose a subclinical case of rheumatic heart disease, no uniform set of echocardiographic criteria exist. Moderate thickening of valve leaflets is considered an indicator of established rheumatic heart disease. World Health Organization criteria for diagnosing probable rheumatic heart disease are more sensitive and are based on the detection of significant regurgitation of mitral and/or aortic valves by color Doppler. We attempted diagnosing RHD in school children in Bikaner city by cardiac ultrasound. The stratified cluster sampling technique was employed to identify 31 random clusters in the coeducational schools of Bikaner city. We selected 1059 school children aged 6-15 years from these schools. An experienced operator did careful cardiac auscultation and echocardiographic study. A second expert confirmed the echocardiographic findings. The prevalence of lesions suggestive of rheumatic heart disease by echocardiography was 51 per 1,000 (denominator = 1059; 95% CI: 38-64 per 1,000). We were able to clinically diagnose RHD in one child. None of these children or their parents having echocardiographic evidence of RHD could provide a positive history of acute rheumatic fever. By echocardiographic screening, we found a high prevalence of rheumatic heart disease in the surveyed population. Clinical auscultation had much lower diagnostic efficacy.

  12. Association Between Echocardiography Laboratory Accreditation and the Quality of Imaging and Reporting for Valvular Heart Disease.

    Science.gov (United States)

    Thaden, Jeremy J; Tsang, Michael Y; Ayoub, Chadi; Padang, Ratnasari; Nkomo, Vuyisile T; Tucker, Stephen F; Cassidy, Cynthia S; Bremer, Merri; Kane, Garvan C; Pellikka, Patricia A

    2017-08-01

    It is presumed that echocardiographic laboratory accreditation leads to improved quality, but there are few data. We sought to compare the quality of echocardiographic examinations performed at accredited versus nonaccredited laboratories for the evaluation of valvular heart disease. We enrolled 335 consecutive valvular heart disease subjects who underwent echocardiography at our institution and an external accredited or nonaccredited institution within 6 months. Completeness and quality of echocardiographic reports and images were assessed by investigators blinded to the external laboratory accreditation status and echocardiographic results. Compared with nonaccredited laboratories, accredited sites more frequently reported patient sex (94% versus 78%; P heart disease. Future quality improvement initiatives should highlight the importance of high-quality color Doppler imaging and echocardiographic quantification to improve the accuracy, reproducibility, and quality of echocardiographic studies for valvular heart disease. © 2017 American Heart Association, Inc.

  13. Basal ganglia perfusion using dynamic color Doppler sonography in infants with hypoxic ischemic encephalopathy receiving therapeutic hypothermia: a pilot study.

    Science.gov (United States)

    Faingold, Ricardo; Cassia, Guilherme; Morneault, Linda; Saint-Martin, Christine; Sant'Anna, Guilherme

    2016-10-01

    The objective of this study was to evaluate the cerebral perfusion of the basal ganglia in infants with hypoxic-ischemic encephalopathy (HIE) receiving hypothermia using dynamic color Doppler sonography (CDS) and investigate for any correlation between these measurements and survival. Head ultrasound (HUS) was performed with a 9S4 MHz sector transducer in HIE infants submitted to hypothermia as part of their routine care. Measurements of cerebral perfusion intensity (CPI) with an 11LW4 MHz linear array transducer were performed to obtain static images and DICOM color Doppler videos of the blood flow in the basal ganglia area. Clinical and radiological data were evaluated retrospectively. The video images were analyzed by two radiologists using dedicated software, which allows automatic quantification of color Doppler data from a region of interest (ROI) by dynamically assessing color pixels and flow velocity during the heart cycle. CPI is expressed in cm/sec and is calculated by multiplying the mean velocity of all pixels divided by the area of the ROI. Three videos of 3 seconds each were obtained of the ROI, in the coronal plane, and used to calculate the CPI. Data are presented as mean ± SEM or median (quartiles). A total of 28 infants were included in this study: 16 male, 12 female. HUS was performed within the first 48 hours of therapeutic hypothermia treatment. CPI values were significantly higher in the seven non-survivors when compared to survivors (0.226±0.221 vs . 0.111±0.082 cm/sec; P=0.02). Increased perfusion intensity of the basal ganglia area within the first 48 of therapeutic hypothermia treatment was associated with poor outcome in neonates with HIE.

  14. Role of color Doppler US in the evaluation of uterine leiomyoma treated with gonadotrophin-releasing hormone (GnRH) agonist (Zoladex)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Sik; Sohn, Cheol Ho; Lee, Tae Sung [Keimyung University Dongsan Medical Center, Taegu (Korea, Republic of)

    1999-03-15

    To access the role of color Doppler US in the evaluation of uterine leiomyoma treated with GnRH agonist (Zoladex). Out of 25 patients with uterine leiomyoma treated with Zoladex, nineteen cases of leiomyoma in 18 women who had US examination before and after medication were included in this study. Zoladex was injected subcutaneously three times within three months. Both gray scale and color Doppler US were obtained before and 1-3 months after the medication. The size, volume, location and internal echoes of the leiomyoma were recorded with gray scale US. Changes in the amount of color signal within leiomyomas were recorded. Pulsatility index (PI), resistive index (RI), peak systolic velocity (PSV) of both uterine artery and arteries within leiomyomas were also recorded. The image findings of good response group and poor response group in which the volume reduction of the leiomyoma was above or below 50% respectively were compared with each other. The reduction of the volume of leiomyoma was compared between a group with decrease in the amount of color signals during follow-up US and a group with increase or no change. Mean reduction of the volume of leiomyomas was 52%. Changes in the amount of color signals of the leiomyoma, PI, RI, PSV obtained from the arteries within leiomyomas were not correlated with the change of the volume of leiomyomas. PSV of uterine artery in one month follow-up and PI of two month follow-up were correlated with the changes of the volume of leiomyomas (p<0.05). RI of uterine artery in two month follow-up was useful in prediction of the good response group and the poor response group (p<0.05). The prediction of the volume reduction of leiomyoma following Zoladex medication might be possible by obtaining RI of uterine artery in two month follow-up. Doppler US of the arteries within the leiomyoma was not useful.

  15. Role of color Doppler US in the evaluation of uterine leiomyoma treated with gonadotrophin-releasing hormone (GnRH) agonist (Zoladex)

    International Nuclear Information System (INIS)

    Kim, Jung Sik; Sohn, Cheol Ho; Lee, Tae Sung

    1999-01-01

    To access the role of color Doppler US in the evaluation of uterine leiomyoma treated with GnRH agonist (Zoladex). Out of 25 patients with uterine leiomyoma treated with Zoladex, nineteen cases of leiomyoma in 18 women who had US examination before and after medication were included in this study. Zoladex was injected subcutaneously three times within three months. Both gray scale and color Doppler US were obtained before and 1-3 months after the medication. The size, volume, location and internal echoes of the leiomyoma were recorded with gray scale US. Changes in the amount of color signal within leiomyomas were recorded. Pulsatility index (PI), resistive index (RI), peak systolic velocity (PSV) of both uterine artery and arteries within leiomyomas were also recorded. The image findings of good response group and poor response group in which the volume reduction of the leiomyoma was above or below 50% respectively were compared with each other. The reduction of the volume of leiomyoma was compared between a group with decrease in the amount of color signals during follow-up US and a group with increase or no change. Mean reduction of the volume of leiomyomas was 52%. Changes in the amount of color signals of the leiomyoma, PI, RI, PSV obtained from the arteries within leiomyomas were not correlated with the change of the volume of leiomyomas. PSV of uterine artery in one month follow-up and PI of two month follow-up were correlated with the changes of the volume of leiomyomas (p<0.05). RI of uterine artery in two month follow-up was useful in prediction of the good response group and the poor response group (p<0.05). The prediction of the volume reduction of leiomyoma following Zoladex medication might be possible by obtaining RI of uterine artery in two month follow-up. Doppler US of the arteries within the leiomyoma was not useful.

  16. Magnetic resonance angiography in renal grafts. Comparison with color Doppler echography

    International Nuclear Information System (INIS)

    Yanagisawa, Takayoshi; Otsubo, Osamu; Nozaki, Harushige

    1995-01-01

    We studied relationship between magnetic resonance angiography (MRA) of renal graft and renal graft function in 14 renal transplantations (10 from living donors, 4 from cadaveric donors). MRA was performed on 0.3-T permanent magnet system (MRP 7000, HITACHI, JAPAN) using 2 dimensional time of flight technique (FOV: 350 mm 2 , RT: 60 msec, ET: 10 msec, FA: 90deg, Slice: volumes 60, thickness 4 mm, overlap 1 mm). As for parameters of renal graft function, we evaluated color doppler echography (CD) of transplanted renal artery, renal blood flow (RBF), velocity of interlobar artery (ILA) and serum creatinine level (S-Cr). CD, RBF and velocity of ILA were visualized and measured by duplex color doppler echosystem (EUB-565A, HITACHI, JAPAN). Depending on visualization of transplanted renal artery, MRA was graded into 3 groups (MA Grade 3: visualization of ILA, MA Grade 2: visualization of segmental artery and the first branch but no visualization of ILA, MA Grade 1: visualization of main renal artery only). Likewise, visualization of CD was graded into 3 groups (CD Grade 3: good visualization of arcuate artery (AA) and ILA, CD Grade 2: poor visualization of AA but good visualization of ILA, CD Grade 1: poor visualization of ILA). The MRA grading had a very significant correlation (r=0.79, p<0.001) with the CD grading. As for RBF and velocity of ILA, the RBF of MA Grade 3 group (n=8) was significantly (p<0.05) higher than the MA Grade 2 group (n=4) and the MA Grade 1 group (n=2), and the velocity of ILA of MA Grade 3 group was also higher than the above groups but not significantly. Furthermore, the S-Cr of MA Grade 3 was significantly (p<0.05) lower than the others. These results showed that MRA of renal graft had a qualitative index of renal graft function. (author)

  17. Does color Doppler sonography improve the clinical assessment of patients with acute scrotum?

    International Nuclear Information System (INIS)

    Pepe, Pietro; Panella, Paolo; Pennisi, Michele; Aragona, Francesco

    2006-01-01

    Introduction and objectives: Our experience concerning the use of color Doppler sonography (CDS) in the differential diagnosis of acute scrotum is reported. Material and methods: From July 2000 to July 2005, 155 patients (median 17.2 years) were admitted with a diagnosis of acute scrotum (unilateral in 150 cases, bilateral in 5). Along with a careful anamnesis and the physical exam, all patients underwent a CDS study of the scrotal content using a sonograph GE Logiq 500 with a multifrequency (7.5-10 MHz) linear probe Small Part. The following CDS parameters were evaluated: intensity of the color-power signal on the testicular parenchyma and on the epididymis; systolic peak velocity (SPV) and telediastolic velocity (TDV) in correspondence of the gonadal hilum. Ultrasound and flowmetry parameters registered on the painful testis were compared with those registered on the healthy controlateral testis. The reduction/absence versus the increase of color-power signal in the parenchyma and the reduction/absence versus the increase of SPV and TDV in the centripetal intratesticular arteries were considered presumptive of testicular torsion versus orchiepididymitis. Results: The results only refer to the 150 patients (300 testis) with acute monolateral scrotum. The clinical picture and the physical exam suggested a torsion of the spermatic cord in 40 cases, a spontaneous de-torsion in 5, an orchiepididymitis in 80, a blunt scrotal trauma in 15, a bulky epididymal cyst or a hydrocele in 4 and a testicular pain of unknown etiology in the remaining 6 cases. Standard US was pathological in 95 patients (63.3%); CDS was pathologic in 70 patients and in 42 of them suggested a testicular torsion. Fifty-three patients underwent surgical exploration: among 42 patients with a presumptive diagnosis of testicular torsion, the diagnosis was confirmed in 22 cases, no anomaly was found in 16 cases and in 4 patients a torsion of testicular appendix was found. The rupture of the tunica

  18. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  19. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  20. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    OpenAIRE

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 ...

  1. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    Science.gov (United States)

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  2. Avaliação da anastomose de artéria torácica interna esquerda com artéria interventricular anterior pela ecodopplercardiografia Evaluation of left internal thoracic artery anastomosis with left anterior descending coronary artery by Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Adelaide Arruda

    1997-12-01

    Full Text Available OBJETIVO: Avaliar o valor do ecocardiograma Doppler(ECO transtorácico na identificação de perviabilidade da anastomose entre artéria torácica interna esquerda (ATIE e interventricular anterior, realizada pela técnica de revascularização miocárdica pela minitoracotomia sem circulação extracorpórea. MÉTODOS: Estudaram-se os primeiros 12 pacientes, consecutivos, no período de pós-operatório intra-hospitalar pelo ECO, utilizando-se transdutores de 5MHz, pela via paraesternal esquerda, preferencialmente. Foram analisadas velocidades máximas e integrais de velocidade dos componentes sistólico e diastólico das curvas espectrais de fluxo Doppler. Todos pacientes foram submetidos à cinecoronariografia, enquanto hospitalizados. RESULTADOS: O ECO foi exeqüível em 93% dos pacientes. Nos com anastomose pérvia (6/7, observou-se ao estudo Doppler amplo componente diastólico (padrão A. Naqueles com anastomose obstruída (4/4 o padrão observado foi de predomínio sistólico (padrão B (p=0,003*. CONCLUSÃO: O ECO da ATIE anastomosada com a artéria interventricular anterior, após cirurgia de revascularização miocárdica pela técnica de minitoracotomia, permitiu caracterizar precocemente, com precisão, a perviabilidade da anastomose.PURPOSE: To study the value of Doppler echocardiography as a tool for the evaluation of left internal thoracic artery graft (LITAG patency in patients who underwent coronary revascularization using minimally invasive bypass surgery without extracorporeal circulation. METHODS: The first 12 consecutive patients were studied after coronary artery bypass surgery using a 5MHz Doppler transducer. Doppler signals for the systolic and diastolic flow velocities were preferably obtained in the second intercostal space. All patients underwent coronary angiography while hospitalized. RESULTS: The exam was feasible in 93% of patients. Doppler flow pattern was predominantly diastolic (pattern A in patients with patent

  3. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  4. Echocardiography Practice: Insights into Appropriate Clinical Use, Technical Competence and Quality Improvement Program

    Science.gov (United States)

    Kossaify, Antoine; Grollier, Gilles

    2014-01-01

    Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342

  5. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  6. Tumor vascularity evaluated by transrectal color Doppler US in predicting therapy outcome for low-lying rectal cancer

    International Nuclear Information System (INIS)

    Barbaro, Brunella; Valentini, Vincenzo; Coco, Claudio; Mancini, Anna Paola; Gambacorta, Maria Antonietta; Vecchio, Fabio Maria; Bonomo, Lorenzo

    2005-01-01

    Purpose: To evaluate the impact on T downstaging of the vasculature supplying blood flow to rectal cancer evaluated by color Doppler ultrasound. Methods and Materials: Color Doppler images were graded in 29 T3-staged rectal carcinoma patients sonographically just before chemoradiation. Any arterial vessels detected in rectal masses were assigned one of two grades: vascularity was considered as grade 1 for vessels feeding the periphery and as grade 2 for vessels coursing in all rectal masses within its peripheral and central portions. The pulsatility indices (PI = peak systolic velocity - end-diastolic velocity/time-averaged maximum velocity) were calculated in the central and peripheral portions. Results: The pathologic observations showed a change in stage in 15 of the 23 patients graded 2, positive predictive value 65.2% (p = 0.047), and in one of the six rectal cancers graded 1 (negative predictive value, 83.3%). The minimal peripheral PI values in rectal cancer graded 2 were higher in nonresponding (2.2 ± 1.3) than in responding lesions (1.6 ± 0.7) p = 0.01. Conclusion: Vascularity graded 2 associated with low peripheral PI values are indicators of therapy outcome. Vascularity graded 1 and high peripheral PI values in graded 2 have negative predictive value

  7. Gender-related asymmetric brain vasomotor response to color stimulation: a functional transcranial Doppler spectroscopy study.

    Science.gov (United States)

    Njemanze, Philip C

    2010-11-30

    The present study was designed to examine the effects of color stimulation on cerebral blood mean flow velocity (MFV) in men and women. The study included 16 (8 men and 8 women) right-handed healthy subjects. The MFV was recorded simultaneously in both right and left middle cerebral arteries in Dark and white Light conditions, and during color (Blue, Yellow and Red) stimulations, and was analyzed using functional transcranial Doppler spectroscopy (fTCDS) technique. Color processing occurred within cortico-subcortical circuits. In men, wavelength-differencing of Yellow/Blue pairs occurred within the right hemisphere by processes of cortical long-term depression (CLTD) and subcortical long-term potentiation (SLTP). Conversely, in women, frequency-differencing of Blue/Yellow pairs occurred within the left hemisphere by processes of cortical long-term potentiation (CLTP) and subcortical long-term depression (SLTD). In both genders, there was luminance effect in the left hemisphere, while in men it was along an axis opposite (orthogonal) to that of chromatic effect, in women, it was parallel. Gender-related differences in color processing demonstrated a right hemisphere cognitive style for wavelength-differencing in men, and a left hemisphere cognitive style for frequency-differencing in women. There are potential applications of fTCDS technique, for stroke rehabilitation and monitoring of drug effects.

  8. Role of echocardiography in the evaluation of syncope: a prospective study

    Science.gov (United States)

    Sarasin, F P; Junod, A-F; Carballo, D; Slama, S; Unger, P-F; Louis-Simonet, M

    2002-01-01

    Objective: To study the role of echocardiography in the stepwise evaluation of syncope. Design: A prospective observational study with an 18 month follow up. Setting: University teaching hospital providing primary and tertiary care. Subjects: 650 consecutive patients with syncope and clinical suspicion of an obstructive valvar lesion, or with syncope not explained by history, physical examination, or a 12 lead ECG, who underwent bidimensional Doppler transthoracic echocardiography. Main outcome measures: The causes of syncope were assigned using published diagnostic criteria. Echocardiography was considered diagnostic when confirming a suspected diagnosis, or when revealing occult cardiac disease explaining the syncope. Results: A systolic murmur was identified in 61 of the 650 patients (9%). Severe aortic stenosis was suspected in 20 of these and was confirmed by echocardiography in eight. Follow up excluded further cases of aortic stenosis. In patients with unexplained syncope (n = 155), routine echocardiography showed no abnormalities that established the cause of the syncope. Echocardiography was normal or non-relevant in all patients with a negative cardiac history and a normal ECG (n = 67). In patients with a positive cardiac history or an abnormal ECG (n = 88), echocardiography showed systolic dysfunction (left ventricular ejection fraction ≤ 40%) in 24 (27%) and minor non-relevant findings in the remaining 64. Arrhythmias were diagnosed in 12 of the 24 patients with systolic dysfunction (50%), and in 12 of the 64 remaining patients (19%) (p < 0.01). Conclusions: Echocardiography was most useful for assessing the severity of the underlying cardiac disease and for risk stratification in patients with unexplained syncope but with a positive cardiac history or an abnormal ECG. PMID:12231593

  9. Assessment of the fetomaternal circulation in threatened abortion by transvaginal color Doppler.

    Science.gov (United States)

    Kurjak, A; Zudenigo, D; Predanic, M; Kupesic, S; Funduk, B

    1994-01-01

    Transvaginal color Doppler was used to investigate blood flow in the fetomaternal circulation of 60 women with threatened abortion and 90 women with normal intrauterine pregnancy. The obtained Doppler sonograms were analyzed and the resistance index (RI) was calculated in the maternal circulation, while in the fetal circulation the pulsatility index (PI) was used. There was no significant difference in the RI values of the maternal circulation between women with normal pregnancies and pregnancies complicated by bleeding, but with normal pregnancy outcome (p > 0.05). No differences in RI values of the uterine, arcuate and radial arteries were found between pregnancies with threatened abortion and normal pregnancy outcome and women with abnormal outcome (p > 0.05). In 9 of 21 women with visible retrochorionic hematoma, the RI of the spiral arteries was higher on the hematoma side in comparison to the opposite side (p abortion, the RI of the spiral arteries was lower in comparison to the control group. Such findings could be caused by the vasodilatating products of inflammation which probably exist in such areas. There was no significant difference in terms of the PI of fetal blood vessels between normal pregnancy and threatened abortions with normal outcome, as well as between threatened abortions with normal outcome and subsequent abortions of live fetuses (p > 0.05).

  10. Prognostic value of clinical and Doppler echocardiographic findings in children and adolescents with significant rheumatic valvular disease

    International Nuclear Information System (INIS)

    Araújo, Fátima Derlene da Rocha; Goulart, Eugênio Marcos Andrade; Meira, Zilda Maria Alves

    2012-01-01

    The diagnosis of acute rheumatic fever (RF) is based on clinical findings. However, during the chronic phase of the disease, the clinical approach is not sufficient for the follow-up of the patients and the Doppler echocardiography is a tool for the diagnosis of cardiac involvement. Prognostic variables that influence long-term outcomes are not well known. 462 patients with RF according to Jones criteria were studied, and followed-up from the initial attack to 13.6 ± 4.6 years. All patients underwent clinical assessment and Doppler echocardiography for the detection of heart valve involvement in the acute and chronic phases. Multivariate logistic regression analysis was used to identify the factors influencing long-term heart valve disease. Carditis occurred in 55.8% and subclinical valvulitis in 35.3% patients. In the chronic phase, 33% of the patients had significant valvular heart disease. No normal Doppler echocardiography exam was observed on patients who had severe valvulitis, although heart auscultation had become normal in 13% of these. In the multivariate analysis, only the severity of carditis and the mitral and/or aortic valvulitis were associated with significant valvular heart disease. Chorea or arthritis were protective factors for significant valvular heart disease, odds ratio 0.41 (95% C.I. 0.22 – 0.77) and 0.43 (95% C.I. 0.23 – 0.82), respectively. Our study suggests that the use of Doppler echocardiography during RF helps to identify prognostic factors regarding the development of significant valvular heart disease. Initial severe carditis is an important factor in the long-term prognosis of chronic RHD, whereas arthritis and chore during the initial episode of RF appears to be protective. Strict secondary prophylaxis should be mandatory in high risk patients

  11. Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography

    International Nuclear Information System (INIS)

    Clevert, D.A.; Johnson, T.; Flach, P.M.; Strautz, T.I.; Becker, C.; Reiser, M.; Jung, E.M.; Ritter, G.; Gallegos, M.T.; Kubale, R.

    2007-01-01

    The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes. (orig.)

  12. Ultrasound and Doppler examination capabilities in adult portal hypertension type definition

    Directory of Open Access Journals (Sweden)

    N. V. Tumanskaya

    2015-08-01

    Full Text Available Early portal hypertension type diagnostics is an ultimate factor concerning kind and tactics of treatment. Aim. To objectify ultrasound examination capabilities, portal hemodynamics were studied in 97 patients using impulse and color doppler. Methods and results. It was ascertained that impulse and color doppler examination allows to visualize portal vein and its branches’ structural abnormalities, define subhepatic and intrahepatic types of portal hypertension, find thrombosis and characterize its stages. In cirrhosis patients with portal hypertension, homogenous doppler signal was received from the portal vessels lumen, while signs of intraluminar pathology were seen in the case of thrombosis of portal vein. Conclusion. This means that ultrasound examination of portal vein and its branches with impulse and color doppler is informative, non invasive method, which helps to define stages of portal hypertension. Doppler ultrasonography doesn’t have negative effect of ionizing radiation and can be used for the repeated research in the dynamics of disease.

  13. Mitral valve coaptation and its relationship to late diastolic flow: A color Doppler and vector flow map echocardiographic study in normal subjects.

    Science.gov (United States)

    Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard

    2017-04-01

    Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.

  14. “Focal thyroid inferno” on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    International Nuclear Information System (INIS)

    Fu, Xianshui; Guo, Limei; Zhang, Huabin; Ran, Weiqiang; Fu, Peng; Li, Zhiqiang; Chen, Wen; Jiang, Ling; Wang, Jinrui; Jia, Jianwen

    2012-01-01

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The χ 2 test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using “focal thyroid inferno” as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of “focal thyroid inferno” is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  15. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta

    OpenAIRE

    Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara

    2015-01-01

    Background: The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. Materials and Methods: In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental m...

  16. Associations between abnormal ultrasound color Doppler measures and tendon pain symptoms in badminton players during a season: a prospective cohort study.

    Science.gov (United States)

    Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren; Christensen, Robin; Boesen, Lars; Hölmich, Per; Nielsen, Michael Bachmann; Koenig, Merete Juhl; Hartkopp, Andreas; Ellegaard, Karen; Bliddal, Henning; Langberg, Henning

    2012-03-01

    Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear. Intratendinous flow is present and associated with pain in badminton players, and intratendinous flow and pain increase during a badminton season. Cohort study (prognosis); Level of evidence, 2. Ninety-five semiprofessional badminton players were included in the study at a tournament at the start of the badminton season. All players were interviewed regarding pain. The anterior knee tendons and Achilles tendons were studied. Each tendon was scored using a quantitative grading system (grades 0-5) and a qualitative scoring system (color fraction) using color Doppler ultrasound. Eight months later, 86 of the players (91%) were retested by the same investigators during an equivalent badminton tournament (including 1032 tendon regions; 86 players with 4 tendons each with 3 regions), thus forming the study group. At the start of the season, 24 players (28%) experienced pain in 37 tendons (11%), and at the end of the season, 31 players (36%) experienced pain in 51 tendons (15%), which was a statistically significant increase (P = .0002). Abnormal flow was found in 230 tendon regions in 71 players (83%) at the start of the season compared with 78 tendon regions in 41 players (48%) at the follow-up. The decrease in abnormal flow was statistically significant (P < .0001). Of the 37 painful tendons at the start of the season, 25 had abnormal flow (68%). In contrast, 131 tendons (85%) with abnormal flow at the start of the season were pain free. At the end of the season, 18 of the 51 painful tendons (35%) had abnormal flow. Ninety-six of the 131 pain-free tendons (73%) with abnormal flow at the start of the season were normalized (no pain and normal flow) at the end of the season. It was not possible to verify any association between intratendinous flow and pain at the start of the season or at

  17. The Myocardial Performance Index During Low Dose Dobutamine Echocardiography in Normals and Patients With a Recent Myocardial Infarction

    DEFF Research Database (Denmark)

    Nørager, Betina; Husic, Mirza; Møller, Jacob E

    2004-01-01

    BACKGROUND: Wall-motion analysis during low-dose dobutamine echocardiography (LDDE) is a semiquantitative measure of left ventricular contractile reserve after myocardial infarction (MI). The Doppler echocardiographic myocardial performance index (MPI) is a quantitative measure of combined left...

  18. Identificação pelo eco-Doppler colorido de fístula arteriovenosa na trombose venosa profunda Arteriovenous fistula in deep venous thrombosis identified by color-flow Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Fanilda Souto Barros

    2006-09-01

    Full Text Available Os três casos são referentes a pacientes em tratamento para trombose venosa profunda encaminhados ao laboratório vascular para avaliação da recanalização e/ou progressão do processo trombótico. Durante o estudo pelo eco-Doppler colorido, foram identificados sinais ecográficos compatíveis com fístula arteriovenosa no interior do trombo e adjacente à parede venosa.We report on a case series of three patients undergoing treatment for deep venous thrombosis, referred to our vascular laboratory for evaluation of recanalization and/or progression of the thrombotic process. During the color-flow Doppler ultrasonography, we identified ultrasound signs typical of arteriovenous fistula flow pattern within the thrombus and adjacent to the venous wall.

  19. Endoscopic Color Doppler Ultrasonographic Evaluation of GastricVarices Secondary to Left-Sided Portal Hypertension

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Kimura, Mutsuumi; Toyota, Jouji; Karino, Yoshiyasu

    2014-01-01

    Gastric varices that arise secondary to the splenic vein occlusion can result in gastrointestinal hemorrhaging. Endoscopic color Doppler ultrasonography (ECDUS) was performed in 16 patients with gastric varices secondary to splenic vein occlusion. This study retrospectively evaluated the role of ECDUS in the diagnosis of gastric varices secondary to splenic vein occlusion. Thirteen patients had co-existing pancreatic diseases: 8 with chronic pancreatitis, 4 with cancer of the pancreatic body or tail and 1 with severe acute pancreatitis. Of the remaining 3 patients, 1 had myeloproliferative disease, 1 had advanced gastric cancer, and the third had splenic vein occlusion due to an obscure cause. The endoscopic findings of gastric varices were: variceal form (F) classified as enlarged tortuous (F2) in 12 cases and large, coil-shaped (F3) in 4 cases, and positive for erosion or red color sign of the variceal surface in 4 cases and negative in 12 cases. ECDUS color flow images of gastric variceal flow clearly depicted a round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body in all 16 cases. The velocities of F3 type gastric varices were significantly higher than those of the F2 type. The wall thickness of varices positive for erosion or red color sign was significantly less than the negative cases. I conclude that ECDUS color flow images of gastric variceal flow depicted specific findings of gastric varices secondary to splenic vein occlusion at the round fundal region at the center, with varices expanding to the curvatura ventriculi major of the gastric body. PMID:26852679

  20. Limb Prosthetics

    Science.gov (United States)

    ... Not Show It (News) Intense Workouts May Boost Memory (News) Arthritis No Longer Just a Disease of the Old (Video) Color Doppler Echocardiography (Video) Computed Tomography (CT) Scan Additional ...

  1. Evaluation the index of ophthalmic arteries in diabetic patients with retinopathy compared to diabetic patients without retinopathy using color Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Mohammad Ghasem Hanafi

    2016-12-01

    Full Text Available Diabetic retinopathy is the most common eye complication in diabetic patients that early detection of this complication is essential. The aim of this study was to evaluate ophthalmic artery index in diabetic retinopathy by Doppler ultrasound. . In this cross-sectional study, 64 patients were studied in 4 groups (healthy, diabetic without retinopathy, background retinopathy and proliferative retinopathy. Resistance index (RI and Pulsatile Index (PI were assessed by color Doppler ultrasound. The obtained data were analyzed by ANOVA and chi-square test and ROC curve. RI in diabetic patients with proliferative retinopathy has the highest mean (0.83 and the lowest mean was observed in healthy subjects (0.54 (P <0.001 as well as in PI, the highest rate was in diabetic patients with proliferative retinopathy (1.41 and the lowest was in healthy subjects (0.92 (P <0.001. The results of our study showed that the sensitivity, specificity, positive and negative predictive values and overall accuracy of RI and PI in diabetic patients with proliferative retinopathy in the best cut-off points (0.645 and 1.0175 respectively were 100%.Ophthalmic artery index RI and PI was significantly increased in patients with diabetic retinopathy and the sensitivity and specificity for detection retinopathy was 100%. Color Doppler ultrasound method is more efficient for screening diabetic patients with retinopathy.

  2. Color Doppler imaging of the retrobulbar circulation in progressive glaucoma optic neuropathy.

    Science.gov (United States)

    Magureanu, Marineta; Stanila, Adriana; Bunescu, Liviu Valentin; Armeanu, Cristina

    2016-01-01

    It is known that elevated intraocular pressure (IOP) is the primary risk factor for glaucoma. Recently, more and more evidences have shown that the vascular deficit also plays an important role in the pathogenesis and progressions of glaucomatous optic neuropathy. This issue is backed up by glaucomatous optic neuropathy (GON) cases drug compensated in which the progression of the disease in one or both eyes is ascertained despite a normal and relatively constant IOP. The present study evaluated the hemodynamic parameters in the retrobulbar circulation in patients with progressive glaucomatous optic neuropathy in one eye, who received compensated medication. The hemodynamic parameters (PSV, EDV, IR) were measured by using color Doppler ultrasound and progression was evaluated by a repeated automated perimetry. The obtained values were statistically analyzed and compared with those obtained for the stable eye.

  3. Advanced quantitative echocardiography in arrhythmogenic right ventricular cardiomyopathy

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Hastrup Svendsen, Jesper; Sogaard, Peter

    2007-01-01

    BACKGROUND: Arrhythmogenic right ventricular (RV) cardiomyopathy (ARVC) is a regional disease of the RV myocardium with variable degrees of left ventricular involvement. Three-dimensional echocardiography and Doppler tissue imaging (DTI) are new echocardiographic modalities for the evaluation......, patients with ARVC had a decreased RV ejection fraction (0.47 +/- 0.08 vs 0.53 +/- 0.05, P vs 15.1 +/- 3.7 cm/s, P left ventricle (7.0 +/- 2.6 vs 9.5 +/- 1.9 cm/s, P ... of the longitudinal motility appears to be a sensitive marker of preclinical left ventricular involvement....

  4. Hand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography

    Directory of Open Access Journals (Sweden)

    Ramires Jose F

    2004-11-01

    Full Text Available Abstract Background Hand-carried ultrasound (HCU devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE, in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58. There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85, aortic regurgitation (kappa = 0.89, and tricuspid regurgitation (Kappa = 0.74. A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.

  5. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  6. Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: new insight into the mechanism of atrioventricular valve closure.

    Science.gov (United States)

    Schnittger, I; Appleton, C P; Hatle, L K; Popp, R L

    1988-01-01

    The purpose of this study was to prospectively determine the incidence of diastolic mitral and tricuspid regurgitation in atrioventricular (AV) block using Doppler echocardiography. The temporal relation between mitral and tricuspid diastolic insufficiency and the diastolic murmur recorded in patients with complete heart block was also investigated. Twenty-two consecutive patients with AV block (referred to the Echo-Doppler laboratory for routine clinical studies), aged 18 to 87 years, were enrolled in the study. Eleven patients had third degree AV block and a ventricular-inhibited (VVI) pacemaker, two patients had second degree AV block, seven patients had first degree AV block, one patient had blocked premature atrial complexes and one patient had atrial flutter with 4:1 AV block. Diastolic mitral regurgitation was detected in 20 patients, and diastolic tricuspid regurgitation in 21. A mid-diastolic murmur was detected in all patients except in the three youngest. The murmur occurred before diastolic regurgitation and coincided with peak forward flow through the AV valve after atrial contraction. M-mode mitral valve echocardiograms obtained in nine patients demonstrated near closure of some portions of the mitral valve after atrial contraction. Effective closure of the valve, however, did not occur unless ventricular systole supervened. In conclusion, diastolic mitral and tricuspid regurgitation are almost universally present in patients with AV block and are associated with a diastolic murmur. The murmur coincides with forward AV valve flow. Diastolic regurgitation is silent. Effective AV valve closure is not established until ventricular systole occurs, as demonstrated by M-mode echocardiographic recording of the mitral valve.

  7. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  8. Color Doppler US of normal cerebral venous sinuses in neonates: a comparison with MR venography

    International Nuclear Information System (INIS)

    Miller, Elka; Daneman, Alan; Doria, Andrea S.; Blaser, Susan; Traubici, Jeffrey; Jarrin, Jose; Shroff, Manohar; Moineddin, Rahim; Moore, Aideen

    2012-01-01

    Color Doppler US (CDUS) has been used for evaluation of cerebral venous sinuses in neonates. However, there is very limited information available regarding the appearance of superficial and deep normal cerebral venous sinuses using CDUS and the specificity of the technique to rule out disease. To determine the specificity, inter-modality and inter-reader agreement of color Doppler US (CDUS). To evaluate normal cerebral venous sinuses in neonates in comparison to MR venography (MRV). Newborns undergoing a clinically indicated brain MRI were prospectively evaluated. All underwent a dedicated CDUS of the cerebral venous sinuses within 10 h (mean, 3.5 h, range, and 2-7.6 h) of the MRI study using a standard protocol. Fifty consecutive neonates participated in the study (30 males [60%]; 25-41 weeks old; mean, 37 weeks). The mean time interval between the date of birth and the CDUS study was 19.1 days. No cases showed evidence of thrombosis. Overall agreement for US reading was 97% (range, 82-100%), for MRV reading, 99% (range, 96-100%) and for intermodality, 100% (range, 96-100%). Excellent US-MRI agreement was noted for superior sagittal sinus, cerebral veins, straight sinus, torcular Herophili, sigmoid sinus, superior jugular veins (94-98%) and transverse sinuses (82-86%). In 10 cases (20%), MRV showed flow gaps whereas normal flow was demonstrated with US. Visualization of the inferior sagittal sinus was limited with both imaging techniques. Excellent reading agreement was noted for US, MRV and intermodality. CDUS is highly specific to rule out cerebral venous thrombosis in neonates and holds potential for clinical application as part of clinical-laboratory-imaging algorithms of pre/post-test probabilities of disease. (orig.)

  9. The usefulness of contrast during exercise echocardiography for the assessment of systolic pulmonary pressure

    Directory of Open Access Journals (Sweden)

    Cordeiro Ana

    2008-10-01

    Full Text Available Abstract Background The systolic pulmonary artery pressure (PAPs can be accurately estimated, non-invasively, using continuous-wave Doppler (CWD ultrasound measurement of the peak velocity of a tricuspid regurgitant (TR jet. However, it is often difficult to obtain adequate tricuspid regurgitation signals for measurement of PAPs, what could lead to its underestimation. Therefore, utilization of air-blood-saline contrast has been implemented for the improvement of Doppler signal in several clinical contexts. It is now recommended in the evaluation of patients with pulmonary hypertension. Physical activity is severely restricted in patients with PAH, being exertional dypnea the most typical symptom. Exercise stress echo-Doppler imaging allows assessment of the response to exercise. It is an excellent screening test for patients with suspected PAH. Our purpose was to evaluate the value and accuracy of agitated saline with blood contrast echocardiography, in the improvement of the Doppler signal, to quantify PAPs during treadmill exercise-echocardiography. Purpose To evaluate the value of contrast echocardiography, using agitated saline with blood, in the improvement of the Doppler signal used to quantify the pulmonary artery systolic pressure during exercise. Methods From a total of 41 patients (pts, we studied 38 pts (93%, 35 women, aged 54 ± 12 years-old. 27 with the diagnosis of systemic sclerosis, 10 with history of pulmonary embolism and one patient with a suspected idiopathic PAH, who were referred to the Unity of Heart Failure and Pulmonary Hypertension for screening of PAH. According to the Unity protocol, a transthoracic echocardiogram was made, in left decubitus (LD, with evaluation of right ventricle-right atria gradient (RV/RAg. A peripheral venous access was obtained, with a 3-way stopcock and the patients were placed in orthostatism (O, with a new evaluation of RV/RAg. Exercise echocardiography (EE was begun, with evaluation of RV

  10. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  11. Assessment of left ventricular regional function in affected and carrier dogs with duchenne muscular dystrophy using speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Yugeta Naoko

    2011-05-01

    Full Text Available Abstract Background Two-dimensional speckle tracking echocardiography (STE is a relatively new method to detect regional myocardial dysfunction. To assess left ventricular (LV regional myocardial dysfunction using STE in Duchenne muscular dystrophy model dogs (CXMDJ without overt clinical signs of heart failure. Methods Six affected dogs, 8 carrier dogs with CXMDJ, and 8 control dogs were used. Conventional echocardiography, systolic and diastolic function by Doppler echocardiography, tissue Doppler imaging (TDI, and strain indices using STE, were assessed and compared among the 3 groups. Results Significant differences were seen in body weight, transmitral E wave and E' wave derived from TDI among the 3 groups. Although no significant difference was observed in any global strain indices, in segmental analysis, the peak radial strain rate during early diastole in posterior segment at chordae the tendineae level showed significant differences among the 3 groups. Conclusions The myocardial strain rate by STE served to detect the impaired cardiac diastolic function in CXMDJ without any obvious LV dilation or clinical signs. The radial strain rate may be a useful parameter to detect early myocardial impairment in CXMDJ.

  12. [Ultrasound and color Doppler applications in nephrology. The normal kidney: anatomy, vessels and congenital anomalies].

    Science.gov (United States)

    Meola, Mario; Petrucci, Ilaria; Giovannini, Lisa; Samoni, Sara; Dellafiore, Carolina

    2012-01-01

    Gray-scale ultrasound is the diagnostic technique of choice in patients with suspected or known renal disease. Knowledge of the normal and abnormal sonographic morphology of the kidney and urinary tract is essential for a successful diagnosis. Conventional sonography must always be complemented by Doppler sampling of the principal arterial and venous vessels. B-mode scanning is performed with the patient in supine, prone or side position. The kidney can be imaged by the anterior, lateral or posterior approach using coronal, transverse and oblique scanning planes. Morphological parameters that must be evaluated are the coronal diameter, the parenchymal thickness and echogenicity, the structure and state of the urinary tract, and the presence of congenital anomalies that may mimic a pseudomass. The main renal artery and the hilar-intraparenchymal branches of the arterial and venous vessels should be accurately evaluated using color Doppler. Measurement of intraparenchymal resistance indices (IP, IR) provides an indirect and quantitative parameter of the stiffness and eutrophic or dystrophic remodeling of the intrarenal microvasculature. These parameters differ depending on age, diabetic and hypertensive disease, chronic renal glomerular disease, and interstitial, vascular and obstructive nephropathy.

  13. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis [Department of Radiology, Medical School, University of Ioannina, 45110, Ioannina (Greece); Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani [Neonatology Clinic, Medical School, University of Ioannina, 45110, Ioannina (Greece); Vartholomatos, Georgios A. [Department of Haematology, Medical School, University of Ioannina, 45110, Ioannina (Greece)

    2003-08-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  14. Renal venous thrombosis in an infant with predisposing thrombotic factors: color Doppler ultrasound and MR evaluation

    International Nuclear Information System (INIS)

    Argyropoulou, Maria I.; Papadopoulou, Frederica; Nikolopoulos, Pangiotis; Giapros, Vassilios I.; Drougia, Aikaterini A.; Andronikou, Styliani; Vartholomatos, Georgios A.

    2003-01-01

    We report a case of a neonate with hereditary thrombophilia presenting with renal venous thrombosis (RVT). Early color Doppler findings of RVT were lacking venous flow, and the arterial diastolic flow was reversed. This very high-resistance arterial flow is for the first time described in neonatal RVT. Magnetic resonance imaging showed low signal intensity of the renal pyramids on T1- and T2-weighted images, suggesting acute hemorrhage. After intravenous contrast injection, persistent cortical enhancement was observed along with lack of medullary enhancement. Despite the progressive reestablishment of some venous drainage, the kidney showed atrophy and loss of function. (orig.)

  15. Absence of Doppler signal in transcranial color-coded ultrasonography may be confirmatory for brain death: A case report

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-08-01

    Full Text Available Transcranial Doppler ultrasonography (TCD is a valuable tool for demonstrating cerebral circulatory arrest (CCA in the setting of brain death. Complete reversal of diastolic flow (to-and-fro flow and systolic spikes in bilateral terminal internal carotid arteries and vertebrobasilar circulation are considered as specific sonogram configurations supporting the diagnosis of CCA. Because of the possibility of sonic bone window impermeability, absence of any waveform in TCD is not confirmatory for CCA unless there is documentation of disappearance of a previously well detected signal by the same recording settings. Transcranial color-coded sonography (TCCS with B-mode imaging can reliably detect adequacy of bone windows with clarity contralateral skull and ipsilateral planum temporale visualization. Therefore, absence of detectable intracranial Doppler signal along with available ultrasound window in TCCS can confirm clinical diagnosis of brain death. We herein discuss this entity from the frame of a representative case.

  16. Diagnostic accuracy of color Doppler flow imaging and Duplex US in peripheral arterial disease

    International Nuclear Information System (INIS)

    Karmel, M.I.; Polak, J.F.; Whittemore, A.D.; Mannick, J.A.; Donaldson, M.C.; O'Leary, D.H.

    1988-01-01

    Color Doppler flow imaging (5 MHz) and Duplex US were used in a prospective examination of 154 arterial segments in the lower extremities of 11 symptomatic patients. Each extremity was divided into seven arterial segments (common femoral, profunda femoral, proximal, middle, and distal superficial femoral, and proximal and distal popliteal arteries). Arterial maps were drawn for each patient and compared with the arteriograms. Seventeen significant stenoses and 18 complete occlusions were predicted and confirmed by means of arteriography. Four significant stenoses and four occlusions were predicted and not confirmed. One hundred nine normal arterial segments were correctly predicted. No significant stenoses or occlusions were missed. Prospective identification of the severity and location of disease can help to optimize both the angiographic approach and hospital services utilization

  17. Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major.

    Science.gov (United States)

    Saravi, Mehrdad; Tamadoni, Ahmad; Jalalian, Rozita; Mahmoodi-Nesheli, Hassan; Hojati, Mosatafa; Ramezani, Saeed

    2013-01-01

    Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard non-invasive diagnostic test. A total of 100 TM patients with the mean age of 19±7 years and 100 healthy controls 18.8±7 years were evaluated. Conventional echocardiography, TDI, and cardiac MRI T2* were performed in all subjects. TDI measures included myocardial systolic (Sm), early (Em) and late (Am) diastolic velocities at basal and middle segments of septal and lateral LV wall. The TM patients were also subgrouped according to those with iron load (T2* ≤ 20 ms) and those without (T2* > 20 ms), and also severe (T2* ≤ 10 ms) versus the non-severe (T2* ≤ 10 ms). Using T2* cardiovascular MR, abnormal myocardial iron load (T2* ≤ 20 ms) was detected in 84% of the patients and among these, 50% (42/84) had severe (T2* ≤ 10 ms) iron load. The mean T2* was 11.6±8.6 ms (5-36.7). A negative linear correlation existed between transfusion period of patients and T2* levels (r = -0.53, p=0.02). The following TDI measures were lower in patients than in controls: basal septal Am (p<0.05), mid-septal Em and Am (p<0.05), basal lateral Am (p<0.05), mid-lateral LV wall Sm (p<0.05) and Am (p<0.05). Tissue doppler imaging is helpful in predicting the presence of myocardial iron load in Thalassemia patients. Therefore, it can be used for screening of thalassemia major patients.

  18. Granulomatous Prostatitis: Gray-scale Transrectal Ultrasonography and Color Doppler Ultrasonography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae; Kim, Eui Jong [Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    We report here three cases of granulomatous prostatitis. All cases were confirmed by a transrectal ultrasonography (TRUS)-guided core biopsy of the prostate. Two cases received intravesical BCG therapy for a bladder tumor, and one case had no known predisposing condition. Gray-scale TRUS showed low echoic nodules in the outer gland in all cases. Color Doppler ultrasonography (CDUS) showed several dot-like blood flows within the low echoic nodules in two cases and several dot-like blood flows and short linear blood flows within the low echoic nodules in one case. Gray-scale TRUS findings of granulomatous prostatitis are similar to findings of prostate cancer. On CDUS, several dot-like blood flows or short linear blood flows were noted within the low echoic nodules in patients with granulomatous prostatitis. If low echoic nodules with dot-like or short linear blood flows are noted in patients with genitourinary tract tuberculosis or previous BCG therapy, granulomatous prostatitis should be included in the differential diagnosis. However, a prostatic biopsy is required for a final diagnosis

  19. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo; Kim, Jung Sik

    2002-01-01

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  20. The Doppler echocardiographic myocardial performance index predicts left-ventricular dilation and cardiac death after myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To investigate the value of the Doppler-derived myocardial performance index to predict early left-ventricular (LV) dilation and cardiac death after a first acute myocardial infarction (AMI), Doppler echocardiography was performed within 24 h of hospital admission, on day 5, 1 and 3 months after...... AMI in 125 consecutive patients. The index measured on day 1 correlated well with the change in end-diastolic volume index observed from day 1 to 3 months following AMI (r = 0.66, p 0.0001). One-year survival in patients with Doppler index index > or = 0......, we conclude that the Doppler echocardiographic myocardial performance index is a predictor of LV dilation and cardiac death after a first AMI....

  1. [Elective lymph node dissection in malignant melanoma--status of color Doppler findings].

    Science.gov (United States)

    Omlor, G; Dill-Müller, D; Gross, G; Kautz, G; Schüder, G; Zaun, H; Feifel, G

    1996-01-01

    Since there is still a controversial discussion about the ELND in melanoma patients, the purpose of this prospective study was to optimize the indication concerning ELND by ultrasound examinations. 144 patients with primary melanomas were checked every 3 months after excision. Echomorphologic pattern and intranodal vascularisation in the color-flow Doppler modus provide essential information for differential diagnosis. We found 47 patients (32.6%) with suspicious ultrasound lesions. 50% of these patients had no pathological clinical findings, the histological findings of excised lymph nodes were positive in all cases. It must be emphasized, however, that the group with lymph node metastases included 12 patients with low-risk-melanomas (2 x Tis, 10 x T1 historical control group (141 patients), where ELND was performed routinely in high-risk-patients ( > T2), the incidence of ELND in our hospital decreased more than 50%; at the same time the percentage of detected lymph node metastases increased (twice).

  2. Myocardial response to a triathlon in male athletes evaluated by Doppler tissue imaging and biochemical parameters

    DEFF Research Database (Denmark)

    Leetmaa, T H; Dam, A; Glintborg, D

    2008-01-01

    (cTnT) and pro-brain natriuretic peptide (pro-BNP)] and echocardiography. Conventional echocardiography techniques and new Doppler tissue imaging (DTI) modalities were applied before and immediately after the competition. Blood samples were drawn 1 week before, immediately after and 12-24 h post...... and systolic velocities decreased, thus suggesting reversible cardiac fatigue. When using cardiac markers and echocardiographic findings, a triathlon was found to have no significant negative effects on left ventricular function or myocardial tissue in male athletes....

  3. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Science.gov (United States)

    Bull, Sacha; Newton, James

    2017-01-01

    Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities. PMID:28096184

  4. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Directory of Open Access Journals (Sweden)

    Malgorzata Wamil MD PhD

    2017-03-01

    Full Text Available Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities.

  5. Indicaciones básicas para la realización de ecocardiografía-Doppler-color Basic indications for the performance of color Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Fernando Manzur

    2005-06-01

    physiopathology give sufficient bases for the clinical decision assessment and emphasizes the evidence’s examination for the clinical investigation. The comprehension of certain evidence rules is necessary for the correct interpretation of literature in respect to the causes, diagnostic tools and treatment strategies. The main aim of this research is to make a protocol for the indications of an echocardiogram in the clinical practice and to educate our country’s general physicians in this conduct. The good practice is due to initiatives, activities and functional models that are in progress worldwide, as confirmed by evidence. Objective: echocardiography is actually the gold standard for the study of heart anatomy and physiology. Since its introduction in the clinical practice more than three decades ago, it has had such diffusion that it is considered an important tool in the cardiology assistance. It provides trustworthy functional anatomic information, as well as diagnosis and is decisive in the treatment and resolution of cardiovascular diseases. The progressive development of this technique has enabled its use in all the different fields that may affect the cardiovascular system. The objective is to help the clinical physicians in the making of decisions in concrete situations, guaranteeing them that the diagnosis is based on results given by valid scientific studies. In accordance to this, different studies as well as task force and management guides representative of the worldwide literature, were compiled.

  6. Integrated quadruple stress echocardiography.

    Science.gov (United States)

    Picano, Eugenio; Morrone, Doralisa; Scali, Maria C; Huqi, Alda; Coviello, Katia; Ciampi, Quirino

    2018-04-11

    Stress Echocardiography (SE) is an established diagnostic technique. For 40 years, the cornerstone of the technique has been the detection of regional wall motion abnormalities (RWMA), due to the underlying physiologically-relevant epicardial coronary artery stenosis. In the last decade, three new parameters (more objective than RWMA) have shown the potential to integrate and comple- ment RWMA: 1- B-lines, also known as ultrasound lung comets, as a marker of extra-vascular lung water, measured using lung ultrasound with the 4-site simplified scan symmetrically of the antero- lateral thorax on the third intercostal space, from mid-axillary to anterior axillary and mid- clavicular line; 2-left ventricular contractile reserve (LVCR), assessed as the peak stress/rest ratio of left ventricular force, also known as elastance (systolic arterial pressure by cuff sphygmomanome- ter/end-systolic volume from 2D echocardiography); 3- coronary flow velocity reserve (CFVR) on left anterior descending coronary artery, calculated as peak stress/rest ratio of diastolic peak flow velocity assessed using pulsed-wave Doppler. The 4 parameters (RWMA, B-lines, LVCR and CFVR) now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-SE. IQ-SE optimizes the versatility of SE to include in a one-stop shop the core "ABCD" (Asynergy+B-lines+Contractile reserve+Doppler flowmetry) protocol. It allows a synoptic assess- ment of parameters mirroring the epicardial artery stenosis (RWMA), interstitial lung water (B- lines), myocardial function (LVCR) and small coronary vessels (CFVR). Each variable has a clear clinical correlate, different and complementary to all others: RWMA identify an ischemic vs non- ischemic heart; B-lines a wet vs dry lung; LVCR a strong vs weak heart; CFVR a warm vs cold heart. IQ-SE is highly feasible, with minimal increase in the imaging and analysis time, and obvi- ous diagnostic and prognostic impact also beyond coronary artery

  7. Cardiac Time Intervals Measured by Tissue Doppler Imaging M-mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Schnohr, Peter

    2016-01-01

    function was evaluated in 1915 participants by using both conventional echocardiography and tissue Doppler imaging (TDI). The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT), and ejection time (ET), were obtained by TDI M-mode through the mitral......). Additionally, they displayed a significant dose-response relationship, between increasing severity of elevated blood pressure and increasing left ventricular mass index (P

  8. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  9. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  10. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ryohei Suzuki

    2018-02-01

    Full Text Available Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI. The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous.

  11. Tissue Doppler echocardiography reveals impaired cardiac function in patients with reversible ischaemia

    DEFF Research Database (Denmark)

    Hoffmann, Søren; Mogelvang, Rasmus; Sogaard, Peter

    2011-01-01

    AIMS: To determine if echocardiographic tissue Doppler imaging (TDI) performed at rest detects reduced myocardial function in patients with reversible ischaemia. METHODS AND RESULTS: Eighty-four patients with angina pectoris, no previous history of ischaemic heart disease and normal left ventricu...

  12. Spectral Doppler interrogation of the patent foramen ovale-a window to left heart hemodynamics.

    Science.gov (United States)

    Fadel, Bahaa M; Husain, Aysha; Bakarman, Hatem; Dahdouh, Ziad; Salvo, Giovanni Di; Mohty, Dania

    2015-02-01

    Spectral Doppler interrogation of flow across a patent foramen ovale (PFO) allows recording of the instantaneous pressure gradient between left and right atrium (RA). The assessment of RA pressure using the size and collapsibility of the inferior vena cava would thus allow estimation of left atrial (LA) pressure. In this article, we illustrate the value of spectral Doppler interrogation of flow across the PFO by transthoracic echocardiography as a novel and simple tool for the assessment of LA pressure and left cardiac hemodynamics in addition to the conventional noninvasive parameters. © 2014, Wiley Periodicals, Inc.

  13. Invasive and noninvasive assessment of pulmonic regurgitation: clinical, angiographic, phonocardiographic, echocardiographic, and Doppler ultrasound correlations.

    Science.gov (United States)

    Chandraratna, P A; Wilson, D; Imaizumi, T; Ritter, W S; Aronow, W S

    1982-06-01

    Three patients with pulmonic regurgitation and no evidence of pulmonary hypertension were investigated. These patients had low pitched diastolic murmurs which increased on inspiration, evidence of connective tissue disease as manifested by lax joints and hyperextensible skin, and marked hilar dance which extended up to the peripheral vessels. Suprasternal echocardiography revealed dilatation and increased systolic expansion of the right pulmonary artery (RPA) (25% and 28%, respectively) in two patients; the third patient had a normal RPA dimension in diastole and a marked increase in diameter (88%) in systole. Thus, these three patients demonstrated hyperdistensibility of the RPA. The spectral signal from the pulsed doppler echocardiograph showed evidence of turbulent blood flow in diastole (wide dispersion of the dots) in the right ventricular outflow tract in all three patients. This pattern was indicative of pulmonic regurgitation. In summary, the combined use of echocardiography and Doppler ultrasound is useful in the evaluation of patients with pulmonic regurgitation.

  14. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  15. Transesophageal echocardiography in the assessment of coronary arteries; Echokardiografia przezprzelykowa w ocenie proksymalnych odcinkow naczyn wiencowych

    Energy Technology Data Exchange (ETDEWEB)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M. [Akademia Medyczna, Lodz (Poland)

    1993-12-31

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author) 21 refs, 8 figs

  16. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  17. Predicting Paroxysmal Atrial Fibrillation in Cerebrovascular Ischemia Using Tissue Doppler Imaging and Speckle Tracking Echocardiography

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Jørgensen, Peter Godsk; Møgelvang, Rasmus

    2016-01-01

    BACKGROUND: Often the underlying cause of cerebral ischemia (CI) cannot be found during a routine diagnostic investigation, but paroxysmal atrial fibrillation (PAF) could be the culprit. AIM: The objective of the study is to investigate whether advanced echocardiography improves the diagnostic ap...

  18. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  19. Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position

    Science.gov (United States)

    Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.

    2015-01-01

    Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063

  20. What Is Echocardiography?

    Science.gov (United States)

    ... Intramural Research Home / Echocardiography Echocardiography Also known as Echo , Surface echo , Ultrasound of ... other tests, echo doesn't involve radiation. Transthoracic Echocardiography Transthoracic (tranz-thor-AS-ik) echo is the ...

  1. The importance of echocardiography in diagnostics of idiopathic pulmonary arterial hypertension: A case report

    Directory of Open Access Journals (Sweden)

    Stojković Gabrijela

    2011-01-01

    Full Text Available Introduction. Idiopathic pulmonary arterial hypertension (IPAH is rare and difficult progressive disease with prevalence of approximately 15 cases per million residents, with predominant female cases. Case Outline. A 47-year-old female presented with symptoms and signs of the right heart chambers failure. Over prior seven years the patient had the feeling of suffocation and fatigue when walking, and received treatment for bronchial asthma. Physical examination revealed a marked loud second heart sound over the pulmonary artery. Electrocardiogram: right ventricular hypertrophy. Spirometric (pulmonary capacity test, cardiac perfusion scan and spiral CT scanning excluded secondary pulmonary arterial hypertension. Blood testing for connective tissue diseases and HIV were within normal reference limits. Transthoracic colour Doppler echocardiography demonstrated a mild tricuspid regurgitation with high values of estimated maximal and middle systolic pressure of the right ventricle (135/110 mm Hg, and excluded previous heart disease. Cardiac catheterization confirmed IPAH diagnosis, with systolic right ventricular pressure of 101/47/66 mm Hg and pulmonary capillary pressure of 30/13/10 mm Hg. Basic therapy with sildenafil, nevertheless, considerable limitations of strain tolerance was still present. Conclusion. IPAH is a severe heart disease with non-specific signs and symptoms. Screening for IPAH is transthoracic colour Doppler echocardiography shows high correlation with cardiac catheterization.

  2. Retinopathy is associated with impaired myocardial function assessed by advanced echocardiography in type 1 diabetes patients – The Thousand & 1 Study

    DEFF Research Database (Denmark)

    Nouhravesh, Nina; Andersen, Henrik U; Jensen, Jan S

    2016-01-01

    AIMS: Retinopathy and heart disease in Type 1 Diabetes Mellitus (Type 1 DM) may be associated; however previous results have been conflicting. Tissue Doppler Imaging (TDI) and speckle-tracking echocardiography (STE) quantify myocardial function not assessable by conventional echocardiography. We...... investigated the association between severity of retinopathy and early myocardial dysfunction using conventional echocardiography, TDI and STE in Type 1 DM patients. METHODS: Type 1 Diabetes Mellitus patients without known heart disease were included from the Steno Diabetes Center. The cross sectional...... association between retinopathy and myocardial function was analyzed in uni-and multivariable models. Retinopathy was categorized as nil-, simplex- or proliferative retinopathy. RESULTS: A total of 1090 Type 1 Diabetes Mellitus patients were included, mean age was 49.6years and 53% were males. Left...

  3. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis

    Directory of Open Access Journals (Sweden)

    Nádia Martins

    2016-04-01

    Full Text Available Giant Cell Arteritis (GCA is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  4. The use of the color Doppler ultrasonography in the diagnosis and monitoring of an atypical case of giant-cell arteritis.

    Science.gov (United States)

    Martins, N; Polido-Pereira, J; Rodrigues, A M; Soares, F; Batista, P; Pereira da Silva, J A

    2016-01-01

    Giant Cell Arteritis (GCA) is a large vessels vasculitis that is typically characterised by headache, scalp tenderness, jaw claudication and visual disturbances. Temporal arteries color Doppler ultrasonography (CDUS) is a sensitive and non-invasive image technique used in the diagnosis of this disease. This work highlights the importance of CDUS in the diagnostic workup of GCA and also demonstrates it´s usefullness in the evaluation and documentation of the response to corticosteroids therapy in an atypical case of ACG.

  5. Demonstration of blood flow by color doppler in the femoral artery distal to arterial cannula during peripheral venoarterial-extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    K G Suresh Rao

    2017-01-01

    Full Text Available In spite of distal perfusion of the limb using a cannula, the limb can have ischemic events if there is an undetected kink or clot anywhere in the line or thrombus in the artery. There are several ways to monitor and assess the limb ischemia. Monitoring for clinical signs of limb ischemia like temperature change and pallor is reliable and mandatory. We report a method where we used color Doppler to document the blood flow. Curvilinear vascular probe of an echo machine is used to identify the flow in the distal femoral artery of the lower limb. . As we have demonstrated in the video attached, once flow to the distal limb perfusion system is shut off by closing the three way stop cock, we can appreciate the immediate cessation of flow in the artery by Doppler.

  6. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  7. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  8. OPPORTUNITIES OF TRANSVAGINAL ECHOCARDIOGRAPHY FOR EARLY PRENATAL DIAGNOSIS OF INBORN HEART DISEASES IN FETUS

    Directory of Open Access Journals (Sweden)

    E.A. Shevchenko

    2008-01-01

    Full Text Available According to the literature data, transvaginal echocardiography (Echocg is the method, used for the doppler diagnostics in early terms of pregnancy (if principles of safety are observed. This method allows detecting about 70–97% of all prognostic cally significant inborn heart diseases in fetus, beginning at 12 week of pregnancy. a scheme of research includes estimation of four chamber cut of fetus heart, and study of state of its main arteries. This is an expert investigation, because it needs special grounding of specialist, high resolution ultrasonic equipment, and considerable expense of time. Wile parameters are estimated, it is necessary to use normative rates of sizes of ventricles and main arteries of fetus, developed by Russian experts, taking into account individual variations.Key words: transvaginal echocardiography, diagnosis, inborn heart disease.

  9. Fetal echocardiography

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007340.htm Fetal echocardiography To use the sharing features on this page, please enable JavaScript. Fetal echocardiography is a test that uses sound waves ( ultrasound ) ...

  10. 'Focal thyroid inferno' on color Doppler ultrasonography: A specific feature of focal Hashimoto's thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xianshui, E-mail: fuxs1968@163.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Guo, Limei, E-mail: guolimei@bjmu.edu.cn [Department of Pathology, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Zhang, Huabin, E-mail: huabinzhang@bjmu.edu.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Ran, Weiqiang, E-mail: ranwq-sina@vip.sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Fu, Peng, E-mail: fupeng01@gmail.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Li, Zhiqiang, E-mail: lizhq126@126.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Chen, Wen, E-mail: wendy7989@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jiang, Ling, E-mail: papayaling@yahoo.com.cn [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China); Jia, Jianwen, E-mail: drjia88@sohu.com [Department of Ultrasound, Peking University Third Hospital, 49 Huayuanbeilu Road, Beijing 100191 (China)

    2012-11-15

    Purpose: To evaluate color-Doppler features predictive of focal Hashimoto's thyroiditis. Materials and methods: A total of 521 patients with 561 thyroid nodules that underwent surgeries or gun biopsies were included in this study. These nodules were divided into three groups: focal Hashimoto's thyroiditis (104 nodules in 101 patients), benignity other than focal Hashimoto's thyroiditis (73 nodules in 70 patients), and malignancy (358 nodules in 350 patients). On color Doppler sonography, four vascularity types were determined as: hypovascularity, marked internal flow, marked peripheral flow and focal thyroid inferno. The {chi}{sup 2} test was performed to seek the potential vascularity type with the predictive ability of certain thyroid pathology. Furthermore, the gray-scale features of each nodule were also studied. Results: The vascularity type I (hypovascularity) was more often seen in focal Hashimoto's thyroiditis than other benignity and malignancy (46% vs. 20.5% and 19%). While the type II (marked internal flow) showed the opposite tendency (26.9% [focal Hashimoto's thyroiditis] vs. 45.2% [other benignity] and 52.8% [malignancy]). However, type III (marked peripheral flow) was unable to predict any thyroid pathology. Importantly, type IV (focal thyroid inferno) was exclusive to focal Hashimoto's thyroiditis. All 8 type IV nodules appeared to be solid, hypoechoic, and well-defined. Using 'focal thyroid inferno' as an indicator of FHT, the diagnostic sensitivity and specificity were 7.7% and 100% respectively. Conclusions: The vascularity type of 'focal thyroid inferno' is specific for focal Hashimoto thyroiditis. Recognition of this particular feature may avoid unnecessary interventional procedures for some solid hypoechoic thyroid nodules suspicious of malignancy.

  11. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  12. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  13. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  14. Relation of isovolumic times after cardiac resynchronization therapy to improvement in exercise capacity

    NARCIS (Netherlands)

    Jansen, A.H.M.; Peels, C.H.; Bracke, F.A.L.E.; Dantzig, van J.M.; Meijer, A.; van der Voort, P.H.; Gelder, van L.M.; Korsten, H.H.M.; Hemel, van N.M.

    2007-01-01

    M-mode echocardiography (using the septal-to-posterior wall motion delay [SPWMD]) and color-coded tissue Doppler imaging (TDI; using the septal-to-lateral delay in peak systolic velocity) have been proposed for assessment of left ventricular (LV) dyssynchrony and prediction of response to cardiac

  15. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  16. Assessment of regional systolic and diastolic myocardial function using tissue Doppler and strain imaging in dogs with dilated cardiomyopathy.

    Science.gov (United States)

    Chetboul, Valérie; Gouni, Vassiliki; Sampedrano, Carolina Carlos; Tissier, Renaud; Serres, François; Pouchelon, Jean-Louis

    2007-01-01

    Tissue Doppler Imaging (TDI) or strain (St) imaging could provide sensitive indices for early detection and treatment follow-up of canine dilated cardiomyopathy (DCM). Analysis of TDI and St features in dogs with overt DCM is a prerequisite before using these new criteria in prospective screenings of predisposed families or in clinical trials. Radial and longitudinal right and left myocardial motion, assessed by TDI and St variables, is altered in dogs with DCM. Case records for 26 dogs; 14 with DCM and 12 healthy controls of comparable age and weight were reviewed. A retrospective analysis was conducted of conventional echocardiography, 2-dimensional color TDI, and St imaging data. The DCM group was characterized by decreases in radial and longitudinal systolic velocity gradients of the left ventricular free wall (LVFW), radial and longitudinal absolute values of peak systolic St of the LVFW, and longitudinal systolic right ventricular (RV) velocities (all P canine DCM.

  17. Airborne Doppler Wind Lidar Post Data Processing Software DAPS-LV

    Science.gov (United States)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable post processing of airborne Doppler wind LIDAR data. In an embodiment, airborne Doppler wind LIDAR data software written in LabVIEW may be provided and may run two versions of different airborne wind profiling algorithms. A first algorithm may be the Airborne Wind Profiling Algorithm for Doppler Wind LIDAR ("APOLO") using airborne wind LIDAR data from two orthogonal directions to estimate wind parameters, and a second algorithm may be a five direction based method using pseudo inverse functions to estimate wind parameters. The various embodiments may enable wind profiles to be compared using different algorithms, may enable wind profile data for long haul color displays to be generated, may display long haul color displays, and/or may enable archiving of data at user-selectable altitudes over a long observation period for data distribution and population.

  18. [Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].

    Science.gov (United States)

    Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P

    1996-01-01

    Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.

  19. Doppler echocardiographic evaluation of HIV-positive patients in different stages of the disease

    Directory of Open Access Journals (Sweden)

    Werneck Guilherme Lobosco

    1999-01-01

    Full Text Available OBJETIVE: To evaluate by Doppler echocardiography (DE early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A and 25 with CD4 cell count 500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³, had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

  20. Transcranial Doppler and transesophageal echocardiography: comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection.

    Science.gov (United States)

    Caputi, Luigi; Carriero, Maria Rita; Falcone, Chiara; Parati, Eugenio; Piotti, Patrizia; Materazzo, Carlo; Anzola, Gian Paolo

    2009-01-01

    Patent foramen ovale (PFO) has been investigated in several conditions apart from cryptogenic ischemic stroke. Contrast transesophageal echocardiography (cTEE) is the gold standard for the diagnosis, although it has some known limitations. Contrast transcranial Doppler (cTCD) allows a semiquantitative estimation of right-to-left shunt (RLS) volume. The aims of our study were to confirm the diagnostic accuracy of cTCD in PFO diagnosis and to compare the abilities of cTCD and cTEE to detect a RLS and PFO, respectively, under normal breathing. The latter could represent an important feature for its clinical significance. A total of 100 consecutive patients (59 women and 41 men, age 46 +/- 12 years) were evaluated after stabilized ischemic stroke/transient ischemic attack, migraine, and lacunae, and before neurosurgery in sitting position. All patients undertook cTEE and cTCD, at rest and under Valsalva maneuver (VM). cTEE under VM was the reference standard. A categorization of patients and a semiquantitative cTCD classification were proposed. In all, 63 of 100 patients had PFO diagnosed by cTEE. A general concordance of up to 90% between both techniques was found. cTCD sensitivity and specificity were 96.8% and 78.4%, respectively. In 17 of 100 patients with cTEE-proven PFO under VM, cTCD and cTEE detected RLS at rest in 75% (95% confidence interval [CI] 62%-85%) and 48% (95% CI 35%-61%) of cases, respectively (P < .001). cTEE disclosed RLS at rest in about 71% (95% CI 9%-42%) of cTCDs showing a "shower-curtain" pattern and only in about 22% (95% CI 52%-85%) of those cTCDs without that pattern. In diagnosing PFO, cTCD has a good accuracy compared with cTEE. To detect a RLS at rest, cTCD appears to be more sensitive than cTEE. The latter resulted positive under normal breathing, mostly in cases of significant RLS at cTCD. Our results point out the impact of cTCD in the evaluation of RLS volume, thus aiding, in association with the anatomic details by cTEE, in the

  1. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    International Nuclear Information System (INIS)

    Ozturk, Adil; Ozturk, Ebru; Zeyrek, Fadile; Onur, Kahraman; Sirmatel, Ocal; Kat, Nurcan

    2005-01-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  2. Comparison of brucella and non-specific epididymorchitis: gray scale and color Doppler ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Ozturk, Adil [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)]. E-mail: ozturka26@hotmail.com; Ozturk, Ebru [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Zeyrek, Fadile [Department of Microbiology, Harran University School of Medicine, Sanliurfa (Turkey); Onur, Kahraman [Department of Urology, SSK Sanliurfa Hastanesi, Sanliurfa (Turkey); Sirmatel, Ocal [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey); Kat, Nurcan [Department of Radiology, Harran University School of Medicine, Arastirma ve Uygulama Hastanesi, TR-63100 Sanliurfa (Turkey)

    2005-11-01

    Objective: The aim of this study is to find out if it is possible to differentiate between brucellar and non-specific epididymorchitis by comparing ultrasonography (US) and color Doppler ultrasonography (CDUS) findings. Material and methods: Fifty-six patients diagnosed to have epididymorchitis both clinically and ultrasonographically were included to study. All of the patients were investigated serologically for brucella. Twenty-eight of those patients were admitted brucella epididymorchitis because of high agglutinations titers for brucella. The other 28 patients were admitted non-specific epididymorchitis because of normal agglutinations titers for brucella. Testicular size, echogenicity, hydrocele, internal echoes and/or septations within hydrocele, and scrotal skin thickness of normal and involved testis were compared by ultrasonography. Besides, pick systolic velocity, end diastolic velocity, resistive index and pick systolic velocity ratio values were measured by bilateral testicular color Doppler ultrasonography in both groups. When the p-value is <0.05, the difference between groups is accepted as statistically significant. Results: Thickening of scrotal skin was seen in 17 of 28 patients with brucella epididymorchitis (BEPO) (67%) and in 25 of 28 patients with non-specific epididymorchitis (NEPO) (89.2%) (p < 0.01). There was no difference between groups regarding presence of hydrocele. However hydrocele seen in all patients was anechoic except for two patients (8.6%). Hydrocele seen in 18 of 22 patients with BEPO and hydrocele had internal echogenicity or septation (p < 0.001). Sizes of testes and epididymis were found to be increased in involved testis compared to normal testis. Testes of all patients with NEPO were homogenous with decreased echogenicity except for five patients (17.8%). However, 23 patients with BEPO (82%) found to have heterogenous testis (p < 0.001). Spectral measurements showed increased PSV and EDV values and decreased RI values in

  3. Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

    Science.gov (United States)

    Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A

    2009-06-01

    The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler. 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%). Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester. (c) 2009 ISUOG.

  4. Performance of two-dimensional Doppler echocardiography for the assessment of infarct size and left ventricular function in rats

    Directory of Open Access Journals (Sweden)

    Nozawa E.

    2006-01-01

    Full Text Available Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes, infarct size (percentage of the arc with infarct on 3 transverse planes, systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient. Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005. The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction to 53.1 ± 1.5% (control and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001 and histology (r = -0.78; P < 00001. The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7 was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3. There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

  5. Combined computational and experimental approach to improve the assessment of mitral regurgitation by echocardiography.

    Science.gov (United States)

    Sonntag, Simon J; Li, Wei; Becker, Michael; Kaestner, Wiebke; Büsen, Martin R; Marx, Nikolaus; Merhof, Dorit; Steinseifer, Ulrich

    2014-05-01

    Mitral regurgitation (MR) is one of the most frequent valvular heart diseases. To assess MR severity, color Doppler imaging (CDI) is the clinical standard. However, inadequate reliability, poor reproducibility and heavy user-dependence are known limitations. A novel approach combining computational and experimental methods is currently under development aiming to improve the quantification. A flow chamber for a circulatory flow loop was developed. Three different orifices were used to mimic variations of MR. The flow field was recorded simultaneously by a 2D Doppler ultrasound transducer and Particle Image Velocimetry (PIV). Computational Fluid Dynamics (CFD) simulations were conducted using the same geometry and boundary conditions. The resulting computed velocity field was used to simulate synthetic Doppler signals. Comparison between PIV and CFD shows a high level of agreement. The simulated CDI exhibits the same characteristics as the recorded color Doppler images. The feasibility of the proposed combination of experimental and computational methods for the investigation of MR is shown and the numerical methods are successfully validated against the experiments. Furthermore, it is discussed how the approach can be used in the long run as a platform to improve the assessment of MR quantification.

  6. Nutcracker Syndrome Accompanying Pelvic Congestion Syndrome; Color Doppler Sonography and Multislice CT Findings: A Case Report

    International Nuclear Information System (INIS)

    Inal, Mikail; Karadeniz Bilgili, Mihrace Yasemin; Sahin, Safa

    2014-01-01

    Nutcracker syndrome (NCS) is a rare pathology, caused by compression of the left renal vein (LRV) between the abdominal aorta (AA) and the superior mesenteric artery (SMA), due to reduction of the angle between AA and SMA. This leads to LRV varices, left gonadal vein varices and therefore, the pelvic congestion syndrome. For this reason, coexistence of NCS and pelvic congestion syndrome has been described. It manifests by hematuria, proteinuria, and nonspecific pelvic pain secondary to pelvic congestion, dyspareunia and persistent genital arousal. We report a 27-year-old woman who experienced hematuria and left flank pain. The diagnosis of NCS accompanied by pelvic congestion syndrome was missed initially, but later on the diagnosis was made by color Doppler ultrasound, abdominal computed tomography (CT) and CT angiography that were later performed. She refused interventional and surgical treatments, and was lost to follow up

  7. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo [Keimyung University School of Medicine, Taegu (Korea, Republic of); Kim, Jung Sik [Radiological Clinic, Taegu (Korea, Republic of)

    2002-06-15

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  8. Three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Buck, Thomas

    2011-01-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  9. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    Science.gov (United States)

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  10. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    Science.gov (United States)

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  11. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  12. Coronary flow velocity reserve by echocardiography

    DEFF Research Database (Denmark)

    Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Snoer, Martin

    2016-01-01

    BACKGROUND: Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography of the LAD is used to assess microvascular function but validation studies in clinical settings are lacking. We aimed to assess feasibility, reproducibility and agreement with myocardial flow...... performed within a week (1-week) and for all scans regardless of time gap (total) and to account for scar tissue for patients with and without previous myocardial infarction (MI). RESULTS: Eighty-six patients with median BMI 30.9 (IQR 29.4-32.9) kg × m(-2) and CFVR 2.29 (1.90-2.63) were included. CFVR...... was feasible in 83 (97 %) using a contrast agent in 14 %. For reproducibility overall (n = 21) limits of agreement (LOA) were (-0.75;0.71), within-subjects coefficient of variation (CV) 11 %, and reliability 0.84. For reproducibility within 1-week (n = 13) LOA were (-0.33;0.25), within-subjects CV 5...

  13. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Doppler echocardiographic study in adolescents and young adults with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Wolney de Andrade Martins

    1999-12-01

    Full Text Available OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA. METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS. The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

  15. Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

    Science.gov (United States)

    Sitges, Marta; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Tsujino, Hiroyuki; Bauer, Fabrice; Kim, Yong Jin; Agler, Deborah A.; Cardon, Lisa A.; Zetts, Arthur D.; hide

    2003-01-01

    BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

  16. Ultrasonography and color Doppler of proximal gluteal enthesitis in juvenile idiopathic arthritis: a descriptive study

    Directory of Open Access Journals (Sweden)

    Thomsen Carsten

    2011-08-01

    Full Text Available Abstract Background The presence of enthesitis (insertional inflammation in patients with juvenile idiopathic arthritis (JIA is difficult to establish clinically and may influence classification and treatment of the disease. We used ultrasonography (US and color Doppler (CD imaging to detect enthesitis at the small and deep-seated proximal insertion of the gluteus medius fascia on the posterior iliac crest where clinical diagnosis is difficult. The findings in JIA patients were compared with those obtained in healthy controls and with the patients' MRI results. Methods Seventy-six proximal gluteus medius insertions were studied clinically (tenderness to palpation of the posterior iliac crest and by US and CD (echogenicity, thickness, hyperemia in 38 patients with JIA and in 38 healthy controls, respectively (median age 13 years, range 7-18 years. In addition, an additional MRI examination of the sacroiliac joints and iliac crests was performed in all patients. Results In patients with focal, palpable tenderness, US detected decreased echogenicity of the entheses in 53% of the iliac crests (bilateral in 37% and unilateral in 32%. US also revealed significantly thicker entheses in JIA patients compared to healthy controls (p Conclusions According to US, the gluteus medius insertion was thicker in JIA patients than in controls, and it was hypoechoic (enthesitis in about half of the patients. These findings may represent chronic, inactive disease in some of the patients, because there was only limited Doppler flow and MRI contrast enhancement. The present study indicates that US can be useful as an adjunct to clinical examination for improved assessment of enthesitis in JIA. This may influence disease classification, ambition to treat, and choice of treatment regimen.

  17. Determinants of Pediatric Echocardiography Laboratory Productivity: Analysis from the Second Survey of the American Society of Echocardiography Committee on Echocardiography Laboratory Productivity.

    Science.gov (United States)

    Srivastava, Shubhika; Allada, Vivekanand; Younoszai, Adel; Lopez, Leo; Soriano, Brian D; Fleishman, Craig E; Van Hoever, Andrea M; Lai, Wyman W

    2016-10-01

    The American Society of Echocardiography Committee on Pediatric Echocardiography Laboratory Productivity aimed to study factors that could influence the clinical productivity of physicians and sonographers and assess longitudinal trends for the same. The first survey results indicated that productivity correlated with the total volume of echocardiograms. Survey questions were designed to assess productivity for (1) physician full-time equivalent (FTE) allocated to echocardiography reading (echocardiograms per physician FTE per day), (2) sonographer FTE (echocardiograms per sonographer FTE per year), and (3) machine utilization (echocardiograms per machine per year). Questions were also posed to assess work flow and workforce. For fiscal year 2013 or academic year 2012-2013, the mean number of total echocardiograms-including outreach, transthoracic, fetal, and transesophageal echocardiograms-per physician FTE per day was 14.3 ± 5.9, the mean number of echocardiograms per sonographer FTE per year was 1,056 ± 441, and the mean number of echocardiograms per machine per year was 778 ± 303. Both physician and sonographer productivity was higher at high-volume surgical centers and with echocardiography slots scheduled concordantly with clinic visits. Having an advanced imaging fellow and outpatient sedation correlated negatively with clinical laboratory productivity. Machine utilization was greater in laboratories with higher sonographer and physician productivity and lower for machines obtained before 2009. Measures of pediatric echocardiography laboratory staff productivity and machine utilization were shown to correlate positively with surgical volume, total echocardiography volumes, and concordant echocardiography scheduling; the same measures correlated negatively with having an advanced imaging fellow and outpatient sedation. There has been no significant change in staff productivity noted over two Committee on Pediatric Echocardiography Laboratory

  18. Relaxation and filling of the left ventricle assessed by Doppler echocardiography

    International Nuclear Information System (INIS)

    Myreng, Y.

    1990-01-01

    In patients with coronary disease the Doppler method described in the present work was capable of detecting a delayed left ventricular (LV) relaxation and a shift of LV filling from early towards late diastole. This might reflect changes in LV diastolic function due to myocardial ischemia. Furthermore, the method allowed monitoring of changes during treatment with atenolol and verapamil. These changes indicated that atenolol and verapamil were able to partially correct the relaxation abnormailty and increase the relative contribution of early diastolic filling. Although all the numerous variables that influence LV transmitral filling could be controlled in this noninvasive clinical study, the results suggest that antianginal drugs may have beneficial effect on diastolic function in coronary disease. 62 refs., 3 figs., 4 tabs

  19. A follow-up study of neonatal interatrial shunt with echocardiography until twelve to fifteen months of age.

    Science.gov (United States)

    Ho, Chi-Lin; Jan, Sheng-Ling; Lin, Ming-Chih; Fu, Yun-Ching

    2008-12-01

    To assess the incidence and natural history of full-term neonates with interatrial shunt (IAS). A follow-up study of 1389 neonates who received screening echocardiography between 2003 and 2006. Babies with IAS at 2 to 4 days of life underwent follow-up echocardiography at 2 to 4 months, 6 to 9 months and 12 to 15 months of age until closure of IAS. The ratio of IAS was 68.3% initially. No significant demographic differences were identified between infants with and without initial IAS. Among 949 neonates with initial IAS, 84.5% infants had a left-to-right interatrial shunt, 13.5% had bidirectional shunt and 2% had predominantly right-to-left shunt. The persistence rate of IAS at 12 to 15 months of age was 3.8% (44/1166). The initial size of IAS ranged from 1.2 to 7.7mm (4.3+/-1.1 mm) detected by color Doppler flow mapping and cases were divided into three groups: small ( or =8 mm). There were 74.6% infants in the small group and 25.4% in the medium group initially. The neonates in the initial small group would always see their IAS close or else they would remain in the small group. Those in the final medium and large size groups always came from the initial medium group. The late closure rate of IAS was 93.9% of infants with initial IAS. The closure curves of initial small and medium sized groups were significantly different, and their late closure rates were 95.1% and 90.4%, respectively. IAS was very common during early neonatal stage, but most cases would close after 1 year. The late closure rate of initial IAS was different if using a cutpoint of 5 mm.

  20. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.

  1. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    International Nuclear Information System (INIS)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok; Lee, Yeong Hwan

    1996-01-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm

  2. Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

    Science.gov (United States)

    Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi

    2004-06-01

    Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

  3. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy.

    Science.gov (United States)

    Khan, Sitara G; Klettas, Dimitris; Kapetanakis, Stam; Monaghan, Mark J

    2016-03-01

    Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain) has conventionally been assessed using tissue Doppler imaging (TDI), which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference ('speckles') in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT. © 2016 The authors.

  4. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy

    Directory of Open Access Journals (Sweden)

    Sitara G Khan

    2016-05-01

    Full Text Available Cardiac resynchronisation therapy (CRT can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain has conventionally been assessed using tissue Doppler imaging (TDI, which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference (‘speckles’ in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT.

  5. Stress echocardiography expert consensus statement

    NARCIS (Netherlands)

    R. Sicari (Rosa); P. Nihoyannopoulos (Petros); A. Evangelista (Arturo); J. Kasprzak (Jaroslav); P. Lancellotti (Patrizio); D. Poldermans (Don); J.U. Voigt; J.L. Zamorano (Jose)

    2008-01-01

    textabstractStress echocardiography is the combination of 2D echocardiography with a physical, pharmacological or electrical stress. The diagnostic end point for the detection of myocardial ischemia is the induction of a transient worsening in regional function during stress. Stress echocardiography

  6. 2010 Canadian Cardiovascular Society/Canadian Society of Echocardiography Guidelines for Training and Maintenance of Competency in Adult Echocardiography.

    Science.gov (United States)

    Burwash, Ian G; Basmadjian, Arsene; Bewick, David; Choy, Jonathan B; Cujec, Bibiana; Jassal, Davinder S; MacKenzie, Scott; Nair, Parvathy; Rudski, Lawrence G; Yu, Eric; Tam, James W

    2011-01-01

    Guidelines for the provision of echocardiography in Canada were jointly developed and published by the Canadian Cardiovascular Society and the Canadian Society of Echocardiography in 2005. Since their publication, recognition of the importance of echocardiography to patient care has increased, along with the use of focused, point-of-care echocardiography by physicians of diverse clinical backgrounds and variable training. New guidelines for physician training and maintenance of competence in adult echocardiography were required to ensure that physicians providing either focused, point-of-care echocardiography or comprehensive echocardiography are appropriately trained and proficient in their use of echocardiography. In addition, revision of the guidelines was required to address technological advances and the desire to standardize echocardiography training across the country to facilitate the national recognition of a physician's expertise in echocardiography. This paper summarizes the new Guidelines for Physician Training and Maintenance of Competency in Adult Echocardiography, which are considerably more comprehensive than earlier guidelines and address many important issues not previously covered. These guidelines provide a blueprint for physician training despite different clinical backgrounds and help standardize physician training and training programs across the country. Adherence to the guidelines will ensure that physicians providing echocardiography have acquired sufficient expertise required for their specific practice. The document will also provide a framework for other national societies to standardize their training programs in echocardiography and will provide a benchmark by which competency in adult echocardiography may be measured. Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  7. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    Science.gov (United States)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  8. Evaluation of portal hypertension in cirrhotic patients using color duplex-doppler ultrasound. Preliminary study; Evaluacion de la hipertension portal del cirrotico mediante ultrasonografia duplex-Doppler color. Estudio prliminar

    Energy Technology Data Exchange (ETDEWEB)

    Varas, M J; Torres, G; Sanllely, H [Unidad de Ecografias, Consorcio del Hospital de la Cruz Roja, L` Hospitalet de Llobregat, Barcelona (Spain)

    1996-09-01

    The objective was to compare data obtained by color duplex-Doppler ultrasound (mean velocity, flow and portal vein congestion index) in patients with chronic diffuse liver disease with and without portal hypertension (PH) (demonstrated endoscopically) with that of a healthy control group. Over a two-year period, 50 studies were performed in 10 healthy subjects (control group) with a mean age of 36 years and in 40 chronic liver disease patients (study group with a mean age of 58 years), most of whom presented alcoholic liver cirrhosis and belonged to Child-Pugh class B. They were subdivided according to endoscopic study into patients without (group 1) and with (group 2) portal hypertension. There were statistically significant differences in the diameters of splenic vein, spleen, portal vein and in the portal Vm, which decreased as the Child-Pugh score rose. When the patients without (group 1) and with (group 2) endoscopic evidence of PH (esophageal varices)were analyzed and compared, the two groups presented no statistically significant differences with respect to portal Vm, blood flow out of the liver, presence of collateral vessels, or the portal vein congestion index; the latter was significantly different in both the study group as a whole and in the patients with PH when compared with the control group. Given that this report is based on a pilot study which requires a larger sample number, we are unable to arrive at definitive conclusions. (Author) 18 refs.

  9. Echocardiography in chronic liver disease: systematic review.

    Science.gov (United States)

    Mota, Vitor Gomes; Markman Filho, Brivaldo

    2013-04-01

    Doppler echocardiography (Echo) is a non-invasive method of excellent accuracy to screen portopulmonary hypertension (PPH) and to assess intrapulmonary shunts (IPS) in chronic liver disease (CLD). In the past decade, Echo proved to play a fundamental role in the diagnosis of cirrhotic cardiomyopathy (CCM). To perform a systematic review of relevant articles on the subject 'Echo in CLD'. In November 2011, a systematic review was performed in the PubMed, LILACS and SciELO databases, and the characteristics of the studies selected were reported. The search based on descriptors and free terms obtained 204 articles (179 in Pubmed, 21 in LILACS, and 1 in SciELO). Of those 204 articles, 22 were selected for systematic review. A meta-analysis could not be performed because of the heterogeneity of the articles. Echo should be part of CLD stratification for screening PPH, IPS and CCM, because, most of the time, such complications are diagnosed only when patients are already waiting for a liver transplant.

  10. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact

    Science.gov (United States)

    Simon, Julianna C.; Sapozhnikov, Oleg A.; Kreider, Wayne; Breshock, Michael; Williams, James C., Jr.; Bailey, Michael R.

    2018-01-01

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  11. The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    Science.gov (United States)

    Simon, Julianna C; Sapozhnikov, Oleg A; Kreider, Wayne; Breshock, Michael; Williams, James C; Bailey, Michael R

    2018-01-09

    The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling; however, the hypothesis is not fully accepted because the bubbles have not been directly observed. In this paper, the micron or submicron-sized bubbles predicted by the crevice bubble hypothesis are enlarged in kidney stones of five primary compositions by exposure to acoustic rarefaction pulses or hypobaric static pressures in order to simultaneously capture their appearance by high-speed photography and ultrasound imaging. On filming stones that twinkle, consecutive rarefaction pulses from a lithotripter caused some bubbles to reproducibly grow from specific locations on the stone surface, suggesting the presence of pre-existing crevice bubbles. Hyperbaric and hypobaric static pressures were found to modify the twinkling artifact; however, the simple expectation that hyperbaric exposures reduce and hypobaric pressures increase twinkling by shrinking and enlarging bubbles, respectively, largely held for rough-surfaced stones but was inadequate for smoother stones. Twinkling was found to increase or decrease in response to elevated static pressure on smooth stones, perhaps because of the compression of internal voids. These results support the crevice bubble hypothesis of twinkling and suggest the kidney stone crevices that give rise to the twinkling phenomenon may be internal as well as external.

  12. Pulsed and Tissue Doppler Echocardiographic Changes in Patients with Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Taysir S. Garadah

    2010-01-01

    Full Text Available Background Doppler echocardiographic studies of left ventricle (LV systolic and diastolic function in patients with β-Thalassemia Major (β-TM had shown different patterns of systolic and diastolic dysfunction. Aim This cross-sectional study was designed to study the LV systolic and diastolic function in patients with β-TM using Pulsed Doppler (PD and Tissue Doppler (TD echocardiography. Methods All patients were evaluated clinically and by echocardiography, The study included patients with β-TM (n = 38, age 15.7 ± 8.9 years compared with an age-matched control group (n = 38, age 15.9 ± 8.9 years. The pulse Doppler indices were normalized for age and heart rate. Results Compared with control patients, M-Mode showed that patients with β-TM have thicker LV septal wall index (0.659 ± 0.23 vs. 0.446 ± 0.219 cm, P ≤ 0.001, posterior wall index (0.659 ± 0.235 vs. 0.437 ± 0.214 cm, P ≤ 0.01, and larger LVEDD index is (3.99 ± 0.48 vs. 2.170 ± 0.57 mm. P = 0.035. Pulsed Doppler showed high LV trans-mitral E wave velocity (70.818 ± 10.139 vs. 57.532 ± 10.139, p = 0.027 and E/A ratio (1.54 vs. 1.23, P ≤ 0.01. The duration of Deceleration time (DT and isovolumic relaxation time (IVRT were significantly shorter in patients with β-TM (150.234 ± 20.0.23 vs. 167.123 ± 19.143 msec, P ≤ 0.01 and (60.647 ± 6.77 vs. 75.474 ± 5.83 msec, P ≤ 0.001, respectively. The ratio of transmitral E wave velocity to the tissue Doppler E wave at the basal septal mitral annulus E/Em – was significantly higher in β-TM group (14.024 ± 2.29 vs. 12.132 ± 1.82, P ≤ 0.01. The Tissue Doppler systolic velocity (Sm and the early diastolic velocity (Em were significantly lower in β-TM group compared to control (4.31 ± 1.2 cm/s vs. 6.95 ± 2.1, P ≤ 0.01 and 4.31 ± 2.7 cm/s vs. 5.82 ± 2.5, P ≤ 0.01 respectively. The tricuspid valve velocity was significantly higher than controls (2.993 ± 0.569 vs. 1.93 ± 0.471 m/sec, respectively, P ≤ 0

  13. [Is standard-echocardiography sufficient for identification of responders?].

    Science.gov (United States)

    Neuss, M; Flach, P; Ali, T; Butter, C

    2006-01-01

    During recent years cardiac re-synchronization has become an important tool in the treatment of patients with signs and symptoms of heart failure and de-synchronized contraction of the heart. This article describes the pathophysiological basis of de-synchronized contraction due to left bundle branch block and the use of conventional echocardiography to unmask whether the electrical abnormality is accompanied by an asynchronous contraction in the individual patient. The altered contraction in the de-synchronized heart is analysed on different levels: atrioventricular dyssynchrony describes the disturbed mechanical coupling of the ventricles and atria, interventricular dyssynchrony describes the disturbed mechanical coupling of the left and right ventricle, and intraventricular dyssynchrony describes the uncoordinated contraction of the left ventricle. Since tissue Doppler imaging is implemented only in the top level echo machines of the respective manufacturers, this article uses parameters derived from standard echo techniques to analyse the different aspects of dyssynchrony.

  14. The practice of echocardiography

    International Nuclear Information System (INIS)

    Kraus, R.

    1985-01-01

    This volume is an anthology by noted authorities on all clinically useful aspects of echocardiography. Its articles cover such subjects as: historical perspectives, physics, instrumentation and techniques, M mode and 2D echocardiography

  15. Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography

    NARCIS (Netherlands)

    Salustri, A.; Becker, A. E.; van Herwerden, L.; Vletter, W. B.; ten Cate, F. J.; Roelandt, J. R.

    1996-01-01

    This study was done to ascertain whether three-dimensional echocardiography can facilitate the diagnosis of mitral valve abnormalities. The value of the additional information provided by three-dimensional echocardiography compared with two-dimensional multiplane transesophageal echocardiography for

  16. American Society of Echocardiography

    Science.gov (United States)

    American Society of Echocardiography Join Ase Renew Member Portal Log In Membership Member Portal Log In Join ASE Renew Benefits Rates FASE – Fellow of the American Society of Echocardiography Member Referral Program FAQs Initiatives Advocacy Awards, Grants, ...

  17. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  18. Renal transplant assessment with color and pulsed ultrasonography. 1st part: surgical complications

    International Nuclear Information System (INIS)

    Martin Hervas, C.; Gil de Miguel, A.

    1994-01-01

    Color duplex Doppler ultrasound (US) is a highly important technique in kidney transplantation (Tx). We have performed 304 serial explorations in 140 transplant recipients assessing the morphological aspect of the graft, possible dilatation of the urinary tract and collections. Subsequently, we used color and pulsed Doppler to study the renal vascular permeability and the parenchymal resistance, calculating the indices of resistance (RI) and systolic acceleration and the frequencies. We have compared these findings with those observed in a control group of 45 patients with normally functioning grafts and we have also compared them according to the different pathologies, with those of other diagnostic imaging techniques to identify the present role of each in the assessment of kidney transplantation. Plain US plays an important role in the detection of dilations and peri renal collections, and Doppler makes it possible to differentiate, in some cases, obstructive from non obstructive dilatation. The US features of collections are nonspecific. In pulsed Doppler US, the lymphocytes present slightly elevated RI, higher than those produced in secondary dilation, in abscess-related processes and in sub capsular collections with parenchymal compromise. Color duplex Doppler is of greatest use in the diagnosis of vascular complications of Tx, especially thrombosis, stenosis and A-V fistulas. (Author)

  19. Right Ventricular Doppler Echocardiographic Study of Indeterminate Form of Chagas Disease

    Directory of Open Access Journals (Sweden)

    Rogério Gomes Furtado

    2015-03-01

    Full Text Available Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D, 92 patients were assessed and divided into two groups: group I (normal, n = 31 and group II (ICD/CN, n = 61. Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%, mobility of the tricuspid annulus (0.0% versus 0.0%, and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016. The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099 and pulsed Doppler (61.3% versus 68%, p = 0.141 and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%, pseudonormal pattern (0.0% versus 0.0%, and restrictive pattern (0.0% versus 0.0% was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables, suggesting incipient changes in RV systolic function in the ICD/CN group.

  20. Primary chronic venous insufficiency of the lower extremities: preoperative color duplex Doppler ultrasound study

    International Nuclear Information System (INIS)

    Selfa, S.; Diago, T.; Ricart, M.; Chulia, R.; Martin, F.

    2000-01-01

    To asses the role of color duplex Doppler ultrasound (CDU) in the preoperative study of patients with varicose veins in lower extremities. We employed CDU to examine varicose veins in 342 lower limbs, assessing reflux in saphenous veins (SV), deep venous system (DVS) and perforating veins (PV). We analyzed the relationship between the anatomical extent of the reflux and the clinical findings. Insufficiency of the superficial venous system alone was uncommon, occurring in only 10.8% of the limbs examined. Reflux was observed in SV and PV in 48.2% of the legs. It was detected in all three systems in 29.2% of cases. The presence of reflux in more than one system and more than one value was associated with increased clinical severity. The site of venous reflux in lower extremities with varicose veins varies. Greater clinical severity is observed in the presence of more marked reflux in the DVS and PV. CDU provides anatomic and functional data on the three venous systems of the lower limbs, allowing an individualized therapeutic surgery. Preoperative localization of incompetent PV by means of CDU facilities their ligation. CDU is the technique of choice for the preoperative examination of the venous systems of patients with varicose veins. (Author)

  1. Echocardiography-guided or "sided" pericardiocentesis.

    Science.gov (United States)

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  2. Two dimensional and Doppler echocardiographic evaluation of patients presenting at Obafemi Awolowo University Teaching Hospitals Complex Ile Ife Nigeria a prospective study of 2501 subjects

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2013-07-01

    Full Text Available Rasaaq Ayodele Adebayo,1 Patience Olayinka Akinwusi,2 Michael Olabode Balogun,1 Anthony Olubunmi Akintomide,1 Victor Oladeji Adeyeye,1 Olugbenga Olusola Abiodun,1 Luqman Adeleke Bisiriyu,3 Suraj Adefabi Ogunyemi,1 Ebenezer Adekunle Ajayi,4 Olufemi Eyitayo Ajayi,1 Adebayo Tolulope Oyedeji5 1Cardiology Unit, Department of Medicine, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, 2Cardiology Unit, Department of Medicine, Osun State University, Osogbo, Osun State, 3Department of Demography and Social Statistics, Obafemi Awolowo University, Ile-Ife, Osun State, 4Cardiology Unit, Department of Medicine, Ekiti State University Teaching Hospital, Ado-Ekiti, Ekiti State, 5Cardiology Unit, Department of Medicine, LAUTECH Teaching Hospital, Osogbo, Osun State, Nigeria Background: Echocardiography remains a key noninvasive cardiac investigative tool in the management of patients, especially in a developing economy like Nigeria. In this study, we investigated the indications for transthoracic echocardiography and spectrum of cardiac disease found in patients referred to our cardiac unit for echocardiography. Methods: A prospective two-dimensional, pulsed, continuous, and color-flow Doppler echocardiographic evaluation was done using the transthoracic approach in 2501 patients over an eight-year period. Univariate data analysis was performed for mean age, gender, clinical indications, and diagnoses. Results: The subject age range was less than 12 months to 97 years (mean 52.39 years. There were 1352 (54.06% males and 1149 (45.94% females. The most common indication for echocardiography was hypertension (52.1% followed by congestive cardiac failure (13.9%. Others were for screening (6.1%, arrhythmias (5%, cerebrovascular disease (5%, chest pain (3.3%, chronic kidney disease (3.2%, congenital heart disease (2.6%, cardiomyopathy (1.8%, rheumatic heart disease (1.7%, diabetes mellitus (1.3%, thyrocardiac disease (1.2%, ischemic heart

  3. Role of Doppler US and MRI in diagnosis of placenta accreta

    Directory of Open Access Journals (Sweden)

    Manal Hamisa

    2015-09-01

    Conclusion: In conclusion, data of the present study show that the use of transabdominal color Doppler ultrasonography complemented by MRI in suspected cases improves the diagnostic accuracy in prediction of placenta accreta in patients with previous cesarean delivery.

  4. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Masoud Pezeshki Rad

    2015-01-01

    Full Text Available Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56% patients were male subjects and 18 patients (44% were female. Twenty-three (56% patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  5. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    Science.gov (United States)

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  6. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    Science.gov (United States)

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135

  7. Doppler-echocardiographic assessment of valvular regurgitation in healthy young subjects

    International Nuclear Information System (INIS)

    Filcheva, K.; Gochev, D.; Petrovski, P.; Kotsev, P.

    1995-01-01

    The study covers 300 clinically healthy, randomly selected young subjects, aged 17 to 21 years. The incidence and characteristic features of the valvular regurgitations are assayed by means of pulsed and continuous transthoracic Doppler echocardiography. Valvular insufficiency is registered in total of 198 cases (66%). Regurgitation of single valve is observed in 122 cases (61%), regurgitation of two valves - in 70 (36%) and three valves - in six (3%). Right-sided regurgitations (tricuspid, pulmonic and a combination of both) are detected in 156 subjects, and left-sided (mitral and/or aortic) in twenty-six of which only one regurgitation of the aortic valve. There is a definite tendency of the first two to prevail at a ratio 6:1. A constellation of various anatomical and physiological factors are considered as a likely underlying cause. Whenever atrio-ventricular valves are examined (the mitral one in particular), it is necessary that the regurgitation jet involves over 50% of systole in order to avoid hyperdiagnostics and the so-called 'Doppler's disease'. 14 refs., 1 tab., 2 figs. (author)

  8. The differential diagnosis of thyroid solid nodules by colour doppler ultrasound%甲状腺实性结节的彩超鉴别诊断

    Institute of Scientific and Technical Information of China (English)

    于立江; 张颖; 贾齐玉; 陈海霞

    2015-01-01

    目的:探讨彩超在甲状腺结节良恶性鉴别中的应用价值。方法:应用彩超对130例手术治疗的甲状腺结节患者的结节情况进行回顾分析,并与病理结果对比,以得出恶性结节的超声表现。结果:130例(148个结节)中良性结节96个,彩超诊断100个;恶性结节52个,彩超诊断48个。彩超对甲状腺良恶性结节鉴别的灵敏性为89.66%,特异性为97.96%。结论:彩超对甲状腺结节良恶性的鉴别有重要的临床价值。%Objective To evaluate the value of the color Doppler ultrasound in differentiating benign and malignant thyroid nodule. Methods 130 cases of surgical treatment of patients with thyroid nodules were retrospective analysis by the color Doppler ultrasound,and compared with pathological results,to draw the sonographic appearances of the malignant nodules. Results Pathological results of 96 nod-ules were benign in 130 patients(148 nodules),the color Doppler ultrasound examination resule showed 100 with benign nodules;Patho-logical results of 52 nodules were malignant nodules,the color Doppler ultrasound resule for 48 nodules of malignant nodules. The sensitivi-ty,specificity of the color Doppler ultrasound in differentiating benign and malignant thyroid nodule was 89. 66%,97. 96%. Conclusion the color Doppler ultrasound is a valuable method in differentiating benign and malignant thyroid nodule.

  9. Left Ventricular Stroke Volume Quantification by Contrast Echocardiography – Comparison of Linear and Flow-Based Methods to Cardiac Magnetic Resonance

    Science.gov (United States)

    Dele-Michael, Abiola O.; Fujikura, Kana; Devereux, Richard B; Islam, Fahmida; Hriljac, Ingrid; Wilson, Sean R.; Lin, Fay; Weinsaft, Jonathan W.

    2014-01-01

    Background Echocardiography (echo) quantified LV stroke volume (SV) is widely used to assess systolic performance after acute myocardial infarction (AMI). This study compared two common echo approaches – predicated on flow (Doppler) and linear chamber dimensions (Teichholz) – to volumetric SV and global infarct parameters quantified by cardiac magnetic resonance (CMR). Methods Multimodality imaging was performed as part of a post-AMI registry. For echo, SV was measured by Doppler and Teichholz methods. Cine-CMR was used for volumetric SV and LVEF quantification, and delayed-enhancement CMR for infarct size. Results 142 patients underwent same-day echo and CMR. On echo, mean SV by Teichholz (78±17ml) was slightly higher than Doppler (75±16ml; Δ=3±13ml, p=0.02). Compared to SV on CMR (78±18ml), mean difference by Teichholz (Δ=−0.2±14; p=0.89) was slightly smaller than Doppler (Δ−3±14; p=0.02) but limits of agreement were similar between CMR and echo methods (Teichholz: −28, 27 ml, Doppler: −31, 24ml). For Teichholz, differences with CMR SV were greatest among patients with anteroseptal or lateral wall hypokinesis (p<0.05). For Doppler, differences were associated with aortic valve abnormalities or root dilation (p=0.01). SV by both echo methods decreased stepwise in relation to global LV injury as assessed by CMR-quantified LVEF and infarct size (p<0.01). Conclusions Teichholz and Doppler calculated SV yield similar magnitude of agreement with CMR. Teichholz differences with CMR increase with septal or lateral wall contractile dysfunction, whereas Doppler yields increased offsets in patients with aortic remodeling. PMID:23488864

  10. Clinical applications of contrast echocardiography

    International Nuclear Information System (INIS)

    Jorge, Leon Galindo

    2005-01-01

    The echocardiography is the technique more used for the diagnosis and pursuit of the cardiovascular illnesses; therefore, their diagnostic precision has acquired a vital importance in the handling of the patients with cardiovascular pathologies. However, with relative frequency, the diagnostic capacity of the echocardiography exam is diminished by limitations of the acoustic window, mainly in-patient with obesity, lung illnesses and alterations of the thoracic wall. This can be obviated with the use of the intra-esophagus echocardiography, although this it is a procedure semi-invasive and not very practical of carrying out in all the patients with problems of acoustic window. In this article the clinical applications are revised more common of the contrast echocardiography

  11. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  12. Fetal echocardiography

    International Nuclear Information System (INIS)

    Chaubal, Nitin G.; Chaubal, Jyoti

    2009-01-01

    USG performed with a high-end machine, using a good cine-loop facility is extremely helpful in the diagnosis of fetal cardiac anomalies. In fetal echocardiography, the four-chamber view and the outflow-tract view are used to diagnose cardiac anomalies. The most important objective during a targeted anomaly scan is to identify those cases that need a dedicated fetal echocardiogram. Associated truncal and chromosomal anomalies need to be identified. This review shows how fetal echocardiography, apart from identifying structural defects in the fetal heart, can be used to look at rhythm abnormalities and other functional aspects of the fetal heart

  13. Contrast-enhanced power Doppler US in the characterization of renal masses; Power Doppler con mezzo di contrasto nella caratterizzazione delle masse renali

    Energy Technology Data Exchange (ETDEWEB)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E. [Messina Univ., Messina (Italy). Ist. di Scienze Radiologiche

    2000-09-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts. [Italian] Scopo di questo articolo e' quello di riportare i risultati di uno studio prospettico finalizzato ad individuare le potenzialita' del power Doppler con mdc ecografico nella caratterizzazione delle lesioni espansive del rene. Dal 1997 al 30 ottobre 1999 sono state studiate 59 lesioni renali (28 maligne, 31 benigne) in 48 pazienti (eta' media 55 anni, intervallo 10

  14. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    Science.gov (United States)

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  15. Christian Andreas Doppler--the man and his legacy.

    Science.gov (United States)

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  16. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    Science.gov (United States)

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  17. Echocardiography in the Era of Multimodality Cardiovascular Imaging

    Science.gov (United States)

    Shah, Benoy Nalin

    2013-01-01

    Echocardiography remains the most frequently performed cardiac imaging investigation and is an invaluable tool for detailed and accurate evaluation of cardiac structure and function. Echocardiography, nuclear cardiology, cardiac magnetic resonance imaging, and cardiovascular-computed tomography comprise the subspeciality of cardiovascular imaging, and these techniques are often used together for a multimodality, comprehensive assessment of a number of cardiac diseases. This paper provides the general cardiologist and physician with an overview of state-of-the-art modern echocardiography, summarising established indications as well as highlighting advances in stress echocardiography, three-dimensional echocardiography, deformation imaging, and contrast echocardiography. Strengths and limitations of echocardiography are discussed as well as the growing role of real-time three-dimensional echocardiography in the guidance of structural heart interventions in the cardiac catheter laboratory. PMID:23878804

  18. A comparison of cell-free placental messenger ribonucleic acid and color Doppler ultrasound for the prediction of placental invasion in patients with placenta accreta.

    Science.gov (United States)

    Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara

    2015-01-01

    The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.

  19. 65. Impact of focused echocardiography in clinical decision of patients presented with STMI, underwent primary percutenouse angioplasty

    Directory of Open Access Journals (Sweden)

    M. Qasem

    2016-07-01

    Full Text Available Echocardiography in coronary artery diseases is an essential, routine echocardiography prior to primary percutaneous angioplasty is not clear. In our clinical practice in primary angioplasty we faced lots of complications either before or during or after the procedure. Moreover, lots of incidental findings that discovered after the procedure which if known will affect the plan of management. One-hundred-nineteen consecutive underwent primary angioplasty. All patients underwent FE prior to the procedure in catheterization lab while the patient was preparing for the procedure. FE with 2DE of LV at base, mid and apex, and apical stander views. Diastology grading, E/E′ and color doppler of mitral and aortic valve were performed. (N = 119 case of STMI were enrolled, mean age 51 ± 12 year. Eleven cases (9.2% had normal coronary and normal LV function. Twenty cases (17% of MI complication detected before the procedures: RV infarction 8.4% (5.1% asymptomatic and 3.3% symptomatic, ischemic MR (8.4%, LV apical aneurysm (0.8%, significant pericardial effusion (0.80%. Acute pulmonary edema in 17 cases (14.3%: six cases (5.1% developed acute pulmonary edema on the cath lab with grade 3 diastolic dysfunction and E/E ′  >20, 9 cases (7.6% develop acute pulmonary edema in CCU with grade 2–3 diastolic dysfunction and E/E′ 15–20. 2 cases (2.7% develop acute pulmonary in CCU with grade 1–2 diastolic dysfunction and E/E′ 9–14. One case (0.8% presented cardiac tamponade 2 h post PCI. Incidental finding not related to STMI were as follow: 2 cases (1.7% with severe fibro degenerative MR, 2 cases (1.7% with mild to moderate AR and 2 cases (1.7% with mild to moderate AS. Isoled CABG 5/4.2% and CABG and MVR 2/1.7%. FE play an important role in guiding the management, early detection the incidental findings and complication post PCI.

  20. Guideline from Japanese Society of Echocardiography: 2018 focused update incorporated into Guidance for the Management and Maintenance of Echocardiography Equipment.

    Science.gov (United States)

    Daimon, Masao; Akaishi, Makoto; Asanuma, Toshihiko; Hashimoto, Shuji; Izumi, Chisato; Iwanaga, Shiro; Kawai, Hiroya; Toide, Hiroyuki; Hayashida, Akihiro; Yamada, Hirotsugu; Murata, Mitsushige; Hirano, Yutaka; Suzuki, Kengo; Nakatani, Satoshi

    2018-03-01

    Echocardiography plays a pivotal role as an imaging modality in the modern cardiology practice. Information derived from echocardiography is definitely helpful for a patient care. The Japanese Society of Echocardiography has promoted echocardiography for a routine clinical and research use. One of the missions of the Society is to provide information that is useful for high-quality examinations. To ensure it, we believe equipment in good conditions and a comfortable environment are important for both a patient and an examiner. Thus, the Committee for Guideline Writing, the Japanese Society of Echocardiography published brief guidance for the routine use of echocardiography equipment in 2015. Recently, the importance of international standardization has been emphasized in the medical laboratories. Accordingly, the committee has revised and updated our guidance for the routine use of echocardiography equipment.

  1. Tissue Doppler echocardiography improves the diagnosis of coronary artery stenosis in stable angina pectoris

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Jensen, Jan Skov; Iversen, Allan Zeeberg

    2012-01-01

    Aim To determine if colour tissue Doppler imaging (TDI) performed at rest in patients with suspected stable angina pectoris (SAP) is able to predict the presence of significant coronary artery disease (CAD). METHODS AND RESULTS: This study comprises 296 consecutive patients with clinically...... by colour TDI at six mitral annular sites and averaged to provide global estimates. Duke score (DS), including ST depression, chest pain, and exercise capacity, was used as the outcome of the exercise ECG. Patients with an area stenosis of ≥70% in at least one epicardial coronary artery were categorized...

  2. Value of sonomammography utilizing color Doppler technique in qualification of breast cancer patients for sentinel node identification

    International Nuclear Information System (INIS)

    Basta, P.; Wadowska-Jaszczynska, K.; Krysztopowicz, W.; Przybylska, P.; Wisniowski, Z.

    2007-01-01

    Sentinel node identification has become a standard procedure in the management of breast cancer. This procedure requires involvement of a multidisciplinary team and is rather costly. Ultrasonography (USG) of axillary lymph nodes is a method that gives hope for improving the quality of qualification of patients for the procedure. Eighty patients with grade I and II breast cancers underwent sentinel node identification followed by axillary lymphadenectomy. Pre-operative ultrasonography was employed to assess axillary lymph nodes, using the morphological and vascular characteristics as predictors of the presence of lymph node metastases. Sensitivity of sentinel node identification reached 89.3%, specificity - 100%, positive predictive value - 100%, negative predictive value - 93.5%, percentage of false negative results - 10.7%. Sensitivity of USG reached 68.75 %, and specificity - 70.31%. In the group of patients in whom the sentinel node was identified, the sensitivity of the method was 69.23 %, and specificity - 72.41%. Preoperative axillary lymph node ultrasonography in breast cancer patients, utilizing color Doppler technique, allows better selection of patients for sentinel node identification procedure. (author)

  3. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Lavinia Pimentel, E-mail: lavinia.pimentel@globo.com; Camargos, Paulo Augusto Moreira; Torres, Rosália Morais; Meira, Zilda Maria Alves [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2014-08-15

    Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and 16 years. students underwent anamnesis and physical examination with the purpose of establishing criteria for the diagnosis of rheumatic fever. They were all subjected to Doppler echocardiography using a portable machine. Those who exhibited nonphysiological mitral regurgitation (MR) and/or aortic regurgitation (AR) were referred to the Doppler echocardiography laboratory of the Hospital das Clínicas of the Universidade Federal of Minas Gerais (HC-UFMG) to undergo a second Doppler echocardiography examination. According to the findings, the cases of rheumatic heart disease were classified as definitive, probable, or possible. Of the 267 students, 1 (0.37%) had a clinical history compatible with the diagnosis of acute rheumatic fever (ARF) and portable Doppler echocardiography indicated nonphysiological MR and/or AR in 25 (9.4%). Of these, 16 (6%) underwent Doppler echocardiography at HC-UFMG. The results showed definitive rheumatic heart disease in 1 student, probable rheumatic heart disease in 3 students, and possible rheumatic heart disease in 1 student. In the population under study, the prevalence of cases compatible with rheumatic involvement was 5 times higher on Doppler echocardiography (18.7/1000; 95% CI 6.9/1000-41.0/1000) than on clinical evaluation (3.7/1000-95% CI)

  4. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    International Nuclear Information System (INIS)

    Miranda, Lavinia Pimentel; Camargos, Paulo Augusto Moreira; Torres, Rosália Morais; Meira, Zilda Maria Alves

    2014-01-01

    Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and 16 years. students underwent anamnesis and physical examination with the purpose of establishing criteria for the diagnosis of rheumatic fever. They were all subjected to Doppler echocardiography using a portable machine. Those who exhibited nonphysiological mitral regurgitation (MR) and/or aortic regurgitation (AR) were referred to the Doppler echocardiography laboratory of the Hospital das Clínicas of the Universidade Federal of Minas Gerais (HC-UFMG) to undergo a second Doppler echocardiography examination. According to the findings, the cases of rheumatic heart disease were classified as definitive, probable, or possible. Of the 267 students, 1 (0.37%) had a clinical history compatible with the diagnosis of acute rheumatic fever (ARF) and portable Doppler echocardiography indicated nonphysiological MR and/or AR in 25 (9.4%). Of these, 16 (6%) underwent Doppler echocardiography at HC-UFMG. The results showed definitive rheumatic heart disease in 1 student, probable rheumatic heart disease in 3 students, and possible rheumatic heart disease in 1 student. In the population under study, the prevalence of cases compatible with rheumatic involvement was 5 times higher on Doppler echocardiography (18.7/1000; 95% CI 6.9/1000-41.0/1000) than on clinical evaluation (3.7/1000-95% CI)

  5. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity.

  6. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    International Nuclear Information System (INIS)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung

    1997-01-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity

  7. Estimation of diastolic filling pressure with cardiac CT in comparison with echocardiography using tissue doppler imaging: Determination of optimal CT reconstruction parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Sun; Suh, Jon; Lee, Heon [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of); Lee, Bora [Dept. of Biostatistics, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University Hospital Cheonan, Cheonan (Korea, Republic of); Lim, Hyun Kyung [Dept. of Radiology, Soonchunhyang University Hospital Seoul, Seoul (Korea, Republic of)

    2017-08-01

    To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′. Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm{sup 2}). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography. For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.

  8. Transesophageal echocardiography in NeoChord procedure

    Directory of Open Access Journals (Sweden)

    Pittarello Demetrio

    2015-01-01

    Full Text Available Background: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. Methods: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment , for the final tensioning of the chordae and for the final evaluation of the surgical result. Result and Conclusion: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.

  9. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.

  10. Tissue Doppler echocardiography reveals distinct patterns of impaired myocardial velocities in different degrees of coronary artery disease

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Mogelvang, Rasmus; Olsen, Niels Thue

    2010-01-01

    Aim To determine how the left ventricular wall motion assessed by echocardiographic Tissue Doppler Imaging (TDI) is affected by increasing severity of coronary artery disease (CAD) among patients with stable angina pectoris and preserved ejection fraction. METHODS AND RESULTS: This study comprise...

  11. Study of hemodynamics of retroocular vascular by color Doppler ultrasound in diabetes%彩色多普勒超声对糖尿病眼球后血管血流动力学研究

    Institute of Scientific and Technical Information of China (English)

    雷震; 张梅; 李加平; 龙劲松

    2011-01-01

    目的:通过彩色多普勒超声观察糖尿病眼球后血管的血流动力学,研究其诊断价值.方法:共用彩色多普勒超声检查了正常人眼球、糖尿病视网膜病变(diabetic retinopathy,DR)及有糖尿病但无糖尿病视网膜病变(non-diabetic retinopathy,NDR)眼球的球后血管并与荧光素眼底血管造影及检眼镜对比.结果:随着DR的进展,糖尿病患者眼球后血管血流动力学改变的趋势是眼球后动脉的血流速度下降,阻力升高;球后静脉流速增高伴搏动性增强.结论:彩色多普勒超声技术为定量评价DR,判断其预后提供了重要的参考价值.%Objective: To observe the hemodynamic changes of retroocular and evaluate the diagnostic valuation of color Doppler ultraqound in diabetes. Methods: Retroocular hemodynamics were measured in normal and diabetic retinopathy (DR) and non-diabetic retinopathy (NDR) on color Doppler flow imagining and compared with fundus fluorescein angiography (FFA) and Ophthalmoscope. Results: In the progress of DR, the flow's decrease and the resistance's mcrease of retroocular artery were detected in this research, the increase of flow and pulsatility index of retroocular vein were observed too.Conclusion: Color Doppler ultrasound is of important reference value for not only prognosis but also quantitative analysis of diabetic retinopathy.

  12. Right heart function in impaired left ventricular diastolic function: 2D speckle tracking echocardiography-based and Doppler tissue imaging-based analysis of right atrial and ventricular function.

    Science.gov (United States)

    Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk

    2018-01-01

    The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.

  13. Systolic pulmonary artery pressure assessed during routine exercise Doppler echocardiography: insights of a real-world setting in patients with elevated pulmonary pressures.

    Science.gov (United States)

    Korff, Susanne; Enders-Gier, Patricia; Uhlmann, Lorenz; Aurich, Matthias; Greiner, Sebastian; Hirschberg, Kristof; Katus, Hugo A; Mereles, Derliz

    2018-03-19

    Pulmonary hypertension is a marker of disease severity. Exercise Doppler echocardiography (EDE) has proven to be feasible and reliable to assess pulmonary pressure. Increase in systolic pulmonary artery pressure (sPAP) has diagnostic and prognostic value in controlled studies. However, its value when assessed during routine examination in patients with cardiopulmonary diseases and resting sPAP > 35 mmHg is not clearly defined. Clinical documentation and offline reevaluation of digitally stored EDE examinations of patients with appropriate clinical indications for EDE were analyzed. N = 278 patients with sPAP at rest > 35 mmHg met inclusion criteria. One patient was lost to follow-up. Mean age of patients was 72 ± 10 years, 178 (64%) of the study population were men. There were no relevant differences among survivors and non-survivors concerning comorbidities. Exercise performance (3.6 ± 1.2 vs. 4.9 ± 1.4 MET, p  45 mm (HR = 2.58, p  42 mmHg (HR = 1.94, p = 0.010) and ΔsPAP increase ≥ 0.23 mmHg/Watt (HF = 1.92, p = 0.010). After multivariate analysis, NYHA functional class III (HR = 2.35, p < 0.001), LA diameter (HR = 2.28, p = 0.003) and sPAP increase ≥ 0.23 mmHg/Watt (HF = 2.19, p = 0.002) remained significant predictors of mortality, whereas a double product (HR = 0.42, p = 0.005) was associated with better prognosis. sPAP assessment during routine EDE provides relevant prognostic information comparable to findings in studies in selected populations. A higher sPAP increase at lower exercise performance shows significant association with increased of mortality.

  14. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    Directory of Open Access Journals (Sweden)

    Lavinia Pimentel Miranda

    2014-08-01

    Full Text Available Background: Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. Objectives: To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. Methods: This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and 16 years. students underwent anamnesis and physical examination with the purpose of establishing criteria for the diagnosis of rheumatic fever. They were all subjected to Doppler echocardiography using a portable machine. Those who exhibited nonphysiological mitral regurgitation (MR and/or aortic regurgitation (AR were referred to the Doppler echocardiography laboratory of the Hospital das Clínicas of the Universidade Federal of Minas Gerais (HC-UFMG to undergo a second Doppler echocardiography examination. According to the findings, the cases of rheumatic heart disease were classified as definitive, probable, or possible. Results: Of the 267 students, 1 (0.37% had a clinical history compatible with the diagnosis of acute rheumatic fever (ARF and portable Doppler echocardiography indicated nonphysiological MR and/or AR in 25 (9.4%. Of these, 16 (6% underwent Doppler echocardiography at HC-UFMG. The results showed definitive rheumatic heart disease in 1 student, probable rheumatic heart disease in 3 students, and possible rheumatic heart disease in 1 student. Conclusion: In the population under study, the prevalence of cases compatible with rheumatic involvement was 5 times higher on Doppler echocardiography (18.7/1000; 95% CI 6.9/1000-41.0/1000 than on clinical evaluation (3.7/1000-95% CI.

  15. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran's Electronic Health Record (EHR) System.

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-04-01

    Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. to determine the minimum data set of echocardiography reporting system to exchange with Iran's electronic health record (EHR) system. First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients' records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. The highest degree of consensus was found for the following MDSs: patient's name and family name (5), accepting doctor's name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran's electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider.

  16. Transient basilar artery occlusion monitored by transcranial color Doppler presenting with a spectacular shrinking deficit: a case report

    Directory of Open Access Journals (Sweden)

    Del Sette Massimo

    2010-01-01

    Full Text Available Abstract Introduction We describe the case of a 79-year-old Caucasian Italian woman with a transient basilar occlusion monitored by transcranial Doppler, with subsequent recanalization and clinical shrinking deficit. This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. This case is important and needs to be reported because transient basilar occlusion may be easily diagnosed if transcranial Doppler is performed. Case presentation A 79-year-old woman affected by chronic atrial fibrillation and not treated with oral anticoagulants, cardioverted to sinus rhythm during a gastric endoscopy. She then showed a sudden-onset loss of consciousness, horizontal and vertical gaze palsy, tetraparesis and bilateral miosis and coma. Two hours later, the symptoms resolved quickly, leaving no residual neurologic deficits. Transcranial Doppler examination showed a dampened flow in the basilar artery in the emergency examination and a restored flow when the symptoms resolved. Conclusion This is the first case of transient basilar occlusive disease diagnosed and monitored by transcranial Doppler. We believe that transcranial Doppler should be performed in all cases of unexplained acute loss of consciousness, in particular, if associated with signs of brainstem dysfunctions.

  17. A study of the distribution of color Doppler flows in the superficial digital flexor tendon of young Thoroughbreds during their training periods.

    Science.gov (United States)

    Hatazoe, Takashi; Endo, Yoshiro; Iwamoto, Yohei; Korosue, Kenji; Kuroda, Taisuke; Inoue, Saemi; Murata, Daiki; Hobo, Seiji; Misumi, Kazuhiro

    2015-01-01

    Aim of this study was to evaluate the relationships of exercise and tendon injury with Doppler flows appearing in the superficial digital flexor tendon (SDFT) of young Thoroughbreds during training periods. The forelimb SDFTs of 24 one- to two-year-old Thoroughbreds clinically free of any orthopaedic disorders were evaluated using grey-scale (GS) and color Doppler (CD) images during two training periods between December 2013 to April 2015. Twelve horses per year were examined in December, February, and April in training periods that began in September and ended in April. The SDFT was evaluated in 3 longitudinal images of equal lengths (labelled 1, 2, 3 in order from proximal to distal), and 6 transversal images separated by equal lengths (labelled 1A, 1B, 2A, 2B, 3A and 3B in order from proximal to distal) of the metacarpus using both GS and CD. The running (canter and gallop) distance for 1 month before the date of the ultrasonographic examinations was increased in December, February, and April in both of the two training periods. CD flows defined as rhythmically blinking or pulsatory colored signals were found in 56 of 864 (6.4%) transversal CD images, in 28, 12, 13, and 3 images of 1A, 1B, 2A and 2B, respectively, and in 7, 14, and 35 images captured in December, February, and April, respectively. There were no longitudinal or transversal GS images indicating injury in the SDFTs in either of the two training periods. The increase of CD flows in the proximal regions of the SDFT are possibly related to the increase of the running distance during the training periods of the one- to two-year-old Thoroughbreds. Because no injury was diagnosed in the SDFTs by GS images during the training periods, the increase of CD flows in the proximal parts of SDFT is not necessarily predictive of tendon injury in the near future during the training period of young Thoroughbreds.

  18. Retrospective analysis of transthoracic echocardiography about the failure of transcather closure of ventricular septal defect

    International Nuclear Information System (INIS)

    Zhang Yigang; Li Shijie; Liu Ru; Li Zhihong; Fu Qiang

    2008-01-01

    Objective: To evaluate the value of echocardiography in investigation the failure of interventional therapy of VSDs and to increase the successful rate. Methods: 15 cases with failure of VSD closure through interventional approach were undertaken measurement of major parameters of the defect on left ventriculography and then followed by Philips 5500 color Doppler US for repeated multi-direction tangential measuring of the size, morphologic change, relation with peripheral structure and individual valvular regurgitation. Results: (1) Marginal membranous VSD 10 eases; membranance aneurysm 8 cases, ≥ 2 outlets 6 cases. Width of basal part of membranous aneurysm was 8-18 (10±2) mm with depth of 3 10 (6±2) mm, distance from aortic valve was 0-6 (2±1) mm and from tricuspid valve was 2-5 (2±1) mm; associated with slight tricuspid valvular regurgitation. Aortic valvular regurgitation 5 cases showed slight to mild amount and without membranous aneurysm occurred in 2 cases. (2) Intracristal VSD 5 cases showed the size of defect as 6-10 (7±1) mm, with distances of 2-3 (1±0.8) mm from pulmonary valve and 1-2 (1±0.6) mm from aortic valve associated with slight regurgitation in 4 cases, slight tricuspid valvular regurgitation in 5 eases and aortic valvular prolapse in 4 cases. Conclusions: Many factors can influence the direction tangential continuous scanning should be taken for accurate localization and measurement of VSD in order to select the very sight occludor providing high successful rate of occlusion and long term efficacy. (authors)

  19. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  20. Transesophageal echocardiography in patients with cryptogenic cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Dreger Henryk

    2009-03-01

    Full Text Available Abstract Background In about one third of all patients with cerebral ischemia, no definite cause can be identified (cryptogenic stroke. In many patients with initially suspected cryptogenic stroke, however, a cardiogenic etiology can eventually be determined. Hence, the aim of this study was to describe the prevalence of abnormal echocardiographic findings in a large number of these patients. Method Patients with cryptogenic cerebral ischemia (ischemic stroke, IS, and transient ischemic attack, TIA were included. The initial work-up included a neurological examination, EEG, cCT, cMRT, 12-lead ECG, Holter-ECG, Doppler ultrasound of the extracranial arteries, and transthoracic echocardiography. A multiplane transeophageal echocardiography (TEE, including i.v. contrast medium application [Echovist], Valsalva maneuver was performed in all patients Results 702 consecutive patients (380 male, 383 IS, 319 TIA, age 18–90 years were included. In 52.6% of all patients, TEE examination revealed relevant findings. Overall, the most common findings in all patients were: patent foramen ovale (21.7%, previously undiagnosed valvular disease (15.8%, aortic plaques, aortic valve sclerosis, atrial septal aneurysms, regional myocardial dyskinesia, dilated left atrium and atrial septal defects. Older patients (> 55 years, n = 291 and patients with IS had more relevant echocardiographic findings than younger patients or patients with TIA, respectively (p = 0.002, p = 0.003. The prevalence rates of PFO or ASD were higher in younger patients (PFO: 26.8% vs. 18.0%, p = 0.005, ASD: 9.6% vs. 4.9%, p = 0.014. Conclusion A TEE examination in cryptogenic stroke reveals contributing cardiogenic factors in about half of all patients. Younger patients had a higher prevalence of PFO, whereas older patients had more frequently atherosclerotic findings. Therefore, TEE examinations seem indicated in all patients with cryptogenic stroke – irrespective of age – because of

  1. Prediction of wall motion improvement after coronary revascularization in patients with postmyocardial infarction. Diagnostic value of dobutamine stress echocardiography and myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Waku, Sachiko; Ohkubo, Tomoyuki; Takada, Kiyoshi; Ishihara, Tadashi; Ohsawa, Nakaaki; Adachi, Itaru; Narabayashi, Isamu

    1997-01-01

    The diagnostic value of dobutamine stress echocardiography, myocardial contrast echocardiography and dipyridamole stress thallium-201 single photon emission computed tomography (SPECT) for predicting recovery of wall motion abnormality after revascularization was evaluated in 13 patients with postmyocardial infarction. Seventeen segments showed severe wall motion abnormalities before revascularization. Nine segments which had relatively good Tl uptake on delayed SPECT images despite severely abnormal wall motion were opacified during myocardial contrast echocardiography, and showed improved wall motion after revascularization. In contrast, three segments which had poor Tl uptake and severely abnormal wall motion were not opacified during myocardial contrast echocardiography, and showed no improvement in wall motion during dobutamine stress echocardiography and after revascularization. The following three findings were assumed to be signs of myocardial viability: good Tl uptake on delayed SPECT images, improved wall motion by dobutamine stress echocardiography, and positive opacification of the myocardium by myocardiai contrast echocardiography. Myocardial contrast echocardiography had the highest sensitivity (100%) and negative predictive value (100%). Delayed SPECT images had the highest specificity (100%) and positive predictive value (100%). Dobutamine stress echocardiography had a sensitivity of 83.0%, specificity of 80.0%, positive predictive value of 90.9%, and negative predictive value of 66.7%, respectively. Myocardial contrast echocardiography showed the lowest specificity (60.0%). The techniques of dobutamine stress echocardiography and SPECT, though noninvasive, may underestimate wall motion improvement after revascularization. Further examination by myocardial contrast echocardiography is recommended to assess myocardial viability for determining the indications for coronary revascularization in spite of its invasiveness. (author)

  2. Fetal Echocardiography/Your Unborn Baby's Heart

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Fetal Echocardiography / Your Unborn Baby's Heart Updated:Oct 6,2016 ... Your Risk • Symptoms & Diagnosis Introduction Common Tests Fetal Echocardiography/Your Unborn Baby's Heart - Fetal Echocardiogram Test - Detection ...

  3. Idiopathic aneurysm of pulmonary artery

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Julio B. Cota; Pimentel, Patricia N.; Knust, Beatriz S., E-mail: jcota@uol.com.br [Clinica de Cardiologia Cota Pacheco, Mogi das Cruzes, SP (Brazil)

    2015-07-15

    Because it is a very rare isolated lesion, we decided to present this case of idiopathic pulmonary artery aneurysm (IPAA) and review the cases published in the literature in order to correlate our clinical and imaging findings, as well as management based on patient data. IPAA was first described in a case of autopsy by Bristowe in 1860 and later in 1947 by Deterling and Claggett, whose prevalence was lower than eight to one hundred thousand. Although the use of diagnostic imaging methods has been applied in a very large population in recent decades, this lesion has been most often described in postmortem examinations. Therefore, it is important to be aware of possible clinical symptoms, at times non-specific, as well as the signs on imaging studies. In this study, therefore, the report of a case of an asymptomatic patient whose diagnosis was done through color Doppler echocardiography in a routine test in 2012, later confirmed by simple chest computed tomography (chest CT) and cardiac catheterization as IPAA and its branches. We discussed the literature available and the possibilities for treatment and the use of color Doppler echocardiography as an initial diagnostic tool for such a rare and intriguing disease. (author)

  4. Doppler-ultrasonographic finding of air in the portal vein: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1994-03-15

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography.

  5. Doppler-ultrasonographic finding of air in the portal vein: a case report

    International Nuclear Information System (INIS)

    Park, Ki Soon; Lee, Kwan Sup; Lee, Yul; Chung, Soo Young; Bae, Sang Hoon

    1994-01-01

    Classically air in the portal vein has been detected on plain radiography, but computed tomography and ultrasonography have been shown to be more sensitive. We report a case of air in the PV in a 10-day-old infant with pneumatosis intestinalis with its ultrasonographic and Doppler findings. The patient was a 10-day-old infant born by cesarean section at 41 weeks. Simple abdomen film revealed branching pattern of radiolucent air shadows within in contour of liver, gas distention of bowel loops and thickenod bowel walls with lincar intraluminal air shadows in abdomen, suggesting necrotizing enterocolitis. So we performed Doppler ultrasonography. Ultrasonography showed branching pattern of hyperechogenic dots and along the lumen of left portal vein. The color Doppler study revealed an aliasing duo to increased velocity and whirling pattern of blood flow, and the Duplex Doppler spectral display showed sharp, vertical bidirectional spikes by air in portal vein. Air in the portal vein can be easily diagnosed by the following signs: hyperechogenic dots in the portal vein on ultrasonography and vertical, sharp bidirectional spikes superimposed on the usual Doppler tracing of the portal vein on Duplex ultrasonography

  6. Frequency of cardiac defects among children at echocardiography centre in a teaching hospital

    International Nuclear Information System (INIS)

    Malik, A.S.; Majeed, R.; Channer, M.S.; Saleem, M.I.

    2010-01-01

    Objective: To assess frequency of cardiac defects among children from birth to 12 years of age on each Methodology: A cross sectional study was conducted at echocardiography centre in coronary care unit at Bahawal Victoria Hby Paediatric Transthoracic echo probe; 2-D colour Doppler, Acuson CV-70 and Niemo-30 echocardiography machines. Mothers of children with cardiac defects were interviewed at the echocardiography centre. Variables included were A- Muscular plus Vascular defects; B- Valvular defects; C-Pericardial effusion; D- Dextrocardia and E- Congestive cardiac failure. History of children for sore throat followed by joint pains; history of mothers for drug intake (antihypertensive, antipyretic, anti-emetic, hypoglycaemic) as well as chronic diseases (diabetes mellitus, hypertension, anaemia) during pregnancy were surveyed. Parity of mothers, their cousin marriages, and family socio-economic status was also inquired. The results were tabulated, analyzed and finally subjected to suitable test of significant (SR of proportion) to find out statistical significant if any. Results: It was found that out of 150 patients, 76 (50.66%) were suffering from Cardiac muscular and Vascular defects, 61 (40.66%) Valvular defects, 7 (4.66%) Pericardial effusion, 2 (1.33%) Dextrocardia and 4 (2.66%) from Congestive Cardiac Failure. According to age, 54 (36%) were from birth to 3 years of age and 51 (34%) from 10 to 12 years. There was history of Rheumatic fever among 45 (30%) children. There were 106 (70.6%) children from lower socio-economic class and 79 (52.6%) parents had history of cousin marriages. Conclusion: Frequency of cardiac defects was more in children of male sex, lower socio-economic group, from birth to three years age and children from primipara mothers in our specified locality. Rheumatic fever, cousin's marriage, and prescribed drugs intake during pregnancy (for metabolic and hormonal disorders) were other contributors to cardiac defects. (author)

  7. Correlation of Color Doppler with Multidetector CT Angiography Findings in Carotid Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Živorad N. Savic

    2010-01-01

    Full Text Available The aim of this paper was to examine the correlation between the Color Doppler ultrasound (CD-US and multidetector CT angiography (MDCTA diagnostic methods, and to define the degree and extent of stenosis in patients with internal carotid artery stenosis. This was a cross-sectional study with a consecutive series of patients. All US examinations were always carried out by the same physician-angiologist, while all CT examinations were always carried out by the same physician-radiologist. Both worked independently from each other. The stenosis area was measured at the narrowest point by NASCET criteria for US/CT. Peak systolic velocity (PSV over 210 cm/sec and end diastolic velocity (EDV over 110 cm/sec criteria were applied for stenoses with lumen narrowed over 70%, while PSV under 130 cm/sec and EDV under 100 cm/sec criteria were applied for those with lumen narrowed under 70%. A total of 124 carotid arteries were observed; namely, 89 narrowed and 68 surgically treated. All patients were reviewed by US and then by MDCTA; patients with 70–99% stenosis underwent surgery. The correlation coefficient between stenosis degree measured by US and MDCTA was 0.922; p 0.05. The US and CT matching level for stenoses from 70 to 99% was very high (κ = 0.778, p < 0.01. In conclusion, there is a highly significant statistical correlation among both diagnostic methods when measuring stenosis degree and extent. US is more dependent on the physician, while MDCTA is more objective and independent from the physician. We think it would be appropriate to undertake an MDCTA exam for those patients who are candidates for carotid endarterectomy.

  8. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  9. Impact of acquisition and interpretation on total inter-observer variability in echocardiography: results from the quality assurance program of the STAAB cohort study.

    Science.gov (United States)

    Morbach, Caroline; Gelbrich, Götz; Breunig, Margret; Tiffe, Theresa; Wagner, Martin; Heuschmann, Peter U; Störk, Stefan

    2018-02-14

    Variability related to image acquisition and interpretation is an important issue of echocardiography in clinical trials. Nevertheless, there is no broadly accepted standard method for quality assessment of echocardiography in clinical research reports. We present analyses based on the echocardiography quality-assurance program of the ongoing STAAB cohort study (characteristics and course of heart failure stages A-B and determinants of progression). In 43 healthy individuals (mean age 50 ± 14 years; 18 females), duplicate echocardiography scans were acquired and mutually interpreted by one of three trained sonographers and an EACVI certified physician, respectively. Acquisition (AcV), interpretation (InV), and inter-observer variability (IOV; i.e., variability between the acquisition-interpretation sequences of two different observers), were determined for selected M-mode, B-mode, and Doppler parameters. We calculated Bland-Altman upper 95% limits of absolute differences, implying that 95% of measurement differences were smaller/equal to the given value: e.g. LV end-diastolic volume (mL): 25.0, 25.0, 27.9; septal e' velocity (cm/s): 3.03, 1.25, 3.58. Further, 90, 85, and 80% upper limits of absolute differences were determined for the respective parameters. Both, acquisition and interpretation, independently and sizably contributed to IOV. As such, separate assessment of AcV and InV is likely to aid in echocardiography training and quality-assurance. Our results further suggest to routinely determine IOV in clinical trials as a comprehensive measure of imaging quality. The derived 95, 90, 85, and 80% upper limits of absolute differences are suggested as reproducibility targets of future studies, thus contributing to the international efforts of standardization in quality-assurance.

  10. Two-dimensional and Doppler echocardiographic findings in healthy non-sedated red-eared slider terrapins (Trachemys scripta elegans).

    Science.gov (United States)

    Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D

    2011-12-01

    Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.

  11. los soplos cardiacos izquierdos: controversia entre los aspectos clinicos y los ecocardiograficos

    OpenAIRE

    Castaño Valencia, Oscar

    2009-01-01

     By the fact always it has been a cardiologist clinical vocation and have had the privilege of meeting many of the technological advances that currently handle such as hemodynamics, angiography, computed tomography and echocardiography type M, two-dimensional with doppler color, I have had the opportunity to appreciate the contributions of these techniques in the diagnosis of mitral stenosis, mitral insufficiency, aortic stenosis and aortic regurgitation for example. However, I think the Gene...

  12. The Evolutionary Development of Echocardiography

    Science.gov (United States)

    Maleki, Majid; Esmaeilzadeh, Maryam

    2012-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information on cardiac morphology, function, and hemodynamics. It is the most frequently used cardiovascular diagnostic test only after electrocardiography. In less than five decades, the evolution in this technique has made it the basic part of cardiovascular medicine. Herein, the evolution of various forms of echocardiography is briefly described. PMID:23390327

  13. Implementation of the stress echocardiography in an echocardiographic laboratory

    International Nuclear Information System (INIS)

    Solis Brizuela, Felix

    2013-01-01

    The logistics for the implementation of the stress echocardiography is defined with based on current recommendations, for an echocardiography laboratory. The protocols established to perform the studies and procedures of this diagnostic method are exposed. The elementary conditions to realize with safety the stress echocardiography are established. Recent literature on the evaluation of new echocardiographic techniques is reviewed to determine their usefulness in stress testing. The assessment of stress echocardiography is developed. The stress echocardiography has been the procedure with high sensitivity and specificity for the diagnosis of coronary artery disease [es

  14. Transvaginal color Doppler imaging of uterine contractions in early pregnancies: Significance of uterine contractions in early pregnancy failure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ju; Han, Chang Jin; Suh, Jung Ho; Kwon, Hyuck Chan [Aju University SChool of Medicine, Suwon (Korea, Republic of)

    1999-06-15

    To assess uterine contractions in early pregnancies using transvaginal color Doppler sonography (TVCDS) and to determine the role of uterine contractions in the diagnosis of early pregnancy failure. 76 patients with abnormal pregnancy diagnosed by sonography or histopathology up to 10 weeks of gestation and 38 normal pregnant women as the control group were examines with TVCDS. The presence of uterine contractions was determined by complete or partial disappearance of the color flow signals of vessels within myometrium, and the direction, amplitude (grade 1-3), and interval of uterine contractions were also evaluated. Uterine contractions were identified in 42 (55.3%) of 76 patients with abnormal pregnancy, whereas they were detected only in 2 (5.3%) of 38 normal pregnant women who had initial grade 1 contraction but disappeared in the follow-up study. In 26 patients with blighted ovum or missed abortion, 15 patients (57.7%),showed uterine contraction of grade 1 in 3 cases, grade 2 in 8 cases, and grade 3 in 4 cases and interval from 45 seconds to 5 minutes. In 30 patients with inevitable or incomplete abortion, 23 patients (76.6%) showed uterine contraction of grade 1 in 2 cases, grade 2 in 9 cases, and grade 3 in 12 cases and interval from 1 to 5 minutes. 4 (20%) of 20 patients with threatened abortion had uterine contraction of grade 2 and interval from 2 to 4 minutes. The presence of uterine contractions was significantly different in abnormal pregnancies compared with that of normal and also among the tree different groups of abnormal pregnancies, but the amplitude did not differ.

  15. Transvaginal color Doppler imaging of uterine contractions in early pregnancies: Significance of uterine contractions in early pregnancy failure

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Han, Chang Jin; Suh, Jung Ho; Kwon, Hyuck Chan

    1999-01-01

    To assess uterine contractions in early pregnancies using transvaginal color Doppler sonography (TVCDS) and to determine the role of uterine contractions in the diagnosis of early pregnancy failure. 76 patients with abnormal pregnancy diagnosed by sonography or histopathology up to 10 weeks of gestation and 38 normal pregnant women as the control group were examines with TVCDS. The presence of uterine contractions was determined by complete or partial disappearance of the color flow signals of vessels within myometrium, and the direction, amplitude (grade 1-3), and interval of uterine contractions were also evaluated. Uterine contractions were identified in 42 (55.3%) of 76 patients with abnormal pregnancy, whereas they were detected only in 2 (5.3%) of 38 normal pregnant women who had initial grade 1 contraction but disappeared in the follow-up study. In 26 patients with blighted ovum or missed abortion, 15 patients (57.7%),showed uterine contraction of grade 1 in 3 cases, grade 2 in 8 cases, and grade 3 in 4 cases and interval from 45 seconds to 5 minutes. In 30 patients with inevitable or incomplete abortion, 23 patients (76.6%) showed uterine contraction of grade 1 in 2 cases, grade 2 in 9 cases, and grade 3 in 12 cases and interval from 1 to 5 minutes. 4 (20%) of 20 patients with threatened abortion had uterine contraction of grade 2 and interval from 2 to 4 minutes. The presence of uterine contractions was significantly different in abnormal pregnancies compared with that of normal and also among the tree different groups of abnormal pregnancies, but the amplitude did not differ.

  16. Transesophageal echocardiography. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lambertz, Heinz; Lethen, Harald

    2013-01-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  17. Evaluation of left ventricular function in obese children without hypertension by a tissue Doppler imaging study.

    Science.gov (United States)

    Ghandi, Yazdan; Sharifi, Mehrzad; Habibi, Danial; Dorreh, Fatemeh; Hashemi, Mojtaba

    2018-01-01

    The prevalence of obesity is increasing worldwide. Obese children without hypertension are becoming an important health challenge. Complications of obesity in adults are well established, but in obese children, cardiac dysfunction has not been reported clinically. The present crosssectional study investigates subclinical systolic and diastolic dysfunction using echocardiographic modalities. Twentyfive youngsters with body mass index (BMI) >30 and 25 healthy children with BMI <25 were assigned into case and control group, respectively. In all participants, complete cardiovascular examination, electrocardiography, and echocardiography were fulfilled. Echocardiography surveys included standard, pulsed wave Doppler (PWD), and tissue Doppler imaging (TDI). SPSS software, version 24. The two groups were matched for age and sex. The resting heart rate and blood pressure were markedly higher in the obese group ( P = 0.0001) though they were within the normal range in either category. Ejection fraction in the two groups was similar. Left ventricular (LV) mass ( P = 0.0001), LV mass index ( P = 0.029), left atrialtoaortic diameter ratio ( P = 0.0001), and LV enddiastolic diameter ( P = 0.008) were significantly greater in the case group, indicating cardiomegaly and subclinical systolic and diastolic dysfunction. Except for the aortic velocity, all PWD variables were considerably lower in the case group, suggesting subclinical diastolic dysfunction. All TDI parameters varied significantly between the two categories. There was a direct correlation between isovolumetric relaxation time and BMI. Obesity in children without hypertension is associated with subclinical systolic and diastolic cardiac dysfunction. We propose the evaluation of blood pressure as well as myocardial performance using PWD and TDI in all obese children without hypertension, regularly.

  18. Avaliação do bem-estar fetal pela dopplervelocimetria com mapeamento em cores Evaluation of fetal well-being through color doppler velocimetry

    Directory of Open Access Journals (Sweden)

    Cleide Mara Mazzotti de Oliveira Franzin

    1999-01-01

    aorta, and the adverse perinatal results was established. The pregnant women selected for this study were submitted electively to cesarean sections, at the utmost four hours after the color Doppler examination. We considered as adverse perinatal results: Apgar score lower than seven at the 5th minute, neonatal intensive care unit hospitalization, intrauterine growth retardation, acute fetal distress, perinatal mortality, hypoglycemia, polycythemia, necrotizing enterocolitis, and cerebral hemorrhage. The indexes for the umbilical and middle cerebral arteries and the abdominal aorta were related, in each case, to the adverse perinatal results. Results: the systole/diastole umbilical artery ratio presented a higher sensitivity than the pulsatile and tolerance indexes. The Doppler study of the umbilical artery presented greater sensitivity than the middle cerebral artery and the abdominal aorta in detecting adverse perinatal results. Conclusion: the Doppler velocimetry of the umbilical and middle cerebral arteries presented good diagnostic capacity in evaluating fetal well-being, and a significant association with the adverse perinatal results.

  19. Practical guidance for the implementation of stress echocardiography.

    Science.gov (United States)

    Suzuki, Kengo; Hirano, Yutaka; Yamada, Hirotsugu; Murata, Mitsushige; Daimon, Masao; Takeuchi, Masaaki; Seo, Yoshihiro; Izumi, Chisato; Akaishi, Makoto

    2018-06-06

    Exercise stress testing has been widely undertaken for the diagnosis of heart diseases. The accurate assessment of clinical conditions can be conducted by comparing the findings obtained from the results of stress echocardiography with the changes in the blood/heart rate and electrocardiograms. Numerous overseas studies have reported the utility of stress echocardiography in diagnosing myocardial ischemia; in Japan, the use of this modality for this purpose was included in the national health insurance reimbursable list in 2012. Nevertheless, stress echocardiography is far from being a widespread practice in Japan. This might be due to insufficient equipment (e.g., ergometers, space for test implementation) at each medical institution, shortage of technicians and sonographers who are well experienced and who are responsible for obtaining images during stress testing. The other possible reasons include the limited evidence available in Japan and the lack of a standardized testing protocol. Further dissemination of the practice of exercise stress echocardiography in this country is deemed necessary to establish satisfactory evidence for the use of stress echocardiography in the Japanese population. To this end, efforts are underway to develop a standardized protocol and report format to be adopted throughout Japan. We here present a guideline created by the Guideline Development Committee of the Japanese Society of Echocardiography that describes safe and effective stress echocardiography protocols and report formats. The readers are encouraged to perform exercise stress echocardiography using the proposed template for consensus document and report attached to this guideline.

  20. Archeological Echocardiography: Digitization and Speckle Tracking Analysis of Archival Echocardiograms in the HyperGEN Study.

    Science.gov (United States)

    Aguilar, Frank G; Selvaraj, Senthil; Martinez, Eva E; Katz, Daniel H; Beussink, Lauren; Kim, Kwang-Youn A; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R; Arnett, Donna K; Shah, Sanjiv J

    2016-03-01

    Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. In the NHLBI HyperGEN study (N = 2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter-/intra-observer agreement was calculated. Accuracy was evaluated in: (1) a separate second study (N = 50) comparing prospective digital strain versus post hoc analog-to-digital strain, and (2) in a third study (N = 95) comparing prospectively obtained TDI e' velocities with post hoc STE e' velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intra-observer agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post hoc STE to prospective digital STE for strain analysis. STE-derived e' velocities correlated with, but systematically underestimated, TDI e' velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β = -2.4 [95% CI -3.6, -1.2]% per 1-SD increase in fasting glucose; P echocardiography, the digitization and speckle tracking analysis of archival echocardiograms, is feasible and generates indices of cardiac mechanics similar to contemporary studies. © 2015, Wiley Periodicals, Inc.

  1. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  2. Carcinoid syndrome diagnosed by echocardiography.

    Science.gov (United States)

    Garg, Scot; Bourantas, Christos V; Nair, Rajesh K; Alamgir, Farqad

    2011-02-17

    Right heart failure is a common presentation to both general physicians and cardiologists. Echocardiography is a useful investigation, and usually imaging of the liver is confined to helping estimate the right atrial pressure. We report a case of right heart failure where incidental imaging of the liver architecture during transoesophageal echocardiography helped in establishing the final diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Early Detection of Subclinical Uremic Cardiomyopathy Using Two-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Hassanin, Noha; Alkemary, Alkhateeb

    2016-04-01

    Overhydration has a deleterious effect on cardio myocytes. This study was designated to evaluate left ventricular (LV) systolic and diastolic dysfunction in patients with various stages of chronic kidney disease (CKD) using conventional, tissue Doppler and two-dimensional speckle tracking echocardiography (2DSTE). Forty controls and 90 CKD patients, aged 49.3 ± 14 years old, were enrolled in the study. Patients were divided into 3 groups depending on their glomerular filtration rate. Group 1 (≥60 mL/min per 1.73 m(2) ), group 2 (≤60 mL/min per 1.73 m(2) ), and group 3 (≤60 mL/min per 1.73 m(2) and on regular dialysis for at least 12 months). Pulsed-Doppler and tissue Doppler studies were used to estimate LV filling pressure E/E'. Using 2DSTE, circumferential, radial, and longitudinal functions of the LV have been measured. LV longitudinal systolic strain, early, and late diastolic strain rates were significantly reduced in CKD patients (-16.9 ± 3.8%, 1.6 ± 0.5%, and 1.3 ± 0.4% in CKD vs. -22.5 ± 0.6%, 2.3 ± 0.2%, and 1.9 ± 0.1% in controls, P < 0.001 for all), and no difference was observed in terms of the circumferential LV functions (-22.4 ± 1.7 vs. -22.5 ± 1.4, P = 0.567). Severity of the kidney dysfunction appears to parallel with the rise of E/E' significantly (P < 0.001). In CKD, although the longitudinal and radial systolic functions were reduced, LV ejection fraction may remain within normal limits due to the preservation of the circumferential functions. Early detection of uremic cardiomyopathy might provide useful information for the risk stratification and decide the proper dialysis therapy in these patients. © 2015, Wiley Periodicals, Inc.

  4. Application of Color Doppler Ultrasound in Renal Medullary Calcium%彩色多普勒超声在肾髓质钙质沉着症中的应用分析

    Institute of Scientific and Technical Information of China (English)

    金丽梅

    2016-01-01

    目的:分析彩色多普勒超声在肾髓质钙沉着症中的应用价值。方法回顾性分析2011—2015年期间在该院行彩色多普勒超声诊断肾髓质钙沉着症的68例患者的临床资料,观察患者的超声诊断特点以及血流动力学改变。结果68例行彩色多普勒超声诊断肾髓质钙沉着症的患者中,诊断阳性共65例,阴性3例,诊断的准确率为95.6%,65例肾髓质钙沉着症患者中包括皮质型30例,髓质型32例,混合型3例,患者的两侧肾脏大小正常,形态对称,包膜光滑,皮质和髓质界限较为清楚,肾脏的皮质厚度和回声均正常,在患者的髓质内,有密集点状的强回声,形态和椎体的形态基本一致,有一侧有弱声影。结论彩色多普勒超声在肾髓质钙沉着症中应用,准确率较高,可以有效的显示内部的形态、血流变化等指标,具有重要的临床诊断价值。%Objective To analyze the value of color Doppler ultrasound in the renal medulla of calcium applications. Methods Convenient selection a retrospective analysis of clinical data by color Doppler ultrasound diagnosis of renal medullary calcinosis disease 68 patients were retrospectively analyzed the period from 2011 to 2015, observed in patients with ultrasonic diagnostic characteristics and hemodynamic change. Results 68 patients with routine color Doppler ultra-sound diagnosis of renal medullary calcinosis disease, the diagnosis of a total of65 positive cases, negative in 3 cases, the diagnostic accuracy was 95.6%, 65 cases of renal medullary calcinosis patients included cortical 30 cases, 32 cases of medullary, mixed three cases, both sides of the patient's normal kidney size, shape symmetry, smooth coated, cortex and medulla boundaries more clearly, renal cortical thickness and echo were normal in patients within the medulla, a strong e-cho dense point-like, form and shape of the vertebral body are basically the same, there is one

  5. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran’s Electronic Health Record (EHR) System

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-01-01

    Background: Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. Aim: to determine the minimum data set of echocardiography reporting system to exchange with Iran’s electronic health record (EHR) system. Methods: First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients’ records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. Results: The highest degree of consensus was found for the following MDSs: patient’s name and family name (5), accepting doctor’s name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. Conclusions: To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran’s electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider. PMID:27147803

  6. Recent advances in echocardiography for valvular heart disease.

    Science.gov (United States)

    Hahn, Rebecca

    2015-01-01

    Echocardiography is the imaging modality of choice for the assessment of patients with valvular heart disease. Echocardiographic advancements may have particular impact on the assessment and management of patients with valvular heart disease. This review will summarize the current literature on advancements, such as three-dimensional echocardiography, strain imaging, intracardiac echocardiography, and fusion imaging, in this patient population.

  7. [Parenchymal complications of the transplanted kidney: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Clementi, Silvia; Clementi, Anna; Di Pietro, Fabio; Scarfia, Viviana R; Insalaco, Monica; Aucella, Filippo; Prencipe, Michele; Fiorini, Fulvio; Sicurezza, Elvia

    2012-01-01

    Kidney transplantation is the treatment of choice for end-stage renal disease, given the better quality of life of transplanted patients when compared to patients on maintenance dialysis. In spite of surgical improvements and new immunosuppressive regimens, part of the transplanted grafts still develop chronic dysfunction. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of vascular and surgical complications of the transplanted kidney, its role is not fully understood in case of parenchymal complications of the graft. The specificity of Doppler ultrasound is low both in case of acute complications such as acute tubular necrosis, drug toxicity and acute rejection, and in case of chronic conditions such as chronic allograft nephropathy. Single determinations of resistance indices present low diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including tissue pulsatility index, maximal fractional area and contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of parenchymal complications of the transplanted kidney.

  8. Multiple cardiac complications after adjuvant therapy for breast cancer: the importance of echocardiography. A case report and review of the literature.

    Science.gov (United States)

    Gurghean, Adriana Luminita; Savulescu-Fiedler, Ilinca; Mihailescu, Anca

    2017-01-31

    Cardiovascular complications induced by adjuvant cancer therapies may become symptomatic after many years, being responsible for increased morbidity and mortality in long-term survivors. We report a case of a 54-year old female admitted for severe heart failure induced by myocardial and valvular damage after postoperative adjuvant therapy for left breast cancer 6 years ago. Her recent history revealed nonST elevation myocardial infarction in the absence of significant cardiovascular risk factors. Transthoracic echocardiography, tissue Doppler imaging and speckle-tracking imaging revealed severe biventricular systolic dysfunction, severe mitral and tricuspid regurgitation and severe pulmonary hypertension.

  9. SELECTIVE AND NONSELECTIVE β-BLOCKERS IN PRIMARY OPEN ANGLE GLAUCOMA THERAPY – RESULTS OF COLOR DOPPLER SONOGRAPHY

    Directory of Open Access Journals (Sweden)

    Vukoslava Maričić-Došen

    2002-12-01

    Full Text Available Background. Primary open angle glaucoma (POAG is a syndrome of progressive optic neuropathy characterized by optic nerve head excavation and visual field defects. Poor correlation between IOP and progression of glaucoma disease sets vascular mechanism in the centre of attention. By Color Doppler sonography, quantification of blood flow changes in vessels, which supply optic nerve head, is possible. We wanted to find out whether there are changes in the circulation of central retinal artery and posterior ciliary arteries in patients with primary open angle glaucoma treated with selective or nonselective β -blockers.Methods. 44 patients (88 eyes were divided into two groups: group 1: 22 patients (44 eyes treated with selective β -blockers (Betaxolol 0.5% and group 2: 22 patients (44 eyes treated with nonselective β -blockers (Timolol 0.5%. Vascular indices (RI, PI were measured in the central retinal artery and posterior ciliary arteries.Results. We found decreased blood flow and increased vascular indices in both groups of patients, statistically significant difference between group 1 and group 2: blood flow velocity was higher and vascular indices were lower in group 1 (Betaxolol 0.5% compared to group 2 (Timolol 0..5%.Conclusions. Selective β -blockers (calcium channel blockers act more vasoactively and neuroprotectively comparing to nonselective β -blockers.

  10. Deep vein thrombosis of the lower limbs: A retrospective analysis of doppler ultrasound findings

    Directory of Open Access Journals (Sweden)

    Sanjay M Khaladkar

    2014-01-01

    Full Text Available Background: Deep venous thrombosis (DVT of lower limbs is one of the most common cause for the majority of deaths caused by pulmonary embolism. Many medical and surgical disorders are complicated by DVT. Most venous thrombi are clinically silent. B-mode and color Doppler imaging is needed for early diagnosis of DVT to prevent complications and sequalae of DVT. Aim and Objectives: The objectives of the following study were to evaluate the role of Doppler as an imaging modality in diagnosing DVT of lower limbs, to study the spectrum of findings on Doppler ultrasound in patients with DVT. Materials and Methods: Retrospective descriptive analysis of 78 patients of DVT diagnosed on Doppler. Results: Nearly 74% of the patients were males and 26% were females with majority belonging to fifth decade (26%. 75 (96.1% cases showed unilateral while 3 (3.9% cases showed bilateral lower limb involvement. In our study, predominant distribution of thrombus was found to be in above knee region with 69/78 (88.5% patients having thrombus in the superficial femoral vein. Popliteal vein was involved in 54/78 (69.2% patients. Complete thrombosis was observed in 54/78 (69% cases, while partial thrombosis was observed in 24/78 (31% cases. Subacute stage was seen in 42 cases (53.8%, acute stage in 23 cases (29.5% while chronic stage in 13 cases (16.7%. 71 cases (91% had multiple contiguous segmental involvement, whereas 7 cases (9% had isolated vein involvement. Conclusion: Color Doppler is useful in diagnosing DVT in symptomatic and at risk patients and provides a non-invasive method of investigation. It is also helpful in evaluating the site, extent and stage of thrombus.

  11. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  12. Fetal Echocardiography and Indications

    Directory of Open Access Journals (Sweden)

    Melih Atahan Güven

    2008-09-01

    Full Text Available Congenital heart diseases are encountered in 0.8% of live births and are among the most frequently diagnosed malformations. At least half of these anomalies end up with death or require surgical interventions and are responsible for 30% of the perinatal mortality. Fetal echocardiography is the sum of knowledge, skill and orientation rather than knowing the embryologic details of the fetal heart. The purpose of fetal echocardiography is to document the presence of normal fetal cardiac anatomy and rhythm in high risk group and to define the anomaly and arrhythmia if present. A certain sequence should be followed during the evaluation of fetal heart. Sequential segmental analysis (SSA and basic definition terminology made it possible to determine a lot of complex cardiac anomalies during prenatal period. By the end of 1970’s, Shinebourne started using sequential segmental analysis for fetal cardiac evaluation and today, prenatal diagnosis of congenital heart disease is possible without any confusion. In this manner, whole fetal heart can be evaluated as the relation of three segments (atria, ventricles and the great arteries with each other, irrelevant of complexity of a possible cardiac anomaly. Presence of increased nuchal thickness during early gestation and abnormal four-chamber-view during ultrasonography by the obstetrician presents a clear indication for fetal echocardiography,however, one should keep in mind that 80-90% of the babies born with a congenital heart disease do not have a familial or maternal risk factor. In addition, it should be remembered that expectant mothers with diabetes mellitus pose an indication for fetal echocardiography.

  13. Endocarditis : Effects of routine echocardiography during Gram-positive bacteraemia

    NARCIS (Netherlands)

    Vos, F J; Bleeker-Rovers, C P; Sturm, P D; Krabbe, P F M; van Dijk, A P J; Oyen, W J G; Kullberg, B J

    2011-01-01

    BACKGROUND: Despite firm recommendations to perform echocardiography in high-risk patients with Gram-positive bacteraemia, routine echocardiography is not embedded in daily practice in many settings. The aim of this study was to evaluate whether a regime including routine echocardiography results in

  14. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  15. The clinical study of 2D and power doppler ultrasound in esophagus varix

    International Nuclear Information System (INIS)

    Li Qiang; Zhou Liang; Zhang Yucheng; Yang Minghua; Ruan Fenglian; Lu Haixia; Li Yue

    2008-01-01

    Objective: To study the application of 2D and Power Doppler Ultrasound in diagnosing the abdominal esophageal varicose veins. Methods: 65 patients under suspicion with chronic hepatitis and cirrhosis for esophageal varicose at esophagus in abdomen section were examined by 2D and Power Doppler Ultrasound.Among them, 35 patients suffered from esophageal varicose veins proved by gastroscopy and the rest did not. Results: On the power doppler imaging map, colored blood stream signals were showed in varicose veins while without signals in non-varicose veins.The diagnostic sensitivity and specificity were 91.4% and 100% respectively. On the two-dimensional image chart, non-echoes were represented in varicose veins. The anteroposterior diameter, right-left diameter, as well as the thickness of esophagus wall were larger in patients with varicose veins than those in non varicose veins cases (P<0.01). Conclusion: 2D combined with Power Doppler Ultrasound was of non-invasive, safe, sensitive and high specificity, which is a valuable and practical tool in diagnosing the esophageal varicose veins. (authors)

  16. Diastolic left ventricular function in preterm infants with a patent ductus arteriosus: a serial Doppler echocardiography study.

    Science.gov (United States)

    Schmitz, Lothar; Stiller, Brigitte; Koch, Heike; Koehne, Petra; Lange, Peter

    2004-02-01

    In very low birth weight neonates, a left-to-right shunt via persistent ductus arteriosus (PDA) may interact with diastolic left ventricular function, but specific changes of Doppler parameters have yet to be reported. In a serial transmitral Doppler study, we investigated the impact of a PDA on diastolic function parameters. Twenty-two patients with and without PDA were examined on day 3.8+/-1 and day 14+/-2 after birth. By the first examination, 13 out of 22 patients had a PDA; by the second examination, the number was still 8 out of 22. Peak early and atrial flow velocities (44.8+/-15 and 50.1+/-13 cm/s, respectively) were higher (pclosure of the PDA. When premature infants with a PDA experience a preload challenge, early and atrial peak velocities increase and IVRT shortens significantly. This coincidence of elevated transvalvular pressure differences and decreased IVRT in neonates with immature diastolic function can best be explained as a result of left atrial pressure elevation. Consequently, pulmonary venous pressure must be elevated, with its inherent effect on pulmonary capillary physiology. Thus, the monitoring of left ventricular diastolic function adds significant information to the care of preterm infants with a PDA.

  17. Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.

    Science.gov (United States)

    Samad, Zainab; Minter, Stephanie; Armour, Alicia; Tinnemore, Amanda; Sivak, Joseph A; Sedberry, Brenda; Strub, Karen; Horan, Seanna M; Harrison, J Kevin; Kisslo, Joseph; Douglas, Pamela S; Velazquez, Eric J

    2016-03-01

    The management of aortic stenosis rests on accurate echocardiographic diagnosis. Hence, it was chosen as a test case to examine the utility of continuous quality improvement (CQI) approaches to increase echocardiographic data accuracy and reliability. A novel, multistep CQI program was designed and prospectively used to investigate whether it could minimize the difference in aortic valve mean gradients reported by echocardiography when compared with cardiac catheterization. The Duke Echo Laboratory compiled a multidisciplinary CQI team including 4 senior sonographers and MD faculty to develop a mapped CQI process that incorporated Intersocietal Accreditation Commission standards. Quarterly, the CQI team reviewed all moderate- or greater-severity aortic stenosis echocardiography studies with concomitant catheterization data, and deidentified individual and group results were shared at meetings attended by cardiologists and sonographers. After review of 2011 data, the CQI team proposed specific amendments implemented over 2012: the use of nontraditional imaging and Doppler windows as well as evaluation of aortic gradients by a second sonographer. The primary outcome measure was agreement between catheterization- and echocardiography-derived mean gradients calculated by using the coverage probability index with a prespecified acceptable echocardiography-catheterization difference of <10 mm Hg in mean gradient. Between January 2011 and January 2014, 2093 echocardiograms reported moderate or greater aortic stenosis. Among cases with available catheterization data pre- and post-CQI, the coverage probability index increased from 54% to 70% (P=0.03; 98 cases, year 2011; 70 cases, year 2013). The proportion of patients referred for invasive valve hemodynamics decreased from 47% pre-CQI to 19% post-CQI (P<0.001). A laboratory practice pattern that was amenable to reform was identified, and a multistep modification was designed and implemented that produced clinically

  18. What every radiologist should know about paediatric echocardiography

    International Nuclear Information System (INIS)

    Sorantin, Erich; Heinzl, Bernd

    2014-01-01

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized

  19. What every radiologist should know about paediatric echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Sorantin, Erich, E-mail: erich.sorantin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria); Heinzl, Bernd [Division of Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria)

    2014-09-15

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized.

  20. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  1. Echocardiography and cardiac resynchronisation therapy, friends or foes?

    Science.gov (United States)

    van Everdingen, W M; Schipper, J C; van 't Sant, J; Ramdat Misier, K; Meine, M; Cramer, M J

    2016-01-01

    Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

  2. Diagnostic value of echocardiography in infective endocarditis

    International Nuclear Information System (INIS)

    Luo Yinli; Ni Xianda; Hu Yuanping; Liu Jingyun; Yang Weiyu

    2010-01-01

    Objective: To investigate the feature and value of echocardiography for diagnosing infective endocarditis. Methods: The shape, size, echogenicity, distribution of vegetations and valvular injury of the heart were observed in 30 patients with infective endocarditis. Results: The vegetations were located in the aortic valves (10 cases), bicuspid valves (5), tricuspid valve (1), pulmonary valve (2), main pulmonary artery with patent ductus arteriosus (2), and right ventricle with ventricular septal defect (2). The size of vegetation ranged from 2 to 27 mm and the echogenicity of vegetations was low to high. The location, size, shape and amount of vegetations observed on echocardiography correlated well with the operative findings. Echocardiography also demonstrated underlying heart disease and abnormal hemodynamics induced by infective endocarditis. Conclusion: Echocardiography can determine the location, size, shape, amount of vegetation and concomitant cardiac disease in patients with infective endocarditis. It play an important role in treatment and prognosis. (authors)

  3. High-resolution color Doppler ultrasonographic characteritics of lymphatic malformations%淋巴管畸形的高频超声与彩色多普勒特点

    Institute of Scientific and Technical Information of China (English)

    张梅; 谷凌云; 李宪坤; 许雅琴; 郝岩

    2012-01-01

    目的 研究淋巴管畸形的高频超声及彩色多普勒超声表现特点并进行分析、总结.方法 应用高频超声及彩色多普勒超声对23例淋巴管畸形的二维灰阶超声声像图及彩色血流信号进行回顾性研究.超声扫查内容包括:病变大小、边界、内部回声、彩色血流信号及用脉冲多普勒测量血流速度.结果 17例淋巴管畸形(74%,17/23)位于颈部、颌下或腋下,6例位于其他部位;21例位于皮下组织内,其中3例同时累及真皮及肌层.13例大囊型淋巴管畸型,均显示为较大的无回声区,有分隔,壁光滑,其中2例大囊型合并感染,无回声区内有稀疏低回声;5例混合型淋巴管畸形,为淋巴管畸形和血管畸形混合存在,超声显示为大小不等的无回声区有分隔,合并局部微小无回声区或不规则的小的实性低回声区,其中3例侵及肌层;5例微囊型淋巴管畸形,超声显示以无回声区为主,内有少量的低回声区,形成囊实混合性病变.所有病例无回声区内彩色多普勒扫查均无彩色血流信号.8例大囊型及3例混合型淋巴管畸形周边扫查到彩色血流信号,2例微囊型内部实性低回声内显示有彩色血流信号.脉冲多普勒检查最大血流速度18~73 cm/s,阻力指数0.55~0.72.结论 淋巴管畸形的高频超声及彩色超声多普勒成像有显著的特点,以较大的无回声区为主,多发可有分隔,无回声区内无血流信号,大部分位于皮下组织内,基于以上特点,可确诊大部分病例,因而高频超声及彩色多普勒是诊断淋巴管畸形的较好方法.%Objective To analyse the characteristics and diagnostic value of high resolution grayscale and color Doppler ultrasound in lymphatic malformations . Methods Twenty-three lymphatic malformations were evaluated by 7-12 MHz high-resolution grayscale and color Doppler ultrasound . All the cases were comfirmed by histopathologic diagnosis . The size, location, margin, echo

  4. Truncus arteriosus communis in a midtrimester fetus: Comparison of prenatal ultrasound and MRI with postmortem MRI and autopsy

    International Nuclear Information System (INIS)

    Muehler, Matthias R.; Lembcke, Alexander; Fischer, Thomas; Kivelitz, Dietmar; Rake, Anett; Chaoui, Rabih; Heling, Kay-Sven; Schwabe, Michael; Planke, Christiane

    2004-01-01

    Different techniques are used in fetal cardiology, and their accuracy has been demonstrated on several occasions. Color Doppler US has proved to be a reliable and valuable tool in the diagnosis of fetal cardiac abnormalities. Magnetic resonance imaging (MRI) of the fetal heart has, so far, played no role in prenatal diagnostics. We report on a truncus arteriosus communis diagnosed prenatally during a screening ultrasound at 22 weeks of gestation. In addition to real-time ultrasound and color Doppler echocardiography, fetal MRI was performed. Fetal echocardiography arose suspicion of a type I common trunk. Fetal MR showed solely a widened vessel coursing retrocardially and additionally an inhomogeneous fluid distribution of the lung not shown on prenatal US. After termination of pregnancy at 23 weeks of gestation, MR fetography and autopsy were performed, and both found a type II common trunk. MR autopsy of the heart was very reliable in this case and could be an alternative when fetal pathology is not available for different reasons. Postmortem MRI was also able to demonstrate the inhomogeneous fluid distribution in the lung, which was confirmed by autopsy. Fetal and postmortem MR was reliable in the detection of an inhomogeneous fluid distribution in the lung not shown on prenatal US, providing a relevant additional finding to US. Therefore, MRI should be used more often in fetal cardiology, although it still must be further developed. (orig.)

  5. Echocardiography as an indication of continuous-time cardiac quiescence

    Science.gov (United States)

    Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.

    2016-07-01

    Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a

  6. Clinical Stress Echocardiography

    NARCIS (Netherlands)

    S.E. Karagiannis

    2007-01-01

    textabstractTwo-dimensional echocardiography is a commonly used non-invasive method for the assessment of left ventricular function. It provides precise information on both global and segmental myocardial function by displaying endocardial motion and wall thickening. Dobutamine stress

  7. Spontaneous development of bilateral subdural hematomas in an infant with benign infantile hydrocephalus: color Doppler assessment of vessels traversing extra-axial spaces

    Energy Technology Data Exchange (ETDEWEB)

    Amodio, John; Spektor, Vadim; Pramanik, Bidyut; Rivera, Rafael; Pinkney, Lynne; Fefferman, Nancy [New York University Medical Center, Department of Radiology, New York, NY (United States)

    2005-11-01

    We present an infant with macrocrania, who initially demonstrated prominent extra-axial fluid collections on sonography of the brain, compatible with benign infantile hydrocephalus (BIH). Because of increasing macrocrania, a follow-up sonogram of the brain was performed; it revealed progressive enlargement of the extra-axial spaces, which now had echogenic debris. Color Doppler US showed bridging veins traversing these extra-axial spaces, so it was initially thought that these spaces were subarachnoid in nature (positive cortical vein sign). However, an arachnoid membrane was identified superior to the cortex, and there was compression of true cortical vessels beneath this dural membrane. An MRI of the brain showed the extra-axial spaces to represent bilateral subdural hematomas. The pathogenesis of spontaneous development of the subdural hematomas, in the setting of BIH, is discussed. We also emphasize that visualizing traversing bridging veins through extra-axial spaces does not necessarily imply that these spaces are subarachnoid in origin. (orig.)

  8. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  9. Screening of Chronic Obstructive Pulmonary Disease Patients for Pulmonary Arterial Hypertension Using Two-Dimensional Transthoracic Doppler Echocardiography in Tertiary Care Hospital in India

    Directory of Open Access Journals (Sweden)

    Vinay Mahishale

    2015-01-01

    Full Text Available Background: Chronic obstructive pulmonary disease (COPD and pulmonary arterial hypertension (PAH are common and underdiagnosed medical conditions in India. Prevalence of these chronic diseases is high both in rural and urban areas. However, the exact prevalence of PAH in Indian COPD patients is unclear. Comorbid conditions like PAH have a great impact on the outcome of COPD in the form of severity, exacerbations, morbidity, and mortality. Right heart catheterization remains the gold standard test for diagnosis of PAH, but it is invasive and practically not feasible. Aims and objectives: The present study objective was to screen COPD patients for PAH using two-dimensional transthoracic Doppler echocardiography (ECHO in Tertiary Care Hospital. Results: A total of 2040 patients with a confirmed diagnosis of COPD were enrolled in the study. Among these patients, 1509 were males (73.9%, 531 were females (23.06%, and 1428 were known or ex-smokers (70%. None of the females were smokers, but there was a history of biomass fuel exposure for >10 years. As per global initiative for chronic obstructive lung disease criteria, mild, moderate, severe, and very severe COPD was noted in 525,629,511, and 375 patients, respectively. When they were screened using ECHO, prevalence of PAH was 41.96% as 856 subjects had PAH. Prevalence of PAH among mild, moderate, severe, and very severe COPD was 23.8%, 34.81%, 48.53%, and 70.4%, respectively. There was a linear relationship between PAH and severity of COPD. Conclusion: PAH is very common in COPD patients in India. As the severity of COPD increased, the frequency and degree of PAH also increased. ECHO is an excellent tool for detection of PAH in COPD patients. All patients with severe to very severe COPD should be routinely screened by ECHO for PAH and with mild to moderate COPD, who have dyspnea out of proportion to their clinical condition should also be screened for PAH.

  10. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  11. The association between brain natriuretic peptide and tissue Doppler parameters in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Taliha Öner

    2016-01-01

    Full Text Available In this study, we investigated the association between brain natriuretic peptide (BNP levels and tissue Doppler imaging measurements and also screening for deadly mutations in patients with hypertrophic cardiomyopathy (HCM. We enrolled 20 patients diagnosed with HCM (age:10.7±5 years (1-17, 85% male, weight:42.25±23.10 kg, height:141.80±32.45 cm and 20 age, gender and body weight-matched control subjects. We performed electrocardiography, transthoracic echocardiography, and tissue Doppler echocardiography in each group, as well as genetic tests (for Arg403Gln, Arg453Cys, Arg719Trp and Arg719Gln mutations in MYH7 Exons 13, 14, 19 and BNP in the patients. The patients were divided into two groups according to the presence (Group 1 or absence (Group 2 of left ventricular (LV outflow tract obstruction. QTc dispersion and the LV ejection fraction and left atrial (LA volume index were increased in Group 1. The LA volume index and the mitral and septal E/Ea ratio and septum Z-score were increased while the mitral lateral annulus and septal annulus Ea wave velocities and the mitral and tricuspid E/A ratio were decreased in patients with high levels of BNP compared to those with normal BNP levels. There were no mutations that are associated with increased risk of sudden death found in patients included in this study. In the light of our data, we conclude that such parameters BNP levels above the 98 pg/mL, septal thickness Z-score ˃6, and higher mitral and septal E/Ea ratios can be used for management of patients with HCM according to life-threatening conditions.

  12. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention...

  13. MODERN POSSIBILITIES OF SPECKLE TRACKING ECHOCARDIOGRAPHY IN CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    V. S. Nikiforov

    2017-01-01

    Full Text Available Speckle-tracking echocardiography is promising modern technique for evaluation of structural and functional changes in the myocardium. It evaluates the indicator of global longitudinal myocardial deformation, which is more sensitive than ejection fraction to early changes of left ventricular contractility. The diagnostic capabilities of speckle tracking echocardiography are reflected in clinical recommendations and consensus statements of European Society of Cardiology (ESC, European Association of Cardiovascular Imaging (EACVI and American Society of Echocardiography (ASE. The aim of this paper is describe basic principles of speckle tracking echocardiography and clinical applications of this new technology. Attention is paid to the use of speckle tracking echocardiography in such heart pathologies as heart failure, coronary heart disease and myocardial infarction, left ventricular hypertrophy in arterial hypertension, hypertrophic cardiomyopathy and amyloidosis of the heart, valvular heart disease, constrictive pericarditis and cancer therapy-induced cardiotoxicity.

  14. Four-dimensional echocardiography area strain combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis.

    Science.gov (United States)

    Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li

    2017-09-01

    The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.

  15. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2014-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  16. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/ critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  17. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  18. Comparison of Hyperemic Impedance Echocardiography with Dobutamine Stress Echocardiography to Detect Inducible Myocardial Ischemia: A Pilot Study.

    Science.gov (United States)

    Patel, Jijibhoy J; Gupta, Ankur; Nanda, Navin C

    2016-03-01

    Stress echocardiography using exercise or pharmacological stressors is either contraindicated or associated with significant side effects in some patients. This pilot study was designed to evaluate a new technique, hyperemic impedance echocardiography (HIE). It is based on reactive coronary hyperemia when transient limb ischemia is induced by tourniquet inflation. We hypothesized that this physiologic coronary hyperemia can identify inducible myocardial ischemia by assessment of regional wall motion abnormalities on echocardiography when compared with dobutamine stress echocardiography (DSE). Twenty consecutive outpatients with suspected stable coronary artery disease (CAD) who underwent clinically indicated DSE were recruited for performance of HIE after informed consent was obtained. Standard graded dobutamine infusion protocol from 5 to 40 μg/kg per min was used for DSE. HIE was performed by inflating tourniquets at a pressure of 10 mmHg below the systolic blood pressure for 1 minute in three of four extremities at a time for total of four cycles. Echocardiography was performed immediately after the last rotating tourniquet deflation. DSE and HIE were classified as abnormal for development of new or worsening wall motion abnormality in at least one myocardial segment. Test characteristics were also determined for a subset of these patients (n = 12) who underwent clinically indicated coronary angiography. Hyperemic impedance echocardiography showed 86% sensitivity, 67% specificity, 86% positive predictive value, and 67% negative predictive value with a test accuracy of 80% to detect inducible myocardial wall motion abnormalities when compared with DSE. HIE also showed 83% sensitivity, 75% negative predictive value with a test accuracy of 66.7% for detection of significant (≥50% diameter stenosis) CAD on coronary angiography. In this pilot study, HIE was a feasible, safe, and promising method for detection of inducible myocardial ischemia by assessment of

  19. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  20. Color Doppler evaluation of the ocular arterial flow changes in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Ozer, Tulay; Altin, Remzi; Ugurbas, Suat Hayri; Ozer, Yetkin; Mahmutyazicioglu, Kamran; Kart, Levent

    2006-01-01

    Purpose: To evaluate the hemodynamic changes in the extraocular orbital vessels of the patients with chronic obstructive pulmonary disease (COPD), using color Doppler ultrasonography (CDU) technique, and to compare the results with those of healthy control subjects. Methods: Forty-five patients with COPD and 17 healthy control subjects were included in this study. Patients with COPD were classified according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD). Fifteen patients of stage I COPD (mild airflow limitation), stage II COPD (worsening airflow limitation) or stage III COPD (severe airflow limitation) were enrolled into Group I, II and III, respectively. End tidal carbon dioxide (EtCO 2 ), peripheral oxygen saturation (SpO 2 ), pulse rate (PR) and respiratory rate (RR) were measured by using capnograph/pulse oximeter in all patients. Measurements were performed in only one randomly chosen eye of each participant. The peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistance index (RI) were measured in the ophthalmic artery (OA), central retinal artery (CRA), lateral short posterior ciliary artery (LPCA) and medial short posterior ciliary artery (MPCA), using CDU technique. Results: The PSV measurements of the OA were significantly higher in Groups II and III compared to control group (p 2 with PSV (r = 0.53, p < 0.01) and EDV (r = 0.51, p < 0.01) of the OA. Statistically significant correlations were also found for the SpO2 with RI (r = -0.34, p < 0.05) in the OA. Conclusion: We concluded that COPD is associated with impaired retrobulbar hemodynamics, especially in the ophthalmic artery. Moreover, central retinal and posterior ciliary arteries with increased resistance are also found to be affected when compared with healthy control eyes

  1. Decision making in the treatment of peripheral arterial disease - A single-institution comparative study using information from color doppler and digital subtraction angiogram studies

    International Nuclear Information System (INIS)

    Koshy, Chiramel G; Chacko, Binita R; Keshava, Shyamkumar N; Stephen, Edwin; Agarwal, Sunil

    2011-01-01

    Numerous studies have compared the accuracy of color Doppler (CD) with that of digital subtraction angiography (DSA) in the diagnosis of peripheral arterial disease (PAD). However, only a few have looked at the influence of these diagnostic tests on the treatment decision in PAD. This study evaluated the differences in treatment decisions that were based on CD and with those based on DSA findings. Findings from CD and DSA studies obtained in 40 patients were entered on line diagrams by two radiologists working separately. These were randomized and sent to three experienced clinicians – two vascular surgeons and one interventional radiologist. The treatment decisions of the clinicians based on each proforma were collected and analyzed to look for the degree of agreement between Doppler-based and DSA-based decisions. There was fair to moderate agreement between CD-based and DSA-based decisions for all three clinicians, with some improvement in agreement with the addition of clinical data. The vascular surgeons showed better agreement with each other on treatment decisions compared to the interventional radiologist who showed a fair-to-moderate level of agreement with the vascular surgeons, which did not significantly change with the addition of clinical data. There is a fair to moderate agreement between treatment decisions based on CD findings and those based on DSA findings. We conclude that CD along with clinical data is sufficient to make decisions in the treatment of PAD

  2. Transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions%经阴道彩色多普勒超声在子宫内膜病变诊断的应用价值

    Institute of Scientific and Technical Information of China (English)

    高鸣

    2015-01-01

    目的 探讨经阴道彩色多普勒超声在子宫内膜病变诊断中的应用价值,总结其应用经验.方法 对90例不规则阴道流血患者行经阴道彩色多普勒超声检查,分析其超声影像学资料,并将超声检查结果与诊刮以及患者术后病理诊断结果相对照.结果 本研究90例患者经阴道彩色多普勒超声检查确诊86例,其中子宫内膜增生36例、子宫内膜息肉42例,子宫内膜癌8例,确诊率为95.64%;漏诊4例,漏诊率为4.36%,其中1例子宫内膜癌病变,3例子宫内膜增生病变.结论 经阴道彩色多普勒超声检查子宫内膜病变操作简便、准确性高,超声检查时应注意测量子宫内膜厚度,观察内膜形态、内膜与肌层的关系、内膜回声特点以及子宫内膜内血流情况及阻力指数,作为诊断子宫内膜病变的重要检查方法,还需要结合患者的临床表现及其他影像学检查手段,以提高其确诊率.%Objective To investigate the application value of transvaginal color Doppler ultrasound in the diagnosis of endometrial lesions,and summarize the application experience.Methods Ninety patients with irregular vaginal bleeding underwent transvaginal color Doppler ultrasound examination,the ultrasound image data were analyzed,and the ultrasonic inspection results and curettage and postoperative pathological diagnosis results were compared.Results Among the 90 cases,86 cases were diagnosed by transvaginal color Doppler ultrasound,of which 36 cases of endometrial hyperplasia,42 cases of endometrial polyps,endometrial carcinoma in 8 cases,the diagnosis rate was 95.64% ; 4 cases of missed diagnosis,the missed diagnosis rate was 4.36%,in which l case of endometrial carcinoma lesions,3 cases of uterus hyperplasia lesions.Conclusions Transvaginal color Doppler ultrasonography for endometrial lesions has simple operation,high accuracy,we should pay attention to measure the thickness of endometrium,endometrial morphology

  3. The role of Doppler measurement in the adducting uterine veins in diagnosis of endometrial tumors

    International Nuclear Information System (INIS)

    Abdullaev, R.Ya.; Pozdnyakov, S.A.

    2010-01-01

    The work deals with investigation of the capabilities of transvaginal ultrasound investigation in combination with color, energetic and spectral Doppler investigation in differential diagnosis of benign endometrial hyperplasia and cancer. The work is based on complex investigation of 66 pre- and post- menopause patients with histologically verified pathology of the endometrium.

  4. Quantification in echocardiography

    NARCIS (Netherlands)

    Korsten, H.H.M.; Mischi, M.; Grouls, R.J.E.; Jansen, A.H.M.; Dantzig, van J.M.; Peels, C.H.

    2006-01-01

    Until recently, more than 2200 Swan Ganz catheters were used annually in the operating rooms (OR) and intensive care unit (ICU) of the Catharina Hospital in Eindhoven, The Netherlands. After cardiologists who were specialists in echocardiography (ECHO) trained anesthesiologists in ECHO, the need for

  5. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  6. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  7. Basic heart examination: feasibility study of first-trimester systematic simplified fetal echocardiography.

    Science.gov (United States)

    Quarello, E; Lafouge, A; Fries, N; Salomon, L J

    2017-02-01

    First-trimester fetal cardiac screening examinations in low-risk populations should not have to meet the specifications required for high-risk populations. Our aim was to evaluate a simplified fetal echocardiographic ('basic heart') examination for early detection of severe congenital heart defects in a low-risk population. This was a first-trimester national 'flash study', performed over a 2-week period. Each observer was requested to perform simplified echocardiography without modifying the time and methods deemed necessary for the routine first-trimester ultrasound examination, in fetuses with crown-rump length between 45 and 84 mm. This basic heart assessment used targeted cross-sections of the four-chamber view (4CV) and of the three vessels and trachea (3VT) view, using color and/or directional power Doppler. All examinations were then reviewed offline and scored for quality by a qualified expert. Sixty observers performed a total of 597 first-trimester ultrasound examinations, each performing an average of 10 (range, 1-26) procedures. Examinations were conducted transabdominally (79%; 472/597), transvaginally (3%; 17/597) or both (18%; 108/597). In 8% (45/597) of cases, the fetal back was anterior, in 18% (108/597) it was on the left side, in 63% (377/597) it was posterior and in 11% (67/597) it was on the right side. It became clear during scoring by the expert that, unlike the Herman quality score for nuchal translucency measurement, it was difficult to assess the quality of these images without taking into account normality of the heart itself. Analysis of scores showed that the 4CV was obtained successfully and was deemed normal in 86% (512/597) of the patients, in 7% (41/597) it was deemed technically infeasible and in 7% (44/597) it was deemed feasible but atypical, which may have been due to the presence of an abnormality or to poor quality of the image. The 3VT view was obtained successfully and was normal in 79% (472/597) of the patients, in 13

  8. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  9. Doppler-Defined Pulmonary Hypertension in Sickle Cell Anemia in Kurdistan, Iraq.

    Science.gov (United States)

    Al-Allawi, Nasir; Mohammad, Ameen M; Jamal, Shakir

    2016-01-01

    To determine the frequency, clinical and laboratory associations of pulmonary hypertension in Iraqi Kurds with sickle cell anemia, a total of ninety four such patients attending a major hemoglobinopathy center in Iraqi Kurdistan were enrolled. All patients were re-evaluated clinically and had their blood counts, HbF, serum ferritin, LDH, renal and liver function assessed. Transthoracic Doppler echocardiography with measurement of tricuspid valve regurgitant jet velocity (TRV) was performed. A TRV in excess of 2.8 m/s was considered for the purposes of this study as indicative of pulmonary hypertension (PH). The prevalence of TRV in excess of 2.8m/s was 10.6%. By univariate analysis: significantly higher reticulocyte count, more frequent blood transfusions and pain episodes were encountered in the PH group as compared to the non-PH group (p = 0.001, 0.045 and 0.02 respectively). Moreover, PH patients had significantly higher mean right atrial area, left atrial size, E wave/A wave ratio and ejection fraction by echocardiography (p = 0.027, 0.037, <0.001 and 0.008 respectively). Except for reticulocyte count none of the other parameters remained significant by multivariate analysis (p = 0.024). In conclusion the current study revealed that pulmonary hypertension is rather frequent among Iraqi Kurds with sickle cell anemia, and identified reticulocyte count as an independently associated parameter with PH in this population. Future prospective studies including right heart catheterization and appropriate medical intervention are warranted.

  10. Teaching focused echocardiography for rheumatic heart disease screening

    Directory of Open Access Journals (Sweden)

    Daniel Engelman

    2015-01-01

    Full Text Available Screening for rheumatic heart disease (RHD requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities.

  11. Teaching focused echocardiography for rheumatic heart disease screening

    International Nuclear Information System (INIS)

    Engelman, Daniel; Kado, Joseph H; Reményi, Bo; Colquhoun, Samantha M; Watson, Caroline; Rayasidamu, Sera C; Steer, Andrew C

    2005-01-01

    Screening for rheumatic heart disease (RHD) requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis) and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities

  12. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  13. Measurement of left ventricular torsion using block-matching-based speckle tracking for two-dimensional echocardiography

    Science.gov (United States)

    Sun, Feng-Rong; Wang, Xiao-Jing; Wu, Qiang; Yao, Gui-Hua; Zhang, Yun

    2013-01-01

    Left ventricular (LV) torsion is a sensitive and global index of LV systolic and diastolic function, but how to noninvasively measure it is challenging. Two-dimensional echocardiography and the block-matching based speckle tracking method were used to measure LV torsion. Main advantages of the proposed method over the previous ones are summarized as follows: (1) The method is automatic, except for manually selecting some endocardium points on the end-diastolic frame in initialization step. (2) The diamond search strategy is applied, with a spatial smoothness constraint introduced into the sum of absolute differences matching criterion; and the reference frame during the search is determined adaptively. (3) The method is capable of removing abnormal measurement data automatically. The proposed method was validated against that using Doppler tissue imaging and some preliminary clinical experimental studies were presented to illustrate clinical values of the proposed method.

  14. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  15. Low-frequency high-definition power Doppler in visualizing and defining fetal pulmonary venous connections.

    Science.gov (United States)

    Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong

    2014-07-01

    The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.

  16. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Haahr-Pedersen, Sune Ammentorp

    2011-01-01

    The objective of this study was to evaluate the prognostic value of the myocardial performance index (MPI), assessed by color-coded tissue Doppler imaging (TDI) M-mode through the anterior mitral leaflet. Color TDI M-mode through the mitral leaflet is an easy, very fast, and precise method...... ventricular in- and outflow using standard procedures (MPI(conv)) and by color-coded TDI M-mode through the mitral leaflet in the apical 4-chamber view (MPI(TDI)). MPI(TDI) was increased in subjects with coronary heart disease (CHD) compared to controls, even after multivariable adjustment (p

  17. Dobutamine stress echocardiography: a review and update

    Directory of Open Access Journals (Sweden)

    Gilstrap LG

    2014-04-01

    Full Text Available Lauren Gray Gilstrap,1 R Sacha Bhatia,2 Rory B Weiner,3 David M Dudzinski3 1Division of Cardiology, Brigham and Women's Hospital, Boston, MA, USA; 2Institute for Health Systems Solutions, Women's College Hospital, Toronto, ON, Canada; 3Cardiology Division, Massachusetts General Hospital, Boston, MA, USA Abstract: Stress echocardiography is a noninvasive cardiovascular diagnostic test that provides functional and hemodynamic information in the assessment of a number of cardiac diseases. Performing stress echocardiography with a pharmacologic agent such as dobutamine allows for simulation of increased heart rate and increased myocardial physiologic demands in patients who may be unable to exercise due to musculoskeletal or pulmonary comorbidities. Dobutamine stress echocardiography (DSE, like exercise echocardiography, has found its primary application in ischemic heart disease, with roles in identification of obstructive epicardial coronary artery disease, detection of viable myocardium, and assessment of the efficacy of anti-ischemic medical therapy in patients with known coronary artery disease. DSE features prominently in the evaluation and management of valvular heart disease by helping to assess the effects of mitral and aortic stenoses, as well as a specific use in differentiating true severe valvular aortic stenosis from pseudostenosis that may occur in the setting of left ventricular systolic dysfunction. DSE is generally well tolerated, and its side effects and contraindications generally relate to consequences of excess inotropic and/or chronotropic stimulation of the heart. The aim of this paper is to review the indications, contraindications, advantages, disadvantages, and risks of DSE. Keywords: stress echocardiography, dobutamine, coronary artery disease, myocardial ischemia

  18. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2003-09-15

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  19. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol

    2003-01-01

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 ± 39.7 ml/min for the right side and 127.6 ± 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 ± 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 ± 59.19 ml/min in male, and 217.28 ± 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  20. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  1. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    Science.gov (United States)

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (page of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  2. Head-to-head comparison of peak supine bicycle exercise echocardiography and treadmill exercise echocardiography at peak and at post-exercise for the detection of coronary artery disease.

    Science.gov (United States)

    Peteiro, Jesús; Bouzas-Mosquera, Alberto; Estevez, Rodrigo; Pazos, Pablo; Piñeiro, Miriam; Castro-Beiras, Alfonso

    2012-03-01

    Supine bicycle exercise (SBE) echocardiography and treadmill exercise (TME) echocardiography have been used for evaluation of coronary artery disease (CAD). Although peak imaging acquisition has been considered unfeasible with TME, higher sensitivity for the detection of CAD has been recently found with this method compared with post-TME echocardiography. However, peak TME echocardiography has not been previously compared with the more standardized peak SBE echocardiography. The aim of this study was to compare peak TME echocardiography, peak SBE echocardiography, and post-TME echocardiography for the detection of CAD. A series of 116 patients (mean age, 61 ± 10 years) referred for evaluation of CAD underwent SBE (starting at 25 W, with 25-W increments every 2-3 min) and TME with peak and postexercise imaging acquisition, in a random sequence. Digitized images at baseline, at peak TME, after TME, and at peak SBE were interpreted in a random and blinded fashion. All patients underwent coronary angiography. Maximal heart rate was higher during TME, whereas systolic blood pressure was higher during SBE, resulting in similar rate-pressure products. On quantitative angiography, 75 patients had coronary stenosis (≥50%). In these patients, wall motion score indexes at maximal exercise were higher at peak TME (median, 1.45; interquartile range [IQR], 1.13-1.75) than at peak SBE (median, 1.25; IQR, 1.0-1.56) or after TME (median, 1.13; IQR, 1.0-1.38) (P = .002 between peak TME and peak SBE imaging, P peak TME (median, 5; IQR, 2-12) compared with peak SBE (median, 3; IQR, 0-8) or after TME (median, 2; IQR, 0-4) (P peak TME and peak SBE imaging, P peak TME, peak SBE, and post-TME echocardiography for CAD was 84%, 75%, and 60% (P = .001 between post-TME and peak TME echocardiography, P = .055 between post-TME and peak SBE echocardiography), with specificity of 63%, 80%, and 78%, respectively (P = NS) and accuracy of 77%, 77%, and 66%, respectively (P = NS). Peak TME

  3. Increased left ventricular mass index is present in patients with type 2 diabetes without ischemic heart disease

    DEFF Research Database (Denmark)

    Seferovic, Jelena P; Tesic, Milorad; Seferovic, Petar M

    2018-01-01

    , stress echocardiography, transthoracic 2D Doppler and tissue Doppler echocardiography were performed. Multivariable logistic regression was used to determine the independent association with T2DM. Linear regression models and Pearson's correlation were used to assess the correlations between LVMI.......029). A positive correlation of LVMI was found with fasting glucose (p 

  4. Echocardiography in the flight program

    Science.gov (United States)

    Charles, John B.; Bungo, Michael W.; Mulvagh, Sharon L.

    1991-01-01

    Observations on American and Soviet astronauts have documented the association of changes in cardiovascular function during orthostasis with space flight. A basic understanding of the cardiovascular changes occurring in astronauts requires the determination of cardiac output and total peripheral vascular resistance as a minimum. In 1982, we selected ultrasound echocardiography as our means of acquiring this information. Ultrasound offers a quick, non-invasive and accurate means of determining stroke volume which, when combined with the blood pressure and heart rate measurements of the stand test, allows calculation of changes in peripheral vascular resistance, the body's major response to orthostatic stress. The history of echocardiography in the Space Shuttle Program is discussed and the results are briefly presented.

  5. Sonographic evaluation of thyroiditis with color flow study.

    Science.gov (United States)

    Sultana, N; Rima, S; Rahman, S; Azad, S A; Karim, M E; Shawkat, S; Ahsan, M; Kamal, M M; Begum, M

    2014-01-01

    This cross sectional study was carried out in the Department of Radiology and Imaging, Bangabandhu Sheikh Mujib Medical University, Bangladesh in collaboration with the Department of Endocrinology and Department of Histopathology of the same hospital during the period of March 2007 to February 2008 to determine efficacy of ultrasonogram in the evaluation of thyroiditis and to compare its results with color flow Doppler study. For this purpose, a total of 50 patients having clinical suspicion of thyroiditis were enrolled in this study. Ultrasound and color Doppler were done in all these patients. Then all patients underwent for FNAC in the Histopathology department. Correlation between sonographic diagnosis and histopathological diagnosis were observed. Out of these 50 patients 10(20%) were male and 40 (80%) were female with age ranging from 12 to 50 years, highest between 21 to 30 years. The mean age of the patients was 30.42±9.57 years. On unltrasonographic findings of thyroid gland 42.0% patients had regular and 58.0% had irregular margin. Seventy percent had fibrosis, 14.0% had feature of necrosis, 48.0% had lymphadenopathy. Out of all patients 6.0% had normal echogenic feature, 16.0% had increased and 78.0% decreased echogeneic feature. Twelve percent (12.0%) patients had homogeneous and 88.0% had heterogeneous pattern of echogenecity. Thirty eight percent (38%) patients had focal nodules. Sixty percent (60.0%) patients had focal swelling and 40.0% had diffuse swelling. On color flow Doppler 28.0% had normal, 38.0% had increased and 34.0% decreased vascular flow pattern. USG reports revealed that 48.0% had thyromegaly, 36.0% had thyroid nodule, 10.0% had multinodular goiter and 6.0% had thyroid abscess. FNAC diagnosis revealed that 34.0% patients had Hashimoto's thyroiditis, 24.0% had lymphocytic thyroiditis, 18.0% had granulomatous thyroiditis, 6.0% had abscess, 8.0% had goitre and 10.0% nonspecific. USG and CFD are recommended modalities for the diagnosis of

  6. 3D Harmonic Echocardiography:

    NARCIS (Netherlands)

    M.M. Voormolen (Marco)

    2007-01-01

    textabstractThree dimensional (3D) echocardiography has recently developed from an experimental technique in the ’90 towards an imaging modality for the daily clinical practice. This dissertation describes the considerations, implementation, validation and clinical application of a unique

  7. Echocardiography in Infective Endocarditis: State of the Art.

    Science.gov (United States)

    Afonso, Luis; Kottam, Anupama; Reddy, Vivek; Penumetcha, Anirudh

    2017-10-25

    In this review, we examine the central role of echocardiography in the diagnosis, prognosis, and management of infective endocarditis (IE). 2D transthoracic echocardiography (TTE) and transesophageal echocardiography TEE have complementary roles and are unequivocally the mainstay of diagnostic imaging in IE. The advent of 3D and multiplanar imaging have greatly enhanced the ability of the imager to evaluate cardiac structure and function. Technologic advances in 3D imaging allow for the reconstruction of realistic anatomic images that in turn have positively impacted IE-related surgical planning and intervention. CT and metabolic imaging appear to be emerging as promising ancillary diagnostic tools that could be deployed in select scenarios to circumvent some of the limitations of echocardiography. Our review summarizes the indispensable and central role of various echocardiographic modalities in the management of infective endocarditis. The complementary role of 2D TTE and TEE are discussed and areas where 3D TEE offers incremental value highlighted. An algorithm summarizing a contemporary approach to the workup of endocarditis is provided and major societal guidelines for timing of surgery are reviewed.

  8. Dobutamine Stress Echocardiography and Tissue Synchronization Imaging

    Science.gov (United States)

    Tas, Hakan; Gundogdu, Fuat; Gurlertop, Yekta; Karakelleoglu, Sule

    2008-01-01

    Dobutamine stress echocardiography has emerged as a reliable method for the diagnosis of coronary artery disease and the management of its treatment. Several studies have shown that that this technique works with 80–85% accuracy in comparison with other imaging methods. There are few studies aimed at developing the clinical utility of dobutamine stress echocardiography for the evaluation of normal and abnormal segments that result from dobutamine stress with Tissue Synchronization Imaging. PMID:25610034

  9. Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    Science.gov (United States)

    2011-01-01

    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data. PMID:21943283

  10. Validation of noninvasive indices of global systolic function in patients with normal and abnormal loading conditions: a simultaneous echocardiography pressure-volume catheterization study.

    Science.gov (United States)

    Yotti, Raquel; Bermejo, Javier; Benito, Yolanda; Sanz-Ruiz, Ricardo; Ripoll, Cristina; Martínez-Legazpi, Pablo; del Villar, Candelas Pérez; Elízaga, Jaime; González-Mansilla, Ana; Barrio, Alicia; Bañares, Rafael; Fernández-Avilés, Francisco

    2014-01-01

    Noninvasive indices based on Doppler echocardiography are increasingly used in clinical cardiovascular research to evaluate left ventricular global systolic chamber function. Our objectives were to clinically validate ultrasound-based methods of global systolic chamber function to account for differences between patients in conditions of abnormal load, and to assess their sensitivity to load confounders. Twenty-seven patients (8 dilated cardiomyopathy, 10 normal ejection fraction, and 9 end-stage liver disease) underwent simultaneous echocardiography and left heart catheterization with pressure-conductance instrumentation. The reference index, maximal elastance (Emax), was calculated from pressure-volume loop data obtained during acute inferior vena cava occlusion. A wide range of values were observed for left ventricular systolic chamber function (Emax: 2.8±1.0 mm Hg/mL), preload, and afterload. Among the noninvasive indices tested, the peak ejection intraventricular pressure difference showed the best correlation with Emax (R=0.75). A significant but weaker correlation with Emax was observed for ejection fraction (R=0.41), midwall fractional shortening (R=0.51), global circumferential strain (R=-0.53), and strain rate (R=-0.46). Longitudinal strain and strain rate failed to correlate with Emax, as did noninvasive single-beat estimations of this index. Principal component and multiple regression analyses demonstrated that peak ejection intraventricular pressure difference was less sensitive to load, whereas ejection fraction and longitudinal strain and strain rate were heavily influenced by afterload. Current ultrasound methods have limited accuracy to characterize global left ventricular systolic chamber function in a given patient. The Doppler-derived peak ejection intraventricular pressure difference should be preferred for this purpose because it best correlates with the reference index and is more robust in conditions of abnormal load.

  11. Role of imaging techniques in the evaluation of cardiovascular drugs

    International Nuclear Information System (INIS)

    Sugishita, Yasuro; Matsuda, Mitsuo; Ajisaka, Ryuichi

    1985-01-01

    In order to investigate the role of imaging in the evaluation of medical treatment in heart diseases, radionuclide angiocardiography, echocardiography and Doppler echocardiography were applied in the cases of various kinds of heart diseases. Acute and chronic effects of antianginal drugs (nitrates, calcium antagonists and beta-blockers) could be evaluated by exercise radionuclide angiocardiography or exercise echocardiography in the cases of effort angina. The effects of the drugs changing myocardial contractility, preload or afterload could be evaluated by echocardiography in various kinds of heart diseases, including valvular heart biseases. The effect of calcium antagonists in improving diastolic function in hypertrophic cardiomyopathy could be evaluated by echocardiography or Doppler echocardiography. In conclusion, imaging techniqus are valuable and useful methods to evaluate the effects of cardiovascular drugs, by offering various informations. (author)

  12. Exercise right heart catheterization for pulmonary hypertension identified on screening echocardiography in adult survivors of childhood cancer: A report from the St. Jude Lifetime Cohort.

    Science.gov (United States)

    Armstrong, Gregory T; Tolle, James J; Piana, Robert; Santucci, Aimee; Leathers, James; Ness, Kirsten K; Mulrooney, Daniel A; Green, Daniel M; Joshi, Vijaya M; Robison, Leslie L; Hudson, Melissa M; Lenihan, Daniel

    2018-01-01

    Pulmonary hypertension, determined noninvasively by tricuspid regurgitant jet velocity on Doppler echocardiography, was previously identified in 25% of long-term survivors who received chest-directed radiotherapy. To validate noninvasively defined pulmonary hypertension, survivors (mean age 48 years), exposed to chest radiotherapy, underwent right heart catheterization with planned cardiopulmonary exercise testing during catheterization. Eight participants had an elevated mean pulmonary artery pressure at rest (≥25 mm Hg) or with subsequent exercise (>30 mm Hg), evidence of hemodynamically confirmed pulmonary hypertension by right heart catheterization. Cardiopulmonary exercise testing further defined the magnitude and etiology of cardiopulmonary limitations in this life-threatening late effect. © 2017 Wiley Periodicals, Inc.

  13. Prognostic implications of left ventricular diastolic dysfunction with preserved systolic function following acute myocardial infarction

    DEFF Research Database (Denmark)

    Poulsen, S H; Møller, J E; Nørager, B

    2001-01-01

    of the mitral and pulmonary venous flow, and the propagation velocity of early mitral flow by color M-mode Doppler echocardiography in 183 consecutive patients at day 5-7 following their first acute MI. Patients were classified into four groups: group A: preserved LV systolic and diastolic function (n = 73......%) and D (38%) compared to A (2%) (p class >or=II (p = 0.006), and age (0.008) as predictors of cardiac death or readmission due to heart failure. The presence of LV diastolic dysfunction with preserved......The contribution of diastolic dysfunction in patients with preserved left ventricular (LV) systolic function to impaired functional status and cardiac mortality in myocardial infarction (MI) is unknown. In the present study, assessment of LV diastolic function was performed by Doppler analysis...

  14. The Role of Focused Echocardiography in Pediatric Intensive Care: A Critical Appraisal

    Science.gov (United States)

    Gaspar, Heloisa Amaral; Morhy, Samira Saady

    2015-01-01

    Echocardiography is a key tool for hemodynamic assessment in Intensive Care Units (ICU). Focused echocardiography performed by nonspecialist physicians has a limited scope, and the most relevant parameters assessed by focused echocardiography in Pediatric ICU are left ventricular systolic function, fluid responsiveness, cardiac tamponade and pulmonary hypertension. Proper ability building of pediatric emergency care physicians and intensivists to perform focused echocardiography is feasible and provides improved care of severely ill children and thus should be encouraged. PMID:26605333

  15. Echocardiography in Ebstein's anomaly

    NARCIS (Netherlands)

    W.J. Gussenhoven (Wilhelmina Johanna)

    1984-01-01

    textabstractIn this thesis the value of echocardiography is evaluated for the diagnosis of Ebstein's anomaly of the tricuspid valve. This congenital heart defect, first described in 1866 by Wilhelm Ebstein, is characterized by an apical displacement of the septal and inferior tricuspid valve

  16. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  17. Diagnosic evaluation study of color doppler ultrasonic examination in abdominal wall endometriosis%彩色多普勒高频超声对腹壁子宫内膜异位症的诊断价值研究

    Institute of Scientific and Technical Information of China (English)

    史淼; 亓恒涛; 王倩; 张东东; 章阳

    2014-01-01

    Objective To explore the color doppler ultrasound manifestation of abdominal wall endometriosis,and evaluate its clinical value. Methods The manifestation of two-dimensional high frequency ultrasonography and color doppler imaging of 36 patients withabdominal wall endometriosis,which proven by surgery and pathology,were retrospectively analyzed.Results Among the 36 patients with abdominal wall endometriosis,1 6 cases located in fat layer,20 cases in muscular layer,with diameter ranging from 1 .1 to 5 .2 cm.With two-dimensionalultrasonography,there was no capsule,but with irregular morphology,blurred margins,low echoes inside and some parts of irregular no-echo areas.The size and internal echo of the mass changed respectively according to the menstruation.Color doppler ultrasound showed scattered or striped flow signals in the lesion,whose artery displayed low-speed and high resistance frequency spectrum.The accuracy and misdiagnosis rate of ultrasonography were 83.3% and 1 6.7%, respectively.Conclusions The color doppler ultrasound may directlydisplay the size,morphology,condition of internal echo and blood inflow of the abdominal wall endometriosis lesion.Therefore,it is the first choice of imaging examination for the diagnosis of abdominal wall endometriosis.%目的:探讨腹壁子宫内膜异位症的彩色多普勒高频超声表现,评价其临床应用价值。方法回顾性分析2010年2月至2013年12月,山东省聊城市人民医院经手术病理证实的腹壁子宫内膜异位症患者36例的高频超声二维图像及彩色多普勒超声表现。结果36例腹壁子宫内膜异位症患者中,位于脂肪层内16例,位于肌层内20例,直径1.1~5.2 cm。二维超声表现:无包膜,形态不规则,边缘不光滑,内部为不均质低回声,随月经的不同时期肿块大小及回声呈相应改变。彩色多普勒超声显示病灶内部可见点状或条状血流信号,其动脉均为

  18. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  19. Targeted neonatal echocardiography services: need for standardized training and quality assurance.

    Science.gov (United States)

    Finan, Emer; Sehgal, Arvind; Khuffash, Afif El; McNamara, Patrick J

    2014-10-01

    Targeted neonatal echocardiography refers to a focused assessment of myocardial performance and hemodynamics directed by a specific clinical question. It has become the standard of care in many parts of the world, but practice is variable, and there has been a lack of standardized training and evaluation to date. Targeted neonatal echocardiography was first introduced to Canada in 2006. The purpose of this study was to examine the characteristics of targeted neonatal echocardiography practice and training methods in Canadian neonatal intensive care units (NICUs). A total of 142 Canadian neonatologists were invited to participate in an online survey, which was conducted in September 2010. The survey consisted of questions related to the availability of targeted neonatal echocardiography, clinical indications, benefits and risks, and training methods. The overall survey response rate was 65%. Forty-eight respondents (34%) indicated that targeted neonatal echocardiography was available in their units, and the program was introduced within the preceding 1 to 5 years. In centers where it was unavailable, lack of on-site echocardiography expertise was cited as the major barrier to implementation. The most common indications for targeted neonatal echocardiography included evaluation of a hemodynamically significant ductus arteriosus, systemic or pulmonary blood flow, and response to cardiovascular treatments. Only 27% of respondents, working in centers where targeted neonatal echocardiography existed, actually performed the studies themselves; most individuals completed 11 to 20 studies per month. Almost half of the respondents said that training was available in their institutions, but methods of training and evaluation were inconsistent. Eighty-seven percent of respondents reported no formalized process for assessment of ongoing competency after the initial training period. Targeted neonatal echocardiography is becoming more widely available and is gaining acceptance in

  20. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  1. Ecocardiografia por Doppler tecidual no diagnóstico de rejeição após transplante cardíaco Ecocardiografía con Doppler tisular en el diagnóstico de rechazo después de transplante cardíaco Tissue doppler echocardiography in the diagnosis of heart transplantation rejection

    Directory of Open Access Journals (Sweden)

    Marcos Valério Coimbra Resende

    2011-07-01

    Full Text Available FUNDAMENTO: A biópsia endomiocárdica (BEM é o método padrão-ouro para o diagnóstico de rejeição celular (RC após transplante cardíaco (TC. OBJETIVO: Testar a hipótese de que o exame de imagem por Doppler tecidual (IDT pode detectar RC > 3A e agregar informação diagnóstica, comparado ao Doppler convencional. MÉTODOS: Cinquenta e quatro pacientes com TC foram submetidos à BEM e estudo ecocardiográfico através de IDT em até 24 horas. Comparamos os pacientes com TC e RC > 3A com pacientes com TC e RC 3A em 39/129 (30,2% das BEM. O melhor preditor isolado para o diagnóstico de RC foi a a'LAT, com sensibilidade de 76,3%, especificidade de 73,8% (p = 0,001. Na análise multivariada, a a'LAT (p = 0,001, a'SEP (p = 0,002, relação e'/a' LAT (p = 0,006, relação e'Mitral/ e'LAT (p = 0,014, SINF (p = 0,009 foram preditores de RC > 3A. Obtivemos um escore com sensibilidade de 88,2%, acurácia de 79,6%, e valor preditivo negativo de 92,9% para diagnosticar RC > 3A. O Doppler convencional (fluxo mitral e pulmonar venoso não foi relevante para predizer a RC > 3A. CONCLUSÃO: O estudo de IDT agregou informação diagnóstica para predizer RC > 3A quando comparado ao Doppler convencional. O modelo baseado em IDT pode ser tornar um método em potencial para detectar RC > 3A após TC.FUNDAMENTO: La biopsia endomiocárdica (BEM es el método gold standard para el diagnóstico de rechazo celular (RC después de transplante cardíaco (TC. OBJETIVO: Testear la hipótesis de que el examen de imagen con Doppler tisular (IDT puede detectar RC > 3A y agregar información diagnóstica, comparado al Doppler convencional. MÉTODOS: Cincuenta y cuatro pacientes con TC fueron sometidos a BEM y estudio ecocardiográfico a través de IDT en hasta 24 horas. Comparamos los pacientes con TC y RC > 3A con pacientes con TC y RC 3A en 39/129 (30,2% de las BEM. El mejor predictor aislado para el diagnóstico de RC fue la a'LAT, con sensibilidad de 76

  2. Echocardiography in the adult's congenital cardiopaties

    International Nuclear Information System (INIS)

    Escobar Q, Carlos I; Jaramillo U, Mario; Tenorio, Luis F; Molina V, Claudia; Saldarriaga A, Marcela; Arango, Angela M

    2003-01-01

    The number of adults with congenital heart disease is steadily increasing in the course of time. We ignore the prevalence and the most frequent diagnoses in our environment. A descriptive prospective study is presented. Between November 1 1999 and July 31 2001, 8871 Tran-thoracic and Tran-esophageal echocardiographies were performed in the Clinica Cardiovascular Santa Maria's echocardiography service. We found 143 congenital cardiopathies (1.6%) in 74 men and 69 women with a mean age of 37.7 +/- 18.4 years. the most frequent diagnoses were bicuspid aortic valve, atrial septal defect, ventricular septal defect, patent ductus arteriosus and Ebstein's anomaly. these findings agree with world wide data

  3. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  4. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  5. Comparative study between MRI and echocardiography in noncompaction of ventricular myocardium

    International Nuclear Information System (INIS)

    Sun Ziyan; Xia Liming; Wang Chengyuan; Rao Jingjing; Shenyu Weihui

    2007-01-01

    Objective: To investigate the MRI and echocardiography manifestations of noncompaction of ventricular myocardium(NVM) and assess the role of MR1 in the diagnosis of NVM by comparing it with echocardiography. Methods: Fourteen cases of NVM diagnosed by echocardiography were examined with MRI, including scanning of black-blood sequences, double inversion recovery fast spin echo (DIBFSE) and triple inversion recovery fast spin echo (TIRFSE), and white blood sequence: fast imaging employ steady state acquisition (FIESTA). Scanning plane includes short axis view, four-chamber view and long axis view. Results: Both MRI and echocardiography displayed involvement of left ventricles in thirteen cases and involvement of double ventricles in one case. Apexes of heart and the intermedius are commonly affected. MRI showed 54 segments and echocardiography showed 53 segments affected, and there is no significant difference between the capability of MRI and echocardiography (P=1,000). The affected myocardium consisted of two layers: subendocardial noncompacted myocardium and epicardial compacted myocardium, and the ratio measurement of N/C by MRI was 3.37±0.89 and it was 3.19±0.82 by echocardiography. Noncompacted myocardium was characterized by prominent and excessive myocardial trabeculations and deep intratrabecular recesses, in which the blood flow was communicated with the ventricle. One case was complicated with ventricular aneurysm, and coronary arteriography was performed with unremarkable findings. One case underwent heart transplantation because of progressive heart failure, Gross findings demonstrated prominent muscular' trabeculations with deep intratrabecular recesses, which coincided well with MRI findings. Conclusion: The MRI manifestation of NVM is characteristic, and MRI with multiple series and planes is helpful in the diagnose of NVM. Compared with echocardiography, MRI could display the pathological cardiac muscle more clearly, because of its high soft

  6. Evidence of abnormal left ventricular function in patients with thalassaemia major: an echocardiography based study

    International Nuclear Information System (INIS)

    Sohail, M.; Hyder, S.N.

    2009-01-01

    Thalassaemia represent one of the most common single gene disorder causing a major public health problem in Pakistan. Nearly 100,000 people are born worldwide with this severe blood disorder every year. Over the last 3 decades, the development of regular transfusion therapy and iron chelation has dramatically improved the quality of life and transformed thalassaemia from a rapidly fatal disease to a chronic disease compatible with prolonged survival. Objective of this observational cross sectional study was to determine the effects of chronic anaemia and transfusional iron overload on the left ventricular function using Doppler echocardiography. This study was conducted in the Department of Paediatric Cardiology, The Children's Hospital and Institute of Child Health, Lahore, Pakistan from first April 2006 to September 30, 2007. The study comprised of 50 consecutive cases of beta-Thalassaemia major and 30 controls with normal haemoglobin and electrophoresis pattern. beta- Thalassaemia major patients were diagnosed on the basis of haemoglobin electrophoresis. Patients with any congenital or acquired heart disease, concurrent infective disorder and with history of cardiac surgery were excluded from the study. 2-D, M-mode and Doppler echocardiography was performed in all the study cases and controls. Statistical comparison of study cases and controls was conducted by using unpaired t-test. The age of the patients ranged from 2 years to 25 years with mean age of 9.65 years. Males were 34 (68%) and females were 16 (32%). None of the study cases was on regular chelation programme while 31 (62%) patients were on irregular chelation with single dose of intravenous desferrioxamine only at the time of blood transfusion. 19 (38%) of the patients had LV dysfunction in the form of isolated systolic dysfunction in 2 (4%), isolated diastolic dysfunction in 15 (30%) while global dysfunction in 2 (4%) of the patients. Left ventricular dimensions, stroke volume and E/A ratio were

  7. Speckle tracking echocardiography in acute lupus myocarditis: comparison to conventional echocardiography

    Directory of Open Access Journals (Sweden)

    Riëtte Du Toit

    2017-07-01

    Full Text Available Aims: Lupus myocarditis occurs in 5–10% of patients with systemic lupus erythematosus (SLE. No single feature is diagnostic of lupus myocarditis. Speckle tracking echocardiography (STE can detect subclinical left ventricular dysfunction in SLE patients, with limited research on its utility in clinical lupus myocarditis. We report on STE in comparison to conventional echocardiography in patients with clinical lupus myocarditis. Methods and results: A retrospective study was done at a tertiary referral hospital in South Africa. SLE patients with lupus myocarditis were included and compared to healthy controls. Echocardiographic images were reanalyzed, including global longitudinal strain through STE. A poor echocardiographic outcome was defined as final left ventricular ejection fraction (LVEF <40%. 28 SLE patients fulfilled the criteria. Global longitudinal strain correlated with global (LVEF: r = −0.808; P = 0.001 and regional (wall motion score: r = 0.715; P < 0.001 function. In patients presenting with a LVEF ≥50%, global longitudinal strain (P = 0.023, wall motion score (P = 0.005 and diastolic function (P = 0.004 were significantly impaired vs controls. Following treatment, LVEF (35–47% (P = 0.023 and wall motion score (1.88–1.5 (P = 0.017 improved but not global longitudinal strain. Initial LVEF (34%; P = 0.046 and global longitudinal strain (−9.5%; P = 0.095 were lower in patients with a final LVEF <40%. Conclusions: This is the first known report on STE in a series of patients with clinical lupus myocarditis. Global longitudinal strain correlated with regional and global left ventricular function. Global longitudinal strain, wall motion score and diastolic parameters may be more sensitive markers of lupus myocarditis in patients presenting with a preserved LVEF ≥50%. A poor initial LVEF and global longitudinal strain were associated with a persistent LVEF <40%. Echocardiography is a non-invasive tool with diagnostic and

  8. Changes in cardiac function and structure in newly diagnosed Graves' disease. A conventional and 2D-speckle tracking echocardiography study.

    Science.gov (United States)

    Aroditis, K; Pikilidou, M; Vourvouri, E; Hadjistavri, L; Zebekakis, P; Yovos, J; Efthimiadis, G; Karvounis, H

    2017-02-01

    Overproduction of thyroid hormones leads to structural as well as functional cardiac changes. Conventional echocardiography but also recently developed sophisticated two-dimensional echocardiography speckle (2D-STE) tracking allow elaborate evaluation of these changes. Our purpose was to investigate the effects of thyroid hormones overproduction on the heart in patients with Graves' disease and changes that occur after 6 months thyrostatic therapy. We conducted a prospective, case-control study of 6 months duration. Full echocardiographic assessment at diagnosis and after 6 months of thyrostatic therapy were performed in 44 patients with Graves' disease, aged 37.6 ± 9.1 years. Additionally, 43 euthyroid controls were studied for the same time period. Left ventricular end diastolic diameter (LVEDD) and left ventricular end systolic diameter (LVESD) were higher in the patient group while triscupid annular plane systolic excursion (TAPSE) was lower in the patient group. Moreover, left ventricular (LV) mass index and left atrium (LA) volume index were higher in the Graves' disease group. Diastolic impairment as assessed with conventional echocardiography including tissue Doppler was present in the patient group (E/A ratio 0.87 ± 0.10,). 2D-STE analysis, revealed an increase in the strain rate at the isovolumic relaxation time (SRIVRT, 0.310 ± 0.07 patients versus 0.298 ± 0.09 s -1 controls). Improvement in diastolic and right systolic function as well as in left ventricular structural parameters was observed after restoration of euthyroidism (E/A ratio from 0.87 ± 0.10 versus 0.9 ± 0.08, p < 0.05). Patients with newly diagnosed Graves' showed an improvement in diastolic function, right systolic function and structural parameters after 6 months of thyrostatic treatment.

  9. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  10. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    DEFF Research Database (Denmark)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel

    2018-01-01

    ) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. RESULTS: 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D...... echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different...... between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r

  11. Exercise stress echocardiography in patients with valvular heart disease.

    Science.gov (United States)

    Sharma, Vishal; Newby, David E; Stewart, Ralph A H; Lee, Mildred; Gabriel, Ruvin; Van Pelt, Niels; Kerr, Andrew J

    2015-09-01

    Stress echocardiography is recommended for the assessment of asymptomatic patients with severe valvular heart disease (VHD) when there is discrepancy between symptoms and resting markers of severity. The aim of this study is to determine the prognostic value of exercise stress echocardiography in patients with common valve lesions. One hundred and fifteen patients with VHD (aortic stenosis (n=28); aortic regurgitation (n=35); mitral regurgitation, (n=26); mitral stenosis (n=26)), and age- and sex-matched controls (n=39) with normal ejection fraction underwent exercise stress echocardiography. The primary endpoint was a composite of death or hospitalization for heart failure. Asymptomatic VHD patients had lower exercise capacity than controls and 37% of patients achieved 60 mmHg) was associated with an increased risk of death or hospital admission (14% vs 1%, P<0.0001). The assessment of contractile reserve did not offer additional predictive value. In conclusion, an abnormal stress echocardiogram is associated with death and hospitalization with heart failure at 2 years. Stress echocardiography should be considered as part of the routine follow-up of all asymptomatic patients with VHD.

  12. Simulation for transthoracic echocardiography of aortic valve

    Science.gov (United States)

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  13. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  14. Digital echocardiography and telemedicine applications in pediatric cardiology.

    Science.gov (United States)

    Sable, Craig

    2002-01-01

    Digital echocardiography offers several advantages over videotape, including easy review, comparison, storage, postprocessing, and sharing of studies, quantitative analysis, and superior resolution. Newer echocardiography systems can write digital data to computer hardware, whereas older systems require digitization of analog data. Clinical and digital data compression is required to reduce study size. Clinical compression has been validated in several adult studies and one pediatric study. JPEG and MPEG digital compression ratios of 26:1 and 200:1, respectively, approximate S-videotape quality. JPEG is the DICOM 3.0 standard and is ideal for short loops, serial comparisons, and quantitative analysis. MPEG (the motion picture standard) lends itself to digitization of video streams and may be more attractive to pediatric cardiologists. Options for data storage and transfer range from limited local review to multiple offline review stations linked by a wide-area network. Telemedicine expands the capabilities of digital echocardiography in a "store and forward" or "real-time" format. Real-time neonatal telecardiology is accurate, impacts patient care, is cost-effective, and does not increase utilization. Cost, increased reliance on sonographers' skills, lack of accepted standards, and legal, licensure, and billing issues are obstacles to widespread acceptance of digital echocardiography and telemedicine.

  15. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  16. Recommendations for fetal echocardiography in twin pregnancy in 2016

    Directory of Open Access Journals (Sweden)

    Leszczyńska Katarzyna

    2016-01-01

    Full Text Available Progress in the fields of fetal cardiology and fetal surgery have been seen not only in singleton pregnancies but also in multiple pregnancies. Proper interpretation of prenatal echocardiography is critical to clinical decision making, family counseling and perinatal management for obstetricians, maternal fetal medicine specialists, neonatologists and pediatric cardiologists. Fetal echocardiography is one of the most challenging and time-consuming prenatal examinations to perform, especially in multiple gestations. Performing just the basic fetal exam in twin gestations may take an hour or more. Thus, it is not practical to perform this exam in all cases of multiple gestations. Therefore our review and recommendations are related to fetal echocardiography in twin gestation.

  17. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  18. Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Minardi Giovanni

    2006-09-01

    Full Text Available Abstract Background The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm in relatively aged patients at mean 24 months follow-up. Methods and results The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years. All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min. The following parameters were evaluated at rest and/or under DSE: heart rate (HR, ejection fraction (EF, cardiac output (CO, peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG, effective orifice area (EOA, indexed EOA (EOAi, left ventricular mass (LVM, indexed LVM (LVMi, Velocity Time Integral at left ventricular outflow tract (VTI LVOT and transvalvular (Aortic VTI, Doppler velocity index (DVI. At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm2 and 0.76 ± 0.2 cm2/m2; DVI was normal (0.50 ± 0.1. At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m2 to 191 ± 23.8g and 114.5 ± 10.6g/m2, respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg, MnPG (up to 43.2 ± 12.7mmHg. EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm2, 0.75 ± 0.3cm2/m2 and 0.48 ± 0.1 respectively. Two patients developed significant intraventricular gradients. Conclusion These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic

  19. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.

    Science.gov (United States)

    Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw

    2009-03-01

    To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed 50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

  20. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  1. Homogenization of Doppler broadening in spin-noise spectroscopy

    Science.gov (United States)

    Petrov, M. Yu.; Ryzhov, I. I.; Smirnov, D. S.; Belyaev, L. Yu.; Potekhin, R. A.; Glazov, M. M.; Kulyasov, V. N.; Kozlov, G. G.; Aleksandrov, E. B.; Zapasskii, V. S.

    2018-03-01

    The spin-noise spectroscopy, being a nonperturbative linear optics tool, is still reputed to reveal a number of capabilities specific to nonlinear optics techniques. The effect of the Doppler broadening homogenization discovered in this work essentially widens these unique properties of spin-noise spectroscopy. We investigate spin noise of a classical system—cesium atoms vapor with admixture of buffer gas—by measuring the spin-induced Faraday rotation fluctuations in the region of D 2 line. The line, under our experimental conditions, is strongly inhomogeneously broadened due to the Doppler effect. Despite that, optical spectrum of the spin-noise power has the shape typical for the homogeneously broadened line with a dip at the line center. This fact is in stark contrast with the results of previous studies of inhomogeneous quantum dot ensembles and Doppler broadened atomic systems. In addition, the two-color spin-noise measurements have shown, in a highly spectacular way, that fluctuations of the Faraday rotation within the line are either correlated or anticorrelated depending on whether the two wavelengths lie on the same side or on different sides of the resonance. The experimental data are interpreted in the frame of the developed theoretical model which takes into account both kinetics and spin dynamics of Cs atoms. It is shown that the unexpected behavior of the Faraday rotation noise spectra and effective homogenization of the optical transition in the spin-noise measurements are related to smallness of the momentum relaxation time of the atoms as compared with their spin-relaxation time. Our findings demonstrate abilities of spin-noise spectroscopy for studying dynamic properties of inhomogeneously broadened ensembles of randomly moving spins.

  2. Archeological Echocardiography: Digitization and Speckle-Tracking Analysis of Archival Echocardiograms in the HyperGEN Study

    Science.gov (United States)

    Aguilar, Frank G.; Selvaraj, Senthil; Martinez, Eva E.; Katz, Daniel H.; Beussink, Lauren; Kim, Kwang-Youn A.; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R.; Arnett, Donna K.; Shah, Sanjiv J.

    2015-01-01

    Background Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle-tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. Methods In the NHLBI HyperGEN study (N=2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter/intraobserver agreement was calculated. Accuracy was evaluated in (1) a separate second study (N=50) comparing prospective digital strain vs. post-hoc analog-to-digital strain; and (2) in a third study (N=95) comparing prospectively-obtained TDI e′ velocities with post-hoc STE e′ velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Results Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intraobserver agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post-hoc STE to prospective digital STE for strain analysis. STE-derived e′ velocities correlated with, but systematically underestimated, TDI e′ velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β =−2.4 [95% CI −3.6,−1.2]% per 1-SD increase in fasting glucose; Pechocardiography, the digitization and speckle-tracking analysis of archival echocardiograms, is feasible and generates parameters of cardiac mechanics similar to contemporary studies. PMID

  3. Development of left ventricular longitudinal speckle tracking echocardiography in very low birth weight infants with and without bronchopulmonary dysplasia during the neonatal period.

    Directory of Open Access Journals (Sweden)

    Christoph Czernik

    Full Text Available OBJECTIVES: In preterm infants, postnatal myocardial adaptation may be complicated by bronchopulmonary dysplasia (BPD. We aimed to describe the development of left ventricular function by serial 2D, Doppler, and speckle tracking echocardiography (2D-STE in infants with and without BPD during the neonatal period and compare these to anthropometric and conventional hemodynamic parameters. STUDY DESIGN: Prospective echocardiography on day of life (DOL 1, 7, 14, and 28 in 119 preterm infants 10% were seen for the apical segment. While anthropometric parameters show rapid development during the first 4 weeks of life, the speckle tracking parameters did not differ statistically significantly during the neonatal period. Infants with and without BPD differed significantly (p<0.001 in the development of anthropometric parameters, conventional hemodynamic parameters except for heart rate, and 2D-STE parameters: global longitudinal systolic strain rate (GLSSR and longitudinal systolic strain for the mid left wall (LSSR. The largest differences were seen at DOL 1 and 7 in GLSSR (p<0.001 and in LSSR (p<0.01. CONCLUSIONS: Reproducible 2D-STE measurements are possible in preterm infants <1500 g. Cardiac deformation reveals early (DOL 1 and 7 ventricular changes (GLSSR and LSSR in very low birth weight infants who develop BPD.

  4. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  5. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    OpenAIRE

    Miranda, Lavinia Pimentel; Camargos, Paulo Augusto Moreira; Torres, Rosália Morais; Meira, Zilda Maria Alves

    2014-01-01

    Background: Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. Objectives: To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. Methods: This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and ...

  6. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  7. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  8. Probability of malignancy in non-palpable thyroid nodules. Predictive value of color Doppler ultrasound and cytological correlation

    International Nuclear Information System (INIS)

    Perez Espinosa Sebastian; Pineda Ordonez, Diego; Garcia, Sandra; Costilla, Mariela

    2011-01-01

    Objective: To evaluate the diagnostic accuracy of ultrasound and Doppler criteria in the differentiation of malignant nodules, using cytological diagnosis as standard reference. Material and Method: Prospective observational study in 200 patients, between March-September 2008, assessed for known thyroid nodular disease using FNA. The probability of malignancy was categorized as low (0-3), intermediate (4-7) or high (greater than 7). The procedures were performed using Medison Sonoline ultrasound equipment, with a linear transducer (7.5 MHz), and the aspiration was performed with a 25 G needle and sent to cytology immediately. A single sample was needed in 88% of cases. Results: Approximately 96% of the nodules that went to cytology were categorized as low-grade, 3% as intermediate and 1% as high, without significant differences (p>0.5) when compared with the ultrasound score. Sonographic features indicating a high probability of malignancy were found in 2% (n=5) of cases, and the diagnosis was confirmed by cytology in 2 cases. Malignancy criteria such as size (>1 cm), irregular contours, solid echo structure, calcifications, and intranodal Doppler showed variable sensitivity and specificity (S: 32-44% and E: 28-55%) with overlapping confidence intervals within lesions of intermediate and low probability. Low probability lesions showed isoechogenicity, regular contours, lack of calcifications and intralesional Doppler, for a negative predictive value of 62-77%. Conclusion: Our results suggest that overlapping sonographic features between benign and malignant nodules requires final cytological diagnosis in most cases, given the safety of the cytological technique and the short waiting time.

  9. Simulation-based training in echocardiography.

    Science.gov (United States)

    Biswas, Monodeep; Patel, Rajendrakumar; German, Charles; Kharod, Anant; Mohamed, Ahmed; Dod, Harvinder S; Kapoor, Poonam Malhotra; Nanda, Navin C

    2016-10-01

    The knowledge gained from echocardiography is paramount for the clinician in diagnosing, interpreting, and treating various forms of disease. While cardiologists traditionally have undergone training in this imaging modality during their fellowship, many other specialties are beginning to show interest as well, including intensive care, anesthesia, and primary care trainees, in both transesophageal and transthoracic echocardiography. Advances in technology have led to the development of simulation programs accessible to trainees to help gain proficiency in the nuances of obtaining quality images, in a low stress, pressure free environment, often with a functioning ultrasound probe and mannequin that can mimic many of the pathologies seen in living patients. Although there are various training simulation programs each with their own benefits and drawbacks, it is clear that these programs are a powerful tool in educating the trainee and likely will lead to improved patient outcomes. © 2016, Wiley Periodicals, Inc.

  10. Exercise echocardiography in asymptomatic survivors of childhood cancer treated with anthracyclines

    DEFF Research Database (Denmark)

    Sieswerda, Elske; Kremer, Leontien C M; Vidmar, Suzanna

    2010-01-01

    BACKGROUND: Exercise echocardiography reveals abnormalities in asymptomatic childhood cancer survivors who previously have been treated with anthracyclines. We determined the added value of monitoring childhood cancer survivors with exercise echocardiography compared to monitoring with resting ec...

  11. Targeted neonatal echocardiography services: need for standardized training and quality assurance.

    LENUS (Irish Health Repository)

    Finan, Emer

    2014-10-01

    Targeted neonatal echocardiography refers to a focused assessment of myocardial performance and hemodynamics directed by a specific clinical question. It has become the standard of care in many parts of the world, but practice is variable, and there has been a lack of standardized training and evaluation to date. Targeted neonatal echocardiography was first introduced to Canada in 2006. The purpose of this study was to examine the characteristics of targeted neonatal echocardiography practice and training methods in Canadian neonatal intensive care units (NICUs).

  12. The diagnostic ability of echocardiography for infective endocarditis and its associated complications.

    Science.gov (United States)

    Vilacosta, Isidre; Olmos, Carmen; de Agustín, Alberto; López, Javier; Islas, Fabián; Sarriá, Cristina; Ferrera, Carlos; Ortiz-Bautista, Carlos; Sánchez-Enrique, Cristina; Vivas, David; San Román, Alberto

    2015-11-01

    Echocardiography, transthoracic and transoesophageal, plays a key role in the diagnosis and prognosis assessment of patients with infective endocarditis. It constitutes a major Duke criterion and is pivotal in treatment guiding. Seven echocardiographic findings are major criteria in the diagnosis of infective endocarditis (IE) (vegetation, abscess, pseudoaneurysm, fistulae, new dehiscence of a prosthetic valve, perforation and valve aneurysm). Echocardiography must be performed as soon as endocarditis is suspected. Transoesophageal echocardiography should be done in most cases of left-sided endocarditis to better define the anatomic lesions and to rule out local complications. Transoesophageal echocardiography is not necessary in isolated right-sided native valve IE with good quality transthoracic examination and unequivocal echocardiographic findings. Echocardiography is a very useful tool to assess the prognosis of patients with IE at any time during the course of the disease. Echocardiographic predictors of poor outcome include presence of periannular complications, prosthetic dysfunction, low left ventricular ejection fraction, pulmonary hypertension and very large vegetations.

  13. DOBUTAMINE STRESS-ECHOCARDIOGRAPHY: POSSIBILITY OF CLINICAL USAGE IN CARDIOLOGY PRACTICE

    Directory of Open Access Journals (Sweden)

    M. A. Saidova

    2016-01-01

    Full Text Available Currently stress-echocardiography or so-called burden echocardiography is essential method of patient examination to reveal latent ischemic heart disease (IHD. That is one of the mostly informative non-invasive methods of IHD diagnosis as well as efficacy evaluation of coronary angioplasty, surgical and pharmacological treatments of IHD. Dobutamine usage as a stress-agent at burden echocardiography allows evaluating not only ischemia but a myocardial vitality in post infarction area as well as clarify severity of valve stenosis, pulmonary hypertension and extent of latent obstruction of exhaust duct of the left ventricle. Method possibilities are presented as well as test protocol, main indications and contraindications.

  14. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice. © 2013, Wiley Periodicals, Inc.

  15. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  16. Aortic coarctation diagnosed by renal Doppler flow patterns in a hypertensive young patient: a case report

    International Nuclear Information System (INIS)

    Sari, S.; Kara, K.; Verim, S.

    2012-01-01

    Full text: Introduction: Aortic coarctation is a congenital malformation, which can cause systemic hypertension and subsequent complications, and causes of secondary hypertension, affecting in differential pressures in the upper and lower extremities. Because hypertension is caused by aortic coarctation, tends to be resistant to medical therapy, early recognition and surgical rectification are important. Objectives and tasks: In this article, we aimed to point out that renal Doppler sonography is a beneficial and frequently used to evaluate secondary hypertension, if there are bilateral tardus-parvus wave patterns are detected. Thus, bilateral renal artery stenosis, aortic stenosis, and coarctation should be considered in this condition. Materials and methods: A 23-year-old male who has six-month history of hypertension. He was referred by a cardiologist for investigation of his secondary hypertension. There was an ascending aortic dilatation, left ventricular hypertrophy in his echocardiography. Results: The patient's blood pressure was measured as 160/90 mm Hg in his both arms. Renal Doppler sonography was performed to identify the potential cause of secondary hypertension, specifically renal artery stenosis, after tardus-parvus pulse waves were noted in both renal intralobar-arteries. Aortic coarctation is suspected and then a chest computed tomography (CT) was performed to evaluate supra-diaphragmatic vessel abnormalities. The CT exposed a stenotic lesion in the isthmus of the aorta. The patient was transferred to cardiovascular surgery department for treatment. Conclusion: Careful physical examination should be performed in all hypertensive patients. If bilateral tardus-parvus wave pattern are seen in patients who has been referred for Doppler evaluation on suspicion of renovascular hypertension, aortic coarctation should be considered as differential diagnosis

  17. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  18. Comprasion of ovarian stromal blood flow measured by color Doppler ultrasonography in polycystic ovary syndrome patients and healthy women with ultrasonographic evidence of polycystic.

    Science.gov (United States)

    Ozdemir, Ozhan; Sari, Mustafa Erkan; Kalkan, Dilek; Koc, Esra Meltem; Ozdemir, Seyda; Atalay, Cemal Resat

    2015-04-01

    To compare ovarian stromal artery blood flows measured by Doppler ultrasonography of polycystic ovary syndrome (PCOS) patients and healthy women with polycystic ovarian image in ultrasonography. Forty-two patients diagnosed with PCOS according to the criteria of 2003 Rotterdam Concencus Conferance on PCOS and 38 healthy volunteers with polycystic ovarian image in ultrasonography were included in the study. Ovarian volumes and ovarian stromal artery blood flows were measured by 3-dimensional (3-D) ultrasonography and Doppler ultrasonography in all patients. In patients with PCOS, ovarian stromal artery pulsatility index (PI) and resistivity index (RI) were found significantly different from healthy women with polycystic ovarian image in ultrasonography (p ovarian volumes were found significantly higher in patients with PCOS (p ovarian volumes and ovarian stromal artery resistivity indices. Ovarian stromal artery Doppler examination could have an importance to explain the pathophysiology of PCOS, but there are few publications in the literature about PCOS and the details of ovarian stromal artery Doppler parameters in patients with polycystic ovarian image only. We conclude that Doppler ultrasonography findings of PCOS patients might be helpful in understanding the clinical follow-up and etiology of the disease.

  19. Modificações da hemodinâmica fetal pelo estímulo sonoro: avaliação pela dopplervelocimetria colorida Vibro-acoustic stimulation induced hemodynamic fetal changes assessed by color doppler

    Directory of Open Access Journals (Sweden)

    Francisco Mauad Filho

    1999-04-01

    Full Text Available Objetivos: verificar se ocorrem ou não alterações hemodinâmicas na aréria cerebral média (ACM aferido pela dopplervelocimetria colorida após realização de um estímulo sonoro. Métodos: trinta fetos de gestantes consideradas clinicamente normais com idade gestacional igual ou superior a 28 semanas foram submetidos a um estímulo sonoro. Examinamos as alterações da velocidade sangüínea na ACM fetal por meio do índice de resistência e da freqüência cardíaca fetal, pelo doppler colorido, antes e depois do estímulo acústico. Resultados: a média da freqüência cardíaca fetal (FCF antes do estímulo sonoro foi de 142,41 batimentos por minuto (bpm com desvio padrão de 9,01 e faixa de variação de 122 a 162 bpm. Após o estímulo sonoro, a média da FCF foi de 159,44 bpm com desvio padrão de 15,49, com faixa de variação de 130 a 187 bpm (pPurpose: to determine the possible occurrence of hemodynamic changes in the middle cerebral artery of the fetus (MCA using color doppler after vibro-acoustic stimulation. Methods: thirty fetuses from pregnant women considered to be clinically normal, with a gestational age of 28 weeks or more were submitted to vibro-acoustic stimulation. We examined the changes in blood flow rate in the middle cerebral artery of the fetus on the basis of resistance index (RI and fetal heart rate (FHR by color doppler before and after the sound stimulus. Results: mean FHR before vibro-acoustic stimulation was 142.41 beats per minute (bpm with a standard deviation of 9.01 and a range of 122 to 162 bpm. After stimulation, mean FHR was 159.44 bpm with a standard deviation of 15.49 and a range of 130 to 187 bpm (p<0.01. Mean RI in the MCA of the fetuses was 75.89% (range: 64 to 91% before the experiment. After the vibro-acoustic stimulation, mean RI was 66.93% (range: 47 to 83%; p < 0.01. Conclusions: we observed that a sound stimulus provokes the well-known immediate and significant elevation of FHR and a

  20. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  1. Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography: A New Alternative in the Assessment of the Segmental Ventricular Function

    Directory of Open Access Journals (Sweden)

    Silva Carlos Eduardo Suaide

    2002-01-01

    Full Text Available OBJECTIVE: Doppler tissue imaging (DTI enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male with ages ranging from 12 to 59 years (32.9 ± 10.6. Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls were respectively, in cm/s, 7.35(1.64, 5.26(1.88, and 3.33(1.58 in systole and 10.56(2.34, 7.92(2.37, and 3.98(1.64 in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms, and diastolic was 459.18ms (±18.13ms based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05. The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.

  2. A guideline update for the practice of echocardiography in the cardiac screening of sports participants: a joint policy statement from the British Society of Echocardiography and Cardiac Risk in the Young

    Directory of Open Access Journals (Sweden)

    David Oxborough PhD

    2018-03-01

    Full Text Available Sudden cardiac death (SCD in an athlete is a rare but tragic event. In view of this, pre-participation cardiac screening is mandatory across many sporting disciplines to identify those athletes at risk. Echocardiography is a primary investigation utilized in the pre-participation setting and in 2013 the British Society of Echocardiography and Cardiac Risk in the Young produced a joint policy document providing guidance on the role of echocardiography in this setting. Recent developments in our understanding of the athlete’s heart and the application of echocardiography have prompted this 2018 update.

  3. ECHOCARDIOGRAPHY BASED STUDY OF THE PREVALENCE AND PATTERN OF CONGENITAL HEART DISEASE (CHD IN 5-15 YEARS OLD SCHOOL GOING CHILDREN OF MANIPUR, A NORTH-EAST HILLY INDIAN STATE

    Directory of Open Access Journals (Sweden)

    Rajendra Singh Thangjam

    2017-12-01

    Full Text Available BACKGROUND CHD is the leading cause of morbidity and mortality in the developed world, while reports from India looking into the burden of the disease have been variable depending on the age group of subjects studied and the methodology involved. We were interested to find the prevalence and pattern of the disease in this north eastern Indian state of Manipur, which has a unique geographical and racial composition. MATERIALS AND METHODS This is a community based, prospective, cross sectional study where each and every child aged 5-15 years from randomly selected schools of Manipur were examined by 2D colour Doppler Echocardiography and physically as well, where the examiners were blinded, and the findings were noted independent of each other. The anthropometric parameters, clinical details and echocardiography findings were all recorded. RESULTS Of the 3600 children examined, 47 cases of CHD were detected, giving echocardiographic prevalence of 13 per 1000 where BAV (44% was found as the commonest lesion followed by VSD (17% and ASD (14%. Clinically detectable lesion was found in 21 subjects (VSD -8, ASD-7, PS-3, PDA -1, AVSD-1, BAV-1 with AR. Of the clinically detectable CHD, VSD was the commonest followed by ASD. In the subclinical CHD category, 20 cases of BAV, 4 cases of mild MVP without MR, 1 case of apical LV discompacta, 1 case of IASA were detected. CONCLUSION The echocardiography prevalence of congenital heart disease in school going children of Manipur is 13/1000. This highest ever reported prevalence of CHD in children is most probably related to the use of the highly sensitive investigative tool of Echocardiography in each subject of our study resulting in detection of clinically silent lesions.

  4. Evaluation of echocardiography in the management of elderly patients with heart failure.

    Science.gov (United States)

    Hendry, A; Hacking, L; Langhorne, P; Vallance, R; MacDonald, J

    1999-09-01

    To determine the validity of a clinical diagnosis of systolic dysfunction in elderly patients with heart failure and assess the contribution of echocardiography to their management. 61 elderly patients with a diagnosis of heart failure in a geriatric assessment unit setting. Prospective study determining sensitivity, specificity and predictive values of a clinical and radiological diagnosis compared with echocardiographic standard. Proposed management was compared before and after echocardiography. Clinical assessment was highly sensitive (93%) but lacked specificity (32%). Combining radiological and clinical diagnoses increased specificity to 58%. Echocardiography revised the lead cardiac diagnosis for 28% of patients and influenced patient management plans for 41%. For elderly patients with heart failure, echocardiography improves diagnostic accuracy and identifies those patients with potential to benefit from angiotensin-converting enzyme inhibitors.

  5. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  6. Echocardiography in patients with complications related to pacemakers and cardiac defibrillators.

    Science.gov (United States)

    Almomani, Ahmed; Siddiqui, Khadija; Ahmad, Masood

    2014-03-01

    The evolving indications and uses for implantable cardiac devices have led to a significant increase in the number of implanted devices each year. Implantation of endocardial leads for permanent pacemakers and cardiac defibrillators can cause many delayed complications. Complications may be mechanical and related to the interaction of the device leads with the valves and endomyocardium, e.g., perforation, infection, and thrombosis, or due to the electrical pacing of the myocardium and conduction abnormalities, e.g., left ventricular dyssynchrony. Tricuspid regurgitation, another delayed complication in these patients, may be secondary to both mechanical and pacing effects of the device leads. Echocardiography plays an important role in the diagnosis of these device-related complications. Both two-dimensional transthoracic echocardiography and transesophageal echocardiography provide useful diagnostic information. Real time three-dimensional echocardiography is a novel technique that can further enhance the detection of lead-related complications. © 2013, Wiley Periodicals, Inc.

  7. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  8. Visualization of traumatic tricuspid insufficiency by three-dimensional echocardiography.

    Science.gov (United States)

    Nishimura, Kazuhisa; Okayama, Hideki; Inoue, Katsuji; Saito, Makoto; Nagai, Takayuki; Suzuki, Jun; Ogimoto, Akiyoshi; Ohtsuka, Tomoaki; Higaki, Jitsuo

    2010-01-01

    A 19-year-old male was admitted to the emergency room of our hospital after a motor vehicle accident. During his first physical examination, a holosystolic murmur was heard at the fourth left parasternal border. Transthoracic echocardiography showed severe tricuspid insufficiency, but the cause of tricuspid insufficiency was unclear. Therefore, three-dimensional echocardiography was performed and demonstrated flail anterior, posterior and septal leaflets of the tricuspid valve. The diagnosis was tricuspid insufficiency due to papillary muscle rupture secondary to chest blunt trauma. Surgical repair of the tricuspid valve was performed in this patient. After surgery, the signs and symptoms of right ventricular heart failure were relieved. In this case, three-dimensional echocardiography was very useful for the evaluation of spatial destruction of the tricuspid valve and papillary muscle. 2009 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    Science.gov (United States)

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.

  10. Usefulness of exercise echocardiography in ischemic heart disease. Comparison with exercise cardiac scintigraphy

    International Nuclear Information System (INIS)

    Tashiro, Hideki; Koyanagi, Samon; Narabayashi, Hideki; Inou, Tetsuji; Takeshita, Akira

    1999-01-01

    Exercise echocardiography and exercise thallium-201 ( 201 Tl) single photon emission computed tomography (SPECT) were performed in 152 patients with suspected coronary artery disease, including 61 patients with old myocardial infarction. All patients underwent coronary arteriography, and coronary artery disease was defined as ≥75% diameter stenosis. Digital two-dimensional echocardiography was performed before and after the treadmill exercise test, and wall motion abnormality was evaluated using quad-screen. Sensitivity and specificity for the diagnosis of coronary artery disease were similar for the 2 exercise tests (77% and 80% for echocardiography and 75%, and 83% for SPECT, respectively). Diagnoses for one-vessel disease, 2-vessel disease and 3-vessel disease were similar for echocardiography (79%, 72% and 77%, respectively) and SPECT (74%, 75% and 77%, respectively). Sensitivity for the diagnosis of ischemia at the area remote from infarct area was low for both exercise echocardiography and exercise SPECT (45% and 48%, respectively). Exercise echocardiography has comparable diagnostic value to SPECT for the detection of coronary artery disease. However, both exercise tests have limitations for the diagnosis of ischemia at the area remote from infarct area. (author)

  11. Three-dimensional transesophageal echocardiography of the atrial septal defects

    Directory of Open Access Journals (Sweden)

    Romero-Cárdenas Ángel

    2008-07-01

    Full Text Available Abstract Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

  12. Factors associated with diagnostic discrepancy for left ventricular hypertrophy between electrocardiography and echocardiography

    DEFF Research Database (Denmark)

    Sandager Petersen, Søren; Reinholdt Pedersen, Line; Pareek, Manan

    2017-01-01

    (absolute value/cut-off value for LVH) were used as outcome variables in order to identify explanatory variables associated with diagnostic discrepancies between ECG and echocardiography. RESULTS: Of the 1382 subjects included, 77% did not display any signs of LVH, 6% had LVH defined by ECG only, 13% had...... LVH defined by echocardiography only, and 5% had LVH on both ECG and echocardiography. Older subjects and those with higher blood pressure and RWT were more likely to have a relatively greater LVMI on echocardiography than that predicted on ECG (odds ratio: 1.65 per 10 years (95% confidence interval...... and odds ratio: 1.41 (95% CI: 1.06-1.87), p = .02), but FPG did not independently influence discrepancy between ECG and echocardiography. CONCLUSION: Age, blood pressure, female sex, greater RWT and use of antihypertensive medication were associated with a greater risk of non-consistency between LVH...

  13. Bedside Echocardiography for Rapid Diagnosis of Malignant Cardiac Tamponade

    Directory of Open Access Journals (Sweden)

    Alaina Brinley

    2017-01-01

    Full Text Available History of present illness: A 47-year-old female with metastatic breast cancer presented to the Emergency Department with chest pain and shortness of breath. She was hypotensive and her EKG showed sinus tachycardia with low voltage. A bedside ultrasound was performed that detected a pericardial effusion and evidence of cardiac tamponade. The patient’s vitals improved with a fluid bolus and she went emergently to the cardiac catheterization lab for fluoroscopy and echocardiography guided pericardiocentesis. A total of 770 mL of fluid was removed from her pericardial space. Significant findings: The video shows a subxiphoid view of the heart with evidence of a large pericardial effusion with tamponade – note the anechoic stripe in the pericardial sac (see red arrow. This video demonstrates paradoxical right ventricular collapse during diastole and right atrial collapse during systole which is indicative of tamponade.1,2 Figure 1 is from the same patient and shows sonographic pulsus paradoxus. This is an apical 4 chamber view of the heart with the sampling gate of the pulsed wave doppler placed over the mitral valve. The Vpeak max and Vpeak min are indicated. If there is more than a 25% difference with inspiration between these 2 values, this is highly suggestive of tamponade.1 In this case, there is a 32.4% difference between the Vpeak max 69.55 cm/s and Vpeak min 46.99 cm/s. Discussion: Cardiac tamponade is distinguished from pericardial effusion by right ventricular compression/collapse and hemodynamic instability. Findings can include hypotension, tachycardia, distant heart sounds, and jugular venous distension.3,4 One might also see a plethoric IVC without respiratory variation indicative of elevated right atrial pressures.1 Detection of right ventricular collapse for cardiac tamponade has sensitivities ranging from 48%-100% and specificities ranging from 33%-100%.5 A larger effusion is more likely to lead to cardiac tamponade. However

  14. Correlation between the tissue Doppler, strain rate, strain imaging during the dobutamine infusion and coronary fractional flow reserve during catheterization: a comparative study.

    Science.gov (United States)

    Dagdelen, Sinan; Yuce, Murat; Emiroglu, Yunus; Ergelen, Mehmet; Pala, Selcuk; Tanalp, Ali Cevat; Izgi, Akin; Kirma, Cevat

    2005-06-22

    Coronary fractional flow reserve (FFR) as an invasive, and dobutamine stress echocardiography (DSE) as a noninvasive technique were used to detect critical coronary stenosis. This study was undertaken to assess correlation between these two techniques by using tissue Doppler, strain rate (SR), and strain imaging (S). In 17 patients (aged 54.9+/-12.6, 4 F), a total of 22 vessels were studied. On dobutamine stress echocardiography, baseline and peak systolic (Sm), early (Em) and late (Am) diastolic myocardial velocities, SR and S were recorded from parasternal view (mid-posterior segment) for radial and apical view (mid-septum) for longitudinal deformation. Then coronary FFR was performed by using intracoronary adenosine infusion, and the value of system were analyzed for longitudinal SR and S values, it had a mild correlation with SR (r = 0.47, p = 0.044) and a good correlation with S (r = 0.66, p = 0.002). The quantification of regional myocardial deformation by using DSE rather than the motion would be more appropriate in detecting the ischemic dysfunctional segment supplied by the critical coronary stenosis. Strain measurement during the dobutamine infusion may provide an information on the FFR results of the culprit vessel.

  15. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  16. A method to validate quantitative high-frequency power doppler ultrasound with fluorescence in vivo video microscopy.

    Science.gov (United States)

    Pinter, Stephen Z; Kim, Dae-Ro; Hague, M Nicole; Chambers, Ann F; MacDonald, Ian C; Lacefield, James C

    2014-08-01

    Flow quantification with high-frequency (>20 MHz) power Doppler ultrasound can be performed objectively using the wall-filter selection curve (WFSC) method to select the cutoff velocity that yields a best-estimate color pixel density (CPD). An in vivo video microscopy system (IVVM) is combined with high-frequency power Doppler ultrasound to provide a method for validation of CPD measurements based on WFSCs in mouse testicular vessels. The ultrasound and IVVM systems are instrumented so that the mouse remains on the same imaging platform when switching between the two modalities. In vivo video microscopy provides gold-standard measurements of vascular diameter to validate power Doppler CPD estimates. Measurements in four image planes from three mice exhibit wide variation in the optimal cutoff velocity and indicate that a predetermined cutoff velocity setting can introduce significant errors in studies intended to quantify vascularity. Consistent with previously published flow-phantom data, in vivo WFSCs exhibited three characteristic regions and detectable plateaus. Selection of a cutoff velocity at the right end of the plateau yielded a CPD close to the gold-standard vascular volume fraction estimated using IVVM. An investigator can implement the WFSC method to help adapt cutoff velocity to current blood flow conditions and thereby improve the accuracy of power Doppler for quantitative microvascular imaging. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    2016-01-01

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  18. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  19. Strain Echocardiography Improves Risk Prediction of Ventricular Arrhythmias After Myocardial Infarction

    DEFF Research Database (Denmark)

    Haugaa, Kristina H; Grenne, Bjørnar L; Eek, Christian H

    2013-01-01

    The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI).......The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI)....

  20. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.