WorldWideScience

Sample records for echocardiographic method-a clinical

  1. Left ventricular noncompaction: Clinical-echocardiographic study

    Directory of Open Access Journals (Sweden)

    Nikolić Aleksandra

    2012-01-01

    Full Text Available Background/Aim. Left ventricular noncompaction (LVNC is a disorder in endomyocardial morphogenesis, seen either isolated (in the absence of other cardiac anomalies or in association with congenital heart disease and some neuromuscular diseases. Intrauterine arrest of the compaction of myocardial fibers is postulated to be the reason of LVNC. Recognition of this condition is extremely important due to its high mortality and morbidity that lead to progressive heart failure, ventricular arrhythmias and thromboembolic events. The aim of this study was to determine the prevalence and clinical presentation of LVNC among consecutive outpatients according to clinical and echocardiographyic findings. Methode. A total of 3,854 consecutive patients examined at the Institute for Cardiovascular Diseases within a period January 2006 - January 2007 were included in the study. All the patients underwent echocardiographic examination using the same equipment (Vivid 7, GE Medical System. Echocardiographic parameters and clinical presentation in patients with echocardiographic criteria for LVNC were analyzed. Results. Analyzing 3,854 consecutive outpatients, using two-dimensional Color Doppler echocardiography from January 2006 to January 2007, 12 patients met the criteria for LVNC. Seven of them were male. The mean age at diagnosis was 45 ± 15 years. Analyzing clinical manifestation of LVNC it was found that seven patients had signs of heart failure, six had arrhythmias with no embolic events. Conclusion. Our results suggest that the real prevalence of LVNC may be higher than expected. New studies have to be done to solve this problem.

  2. Clinical Electrocardiographic and Echocardiographic Features of ...

    African Journals Online (AJOL)

    Clinical Electrocardiographic and Echocardiographic Features of Atrial Fibrillation in Nigerians: An Analysis of 39 Patients Seen at the Lagos University Teaching Hospital. ... Congestive cardiac failure was present in 74% of the subjects with a mean NYHA class of about III. Embolic phenomenon was observed in 15% of the ...

  3. Clinical Outcome of Degenerative Mitral Regurgitation: Critical Importance of Echocardiographic Quantitative Assessment in Routine Practice.

    Science.gov (United States)

    Antoine, Clemence; Benfari, Giovanni; Michelena, Hector I; Malouf, Joseph F; Nkomo, Vuyisile T; Thapa, Prabin; Enriquez-Sarano, Maurice

    2018-05-31

    Background -Echocardiographic quantitation of degenerative mitral regurgitation (DMR) is recommended whenever possible in clinical guidelines but is criticized and its scalability to routine clinical practice doubted. We hypothesized that echocardiographic DMR quantitation, performed in routine clinical practice by multiple practitioners predicts independently long-term survival, and thus is essential to DMR management. Methods -We included patients diagnosed with isolated mitral-valve-prolapse 2003-2011 and any degree of MR quantified by any physician/sonographer in routine clinical practice. Clinical/echocardiographic data acquired at diagnosis were retrieved electronically. Endpoint was mortality under medical treatment analyzed by Kaplan-Meir method and Proportional-Hazard models. Results -The cohort included 3914 patients (55% male) aged 62±17 years, with left ventricular ejection fraction (LVEF) 63±8% and routinely measured effective regurgitant orifice area (EROA) 19[0-40] mm 2 During follow-up (6.7±3.1 years) 696 patients died under medical management and 1263 underwent mitral surgery. In multivariate analysis, routinely measured EROA was associated with mortality (adjusted-hazard-ratio 1.19[1.13-1.24] p 40 mm 2 threshold. Conclusions -Echocardiographic DMR quantitation is scalable to routine practice and is independently associated with clinical outcome. Routinely measured EROA is strongly associated with long-term survival under medical treatment. Excess mortality vs. the general population appears in the "moderate" DMR range and steadily increases with higher EROA. Hence, individual EROA values should be integrated into therapeutic considerations, additionally to categorical DMR grading.

  4. Atrial Fibrillation Ablation in Systolic Dysfunction: Clinical and Echocardiographic Outcomes

    Directory of Open Access Journals (Sweden)

    Tasso Julio Lobo

    2015-01-01

    Full Text Available Background: Heart failure and atrial fibrillation (AF often coexist in a deleterious cycle. Objective: To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF ablation. Methods: Patients with ventricular systolic dysfunction [ejection fraction (EF <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class and echocardiographic (EF, left atrial diameter data were compared (McNemar test and t test before and after ablation. Results: 31 patients (6 women, 25 men, aged 37 to 77 years (mean, 59.8±10.6, underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%. During a mean follow-up of 20.3±17 months, 24 patients (77% were in sinus rhythm, 11 (35% being on amiodarone. Eight patients (26% underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures. Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001. The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005 and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026. No major complications occurred. Conclusion: Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.

  5. Clinical and echocardiographic features of aorto-atrial fistulas

    Directory of Open Access Journals (Sweden)

    Ananthasubramaniam Karthik

    2005-01-01

    Full Text Available Abstract Aorto-atrial fistulas (AAF are rare but important pathophysiologic conditions of the aorta and have varied presentations such as acute pulmonary edema, chronic heart failure and incidental detection of the fistula. A variety of mechanisms such as aortic dissection, endocarditis with pseudoaneurysm formation, post surgical scenarios or trauma may precipitate the fistula formation. With increasing survival of patients, particularly following complex aortic reconstructive surgeries and redo valve surgeries, recognition of this complication, its clinical features and echocardiographic diagnosis is important. Since physical exam in this condition may be misleading, echocardiography serves as the cornerstone for diagnosis. The case below illustrates aorto-left atrial fistula formation following redo aortic valve surgery with slowly progressive symptoms of heart failure. A brief review of the existing literature of this entity is presented including emphasis on echocardiographic diagnosis and treatment.

  6. Cardiovascular abnormalities in patients with oral cleft: a clinical-electrocardiographic-echocardiographic study

    Directory of Open Access Journals (Sweden)

    Gisele C.P. Leite

    2018-04-01

    Full Text Available OBJECTIVES: The present study aims to describe the clinical, electrocardiographic, and echocardiographic cardiological findings in a group of patients with oral clefts. METHODS: This is a prospective cross-sectional study on 70 children (age range from 13 days to 19 years with oral clefts who attended the multidisciplinary program of a university hospital from March 2013 to September 2014. The patients were evaluated by a pediatric cardiologist and underwent detailed anamnesis, physical examination, electrocardiogram, and echocardiogram. RESULTS: Sixty percent of the patients were male; 55.7% presented with cleft lip and palate, and 40.0% presented with health complaints. Comorbidities were found in 44.3%. Relevant pregnancy, neonatal, family and personal antecedents were present in 55.7%, 27.1%, 67.2%, and 24.3% of the patients, respectively. Regarding the antecedents, 15.2% of the patients presented with a cardiac murmur, 49.0% with a familial risk of developing plurimetabolic syndrome, and 6% with family antecedents of rheumatic fever. Electrocardiographic evaluation showed one case of atrioventricular block. Echocardiograms were abnormal in 35.7% of the exams, including 5 cases of mitral valve prolapse — one of which was diagnosed with rheumatic heart disease. CONCLUSION: The finding of a family risk of developing plurimetabolic syndrome and a diagnosis of rheumatic heart disease indicates that patients with oral clefts may be more prone to developing acquired heart disease. Thus, our findings highlight the importance of anamnesis and methodological triangulation (clinical-electrocardiographic-echocardiographic in the investigation of patients with oral clefts and emphasize that cardiological follow-up to evaluate acquired and/or rhythm heart diseases is necessary. This strategy permits comorbidity prevention and individualized planned treatment.

  7. Echocardiographic and clinical outcomes of central versus noncentral percutaneous edge-to-edge repair of degenerative mitral regurgitation

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Franzen, Olaf; Winter, Reidar

    2013-01-01

    This study aimed to assess the clinical and echocardiographic results of MitraClip implantation in noncentral degenerative mitral regurgitation (dMR) compared with central dMR.......This study aimed to assess the clinical and echocardiographic results of MitraClip implantation in noncentral degenerative mitral regurgitation (dMR) compared with central dMR....

  8. Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical Experience.

    Science.gov (United States)

    Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J

    2016-06-01

    There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  9. Effect of advanced chronic kidney disease in clinical and echocardiographic outcomes of patients treated with MitraClip system

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Settergren, Magnus; Pighi, Michele

    2015-01-01

    BACKGROUND: Data regarding the influence of different levels of renal dysfunction on clinical and echocardiographic results of MitraClip therapy are scarce. We aimed to evaluate the impact of baseline advance renal failure in the outcomes of a cohort of patients treated with MitraClip. METHODS AN...

  10. Clinical and echocardiographic findings of patients with suspected acute pulmonary thromboembolism who underwent computed tomography pulmonary angiography

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2016-01-01

    Full Text Available Background: The aim of the study was to determine the correlation between clinical and echocardiographic findings and risk factors of patients with suspected acute pulmonary thromboembolism (PTE who underwent computed tomography pulmonary angiography (CTPA. Materials and Methods: In this cross-sectional study, 310 hospitalized patients aged >18 years with high clinical suspicion of PTE referred to imaging center of our hospital from different wards for CTPA were enrolled. The frequency of different clinical presentations, risk factors, items of Wells' criteria, and echocardiographic findings was compared in patients with and without PTE, which have been diagnosed according to the CTPA results. Results: PTE was diagnosed in 53 (17.1% of patients with suspected PTE. From clinical manifestations, tachypnea, pleuritic chest pain, and edema of lower extremities were significantly more frequent among patients with PTE (P < 0.05. Major surgery was the risk factor which was significantly more prevalent among patients with PTE (P < 0.05. Frequency of all criteria of Wells' criteria, except hemoptysis, was significantly higher in patients with PTE (P < 0.05. The frequency of all studied echocardiographic variables was significantly higher in patients with PTE (P < 0.05. Conclusion: It is suggested that we could use the results of this study for utilizing the diagnostic process of PTE in patients with highly clinical suspicion of PTE and providing more validated decision. Using the results of this study, we could identify high-risk patients and made appropriate risk assessment for better management of patients with suspected PTE as well as reduce the rate of unnecessary CTPA and its related adverse consequences.

  11. Incidence of mitral valve prolapse in one hundred clinically stable newborn baby girls: an echocardiographic study.

    Science.gov (United States)

    Chandraratna, P A; Vlahovich, G; Kong, Y; Wilson, D

    1979-09-01

    Clinical and echocardiographic examinations were performed on 100 clinically stable, newborn baby girls. Mitral valve prolapse was noted on the echocardiograms of seven babies. Three subjects had systolic clicks, two of whom had systolic murmurs following the click. The four other babies who had echocardiographic evidence of mitral valve prolapse had no abnormal auscultatory signs. Of the 93 babies without evidence of mitral prolapse, 91 had normal echocardiograms and auscultatory features; one was noted to have a murmur consistent with a ventricular septal defect, and another had an eccentric aortic valve on the echocardiogram which was suggestive of a bicuspid aortic valve. Serial studies on our group of subjects will yield useful information regarding the natural history of mitral valve prolapse.

  12. Echocardiographic Assessment of Heart Valve Prostheses

    Science.gov (United States)

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  13. Echocardiographic evaluation of thalassemia intermedia patients in Duhok, Iraq.

    Science.gov (United States)

    Mohammad, Ameen Mosa

    2014-12-11

    Cardiac complications are among the most serious problems of thalassemia intermedia patients. The current study was initiated to address the latter issue through the study of the echocardiographic findings and correlate it with clinical characteristics of thalassemia intermedia patients in Duhok, Kurdistan region, Iraq. An echocardiographic assessment of 61 beta-thalassemia intermedia cases was performed. It included 30 males and 31 females, with a mean age 19.6 ± 7.5 years. The standard echostudy of two-dimension and M-mode measurements of cardiac chambers were done. The continuous doppler regurgitant jet of tricuspid and pulmonary valves were recorded. Left ventricle diastolic function was assessed by pulsed doppler of mitral valve inflow. To correlate the clinical with echocardiographic findings, patients were divided, according to tricuspid regurgitant velocity, into three groups (intermedia patients. Therapeutic trails targeting these complications are indicated, and echocardiographic assessment is necessary to be offered early for thalassemia intermedia.

  14. Chronic valvular disease: correlation between clinical, electrocardiographic, radiographic and echocardiographic aspects in dogs

    International Nuclear Information System (INIS)

    Soares, E.C.; Larsson, M.H.M.A.; Yamato, R.J.

    2005-01-01

    Echocardiographic aspects of chronic mitral valvular disease were studied and compared to physical, radiographic and electrocardiographic aspects. Seventy dogs were used, and clinical examination, thoracic radiography, electrocardiogram and echocardiogram were performed. Correlations between regurgitation severity with cardiac failure functional class and murmur intensity were observed. The electrocardiogram showed a low sensibility in detecting cardiac chamber enlargement, caused by mitral regurgitation. All the dogs with severe mitral regurgitation showed cardiomegaly according to thoracic radiographies

  15. Echocardiographic evaluation during weaning from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Luciele Medianeira Schifelbain

    2011-01-01

    Full Text Available INTRODUCTION: Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. OBJECTIVES: To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T-tube; and comparing patient subgroups: success vs. failure in weaning. METHODS: Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T-tube. Pressure support ventilation vs. T-tube and weaning success vs. failure were compared using ANOVA and Student's t-test. The level of significance was p<0.05. RESULTS: Twenty-four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T-tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. CONCLUSION: No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T-tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients

  16. Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g

    OpenAIRE

    Visconti, Luiza Fortunato; Morhy, Samira Saady; Deutsch, Alice D'Agostini; Tavares, Gl?ucia Maria Penha; Wilberg, Tatiana Jardim Mussi; Rossi, Felipe de Souza

    2013-01-01

    ABSTRACT Objective: To identify clinical and echocardiographic parameters associated with the evolution of the ductus arteriosus in neonates with birth weight lower than 1,500g. Methods: Retrospective study of 119 neonates in which clinical parameters (Prenatal: maternal age, risk of infection and chorioamnionitis, use of corticosteroid, mode of delivery and gestational age. Perinatal: weight, Apgar score, gender and birth weight/gestational age classification; Postnatal: use of surfactant, s...

  17. A meta-analysis of echocardiographic measurements of the left heart for the development of normative reference ranges in a large international cohort

    DEFF Research Database (Denmark)

    Møgelvang, Rasmus

    2014-01-01

    , from multiple studies around the world. METHODS AND RESULTS: The Echocardiographic Normal Ranges Meta-Analysis of the Left heart (EchoNoRMAL) collaboration was established and population-based data sets of echocardiographic measurements combined to perform an individual person data meta-analysis. Data...... from 43 studies were received, representing 51 222 subjects, of which 22 404 adults aged 18-80 years were without clinical cardiovascular or renal disease, hypertension or diabetes. Quantile regression or an appropriate parametric regression method will be used to derive reference values at the 5th...

  18. Two-dimensional echocardiographic features of right ventricular infarction

    International Nuclear Information System (INIS)

    D'Arcy, B.; Nanda, N.C.

    1982-01-01

    Real-time, two-dimensional echocardiographic studies were performed in 10 patients with acute myocardial infarction who had clinical features suggestive of right ventricular involvement. All patients showed right ventricular wall motion abnormalities. In the four-chamber view, seven patients showed akinesis of the entire right ventricular diaphragmatic wall and three showed akinesis of segments of the diaphragmatic wall. Segmental dyskinetic areas involving the right ventricular free wall were identified in four patients. One patient showed a large right ventricular apical aneurysm. Other echocardiographic features included enlargement of the right ventricle in eight cases, paradoxical ventricular septal motion in seven cases, tricuspid incompetence in eight cases, dilation of the stomach in four cases and localized pericardial effusion in two cases. Right ventricular infarction was confirmed by radionuclide methods in seven patients, at surgery in one patient and at autopsy in two patients

  19. Clinical and echocardiographic characteristics associated with the evolution of the ductus arteriosus in the neonate with birth weight lower than 1,500g.

    Science.gov (United States)

    Visconti, Luiza Fortunato; Morhy, Samira Saady; Deutsch, Alice D'Agostini; Tavares, Gláucia Maria Penha; Wilberg, Tatiana Jardim Mussi; Rossi, Felipe de Souza

    2013-01-01

    To identify clinical and echocardiographic parameters associated with the evolution of the ductus arteriosus in neonates with birth weight lower than 1,500g. Retrospective study of 119 neonates in which clinical parameters (Prenatal: maternal age, risk of infection and chorioamnionitis, use of corticosteroid, mode of delivery and gestational age. Perinatal: weight, Apgar score, gender and birth weight/gestational age classification; Postnatal: use of surfactant, sepsis, fluid intake, heart murmur, heart rate, precordial movement and pulses, use of diuretics, oxygenation index, desaturation/apnea, ventilatory support, food intolerance, chest radiography, renal function, hemodynamic instability, and metabolic changes) and echocardiographic parameters (ductus arteriosus diameter, ductus arteriosus/weight ratio, left atrium/ aorta ratio, left ventricular diastolic diameter, and transductal flow direction, pattern and velocity) were analyzed. The clinical and echocardiographic parameters analyzed were considered statistically significant when ppatent ductus arteriosus was 61.3%; 56 received treatment (46 pharmacological and 10 surgical treatment), 11 had spontaneous closure, 4 died, and 2 were discharged with patent ductus arteriosus. A higher incidence of chorioamnionitis, use of surfactant, lower weight and gestational age, sepsis, heart murmur, ventilatory support and worse oxygenation indices were observed in the neonates receiving treatment. The group with spontaneous closure had a smaller ductus arteriosus diameter, lower ductus arteriosus/weight ratio, and higher transductal flow velocity. Based on clinical and echocardiographic parameters, the neonates with spontaneous closure of the ductus arteriosus could be differentiated from those who required treatment.

  20. ECHOCARDIOGRAPHIC FINDINGS OF BIDIMENSIONAL MODE, M-MODE, AND DOPPLER OF CLINICALLY NORMAL BLACK-RUMPED AGOUTI (DASYPROCTA PRYMNOLOPHA, WAGLER 1831).

    Science.gov (United States)

    Diniz, Anaemilia das Neves; Pessoa, Gerson Tavares; da Silva Moura, Laecio; de Sousa, André Braga; Sousa, Francisco das Chagas Araújo; de Sá Rodrigues, Renan Paraguassu; da Silva Barbosa, Maria Angélica Parente; de Almeida, Hatawa Melo; Freire, Larisse Danielle Silva; Sanches, Marina Pinto; Júnior, Antônio Augusto Nascimento Machado; Guerra, Porfírio Candanedo; Neves, Willams Costa; de Sousa, João Macedo; Bolfer, Luiz; Giglio, Robson Fortes; Alves, Flávio Ribeiro

    2017-06-01

    The black-rumped agouti ( Dasyprocta prymnolopha , Wagler 1831) is currently under intense ecologic pressure, which has resulted in its disappearance from some regions of Brazil. Echocardiography is widely used in veterinary medicine but it is not yet part of the clinical routine for wild animals. The objective of the present study was to assess the applicability of the echocardiographic exam in nonanesthetized agouti and to establish normal reference values for echocardiographic measurements in bidimensional mode (2D), M-mode, and Doppler for this species, and a lead II electrocardiogram was simultaneously recorded. Twenty agouti were used in this study. All the echocardiographic measurements were positively correlated with weight (P 0.05). Blood flow velocities in the pulmonary and aortic artery ranged from 67.32-71.28 cm/sec and 79.22-101.84 cm/sec, respectively. The isovolumic relaxation time was assessed in all the animals and ranged from 38.5 to 56.6 ms. The maximum value for the nonfused E and A waves and the Et and At waves was 158 beats/min for both. The results obtained for the morphologic and heart hemodynamic measurements can guide future studies and help in the clinical management of these animals in captivity.

  1. A prospective echocardiographic evaluation of pulmonary hypertension in chronic hemodialysis patients in the United States: prevalence and clinical significance

    Directory of Open Access Journals (Sweden)

    Kumudha Ramasubbu

    2010-09-01

    Full Text Available Kumudha Ramasubbu1, Anita Deswal1, Cheryl Herdejurgen2, David Aguilar1, Adaani E Frost21Section of Cardiology, Michael E DeBakey VA Medical Center and Baylor College of Medicine, Houston, Texas, USA; 2Section of Pulmonary and Critical Care Medicine, Baylor College of Medicine, Houston, Texas, USABackground: Pulmonary hypertension (PH, a disease which carries substantial morbidity and mortality, has been reported to occur in 25%–45% of dialysis patients. No prospective evaluation of the prevalence or clinical significance of PH in chronic dialysis patients in the United States (US has been undertaken.Methods: Echocardiograms were performed prospectively in chronic hemodialysis patients prior to dialysis at a single dialysis center. PH was defined as a tricuspid regurgitant jet ≥2.5 m/s and “more severe PH” as ≥3.0 m/s. Clinical outcomes recovered were all-cause hospitalizations and death at 12 months.Results: In a cohort of 90 patients, 42 patients (47% met the definition of PH. Of those, 18 patients (20% met the definition of more severe PH. At 12 months, mortality was significantly higher in patients with PH (26% compared with patients without PH (6%. All-cause hospitalizations were similar in patients with PH and without PH. Echocardiographic findings suggesting impaired left ventricular function and elevated pulmonary capillary wedge pressure were significantly associated with PH.Conclusion: This prospective cross-sectional study of a single dialysis unit suggests that PH may be present in nearly half of US dialysis patients and when present is associated with increased mortality. Echocardiographic findings demonstrate an association between elevated filling pressures, elevated pulmonary artery pressures, and higher mortality, suggesting that the PH may be secondary to diastolic dysfunction and compounded by volume overload.Keywords: renal failure, pulmonary hypertension, diastolic dysfunction

  2. Echocardiographic Evaluation of Tricuspid Prosthetic Valves: An Update

    Directory of Open Access Journals (Sweden)

    Dimitrios Maragiannis, MD, FASE, FACC

    2016-05-01

    Full Text Available This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.

  3. Echocardiographic evaluation of simple versus complex congenital heart disease in a tertiary care Paediatrics Hospital

    OpenAIRE

    Uttam Kumar Sarkar; Anish Chatterjee; Suprit Basu; Atanu Pan; Sumit Periwal

    2017-01-01

    Background & Objectives:Congenital heart diseases are treatable either by catheter based intervention or open heart surgery according to their quality. In our study we aim to analyze congenital heart disease echocardiographically into simple versus complex heart disease at a tertiary care centre with a public health planning and policy making perspective.Materials & Methods:This hospital based study was done on 1010 patients, both from in-patient and out-patient, who were clinically s...

  4. ECHOCARDIOGRAPHIC DIAGNOSTICS OF CARCINOID HEART DISEASE

    Directory of Open Access Journals (Sweden)

    Janez Ravnik

    2002-09-01

    Full Text Available Background. Carcinoid heart disease is a rare heart disease which affects endocard and heart valves on the right side of heart. It affects only patients with manifested carcinoid syndrome, which is thought to be the consequence of secretory active metastases of carcinoid tumour. The carcinoid endocardial plaques cause structural changes of tricuspid and pulmonic valve and later on their stenosis and/or insufficiency.Patients and methods. In this article we introduce a carcinoid valve heart disease (CVHD scoring system for easier end exact echocardiographic diagnostics. Four echocardiographic parameters are beeing estimated: structural changes of tricuspid valve, tricuspid valve regurgitation, stenosis of pulmonic valve and pulmonic valve regurgitation.Conclusions. The scoring system allows us to make an early diagnosis and evaluation of progression of carcinoid heart disease, which is very important for planning the treatment process. Our experiences confirm the usefulness of this scoring system in echocardiographic follow–up of patients with carcinoid syndrome.

  5. Initial Surgical Experience with Aortic Valve Repair: Clinical and Echocardiographic Results

    Directory of Open Access Journals (Sweden)

    Francisco Diniz Affonso da Costa

    Full Text Available Abstract Introduction: Due to late complications associated with the use of conventional prosthetic heart valves, several centers have advocated aortic valve repair and/or valve sparing aortic root replacement for patients with aortic valve insufficiency, in order to enhance late survival and minimize adverse postoperative events. Methods: From March/2012 thru March 2015, 37 patients consecutively underwent conservative operations of the aortic valve and/or aortic root. Mean age was 48±16 years and 81% were males. The aortic valve was bicuspid in 54% and tricuspid in the remaining. All were operated with the aid of intraoperative transesophageal echocardiography. Surgical techniques consisted of replacing the aortic root with a Dacron graft whenever it was dilated or aneurysmatic, using either the remodeling or the reimplantation technique, besides correcting leaflet prolapse when present. Patients were sequentially evaluated with clinical and echocardiographic studies and mean follow-up time was 16±5 months. Results: Thirty-day mortality was 2.7%. In addition there were two late deaths, with late survival being 85% (CI 95% - 68%-95% at two years. Two patients were reoperated due to primary structural valve failure. Freedom from reoperation or from primary structural valve failure was 90% (CI 95% - 66%-97% and 91% (CI 95% - 69%-97% at 2 years, respectively. During clinical follow-up up to 3 years, there were no cases of thromboembolism, hemorrhage or endocarditis. Conclusions: Although this represents an initial series, these data demonstrates that aortic valve repair and/or valve sparing aortic root surgery can be performed with satisfactory immediate and short-term results.

  6. Echocardiographic findings in haemodialysis patients according to their state of hydration.

    Science.gov (United States)

    Cristina Di Gioia, María; Gascuena, Raul; Gallar, Paloma; Cobo, Gabriela; Camacho, Rosa; Acosta, Nuria; Baranyi, Zsofia; Rodriguez, Isabel; Oliet, Aniana; Ortega, Olimpia; Fernandez, Inmaculada; Mon, Carmen; Ortiz, Milagros; Manzano, Mari C; Herrero, Juan C; Martinez, José I; Palma, Joaquín; Vigil, Ana

    Chronic fluid overload is frequent in hemodialysis patients (P) and it associates with hypertension, left ventricular hypertrophy (LVH) and higher mortality. Moreover, echocardiographic data assessing fluid overload is limited. Our aim was to evaluate the relationship between fluid overload measured by bioimpedance spectroscopy (BIS) and different echocardiographic parameters. Cross-sectional observational study including 76 stable patients. Dry weight was clinically assessed. BIS and echocardiography were performed. Weekly time-averaged fluid overload (TAFO) and relative fluid overload (FO/ECW) were calculated using BIS measurements. Based on TAFO three groups were defined: A- dehydrated, TAFO 1.5 l: 18 (24%). We found significant correlation between TAFO and left atrial volume index (LAVI) (r: 0.29; p=0.013) but not with FO/ECW (r 0.06; p=0.61). TAFO, but not FO/ECW kept a significant relationship with LAVI (p=0.03) using One-Way ANOVA test and linear regression methods. LVH was present in 73.7% (concentric 63.2%, eccentric in 10.5%). No differences between groups in the presence of LVH or left ventricular mass index were found. We found that left atrial volume index determined by echocardiographic Area-length method, but not left ventricle hypertrophy or dimensions of cavities, are related on hydration status based on bioimpedance measured time-averaged fluid overload (TAFO), and not with FO/ECW. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  7. Mitral valve repair: an echocardiographic review: Part 2.

    Science.gov (United States)

    Maslow, Andrew

    2015-04-01

    Echocardiographic imaging of the mitral valve before and immediately after repair is crucial to the immediate and long-term outcome. Prior to mitral valve repair, echocardiographic imaging helps determine the feasibility and method of repair. After the repair, echocardiographic imaging displays the new baseline anatomy, assesses function, and determines whether or not further management is necessary. Three-dimensional imaging has improved the assessment of the mitral valve and facilitates communication with the surgeon by providing the surgeon with an image that he/she might see upon opening up the atrium. Further advancements in imaging will continue to improve the understanding of the function and dysfunction of the mitral valve both before and after repair. This information will improve treatment options, timing of invasive therapies, and advancements of repair techniques to yield better short- and long-term patient outcomes. The purpose of this review was to connect the echocardiographic evaluation with the surgical procedure. Bridging the pre- and post-CPB imaging with the surgical procedure allows a greater understanding of mitral valve repair.

  8. Utilization of a pressure sensor guidewire to measure bileaflet mechanical valve gradients: hemodynamic and echocardiographic sequelae.

    Science.gov (United States)

    Doorey, Andrew J; Gakhal, Mandip; Pasquale, Michael J

    2006-04-01

    Suspected prosthetic valve dysfunction is a difficult clinical problem, because of the high risk of repeat valvular surgery. Echocardiographic measurements of prosthetic valvular dysfunction can be misleading, especially with bileaflet valves. Direct measurement of trans-valvular gradients is problematic because of potentially serious catheter entrapment issues. We report a case in which a high-fidelity pressure sensor angioplasty guidewire was used to cross prosthetic mitral and aortic valves in a patient, with hemodynamic and echocardiographic assessment. This technique was safe and effective, refuting the inaccurate non-invasive tests that over-estimated the aortic valvular gradient.

  9. Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

    Science.gov (United States)

    Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio

    2013-08-01

    Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (pimplants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.

  10. Contour extraction of echocardiographic images based on pre-processing

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana [Department of Multimedia, Faculty of Computer Science and Information Technology, Department of Computer and Communication Systems Engineering, Faculty of Engineering University Putra Malaysia 43400 Serdang, Selangor (Malaysia); Zamrin, D M [Department of Surgery, Faculty of Medicine, National University of Malaysia, 56000 Cheras, Kuala Lumpur (Malaysia); Saripan, M Iqbal

    2011-02-15

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  11. Contour extraction of echocardiographic images based on pre-processing

    International Nuclear Information System (INIS)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana; Zamrin, D M; Saripan, M Iqbal

    2011-01-01

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  12. Echocardiographic evaluation of pre-diagnostic development in young relatives genetically predisposed to hypertrophic cardiomyopathy

    DEFF Research Database (Denmark)

    Jensen, Morten K; Havndrup, Ole; Christiansen, Michael

    2015-01-01

    Identification of the first echocardiographic manifestations of hypertrophic cardiomyopathy may be important for clinical management and our understanding of the pathogenesis. We studied the development of pre-diagnostic echocardiographic changes in young relatives to HCM patients during long...... of relatives with unknown genetic status. Children carrying pathogenic sarcomere gene mutations develop reduced LVEDd and increased E/e' as first pre-diagnostic echocardiographic manifestations during follow-up into adulthood.......-term years follow-up. HCM-relatives not fulfilling the diagnostic criteria for HCM and age of family screening of 11 sarcomere genes, CRYAB, α-GAL, and titin, we evaluated...

  13. Predictors of Total Mortality and Echocardiographic Response for Cardiac Resynchronization Therapy: A Cohort Study

    Directory of Open Access Journals (Sweden)

    Guilherme Ferreira Gazzoni

    2017-11-01

    Full Text Available Abstract Background: Clinical studies demonstrate that up to 40% of patients do not respond to cardiac resynchronization therapy (CRT, thus, appropriate patient selection is critical to the success of CRT in heart failure. Objective: Evaluation of mortality predictors and response to CRT in the Brazilian scenario. Methods: Retrospective cohort study including patients submitted to CRT in a tertiary hospital in southern Brazil from 2008 to 2014. Survival was assessed through a database of the State Department of Health (RS. Predictors of echocardiographic response were evaluated using Poisson regression. Survival analysis was performed by Cox regression and Kaplan Meyer curves. A two-tailed p value less than 0.05 was considered statistically significant. Results: A total of 170 patients with an average follow-up of 1011 ± 632 days were included. The total mortality was 30%. The independent predictors of mortality were age (hazard ratio [HR] of 1.05, p = 0.027, previous acute myocardial infarction (AMI (HR of 2.17, p = 0.049 and chronic obstructive pulmonary disease (COPD (HR of 3.13, p = 0.015. The percentage of biventricular stimulation at 6 months was identified as protective factor of mortality ([HR] 0.97, p = 0.048. The independent predictors associated with the echocardiographic response were absence of mitral insufficiency, presence of left bundle branch block and percentage of biventricular stimulation. Conclusion: Mortality in patients submitted to CRT in a tertiary hospital was independently associated with age, presence of COPD and previous AMI. The percentage of biventricular pacing evaluated 6 months after resynchronizer implantation was independently associated with improved survival and echocardiographic response.

  14. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  15. Echocardiographic evaluation of simple versus complex congenital heart disease in a tertiary care Paediatrics Hospital

    Directory of Open Access Journals (Sweden)

    Uttam Kumar Sarkar

    2017-10-01

    Full Text Available Background & Objectives:Congenital heart diseases are treatable either by catheter based intervention or open heart surgery according to their quality. In our study we aim to analyze congenital heart disease echocardiographically into simple versus complex heart disease at a tertiary care centre with a public health planning and policy making perspective.Materials & Methods:This hospital based study was done on 1010 patients, both from in-patient and out-patient, who were clinically suspected to have heart disease from January 2015 to September 2016 at Dr.B.C.Roy P.G.I.P.S. Kolkata and echocardiographically categorized.Results:A VSD was the commonest acyanotic heart disease (17. 08%.Tetralogy of Fallot (TOF was commonest complex cyanotic heart disease (10.64%, VSD +ASD was the commonest combined lesion (8.12%. Simple heart lesions (63.1% were commoner than complex (36.9% congenital heart diseases.Conclusion:Health policy makers should give due care to manage Congenital Heart Disease either catheter based or surgically keeping in mind about 63.1% of the lesions are simple cardiac lesions and 36.9% lesions are complex cardiac lesion where complex surgery is required. 

  16. Effect of gender on echocardiographic outcomes of patients presenting with mitral stenosis at a tertiary care hospital

    International Nuclear Information System (INIS)

    Saeed, M.; Haq, I.U.

    2011-01-01

    To assess the gender-based differences in the echocardiographic outcomes of patients with mitral stenosis presenting at a tertiary care hospital and the clinical implications of such differences. Methods: A total of 90 echocardiographs of both men and women (aged=15 years) having mitral valve area (MVA) less than 4 cm/sup 2/ were assessed. In addition to MVA, pressure half time and left atrial diameter (LAD) of the patients was also recorded. Other co-existing valvular lesions were also assessed in addition to mitral stenosis. Statistical analysis was done using SPSS-17. Results: A higher prevalence of mitral stenosis (MS) was found in women than men (76.66% vs 24.44%). Men were having more severe mitral stenosis as compared to women (MVA=1.19 cm/sup 2/ vs 1.32 cm/sup 2/). This also resulted in significantly higher left atrial dilatation in males as compared to women (45.09 vs 41.75, p=0.0422). Most of the patients had other coexisting valvular lesions and isolated MS was rare. However, men had a predominance of aortic stenosis along with mitral stenosis (27% vs 4%, p=0.0059) whereas women had a higher prevalence of mitral regurgitation along with mitral stenosis than the men (65% vs 36%, p=0.0258). Conclusion: There were certain significant differences in echocardiographic outcomes of patients based upon their gender. A gender-specific management approach towards the patients with mitral stenosis is essential to have better outcome. (author)

  17. Clinical and Echocardiographic Evaluation of Regional Systolic Function Detected by Tissue Doppler Imaging in Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    A Sadeghpour

    2009-09-01

    Full Text Available Background: Hypertrophic cardiomyopathy (HCM is the most common type of the genetic cardiovasculardiseases. Regarding to tremendous heterogeneity in the phenotypic expression of HCM, which is generally unrelatedto genotype, we aimed to study, clinical and echocardiographic parameters such as Tissue Doppler Imaging(TDI in various subtypes of HCM patients and evaluate the influence of race and gender in Iranian patients.Methods: Patients with HCM underwent a complete clinical and echocardiographic study including TDI toassess regional systolic contraction( in the 12 segments and early diastolic annular velocity (Em from theseptal mitral annulus.Results: The study comprised 41 patients (20 women, mean age = 41 ± 15 years with mean LVEF 55%±4.8%and mean maximal septal thickness 2.07cm. Considering LVOT gradient>30mmHg, hypertrophic obstructivecardiomyopathy (HOCM was found in 18 (45%. Asymmetric septal hypertrophy (ASH existed in 27 patients(67%, systolic anterior motion of anterior mitral leaflet (SAM in 25 persons (64%. Nineteen patients (46.3%were included in NYHA function class (FC II and 6 (14.7% in FC III or higher. We found syncope in 10(24.4%, chest pain in 4 (9.8%, atrial fibrilation in 14.6 % and ventricular arrhythmias in (17.1% of patients.History of ICD was seen in 7 (17.1% and PPM in 9 cases. Mean E’ velocity was 5.44± 1.65 cm/sec and S velocity5.70± 1.49 cm/sec with significant lower S velocity and E’ in syncope patients. Overall, HOCM patients hadgrade II diastolic dysfunction with E/É >15(17.54±7.46. Majority (25 of cases (61% were categorized in typeIII of HCM. RV involvement was observed in 11 patients (28.2%.No significant differences existed betweenprevalence of syncope and dysrhythmia among HCM and HOCM patients.Conclusion: In our study, we found lower detection of latent HOCM, compared to other studies, suggestive ofinadequate use of appropriate provocative maneuvers such as exercise stress echocardiography and amyl

  18. Which Criteria are More Valuable in Defining Hemodynamic Significance of Patent Ductus Arteriosus in Premature Infants? Respiratory or Echocardiographic?

    Directory of Open Access Journals (Sweden)

    İrfan Oğuz Şahin

    2017-03-01

    Full Text Available Aim: Patent ductus arteriosus (PDA is a frequent health problem in premature infants. Pharmacologic closure is recommended only for hemodynamically significant PDA (hsPDA that is defined according to the clinical and echocardiographic criteria. The aim of this study was to explore the value of commonly used criteria in defining hsPDA and predicting the required number of courses of ibuprofen treatment to close PDA in premature infants. Methods: Sixty premature infants with a gestational age of ≤33 weeks were evaluated prospectively. Clinical and echocardiographic criteria [O2 requirement, ductus diameter (DD and left atrial-to-aortic root diameter ratio (LA:Ao] were used to define hsPDA. Clinical improvement after pharmacologic closure of PDA and association between the criteria and required number of ibuprofen courses were investigated. Results: O2 requirement decreased by PDA closure but was not different between patients with hsPDA and the others with PDA. Also, O2 requirement was not found to be associated with required number of ibuprofen courses. DD and LA:Ao were greater in patients with hsPDA. DD was found to be associated with required number of courses of ibuprofen treatment. Conclusion: Although there was an improvement in O2 requirement with PDA closure, echocardiographic criteria were found to be more valuable in defining hsPDA. DD should also be used to estimate the duration of treatment.

  19. Graph cut-based method for segmenting the left ventricle from MRI or echocardiographic images.

    Science.gov (United States)

    Bernier, Michael; Jodoin, Pierre-Marc; Humbert, Olivier; Lalande, Alain

    2017-06-01

    In this paper, we present a fast and interactive graph cut method for 3D segmentation of the endocardial wall of the left ventricle (LV) adapted to work on two of the most widely used modalities: magnetic resonance imaging (MRI) and echocardiography. Our method accounts for the fundamentally different nature of both modalities: 3D echocardiographic images have a low contrast, a poor signal-to-noise ratio and frequent signal drop, while MR images are more detailed but also cluttered and contain highly anisotropic voxels. The main characteristic of our method is to work in a 3D Bezier coordinate system instead of the original Euclidean space. This comes with several advantages, including an implicit shape prior and a result guarantied not to have any holes in it. The proposed method is made of 4 steps. First, a 3D sampling of the LV cavity is made based on a Bezier coordinate system. This allows to warp the input 3D image to a Bezier space in which a plane corresponds to an anatomically plausible 3D Euclidean bullet shape. Second, a 3D graph is built and an energy term (which is based on the image gradient and a 3D probability map) is assigned to each edge of the graph, some of which being given an infinite energy to ensure the resulting 3D structure passes through key anatomical points. Third, a max-flow min-cut procedure is executed on the energy graph to delineate the endocardial surface. And fourth, the resulting surface is projected back to the Euclidean space where a post-processing convex hull algorithm is applied on every short axis slice to remove local concavities. Results obtained on two datasets reveal that our method takes between 2 and 5s to segment a 3D volume, it has better results overall than most state-of-the-art methods on the CETUS echocardiographic dataset and is statistically as good as a human operator on MR images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Echocardiographic screening for subclinical rheumatic heart disease remains a research tool pending studies of impact on prognosis.

    Science.gov (United States)

    Zühlke, Liesl; Mayosi, Bongani M

    2013-03-01

    The application of portable echocardiography to the screening of asymptomatic children and young adults for rheumatic heart disease (RHD) in developing countries indicates that the disease may affect 62 million to 78 million individuals worldwide, which could potentially result in 1.4 million deaths per year from RHD and its complications. The World Heart Federation has developed a guideline for the echocardiographic diagnosis of RHD in asymptomatic individuals without a history of acute rheumatic fever (ARF) in order to ensure the reliability, comparability, and reproducibility of findings of the echocardiographic screening studies. Early studies suggest that a third of individuals with asymptomatic subclinical RHD revert to normal echocardiographic findings on repeat testing after 6-12 months, suggesting that repeat echocardiography may be necessary to confirm the findings prior to consideration of interventions such as antibiotic prophylaxis. It is not known, however, whether echocardiographic screening for asymptomatic subclinical RHD or the introduction of antibiotic prophylaxis for affected individuals improves the prognosis of RHD. Furthermore, the cost-effectiveness of this screening method has not been established in the vast majority of affected countries. Therefore, echocardiographic screening for asymptomatic subclinical RHD remains a research tool until studies of impact on prognosis and cost-effectiveness are conducted.

  1. Can echocardiographic findings predict falls in older persons?

    NARCIS (Netherlands)

    N. van der Velde (Nathalie); B.H.Ch. Stricker (Bruno); J.R.T.C. Roelandt (Jos); F.J. ten Cate (Folkert); T.J.M. van der Cammen (Tischa)

    2007-01-01

    textabstractBackground. The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. Method and

  2. Influence of Angiotensin-Converting-Enzyme Gene Polymorphism on Echocardiographic Data of Patients with Ischemic Heart Failure

    Science.gov (United States)

    Duque, Gustavo Salgado; da Silva, Dayse Aparecida; de Albuquerque, Felipe Neves; Schneider, Roberta Siuffo; Gimenez, Alinne; Pozzan, Roberto; Rocha, Ricardo Mourilhe; de Albuquerque, Denilson Campos

    2016-01-01

    Background Association between angiotensin-converting-enzyme (ACE) gene polymorphisms and different clinical and echocardiographic outcomes has been described in patients with heart failure (HF) and coronary artery disease. Studying the genetic profile of the local population with both diseases is necessary to assess the occurrence of that association. Objectives To assess the frequency of ACE gene polymorphisms in patients with ischemic HF in a Rio de Janeiro population, as well as its association with echocardiographic findings. Methods Genetic assessment of I/D ACE polymorphism in association with clinical, laboratory and echocardiographic analysis of 99 patients. Results The allele frequency was: 53 I alleles, and 145 D alleles. Genotype frequencies were: 49.5% DD; 47.48% DI; 3.02% II. Drug treatment was optimized: 98% on beta-blockers, and 84.8% on ACE inhibitors or angiotensin-receptor blocker. Echocardiographic findings: difference between left ventricular diastolic diameters (ΔLVDD) during follow-up: 2.98±8.94 (DD) vs. 0.68±8.12 (DI) vs. -11.0±7.00 (II), p=0.018; worsening during follow-up of the LV systolic diameter (LVSD): 65.3% DD vs. 19.0% DI vs. 0.0% II, p=0.01; of the LV diastolic diameter (LVDD): 65.3% DD vs. 46.8% DI vs. 0.0% II, p=0.03; and of the LV ejection fraction (LVEF): 67.3% DD vs. 40.4% DI vs. 33.3% II, p=0.024. Correlated with D allele: ΔLVEF, ΔLVSD, ΔLVDD. Conclusions More DD genotype patients had worsening of the LVEF, LVSD and LVDD, followed by DI genotype patients, while II genotype patients had the best outcome. The same pattern was observed for ΔLVDD. PMID:27812677

  3. Can echocardiographic findings predict falls in older persons?

    NARCIS (Netherlands)

    van der Velde, Nathalie; Stricker, Bruno H. Ch; Roelandt, Jos R. T. C.; ten Cate, Folkert J.; van der Cammen, Tischa J. M.

    2007-01-01

    BACKGROUND: The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. METHOD AND FINDINGS: In

  4. [Serial clinical and echocardiographic evaluation in children with Marfan syndrome].

    Science.gov (United States)

    Lopez, Victor Manuel Oporto; Perez, Ana Beatriz Alvarez; Moisés, Valdir Ambrósio; Gomes, Lourdes; Pedreira, Patricia da Silveira; Silva, Célia C; Campos Filho, Orlando; Carvalho, Antônio Carlos C

    2005-11-01

    To describe the clinical cardiac manifestations and temporal evolution of Marfan syndrome in children; to estimate the incidence of annuloaortic ectasia and mitral valve prolapse; and to evaluate tolerability and efficacy of beta-blockers in these patients. During one year, 21 children with Marfan syndrome underwent serial clinical and echocardiographic examinations. Echocardiograms assessed: the presence of mitral valve prolapse, aortic root diameter, mitral and aortic valves regurgitation, and aortic enlargement during beta-blocker therapy. Eleven patients had two measurements of the aortic root taken one year apart. The children were asymptomatic throughout the study. Mitral prolapse was found in 11 (52%) children. Annuloaortic ectasia occurred in 16 (76%) patients and found to be mild in 42.8%, moderate in 9.5%, and severe in 23.8%. One of these patients underwent aortic valve replacement and repair of the ascending aorta by the Bentall-De Bono technique, with good results. Heart rate decreased by 13.6% (from 85 to 73 bpm; p < 0.009) with the use of beta-blockers; however, aortic root diameter increased by 1.4 mm/year (p < 0.02). One child could not be given beta-blockers due to bronchial asthma, and no significant side effects were observed in the remaining children, including one who also had bronchial asthma. The children remained asymptomatic throughout the study, the use of beta-blockers led to a significant decrease in heart rate, and no significant adverse effects were observed. Contrary to the literature, incidence of annuloaortic ectasia was high among the study population, greater than that of mitral valve prolapse, even during beta-blocker therapy.

  5. Childhood acquired heart disease in Nigeria: an echocardiographic ...

    African Journals Online (AJOL)

    Introduction: Acquired heart diseases (AHD) are not uncommon in children. The current multi-center study aims to provide a more representative data of AHD in Nigeria. Methods: Over 42 months, children referred for echocardiographic evaluation who had confirmed AHD in three centers in Nigeria were recruited. The data ...

  6. Echocardiographic agreement in the diagnostic evaluation for infective endocarditis

    DEFF Research Database (Denmark)

    Lauridsen, Trine Kiilerich; Selton-Suty, Christine; Tong, Steven Y C

    2016-01-01

    Echocardiography is essential for the diagnosis and management of infective endocarditis (IE). However, the reproducibility for the echocardiographic assessment of variables relevant to IE is unknown. Objectives of this study were: (1) To define the reproducibility for IE echocardiographic...... variables and (2) to describe a methodology for assessing quality in an observational cohort containing site-interpreted data. IE reproducibility was assessed on a subset of echocardiograms from subjects enrolled in the International Collaboration on Endocarditis registry. Specific echocardiographic case...

  7. A comparison between brachial and echocardiographic systolic time intervals.

    Directory of Open Access Journals (Sweden)

    Ho-Ming Su

    Full Text Available Systolic time interval (STI is an established noninvasive technique for the assessment of cardiac function. Brachial STIs can be automatically determined by an ankle-brachial index (ABI-form device. The aims of this study are to evaluate whether the STIs measured from ABI-form device can represent those measured from echocardiography and to compare the diagnostic values of brachial and echocardiographic STIs in the prediction of left ventricular ejection fraction (LVEF <50%. A total of 849 patients were included in the study. Brachial pre-ejection period (bPEP and brachial ejection time (bET were measured using an ABI-form device and pre-ejection period (PEP and ejection time (ET were measured from echocardiography. Agreement was assessed by correlation coefficient and Bland-Altman plot. Brachial STIs had a significant correlation with echocardiographic STIs (r = 0.644, P<0.001 for bPEP and PEP; r  = 0.850, P<0.001 for bET and ET; r = 0.708, P<0.001 for bPEP/bET and PEP/ET. The disagreement between brachial and echocardiographic STIs (brachial STIs minus echocardiographic STIs was 28.55 ms for bPEP and PEP, -4.15 ms for bET and ET and -0.11 for bPEP/bET and PEP/ET. The areas under the curve for bPEP/bET and PEP/ET in the prediction of LVEF <50% were 0.771 and 0.765, respectively. Brachial STIs were good alternatives to STIs obtained from echocardiography and also helpful in prediction of LVEF <50%. Brachial STIs automatically obtained from an ABI-form device may be helpful for evaluation of left ventricular systolic dysfunction.

  8. The effects of detomidine, romifidine or acepromazine on echocardiographic measurements and cardiac function in normal horses.

    Science.gov (United States)

    Buhl, Rikke; Ersbøll, Annette K; Larsen, Nanna H; Eriksen, Lis; Koch, Jørgen

    2007-01-01

    To evaluate by echo- and electrocardiography the cardiac effects of sedation with detomidine hydrochloride, romifidine hydrochloride or acepromazine maleate in horses. An experimental study using a cross-over design without randomization. Eight clinically normal Standardbred trotters. Echocardiographic examinations (two-dimensional, guided M-mode and colour Doppler) were recorded on five different days. Heart rate (HR) and standard limb lead electrocardiograms were also obtained. Subsequently, horses were sedated with detomidine (0.01 mg kg(-1)), romifidine (0.04 mg kg(-1)) or acepromazine (0.1 mg kg(-1)) administered intravenously and all examinations repeated. Heart rate before treatment with the three drugs did not differ significantly (p = 0.98). Both detomidine and romifidine induced a significant decrease (p detomidine, there was a significant increase in LVIDd (left ventricular internal diameter in diastole; p = 0.034) and LVIDs (left ventricular internal diameter in systole; p detomidine and to a lesser extent romifidine at the doses given in this study has a significant effect on heart function, echocardiographic measurements of heart dimensions and the occurrence of valvular regurgitation. Although the clinical significance of these results may be minimal, the potential effects of sedative drugs should be taken into account when echocardiographic variables are interpreted in clinical cases.

  9. Eleven fetal echocardiographic planes using 4-dimensional ultrasound with spatio-temporal image correlation (STIC): a logical approach to fetal heart volume analysis.

    Science.gov (United States)

    Jantarasaengaram, Surasak; Vairojanavong, Kittipong

    2010-09-15

    Theoretically, a cross-sectional image of any cardiac planes can be obtained from a STIC fetal heart volume dataset. We described a method to display 11 fetal echocardiographic planes from STIC volumes. Fetal heart volume datasets were acquired by transverse acquisition from 200 normal fetuses at 15 to 40 weeks of gestation. Analysis of the volume datasets using the described technique to display 11 echocardiographic planes in the multiplanar display mode were performed offline. Volume datasets from 18 fetuses were excluded due to poor image resolution. The mean visualization rates for all echocardiographic planes at 15-17, 18-22, 23-27, 28-32 and 33-40 weeks of gestation fetuses were 85.6% (range 45.2-96.8%, N = 31), 92.9% (range 64.0-100%, N = 64), 93.4% (range 51.4-100%, N = 37), 88.7%(range 54.5-100%, N = 33) and 81.8% (range 23.5-100%, N = 17) respectively. Overall, the applied technique can favorably display the pertinent echocardiographic planes. Description of the presented method provides a logical approach to explore the fetal heart volumes.

  10. Echocardiographic abnormalities in hypertensive patients

    International Nuclear Information System (INIS)

    Rodulfo Garcia, Maikel; Tornes Perez, Victor Manuel; Castellanos Tardo, Juan Ramon

    2012-01-01

    A descriptive cross-sectional study was carried out in 120 hypertensive patients with a course of 5 or more years, who went to the emergency room of 'Saturnino Lora' Provincial Teaching Hospital from November 2010 to November 2011 in order to determine the presence or absence of echocardiographic abnormalities typical of hypertension. Of these, 78,3 % was affected, most of whom reported not to continue with regular previous medical treatment, and 21,7 % had not these abnormalities. Age group of 50-60 years, males and blacks prevailed in the case material. The most significant echocardiographic findings were left ventricular hypertrophy and heart failure with ejection fraction of left ventricle preserved

  11. Echocardiographic study of left atrial myxoma

    Directory of Open Access Journals (Sweden)

    Dalal J

    1979-01-01

    Full Text Available Four cases of left atrial myxoma were diagnosed pre-operatively by echocardiography. All cases showed characteristic echocardio-graphic features of variegated shadows behind the mitral valve in diastole and within the left atrium in systole. In two cases the my-xomas were surgically removed and confirmed on histology. In one case the post-operative echocardiogram showed complete dis-appearance of the abnormal shadows. Echocardiography is the most reliable method today for the diagnosis of a myxoma.

  12. A rapid echocardiographic screening protocol for rheumatic heart disease in Samoa: a high prevalence of advanced disease.

    Science.gov (United States)

    Allen, Marvin; Allen, John; Naseri, Take; Gardner, Rebecca; Tolley, Dennis; Allen, Lori

    2017-10-01

    Echocardiography has been proposed as a method to screen children for rheumatic heart disease. The World Heart Federation has established guidelines for echocardiographic screening. In this study, we describe a rapid echocardiogram screening protocol according to the World Heart Federation guidelines in Samoa, endemic for rheumatic heart disease. We performed echocardiogram screening in schoolchildren in Samoa between 2013 and 2015. A brief screening echocardiogram was performed on all students. Children with predefined criteria suspicious for rheumatic hear diseases were referred for a more comprehensive echocardiogram. Complete echocardiograms were classified according to the World Heart Federation guidelines and severity of valve disease. Echocardiographic screening was performed on 11,434 children, with a mean age of 10.2 years; 51% of them were females. A total of 558 (4.8%) children underwent comprehensive echocardiography, including 49 students who were randomly selected as controls. Definite rheumatic heart disease was observed in 115 students (10.0 per 1000): 92 students were classified as borderline (8.0 per 1000) and 23 with CHD. Advanced disease was identified in 50 students (4.4 per 1000): 15 with severe mitral regurgitation, five with severe aortic regurgitation, 11 with mitral stenoses, and 19 with mitral and aortic valve disease. We successfully applied a rapid echocardiographic screening protocol to a large number of students over a short time period - 28 days of screening over a 3-year time period - to identify a high prevalence of rheumatic heart disease. We also reported a significantly higher rate of advanced disease compared with previously published echocardiographic screening programmes.

  13. Reversal of echocardiographic right-sided heart pathology in a dog with severe pulmonary hypertension: a case report

    Directory of Open Access Journals (Sweden)

    McMahon P

    2015-06-01

    Full Text Available Peggy McMahon,1 Carley Saelinger 2  1Emergency and Critical Care Department, 2Cardiology Department, Animal Specialty and Emergency Center, Los Angeles, CA, USA Abstract: Pathologic right-sided heart changes are a common echocardiographic finding in patients with pulmonary hypertension (PH. Canines with PH may have right heart pathology documented via echocardiographic color Doppler interrogation including tricuspid valve regurgitation, pulmonic valve insufficiency, elevated pulmonary arterial systolic pressure, elevated pulmonary arterial diastolic pressure, and alterations in ejection profiles. Two-dimensional echocardiographic findings may include right ventricular hypertrophy, interventricular septal flattening, paradoxical interventricular septal motion, pulmonary artery dilation, and potentially abnormal left heart dimensions. In veterinary medicine, much confidence is given to the measurement of pulmonary arterial systolic pressure estimated from tricuspid valve regurgitation to grade the severity of PH and monitor its improvement with little emphasis placed on the integration of two-dimensional echocardiographic right and left heart pathology in conjunction with Doppler findings. To the authors’ knowledge, marked improvement and/or resolution of echocardiographic-documented right heart pathology have not been previously reported in the veterinary literature. This case report documents profound echocardiographic improvement of right-sided heart disease in a dog with severe PH. Keywords: canine, pulmonary hypertension, tricuspid valve regurgitation, right heart hypertrophy, sildenafil  

  14. The septal bulge--an early echocardiographic sign in hypertensive heart disease.

    Science.gov (United States)

    Gaudron, Philipp Daniel; Liu, Dan; Scholz, Friederike; Hu, Kai; Florescu, Christiane; Herrmann, Sebastian; Bijnens, Bart; Ertl, Georg; Störk, Stefan; Weidemann, Frank

    2016-01-01

    Patients in the early stage of hypertensive heart disease tend to have normal echocardiographic findings. The aim of this study was to investigate whether pathology-specific echocardiographic morphologic and functional parameters can help to detect subclinical hypertensive heart disease. One hundred ten consecutive patients without a history and medication for arterial hypertension (AH) or other cardiac diseases were enrolled. Standard echocardiography and two-dimensional speckle-tracking-imaging analysis were performed. Resting blood pressure (BP) measurement, cycle ergometer test (CET), and 24-hour ambulatory BP monitoring (ABPM) were conducted. Patients were referred to "septal bulge (SB)" group (basal-septal wall thickness ≥ 2 mm thicker than mid-septal wall thickness) or "no-SB" group. Echocardiographic SB was found in 48 (43.6%) of 110 patients. In this SB group, 38 (79.2%) patients showed AH either by CET or ABPM. In contrast, in the no-SB group (n = 62), 59 (95.2%) patients had no positive test for AH by CET or ABPM. When AH was solely defined by resting BP, SB was a reasonable predictive sign for AH (sensitivity 73%, specificity 76%). However, when AH was confirmed by CET or ABPM the echocardiographic SB strongly predicted clinical AH (sensitivity 93%, specificity 86%). In addition, regional myocardial deformation of the basal-septum in SB group was significantly lower than in no-SB group (14 ± 4% vs. 17 ± 4%; P heart disease. Sophisticated BP evaluation including resting BP, ABPM, and CET should be performed in all patients with an accidental finding of a SB in echocardiography. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Clinical profile and echocardiographic findings of patients with cardiomyopathy at a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    Kishor Teple

    2016-01-01

    Full Text Available Cardiomyopathy is a primarily disorder of the heart muscle that causes abnormal myocardial performance and is not the result of disease or dysfunction of other cardiac structures. It is an important and heterogeneous group of diseases. We conducted this study at a tertiary care center with the aim to study the clinical profile and echocardiographic findings of cardiomyopathy patients. This study was a descriptive cross-sectional study conducted over a period of 18 months from September 2013 to August 2015. 50 consecutive patients of cardiomyopathy, attending out-patient department and admitted in tertiary care hospital and meeting inclusion and exclusion criteria were selected. Microsoft Office® Excel software was used for data entry and IBM SPSS 18 was used for descriptive statistics. In our study maximum number of patient belonged to age group of 30 to 49 years (n= 25, 50%. The mean age of presentation was 45.16 years where as mean age for male patients was 45.68 and for female patients was 45.18 years. Male to female ratio was 3.16:1.Dilated cardiomyopathy (n= 26, 52% was most common type of cardiomyopathy. In DCM patients most common symptom was dyspnea (n=26,84.6% and most common sign was pedal edema (n=14,53.8%. Among HCM patients, dyspnea (33.3% was the commonest presenting complaint but large number of patients were asymptomatic (28.6 % and commonest sign was pedal edema (n=5, 23.8%. In DCM patients common ECG findings include Left ventricular hypertrophy (34.6%, Left axis deviation (30.8%, Left bundle branch block (23.1%, atrial fibrillation (23.1%, sinus tachycardia (23.1% and ventricular premature complex (11.5%. Common ECGfinding in HCM patients were Left ventricular hypertrophy (47.6%, giant T wave inversion in V2- V6 (42.9%, Left axis deviation (33.3%, ventricular premature complex (14.3%, Left bundle branch block (9.5% and atrial fibrillation (9.5%. Echocardiography findings for DCM patients in our study were, LV systolic

  16. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    International Nuclear Information System (INIS)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis; Baixas, Cecile; Galinier, Michel; Deken, Valerie; Duhamel, Alain; Remy, Jacques; Remy-Jardin, Martine

    2004-01-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean±SD value: 34±12.9 vs 43±13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean±SD value: 17±2.75 vs 14±3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  17. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis [Department of Radiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Baixas, Cecile; Galinier, Michel [Department of Cardiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Deken, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France); Remy, Jacques; Remy-Jardin, Martine [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France)

    2004-05-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean{+-}SD value: 34{+-}12.9 vs 43{+-}13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean{+-}SD value: 17{+-}2.75 vs 14{+-}3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  18. Echocardiographic reference ranges for sedentary donkeys in the UK.

    Science.gov (United States)

    Roberts, S L; Dukes-McEwan, J

    2016-10-01

    The aim of this study was to provide two-dimensional (2D) and M-mode echocardiographic reference ranges from a sample of the UK population of donkeys including geriatrics (>30 years), owned by The Donkey Sanctuary, and to assess the influence of gender, weight and age on these variables. A total of 36 donkeys with no clinical or echocardiographic evidence of cardiovascular disease were examined; 24 geldings and 12 females, aged 3-45 years old, weighing 130-262 kg. Left atrial to aortic ratio was larger in geldings (P=0.004). There was no significant difference for left ventricular M-mode diastolic diameter between females and geldings (P=0.121) after exclusion of one heavy female outlier. 2D measurements significantly increased with bodyweight including maximal left atrial diameter (R(2)=0.112; P=0.046), aortic diameter at various levels (e.g. annulus: R(2)=0.35; Pdonkeys across a wide age range and shows differences compared with reference ranges from working donkeys. British Veterinary Association.

  19. Echocardiographic findings and joint hypermobility: patients with mitral valve prolapse vs. healthy controls

    Directory of Open Access Journals (Sweden)

    Moradmand S

    2008-11-01

    Full Text Available "nBackground: Mitral valve prolapse is a relatively common valvular abnormality in most communities and joint hypermobility (JHM is also seen in many healthy people as well as in certain clinical disorders, such as Marfan syndrome. The present study was designed to investigate the association between joint hypermobility and mitral valve prolapse (MVP in an Iranian population sample. "nMethods: Fifty-seven patients with nonrheumatic and isolated mitral anterior leaflet prolapse (24 men and 33 women, mean age 23.5 +/-2.3 and 51 healthy subjects (20 men and 31 women, mean age 22.9+/-2.3 were studied. The presence of JHM was evaluated according to the Carter-Wilkinson & Beighton criteria. Echocardiographic examination was performed in all subjects and the correlation between the echocardiographic features of the mitral valve and the hypermobility score were investigated. "nResults: The frequency of JHM in patients with MVP was found to be significantly higher than that of controls (26.3% vs. 7.8%, with mean JHM scores of 3.1+/-2.2 and 1.9+/-1.7, respectively. The patients in the MVP group had significantly increased the anterior mitral leaflet thickness (AMLT, 3.4+/-0.4 mm vs. 3.0+/-0.3 mm; p<0.0005 and maximal leaflet displacement (MLD, 2.4+/-0.3 mm vs. 1.5+/-0.2 mm; p<0.0005 compared to the controls. "nConclusions: We detect a statistically significant relationship between isolated MVP and joint hypermobility as well as between the severity of JHM and echocardiographic features of the mitral leaflets. These results suggest a common etiology for MVP and JHM, which should be investigated in future well-conducted studies.

  20. Echocardiographic assessment with right ventricular function improvement following ultrasound-accelerated catheter-directed thrombolytic therapy in submassive pulmonary embolism.

    Science.gov (United States)

    Doheny, Charles; Gonzalez, Lorena; Duchman, Stanley M; Varon, Joseph; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-06-01

    Introduction The objective of this study was to evaluate the efficacy of ultrasound-accelerated catheter-directed thrombolytic therapy in patients with submassive pulmonary embolism. Methods Clinical records of 46 patients with submassive pulmonary embolism who underwent ultrasound-accelerated catheter-directed pulmonary thrombolysis using tissue plasminogen activator, from 2007 to 2017, were analyzed. All patients experienced clinical symptoms with computed tomography evidence of pulmonary thrombus burden. Right ventricular dysfunction was present in all patients by echocardiographic finding of right ventricle-to-left ventricle ratio > 0.9. Treatment outcome, procedural complications, right ventricular pressures, and thrombus clearance were evaluated. Follow-up evaluation included echocardiographic assessment of right ventricle-to-left ventricle ratio at one month, six months, and one year. Results Technical success was achieved in all patients ( n = 46, 100%). Our patients received an average of 18.4 ± 4.7 mg of tissue plasminogen activator using ultrasound-accelerated thrombolytic catheter with an average infusion time of 16.5± 5.4 h. Clinical success was achieved in all patients (100%). Significant reduction of mean pulmonary artery pressure occurred following the treatment, which decreased from 36 ± 8 to 21 ± 5 mmHg ( p right ventricular dysfunction based on echocardiographic assessment. The right ventricle-to-left ventricle ratio decreased from 1.32 ± 0.18 to 0.91 ± 0.13 at the time of hospital discharge ( p right ventricular function remained improved at 6 months and 12 months of follow-up, as right ventricle-to-left ventricle ratio were 0.92 ± 0.14 ( p right ventricular function in patients with submassive pulmonary embolism.

  1. Echocardiographic chamber quantification in a healthy Dutch population.

    Science.gov (United States)

    van Grootel, R W J; Menting, M E; McGhie, J; Roos-Hesselink, J W; van den Bosch, A E

    2017-12-01

    For accurate interpretation of echocardiographic measurements normative data are required, which are provided by guidelines. For this article, the hypothesis was that these cannot be extrapolated to the Dutch population, since in Dutch clinical practice often higher values are found, which may not be pathological but physiological. Therefore this study aimed to 1) obtain and propose normative values for cardiac chamber quantification in a healthy Dutch population and 2) determine influences of baseline characteristics on these measurements. Prospectively recruited healthy subjects, aged 20-72 years (at least 28 subjects per age decade, equally distributed for gender) underwent physical examination and 2D and 3D echocardiography. Both ventricles and atria were assessed and volumes were calculated. 147 subjects were included (age 44 ± 14 years, 50% female). Overall, feasibility was good for both linear and volumetric measurements. Linear and volumetric parameters were consistently higher than current guidelines recommend, while functional parameters were in line with the guidelines. This was more so in the older population. 3D volumes were higher than 2D volumes. Gender dependency was seen in all body surface area (BSA) corrected volumes and with increasing age, ejection fractions decreased. This study provides 2D and 3D echocardiographic reference ranges for both ventricles and atria derived from a healthy Dutch population. BSA indexed volumes are gender-dependent, age did not influence ventricular volumes and a rise in blood pressure was independently associated with increased right ventricular volumes. The higher volumes found may be indicative for the Dutch population being the tallest in the world.

  2. Can echocardiographic findings predict falls in older persons?

    Directory of Open Access Journals (Sweden)

    Nathalie van der Velde

    Full Text Available BACKGROUND: The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. METHOD AND FINDINGS: In order to determine the association between echocardiographic abnormalities and falls in older adults, we performed a prospective cohort study, in which 215 new consecutive referrals (age 77.4, SD 6.0 of a geriatric outpatient clinic of a Dutch university hospital were included. During the previous year, 139 had experienced a fall. At baseline, all patients underwent routine two-dimensional and Doppler echocardiography. Falls were recorded during a three-month follow-up. Multivariate adjustment for confounders was performed with a Cox proportional hazards model. 55 patients (26% fell at least once during follow-up. The adjusted hazard ratio of a fall during follow-up was 1.35 (95% CI, 1.08-1.71 for pulmonary hypertension, 1.66 (95% CI, 1.01 to 2.89 for mitral regurgitation, 2.41 (95% CI, 1.32 to 4.37 for tricuspid regurgitation and 1.76 (95% CI, 1.03 to 3.01 for pulmonary regurgitation. For aortic regurgitation the risk of a fall was also increased, but non-significantly (hazard ratio, 1.57 [95% CI, 0.85 to 2.92]. Trend analysis of the severity of the different regurgitations showed a significant relationship for mitral, tricuspid and pulmonary valve regurgitation and pulmonary hypertension. CONCLUSIONS: Echo (Doppler cardiography can be useful in order to identify risk indicators for falling. Presence of pulmonary hypertension or regurgitation of mitral, tricuspid or pulmonary valves was associated with a higher fall risk. Our study indicates that the diagnostic work-up for falls in older adults might be improved by adding an echo (Doppler cardiogram in selected groups.

  3. Which echocardiographic parameter is a better marker of volume status in hemodialysis patients?

    Science.gov (United States)

    Sabaghian, Tahereh; Hajibaratali, Bahareh; Samavat, Shiva

    2016-11-01

    Bio-impedance analysis (BIA) is a preferred method for estimating the volume status. However, it cannot be utilized in daily practice. Since the assessment of the volume status is important and challenging for hemodialysis (HD) patients, the aim of study was to determine the volume status in chronic HD patients using echocardiographic parameters and assess its correlation with BIA. In this cross-sectional analysis, echocardiography and BIA were performed on 30 chronic HD patients 30 min before and 30 min after dialysis. All the cases of dialysis were performed in the middle of the week. This study also assessed the correlation between echocardiographic parameters and BIA parameters. There were significant differences between ECW, TBW, and TBW% (TBW/W) before and after HD. Significant differences were observed between echocardiographic parameters of IVCD, IVCDi min , IVCDi max before and after the HD. LVEDD, LVESD, LA area, mitral valve inflow, E/E', and IVRT, were improved after dialysis, too. There was a significant correlation between IVCDi min as an index of volume status, ECW% and TBW% before HD and IVCDi min change after dialysis had a significant correlation with %ECW change after dialysis. Comparison between hypertensive and non-hypertensive groups indicated IVCDi min was significantly lower in non-hypertensive group after dialysis. Our results showed a correlation between IVCDi min and BIA parameters before HD. So, it seems that IVCDi min can be a good parameter for determining the volume status of HD patients. However, further studies, with larger sample size and with a prospective study design, are required to confirm these results.

  4. Echocardiographic assessment of the right ventricle in the current era: Application in clinical practice.

    Science.gov (United States)

    Venkatachalam, Sridhar; Wu, Geru; Ahmad, Masood

    2017-12-01

    The right ventricle has unique structural and functional characteristics. It is now well recognized that the so-called forgotten ventricle is a key player in cardiovascular physiology. Furthermore, there is accumulating evidence that demonstrates right ventricular dysfunction as an important marker of morbidity and mortality in several commonly encountered clinical situations such as heart failure, pulmonary hypertension, pulmonary embolism, right ventricular myocardial infarction, and adult congenital heart disease. In contrast to the left ventricle, echocardiographic assessment of right ventricular function is more challenging as volume estimations are not possible without the use of three-dimensional (3D) echocardiography. Guidelines on chamber quantification provide a standardized approach to assessment of the right ventricle. The technique and limitations of each of the parameters for RV size and function need to be fully understood. In this era of multimodality imaging, echocardiography continues to remain a useful tool for the initial assessment and follow-up of patients with right heart pathology. Several novel approaches such as 3D and strain imaging of the right ventricle have expanded the usefulness of this indispensable modality. © 2017, Wiley Periodicals, Inc.

  5. Echocardiographic Image Quality Deteriorates with Age in Children and Young Adults with Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Power, Alyssa; Poonja, Sabrina; Disler, Dal; Myers, Kimberley; Patton, David J; Mah, Jean K; Fine, Nowell M; Greenway, Steven C

    2017-01-01

    Advances in medical care for patients with Duchenne muscular dystrophy (DMD) have resulted in improved survival and an increased prevalence of cardiomyopathy. Serial echocardiographic surveillance is recommended to detect early cardiac dysfunction and initiate medical therapy. Clinical anecdote suggests that echocardiographic quality diminishes over time, impeding accurate assessment of left ventricular systolic function. Furthermore, evidence-based guidelines for the use of cardiac imaging in DMD, including cardiac magnetic resonance imaging (CMR), are limited. The objective of our single-center, retrospective study was to quantify the deterioration in echocardiographic image quality with increasing patient age and identify an age at which CMR should be considered. We retrospectively reviewed and graded the image quality of serial echocardiograms obtained in young patients with DMD. The quality of 16 left ventricular segments in two echocardiographic views was visually graded using a binary scoring system. An endocardial border delineation percentage (EBDP) score was calculated by dividing the number of segments with adequate endocardial delineation in each imaging window by the total number of segments present in that window and multiplying by 100. Linear regression analysis was performed to model the relationship between the EBDP scores and patient age. Fifty-five echocardiograms from 13 patients (mean age 11.6 years, range 3.6-19.9) were systematically reviewed. By 13 years of age, 50% of the echocardiograms were classified as suboptimal with ≥30% of segments inadequately visualized, and by 15 years of age, 78% of studies were suboptimal. Linear regression analysis revealed a negative correlation between patient age and EBDP score ( r  = -2.49, 95% confidence intervals -4.73, -0.25; p  = 0.032), with the score decreasing by 2.5% for each 1 year increase in age. Echocardiographic image quality declines with increasing age in DMD. Alternate

  6. Rationale and Design of the Echocardiographic Study of Hispanics/Latinos (ECHO-SOL).

    Science.gov (United States)

    Rodriguez, Carlos J; Dharod, Ajay; Allison, Matthew A; Shah, Sanjiv J; Hurwitz, Barry; Bangdiwala, Shrikant I; Gonzalez, Franklyn; Kitzman, Dalane; Gillam, Linda; Spevack, Daniel; Dadhania, Rupal; Langdon, Sarah; Kaplan, Robert

    2015-01-01

    Information regarding the prevalence and determinants of cardiac structure and function (systolic and diastolic) among the various Hispanic background groups in the United States is limited. The Echocardiographic Study of Latinos (ECHO-SOL) ancillary study recruited 1,824 participants through a stratified-sampling process representative of the population-based Hispanic Communities Health Study - Study of Latinos (HCHS-SOL) across four sites (Bronx, NY; Chicago, Ill; San Diego, Calif; Miami, Fla). The HCHS-SOL baseline cohort did not include an echo exam. ECHO-SOL added the echocardiographic assessment of cardiac structure and function to an array of existing HCHS-SOL baseline clinical, psychosocial, and socioeconomic data and provides sufficient statistical power for comparisons among the Hispanic subgroups. Standard two-dimensional (2D) echocardiography protocol, including M-mode, spectral, color and tissue Doppler study was performed. The main objectives were to: 1) characterize cardiac structure and function and its determinants among Hispanics and Hispanic subgroups; and 2) determine the contributions of specific psychosocial factors (acculturation and familismo) to cardiac structure and function among Hispanics. We describe the design, methods and rationale of currently the largest and most comprehensive study of cardiac structure and function exclusively among US Hispanics. ECHO-SOL aims to enhance our understanding of Hispanic cardiovascular health as well as help untangle the relative importance of Hispanic subgroup heterogeneity and sociocultural factors on cardiac structure and function.

  7. Development and Implementation of a Quality Improvement Process for Echocardiographic Laboratory Accreditation.

    Science.gov (United States)

    Gilliland, Yvonne E; Lavie, Carl J; Ahmad, Homaa; Bernal, Jose A; Cash, Michael E; Dinshaw, Homeyar; Milani, Richard V; Shah, Sangeeta; Bienvenu, Lisa; White, Christopher J

    2016-03-01

    We describe our process for quality improvement (QI) for a 3-year accreditation cycle in echocardiography by the Intersocietal Accreditation Commission (IAC) for a large group practice. Echocardiographic laboratory accreditation by the IAC was introduced in 1996, which is not required but could impact reimbursement. To ensure high-quality patient care and community recognition as a facility committed to providing high-quality echocardiographic services, we applied for IAC accreditation in 2010. Currently, there is little published data regarding the IAC process to meet echocardiography standards. We describe our approach for developing a multicampus QI process for echocardiographic laboratory accreditation during the 3-year cycle of accreditation by the IAC. We developed a quarterly review assessing (1) the variability of the interpretations, (2) the quality of the examinations, (3) a correlation of echocardiographic studies with other imaging modalities, (4) the timely completion of reports, (5) procedure volume, (6) maintenance of Continuing Medical Education credits by faculty, and (7) meeting Appropriate Use Criteria. We developed and implemented a multicampus process for QI during the 3-year accreditation cycle by the IAC for Echocardiography. We documented both the process and the achievement of those metrics by the Echocardiography Laboratories at the Ochsner Medical Institutions. We found the QI process using IAC standards to be a continuous educational experience for our Echocardiography Laboratory physicians and staff. We offer our process as an example and guide for other echocardiography laboratories who wish to apply for such accreditation or reaccreditation. © 2016, Wiley Periodicals, Inc.

  8. Abnormal maternal echocardiographic findings in triplet pregnancies presenting with dyspnoea.

    Science.gov (United States)

    Elhenicky, Marie; Distelmaier, Klaus; Mailath-Pokorny, Mariella; Worda, Christof; Langer, Martin; Worda, Katharina

    2016-03-01

    The objective of our study was to evaluate the prevalence of abnormal maternal echocardiographic findings in triplet pregnancies presenting with dyspnoea. Between 2003 and 2013, patients' records of 96 triplet pregnancies at our department were analysed including maternal and fetal outcome, echocardiographic parameters and N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels. After exclusion of triplet pregnancies with fetal demise before 23 + 0 weeks, selective feticide or missing outcome data, the study population consisted of 60 triplet pregnancies. All women with dyspnoea underwent echocardiography and measurement of NT-proBNP. Dyspnoea towards the end of pregnancy was observed in 13.3% (8/60) of all women with triplet pregnancies, and all of these women underwent echocardiography. The prevalence of abnormal echocardiographic findings in women with dyspnoea was 37.5% (3/8) with peripartum cardiomyopathy in one woman. Median serum NT-proBNP was significantly higher in women with abnormal echocardiographic findings compared with those without (1779 ng/ml, range 1045-6076 ng/ml vs 172 ng/ml, range 50-311 ng/ml; p presenting with dyspnoea show a high prevalence of abnormal echocardiographic findings. Since dyspnoea is a common sign in triplet pregnancies and is associated with a high rate of cardiac involvement, echocardiography and evaluation of maternal NT-proBNP could be considered to improve early diagnosis and perinatal management.

  9. Quantification of mitral regurgitation on cardiac computed tomography: comparison with qualitative and quantitative echocardiographic parameters.

    LENUS (Irish Health Repository)

    Arnous, Samer

    2012-02-01

    PURPOSE: To assess whether cardiac computed tomographic angiography (CCTA) can quantify the severity of chronic mitral regurgitation (MR) compared to qualitative and quantitative echocardiographic parameters. MATERIALS AND METHODS: Cardiac computed tomographic angiography was performed in 23 patients (mean +\\/- SD age, 63 +\\/- 16 years; range, 24-86 years) with MR and 20 patients without MR (controls) as determined by transthoracic echocardiography. Multiphasic reconstructions (20 data sets reconstructed at 5% increments of the electrocardiographic gated R-R interval) were used to analyze the mitral valve. Using CCTA planimetry, 2 readers measured the regurgitant mitral orifice area (CCTA ROA) during systole. A qualitative echocardiographic assessment of severity of MR was made by visual assessment of the length of the regurgitant jet. Quantitative echocardiographic measurements included the vena contracta, proximal isovelocity surface area, regurgitant volume, and estimated regurgitant orifice (ERO). Comparisons were performed using the independent t test, and correlations were assessed using the Spearman rank test. RESULTS: All controls and the patients with MR were correctly identified by CCTA. For patients with mild, moderate, or severe MR, mean +\\/- SD EROs were 0.16 +\\/- 0.03, 0.31 +\\/- 0.08, and 0.52 +\\/- 0.03 cm(2) (P < 0.0001) compared with mean +\\/- SD CCTA ROAs 0.09 +\\/- 0.05, 0.30 +\\/- 0.04, and 0.97 +\\/- 0.26 cm(2) (P < 0.0001), respectively. When echocardiographic measurements were graded qualitatively as mild, moderate, or severe, strong correlations were seen with CCTA ROA (R = 0.89; P < 0.001). When echocardiographic measurements were graded quantitatively, the vena contracta and the ERO showed modest correlations with CCTA ROA (0.48 and 0.50; P < 0.05 for both). Neither the proximal isovelocity surface area nor the regurgitant volume demonstrated significant correlations with CCTA ROA. CONCLUSIONS: Single-source 64-slice CCTA provides a

  10. Changes in Mitral Annular Ascent with Worsening Echocardiographic Parameters of Left Ventricular Diastolic Function

    Directory of Open Access Journals (Sweden)

    Paula M. Hernández Burgos

    2016-01-01

    Full Text Available Background. While the mitral annular plane systolic excursion (MAPSE has been suggested as a surrogate measurement of left ventricular ejection fraction, less is known about the relative value of mitral annular ascent (MAa. Methods. Our database was queried for complete transthoracic echocardiograms performed for any clinical indication. Baseline echocardiographic measurements were compared to determine any correlation between MAa and traditional Echo-Doppler echocardiographic measures to characterize left ventricular diastolic dysfunction (LVDD. Results. Patients with normal LV diastolic function were younger (41±13 years than patients with LVDD (stage 1: 61±13 years; stage 2: 57±14 years; and stage 3: 66±17 years; p=0.156. LV ejection fraction decreased in patients with stage 2 LVDD (63±17% and was further reduced in patients with stage 3 LVDD (28±21; p=0.003. Discussion. While a vigorous MAa excursion was seen in patients with stage 1 LVDD, MAa significantly decreased in stage 2 and stage 3 LVDD patients. Our results highlight the importance of atrioventricular coupling, as MAa motion seems to reflect changes in left atrial pressure. Additional studies are now required to better examine atrioventricular interactions and electromechanical coupling that might improve our assessment of LV diastolic function.

  11. Echocardiographic findings in haemodialysis patients according to their state of hydration

    Directory of Open Access Journals (Sweden)

    María Cristina Di Gioia

    2017-01-01

    Conclusions: We found that left atrial volume index determined by echocardiographic Area-length method, but not left ventricle hypertrophy or dimensions of cavities, are related on hydration status based on bioimpedance measured time-averaged fluid overload (TAFO, and not with FO/ECW.

  12. Echocardiographic versus histologic findings in Marfan syndrome.

    Science.gov (United States)

    Gu, Xiaoyan; He, Yihua; Li, Zhian; Han, Jiancheng; Chen, Jian; Nixon, J V Ian

    2015-02-01

    This retrospective study attempted to establish the prevalence of multiple-valve involvement in Marfan syndrome and to compare echocardiographic with histopathologic findings in Marfan patients undergoing valvular or aortic surgery. We reviewed echocardiograms of 73 Marfan patients who underwent cardiovascular surgery from January 2004 through October 2009. Tissue histology was available for comparison in 29 patients. Among the 73 patients, 66 underwent aortic valve replacement or the Bentall procedure. Histologic findings were available in 29 patients, all of whom had myxomatous degeneration. Of 63 patients with moderate or severe aortic regurgitation as determined by echocardiography, 4 had thickened aortic valves. The echocardiographic findings in 18 patients with mitral involvement included mitral prolapse in 15. Of 11 patients with moderate or severe mitral regurgitation as determined by echocardiography, 4 underwent mitral valve repair and 7 mitral valve replacement. Histologic findings among mitral valve replacement patients showed thickened valve tissue and myxomatous degeneration. Tricuspid involvement was seen echocardiographically in 8 patients, all of whom had tricuspid prolapse. Two patients had severe tricuspid regurgitation, and both underwent repair. Both mitral and tricuspid involvement were seen echocardiographically in 7 patients. Among the 73 patients undergoing cardiac surgery for Marfan syndrome, 66 had moderate or severe aortic regurgitation, although their valves manifested few histologic changes. Eighteen patients had mitral involvement (moderate or severe mitral regurgitation, prolapse, or both), and 8 had tricuspid involvement. Mitral valves were most frequently found to have histologic changes, but the tricuspid valve was invariably involved.

  13. The role of biomedical knowledge in echocardiographic interpretation expertise development: a correlation study

    DEFF Research Database (Denmark)

    Nielsen, Dorte Guldbrand; Gøtzsche, Ole; Eika, Berit

    2010-01-01

    Purpose: Little is known about factors of relevance for achieving knowledge of echocardiography (TTE); one of the essential skills defined by the European Society of Cardiology Core Curriculum. Recent research in other fields suggests that biomedical knowledge plays a more prominent role in profe......Purpose: Little is known about factors of relevance for achieving knowledge of echocardiography (TTE); one of the essential skills defined by the European Society of Cardiology Core Curriculum. Recent research in other fields suggests that biomedical knowledge plays a more prominent role...... in professional practice than previously assumed. This study investigates the role of biomedical knowledge represented by physiology knowledge in the development of echocardiographic expertise. Methods: Forty-five physicians (15 novices, 15 intermediates and 15 experts) were evaluated on echocardiography...... interpretation skills. An anatomical focused checklist was developed based on Danish Cardiology Society guidelines for a standard echocardiography of adults. A TTE case of a common and complex clinical presentation was recorded and presented to participants on a portable computer using EchoPac software...

  14. [Spongy cardiomyopathy in an elderly woman. Echocardiographic description].

    Science.gov (United States)

    Canale, Jesús; Cortés Lawrenz, Jorge; Moreno Valenzuela, Francisco Germán

    2005-01-01

    Isolated left ventricular noncompaction, also known as spongy myocardium or spongy cardiomyopathy, is a recently described congenital disease caused by an arrest in the left ventricular myocardial embriogenesis that makes the ventricular wall to persist thickened with multiple trabecular formations and deep sinusoidal recesses. It is clinically characterized by heart failure, cardiac arrhythmia and systemic embolic events. Most of the affected subjects are detected during childhood or adolescence, others in the adult life but very few elderly patients have been reported in the worldwide medical literature. We here report the case of a 75-year-old woman that is one of the oldest patients ever reported, whose clinical picture and echocardiographic findings are typical of this modality of cardiomyopathy. We do comments on this case in regard to the most relevant facts that appear in the limited medical literature about this interesting disease.

  15. Safety and usefulness of outreach clinic conducted by pediatric echosonographers

    International Nuclear Information System (INIS)

    Al Harbi, Badr; Al Akhfash, Ali A.; Al Ghamdi, Abdullah; Al-Mesned, Abdulrahman

    2012-01-01

    Outreach echocardiographic services led by cardiac sonographers may help district level hospitals in the management of patients suspected to have cardiac anomalies. However, the safety and utility of such an approach is not tested. We retrospectively reviewed our experience of patients seen in the outreach visits by the echocardiographers alone and subsequently reviewed in the pediatric cardiology clinic. Comparison between the diagnosis made by the echocardiographer and the consultant pediatric cardiologist were done. We defined safety as no change in patient management plan between the outreach evaluation and the pediatric cardiology clinic evaluation, and we defined usefulness as being beneficial, serviceable and of practical use. Two senior echocardiographic technicians did 41 clinic visits and over a period of 17 months, 623 patients were seen. Patients less than 3 months of age constitute 63% of the total patients seen. Normal echocardiographic examinations were found in 342 (55%) of patients. These patients were not seen in our cardiology clinic. Abnormal echocardiographic examinations were found in 281 (45%) of patients. Among the 281 patients with abnormal echos in the outreach visits, 251 patients (89.3%) were seen in the pediatric cardiology clinic. Comparing the results of the outreach clinic evaluation to that of the pediatric cardiology clinic, 73 patients (29%) diagnosed to have a minor CHD turned to have normal echocardiographic examinations. In all patients seen in both the outreach clinics and the pediatric tertiary cardiac clinics there was no change in patient's management plan. Outreach clinic conducted by pediatric echo sonographers could be useful and safe. It may help in reducing unnecessary visits to pediatric cardiology clinics, provide parental reassurance, and help in narrowing the differential diagnosis in critically ill patient unable to be transferred to tertiary cardiac centers provided it is done by experienced echosonographers

  16. An echocardiographic study of healthy Border Collies with normal reference ranges for the breed.

    Science.gov (United States)

    Jacobson, Jake H; Boon, June A; Bright, Janice M

    2013-06-01

    The objectives of this study were to obtain standard echocardiographic measurements from healthy Border Collies and to compare these measurements to those previously reported for a general population of dogs. Standard echocardiographic data were obtained from twenty apparently healthy Border Collie dogs. These data (n = 20) were compared to data obtained from a general population of healthy dogs (n = 69). Border Collies were deemed healthy based on normal history, physical examination, complete blood count, serum biochemical profile, electrocardiogram, and blood pressure, with no evidence of congenital or acquired heart disease on echocardiographic examination. Standard two dimensional, M-mode, and Doppler echocardiographic measurements were obtained and normal ranges determined. The data were compared to data previously obtained at our hospital from a general population of normal dogs. Two dimensional, M-mode, and Doppler reference ranges for healthy Border Collies are presented in tabular form. Comparison of the weight adjusted M-mode echocardiographic means from Border Collies to those from the general population of dogs showed Border Collies to have larger left ventricular systolic and diastolic dimensions, smaller interventricular septal thickness, and lower fractional shortening. There are differences in some echocardiographic parameters between healthy Border Collies and the general dog population, and the echocardiographic reference ranges provided in this study should be used as breed specific reference values for Border Collies. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.

  18. Finite-element-method (FEM model generation of time-resolved 3D echocardiographic geometry data for mitral-valve volumetry

    Directory of Open Access Journals (Sweden)

    Kikinis Ron

    2006-03-01

    Full Text Available Abstract Introduction Mitral Valve (MV 3D structural data can be easily obtained using standard transesophageal echocardiography (TEE devices but quantitative pre- and intraoperative volume analysis of the MV is presently not feasible in the cardiac operation room (OR. Finite element method (FEM modelling is necessary to carry out precise and individual volume analysis and in the future will form the basis for simulation of cardiac interventions. Method With the present retrospective pilot study we describe a method to transfer MV geometric data to 3D Slicer 2 software, an open-source medical visualization and analysis software package. A newly developed software program (ROIExtract allowed selection of a region-of-interest (ROI from the TEE data and data transformation for use in 3D Slicer. FEM models for quantitative volumetric studies were generated. Results ROI selection permitted the visualization and calculations required to create a sequence of volume rendered models of the MV allowing time-based visualization of regional deformation. Quantitation of tissue volume, especially important in myxomatous degeneration can be carried out. Rendered volumes are shown in 3D as well as in time-resolved 4D animations. Conclusion The visualization of the segmented MV may significantly enhance clinical interpretation. This method provides an infrastructure for the study of image guided assessment of clinical findings and surgical planning. For complete pre- and intraoperative 3D MV FEM analysis, three input elements are necessary: 1. time-gated, reality-based structural information, 2. continuous MV pressure and 3. instantaneous tissue elastance. The present process makes the first of these elements available. Volume defect analysis is essential to fully understand functional and geometrical dysfunction of but not limited to the valve. 3D Slicer was used for semi-automatic valve border detection and volume-rendering of clinical 3D echocardiographic

  19. Echocardiographic predictors of early in-hospital heart failure during first ST-elevation acute myocardial infarction: does myocardial performance index and left atrial volume improve diagnosis over conventional parameters of left ventricular function?

    Directory of Open Access Journals (Sweden)

    Machado Cristiano V

    2011-06-01

    Full Text Available Abstract Background Left ventricular ejection fraction (LVEF has been considered a major determinant of early outcome in acute myocardial infarction (AMI. Myocardial performance index (MPI has been associated to early evolution in AMI in a heterogeneous population, including non ST-elevation or previous AMI. Left atrial volume has been related with late evolution after AMI. We evaluated the independent role of clinical and echocardiographic variables including LVEF, MPI and left atrial volume in predicting early in-hospital congestive heart failure (CHF specifically in patients with a first isolated ST-elevation AMI. Methods Echocardiography was performed within 30 hours of chest pain in 95 patients with a first ST-elevation AMI followed during the first week of hospitalization. Several clinical and echocardiographic variables were analyzed. CHF was defined as Killip class ≥ II. Multivariate regression analysis was used to select independent predictor of in-hospital CHF. Results Early in-hospital CHF occurred in 29 (31% of patients. LVEF ≤ 0.45 was the single independent and highly significant predictor of early CHF among other clinical and echocardiographic variables (odds ratio 17.0; [95% CI 4.1 - 70.8]; p Conclusion For patients with first, isolated ST-elevation AMI, LVEF assessed by echocardiography still constitutes a strong and accurate independent predictor of early in-hospital CHF, superior to isolated MPI and left atrial volume in this particular subset of patients.

  20. New echocardiographic predictors of clinical outcome in patients presenting with heart failure and a preserved left ventricular ejection fraction: a subanalysis of the Ka (Karolinska) Ren (Rennes) Study.

    Science.gov (United States)

    Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Hage, Camilla; Persson, Hans; Reynaud, Amélie; Ennezat, Pierre-Vladimir; Bauer, Fabrice; Drouet, Elodie; Linde, Cecilia; Daubert, Claude

    2015-07-01

    To identify electrocardiographic and echocardiographic predictors of mortality and hospitalizations for heart failure (HF) in the KaRen study. KaRen is a prospective, observational study of the long-term outcomes of patients presenting with heart failure and a preserved ejection fraction (HFpEF). We identified 538 patients who presented with acute cardiac decompensation, a >100 pg/mL serum b-type natriuretic peptide (BNP) or >300 pg/mL N-terminal pro-brain natriuretic peptide (NT-proBNP) concentration and a left ventricular ejection fraction (LVEF) >45%. After 4-8 weeks of standard treatment, 413 patients (mean age = 76 ± 9 years, 55.9% women) returned for analyses of their clinical status, laboratory screen, and detailed electrocardiographic and Doppler echocardiographic recordings. They were followed for a mean of 28 months thereafter. The primary study endpoint was time to death from all causes or first hospitalization for heart failure. Mean LVEF was 62.4 ± 6.9% and median NT-proBNP 1410 pmol/L. PR interval >200 ms was present in 11.2% of patients and 14.9% had a >120 ms QRS duration, with left bundle branch block in only 6.3%. Over a mean follow-up of 28 months, 177 patients (42.9%) reached a primary study endpoint, including 61 deaths and 116 hospitalizations for heart failure. After adjustment for age, gender, New York Heart Association class, atrial fibrillation history, creatinine, sodium, BNP, ejection fraction, and right ventricular fractional shortening, only E/e' remained as a predictor, with a hazard ratio = 1.49 and P = 0.0012. The incidence of hospitalizations for HF and deaths in KaRen was high and E/e' predicted adverse clinical outcomes. These observations should help in the risk stratification and therapy of HFpEF. © 2015 The Authors. European Journal of Heart Failure © 2015 European Society of Cardiology.

  1. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    Science.gov (United States)

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients 10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  2. Correlation analysis of the relationship between B-type natriuretic peptide and selected echocardiographic parameters in patients with permanent pacemakers

    Directory of Open Access Journals (Sweden)

    Janusz Sielski

    2016-01-01

    Full Text Available Introduction: The present study was undertaken to evaluate the practical value of BNP measurements and echocardiographic left ventricular volume index in patients with permanent pacemakers because there are no such reports in the literature. Aim of the research: The aim of the study was to reveal multiple correlations between BNP levels and selected echocardiographic parameters of the left atrium in patients with permanent pacemakers. In the literature there are reports on the significance of BNP values and left atrial size in patients with permanent pacemakers. The results of the present study appear to be of value in the outpatient assessment of these patients. Material and methods: We analysed a group of 117 patients with permanent pacemakers (AAI/R 21 patients, DDD/R 59 patients, VVI/R 37 patients and 48 healthy volunteers serving as the control group. BNP measurements were performed on venous blood samples using Triage meters. The Simpson method and the ellipse method were used to assess the left atrium on echocardiography. Results: There was a significant correlation between BNP and maximum left atrial volume, minimum left atrial volume, and left atrial volume index in patients with AAI/R, DDD/R, and VVI/R pacemakers at 3 and 6 months after the implantation. Conclusions : In patients after implantation of permanent pacemakers there are correlations between BNP values and echocardiographic left atrial parameters, especially in patients with DDD/R pacemakers. Left atrial function improves in patients with DDD/R pacemakers. Pacemaker check-up should be extended to include BNP measurements and echocardiographic assessment of the left atrium.

  3. Echocardiographic evaluation of the arterial stiffness in healthy subjects and hypertensive patients under 60 years

    International Nuclear Information System (INIS)

    Valiente Mustelier, Juan; Suarez Vazquez, Leisy; Cabrera Rego, Julio Oscar; Gandarilla Sarmientos, Julio Cesar

    2011-01-01

    We conducted a cross-sectional study that included 83 patients (healthy, n=43; hypertensive, n=40) assisted in the external consultation of the National Cardiology and Cardiovascular Surgery Institute, from April to October, 2009. We included clinical (age, sex, personal antecedents of smoking habit, obesity, hypercholesterolemia, arterial hypertension) and echocardiographic (diastolic function, arterial stiffness index [β], pressure strain elastic modulus [Ep], arterial compliance, local pulse wave velocity [LPWV]) variables

  4. Echocardiographic phase imaging to predict reverse remodeling after cardiac resynchronization therapy.

    Science.gov (United States)

    Buss, Sebastian J; Humpert, Per M; Bekeredjian, Raffi; Hardt, Stefan E; Zugck, Christian; Schellberg, Dieter; Bauer, Alexander; Filusch, Arthur; Kuecherer, Helmut; Katus, Hugo A; Korosoglou, Grigorios

    2009-05-01

    The aim of our study was to investigate whether echocardiographic phase imaging (EPI) can predict response in patients who are considered for cardiac resynchronization therapy (CRT). CRT improves quality of life, exercise capacity, and outcome in patients with bundle-branch block and advanced heart failure. Previous studies used QRS duration to select patients for CRT; the accuracy of this parameter to predict functional recovery, however, is controversial. We examined 42 patients with advanced heart failure (New York Heart Association [NYHA] functional class III to IV, QRS duration >130 ms, and ejection fraction or=15% at 6 to 8 months of follow-up were defined as responders. All others were classified as nonresponders. The Ts-SD and the mean EPI-Index were related to Delta ESV (r = 0.43 for Ts-SD and r = 0.67 for mean EPI-Index, p < 0.01 for both), and both parameters yielded similar accuracy for the prediction of LV remodeling (area under the curve of 0.87 for TDI vs. 0.90 for EPI, difference between areas = 0.03, p = NS) and ejection fraction (EF) improvement (area under the curve of 0.87 for TDI vs. 0.93 for EPI, difference between areas = 0.06, p = NS). Furthermore, patients classified as responders by EPI (mean EPI-Index Echocardiographic phase imaging can predict functional recovery, reverse LV remodeling, and clinical outcomes in patients who undergo CRT. EPI is a method that objectively and accurately quantifies LV dyssynchrony and seems to be noninferior to TDI for the prediction of reverse LV remodeling and functional recovery.

  5. Rapid estimation of left ventricular ejection fraction in acute myocardial infarction by echocardiographic wall motion analysis

    DEFF Research Database (Denmark)

    Berning, J; Rokkedal Nielsen, J; Launbjerg, J

    1992-01-01

    Echocardiographic estimates of left ventricular ejection fraction (ECHO-LVEF) in acute myocardial infarction (AMI) were obtained by a new approach, using visual analysis of left ventricular wall motion in a nine-segment model. The method was validated in 41 patients using radionuclide...

  6. Natural history of severe atheromatous disease of the thoracic aorta: a transesophageal echocardiographic study.

    Science.gov (United States)

    Montgomery, D H; Ververis, J J; McGorisk, G; Frohwein, S; Martin, R P; Taylor, W R

    1996-01-01

    This study sought to prospectively observe the morphologic and clinical natural history of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography. Atherosclerosis of the thoracic aorta has been shown to be highly associated with risk for embolic events in transesophageal studies, but the natural history of the disease under clinical conditions has not been reported. During a 20-month period, 191 of 264 patients undergoing transesophageal echocardiography had adequate visualization of the aorta to allow atherosclerotic severity to be graded as follows: grade I = normal (44 patients); grade II = intimal thickening (52 patients); grade III = atheroma or = 5 mm (19 patients); grade V = mobile lesion (14 patients). All available patients with grades IV (8 patients) and V (10 patients) disease as well as a subgroup of 12 patients with grade III disease had follow-up transesophageal echocardiographic studies (mean [+/- SD] 11.7 +/- 0.9 months, range 6 to 22). Of 30 patients undergoing follow-up transesophageal echocardiographic studies, 20 (66%) had no change in atherosclerotic severity grade. Of the remaining 10 patients, atherosclerotic severity progressed one grade in 7 and decreased in 3 with resolved mobile lesions. Of 18 patients with grade IV or V disease of the aorta who underwent a follow-up study, 11 (61%) demonstrated formation of new mobile lesions. Of 10 patients with grade V disease on initial study who underwent follow-up study, 7 (70%) demonstrated resolution of a specific previously documented mobile lesion. However, seven patients (70%) with grade V disease also demonstrated development of a new mobile lesion. Of 33 patients with grade IV or V disease, 8 (24%) died during the study period, and 1 (3%) had a clinical embolic event. The presence of severe atherosclerotic disease of the thoracic aorta as defined by transesophageal echocardiography is associated with a high mortality rate. Although the morphologic

  7. Clinical and echocardiographic features of primary infundibular stenosis with intact ventricular septum in dogs.

    Science.gov (United States)

    Minors, Sandra L; O'Grady, Michael R; Williams, Regan M; O'Sullivan, M Lynne

    2006-01-01

    Primary infundibular stenosis is a rare congenital defect in which the right ventricle is divided into a proximal "high-pressure" chamber and a distal "low-pressure" chamber. The condition can be misdiagnosed as ventricular septal defect or valvular pulmonic stenosis and the disease severity underestimated. The purpose of this study was to provide a detailed clinical and echocardiographic description of this anomaly in a series of dogs. Several anatomic forms of infundibular stenosis exist. High resolution two-dimensional echocardiography could differentiate 3 gross anatomic substrates. Knowledge of the anatomy of the obstructing lesion could influence options for corrective interventions. Thirteen dogs examined at the Ontario Veterinary College teaching hospital from 1994 to 2005 with an ultrasound diagnosis of subpulmonic stenasis. A retrospective review was made of case records from 1994 to 2005. Thirteen dogs were identified as having primary infundibular stenosis, with apparent increased prevalence in Golden Retrievers (8/13, 62%) and Siberian Huskies (3/13, 23%). Three types of infundibular lesions were identified by ultrasound in 11/13 dogs: a fibrous diaphragm (6), fibromuscular (4), and muscular obstruction (1). Two dogs with a fibrous diaphragm underwent direct surgical dilation without the use of cardiopulmonary bypass or inflow occlusion, resulting in substantial reduction of the severity of stenosis. Accurate determination of the severity of the stenosis and the anatomy of the obstructing lesion are important in devising a treatment strategy. Recognition of the fibrous diaphragm by echocardiography identifies a subset of dogs potentially amenable to surgical dilation without the need for cardiopulmonary bypass.

  8. Echocardiographic reference ranges in older children and adolescents in sub-Saharan Africa.

    Science.gov (United States)

    Majonga, Edith D; Rehman, Andrea M; McHugh, Grace; Mujuru, Hilda A; Nathoo, Kusum; Patel, Mohammad S; Munyati, Shungu; Odland, Jon O; Kranzer, Katharina; Kaski, Juan P; Ferrand, Rashida A

    2017-12-01

    Echocardiographic reference ranges are important to identify abnormalities of cardiac dimensions. Reference ranges for children in sub-Saharan Africa have not been established. The aim of this study was to establish echocardiographic z-score references for Black children in sub-Saharan Africa. 282 healthy subjects aged 6-16years (143 [51%] males) with no known history of cardiac disease were enrolled in the study in Harare, Zimbabwe between 2014 and 2016. Standard M-mode echocardiography was performed and nine cardiac chamber dimensions were obtained. Two non-linear statistical models (gamma weighted model and cubic polynomial model) were tested on the data and the best fitting model was used to calculate z-scores of these cardiac chamber measures. The reference ranges are presented on scatter plots against BSA. Normative data for the following cardiac measures were obtained and z-scores calculated: right ventricular diameter at end diastole (RVEDD); left ventricular diameter at end diastole (LVEDD) and systole (LVESD); interventricular septal wall thickness at end diastole (IVSd) and systole (IVSs); left ventricular posterior wall thickness at end diastole (LVPWd) and systole (LVPWs); left atrium diameter at end systole (LA) and tricuspid annular plane systolic excursion (TAPSE). Girls had higher values for BMI and heart rate than boys (p=0.048 and p=0.001, respectively). Mean interventricular septal and left ventricular posterior walls thickness was higher than published normal values in predominantly Caucasian populations. These are the first echocardiographic reference ranges for children from sub Saharan Africa and will allow accurate assessment of cardiac dimensions in clinical practice. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Implementation of the stress echocardiography in an echocardiographic laboratory

    International Nuclear Information System (INIS)

    Solis Brizuela, Felix

    2013-01-01

    The logistics for the implementation of the stress echocardiography is defined with based on current recommendations, for an echocardiography laboratory. The protocols established to perform the studies and procedures of this diagnostic method are exposed. The elementary conditions to realize with safety the stress echocardiography are established. Recent literature on the evaluation of new echocardiographic techniques is reviewed to determine their usefulness in stress testing. The assessment of stress echocardiography is developed. The stress echocardiography has been the procedure with high sensitivity and specificity for the diagnosis of coronary artery disease [es

  10. Intrapulmonary arteriovenous anastomoses in dogs with severe Angiostrongylus vasorum infection: clinical, radiographic, and echocardiographic evaluation.

    Science.gov (United States)

    Novo Matos, J; Malbon, A; Dennler, M; Glaus, T

    2016-06-01

    In both humans and dogs the pulmonary vasculature is able to recruit large-diameter anatomical intrapulmonary arteriovenous anastomoses (IPAVAs). In healthy people the opening of these anastomoses affects the degree of exercise-induced increase in pulmonary arterial pressure. The presence of these IPAVAs can be demonstrated using saline contrast echocardiography. The aims of the present study were to characterize severely affected, naturally infected dogs with Angiostrongylus vasorum, to evaluate if these dogs can open IPAVAs, and to assess if the recruitment of such anastomoses affects the severity of pulmonary hypertension (PH). Eight client-owned dogs with severe A. vasorum infection were recruited. Dogs with A. vasorum infection that presented with severe dyspnea and/or syncope were prospectively screened by echocardiography for the presence of PH and IPAVAs. Only severely affected dogs, based on a combination of clinical, radiographic and echocardiographic abnormalities, were enrolled. Opening of IPAVAs could be demonstrated in three dogs with no to moderate PH, and could not be demonstrated in five dogs with severe PH. In two dogs thoracic radiographs showed only mild interstitial changes, while computer tomography and postmortem examination revealed severe pulmonary interstitial and vascular disease. These results suggest that dogs may open IPAVAs and that opening of such anastomoses may play a regulatory role in the development of PH. There may be a marked discrepancy between radiographic changes and disease severity in A. vasorum. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Frequency of echocardiographic complications of dilated cardiomyopathy at a tertiary care hospital

    International Nuclear Information System (INIS)

    Rashid, A.; Ahmed, H.N.; Ahmed, N.

    2012-01-01

    Dilated cardiomyopathy can lead to a variety of complications recognisable on clinical, echocardiographic, electrocardiographic and radiographic assessment. Among this, transthoracic echocardiography has the dual advantage of being helpful in making the diagnosis of dilated cardiomyopathy as well as an effective tool in early recognition of certain complications for timely management to improve the quality of life of these patients. Methods: This descriptive (case series) study was undertaken at departments of medicine, cardiology, paediatrics and obs/gyn, Ayub Teaching Hospital, Abbottabad from July to December, 2008. fifty patients of dilated cardiomyopathy without age and gender discrimination were selected by convenience sampling. Those with hypertrophic and restrictive cardiomyopathies, valvular and congenital heart disease, hypertension and ischemic heart disease were excluded. Results: mean age was 47.12 +- 17.9 year with male predominance (males=34, females=16). Mean ejection fraction was 30.6 +- 6.9%. complications revealed on echocardiography were intracardiac thrombi (5, 10%), spontaneous echo contrast (5, 10%), pericardial effusion (6, 12%), mitral regurgitation (46, 92%), tricuspid (25, 50%), aortic (5, 10%), pulmonary (2, 4%) multi-valvular regurgitation (28, 56%), and left atrial dilatation (36, 72%). Conclusion: lv systolic dysfunction, cardiac thrombi, spontaneous echo contrast, mitral and tricuspid regurgitation and left atrial enlargement are important complications of dilated cardiomyopathy. echocardiography is important tool towards identification of these complications. (author)

  12. Ia diastolic dysfunction: an echocardiographic grade.

    Science.gov (United States)

    Pandit, Anil; Mookadam, Farouk; Hakim, Fayaz A; Mulroy, Eoin; Saadiq, Rayya; Doherty, Mairead; Cha, Stephen; Seward, James; Wilansky, Susan

    2015-01-01

    To demonstrate that a distinct group of patients with Grade Ia diastolic dysfunction who do not conform to present ASE/ESE diastolic grading exists. Echocardiographic and demographic data of the Grade Ia diastolic dysfunction were extracted and compared with that of Grades I and II in 515 patients. The mean of age of the cohort was 75 ± 9 years and body mass index did not differ significantly between the 3 groups (P = 0.45). Measurements of left atrial volume index (28.58 ± 7 mL/m(2) in I, 33 ± 10 mL/m(2) in Ia, and 39 ± 12 mL/m(2) in II P Ia, and 79 ± 15 msec in II P Ia, and 217 ± 57 msec in II P Ia, and 22 ± 8 in II), and lateral E/e' (8 ± 3 in I, 15 ± 6 in Ia, and 18 ± 9 in II P Ia compared with I and II. These findings remained significant even after adjusting for age, gender, diabetes, and smoking. Patients with echocardiographic characteristics of relaxation abnormality (E/A ratio of Ia group. © 2014, Wiley Periodicals, Inc.

  13. Common echocardiographic abnormalities in Nigerians of different ...

    African Journals Online (AJOL)

    2012-09-17

    Sep 17, 2012 ... artery disease, cardiac murmurs, atrial fibrillation, stroke, and transient ischaemic attack.[4,5] In some circumstances, the examination is an appropriate screening test even in the absence of cardiovascular symptoms, especially. Common echocardiographic abnormalities in. Nigerians of different age groups.

  14. Making three-dimensional echocardiography more tangible: a workflow for three-dimensional printing with echocardiographic data

    Directory of Open Access Journals (Sweden)

    Azad Mashari MD

    2016-12-01

    Full Text Available Three-dimensional (3D printing is a rapidly evolving technology with several potential applications in the diagnosis and management of cardiac disease. Recently, 3D printing (i.e. rapid prototyping derived from 3D transesophageal echocardiography (TEE has become possible. Due to the multiple steps involved and the specific equipment required for each step, it might be difficult to start implementing echocardiography-derived 3D printing in a clinical setting. In this review, we provide an overview of this process, including its logistics and organization of tools and materials, 3D TEE image acquisition strategies, data export, format conversion, segmentation, and printing. Generation of patient-specific models of cardiac anatomy from echocardiographic data is a feasible, practical application of 3D printing technology.

  15. Parâmetros ecocardiográficos em modo unidimensional de cães da raça Poodle miniatura, clinicamente sadios Echocardiographic parameters in unidimensional mode from clinically normal miniature Poodle dogs

    Directory of Open Access Journals (Sweden)

    Ronaldo Jun Yamato

    2006-02-01

    Full Text Available No Brasil, a população canina da raça Poodle, principalmente a variação miniatura, cresce em progressão geométrica, sendo esta raça freqüentemente acometida por cardiopatias congênitas e adquiridas. O escopo deste estudo foi padronizar e avaliar os parâmetros ecocardiográficos em modo unidimensional (M de cães da raça Poodle miniatura, devido ao aumento populacional da mesma, a variação existente destes parâmetros entre as raças caninas e as diversas cardiopatias às quais os Poodles são predispostos. Foram utilizados 30 cães, da referida raça, sendo 09 machos e 21 fêmeas com idades entre 2 a 7 anos (3,87±1,55 e peso corpóreo variando de 2,0 a 8,7 quilos (4,49±1,38. Os cães incluídos neste estudo foram considerados sadios, após terem sido submetidos aos exames físico, laboratoriais, eletrocardiográfico, radiográfico e à mensuração da pressão arterial. Após a realização do exame ecocardiográfico e a análise dos resultados, foi possível obter os valores de referência do exame ecocardiográfico, em modo M, para os cães da raça Poodle miniatura e, ainda, sugerir que o peso corpóreo e altura podem exercer influência sobre os parâmetros ecocardiográficos.In Brazil, the canine population of the Poodle, mainly the Miniature variation, grows in geometric progression, beeing this breed frequently affected by congenital and adquired cardiopathies. The main objective of this study was the standardization and evaluation of the echocardiographic parameters in unidimensional (M mode, from clinically normal Miniature Poodle dogs. Thirthy Miniature Poodle dogs, 09 males and 21 females ageing between 2 and 7 years old (3.87±1.55, and weight varying from 2.0 to 8.7 kilogram (4.49±1.38 were studied. To be included in this study, physical exam, hemogram, biochemical profile, urinalysis, detection of circulating microfilaries as well as ELISA test for Dirofilaria immitis, electrocardiographic, radiographic exams and

  16. Two dimensional and Doppler echocardiographic evaluation of patients presenting at Obafemi Awolowo University Teaching Hospitals Complex Ile Ife Nigeria a prospective study of 2501 subjects

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2013-07-01

    Full Text Available Rasaaq Ayodele Adebayo,1 Patience Olayinka Akinwusi,2 Michael Olabode Balogun,1 Anthony Olubunmi Akintomide,1 Victor Oladeji Adeyeye,1 Olugbenga Olusola Abiodun,1 Luqman Adeleke Bisiriyu,3 Suraj Adefabi Ogunyemi,1 Ebenezer Adekunle Ajayi,4 Olufemi Eyitayo Ajayi,1 Adebayo Tolulope Oyedeji5 1Cardiology Unit, Department of Medicine, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, 2Cardiology Unit, Department of Medicine, Osun State University, Osogbo, Osun State, 3Department of Demography and Social Statistics, Obafemi Awolowo University, Ile-Ife, Osun State, 4Cardiology Unit, Department of Medicine, Ekiti State University Teaching Hospital, Ado-Ekiti, Ekiti State, 5Cardiology Unit, Department of Medicine, LAUTECH Teaching Hospital, Osogbo, Osun State, Nigeria Background: Echocardiography remains a key noninvasive cardiac investigative tool in the management of patients, especially in a developing economy like Nigeria. In this study, we investigated the indications for transthoracic echocardiography and spectrum of cardiac disease found in patients referred to our cardiac unit for echocardiography. Methods: A prospective two-dimensional, pulsed, continuous, and color-flow Doppler echocardiographic evaluation was done using the transthoracic approach in 2501 patients over an eight-year period. Univariate data analysis was performed for mean age, gender, clinical indications, and diagnoses. Results: The subject age range was less than 12 months to 97 years (mean 52.39 years. There were 1352 (54.06% males and 1149 (45.94% females. The most common indication for echocardiography was hypertension (52.1% followed by congestive cardiac failure (13.9%. Others were for screening (6.1%, arrhythmias (5%, cerebrovascular disease (5%, chest pain (3.3%, chronic kidney disease (3.2%, congenital heart disease (2.6%, cardiomyopathy (1.8%, rheumatic heart disease (1.7%, diabetes mellitus (1.3%, thyrocardiac disease (1.2%, ischemic heart

  17. [Study of echocardiographic parameters of rheumatoid arthritis black African without clinically evident cardiovascular manifestations: A cross-sectional study of 73 cases in Senegal].

    Science.gov (United States)

    Dodo-Siddo, M N; Diao, M; Ndiaye, M B; Ndongo, S; Kane, A; Mbaye, A; Bodian, M; Sarr, S A; Sarr, M; Ba, S; Diop, T M

    2016-04-01

    Research of cardiac involvement in patients with rheumatoid arthritis can prevent complications and place in a logical secondary prevention. The objective of this study was to investigate the echocardiographic parameters in a population of Senegalese patients with rheumatoid arthritis without clinically evident cardiovascular manifestations. We conducted a descriptive cross-sectional study, which included prospectively from outpatients in the internal medicine department of university hospital center Aristide Le Dantec in Dakar, Senegal, with a diagnosis of rheumatoid arthritis without clinically evident cardiovascular disease. It focused on a sample of 73 patients of both sexes aged at least 18 years. Following clinical examination, we conducted laboratory tests (CRP, fibrinogen, ESR, rheumatoid factors: Latex and Waaler-Rose, anti-CCP, antinuclear factors and anti-ENA antibodies), ECG, echocardiography standard. Data were analyzed using a descriptive study of the different variables with the calculation of proportions for categorical variables, and the positional parameters and dispersion for quantitative variables. A total of 73 patients with rheumatoid arthritis without obvious cardiac events and meeting the criteria of definition of the ACR 1987 were included in the study. The mean age was 44.17±14.43 years with extremes of 18 and 75 years. The mean duration of RA was 5.93±4.78 years. The concept of family inflammatory arthritis was reported in 35.60% of cases and almost one in six patients had at least a factor of cardiovascular risk (16.96%). The abnormalities found in Doppler echocardiography were dominated by diastolic LV dysfunction (42.46%), increased left ventricular mass in 35.61%. Valvular leaks of variable grades were highlighted regarding all orifices but were rarely significant. The realization of echocardiography in patients with rheumatoid arthritis without clinically evident cardiovascular manifestations helps to highlight cardiovascular

  18. X-ray picture of the heart turn in echocardiographic diagnosis of rheumatic heart disease

    International Nuclear Information System (INIS)

    Grishkevich, A.M.; Goryanina, N.K.

    1986-01-01

    The paper is concerned with X-ray and echocardiographic investigation of the heart in 461 patients with mitral-tricuspidal disease. In 377 (82%) cases a turn of the heart along the longitudinal axis (counter clockwise) to the left and back was revealed. X-ray recognition of the heart turn made it possible to set an echocardiographic sensor to spot some of the cardiac cavities, interventricular septum and valvular apparatus. The correct setting of the echocardiographic sensor resulted in the determination of true sizes of each cardiac cavity, diagnosis of the nature of each valvular lesion and the recognition of such complications of rheumatic heart diseases as valvular calcinosis, left atrial thrombosis and disorder of myocardial contractility

  19. Tumor-mimicking large vegetation attached to the tricuspid valve without predisposing factors: A case report on CT and echocardiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jung Min; Choe, Yeon Hyeon; Hwang, Hye Won; Kim, Jung Sun; Kim, Wook Sung; Peck, Kyong Ran; Park, Sung Ji [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    We report the CT and echocardiographic findings of a tumor-mimicking large vegetation attached to the tricuspid valve (TV) of a 45-year-old man without predisposing factors. Echocardiography revealed a mobile homogeneous echogenic mass attached to the TV. Cardiac CT showed a 4.5 × 2.3 cm irregular low-density mass with scant enhancement in the right ventricle. Based on clinical findings of fever, positive blood culture results for Streptococcus viridans, and pathologic confirmation of the lesion, a diagnosis of infective endocarditis and vegetation was made.

  20. Tumor-mimicking large vegetation attached to the tricuspid valve without predisposing factors: A case report on CT and echocardiographic findings

    International Nuclear Information System (INIS)

    Bae, Jung Min; Choe, Yeon Hyeon; Hwang, Hye Won; Kim, Jung Sun; Kim, Wook Sung; Peck, Kyong Ran; Park, Sung Ji

    2015-01-01

    We report the CT and echocardiographic findings of a tumor-mimicking large vegetation attached to the tricuspid valve (TV) of a 45-year-old man without predisposing factors. Echocardiography revealed a mobile homogeneous echogenic mass attached to the TV. Cardiac CT showed a 4.5 × 2.3 cm irregular low-density mass with scant enhancement in the right ventricle. Based on clinical findings of fever, positive blood culture results for Streptococcus viridans, and pathologic confirmation of the lesion, a diagnosis of infective endocarditis and vegetation was made

  1. Echocardiographic Evaluation of Patent Ductus Arteriosus in Preterm Infants

    Directory of Open Access Journals (Sweden)

    Romaine Arlettaz

    2017-06-01

    Full Text Available Patent ductus arteriosus (PDA is part of the typical morbidity profile of the preterm infant, with a high incidence of 80–90% in extremely low birth weight infants born before 26 weeks of gestation. Whereas spontaneous closure of the ductus arteriosus (DA is likely in term infants, it is less so in preterm ones. PDA is associated with increased mortality and various comorbidities including cardiac failure, need for respiratory support, bronchopulmonary dysplasia, pulmonary or intracranial hemorrhage, and necrotizing enterocolitis; however, there is no proven causality between these morbidities and the presence of DA. Thus, the indication to close PDA remains highly controversial. This paper focuses on echocardiographic evaluation of PDA in the preterm infant and particularly on the echocardiographic signs of hemodynamic significance.

  2. Anomalous Aortic Origin of Coronary Arteries in the Young: Echocardiographic Evaluation With Surgical Correlation.

    Science.gov (United States)

    Lorber, Richard; Srivastava, Shubhika; Wilder, Travis J; McIntyre, Susan; DeCampli, William M; Williams, William G; Frommelt, Peter C; Parness, Ira A; Blackstone, Eugene H; Jacobs, Marshall L; Mertens, Luc; Brothers, Julie A; Herlong, J René

    2015-11-01

    This study sought to compare findings from institutional echocardiographic reports with imaging core laboratory (ICL) review of corresponding echocardiographic images and operative reports in 159 patients with anomalous aortic origin of a coronary artery (AAOCA). The study also sought to develop a "best practice" protocol for imaging and interpreting images in establishing the diagnosis of AAOCA. AAOCA is associated with sudden death in the young. Underlying anatomic risk factors that can cause ischemia-related events include coronary arterial ostial stenosis, intramural course of the proximal coronary within the aortic wall, interarterial course, and potential compression between the great arteries. Consistent protocols for diagnosing and evaluating these features are lacking, potentially precluding the ability to risk stratify patients based on evidence and plan surgical strategy. For a prescribed set of anatomic AAOCA features, percentages of missing data in institutional echocardiographic reports were calculated. For each feature, agreement among institutional echocardiographic reports, ICL review of images, and surgical reports was evaluated using the weighted kappa statistic. An echocardiographic imaging protocol was developed heuristically to reduce differences between institutional reports and ICL review. A total of 13%, 33%, and 62% of echocardiograms were missing images enabling diagnosis of intra-arterial course, proximal intramural course, and high ostial takeoff, respectively. There was poor agreement between institutional reports and ICL review for diagnosis of origin of coronary artery, interarterial course, intramural course, and acute angle takeoff (kappa = 0.74, 0.11, -0.03, 0.13, respectively). Surgical findings were also significantly different from those of reports, and to a lesser extent ICL reviews. The resulting protocol contains technical recommendations for imaging each of these features. Poor agreement between institutional reports and

  3. Myocardial Contrast Agents – Safety Considerations and Clinical Efficacy in Stress Echocardiography

    Directory of Open Access Journals (Sweden)

    Maier Anca

    2016-11-01

    Full Text Available Transthoracic echocardiographic examination is known to be a safe, non-invasive and reproducible method, used in every day clinical practice to obtain important information about cardiac structure and function. Unfortunately, a significant proportion of studies have highlighted the considerable technically difficultly in producing diagnostic images due to a poor acoustic window and more than 33% of patients undergoing stress echocardiography have suboptimal echocardiographic images. All these limitations have led to the use of contrast agents to improve the quality of standard ultrasound examination to provide a better delineation of left ventricle endocardial borders or to obtain information that cannot be achieved by using standard echocardiography, such as assessing myocardial microcirculation and therefore perfusion. This paper sought to review the clinical efficacy and safety of ultrasound contrast agents focusing on stress echocardiography.

  4. A stepwise composite echocardiographic score predicts severe pulmonary hypertension in patients with interstitial lung disease.

    Science.gov (United States)

    Bax, Simon; Bredy, Charlene; Kempny, Aleksander; Dimopoulos, Konstantinos; Devaraj, Anand; Walsh, Simon; Jacob, Joseph; Nair, Arjun; Kokosi, Maria; Keir, Gregory; Kouranos, Vasileios; George, Peter M; McCabe, Colm; Wilde, Michael; Wells, Athol; Li, Wei; Wort, Stephen John; Price, Laura C

    2018-04-01

    European Respiratory Society (ERS) guidelines recommend the assessment of patients with interstitial lung disease (ILD) and severe pulmonary hypertension (PH), as defined by a mean pulmonary artery pressure (mPAP) ≥35 mmHg at right heart catheterisation (RHC). We developed and validated a stepwise echocardiographic score to detect severe PH using the tricuspid regurgitant velocity and right atrial pressure (right ventricular systolic pressure (RVSP)) and additional echocardiographic signs. Consecutive ILD patients with suspected PH underwent RHC between 2005 and 2015. Receiver operating curve analysis tested the ability of components of the score to predict mPAP ≥35 mmHg, and a score devised using a stepwise approach. The score was tested in a contemporaneous validation cohort. The score used "additional PH signs" where RVSP was unavailable, using a bootstrapping technique. Within the derivation cohort (n=210), a score ≥7 predicted severe PH with 89% sensitivity, 71% specificity, positive predictive value 68% and negative predictive value 90%, with similar performance in the validation cohort (n=61) (area under the curve (AUC) 84.8% versus 83.1%, p=0.8). Although RVSP could be estimated in 92% of studies, reducing this to 60% maintained a fair accuracy (AUC 74.4%). This simple stepwise echocardiographic PH score can predict severe PH in patients with ILD.

  5. Echocardiographic anatomy of the mitral valve: a critical appraisal of 2-dimensional imaging protocols with a 3-dimensional perspective.

    Science.gov (United States)

    Mahmood, Feroze; Hess, Philip E; Matyal, Robina; Mackensen, G Burkhard; Wang, Angela; Qazi, Aisha; Panzica, Peter J; Lerner, Adam B; Maslow, Andrew

    2012-10-01

    To highlight the limitations of traditional 2-dimensional (2D) echocardiographic mitral valve (MV) examination methodologies, which do not account for patient-specific transesophageal echocardiographic (TEE) probe adjustments made during an actual clinical perioperative TEE examination. Institutional quality-improvement project. Tertiary care hospital. Attending anesthesiologists certified by the National Board of Echocardiography. Using the technique of multiplanar reformatting with 3-dimensional (3D) data, ambiguous 2D images of the MV were generated, which resembled standard midesophageal 2D views. Based on the 3D image, the MV scallops visualized in each 2D image were recognized exactly by the position of the scan plane. Twenty-three such 2D MV images were created in a presentation from the 3D datasets. Anesthesia staff members (n = 13) were invited to view the presentation based on the 2D images only and asked to identify the MV scallops. Their responses were scored as correct or incorrect based on the 3D image. The overall accuracy was 30.4% in identifying the MV scallops. The transcommissural view was identified correctly >90% of the time. The accuracy of the identification of A1, A3, P1, and P3 scallops was <50%. The accuracy of the identification of A2P2 scallops was ≥50%. In the absence of information on TEE probe adjustments performed to acquire a specific MV image, it is possible to misidentify the scallops. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Echocardiographic 3D-guided 2D planimetry in quantifying left-sided valvular heart disease.

    Science.gov (United States)

    Argulian, Edgar; Seetharam, Karthik

    2018-02-08

    Echocardiographic 3D-guided 2D planimetry can improve the accuracy of valvular disease assessment. Acquisition of 3D pyramidal dataset allows subsequent multiplanar reconstruction with accurate orthogonal plane alignment to obtain the correct borders of an anatomic orifice or flow area. Studies examining the 3D-guided 2D planimetry approach in left-sided valvular heart disease were identified and reviewed. The strongest evidence exists for estimating mitral valve area in patients with rheumatic mitral valve stenosis and vena contracta area in patients with mitral regurgitation (both primary and secondary). 3D-guided approach showed excellent feasibility and reproducibility in most studies, as well as time efficiency and good correlation with reference and comparator methods. Therefore, 3D-guided 2D planimetry can be used as an important clinical tool in quantifying left-sided valvular heart disease, especially mitral valve disorders. © 2018 Wiley Periodicals, Inc.

  7. Adult echocardiographic nomograms: overview, critical review and creation of a software for automatic, fast and easy calculation of normal values.

    Science.gov (United States)

    Cantinotti, Massimiliano; Giordano, Raffaele; Paterni, Marco; Saura, Daniel; Scalese, Marco; Franchi, Eliana; Assanta, Nadia; Koestenberg, Martin; Dulgheru, Raluca; Sugimoto, Tadafumi; Bernard, Anne; Caballero, Luis; Lancellotti, Patrizio

    2017-12-01

    There is a crescent interest on normal adult echocardiographic values and the introduction of new deformation imaging and 3D parameters pose the issue of normative data. A multitude of nomograms has been recently published, however data are often fragmentary, difficult to find, and their strengths/limitations have been never evaluated. (I) to provide a review of current echocardiographic nomograms; (II) to generate a tool for easy and fast access to these data. A literature search was conducted accessing the National Library of Medicine using the keywords: 2D/3D echocardiography, strain, left/right ventricle, atrial, mitral/tricuspid valve, aorta, reference values/nomograms/normal values. Adding the following keywords, the results were further refined: range/intervals, myocardial velocity, strain rate and speckle tracking. Forty one published studies were included. Our study reveals that for several of 2D/3D parameters sufficient normative data exist, however, a few limitations still persist. For some basic parameters (i.e., mitral/tricuspid/pulmonary valves, great vessels) and for 3D valves data are scarce. There is a lack of studies evaluating ethnic differences. Data have been generally expressed as mean values normalised for gender and age instead of computing models incorporating different variables (age/gender/body sizes) to calculate z scores. To summarize results a software ( Echocardio-Normal Values ) who automatically calculate range of normality for a broad range of echocardiographic measurements according to age/gender/weight/height, has been generated. We provide an up-to-date and critical review of strengths/limitation of current adult echocardiographic nomograms. Furthermore we generated a software for automatic, easy and fast access to multiple echocardiographic normative data.

  8. Morphologic-echocardiographic correlates of Ebstein's malformation.

    Science.gov (United States)

    Rusconi, P G; Zuberbuhler, J R; Anderson, R H; Rigby, M L

    1991-07-01

    The cross-sectional echocardiographic findings were analysed retrospectively in 26 patients with Ebstein's malformation in the light of studies of autopsied specimens from different patients showing this lesion. The salient anatomical feature in diagnosis is the finding of the hinge point of the septal and mural leaflets of the valve within the inlet component of the right ventricle rather than at the atrioventricular junction. The other important feature is the nature of the distal attachment of the leaflets, particularly the anterosuperior one, which can either be in focal or linear fashion. The hinge point of the septal leaflet was noted echocardiographically to be displaced in 19 patients but, significantly, the leaflet was absent in the other seven. Also significant was that the hinge point of the mural leaflet at the crux had been visualized in only 15 of the patients. The anterosuperior leaflet had a distal linear attachment in 20 of the patients, with the anteroseptal commissure becoming a keyhole in six of these through which blood passed to the functional right ventricle. The valve remained a competent structure, even though closing at the junction of atrialized and functional components of the right ventricle rather than at the atrioventricular junction. Cross-sectional echocardiography is the technique of choice with which to display the salient morphological features of Ebstein's malformation.

  9. Echocardiographic and radiographic findings in a cohort of healthy adult green iguanas (Iguana iguana).

    Science.gov (United States)

    Gustavsen, Kate A; Saunders, Ashley B; Young, Benjamin D; Winter, Randolph L; Hoppes, Sharman M

    2014-09-01

    To describe characteristics of echocardiography and cranial coelomic radiography in a cohort of iguanas. Twenty apparently healthy adult green iguanas (Iguana iguana) from a reptile sanctuary. Physical examination, radiography, two-dimensional and color Doppler echocardiography were performed to assess cardiac structures and function, and any related normal or abnormal findings were recorded. Echocardiographic examination was possible without sedation and allowed visualization of the great vessels, atria, and ventricle. Some structures could not be evaluated in a minority of the iguanas due to individual differences in bony conformation and imaging quality. Suspected abnormal echocardiographic findings in 3 iguanas included pericardial effusion (n = 1) and enlarged caudal vena cava and/or sinus venosus (n = 2). Objective measurements were repeatable as assessed by within-subject coefficient of variation, and reliable as assessed by intra-observer intraclass correlation coefficient. Left atrial and ventricular measurements were significantly correlated with body weight. Valve regurgitation was common, with atrioventricular valve regurgitation present in 53% (9/17) and aortic or pulmonic valve regurgitation in 71% (12/17) of otherwise normal iguanas. A heart murmur was not appreciated during examination of any of the iguanas. Heart size cannot be measured radiographically due to superimposition and silhouetting of other coelomic structures. Echocardiographic or radiographic findings consistent with mineralization of the great vessels were present in 76% of iguanas (13/17). Echocardiography in iguanas is well tolerated without sedation and allowed both subjective evaluation and structural measurements. Valve regurgitation and great vessel mineralization were commonly observed in this cohort of apparently healthy adult iguanas. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Echocardiographic right ventricle longitudinal contraction indices cannot predict ejection fraction in post-operative Fallot children.

    Science.gov (United States)

    Bonnemains, Laurent; Stos, Bertrand; Vaugrenard, Thibaud; Marie, Pierre-Yves; Odille, Freddy; Boudjemline, Younes

    2012-03-01

    To examine in a population of post-operative tetralogy of Fallot patients, the correlation between right ventricle (RV) ejection fractions (EF) computed from magnetic resonance imaging (MRI) and three echocardiographic indices of RV function: TAPSE, longitudinal strain and strain rate. Indeed, these patients present a pulmonary regurgitation which is responsible for progressive dilatation of the RV. An echocardiographic assessment of the RV function would be very useful in determining the timing of pulmonary revalvulation for Fallot patients. However, these indices are generally based on the ventricle contraction in the long axis direction which is impaired in this population and does not seem to correlate with the EF. Thirty-five post-operative tetralogy of Fallot patients and 20 patients with normal RVs were included. In both groups, RVEF, assessed by MRI, was compared with the three echocardiographic indices. Longitudinal strain and strain rates were computed both on the free wall and on the whole RV. No correlation was found between the echocardiographic indices and the MRI EF in our Fallot population. The accuracy of those indices as a diagnostic test of an altered RV was low with Younden's indices varying from -0.18 to 0.5 and areas under the Receiver Operating Characterictic (ROC) curves equal to 0.54 for tricuspid annulus plane systolic excursion, 0.59-0.62 for strain and 0.57-0.63 for strain rate. Three conventional echocardiographic indices based on RV longitudinal contraction failed to assess the EF in our population of post-operative tetralogy of Fallot patients.

  11. Echocardiographic evaluation of patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Hameed, S.; Malik, L.M.

    2007-01-01

    Cardiac disease occurs in various forms and is a common cause of death in systemic lupus erythematosus. The objective was to detect cardiac abnormalities by transthoracic echocardiography and determine their association in SLE patients. We conducted a transthoracic echocardiographic study in 48 inpatients with systemic lupus erythematosus. Clinical and serological evaluation to confirm the diagnosis of lupus was done in all patients. There were 44 women (91.6%) and 4 men with a mean age of 26 years. Anti ds DNA was positive in 34 patients (68.75%). Transthoracic echocardiography revealed abnormality in 28 patients (58.33%). Of these, 16 patients (57%) had pericardial involvement with variable amount of effusion. Twelve patients (43%) had some valvular involvement and some degree of myocardial systolic dysfunction was found in 12 patients (43%). Only 4 patients (14%) had all three abnormalities. Anti ds DNA was positive in 71% of patients with cardiac abnormalities. Cardiac involvement is common in patients with systemic lupus erythematosus. Serological abnormalities had an association with cardiac abnormalities, and were found to be more prevalent in young patients. (author)

  12. Correlation Between Body Mass Index and Echocardiographic Findings in Overweight Patients Compared to Normal-Weight Patients

    Directory of Open Access Journals (Sweden)

    Mohammad Salehi

    2017-08-01

    Full Text Available Background: Overweight is currently considered as the main risk factor for various chronic disorders, especially cardiovascular diseases. Unexpected hypertension is the first reaction of heart to overburden imposed by obesity or overweight. The purpose of the present study was to evaluate the correlation between body mass index (BMI and echocardiographic findings in overweight patients compared with normal-weight population. methods: This historical cohort study was conducted on 60 patients divided into two group of 30 based on their measured weights, group 1 with BMI of 20-25 kg/m2 as control and group 2 with 25clinical data along with the echocardiographic findings were recorded for all samples. Results: The mean age of control (41.06 ± 12.82 years and oversights (46.84 ± 12.61 years was not significantly different (P = 0.067. Systolic blood pressure (P = 0.003 and pulse rate (P = 0.028 were significantly higher in overweight group; ejection fraction (P = 0.036, end-systolic (P < 0.001 and end-diastolic (P < 0.001 left ventricular dimensions, and left ventricular mass index (P = 0.005 were significantly higher in control group. Conclusion: Overweighting due to anatomical remodeling can cause diastolic heart failure in left ventricle. According to the relatively poor prognosis of treatment features in patients with probable risk factors of heart failure such as diabetes, hypertension and ischemic heart disease (IHD, it is recommended to consider overweight as an effective prognostic factor.

  13. Automated segmentation and geometrical modeling of the tricuspid aortic valve in 3D echocardiographic images.

    Science.gov (United States)

    Pouch, Alison M; Wang, Hongzhi; Takabe, Manabu; Jackson, Benjamin M; Sehgal, Chandra M; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2013-01-01

    The aortic valve has been described with variable anatomical definitions, and the consistency of 2D manual measurement of valve dimensions in medical image data has been questionable. Given the importance of image-based morphological assessment in the diagnosis and surgical treatment of aortic valve disease, there is considerable need to develop a standardized framework for 3D valve segmentation and shape representation. Towards this goal, this work integrates template-based medial modeling and multi-atlas label fusion techniques to automatically delineate and quantitatively describe aortic leaflet geometry in 3D echocardiographic (3DE) images, a challenging task that has been explored only to a limited extent. The method makes use of expert knowledge of aortic leaflet image appearance, generates segmentations with consistent topology, and establishes a shape-based coordinate system on the aortic leaflets that enables standardized automated measurements. In this study, the algorithm is evaluated on 11 3DE images of normal human aortic leaflets acquired at mid systole. The clinical relevance of the method is its ability to capture leaflet geometry in 3DE image data with minimal user interaction while producing consistent measurements of 3D aortic leaflet geometry.

  14. Intravenous carbon dioxide as an echocardiographic contrast agent

    NARCIS (Netherlands)

    R.S. Meltzer (Richard); P.W.J.C. Serruys (Patrick); P.G. Hugenholtz (Paul); J.R.T.C. Roelandt (Jos)

    1981-01-01

    textabstractIntravenous carbon dioxide (CO2) was employed to cause echocardiographic contrast in 40 patients. One to 3 cc of medically pure CO2 were agitated with 5 to 8 cc of 5% dextrose in water and rapidly injected into an upper extremity vein. Contrast was obtained in all patients. In 33

  15. Changes in Mitral Annular Geometry after Aortic Valve Replacement: A Three-Dimensional Transesophageal Echocardiographic Study

    Science.gov (United States)

    Mahmood, Feroze; Warraich, Haider J.; Gorman, Joseph H.; Gorman, Robert C.; Chen, Tzong-Huei; Panzica, Peter; Maslow, Andrew; Khabbaz, Kamal

    2014-01-01

    Background and aim of the study Intraoperative real-time three-dimensional transesophageal echocardiography (RT-3D TEE) was used to examine the geometric changes that occur in the mitral annulus immediately after aortic valve replacement (AVR). Methods A total of 35 patients undergoing elective surgical AVR under cardiopulmonary bypass was enrolled in the study. Intraoperative RT-3D TEE was used prospectively to acquire volumetric echocardiographic datasets immediately before and after AVR. The 3D echocardiographic data were analyzed offline using TomTec® Mitral Valve Assessment software to assess changes in specific mitral annular geometric parameters. Results Datasets were successfully acquired and analyzed for all patients. A significant reduction was noted in the mitral annular area (-16.3%, p <0.001), circumference (-8.9% p <0.001) and the anteroposterior (-6.3%, p = 0.019) and anterolateral-posteromedial (-10.5%, p <0.001) diameters. A greater reduction was noted in the anterior annulus length compared to the posterior annulus length (10.5% versus 62%, p <0.05) after AVR. No significant change was seen in the non-planarity angle, coaptation depth, and closure line length. During the period of data acquisition before and after AVR, no significant change was noted in the central venous pressure or left ventricular end-diastolic diameter. Conclusion The mitral annulus undergoes significant geometric changes immediately after AVR Notably, a 16.3% reduction was observed in the mitral annular area. The anterior annulus underwent a greater reduction in length compared to the posterior annulus, which suggested the existence of a mechanical compression by the prosthetic valve. PMID:23409347

  16. Echocardiographic evaluation of the right heart.

    Science.gov (United States)

    Schneider, Matthias; Binder, Thomas

    2018-03-19

    Symptoms of right ventricular failure include dyspnea, a reduction in exercise capacity, and fluid retention. Right ventricular (dys)function strongly influences functional state and survival. The right ventricle is directly involved in a variety of diseases. A thorough analysis of right ventricular size and function, as well as estimation of pulmonary artery pressures is an important part of every echocardiographic examination. This review analyses the most commonly used parameters for quantification of right ventricular function. It gives a practical approach for estimation of right ventricular size and function, as well as pulmonary artery pressure.

  17. Echocardiographic diagnosis of rare pathological patterns of sinus of Valsalva aneurysm.

    Directory of Open Access Journals (Sweden)

    Yali Yang

    Full Text Available To evaluate the value and improve the diagnostic accuracy of echocardiography in the diagnosis of a sinus of Valsalva aneurysm (SVA with rare pathological patterns.Echocardiographic features and surgical findings from 270 Chinese patients with SVA treated in the last 18 years (1995-2013 at the Union Hospital were compared retrospectively; 22 of 270 cases had rare patterns.The patients with SVA, a rare origin, a rare extending position, or a rare course accounted for 3.4%, 7.4%, and 0.4% of the 270 cases, respectively. The three most common aneurysmal complications of the patients with rare patterns were severe aortic regurgitation (16, obstruction of the ventricular outflow tract or valvular orifice (3, and conduction disturbance (3. The origin, course, extending position and rupture status of the SVAs determined by echocardiography were entirely consistent with surgical findings in 81.8% of the 22 cases. With the exception of one failed diagnosis of an aneurysmal wall dissection and one misdiagnosis of a descending aortic dissection, the echocardiographic results of SVA complications and associated cardiovascular lesions were also confirmed.We could accurately diagnose SVAs with rare pathological patterns by echocardiographic identification of distinguishing features. However, for several conditions, we could not accurately identify the origin or course of the aneurysm or define its relationship to adjacent structures using conventional echocardiography alone. Therefore, we recommend combining conventional echocardiography with different imaging techniques, such as transesophageal echocardiography, three-dimensional echocardiography, computed tomography angiography, and aortic angiography.

  18. Invasive and noninvasive assessment of pulmonic regurgitation: clinical, angiographic, phonocardiographic, echocardiographic, and Doppler ultrasound correlations.

    Science.gov (United States)

    Chandraratna, P A; Wilson, D; Imaizumi, T; Ritter, W S; Aronow, W S

    1982-06-01

    Three patients with pulmonic regurgitation and no evidence of pulmonary hypertension were investigated. These patients had low pitched diastolic murmurs which increased on inspiration, evidence of connective tissue disease as manifested by lax joints and hyperextensible skin, and marked hilar dance which extended up to the peripheral vessels. Suprasternal echocardiography revealed dilatation and increased systolic expansion of the right pulmonary artery (RPA) (25% and 28%, respectively) in two patients; the third patient had a normal RPA dimension in diastole and a marked increase in diameter (88%) in systole. Thus, these three patients demonstrated hyperdistensibility of the RPA. The spectral signal from the pulsed doppler echocardiograph showed evidence of turbulent blood flow in diastole (wide dispersion of the dots) in the right ventricular outflow tract in all three patients. This pattern was indicative of pulmonic regurgitation. In summary, the combined use of echocardiography and Doppler ultrasound is useful in the evaluation of patients with pulmonic regurgitation.

  19. Clinical and Echocardiographic Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: Meta-Analysis and Meta-Regression.

    Science.gov (United States)

    Mohananey, Divyanshu; Jobanputra, Yash; Kumar, Arnav; Krishnaswamy, Amar; Mick, Stephanie; White, Jonathon M; Kapadia, Samir R

    2017-07-01

    Transcatheter aortic valve replacement has become the procedure of choice for inoperable, high-risk, and many intermediate-risk patients with aortic stenosis. Conduction abnormalities are a common finding after transcatheter aortic valve replacement and often result in permanent pacemaker (PPM) implantation. Data pertaining to the clinical impact of PPM implantation are controversial. We used meta-analysis techniques to summarize the effect of PPM implantation on clinical and echocardiographic outcomes after transcatheter aortic valve replacement. Data were summarized as Mantel-Haenszel relative risk (RR) and 95% confidence intervals (CIs) for dichotomous variables and as standardized mean difference and 95% CI for continuous variables We used the Higgins I 2 statistic to evaluate heterogeneity. We found that patients with and without PPM have similar all-cause mortality (RR, 0.85; 95% CI, 0.70-1.03), cardiovascular mortality (RR, 0.84; 95% CI, 0.59-1.18), myocardial infarction (RR, 0.47; 95% CI, 0.20-1.11), and stroke (RR, 1.26; 95% CI, 0.70-2.26) at 30 days. The groups were also comparable in all-cause mortality (RR, 1.03; 95% CI, 0.92-1.16), cardiovascular mortality (RR, 0.69; 95% CI, 0.39-1.24), myocardial infarction (RR, 0.58; 95% CI, 0.30-1.13), and stroke (RR, 0.70; 95% CI, 0.47-1.04) at 1 year. We observed that the improvement in left ventricular ejection fraction was significantly greater in the patients without PPM (standardized mean difference, 0.22; 95% CI, 0.12-0.32). PPM implantation is not associated with increased risk of all-cause mortality, cardiovascular mortality, stroke, or myocardial infarction both at short- and long-term follow-up. However, PPM is associated with impaired left ventricular ejection fraction recovery post-transcatheter aortic valve replacement. © 2017 American Heart Association, Inc.

  20. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  1. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    International Nuclear Information System (INIS)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L; De Boode, W P; Huisman, H J; Kapusta, L

    2009-01-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  2. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  3. Echocardiographic Risk Factors for Stroke and Outcomes in Patients With Atrial Fibrillation Anticoagulated With Apixaban or Warfarin.

    Science.gov (United States)

    Vinereanu, Dragos; Lopes, Renato D; Mulder, Hillary; Gersh, Bernard J; Hanna, Michael; de Barros E Silva, Pedro G M; Atar, Dan; Wallentin, Lars; Granger, Christopher B; Alexander, John H

    2017-12-01

    Few data exist on the long-term outcomes of patients with spontaneous echo contrast (SEC), left atrial/left atrial appendage (LA/LAA) thrombus, and complex aortic plaque (CAP), in patients with atrial fibrillation receiving oral anticoagulation. We explored the relationship between these 3 echocardiographic findings and clinical outcomes, and the comparative efficacy and safety of apixaban and warfarin for each finding. Patients from the ARISTOTLE trial (Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation) with SEC, LA/LAA thrombus, or CAP diagnosed by either transthoracic or transesophageal echocardiography were compared with patients with none of these findings on transesophageal echocardiography. A total of 1251 patients were included: 217 had SEC, 127 had LA/LAA thrombus, 241 had CAP, and 746 had none. The rates of stroke/systemic embolism were not significantly different among patients with and without these echocardiographic findings (hazard ratio, 0.96; 95% confidence interval, 0.25-3.60 for SEC; hazard ratio, 1.27; 95% confidence interval, 0.23-6.86 for LA/LAA thrombus; hazard ratio, 2.21; 95% confidence interval, 0.71-6.85 for CAP). Rates of ischemic stroke, myocardial infarction, cardiovascular death, and all-cause death were also not different between patients with and without these findings. For patients with either SEC or CAP, there was no evidence of a differential effect of apixaban over warfarin. For patients with LA/LAA thrombus, there was also no significant interaction, with the exception of all-cause death and any bleeding where there was a greater benefit of apixaban compared with warfarin among patients with no LA/LAA thrombus. In anticoagulated patients with atrial fibrillation and risk factors for stroke, echocardiographic findings do not seem to add to the risk of thromboembolic events. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00412984. © 2017 American Heart Association, Inc.

  4. Views of physicians in training on the ethical and legal issues in preliminary reporting of echocardiographic data.

    Science.gov (United States)

    McDonald, R W; Rice, M J; Marcella, C P; Reller, M D; Imus, R L

    1991-01-01

    Cardiac sonographers may be pressured by physicians into giving diagnostic interpretations of echocardiographic data. This study investigated the issue of preliminary reporting of echocardiographic data. A questionnaire was sent to 292 physicians; 85 physicians (29%) responded. Seventy-two physicians (87%) thought they had more than a minimal knowledge of echocardiography, 94% wanted a written or verbal preliminary report, and 84% thought that giving a preliminary report should be part of the cardiac sonographer's job. If abnormalities were found, 80% wanted the results before a cardiologist reviewed the study, and 56% would want a diagnostic rather than a descriptive report. Fifty-four physicians (64%) would pressure the cardiac sonographer into giving a preliminary echocardiographic report and would use this information to manage the patient. The majority of the physicians thought that it is legal for the cardiac sonographer to give a preliminary echocardiogram report. Eighty percent said that the cardiac sonographer would not be "practicing medicine without a license," and 82% that the sonographer would not be "aiding and abetting the unauthorized practice of medicine." This data would indicate that physicians at Oregon Health Sciences University want the cardiac sonographer to give preliminary echocardiographic results, even though the sonographer may be breaking state statutes.

  5. Feasibility, Reproducibility, and Agreement between Different Speckle Tracking Echocardiographic Techniques for the Assessment of Longitudinal Deformation

    Directory of Open Access Journals (Sweden)

    Sergio Buccheri

    2013-01-01

    Full Text Available Background. Left ventricular (LV longitudinal deformation can be assessed with new echocardiographic techniques like triplane echocardiography (3PE and four-dimensional echocardiography (4DE. We aimed to assess the feasibility, reproducibility, and agreement between these different speckle-tracking techniques for the assessment of longitudinal deformation. Methods. 101 consecutive subjects underwent echocardiographic examination. 2D cine loops from the apical views, a triplane view, and an LV 4D full volume were acquired in all subjects. LV longitudinal strain was obtained for each imaging modality. Results. 2DE analysis of LV strain was feasible in 90/101 subjects, 3PE strain in 89/101, and 4DE strain in 90/101. The mean value of 2DE and 3PE longitudinal strains was significantly higher with respect to 4DE. The relationship between 2DE and 3PE derived strains (r=0.782 was significantly higher (z=3.72, P<0.001 than that between 2DE and 4DE (r=0.429 and that between 3PE and 4DE (r=0.510; z=3.09, P=0.001. The mean bias between 2DE and 4DE strains was -6.61±7.31% while -6.42±6.81% between 3PE and 4DE strains; the bias between 2DE and 3PE strain was of 0.21±4.16%. Intraobserver and interobserver variabilities were acceptable among the techniques. Conclusions. Echocardiographic techniques for the assessment of longitudinal deformation are not interchangeable, and further studies are needed to assess specific reference values.

  6. Electrocardiographic intricacies clarified by echocardiography--should the electrocardiogram be interpreted echocardiographically?

    Science.gov (United States)

    Ker, James

    2012-07-12

    During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. The cardiovascular profile of soccer referees: an echocardiographic study

    Directory of Open Access Journals (Sweden)

    Toncelli L

    2008-02-01

    Full Text Available Abstract Background During a soccer game, the cardiovascular system is severely taxed The referees must be alert and their level of fitness must be such that fatigue will not impair their decision-making. Referee's peak overall performance is usually after 40 when the performance starts to decline. We evaluated the morphological and functional cardiac profile of professional soccer referees. Materials and methods We submitted to a clinical and echocardiographic exam a group of 120 professional soccer referees aged 25 – 45 years, including the first division of the Italian Championship, matched with 120 soccer players, including élite soccer players. Data were compared using an unpaired Student's t test. Statistical significance was with p Results Right ventricle dimensions (22.2 ± 3.8 vs 25.9 ± 2.4 mm and Left Ventricular Mass Index (LVMi (100.5 ± 45.2 vs 105.4 ± 17.3 were significantly greater in referees than in active soccer players. Left atrium dimensions (33.7 ± 8.9 vs 36.2 ± 3.1 mm, aortic root (29.7 ± 7.9 vs 32.1 ± 3 mm and LVMi (115.1 ± 16.7 vs 134.1 ± 19.9 g/m2 were significantly greater in élite soccer players than in first-division referees. Conclusion Our investigation shows that right ventricle is greater in referees than in soccer players. The differences (left atrium, aortic root and LVMi between first division referees and élite soccer players may derive from the different training workloads.

  8. Echocardiographic findings in infants with presumed congenital Zika syndrome: Retrospective case series study

    Science.gov (United States)

    Santos, Cleusa C.; Feitosa, Fabiana G.; Ribeiro, Maria C.; Menge, Paulo; Lira, Izabelle M.

    2017-01-01

    Objective To report the echocardiographic evaluation of 103 infants with presumed congenital Zika syndrome. Methods An observational retrospective study was performed at Instituto de Medicina Integral Prof. Fernando Figueira (IMIP), Recife, Brazil. 103 infants with presumed congenital Zika syndrome. All infants had microcephaly and head computed tomography findings compatible with congenital Zika syndrome. Zika IgM antibody was detected in cerebrospinal fluid samples of 23 infants. In 80 infants, the test was not performed because it was not available at that time. All infants had negative serology for HIV, syphilis, rubella, cytomegalovirus and toxoplasmosis. A complete transthoracic two-dimensional, M-mode, continuous wave and pulsed wave Doppler and color Doppler echocardiographic (PHILIPS HD11XE or HD15) examination was performed on all infants. Results 14/103 (13.5%) echocardiograms were compatible with congenital heart disease: 5 with an ostium secundum atrial septal defect, 8 had a hemodynamically insignificant small apical muscular ventricular septal defect and one infant with dyspnea had a large membranous ventricular septal defect. The echocardiograms considered normal included 45 infants with a persistent foramen ovale and 16 with a minimum patent ductus arteriosus. Conclusions Preliminarily this study suggests that congenital Zika syndrome may be associated with an increase prevalence of congenital heart disease. However the types of defects noted were septal defects, a proportion of which would not be hemodynamically significant. PMID:28426680

  9. Clinical and Echocardiographic Characteristics and Cardiovascular Outcomes According to Diabetes Status in Patients With Heart Failure and Preserved Ejection Fraction

    DEFF Research Database (Denmark)

    Kristensen, Søren L; Mogensen, Ulrik M; Jhund, Pardeep S

    2017-01-01

    in Heart Failure With Preserved Ejection Fraction) according to history of diabetes mellitus. Cox regression models were used to estimate hazard ratios for cardiovascular outcomes adjusted for known predictors, including age, sex, natriuretic peptides, and comorbidity. Echocardiographic data were available...... versus 29 kg/m2), worse Minnesota Living With Heart Failure score (48 versus 40), higher median N-terminal pro-B-type natriuretic peptide concentration (403 versus 320 pg/mL; all Pdifference in left ventricular ejection fraction. Patients with diabetes...

  10. Retrograde catheterisation vs. Doppler echocardiographic evaluation of aortic stenosis--a survey of contemporary UK practice.

    Science.gov (United States)

    Fazal, Iftikhar A; Alfakih, Khaled; Wilcox, Robert G; Walsh, John T

    2009-05-01

    Aortic stenosis (AS) is the most common indication for valve surgery. Recent data suggested an increased risk of cerebral emboli when the aortic valve is crossed to obtain 'pull-back' gradient. We conducted a large questionnaire based study to evaluate current practice in the assessment of aortic valve gradient amongst cardiologists and the preferences of cardiac surgeons in the UK. E-mail questionnaires were sent to 645 (72%) UK consultant cardiologists and to 198 (92%) UK consultant cardiac surgeons. 232 cardiologists and 52 cardiac surgeons responded. 53% of cardiologists routinely attempt to cross the valve in moderate AS while only 23% do so in severe AS. 38% of cardiologists in the age group '50+ years' cross the valve in severe AS compared to 13% in the age group '30-40 years'. Common reasons given for crossing a stenosed valve included 'to verify the echocardiographic gradient' (85%) and 'maintaining skill' (24%). 64% of cardiologists have changed their views on the necessity of crossing the valve in the last ten years. Although the majority appreciate the increased risk of crossing the valve only 18% of patients are consented differently if crossing the valve is planned. 26% of cardiac surgeons prefer the valve to be crossed to provide information on 'pull-back' gradient, 32% for LV function assessment and 14% to confirm MV competence. 92% would accept echocardiographic data alone if both the gradient and aortic valve area were available and considered correct. Our survey found that the practice of crossing the aortic valve has changed in the last 10 years and that younger consultant cardiologists are less likely to cross the aortic valve. Increasing confidence in echocardiographic data and potential complications of crossing the valve are implicated. 92% of cardiac surgeons do not require the valve to be crossed if the echo data is considered accurate.

  11. Clinic and echocardiographic characteristics of pericardial effusions in a university hospital, Medellín, Colombia Características clínicas y ecocardiográficas de los derrames pericárdicos en pacientes del Hospital Universitario San Vicente de Paúl

    Directory of Open Access Journals (Sweden)

    Carlos José Jaramillo G.

    2002-03-01

    Full Text Available Purpose: To determine the clinical and echocardiographic characteristics of pericardial effusions. Methods: Retrospective information was obtained from medical records of all patients who were diagnosed with echocardiographic pericardial effusions. Results: We studied 62 medical records of patients with echocardiographic pericardial effusions. We obtained medical records of 28 (45.2% patients with mild effusion, 19 (30.6% with moderate effusion and 15 (24.2% with severe effusion. Fourteen patients (22.6% showed inflammatory signs of pericarditis. Inflammatory signs had an Odds Ratio of 5.1. (CI 95% 1.28 to 23 wich was significant (p = 0.006. Uremia was the most common diagnosis in all patients (22.6% followed by metastatic tumors (14.5%, pyogenic pericarditis (11.3%, acute idiopathic pericarditis (11.3% and others. Conclusions: In almost all patients, etiology of pericardial effusion is the same of the underlying condition, but if the cause is unknown, the size of effusion, inflammatory signs and the presence of cardiac tamponade may help suggest etiology. Objetivos: determinar las características clínicas y ecocardiográficas de los derrames pericárdicos. Metodología: revisar retrospectivamente las historias clínicas de los pacientes con diagnóstico de derrame pericárdico hecho por ecocardiografía transtorácica entre febrero de 2000 y agosto de 2001. Resultados: se evaluaron las historias clínicas de 62 pacientes con diagnóstico de derrame pericárdico; 28 (45.2% presentaron derrames leves, 19 (30.6% derrames moderados y 15 (24.2% derrames severos; 21 (33.9% pacientes presentaron taponamiento cardíaco y el 50% de éstos tenían derrame severo. Se buscó la presencia de signos inflamatorios y se encontró que 14 (22.6% de los pacientes los presentaban. Además, estos pacientes tuvieron 5 veces más probabilidad de presentar taponamiento cardíaco (OR = 5.40. La principal causa de derrames pericárdicos fue la uremia (22.6%, seguida

  12. Prevalence of rheumatic valvular heart disease in Rwandan school children: echocardiographic evaluation using the World Heart Federation criteria

    Science.gov (United States)

    Mucumbitsi, J; Bulwer, B; Mutesa, L; Ndahindwa, MD, MSc; Semakula, M; Rusingiza, E; Arya, P; Breakey, S; Patton-Bolman, C; Kaplan, E L

    2017-01-01

    Summary Background: Rheumatic fever (RF) and rheumatic valvular heart disease (RHD) remain important medical, surgical and public health concerns in many parts of the world, especially in sub-Saharan Africa. However, there are no published data from Rwanda. We performed a RHD prevalence study in a randomly selected sample of Rwandan school children using the 2012 World Heart Federation (WHF) criteria. Methods: Echocardiographic assessment of 2 501 Rwandan school children from 10 schools in the Gasabo district near Kigali was carried out. Resulting data were evaluated by four experienced echocardiographers. Statistical analyses were carried out by statisticians. Results: RHD prevalence was 6.8/1 000 children examined (95% CI: 4.2/1 000–10.9/1 000). Seventeen met WHF criteria for RHD, 13 fulfilled criteria for ‘borderline’ RHD and four were ‘definite’ RHD. None of these 17 had been previously identified. Conclusion: These data indicate a significant burden of RHD in Rwanda and support a need for defined public health RF control programmes in children there. PMID:28252675

  13. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2012-02-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  14. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2010-11-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  15. Prognostic implications of left ventricular mass and geometry following myocardial infarction: the VALIANT (VALsartan In Acute myocardial iNfarcTion) Echocardiographic Study

    DEFF Research Database (Denmark)

    Verma, Anil; Meris, Alessandra; Skali, Hicham

    2008-01-01

    associated with RWT was independent of LVMi. CONCLUSIONS: Increased baseline LV mass and abnormal LV geometry portend an increased risk for morbidity and mortality following high-risk myocardial infarction. Concentric LV hypertrophy carries the greatest risk of adverse cardiovascular events including death...... cardiovascular events. METHODS: Quantitative echocardiographic analyses were performed at baseline in 603 patients from the VALIANT (VALsartan In Acute myocardial iNfarcTion) echocardiographic study. The left ventricular mass index (LVMi) and relative wall thickness (RWT) were calculated. Patients were...... classified into 4 mutually exclusive groups based on RWT and LVMi as follows: normal geometry (normal LVMi and normal RWT), concentric remodeling (normal LVMi and increased RWT), eccentric hypertrophy (increased LVMi and normal RWT), and concentric hypertrophy (increased LVMi and increased RWT). Cox...

  16. Right heart mechanics in untreated normotensive patients with prediabetes and type 2 diabetes mellitus: a two- and three-dimensional echocardiographic study.

    Science.gov (United States)

    Tadic, Marijana; Celic, Vera; Cuspidi, Cesare; Ilic, Sanja; Pencic, Biljana; Radojkovic, Jana; Ivanovic, Branislava; Stanisavljevic, Dejana; Kocabay, Gonenc; Marjanovic, Tamara

    2015-03-01

    The aim of this study was to determine right ventricular (RV) and right atrial (RA) deformation assessed by two-dimensional echocardiographic and three-dimensional echocardiographic (3DE) imaging in patients with prediabetes and type 2 diabetes mellitus. This cross-sectional study included 47 untreated normotensive subjects with prediabetes, 57 recently diagnosed normotensive patients with diabetes, and 54 healthy controls of similar sex and age distributions. All subjects underwent laboratory analyses and complete two-dimensional echocardiographic and 3DE examinations. Three-dimensional echocardiographic RV end-diastolic volume index gradually decreased from controls across patients with diabetes to those with diabetes (69 ± 10 vs 63 ± 8 vs 58 ± 8 mL/m(2), P < .001), whereas 3DE RV end-systolic volume index was higher in controls compared with patients with diabetes and those with diabetes (25 ± 4 vs 23 ± 4 vs 22 ± 4 mL/m(2), P < .001). However, there was no difference in 3DE RV ejection fraction among the three groups (63 ± 4% vs 62 ± 4% vs 61 ± 5%, P = .063). RV and RA global strain and systolic and early diastolic strain rates were decreased in patients with prediabetes and in those with diabetes compared with controls, whereas RV and RA late diastolic strain rates were increased in these patients. Multivariate regression analysis showed that RV global strain was associated with glycated hemoglobin, independent of left ventricular parameters. RV and RA myocardial deformation and function obtained by 3DE and two-dimensional echocardiographic strain, even in normal ranges, were decreased in patients with prediabetes and in those with diabetes compared with controls. The long-term parameter of glucose control was correlated with the right heart mechanics. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  17. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    Science.gov (United States)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  18. Estimating Right Atrial Pressure Using Ultrasounds: An Old Issue Revisited With New Methods.

    Science.gov (United States)

    De Vecchis, Renato; Baldi, Cesare; Giandomenico, Giuseppe; Di Maio, Marco; Giasi, Anna; Cioppa, Carmela

    2016-08-01

    Knowledge of the right atrial pressure (RAP) values is critical to ascertain the existence of a state of hemodynamic congestion, irrespective of the possible presence of signs and symptoms of clinical congestion and cardiac overload that can be lacking in some conditions of concealed or clinically misleading cardiac decompensation. In addition, a more reliable estimate of RAP would make it possible to determine more accurately also the systolic pulmonary arterial pressure with the only echocardiographic methods. The authors briefly illustrate some of the criteria that have been implemented to obtain a non-invasive RAP estimate, some of which have been approved by current guidelines and others are still awaiting official endorsement from the Scientific Societies of Cardiology. There is a representation of the sometimes opposing views of researchers who have studied the problem, and the prospects for development of new diagnostic criteria are outlined, in particular those derived from the matched use of two- and three-dimensional echocardiographic parameters.

  19. Prognostic implications of fasting plasma glucose in subjects with echocardiographic abnormalities

    DEFF Research Database (Denmark)

    Pareek, Manan; Vaduganathan, Muthiah; Bhatt, Deepak L

    2017-01-01

    AIMS: To examine whether baseline fasting plasma glucose (FPG) modifies the prognostic role of left ventricular (LV) mass, geometric pattern, and diastolic function, for prediction of cardiovascular morbidity and mortality. METHODS: Population-based cohort study comprising of 1047 men and 456 women...... proportional-hazards regression with interaction analysis was used to evaluate the risk associated with FPG and LV structure and function. RESULTS: Median age was 67years, and 31% had impaired fasting glucose, 31% diabetes, 17% LV hypertrophy, and 40% diastolic dysfunction. During a median follow-up duration.......001), and with the association between diastolic dysfunction and event risk (P=0.02), including grade 2 or 3 dysfunction (P=0.04). CONCLUSIONS: Echocardiographic abnormalities were more strongly associated with an adverse prognosis among subjects with impaired fasting glucose or diabetes....

  20. Echocardiographic study of the cardiac state in systemic scleroderma

    International Nuclear Information System (INIS)

    Kotel'nikova, G.P.; Guseva, N.G.

    1986-01-01

    Echocardiographic investigation in 65 patients with systemic scleroderma showed that the left ventricular syes and indices of central hemodynamics were frequently lowered in them; an increase in sizes was observed mainly in the patients with stage 2-3 of disease. Echocardiography made it possible to specify the nature of cardiac pathology and brought to light some additional features of the involvement of different heart membranes in systemic scleroderma

  1. Echocardiographic predictors of exercise capacity and mortality in chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Schoos, Mikkel Malby; Dalsgaard, Morten; Kjærgaard, Jesper

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) reduces exercise capacity, but lung function parameters do not fully explain functional class and lung-heart interaction could be the explanation. We evaluated echocardiographic predictors of mortality and six minutes walking distance (6MWD), a marker...... for quality of life and mortality in COPD....

  2. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  3. Echocardiographic Parameters and Survival in Chagas Heart Disease with Severe Systolic Dysfunction

    International Nuclear Information System (INIS)

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-01-01

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m 2 were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction

  4. Echocardiographic Parameters and Survival in Chagas Heart Disease with Severe Systolic Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Rassi, Daniela do Carmo, E-mail: dani.rassi@hotmail.com [Faculdade de Medicina e Hospital das Clínicas da Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil); Vieira, Marcelo Luiz Campos [Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo (USP), São Paulo, SP (Brazil); Arruda, Ana Lúcia Martins [Instituto de Radiologia da Faculdade de Medicina da Universidade de São Paulo (USP), São Paulo, SP (Brazil); Hotta, Viviane Tiemi [Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo (USP), São Paulo, SP (Brazil); Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador [Faculdade de Medicina e Hospital das Clínicas da Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil)

    2014-03-15

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m{sup 2} were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction.

  5. Transesophageal echocardiography simulation is an effective tool in teaching psychomotor skills to novice echocardiographers.

    Science.gov (United States)

    Sohmer, Benjamin; Hudson, Christopher; Hudson, Jordan; Posner, Glenn D; Naik, Viren

    2014-03-01

    Performance of transesophageal echocardiography (TEE) requires the psychomotor ability to obtain interpretable echocardiographic images. The purpose of this study was to determine the effectiveness of a simulation-based curriculum in which a TEE simulator is used to teach the psychomotor skills to novice echocardiographers and to compare instructor-guided with self-directed online delivery of the curriculum. After institutional review board approval, subjects inexperienced in TEE completed an online review of TEE material prior to a baseline pre-test of TEE psychomotor skills using the simulator. Subjects were randomized to two groups. The first group received an instructor-guided lesson of TEE psychomotor skills with the simulator. The second group received a self-directed slide presentation of TEE psychomotor skills with the simulator. Both lessons delivered identical information. Following their respective training sessions, all subjects performed a post-test of their TEE psychomotor skills using the simulator. Two assessors rated the TEE performances using a validated scoring system for acquisition of images. Pre-test TEE simulator scores were similar between the two instruction groups (9.0 vs 5.0; P = 0.28). The scores in both groups improved significantly following training, regardless of the method of instruction (P psychomotor skills. There was no difference in improvement between the different modalities of instruction. Further research will examine the need for a faculty resource for a curriculum in which a simulator is used as an adjunct.

  6. Echocardiographic evaluation of heart in chronic obstructive pulmonary disease patient and its co-relation with the severity of disease

    Directory of Open Access Journals (Sweden)

    N K Gupta

    2011-01-01

    Full Text Available Background: Chronic obstructive pulmonary disease (COPD has considerable effects on cardiac functions, including those of the right ventricle, left ventricle, and pulmonary blood vessels. Most of the increased mortality associated with COPD is due to cardiac involvement. Echocardiography provides a rapid, noninvasive, portable, and accurate method to evaluate the cardiac changes. Aims: To assess the cardiac changes secondary to COPD by echocardiography and to find out the correlation between echocardiographic findings and severity of COPD, if there is any. Materials and Methods: A total 40 of patients of COPD were selected and staged by pulmonary function test (PFT and evaluated by echocardiography. Results: On echocardiographic evaluation of COPD, 50% cases had normal echocardiographic parameters. Measurable tricuspid regurgitation (TR was observed in 27/40 cases (67.5%. Pulmonary hypertension (PH, which is defined as systolic pulmonary arterial pressure (sPAP > 30 mmHg was observed in 17/27 (63% cases in which prevalence of mild, moderate, and severe PH were 10/17 (58.82%, 4/17 (23.53%, and 3/17 (17.65%, respectively. The frequencies of PH in mild, moderate, severe, and very severe COPD were 16.67%, 54.55%, 60.00%, and 83.33%, respectively. Right atrial pressure was 10 mmHg in 82.5% cases and 15 mmHg in 17.5% cases. Cor pulmonale was observed in 7/17 (41.17% cases; 7.50% cases had left ventricle (LV systolic dysfunction and 47.5% cases had evidence of LV diastolic dysfunction defined as A ≥ E (peak mitral flow velocity of the early rapid filling wave (E, peak velocity of the late filling wave caused by atrial contraction (A on mitral valve tracing. Left ventricle hypertrophy was found in 22.5% cases. Conclusion : Prevalence of PH has a linear relationship with severity of COPD and severe PH is almost associated with cor pulmonale. Echocardiography helps in early detection of cardiac complications in COPD cases giving time for early

  7. NT-proBNP, echocardiographic abnormalities and subclinical coronary artery disease in high risk type 2 diabetic patients

    DEFF Research Database (Denmark)

    Reinhard, Henrik; Hansen, Peter R; Wiinberg, Niels

    2012-01-01

    -NT-proBNP and the putative residual abnormalities in such patients are not well described. This study examined echocardiographic measurements of LV hypertrophy, atrial dilatation and LV dysfunction and their relation to P-NT-proBNP levels or subclinical coronary artery disease (CAD) in type 2 diabetic patients......Intensive multifactorial treatment aimed at prevention of cardiovascular (CV) disease may reduce left ventricular (LV) echocardiographic abnormalities in diabetic subjects. Plasma N-terminal (NT)-proBNP predicts CV mortality in diabetic patients but the association between P...

  8. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study.

    Science.gov (United States)

    Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio

    2018-02-23

    To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

  9. [Teaching methods for clinical settings: a literature review].

    Science.gov (United States)

    Brugnolli, Anna; Benaglio, Carla

    2017-01-01

    . Teaching Methods for clinical settings: a review. The teaching process during internship requires several methods to promote the acquisition of more complex technical skills such as relational, decisional and planning abilities. To describe effective teaching methods to promote the learning of relational, decisional and planning skills. A literature review of the teaching methods that have proven most effective, most appreciated by students, and most frequently used in Italian nursing schools. Clinical teaching is a central element to transform clinical experiences during internship in professional competences. The students are gradually brought to become more independent, because they are offered opportunities to practice in real contexts, to receive feedback, to have positive role models, to become more autonomous: all elements that facilitate and potentiate learning. Clinical teaching should be based on a variety of methods. The students value a gradual progression both in clinical experiences and teaching strategies from more supervised methods to methods more oriented towards reflecting on clinical practice and self-directed learning.

  10. Echocardiographic findings predict in-hospital and 1-year mortality in left-sided native valve Staphylococcus aureus endocarditis

    DEFF Research Database (Denmark)

    Lauridsen, Trine K.; Park, Lawrence; Tong, Steven Y C

    2015-01-01

    BACKGROUND: Staphylococcus aureus left-sided native valve infective endocarditis (LNVIE) has higher complication and mortality rates compared with endocarditis from other pathogens. Whether echocardiographic variables can predict prognosis in S aureus LNVIE is unknown. METHODS AND RESULTS......: Consecutive patients with LNVIE, enrolled between January 2000 and September 2006, in the International Collaboration on Endocarditis were identified. Subjects without S aureus IE were matched to those with S aureus IE by the propensity of having S aureus. Survival differences were determined using log...

  11. Echocardiographic Assessment of Pulmonary Arterial Hypertension for Pediatricians and Neonatologists

    Directory of Open Access Journals (Sweden)

    Gregory James Skinner

    2017-09-01

    Full Text Available There is a growing awareness of the role that increased pulmonary vascular resistance (PVR plays in many pathologies; therefore, assessment of pulmonary artery pressure (PAP is an increasingly requested investigation in the critical care environment. This article will go through the basic concepts regarding PAP and PVR, then will go on to outline the various echocardiographic parameters which are used to assess them. Finally, an outline of how to undertake this assessment will be presented.

  12. The predictive value of transthoracic echocardiographic variables for sinus rhythm maintenance after electrical cardioversion of atrial fibrillation. Results from the CAPRAF study, a prospective, randomized, placebo-controlled study.

    Science.gov (United States)

    Grundvold, Irene; Tveit, Arnljot; Smith, Pål; Seljeflot, Ingebjørg; Abdelnoor, Michael; Arnesen, Harald

    2008-01-01

    The recurrence rate of atrial fibrillation after electrical cardioversion is disappointingly high. The aim of the present study was to prospectively investigate if standard echocardiographic variables at the day of cardioversion could predict sinus rhythm maintenance. Transthoracic echocardiographic examination was performed within 4 h after cardioversion for all the patients in the CAPRAF (Candesartan in the Prevention of Relapsing Atrial Fibrillation) study. Cardioversion was successful for 137 patients not given specific antiarrhythmic therapy, and only 41 (30%) maintained sinus rhythm at 6-month follow-up. There were significant (p = 0.05) lower transmitral A wave velocities in the group with relapsing atrial fibrillation compared with the group with sinus rhythm at 6-month follow-up. All patients with the lowest A wave velocities had an early recurrence of atrial fibrillation. There were no differences between the groups regarding atrial dimensions or left ventricular function. The use of the angiotensin II receptor antagonist candesartan had no influence on the echocardiographic variables, nor on the recurrence rate of atrial fibrillation after cardioversion. Transthoracic echocardiographic examination performed a short time after electrical cardioversion of atrial fibrillation showed that only A wave peak velocities were significantly predictive of sinus rhythm maintenance 6 months after the procedure. (c) 2008 S. Karger AG, Basel.

  13. Echocardiographic characteristics in Fontan patients before the onset of protein-losing enteropathy or plastic bronchitis.

    Science.gov (United States)

    Du Bois, Florian; Stiller, Brigitte; Borth-Bruhns, Thomas; Unseld, Bettina; Kubicki, Rouven; Hoehn, René; Reineker, Katja; Grohmann, Jochen; Fleck, Thilo

    2018-01-01

    It was this study's objective to evaluate the echocardiographic characteristics and flow patterns in abdominal arteries of Fontan patients before the onset of protein-losing enteropathy (PLE) or plastic bronchitis (PB). In this retrospective cohort investigation, we examined 170 Fontan patients from 32 different centers who had undergone echocardiographic and Doppler ultrasound examinations between June 2006 and May 2013. Follow-up questionnaires were completed by 105 patients a median of 5.3 (1.5-8.5) years later to evaluate whether one of the complications had occurred since the examinations. A total of 91 patients never developed PLE or PB ("non-PLE/PB"); they were compared to 14 affected patients. Eight of the 14 patients had already been diagnosed with "present PLE/PB" when examined. Six "future PLE/PB" patients developed those complications later on and were identified on follow-up. The "future PLE/PB" patients presented significantly slower diastolic flow velocities in the celiac artery (0.1 (0.1-0.5) m/s vs 0.3 (0.1-1.0) m/s (P = .04) and in the superior mesenteric artery (0.0 (0.0-0.2) m/s vs 0.2 (0.0-0.6) m/s, P = .02) than the "non-PLE/PB" group. Median resistance indices in the celiac artery were significantly higher (0.9 (0.8-0.9) m/s vs 0.8 (0.6-0.9) m/s, (P = .01)) even before the onset of PLE or PB. An elevated flow resistance in the celiac artery may prevail in Fontan patients before the clinical manifestation of PLE or PB. © 2017 Wiley Periodicals, Inc.

  14. The Value of Quality Improvement Process in the Detection and Correction of Common Errors in Echocardiographic Hemodynamic Parameters in a Busy Echocardiography Laboratory.

    Science.gov (United States)

    Fanari, Zaher; Choudhry, Usman I; Reddy, Vivek K; Eze-Nliam, Chete; Hammami, Sumaya; Kolm, Paul; Weintraub, William S; Marshall, Erik S

    2015-12-01

    Accurate assessment of cardiac structures, ventricular function, and hemodynamics is essential for any echocardiographic laboratory. Quality improvement (QI) processes described by the American Society of Echocardiography (ASE) and the Intersocietal Commission (IAC) should be instrumental in reaching this goal. All patients undergoing transthoracic echocardiogram (TTE) followed by cardiac catheterization within 24 hours at Christiana Care Health System in 2011 and 2012 were identified, with 126 and 133 cases, respectively. Hemodynamic parameters of diastolic function and pulmonary artery systolic pressure (PASP) on TTE correlated poorly with catheterization in 2011. An educational process was developed and implemented at quarterly QI meetings based on ASE and IAC recommendations to target frequently encountered errors and provide methods for improved performance. The hemodynamic parameters were then reexamined in 2012 postintervention. Following the QI process, there was significant improvement in the correlation between invasive and echocardiographic hemodynamic measurements in both systolic and diastolic function, and PASP. This reflected in significant better correlations between echo and cath LVEF [R = 0.88, ICC = 0.87 vs. R = 0.85, ICC = 0.85; P process, as recommended by ASE and IAC, can allow for identification as well as rectification of quality issues in a large regional academic medical center hospital. © 2015, Wiley Periodicals, Inc.

  15. Clinical Features and Echocardiographic Findings in Children with Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Cristina Blesneac

    2013-12-01

    Full Text Available Background: Hypertrophic cardiomyopathy, one of the most common inherited cardiomyopathies, is a heterogeneous disease resulting from sarcomeric protein mutations, with an incidence in the adult population of 1:500. Current information on the epidemiology and outcomes of this disease in children is limited. Methods: Thirty-four children diagnosed with hypertrophic cardiomyopathy in the Pediatric Cardiology Department from Tîrgu Mureș were evaluated concerning familial and personal history, clinical, paraclinical and therapeutic aspects. Hypertrophic cardiomyopathy was defined by the presence of a hypertrophied, non-dilated ventricle, in the absence of a cardiac or systemic disease that could produce ventricular hypertrophy. Results: The youngest diagnosed child was a neonate, a total of 10 patients being diagnosed until 1 year of age. In 6 cases a positive familial history was found. Noonan syndrome was found in 2 cases. Only 21 patients were symptomatic, the predominant symptoms being shortness of breath on exertion with exercise limitations. Left ventricular outflow tract obstruction was present in 21 cases (61.7%. Twenty-four patients were on β-blocking therapy, while 4 patients underwent septal myectomy. Conclusions: Hypertrophic cardiomyopathy is a heterogeneous disorder in terms of evolution, age of onset, type and extent of hypertrophy, and the risk of sudden death. It can affect children of any age. There is a need for a complex evaluation, including familial and personal anamnesis, clinical examination, electrocardiogram and echocardiography of all patients. It is highly important to develop screening strategies, including genetic testing, for an early diagnosis, especially in asymptomatic patients with a positive familial background

  16. Echocardiographic Screening of Rheumatic Heart Disease in American Samoa.

    Science.gov (United States)

    Huang, Jennifer H; Favazza, Michael; Legg, Arthur; Holmes, Kathryn W; Armsby, Laurie; Eliapo-Unutoa, Ipuniuesea; Pilgrim, Thomas; Madriago, Erin J

    2018-01-01

    While rheumatic heart disease (RHD) is a treatable disease nearly eradicated in the United States, it remains the most common form of acquired heart disease in the developing world. This study used echocardiographic screening to determine the prevalence of RHD in children in American Samoa. Screening took place at a subset of local schools. Private schools were recruited and public schools underwent cluster randomization based on population density. We collected survey information and performed a limited physical examination and echocardiogram using the World Heart Federation protocol for consented school children aged 5-18 years old. Of 2200 students from two private high schools and two public primary schools, 1058 subjects consented and were screened. Overall, 133 (12.9%) children were identified as having either definite (3.5%) or borderline (9.4%) RHD. Of the patients with definitive RHD, 28 subjects had abnormal mitral valves with pathologic regurgitation, three mitral stenosis, three abnormal aortic valves with pathologic regurgitation, and seven borderline mitral and aortic valve disease. Of the subjects with borderline disease, 77 had pathologic mitral regurgitation, 12 pathologic aortic regurgitation, and 7 at least two features of mitral valve disease without pathologic regurgitation or stenosis. Rheumatic heart disease remains a major cause of morbidity and mortality worldwide. The prevalence of RHD in American Samoa (12.9%) is to date the highest reported in the world literature. Echocardiographic screening of school children is feasible, while reliance on murmur and Jones criteria is not helpful in identifying children with RHD.

  17. A meta-analysis for the echocardiographic assessment of right ventricular structure and function in ARVC: a Study by the Research and Audit Committee of the British Society of Echocardiography

    Directory of Open Access Journals (Sweden)

    Mohammad Qasem

    2016-10-01

    Full Text Available Introduction: Arrhythmogenic right ventricular cardiomyopathy ARVC is an inherited pathology that can increase the risk of sudden death. Current task force criteria for echocardiographic diagnosis do not include new, regional assessment tools which may be relevant in a phenotypically diverse disease. We adopted a systematic review and meta-analysis approach to highlight echocardiographic indices that differentiated ARVC patients and healthy controls. Methods: Data was extracted and analysed from prospective trials that employed a case–control design meeting strict inclusion and exclusion as well as a priori quality criteria. Structural indices included proximal RV outflow tract (RVOT1 and RV diastolic area (RVDarea. Functional indices included RV fractional area change (RVFAC, tricuspid annular systolic excursion (TAPSE, peak systolic and early diastolic myocardial velocities (S′ and E′, respectively and myocardial strain. Results: Patients with ARVC had larger RVOT1 (mean ± s.d.; 34 vs 28 mm, P < 0.001 and RVDarea (23 vs 18 cm2, P < 0.001 compared with healthy controls. ARVC patients also had lower RVFAC (38 vs 46%, P < 0.001, TAPSE (17 vs 23 mm, P < 0.001, S′ (9 vs 12 cm/s, P < 0.001, E′ (9 vs 13 cm/s, P < 0.001 and myocardial strain (−17 vs −30%, P < 0.001. Conclusion: The data from this meta-analysis support current task force criteria for the diagnosis of ARVC. In addition, other RV measures that reflect the complex geometry and function in ARVC clearly differentiated between ARVC and healthy controls and may provide additional diagnostic and management value. We recommend that future working groups consider this data when proposing new/revised criteria for the echocardiographic diagnosis of ARVC.

  18. Power of resting echocardiographic measurements to classify pulmonary hypertension patients according to European society of cardiology exercise testing risk stratification cut-offs.

    Science.gov (United States)

    Rehman, Michaela B; Garcia, Rodrigue; Christiaens, Luc; Larrieu-Ardilouze, Elisa; Howard, Luke S; Nihoyannopoulos, Petros

    2018-04-15

    Right ventricular function is the major determinant of morbidity and mortality in pulmonary arterial hypertension (PAH). The ESC risk assessment strategy for PAH is based on clinical status, exercise testing, NTproBNP, imaging and haemodynamics but does not include right ventricular function. Our aims were to test the power of resting echocardiographic measurements to classify PAH patients according to ESC exercise testing risk stratification cut-offs and to determine if the classification power of echocardiographic parameters varied in chronic thrombo-embolic pulmonary hypertension (CTEPH). We prospectively and consecutively recruited 46 PAH patients and 42 CTEPH patients referred for cardio-pulmonary exercise testing and comprehensive transthoracic echocardiography. Exercise testing parameters analyzed were peak oxygen consumption, percentage of predicted maximal oxygen consumption and the slope of ventilation against carbon dioxide production. Receiver operator characteristic curves were used to determine the optimal diagnostic cut-off values of echocardiographic parameters for classifying the patients in intermediate or high risk category according to exercise testing. Measurements of right ventricular systolic function were the best for classifying in PAH (area under the curve 0.815 to 0.935). Measurements of right ventricular pressure overload (0.810 to 0.909) were optimal for classifying according to exercise testing in CTEPH. Measurements of left ventricular function were of no use in either group. Measurements of right ventricular systolic function can classify according to exercise testing risk stratification cut-offs in PAH. However, this is not the case in CTEPH where pressure overload, rather than right ventricular function seems to be linked to exercise performance. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Gudejko, Michael D; Gebhardt, Brian R; Zahedi, Farhad; Jain, Ankit; Breeze, Janis L; Lawrence, Matthew R; Shernan, Stanton K; Kapur, Navin K; Kiernan, Michael S; Couper, Greg; Cobey, Frederick C

    2018-06-05

    Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of

  20. Echocardiography and risk prediction in advanced heart failure: incremental value over clinical markers.

    Science.gov (United States)

    Agha, Syed A; Kalogeropoulos, Andreas P; Shih, Jeffrey; Georgiopoulou, Vasiliki V; Giamouzis, Grigorios; Anarado, Perry; Mangalat, Deepa; Hussain, Imad; Book, Wendy; Laskar, Sonjoy; Smith, Andrew L; Martin, Randolph; Butler, Javed

    2009-09-01

    Incremental value of echocardiography over clinical parameters for outcome prediction in advanced heart failure (HF) is not well established. We evaluated 223 patients with advanced HF receiving optimal therapy (91.9% angiotensin-converting enzyme inhibitor/angiotensin receptor blocker, 92.8% beta-blockers, 71.8% biventricular pacemaker, and/or defibrillator use). The Seattle Heart Failure Model (SHFM) was used as the reference clinical risk prediction scheme. The incremental value of echocardiographic parameters for event prediction (death or urgent heart transplantation) was measured by the improvement in fit and discrimination achieved by addition of standard echocardiographic parameters to the SHFM. After a median follow-up of 2.4 years, there were 38 (17.0%) events (35 deaths; 3 urgent transplants). The SHFM had likelihood ratio (LR) chi(2) 32.0 and C statistic 0.756 for event prediction. Left ventricular end-systolic volume, stroke volume, and severe tricuspid regurgitation were independent echocardiographic predictors of events. The addition of these parameters to SHFM improved LR chi(2) to 72.0 and C statistic to 0.866 (P advanced HF.

  1. Congenital Heart Diseases in the Newborns of Diabetic Mothers: an Echocardiographic Study

    Directory of Open Access Journals (Sweden)

    S Rahimpour

    2011-10-01

    Full Text Available Introduction: Despite the discovery of insulin and current improvement in diabetics care, congenital malformations in diabetics are still more frequent than in the general population. The aim of this study was to identify congenital heart dieases (CHD in the newborns of diabetic mothers (IDMS. Methods: In our prospective study, color doppler echocardiography was performed in 75 consecutive full- term newborns of diabetic mothers by GE Vivid3 echocardiographic device. Newborns were classified into two subgroups according to the type of the mothers’ diabetes: pre-gestational and gestational. They were also those were classified into three subgroups according to their birth weight: appropriate, large and small for gestational age. Data analysis was made by Fisher exact test and Chi-Square test. Results: Forty nine (65% and thirty six (35% of subjects were infants of gestational (IGDM and pre-gestational diabetic mothers (IPDM, respectively. Fifty five Newborns (73% were apropriate, fourteen (19% were large and six (8% were small for gestational age. The most common echocardiographic findings included: patent ductus arteriosus (PDA: 54.7%, hypertrophic cardiomyopathy (HCMP: 24%, ventricular septal defect (VSD: 4%, atrial septal defect (ASD: 2.7%, transposition of great arteries (TGA: 1.3% and coarctation of the Aorta (COA: 1.3%. Overall incidence of congenital heart diseases was 9.3 after exclusion of PDA and HCMP cases. The incidence of congenital heart diseases was higher in macrosomic than nonmacrosomic infants of diabetic mothers (P<0.001. Congenital heart diseases were more common in infants of pre-gestational than gestational diabetic mothers (P=0.004. Conclusion: Our results showed that diabetic mothers are at increased risk of giving birth to a newborn with congenital heart disease, and transthoracic echocardiography is recommended for all infants of diabetic mothers.

  2. Fractional order integration and fuzzy logic based filter for denoising of echocardiographic image.

    Science.gov (United States)

    Saadia, Ayesha; Rashdi, Adnan

    2016-12-01

    Ultrasound is widely used for imaging due to its cost effectiveness and safety feature. However, ultrasound images are inherently corrupted with speckle noise which severely affects the quality of these images and create difficulty for physicians in diagnosis. To get maximum benefit from ultrasound imaging, image denoising is an essential requirement. To perform image denoising, a two stage methodology using fuzzy weighted mean and fractional integration filter has been proposed in this research work. In stage-1, image pixels are processed by applying a 3 × 3 window around each pixel and fuzzy logic is used to assign weights to the pixels in each window, replacing central pixel of the window with weighted mean of all neighboring pixels present in the same window. Noise suppression is achieved by assigning weights to the pixels while preserving edges and other important features of an image. In stage-2, the resultant image is further improved by fractional order integration filter. Effectiveness of the proposed methodology has been analyzed for standard test images artificially corrupted with speckle noise and real ultrasound B-mode images. Results of the proposed technique have been compared with different state-of-the-art techniques including Lsmv, Wiener, Geometric filter, Bilateral, Non-local means, Wavelet, Perona et al., Total variation (TV), Global Adaptive Fractional Integral Algorithm (GAFIA) and Improved Fractional Order Differential (IFD) model. Comparison has been done on quantitative and qualitative basis. For quantitative analysis different metrics like Peak Signal to Noise Ratio (PSNR), Speckle Suppression Index (SSI), Structural Similarity (SSIM), Edge Preservation Index (β) and Correlation Coefficient (ρ) have been used. Simulations have been done using Matlab. Simulation results of artificially corrupted standard test images and two real Echocardiographic images reveal that the proposed method outperforms existing image denoising techniques

  3. Allometric scaling of echocardiographic measurements in healthy Spanish foals with different body weight.

    Science.gov (United States)

    Rovira, S; Muñoz, A; Rodilla, V

    2009-04-01

    Scaling in biology is usually allometric, and therefore, the size of the heart may be expressed as a power function of body weight (BW). The present research analyses the echocardiographic measurements in 68 healthy Spanish foals weighed between 70 and 347kg in order to determine the correct scaling exponent for the allometric equation. The echocardiographic parameters measured were: left ventricular internal dimensions (LVID), free wall thickness (LVFWT), interventricular septum thickness (IVST) at systole (s) and diastole (d), EPSS (distance between the point E of the mitral valve and the interventricular septum), and aorta diameters at the level of the aortic valve (AOD), base of valve leaflets (ABS), sinus of Valsalva (ASV) and sino-tubular junction (AJT). Indices of left ventricular performance were calculated. It was found that LVIDd, IVSTs, AOD, and ASV have a relationship to BW raised to 0.300-0.368 power, whereas left ventricular end-diastolic volume and stroke volume scaled to BW raised to 0.731-0.712 power. With these data, appropriate values can be calculated for normal Spanish foals.

  4. Urine albumin/creatinine ratio and echocardiographic left ventricular structure and function in hypertensive patients with electrocardiographic left ventricular hypertrophy: The LIFE Study

    DEFF Research Database (Denmark)

    Wachtell, K.; Palmieri, V.; Olsen, M.H.

    2002-01-01

    in a large hypertensive population. Methods The urine albumin/creatinine ratio (UACR) and echocardiographic measures of LV structure and function were obtained in 833 patients with stage I to III hypertension and LV hypertrophy determined by electrocardiogram (ECG) (Cornell voltage-duration or Sokolow...... geometry and high LV mass are associated with high UACR independent of age, systolic blood pressure, diabetes, and race, suggesting parallel cardiac and microvascular damage....

  5. Spectrum of heart diseases in children: an echocardiographic study of 1,666 subjects in a pediatric hospital, Yaounde, Cameroon.

    Science.gov (United States)

    Chelo, David; Nguefack, Félicitée; Menanga, Alain P; Ngo Um, Suzanne; Gody, Jean C; Tatah, Sandra A; Koki Ndombo, Paul O

    2016-02-01

    Children's health programs in Sub-Saharan Africa have always been oriented primarily to infectious diseases and malnutrition. We are witnessing in the early 21(st) century an epidemiological transition marked by the decline of old diseases and the identification of new diseases including heart disease. Therefore, it is necessary to describe the spectrum of these diseases in order to better prepare health workers to these new challenges. We conducted a cross-sectional study focused on heart disease diagnosed by echocardiography in children seen from January 2006 to December 2014 in a pediatric hospital of Yaounde. We collected socio-demographic data and the types of heart disease from registers, patients files as well as the electronic database of echocardiographic records. A total of 2,235 patients underwent echocardiographic examination during the study period including 1,666 subjects with heart disease. Congenital cardiopathies were found in 1,230 (73.8%) patients and acquired abnormalities in 429 (25.8%). Seven children (0.4%) had a combination of both types. Congenital heart defects (CHD) were dominated by ventricular septal defect (VSD). Acquired heart disease was mostly rheumatic valvulopathies. Dyspnea on exertion was the most frequent presenting complaint (87.6%). Discovery of a heart murmur was the principal clinical finding on physical examination (81.4%). The median age was 9 months for congenital heart disease and 132 months for acquired heart disease. As infectious diseases recede and the diagnostic facilities are improving, pediatric heart diseases occupy a more important position in the spectrum of pediatric diseases in our context. However, the ability to evoke the diagnosis remains unsatisfactory by the majority of health personnel and therefore needs to be improved. Apart from congenital heart diseases, the impact of acquired heart diseases, rheumatic valvulopathy being the highest ranking, is remarkable in pediatrics. Awareness of health

  6. Diagnostic Value of Selected Echocardiographic Variables to Identify Pulmonary Hypertension in Dogs with Myxomatous Mitral Valve Disease.

    Science.gov (United States)

    Tidholm, A; Höglund, K; Häggström, J; Ljungvall, I

    2015-01-01

    Pulmonary hypertension (PH) is commonly associated with myxomatous mitral valve disease (MMVD). Because dogs with PH present without measureable tricuspid regurgitation (TR), it would be useful to investigate echocardiographic variables that can identify PH. To investigate associations between estimated systolic TR pressure gradient (TRPG) and dog characteristics and selected echocardiographic variables. 156 privately owned dogs. Prospective observational study comparing the estimations of TRPG with dog characteristics and selected echocardiographic variables in dogs with MMVD and measureable TR. Tricuspid regurgitation pressure gradient was significantly (P modeled as linear variables LA/Ao (P modeled as second order polynomial variables: AT/DT (P = .0039) and LVIDDn (P value for the final model was 0.45 and receiver operating characteristic curve analysis suggested the model's performance to predict PH, defined as 36, 45, and 55 mmHg as fair (area under the curve [AUC] = 0.80), good (AUC = 0.86), and excellent (AUC = 0.92), respectively. In dogs with MMVD, the presence of PH might be suspected with the combination of decreased PA AT/DT, increased RVIDDn and LA/Ao, and a small or great LVIDDn. Copyright © 2015 The Authors Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Dynamic 3D echocardiography in virtual reality.

    NARCIS (Netherlands)

    A.E. van den Bosch (Annemien); A.H.J. Koning (Anton); F.J. Meijboom (Folkert); J.S. Vletter-McGhie (Jackie); M.L. Simoons (Maarten); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2005-01-01

    textabstractBACKGROUND: This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. METHODS: Three-dimensional echocardiographic

  8. Influence of Angiotensin-Converting-Enzyme Gene Polymorphism on Echocardiographic Data of Patients with Ischemic Heart Failure.

    Science.gov (United States)

    Duque, Gustavo Salgado; Silva, Dayse Aparecida da; Albuquerque, Felipe Neves de; Schneider, Roberta Siuffo; Gimenez, Alinne; Pozzan, Roberto; Rocha, Ricardo Mourilhe; Albuquerque, Denilson Campos de

    2016-11-01

    Association between angiotensin-converting-enzyme (ACE) gene polymorphisms and different clinical and echocardiographic outcomes has been described in patients with heart failure (HF) and coronary artery disease. Studying the genetic profile of the local population with both diseases is necessary to assess the occurrence of that association. To assess the frequency of ACE gene polymorphisms in patients with ischemic HF in a Rio de Janeiro population, as well as its association with echocardiographic findings. Genetic assessment of I/D ACE polymorphism in association with clinical, laboratory and echocardiographic analysis of 99 patients. The allele frequency was: 53 I alleles, and 145 D alleles. Genotype frequencies were: 49.5% DD; 47.48% DI; 3.02% II. Drug treatment was optimized: 98% on beta-blockers, and 84.8% on ACE inhibitors or angiotensin-receptor blocker. Echocardiographic findings: difference between left ventricular diastolic diameters (ΔLVDD) during follow-up: 2.98±8.94 (DD) vs. 0.68±8.12 (DI) vs. -11.0±7.00 (II), p=0.018; worsening during follow-up of the LV systolic diameter (LVSD): 65.3% DD vs. 19.0% DI vs. 0.0% II, p=0.01; of the LV diastolic diameter (LVDD): 65.3% DD vs. 46.8% DI vs. 0.0% II, p=0.03; and of the LV ejection fraction (LVEF): 67.3% DD vs. 40.4% DI vs. 33.3% II, p=0.024. Correlated with D allele: ΔLVEF, ΔLVSD, ΔLVDD. More DD genotype patients had worsening of the LVEF, LVSD and LVDD, followed by DI genotype patients, while II genotype patients had the best outcome. The same pattern was observed for ΔLVDD. Associação entre polimorfismos genéticos da enzima conversora da angiotensina (ECA) e diferentes evoluções clínicas e ecocardiográficas foi descrita em pacientes com insuficiência cardíaca (IC) e coronariopatia. O estudo do perfil genético da população local com as duas doenças torna-se necessário para verificar a ocorrência dessa associação. Avaliar a frequência dos polimorfismos genéticos da ECA em

  9. Echocardiographic parameters and survival in Chagas heart disease with severe systolic dysfunction.

    Science.gov (United States)

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-03-01

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p 70.71 mL/m2 were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction.

  10. Echocardiographic identification of ventricular septal rupture caused by acute stent thrombosis.

    Science.gov (United States)

    Garg, Scot; Bourantas, Christos V; Thackray, Simon; Alamgir, Mohamed F

    2010-05-01

    Coronary stenting is an increasingly common procedure. Complications are rare. However, when they do occur, they often require urgent invasive treatment. Investigations that are critical for establishing a diagnosis as well as such guide treatment as a detailed assessment of myocardial morphology and function using transthoracic echocardiography may be overlooked in the haste to treat the patient. We present a case report of subacute drug-eluting stent thrombosis in which a meticulous echocardiographic examination allowed the identification of a ventricular septal rupture, which ultimately modified treatment.

  11. Echocardiographic and Hemodynamic Predictors of Survival in Precapillary Pulmonary Hypertension: Seven-Year Follow-Up.

    Science.gov (United States)

    Grapsa, Julia; Pereira Nunes, Maria Carmo; Tan, Timothy C; Cabrita, Ines Zimbarra; Coulter, Taryn; Smith, Benjamin C F; Dawson, David; Gibbs, J Simon R; Nihoyannopoulos, Petros

    2015-06-01

    In this study, we looked at the prognostic value of echocardiographic and hemodynamic measures in a large cohort of patients with precapillary pulmonary hypertension before and after initiation of treatment. Data were collected prospectively in a cohort of consecutive patients with precapillary pulmonary hypertension referred between 2002 and 2011. A range of clinical and echocardiographic variables were collected and stored on a database to assess predictors of survival. Invasive hemodynamic data including pulmonary artery pressure, pulmonary vascular resistance, capillary wedge pressure, and cardiac index were also obtained at baseline in all patients. Outcome was defined as mortality because of cardiovascular-related death. The study cohort comprised 777 patients (514 women) with precapillary pulmonary hypertension. A total of 195 (25%) died. In multivariable analysis, moderate or severe tricuspid regurgitation (hazard ratio [HR], 26.537; 95% confidence interval, 11.536-61.044; P<0.001), right ventricular myocardial performance index (HR, 3.421; 95% confidence interval, 1.777-6.584; P<0.001), and the presence of pericardial effusion (HR, 1.38; 95% confidence interval, 1.023-1.862; P=0.035) were independent predictors of mortality. High pulmonary vascular resistance and right atrial pressure by invasive hemodynamic measurements were independent predictors of mortality (HR, 1.084; 95% confidence interval, 1.041-1.130, and 1.079, respectively; 95% confidence interval, 1.049-1.111; P<0.001 for both), whereas patients with a higher cardiac index had better survival overall (HR, 0.384; 95% confidence interval, 0.307-0.481; P<0.001). Right ventricular dysfunction, moderate-severe tricuspid regurgitation, low cardiac index, and raised right atrial pressure were associated with poor survival for both pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertensive disease patients. The severity of tricuspid regurgitation, myocardial performance index

  12. Comparison of echocardiographic findings in patients with nonfunctioning adrenal incidentalomas

    Directory of Open Access Journals (Sweden)

    Narin Nasıroglu Imga

    2017-06-01

    Full Text Available Adrenal incidentalomas (AIs are usually discovered incidentally after imaging unrelated to adrenal glands. We aimed to evaluate standard risk factors for systemic atherosclerosis and echocardiographic changes in patients with nonfunctioning AIs and compare them with normal subjects. We evaluated 70 patients diagnosed with AIs and 51 healthy controls. Mean levels were determined for HbA1c, LDL, uric acid, fasting plasma insulin, HOMA, and neutrophil-to-lymphocyte ratio (NLR, and these values were found to be significantly higher in the patients than the controls. The mean left atrial diameter, interventricular septum thickness, posterior wall thickness, left ventricular mass, E-wave deceleration time, isovolumetric relaxation time, and the median ratio of the early transmittal flow velocity to the early diastolic tissue velocity (E/Em were higher in patients with AIs compared to controls. The mitral annular early diastolic velocity was lower in patients with AIs. The mean aortic diastolic diameter, stiffness index (SI, and aortic strain were higher, and aortic distensibility was lower in the patients. The mean right ventricular diameter, right atrial major-axis diameter, and right atrial minor-axis diameter were statistically higher in the patient group than the controls. A negative correlation was found between the NLR and aortic strain and aortic distensibility, while a positive correction was found between the NLR and SI. We found altered left ventricular (LV and right ventricular (RV echocardiographic findings in patients with AIs without known cardiovascular disease. Aortic stiffness was also increased. These changes may be related to an increase in cardiovascular risk factors in AI patients.

  13. The clover technique for the treatment of complex tricuspid valve insufficiency: midterm clinical and echocardiographic results in 66 patients.

    Science.gov (United States)

    Lapenna, Elisabetta; De Bonis, Michele; Verzini, Alessandro; La Canna, Giovanni; Ferrara, David; Calabrese, Maria Chiara; Taramasso, Maurizio; Alfieri, Ottavio

    2010-06-01

    This study assesses the results of the 'clover technique' (suturing together the middle point of the free edges of the tricuspid leaflets) for the treatment of tricuspid regurgitation (TR) due to severe prolapse or tethering. From 2001, 66 patients with severe TR due to prolapsing or tethered leaflets underwent 'clover repair'. Annuloplasty was associated in 64 patients (97%). The aetiology of TR was degenerative in 52 cases (79%), post-traumatic in eight (12%) and secondary to dilated cardiomyopathy (DCM) in six (9%). The main mechanism of TR was prolapse/flail of one leaflet in 15 patients (23%), of two leaflets in 31 (47%) and of all three leaflets in 14 (21%). The remaining six patients (9%) presented with severe leaflets' tethering. Four deaths (6%) occurred during hospitalisation and one patient died 3.6 years after surgery. Survival was 91 + or - 4.1% at 5 years. Follow-up of the 62 hospital survivors was 100% complete (mean length 3.5 + or - 1.6 years, range 13 months-7.1 years). At the last echocardiogram, no or mild TR was detected in 55 (88.7%) patients, moderate (2+/4+) in six (9.6%) and severe (4+/4+) in one patient (1.6%). Mean tricuspid valve area and gradient were 4.3 + or - 0.6 cm(2) and 2.8 + or -1.4 mmHg. In six patients, stress echocardiography was performed and no signs of tricuspid stenosis were detected. At the multivariable analysis, the degree of TR at hospital discharge was identified as the only predictor of TR > or = 2+ at follow-up. Midterm clinical and echocardiographic results confirm the role of the 'clover technique' in the surgical treatment of TR due to lesions, which are unlikely to be effectively treatable by annuloplasty alone. Copyright 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  14. Doença crônica da valva mitral em cães: avaliação clínica funcional e mensuração ecocardiográfica da valva mitral Chronic mitral valvular disease in dogs: assessment of functional clinical stage and echocardiographic measurement of the mitral valve

    Directory of Open Access Journals (Sweden)

    R.A.L. Muzzi

    2009-04-01

    Full Text Available Foram descritos os achados do exame físico em cães com degeneração mixomatosa crônica da valva mitral e mensurado o comprimento e a espessura das cúspides da valva mitral pelo exame ecocardiográfico. Utilizaram-se 81 cães de diferentes raças de pequeno a médio porte, com idade de 11,12± 2,51 anos e peso de 6,24kg± 3,19, dos quais 20 eram clinicamente normais (grupo-controle e 61 apresentavam evidências clínicas de cardiopatia. Os animais foram distribuídos em três classes distintas segundo a insuficiência cardíaca congestiva (grupos I, II e III, de acordo com os dados do histórico e dos sinais clínicos apresentados. Ao exame ecocardiográfico, avaliaram-se as medidas das cúspides da valva mitral, que não apresentaram diferença entre os cães do grupo I e II, embora estivessem anormais se comparadas às dos cães do grupo-controle. Nos animais do grupo III, as medidas das valvas avaliadas foram maiores que as dos cães dos grupos I e II. Foram observados nódulos com formato arredondado e, nos cães do grupo III, as cúspides estavam bastante alongadas e espessadas.Physical and echocardiographic aspects were studied in dogs with chronic mitral valvular disease. The length and thickness of the mitral valve leaflets were echocardiographically measured. Eighty-one dogs of small-medium breeds (mean of 6.24kg± 3.19, older than six years (11.12± 2.51 years were used. Twenty were clinically normal dogs (control group and 61 presented myxomatous degeneration of the mitral valve. The diseased dogs were categorized into three classes of congestive heart failure (I, II, and III groups according to the information on clinical manifestations. On the echocardiographic exam, the measurements of the mitral valve leaflets were evaluated and no diferences between dogs of groups I and II were found, though they were abnormal if compared with control group animals. Group III dogs presented measurements higher than those of animals of groups

  15. [Comparison of echocardiographic findings in AVS patients with and without high IgG, IgM, IgA titers against Chlamydia pneumoniae during 12 months' observation of AVS natural course].

    Science.gov (United States)

    Swierszcz, Jolanta; Dubiel, Jacek S; Krzysiek, Józef; Sztefko, Krystyna; Galicka-Latała, Danuta; Roman, Pfitzner; Podolec, Piotr; Wodniecki, Jan

    2011-01-01

    Comparison of echocardiographic findings in AVS patients with and without high IgG, IgM, IgA titers against Chlamydia pneumoniae during 12 months' observation of AVS natural course. 60 AVS patients who did not agree for operational treatment were divided into group A (30 patients with high IgG titer) group B (30 patients with low IgG titer), group C (22 patients with high IgA titer) group D (38 patients with low IgA titer), group E (7 patients with high IgM titer), group F (53 patients with low IgA titer) Antibodies titers and echocardiographic scans were carried out every 12 months. There were more (p AVS deterioration in group A compared to group B. Group A patients had lower left ventricle posteriori wall systolic diameter compared to group B. There were no differences in echocardiographic parameters between group C and D. Mean ejection fraction was lower and mean right atrium diameter was higher in group E compared to group F. The results may suggest link between Chlamydia pneumoniae and deterioration of AVS.

  16. Prognostic usefulness of repeated echocardiographic evaluation after acute myocardial infarction. TRACE Study Group. TRAndolapril Cardiac Evaluation

    DEFF Research Database (Denmark)

    Korup, E; Køber, L; Torp-Pedersen, C

    1999-01-01

    The prognostic value of repeated echocardiographic measurement of left ventricular function after acute myocardial infarction was evaluated. We found that repeated measurements of wall motion index in survivors of acute myocardial infarction, with no reinfarction, provide important prognostic...

  17. Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique.

    Science.gov (United States)

    Hausleiter, Jörg; Braun, Daniel; Orban, Mathias; Latib, Azeem; Lurz, Philipp; Boekstegers, Peter; von Bardeleben, Ralph Stephan; Kowalski, Marek; Hahn, Rebecca T; Maisano, Francesco; Hagl, Christian; Massberg, Steffen; Nabauer, Michael

    2018-04-24

    Severe tricuspid regurgitation (TR) has long been neglected despite its well known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though the device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and variability of tricuspid valve anatomy, echocardiographic visibility of the valve leaflets, and device steering to the tricuspid valve. Furthermore, it remains to be clarified which patients are suitable for a percutaneous tricuspid repair and which features predict a successful procedure. On the basis of the available experience, we describe criteria for patient selection including morphological valve features, a standardized process for echocardiographic screening, and a strategy for clip placement. These criteria will help to achieve standardization of valve assessment and the procedural approach, and to further develop interventional tricuspid valve repair using either currently available devices or dedicated tricuspid edge-to-edge repair devices in the future. In summary, this manuscript will provide guidance for patient selection and echocardiographic screening when considering edge-to-edge repair for severe TR.

  18. The reliability of echocardiographic left ventricular wall motion index to identify high-risk patients for multicenter studies

    DEFF Research Database (Denmark)

    Gislason, Gunnar H; Gadsbøll, Niels; Quinones, Miguel A

    2006-01-01

    that were screened for inclusion into the DIAMOND-CHF and DIAMOND-MI trials were reevaluated by an external expert echocardiographer. WMI was calculated using the 16-segment LV model. RESULTS: The external echocardiographer systematically found lower values of WMI than the core laboratory. The average...... difference in WMI was 0.18 (SD: 0.33) in the DIAMOND-CHF trial and 0.09 (SD: 0.33) in the DIAMOND-MI trial. The difference in WMI exceeded 0.33 in 34% of the patients in both trials. The cutoff value for inclusion into the DIAMOND trials was WMI ... overall agreement for identifying patients with severe impairment of LV function. This not only underscores the value of LV-WMI as a useful tool for selecting high-risk patients to be included in multicenter studies but also serves to warn against the use of rigid cutoff values for WMI in the treatment...

  19. Atrial Fibrillation in Hypertrophic Cardiomyopathy: Prevalence, Clinical Correlations, and Mortality in a Large High‐Risk Population

    Science.gov (United States)

    Siontis, Konstantinos C.; Geske, Jeffrey B.; Ong, Kevin; Nishimura, Rick A.; Ommen, Steve R.; Gersh, Bernard J.

    2014-01-01

    Background Atrial fibrillation (AF) is a common sequela of hypertrophic cardiomyopathy (HCM), but evidence on its prevalence, risk factors, and effect on mortality is sparse. We sought to evaluate the prevalence of AF, identify clinical and echocardiographic correlates, and assess its effect on mortality in a large high‐risk HCM population. Methods and Results We identified HCM patients who underwent evaluation at our institution from 1975 to 2012. AF was defined by known history (either chronic or paroxysmal), electrocardiogram, or Holter monitoring at index visit. We examined clinical and echocardiographic variables in association with AF. The effect of AF on overall and cause‐specific mortality was evaluated with multivariate Cox proportional hazards models. Of 3673 patients with HCM, 650 (18%) had AF. Patients with AF were older and more symptomatic (P<0.001). AF was less common among patients with obstructive HCM phenotype and was associated with larger left atria, higher E/e’ ratios, and worse cardiopulmonary exercise tolerance (all P values<0.001). During median (interquartile range) follow‐up of 4.1 (0.2 to 10) years, 1069 (29%) patients died. Patients with AF had worse survival compared to those without AF (P<0.001). In multivariate analysis adjusted for established risk factors of mortality in HCM, the hazard ratio (95% confidence interval) for the effect of AF on overall mortality was 1.48 (1.27 to 1.71). AF did not have an effect on sudden or nonsudden cardiac death. Conclusions In this large referral HCM population, approximately 1 in 5 patients had AF. AF was a strong predictor of mortality, even after adjustment for established risk factors. PMID:24965028

  20. Echocardiographic findings in infants with presumed congenital Zika syndrome: Retrospective case series study.

    Directory of Open Access Journals (Sweden)

    Danielle Di Cavalcanti

    Full Text Available To report the echocardiographic evaluation of 103 infants with presumed congenital Zika syndrome.An observational retrospective study was performed at Instituto de Medicina Integral Prof. Fernando Figueira (IMIP, Recife, Brazil. 103 infants with presumed congenital Zika syndrome. All infants had microcephaly and head computed tomography findings compatible with congenital Zika syndrome. Zika IgM antibody was detected in cerebrospinal fluid samples of 23 infants. In 80 infants, the test was not performed because it was not available at that time. All infants had negative serology for HIV, syphilis, rubella, cytomegalovirus and toxoplasmosis. A complete transthoracic two-dimensional, M-mode, continuous wave and pulsed wave Doppler and color Doppler echocardiographic (PHILIPS HD11XE or HD15 examination was performed on all infants.14/103 (13.5% echocardiograms were compatible with congenital heart disease: 5 with an ostium secundum atrial septal defect, 8 had a hemodynamically insignificant small apical muscular ventricular septal defect and one infant with dyspnea had a large membranous ventricular septal defect. The echocardiograms considered normal included 45 infants with a persistent foramen ovale and 16 with a minimum patent ductus arteriosus.Preliminarily this study suggests that congenital Zika syndrome may be associated with an increase prevalence of congenital heart disease. However the types of defects noted were septal defects, a proportion of which would not be hemodynamically significant.

  1. Echocardiograph alterations in asthma patients

    Directory of Open Access Journals (Sweden)

    André Luís Mancini

    2008-05-01

    Full Text Available Introduction: Asthma is a chronic inflammatory disease which has increased during the last 20 years, putting a strain on medical resources, particularly severe forms of the disease. Treatment in such cases is inhaled corticosteroids and beta agonist drugs that can produce a range of side effects. The aim of this study is to identify echocardiograph abnormalities and correlate them with severity of disease. Methodology: Eight-seven outpatients were selected at the asthma unit of the Gaffree Guinle University Hospital (HUGG. Each patient underwent spirometry, electrocardiogram (ECG and echocardiogram (ECO during the trial within a month maximum. Echocardiograph abnormalities found related to degree of asthma. Statistical analysis was made by nonparametric tests. Results: We found significant differences (p ≤ 0.05 for age, disease duration and haemoglobin saturation (SaO2 between the moderate and severe groups. In the sample a high prevalence of tricuspid insufficiency (41.4% was identified. Conclusions: ECO identified a series of abnormalities that were not always dependent on severity of disease. ECO can identify pulmonary hypertension through calculation of mean pressure of the pulmonary artery. Resumo: Introdução: A asma é uma doença inflamatória crónica cuja prevalência vem aumentando nos últimos 20 anos. Demanda grande utilização de recursos, principalmente no grupo grave. Neste, há consumo crónico de corticóides inalatórios e de β2-agonistas, que podem produzir uma série de problemas. O objectivo deste trabalho é o de rastrear as alterações electro e ecocardiográficas e relacioná-las ao grau da asma. Metodologia: Selecionámos 87 doentes do ambulatório de asma do HUGG, que, por rotina, possuem uma espirografia, um eletrocardiograma (ECG e um ecocardiograma (ECO feitos com um intervalo máximo de um mês. As alterações ecocardiográficas encontradas

  2. Echocardiographic profile of rheumatic heart disease at a tertiary cardiac centre

    International Nuclear Information System (INIS)

    Aurakzai, H.A.; Hameed, S.; Shahbaz, A.; Gohar, S.; Qureshi, M.; Khan, H.; Sami, W.; Azhar, M.; Khan, J.S.

    2009-01-01

    Rheumatic Heart Disease (RHD) continues to be a major public health problem in developing countries like Pakistan. Objective of this cross sectional-analytical study was to analyze the severity of valvular lesions on echocardiography in patients pre-diagnosed with RHD. Methods: The trans thoracic echocardiographic records of RHD patients from 2004 to 2008 were retrospectively reviewed for type and degree of valvular involvement according to AHA/ACC guidelines. Results: A total of 13,414 patients [7,219 Males (53.8%), 6,195 Females (46.2%)]ranging from 11 to 90 years with a mean age of 42.33 +- 18.976 were studied. On echocardiography, 7,500 (56%) had mitral regurgitation (8.8% severe MR), 6,449(48.2%) had tricuspid regurgitation (7.1% severe TR) and 5,550 (41.4%) had aortic regurgitation (4.8% severe AR). MS was detected in 2,729 (20.3%) patients (15.3% severe MS), AS in 102 (0.8%) and TS in 31 (0.2%) patients. Mixed mitral valve disease was seen in 3,185 (23.7%), mixed aortic valve disease in 222 (1.7%) and mixed tricuspid valve disease in 47 (0.4%) patients. All three valves were involved in 2,826 (21.06%) patients, combination of mitral and aortic valves in 3,103 (23.13%), mitral and tricuspid in 3,784 (28.2 %), and mitral only in 3,701 (27.59%) patients. There was some mitral valve abnormality in all patients. Conclusion: Mitral valve was most commonly affected, while regurgitant lesions were more common than stenotic lesions, and most severe in younger patients. All valvular lesions had almost an equal distribution among the sexes, except aortic regurgitation, which was more common in females. Therefore, echocardiography should be done routinely for patients with RHD, focusing on younger population, to facilitate diagnosis and definitive treatment before complications set in. (author)

  3. On-Orbit Prospective Echocardiography on International Space Station

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2010-01-01

    A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

  4. Echocardiographic evaluation of the heart repercussions of different sport modalities in athletes of high yield

    International Nuclear Information System (INIS)

    Chaves, Angel Maria; Melo, German; Conde, Carlos Arturo; Vesga, Boris Eduardo

    2002-01-01

    The paper compares anthropometry and echocardiographic changes secondary to longest training in elite athletes. They were not differences in the ejection fraction, stroke volume and systolic wall stress. Differences were found in septum thickness, posterior wall thickness in dynamic and combined groups. This finding suggest morphological changes similar to left ventricular hypertrophy

  5. Global Longitudinal Strain Is a Superior Predictor of All-Cause Mortality in Heart Failure With Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Sengeløv, Morten; Jørgensen, Peter Godsk; Jensen, Jan Skov

    2015-01-01

    failure clinic. The echocardiographic images were analyzed, and conventional and novel echocardiographic parameters were obtained. RESULTS: Many of the conventional echocardiographic parameters proved to be predictors of mortality. However, GLS remained an independent predictor of mortality...

  6. Physiological pulmonary branch stenosis in newborns: 2D-echocardiographic and Doppler characteristics and 4 months follow up

    Directory of Open Access Journals (Sweden)

    Amer Yazdanparast

    2004-02-01

    Full Text Available Transient systolic murmurs in neonates and premature infants due to mild left (LPA and right (RPA pulmonary branch stenosis is recognized but follow up studies are lacking. A total of 32 neonates with murmur and 32 controls were evaluated echocardiographically at baseline and in four months follow up. Diameters of LPA and RPA were smaller in patients with murmur. Colour-coded Doppler showed turbulent flow in LPA and RPA in 93% of patients and flow velocities of both pulmonary branches were significantly higher than in controls. The follow up study at 4 months showed absent (23% or decreased murmur (76%. Echocardiographically, absolute and relative diameters of LPA and RPA increased whereas the ratio of main pulmonary artery/aorta did not change suggesting accelerated growth or dilatation of the pulmonary branches. Thus, transient systolic murmurs in neonates are associated with temporary relative hypoplasia of the pulmonary branches which showed increased growth leading to disappearance of the murmur in most cases within 4 months of life.

  7. Computer-assisted determination of left ventricular endocardial borders reduces variability in the echocardiographic assessment of ejection fraction

    Directory of Open Access Journals (Sweden)

    Lindstrom Lena

    2008-11-01

    Full Text Available Abstract Background Left ventricular size and function are important prognostic factors in heart disease. Their measurement is the most frequent reason for sending patients to the echo lab. These measurements have important implications for therapy but are sensitive to the skill of the operator. Earlier automated echo-based methods have not become widely used. The aim of our study was to evaluate an automatic echocardiographic method (with manual correction if needed for determining left ventricular ejection fraction (LVEF based on an active appearance model of the left ventricle (syngo®AutoEF, Siemens Medical Solutions. Comparisons were made with manual planimetry (manual Simpson, visual assessment and automatically determined LVEF from quantitative myocardial gated single photon emission computed tomography (SPECT. Methods 60 consecutive patients referred for myocardial perfusion imaging (MPI were included in the study. Two-dimensional echocardiography was performed within one hour of MPI at rest. Image quality did not constitute an exclusion criterion. Analysis was performed by five experienced observers and by two novices. Results LVEF (%, end-diastolic and end-systolic volume/BSA (ml/m2 were for uncorrected AutoEF 54 ± 10, 51 ± 16, 24 ± 13, for corrected AutoEF 53 ± 10, 53 ± 18, 26 ± 14, for manual Simpson 51 ± 11, 56 ± 20, 28 ± 15, and for MPI 52 ± 12, 67 ± 26, 35 ± 23. The required time for analysis was significantly different for all four echocardiographic methods and was for uncorrected AutoEF 79 ± 5 s, for corrected AutoEF 159 ± 46 s, for manual Simpson 177 ± 66 s, and for visual assessment 33 ± 14 s. Compared with the expert manual Simpson, limits of agreement for novice corrected AutoEF was lower than for novice manual Simpson (0.8 ± 10.5 vs. -3.2 ± 11.4 LVEF percentage points. Calculated for experts and with LVEF (% categorized into Conclusion Corrected AutoEF reduces the variation in measurements compared with

  8. Evaluation of Cardiovascular System in Fibromyalgia Syndrome: Tissue Doppler Echocardiographic Investigation

    Directory of Open Access Journals (Sweden)

    Selma YAZICI

    2010-05-01

    Full Text Available Aim: We aim to investigate besides the cardiac structures and functions by both conventionalmethods and Tissue Doppler Echocardiography (TDE which is a new and useful method inpatients with Fibromyalgia (FM. Additionally, we evaluated QT parameters (QT maximum,QT minimum and QT dispertion with the use of electrocardiography in order to measure theautonomic dysfunction which is a possible mechanism in the pathogenesis of the disease. Methods: The study was performed on 42 patients (mean age 41 years, 38 female and 38completely healthy subjects (35 female, mean age of 42 years who were admitted to the sameclinic were collected as the control group. All the individuals were undergone a completephysical examination, electrocardiography (recordings were displayed at 50 mm/s speed andechocardiography evaluation (both conventional methods and TDE.Results: Analysis of electrocardiographic recordings revealed mildly increased mean QTdispertion in the patient group, but this difference was statistically insignificant. Analysis ofconventional echocardiographic parameters revealed similar results between the patient groupand the control cases. However, an important finding of this study is that significant diastolicdysfunction was found in the patient group which was recorded with the TDE technique. Emwave velocity and Em/Am ratios were significantly lower in patients with FM compared withcontrols (p<0.005, p<0.01, respectively. Sm and Am waves velocities were similar in bothgroups. Conclusion: In this study, significant left ventricular diastolic dysfunction which was detectedby TDE technique can partly explain several symptoms such as fatigue and dyspnea in FM. Inaddition, fully cardiac evaluation of patients with FM might be obtained supporting findingsthe autonomic dysfunction theory in fibromyalgia pathogenesis.

  9. Intraoperative device closure of perimembranous ventricular septal defects in the young children under transthoracic echocardiographic guidance; initial experience

    Directory of Open Access Journals (Sweden)

    Cao Hua

    2011-12-01

    Full Text Available Abstract Objectives This study aimed to assess the safety and feasibility of intraoperative device closure of perimembranous ventricular septal defects (VSD in young children guided by transthoracic echocardiography (TTE. Methods We enrolled 18 patients from our hospital to participate in the study from June 2011 to September 2011. A minimal inferior median incision was performed after full evaluation of the perimembranous VSD by real-time TTE, and a domestically made device was inserted to occlude the perimembranous VSD. The proper size of the device was determined by means of transthoracic echocardiographic analysis. Results Implantation was ultimately successful in 16 patients using TTE guidance. In these cases, the complete closure rate immediately following the operation and on subsequent follow-up was 100%. Symmetric devices were used in 14 patients, and asymmetric devices were used in two patients. Two patient were transformed to surgical treatment, one for significant residual shunting, and the other for unsuccessful wire penetration of the VSD. The follow-up periods were less than nine months, and only one patient had mild aortic regurgitation. There were no instances of residual shunt, noticeable aortic regurgitation, significant arrhythmia, thrombosis, or device failure. Conclusions Minimally invasive transthoracic device closure of perimembranous VSDs is safe and feasible, using a domestically made device under transthoracic echocardiographic guidance, without the need for cardiopulmonary bypass. This technique should be considered an acceptable alternative to surgery or device closure guided by transesophageal echocardiography in selected young children. However, a long-term evaluation of outcomes is necessary.

  10. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  11. Structure and function of the tricuspid and bicuspid regurgitant aortic valve: an echocardiographic study.

    Science.gov (United States)

    Rönnerfalk, Mattias; Tamás, Éva

    2015-07-01

    The emerging new treatment options for aortic valve disease call for more sophisticated diagnostics. We aimed to describe the echocardiographic pathophysiology and characteristics of the purely regurgitant aortic valve in detail. Twenty-nine men, with chronic aortic regurgitation without concomitant heart disease referred for aortic valve intervention, underwent 2D transoesophageal echocardiographic (TEE) examination prior to surgery according to a previously published matrix. Measurements of the aortic valve apparatus in long and short axis view were made in systole and diastole and analysed off-line. The aortic valves were grouped as tricuspid (TAV) or bicuspid (BAV), and classified by regurgitation mechanism. Twenty-four examinations were eligible for analysis of which 13 presented TAV and 11 BAV. The regurgitation mechanism was classified as dilatation of the aorta in 6 cases, as prolapse in 11 cases and as poor cusp tissue quality or quantity in 7 cases. The ventriculo-aortic junction (VAJ) and valve opening were closely related (TAV r = 0.5, BAV r = 0.73) but no correlation was found between the VAJ and the maximal sinus diameter (maxSiD) or the sinotubular junction (STJ). However, the STJ and maxSiD were significantly related (TAV vs BAV: systole r = 0.9, r = 0.8; diastole r = 0.9, r = 0.7), forming an entity. The conjoined BAV cusps were shorter than the anterior cusps when closed (P = 0.002); the inter-commissural distances of the cusps in the BAV group were significantly different (P = 0.001 resp. 0.03) in both systole and diastole. The VAJ was independent of other aortic dimensions and should thereby be considered as a separate entity with influence on valve opening. The detailed 2D TEE measurements of this study add further important information to our knowledge about the function and echocardiographic anatomy of the pathological aortic valve and root either as a stand-alone examination or as a benchmark and complement to 3D echocardiography. This may

  12. Clinical, echocardiographic, and radiographic findings of peritoneopericardial diaphragmatic hernia in two dogs and a cat

    International Nuclear Information System (INIS)

    Hay, W.H.; Woodfield, J.A.; Moon, M.A.

    1989-01-01

    Peritoneopericardial diaphragmatic hernia was diagnosed in 2 dogs and a cat. One dog was referred because of clinical signs of cardiac tamponade and acute decompensation from liver entrapment within the hernia. Surgical correction of the hernia alleviated clinical signs in all 3 animals. Echocardiography was used in combination with radiography to provide a rapid and accurate diagnosis

  13. Echocardiographic estimation of right ventricular stroke work in children with pulmonary arterial hypertension: comparison with invasive measurements.

    Science.gov (United States)

    Di Maria, Michael V; Burkett, Dale A; Younoszai, Adel K; Landeck, Bruce F; Mertens, Luc; Ivy, D Dunbar; Friedberg, Mark K; Hunter, Kendall S

    2015-11-01

    Right ventricular (RV) failure is a key determinant of mortality in children with pulmonary arterial hypertension (PAH). RV stroke work (RVSW) can be estimated as the product of RV systolic pressure and stroke volume. The authors have shown that RVSW predicts adverse outcomes in this population when derived from hemodynamic data; noninvasive assessment of RVSW may be advantageous but has not been assessed. There are few data validating noninvasive versus invasive measurements in children with PAH. The aim of this study was to compare echocardiographically derived RVSW with RVSW determined from hemodynamic data. This was a retrospective study, including subjects with idiopathic PAH and minor or repaired congenital heart disease. Forty-nine subjects were included, in whom cardiac catheterization and echocardiography were performed within 1 month. Fourteen additional patients were included in a separate cohort, in whom catheterization and echocardiography were performed simultaneously. Catheterization-derived RVSW was calculated as RV systolic pressure × (cardiac output/heart rate). Echocardiographically derived RVSW was calculated as 4 × (peak tricuspid regurgitant jet velocity)(2) × (pulmonary valve area × velocity-time integral). Statistics included the intraclass correlation coefficient and Bland-Altman analysis. Echocardiographically derived RVSW was linearly correlated with invasively derived RVSW (r = 0.74, P work was related to indexed pulmonary vascular resistance (r = 0.43, P = .002), tricuspid annular plane systolic excursion (r = 0.41, P = .004), and RV wall thickness (r = 0.62, P work, a potential novel index of RV function, can be estimated noninvasively and is related to pulmonary hemodynamics and other indices of RV performance. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  14. Elevated serum leptin levels in patients with acute myocardial infarction; correlation with coronary angiographic and echocardiographic findings

    Directory of Open Access Journals (Sweden)

    Khafaji Hadi AR

    2012-05-01

    Full Text Available Abstract Background To assess the relationship between serial serum leptin levels in patients with acute myocardial infarction (AMI who received thrombolysis and the degree of coronary atherosclerosis, coronary reperfusion, echocardiographic findings, and clinical outcome. 51 consecutive patients presenting with AMI were studied. Clinical characteristics including age, sex, body mass index (BMI and cardiovascular risk factors were recorded. Serial serum leptin levels at the time of admission and subsequently at 0, 6, 12, 24, 36, 60 hours afterwards were obtained. Coronary angiography was performed in 34 patients; the relation between serum leptin levels and evidence of coronary reperfusion as well as the extent of coronary atherosclerosis according to the coronary artery surgery study classification (CASS were evaluated. Echocardiographic evaluation was performed in all patients. 36 matched patients were enrolled as control group who had serum leptin level 9.4 ± 6.5 ng/ml. Results The patients mean age was 50.5 ± 10.6 years. There were 47 males and 3 females. 37.1% were diabetics, 23.5% were hypertensive, 21.6% were dyslipidemic and 22.7% were obese (BMI ≥ 30. Leptin concentrations (ng/ml increased and peaked at the 4th sample (36 hrs after admission (mean ± SD sample (1 =9.55 ± 7.4, sample (2 =12.9 ± 8.4, sample (3 =13.8 ± 10.4, sample (4 =18.9 ± 18.1, sample (5 =11.4 ± 6.5, sample (6 =10.8 ± 8.9 ng/ml. There was a significant correlation between serum leptin and BMI (r = 0.342; p = 0.03. Leptin levels correlated significantly to creatine kinase level on the second day (r = 0.43, p ≤ 0.01. Significant correlation of mean serum leptin with the ejection fraction (P p = 0.8. There was a trend for an increase in the mean serum leptin levels with increasing number of diseased vessels. There was no correlation between serum leptin levels and outcome neither during the

  15. Evaluation of a clinically intuitive quality assurance method

    International Nuclear Information System (INIS)

    Norris, H; Thomas, A; Oldham, M

    2013-01-01

    There is a pressing need for clinically intuitive quality assurance methods that report metrics of relevance to the likely impact on tumor control of normal tissue injury. This paper presents a preliminary investigation into the accuracy of a novel ''transform method'' which enables a clinically relevant analysis through dose-volume-histograms (DVHs) and dose overlays on the patient's CT data. The transform method was tested by inducing a series of known mechanical and delivery errors onto simulated 3D dosimetry measurements of six different head-and-neck IMRT treatment plans. Accuracy was then examined through the comparison of the transformed patient dose distributions and the known actual patient dose distributions through dose-volume histograms and normalized dose difference analysis. Through these metrics, the transform method was found to be highly accurate in predicting measured patient dose distributions for these types of errors.

  16. Gender disparities in pulmonary hypertension at a tertiary centre in ...

    African Journals Online (AJOL)

    Background. Pulmonary hypertension (PH) is a potent cause of heart failure and has been little investigated in the African setting. Objective. To investigate the effects of gender on the clinical presentation, echocardiographic features and outcomes of patients with PH in Douala, Cameroon. Methods. A prospective cohort ...

  17. State-of-the-Art Review of Echocardiographic Imaging in the Evaluation and Treatment of Functional Tricuspid Regurgitation.

    Science.gov (United States)

    Hahn, Rebecca T

    2016-12-01

    Functional or secondary tricuspid regurgitation (TR) is the most common cause of severe TR in the Western world. The presence of functional TR, either isolated or in combination with left heart disease, is associated with unfavorable natural history. Surgical mortality for isolated tricuspid valve interventions remains higher than for any other single valve surgery, and surgical options for repair do not have consistent long-term durability. In addition, as more patients undergo transcatheter left valve interventions, developing transcatheter solutions for functional TR has gained greater momentum. Numerous transcatheter devices are currently in early clinical trials. All patients require an assessment of valve morphology and function, and transcatheter devices typically require intraprocedural guidance by echocardiography. The following review will describe tricuspid anatomy, define echocardiographic views for evaluating tricuspid valve morphology and function, and discuss imaging requirements for the current transcatheter devices under development for the treatment of functional TR. © 2016 American Heart Association, Inc.

  18. Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study

    DEFF Research Database (Denmark)

    Haaverstad, Rune; Vitale, Nicola; Karevold, Asbjørn

    2006-01-01

    OBJECTIVE: The aim of this report is the prospective, multicentre evaluation of clinical results and haemodynamic performance of the Medtronic Advantage aortic valve prosthesis. METHODS: From April 2001 to June 2003, 166 patients (male:female 125:41; mean (SD) age 61.8 (11.8) years) received...... an aortic advantage valve prosthesis. Complete cumulative follow-up was 242.7 patient-years (maximum 3.2; mean 1.6 years). Postoperatively, patients underwent early (within 30 days) and 1 year transthoracic echocardiography. RESULTS: 30 day mortality was 2.4% (n = 4). Kaplan-Meier estimates of freedom from...... echocardiography. CONCLUSIONS: Haemodynamic performance and early clinical results of Medtronic advantage in the aortic position were satisfactory and comparable with those of other bileaflet valves in current clinical use....

  19. The relationship between BNP, NTproBNP and echocardiographic measurements of systemic blood flow in very preterm infants.

    Science.gov (United States)

    König, K; Guy, K J; Walsh, G; Drew, S M; Watkins, A; Barfield, C P

    2014-04-01

    Preterm infants are at risk of circulatory compromise following birth. Functional neonatal echocardiography including superior vena cava (SVC) flow is increasingly used in neonatal medicine, and low SVC flow has been associated with adverse outcome. However, echocardiography is not readily available in many neonatal units and B-type natriuretic peptides (BNPs) may be useful in guiding further cardiovascular assessment. This study investigated the relationship between BNP, N-terminal pro-BNP (NTproBNP) and echocardiographic measurements of systemic blood flow in very preterm infants. This is a prospective observational study. Sixty preterm infants flow, left and right ventricular output (LVO and RVO). Statistical analysis included simple linear regression of BNP and NTproBNP with echocardiographic measures and multiple regression including potential confounding variables. Mean (s.d.) gestational age at birth was 27(5) (2(1)) weeks, median (interquartile range, IQR) birth weight was 995 (845 to 1175) grams. Neither BNP nor NTproBNP correlated with SVC flow (BNP 95% confidence interval (CI) -0.0014 to 0.013, P=0.12; NTproBNP 95% CI -0.00069 to 0.01, P=0.085); LVO (BNP 95% CI -0.00078 to 0.0072, P=0.11; NTproBNP 95% CI -0.0034 to 0.0034, P=0.99); RVO (BNP 95% CI -0.00066 to 0.0058, P=0.12; NTproBNP 95% CI -0.0012 to 0.0044, P=0.25); or FS (BNP 95% CI -0.053 to 0.051, P=0.96; NTproBNP 95% CI -0.061 to 0.019, P=0.3). Multivariate linear regression did not significantly alter results. In this cohort of very preterm infants, BNP and NTproBNP did not correlate with echocardiographic measurements of systemic blood flow within the first 72 h of life.

  20. An Echocardiographic Study of Left Ventricular Size and Cardiac Function in Adolescent Females with Anorexia Nervosa.

    Science.gov (United States)

    Escudero, Carolina A; Potts, James E; Lam, Pei-Yoong; De Souza, Astrid M; Mugford, Gerald J; Sandor, George G S

    2016-01-01

    This retrospective case-control study investigated cardiac dimensions and ventricular function in female adolescents with anorexia nervosa (AN) compared with controls. Echocardiographic measurements of left ventricular (LV) dimensions, LV mass index, left atrial size and cardiac index were made. Detailed measures of systolic and diastolic ventricular function were made including tissue Doppler imaging. Patients were stratified by body mass index ≤10th percentile (AN ≤ 10th) and >10th percentile (AN > 10th). Ninety-five AN patients and 58 controls were included. AN and AN ≤ 10th groups had reduced LV dimensions, LV mass index, left atrial size and cardiac index compared with controls. There were no differences between groups in measures of systolic function. Measures of diastolic tissue Doppler imaging were decreased in AN and AN ≤ 10th. No differences in echocardiographic measurements existed between controls and AN > 10th. Female adolescents with AN have preserved systolic function and abnormalities of diastolic ventricular function. AN ≤ 10th may be a higher risk group. Copyright © 2015 John Wiley & Sons, Ltd and Eating Disorders Association.

  1. Echocardiographic left ventricular masses in distance runners and weight lifters

    Science.gov (United States)

    Longhurst, J. C.; Gonyea, W. J.; Mitchell, J. H.; Kelly, A. R.

    1980-01-01

    The relationships of different forms of exercise training to left ventricular mass and body mass are investigated by echocardiographic studies of weight lifters, long-distance runners, and comparatively sized untrained control subjects. Left ventricular mass determinations by the Penn convention reveal increased absolute left ventricular masses in long-distance runners and competitive weight lifters with respect to controls matched for age, body weight, and body surface area, and a significant correlation between ventricular mass and lean body mass. When normalized to lean body mass, the ventricular masses of distance runners are found to be significantly higher than those of the other groups, suggesting that dynamic training elevates left ventricular mass compared to static training and no training, while static training increases ventricular mass only to the extent that lean body mass is increased.

  2. Effectiveness of risk minimization measures for cabergoline-induced cardiac valve fibrosis in clinical practice in Italy.

    Science.gov (United States)

    Italiano, Domenico; Bianchini, Elisa; Ilardi, Maura; Cilia, Roberto; Pezzoli, Gianni; Zanettini, Renzo; Vacca, Laura; Stocchi, Fabrizio; Bramanti, Placido; Ciurleo, Rosella; Di Lorenzo, Giuseppe; Polimeni, Giovanni; de Luise, Cynthia; Ross, Douglas; Rijnbeek, Peter; Sturkenboom, Miriam; Trifirò, Gianluca

    2015-06-01

    On June 2008, the European Medicines Agency (EMA) introduced changes to the Summary of Product Characteristics (SPC) for cabergoline and pergolide, to reduce the risk of cardiac valvulopathy in users of these drugs. To assess the effectiveness of EMA recommendations in Italian clinical practice, we retrospectively reviewed medical charts of patients with degenerative Parkinsonism treated with cabergoline in three large Italian clinics between January 2006 and June 2012. The prevalence and the severity of cardiac valve regurgitation were assessed in patients who stopped cabergoline therapy prior to June 2008 or continued therapy after that date. In addition, the proportion of patients undergoing echocardiographic examination in each cohort was evaluated. A total of 61 patients were available for evaluation. The proportion of patients who underwent a baseline echocardiographic examination increased from 64 % in the period before the 2008 SPC changes to 71 % among those who continued treatment after that date. However, only 18 and 29 % of patients underwent at least two echocardiographic examinations during the pre-SPC and cross-SPC change period, respectively. No severe cardiac valve regurgitation was documented in any of the study patients using cabergoline either prior or after 26th June 2008. Our findings show that the 2008 changes to the SPC resulted in an increase in physicians' awareness of cabergoline-induced valvulopathy risk in Italy. However, only a small percentage of patients underwent serial echocardiography. Further efforts are needed to achieve better compliance with the prescribing guidelines for cabergoline treated patients in clinical practice.

  3. Endocardial Device Leads in Patients with Patent Foramen Ovale: Echocardiographic Correlates of Stroke/TIA and Mortality.

    Science.gov (United States)

    Ponamgi, Shiva P; Vaidya, Vaibhav R; Desimone, Christopher V; Noheria, Amit; Hodge, David O; Slusser, Joshua P; Ammash, Naser M; Bruce, Charles J; Rabinstein, Alejandro A; Friedman, Paul A; Asirvatham, Samuel J

    2017-03-01

    Echocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO. In 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow-up echocardiogram. Of 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow-up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time-dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447-2.189, P 10 mm Hg (HR 2.018, 95% CI 1.593-2.556, P TIA. However, a significantly higher TR or RVSP was associated with higher mortality. © 2016 Wiley Periodicals, Inc.

  4. Clinical impact of ' in-treatment' wall motion abnormalities in hypertensive patients with left ventricular hypertrophy: the LIFE study

    DEFF Research Database (Denmark)

    Cicala, S.; Simone, G. de; Wachtell, K.

    2008-01-01

    Objectives Left ventricular systolic wall motion abnormalities have prognostic value. Whether wall motion detected by serial echocardiographic examinations predicts prognosis in hypertensive patients with left ventricular hypertrophy ( LVH) without clinically recognized atherosclerotic disease ha...

  5. Nurse educators’ perceptions of OSCE as a clinical evaluation method

    Directory of Open Access Journals (Sweden)

    MM Chabeli

    2001-09-01

    Full Text Available The South African Qualifications Authority, and the South African Nursing Council are in pursuit of quality nursing education to enable the learners to practise as independent and autonomous practitioners. The educational programme should focus on the facilitation of critical and reflective thinking skills that will help the learner to make rational decisions and solve problems. A way of achieving this level of functioning is the use of assessment and evaluation methods that measure the learners’ clinical competence holistically. This article is focused on the perceptions of twenty nurse educators, purposively selected from three Nursing Colleges affiliated to a university in Gauteng, regarding the use of OSCE (Objective Structured Clinical Examination as a clinical evaluation method within a qualitative and descriptive research strategy. Three focus group interviews were conducted in different sessions. A descriptive content analysis was used. Trustworthiness was ensured by using Lincoln and Guba’s model (1985. The results revealed both positive and negative aspects of OSCE as a clinical evaluation method with regard to: administrative aspects; evaluators; learners; procedures/instruments and evaluation. The conclusion drawn from the related findings is that OSCE does not measure the learners’ clinical competence holistically. It is therefore recommended that the identified negative perception be taken as challenges faced by nurse educators and that the positive aspects be strengthened. One way of meeting these recommendations is the use of varied alternative methods for clinical assessment and evaluation that focus on the holistic measurement of the learners’ clinical competence.

  6. A 29-year-old Harken disk mitral valve: long-term follow-up by echocardiographic and cineradiographic imaging.

    Science.gov (United States)

    Hsi, David H; Ryan, Gerald F; Taft, Janice; Arnone, Thomas J

    2003-01-01

    An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patients 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features.

  7. Prognostic value of exercise echocardiography: validation of a new risk index combining echocardiographic, treadmill, and exercise electrocardiographic parameters.

    Science.gov (United States)

    Mazur, Wojciech; Rivera, Jose M; Khoury, Alexander F; Basu, Abhijeet G; Perez-Verdia, Alejandro; Marks, Gary F; Chang, Su Min; Olmos, Leopoldo; Quiñones, Miguel A; Zoghbi, William A

    2003-04-01

    Exercise (Ex) echocardiography has been shown to have significant prognostic power, independent of other known predictors of risk from an Ex stress test. The purpose of this study was to evaluate a risk index, incorporating echocardiographic and conventional Ex variables, for a more comprehensive risk stratification and identification of a very low-risk group. Two consecutive, mutually exclusive populations referred for treadmill Ex echocardiography with the Bruce protocol were investigated: hypothesis-generating (388 patients; 268 males; age 55 +/- 13 years) and hypothesis-testing (105 patients; 61 males age: 54 +/- 14 years).Cardiac events included cardiac death, myocardial infarction, late revascularization (>90 days), hospital admission for unstable angina, and admission for heart failure. Mean follow-up in the hypothesis-generating population was 3.1 years. There were 38 cardiac events. Independent predictors of events by multivariate analysis were: Ex wall motion score index (odds ratio [OR] = 2.77/Unit; P or = 1 mm (OR = 2.84; P =.002); and treadmill time (OR = 0.87/min; P =.037). A risk index was generated on the basis of the multivariate Cox regression model as: risk index = 1.02 (Ex wall motion score index) + 1.04 (S-T change) - 0.14 (treadmill time). The validity of this index was tested in the hypothesis-testing population. Event rates at 3 years were lowest (0%) in the lower quartile of risk index (-1.22 to -0.47), highest (29.6%) in the upper quartile (+0.66 to +2.02), and intermediate (19.2% to 15.3%) in the intermediate quartiles. The OR of the risk index for predicting cardiac events was 2.94/Unit ([95% confidence interval: 1.4 to 6.2]; P =.0043). Echocardiographic and Ex parameters are independent powerful predictors of cardiac events after treadmill stress testing. A risk index can be derived with these parameters for a more comprehensive risk stratification with Ex echocardiography.

  8. Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

    Science.gov (United States)

    Buckey, J. C.; Beattie, J. M.; Gaffney, F. A.; Nixon, J. V.; Blomqvist, C. G.

    1984-01-01

    Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

  9. Motion Mode and Two Dimensional Echocardiographic Measurements of Cardiac Dimensions of Indonesian Mongrel Dogs

    Directory of Open Access Journals (Sweden)

    DENI NOVIANA

    2011-03-01

    Full Text Available Prevalence of heart disease in dogs was very high and required early diagnosis through physical examination, electrocardiogram, and echocardiography. Normal reference values of echocardiography are highly breedspecific and need for comparison and evaluation of dogs suspected with heart disease. Therefore the aim of this study was to establish normal reference echocardiographic values for Indonesian mongrel dogs, specifically to find out intracardiac dimensions, wall thickness, and fractional shortening. Motion-mode and two-dimensional echocardiography from right parasternal short axis and long axis view were performed on nine clinically healthy dogs consisting of five males and four males. The results showed that wall thickness and fractional shortening of Indonesia mongrel dogs were higher compared with those in the other breed that have the same average weight. As opposite, the intracardiac dimensions and lumen dimensions of aorta and left atrial diameter were smaller. These differences might occur due to factors other than the dog's habits and functions such as working and hunting, but can also be caused by the existence of breed differences. There was no significant difference between male and female dogs in terms of intracardiac dimension systole (P = 0.53, diastole (P = 0.38, fractional shortening (P = 0.053, and the ratio of aorta and left atrial diameter (P = 0.06.

  10. Clinical Features of Ehlers-Danlos Syndrome

    Directory of Open Access Journals (Sweden)

    Jui-Lung Yen

    2006-01-01

    Conclusion: The results of this study emphasize the importance of echocardiographic monitoring of aortic size and valvular condition, and assessment of bone mineral density in patients with EDS. Clinical evaluation and counseling should be undertaken prior to pregnancy in patients with EDS because of the risk from labor and vaginal delivery in patients with type IV and the inability to distinguish EDS subtypes in Taiwan due to the unavailability of biochemical assay or molecular mutation analysis as part of standard care.

  11. Chronic valvular disease: correlation between clinical, electrocardiographic, radiographic and echocardiographic aspects in dogs Doença valvar crônica: correlação entre aspectos clínicos, eletrocardiográficos, radiográficos e ecocardiográficos em cães

    Directory of Open Access Journals (Sweden)

    E.C. Soares

    2005-08-01

    Full Text Available Echocardiographic aspects of chronic mitral valvular disease were studied and compared to physical, radiographic and electrocardiographic aspects. Seventy dogs were used, and clinical examination, thoracic radiography, electrocardiogram and echocardiogram were performed. Correlations between regurgitation severity with cardiac failure functional class and murmur intensity were observed. The electrocardiogram showed a low sensibility in detecting cardiac chamber enlargement, caused by mitral regurgitation. All the dogs with severe mitral regurgitation showed cardiomegaly according to thoracic radiographies.Avaliaram-se os aspectos ecocardiográficos da doença valvar crônica, comparando-os com os aspectos clínicos, radiográficos e eletrocardiográficos em cães. Estudaram-se 70 animais, realizando-se exames físicos, radiografias torácicas, eletrocardiograma e ecocardiograma. Observaram-se correlações entre a gravidade da regurgitação, a classe funcional da insuficiência cardíaca e a intensidade de sopro. O eletrocardiograma mostrou baixa sensibilidade para detectar aumento de câmaras cardíacas causadas por regurgitação mitral. Todos os cães com regurgitação mitral grave apresentaram cardiomegalia nas radiografias torácicas.

  12. Mitral valve prolapse in Zaria: clinical and echocardiographic features

    African Journals Online (AJOL)

    Background: Mitral valve prolapse (MVP) symptomatology and presentation are said to be of questionable significance. Method: A prospective study of 10 patients with mitral valve prolapse seen at Ahmadu Bello University Hospital in two years. Results: There were six females and four males. Their ages ranged from 5 to ...

  13. Echocardiographic evaluation of patients with subacute sclerosing panencephalitis

    Directory of Open Access Journals (Sweden)

    Derya Çimen

    2014-03-01

    Full Text Available Objective: Subacute sclerosing panencephalitis is a slowly progressive, inflammatory and neurodegenerative disease caused by virus infection in the central nervous system. Since there are a limited number of studies in the literature evaluating the cardiovascular functions of patients with SSPE, the present study evaluates the patients with SSPE using tissue Doppler echocardiography and compares them between the control group in order to shed some light on the subject. Methods: The study is a prospective observational study. 49 patients (17 female, 32 male with SSPE were included in the study. Patients were divided into two groups: Stage 2 (n=29 and Stage 3 (n=20. Echocardiographic data were compared with a control group of 26 which is the same average age. All children underwent a detailed echocardiography, which contained an M-mode, pulse Doppler and tissue Doppler imaging. Results: Sinus tachycardia ( >100 beats/min in children was detected in nineteen (38.7% patients. There were not significant differences between parameters of systolic and diastolic function of the heart. Stage 2 group, EF: 69.9±6.4; SF: 39.2±5.58; and MPI (mitral: 0.38±0.03 and MPI (tricuspid: 0.39±0.10. And in the Stage 3 group, EF: 68.5±7.0, SF: 37.8±5.34, MPI (mitral: 0.37±0.09 and MPI (tricuspid: 0.38±0.12. In the control group EF:70.96±5.54; SF:39.96±5.05 and MPI(mitral: 0.35±0.06 MPI (tricuspid:0.36±0.04 and statistically meaningful differences were not found between patients and control groups (p >0.05. Conclusion: Cardiac functions may be preserved and cardiac functions constitute no significant risks of mortality in the advanced stages of patients with Subacute sclerosing panencephalitis, which is a group of chronic and bedridden patients.

  14. A Cognitive Machine Learning Algorithm for Cardiac Imaging: A Pilot Study for Differentiating Constrictive Pericarditis from Restrictive Cardiomyopathy

    Science.gov (United States)

    Sengupta, Partho P.; Huang, Yen-Min; Bansal, Manish; Ashrafi, Ali; Fisher, Matt; Shameer, Khader; Gall, Walt; Dudley, Joel T

    2016-01-01

    Background Associating a patient’s profile with the memories of prototypical patients built through previous repeat clinical experience is a key process in clinical judgment. We hypothesized that a similar process using a cognitive computing tool would be well suited for learning and recalling multidimensional attributes of speckle tracking echocardiography (STE) data sets derived from patients with known constrictive pericarditis (CP) and restrictive cardiomyopathy (RCM). Methods and Results Clinical and echocardiographic data of 50 patients with CP and 44 with RCM were used for developing an associative memory classifier (AMC) based machine learning algorithm. The STE data was normalized in reference to 47 controls with no structural heart disease, and the diagnostic area under the receiver operating characteristic curve (AUC) of the AMC was evaluated for differentiating CP from RCM. Using only STE variables, AMC achieved a diagnostic AUC of 89·2%, which improved to 96·2% with addition of 4 echocardiographic variables. In comparison, the AUC of early diastolic mitral annular velocity and left ventricular longitudinal strain were 82.1% and 63·7%, respectively. Furthermore, AMC demonstrated greater accuracy and shorter learning curves than other machine learning approaches with accuracy asymptotically approaching 90% after a training fraction of 0·3 and remaining flat at higher training fractions. Conclusions This study demonstrates feasibility of a cognitive machine learning approach for learning and recalling patterns observed during echocardiographic evaluations. Incorporation of machine learning algorithms in cardiac imaging may aid standardized assessments and support the quality of interpretations, particularly for novice readers with limited experience. PMID:27266599

  15. Compass: A hybrid method for clinical and biobank data mining

    DEFF Research Database (Denmark)

    Krysiak-Baltyn, Konrad; Petersen, Thomas Nordahl; Audouze, Karine Marie Laure

    2014-01-01

    We describe a new method for identification of confident associations within large clinical data sets. The method is a hybrid of two existing methods; Self-Organizing Maps and Association Mining. We utilize Self-Organizing Maps as the initial step to reduce the search space, and then apply...... Association Mining in order to find association rules. We demonstrate that this procedure has a number of advantages compared to traditional Association Mining; it allows for handling numerical variables without a priori binning and is able to generate variable groups which act as “hotspots” for statistically...... significant associations. We showcase the method on infertility-related data from Danish military conscripts. The clinical data we analyzed contained both categorical type questionnaire data and continuous variables generated from biological measurements, including missing values. From this data set, we...

  16. Echocardiographic evaluation and N-terminal pro-brain natriuretic peptide measurement of patients hospitalized for heart failure during weaning from mechanical ventilation.

    Science.gov (United States)

    Gerbaud, E; Erickson, M; Grenouillet-Delacre, M; Beauvieux, M-C; Coste, P; Durrieu-Jaïs, C; Hilbert, G; Castaing, Y; Vargas, F

    2012-04-01

    Weaning patients with heart failure who have required mechanical ventilation remains challenging. We evaluated echocardiographic indexes and N-terminal pro-brain natriuretic peptide (NT-proBNP) as markers of acute cardiac dysfunction before and after spontaneous breathing trials (SBT) in such patients to assess their ability to predict subsequent successful extubation. Forty-four patients who underwent their first SBT were prospectively included. Plasma levels of NT-proBNP and transthoracic echocardiography indices including cardiac index, E/A ratio and E/Ea ratio were recorded immediately before commencing and just before the end of SBT. Ten patients (22.7%) failed their SBT. No significant difference was observed concerning baseline echocardiographic data and NT-proBNP level between the patients who succeeded the SBT or those that failed. Cardiac index increased significantly at end-SBT in patients who passed (3.3 [3.06-3.77] vs. 3 [2.68-3.3] L/min/m(2), Pfailed. E/Ea ratio (16.8 [8.5-27.3] vs. 10.7 [6.7-20.5], P=0.006) and NT-proBNP level (8199 [3106-10949] vs. 4200 [1855-7125] pg/mL, P=0.004) increased significantly in those who failed the SBT, in contrast to the weaning success group where they remained unchanged. Neither NT-proBNP level nor the studied echocardiographic indices before SBT were able to predict SBT outcome in patients presenting with severe heart failure. Failure to increase the cardiac index and increases in both E/Ea ratio and NT-proBNP levels were seen at end-SBT in patients who failed the SBT, and may reflect failure of myocardial reserve to cope with the stress of SBT.

  17. Echocardiographic study of cardiac dysfunction in patients of chronic kidney disease on hemodialysis

    International Nuclear Information System (INIS)

    Arshi, S.; Butt, G.U.D.; Mian, F.A.

    2016-01-01

    Objective: The objective of this study was to see echocardiographic findings of cardiac dysfunction in patients of chronic kidney disease (CKD) on hemodialysis. Study Design: Comparative cross sectional study. Place and Duration of Study: Department of nephrology, Pakistan Institute of Medical Sciences. Islamabad from September 2014 to February 2015. Patients and Methods: One hundred patients of either gender were included in this study. Fifty patients of chronic kidney disease stage V on hemodialysis were taken for echocardiography and fifty were normal. Echocardiography was done for cardiac dysfunction. Systolic function was measured by ejection fraction (EF) and fractional shortening (FS). Diastolic function was measured by E/A ratio. Results: Out of 100 patients included in the study, 50 patients were on hemodialysis and 50 were control. Left ventricular end systolic and end diastolic volumes were higher in patients on hemodialysis than controls as well as left atrial enlargement and inter ventricular septum which was statistically significant. Ejection fraction, although normal and fractional shortening decreased in patients on hemodialysis (p<0.05). Diastolic dysfunction was present in 36 patients on hemodialysis, while absent in the control group. Conclusion: Patients with chronic kidney disease on hemodialysis have higher prevalence of cardiac dysfunction. (author)

  18. Adaptive design methods in clinical trials – a review

    Directory of Open Access Journals (Sweden)

    Chang Mark

    2008-05-01

    Full Text Available Abstract In recent years, the use of adaptive design methods in clinical research and development based on accrued data has become very popular due to its flexibility and efficiency. Based on adaptations applied, adaptive designs can be classified into three categories: prospective, concurrent (ad hoc, and retrospective adaptive designs. An adaptive design allows modifications made to trial and/or statistical procedures of ongoing clinical trials. However, it is a concern that the actual patient population after the adaptations could deviate from the originally target patient population and consequently the overall type I error (to erroneously claim efficacy for an infective drug rate may not be controlled. In addition, major adaptations of trial and/or statistical procedures of on-going trials may result in a totally different trial that is unable to address the scientific/medical questions the trial intends to answer. In this article, several commonly considered adaptive designs in clinical trials are reviewed. Impacts of ad hoc adaptations (protocol amendments, challenges in by design (prospective adaptations, and obstacles of retrospective adaptations are described. Strategies for the use of adaptive design in clinical development of rare diseases are discussed. Some examples concerning the development of Velcade intended for multiple myeloma and non-Hodgkin's lymphoma are given. Practical issues that are commonly encountered when implementing adaptive design methods in clinical trials are also discussed.

  19. Echocardiographic indexes help predict the need for nuclear magnetic resonance evaluation of patients with repaired Tetralogy of Fallot

    International Nuclear Information System (INIS)

    Ferreiro, Myriam; Toro, Lida; Andia, Marcelo; Zelada, Pamela; Alcantara, Alex; Castillo, Maria Elisa; Lagos, Rosa; Bareno, Sandra; Uribe, Sergio

    2013-01-01

    Background: Pulmonary insufficiency (PI) frequently appears long-term after repair of Tetralogy of Fallot (TOFr). Cardiac magnetic resonance (CMR) plays a fundamental role in the indication of pulmonary valve replacement, in order to avoid complications of PI. However, CMR is a scarce and expensive resource in our reality, which is why its indication must be optimized. Aim: The objective of this work is to find echocardiographic indices to identify patients with TOFr with dilated RV and reduced ejection fraction (EF) Method: Images from echocardiograms (ECHO) and CMR in 20 patients (9 women, 8-25 years of age, average 15,8 years old) with TOFr were retrospectively reviewed. From ECHO images we obtained measurements for tricuspid annular plane systolic excursion (TAPSE), tissular s wave, isovolumetric acceleration (IVA), and severity of PI (mild, moderate, or severe). From CMR images, we measured EF, end diastolic volume (EDV) of the RV, and regurgitant fraction (RF) of the pulmonary artery. We performed a multivariate statistical analysis to explore the relation between ECHO parameters and CMR findings Results: No correlation was found between individual ECHO parameters and EDV or RV EF. However, we did find a model based on the TAPSE and PI that was able to predict the EDV of the RV with an r2 = 0.6. (FDV-RV = 8.60*TAPSE + 36.19*PI - 77.213). After comparing the PI with RF, we found that that echocardiography could correctly distinguish cases with mild PI from those with severe PI (p<0.001), or moderate from severe (p=0.004), but not mild from moderate PI Conclusion: In this preliminary study, we found a statistical model based on the TAPSE and PI which could be useful in the selection of patients with TOFr that are referred to CMR. While this study needs to be validated on a greater number of patients, it indicates the relevance of some echocardiographic parameters, which should always be included in the evaluation of patients with TOFr

  20. Echocardiographic predictors of coil vs device closure in patients undergoing percutaneous patent ductus arteriosus closure.

    Science.gov (United States)

    Roushdy, Alaa; Abd El Razek, Yasmeen; Mamdouh Tawfik, Ahmed

    2018-01-01

    To determine anatomic and hemodynamic echocardiographic predictors for patent ductus arteriosus (PDA) device vs coil closure. Seventy-six patients who were referred for elective transcatheter PDA closure were enrolled in the study. All patients underwent full echocardiogram including measurement of the PDA pulmonary end diameter, color flow width and extent, peak and end-diastolic Doppler gradients across the duct, diastolic flow reversal, left atrial dimensions and volume, left ventricular sphericity index, and volumes. The study group was subdivided into 2 subgroups based on the mode of PDA closure whether by coil (n = 42) or device (n = 34). Using univariate analysis there was a highly significant difference between the 2 groups as regard the pulmonary end diameter measured in both the suprasternal and parasternal short-axis views as well as the color flow width and color flow extent (P closure group had statistically significant higher end-systolic and end-diastolic volumes indexed, left atrial volume, and diastolic flow reversal. Receiver operating characteristic curve analysis showed a pulmonary end diameter cutoff point from the suprasternal view > 2.5 mm and from parasternal short-axis view > 2.61 mm to have the highest balanced sensitivity and specificity to predict the likelihood for device closure (AUC 0.971 and 0.979 respectively). The pulmonary end diameter measured from the suprasternal view was the most independent predictor of device closure. The selection between PDA coil or device closure can be done on the basis of multiple anatomic and hemodynamic echocardiographic variables. © 2017 Wiley Periodicals, Inc.

  1. Cardiac resynchronization therapy in a patient with amyloid cardiomyopathy.

    Science.gov (United States)

    Zizek, David; Cvijić, Marta; Zupan, Igor

    2013-06-01

    Cardiac involvement in systemic light chain amyloidosis carries poor prognosis. Amyloid deposition in the myocardium can alter regional left ventricular contraction and cause dyssynchrony. Cardiac resynchronization therapy (CRT) is an effective treatment strategy for patients with advanced heart failure and echocardiographic dyssynchrony. We report a clinical and echocardiographic response of a patient with amyloid cardiomyopathy, treated with a combination of chemotherapy and CRT.

  2. Effect of dobutamine on a Doppler echocardiographic index of combined systolic and diastolic performance.

    Science.gov (United States)

    Harada, K; Tamura, M; Toyono, M; Yasuoka, K

    2002-01-01

    Dobutamine stress echocardiography has become accepted in the evaluation of cardiac functional reserve. Although the Doppler-derived index of combined systolic/diastolic myocardial performance (Tei index) has been reported to be easily obtainable and useful for predicting left ventricular performance, the effect of dobutamine on the Tei index has not been determined in children. To assess the effect of dobutamine on the Tei index, 8 patients who had undergone surgery for ventricular septal defect and 7 patients who had a history of Kawasaki disease were examined. Echocardiographic recordings were obtained before and after dobutamine infusion (5 microg/kg per minute). Variables measured were transmitral flow velocities (E, A, E/A), rate-corrected mean velocity of circumferential fiber shortening (rate-corrected Vcf), and IMP. We measured isovolumic contraction time (ICT), isovolumic relaxation time (IRT), and ejection time (ET) and then calculated the Tei index using the following formula: Tei index = (ICT + IRT)/ET. Dobutamine infusion increased rate-corrected Vcf (29%, p ICT, and IRT were found to decrease during dobutamine infusion. The magnitude of the change in the ICT (-21%, p ICT/ET (-21%, p effects of inotropic stimilation on global left ventricular function.

  3. Atresia of the bilateral pulmonary veins: a rare and dismal anomaly identified on cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Park, Sang-Hyub; Koo, Hyun Jung; Cho, Young Hoon; Lee, Eunsol [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2014-08-15

    Imaging findings of bilateral pulmonary vein atresia have not been described. To describe cardiac CT findings and clinical outcomes of bilateral pulmonary vein atresia. Three newborns with bilateral pulmonary vein atresia were encountered at our institution during a period of 8 years. We evaluated prenatal echocardiographic findings, clinical presentations, postnatal echocardiographic findings, chest radiographic findings, cardiac CT findings and clinical outcomes. All newborns presented immediately after birth with severe cyanosis, respiratory distress and acidosis that were unresponsive to medical management. Prenatal and postnatal echocardiographic studies and chest radiography were misleading, inconclusive or nonspecific in making the diagnosis in these children; however cardiac CT clearly demonstrated atresia of the bilateral pulmonary veins with multiple small mediastinal collateral veins and pulmonary edema. Surgical treatments were not feasible for this anomaly. Their clinical outcomes were universally dismal and all infants died within 3 days. Cardiac CT provides an accurate diagnosis of bilateral pulmonary vein atresia and leads to prompt treatment decision in these children. (orig.)

  4. Atresia of the bilateral pulmonary veins: a rare and dismal anomaly identified on cardiac CT

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, Sang-Hyub; Koo, Hyun Jung; Cho, Young Hoon; Lee, Eunsol

    2014-01-01

    Imaging findings of bilateral pulmonary vein atresia have not been described. To describe cardiac CT findings and clinical outcomes of bilateral pulmonary vein atresia. Three newborns with bilateral pulmonary vein atresia were encountered at our institution during a period of 8 years. We evaluated prenatal echocardiographic findings, clinical presentations, postnatal echocardiographic findings, chest radiographic findings, cardiac CT findings and clinical outcomes. All newborns presented immediately after birth with severe cyanosis, respiratory distress and acidosis that were unresponsive to medical management. Prenatal and postnatal echocardiographic studies and chest radiography were misleading, inconclusive or nonspecific in making the diagnosis in these children; however cardiac CT clearly demonstrated atresia of the bilateral pulmonary veins with multiple small mediastinal collateral veins and pulmonary edema. Surgical treatments were not feasible for this anomaly. Their clinical outcomes were universally dismal and all infants died within 3 days. Cardiac CT provides an accurate diagnosis of bilateral pulmonary vein atresia and leads to prompt treatment decision in these children. (orig.)

  5. Comparison of transcoelomic, contrast transcoelomic, and transesophageal echocardiography in anesthetized red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Rodriguez, Daniel; Nevarez, Javier G; Tully, Thomas N

    2012-10-01

    To assess the agreement and reliability of cardiac measurements obtained with 3 echocardiographic techniques in anesthetized red-tailed hawks (Buteo jamaicensis). 10 red-tailed hawks. Transcoelomic, contrast transcoelomic, and transesophageal echocardiographic evaluations of the hawks were performed, and cineloops of imaging planes were recorded. Three observers performed echocardiographic measurements of cardiac variables 3 times on 3 days. The order in which hawks were assessed and echocardiographic techniques were used was randomized. Results were analyzed with linear mixed modeling, agreement was assessed with intraclass correlation coefficients, and variation was estimated with coefficients of variation. Significant differences were evident among the 3 echocardiographic methods for most measurements, and the agreement among findings was generally low. Interobserver agreement was generally low to medium. Intraobserver agreement was generally medium to high. Overall, better agreement was achieved for the left ventricular measurements and for the transesophageal approach than for other measurements and techniques. Echocardiographic measurements in hawks were not reliable, except when the left ventricle was measured by the same observer. Furthermore, cardiac morphometric measurements may not be clinically important. When measurements are required, one needs to consider that follow-up measurements should be performed by the same echocardiographer and should show at least a 20% difference from initial measurements to be confident that any difference is genuine.

  6. Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis

    International Nuclear Information System (INIS)

    Gottsauner-Wolf, M.; Schedlmayer-Duit, J.; Porenta, G.; Gwechenberger, M.; Huber, K.; Glogar, D.; Probst, P.; Sochor, H.

    1996-01-01

    Measurement of global left ventricular function is important in the follow-up of cardiac patients and is a good prognostic indicator in acute cardiac situations. We compared quantitative measurements of global left ventricular function made with radionuclide angiography (RNA) and contrast cardiac ventriculography (CVG) to visual semiquantitative estimates from two-dimensional echocardiographic images (2D-echo). Three hundred and thirty-nine consecutive patients who underwent RNA were assessed with 2D-echo within 3 months. In addition, 92 of these patients also underwent CVG (correlation of ejection fraction between CVG and RNA: r=0.82; P<0.0001). The RNA mean ejection fractions in the four 2D-echo groups (0=normal, 1=slightly, 2=moderate, or 3=severe reduced left ventricular function) differed markedly (P<0.0001); however, there was overlapping among the groups (2D-echo score/RNA ejection fraction: 0=57.3%±12.8%; 1=46.0%±12.9%; 2=29.6%± 12.2%; and 3=24.6%±11.5%) and the difference between 2D-echo scores 2 and 3 was not significant. 2D-echo showed a good concordance in RNA classes (0=≥505; 1=35%-49%; 2=21%-34%; and 3=≤20% ejection fraction) 0 (133/166; 80%) and 3 (18/30; 60%) but low concordance in classes 1 (27/82; 33%) and 2 (21/61; 34%). For accurate assessment of global left ventricular ejection fraction, visual semiquantitative judgement of a 2D echocardiographic image is limited in comparison to CVG or RNA, especially in patients with a slight or moderate reduction in left ventricular ejection fraction. (orig.). With 2 figs., 2 tabs

  7. Clinical and electrophysiological characteristics of patients with paroxysmal intra-His block with narrow QRS complexes.

    Science.gov (United States)

    Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B

    2018-04-18

    Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  8. Electrocardiographic, echocardiographic, and indirect blood pressure evaluation in dogs subjected to different sedation protocols

    Directory of Open Access Journals (Sweden)

    Helena Mondardo Cardoso

    Full Text Available ABSTRACT: The present study aimed to evaluate the effects of different sedation protocols on blood pressure and echocardiographic and electrocardiographic parameters in dogs. In total, 24 male mixed-breed dogs with a mean weight of 9.87±3.0kg were used.Animals were randomly divided into four groups (n=6, which were subjected to sedation using the following protocols: acepromazine (0.05mgkg-1 and butorphanol (0.3mgkg-1 (AB; acepromazine (0.05mgkg-1and methadone (0.5mgkg-1 (AM; acepromazine (0.03mgkg-1, methadone (0.5mgkg-1, and midazolam (0.3mgkg-1(MAM; and methadone only (0.5mgkg-1 (M. Indirect blood pressure (BP measurements and computerized electrocardiography (ECG and echocardiography (ECO were performed immediately before the application of the sedation protocol (baseline, and the same evaluations were repeated after 15 minutes. BP decreased in groups AB, MAM, and AM compared to baseline values. Electrocardiographic measurements showed decreased heart rates (HRs after sedation in all groups, and bradycardia was observed after sedation in two dogs from group M and one animal from group AM. The P-wave duration increased after sedation in groups AM and M. After sedation, no changes in cardiac dimensions were revealed byECO.Fractional shortening (FS decreased after sedation in the AM group, and dogs from group AB exhibited a smaller decrease in FS compared with the other groups. The cardiac index (CI was lower in groups AM and M than in the other groups. Animals from group AB were less resistant to examination and exhibited the most favorable sedation scores. It was concluded that the combination of acepromazine and butorphanol was the best sedation protocol for performing echocardiogram measurementsbecause dogs were less resistant to examinations and echocardiographic parameters of FS and CI remained stable.

  9. A method to adjust radiation dose-response relationships for clinical risk factors

    DEFF Research Database (Denmark)

    Appelt, Ane Lindegaard; Vogelius, Ivan R

    2012-01-01

    Several clinical risk factors for radiation induced toxicity have been identified in the literature. Here, we present a method to quantify the effect of clinical risk factors on radiation dose-response curves and apply the method to adjust the dose-response for radiation pneumonitis for patients...

  10. Longitudinal association of short-term, metronome-paced heart rate variability and echocardiographically assessed cardiac structure at a 4-year follow-up: results from the prospective, population-based CARLA cohort.

    Science.gov (United States)

    Medenwald, Daniel; Swenne, Cees A; Frantz, Stefan; Nuding, Sebastian; Kors, Jan A; Pietzner, Diana; Tiller, Daniel; Greiser, Karin H; Kluttig, Alexander; Haerting, Johannes

    2017-12-01

    To assess the value of cardiac structure/function in predicting heart rate variability (HRV) and the possibly predictive value of HRV on cardiac parameters. Baseline and 4-year follow-up data from the population-based CARLA cohort were used (790 men, 646 women, aged 45-83 years at baseline and 50-87 years at follow-up). Echocardiographic and HRV recordings were performed at baseline and at follow-up. Linear regression models with a quadratic term were used. Crude and covariate adjusted estimates were calculated. Missing values were imputed by means of multiple imputation. Heart rate variability measures taken into account consisted of linear time and frequency domain [standard deviation of normal-to-normal intervals (SDNN), high-frequency power (HF), low-frequency power (LF), LF/HF ratio] and non-linear measures [detrended fluctuation analysis (DFA1), SD1, SD2, SD1/SD2 ratio]. Echocardiographic parameters considered were ventricular mass index, diastolic interventricular septum thickness, left ventricular diastolic dimension, left atrial dimension systolic (LADS), and ejection fraction (Teichholz). A negative quadratic relation between baseline LADS and change in SDNN and HF was observed. The maximum HF and SDNN change (an increase of roughly 0.02%) was predicted at LADS of 3.72 and 3.57 cm, respectively, while the majority of subjects experienced a decrease in HRV. There was no association between further echocardiographic parameters and change in HRV, and there was no evidence of a predictive value of HRV in the prediction of changes in cardiac structure. In the general population, LADS predicts 4-year alteration in SDNN and HF non-linearly. Because of the novelty of the result, analyses should be replicated in other populations. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions please email: journals.permissions@oup.com.

  11. Evolução tardia da comissurotomia mitral em pacientes reumáticos com baixo escore ecocardiográfico Long-term evolution of mitral commissurotomy in rheumatic patients with low echocardiographic score

    Directory of Open Access Journals (Sweden)

    Luciano Rapold Souza

    2011-09-01

    Full Text Available INTRODUÇÃO: Os bons resultados da comissurotomia mitral a céu aberto são bem conhecidos e existe a hipótese de que se poderiam obter melhores resultados em pacientes selecionados pelo escore ecocardiográfico. OBJETIVO: Analisar os resultados tardios da comissurotomia mitral em pacientes selecionados pelo escore ecocardiográfico e identificar variáveis com influência nesses resultados. MÉTODOS: De janeiro de 1990 a agosto de 1994, 50 pacientes com estenose mitral reumática foram submetidos à comissurotomia mitral a céu aberto no Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Foram incluídos pacientes com idade INTRODUCTION: The good results of open mitral commissurotomy are well known and there is a hypothesis that it could provide better results in patients selected by echocardiographic score. OBJECTIVE: The purpose of this study is to analyze the late results with open mitral commissurotomy in patients selected by score and to identify variables influencing these results. METHODS: From January 1990 to August 1994, 50 patients were submitted to open mitral commissurotomy due to rheumatic mitral stenosis in Heart Institute of University of Sao Paulo Medical School. Patients with age < 60 years, in functional class II, III or IV (New York Heart Association and echocardiographic score 9 were included. The mean age was 32.7 ± 8.3 years and 41 patients (82% were female. The functional class was II in three patients (6%, III in 46 (92% and IV in one (2%. Forty six patients (92% were in sinus rhythm and four (8% were in atrial fibrillation. The mean mitral valve area was 0.9 ± 0.2 cm². RESULTS: There was no hospital mortality. There were two late deaths, one related to valve disease. Actuarial survival was 95.5 ± 3.1 %, freedom from reoperation was 62.3 ± 11,8% and freedom from tromboembolism was 88,2 ± 5,0% in 18 years. There was no endocarditis. The grade of the

  12. Echocardiographic assessment of right ventricular functions in healthy subjects who migrated from the sea level to a moderate altitude.

    Science.gov (United States)

    Arısoy, Arif; Topçu, Selim; Demirelli, Selami; Altunkaş, Fatih; Karayakalı, Metin; Çelik, Ataç; Tanboğa, İbrahim Halil; Aksakal, Enbiya; Sevimli, Serdar; Gürlertop, Hanefi Yekta

    2015-11-25

    The aim of this study was to evaluate right ventricle (RV) functions using echocardiography in healthy subjects who migrated from the sea level to moderate altitude (1890 m). The prospective observational in this study population consisted of 33 healthy subjects (23 men; mean age 20.4±3.2 years) who migrated from the sea level to a moderate altitude (Erzurum city centre, 1890 m above sea level) for long-term stay. Subjects underwent echocardiographic evaluation within the first 48 h of exposure to the moderate altitude and at the sixth month of arrival. Conventional echocardiographic parameters such as RV sizes and areas, systolic, and diastolic functional indices [fractional area change (FAC), tricuspid flow velocities, myocardial performance index (MPI), and tricuspid annular plane systolic excursion (TAPSE)] were obtained. Systolic (S) and diastolic (E', A') velocities were acquired from the apical fourchamber view using tissue Doppler imaging. Kolmogorov-Smirnov test, student's t-test, Wilcoxon test, and chi-square test were used in this study. There were no significant changes in RV size, FAC, MPI, TAPSE, inferior inspiratory vena cava collapse, tricuspid E velocity, and tricuspid annulus E' velocity. Compared with the baseline, there was a significant increase in mean pulmonary artery pressure (p=0.001); RV end systolic area (p=0.014); right atrial end diastolic area (p=0.021); tricuspid A velocity (p=0.013); tricuspid annulus S and A' velocity (p=0.031 and p=0.006, respectively); and RV free wall S, E', and A' velocity (p=0.007, pa significant decrease in tricuspid E/A ratio (1.61±0.3 vs. 1.45±0.2, p=0.038) and tricuspid annulus E'/A' ratio (1.52±0.5 vs. 1.23±0.4, p=0.002) at the sixth month. Our study revealed that right ventricular diastolic function was altered while the systolic function was preserved in healthy subjects who migrated from the sea level to a moderate altitude.

  13. Basic and advanced echocardiographic evaluation of myocardial dysfunction in sepsis and septic shock.

    Science.gov (United States)

    Vallabhajosyula, S; Pruthi, S; Shah, S; Wiley, B M; Mankad, S V; Jentzer, J C

    2018-01-01

    Sepsis continues to be a leading cause of mortality and morbidity in the intensive care unit. Cardiovascular dysfunction in sepsis is associated with worse short- and long-term outcomes. Sepsis-related myocardial dysfunction is noted in 20%-65% of these patients and manifests as isolated or combined left or right ventricular systolic or diastolic dysfunction. Echocardiography is the most commonly used modality for the diagnosis of sepsis-related myocardial dysfunction. With the increasing use of ultrasonography in the intensive care unit, there is a renewed interest in sepsis-related myocardial dysfunction. This review summarises the current scope of literature focused on sepsis-related myocardial dysfunction and highlights the use of basic and advanced echocardiographic techniques for the diagnosis of sepsis-related myocardial dysfunction and the management of sepsis and septic shock.

  14. Clinical and epidemiological profile of patients with valvular heart disease admitted to the emergency department

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Ricardo Casalino Sanches de [Instituto do Coração, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Katz, Marcelo [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Tarasoutchi, Flávio [Instituto do Coração, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil)

    2014-07-01

    To evaluate the clinical and epidemiological profile of patients with valvular heart disease who arrived decompensated at the emergency department of a university hospital in Brazil. A descriptive analysis of clinical and echocardiographic data of 174 patients with severe valvular disease, who were clinically decompensated and went to the emergency department of a tertiary cardiology hospital, in the State of São Paulo, in 2009. The mean age of participants was 56±17 years and 54% were female. The main cause of valve disease was rheumatic in 60%, followed by 15% of degenerative aortic disease and mitral valve prolapse in 13%. Mitral regurgitation (27.5%) was the most common isolated valve disease, followed by aortic stenosis (23%), aortic regurgitation (13%) and mitral stenosis (11%). In echocardiographic data, the mean left atrial diameter was 48±12mm, 38±12mm for the left ventricular systolic diameter, and 54±12mm for the diastolic diameter; the mean ejection fraction was 56±13%, and the mean pulmonary artery pressure was 53±16mmHg. Approximately half of patients (44%) presented atrial fibrillation, and over one third of them (37%) had already undergone another cardiac surgery. Despite increased comorbidities and age-dependent risk factors commonly described in patients with valvular heart disease, the clinical profile of patients arriving at the emergency department represented a cohort of rheumatic patients in more advanced stages of disease. These patients require priority care in high complexity specialized hospitals.

  15. Clinical and epidemiological profile of patients with valvular heart disease admitted to the emergency department

    International Nuclear Information System (INIS)

    Moraes, Ricardo Casalino Sanches de; Katz, Marcelo; Tarasoutchi, Flávio

    2014-01-01

    To evaluate the clinical and epidemiological profile of patients with valvular heart disease who arrived decompensated at the emergency department of a university hospital in Brazil. A descriptive analysis of clinical and echocardiographic data of 174 patients with severe valvular disease, who were clinically decompensated and went to the emergency department of a tertiary cardiology hospital, in the State of São Paulo, in 2009. The mean age of participants was 56±17 years and 54% were female. The main cause of valve disease was rheumatic in 60%, followed by 15% of degenerative aortic disease and mitral valve prolapse in 13%. Mitral regurgitation (27.5%) was the most common isolated valve disease, followed by aortic stenosis (23%), aortic regurgitation (13%) and mitral stenosis (11%). In echocardiographic data, the mean left atrial diameter was 48±12mm, 38±12mm for the left ventricular systolic diameter, and 54±12mm for the diastolic diameter; the mean ejection fraction was 56±13%, and the mean pulmonary artery pressure was 53±16mmHg. Approximately half of patients (44%) presented atrial fibrillation, and over one third of them (37%) had already undergone another cardiac surgery. Despite increased comorbidities and age-dependent risk factors commonly described in patients with valvular heart disease, the clinical profile of patients arriving at the emergency department represented a cohort of rheumatic patients in more advanced stages of disease. These patients require priority care in high complexity specialized hospitals

  16. Connecting clinical and actuarial prediction with rule-based methods

    NARCIS (Netherlands)

    Fokkema, M.; Smits, N.; Kelderman, H.; Penninx, B.W.J.H.

    2015-01-01

    Meta-analyses comparing the accuracy of clinical versus actuarial prediction have shown actuarial methods to outperform clinical methods, on average. However, actuarial methods are still not widely used in clinical practice, and there has been a call for the development of actuarial prediction

  17. Echocardiography derived three-dimensional printing of normal and abnormal mitral annuli

    Directory of Open Access Journals (Sweden)

    Feroze Mahmood

    2014-01-01

    Full Text Available Aims and Objectives: The objective of this study was to assess the clinical feasibility of using echocardiographic data to generate three-dimensional models of normal and pathologic mitral valve annuli before and after repair procedures. Materials and Methods: High-resolution transesophageal echocardiographic data from five patients was analyzed to delineate and track the mitral annulus (MA using Tom Tec Image-Arena software. Coordinates representing the annulus were imported into Solidworks software for constructing solid models. These solid models were converted to stereolithographic (STL file format and three-dimensionally printed by a commercially available Maker Bot Replicator 2 three-dimensional printer. Total time from image acquisition to printing was approximately 30 min. Results: Models created were highly reflective of known geometry, shape and size of normal and pathologic mitral annuli. Post-repair models also closely resembled shapes of the rings they were implanted with. Compared to echocardiographic images of annuli seen on a computer screen, physical models were able to convey clinical information more comprehensively, making them helpful in appreciating pathology, as well as post-repair changes. Conclusions: Three-dimensional printing of the MA is possible and clinically feasible using routinely obtained echocardiographic images. Given the short turn-around time and the lack of need for additional imaging, a technique we describe here has the potential for rapid integration into clinical practice to assist with surgical education, planning and decision-making.

  18. Echocardiographic and non-gated computed tomographic findings of intrapericardial tumor and mediastinal tumor adjacent to the heart

    International Nuclear Information System (INIS)

    Ueda, Minoru; Yamada, Nobuyuki; Saito, Daiji; Haraoka, Shoichi; Tanetani, Setsuro.

    1981-01-01

    Echocardiographic and computed tomographic findings of a case of intrapericardial tumor are reported, and two other cases of mediastinal tumor are presented in a discussion of the differential diagnosis of intrapericardial from mediastinal tumors. Case report: A 7-year-old male complained of cough and dyspnea. Cardiomegaly had been pointed out at a mass X-ray examination about a month prior to the admission. Two-dimensional echocardiography revealed a massive anterior pericardial effusion and a fist-sized tumor with cystic structure. The tumor pushed the heart backward at the level of the aortic root. Non-gated computed tomography of the chest disclosed the size and location of the tumor, but failed to clarify the internal structure. The patient underwent successful removal of a tumor, 12 x 10 x 8 cm in size and 350 g in weight, originating from the left atrial wall. Histologically, the tumor was a fibrosarcomatous mesothelioma. Usually, an intrapericardial tumor is easily suspected by echocardiography by the presence of pericardial effusion, although there have been a few reports of intrapericardial tumors without pericardial effusion. Echocardiographic diagnosis of the intrapericardial tumor is difficult in such cases. Identification of the pericardium is necessary to diagnose whether a tumor is intra- or extrapericardial. This identification, however, is not always easy by echocardiography when the ultrasonic beams become tangent to the pericardium. The pericardium between the tumor and the heart could not be identified by echocardiography in our two cases of mediastinal tumor. Computed tomography is helpful in diagnosing the size and location of a mediastinal tumor. (author)

  19. Audit of cardiac pathology detection using a criteria-based perioperative echocardiography service.

    Science.gov (United States)

    Faris, J G; Hartley, K; Fuller, C M; Langston, R B; Royse, C F; Veltman, M G

    2012-07-01

    Transthoracic echocardiography is often used to screen patients prior to non-cardiac surgery to detect conditions associated with perioperative haemodynamic compromise and to stratify risk. However, anaesthetists' use of echocardiography is quite variable. A consortium led by the American College of Cardiology Foundation has developed appropriate use criteria for echocardiography. At Joondalup Hospital in Western Australia, we have used these criteria to order echocardiographic studies in patients attending our anaesthetic pre-admission clinic. We undertook this audit to determine the incidence of significant echocardiographic findings using this approach. In a 22-month period, 606 transthoracic echocardiographic studies were performed. This represented 8.7% of clinic attendees and 1.7% of all surgical patients. In about two-thirds of the patients, the indication for echocardiography was identified on the basis of a telephone screening questionnaire. The most common indications were poor exercise tolerance (27.4%), ischaemic heart disease (20.9%) and cardiac murmurs (16.3%). Over 26% of patients studied had significant cardiac pathology (i.e. moderate or severe echocardiographic findings), most importantly moderate or severe aortic stenosis (8.6%), poor left ventricular function (7.1%), a regional wall motion abnormality (4.3%) or moderate or severe mitral regurgitation (4.1%). Using appropriate use criteria to guide ordering transthoracic echocardiography studies led to a high detection rate of clinically important cardiac pathology in our perioperative service.

  20. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  1. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  2. Predictive Performance of Echocardiographic Parameters for Cardiovascular Events Among Elderly Treated Hypertensive Patients.

    Science.gov (United States)

    Chowdhury, Enayet K; Jennings, Garry L R; Dewar, Elizabeth; Wing, Lindon M H; Reid, Christopher M

    2016-07-01

    Hypertension leads to cardiac structural and functional changes, commonly assessed by echocardiography. In this study, we assessed the predictive performance of different echocardiographic parameters including left ventricular hypertrophy (LVH) on future cardiovascular outcomes in elderly hypertensive patients without heart failure. Data from LVH substudy of the Second Australian National Blood Pressure trial were used. Echocardiograms were performed at entry into the study. Cardiovascular outcomes were identified over short term (median 4.2 years) and long term (median 10.9 years). LVH was defined using threshold values of LV mass (LVM) indexed to either body surface area (BSA) or height(2.7): >115/95g/m(2) (LVH-BSA(115/95)) or ≥49/45g/m(2.7) (LVH-ht(49/45)) in males/females, respectively, and ≥125g/m(2) (LVH-BSA(125)) or ≥51g/m(2.7) (LVH-ht(51)) for both sexes. In the 666 participants aged ≥65 years in this analysis, LVH prevalence at baseline was 33%-70% depending on definition; and after adjusting for potential risk factors, only LVH-BSA(115/95) predicted both short- and long-term cardiovascular outcomes. Participants having LVH-BSA(115/95) (69%) at baseline had twice the risk of having any first cardiovascular event over the short term (hazard ratio, 95% confidence interval: 2.00, 1.12-3.57, P = 0.02) and any fatal cardiovascular events (2.11, 1.21-3.68, P = 0.01) over the longer term. Among other echocardiographic parameters, LVM and LVM indexed to either BSA or height(2.7) predicted cardiovascular events over both short and longer term. In elderly treated hypertensive patients without heart failure, determining LVH by echocardiography is highly dependent on the methodology adopted. LVH-BSA(115/95) is a reliable predictor of future cardiovascular outcomes in the elderly. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Echocardiographic assessment of systolic pulmonary arterial pressure in HIV-positive patients.

    Directory of Open Access Journals (Sweden)

    Mehrnaz Rasoulinejad

    2014-11-01

    Full Text Available Pulmonary hypertension is rare but is one of the complications that occur due to HIV infection. Symptoms of HIV-associated pulmonary arterial hypertension are often non-specific but the main symptom of the disease is dyspnea. In this cross-sectional study, we measured systolic pulmonary arterial pressure (SPAP by echocardiographic methods among HIV-positive patients who received ART. This research is a descriptive, cross-sectional study of 170 HIV-positive patients that was conducted in Imam-Khomeini hospital, Tehran, Iran during 2011-2013. All patients regularly received antiretroviral therapy at least for recent 2 years. There were not any cardiopulmonary symptoms (cough, dyspnea, exertional fatigue and chest discomfort in these patients. All participants underwent echocardiography to estimate SPAP. The participants comprised 108 males (63.5% and 62 females (46.5%. The mean age of patients was 41 years old, and the mean duration of HIV infection was 5.5 years. The mean CD4 cell count was 401 cell/µl. The principal regimen of antiretroviral therapy included two nucleoside reverse transcriptase inhibitor (NRTI and one non-nucleoside reverse transcriptase inhibitor (NNRTI in the hospital. The mean of systolic pulmonary arterial pressure was 25 mmHg in the participants; 156 (93.4% of them had SPAP ≤ 30 mmHg (normal, six (3.6% had SPAP: 31-35 mmHg (borderline and five (3% had SPAP > 35 mmHg (pulmonary hypertension. Our results indicated a significant increase of pulmonary hypertension in asymptomatic HIV-positive patients that had no association with any other risk factor. Also, antiretroviral therapy was not a risk factor for pulmonary hypertension in this study.

  4. Prognostic implications of left ventricular mass and geometry following myocardial infarction: the VALIANT (VALsartan In Acute myocardial iNfarcTion) Echocardiographic Study.

    Science.gov (United States)

    Verma, Anil; Meris, Alessandra; Skali, Hicham; Ghali, Jalal K; Arnold, J Malcolm O; Bourgoun, Mikhail; Velazquez, Eric J; McMurray, John J V; Kober, Lars; Pfeffer, Marc A; Califf, Robert M; Solomon, Scott D

    2008-09-01

    This study sought to understand prognostic implications of increased baseline left ventricular (LV) mass and geometric patterns in a high risk acute myocardial infarction. The LV hypertrophy and alterations in LV geometry are associated with an increased risk of adverse cardiovascular events. Quantitative echocardiographic analyses were performed at baseline in 603 patients from the VALIANT (VALsartan In Acute myocardial iNfarcTion) echocardiographic study. The left ventricular mass index (LVMi) and relative wall thickness (RWT) were calculated. Patients were classified into 4 mutually exclusive groups based on RWT and LVMi as follows: normal geometry (normal LVMi and normal RWT), concentric remodeling (normal LVMi and increased RWT), eccentric hypertrophy (increased LVMi and normal RWT), and concentric hypertrophy (increased LVMi and increased RWT). Cox proportional hazards models were used to evaluate the relationships among LVMi, RWT, LV geometry, and clinical outcomes. Mean LVMi and RWT were 98.8 +/- 28.4 g/m(2) and 0.38 +/- 0.08. The risk of death or the composite end point of death from cardiovascular causes, reinfarction, heart failure, stroke, or resuscitation after cardiac arrest was lowest for patients with normal geometry, and increased with concentric remodeling (hazard ratio [HR]: 3.0; 95% confidence interval [CI]: 1.9 to 4.9), eccentric hypertrophy (HR: 3.1; 95% CI: 1.9 to 4.8), and concentric hypertrophy (HR: 5.4; 95% CI: 3.4 to 8.5), after adjusting for baseline covariates. Also, baseline LVMi and RWT were associated with increased mortality and nonfatal cardiovascular outcomes (HR: 1.22 per 10 g/m(2) increase in LVMi; 95% CI: 1.20 to 1.30; p independent of LVMi. Increased baseline LV mass and abnormal LV geometry portend an increased risk for morbidity and mortality following high-risk myocardial infarction. Concentric LV hypertrophy carries the greatest risk of adverse cardiovascular events including death. Higher RWT was associated with an

  5. FAST (Four chamber view And Swing Technique) Echo: a Novel and Simple Algorithm to Visualize Standard Fetal Echocardiographic Planes

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto; Jodicke, Cristiano; Oggè, Giovanna; Lee, Wesley; Kusanovic, Juan Pedro; Vaisbuch, Edi; Hassan, Sonia S.

    2010-01-01

    Objective To describe a novel and simple algorithm (FAST Echo: Four chamber view And Swing Technique) to visualize standard diagnostic planes of fetal echocardiography from dataset volumes obtained with spatiotemporal image correlation (STIC) and applying a new display technology (OmniView). Methods We developed an algorithm to image standard fetal echocardiographic planes by drawing four dissecting lines through the longitudinal view of the ductal arch contained in a STIC volume dataset. Three of the lines are locked to provide simultaneous visualization of targeted planes, and the fourth line (unlocked) “swings” through the ductal arch image (“swing technique”), providing an infinite number of cardiac planes in sequence. Each line generated the following plane(s): 1) Line 1: three-vessels and trachea view; 2) Line 2: five-chamber view and long axis view of the aorta (obtained by rotation of the five-chamber view on the y-axis); 3) Line 3: four-chamber view; and 4) “Swing” line: three-vessels and trachea view, five-chamber view and/or long axis view of the aorta, four-chamber view, and stomach. The algorithm was then tested in 50 normal hearts (15.3 – 40 weeks of gestation) and visualization rates for cardiac diagnostic planes were calculated. To determine if the algorithm could identify planes that departed from the normal images, we tested the algorithm in 5 cases with proven congenital heart defects. Results In normal cases, the FAST Echo algorithm (3 locked lines and rotation of the five-chamber view on the y-axis) was able to generate the intended planes (longitudinal view of the ductal arch, pulmonary artery, three-vessels and trachea view, five-chamber view, long axis view of the aorta, four-chamber view): 1) individually in 100% of cases [except for the three-vessel and trachea view, which was seen in 98% (49/50)]; and 2) simultaneously in 98% (49/50). The “swing technique” was able to generate the three-vessels and trachea view, five

  6. The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine.

    Science.gov (United States)

    Liu, Peng; Liu, Rijing; Zhang, Yan; Liu, Yingfeng; Tang, Xiaoming; Cheng, Yanzhen

    The objective of this study was to assess the clinical feasibility of generating 3D printing models of left atrial appendage (LAA) using real-time 3D transesophageal echocardiogram (TEE) data for preoperative reference of LAA occlusion. Percutaneous LAA occlusion can effectively prevent patients with atrial fibrillation from stroke. However, the anatomical structure of LAA is so complicated that adequate information of its structure is essential for successful LAA occlusion. Emerging 3D printing technology has the demonstrated potential to structure more accurately than conventional imaging modalities by creating tangible patient-specific models. Typically, 3D printing data sets are acquired from CT and MRI, which may involve intravenous contrast, sedation, and ionizing radiation. It has been reported that 3D models of LAA were successfully created by the data acquired from CT. However, 3D printing of the LAA using real-time 3D TEE data has not yet been explored. Acquisition of 3D transesophageal echocardiographic data from 8 patients with atrial fibrillation was performed using the Philips EPIQ7 ultrasound system. Raw echocardiographic image data were opened in Philips QLAB and converted to 'Cartesian DICOM' format and imported into Mimics® software to create 3D models of LAA, which were printed using a rubber-like material. The printed 3D models were then used for preoperative reference and procedural simulation in LAA occlusion. We successfully printed LAAs of 8 patients. Each LAA costs approximately CNY 800-1,000 and the total process takes 16-17 h. Seven of the 8 Watchman devices predicted by preprocedural 2D TEE images were of the same sizes as those placed in the real operation. Interestingly, 3D printing models were highly reflective of the shape and size of LAAs, and all device sizes predicted by the 3D printing model were fully consistent with those placed in the real operation. Also, the 3D printed model could predict operating difficulty and the

  7. Added clinical value of applying myocardial deformation imaging to assess right ventricular function.

    Science.gov (United States)

    Sokalskis, Vladislavs; Peluso, Diletta; Jagodzinski, Annika; Sinning, Christoph

    2017-06-01

    Right heart dysfunction has been found to be a strong prognostic factor predicting adverse outcome in various cardiopulmonary diseases. Conventional echocardiographic measurements can be limited by geometrical assumptions and impaired reproducibility. Speckle tracking-derived strain provides a robust quantification of right ventricular function. It explicitly evaluates myocardial deformation, as opposed to tissue Doppler-derived strain, which is computed from tissue velocity gradients. Right ventricular longitudinal strain provides a sensitive tool for detecting right ventricular dysfunction, even at subclinical levels. Moreover, the longitudinal strain can be applied for prognostic stratification of patients with pulmonary hypertension, pulmonary embolism, and congestive heart failure. Speckle tracking-derived right atrial strain, right ventricular longitudinal strain-derived mechanical dyssynchrony, and three-dimensional echocardiography-derived strain are emerging imaging parameters and methods. Their application in research is paving the way for their clinical use. © 2017, Wiley Periodicals, Inc.

  8. Clinical tooth preparations and associated measuring methods: a systematic review.

    Science.gov (United States)

    Tiu, Janine; Al-Amleh, Basil; Waddell, J Neil; Duncan, Warwick J

    2015-03-01

    The geometries of tooth preparations are important features that aid in the retention and resistance of cemented complete crowns. The clinically relevant values and the methods used to measure these are not clear. The purpose of this systematic review was to retrieve, organize, and critically appraise studies measuring clinical tooth preparation parameters, specifically the methodology used to measure the preparation geometry. A database search was performed in Scopus, PubMed, and ScienceDirect with an additional hand search on December 5, 2013. The articles were screened for inclusion and exclusion criteria and information regarding the total occlusal convergence (TOC) angle, margin design, and associated measuring methods were extracted. The values and associated measuring methods were tabulated. A total of 1006 publications were initially retrieved. After removing duplicates and filtering by using exclusion and inclusion criteria, 983 articles were excluded. Twenty-three articles reported clinical tooth preparation values. Twenty articles reported the TOC, 4 articles reported margin designs, 4 articles reported margin angles, and 3 articles reported the abutment height of preparations. A variety of methods were used to measure these parameters. TOC values seem to be the most important preparation parameter. Recommended TOC values have increased over the past 4 decades from an unachievable 2- to 5-degree taper to a more realistic 10 to 22 degrees. Recommended values are more likely to be achieved under experimental conditions if crown preparations are performed outside of the mouth. We recommend that a standardized measurement method based on the cross sections of crown preparations and standardized reporting be developed for future studies analyzing preparation geometry. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. [Doppler echocardiographic investigation of left ventricular diastolic function in preterm infants with and without a patent ductus arteriosus].

    Science.gov (United States)

    Schmitz, L; Stiller, B; Koehne, P; Koch, H; Lange, P E

    2004-01-01

    We studied the influence of preload augmentation on Doppler-derived left ventricular diastolic function parameters in infants with a birth weight ductus arteriosus a complete echocardiographic study including Doppler investigations of the mitral inflow signals and analysis of diastolic time intervals was performed. Neonates with an open duct had a lower median gestational age (27.1 vs. 29, Pductus peak early filling velocity (41.2 vs. 30.4 cm, Pventricular diastolic failure in extremely low birth weight infants in the presence of a preload challenge. The coincidence of higher peak velocities with a shortened isovolumic relaxation time is very likely a result of left atrial pressure elevation. Preload mismatch has to be considered in preterm infants with a persistent ductus arteriosus. The results of this study can be helpful to find the indication for PDA-closure and to adjust volume replacement therapy, and catecholamine medication to a level appropriate for the individual cardiac performance.

  10. Reliability Of A Novel Intracardiac Electrogram Method For AV And VV Delay Optimization And Comparability To Echocardiography Procedure For Determining Optimal Conduction Delays In CRT Patients

    Directory of Open Access Journals (Sweden)

    N Reinsch

    2009-03-01

    Full Text Available Background: Echocardiography is widely used to optimize CRT programming. A novel intracardiac electrogram method (IEGM was recently developed as an automated programmer-based method, designed to calculate optimal atrioventricular (AV and interventricular (VV delays and provide optimized delay values as an alternative to standard echocardiographic assessment.Objective: This study was aimed at determining the reliability of this new method. Furthermore the comparability of IEGM to existing echocardiographic parameters for determining optimal conduction delays was verified.Methods: Eleven patients (age 62.9± 8.7; 81% male; 73% ischemic, previously implanted with a cardiac resynchronisation therapy defibrillator (CRT-D underwent both echocardiographic and IEGM-based delay optimization.Results: Applying the IEGM method, concordance of three consecutively performed measurements was found in 3 (27% patients for AV delay and in 5 (45% patients for VV delay. Intra-individual variation between three measurements as assessed by the IEGM technique was up to 20 ms (AV: n=6; VV: n=4. E-wave, diastolic filling time and septal-to-lateral wall motion delay emerged as significantly different between the echo and IEGM optimization techniques (p < 0.05. The final AV delay setting was significantly different between both methods (echo: 126.4 ± 29.4 ms, IEGM: 183.6 ± 16.3 ms; p < 0.001; correlation: R = 0.573, p = 0.066. VV delay showed significant differences for optimized delays (echo: 46.4 ± 23.8 ms, IEGM: 10.9 ± 7.0 ms; p <0.01; correlation: R = -0.278, p = 0.407.Conclusion: The automated programmer-based IEGM-based method provides a simple and safe method to perform CRT optimization. However, the reliability of this method appears to be limited. Thus, it remains difficult for the examiner to determine the optimal hemodynamic settings. Additionally, as there was no correlation between the optimal AV- and VV-delays calculated by the IEGM method and the echo

  11. Jet length/velocity ratio: a new index for echocardiographic evaluation of chronic aortic regurgitation.

    Science.gov (United States)

    Güvenç, Tolga Sinan; Karaçimen, Denizhan; Erer, Hatice Betül; İlhan, Erkan; Sayar, Nurten; Karakuş, Gültekin; Çekirdekçi, Elif; Eren, Mehmet

    2015-01-01

    Management of aortic regurgitation depends on the assessment for severity. Echocardiography remains as the most widely available tool for evaluation of aortic regurgitation. In this manuscript, we describe a novel parameter, jet length/velocity ratio, for the diagnosis of severe aortic regurgitation. A total of 30 patients with aortic regurgitation were included to this study. Severity of aortic regurgitation was assessed with an aortic regurgitation index incorporating five echocardiographic parameters. Jet length/velocity ratio is calculated as the ratio of maximum jet penetrance to mean velocity of regurgitant flow. Jet length/velocity ratio was significantly higher in patients with severe aortic regurgitation (2.03 ± 0.53) compared to patients with less than severe aortic regurgitation (1.24 ± 0.32, P < 0.001). Correlation of jet length/velocity ratio with aortic regurgitation index was very good (r(2) = 0.86) and correlation coefficient was higher for jet length/velocity ratio compared to vena contracta, jet width/LVOT ratio and pressure half time. For a cutoff value of 1.61, jet length/velocity ratio had a sensitivity of 92% and specificity of 88%, with an AUC value of 0.955. Jet length/velocity ratio is a novel parameter that can be used to assess severity of chronic aortic regurgitation. Main limitation for usage of this novel parameter is jet impringement to left ventricular wall. © 2014, Wiley Periodicals, Inc.

  12. Dynamic three-dimensional display of common congenital cardiac defects from reconstruction of two-dimensional echocardiographic images.

    Science.gov (United States)

    Hsieh, K S; Lin, C C; Liu, W S; Chen, F L

    1996-01-01

    Two-dimensional echocardiography had long been a standard diagnostic modality for congenital heart disease. Further attempts of three-dimensional reconstruction using two-dimensional echocardiographic images to visualize stereotypic structure of cardiac lesions have been successful only recently. So far only very few studies have been done to display three-dimensional anatomy of the heart through two-dimensional image acquisition because such complex procedures were involved. This study introduced a recently developed image acquisition and processing system for dynamic three-dimensional visualization of various congenital cardiac lesions. From December 1994 to April 1995, 35 cases were selected in the Echo Laboratory here from about 3000 Echo examinations completed. Each image was acquired on-line with specially designed high resolution image grazmber with EKG and respiratory gating technique. Off-line image processing using a window-architectured interactive software package includes construction of 2-D ehcocardiographic pixel to 3-D "voxel" with conversion of orthogonal to rotatory axial system, interpolation, extraction of region of interest, segmentation, shading and, finally, 3D rendering. Three-dimensional anatomy of various congenital cardiac defects was shown, including four cases with ventricular septal defects, two cases with atrial septal defects, and two cases with aortic stenosis. Dynamic reconstruction of a "beating heart" is recorded as vedio tape with video interface. The potential application of 3D display of the reconstruction from 2D echocardiographic images for the diagnosis of various congenital heart defects has been shown. The 3D display was able to improve the diagnostic ability of echocardiography, and clear-cut display of the various congenital cardiac defects and vavular stenosis could be demonstrated. Reinforcement of current techniques will expand future application of 3D display of conventional 2D images.

  13. The Doppler echocardiographic myocardial performance index predicts left-ventricular dilation and cardiac death after myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To investigate the value of the Doppler-derived myocardial performance index to predict early left-ventricular (LV) dilation and cardiac death after a first acute myocardial infarction (AMI), Doppler echocardiography was performed within 24 h of hospital admission, on day 5, 1 and 3 months after...... AMI in 125 consecutive patients. The index measured on day 1 correlated well with the change in end-diastolic volume index observed from day 1 to 3 months following AMI (r = 0.66, p 0.0001). One-year survival in patients with Doppler index index > or = 0......, we conclude that the Doppler echocardiographic myocardial performance index is a predictor of LV dilation and cardiac death after a first AMI....

  14. Echocardiographic impact of hydration status in dialysis patients.

    Science.gov (United States)

    Juan-García, Isabel; Puchades, María J; Sanjuán, Rafael; Torregrosa, Isidro; Solís, Miguel Á; González, Miguel; Blasco, Marisa; Martínez, Antonio; Miguel, Alfonso

    2012-01-01

    Cardiovascular disease is the main cause of death in Chronic Kidney Disease patients. Left ventricular hypertrophy is the most common manifestation and it is linked to arterial hypertension and overhydration. The goal of this paper is to stratify dialyzed patients according to hydration status and to make an evaluation about the possible echocardiography alterations of the different groups. A transversal study was carried out with 117 patients: 65 were on hemodialysis and 52 on peritoneal dialysis. We performed the following tests: multifrequency bioimpedance with the BCM-Body Composition Freesenius’ Monitor system, transthoracic echocardiography, and blood tests. If ECW/TBW (extracellular water vs total body water) normalization ratio for age and gender was > 2.5% SD, the patient was considered overhydrated. HD patients are significantly overhydrated before HD (67.1%) compared to DP patients (46.1%), and almost half of the overhydrated population presents arterial hypertension. However, after an HD session, a better control of the hydration status is reached (26.1%). DP patients frequently present high arterial pressure and/or are under antihypertensive treatment (DP 76.9% vs HD 49.2%). Left ventricular hypertrophy is much more common in HD overhydrated patients, eccentric LVH being more prevalent. Overhydrated patients present significantly high values of LAVI, ILVM, OH/ECW. Bioimpedance technique allows for the detection of a large number of overhydrated patients. Echocardiographic alterations in dialyzed patients show a high correlation between the hydration stage by ECW/TBW normalized ratio for age and gender and the LAVI and ILVM.

  15. Left ventricular fluid dynamics in heart failure: echocardiographic measurement and utilities of vortex formation time.

    Science.gov (United States)

    Poh, Kian Keong; Lee, Li Ching; Shen, Liang; Chong, Eric; Tan, Yee Leng; Chai, Ping; Yeo, Tiong Cheng; Wood, Malissa J

    2012-05-01

    In clinical heart failure (HF), inefficient propagation of blood through the left ventricle (LV) may result from suboptimal vortex formation (VF) ability of the LV during early diastole. We aim to (i) validate echocardiographic-derived vortex formation time (adapted) (VFTa) in control subjects and (ii) examine its utility in both systolic and diastolic HF. Transthoracic echocardiography was performed in 32 normal subjects and in 130 patients who were hospitalized with HF [91, reduced ejection fraction (rEF) and 39, preserved ejection fraction (pEF)]. In addition to biplane left ventricular ejection fraction (LVEF) and conventional parameters, the Tei index and tissue Doppler (TD) indices were measured. VFTa was obtained using the formula: 4 × (1 - β)/π × α³ × LVEF, where β is the fraction of total transmitral diastolic stroke volume contributed by atrial contraction (assessed by time velocity integral of the mitral E- and A-waves) and α is the biplane end-diastolic volume (EDV)(1/3) divided by mitral annular diameter during early diastole. VFTa was correlated with demographic, cardiac parameters, and a composite clinical endpoint comprising cardiac death and repeat hospitalization for HF. Mean VFTa was 2.67 ± 0.8 in control subjects; reduced in HF, preserved EF HF, 2.21 ± 0.8; HF with reduced EF, 1.25 ± 0.6 (PTD early diastolic myocardial velocities (E', septal, r = 0.46; lateral, r = 0.43), systolic myocardial velocities (S', septal, r = 0.47; lateral, r = 0.41), and inversely with the Tei index (r = -0.41); all Ps < 0.001. Sixty-two HF patients (49%) met the composite endpoint. VFTa of <1.32 was associated with significantly reduced event-free survival (Kaplan Meier log rank = 16.3, P= 0.0001) and predicted the endpoint with a sensitivity and specificity of 65 and 72%, respectively. VFTa, a dimensionless index, incorporating LV geometry, systolic and diastolic parameters, may be useful in the diagnosis and prognosis of HF.

  16. A study of active learning methods for named entity recognition in clinical text.

    Science.gov (United States)

    Chen, Yukun; Lasko, Thomas A; Mei, Qiaozhu; Denny, Joshua C; Xu, Hua

    2015-12-01

    Named entity recognition (NER), a sequential labeling task, is one of the fundamental tasks for building clinical natural language processing (NLP) systems. Machine learning (ML) based approaches can achieve good performance, but they often require large amounts of annotated samples, which are expensive to build due to the requirement of domain experts in annotation. Active learning (AL), a sample selection approach integrated with supervised ML, aims to minimize the annotation cost while maximizing the performance of ML-based models. In this study, our goal was to develop and evaluate both existing and new AL methods for a clinical NER task to identify concepts of medical problems, treatments, and lab tests from the clinical notes. Using the annotated NER corpus from the 2010 i2b2/VA NLP challenge that contained 349 clinical documents with 20,423 unique sentences, we simulated AL experiments using a number of existing and novel algorithms in three different categories including uncertainty-based, diversity-based, and baseline sampling strategies. They were compared with the passive learning that uses random sampling. Learning curves that plot performance of the NER model against the estimated annotation cost (based on number of sentences or words in the training set) were generated to evaluate different active learning and the passive learning methods and the area under the learning curve (ALC) score was computed. Based on the learning curves of F-measure vs. number of sentences, uncertainty sampling algorithms outperformed all other methods in ALC. Most diversity-based methods also performed better than random sampling in ALC. To achieve an F-measure of 0.80, the best method based on uncertainty sampling could save 66% annotations in sentences, as compared to random sampling. For the learning curves of F-measure vs. number of words, uncertainty sampling methods again outperformed all other methods in ALC. To achieve 0.80 in F-measure, in comparison to random

  17. Echocardiographic Evidence of Early Diastolic Dysfunction in Asymptomatic Children with Osteogenesis Imperfecta

    Directory of Open Access Journals (Sweden)

    Khalfan S. Al-Senaidi

    2015-11-01

    Full Text Available Objectives: Structural and functional cardiovascular abnormalities have been reported in adults with osteogenesis imperfecta (OI; however, there is a lack of paediatric literature on this topic. This study aimed to investigate cardiovascular abnormalities in children with OI in comparison to a control group. Methods: This case-control study was conducted at the Sultan Qaboos University Hospital in Muscat, Oman, between May 2013 and August 2014. Data from eight patients with OI and 24 healthy controls were compared using conventional and tissue Doppler echocardiography (TDE. Results: The OI group had significantly lower peak early mitral valve flow velocity (P = 0.027, peak a-wave reversal in the pulmonary vein (P = 0.030 and peak early diastolic velocity of the mitral valve and upper septum (P = 0.001 each. The peak late diastolic velocities of the mitral valve (P = 0.002 and the upper septum (P = 0.037 were significantly higher in the OI group; however, the peak early/late diastolic velocity ratios of the mitral valve (P = 0.002 and upper septum (P = 0.001 were significantly lower. Left ventricular dimensions and aortic and pulmonary artery diameters were larger in the OI group when indexed for body surface area. Both groups had normal systolic cardiac function. Conclusion: Children with OI had normal systolic cardiac function. However, changes in myocardial tissue Doppler velocities were suggestive of early diastolic cardiac dysfunction. They also had increased left ventricular dimensions and greater vessel diameters. These findings indicate the need for early and detailed structural and functional echocardiographic assessment and follow-up of young patients with OI.

  18. Prevalence, clinical and echocardiographic characteristics of various flow and gradient patterns in mild or moderate aortic stenosis with normal left ventricular ejection fraction.

    Science.gov (United States)

    Tan, Yong-Qiang Benjamin; Ngiam, Jinghao Nicholas; Kong, William K F; Yeo, Tiong-Cheng; Poh, Kian-Keong

    2016-10-15

    Paradoxical low-flow aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) has only been described in severe AS. Controversy surrounds prognosis and management but no studies have reported this phenomenon in mild or moderate AS. We investigated the prevalence of flow and gradient patterns in this population, characterising their clinical and echocardiographic profile. Consecutive subjects (n=1362) with isolated AS: mild (n=462, aortic valve area≥1.5cm(2), 2.5m/sa third of the cases. These patients had different LV structure compared to normal-flow, with more concentric remodelling. Further studies are warranted. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Echocardiographic Evaluation of Hemodynamic Changes in Left-Sided Heart Valves in Pregnant Women With Valvular Heart Disease.

    Science.gov (United States)

    Samiei, Niloufar; Amirsardari, Mandana; Rezaei, Yousef; Parsaee, Mozhgan; Kashfi, Fahimeh; Hantoosh Zadeh, Sedigheh; Beikmohamadi, Somayeh; Fouladi, Masoumeh; Hosseini, Saeid; Peighambari, Mohammad Mehdi; Mohebbi, Ahmad

    2016-10-01

    Physiologic changes during pregnancy can deteriorate or improve patients' hemodynamic status in the setting of valvular heart disease. There are sparse data regarding the effect of pregnancy on valve hemodynamics in normal pregnant women with known valvular heart disease. In a prospective study from July 2014 to January 2016, a total of 52 normal pregnant women who had mitral stenosis, aortic stenosis, or a history of mitral valve or aortic valve replacements were assessed. All patients underwent echocardiographic examinations and hemodynamic parameters were measured for both the mitral valve and aortic valve at first, second, and third trimesters. The parameters included mean gradient, peak gradient, mean gradient/heart rate, peak gradient/heart rate, pressure halftime, dimensionless velocity index, and valve area. Although most hemodynamic parameters (i.e., mean gradient, peak gradient, mean gradient/heart rate, and peak gradient/heart rate) increased approximately 50% from first to second trimester and first to third trimester (p 0.05). The ratio of changes between trimesters for valve area and dimensionless velocity index were comparable. No clinical decompensations were observed except for 3 and 7 cases of deterioration to functional class II at second and third trimesters, respectively. In conclusion, during a full-term and uncomplicated pregnancy, mitral and aortic valve gradients increase without significant changes in valve area that are more marked between the second and first trimester than between the third and second trimester. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Dynamic 3D echocardiography in virtual reality

    Directory of Open Access Journals (Sweden)

    Simoons Maarten L

    2005-12-01

    Full Text Available Abstract Background This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. Methods Three-dimensional echocardiographic data sets from 2 normal subjects and from 4 patients with a mitral valve pathological condition were included in the study. The three-dimensional data sets were acquired with the Philips Sonos 7500 echo-system and transferred to the BARCO (Barco N.V., Kortrijk, Belgium I-space. Ten independent observers assessed the 6 three-dimensional data sets with and without mitral valve pathology. After 10 minutes' instruction in the I-Space, all of the observers could use the virtual pointer that is necessary to create cut planes in the hologram. Results The 10 independent observers correctly assessed the normal and pathological mitral valve in the holograms (analysis time approximately 10 minutes. Conclusion this report shows that dynamic holographic imaging of three-dimensional echocardiographic data is feasible. However, the applicability and use-fullness of this technology in clinical practice is still limited.

  1. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  2. Evaluation of left ventricular function by invasive and noninvasive methods

    Energy Technology Data Exchange (ETDEWEB)

    Kusukawa, R [Yamaguchi Univ., Ube (Japan). School of Medicine

    1982-06-01

    Noninvasive methods in cardiology have progressed very rapidly in recent years. Cardiac catheterization and angiocardiography are the standard methods for evaluating of cardiac performance, however, they need expensive apparatus and are time-consuming, arduous procedures which do not permit to repeat frequently, and sometimes risky. In this article, the indices of pump and muscle function of the heart obtained by invasive methods were compared to those indices obtained by noninvasive methods, and correlation between two groups and usefulness and limitation were discussed. Systolic time intervals are convenient and repeatable measures of left ventricular performance in clinical cardiology. There are significant correlations of PEP/LVET with stroke volume, ejection fraction and mean circumferential shortening velocity. Although some limitations are present in application of this method to certain diseases, these measures are useful in the evaluation of left ventricular performance. Echocardiography has made an era of the noninvasive cardiology. Left ventricular volume, ejection fraction, mean circumferential shortening velocity and PSP/ESVI are accurately calculated by echocardiographic measurement. Nuclear cardiology is also accurate noninvasive method in evaluation of cardiac performance. With this tremendous growth in this field, it will make next era of noninvasive cardiology.

  3. The effect of 6-week high intensity interval training on the VEGF/COL-18 ratio and some echocardiographic indices in rats with myocardial infarction

    Directory of Open Access Journals (Sweden)

    Sara Karbalaeifar

    2016-12-01

    Full Text Available Introduction: Myocardial infarction (MI is the irreversible cell death caused by ischemia in parts of myocardium. The molecular process of increased capillary density in response to activity and its appropriate intensity is not clear yet. Therefore, this research aimed to evaluate the effect of 6-week high intensity interval training on the VEGF/COL-18 ratio and echocardiographic indices in rats with MI. Methods: Twelve Wistar male rats of 10 weeks old and mean weight 250-300gr were allocated to two groups of experimental (60 minutes of interval treadmill running for four minutes with the intensity of 85-90 and two minutes of active rest at 50-60 percent of VO2max for four days a week for 6 weeks and control group (without any training. Real-time PCR was used to assess the expression of VEGF and COL-18 genes after inducing MI, and shortening fractional and ejection fraction were investigated as echocardiographic indices. Data were analyzed in SPSS18 using independent t test (α≤ 0.05. Results: The findings showed that there was no significant increase in the VEGF/COL-18 ratio in the HIIT group (1.856 mg/ml as compared with the control group (1.245 mg/ml (p=0.263. A significant increase was observed in the HIIT group for SF (77.461±7.022% and EF (41.625±6.847% as compared with the control group (64.483±3.695% and (31.320±3.460%, respectively (p=0.001. Conclusion: In general, 6 weeks of high intensity interval training can effectively increase angiogenesis factors and improve myocardial function in male Wistar rats after MI.

  4. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy.

    Science.gov (United States)

    Khan, Sitara G; Klettas, Dimitris; Kapetanakis, Stam; Monaghan, Mark J

    2016-03-01

    Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain) has conventionally been assessed using tissue Doppler imaging (TDI), which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference ('speckles') in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT. © 2016 The authors.

  5. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy

    Directory of Open Access Journals (Sweden)

    Sitara G Khan

    2016-05-01

    Full Text Available Cardiac resynchronisation therapy (CRT can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain has conventionally been assessed using tissue Doppler imaging (TDI, which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference (‘speckles’ in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT.

  6. A comparison of cosegregation analysis methods for the clinical setting.

    Science.gov (United States)

    Rañola, John Michael O; Liu, Quanhui; Rosenthal, Elisabeth A; Shirts, Brian H

    2018-04-01

    Quantitative cosegregation analysis can help evaluate the pathogenicity of genetic variants. However, genetics professionals without statistical training often use simple methods, reporting only qualitative findings. We evaluate the potential utility of quantitative cosegregation in the clinical setting by comparing three methods. One thousand pedigrees each were simulated for benign and pathogenic variants in BRCA1 and MLH1 using United States historical demographic data to produce pedigrees similar to those seen in the clinic. These pedigrees were analyzed using two robust methods, full likelihood Bayes factors (FLB) and cosegregation likelihood ratios (CSLR), and a simpler method, counting meioses. Both FLB and CSLR outperform counting meioses when dealing with pathogenic variants, though counting meioses is not far behind. For benign variants, FLB and CSLR greatly outperform as counting meioses is unable to generate evidence for benign variants. Comparing FLB and CSLR, we find that the two methods perform similarly, indicating that quantitative results from either of these methods could be combined in multifactorial calculations. Combining quantitative information will be important as isolated use of cosegregation in single families will yield classification for less than 1% of variants. To encourage wider use of robust cosegregation analysis, we present a website ( http://www.analyze.myvariant.org ) which implements the CSLR, FLB, and Counting Meioses methods for ATM, BRCA1, BRCA2, CHEK2, MEN1, MLH1, MSH2, MSH6, and PMS2. We also present an R package, CoSeg, which performs the CSLR analysis on any gene with user supplied parameters. Future variant classification guidelines should allow nuanced inclusion of cosegregation evidence against pathogenicity.

  7. [Predictive methods versus clinical titration for the initiation of lithium therapy. A systematic review].

    Science.gov (United States)

    Geeraerts, I; Sienaert, P

    2013-01-01

    When lithium is administered, the clinician needs to know when the lithium in the patient’s blood has reached a therapeutic level. At the initiation of treatment the level is usually achieved gradually through the application of the titration method. In order to increase the efficacy of this procedure several methods for dosing lithium and for predicting lithium levels have been developed. To conduct a systematic review of the publications relating to the various methods for dosing lithium or predicting lithium levels at the initiation of therapy. We searched Medline systematically for articles published in English, French or Dutch between 1966 and April 2012 which described or studied a method for dosing lithium or for predicting the lithium level reached following a specific dosage. We screened the reference lists of relevant articles in order to locate additional papers. We found 38 lithium prediction methods, in addition to the clinical titration method. These methods can be divided into two categories: the ‘a priori’ methods and the ‘test-dose’ methods, the latter requiring the administration of a test dose of lithium. The lithium prediction methods generally achieve a therapeutic blood level faster than the clinical titration method, but none of the methods achieves convincing results. On the basis of our review, we propose that the titration method should be used as the standard method in clinical practice.

  8. Echocardiography Practice: Insights into Appropriate Clinical Use, Technical Competence and Quality Improvement Program

    Science.gov (United States)

    Kossaify, Antoine; Grollier, Gilles

    2014-01-01

    Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342

  9. A review of methods of clinical image quality evaluation in mammography

    International Nuclear Information System (INIS)

    Li Yanpeng; Poulos, Ann; McLean, Donald; Rickard, Mary

    2010-01-01

    Purpose: Consistency in evaluation of mammography images in research and clinical practice is dependent on a standardised clinical image quality evaluation system. Currently two such systems are available-one developed by the American College of Radiology (ACR) and the other by the European Commission (EU guidelines). The purpose of this study was to review mammography clinical evaluation methods in research studies and their adherence to these systems. Method: A total of 23 research articles were reviewed from the period 2000-2006, 11 of these studies used digital images. The focus of the review was the criteria and rating scales used. Results: Only 5 studies used either the ACR (3) or EU guidelines (2). The remainder included aspects of these systems together with a range of other criteria and rating scales. Variation was found in the categories of criteria used, number of criteria, the descriptors of the criteria and the instructions used to evaluate the criteria. Instructions were frequently not specific and open to individual interpretation. Although breast density is an important criterion of image quality and contributes to perception of breast lesions, inclusion of this criterion was not universal, and even when used the area of breast density to be evaluated was not identified, thus enhancing inter-observer variability. Scales that were absolute or relative were used for evaluation, all of which incorporated inconsistent numbers of steps. Conclusion: Low adherence to ACR and EU Guidelines has resulted in considerable variation in the evaluation methods used in research studies. The implications of this variability are considerable both for evaluation of image quality in research outcomes and clinical practice.

  10. Action research as a method for changing patient education practice in a clinical diabetes setting

    DEFF Research Database (Denmark)

    Voigt, Jane Rohde; Hansen, Ulla M.; Glindorf, Mette

    2014-01-01

    with researchers developed and implemented a participatory, group-based diabetes education program in a diabetes clinic in the Danish health care system. The research process included a variety of qualitative methods: workshops, classroom observations, video recordings and semi-structured interviews. These methods......Action research is potentially a useful method for changing clinical practice by involving practitioners in the process of change. The aim of this study was to explore the utility of action research in bridging the gap between research and practice. Diabetes educators in collaboration...... aimed at obtaining contextual sensitivity, allowing dynamic interactions with educators and people with diabetes. Despite challenges, the study demonstrates how action research methods contribute to development and change of diabetes education practice while simultaneously adding knowledge to the action...

  11. The analysis of verbal interaction sequences in dyadic clinical communication: a review of methods.

    Science.gov (United States)

    Connor, Martin; Fletcher, Ian; Salmon, Peter

    2009-05-01

    To identify methods available for sequential analysis of dyadic verbal clinical communication and to review their methodological and conceptual differences. Critical review, based on literature describing sequential analyses of clinical and other relevant social interaction. Dominant approaches are based on analysis of communication according to its precise position in the series of utterances that constitute event-coded dialogue. For practical reasons, methods focus on very short-term processes, typically the influence of one party's speech on what the other says next. Studies of longer-term influences are rare. Some analyses have statistical limitations, particularly in disregarding heterogeneity between consultations, patients or practitioners. Additional techniques, including ones that can use information about timing and duration of speech from interval-coding are becoming available. There is a danger that constraints of commonly used methods shape research questions and divert researchers from potentially important communication processes including ones that operate over a longer-term than one or two speech turns. Given that no one method can model the complexity of clinical communication, multiple methods, both quantitative and qualitative, are necessary. Broadening the range of methods will allow the current emphasis on exploratory studies to be balanced by tests of hypotheses about clinically important communication processes.

  12. The Burden of Pulmonary Hypertension in Patients with Degenerative Mitral Valve Disease in Enugu South-East Nigeria: An Echocardiographic Based Study.

    Science.gov (United States)

    Ejim, E C; Oguanobi, N I

    2016-01-01

    Pulmonary hypertension is a common complication of degenerative mitral valve disease, and contributes significantly to both morbidity and mortality. The use of medications for reduction of pulmonary pressure in patients is not a common practice by most physicians in this part of the world because of the absence of data on pulmonary hypertension. The authors set out to find the prevalence of pulmonary hypertension in patients with degenerative mitral valve disease and to determine if there are gender differences in affectation. This will form a basis for future research on the management of pulmonary hypertension in sub-Saharan Africa. The echocardiographic records of 1390 patients carried out over a period of 4 years were retrospectively reviewed. The examinations were done with a Logic 500 MD echocardiographic machine. Tricuspid valve regurgitation velocity above 250 cm/s defined pulmonary hypertension. Data obtained included presence of degenerative mitral valve disease, pulmonary hypertension, age, and gender. A total of 1390 echocardiogram reports done at Conquest Medical Imaging, Enugu, from July 2009 to August 2013 were retrospectively reviewed. Degenerative mitral valve disease was noted in 18.7% of the patients, (259/1390) made up of 149 males and 110 females with a mean age of 68.3 (14.4) years. Pulmonary hypertension was present in 30% of the patients (78/259) and affected males more than females. Pulmonary hypertension is common in patients with degenerative mitral valve disease in Enugu, and affects males more than females.

  13. Connecting clinical and actuarial prediction with rule-based methods.

    Science.gov (United States)

    Fokkema, Marjolein; Smits, Niels; Kelderman, Henk; Penninx, Brenda W J H

    2015-06-01

    Meta-analyses comparing the accuracy of clinical versus actuarial prediction have shown actuarial methods to outperform clinical methods, on average. However, actuarial methods are still not widely used in clinical practice, and there has been a call for the development of actuarial prediction methods for clinical practice. We argue that rule-based methods may be more useful than the linear main effect models usually employed in prediction studies, from a data and decision analytic as well as a practical perspective. In addition, decision rules derived with rule-based methods can be represented as fast and frugal trees, which, unlike main effects models, can be used in a sequential fashion, reducing the number of cues that have to be evaluated before making a prediction. We illustrate the usability of rule-based methods by applying RuleFit, an algorithm for deriving decision rules for classification and regression problems, to a dataset on prediction of the course of depressive and anxiety disorders from Penninx et al. (2011). The RuleFit algorithm provided a model consisting of 2 simple decision rules, requiring evaluation of only 2 to 4 cues. Predictive accuracy of the 2-rule model was very similar to that of a logistic regression model incorporating 20 predictor variables, originally applied to the dataset. In addition, the 2-rule model required, on average, evaluation of only 3 cues. Therefore, the RuleFit algorithm appears to be a promising method for creating decision tools that are less time consuming and easier to apply in psychological practice, and with accuracy comparable to traditional actuarial methods. (c) 2015 APA, all rights reserved).

  14. [Application of Delphi method in traditional Chinese medicine clinical research].

    Science.gov (United States)

    Bi, Ying-fei; Mao, Jing-yuan

    2012-03-01

    In recent years, Delphi method has been widely applied in traditional Chinese medicine (TCM) clinical research. This article analyzed the present application situation of Delphi method in TCM clinical research, and discussed some problems presented in the choice of evaluation method, classification of observation indexes and selection of survey items. On the basis of present application of Delphi method, the author analyzed the method on questionnaire making, selection of experts, evaluation of observation indexes and selection of survey items. Furthermore, the author summarized the steps of application of Delphi method in TCM clinical research.

  15. Clinical outcomes for young people with screening-detected and clinically-diagnosed rheumatic heart disease in Fiji.

    Science.gov (United States)

    Engelman, Daniel; Mataika, Reapi L; Ah Kee, Maureen; Donath, Susan; Parks, Tom; Colquhoun, Samantha M; Carapetis, Jonathan R; Kado, Joseph H; Steer, Andrew C

    2017-08-01

    Echocardiographic screening is under consideration as a disease control strategy for rheumatic heart disease (RHD). However, clinical outcomes of young people with screening-detected RHD are unknown. We aimed to describe the outcomes for a cohort with screening-detected RHD, in comparison to patients with clinically-diagnosed RHD. A retrospective cohort study included all young people with screening-detected RHD in the Central Division of Fiji in the primary cohort. Screen-negative and clinically-diagnosed comparison groups were matched 1:1 to the primary cohort. Data were collected on mortality, clinical complications and healthcare utilisation from the electronic and paper health records and existing databases. Seventy participants were included in each group. Demographic characteristics of the groups were similar (median age 11years, 69% female, median follow-up 7years). There were nine (12.9%) RHD-related deaths in the clinically-diagnosed group and one (1.4%) in the screening-detected group (Incident Rate Ratio: 9.6, 95% CI 1.3-420.6). Complications of RHD were observed in 39 (55.7%) clinically-diagnosed cases, four (20%) screening-detected cases and one (1.4%) screen-negative case. There were significant differences in the cumulative complication curves of the groups (pFiji. The prognosis of clinically-diagnosed RHD remains poor, with very high mortality and complication rates. Further studies in other settings will inform RHD screening policy. Comprehensive control strategies are required for disease prevention. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Does the routine echocardiographic exam have a role in the detection and evaluation of cholelithiasis and gallbladder wall thickening?

    Science.gov (United States)

    Daly, David D; El-Shurafa, Haytham; Nanda, Navin C; Dumaswala, Bhavin; Dumaswala, Komal; Kumar, Nilay; Mutluer, Ferit Onur

    2012-09-01

    Cholelithiasis is a very common disease in the United States. Most cases remain asymptomatic but a fraction of these patients can develop serious complications such as cholecystitis which may lead to gallbladder perforation and gallbladder cancer which is much less common. Here, we present three cases of cholelithiasis where transthoracic echocardiography was performed routinely. In each case, echocardiography detected cholelithiasis which prompted three-dimensional (3D) echocardiographic evaluation. Three-dimensional echocardiography allowed for more comprehensive examination of the gallbladder shape, size, and wall thickening and the measurement and composition of the stones in three dimensions, measurement of stone volumes, and minimized shadowing produced by stone calcifications. These cases suggest that routine echocardiography has value in detecting gallstones and that 3D echocardiography has incremental value over two-dimensional echocardiography due to pyramidal data sets which allow sequential slicing through the gallbladder and full gallbladder examination without a technologist who is trained in gallbladder imaging. These pyramidal data sets can be further viewed and cropped by a radiologist specialized in abdominal ultrasound. © 2012, Wiley Periodicals, Inc.

  17. On-Orbit Prospective Echocardiography on International Space Station Crew

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David S.; Garcia, Kathleen M.; Melton, Shannon L.; Feiveson, Alan; Dulchavsky, Scott A.

    2010-01-01

    Introduction A prospective trial of echocardiography was conducted on of six crewmembers onboard the International Space Station. The main objective was to determine the efficacy of remotely guided tele-echocardiography, including just-in-time e-training methods and determine what "space normal" echocardiographic data is. Methods Each crewmember operator (n=6) had 2-hour preflight training. Baseline echocardiographic data were collected 55 to 167days preflight. Similar equipment was used in each 60-minute in-flight session (mean microgravity exposure - 114 days (34 -- 190)). On Orbit ultrasound operators used an e-learning system within 24h of these sessions. Expert assistance was provided using ultrasound video downlink and two-way voice. Testing was repeated 5 to 16 days after landing. Separate ANOVA was used on each echocardiographic variable (n=33). Within each ANOVA, three tests were made: a) effect of mission phase (preflight, in-flight, post flight); b) effect of echo technician (two technicians independently analyzed the data); c) interaction between mission phase and technician. Results Nine rejections of the null hypothesis (mission phase or technician or both had no effect) were discovered and considered for follow up. Of these, six rejections were for significant technician effects, not as a result of space flight. Three rejections of the null hypothesis (Aortic Valve time velocity integral, Mitral E wave Velocity and heart rate) were attributable to space flight, however determined not to be clinically significant. No rejections were due to the interaction between technician and space flight. Conclusion No consistent clinically significant effects of long-duration space flight were seen in echocardiographic variables of the given group of subjects.

  18. Caudal venous return through a left azygos vein in a dog

    International Nuclear Information System (INIS)

    Sammarco, C.D.; Regan, J.; Ward, C.R.; Buchanan, J.D.

    1995-01-01

    The Clinical, radiologic and echocardiographic findings in a one-year old dog with mild subvalvular aortic stenosis and aberrant caudal vena circulation are described. Aberrant systemic venous return to the right side of the heart usually has little clinical significance, but the unusual features in survey radiographs, contrast angiograms and contrast echocardiograms constitute the reasons for this report

  19. [Assessment of the right ventricular anatomy and function by advanced echocardiography: pathological and physiological insights].

    Science.gov (United States)

    Lakatos, Bálint; Kovács, Attila; Tokodi, Márton; Doronina, Alexandra; Merkely, Béla

    2016-07-01

    Accurate assessment of right ventricular geometry and function is of high clinical importance. However, several limitations have to be taken into consideration if using conventional echocardiographic parameters. Advanced echocardiographic techniques, such as speckle-tracking analysis or 3D echocardiography are reliable and simple tools providing a cost-effective and non-invasive alternative of current modalities used to characterize the right ventricle. There is a growing interest in the diagnostic and prognostic value of these methods regarding pathological (right ventricular infarction, pulmonary hypertension, arrhythmogenic right ventricular dysplasia, follow-up of heart transplantation) and even physiological (athlete's heart) alterations of the right ventricle. Orv. Hetil., 2016, 157(29), 1139-1146.

  20. Evaluation of the clinical process in a critical care information system using the Lean method: a case study

    Directory of Open Access Journals (Sweden)

    Yusof Maryati Mohd

    2012-12-01

    Full Text Available Abstract Background There are numerous applications for Health Information Systems (HIS that support specific tasks in the clinical workflow. The Lean method has been used increasingly to optimize clinical workflows, by removing waste and shortening the delivery cycle time. There are a limited number of studies on Lean applications related to HIS. Therefore, we applied the Lean method to evaluate the clinical processes related to HIS, in order to evaluate its efficiency in removing waste and optimizing the process flow. This paper presents the evaluation findings of these clinical processes, with regards to a critical care information system (CCIS, known as IntelliVue Clinical Information Portfolio (ICIP, and recommends solutions to the problems that were identified during the study. Methods We conducted a case study under actual clinical settings, to investigate how the Lean method can be used to improve the clinical process. We used observations, interviews, and document analysis, to achieve our stated goal. We also applied two tools from the Lean methodology, namely the Value Stream Mapping and the A3 problem-solving tools. We used eVSM software to plot the Value Stream Map and A3 reports. Results We identified a number of problems related to inefficiency and waste in the clinical process, and proposed an improved process model. Conclusions The case study findings show that the Value Stream Mapping and the A3 reports can be used as tools to identify waste and integrate the process steps more efficiently. We also proposed a standardized and improved clinical process model and suggested an integrated information system that combines database and software applications to reduce waste and data redundancy.

  1. [Psychoanalysis: a research method based on clinical practice: contributions to nursing].

    Science.gov (United States)

    da Silva, Teresa Cristina; Kirschbaum, Débora Isane Ratner

    2008-09-01

    Nursing, in its different fields of practice, is essentially characterized as a clinical practice. In this context, psychoanalysis can make important contributions. This article discusses some basic psychoanalytical concepts and assumptions, proposes psychoanalysis as a research method, and stresses its contributions for nursing. Essential Freudian concepts are identified, as well as the path to be followed by the researcher. As a research method, psychoanalysis can be used as a framework for the studu of human behavior based on unconscious mental processes. In several knowledge areas.

  2. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans

    2014-01-01

    a substantially larger number of clinical scapular assessment methods than previously reported. Using the COSMIN checklist the methodological quality of the included measurement properties in the reliability and validity domains were in general ‘‘fair’’ to ‘‘poor’’. None were examined for all three domains: (1...... utility for clinical practice.......The aims were to compile a schematic overview of clinical scapular assessment methods and critically appraise the methodological quality of the involved studies. A systematic, computerassisted literature search using Medline, CINAHL, SportDiscus and EMBASE was performed from inception to October...

  3. Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, Birgit; Lund, Hans

    %), with only one study rated as ‘good’. The reliability domain was most often investigated. Fewof the assessment methods in the included studies that had ‘fair’ or ‘good’ measurement properties demonstrated acceptable results for both reliability and validity.ConclusionWe found a substantially larger number......ABSTRACT OARSI Measurement properties of existing clinical assessment methods evaluating scapular positioning and function. A systematic review Larsen CM1, Juul-Kristensen B1,2 Lund H1,2, Søgaard K11University of Southern Denmark, Institute of Sports Science and Clinical Biomechanics2Institute...... assessment methods have measured the degree of scapular dyskinesis, subjectively by visual evaluation and objectively by measurements of static and dynamic scapular positioning, by either a 3-dimensional electromagnetic device or 2-dimensional clinically applicable methods. Since advanced equipment (i.e. 3D...

  4. Pulsed and Tissue Doppler Echocardiographic Changes in Patients with Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Taysir S. Garadah

    2010-01-01

    Full Text Available Background Doppler echocardiographic studies of left ventricle (LV systolic and diastolic function in patients with β-Thalassemia Major (β-TM had shown different patterns of systolic and diastolic dysfunction. Aim This cross-sectional study was designed to study the LV systolic and diastolic function in patients with β-TM using Pulsed Doppler (PD and Tissue Doppler (TD echocardiography. Methods All patients were evaluated clinically and by echocardiography, The study included patients with β-TM (n = 38, age 15.7 ± 8.9 years compared with an age-matched control group (n = 38, age 15.9 ± 8.9 years. The pulse Doppler indices were normalized for age and heart rate. Results Compared with control patients, M-Mode showed that patients with β-TM have thicker LV septal wall index (0.659 ± 0.23 vs. 0.446 ± 0.219 cm, P ≤ 0.001, posterior wall index (0.659 ± 0.235 vs. 0.437 ± 0.214 cm, P ≤ 0.01, and larger LVEDD index is (3.99 ± 0.48 vs. 2.170 ± 0.57 mm. P = 0.035. Pulsed Doppler showed high LV trans-mitral E wave velocity (70.818 ± 10.139 vs. 57.532 ± 10.139, p = 0.027 and E/A ratio (1.54 vs. 1.23, P ≤ 0.01. The duration of Deceleration time (DT and isovolumic relaxation time (IVRT were significantly shorter in patients with β-TM (150.234 ± 20.0.23 vs. 167.123 ± 19.143 msec, P ≤ 0.01 and (60.647 ± 6.77 vs. 75.474 ± 5.83 msec, P ≤ 0.001, respectively. The ratio of transmitral E wave velocity to the tissue Doppler E wave at the basal septal mitral annulus E/Em – was significantly higher in β-TM group (14.024 ± 2.29 vs. 12.132 ± 1.82, P ≤ 0.01. The Tissue Doppler systolic velocity (Sm and the early diastolic velocity (Em were significantly lower in β-TM group compared to control (4.31 ± 1.2 cm/s vs. 6.95 ± 2.1, P ≤ 0.01 and 4.31 ± 2.7 cm/s vs. 5.82 ± 2.5, P ≤ 0.01 respectively. The tricuspid valve velocity was significantly higher than controls (2.993 ± 0.569 vs. 1.93 ± 0.471 m/sec, respectively, P ≤ 0

  5. Legal clinic gender sensitive method for law students

    Directory of Open Access Journals (Sweden)

    Petrušić Nevena

    2008-01-01

    Full Text Available In this paper, the authors discuss models of integrating gender issues, gender perspective and some gender aspects into the university education. In that context, the authors particularly focus on the concept of clinical legal education in legal clinics offering a specific practical model of teaching gender studies. Legal clinics provide for an innovative approach to gender education of prospective legal professional. The teaching method used in these legal clinics is aimed at raising students' awareness of gender issues and common gender-related biases. In the recent period, the Legal Clinic at the Law Faculty in Niš has achieved excellent results in the Clinical legal education program on the women's rights protection, which clearly proves that legal clinics have good prospects in general legal education.

  6. Quantifying Diastolic Function: From E-Waves as Triangles to Physiologic Contours via the 'Geometric Method'.

    Science.gov (United States)

    Golman, Mikhail; Padovano, William; Shmuylovich, Leonid; Kovács, Sándor J

    2018-03-01

    Conventional echocardiographic diastolic function (DF) assessment approximates transmitral flow velocity contours (Doppler E-waves) as triangles, with peak (E peak ), acceleration time (AT), and deceleration time (DT) as indexes. These metrics have limited value because they are unable to characterize the underlying physiology. The parametrized diastolic filling (PDF) formalism provides a physiologic, kinematic mechanism based characterization of DF by extracting chamber stiffness (k), relaxation (c), and load (x o ) from E-wave contours. We derive the mathematical relationship between the PDF parameters and E peak , AT, DT and thereby introduce the geometric method (GM) that computes the PDF parameters using E peak , AT, and DT as input. Numerical experiments validated GM by analysis of 208 E-waves from 31 datasets spanning the full range of clinical diastolic function. GM yielded indistinguishable average parameter values per subject vs. the gold-standard PDF method (k: R 2  = 0.94, c: R 2  = 0.95, x o : R 2  = 0.95, p PDF method to quantify DF in terms of physiologic chamber properties.

  7. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  8. ECHOCARDIOGRAPHIC AND LABORATORY MARKERS OF CHRONIC HEART FAILURE: WHETHER IT IS POSSIBLE TO USE THEM IN RHEUMATIC MITRAL DISEASES?

    Directory of Open Access Journals (Sweden)

    T. A. Kazakovtseva

    2009-01-01

    Full Text Available Aim. To find echocardiographic indicators of heart remodelling that improve estimation of heart failure (HF severity. To evaluate sensitivity of laboratory markers of HF, brain (BNP and atrial (ANP natriuretic peptides, in patients with mitral heart diseases of rheumatic aetiology.Material and methods. 100 patients with rheumatic mitral disease and chronic HF (CHF of I-IV class (NYHA were examined. Echocardiography was performed in all patients with evaluation of the standard indices to define disease severity. Indices of sphericity, myocardial stress of the left ventricle, etc were also evaluated. BNP and ANB levels were assessed by enzyme immunoassay method.Results. CHF severity had the strongest correlations with atrial sizes, left atrial systolic function and level of pulmonary hypertension. Moderate increase of BNP level in severe CHF (III-IV class and its rare increase in mild CHF (I-II class were detected. Significant changes of ANP level were not found. Moderate correlation of BNP level with myocardium mass index, level of pulmonary hypertension and mitral regurgitation was detected.Conclusion. Intensity of heart remodelling in rheumatic mitral diseases is mainly determined by the left atrial area, left atrial systolic function, mitral orifice size, levels of mitral regurgitation and pulmonary hypertension, size and ejection fraction of right ventricle. Normal BNP level does not confirm an absence of CHF or negative prognosis in patients with rheumatic heart disease.

  9. Office blood pressure, ambulatory blood pressure monitoring, and echocardiographic abnormalities in women with polycystic ovary syndrome: role of obesity and androgen excess.

    Science.gov (United States)

    Luque-Ramírez, Manuel; Martí, David; Fernández-Durán, Elena; Alpañés, Macarena; Álvarez-Blasco, Francisco; Escobar-Morreale, Héctor F

    2014-03-01

    Whether or not blood pressure (BP) and heart function of women with polycystic ovary syndrome (PCOS) are altered remains unclear, albeit subtle abnormalities in the regulation of BP observed in these women might suggest a mild masculinization of their cardiovascular system. To study the influence of obesity and androgen excess on BP and echocardiographic profiles of women with the syndrome, we conducted a cross-sectional case-control study comparing office and ambulatory BP monitoring, as well as echocardiographic assessments, in 63 premenopausal women with the classic phenotype, 33 nonhyperandrogenic women with regular menses, and 25 young men. Forty-nine subjects were lean and 72 had weight excess (body mass index ≥25 kg/m(2)). Participants had no previous history of hypertension and were nonsmokers. Men showed the highest BP readings, and the lowest readings were observed in control women, whereas women with PCOS had intermediate values. Undiagnosed hypertension was more common in subjects with weight excess irrespective of sex and hyperandrogenism. Women with PCOS and weight excess showed frequencies of previously undiagnosed hypertension that were similar to those of men with weight excess and higher than those observed in nonhyperandrogenic women. Lastly, male sex, weight excess and hypertension, the latter in men as well as in women with PCOS, increased left ventricular wall thickness. In summary, our results show that patients with classic PCOS and weight excess frequently have undiagnosed BP abnormalities, leading to target organ damage.

  10. The glenoid track: a review of the clinical relevance, method of calculation and current evidence behind this method

    Energy Technology Data Exchange (ETDEWEB)

    Younan, Yara; Wong, Philip K.; Umpierrez, Monica; Gonzalez, Felix; Singer, Adam Daniel [Emory University Hospital, Department of Radiology and Imaging Sciences, Section of Musculoskeletal Imaging, Atlanta, GA (United States); Karas, Spero [Emory University Hospital, Department of Orthopedic Surgery, Atlanta, GA (United States); Jose, Jean [University of Miami, Department of Radiology, Miami, FL (United States)

    2017-12-15

    In the setting of bipolar bone injury, orthopedic surgeons are currently making use of the glenoid track method to guide surgical management. Using preoperative CT or MR imaging, this method allows the identification of patients who are more likely to fail a primary capsuloligamentous Bankart repair. As the glenoid track method becomes increasingly used in preoperative planning, it is important for the radiologist to become familiar with its concept and method of calculation. This review article aims to concisely summarize the current literature and the clinical implications of the glenoid track method. (orig.)

  11. Medical school clinical placements - the optimal method for assessing the clinical educational environment from a graduate entry perspective.

    Science.gov (United States)

    Hyde, Sarah; Hannigan, Ailish; Dornan, Tim; McGrath, Deirdre

    2018-01-05

    Educational environment is a strong determinant of student satisfaction and achievement. The learning environments of medical students on clinical placements are busy workplaces, composed of many variables. There is no universally accepted method of evaluating the clinical learning environment, nor is there consensus on what concepts or aspects should be measured. The aims of this study were to compare the Dundee ready educational environment measure (DREEM - the current de facto standard) and the more recently developed Manchester clinical placement index (MCPI) for the assessment of the clinical learning environment in a graduate entry medical student cohort by correlating the scores of each and analysing free text comments. This study also explored student perceptionof how the clinical educational environment is assessed. An online, anonymous survey comprising of both the DREEM and MCPI instruments was delivered to students on clinical placement in a graduate entry medical school. Additional questions explored students' perceptions of instruments for giving feedback. Numeric variables (DREEM score, MCPI score, ratings) were tested for normality and summarised. Pearson's correlation coefficient was used to measure the strength of the association between total DREEM score and total MCPI scores. Thematic analysis was used to analyse the free text comments. The overall response rate to the questionnaire was 67% (n = 180), with a completed response rate for the MCPI of 60% (n = 161) and for the DREEM of 58% (n = 154). There was a strong, positive correlation between total DREEM and MCPI scores (r = 0.71, p < 0.001). On a scale of 0 to 7, the mean rating for how worthwhile students found completing the DREEM was 3.27 (SD 1.41) and for the MCPI was 3.49 (SD 1.57). 'Finding balance' and 'learning at work' were among the themes to emerge from analysis of free text comments. The present study confirms that DREEM and MCPI total scores are strongly correlated

  12. Tremor Detection Using Parametric and Non-Parametric Spectral Estimation Methods: A Comparison with Clinical Assessment

    Science.gov (United States)

    Martinez Manzanera, Octavio; Elting, Jan Willem; van der Hoeven, Johannes H.; Maurits, Natasha M.

    2016-01-01

    In the clinic, tremor is diagnosed during a time-limited process in which patients are observed and the characteristics of tremor are visually assessed. For some tremor disorders, a more detailed analysis of these characteristics is needed. Accelerometry and electromyography can be used to obtain a better insight into tremor. Typically, routine clinical assessment of accelerometry and electromyography data involves visual inspection by clinicians and occasionally computational analysis to obtain objective characteristics of tremor. However, for some tremor disorders these characteristics may be different during daily activity. This variability in presentation between the clinic and daily life makes a differential diagnosis more difficult. A long-term recording of tremor by accelerometry and/or electromyography in the home environment could help to give a better insight into the tremor disorder. However, an evaluation of such recordings using routine clinical standards would take too much time. We evaluated a range of techniques that automatically detect tremor segments in accelerometer data, as accelerometer data is more easily obtained in the home environment than electromyography data. Time can be saved if clinicians only have to evaluate the tremor characteristics of segments that have been automatically detected in longer daily activity recordings. We tested four non-parametric methods and five parametric methods on clinical accelerometer data from 14 patients with different tremor disorders. The consensus between two clinicians regarding the presence or absence of tremor on 3943 segments of accelerometer data was employed as reference. The nine methods were tested against this reference to identify their optimal parameters. Non-parametric methods generally performed better than parametric methods on our dataset when optimal parameters were used. However, one parametric method, employing the high frequency content of the tremor bandwidth under consideration

  13. Tracing the evolution of chiropractic students’ confidence in clinical and patient communication skills during a clinical internship: a multi-methods study

    Science.gov (United States)

    2012-01-01

    Background Anecdotal evidence points to variations in individual students’ evolving confidence in clinical and patient communication skills during a clinical internship. A better understanding of the specific aspects of internships that contribute to increasing or decreasing confidence is needed to best support students during the clinical component of their study. Methods A multi-method approach, combining two large-scale surveys with 269 students and three in-depth individual interviews with a sub-sample of 29 students, was used to investigate the evolution of change in student confidence during a 10-month long internship. Change in levels of confidence in patient communication and clinical skills was measured and relationship to demographic factors were explored. The interviews elicited students’ accounts and reflections on what affected the evolution of their confidence during the internship. Results At the start of their internship, students were more confident in their patient communication skills than their clinical skills but prior experience was significantly related to confidence in both. Initial confidence in patient communication skills was also related to age and prior qualification but not gender whilst confidence in clinical skills was related to gender but not age or prior qualification. These influences were maintained over time. Overall, students’ levels of confidence in patient communication and clinical skills confidence increased significantly over the duration of the internship with evidence that change over time in these two aspects were inter-related. To explore how specific aspects of the internship contributed to changing levels of confidence, two extreme sub-groups of interviewees were identified, those with the least increase and those with the highest increase in professional confidence over time. A number of key factors affecting the development of confidence were identified, including among others, interactions with clinicians

  14. Achados ecocardiográficos em crianças com sopro "inocente" Echocardiographic findings in children with innocent murmur

    Directory of Open Access Journals (Sweden)

    Cora Firpo

    2006-08-01

    Full Text Available OBJETIVOS: Avaliar a freqüência de alterações ecocardiográficas em pacientes com diagnóstico de sopro "inocente". Métodos. Estudo transversal de uma amostra de 166 pacientes com diagnóstico de sopro "inocente" avaliados no ambulatório de Cardiologia Pediátrica do Instituto de Cardiologia/Fundação Universitária de Cardiologia, um serviço terciário de referência, durante o período de 3/12/2001 a 2/12/2002. Todos os pacientes realizaram anamnese, exame físico, eletrocardiograma e ecocardiograma. Foram estimadas as probabilidades pós-teste de exame clínico considerando o ecocardiograma como padrão ouro. Resultados. Dos 166 pacientes estudados, 11 apresentaram alguma alteração ao ecocardiograma: estenose pulmonar leve (4, forame oval patente (2, aorta bicúspide (2, comunicação interatrial (1, insuficiência aórtica mínima (1, comunicação interventricular mínima (1. A probabilidade pós-teste negativo, ou seja, a probabilidade de lesão cardíaca com diagnóstico de sopro "inocente" foi de 6,6%. Conclusão. Em ambulatório especializado, é alta a proporção de alterações ecocardiográficas em pacientes com diagnóstico de sopro "inocente". Estes achados podem não estar relacionados à presença de sopro, como o forame oval patente e a aorta bicúspide. No entanto, levantam a questão da indicação de ecocardiograma considerando, por um lado, o baixo risco das lesões detectadas e, por outro, o caráter resolutivo de um ambulatório de referência.OBJECTIVES: To access the frequency of abnormal echocardiographic findings in patients with diagnosis of innocent murmur. METHODS: A transversal study of 166 consecutive patients was carried out with diagnosis of innocent murmur evaluated in the pediatric cardiology outpatient clinic of "Instituto de Cardiologia/Fundação Universitária de Cardiologia", a tertiary reference center, between December 3, 2001 and December 2, 2002. History, clinical examination and

  15. Rheumatic Heart Disease in Kerala: A Vanishing Entity? An Echo Doppler Study in 5–15-Years-Old School Children

    Directory of Open Access Journals (Sweden)

    Bigesh Nair

    2015-01-01

    Full Text Available Background. Early detection of subclinical rheumatic heart disease by use of echocardiography warrants timely implementation of secondary antibiotic prophylaxis and thereby prevents or retards its related complications. Objectives. The objective of this epidemiological study was to determine prevalence of RHD by echocardiography using World Heart Federation criteria in randomly selected school children of Trivandrum. Methods. This was a population-based cross-sectional screening study carried out in Trivandrum. A total of 2060 school children, 5–15 years, were randomly selected from five government and two private (aided schools. All enrolled children were screened for RHD according to standard clinical and WHF criteria of echocardiography. Results. Echocardiographic examinations confirmed RHD in 5 children out of 146 clinically suspected cases. Thus, clinical prevalence was found to be 2.4 per 1000. According to WHF criteria of echocardiography, 12 children (12/2060 were diagnosed with RHD corresponding to echocardiographic prevalence of 5.83 cases per 1000. As per criteria, 6 children were diagnosed with definite RHD and 6 with borderline RHD. Conclusions. The results of the current study demonstrate that echocardiography is more sensitive and feasible in detecting clinically silent RHD. Our study, the largest school survey of south India till date, points towards declining prevalence of RHD (5.83/1000 cases using WHF criteria in Kerala.

  16. A Quality Assurance Method that Utilizes 3D Dosimetry and Facilitates Clinical Interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, Mark, E-mail: mark.oldham@duke.edu [Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Thomas, Andrew; O' Daniel, Jennifer; Juang, Titania [Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Ibbott, Geoffrey [University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Adamovics, John [Rider University, Lawrenceville, New Jersey (United States); Kirkpatrick, John P. [Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2012-10-01

    Purpose: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehensive dosimetry verification and facilitates evaluation of the clinical significance of QA data acquired in a phantom. Also to apply the method to investigate the dosimetric efficacy of base-of-skull (BOS) intensity-modulated radiotherapy (IMRT) treatment. Methods and Materials: Two types of IMRT QA verification plans were created for 6 patients who received BOS IMRT. The first plan enabled conventional 2D planar IMRT QA using the Varian portal dosimetry system. The second plan enabled 3D verification using an anthropomorphic head phantom. In the latter, the 3D dose distribution was measured using the DLOS/Presage dosimetry system (DLOS = Duke Large-field-of-view Optical-CT System, Presage Heuris Pharma, Skillman, NJ), which yielded isotropic 2-mm data throughout the treated volume. In a novel step, measured 3D dose distributions were transformed back to the patient's CT to enable calculation of dose-volume histograms (DVH) and dose overlays. Measured and planned patient DVHs were compared to investigate clinical significance. Results: Close agreement between measured and calculated dose distributions was observed for all 6 cases. For gamma criteria of 3%, 2 mm, the mean passing rate for portal dosimetry was 96.8% (range, 92.0%-98.9%), compared to 94.9% (range, 90.1%-98.9%) for 3D. There was no clear correlation between 2D and 3D passing rates. Planned and measured dose distributions were evaluated on the patient's anatomy, using DVH and dose overlays. Minor deviations were detected, and the clinical significance of these are presented and discussed. Conclusions: Two advantages accrue to the methods presented here. First, treatment accuracy is evaluated throughout the whole treated volume, yielding comprehensive verification. Second, the clinical significance of any deviations can be assessed through the generation of DVH curves and dose overlays on

  17. High prevalence of rheumatic heart disease detected by echocardiography in school children.

    Science.gov (United States)

    Bhaya, Maneesha; Panwar, Sadik; Beniwal, Rajesh; Panwar, Raja Babu

    2010-04-01

    It is fairly easy to detect advanced valve lesions of established rheumatic heart disease by echocardiography in the clinically identified cases of rheumatic heart disease. However, to diagnose a subclinical case of rheumatic heart disease, no uniform set of echocardiographic criteria exist. Moderate thickening of valve leaflets is considered an indicator of established rheumatic heart disease. World Health Organization criteria for diagnosing probable rheumatic heart disease are more sensitive and are based on the detection of significant regurgitation of mitral and/or aortic valves by color Doppler. We attempted diagnosing RHD in school children in Bikaner city by cardiac ultrasound. The stratified cluster sampling technique was employed to identify 31 random clusters in the coeducational schools of Bikaner city. We selected 1059 school children aged 6-15 years from these schools. An experienced operator did careful cardiac auscultation and echocardiographic study. A second expert confirmed the echocardiographic findings. The prevalence of lesions suggestive of rheumatic heart disease by echocardiography was 51 per 1,000 (denominator = 1059; 95% CI: 38-64 per 1,000). We were able to clinically diagnose RHD in one child. None of these children or their parents having echocardiographic evidence of RHD could provide a positive history of acute rheumatic fever. By echocardiographic screening, we found a high prevalence of rheumatic heart disease in the surveyed population. Clinical auscultation had much lower diagnostic efficacy.

  18. The early evolution of Jean Piaget's clinical method.

    Science.gov (United States)

    Mayer, Susan Jean

    2005-11-01

    This article analyzes the early evolution of Jean Piaget's renowned "clinical method" in order to investigate the method's strikingly original and generative character. Throughout his 1st decade in the field, Piaget frequently discussed and justified the many different approaches to data collection he used. Analysis of his methodological progression during this period reveals that Piaget's determination to access the genuine convictions of children eventually led him to combine 3 distinct traditions in which he had been trained-naturalistic observation, psychometrics, and the psychiatric clinical examination. It was in this amalgam, first evident in his 4th text, that Piaget discovered the clinical dynamic that would drive the classic experiments for which he is most well known.

  19. Acute beneficial hemodynamic effects of a novel 3D-echocardiographic optimization protocol in cardiac resynchronization therapy.

    Directory of Open Access Journals (Sweden)

    Carolin Sonne

    Full Text Available BACKGROUND: Post-implantation therapies to optimize cardiac resynchronization therapy (CRT focus on adjustments of the atrio-ventricular (AV delay and ventricular-to-ventricular (VV interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE and three-dimensional echocardiography (3DE for individualized optimization of device based AV delays and VV intervals compared to empiric programming. METHODS: 25 recipients of CRT (male: 56%, mean age: 67 years were included in this study. Ejection fraction (EF, the primary outcome parameter, and left ventricular (LV dimensions were evaluated by 3DE before CRT (baseline, after AV delay optimization while pacing the ventricles simultaneously (empiric VV interval programming and after individualized VV interval optimization. For AV delay optimization aortic velocity time integral (AoVTI was examined in eight different AV delays, and the AV delay with the highest AoVTI was programmed. For individualized VV interval optimization 3DE full-volume datasets of the left ventricle were obtained and analyzed to derive a systolic dyssynchrony index (SDI, calculated from the dispersion of time to minimal regional volume for all 16 LV segments. Consecutively, SDI was evaluated in six different VV intervals (including LV or right ventricular preactivation, and the VV interval with the lowest SDI was programmed (individualized optimization. RESULTS: EF increased from baseline 23±7% to 30±8 (p<0.001 after AV delay optimization and to 32±8% (p<0.05 after individualized optimization with an associated decrease of end-systolic volume from a baseline of 138±60 ml to 115±42 ml (p<0.001. Moreover, individualized optimization significantly reduced SDI from a baseline of 14.3±5.5% to 6.1±2.6% (p<0.001. CONCLUSIONS: Compared with empiric programming of biventricular pacemakers

  20. Splenectomized versus non-splenectomized patients with thalassemia major: Echocardiographic comparison

    International Nuclear Information System (INIS)

    Morsy, Mohamed-Mofeed F.; Ahmed, Ali A.; Al-Najjar, Abdulhameed A.; Almuzainy, Ibrahim S.; Alhawsawi, Zakria M.; Alserafi, Mona H.

    2008-01-01

    Objective was to study the effect of splenectomy in patients with thalassemia major on the cardiovascular system through echocardiographic study. A prospective, cross-sectional study was carried out from December 2006 to December 2007. Patients from the Thalassemia Center in the Maternity and Children's Hospital, Madina, Kingdom of Saudi Arabia, were screened by means of history, physical examination, laboratory studies and echocardiography. Fifty-seven patients were studied: 36 were non-splenectomized, while 21 were surgically splenectomized. The 2 study groups were well matched for age, gender, height and weight. The total amount of blood given previous year (6577+-206.9 ml versus 5390.5+-220.2 ml, p=0.0005) and the annual transfusion index (200.9+-11.3 ml versus 134.1+-7.3, p=0.0001) were significantly lower in the splenectomized group. There was no significant difference between 2 groups regarding laboratory studies. Left ventricular systolic function shows no difference regarding fraction shortening between the 2 groups. The mitral valve E/A ratio was significantly higher in the splenectomized group (1.6+-0.2 versus1.4+-0.2, p=0.02). The pulmonary artery pressure was higher in the splenectomized group (34.2+-9.1 versus 20.8+-9.2 mm Hg, p=0.0001). There was a significantly higher number of patients with pulmonary hypertension in the splenectomized group (14[66.7%] versus 6[1.7%], p=0.0004). Splenectomized patients with thalassemia major are at high risk of having impaired diastolic left ventricular function and pulmonary hypertension. (author)

  1. Serial Echocardiographic Characteristics, Novel Biomarkers and Cachexia Development in Patients with Stable Chronic Heart Failure.

    Science.gov (United States)

    Gaggin, Hanna K; Belcher, Arianna M; Gandhi, Parul U; Ibrahim, Nasrien E; Januzzi, James L

    2016-12-01

    Little is known regarding objective predictors of cachexia affecting patients with heart failure (HF). We studied 108 stable chronic systolic HF patients with serial echocardiography and biomarker measurements over 10 months. Cachexia was defined as weight loss ≥5 % from baseline or final BMI cachexia. While there were no significant differences in baseline or serial echocardiographic measures in those developing cachexia, we found significant differences in baseline amino-terminal pro-B type natriuretic peptide (NT-proBNP), highly sensitive troponin I, sST2, and endothelin-1. Baseline log NT-proBNP (hazard ratio (HR) = 2.57, p = 0.004) and edema (HR = 3.36, p = 0.04) were predictive of cachexia in an adjusted analysis. When serial measurement of biomarkers was considered, only percent time with NT-proBNP ≥1000 pg/mL was predictive of cachexia. Thus, a close association exists between baseline and serial measurement of NT-proBNP and HF cachexia.

  2. Processing methods for photoacoustic Doppler flowmetry with a clinical ultrasound scanner

    Science.gov (United States)

    Bücking, Thore M.; van den Berg, Pim J.; Balabani, Stavroula; Steenbergen, Wiendelt; Beard, Paul C.; Brunker, Joanna

    2018-02-01

    Photoacoustic flowmetry (PAF) based on time-domain cross correlation of photoacoustic signals is a promising technique for deep tissue measurement of blood flow velocity. Signal processing has previously been developed for single element transducers. Here, the processing methods for acoustic resolution PAF using a clinical ultrasound transducer array are developed and validated using a 64-element transducer array with a -6 dB detection band of 11 to 17 MHz. Measurements were performed on a flow phantom consisting of a tube (580 μm inner diameter) perfused with human blood flowing at physiological speeds ranging from 3 to 25 mm / s. The processing pipeline comprised: image reconstruction, filtering, displacement detection, and masking. High-pass filtering and background subtraction were found to be key preprocessing steps to enable accurate flow velocity estimates, which were calculated using a cross-correlation based method. In addition, the regions of interest in the calculated velocity maps were defined using a masking approach based on the amplitude of the cross-correlation functions. These developments enabled blood flow measurements using a transducer array, bringing PAF one step closer to clinical applicability.

  3. Clinical simulation as an evaluation method in health informatics

    DEFF Research Database (Denmark)

    Jensen, Sanne

    2016-01-01

    Safe work processes and information systems are vital in health care. Methods for design of health IT focusing on patient safety are one of many initiatives trying to prevent adverse events. Possible patient safety hazards need to be investigated before health IT is integrated with local clinical...... work practice including other technology and organizational structure. Clinical simulation is ideal for proactive evaluation of new technology for clinical work practice. Clinical simulations involve real end-users as they simulate the use of technology in realistic environments performing realistic...... tasks. Clinical simulation study assesses effects on clinical workflow and enables identification and evaluation of patient safety hazards before implementation at a hospital. Clinical simulation also offers an opportunity to create a space in which healthcare professionals working in different...

  4. Using digital photography in a clinical setting: a valid, accurate, and applicable method to assess food intake.

    Science.gov (United States)

    Winzer, Eva; Luger, Maria; Schindler, Karin

    2018-06-01

    Regular monitoring of food intake is hardly integrated in clinical routine. Therefore, the aim was to examine the validity, accuracy, and applicability of an appropriate and also quick and easy-to-use tool for recording food intake in a clinical setting. Two digital photography methods, the postMeal method with a picture after the meal, the pre-postMeal method with a picture before and after the meal, and the visual estimation method (plate diagram; PD) were compared against the reference method (weighed food records; WFR). A total of 420 dishes from lunch (7 weeks) were estimated with both photography methods and the visual method. Validity, applicability, accuracy, and precision of the estimation methods, and additionally food waste, macronutrient composition, and energy content were examined. Tests of validity revealed stronger correlations for photography methods (postMeal: r = 0.971, p < 0.001; pre-postMeal: r = 0.995, p < 0.001) compared to the visual estimation method (r = 0.810; p < 0.001). The pre-postMeal method showed smaller variability (bias < 1 g) and also smaller overestimation and underestimation. This method accurately and precisely estimated portion sizes in all food items. Furthermore, the total food waste was 22% for lunch over the study period. The highest food waste was observed in salads and the lowest in desserts. The pre-postMeal digital photography method is valid, accurate, and applicable in monitoring food intake in clinical setting, which enables a quantitative and qualitative dietary assessment. Thus, nutritional care might be initiated earlier. This method might be also advantageous for quantitative and qualitative evaluation of food waste, with a resultantly reduction in costs.

  5. Clinical Classification and Prognosis of Isolated Right-Sided Infective Endocarditis

    Science.gov (United States)

    Ortiz, Carlos; López, Javier; García, Héctor; Sevilla, Teresa; Revilla, Ana; Vilacosta, Isidre; Sarriá, Cristina; Olmos, Carmen; Ferrera, Carlos; García, Pablo Elpidio; Sáez, Carmen; Gómez, Itziar; San Román, José Alberto

    2014-01-01

    Abstract From an epidemiologic point of view, right-sided infective endocarditis (RSIE) affects different types of patients: intravenous drug users (IDUs), cardiac device carriers (pacemakers and implantable automatic defibrillators), and the “3 noes” endocarditis group: no left-sided, no IDUs, no cardiac devices. Our objective is to describe and compare the clinical profile and outcome of these groups of patients. Every episode of infective endocarditis (IE) consecutively diagnosed in 3 tertiary centers from 1996 to 2012 was included in an ongoing multipurpose database. We assessed 85 epidemiologic, clinical, echocardiographic, and outcome variables in patients with isolated RSIE. A bivariated comparative analysis between the 3 groups was conducted. Among 866 IE episodes, 121 were classified as isolated RSIE (14%): 36 IDUs (30%), 65 cardiac device carriers (54%), and 20 “3 noes” group (16%). IDUs were mainly young men (36 ± 7 years) without previous heart disease, few comorbidities, and frequent previous endocarditis episodes (28%). Human immunodeficiency virus infection was frequent (69%). Cardiac device carriers were older (66 ± 15 years) and had less comorbidities (34%). Removal of the infected device was performed in 91% of the patients without any death. The “3 noes” endocarditis group was composed mainly by middle-age men (56 ± 18 years), health care related infections (50%), and had many comorbidities (75%). Whereas Staphylococcus aureus were the most frequent cause in IDUs (72% vs 34% in device carriers and 34% in the “3 noes” group, P = 0.001), coagulase negative Staphylococci predominated in the device carriers (58% vs 11% in drug users and 35% in the “3 noes”, P < 0.001). Significant differences in mortality were found (17% in drug users, 3% in device carriers, and 30% in the “3 noes” group; P < 0.001). These results suggest that RSIE should be separated into 3 groups (IDUs, cardiac device carriers, and

  6. LC-MS (/MS) in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Hochstrasser, Denis; Fathi, Marc

    2012-01-01

    Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.). For these reasons, an increasing number of applications are being published. This paper is a brief overview of LC-MS(/MS) screening methods developed for clinical toxicology in recent years. Various sample treatments, chromatographic separations and detection by mass spectrometry can be combined to obtain screening methods adapted to the constraints and needs of clinical toxicology laboratories. Currently the techniques are in the hands of specialists, mainly in academic institutions. However, the evolution in technology should allow application of these techniques as a tool in toxicology laboratories, thus allowing a more widespread exploitation of their potential.

  7. Flipped clinical training: a structured training method for undergraduates in complete denture prosthesis.

    Science.gov (United States)

    K, Anbarasi; K, Kasim Mohamed; Vijayaraghavan, Phagalvarthy; Kandaswamy, Deivanayagam

    2016-12-01

    To design and implement flipped clinical training for undergraduate dental students in removable complete denture treatment and predict its effectiveness by comparing the assessment results of students trained by flipped and traditional methods. Flipped training was designed by shifting the learning from clinics to learning center (phase I) and by preserving the practice in clinics (phase II). In phase I, student-faculty interactive session was arranged to recap prior knowledge. This is followed by a display of audio synchronized video demonstration of the procedure in a repeatable way and subsequent display of possible errors that may occur in treatment with guidelines to overcome such errors. In phase II, live demonstration of the procedure was given. Students were asked to treat three patients under instructor's supervision. The summative assessment was conducted by applying the same checklist criterion and rubric scoring used for the traditional method. Assessment results of three batches of students trained by flipped method (study group) and three traditionally trained previous batches (control group) were taken for comparison by chi-square test. The sum of traditionally trained three batch students who prepared acceptable dentures (score: 2 and 3) and unacceptable dentures (score: 1) was compared with the same of flipped trained three batch students revealed that the number of students who demonstrated competency by preparing acceptable dentures was higher for flipped training (χ 2 =30.996 with p<0.001). The results reveal the supremacy of flipped training in enhancing students competency and hence recommended for training various clinical procedures.

  8. Trypanosoma cruzi in dogs: electrocardiographic and echocardiographic evaluation, in Malinalco, State of Mexico

    Directory of Open Access Journals (Sweden)

    González-Vieyra SD

    2011-12-01

    Full Text Available Sandra Díaz González-Vieyra1, Ninfa Ramírez-Durán2, Ángel H Sandoval-Trujillo3, Juan C Vázquez-Chagoyán1, Humberto G Monroy-Salazar1, Alberto Barbabosa-Pliego11Research Center of Advanced Studies in Animal Health, Veterinary Husbandry School, 2Medical and Ambiental Microbiology, Research Center of Advanced Studies in Health Science, School of Medicine, Autonomous University of the State of Mexico, Toluca, Mexico; 3Department of Biological Systems, Metropolitan Autonomous University, Xochimilco, Mexico City, MexicoAbstract: Chagas disease caused by Trypanosoma cruzi is an important public health problem in Latin America. Dogs are considered a risk factor for human Chagas disease, a sentinel for T. cruzi infection in endemic regions and an animal model to study pathological aspects of the disease. The potential use of dogs as indicators of human cardiac pathogenicity of local T. cruzi strains has been studied insufficiently. We studied electrocardiographic (EKG and echocardiographic (ECG alteration frequencies observed in an open population of dogs in Malinalco, Mexico, and determined if such frequencies were statistically associated with T. cruzi infection in dogs. Animals (n = 139 were clinically examined and owners were asked to answer a questionnaire about dogs’ living conditions. Two commercial serological tests (IHA, ELISA were conducted to detect anti-T. cruzi serum antibodies. Significant differences between seropositive and seronegative animals in cardiomyopathic frequencies were detected through EKG and ECG (P < 0.05. Thirty dogs (21.58% were serologically positive to anti-T. cruzi antibodies (to ELISA and IHA assays, of which nine (30% had EKG and/or ECG alterations. From the remaining 104 (78.42% seronegative animals, five (4.5% had EKG and/or ECG abnormalities. Our data support the hypothesis that most EKG and ECG alterations found in dogs from Malinalco could be associated with T. cruzi infection. Considering the dog as a

  9. Automated patient and medication payment method for clinical trials

    Directory of Open Access Journals (Sweden)

    Yawn BP

    2013-01-01

    Full Text Available Barbara P Yawn,1 Suzanne Madison,1 Susan Bertram,1 Wilson D Pace,2 Anne Fuhlbrigge,3 Elliot Israel,3 Dawn Littlefield,1 Margary Kurland,1 Michael E Wechsler41Olmsted Medical Center, Department of Research, Rochester, MN, 2UCDHSC, Department of Family Medicine, University of Colorado Health Science Centre, Aurora, CO, 3Brigham and Women's Hospital, Pulmonary and Critical Care Division, Boston, MA, 4National Jewish Medical Center, Division of Pulmonology, Denver, CO, USABackground: Published reports and studies related to patient compensation for clinical trials focus primarily on the ethical issues related to appropriate amounts to reimburse for patient's time and risk burden. Little has been published regarding the method of payment for patient participation. As clinical trials move into widely dispersed community practices and more complex designs, the method of payment also becomes more complex. Here we review the decision process and payment method selected for a primary care-based randomized clinical trial of asthma management in Black Americans.Methods: The method selected is a credit card system designed specifically for clinical trials that allows both fixed and variable real-time payments. We operationalized the study design by providing each patient with two cards, one for reimbursement for study visits and one for payment of medication costs directly to the pharmacies.Results: Of the 1015 patients enrolled, only two refused use of the ClinCard, requesting cash payments for visits and only rarely a weekend or fill-in pharmacist refused to use the card system for payment directly to the pharmacy. Overall, the system has been well accepted by patients and local study teams. The ClinCard administrative system facilitates the fiscal accounting and medication adherence record-keeping by the central teams. Monthly fees are modest, and all 12 study institutional review boards approved use of the system without concern for patient

  10. Clinical Applications of Natriuretic Peptides in Assessment of Valvular Heart Disease

    Directory of Open Access Journals (Sweden)

    Abhishek Sharma

    2015-01-01

    Full Text Available Biomarkers such as natriuretic peptides (NPs have evolving clinical utility beyond the scope of heart failure. The role of NPs in the management of valvular heart disease is a growing area of investigation. NPs have much potential in the assessment of asymptomatic patients with hemodynamically significant valvular lesions who have traditionally been excluded from consideration of surgical intervention. NPs also have a role in the risk stratification of these patients as well as in routine surveillance and monitoring. Together with echocardiographic data and functional status, NPs are being incorporated into the management of valvular heart disease. In this review we examine the evidence for the role of natriuretic peptides in assessment of VHD.

  11. Clinical Applications of Natriuretic Peptides in Assessment of Valvular Heart Disease

    Science.gov (United States)

    Ahmed, Vaseem; Garg, Aakash; Aggarwal, Chirag

    2015-01-01

    Biomarkers such as natriuretic peptides (NPs) have evolving clinical utility beyond the scope of heart failure. The role of NPs in the management of valvular heart disease is a growing area of investigation. NPs have much potential in the assessment of asymptomatic patients with hemodynamically significant valvular lesions who have traditionally been excluded from consideration of surgical intervention. NPs also have a role in the risk stratification of these patients as well as in routine surveillance and monitoring. Together with echocardiographic data and functional status, NPs are being incorporated into the management of valvular heart disease. In this review we examine the evidence for the role of natriuretic peptides in assessment of VHD. PMID:26265794

  12. Echocardiographic knowledge-based reconstruction for quantification of the systemic right ventricle in young adults with repaired D-transposition of great arteries.

    Science.gov (United States)

    Kutty, Shelby; Li, Ling; Polak, Amanda; Gribben, Paul; Danford, David A

    2012-03-15

    The systemic right ventricle (RV) in congenital heart disease is susceptible to progressive dilation and dysfunction. A 2-dimensional echocardiographic means for serial monitoring of the RV would be of great value in this clinical setting. We used 2-dimensional echocardiography with knowledge-based reconstruction (2DE-KBR) for evaluation of systemic RV. Patients with d-transposition of great arteries repaired with an atrial switch and without implanted pacemakers were prospectively recruited for same-day 2DE-KBR and cardiac magnetic resonance (CMR) imaging. RV images were acquired in various 2-dimensional imaging planes using a 3-dimensional space-localizing device attached to the imaging transducer and 3-dimensional reconstruction was performed. RV end-diastolic volume, end-systolic volume, and ejection fraction (EF) were calculated and compared to volumetric CMR analysis. Fifteen patients (7 women, 8 men, 24 ± 7 years old, weight 67 ± 12 kg) were studied. There was good agreement of 2DE-KBR and CMR measurements. Mean RV end-diastolic volume was 221 ± 39 ml with 2DE-KBR and 231 ± 35 ml with CMR (r = 0.80); mean end-systolic volume was 129 ± 35 ml with KBR and 132 ± 30 ml with CMR (r = 0.82), and EF was 42 ± 10% with KBR and 43 ± 7% with CMR (r = 0.86). For 2DE-KBR mean interobserver variabilities were 4.6%, 2.6%, and 4.3%; intraobserver variabilities were 3.2%, 3.1%, and 2.3%, respectively, for end-diastolic volume, end-systolic volume, and EF. In conclusion, this study demonstrates the clinical feasibility of quantifying systemic RV volumes and function using 2DE-KBR in adolescents and young adults with repaired d-transposition of great arteries and good agreement of measurements with CMR. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. A comparison of photographic, replication and direct clinical examination methods for detecting developmental defects of enamel

    Directory of Open Access Journals (Sweden)

    Pakshir Hamid-Reza

    2011-04-01

    Full Text Available Abstract Background Different methods have been used for detecting developmental defects of enamel (DDE. This study aimed to compare photographic and replication methods with the direct clinical examination method for detecting DDE in children's permanent incisors. Methods 110 8-10-year-old schoolchildren were randomly selected from an examined sample of 335 primary Shiraz school children. Modified DDE index was used in all three methods. Direct examinations were conducted by two calibrated examiners using flat oral mirrors and tongue blades. Photographs were taken using a digital SLR camera (Nikon D-80, macro lens, macro flashes, and matt flash filters. Impressions were taken using additional-curing silicon material and casts made in orthodontic stone. Impressions and models were both assessed using dental loupes (magnification=x3.5. Each photograph/impression/cast was assessed by two calibrated examiners. Reliability of methods was assessed using kappa agreement tests. Kappa agreement, McNemar's and two-sample proportion tests were used to compare results obtained by the photographic and replication methods with those obtained by the direct examination method. Results Of the 110 invited children, 90 were photographed and 73 had impressions taken. The photographic method had higher reliability levels than the other two methods, and compared to the direct clinical examination detected significantly more subjects with DDE (P = 0.002, 3.1 times more DDE (P Conclusion The photographic method was much more sensitive than direct clinical examination in detecting DDE and was the best of the three methods for epidemiological studies. The replication method provided less information about DDE compared to photography. Results of this study have implications for both epidemiological and detailed clinical studies on DDE.

  14. [Echocardiographic indices of the right heart in patients with coronary artery disease in different age groups].

    Science.gov (United States)

    Gajfulin, R A; Sumin, A N; Arhipov, O G

    2016-01-01

    The aim of study was to examine echocardiographic indices of right heart chambers in patients with coronary artery disease in different age groups. On 678 patients aged 38-85 years, who underwent echocardiography, are including with the use of spectral tissue Doppler. Obtained 2 age groups: 1st - patients up to 60 years (n=282) and group 2nd - patients 60 years and older (n=396). In the analysis the obtained results in patients with coronary heart disease in older age groups showed an increase in right ventricular wall thickness, systolic and average pressure in the pulmonary artery. These changes were accompanied by deterioration in left ventricular diastolic function, while the systolic function of the left and right ventricle were independent of age. Thus, the results can be recommended for assessment of right ventricular dysfunction in patients of older age groups.

  15. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    Science.gov (United States)

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  16. Echocardiographic Wall Motion Abnormality in Posterior Myocardial Infarction: The Diagnostic Value of Posterior Leads

    Directory of Open Access Journals (Sweden)

    A Darehzereshki

    2008-06-01

    Full Text Available Background: For the purpose of ascertaining myocardial infarction (MI and ischemia, the sensitivity of the initial 12-lead ECG is inadequate. It is risky to diagnose posterior MI using only precordial reciprocal changes, since the other leads may be more optimally positioned for the identification of electrocardiographic changes. In this study, we evaluated the relationship between electrocardiography changes and wall motion abnormalities in patients with posterior MI for earlier and better diagnosis of posterior MI.Methods: In this prospective cross-sectional study, we enrolled patients with posterior MI who had come to the Emergency Department of Shariati Hospital with their first episode of chest pain. A 12-lead surface electrocardiogram using posterior leads (V7-V9 was performed for all participants. Patients with ST elevation >0.05 mV or pathologic Q wave in the posterior leads, as well as those with specific changes indicating posterior MI in V1-V2, were evaluated by echocardiography in terms of wall motion abnormalities. All data were analyzed using SPSS and p<0.05 were considered statistically significant.Results: Of a total 79 patients enrolled, 48 (60.8% were men, and the mean age was 57.35±8.22 years. Smoking (54.4% and diabetes (48% were the most prevalent risk factors. In the echocardiographic evaluation, all patients had wall motion abnormalities in the left ventricle and 19 patients (24.1% had wall motion abnormalities in the right ventricle. The most frequent segment with motion abnormality among the all patients was the mid-posterior. The posterior leads showed better positive predictive value than the anterior leads for posterior wall motion abnormality.Conclusion: Electrocardiography of the posterior leads in patients with acute chest pain can help in earlier diagnosis and in time treatment of posterior MI.

  17. Two-dimensional and Doppler echocardiographic findings in healthy non-sedated red-eared slider terrapins (Trachemys scripta elegans).

    Science.gov (United States)

    Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D

    2011-12-01

    Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.

  18. Four-chamber view and 'swing technique' (FAST) echo: a novel and simple algorithm to visualize standard fetal echocardiographic planes.

    Science.gov (United States)

    Yeo, L; Romero, R; Jodicke, C; Oggè, G; Lee, W; Kusanovic, J P; Vaisbuch, E; Hassan, S

    2011-04-01

    To describe a novel and simple algorithm (four-chamber view and 'swing technique' (FAST) echo) for visualization of standard diagnostic planes of fetal echocardiography from dataset volumes obtained with spatiotemporal image correlation (STIC) and applying a new display technology (OmniView). We developed an algorithm to image standard fetal echocardiographic planes by drawing four dissecting lines through the longitudinal view of the ductal arch contained in a STIC volume dataset. Three of the lines are locked to provide simultaneous visualization of targeted planes, and the fourth line (unlocked) 'swings' through the ductal arch image (swing technique), providing an infinite number of cardiac planes in sequence. Each line generates the following plane(s): (a) Line 1: three-vessels and trachea view; (b) Line 2: five-chamber view and long-axis view of the aorta (obtained by rotation of the five-chamber view on the y-axis); (c) Line 3: four-chamber view; and (d) 'swing line': three-vessels and trachea view, five-chamber view and/or long-axis view of the aorta, four-chamber view and stomach. The algorithm was then tested in 50 normal hearts in fetuses at 15.3-40 weeks' gestation and visualization rates for cardiac diagnostic planes were calculated. To determine whether the algorithm could identify planes that departed from the normal images, we tested the algorithm in five cases with proven congenital heart defects. In normal cases, the FAST echo algorithm (three locked lines and rotation of the five-chamber view on the y-axis) was able to generate the intended planes (longitudinal view of the ductal arch, pulmonary artery, three-vessels and trachea view, five-chamber view, long-axis view of the aorta, four-chamber view) individually in 100% of cases (except for the three-vessels and trachea view, which was seen in 98% (49/50)) and simultaneously in 98% (49/50). The swing technique was able to generate the three-vessels and trachea view, five-chamber view and/or long

  19. Machine learning methods for clinical forms analysis in mental health.

    Science.gov (United States)

    Strauss, John; Peguero, Arturo Martinez; Hirst, Graeme

    2013-01-01

    In preparation for a clinical information system implementation, the Centre for Addiction and Mental Health (CAMH) Clinical Information Transformation project completed multiple preparation steps. An automated process was desired to supplement the onerous task of manual analysis of clinical forms. We used natural language processing (NLP) and machine learning (ML) methods for a series of 266 separate clinical forms. For the investigation, documents were represented by feature vectors. We used four ML algorithms for our examination of the forms: cluster analysis, k-nearest neigh-bours (kNN), decision trees and support vector machines (SVM). Parameters for each algorithm were optimized. SVM had the best performance with a precision of 64.6%. Though we did not find any method sufficiently accurate for practical use, to our knowledge this approach to forms has not been used previously in mental health.

  20. Identifying complications of interventional procedures from UK routine healthcare databases: a systematic search for methods using clinical codes.

    Science.gov (United States)

    Keltie, Kim; Cole, Helen; Arber, Mick; Patrick, Hannah; Powell, John; Campbell, Bruce; Sims, Andrew

    2014-11-28

    Several authors have developed and applied methods to routine data sets to identify the nature and rate of complications following interventional procedures. But, to date, there has been no systematic search for such methods. The objective of this article was to find, classify and appraise published methods, based on analysis of clinical codes, which used routine healthcare databases in a United Kingdom setting to identify complications resulting from interventional procedures. A literature search strategy was developed to identify published studies that referred, in the title or abstract, to the name or acronym of a known routine healthcare database and to complications from procedures or devices. The following data sources were searched in February and March 2013: Cochrane Methods Register, Conference Proceedings Citation Index - Science, Econlit, EMBASE, Health Management Information Consortium, Health Technology Assessment database, MathSciNet, MEDLINE, MEDLINE in-process, OAIster, OpenGrey, Science Citation Index Expanded and ScienceDirect. Of the eligible papers, those which reported methods using clinical coding were classified and summarised in tabular form using the following headings: routine healthcare database; medical speciality; method for identifying complications; length of follow-up; method of recording comorbidity. The benefits and limitations of each approach were assessed. From 3688 papers identified from the literature search, 44 reported the use of clinical codes to identify complications, from which four distinct methods were identified: 1) searching the index admission for specified clinical codes, 2) searching a sequence of admissions for specified clinical codes, 3) searching for specified clinical codes for complications from procedures and devices within the International Classification of Diseases 10th revision (ICD-10) coding scheme which is the methodology recommended by NHS Classification Service, and 4) conducting manual clinical

  1. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  2. Real-Time, Interactive Echocardiography Over High-Speed Networks: Feasibility and Functional Requirements

    Science.gov (United States)

    Bobinsky, Eric A.

    1998-01-01

    Real-time, Interactive Echocardiography Over High Speed Networks: Feasibility and Functional Requirements is an experiment in advanced telemedicine being conducted jointly by the NASA Lewis Research Center, the NASA Ames Research Center, and the Cleveland Clinic Foundation. In this project, a patient undergoes an echocardiographic examination in Cleveland while being diagnosed remotely by a cardiologist in California viewing a real-time display of echocardiographic video images transmitted over the broadband NASA Research and Education Network (NREN). The remote cardiologist interactively guides the sonographer administering the procedure through a two-way voice link between the two sites. Echocardiography is a noninvasive medical technique that applies ultrasound imaging to the heart, providing a "motion picture" of the heart in action. Normally, echocardiographic examinations are performed by a sonographer and cardiologist who are located in the same medical facility as the patient. The goal of telemedicine is to allow medical specialists to examine patients located elsewhere, typically in remote or medically underserved geographic areas. For example, a small, rural clinic might have access to an echocardiograph machine but not a cardiologist. By connecting this clinic to a major metropolitan medical facility through a communications network, a minimally trained technician would be able to carry out the procedure under the supervision and guidance of a qualified cardiologist.

  3. Clinical and linkage study of a large family with simple ectopia lentis linked to FBN1

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, M.J.; Roberts, J.; Partington, M.W. [Newcastle and Northern New South Wales Genetics Service (Australia); Colley, P.W. [John Hunter Hospital, Newcastle (Australia); Hollway, G.E.; Kozman, H.M.; Mulley, J.C. [Adelaide Children`s Hospital, North Adelaide (Australia)

    1994-10-15

    Simple ectopia lentis (EL) was studied in a large family, by clinical examination and analysis of linkage to markers in the region of FBN1, the gene for fibrillin which causes Marfan syndrome on chromosome 15. No patient had clinical or echocardiographic evidence of Marfan syndrome, although there was a trend towards relatively longer measurements of height; lower segment; arm span; middle finger, hand, and foot length in the affected members of the family, compared with unaffected sibs of the same sex. Analysis of linkage to intragenic FBN1 markers was inconclusive because they were relatively uninformative. Construction of a multipoint background map from the CEPH reference families identified microsatellite markers linked closely to FBN1 which could demonstrate linkage of EL in this family to the FBN1 region. LINKMAP analysis detected a multipoint lod score of 5.68 at D15S119, a marker approximately 6 cM distal to FBN1, and a multipoint lod score of 5.04 at FBN1. The EL gene in this family is likely to be allelic to Marfan syndrome, and molecular characterization of the FBN1 mutation should now be possible. 25 refs., 6 figs., 2 tabs.

  4. Blind Source Parameters for Performance Evaluation of Despeckling Filters

    Directory of Open Access Journals (Sweden)

    Nagashettappa Biradar

    2016-01-01

    Full Text Available The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI, and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink embedded with Stein’s unbiased risk estimation (SURE. The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  5. Blind Source Parameters for Performance Evaluation of Despeckling Filters.

    Science.gov (United States)

    Biradar, Nagashettappa; Dewal, M L; Rohit, ManojKumar; Gowre, Sanjaykumar; Gundge, Yogesh

    2016-01-01

    The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI), and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink) embedded with Stein's unbiased risk estimation (SURE). The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  6. Feasibility of Incorporating Alternative Teaching Methods into Clinical Clerkships.

    Science.gov (United States)

    Berman, Judith; And Others

    1990-01-01

    A study investigated the effectiveness of computer-assisted instruction, interactive video, and videotapes as alternative methods of instruction in clinical clerkship modules on diabetes and hypertension. The 17 participants were more interested in balancing time between patient contact and alternative teaching methods and had better knowledge,…

  7. Echocardiographic Diagnostics of Myocardial Infarction in Newborns

    Directory of Open Access Journals (Sweden)

    G. V. Revunenkov

    2015-01-01

    Full Text Available Early and correct diagnostics of myocardial infarction in newborns is impossible without modern instrumental methods, among which echocardiography is the leading one. Hypokinesia, akinesia or dyskinesia of local segments of the heart ventricular wall is determined with echocardiography. We examined a 3-days-old baby with circulatory failure requiring cardiotonic support. On auscultation there was a heart murmur. It was an intracardiac conduction disoder and infarction-like changes on ECG, however, a convincing evidence to interpret the patient’s condition as myocardial infarction has not been received. Therefore, it was decided to conduct echocardiography. According to the results of echocardiography the presence of hyperechogenic diskinetic locus in the apical segment of the right ventricle (post-infarction scar, a local pericardial effusion in the same projection, hyperechogenic movable mass (thrombus in the apical segment of the right ventricle were determined that together with the results of the ECG allowed us to set diagnosis myocardial infarction. Transthoracic echocardiography is one of highly informative methods; the data obtained allowed to correctly interpret the clinical picture of heart failure and to reveal the cause of the patien’st dependance on cardiotonic support.

  8. Asian Americans and Cancer Clinical Trials: A Mixed-Methods Approach to Understanding Awareness and Experience

    Science.gov (United States)

    Paterniti, Debora A.; Chen, Moon S.; Chiechi, Christine; Beckett, Laurel A.; Horan, Nora; Turrell, Corinne; Smith, Ligaya; Morain, Claudia; Montell, Lisa; Gonzalez, Jose Luis; Davis, Sharon; Lara, Primo N.

    2006-01-01

    Cancer clinical trials have been based on low accrual rates. Barriers to recruitment of minority populations affect the generalizability and impact of trial findings for those populations. The authors undertook a mixed-methods approach to understanding levels of awareness and experiences with cancer clinical trials. A survey was administered to new cancer patients and their caretakers (family, close friends, or other social support) at outpatient oncology clinics. Field observations of the trial accrual process also were conducted by employing the grounded theory approach in qualitative methods. Comparison of survey results for Asian-American respondents and non-Asian respondents indicated that Asians were less likely to have heard the term “clinical trial” and were more likely to define a clinical trial as “an experiment” or “a test procedure in a clinic” than non-Asians. Asians were more likely to have employer-based insurance and to report understanding issues related to cost reimbursement. Asians were less likely to have been involved in or to know someone in a trial and reported less willingness than white respondents to consider trial participation. Qualitative observations suggested that Asians who presented for a potential trial were interested in the availability of a novel cancer therapy but were not eligible for available trials. Multiple strategies will be necessary to enhance awareness of and experience with accrual to cancer clinical trials for Asians, including richer understanding and increased involvement of Asians in cancer clinical trials and greater attention to the location and diversity of the Asian population in structuring study centers and evaluating trial results. PMID:16247795

  9. Asymetric septal hypertrophy (ASH): echocardiographic manifestations

    NARCIS (Netherlands)

    F.J. ten Cate (Folkert)

    1978-01-01

    textabstractIn the late fifties and early sixties a distinct clinical entity has been recognized in clinical, hemodynamic and angiocardiographic studies. Since then a burst of information concerning this "cardiomyopathic" disorder has been forthcoming. In this chapter most available information is

  10. Research methods to change clinical practice for patients with rare cancers.

    Science.gov (United States)

    Billingham, Lucinda; Malottki, Kinga; Steven, Neil

    2016-02-01

    Rare cancers are a growing group as a result of reclassification of common cancers by molecular markers. There is therefore an increasing need to identify methods to assess interventions that are sufficiently robust to potentially affect clinical practice in this setting. Methods advocated for clinical trials in rare diseases are not necessarily applicable in rare cancers. This Series paper describes research methods that are relevant for rare cancers in relation to the range of incidence levels. Strategies that maximise recruitment, minimise sample size, or maximise the usefulness of the evidence could enable the application of conventional clinical trial design to rare cancer populations. Alternative designs that address specific challenges for rare cancers with the aim of potentially changing clinical practice include Bayesian designs, uncontrolled n-of-1 trials, and umbrella and basket trials. Pragmatic solutions must be sought to enable some level of evidence-based health care for patients with rare cancers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Clinical guideline representation in a CDS: a human information processing method.

    Science.gov (United States)

    Kilsdonk, Ellen; Riezebos, Rinke; Kremer, Leontien; Peute, Linda; Jaspers, Monique

    2012-01-01

    The Dutch Childhood Oncology Group (DCOG) has developed evidence-based guidelines for screening childhood cancer survivors for possible late complications of treatment. These paper-based guidelines appeared to not suit clinicians' information retrieval strategies; it was thus decided to communicate the guidelines through a Computerized Decision Support (CDS) tool. To ensure high usability of this tool, an analysis of clinicians' cognitive strategies in retrieving information from the paper-based guidelines was used as requirements elicitation method. An information processing model was developed through an analysis of think aloud protocols and used as input for the design of the CDS user interface. Usability analysis of the user interface showed that the navigational structure of the CDS tool fitted well with the clinicians' mental strategies employed in deciding on survivors screening protocols. Clinicians were more efficient and more complete in deciding on patient-tailored screening procedures when supported by the CDS tool than by the paper-based guideline booklet. The think-aloud method provided detailed insight into users' clinical work patterns that supported the design of a highly usable CDS system.

  12. Work-related musculoskeletal disorders in veterinary echocardiographers: a cross-sectional study on prevalence and risk factors.

    Science.gov (United States)

    MacDonald, Kristin; King, Deborah

    2014-03-01

    Assess the relationship between work-related musculoskeletal disorders (WRMSDs) and performing echocardiograms (ECHOS) in veterinarians with a cardiology focus. Prospective study. A survey was submitted to the ACVIM veterinary cardiology list-serve regarding pain associated with performing ECHOS (ECHOPain). Associations of demographic and work habit variables with ECHOPain and WRMSD were evaluated with logistic regression. Respondents included 198 of 487 (41%) members, evenly divided in gender. Most (69%) were 31-50 years old. Almost all (96%) currently perform ECHOS, usually 4-5 ECHOS/week (74%), every week except vacation (93%). ECHOPain was reported by 87 people (44%), which was classified as mild/occasional in 77%, frequent/moderate in 21%, and frequent/severe in 2%. Of those with ECHOPain, 52% reported ECHOS as the sole cause, 31% reported ECHOS aggravating pain from a pre-existing problem, and 17% reported unrelated pain. The most common areas of pain were neck (54%), shoulder (52%), wrist (42%), and back (35%) with 78% reporting pain at 2 or more sites. Pain impaired job performance in 36%, required sick leave or disability in 12%, required reduction in ECHOS/day in 36%, and affected lifestyle in 22%. Ten percent of people have been diagnosed with WRMSD, of which 21% have a permanent disability. Both gender and weeks/year predicted pain with ECHOS (χ(2)(3) = 11.38, P = 0.01). The odds ratio for females versus males with ECHOPain was 2.23. ECHOPain is common (44%) in veterinary echocardiographers, is significantly associated with gender, and affects job performance for over one-third of pain sufferers. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Frontiers of biostatistical methods and applications in clinical oncology

    CERN Document Server

    Crowley, John

    2017-01-01

    This book presents the state of the art of biostatistical methods and their applications in clinical oncology. Many methodologies established today in biostatistics have been brought about through its applications to the design and analysis of oncology clinical studies. This field of oncology, now in the midst of evolution owing to rapid advances in biotechnologies and cancer genomics, is becoming one of the most promising disease fields in the shift toward personalized medicine. Modern developments of diagnosis and therapeutics of cancer have also been continuously fueled by recent progress in establishing the infrastructure for conducting more complex, large-scale clinical trials and observational studies. The field of cancer clinical studies therefore will continue to provide many new statistical challenges that warrant further progress in the methodology and practice of biostatistics. This book provides a systematic coverage of various stages of cancer clinical studies. Topics from modern cancer clinical ...

  14. A comparison of quantitative methods for clinical imaging with hyperpolarized (13)C-pyruvate.

    Science.gov (United States)

    Daniels, Charlie J; McLean, Mary A; Schulte, Rolf F; Robb, Fraser J; Gill, Andrew B; McGlashan, Nicholas; Graves, Martin J; Schwaiger, Markus; Lomas, David J; Brindle, Kevin M; Gallagher, Ferdia A

    2016-04-01

    Dissolution dynamic nuclear polarization (DNP) enables the metabolism of hyperpolarized (13)C-labelled molecules, such as the conversion of [1-(13)C]pyruvate to [1-(13)C]lactate, to be dynamically and non-invasively imaged in tissue. Imaging of this exchange reaction in animal models has been shown to detect early treatment response and correlate with tumour grade. The first human DNP study has recently been completed, and, for widespread clinical translation, simple and reliable methods are necessary to accurately probe the reaction in patients. However, there is currently no consensus on the most appropriate method to quantify this exchange reaction. In this study, an in vitro system was used to compare several kinetic models, as well as simple model-free methods. Experiments were performed using a clinical hyperpolarizer, a human 3 T MR system, and spectroscopic imaging sequences. The quantitative methods were compared in vivo by using subcutaneous breast tumours in rats to examine the effect of pyruvate inflow. The two-way kinetic model was the most accurate method for characterizing the exchange reaction in vitro, and the incorporation of a Heaviside step inflow profile was best able to describe the in vivo data. The lactate time-to-peak and the lactate-to-pyruvate area under the curve ratio were simple model-free approaches that accurately represented the full reaction, with the time-to-peak method performing indistinguishably from the best kinetic model. Finally, extracting data from a single pixel was a robust and reliable surrogate of the whole region of interest. This work has identified appropriate quantitative methods for future work in the analysis of human hyperpolarized (13)C data. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  15. Clinical, serological and echocardiographic examination of healthy field dogs before and after vaccination with a commercial tetravalent leptospirosis vaccine.

    Science.gov (United States)

    Spiri, Andrea M; Rodriguez-Campos, Sabrina; Matos, José M; Glaus, Tony M; Riond, Barbara; Reusch, Claudia E; Hofmann-Lehmann, Regina; Willi, Barbara

    2017-05-25

    Leptospirosis is a re-emerging bacterial zoonosis caused by spirochetes of the genus Leptospira. Severe disease has been reported in dogs in Europe despite vaccination with bivalent Leptospira vaccines. Recently, a tetravalent canine Leptospira vaccine (Nobivac® L4) was licenced in Europe. The goal of this study was to investigate clinical signs, microscopic agglutination test (MAT) titres, haematology, blood biochemistry, cardiac (c) Troponin I levels and echocardiography before and after vaccination with this tetravalent vaccine. Forty-eight healthy dogs were prospectively enrolled and vaccinated twice, 3-4 weeks apart (T0 and T1). Before vaccination (T0) and 16-31 days after the second vaccination (T2), MAT (n = 48), haematology (n = 48), blood biochemistry (n = 36) and cTroponin I measurements (n = 29) were performed, and MAT was repeated 347-413 days after the second vaccination (T3, n = 44). Echocardiography was performed before the first and second vaccination (T0 and T1, n = 24). Mild and transient clinical signs within 5 days following the first and second vaccination occurred in 23% and 10% of the dogs, respectively. Before the first vaccination (T0), all dogs showed negative MAT titres for the tested serovars except for Canicola (50% with titres 100-400). At T2, positive MAT titres to the serovars Canicola (100%), Australis (89%), Grippotyphosa (86%), Bratislava (60%), Autumnalis (58%), Copenhageni (42%), Pomona (12%), Pyrogenes (8%) and Icterohaemorrhagiae (2%) were found. Median to high titres (≥ 400) were most common to the serovar Canicola (92%) and less common to the serovars Australis (41%), Grippotyphosa (21%), Bratislava (12%), Autumnalis (4%), Pyrogenes (4%) and Pomona (2%). At T3, positive MAT titres (titre range: 100-400) were found in 2-18% of the dogs to serovars of the vaccine serogroups and in 2-18% of the dogs to the non-vaccine serovars Pomona, Autumnalis, Pyrogenes and Ballum. Haematology, blood biochemistry, c

  16. An analysis of clinical transition stresses experienced by dental students: A qualitative methods approach.

    Science.gov (United States)

    Botelho, M; Gao, X; Bhuyan, S Y

    2018-04-17

    Stress in dental students is well established with potential psychological distress, emotional exhaustion and burnout-related symptoms. Little attention has been given to the problems encountered by dental students during the transition from theoretical or paraclinical training to the clinical environment. The aim of this study was to adopt a qualitative research methods approach to understand the perceived stressors during students' clinical transition and provide insights for curriculum planners to enhance learning. This study analysed four groups of 2nd- and 3rd-year BDS students' experiences in focus group interviews relating to their pre-clinical and clinical transitions. The interviews were recorded and transcribed verbatim, and a thematic analysis was performed using an inductive qualitative approach. Key overlapping domains identified were the transition gap and stresses. The transition gap was subclassified into knowledge and skill (hard and soft), and stresses was subcategorised into internal and external stresses. On first coming to clinics, students experienced knowledge gaps of unfamiliar clinical treatments with mismatches between knowledge acquisition and clinical exposure. Students felt incompetent owing to the stresses attributable to curriculum design, staff and the patient. This negatively affected their confidence and clinical performance. A range of challenges have been identified that will allow curriculum designer's to plan a more supportive learning experience to help students during their transition to clinical practice giving them timely knowledge, confidence and clinical performance to better prepare them for entering clinics. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. The prognostic significance of atrial fibrillation in heart failure with preserved ejection function: insights from KaRen, a prospective and multicenter study.

    Science.gov (United States)

    Bosseau, Christian; Donal, Erwan; Lund, Lars H; Oger, Emmanuel; Hage, Camilla; Mulak, Geneviève; Daubert, Jean-Claude; Linde, Cecilia

    2017-06-01

    The prognostic value of atrial fibrillation (AF) in heart failure with preserved ejection fraction (HFPEF) remains controversial. We sought to study the prognostic value of AF in a prospective cohort and to characterize the HFPEF patients with AF. KaRen was a prospective, multicenter, international, observational study intended to characterize HFPEF; 538 patients presenting with an acute decompensated cardiac failure and a left ventricular EF > 45% were included. EKG and echocardiogram performed 4-8 week following the index hospitalization were analyzed in core centers. Clinical and echocardiographic characteristics of patients in sinus rhythm vs. with documented AF at enrolment (decompensated HF), upon their 4-8-week visit (in presumed stable clinical condition) and according to patients' cardiac history, were compared. The primary study endpoint was death from any cause or first hospitalization for decompensated heart failure (HF). A total of 413 patients (32% in AF) were analyzed, with a mean follow-up period of 28 months. The patients were primarily elderly individuals (mean age: 76.2 years), with a slight female predominance and a high prevalence of non-cardiovascular comorbidities. The baseline echocardiographic characteristics and the natriuretic peptide levels were indicative of a more severe heart condition among the patients with AF. However, the patients with AF exhibited a similar survival-free interval compared with the patients in sinus rhythm. In this elderly HFPEF population with a high prevalence of non-cardiovascular comorbidities, the presence of AF was not associated with a worse prognosis despite impaired clinical and echocardiographic features.ClinicalTrials.gov: NCT00774709.

  18. The Sherlock Holmes method in clinical practice.

    Science.gov (United States)

    Sopeña, B

    2014-04-01

    This article lists the integral elements of the Sherlock Holmes method, which is based on the intelligent collection of information through detailed observation, careful listening and thorough examination. The information thus obtained is analyzed to develop the main and alternative hypotheses, which are shaped during the deductive process until the key leading to the solution is revealed. The Holmes investigative method applied to clinical practice highlights the advisability of having physicians reason through and seek out the causes of the disease with the data obtained from acute observation, a detailed review of the medical history and careful physical examination. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  19. Whipple's disease. Report of five cases with different clinical features.

    Science.gov (United States)

    Ferrari, M de L; Vilela, E G; Faria, L C; Couto, C A; Salgado, C J; Leite, V R; Brasileiro Filho, G; Bambirra, E A; Mendes, C M; Carvalho, S de C; de Oliveira, C A; da Cunha, A S

    2001-01-01

    Whipple's disease (WD) is a rare systemic disease of infectious etiology which involves the small intestine but can virtually affect any organ. We present here five cases (four males and one female) ranging in age from 20 to 59 years. All patients had intestinal involvement associated or not with clinical manifestations linked to this organ. Vegetation in the tricuspid valve was observed in one patient, suggesting endocarditis caused by Tropheryma whippelii, with disappearance of the echocardiographic alterations after treatment. In one of the male patients the initial clinical manifestation was serologically negative spondylitis, with no diarrhea occurring at any time during follow-up. Ocular involvement associated with intestinal malabsorption and significant weight loss were observed in one case. In the other two cases, diarrhea was the major clinical manifestation. All patients were diagnosed by histological examination of the jejunal mucosa and, when indicated, of extraintestinal tissues by light and electron microscopy. After antibiotic treatment, full remission of symptoms occurred in all cases. A control examination of the intestinal mucosa performed after twelve months of treatment with sulfamethoxazole-trimethoprim revealed the disappearance of T. whippelii in four patients. The remaining patient was lost to follow-up.

  20. Whipple's disease. Report of five cases with different clinical features

    Directory of Open Access Journals (Sweden)

    FERRARI Maria de Lourdes de Abreu

    2001-01-01

    Full Text Available Whipple's disease (WD is a rare systemic disease of infectious etiology which involves the small intestine but can virtually affect any organ. We present here five cases (four males and one female ranging in age from 20 to 59 years. All patients had intestinal involvement associated or not with clinical manifestations linked to this organ. Vegetation in the tricuspid valve was observed in one patient, suggesting endocarditis caused by Tropheryma whippelii, with disappearance of the echocardiographic alterations after treatment. In one of the male patients the initial clinical manifestation was serologically negative spondylitis, with no diarrhea occurring at any time during follow-up. Ocular involvement associated with intestinal malabsorption and significant weight loss were observed in one case. In the other two cases, diarrhea was the major clinical manifestation. All patients were diagnosed by histological examination of the jejunal mucosa and, when indicated, of extraintestinal tissues by light and electron microscopy. After antibiotic treatment, full remission of symptoms occurred in all cases. A control examination of the intestinal mucosa performed after twelve months of treatment with sulfamethoxazole-trimethoprim revealed the disappearance of T. whippelii in four patients. The remaining patient was lost to follow-up.

  1. Improved modeling of clinical data with kernel methods.

    Science.gov (United States)

    Daemen, Anneleen; Timmerman, Dirk; Van den Bosch, Thierry; Bottomley, Cecilia; Kirk, Emma; Van Holsbeke, Caroline; Valentin, Lil; Bourne, Tom; De Moor, Bart

    2012-02-01

    Despite the rise of high-throughput technologies, clinical data such as age, gender and medical history guide clinical management for most diseases and examinations. To improve clinical management, available patient information should be fully exploited. This requires appropriate modeling of relevant parameters. When kernel methods are used, traditional kernel functions such as the linear kernel are often applied to the set of clinical parameters. These kernel functions, however, have their disadvantages due to the specific characteristics of clinical data, being a mix of variable types with each variable its own range. We propose a new kernel function specifically adapted to the characteristics of clinical data. The clinical kernel function provides a better representation of patients' similarity by equalizing the influence of all variables and taking into account the range r of the variables. Moreover, it is robust with respect to changes in r. Incorporated in a least squares support vector machine, the new kernel function results in significantly improved diagnosis, prognosis and prediction of therapy response. This is illustrated on four clinical data sets within gynecology, with an average increase in test area under the ROC curve (AUC) of 0.023, 0.021, 0.122 and 0.019, respectively. Moreover, when combining clinical parameters and expression data in three case studies on breast cancer, results improved overall with use of the new kernel function and when considering both data types in a weighted fashion, with a larger weight assigned to the clinical parameters. The increase in AUC with respect to a standard kernel function and/or unweighted data combination was maximum 0.127, 0.042 and 0.118 for the three case studies. For clinical data consisting of variables of different types, the proposed kernel function--which takes into account the type and range of each variable--has shown to be a better alternative for linear and non-linear classification problems

  2. Measurement properties of exsisting clinical assessment methods evaluating scapular positioning and function. A systematic review

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Juul-Kristensen, B; Lund, H

    (COSMIN checklist), the methodological quality in the reliability and validity domains was ‘fair’ (57%) to ‘poor’ (43%), with only one study rated as ‘good’. The reliability domain was most often investigated. Fewof the assessment methods in the included studies that had ‘fair’ or ‘good’ measurement......MEASUREMENT PROPERTIES OF EXISTING CLINICAL ASSESSMENT METHODS EVALUATING SCAPULAR POSITIONING AND FUNCTION. A SYSTEMATIC REVIEW1,2Camilla Marie Larsen, 1,3Birgit Juul-Kristensen, 1,3Hans Lund, 1Karen Søgaard1Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark2......,2]. Rehabilitation exercises are aiming at altering abnormal/asymmetric scapular positioning and/or function. Numerous assessment methods have measured the degree of scapular dyskinesis, subjectively by visual evaluation and objectively by measurements of static and dynamic scapular positioning, by either a 3...

  3. Associations between cardiac pathology and clinical, echocardiographic and electrocardiographic findings in dogs with chronic congestive heart failure

    DEFF Research Database (Denmark)

    Falk, Bo Torkel; Jönsson, Lennart; Olsen, Lisbeth Høier

    2010-01-01

    The objective of this study was to correlate defined pathological features with clinical findings in dogs with naturally occurring congestive heart failure (CHF). Fifty-eight dogs with CHF were examined clinically and using echocardiography and electrocardiography. Detailed cardiac post...... such as MMVD, myocardial atrophy and fibrosis, and by arteriosclerosis. Further, more extensive research will be required to establish cause-effect relationships between these cardiac lesions and the pathophysiology of CHF in dogs....

  4. Alterações ecocardiográficas em doentes asmáticos Echocardiograph alterations in asthma patients

    Directory of Open Access Journals (Sweden)

    André Luís Mancini

    2008-06-01

    Full Text Available Introdução: A asma é uma doença inflamatória crónica cuja prevalência vem aumentando nos últimos 20 anos. Demanda grande utilização de recursos, principalmente no grupo grave. Neste, há consumo crónico de corticóides inalatórios e de β2-agonistas, que podem produzir uma série de problemas. O objectivo deste trabalho é o de rastrear as alterações electro e ecocardiográficas e relacioná-las ao grau da asma. Metodologia: Selecionámos 87 doentes do ambulatório de asma do HUGG, que, por rotina, possuem uma espirografia, um eletrocardiograma (ECG e um ecocardiograma (ECO feitos com um intervalo máximo de um mês. As alterações ecocardiográficas encontradas foram relacionadas com o grau da asma. Foram usadas estatísticas não paramétricas para essas comparações. Resultados: Encontrámos diferenças significativas (p≤ 0,05 quanto à idade, tempo de asma e saturação da hemoglobina (SaO2 entre os grupos leve e grave. Na amostra, foi identificada alta prevalência de insuficiência tricúspide (41,4%. Conclusões: O ECO identificou uma série de anormalidades, dependentes ou não da gravidade da asma. O ECO pode identificar a hipertensão arterial pulmonar, pelo cálculo da pressão média da artéria pulmonar.Introduction: Asthma is a chronic inflammatory disease which has increased during the last 20 years, putting a strain on medical resources, particularly severe forms of the disease. Treatment in such cases is inhaled corticosteroids and beta agonist drugs that can produce a range of side effects. The aim of this study is to identify echocardiograph abnormalities and correlate them with severity of disease. Methodology: Eight-seven outpatients were selected at the asthma unit of the Gaffrée Guinle University Hospital (HUGG. Each patient underwent spirometry, electrocardiogram (ECG and echocardiogram (ECO during the trial within a month maximum. Echocardiograph abnormalities found related to degree of asthma

  5. Doctors' use of mobile devices in the clinical setting: a mixed methods study.

    Science.gov (United States)

    Nerminathan, Arany; Harrison, Amanda; Phelps, Megan; Alexander, Shirley; Scott, Karen M

    2017-03-01

    Mobile device use has become almost ubiquitous in daily life and therefore includes use by doctors in clinical settings. There has been little study as to the patterns of use and impact this has on doctors in the workplace and how negatively or positively it impacts at the point of care. To explore how doctors use mobile devices in the clinical setting and understand drivers for use. A mixed methods study was used with doctors in a paediatric and adult teaching hospital in 2013. A paper-based survey examined mobile device usage data by doctors in the clinical setting. Focus groups explored doctors' reasons for using or refraining from using mobile devices in the clinical setting, and their attitudes about others' use. The survey, completed by 109 doctors, showed that 91% owned a smartphone and 88% used their mobile devices frequently in the clinical setting. Trainees were more likely than consultants to use their mobile devices for learning and accessing information related to patient care, as well as for personal communication unrelated to work. Focus group data highlighted a range of factors that influenced doctors to use personal mobile devices in the clinical setting, including convenience for medical photography, and factors that limited use. Distraction in the clinical setting due to use of mobile devices was a key issue. Personal experience and confidence in using mobile devices affected their use, and was guided by role modelling and expectations within a medical team. Doctors use mobile devices to enhance efficiency in the workplace. In the current environment, doctors are making their own decisions based on balancing the risks and benefits of using mobile devices in the clinical setting. There is a need for guidelines around acceptable and ethical use that is patient-centred and that respects patient privacy. © 2016 Royal Australasian College of Physicians.

  6. Left atrioventricular remodeling in the assessment of the left ventricle diastolic function in patients with heart failure: a review of the currently studied echocardiographic variables

    Directory of Open Access Journals (Sweden)

    Köhler Ilmar

    2008-11-01

    Full Text Available Abstract Multiparametric echocardiographic imaging of the failing heart is now increasingly used and useful in decision making in heart failure. The reasons for this, relies on the need of different strategies of handling these patients, as differentiation of systolic or diastolic dysfunction, as well as on the gamma of approaches available, such as percutaneous and surgical revascularization, devices implantations, and valvular regurgitations and stenosis corrections. Congestive heart failure in patients with normal left ventricular diameters or preserved left ventricular ejection fraction had been pointed out recently as present in a proportion so high as 40 to 50 percent of cases of heart failure, mainly due to the epidemics in well developed countries, as is the problem of not well controlled metabolic states (such as obesity and diabetes, but also due to the real word in developing countries, as is the case of hypertension epidemics and its lack of adequate control. As a matter of public utility, the guidelines in the diagnosis and treatment of such patients will have to be cheap, available, easily reproducible, and ideally will furnish answers for the clinician questions not in a binary "black or white" manner, but with graduations, so if possible it has to be quantitative. The present paper aim to focus on the current clinical applications of tissue Doppler and of left atrial function and remodeling, and its pathophysiologic relationship with the left ventricle, as will be cleared in the documented review of echocardiography that follows, considering that the need of universal data on the syndrome of the failing heart does not mean, unfortunately, that all patients and clinicians in developing countries have at their own health facilities the same imaging tools, since they are, as a general rule, expensive.

  7. Indicators of surgical treatment of patent ductus arteriosus in preterm neonates in the first week of life

    OpenAIRE

    Braulio, Renato; Gelape, Cláudio Léo; Araújo, Fátima Derlene da Rocha; Brandão, Kelly Nascimento; Abreu, Luciana Drummond Guimarães; Costa, Paulo Henrique Nogueira; Capanema, Flávio Diniz

    2013-01-01

    OBJECTIVE: To identify clinical and echocardiographic indicators of the necessity for early surgical closure of patent ductus arteriosus in preterm neonates. METHODS: The prospective study was conducted at the Neonatal Unit of Hospital Municipal Odilon Behrens between 2006 and 2010. The study population comprised 115 preterm neonates diagnosed with patent ductus arteriosus in the first week after birth, of whom 55 (group S) were submitted to clinical and or surgical closure and 60 (group NS) ...

  8. Early Clinical Outcomes of Tricuspid Valve Repair with a Tri-Ad Annuloplasty Ring in Comparison with the Outcomes Using an MC³ Ring

    Directory of Open Access Journals (Sweden)

    Woohyun Jung

    2018-04-01

    Full Text Available Background: We evaluated the early clinical outcomes of tricuspid valve annuloplasty (TAP with the Tri-Ad annuloplasty ring for functional tricuspid regurgitation (TR. Methods: From January 2015 to March 2017, 36 patients underwent TAP with a Tri-Ad ring for functional TR. To evaluate the early clinical outcomes of TAP with the Tri-Ad ring, we conducted a propensity score-matched analysis comparing the Tri-Ad and MC³ tri-cuspid annuloplasty rings (n=34 in each group. The follow-up duration was 11.0±7.07 months. Results: There was 1 case of operative mortality (2.8% and no cases of late mortality. Postoperative complications occurred in 15 patients (41%, including acute kidney injury in 6 patients (16%, bleeding requiring reoperation in 4 patients (11%, and low cardiac output syndrome in 4 patients (11%. There were no ring-related complications, such as atrioventricular block or ring dehiscence. The TR grade decreased significantly (from 2.03±1.06 to 1.18±0.92, p<0.01, as did the systolic pulmonary artery pressure (from 43.53±13.84 to 38.00±9.72 mm Hg, p=0.03. There were no cases of severe residual TR, but moderate TR was observed in 3 patients, all of whom had severe TR preoperatively. Severe preoperative TR was also associated with moderate in the univariate analysis (p<0.01. In the propensity score-matched analysis comparing the Tri-Ad and MC³ rings, there was no significant difference in early clinical outcomes. Conclusion: TAP with the Tri-Ad ring corrected functional TR effectively and provided good early clinical and echocardiographic results without ring-related complications. However, severe preoperative TR was associated with moderate or severe residual TR in the immediate postoperative period. A follow-up study is necessary to confirm the stability of this procedure.

  9. "Unscrambling what's in your head": A mixed method evaluation of clinical supervision for midwives.

    Science.gov (United States)

    Love, Bev; Sidebotham, Mary; Fenwick, Jennifer; Harvey, Susan; Fairbrother, Greg

    2017-08-01

    As a strategy to promote workforce sustainability a number of midwives working in one health district in New South Wales, Australia were trained to offer a reflective model of clinical supervision. The expectation was that these midwives would then be equipped to facilitate clinical supervision for their colleagues with the organisational aim of supporting professional development and promoting emotional well-being. To identify understanding, uptake, perceptions of impact, and the experiences of midwives accessing clinical supervision. Mixed Methods. In phase one 225 midwives were invited to complete a self-administered survey. Descriptive and inferential statistics were used to analyse the data. In phase two 12 midwives were interviewed. Thematic analysis was used to deepen understanding of midwives' experiences of receiving clinical supervision. Sixty percent of midwives responding in phase one had some experience of clinical supervision. Findings from both phases were complementary with midwives reporting a positive impact on their work, interpersonal skills, situational responses and career goals. Midwives described clinical supervision as a formal, structured and confidential space for 'safe reflection' that was valued as an opportunity for self-care. Barriers included misconceptions, perceived work related pressures and a sense that taking time out was unjustifiable. Education, awareness raising and further research into reflective clinical supervision, to support emotional well-being and professional midwifery practice is needed. In addition, health organisations need to design, implement and evaluate strategies that support the embedding of clinical supervision within midwives' clinical practice. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  10. Using mixed methods to identify and answer clinically relevant research questions.

    Science.gov (United States)

    Shneerson, Catherine L; Gale, Nicola K

    2015-06-01

    The need for mixed methods research in answering health care questions is becoming increasingly recognized because of the complexity of factors that affect health outcomes. In this article, we argue for the value of using a qualitatively driven mixed method approach for identifying and answering clinically relevant research questions. This argument is illustrated by findings from a study on the self-management practices of cancer survivors and the exploration of one particular clinically relevant finding about higher uptake of self-management in cancer survivors who had received chemotherapy treatment compared with those who have not. A cross-sectional study generated findings that formed the basis for the qualitative study, by informing the purposive sampling strategy and generating new qualitative research questions. Using a quantitative research component to supplement a qualitative study can enhance the generalizability and clinical relevance of the findings and produce detailed, contextualized, and rich answers to research questions that would be unachievable through quantitative or qualitative methods alone. © The Author(s) 2015.

  11. Tracing the evolution of chiropractic students' confidence in clinical and patient communication skills during a clinical internship: a multi-methods study.

    Science.gov (United States)

    Hecimovich, Mark; Volet, Simone

    2012-06-19

    Anecdotal evidence points to variations in individual students' evolving confidence in clinical and patient communication skills during a clinical internship. A better understanding of the specific aspects of internships that contribute to increasing or decreasing confidence is needed to best support students during the clinical component of their study. A multi-method approach, combining two large-scale surveys with 269 students and three in-depth individual interviews with a sub-sample of 29 students, was used to investigate the evolution of change in student confidence during a 10-month long internship. Change in levels of confidence in patient communication and clinical skills was measured and relationship to demographic factors were explored. The interviews elicited students' accounts and reflections on what affected the evolution of their confidence during the internship. At the start of their internship, students were more confident in their patient communication skills than their clinical skills but prior experience was significantly related to confidence in both. Initial confidence in patient communication skills was also related to age and prior qualification but not gender whilst confidence in clinical skills was related to gender but not age or prior qualification. These influences were maintained over time. Overall, students' levels of confidence in patient communication and clinical skills confidence increased significantly over the duration of the internship with evidence that change over time in these two aspects were inter-related. To explore how specific aspects of the internship contributed to changing levels of confidence, two extreme sub-groups of interviewees were identified, those with the least increase and those with the highest increase in professional confidence over time. A number of key factors affecting the development of confidence were identified, including among others, interactions with clinicians and patients, personal agency and

  12. Methodical principles of assessment of financial compensation for clinical trial volunteer participants

    Directory of Open Access Journals (Sweden)

    V. Ye. Dobrova

    2013-10-01

    Full Text Available Introduction. Due to the necessity to obtain the reliable results of a clinical trial and to distribute it to the general population of patients the problem of recruiting the adequate number of individuals to participate in the study as objects of observation in the group receiving the investigational medicinal product or as a member of the control group should to be solved. Aim of study. The aim of our study was to research and to justify practically the methodological approaches to determining financial compensation for participation of volunteers in the clinical trials and the appropriate methods of its calculation. Material and methods. For the purpose of determining the baseline factors for calculating the hourly compensation the survey of healthy volunteers and of expert professionals as well as the analysis of its results have been done. Questioning healthy volunteers regarding their attitudes towards inconvenience and discomfort during participation in clinical trials was held at the Ukrainian clinical research centers. Survey participants number was 99, they were healthy volunteers who took part in the first phase clinical trial or bioequivalence studies. The expert survey included questioning of the 193 professionals from Ukrainian clinical research centers, CRO, pharmaceutical manufacturers – research sponsors and collaborators State Expert Center Ministry of Health of Ukraine, who were involved in the planning, organization, implementation and evaluation of clinical trials as well as their regulatory control. Results of study. Using the method of pairwise comparisons and iterative refinement procedures the collective estimate of experts questionnaire results has been performed, by the results of which the nine indicators have been identified and the importance of each of them as units of discomfort have been established. Motivational factors of voluntary participation in clinical trials have been studied. Motivation system for

  13. cp-R, an interface the R programming language for clinical laboratory method comparisons.

    Science.gov (United States)

    Holmes, Daniel T

    2015-02-01

    Clinical scientists frequently need to compare two different bioanalytical methods as part of assay validation/monitoring. As a matter necessity, regression methods for quantitative comparison in clinical chemistry, hematology and other clinical laboratory disciplines must allow for error in both the x and y variables. Traditionally the methods popularized by 1) Deming and 2) Passing and Bablok have been recommended. While commercial tools exist, no simple open source tool is available. The purpose of this work was to develop and entirely open-source GUI-driven program for bioanalytical method comparisons capable of performing these regression methods and able to produce highly customized graphical output. The GUI is written in python and PyQt4 with R scripts performing regression and graphical functions. The program can be run from source code or as a pre-compiled binary executable. The software performs three forms of regression and offers weighting where applicable. Confidence bands of the regression are calculated using bootstrapping for Deming and Passing Bablok methods. Users can customize regression plots according to the tools available in R and can produced output in any of: jpg, png, tiff, bmp at any desired resolution or ps and pdf vector formats. Bland Altman plots and some regression diagnostic plots are also generated. Correctness of regression parameter estimates was confirmed against existing R packages. The program allows for rapid and highly customizable graphical output capable of conforming to the publication requirements of any clinical chemistry journal. Quick method comparisons can also be performed and cut and paste into spreadsheet or word processing applications. We present a simple and intuitive open source tool for quantitative method comparison in a clinical laboratory environment. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Thinking lean: implementing DMAIC methods to improve efficiency within a cystic fibrosis clinic.

    Science.gov (United States)

    Smith, Chad; Wood, Suzanne; Beauvais, Bradley

    2011-01-01

    The timely coordination of care in clinics that require frequent assessments by multiple specialists can be challenging for both patients and providers. The cornerstone of care at cystic fibrosis (CF) centers with superior clinical outcomes, as with reduced acuity of episodic disease and incidence of hospitalizations, is frequent clinical encounters coupled with aggressive therapies. However, inefficiencies in the clinical practice structure prevent optimal utilization of resources. To decrease non-value-added time, defined as time a patient spends alone in an examination room, without altering the time providers spend caring for a patient, the application of Lean methods was used to see whether reducing variation could significantly decrease lead time, considered the length of a patient visit, within a CF clinic setting. Baseline capability analyses revealed only 19.3% of patient visits were completed in 60min or less, with mean and median visit times of 84 and 81min, respectively. Final capability analyses demonstrated that 41.5% of patient visits were completed in 60min or less, 23% greater than the baseline capability. Mean and median visit times decreased by 10min per visit. Research efforts increased the available capacity by 500 patient visits per year, representing additional revenue of over US$165,000 annually with no additional administrative costs incurred. © 2011 National Association for Healthcare Quality.

  15. Monitoring progression of clinical reasoning skills during health sciences education using the case method - a qualitative observational study.

    Science.gov (United States)

    Orban, Kristina; Ekelin, Maria; Edgren, Gudrun; Sandgren, Olof; Hovbrandt, Pia; Persson, Eva K

    2017-09-11

    Outcome- or competency-based education is well established in medical and health sciences education. Curricula are based on courses where students develop their competences and assessment is also usually course-based. Clinical reasoning is an important competence, and the aim of this study was to monitor and describe students' progression in professional clinical reasoning skills during health sciences education using observations of group discussions following the case method. In this qualitative study students from three different health education programmes were observed while discussing clinical cases in a modified Harvard case method session. A rubric with four dimensions - problem-solving process, disciplinary knowledge, character of discussion and communication - was used as an observational tool to identify clinical reasoning. A deductive content analysis was performed. The results revealed the students' transition over time from reasoning based strictly on theoretical knowledge to reasoning ability characterized by clinical considerations and experiences. Students who were approaching the end of their education immediately identified the most important problem and then focused on this in their discussion. Practice knowledge increased over time, which was seen as progression in the use of professional language, concepts, terms and the use of prior clinical experience. The character of the discussion evolved from theoretical considerations early in the education to clinical reasoning in later years. Communication within the groups was supportive and conducted with a professional tone. Our observations revealed progression in several aspects of students' clinical reasoning skills on a group level in their discussions of clinical cases. We suggest that the case method can be a useful tool in assessing quality in health sciences education.

  16. Clinical and cardiovascular alterations produced by scorpion envenomation in dogs

    Directory of Open Access Journals (Sweden)

    F. F. Cordeiro

    2006-01-01

    Full Text Available Scorpionism is a common problem that occurs in tropical and subtropical countries and assumes great medical-sanitary importance due to its fatal effect on sensitive individuals, being able to lead children and aged people to death. The envenomation lethal potential is responsible for the serious cardiopulmonary alterations the scorpion toxin produces in its victims. The present research evaluated the effects of Tityus serrulatus venom on dogs, using two distinct doses: a dose that simulates natural envenomation (0.4 mg/total dose, and an experimental dose (0.25 mg/kg. General clinical signs were observed at different moments after envenomation, and specific data related to the cardiopulmonary system were evaluated by systemic arterial pressure measurement, CK-MB enzymatic activity dosage, and radiographic, electrocardiographic and echocardiographic examinations. Results demonstrated that the scorpion venom, in experimental doses, was able to cause acute and reversible cardiac injury in few days, and, in the dose that simulated natural accident, it produced clinical signs of light envenomation, such as local pain, hyperesthesia, sialorrhea, vomiting, diarrhea, sneeze and prostration.

  17. Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.

    Science.gov (United States)

    Samad, Zainab; Minter, Stephanie; Armour, Alicia; Tinnemore, Amanda; Sivak, Joseph A; Sedberry, Brenda; Strub, Karen; Horan, Seanna M; Harrison, J Kevin; Kisslo, Joseph; Douglas, Pamela S; Velazquez, Eric J

    2016-03-01

    The management of aortic stenosis rests on accurate echocardiographic diagnosis. Hence, it was chosen as a test case to examine the utility of continuous quality improvement (CQI) approaches to increase echocardiographic data accuracy and reliability. A novel, multistep CQI program was designed and prospectively used to investigate whether it could minimize the difference in aortic valve mean gradients reported by echocardiography when compared with cardiac catheterization. The Duke Echo Laboratory compiled a multidisciplinary CQI team including 4 senior sonographers and MD faculty to develop a mapped CQI process that incorporated Intersocietal Accreditation Commission standards. Quarterly, the CQI team reviewed all moderate- or greater-severity aortic stenosis echocardiography studies with concomitant catheterization data, and deidentified individual and group results were shared at meetings attended by cardiologists and sonographers. After review of 2011 data, the CQI team proposed specific amendments implemented over 2012: the use of nontraditional imaging and Doppler windows as well as evaluation of aortic gradients by a second sonographer. The primary outcome measure was agreement between catheterization- and echocardiography-derived mean gradients calculated by using the coverage probability index with a prespecified acceptable echocardiography-catheterization difference of <10 mm Hg in mean gradient. Between January 2011 and January 2014, 2093 echocardiograms reported moderate or greater aortic stenosis. Among cases with available catheterization data pre- and post-CQI, the coverage probability index increased from 54% to 70% (P=0.03; 98 cases, year 2011; 70 cases, year 2013). The proportion of patients referred for invasive valve hemodynamics decreased from 47% pre-CQI to 19% post-CQI (P<0.001). A laboratory practice pattern that was amenable to reform was identified, and a multistep modification was designed and implemented that produced clinically

  18. Feasibility of a shorter Goal Attainment Scaling method for a pediatric spasticity clinic - The 3-milestones GAS.

    Science.gov (United States)

    Krasny-Pacini, A; Pauly, F; Hiebel, J; Godon, S; Isner-Horobeti, M-E; Chevignard, M

    2017-07-01

    Goal Attainment Scaling (GAS) is a method for writing personalized evaluation scales to quantify progress toward defined goals. It is useful in rehabilitation but is hampered by the experience required to adequately "predict" the possible outcomes relating to a particular goal before treatment and the time needed to describe all 5 levels of the scale. Here we aimed to investigate the feasibility of using GAS in a clinical setting of a pediatric spasticity clinic with a shorter method, the "3-milestones" GAS (goal setting with 3 levels and goal rating with the classical 5 levels). Secondary aims were to (1) analyze the types of goals children's therapists set for botulinum toxin treatment and (2) compare the score distribution (and therefore the ability to predict outcome) by goal type. Therapists were trained in GAS writing and prepared GAS scales in the regional spasticity-management clinic they attended with their patients and families. The study included all GAS scales written during a 2-year period. GAS score distribution across the 5 GAS levels was examined to assess whether the therapist could reliably predict outcome and whether the 3-milestones GAS yielded similar distributions as the original GAS method. In total, 541 GAS scales were written and showed the expected score distribution. Most scales (55%) referred to movement quality goals and fewer (29%) to family goals and activity domains. The 3-milestones GAS method was feasible within the time constraints of the spasticity clinic and could be used by local therapists in cooperation with the hospital team. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Method paper--distance and travel time to casualty clinics in Norway based on crowdsourced postcode coordinates: a comparison with other methods.

    Science.gov (United States)

    Raknes, Guttorm; Hunskaar, Steinar

    2014-01-01

    We describe a method that uses crowdsourced postcode coordinates and Google maps to estimate average distance and travel time for inhabitants of a municipality to a casualty clinic in Norway. The new method was compared with methods based on population centroids, median distance and town hall location, and we used it to examine how distance affects the utilisation of out-of-hours primary care services. At short distances our method showed good correlation with mean travel time and distance. The utilisation of out-of-hours services correlated with postcode based distances similar to previous research. The results show that our method is a reliable and useful tool for estimating average travel distances and travel times.

  20. Method paper--distance and travel time to casualty clinics in Norway based on crowdsourced postcode coordinates: a comparison with other methods.

    Directory of Open Access Journals (Sweden)

    Guttorm Raknes

    Full Text Available We describe a method that uses crowdsourced postcode coordinates and Google maps to estimate average distance and travel time for inhabitants of a municipality to a casualty clinic in Norway. The new method was compared with methods based on population centroids, median distance and town hall location, and we used it to examine how distance affects the utilisation of out-of-hours primary care services. At short distances our method showed good correlation with mean travel time and distance. The utilisation of out-of-hours services correlated with postcode based distances similar to previous research. The results show that our method is a reliable and useful tool for estimating average travel distances and travel times.

  1. High-Sensitivity Troponin: A Clinical Blood Biomarker for Staging Cardiomyopathy in Fabry Disease.

    Science.gov (United States)

    Seydelmann, Nora; Liu, Dan; Krämer, Johannes; Drechsler, Christiane; Hu, Kai; Nordbeck, Peter; Schneider, Andreas; Störk, Stefan; Bijnens, Bart; Ertl, Georg; Wanner, Christoph; Weidemann, Frank

    2016-05-31

    High-sensitivity troponin (hs-TNT), a biomarker of myocardial damage, might be useful for assessing fibrosis in Fabry cardiomyopathy. We performed a prospective analysis of hs-TNT as a biomarker for myocardial changes in Fabry patients and a retrospective longitudinal follow-up study to assess longitudinal hs-TNT changes relative to fibrosis and cardiomyopathy progression. For the prospective analysis, hs-TNT from 75 consecutive patients with genetically confirmed Fabry disease was analyzed relative to typical Fabry-associated echocardiographic findings and total myocardial fibrosis as measured by late gadolinium enhancement (LE) on magnetic resonance imaging. Longitudinal data (3.9±2.0 years), including hs-TNT, LE, and echocardiographic findings from 58 Fabry patients, were retrospectively collected. Hs-TNT level positively correlated with LE (linear correlation coefficient, 0.72; odds ratio, 32.81 [95% CI, 3.56-302.59]; P=0.002); patients with elevated baseline hs-TNT (>14 ng/L) showed significantly increased LE (median: baseline, 1.9 [1.1-3.3] %; follow-up, 3.2 [2.3-4.9] %; PFabry disease and a qualified predictor of cardiomyopathy progression. Thus, hs-TNT could be helpful for staging and follow-up of Fabry patients. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Clinical effect comparison of different surgical methods for treating diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Qing Wu

    2014-12-01

    Full Text Available AIM: To compare the clinical results of different surgical methods for diabetic antipathy. METHODS: Eighty cases(102 eyeswith diabetic antipathy were selected in our hospital from January 2012 to December 2013. Thirty-eight cases(48 eyesin group A received joint surgical treatment, 42 cases(54 eyesin group B took staging of surgical treatment. The clinical effect was observed in both groups.RESULTS: The vision after surgery was improved than that of before surgery in two groups, there were no significant differences(P>0.05. A postoperative complication rate was 16.7% in group A and 22.2% in group B, showed no significant difference(P>0.05. CONCLUSION: Surgery and staging joint surgery are both feasible for diabetic retinopathy patients, can, improve the visionr. Both of them are worthy of clinical application.

  3. Chitotriosidase enzyme activity: is this a possible chronic inflammation marker in children with common variable immunodeficiency and early atherosclerosis?

    Science.gov (United States)

    Azarsız, Elif; Karaca, Neslihan; Levent, Erturk; Kutukculer, Necil; Sozmen, Eser

    2017-11-01

    Background Common variable immunodeficiency is a rare clinically symptomatic primary immunodeficiency disorder which manifests a wide variability of symptoms, complications. Atherosclerosis in common variable immunodeficiency patients has not been investigated yet contrary to other severe clinical complications. We aimed to investigate the chitotriosidase enzyme's role as an inflammation and atherosclerosis marker in paediatric common variable immunodeficiency patients. Methods Common variable immunodeficiency patients (n = 24) and healthy controls (n = 23) evaluated for chitotriosidase activity with other inflammation markers (hsCRP, myeloperoxidase, serum amyloid A, ferritin), lipid profile and echocardiographic findings (carotid artery intima media thickness - cIMT, brachial artery flow-mediated vazodilatation - FMD%). Results In patients, the mean chitotriosidase activity (8.98 ± 6.28) was significantly higher than the controls (5.17 ± 3.42) ( P = 0.014). Chitotriosidase showed positive relation with hs-CRP ( P = 0.011) and SAA ( P = 0.011) but had no relation with ferritin ( P = 0.155), HDL ( P = 0.152) or LDL-cholesterol ( P = 0.380). Mean cIMT increased in patients compared with the controls ( P variable immunodeficiency patients demonstrated in vivo the presence of activated macrophages indicating ongoing inflammation. Echocardiographic diastolic functional deficiency, increased cIMT and decreased FMD% may be accepted as early atherosclerotic findings, but none of them showed relationship with chitotriosidase activities.

  4. Clinical characteristics of the respiratory and cardiovascular systems in patients with combination of chronic obstructive pulmonary disease and heart failure

    Directory of Open Access Journals (Sweden)

    I. I. Vyshnyvetskyy

    2017-06-01

    Full Text Available The aim of our work was to assess the respiratory and cardiovascular systems of patients with a combination of chronic obstructive pulmonary disease (COPD and congestive heart failure (CHF. Materials and methods. The study included 177 patients who had been diagnosed COPD by criteria GOLD. CHF was diagnosed in 77 (43.5 % cases – 29 (16.4 % with reduced systolic function and 48 (27.1 % with preserved systolic function. We analyzed some important parameters characterizing respiratory and cardiovascular systems. We tried to identify statistically significant difference of parameters between patients with COPD and those with COPD and CHF. Moreover, patients with CHF were evaluated as a whole, and separately with reduced and with preserved systolic function. Results. Thus, we observed significant deterioration in general clinical, laboratory, spirometric and echocardiographic parameters depending on the presence and severity of CHF in patients with COPD. In particular, the presence of CHF, especially with impaired systolic function significantly impair indicators such as incidence of cardiac arrhythmias and signs of ischemia on the ECG, NT-proBNP levels, prevalence of concentric, eccentric hypertrophy and concentric LV remodeling and diastolic dysfunction type "relaxation disorder", and incidence of a-wave absence during assessment of motion of the rear pulmonary artery valve wall. Listed changes as well as some of the tendencies that have not reached a certain level of significance, indicate that patients with COPD and concomitant CHF, especially with impaired systolic function, worsens general clinical parameters (breath rate, systolic blood pressure, heart rate, frequency arrhythmias and myocardial ischemia on ECG; laboratory levels of hemoglobin, hematocrit, cholesterol, glomerular filtration rate; spirometric indicators of bronchial obstruction (FEV1, FVC, instant volume expiratory flow rates; echocardiographic indicators suggest the

  5. Histologic characterization of canine dilated cardiomyopathy.

    Science.gov (United States)

    Tidholm, A; Jönsson, L

    2005-01-01

    Dilated cardiomyopathy (DCM), characterized by chamber dilatation and myocardial systolic and diastolic dysfunction, is one of the most common heart diseases in dogs. The clinical diagnosis is based on findings on echocardiographic and Doppler examinations, with the active exclusion of other acquired or congenital heart diseases. However, the echocardiographic criteria for the diagnosis of DCM are not wholly specific for the disease, and histologic examination may be necessary for final diagnosis. Review of reports on histologic findings in dogs with clinically diagnosed DCM reveals two histologically distinct forms of DCM: 1) cardiomyopathy of Boxers and Doberman Pinschers, corresponding to the "fatty infiltration-degenerative" type and 2) the form seen in many giant, large-, and medium-sized breeds, including some Boxers and Doberman Pinschers, classified as the "attenuated wavy fiber" type of DCM. The histologic changes of the attenuated wavy fiber type of DCM may precede clinical and echocardiographic signs of heart disease, thus indicating an early stage of DCM.

  6. Participatory design methods for the development of a clinical telehealth service for neonatal homecare.

    Science.gov (United States)

    Garne Holm, Kristina; Brødsgaard, Anne; Zachariassen, Gitte; Smith, Anthony C; Clemensen, Jane

    2017-01-01

    Neonatal homecare delivered during home visits by neonatal nurses is a common method for supporting families of preterm infants following discharge. Telehealth has been introduced for the provision of neonatal homecare, resulting in positive feedback from parents of preterm infants. While the benefits are beginning to be realised, widespread uptake of telehealth has been limited due to a range of logistical challenges. Understanding user requirements is important when planning and developing a clinical telehealth service. We therefore used participatory design to develop a clinical telehealth service for neonatal homecare. The study adopted a participatory design approach to engage users in the development and design of a new telehealth service. Participatory design embraces qualitative research methods. Creative and technical workshops were conducted as part of the study. Tests of the telehealth service were conducted in the neonatal unit. Participants in this study were former and current parents of preterm infants eligible for neonatal homecare, and clinical staff (medical and nursing) from the neonatal unit. Preterm infants accompanied their parents. Based on the results obtained during the workshops and subsequent testing, we developed an application (app), which was integrated into the medical record at the neonatal unit. The app was used to initiate videoconferences and chat messages between the family at home and the neonatal unit, and to share information regarding infant growth and well-being. Results obtained from the workshops and testing demonstrated the importance of involving users when developing new telehealth applications. The workshops helped identify the challenges associated with delivery of the service, and helped instruct the design of a new telehealth service for neonatal homecare based on the needs of parents and clinical staff.

  7. Statistical methods for mass spectrometry-based clinical proteomics

    NARCIS (Netherlands)

    Kakourou, A.

    2018-01-01

    The work presented in this thesis focuses on methods for the construction of diagnostic rules based on clinical mass spectrometry proteomic data. Mass spectrometry has become one of the key technologies for jointly measuring the expression of thousands of proteins in biological samples.

  8. Clinical and microbiological findings of infective endocarditis.

    Science.gov (United States)

    Cancan Gursul, Nur; Vardar, Ilknur; Demirdal, Tuna; Gursul, Erdal; Ural, Serap; Yesil, Murat

    2016-05-31

    Infective endocarditis (IE) is an infection that develops on the endothelial surface of the heart. Endocarditis is a major problem for the clinicians despite of the developments in diagnostic, surgical, and medical treatment methods. In this study, we aimed to evaluate symptoms, laboratory findings, treatment options, and clinical endpoint of the patients who were diagnosed with IE in a tertiary healthcare organization according to the literature data. Between January 2006 and March 2013, 80 IE patients who were diagnosed and treated in accordance with modified Duke criteria were enrolled in the study. Demographic features, symptoms, and laboratory and echocardiographic findings were recorded after reviewing the patient files. The mean age of the patients was 51.3 ± 16.0, and IE was more common in men (n = 56; 70%). Of 41 patients who had positive blood cultures, 20 patients had Staphylococcus spp. (48.7%) and 8 patients had Streptococcus spp. (19.5%). Brucella spp. was isolated from 5 patients (12.2%). While 48.7% (n = 39) of the patients had cardiac complications, 22 patients (27.5%) had embolic complication. Hospital mortality was observed in 20 patients (15%). In our patients, endocarditis was seen at a young age, and staphylococci were the most frequently isolated microorganism from blood culture. There were more patients with Brucella endocarditis compared to the general population. Complications are frequently seen in the course of endocarditis, and they cause problems for the clinicians during follow ups due to the high mortality rate of IE.

  9. Regional Longitudinal Deformation Improves Prediction of Ventricular Tachyarrhythmias in Patients With Heart Failure With Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Knappe, Dorit; Pouleur, Anne-Catherine

    2017-01-01

    BACKGROUND: Left ventricular dysfunction is a known predictor of ventricular arrhythmias. We hypothesized that measures of regional longitudinal deformation by speckle-tracking echocardiography predict ventricular tachyarrhythmias and provide incremental prognostic information over clinical...... in the model, only a decreasing myocardial function in the inferior myocardial wall predicted VT/VF (hazard ratio, 1.05 [1.00-1.11]; P=0.039). Only strain obtained from the inferior myocardial wall provided incremental prognostic information for VT/VF over clinical and echocardiographic parameters (C statistic...... 0.71 versus 0.69; P=0.005). CONCLUSIONS: Assessment of regional longitudinal myocardial deformation in the inferior region provided incremental prognostic information over clinical and echocardiographic risk factors in predicting ventricular tachyarrhythmias. CLINICAL TRIAL REGISTRATION: URL: http...

  10. Computed tomographic, electrocardiographic and clinical investigations in patients with ischemic strokes

    International Nuclear Information System (INIS)

    Manchev, L.; Mitev, M.; Milanova, V.; Zafirova, E.; Manolova, T.; Manchev, I.; Toneva, J.

    2013-01-01

    The Computed Tomography (CT) is a widely available and reliable method for the diagnosis of cerebrovascular disease. It allows in the first hours of the occurrence of vascular events to be established the type of brain stroke and creates conditions for timely fibrinolytic or surgical treatment. In many cases where it cannot be performed echocardiographic examination modern electrocardiography (ECG) makes it possible to demonstrate the presence of cardiac disease. These two methods in combination with neurological status create conditions for determining the treatment strategy for ischemic brain stroke (IBS). We studied 222 patients (92 men and 110 women with a middle age 59.7 years) selected randomized. At a computed tomography study in the early hours of IBS were found pathological findings in 115 patients (51.8%) slightly more often in women. IBS in the carotid system were greatly predominant in comparison with those in the vertebrobasilar system (VBS), which can be explained with the blood flow to the brain stem. When ECG is most commonly met diagnosis: hypertension HSSN 111 stage II - III functional class NYUHA, ischemic cardiomyopathy in 64 patients overall, with almost equal frequency in men 30 (17.5%) and women - 34 (19.8%). In neurological examination significantly predominant clinical symptoms karoditnata vasculature, in 154 patients (69.3%) compared to that of the VBS- 68 (30.7%). Fulfilled study shows the need for better coordination of the activities of specialists in diagnostic imaging and neurologists for their work in specialized hospitals (Stroke Units). (authors)

  11. Avaliação clínico-cardiológica e ecocardiográfica, seqüencial, em crianças portadoras da síndrome de Marfan Serial clinical and echocardiographic evaluation in children with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Victor Manuel Oporto Lopez

    2005-11-01

    Full Text Available OBJETIVO: Descrever a apresentação clínica cardiológica e a evolução temporal, estimar a incidência de ectasia ânulo-aórtica e de prolapso da valva mitral, e avaliar a tolerância e a efetividade dos betabloqueadores em crianças com síndrome de Marfan. MÉTODOS: Foram submetidas a exame clínico e ecocardiográfico seriado, durante um ano, 21 crianças com síndrome de Marfan. No ecocardiograma foram analisados: presença de prolapso mitral, diâmetro da raiz aórtica, refluxos das valvas mitral e aórtica, e o crescimento dos diâmetros aórticos na vigência de betabloqueadores. Em 11 pacientes foi possível obter duas medidas da raiz aórtica no intervalo de um ano. RESULTADOS: Durante o estudo as crianças não apresentaram sintomas. Prolapso mitral foi encontrado em 11 (52% crianças. Ectasia ânulo-aórtica ocorreu em 16 (76% pacientes, sendo de grau discreto em 42,8%, moderado em 9,5%, e importante em 23,8%. Um desses pacientes foi submetido com sucesso à cirurgia de Bentall DeBono. Com o uso de betabloqueador a freqüência cardíaca diminuiu 13,6% (de 85 para 73 bpm; p OBJECTIVE: To describe the clinical cardiac manifestations and temporal evolution of Marfan syndrome in children; to estimate the incidence of annuloaortic ectasia and mitral valve prolapse; and to evaluate tolerability and efficacy of beta-blockers in these patients. METHODS: During one year, 21children with Marfan syndrome underwent serial clinical and echocardiographic examinations. Echocardiograms assessed: the presence of mitral valve prolapse, aortic root diameter, mitral and aortic valves regurgitation, and aortic enlargement during beta-blocker therapy. Eleven patients had two measurements of the aortic root taken one year apart. RESULTS: The children were asymptomatic throughout the study. Mitral prolapse was found in 11 (52% children. Annuloaortic ectasia occurred in 16 (76% patients and found to be mild in 42.8%, moderate in 9.5%, and severe in 23

  12. [Clinical evaluation of TANDEM PSA in Japanese cases and comparison with other methods].

    Science.gov (United States)

    Kuriyama, M; Yamamoto, N; Shinoda, I; Kawada, Y; Akimoto, S; Shimazaki, J

    1995-01-01

    Clinical evaluation of TANDEM PSA which is the most frequently used prostate specific antigen (PSA) assay method in the world and a comparison with other methods were performed in Japanese cases in a cooperative research fashion. The minimum detectable level of the method was found to be 0.50 ng of PSA in one ml of serum and 1.9 ng/ml was regarded as the upper normal value in Japanese males. The distribution of serum PSA showed a significant difference between the benign prostate hypertrophy (BPH) cases and patients with stage C or D prostate cancer. The sero-diagnosis prostate cancer at an early stage with the TANDEM PSA was difficult. The correlation to other methods of PSA detection was very high. Furthermore, the clinical use of the method in following-up the clinical course of prostate cancer patients was very useful. These findings suggested that the PSA detection using TANDEM PSA is applicable even in Japanese cases although the upper cut-off level is decreased.

  13. [Methods of investigation in clinical cardiology. VIII. Socioeconomic evaluation of clinical cardiology practice].

    Science.gov (United States)

    Lázaro de Mercado, P

    1997-06-01

    Health services are systems whose mission is to improve the health status of both individuals and society in general. In recent decades, these systems have faced challenges such as their increasing complexity, limited resources, rapid innovation and diffusion of medical technologies, pressures on demand from society and professionals, and the lack of knowledge of the effects of these factors on costs and society's health. In addition, health care expenditures have grown twice as fast as wealth in industrialized countries during the last 25 years. These problems have prompted cost containment as a key issue in health policy and, at the same time, have promoted the development of socioeconomic evaluation as a scientific activity in the frame of health services research. Socioeconomic evaluation tries to determine if the sacrifice made by society, which devotes part of its limited resources to health care, maximizes the outcomes for population. This article describes basic concepts and methods of economic appraisal in health services which are illustrated with examples of clinical practice in cardiology. Common methods of evaluation are described; the relation between the clinical outcome of a procedure and its associated costs is emphasized in explaining the types of efficiency analysis (cost-efficacy, cost-effectiveness, cost-utility, and cost-benefit); and finally a guide for socioeconomic evaluation is provided.

  14. SU-G-BRC-01: A Data-Driven Pre-Optimization Method for Prediction of Achievability of Clinical Objectives in IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Ranganathan, V; Kumar, P [Philips India Limited, Bangalore, Karnataka (India); Bzdusek, K [Philips, Fitchburg, WI (United States); Das, J Maria [Sanjay Gandhi PG Inst Med Scienes, Lucknow (India)

    2016-06-15

    Purpose: We propose a novel data-driven method to predict the achievability of clinical objectives upfront before invoking the IMRT optimization. Methods: A new metric called “Geometric Complexity (GC)” is used to estimate the achievability of clinical objectives. Here, GC is the measure of the number of “unmodulated” beamlets or rays that intersect the Region-of-interest (ROI) and the target volume. We first compute the geometric complexity ratio (GCratio) between the GC of a ROI (say, parotid) in a reference plan and the GC of the same ROI in a given plan. The GCratio of a ROI indicates the relative geometric complexity of the ROI as compared to the same ROI in the reference plan. Hence GCratio can be used to predict if a defined clinical objective associated with the ROI can be met by the optimizer for a given case. Basically a higher GCratio indicates a lesser likelihood for the optimizer to achieve the clinical objective defined for a given ROI. Similarly, a lower GCratio indicates a higher likelihood for the optimizer to achieve the clinical objective defined for the given ROI. We have evaluated the proposed method on four Head and Neck cases using Pinnacle3 (version 9.10.0) Treatment Planning System (TPS). Results: Out of the total of 28 clinical objectives from four head and neck cases included in the study, 25 were in agreement with the prediction, which implies an agreement of about 85% between predicted and obtained results. The Pearson correlation test shows a positive correlation between predicted and obtained results (Correlation = 0.82, r2 = 0.64, p < 0.005). Conclusion: The study demonstrates the feasibility of the proposed method in head and neck cases for predicting the achievability of clinical objectives with reasonable accuracy.

  15. Características clínicas, electrocardiográficas y ecocardiográficas de la cardiomiopatía chagásica en la población santandereana Clinical, electrocardiographic and echocardiographic characteristics of Chagas’ cardiomyopathy in Santander’s State (Colombia population

    Directory of Open Access Journals (Sweden)

    Franklin Quiroz

    main clinical presentation of CD in Colombia. This article describes the main clinical, electrocardiographic and echocardiographic characteristics of the CCM in Santander, Colombia. Materials and methods: A cross-sectional study of patients of ages between 18 and 80 years, from the Department of Santander, Colombia, with positive serology for T. cruzi, and symptoms of non-terminal heart failure was performed. Physical examination, 12-lead electrocardiogram and 2D echocardiogram were carried out. Results: The study included 62 women and 57 men, mean age 58.5±10.7 years. Hypertension (49.6%, pacemaker implantation (8.4% and dyslipidemia (7.6% were the most frequent antecedents. Left ventricular hypertrophy was seen in 34.3% of the subjects and it was associated to abnormalities in re-polarization. Right bundle branch block was determined in 11.8% of the subjects. Mitral insufficiency was identified by echocardiogram in 61.5% of the participants. None of these variables were associated with a worse functional class state. Discussion: The electrocardiographic characteristics in patients with CCM in Colombia seem to have a different behaviour according to the regions, and for Santander the most frequent findings were left ventricular hypertrophy, abnormalities in repolarization and right bundle branch block. Early interventions on this group of patients are necessary in order to reduce the social and economic impact associated to the CCM.

  16. DNA decontamination methods for internal quality management in clinical PCR laboratories.

    Science.gov (United States)

    Wu, Yingping; Wu, Jianyong; Zhang, Zhihui; Cheng, Chen

    2018-03-01

    The polymerase chain reaction (PCR) technique, one of the most commonly applied methods in diagnostic and molecular biology, has a frustrating downside: the occurrence of false-positive signals due to contamination. In previous research, various DNA decontamination methods have been developed to overcome this limitation. Unfortunately, the use of random or poorly focused sampling methods for monitoring air and/or object surfaces leads to the incomplete elimination during decontamination procedures. We herein attempted to develop a novel DNA decontamination method (environmental surveillance, including surface and air sampling) and quality management program for clinical molecular diagnostic laboratories (or clinical PCR laboratories). Here, we performed a step-by-step evaluation of current DNA decontamination methods and developed an effective procedure for assessing the presence of decontaminating DNA via PCR analysis. Performing targeted environmental surveillance by sampling, which reached optimal performance over 2 weeks, and the decontamination process had been verified as reliable. Additionally, the process was validated to not affect PCR amplification efficiency based on a comparative study. In this study, effective guidelines for DNA decontamination were developed. The method employed ensured that surface DNA contamination could be effectively identified and eliminated. Furthermore, our study highlighted the importance of overall quality assurance and good clinical laboratory practices for preventing contamination, which are key factors for compliance with regulatory or accreditation requirements. Taken together, we provided the evidence that the presented scheme ranged from troubleshooting to the elimination of surface contamination, could serve as critical foundation for developing regular environmental surveillance guidelines for PCR laboratories. © 2017 Wiley Periodicals, Inc.

  17. Clinical and echographic characteristics of patients exposed to fenfluramin or its derivatives: Results of a prospective, single-centre, observational study.

    Science.gov (United States)

    Cambon, David; Leclercq, Florence

    2015-03-01

    Fenfluramine and its derivatives have been associated with significant risk of developing valvular heart disease but its exact prevalence and severity are still debated. To evaluate the clinical and echocardiographic characteristics of patients hospitalized in a cardiology centre and who had past exposure to these drugs. Between July 2011 and February 2012, patients admitted to the hospitalization and intensive care units at the University Centre of Montpellier, France were questioned about past exposure to fenfluramine or its derivatives. In patients who reported exposure, a questionnaire assessing prescribing patterns and medical history was proposed and echocardiography performed. All of the usual echocardiographic variables were analysed. We applied criteria from a French multicentre registry for diagnosis of drug-induced valvulopathy: leaflets and subvalvular apparatus thickening and retraction, leaflets loss of coaptation, no calcification, and no stenosis. Ninety-five patients exposed to these drugs were included. The majority were female (n=62, 65.3%), 53.2% (n=50) had diabetes and 90.5% (n=86) were exposed to benfluorex. Mean treatment duration was 52.3months (95% confidence interval [CI] 39.0-65.6). Valvular regurgitations were observed in 64.0% of patients (n=57) while 19.8% (n=17) had pulmonary hypertension. Highly probable fenfluramine-induced regurgitations were present in 18.6% (n=16) of patients, possibly fenfluramine-induced regurgitations in 38.2% (n=34) of patients, and unlikely fenfluramine-induced regurgitations in 25.8% (n=23) of patients. Highly probable fenfluramine-induced regurgitations were mild to moderate in severity in all except three patients. Considering the frequency of probable or possible fenfluramine-induced regurgitations and in the absence of definite knowledge about the evolution of drug-induced valvular disease, systematic questioning about fenfluramine use may be advisable in hospitalized cardiac patients. Copyright © 2015

  18. Pre-exposure and postexposure prophylaxes and the combination HIV prevention methods (The Combine! Study): protocol for a pragmatic clinical trial at public healthcare clinics in Brazil.

    Science.gov (United States)

    Grangeiro, Alexandre; Couto, Márcia Thereza; Peres, Maria Fernanda; Luiz, Olinda; Zucchi, Eliana Miura; de Castilho, Euclides Ayres; Estevam, Denize Lotufo; Alencar, Rosa; Wolffenbüttel, Karina; Escuder, Maria Mercedes; Calazans, Gabriela; Ferraz, Dulce; Arruda, Érico; Corrêa, Maria da Gloria; Amaral, Fabiana Rezende; Santos, Juliane Cardoso Villela; Alvarez, Vivian Salles; Kietzmann, Tiago

    2015-08-25

    Few results from programmes based on combination prevention methods are available. We propose to analyse the degree of protection provided by postexposure prophylaxis (PEP) for consensual sexual activity at healthcare clinics, its compensatory effects on sexual behaviour; and the effectiveness of combination prevention methods and pre-exposure prophylaxis (PrEP), compared with exclusively using traditional methods. A total of 3200 individuals aged 16 years or older presenting for PEP at 5 sexually transmitted disease (STD)/HIV clinics in 3 regions of Brazil will be allocated to one of two groups: the PEP group-individuals who come to the clinic within 72 h after a sexual exposure and start PEP; and the non-PEP group-individuals who come after 72 h but within 30 days of exposure and do not start PEP. Clinical follow-up will be conducted initially for 6 months and comprise educational interventions based on information and counselling for using prevention methods, including PrEP. In the second study phase, individuals who remain HIV negative will be regrouped according to the reported use of prevention methods and observed for 18 months: only traditional methods; combined methods; and PrEP. Effectiveness will be analysed according to the incidence of HIV, syphilis and hepatitis B and C and protected sexual behaviour. A structured questionnaire will be administered to participants at baseline and every 6 months thereafter. Qualitative methods will be employed to provide a comprehensive understanding of PEP-seeking behaviour, preventive choices and exposure to HIV. This study will be conducted in accordance with the resolution of the School of Medicine Research Ethics Commission of Universidade de São Paulo (protocol no. 251/14). The databases will be available for specific studies, after management committee approval. Findings will be presented to researchers, health managers and civil society members by means of newspapers, electronic media and scientific journals

  19. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2012-02-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  20. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2011-01-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  1. PROTRUSION OF THE DEVICE - A COMPLICATION OF CATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS

    NARCIS (Netherlands)

    OTTENKAMP, J; HESS, J; TALSMA, MD; BUISLIEM, TN

    Objective-To assess the medium term results of percutaneous transvenous closure of patent ductus arteriosus, in particular with regard to protrusion of the device with or without turbulence of the bloodflow. Design-Clinical examination and echocardiographic study (cross sectional Doppler, and colour

  2. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  3. Clinical case review: A method to improve identification of true clinical and radiographic pneumonia in children meeting the World Health Organization definition for pneumonia

    OpenAIRE

    Puumalainen, Taneli; Quiambao, Beatriz; Abucejo-Ladesma, Erma; Lupisan, Socorro; Heiskanen-Kosma, Tarja; Ruutu, Petri; Lucero, Marilla G; Nohynek, Hanna; Simoes, Eric AF; Riley, Ian

    2008-01-01

    Abstract Background The World Health Organization's (WHO) case definition for childhood pneumonia, composed of simple clinical signs of cough, difficult breathing and fast breathing, is widely used in resource poor settings to guide management of acute respiratory infections. The definition is also commonly used as an entry criteria or endpoint in different intervention and disease burden studies. Methods A group of paediatricians conducted a retrospective review of clinical and laboratory da...

  4. [Theory analysis and clinical application of spirit-regulating and pain-relieving acupuncture method].

    Science.gov (United States)

    Chen, Liang; Tang, Lewei; Du, Huaibin; Zheng, Hui; Liang, Fanrong

    2015-04-01

    The theoretical foundation and scientific connotation of spirit-regulating and pain-relieving acupuncture method as well as its clinical application for pain are discussed. During spirit regulation, attention should be paid on regulating heart and brain, while acupoints should be selected mainly from the Heart Meridian, Pericardium Meridian and Governor Vessel. It has significant efficacy for refractory pain in clinical treatment. Spirit-regulating and pain-relieving acupuncture method is development of acupuncture treating spirit, and it is an important method for pain in clinic. Improvement on sensitization of pain center and brain function is considered as one of the mechanisms in spirit-regulating and pain-relieving acupuncture method.

  5. [Adequate application of quantitative and qualitative statistic analytic methods in acupuncture clinical trials].

    Science.gov (United States)

    Tan, Ming T; Liu, Jian-ping; Lao, Lixing

    2012-08-01

    Recently, proper use of the statistical methods in traditional Chinese medicine (TCM) randomized controlled trials (RCTs) has received increased attention. Statistical inference based on hypothesis testing is the foundation of clinical trials and evidence-based medicine. In this article, the authors described the methodological differences between literature published in Chinese and Western journals in the design and analysis of acupuncture RCTs and the application of basic statistical principles. In China, qualitative analysis method has been widely used in acupuncture and TCM clinical trials, while the between-group quantitative analysis methods on clinical symptom scores are commonly used in the West. The evidence for and against these analytical differences were discussed based on the data of RCTs assessing acupuncture for pain relief. The authors concluded that although both methods have their unique advantages, quantitative analysis should be used as the primary analysis while qualitative analysis can be a secondary criterion for analysis. The purpose of this paper is to inspire further discussion of such special issues in clinical research design and thus contribute to the increased scientific rigor of TCM research.

  6. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  7. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    Science.gov (United States)

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  8. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  9. Evaluation of Nucleic Acid Isothermal Amplification Methods for Human Clinical Microbial Infection Detection

    Directory of Open Access Journals (Sweden)

    Brett E. Etchebarne

    2017-12-01

    Full Text Available Battling infection is a major healthcare objective. Untreated infections can rapidly evolve toward the condition of sepsis in which the body begins to fail and resuscitation becomes critical and tenuous. Identification of infection followed by rapid antimicrobial treatment are primary goals of medical care, but precise identification of offending organisms by current methods is slow and broad spectrum empirical therapy is employed to cover most potential pathogens. Current methods for identification of bacterial pathogens in a clinical setting typically require days of time, or a 4- to 8-h growth phase followed by DNA extraction, purification and PCR-based amplification. We demonstrate rapid (70–120 min genetic diagnostics methods utilizing loop-mediated isothermal amplification (LAMP to test for 15 common infection pathogen targets, called the Infection Diagnosis Panel (In-Dx. The method utilizes filtration to rapidly concentrate bacteria in sample matrices with lower bacterial loads and direct LAMP amplification without DNA purification from clinical blood, urine, wound, sputum and stool samples. The In-Dx panel was tested using two methods of detection: (1 real-time thermocycler fluorescent detection of LAMP amplification and (2 visual discrimination of color change in the presence of Eriochrome Black T (EBT dye following amplification. In total, 239 duplicate samples were collected (31 blood, 122 urine, 73 mucocutaneous wound/swab, 11 sputum and two stool from 229 prospectively enrolled hospital patients with suspected clinical infection and analyzed both at the hospital and by In-Dx. Sensitivity (Se of the In-Dx panel targets pathogens from urine samples by In-Dx was 91.1% and specificity (Sp was 97.3%, with a positive predictive value (PPV of 53.7% and a negative predictive value (NPV of 99.7% as compared to clinical microbial detection methods. Sensitivity of detection of the In-Dx panel from mucocutaneous swab samples was 65.5% with a

  10. Q fever in the Greek Island of Crete: epidemiologic, clinical, and therapeutic data from 98 cases.

    Science.gov (United States)

    Tselentis, Y; Gikas, A; Kofteridis, D; Kyriakakis, E; Lydataki, N; Bouros, D; Tsaparas, N

    1995-05-01

    A retrospective study was undertaken in Crete, Greece, to investigate the epidemiologic, clinical, and therapeutic aspects of Q fever. Over a period of 5 years (1989-1993), 1,298 patients were examined and 98 cases were identified. Individuals who were aged 20-29 years and 30-39 years appeared to have an increased risk of infection. Contact with animals was found to be a major risk factor for acquisition of Q fever. The predominant clinical manifestations of the infection were fever (91.7% of patients) and respiratory disease (88.5%), whereas hepatitis was the dominant feature in only a minority (7.1%) of patients. Chest radiographs frequently revealed pulmonary interstitial changes (36.4% of patients) and alveolar changes (34.4%). Abnormal echocardiographic findings were also observed. There was no difference in the duration of fever whether the patient received therapy with tetracycline or erythromycin, a finding that may be explained by the delay in initiating tetracycline therapy.

  11. MR imaging of aortic coarctation

    International Nuclear Information System (INIS)

    Beslic, S.

    2004-01-01

    Purpose. The purpose of this paper is to analyse the contribution of MRI as diagnostic procedure in the preoperative diagnosis of aortic coarctation (CoA), in patients with clinical and echocardiographic suspicion for this disease. Patients and methods. During the period of three years, eight patients were examined, 5 (62.5%) male and 3 (37.5%) female patients with clinical echocardiographic suspicion of CoA. The ratio between male and female patients was 1.7 : 1. The youngest patient was 3 and the oldest 46 years (median age was 15 years). Without administration of contrast media and using body coil the examinations were performed with MR machine Magnetom 1.0 Tesla ( S iemens ) , with the slice thickness of 6 mm, Fast spin-echo (FSE) T1W sequences, Cine gradient echo (GRE) sequence with slab 7 mm and time of flight (TOF) sequence with MIP reconstructions were applied. During the examinations the patients underwent also ECG gating. Examinations were done in axial, coronal and oblique sagittal projections with measuring of the dimensions of cardiovascular structures. Results. CoA was found in 8 (100%) patients. In 7 (87.5%) cases, coarctation developed at isthmus and in one case, coarctation was detected at the horizontal part of aortic arch, between the truncus arteriosus of the left carotid communis artery. Aortal insufficiency was found in 7 (87.5%) patients; in four of them (50%), bicuspidia was confirmed (bicuspid aortic valve), 7 (87.5%) patients had slightly expressed hypertrophy of the left ventricle. Two (25%) patients had dilatation of the ascendant aorta, six (75%) wider outgoing vessels of the aortic arch, four (50%) had well developed arterial collaterals and 2 (25%) patients rib notching. In 2 (25%) patients as side finding thymus persistent was found. Average diameter of coarctation was 10 mm. In one patient, CoA was accompanied with stenosis of pulmonary artery, in one with ventricular septal defect, and one with tricuspid insufficiency. The results

  12. Cognitive Machine-Learning Algorithm for Cardiac Imaging: A Pilot Study for Differentiating Constrictive Pericarditis From Restrictive Cardiomyopathy.

    Science.gov (United States)

    Sengupta, Partho P; Huang, Yen-Min; Bansal, Manish; Ashrafi, Ali; Fisher, Matt; Shameer, Khader; Gall, Walt; Dudley, Joel T

    2016-06-01

    Associating a patient's profile with the memories of prototypical patients built through previous repeat clinical experience is a key process in clinical judgment. We hypothesized that a similar process using a cognitive computing tool would be well suited for learning and recalling multidimensional attributes of speckle tracking echocardiography data sets derived from patients with known constrictive pericarditis and restrictive cardiomyopathy. Clinical and echocardiographic data of 50 patients with constrictive pericarditis and 44 with restrictive cardiomyopathy were used for developing an associative memory classifier-based machine-learning algorithm. The speckle tracking echocardiography data were normalized in reference to 47 controls with no structural heart disease, and the diagnostic area under the receiver operating characteristic curve of the associative memory classifier was evaluated for differentiating constrictive pericarditis from restrictive cardiomyopathy. Using only speckle tracking echocardiography variables, associative memory classifier achieved a diagnostic area under the curve of 89.2%, which improved to 96.2% with addition of 4 echocardiographic variables. In comparison, the area under the curve of early diastolic mitral annular velocity and left ventricular longitudinal strain were 82.1% and 63.7%, respectively. Furthermore, the associative memory classifier demonstrated greater accuracy and shorter learning curves than other machine-learning approaches, with accuracy asymptotically approaching 90% after a training fraction of 0.3 and remaining flat at higher training fractions. This study demonstrates feasibility of a cognitive machine-learning approach for learning and recalling patterns observed during echocardiographic evaluations. Incorporation of machine-learning algorithms in cardiac imaging may aid standardized assessments and support the quality of interpretations, particularly for novice readers with limited experience. © 2016

  13. Utility of qualitative methods in a clinical setting: perinatal care in the Western Province.

    Science.gov (United States)

    Jayasuriya, V

    2012-03-01

    A peculiar paradox that has been observed in previous studies of antenatal care is where patients are satisfied with the services despite obvious lack of basic facilities. Qualitative methods were used to describe the experience of perinatal care in the Western province with the objective of demonstrating application of this method in a clinical setting. This paper used a 'naturalistic' approach of qualitative methods. In-depth interviews conducted with 20 postnatal mothers delivering in tertiary care institutions in the Western province was tape recorded, transcribed and content analysed. To ensure objectivity and validity of results, the principle investigator received only the anonymised data to prevent any prejudices or pre-conceptions affecting the results. The main themes emerging from the text demonstrated 'naïve trust' in the carer and a state of 'hero worship' where patients were distanced and therefore unable and unwilling to query the decisions made by the carers. This is similar to a state of patient-carer relationship described in a published model known as guarded alliance, where the relationship develops though four phases based on the level of trust and confidence in the relationship. This state explains not only why patients fail to recognise and report any deficiencies in the services but also the need for them to justify the behaviour of caregivers even when it amounts to incompetence and negligence. Qualitative methods allow the researcher to capture experiences in its 'natural' form rather than based on pre-determined protocols or plans, which may be limited to our own understanding and expectations and therefore unable to explain many idiosyncrasies of the programmes. This paper argues favourably for the use of qualitative methods in other clinical settings.

  14. Enrichment methods to detect bone marrow micrometastases in breast carcinoma patients: clinical relevance

    International Nuclear Information System (INIS)

    Choesmel, Valérie; Pierga, Jean-Yves; Nos, Claude; Vincent-Salomon, Anne; Sigal-Zafrani, Brigitte; Thiery, Jean-Paul; Blin, Nathalie

    2004-01-01

    Improving technologies for the detection and purification of bone marrow (BM) micrometastatic cells in breast cancer patients should lead to earlier prognosis of the risk of relapse and should make it possible to design more appropriate therapies. The technique used has to overcome the challenges resulting from the small number of target cells (one per million hematopoietic cells) and the heterogeneous expression of micrometastatic cell markers. In the present study, we have assessed the clinical relevance of current methods aimed at detecting rare disseminated carcinoma cells. BM aspirates from 32 carcinoma patients were screened for the presence of micrometastatic cells positive for epithelial cell adhesion molecule and positive for cytokeratins, using optimized immunodetection methods. A comparison with data obtained for 46 control BM aspirates and a correlation with the clinical status of patients were performed. We developed a sensitive and efficient immunomagnetic protocol for the enrichment of BM micrometastases. This method was used to divide 32 breast carcinoma patients into three categories according to their epithelial cell adhesion molecule status. These categories were highly correlated with the recently revised American Joint Committee on Cancer staging system for breast cancer, demonstrating the clinical relevance of this simple and reliable immunomagnetic technique. We also evaluated immunocytochemical detection of cytokeratin-positive cells and cytomorphological parameters. Immunocytochemistry-based methods for the detection of BM micrometastases did not provide any information about the clinical status of patients, but helped to refine the immunomagnetic data by confirming the presence of micrometastases in some cases. We also tested a new density gradient centrifugation system, able to enrich the tumor fraction of BM specimens by twofold to threefold as compared with standard Ficoll methods. These improved methods for the detection of

  15. Prognostic value of clinical and Doppler echocardiographic findings in children and adolescents with significant rheumatic valvular disease

    International Nuclear Information System (INIS)

    Araújo, Fátima Derlene da Rocha; Goulart, Eugênio Marcos Andrade; Meira, Zilda Maria Alves

    2012-01-01

    The diagnosis of acute rheumatic fever (RF) is based on clinical findings. However, during the chronic phase of the disease, the clinical approach is not sufficient for the follow-up of the patients and the Doppler echocardiography is a tool for the diagnosis of cardiac involvement. Prognostic variables that influence long-term outcomes are not well known. 462 patients with RF according to Jones criteria were studied, and followed-up from the initial attack to 13.6 ± 4.6 years. All patients underwent clinical assessment and Doppler echocardiography for the detection of heart valve involvement in the acute and chronic phases. Multivariate logistic regression analysis was used to identify the factors influencing long-term heart valve disease. Carditis occurred in 55.8% and subclinical valvulitis in 35.3% patients. In the chronic phase, 33% of the patients had significant valvular heart disease. No normal Doppler echocardiography exam was observed on patients who had severe valvulitis, although heart auscultation had become normal in 13% of these. In the multivariate analysis, only the severity of carditis and the mitral and/or aortic valvulitis were associated with significant valvular heart disease. Chorea or arthritis were protective factors for significant valvular heart disease, odds ratio 0.41 (95% C.I. 0.22 – 0.77) and 0.43 (95% C.I. 0.23 – 0.82), respectively. Our study suggests that the use of Doppler echocardiography during RF helps to identify prognostic factors regarding the development of significant valvular heart disease. Initial severe carditis is an important factor in the long-term prognosis of chronic RHD, whereas arthritis and chore during the initial episode of RF appears to be protective. Strict secondary prophylaxis should be mandatory in high risk patients

  16. Assessing data quality and the variability of source data verification auditing methods in clinical research settings.

    Science.gov (United States)

    Houston, Lauren; Probst, Yasmine; Martin, Allison

    2018-05-18

    Data audits within clinical settings are extensively used as a major strategy to identify errors, monitor study operations and ensure high-quality data. However, clinical trial guidelines are non-specific in regards to recommended frequency, timing and nature of data audits. The absence of a well-defined data quality definition and method to measure error undermines the reliability of data quality assessment. This review aimed to assess the variability of source data verification (SDV) auditing methods to monitor data quality in a clinical research setting. The scientific databases MEDLINE, Scopus and Science Direct were searched for English language publications, with no date limits applied. Studies were considered if they included data from a clinical trial or clinical research setting and measured and/or reported data quality using a SDV auditing method. In total 15 publications were included. The nature and extent of SDV audit methods in the articles varied widely, depending upon the complexity of the source document, type of study, variables measured (primary or secondary), data audit proportion (3-100%) and collection frequency (6-24 months). Methods for coding, classifying and calculating error were also inconsistent. Transcription errors and inexperienced personnel were the main source of reported error. Repeated SDV audits using the same dataset demonstrated ∼40% improvement in data accuracy and completeness over time. No description was given in regards to what determines poor data quality in clinical trials. A wide range of SDV auditing methods are reported in the published literature though no uniform SDV auditing method could be determined for "best practice" in clinical trials. Published audit methodology articles are warranted for the development of a standardised SDV auditing method to monitor data quality in clinical research settings. Copyright © 2018. Published by Elsevier Inc.

  17. Echocardiography as an approach for canine cardiac disease diagnosis

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-11-01

    Full Text Available Aim: The aim of the study was to establish the methods for diagnosis various canine cardiac ailments using echocardiography. Materials and Methods: M-mode, two-dimensional echocardiography and Doppler studies were performed on 10 cases. Dogs showing signs of cardiac ailment either clinically, radiographic or via electrocardiographic examination were selected for study. Right parasternal short axis view was used for echocardiographic measurements. Right parasternal long axis and left parasternal apical views were used for Doppler studies. Doppler studies were performed at the level of aortic valve and atrioventricular valves for semi quantitative diagnosis of regurgitation. Results: Dogs were found affected with dilated cardiomyopathy (DCM (n=5, pericardial effusion (PE (n=1, combined PE and DCM (n=2 and remaining two showed abnormality on radiographic or electrographically evaluation but were found out to be normal echocardiographically (n=2. Conclusion: Echocardiography is an effective tool for diagnosis of various heart ailments.

  18. Changes in nursing students' expectations of nursing clinical faculties' competences: A longitudinal, mixed methods study.

    Science.gov (United States)

    Lovrić, Robert; Prlić, Nada; Milutinović, Dragana; Marjanac, Igor; Žvanut, Boštjan

    2017-12-01

    Changes in nursing students' expectations of their clinical nursing faculty competences over the course of time are an insufficiently researched phenomenon. To explore what competences BSc nursing students expect from their clinical faculties during their clinical training, and whether their expectations changed during their three-year studies. Furthermore, to survey factors which influenced their expectations and whether the fulfilment levels of their expectations influenced their feelings, learning, and behaviour. A two-phase, mixed-methods design was used. The Higher Nursing Education Institution in Osijek, Croatia, European Union. A cohort of 34 BSc nursing students, who were followed over the course of their three-year studies. In Phase I, in each year, prior to their clinical training, participants responded to the same modified Nursing Clinical Teacher Effectiveness Inventory questionnaire about their expectations of clinical faculties' competences (52 items representing six categories of competences). In Phase II, seven days after their graduation, participants wrote reflections on the aforementioned expectations during their studies. The results show that Clinical faculties' evaluation of student was the category in which participants had the highest expectations in all three years. Results of Wilcoxon signed rank test indicate a significant increase of participants' expectations in all categories of clinical nursing faculties' competences during their study. Participants' reflections confirm these results and indicate that actual competences of clinical faculties and behaviour have the most significant effects on the change in these expectations. Participants reported that expectations, if fulfilled, facilitate their learning and motivation for better performance. BSc nursing students' expectations of clinical nursing faculty competences represent an important concept, as they obviously determine the quality of faculty practice. Hence, they should be

  19. Primary Mitral Valve Regurgitation Outcome in Patients With Severe Aortic Stenosis 1 Year After Transcatheter Aortic Valve Implantation: Echocardiographic Evaluation

    Directory of Open Access Journals (Sweden)

    Thiago Marinho Florentino

    Full Text Available Abstract Background: Mitral valve regurgitation (MR, present in up to 74% of the patients with severe aortic stenosis (AS, can be a negative prognostic factor when moderate or severe. The outcome of MR after percutaneous transcatheter aortic valve implantation (TAVI and predictors associated with that outcome have not been well established in the literature. Objective: To assess the outcome of primary MR in patients submitted to TAVI and to identify associated factors. Methods: Observational study of patients with symptomatic severe AS submitted to TAVI from January 2009 to April 2015 at two specialized centers. Echocardiographic outcome was assessed with data collected before and 1 year after TAVI. Results: Of the 91 patients with MR submitted to TAVI and followed up for at least 12 months, 67 (73.6% had minimum/mild MR before the procedure and 24 (26.4% had moderate/severe MR. Of those with minimum/mild MR, 62 (92.5% had no change in the MR grade (p < 0.001, while 5 (7.5% showed worsening. Of those with moderate/severe MR, 8 (33.3% maintained the same grade and 16 (66.7% improved it (p = 0.076. Patients with moderate/severe MR who improved MR grade had lower EuroSCORE II (p = 0.023 and STS morbidity (p = 0.027 scores, as compared to those who maintained the MR grade. Conclusion: MR grades change after TAVI. This study suggests a trend towards improvement in moderate/severe MR after TAVI, which was associated with lower preoperative risk scores.

  20. Anatomic, histopathologic, and echocardiographic features in a dog with an atypical pulmonary valve stenosis with a fibrous band of tissue and a patent ductus arteriosus.

    Science.gov (United States)

    Yoon, Hakyoung; Kim, Jaehwan; Nahm, Sang-Soep; Eom, Kidong

    2017-07-11

    Congenital pulmonary valve stenosis and patent ductus arteriosus are common congenital heart defects in dogs. However, concurrence of atypical pulmonary valve stenosis and patent ductus arteriosus is uncommon. This report describes the anatomic, histopathologic, and echocardiographic features in a dog with concomitant pulmonary valve stenosis and patent ductus arteriosus with atypical pulmonary valve dysplasia that included a fibrous band of tissue. A 1.5-year-old intact female Chihuahua dog weighing 3.3 kg presented with a continuous grade VI cardiac murmur, poor exercise tolerance, and an intermittent cough. Echocardiography indicated pulmonary valve stenosis, a thickened dysplastic valve without annular hypoplasia, and a type IIA patent ductus arteriosus. The pulmonary valve was thick line-shaped in systole and dome-shaped towards the right ventricular outflow tract in diastole. The dog suffered a fatal cardiac arrest during an attempted balloon pulmonary valvuloplasty. Necropsy revealed pulmonary valve dysplasia, commissural fusion, and incomplete opening and closing of the pulmonary valve because of a fibrous band of tissue causing adhesion between the right ventricular outflow tract and the dysplastic intermediate cusp of the valve. A fibrous band of tissue between the right ventricular outflow track and the pulmonary valve should be considered as a cause of pulmonary valve stenosis. Pulmonary valve stenosis and patent ductus arteriosus can have conflicting effects on diastolic and systolic dysfunction, respectively. Therefore, beta-blockers should always be used carefully, particularly in patients with a heart defect where there is concern about left ventricular systolic function.

  1. The effect of raloxifene on left ventricular hypertrophy in postmenopausal women: A prospective, randomized, and controlled study

    Science.gov (United States)

    Bal, Uğur Abbas; Atar, İlyas; Öktem, Mesut; B. Zeyneloğlu, Hulusi; Yıldırır, Aylin; Kuşcu, Esra; Müderrisoğlu, Haldun

    2015-01-01

    Objective: In healthy women, there is a progressive age-related increase in myocardial mass that is not seen in their male counterparts and occurs primarily in postmenopausal women. Raloxifene is a selective estrogen receptor modulator that has estrogenic actions on bone and the cardiovascular system. The aim of this study was to investigate the effect of raloxifene on myocardial hypertrophy in postmenopausal patients. Methods: A total of 22 postmenopausal osteoporotic women were included in this open-label, randomized, prospective, controlled study. Patients were randomized into two groups: 11 of the patients (group 1) were treated with raloxifene 60 mg/day, and the other 11 patients (group 2) were defined as the control group. Quantitative 2-dimensional and M-mode echocardiographic examination was performed in all patients at the beginning and repeated at the end of the 6-month follow-up period. Left ventricle mass (LVM) and left ventricle mass index (LVMI) were calculated for all patients. Results: The mean age of the patients was 57.2±3.9 years, and baseline clinical characteristics and echocardiographic parameters were similar between the two groups. After 6 months of raloxifene treatment, there was no difference in echocardiographic parameters of LVM and LVMI compared with the control group (201.2±25.9 gr vs. 169.7±46.2 gr, p=0.14 and 120.4±25.9 gr/m2 vs. 105.5±26.3 gr/m2, p=0.195, respectively). There was also no significant difference in LVM and LVMI in the within-group analysis of both groups. Conclusion: Raloxifene therapy does not affect myocardial hypertrophy in postmenopausal women after 6 months of treatment. PMID:25430415

  2. Spatiotemporal Segmentation and Modeling of the Mitral Valve in Real-Time 3D Echocardiographic Images.

    Science.gov (United States)

    Pouch, Alison M; Aly, Ahmed H; Lai, Eric K; Yushkevich, Natalie; Stoffers, Rutger H; Gorman, Joseph H; Cheung, Albert T; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2017-09-01

    Transesophageal echocardiography is the primary imaging modality for preoperative assessment of mitral valves with ischemic mitral regurgitation (IMR). While there are well known echocardiographic insights into the 3D morphology of mitral valves with IMR, such as annular dilation and leaflet tethering, less is understood about how quantification of valve dynamics can inform surgical treatment of IMR or predict short-term recurrence of the disease. As a step towards filling this knowledge gap, we present a novel framework for 4D segmentation and geometric modeling of the mitral valve in real-time 3D echocardiography (rt-3DE). The framework integrates multi-atlas label fusion and template-based medial modeling to generate quantitatively descriptive models of valve dynamics. The novelty of this work is that temporal consistency in the rt-3DE segmentations is enforced during both the segmentation and modeling stages with the use of groupwise label fusion and Kalman filtering. The algorithm is evaluated on rt-3DE data series from 10 patients: five with normal mitral valve morphology and five with severe IMR. In these 10 data series that total 207 individual 3DE images, each 3DE segmentation is validated against manual tracing and temporal consistency between segmentations is demonstrated. The ultimate goal is to generate accurate and consistent representations of valve dynamics that can both visually and quantitatively provide insight into normal and pathological valve function.

  3. Diagnostic Utility of High Sensitivity Troponins for Echocardiographic Markers of Structural Heart Disease.

    Science.gov (United States)

    Wang, Tom Kai Ming; Dugo, Clementina; Gillian, Yvonne; Yvonne, Wynne; Heather, Semple; Kevin, Smith; Peter, Cleave; Jonathan, Christiansen; Andrew, To; Nezar, Amir; Scott, Tony; Ross, Boswell; Patrick, Gladding

    2018-02-15

    The conventional use of high-sensitivity troponins (hs-troponins) is for diagnosing myocardial infarction however they also have a role in chronic disease management. This pilot study assessed the relationship of hs-troponins with echocardiographic markers of left ventricular hypertrophy (LVH) and structural heart disease (SHD). Patients undergoing computer gomography (CT) coronary angiogram for low-intermediate risk chest pain and healthy volunteers were recruited. Hs-troponins Singulex I, Abbott I and Roche T and N-terminal pro-brain natriuretic peptide (NT-proBNP) were evaluated in relation to SHD parameters including left ventricular hypertrophy (LVH Echo ) and left atrial enlargement (LAE Echo ) on echocardiography. 78 subjects who underwent echocardiography were included in this study. C-statistics (95% confidence interval) of the four biomarkers for predicting LVH Echo were 0.84 (0.72-0.92), 0.84 (0.73-0.92), 0.75 (0.63-0.85) and 0.62 (0.49-0.74); for LAE Echo 0.74 (0.6-0.85), 0.78 (0.66-0.88), 0.55 (0.42-0.67) and 0.68 (0.62-0.85); and composite SHD 0.79 (0.66-0.88), 0.87 (0.75-0.94), 0.62 (0.49-0.73) and 0.74 (0.62-0.84) respectively. Optimal cut points for SHD were >1.2 ng/L, >1.6 ng/L, >8 ng/L and >18 pmol/L respectively. These results advocate the potential role of hs-troponins as screening tools for structural heart disease with theranostic implications.

  4. Content analysis of medical students’ seminars: a unique method of analyzing clinical thinking

    Science.gov (United States)

    2013-01-01

    Background The study of communication skills of Asian medical students during structured Problem-based Learning (PBL) seminars represented a unique opportunity to assess their critical thinking development. This study reports the first application of the health education technology, content analysis (CA), to a Japanese web-based seminar (webinar). Methods The authors assigned twelve randomly selected medical students from two universities and two clinical instructors to two virtual classrooms for four PBL structured tutoring sessions that were audio-video captured for CA. Both of the instructors were US-trained physicians. This analysis consisted of coding the students’ verbal comments into seven types, ranging from trivial to advanced knowledge integration comments that served as a proxy for clinical thinking. Results The most basic level of verbal simple responses accounted for a majority (85%) of the total students’ verbal comments. Only 15% of the students’ comments represented more advanced types of critical thinking. The male students responded more than the female students; male students attending University 2 responded more than male students from University 1. The total mean students’ verbal response time for the four sessions with the male instructor was 6.9%; total mean students’ verbal response time for the four sessions with the female instructor was 19% (p student clinical training webinar in two Japanese medical schools. These results are preliminary, mostly limited by a small sample size (n = 12) and limited time frame (four sessions). CA technology has the potential to improve clinical thinking for medical students. This report may stimulate improvements for implementation. PMID:24289320

  5. Utility of Tissue Doppler Imaging in the Echocardiographic Evaluation of Left and Right Ventricular Function in Dogs with Myxomatous Mitral Valve Disease with or without Pulmonary Hypertension.

    Science.gov (United States)

    Baron Toaldo, M; Poser, H; Menciotti, G; Battaia, S; Contiero, B; Cipone, M; Diana, A; Mazzotta, E; Guglielmini, C

    2016-05-01

    In human medicine, right ventricular (RV) functional parameters represent a tool for risk stratification in patients with congestive heart failure caused by left heart disease. Little is known about RV alterations in dogs with left-sided cardiac disorders. To assess RV and left ventricular (LV) function in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH). One-hundred and fourteen dogs: 28 healthy controls and 86 dogs with MMVD at different stages. Prospective observational study. Animals were classified as healthy or having MMVD at different stages of severity and according to presence or absence of PH. Twenty-eight morphological, echo-Doppler, and tissue Doppler imaging (TDI) variables were measured and comparison among groups and correlations between LV and RV parameters were studied. No differences were found among groups regarding RV echo-Doppler and TDI variables. Sixteen significant correlations were found between RV TDI and left heart echocardiographic variables. Dogs with PH had significantly higher transmitral E wave peak velocity and higher E/e' ratio of septal (sMV) and lateral (pMV) mitral annulus. These 2 variables were found to predict presence of PH with a sensitivity of 84 and 72%, and a specificity of 71 and 80% at cut-off values of 10 and 9.33 for sMV E/e' and pMV E/e', respectively. No association between variables of RV function and different MMVD stage and severity of PH could be detected. Some relationships were found between echocardiographic variables of right and left ventricular function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  6. Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods.

    Science.gov (United States)

    Imbriaco, Massimo; Nappi, Carmela; Puglia, Marta; De Giorgi, Marco; Dell'Aversana, Serena; Cuocolo, Renato; Ponsiglione, Andrea; De Giorgi, Igino; Polito, Maria Vincenza; Klain, Michele; Piscione, Federico; Pace, Leonardo; Cuocolo, Alberto

    2017-10-26

    To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

  7. Feasibility study of structured diagnosis methods for functional dyspepsia in Korean medicine clinics

    Directory of Open Access Journals (Sweden)

    Jeong Hwan Park

    2017-12-01

    Full Text Available Background: Functional dyspepsia (FD is the seventh most common disease encountered in Korean medicine (KM clinics. Despite the large number of FD patients visiting KM clinics, the accumulated medical records have no utility in evidence development, due to being unstructured. This study aimed to construct a standard operating procedure (SOP with appropriate structured diagnostic methods for FD, and assess the feasibility for use in KM clinics. Methods: Two rounds of professional surveys were conducted by 10 Korean internal medicine professors to select the representative diagnostic methods. A feasibility study was conducted to evaluate compliance and time required for using the structured diagnostic methods by three specialists in two hospitals. Results: As per the results of the professional survey, five questionnaires and one basic diagnostic method were selected. An SOP was constructed based on the survey results, and a feasibility study showed that the SOP compliance score (out of 5 was 3.45 among the subjects, and 3.25 among the practitioners. The SOP was acceptable and was not deemed difficult to execute. The total execution time was 136.5 minutes, out of which the gastric emptying test time was 129 minutes. Conclusion: This feasibility study of the SOP with structured diagnostic methods for FD confirmed it was adequate for use in KM clinics. It is expected that these study findings will be helpful to clinicians who wish to conduct observational studies as well as to generate quantitative medical records to facilitate Big Data research. Keywords: Big Data, Dyspepsia, Korean medicine, Feasibility studies, Observational study

  8. When are night shifts effective for nursing student clinical learning? Findings from a mixed-method study design.

    Science.gov (United States)

    Palese, Alvisa; Basso, Felix; Del Negro, Elena; Achil, Illarj; Ferraresi, Annamaria; Morandini, Marzia; Moreale, Renzo; Mansutti, Irene

    2017-05-01

    Some nursing programmes offer night shifts for students while others do not, mainly due to the lack of evidence regarding their effectiveness on clinical learning. The principal aims of the study were to describe nursing students' perceptions and to explore conditions influencing effectiveness on learning processes during night shifts. An explanatory mixed-method study design composed of a cross-sectional study (primary method, first phase) followed by a descriptive phenomenological study design (secondary method, second phase) in 2015. Two bachelor of nursing degree programmes located in Northern Italy, three years in length and requiring night shifts for students starting in the second semester of the 1st year, were involved. First phase: all nursing students ending their last clinical placement of the academic year attended were eligible; 352 out the 370 participated. Second phase: a purposeful sample of nine students among those included in the first phase and who attended the highest amount of night shifts were interviewed. First phase: a questionnaire composed of closed and open-ended questions was adopted; data was analyzed through descriptive statistical methods. Second phase: an open-ended face-to-face audio-recorded interview was adopted and data was analyzed through content analysis. Findings from the quantitative phase, showed that students who attended night shifts reported satisfaction (44.7%) less frequently than those who attended only day shifts (55.9%). They also reported boredom (23.5%) significantly more often compared to day shift students (p=0001). Understanding of the nursing role and learning competence was significantly inferior among night shift students as compared to day shift students, while the perception of wasting time was significantly higher among night shift students compared to their counterparts. Night shift students performed nursing rounds (288; 98.2%), non-nursing tasks (247; 84.3%) and/or less often managed clinical problems

  9. Comparative study among calibration methods of clinical applicators of beta radiation

    International Nuclear Information System (INIS)

    Antonio, Patricia de Lara

    2009-01-01

    90 Sr+ 90 Y clinical applicators are instruments used in brachytherapy procedures and they have to be periodically calibrated, according to international standards and recommendations. In this work, four calibration methods of dermatological and ophthalmic applicators were studied, comparing the results with those given by the calibration certificates of the manufacturers. The methods included the use of the standard applicator of the Calibration Laboratory (LCI), calibrated by the National Institute of Standards and Technology; an Amersham applicator (LCI) as reference; a mini-extrapolation chamber developed at LCI as an absolute standard; and thermoluminescent dosimetry. The mini-extrapolation chamber and a PTW commercial extrapolation chamber were studied in relation to their performance through quality control tests of their response, as leakage current, repeatability and reproducibility. The distribution of the depth dose in water, that presents high importance in dosimetry of clinical applicators, was determined using the mini extrapolation chamber and the thermoluminescent dosimeters. The results obtained were considered satisfactory for the both cases, and comparable to the data of the IAEA (2002) standard. Furthermore, a dosimetry postal kit was developed for the calibration of clinical applicators using the thermoluminescent technique, to be sent to clinics and hospitals, without the need of the transport of the sources to IPEN for calibration. (author)

  10. Is mechanical dyssynchrony still a major determinant for responses after cardiac resynchronization therapy?

    International Nuclear Information System (INIS)

    Zhang Qing; Yu Cheuk Man

    2011-01-01

    The assessment of mechanical dyssynchrony by advanced echocardiographic technologies and its importance in selecting more appropriate candidates for cardiac resynchronization therapy (CRT) have been disputed, after the announcement of the Predictors of Response to CRT (PROSPECT) trial, as the first evidence derived from a multicenter study. However, attempts in this field have never been stopped, as it appears that the fundamental mechanism of CRT is the correction of dyssynchrony where the detection of baseline dyssynchrony is of particular significance. The QRS width provides simple but very limited information. On the other hand, non-invasive imaging tools such as echocardiography have the capacity for more detailed analysis of mechanical dyssynchrony. We reviewed a number of clinical studies published in the post-PROSPECT era, designed to figure out a predictive algorithm where dyssynchrony measure is included, for identifying the most suitable patients before device implantation. From the analysis, mechanical dyssynchrony remains to be a major determinant for clinical outcomes after CRT, although discrepancies have arisen with respect to the single-center nature, echocardiographic methodologies, and relative merit when compared with other predicting factors. (author)

  11. Trastuzumab Induces an Immediate, Transient Volume Increase in Humans: A Randomised Placebo-Controlled Trial

    Directory of Open Access Journals (Sweden)

    Joannes A.A. Reijers

    2015-08-01

    Interpretation: Single dose administration of trastuzumab in humans is associated with an immediate, transient extracellular volume increase, either as a primary or secondary (compensatory response, which can be detected easily using routine clinical assessments. Echocardiographic changes, both short and long term, could not be found after single dose administration to drug-naive patients.

  12. Evaluating current automatic de-identification methods with Veteran’s health administration clinical documents

    Directory of Open Access Journals (Sweden)

    Ferrández Oscar

    2012-07-01

    Full Text Available Abstract Background The increased use and adoption of Electronic Health Records (EHR causes a tremendous growth in digital information useful for clinicians, researchers and many other operational purposes. However, this information is rich in Protected Health Information (PHI, which severely restricts its access and possible uses. A number of investigators have developed methods for automatically de-identifying EHR documents by removing PHI, as specified in the Health Insurance Portability and Accountability Act “Safe Harbor” method. This study focuses on the evaluation of existing automated text de-identification methods and tools, as applied to Veterans Health Administration (VHA clinical documents, to assess which methods perform better with each category of PHI found in our clinical notes; and when new methods are needed to improve performance. Methods We installed and evaluated five text de-identification systems “out-of-the-box” using a corpus of VHA clinical documents. The systems based on machine learning methods were trained with the 2006 i2b2 de-identification corpora and evaluated with our VHA corpus, and also evaluated with a ten-fold cross-validation experiment using our VHA corpus. We counted exact, partial, and fully contained matches with reference annotations, considering each PHI type separately, or only one unique ‘PHI’ category. Performance of the systems was assessed using recall (equivalent to sensitivity and precision (equivalent to positive predictive value metrics, as well as the F2-measure. Results Overall, systems based on rules and pattern matching achieved better recall, and precision was always better with systems based on machine learning approaches. The highest “out-of-the-box” F2-measure was 67% for partial matches; the best precision and recall were 95% and 78%, respectively. Finally, the ten-fold cross validation experiment allowed for an increase of the F2-measure to 79% with partial matches

  13. Bedside Teaching: Is it Effective Methods in Clinical Nursing Students Learning?

    Directory of Open Access Journals (Sweden)

    Fatikhu Yatuni Asmara

    2017-01-01

    Full Text Available Introduction: Clinical learning is the centre of medical students education. Students not only learn about practical skills but also communication with patient and other health care givers which both competencies are useful for students when they come into working world (Spencer, 2003. There are variations of methods applied in clinical learning process; one of them is bedside teaching. The aim of this study was to observe the bedside teaching process which is held in group of students, teacher, and patient. Another aim was to know responses of students, teacher, and patients to the bedside teaching process. Method: The method which was applied in this study is observation in which bedside teaching process was observed related to the roles and function of each component of bedside teaching: students, teacher, and patient in each phase: preparation, process, and evaluation. Then it was continued by interview to know the responses of students, teacher, and patient related to bedside teaching process. Result: The result showed that both students and teacher felt that bedside teaching is an effective method since it helped students to achieve their competences in clinical setting and develop their communication skill. Furthermore teacher stated that bedside teaching facilitated her to be a good role model for students. As well as students and teacher, patient got advantage from the bedside teaching process that she got information related to her case; however the time to discuss was limited. During the observation, each component of bedside teaching did their roles and function, such as: during the preparation teacher asked inform consent from patient, and patient gave inform consent as well while students prepared the material. Discussions: Suggestion for next research is conducting a deeper study about perception of students, teacher, and patient about bedside teaching process and the strategies to develop it to be better method. Keywords: bedside

  14. Counseling Psychology Doctoral Trainees' Satisfaction with Clinical Methods Training

    Science.gov (United States)

    Menke, Kristen Ann

    2015-01-01

    Counseling psychology doctoral trainees' satisfaction with their clinical methods training is an important predictor of their self-efficacy as counselors, persistence in graduate programs, and probability of practicing psychotherapy in their careers (Fernando & Hulse-Killacky, 2005; Hadjipavlou & Ogrodniczuk, 2007; Morton & Worthley,…

  15. Measurement properties of clinical assessment methods for classifying generalized joint hypermobility

    DEFF Research Database (Denmark)

    Juul-Kristensen, Birgit; Schmedling, Karoline; Rombaut, Lies

    2017-01-01

    methods. For BS-self, the validity showed unknown evidence compared with test assessment methods. In conclusion, following recommended uniformity of testing procedures, the recommendation for clinical use in adults is BS with cut-point of 5 of 9 including historical information, while in children it is BS...... with cut-point of at least 6 of 9. However, more studies are needed to conclude on the validity properties of these assessment methods, and before evidence-based recommendations can be made for clinical use on the "best" assessment method for classifying GJH. © 2017 Wiley Periodicals, Inc....... for evaluating the methodological quality of the identified studies, all included studies were rated "fair" or "poor." Most studies were using BS, and for BS the reliability most of the studies showed limited positive to conflicting evidence, with some shortcomings on studies for the validity. The three other...

  16. An investigation on clinical, radiological and biochemical methods for assessing periodontitis activity

    International Nuclear Information System (INIS)

    Janssen, P.T.M.

    1987-01-01

    In order to recognize in which stage rapidly progressing destruction of periodontal ligament fibers occurs, a number of diagnostic methods are studied in this thesis. It turns out that the actual much utilized clinical methods can not be improved while radiological and biochemical diagnositic methods are much more promising. 106 refs.; 20 figs.; 36 tabs

  17. Methods in Clinical Pharmacology Series

    Science.gov (United States)

    Beaumont, Claire; Young, Graeme C; Cavalier, Tom; Young, Malcolm A

    2014-01-01

    Human radiolabel studies are traditionally conducted to provide a definitive understanding of the human absorption, distribution, metabolism and excretion (ADME) properties of a drug. However, advances in technology over the past decade have allowed alternative methods to be employed to obtain both clinical ADME and pharmacokinetic (PK) information. These include microdose and microtracer approaches using accelerator mass spectrometry, and the identification and quantification of metabolites in samples from classical human PK studies using technologies suitable for non-radiolabelled drug molecules, namely liquid chromatography-mass spectrometry and nuclear magnetic resonance spectroscopy. These recently developed approaches are described here together with relevant examples primarily from experiences gained in support of drug development projects at GlaxoSmithKline. The advantages of these study designs together with their limitations are described. We also discuss special considerations which should be made for a successful outcome to these new approaches and also to the more traditional human radiolabel study in order to maximize knowledge around the human ADME properties of drug molecules. PMID:25041729

  18. Role Models and Teachers: medical students perception of teaching-learning methods in clinical settings, a qualitative study from Sri Lanka.

    Science.gov (United States)

    Jayasuriya-Illesinghe, Vathsala; Nazeer, Ishra; Athauda, Lathika; Perera, Jennifer

    2016-02-09

    Medical education research in general, and those focusing on clinical settings in particular, have been a low priority in South Asia. This explorative study from 3 medical schools in Sri Lanka, a South Asian country, describes undergraduate medical students' experiences during their final year clinical training with the aim of understanding the teaching-learning experiences. Using qualitative methods we conducted an exploratory study. Twenty eight graduates from 3 medical schools participated in individual interviews. Interview recordings were transcribed verbatim and analyzed using qualitative content analysis method. Emergent themes reveled 2 types of teaching-learning experiences, role modeling, and purposive teaching. In role modelling, students were expected to observe teachers while they conduct their clinical work, however, this method failed to create positive learning experiences. The clinical teachers who predominantly used this method appeared to be 'figurative' role models and were not perceived as modelling professional behaviors. In contrast, purposeful teaching allowed dedicated time for teacher-student interactions and teachers who created these learning experiences were more likely to be seen as 'true' role models. Students' responses and reciprocations to these interactions were influenced by their perception of teachers' behaviors, attitudes, and the type of teaching-learning situations created for them. Making a distinction between role modeling and purposeful teaching is important for students in clinical training settings. Clinical teachers' awareness of their own manifest professional characterizes, attitudes, and behaviors, could help create better teaching-learning experiences. Moreover, broader systemic reforms are needed to address the prevailing culture of teaching by humiliation and subordination.

  19. A comparison of three clustering methods for finding subgroups in MRI, SMS or clinical data

    DEFF Research Database (Denmark)

    Kent, Peter; Jensen, Rikke K; Kongsted, Alice

    2014-01-01

    ). There is a scarcity of head-to-head comparisons that can inform the choice of which clustering method might be suitable for particular clinical datasets and research questions. Therefore, the aim of this study was to perform a head-to-head comparison of three commonly available methods (SPSS TwoStep CA, Latent Gold...... LCA and SNOB LCA). METHODS: The performance of these three methods was compared: (i) quantitatively using the number of subgroups detected, the classification probability of individuals into subgroups, the reproducibility of results, and (ii) qualitatively using subjective judgments about each program...... classify individuals into those subgroups. CONCLUSIONS: Our subjective judgement was that Latent Gold offered the best balance of sensitivity to subgroups, ease of use and presentation of results with these datasets but we recognise that different clustering methods may suit other types of data...

  20. Encountering aged care: a mixed methods investigation of medical students' clinical placement experiences.

    Science.gov (United States)

    Annear, Michael J; Lea, Emma; Lo, Amanda; Tierney, Laura; Robinson, Andrew

    2016-02-04

    Residential aged care is an increasingly important health setting due to population ageing and the increase in age-related conditions, such as dementia. However, medical education has limited engagement with this fast-growing sector and undergraduate training remains primarily focussed on acute presentations in hospital settings. Additionally, concerns have been raised about the adequacy of dementia-related content in undergraduate medical curricula, while research has found mixed attitudes among students towards the care of older people. This study explores how medical students engage with the learning experiences accessible in clinical placements in residential aged care facilities (RACFs), particularly exposure to multiple comorbidity, cognitive impairment, and palliative care. Fifth-year medical students (N = 61) completed five-day clinical placements at two Australian aged care facilities in 2013 and 2014. The placements were supported by an iterative yet structured program and academic teaching staff to ensure appropriate educational experiences and oversight. Mixed methods data were collected before and after the clinical placement. Quantitative data included surveys of dementia knowledge and questions about attitudes to the aged care sector and working with older adults. Qualitative data were collected from focus group discussions concerning medical student expectations, learning opportunities, and challenges to engagement. Pre-placement surveys identified good dementia knowledge, but poor attitudes towards aged care and older adults. Negative placement experiences were associated with a struggle to discern case complexity and a perception of an aged care placement as an opportunity cost associated with reduced hospital training time. Irrespective of negative sentiment, post-placement survey data showed significant improvements in attitudes to working with older people and dementia knowledge. Positive student experiences were explained by in

  1. Nurse teacher models in clinical education from the perspective of student nurses--A mixed method study.

    Science.gov (United States)

    Gustafsson, Margareta; Kullén Engström, Agneta; Ohlsson, Ulla; Sundler, Annelie J; Bisholt, Birgitta

    2015-12-01

    The aim was to describe and compare the clinical teacher's role in different models of clinical practice from the perspective of student nurses. The study took place in collaboration with two Swedish universities that applied different educational models in clinical practice. A mixed method approach was used. The quantitative part had a comparative design and the qualitative part had a descriptive design. The study group consisted of 114 student nurses (response rate 87%). Fifty-three of them had met clinical teachers employed at the university and not participating in the daily clinical work (University Nurse Teachers, UNTs), whilst 61 had met clinical teachers dividing their time between teaching and nursing (Clinical Nurse Teachers, CNTs). Eight students participated in the qualitative part of the study. A questionnaire including the CLES+T scale was used to ascertain the students' perception of the clinical teacher's role, complemented by interviews directed towards an enrichment of this perception. Students meeting CNTs agreed more strongly than those meeting UNTs that the teacher had the ability to help them integrate theory and practice. Whilst spontaneous meetings between students and CNTs occurred, students mostly met UNTs in seminars. Students meeting UNTs felt alone but did appreciate having someone outside the clinical environment to provide support if they did not get along with their preceptor. In the case of UNTs, it is important that they keep their knowledge of clinical issues updated and visit the clinical placement not only for seminars but also to give students emotional support. In the case of CNTs, it is important that they are members of the faculty at the university, take part in the planning of the clinical courses and are able to explain the learning goals to the students. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. First test of the prompt gamma ray timing method with heterogeneous targets at a clinical proton therapy facility

    International Nuclear Information System (INIS)

    Hueso-González, Fernando; Enghardt, Wolfgang; Golnik, Christian; Petzoldt, Johannes; Pausch, Guntram; Fiedler, Fine; Priegnitz, Marlen; Römer, Katja E; Wagner, Andreas; Janssens, Guillaume; Prieels, Damien; Smeets, Julien; Vander Stappen, François

    2015-01-01

    Ion beam therapy promises enhanced tumour coverage compared to conventional radiotherapy, but particle range uncertainties significantly blunt the achievable precision. Experimental tools for range verification in real-time are not yet available in clinical routine. The prompt gamma ray timing method has been recently proposed as an alternative to collimated imaging systems. The detection times of prompt gamma rays encode essential information about the depth-dose profile thanks to the measurable transit time of ions through matter. In a collaboration between OncoRay, Helmholtz-Zentrum Dresden-Rossendorf and IBA, the first test at a clinical proton accelerator (Westdeutsches Protonentherapiezentrum Essen, Germany) with several detectors and phantoms is performed. The robustness of the method against background and stability of the beam bunch time profile is explored, and the bunch time spread is characterized for different proton energies. For a beam spot with a hundred million protons and a single detector, range differences of 5 mm in defined heterogeneous targets are identified by numerical comparison of the spectrum shape. For higher statistics, range shifts down to 2 mm are detectable. A proton bunch monitor, higher detector throughput and quantitative range retrieval are the upcoming steps towards a clinically applicable prototype. In conclusion, the experimental results highlight the prospects of this straightforward verification method at a clinical pencil beam and settle this novel approach as a promising alternative in the field of in vivo dosimetry. (paper)

  3. Delayed-enhancement magnetic resonance imaging in patients with clinically suspected stress cardiomyopathy (Tako-Tsubo)

    International Nuclear Information System (INIS)

    Muellerleile, K.; Sultan, A.; Willems, S.; Lund, G.; Groth, M.; Adam, G.; Barmeyer, A.; Meinertz, T.; Koester, R.; Heitzer, T.

    2010-01-01

    To compare the ability of delayed-enhancement magnetic resonance imaging (DE-MRI) and other MRI and clinical parameters to identify diseases mimicking stress cardiomyopathy (SCM). The study included 14 consecutive patients fulfilling the American Heart Association (AHA) criteria for SCM with acute left ventricular dysfunction in the absence of coronary artery disease, triggered by psychological stress. The MRI protocol consisted of cine, T 2-weighted, first-pass-perfusion (FPP) and DE-MRI. Six patients with DE were classified as mimicking SCM (non-SCM) and 8 patients without DE as SCM. FPP defects were found in 4 patients with non-SCM and in none with SCM (p < 0.05). Myocardial edema was found in 5 patients with non-SCM and in 2 patients with SCM (p = ns). No significant differences in clinical findings such as ECG, cardiac markers and echocardiographic recovery of left ventricular function were found between patients with non-SCM and SCM. Non-SCM defined by DE-MRI is a frequent finding in patients fulfilling the AHA criteria for SCM. Clinical findings seem to be of limited value to differentiate between non-SCM and SCM. (orig.)

  4. Standardized patients in audiology: a proposal for a new method of evaluating clinical competence.

    Science.gov (United States)

    Dinsmore, Brooke Freeman; Bohnert, Carrie; Preminger, Jill E

    2013-05-01

    While accrediting organizations require AuD programs to provide evidence that their students are able to demonstrate knowledge and competencies in specific content areas, there are no generally accepted mechanisms for the assessment and the measurement of these proficiencies. We propose that AuD programs consider developing standardized patient (SP) cases in order to develop consistent summative assessment programs within and across universities. The purpose of this article is to provide a framework for establishing SP programs to evaluate competencies in AuD students by detailing the history of SP cases and their use, developing a rationale for this method of assessment, and outlining the steps for writing and implementing SP cases. Literature review. SPs have been used to assess clinical competence in medical students for over 50 yr. The prevalence of SP assessment in allied health professions (e.g., dentistry, psychology, pharmacy) has increased over the last two decades but has only gained a limited following in audiology. SP assessment has been implemented in medical education using the Objective Structured Clinical Examination, a multistation, timed exam that uses fictional cases to assess students' clinical abilities. To date, only one published report has been completed that evaluates the use of SPs to assess clinical abilities in audiology students. This article expands upon the work of English et al (2007) and their efforts to use SPs to evaluate counseling abilities. To this end, we describe the steps necessary to write a case, procedures to determine performance requirements, and the need to develop remediation plans. As an example, we include a case that we have developed in order to evaluate vestibular assessment and patient communication skills. Utilizing SP assessment in audiology education would provide useful means to evaluate competence in a uniform way. Future research is necessary to develop reliable and valid cases that may be implemented

  5. A scoping review of the potential for chart stimulated recall as a clinical research method.

    Science.gov (United States)

    Sinnott, Carol; Kelly, Martina A; Bradley, Colin P

    2017-08-22

    Chart-stimulated recall (CSR) is a case-based interviewing technique, which is used in the assessment of clinical decision-making in medical education and professional certification. Increasingly, clinical decision-making is a concern for clinical research in primary care. In this study, we review the prior application and utility of CSR as a technique for research interviews in primary care. Following Arksey & O'Malley's method for scoping reviews, we searched seven databases, grey literature, reference lists, and contacted experts in the field. We excluded studies on medical education or competence assessment. Retrieved citations were screened by one reviewer and full texts were ordered for all potentially relevant abstracts. Two researchers independently reviewed full texts and performed data extraction and quality appraisal if inclusion criteria were met. Data were collated and summarised using a published framework on the reporting of qualitative interview techniques, which was chosen a priori. The preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines informed the review report. From an initial list of 789 citations, eight studies using CSR in research interviews were included in the review: six from North America, one from the Netherlands, and one from Ireland. The most common purpose of included studies was to examine the influence of guidelines on physicians' decisions. The number of interviewees ranged from seven to twenty nine, while the number of charts discussed per interview ranged from one to twelve. CSR gave insights into physicians' reasoning for actions taken or not taken; the unrecorded social and clinical influences on decisions; and discrepancies between physicians' real and perceived practice. Ethical concerns and the training and influence of the researcher were poorly discussed in most of the studies. Potential pitfalls included the risk of recall, selection and observation biases. Despite the proven validity

  6. The REFER (REFer for EchocaRdiogram protocol: a prospective validation of a clinical decision rule, NT-proBNP, or their combination, in the diagnosis of heart failure in primary care. Rationale and design

    Directory of Open Access Journals (Sweden)

    Tait Lynda

    2012-10-01

    Full Text Available Abstract Background Heart failure is a major cause of mortality and morbidity. As mortality rates are high, it is important that patients seen by general practitioners with symptoms suggestive of heart failure are identified quickly and treated appropriately. Identifying patients with heart failure or deciding which patients need further tests is a challenge. All patients with suspected heart failure should be diagnosed using objective tests such as echocardiography, but it is expensive, often delayed, and limited by the significant skill shortage of trained echocardiographers. Alternative approaches for diagnosing heart failure are currently limited. Clinical decision tools that combine clinical signs, symptoms or patient characteristics are designed to be used to support clinical decision-making and validated according to strict methodological procedures. The REFER Study aims to determine the accuracy and cost-effectiveness of our previously derived novel, simple clinical decision rule, a natriuretic peptide assay, or their combination, in the triage for referral for echocardiography of symptomatic adult patients who present in general practice with symptoms suggestive of heart failure. Methods/design This is a prospective, Phase II observational, diagnostic validation study of a clinical decision rule, natriuretic peptides or their combination, for diagnosing heart failure in primary care. Consecutive adult primary care patients 55 years of age or over presenting to their general practitioner with a chief complaint of recent new onset shortness of breath, lethargy or peripheral ankle oedema of over 48 hours duration, with no obvious recurrent, acute or self-limiting cause will be enrolled. Our reference standard is based upon a three step expert specialist consensus using echocardiography and clinical variables and tests. Discussion Our clinical decision rule offers a potential solution to the diagnostic challenge of providing a timely and

  7. [Models, methods, clinical contents in the specialized degree in nursing sciences].

    Science.gov (United States)

    Zannini, Lucia

    2003-01-01

    The document presented is the result of a consensus conference where nurses involved in teaching, direct care and management discussed with professionals and experts of other disciplines on the role of the clinical teaching at specialistic level. Nursing education in fact recently underwent a re-organization therefore after the degree (first level) there is a second level (Specialistic degree and PhD) first and second level master courses. The main question of the consensus conference was if there is a role and what are the contents of clinical nursing to be taught at specialistic level. A consensus was reached on the importance of not separating the teaching of the methods from the contents of care, to allow the production of new knowledge relevant for patients' care. A nurse with a specialistic degree should be able to plan and implement innovative models of care based on scientific knowledge; to recognise unexpected and rapidly evolving problems; to plan and implement, in collaboration with other professionals, complex educational interventions; study and explore principles and theories of helping relationship. The differences in contents and methods of clinical teaching between master and specialistic degree need to be further discussed and explored.

  8. Physiology knowledge plays a role when novices learn technical echocardiography skills

    DEFF Research Database (Denmark)

    Nielsen, Dorte Guldbrand; Gøtzsche, Ole; Eika, Berit

    2010-01-01

    Purpose: Little is known about factors of relevance for achieving technical skills of echocardiography (TTE); one of the essential skills defined by the European Society of Cardiology Core Curriculum. In an earlier study we have shown that there is a strong correlation between physiology knowledge...... and interpretation skills of intermediately trained echocardiographers. This study investigates the role of physiology knowledge in the development of echocardiographic technical expertise. Methods: Forty-five physicians (15 novices, 15 intermediates and 15 experts) were evaluated on technical skills. Participants...... of echocardiography relevant physiology knowledge. Results: A strong and significant correlation between expertise level and technical checklist scores was found (r = .76, p

  9. 'Trial Exegesis': Methods for Synthesizing Clinical and Patient Reported Outcome (PRO Data in Trials to Inform Clinical Practice. A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Angus G K McNair

    Full Text Available The CONSORT extension for patient reported outcomes (PROs aims to improve reporting, but guidance on the optimal integration with clinical data is lacking. This study examines in detail the reporting of PROs and clinical data from randomized controlled trials (RCTs in gastro-intestinal cancer to inform design and reporting of combined PRO and clinical data from trials to improve the 'take home' message for clinicians to use in practice.The case study was undertaken in gastro-intestinal cancer trials. Well-conducted RCTs reporting PROs with validated instruments were identified and categorized into those combining PRO and clinical data in a single paper, or those separating data into linked primary and supplemental papers. Qualitative methods were developed to examine reporting of the critical interpretation of the trial results (trial exegesis in the papers in relation of the PRO and clinical outcomes and applied to each publication category. Results were used to inform recommendations for practice.From 1917 screened abstracts, 49 high quality RCTs were identified reported in 36 combined and 15 linked primary and supplemental papers. In-depth analysis of manuscript text identified three categories for understanding trial exegesis: where authors reported a "detailed", "general", or absent PRO rationale and integrated interpretation of clinical and PRO results. A total of 11 (30% and 6 (16% combined papers reported "detailed" PRO rationale and integrated interpretation of results although only 2 (14% and 1 (7% primary papers achieved the same standard respectively. Supplemental papers provide better information with 11 (73% and 3 (20% achieving "detailed" rationale and integrated interpretation of results. Supplemental papers, however, were published a median of 20 months after the primary RCT data in lower impact factor journals (median 16.8 versus 5.2.It is recommended that single papers, with detailed PRO rationale and integrated PRO and

  10. Incidental pulmonary embolism in cancer patients: clinical characteristics and outcome – a comprehensive cancer center experience

    Directory of Open Access Journals (Sweden)

    Abdel-Razeq H

    2011-03-01

    Full Text Available Hikmat N Abdel-Razeq1, Asem H Mansour2, Yousef M Ismael11Department of Internal Medicine, 2Department of Radiology, King Hussein Cancer Center, Amman, JordanBackground and objectives: Cancer patients undergo routine imaging studies much more than others. The widespread use of the recently introduced multi-detector CT scanners has resulted in an increasing number of incidentally diagnosed pulmonary embolism (PE in asymptomatic cancer patients. The significance and clinical outcome of such incidental PE is described.Methods: Both radiology department and hospital databases were searched for all cancer patients with a diagnosis of incidental PE. CT scans were performed using a 64-slice scanner with a 5.0 mm slice thickness.Results: During the study period, 34 patients with incidental PE were identified. The mean age (±SD was 57.7 (±12.4 years. All patients had active cancer, gastric, lung, colorectal, and lymphomas being the most frequent. Most patients had advanced-stage disease at the time of PE diagnosis; 26 (77% patients had stage IV, whereas only 3 patients had stages I or II disease. Twenty-seven (79% patients had their PE while undergoing active treatment with chemotherapy (68% or radiotherapy (12%; none, however, were on hormonal therapy. Most (74% patients had their PE diagnosed without history of recent hospital admission. Except for 5 (15%, all other patients were anticoagulated. With follow-up, 2 patients developed recurrent PE, 2 others had clinical and echocardiographic evidence of pulmonary hypertension, and 9 (26% died suddenly within 30 days of the diagnosis of incidental PE; 2 of these where among the 5 patients who were not anticoagulated.Conclusion: Incidental PE in cancer patients is increasingly encountered. Similar to symptomatic PE, many were diagnosed in patients with advanced stage disease and while undergoing active anti-cancer therapy. A significant percentage of patients had recurrent emboli, pulmonary hypertension

  11. The impact of case specificity and generalisable skills on clinical performance: a correlated traits-correlated methods approach.

    Science.gov (United States)

    Wimmers, Paul F; Fung, Cha-Chi

    2008-06-01

    The finding of case or content specificity in medical problem solving moved the focus of research away from generalisable skills towards the importance of content knowledge. However, controversy about the content dependency of clinical performance and the generalisability of skills remains. This study aimed to explore the relative impact of both perspectives (case specificity and generalisable skills) on different components (history taking, physical examination, communication) of clinical performance within and across cases. Data from a clinical performance examination (CPX) taken by 350 Year 3 students were used in a correlated traits-correlated methods (CTCM) approach using confirmatory factor analysis, whereby 'traits' refers to generalisable skills and 'methods' to individual cases. The baseline CTCM model was analysed and compared with four nested models using structural equation modelling techniques. The CPX consisted of three skills components and five cases. Comparison of the four different models with the least-restricted baseline CTCM model revealed that a model with uncorrelated generalisable skills factors and correlated case-specific knowledge factors represented the data best. The generalisable processes found in history taking, physical examination and communication were responsible for half the explained variance, in comparison with the variance related to case specificity. Conclusions Pure knowledge-based and pure skill-based perspectives on clinical performance both seem too one-dimensional and new evidence supports the idea that a substantial amount of variance contributes to both aspects of performance. It could be concluded that generalisable skills and specialised knowledge go hand in hand: both are essential aspects of clinical performance.

  12. Longitudinal left ventricular function for prediction of survival in systemic light-chain amyloidosis: incremental value compared with clinical and biochemical markers.

    Science.gov (United States)

    Buss, Sebastian J; Emami, Mostafa; Mereles, Derliz; Korosoglou, Grigorios; Kristen, Arnt V; Voss, Andreas; Schellberg, Dieter; Zugck, Christian; Galuschky, Christian; Giannitsis, Evangelos; Hegenbart, Ute; Ho, Anthony D; Katus, Hugo A; Schonland, Stefan O; Hardt, Stefan E

    2012-09-18

    The aim of the study was to determine whether longitudinal left ventricular (LV) function provides prognostic information in a large cohort of patients with systemic light-chain (AL) amyloidosis. AL amyloidosis is associated with a high incidence of cardiovascular events. Reduced myocardial longitudinal function is one of the hallmarks of myocardial involvement in this rare disease. Two hundred six consecutive patients with biopsy-proven AL amyloidosis were investigated in this prospective observational study. Echocardiographic imaging parameters, mean tissue Doppler-derived longitudinal strain (LS), and two-dimensional global longitudinal strain (2D-GLS) of the LV, cardiac serological biomarkers, and comprehensive clinical disease characteristics were assessed. The primary endpoint was all-cause mortality or heart transplantation. After a median follow-up of 1207 days, LS and 2D-GLS were significant predictors of survival in AL amyloidosis. The cutoff values discriminating survivors from nonsurvivors were -10.65% for LS and -11.78% for 2D-GLS. In a multivariable echocardiographic Cox model, only diastolic dysfunction and 2D-GLS remained as independent predictors of survival. In comprehensive clinical models, 2D-GLS (p < 0.0001), diastolic dysfunction (p < 0.01), the pathologic free light chains (p < 0.05), cardiac troponin-T (cTnT) (p < 0.01), and the Karnofsky index (p < 0.001) remained as independent predictors. 2D-GLS delineated a superior prognostic value compared with that derived from pathologic free light chains or cTnT in patients evaluated before firstline chemotherapy (n = 113; p < 0.0001), and remained the only independent predictor besides the Karnofsky index in subjects with preserved LV ejection fraction (≥50%; n = 127; p < 0.01). LS and 2D-GLS both offered significant incremental information (p < 0.001) for the assessment of outcome compared with clinical variables (age, Karnofsky index, and New York Heart Association functional class) and

  13. An Enzymatic Clinical Chemistry Laboratory Experiment Incorporating an Introduction to Mathematical Method Comparison Techniques

    Science.gov (United States)

    Duxbury, Mark

    2004-01-01

    An enzymatic laboratory experiment based on the analysis of serum is described that is suitable for students of clinical chemistry. The experiment incorporates an introduction to mathematical method-comparison techniques in which three different clinical glucose analysis methods are compared using linear regression and Bland-Altman difference…

  14. Nigerian Journal of Clinical Practice - Vol 20, No 6 (2017)

    African Journals Online (AJOL)

    The prevalence of metabolic syndrome and its components among overweight and ... Quantitative evaluation of the enamel caries which were treated with casein ... Assessment of gross malnutrition among primary school children using body mass ... Structural echocardiographic abnormalities seen in HIV/AIDS patients are ...

  15. A simplified method to recover urinary vesicles for clinical applications, and sample banking.

    Science.gov (United States)

    Musante, Luca; Tataruch, Dorota; Gu, Dongfeng; Benito-Martin, Alberto; Calzaferri, Giulio; Aherne, Sinead; Holthofer, Harry

    2014-12-23

    Urinary extracellular vesicles provide a novel source for valuable biomarkers for kidney and urogenital diseases: Current isolation protocols include laborious, sequential centrifugation steps which hampers their widespread research and clinical use. Furthermore, large individual urine sample volumes or sizable target cohorts are to be processed (e.g. for biobanking), the storage capacity is an additional problem. Thus, alternative methods are necessary to overcome such limitations. We have developed a practical vesicle isolation technique to yield easily manageable sample volumes in an exceptionally cost efficient way to facilitate their full utilization in less privileged environments and maximize the benefit of biobanking. Urinary vesicles were isolated by hydrostatic dialysis with minimal interference of soluble proteins or vesicle loss. Large volumes of urine were concentrated up to 1/100 of original volume and the dialysis step allowed equalization of urine physico-chemical characteristics. Vesicle fractions were found suitable to any applications, including RNA analysis. In the yield, our hydrostatic filtration dialysis system outperforms the conventional ultracentrifugation-based methods and the labour intensive and potentially hazardous step of ultracentrifugations are eliminated. Likewise, the need for trained laboratory personnel and heavy initial investment is avoided. Thus, our method qualifies as a method for laboratories working with urinary vesicles and biobanking.

  16. Barriers to and facilitators of independent non-medical prescribing in clinical practice: a mixed-methods systematic review

    Directory of Open Access Journals (Sweden)

    Timothy Noblet

    2017-10-01

    Registration: PROSPERO CRD42015017212. [Noblet T, Marriott J, Graham-Clarke E, Rushton A (2017 Barriers to and facilitators of independent non-medical prescribing in clinical practice: a mixed-methods systematic review. Journal of Physiotherapy 63: 221–234

  17. Echocardiographic Follow-Up of Patent Foramen Ovale and the Factors Affecting Spontaneous Closure.

    Science.gov (United States)

    Yildirim, Ali; Aydin, Alperen; Demir, Tevfik; Aydin, Fatma; Ucar, Birsen; Kilic, Zubeyir

    2016-11-01

    The aim of the present study was to evaluate the echocardiographic follow-up of patent foramen ovale, which is considered a potential etiological factor in various diseases, and to determine the factors affecting spontaneous closure. Between January 2000 and June 2012, records of 918 patients with patent foramen ovale were retrospectively reviewed. Patency of less than 3 mm around the fossa ovalis is called patent foramen ovale. Patients with cyanotic congenital heart diseases, severe heart valve disorders and severe hemodynamic left to right shunts were excluded from the study. The patients were divided into three groups based on age; 1 day-1 month in group 1, 1 month-12 months in group 2, and more than 12 months in group 3. Of the 918 patients, 564 (61.4%) had spontaneous closure, 328 (35.8%) had patent foramen ovale continued, 15 (1.6%) patients had patent foramen ovale enlarged to 3-5 mm, 6 patients were enlarged to 5-8 mm, and in one patient patent foramen ovale reached to more than 8 mm size. Defect was spontaneously closed in 65.9% of the patients in group 1, 66.7% of the patients in group 2, and 52.3% of the patients in group 3. There was a negative correlation between the age of diagnosis and spontaneous closure (p patent ductus arteriosus and atrial septal aneurysm did not have any effect on spontaneous closure of patent foramen ovale (p > 0.05). However, ventricular septal defect and spontaneous closure of patent foramen ovale had a positive correlation (p closure rate of patent foramen ovale is high. Furthermore, a positive correlation was found between spontaneous closure of patent foramen ovale with early diagnosis and small defect size.

  18. Effects of precompression on elasticity imaging of the breast: development of a clinically useful semiquantitative method of precompression assessment.

    Science.gov (United States)

    Barr, Richard G; Zhang, Zheng

    2012-06-01

    Elastography of the breast is a new technique for characterization of breast lesions. The reproducibility of elastographic techniques has been questioned. Precompression is known to effect elastographic results. This study determined the effect of precompression on clinical images and proposes a method to semiquantify the amount of precompression applied. Ten patients with different breast tissue types were evaluated with shear wave and strain elastography with varying amounts of precompression. The changes in the shear wave speed and images were documented. A semiquantitative method for determining the amount of precompression applied is presented. The reproducibility of the technique was determine by repeated measurements by 3 sonographers. Precompression substantially changes the elastographic results of patient images on both strain and shear wave elastography. Fat can have the same elasticity as cancer with clinically possible amounts of precompression. The proposed method for determining the amount of precompression applied has variability of less than 10%, which is within the error of the technique and would not affect clinical results. Four zones of precompression are identified, which are useful for explaining the effects of precompression on both strain and shear wave imaging. Precompression is a substantial factor in obtaining accurate results with elastography. A proposed simple, easily applied technique can be used to semiquantify the amount of precompression applied. Precompression should be minimized in obtaining breast clinical images.

  19. Differences in quantitative methods for measuring subjective cognitive decline - results from a prospective memory clinic study

    DEFF Research Database (Denmark)

    Vogel, Asmus; Salem, Lise Cronberg; Andersen, Birgitte Bo

    2016-01-01

    influence reports of cognitive decline. METHODS: The Subjective Memory Complaints Scale (SMC) and The Memory Complaint Questionnaire (MAC-Q) were applied in 121 mixed memory clinic patients with mild cognitive symptoms (mean MMSE = 26.8, SD 2.7). The scales were applied independently and raters were blinded...... decline. Depression scores were significantly correlated to both scales measuring subjective decline. Linear regression models showed that age did not have a significant contribution to the variance in subjective memory beyond that of depressive symptoms. CONCLUSIONS: Measures for subjective cognitive...... decline are not interchangeable when used in memory clinics and the application of different scales in previous studies is an important factor as to why studies show variability in the association between subjective cognitive decline and background data and/or clinical results. Careful consideration...

  20. Randomized Controlled Trial of Antiseptic Hand Hygiene Methods in an Outpatient Surgery Clinic.

    Science.gov (United States)

    Therattil, Paul J; Yueh, Janet H; Kordahi, Anthony M; Cherla, Deepa V; Lee, Edward S; Granick, Mark S

    2015-12-01

    Outpatient wound care plays an integral part in any plastic surgery practice. However, compliance with hand hygiene measures has shown to be low, due to skin irritation and lack of time. The objective of this trial was to determine whether single-use, long-acting antiseptics can be as effective as standard multiple-use hand hygiene methods in an outpatient surgical setting. A prospective, randomized controlled trial was performed in the authors' outpatient plastic surgery clinic at Rutgers New Jersey Medical School, Newark, NJ to compare the efficacy of an ethyl alcohol-based sanitizer (Avagard D Instant Hand Aniseptic, 3M Health Care, St. Paul, MN), a benzalkonium chloride-based sanitizer (Soft & Shield, Bioderm Technologies, Inc, Trenton, NJ, distributed by NAPP Technologies, Hackensack, NJ ), and soap and- water handwashing. Subjects included clinic personnel, who were followed throughout the course of a 3-hour clinic session with hourly hand bacterial counts taken. During the course of the trial, 95 subjects completed the clinic session utilizing 1 of the hand hygiene methods (36 ethyl alcohol-based sanitizer, 38 benzalkonium chloride-based sanitizer, and 21 soap-and-water handwashing). There was no difference between hand bacterial counts using the different methods at 4 hourly time points (P greater than 0.05). Hand bacterial counts increased significantly over the 3-hour clinic session with the ethyl alcohol-based sanitizer (9.24 to 21.90 CFU, P less than 0.05), benzalkonium chloride-based sanitizer (6.69 to 21.59 CFU, P less than 0.05), and soap-and-water handwashing (8.43 to 22.75 CFU, P less than 0.05). There does not appear to be any difference in efficacy between single-use, long-acting sanitizer, and standard multiple-use hand hygiene methods. Hand bacterial counts increased significantly over the course of the 3-hour clinic session regardless of the hand hygiene measure used. Hand condition of subjects was improved with the ethyl alcohol

  1. Avaliação ecocardiográfica em bezerros da raça Holandesa Echocardiographic evaluation in Holstein calves

    Directory of Open Access Journals (Sweden)

    Lilian E.S. Michima

    2007-12-01

    Full Text Available Com o objetivo de estabelecer valores de medidas ecocardiográficas em bezerros da raça Holandesa, utilizaram-se 25 animais, com idade entre 8 e 28 dias e peso entre 27 e 57 kg. Procedeu-se o exame ecocardiográfico em modo-B e modo-M para a obtenção dos valores médios dos seguintes parâmetros, em diástole e sístole, respectivamente: diâmetros internos dos ventrículos direito (2,05±0,13cm e 1,59±0,13cm e esquerdo (3,91±0,09cm e 2,52±0,13cm, espessuras do septo interventricular (1,24±0,04cm e 1,62±0,06cm e da parede livre do ventrículo esquerdo (0,92±0,04cm e 1,50±0,05cm. Obtiveram-se ainda valores do diâmetro dos átrios direito e esquerdo em sístole (2,97±0,12cm e 4,11±0,21cm, respectivamente, dos volumes diastólico (67,90±3,65ml, sistólico (25,32±3,05ml e de ejeção (42,58±2,46ml do ventrículo esquerdo, do débito cardíaco (3857±339ml/min, do diâmetro aórtico (2,52±0,05cm, da distância entre o ponto de maior abertura do folheto anterior da valva atrioventricular esquerda até o septo interventricular (0,65±0,08cm e tempo de ejeção (0,39±0,02s, das frações de encurtamento (36,27±2,40% e de ejeção do ventrículo esquerdo (64,67±3,22%. Houve média correlação linear positiva (66,4%, PWith the purpose of establishing echocardiographic measurements in Holstein calves, 25 calves, 8 to 28 days of age and body weight ranging from 27 to 57 kg, were used. The echocardiographic examination was proceeded in B and M-modes to obtain the following parameters, in diastole and systole: right ventricle (2.05±0.13cm and 1.59±0.13cm and left ventricle internal diameter (3.91±0.09cm and 2.52±0.13cm, and interventricular septum (1.24±0.04cm and 1.62±0.06cm and left ventricle free wall thickness (0.92±0.04cm and 1.50±0.05cm. The values for both left and right atria in systole were 2.97±0.12cm and 4.110.21cm, respectively. The left diastolic (67.90±3.65ml, systolic (25.32±3.05ml and ejection (42.58±2.46ml

  2. Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study).

    Science.gov (United States)

    Margossian, Renee; Schwartz, Marcy L; Prakash, Ashwin; Wruck, Lisa; Colan, Steven D; Atz, Andrew M; Bradley, Timothy J; Fogel, Mark A; Hurwitz, Lynne M; Marcus, Edward; Powell, Andrew J; Printz, Beth F; Puchalski, Michael D; Rychik, Jack; Shirali, Girish; Williams, Richard; Yoo, Shi-Joon; Geva, Tal

    2009-08-01

    Assessment of the size and function of a functional single ventricle (FSV) is a key element in the management of patients after the Fontan procedure. Measurement variability of ventricular mass, volume, and ejection fraction (EF) among observers by echocardiography and cardiac magnetic resonance imaging (CMR) and their reproducibility among readers in these patients have not been described. From the 546 patients enrolled in the Pediatric Heart Network Fontan Cross-Sectional Study (mean age 11.9 +/- 3.4 years), 100 echocardiograms and 50 CMR studies were assessed for measurement reproducibility; 124 subjects with paired studies were selected for comparison between modalities. Interobserver agreement for qualitative grading of ventricular function by echocardiography was modest for left ventricular (LV) morphology (kappa = 0.42) and weak for right ventricular (RV) morphology (kappa = 0.12). For quantitative assessment, high intraclass correlation coefficients were found for echocardiographic interobserver agreement (LV 0.87 to 0.92, RV 0.82 to 0.85) of systolic and diastolic volumes, respectively. In contrast, intraclass correlation coefficients for LV and RV mass were moderate (LV 0.78, RV 0.72). The corresponding intraclass correlation coefficients by CMR were high (LV 0.96, RV 0.85). Volumes by echocardiography averaged 70% of CMR values. Interobserver reproducibility for the EF was similar for the 2 modalities. Although the absolute mean difference between modalities for the EF was small (<2%), 95% limits of agreement were wide. In conclusion, agreement between observers of qualitative FSV function by echocardiography is modest. Measurements of FSV volume by 2-dimensional echocardiography underestimate CMR measurements, but their reproducibility is high. Echocardiographic and CMR measurements of FSV EF demonstrate similar interobserver reproducibility, whereas measurements of FSV mass and LV diastolic volume are more reproducible by CMR.

  3. Disease-specific clinical pathways - are they feasible in primary care? A mixed-methods study.

    Science.gov (United States)

    Grimsmo, Anders; Løhre, Audhild; Røsstad, Tove; Gjerde, Ingunn; Heiberg, Ina; Steinsbekk, Aslak

    2018-04-12

    To explore the feasibility of disease-specific clinical pathways when used in primary care. A mixed-method sequential exploratory design was used. First, merging and exploring quality interview data across two cases of collaboration between the specialist care and primary care on the introduction of clinical pathways for four selected chronic diseases. Secondly, using quantitative data covering a population of 214,700 to validate and test hypothesis derived from the qualitative findings. Primary care and specialist care collaborating to manage care coordination. Primary-care representatives expressed that their patients often have complex health and social needs that clinical pathways guidelines seldom consider. The representatives experienced that COPD, heart failure, stroke and hip fracture, frequently seen in hospitals, appear in low numbers in primary care. The quantitative study confirmed the extensive complexity among home healthcare nursing patients and demonstrated that, for each of the four selected diagnoses, a homecare nurse on average is responsible for preparing reception of the patient at home after discharge from hospital, less often than every other year. The feasibility of disease-specific pathways in primary care is limited, both from a clinical and organisational perspective, for patients with complex needs. The low prevalence in primary care of patients with important chronic conditions, needing coordinated care after hospital discharge, constricts transferring tasks from specialist care. Generic clinical pathways are likely to be more feasible and efficient for patients in this setting. Key points Clinical pathways in hospitals apply to single-disease guidelines, while more than 90% of the patients discharged to community health care for follow-up have multimorbidity. Primary care has to manage the health care of the patient holistically, with all his or her complex needs. Patients most frequently admitted to hospitals, i.e. patients with COPD

  4. A study on job satisfaction among clinical and non-clinical hospital ...

    African Journals Online (AJOL)

    Methods: Two hundred clinical and non-clinical hospital staff were invited to take part in the study. They completed a sociodemographic questionnaire and the Job Descriptive Index (JDI). Results: The results indicated that majority clinical and non-clinical staff were satisfied with their jobs as regards the parameters of the ...

  5. Clinical value of different detection methods in blunt ocular trauma

    Directory of Open Access Journals (Sweden)

    Yang Li

    2018-02-01

    Full Text Available Blunt ocular can cause persistent change of eye structure and function, the method of detection which is closely related to eye injury including B-can ultrasonography, UBM, OCT, FFA, scanning laser polarimetry, fundus autofluorescence, each examination with particular emphasis. This paper aims to review the advantages and disadvantages of different inspection methods in order to provide reference for clinical diagnosis and treatment of blunt ocular trauma.

  6. Echocardiographic estimation of acute haemodynamic response during optimization of multisite pace-maker using different pacing modalities and atrioventricular delays

    Directory of Open Access Journals (Sweden)

    Šalinger-Martinović Sonja

    2009-01-01

    Full Text Available Background/Aim. Cardiac resynchronization therapy (CRT improves ventricular dyssynchrony and is associated with an improvement in symptoms, quality of life and prognosis in patients with severe heart failure and intraventricular conduction delay. Different pacing modalities produce variable activation patterns and may be a cause of different haemodynamic changes. The aim of our study was to investigate acute haemodynamic changes with different CRT configurations during optimization procedure. Methods. This study included 30 patients with severe left ventricular systolic dysfunction and left bundle branch block with wide QRS (EF 24.33 ± 3.7%, QRS 159 ± 17.3 ms, New York Heart Association III/IV 25/5 with implanted CRT device. The whole group of patients had severe mitral regurgitation in order to measure dP/dt. After implantation and before discharge all the patients underwent optimization procedure guided by Doppler echocardiography. Left and right ventricular pre-ejection intervals (LVPEI and RVPEI, interventricular mechanical delay (IVD and the maximal rate of ventricular pressure rise during early systole (max dP/dt were measured during left and biventricular pacing with three different atrioventricular (AV delays. Results. After CRT device optimization, optimal AV delay and CRT mode were defined. Left ventricular pre-ejection intervals changed from 170.5 ± 24.6 to 145.9 ± 9.5 (p < 0.001, RVPEI from 102.4 ± 15.9 to 119.8 ± 10.9 (p < 0.001, IVD from 68.1 ± 18.3 to 26.5 ± 8.2 (p < 0.001 and dP/dt from 524.2 ± 67 to 678.2 ± 88.5 (p < 0.01. Conclusion. In patients receiving CRT echocardiographic assessment of the acute haemodynamic response to CRT is a useful tool in optimization procedure. The variability of Doppler parameters with different CRT modalities emphasizes the necessity of individualized approach in optimization procedure.

  7. A method for developing standardised interactive education for complex clinical guidelines

    Directory of Open Access Journals (Sweden)

    Vaughan Janet I

    2012-11-01

    Full Text Available Abstract Background Although systematic use of the Perinatal Society of Australia and New Zealand internationally endorsed Clinical Practice Guideline for Perinatal Mortality (PSANZ-CPG improves health outcomes, implementation is inadequate. Its complexity is a feature known to be associated with non-compliance. Interactive education is effective as a guideline implementation strategy, but lacks an agreed definition. SCORPIO is an educational framework containing interactive and didactic teaching, but has not previously been used to implement guidelines. Our aim was to transform the PSANZ-CPG into an education workshop to develop quality standardised interactive education acceptable to participants for learning skills in collaborative interprofessional care. Methods The workshop was developed using the construct of an educational framework (SCORPIO, the PSANZ-CPG, a transformation process and tutor training. After a pilot workshop with key target and stakeholder groups, modifications were made to this and subsequent workshops based on multisource written observations from interprofessional participants, tutors and an independent educator. This participatory action research process was used to monitor acceptability and educational standards. Standardised interactive education was defined as the attainment of content and teaching standards. Quantitative analysis of positive expressed as a percentage of total feedback was used to derive a total quality score. Results Eight workshops were held with 181 participants and 15 different tutors. Five versions resulted from the action research methodology. Thematic analysis of multisource observations identified eight recurring education themes or quality domains used for standardisation. The two content domains were curriculum and alignment with the guideline and the six teaching domains; overload, timing, didacticism, relevance, reproducibility and participant engagement. Engagement was the most

  8. Role of Negative Trans-Thoracic Echocardiography in the Diagnosis of Infective Endocarditis.

    Science.gov (United States)

    Leitman, Marina; Peleg, Eli; Shmueli, Ruthie; Vered, Zvi

    2016-07-01

    The search for the presence of vegetations in patients with suspected infective endocarditis is a major indication for trans-esophageal echocardiographic (TEE) examinations. Advances in harmonic imaging and ongoing improvement in modern echocardiographic systems allow adequate quality of diagnostic images in most patients. To investigate whether TEE examinations are always necessary for the assessment of patients with suspected infective endocarditis. During 2012-2014 230 trans-thoracic echo (TTE) exams in patients with suspected infective endocarditis were performed at our center. Demographic, epidemiological, clinical and echocardiographic data were collected and analyzed, and the final clinical diagnosis and outcome were determined. Of 230 patients, 24 had definite infective endocarditis by clinical assessment. TEE examination was undertaken in 76 of the 230 patients based on the clinical decision of the attending physician. All TTE exams were classified as: (i) positive, i.e., vegetations present; (ii) clearly negative; or (iii) non-conclusive. Of the 92 with clearly negative TTE exams, 20 underwent TEE and all were negative. All clearly negative patients had native valves, adequate quality images, and in all 92 the final diagnosis was not infective endocarditis. Thus, the negative predictive value of a clearly negative TTE examination was 100%. In patients with native cardiac valves referred for evaluation for infective endocarditis, an adequate quality TTE with clearly negative examination may be sufficient for the diagnosis.

  9. A systematic review and meta-analysis of online versus alternative methods for training licensed health care professionals to deliver clinical interventions

    Directory of Open Access Journals (Sweden)

    Helen Richmond

    2017-11-01

    Full Text Available Abstract Background Online training is growing in popularity and yet its effectiveness for training licensed health professionals (HCPs in clinical interventions is not clear. We aimed to systematically review the literature on the effectiveness of online versus alternative training methods in clinical interventions for licensed Health Care Professionals (HCPs on outcomes of knowledge acquisition, practical skills, clinical behaviour, self-efficacy and satisfaction. Methods Seven databases were searched for randomised controlled trials (RCTs from January 2000 to June 2015. Two independent reviewers rated trial quality and extracted trial data. Comparative effects were summarised as standardised mean differences (SMD and 95% confidence intervals. Pooled effect sizes were calculated using a random-effects model for three contrasts of online versus (i interactive workshops (ii taught lectures and (iii written/electronic manuals. Results We included 14 studies with a total of 1089 participants. Most trials studied medical professionals, used a workshop or lecture comparison, were of high risk of bias and had small sample sizes (range 21-183. Using the GRADE approach, we found low quality evidence that there was no difference between online training and an interactive workshop for clinical behaviour SMD 0.12 (95% CI -0.13 to 0.37. We found very low quality evidence of no difference between online methods and both a workshop and lecture for knowledge (workshop: SMD 0.04 (95% CI -0.28 to 0.36; lecture: SMD 0.22 (95% CI: -0.08, 0.51. Lastly, compared to a manual (n = 3/14, we found very low quality evidence that online methods were superior for knowledge SMD 0.99 (95% CI 0.02 to 1.96. There were too few studies to draw any conclusions on the effects of online training for practical skills, self-efficacy, and satisfaction across all contrasts. Conclusions It is likely that online methods may be as effective as alternative methods for training HCPs in

  10. A Novel Method to Generate and Expand Clinical-Grade, Genetically Modified, Tumor-Infiltrating Lymphocytes

    Directory of Open Access Journals (Sweden)

    Marie-Andrée Forget

    2017-08-01

    Full Text Available Following the clinical success achieved with the first generation of adoptive cell therapy (ACT utilizing in vitro expanded tumor-infiltrating lymphocytes (TILs, the second and third generations of TIL ACT are evolving toward the use of genetically modified TIL. TIL therapy generally involves the transfer of a high number of TIL, ranging from 109 to 1011 cells. One of the technical difficulties in genetically modifying TIL, using a retroviral vector, is the ability to achieve large expansion of transduced TIL, while keeping the technique suitable to a Good Manufacturing Practices (GMP environment. Consequently, we developed and optimized a novel method for the efficient production of large numbers of GMP-grade, gene-modified TIL for the treatment of patients with ACT. The chemokine receptor CXCR2 was used as the gene of interest for methodology development. The optimized procedure is currently used in the production of gene-modified TIL for two clinical trials for the treatment of metastatic melanoma at MD Anderson Cancer Center.

  11. The Infant with Aortic Arch Hypoplasia and Small Left Heart Structures: Echocardiographic Indices of Mitral and Aortic Hypoplasia Predicting Successful Biventricular Repair.

    Science.gov (United States)

    Plymale, Jennifer M; Frommelt, Peter C; Nugent, Melodee; Simpson, Pippa; Tweddell, James S; Shillingford, Amanda J

    2017-08-01

    In infants with aortic arch hypoplasia and small left-sided cardiac structures, successful biventricular repair is dependent on the adequacy of the left-sided structures. Defining accurate thresholds of echocardiographic indices predictive of successful biventricular repair is paramount to achieving optimal outcomes. We sought to identify pre-operative echocardiographic indices of left heart size that predict intervention-free survival in infants with small left heart structures undergoing primary aortic arch repair to establish biventricular circulation (BVC). Infants ≤2 months undergoing aortic arch repair from 1999 to 2010 with aortic and/or mitral valve hypoplasia, (Z-score ≤-2) were included. Pre-operative and follow-up echocardiograms were reviewed. Primary outcome was successful biventricular circulation (BVC), defined as freedom from death, transplant, or single ventricular conversion at 1 year. Need for catheter based or surgical re-intervention (RI), valve annular growth, and significant late aortic or mitral valve obstruction were additional outcomes. Fifty one of 73 subjects (79%) had successful BVC and were free of RI at 1 year. Seven subjects failed BVC; four of those died. The overall 1 year survival for the cohort was 95%. Fifteen subjects underwent a RI but maintained BVC. In univariate analysis, larger transverse aorta (p = 0.006) and aortic valve (p = 0.02) predicted successful BVC without RI. In CART analysis, the combination of mitral valve (MV) to tricuspid valve (TV) ratio ≤0.66 with an aortic valve (AV) annulus Z-score ≤-3 had the greatest power to predict BVC failure (sensitivity 71%, specificity 94%). In those with successful BVC, the combination of both AV and MV Z-score ≤-2.5 increased the odds of RI (OR 3.8; CI 1.3-11.4). Follow-up of non-RI subjects revealed improvement in AV and MV Z-score (median AV annulus changed over time from -2.34 to 0.04 (p indices. In this complex population, 1 year survival is high, but

  12. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  13. Clinical experience with the objective symmetry detector method for gammaencephalography

    International Nuclear Information System (INIS)

    Sachs, C.; Ericson, K.; Lind, M.

    1982-01-01

    The objective symmetry detector method for gammaencephalography previously described has been further developed. A rapid micro-computerized automatic measuring device has been constructed and the method used in screening of neurologic patients. The previously chosen classification boundaries between normal and pathologic isotope distributions were not entirely satisfactory for clinical screening of patients with neurologic symptoms. By use of new classification boundaries, 87 per cent of patients with brain tumours could be separated from patients with neurologic symptoms but without gross brain lesions and from neurologically healthy subjects. (Auth.)

  14. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  15. Transthoracic ultrasound guided balloon dilation of cor triatriatum dexter in 2 Rottweiler puppies.

    Science.gov (United States)

    Birettoni, F; Caivano, D; Bufalari, A; Giorgi, M E; Miglio, A; Paradies, P; Porciello, F

    2016-12-01

    Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Regional Longitudinal Myocardial Deformation Provides Incremental Prognostic Information in Patients with ST-Segment Elevation Myocardial Infarction.

    Directory of Open Access Journals (Sweden)

    Tor Biering-Sørensen

    Full Text Available Global longitudinal systolic strain (GLS has recently been demonstrated to be a superior prognosticator to conventional echocardiographic measures in patients after myocardial infarction (MI. The aim of this study was to evaluate the prognostic value of regional longitudinal myocardial deformation in comparison to GLS, conventional echocardiography and clinical information.In total 391 patients were admitted with ST-Segment elevation myocardial infarction (STEMI, treated with primary percutaneous coronary intervention and subsequently examined by echocardiography. All patients were examined by tissue Doppler imaging (TDI and two-dimensional strain echocardiography (2DSE.During a median-follow-up of 5.3 (IQR 2.5-6.1 years the primary endpoint (death, heart failure or a new MI was reached by 145 (38.9% patients. After adjustment for significant confounders (including conventional echocardiographic parameters and culprit lesion, reduced longitudinal performance in the anterior septal and inferior myocardial regions (but not GLS remained independent predictors of the combined outcome. Furthermore, inferior myocardial longitudinal deformation provided incremental prognostic information to clinical and conventional echocardiographic information (Harrell's c-statistics: 0.63 vs. 0.67, p = 0.032. In addition, impaired longitudinal deformation outside the culprit lesion perfusion region was significantly associated with an adverse outcome (p<0.05 for all deformation parameters.Regional longitudinal myocardial deformation measures, regardless if determined by TDI or 2DSE, are superior prognosticators to GLS. In addition, impaired longitudinal deformation in the inferior myocardial segment provides prognostic information over and above clinical and conventional echocardiographic risk factors. Furthermore, impaired longitudinal deformation outside the culprit lesion perfusion region seems to be a paramount marker of adverse outcome.

  17. Initial clinical experience with a novel biodegradable ring in patients with functional tricuspid insufficiency: Kalangos Biodegradable Tricuspid Ring.

    Science.gov (United States)

    Burma, O; Ustunsoy, H; Davutoglu, V; Celkan, M A; Kazaz, H; Pektok, E

    2007-08-01

    Tricuspid annuloplasty procedures have been widely performed in clinics for many years. The Kalangos Biodegradable Tricuspid Ring (Kalangos Biodegradable Tricuspid Ring, Bioring SA, Lonay, Switzerland) is a novel prosthesis for the treatment of tricuspid insufficiency. The aim of this study was to evaluate the clinical and echocardiographic results of this novel prosthesis for functional tricuspid insufficiency. Between October 2005 and May 2006, 15 patients with the diagnosis of moderate or severe functional tricuspid insufficiency were treated by implantation of a Kalangos Biodegradable Tricuspid Ring. All patients were evaluated clinically and by echocardiography preoperatively, and control tests were performed at the end of the 1st and 6th month following surgery. Moderate and severe insufficiency was documented in 11 and 4 patients, respectively, in the preoperative tests. 1 and 6 months after surgery, 4 patients had trace and 1 patient had mild tricuspid insufficiency, while 10 patients had none. At the 1st and 6th month follow-up, systolic pulmonary arterial pressure, right atrial dimension and right ventricular diastolic diameter were found to be significantly lower than the preoperative values ( P tricuspid valve area had decreased significantly at the end of the 1st month; however, no significant difference was found between the 1st and 6th month tests ( P > 0.05). Three-quarters of the annuloplasty ring had degraded at 6 months. No complications related to the prosthesis or the procedure occurred within this period. Kalangos Biodegradable Ring is a promising prosthesis in patients with functional tricuspid insufficiency, with encouraging initial results.

  18. Heart valve disease associated with treatment with ergot-derived dopamine agonists: a clinical and echocardiographic study of patients with Parkinson's disease

    DEFF Research Database (Denmark)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, E

    2007-01-01

    regurgitation (n = 5) was found in 22 EDDA patients (25.9%). Two patients had coexistent moderate mitral and tricuspid valvular regurgitation. Two non-EDDA patients had moderate valve insufficiency (3.8%, P insufficiency in the EDDA patients was 7....... Interventions. Patients were screened for valvular heart disease by clinical means and by examiner-blinded echocardiography. Main outcome measure was valvular regurgitation revealed by echocardiography. RESULTS: Severe aortic regurgitation (n = 4) or moderate aortic (n = 12), mitral (n = 3) or tricuspidal valve...

  19. 2013 update on congenital heart disease, clinical cardiology, heart failure, and heart transplant.

    Science.gov (United States)

    Subirana, M Teresa; Barón-Esquivias, Gonzalo; Manito, Nicolás; Oliver, José M; Ripoll, Tomás; Lambert, Jose Luis; Zunzunegui, José L; Bover, Ramon; García-Pinilla, José Manuel

    2014-03-01

    This article presents the most relevant developments in 2013 in 3 key areas of cardiology: congenital heart disease, clinical cardiology, and heart failure and transplant. Within the area of congenital heart disease, we reviewed contributions related to sudden death in adult congenital heart disease, the importance of specific echocardiographic parameters in assessing the systemic right ventricle, problems in patients with repaired tetralogy of Fallot and indication for pulmonary valve replacement, and confirmation of the role of specific factors in the selection of candidates for Fontan surgery. The most recent publications in clinical cardiology include a study by a European working group on correct diagnostic work-up in cardiomyopathies, studies on the cost-effectiveness of percutaneous aortic valve implantation, a consensus document on the management of type B aortic dissection, and guidelines on aortic valve and ascending aortic disease. The most noteworthy developments in heart failure and transplantation include new American guidelines on heart failure, therapeutic advances in acute heart failure (serelaxin), the management of comorbidities such as iron deficiency, risk assessment using new biomarkers, and advances in ventricular assist devices. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  20. Clinical way method in treatment of out-patients with ischemic heart disease after cardiosurgery

    Directory of Open Access Journals (Sweden)

    Vardosanidze S.L.

    2010-12-01

    Full Text Available 158 patients with ischemic heart disease (IHD have been understudy during the period of 12 months in out-patient conditions. After completion of the primary examination all the patients of basic group (118 patients received clinical way method of treatment. Patients of the comparison group (40 patients after provided treatment were cared by their local therapeutists (cardiologists. The findings proved the fact that treatment of patients after cardiosurgery by clinical way method in out-patient conditions enabled to raise patient motivation to treatment, thereby assisting them to feel better, promoting normalization of arterial pressure data. The research results stated that clinical way method of treatment may be considered as rational and effective

  1. Aortic obstruction: anatomy and echocardiography

    Directory of Open Access Journals (Sweden)

    Keirns Candace

    2006-09-01

    Full Text Available Abstract Echocardiography is a valuable non-invasive technique for identifying the site and type of aortic obstruction. Knowledge of the morphological details of each type of obstruction is the basis for correct interpretation of the diagnostic images and clinical decisions. This study was undertaken to correlate the echocardiographic images with anatomic specimens of equivalent valvular and supravalvular aortic obstruction. Specimens were part of the collection of the Department of Embryology. Fifty six patients were studied, and forty specimens with aortic obstruction were analyzed. Echocardiographic characteristics: Thirty one (55.3% patients were women and twenty five (44.7% men. Valvular aortic obstruction was found in Thirty six patients (64.3 % and supravalvular aortic obstruction in twenty (35.7%. Anatomic characteristics: Of the forty specimens examined, twenty one (52.5% had valvular aortic obstruction and nineteen (47.5% supravalvular aortic obstruction. The anatomoechocardiographic correlation clearly showed that the anatomic findings of the specimen hearts and aortas corresponded to echocardiographic images of valvular and supravalvular aortic obstruction and provided solid corroboration of echocardiographic diagnoses.

  2. Pulmonary Hypertension and Pulmonary Vasodilators.

    Science.gov (United States)

    Keller, Roberta L

    2016-03-01

    Pulmonary hypertension in the perinatal period can present acutely (persistent pulmonary hypertension of the newborn) or chronically. Clinical and echocardiographic diagnosis of acute pulmonary hypertension is well accepted but there are no broadly validated criteria for echocardiographic diagnosis of pulmonary hypertension later in the clinical course, although there are significant populations of infants with lung disease at risk for this diagnosis. Contributing cardiovascular comorbidities are common in infants with pulmonary hypertension and lung disease. It is not clear who should be treated without confirmation of pulmonary vascular disease by cardiac catheterization, with concurrent evaluation of any contributing cardiovascular comorbidities. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Dose escalation methods in phase I cancer clinical trials.

    Science.gov (United States)

    Le Tourneau, Christophe; Lee, J Jack; Siu, Lillian L

    2009-05-20

    Phase I clinical trials are an essential step in the development of anticancer drugs. The main goal of these studies is to establish the recommended dose and/or schedule of new drugs or drug combinations for phase II trials. The guiding principle for dose escalation in phase I trials is to avoid exposing too many patients to subtherapeutic doses while preserving safety and maintaining rapid accrual. Here we review dose escalation methods for phase I trials, including the rule-based and model-based dose escalation methods that have been developed to evaluate new anticancer agents. Toxicity has traditionally been the primary endpoint for phase I trials involving cytotoxic agents. However, with the emergence of molecularly targeted anticancer agents, potential alternative endpoints to delineate optimal biological activity, such as plasma drug concentration and target inhibition in tumor or surrogate tissues, have been proposed along with new trial designs. We also describe specific methods for drug combinations as well as methods that use a time-to-event endpoint or both toxicity and efficacy as endpoints. Finally, we present the advantages and drawbacks of the various dose escalation methods and discuss specific applications of the methods in developmental oncotherapeutics.

  4. [On academic thought and clinical application of LI Yan-Fang's middle-warmer energy method].

    Science.gov (United States)

    Li, Li-Jun

    2010-10-01

    The present paper introduces LI Yan-Fang's middle-warmer energy method from acupoint selection, needling methods, treatment principle and his clinical experiences in treatment of stroke and insomnia etc. The acupuncture prescription of this method consist of Shangwan (CV 13), Zhongwan (CV 12), Jianli (CV 11), Xiawan (CV 10), Shuifen (CV 9), Huangshu (KI 16) and Qihai (CV 6) etc as the main acupoints combined with strict manipulation and depth of needling to treat clinical diseases.

  5. Risk factors for pulmonary arterial hypertension in patients with tuberculosis-destroyed lungs and their clinical characteristics compared with patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Jo, Yong Suk; Park, Ju-Hee; Lee, Jung Kyu; Heo, Eun Young; Chung, Hee Soon; Kim, Deog Kyeom

    2017-01-01

    There are limited data on pulmonary arterial hypertension (PAH) in patients with tuberculosis-destroyed lung (TDL), a sequela of pulmonary tuberculosis. We identified the risk factors for PAH and their effects on acute exacerbation and mortality in patients with TDL, as well as the clinical differences in patients with chronic obstructive pulmonary disease (COPD) and PAH. A retrospective cohort study was conducted from 2010 through 2015 in a municipal referral hospital in South Korea. PAH was defined when echocardiographic pulmonary arterial pressure (PAP) was >40 mmHg. The clinical features and course of TDL patients with or without PAH were evaluated and differences between patients with COPD and PAH were analyzed. Among the 195 patients with TDL, echocardiographic data were available in 53 patients, and their mean PAP was 50.72±23.99 mmHg. The PAH group (n=37) had a smaller lung volume (forced vital capacity % predicted, 51.55% vs 72.37%, P <0.001) and more extensively destroyed lungs (3.27 lobes vs 2 lobes, P <0.001) than those in the non-PAH group (n=16). A higher PAP was significantly correlated with a higher frequency of acute exacerbation ( r =0.32, P =0.02). Multivariate analyses did not reveal any significant risk factors contributing to PAH in patients with TDL. Compared to COPD patients with PAH, TDL patients with PAH have smaller lung volume but a less severe airflow limitation. Tricuspid regurgitation and a D-shaped left ventricle during diastole were more frequently observed in TDL patients. The risk of exacerbation was not different between patients with PAH in COPD and TDL. PAH in patients with TDL was associated with severity of lung destruction but risk of exacerbation and mortality did not significantly differ between patients with PAH and without PAH.

  6. Long-term follow up after transcatheter closure of atrial septal defect and patent foramen ovale in adults

    Directory of Open Access Journals (Sweden)

    Jure Dolenc

    2014-01-01

    Full Text Available Background: The aim of our study was to define long-term electrocardiographic and echocardiographic changes and complications after transcatheter closure of atrial septal defect and patent foramen ovale in adults.Methods: The clinical, electrocardiographic and echocardiographic follow-up of 137 consecutive patients that underwent transcatheter closure of atrial septal defect (51 patients or patent foramen ovale (86 patients in a 10-year period was analyzed retrospectively.Results: In the patent foramen ovale group, we observed no significant postprocedural changes. There were no changes in heart rate, heart rhythm and PR or QRS duration in both groups. In the atrial septal defect group, we observed a leftward shift in the heart axis (p = 0.017, a decrease in the estimated systolic pulmonary artery pressure (p = 0.024, decreased tricuspid early diastolic flow velocity (p = 0.002, a decrease in the right chamber dimensions (p = 0.0004 and interventricular septal movement normalization (p < 0.0001. Most of the complications were mild and occurred early after the procedure. Three early serious complications were documented.Conclusions: No electrocardiographic or echocardiographic changes occurred after patent foramen ovale closure. Atrial septal defect closure is related to significant early morphological and hemodynamic improvement. Postprocedural complications are usually early and mild but serious late complications can occur. For that reason, long-term follow up is recommended in these patients.

  7. Standardizing Umbilical Cord Mesenchymal Stromal Cells for Translation to Clinical Use: Selection of GMP-Compliant Medium and a Simplified Isolation Method

    Directory of Open Access Journals (Sweden)

    J. Robert Smith

    2016-01-01

    Full Text Available Umbilical cord derived mesenchymal stromal cells (UC-MSCs are a focus for clinical translation but standardized methods for isolation and expansion are lacking. Previously we published isolation and expansion methods for UC-MSCs which presented challenges when considering good manufacturing practices (GMP for clinical translation. Here, a new and more standardized method for isolation and expansion of UC-MSCs is described. The new method eliminates dissection of blood vessels and uses a closed-vessel dissociation following enzymatic digestion which reduces contamination risk and manipulation time. The new method produced >10 times more cells per cm of UC than our previous method. When biographical variables were compared, more UC-MSCs per gram were isolated after vaginal birth compared to Caesarian-section births, an unexpected result. UC-MSCs were expanded in medium enriched with 2%, 5%, or 10% pooled human platelet lysate (HPL eliminating the xenogeneic serum components. When the HPL concentrations were compared, media supplemented with 10% HPL had the highest growth rate, smallest cells, and the most viable cells at passage. UC-MSCs grown in 10% HPL had surface marker expression typical of MSCs, high colony forming efficiency, and could undergo trilineage differentiation. The new protocol standardizes manufacturing of UC-MSCs and enables clinical translation.

  8. A systematic review and meta-analysis of online versus alternative methods for training licensed health care professionals to deliver clinical interventions.

    Science.gov (United States)

    Richmond, Helen; Copsey, Bethan; Hall, Amanda M; Davies, David; Lamb, Sarah E

    2017-11-23

    Online training is growing in popularity and yet its effectiveness for training licensed health professionals (HCPs) in clinical interventions is not clear. We aimed to systematically review the literature on the effectiveness of online versus alternative training methods in clinical interventions for licensed Health Care Professionals (HCPs) on outcomes of knowledge acquisition, practical skills, clinical behaviour, self-efficacy and satisfaction. Seven databases were searched for randomised controlled trials (RCTs) from January 2000 to June 2015. Two independent reviewers rated trial quality and extracted trial data. Comparative effects were summarised as standardised mean differences (SMD) and 95% confidence intervals. Pooled effect sizes were calculated using a random-effects model for three contrasts of online versus (i) interactive workshops (ii) taught lectures and (iii) written/electronic manuals. We included 14 studies with a total of 1089 participants. Most trials studied medical professionals, used a workshop or lecture comparison, were of high risk of bias and had small sample sizes (range 21-183). Using the GRADE approach, we found low quality evidence that there was no difference between online training and an interactive workshop for clinical behaviour SMD 0.12 (95% CI -0.13 to 0.37). We found very low quality evidence of no difference between online methods and both a workshop and lecture for knowledge (workshop: SMD 0.04 (95% CI -0.28 to 0.36); lecture: SMD 0.22 (95% CI: -0.08, 0.51)). Lastly, compared to a manual (n = 3/14), we found very low quality evidence that online methods were superior for knowledge SMD 0.99 (95% CI 0.02 to 1.96). There were too few studies to draw any conclusions on the effects of online training for practical skills, self-efficacy, and satisfaction across all contrasts. It is likely that online methods may be as effective as alternative methods for training HCPs in clinical interventions for the outcomes of knowledge

  9. Beyond discrimination: A comparison of calibration methods and clinical usefulness of predictive models of readmission risk.

    Science.gov (United States)

    Walsh, Colin G; Sharman, Kavya; Hripcsak, George

    2017-12-01

    Prior to implementing predictive models in novel settings, analyses of calibration and clinical usefulness remain as important as discrimination, but they are not frequently discussed. Calibration is a model's reflection of actual outcome prevalence in its predictions. Clinical usefulness refers to the utilities, costs, and harms of using a predictive model in practice. A decision analytic approach to calibrating and selecting an optimal intervention threshold may help maximize the impact of readmission risk and other preventive interventions. To select a pragmatic means of calibrating predictive models that requires a minimum amount of validation data and that performs well in practice. To evaluate the impact of miscalibration on utility and cost via clinical usefulness analyses. Observational, retrospective cohort study with electronic health record data from 120,000 inpatient admissions at an urban, academic center in Manhattan. The primary outcome was thirty-day readmission for three causes: all-cause, congestive heart failure, and chronic coronary atherosclerotic disease. Predictive modeling was performed via L1-regularized logistic regression. Calibration methods were compared including Platt Scaling, Logistic Calibration, and Prevalence Adjustment. Performance of predictive modeling and calibration was assessed via discrimination (c-statistic), calibration (Spiegelhalter Z-statistic, Root Mean Square Error [RMSE] of binned predictions, Sanders and Murphy Resolutions of the Brier Score, Calibration Slope and Intercept), and clinical usefulness (utility terms represented as costs). The amount of validation data necessary to apply each calibration algorithm was also assessed. C-statistics by diagnosis ranged from 0.7 for all-cause readmission to 0.86 (0.78-0.93) for congestive heart failure. Logistic Calibration and Platt Scaling performed best and this difference required analyzing multiple metrics of calibration simultaneously, in particular Calibration

  10. How to measure kyphosis in everyday clinical practice: a reliability study on different methods.

    Science.gov (United States)

    Zaina, Fabio; Donzelli, Sabrina; Lusini, Monia; Negrini, Stefano

    2012-01-01

    The sagittal plane measures have a relevant role both in Idiopathic Scoliosis (AIS) and in Hyperkyphosis (HK) management. Nevertheless, clinical tools for everyday use are scarce and not adequately studied. To assess the repeatability of different methods for the collection of the sagittal profile of patients with spinal deformities during everyday clinics. We performed 4 different studies in 4 different populations of AIS and HK patients. In the first study we reported the normative data and measurement error of the plumbline measures in a general population of 180 adolescents. In the second study we compared the sagittal distances from the plumbline of C7, T12, L3, and Sagittal Index (SI = C7+L3) with the measures of the Video Rasterstereography at the same levels and the angles of kyphosis and lordosis in 100 AIS patients. In the third study we evaluated the intra and inter-rater repeatability and the measurement error of kyphosis and lordosis angles measured with the Inclimed in 100 AIS patients. In the last study we evaluated the repeatability of the sagittal distances from the plumbline, by using a 1 mm change instead of 5 mm in a population of 40 patients. repeatability has been evaluated according to Bland and Altman, to identify the limits of variation that are clinically significant. Results. Study 1: the normative data were: females: 34 ± 11 mm for C7; 34 ± 15 mm for L3, males: 34 ± 10 mm for C7; 48 ± 10 mm for L3;. Study 2: a coefficient of correlation was calculated in order to compare measures. Study 3: the k value for Inclimed varied from fair to good. Study 4: the repeatability was fair for this measure. Some clinical instruments are now available for sagittal plane assessment in AIS and hyperkyphosis. The results of the present study report the limits during measurements in a clinical setting of parameters that are routinely collected by some clinicians.

  11. The summer institute in clinical dental research methods: still going and growing after twenty years.

    Science.gov (United States)

    Derouen, Timothy A; Wiesenbach, Carol

    2012-11-01

    The first Summer Institute in Clinical Dental Research Methods, a faculty development program at the University of Washington, was offered in the summer of 1992 for sixteen participants. The primary objective of the program was to give clinical faculty members in dentistry an introduction to and an understanding of the fundamental principles and methods used in good clinical research. In the twentieth offering of the institute in 2011, there were thirty-five participants, and over the twenty institutes, there has been a cumulative total of 463 participants who have come from thirty U.S. states as well as forty-three countries outside the United States. The curriculum has expanded from the initial offering of biostatistics, clinical epidemiology, behavioral research methods, and ethics in clinical research to now include clinical trials, grantsmanship, data analysis, an elective in molecular biology, and a team project that provides participants with hands-on experience in research proposal development as members of an interdisciplinary team. Enrollment has doubled since the first year, yet exit evaluations of the program content have remained consistently high (rated as very good to excellent). One of the indicators of program quality is that at least 50 percent of recent participants indicated that they attended because the program was recommended by colleagues who had attended. There seems to be an ever-increasing pool of dental faculty members who are eager to learn more about clinical research methodology through the institute despite the intensive demands of full-time participation in a six-week program.

  12. Would Socrates Have Actually Used the "Socratic Method" for Clinical Teaching?

    Science.gov (United States)

    Stoddard, Hugh A; O'Dell, David V

    2016-09-01

    Medical students and residents are familiar with clinical teaching methods in which a faculty member poses a series of questions to them. This technique is often called the "Socratic method," but it is frequently perceived by learners as an attempt to demean them, a practice that is colloquially known as "pimping." The distinction between Socratic teaching and pimping lies in the perception of "psychological safety." Psychological safety allows learners to answer questions or ask for help without threats to their dignity or worthiness. In a psychologically safe clinical teaching context, learners recognize that questions posed by attending physicians probe their current understanding and guide them to expand their knowledge. In pimping, questions are posed to embarrass the learner and to reinforce the teacher's position of power over them. Absent a threat of disparagement or condemnation, learners are able to focus on building schema for knowledge, skills, and attitudes, rather than worrying about shielding their self-worth. This article presents the proper Socratic method, as intended by Socrates, and contrasts it with pimping. This perspective defines psychological safety as the pivotal factor distinguishing Socratic teaching from pimping, and establishes the foundation for empirical studies of these common practices in medical education.

  13. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance.

    Science.gov (United States)

    Thanopoulos, Basil Vasilios D; Ninios, Vlassis; Dardas, Petros; Giannopoulos, Andreas; Deleanou, Dan; Iancovici, Silvia

    2016-11-15

    The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. A varying-coefficient method for analyzing longitudinal clinical trials data with nonignorable dropout

    Science.gov (United States)

    Forster, Jeri E.; MaWhinney, Samantha; Ball, Erika L.; Fairclough, Diane

    2011-01-01

    Dropout is common in longitudinal clinical trials and when the probability of dropout depends on unobserved outcomes even after conditioning on available data, it is considered missing not at random and therefore nonignorable. To address this problem, mixture models can be used to account for the relationship between a longitudinal outcome and dropout. We propose a Natural Spline Varying-coefficient mixture model (NSV), which is a straightforward extension of the parametric Conditional Linear Model (CLM). We assume that the outcome follows a varying-coefficient model conditional on a continuous dropout distribution. Natural cubic B-splines are used to allow the regression coefficients to semiparametrically depend on dropout and inference is therefore more robust. Additionally, this method is computationally stable and relatively simple to implement. We conduct simulation studies to evaluate performance and compare methodologies in settings where the longitudinal trajectories are linear and dropout time is observed for all individuals. Performance is assessed under conditions where model assumptions are both met and violated. In addition, we compare the NSV to the CLM and a standard random-effects model using an HIV/AIDS clinical trial with probable nonignorable dropout. The simulation studies suggest that the NSV is an improvement over the CLM when dropout has a nonlinear dependence on the outcome. PMID:22101223

  15. Value of information methods to design a clinical trial in a small population to optimise a health economic utility function

    Directory of Open Access Journals (Sweden)

    Michael Pearce

    2018-02-01

    Full Text Available Abstract Background Most confirmatory randomised controlled clinical trials (RCTs are designed with specified power, usually 80% or 90%, for a hypothesis test conducted at a given significance level, usually 2.5% for a one-sided test. Approval of the experimental treatment by regulatory agencies is then based on the result of such a significance test with other information to balance the risk of adverse events against the benefit of the treatment to future patients. In the setting of a rare disease, recruiting sufficient patients to achieve conventional error rates for clinically reasonable effect sizes may be infeasible, suggesting that the decision-making process should reflect the size of the target population. Methods We considered the use of a decision-theoretic value of information (VOI method to obtain the optimal sample size and significance level for confirmatory RCTs in a range of settings. We assume the decision maker represents society. For simplicity we assume the primary endpoint to be normally distributed with unknown mean following some normal prior distribution representing information on the anticipated effectiveness of the therapy available before the trial. The method is illustrated by an application in an RCT in haemophilia A. We explicitly specify the utility in terms of improvement in primary outcome and compare this with the costs of treating patients, both financial and in terms of potential harm, during the trial and in the future. Results The optimal sample size for the clinical trial decreases as the size of the population decreases. For non-zero cost of treating future patients, either monetary or in terms of potential harmful effects, stronger evidence is required for approval as the population size increases, though this is not the case if the costs of treating future patients are ignored. Conclusions Decision-theoretic VOI methods offer a flexible approach with both type I error rate and power (or equivalently

  16. Quantitative estimation of myocardial thickness by the wall thickness map with Tl-201 myocardial SPECT and its clinical use

    International Nuclear Information System (INIS)

    Sekiai, Yasuhiro; Sawai, Michihiko; Murayama, Susumu

    1988-01-01

    To estimate the wall thickness of left ventricular myocardium objectively and quantitatively, we adopted the device of wall thickness map (WTM) with Tl-201 myocardial SPECT. For validation on measuring left ventricular wall thickness with SPECT, fundamental studies were carried out with phantom models, and clinical studies were performed in 10 cases comparing the results from SPECT with those in echocardiography. To draw the WTM, left ventricular wall thickness was measured using the cut off method from SPECT images obtained at 5.6 mm intervals from the base and middle of left ventricle: short-axis image for the base and middle of left ventricle and vertical and horizontal long-axis images for the apical region. Wall thickness was defined from the number of pixel above the cut off level. Results of fundamental studies disclosed that it is impossible to evaluate the thickness of less than 10 mm by Tl-201 myocardial SPECT but possible to discriminate wall thickness of 10 mm, 15 mm, and 20 mm by Tl-201 myocardial SPECT. Echocardiographic results supported the validity of WTM, showing a good linear correlation (r = 0.96) between two methods on measuring wall thickness of left ventricle. We conclude that the WTM applied in this report may be useful for objective and quantitative estimation of myocardial hypertrophy. (author)

  17. Statistical methods for detecting differentially abundant features in clinical metagenomic samples.

    Directory of Open Access Journals (Sweden)

    James Robert White

    2009-04-01

    Full Text Available Numerous studies are currently underway to characterize the microbial communities inhabiting our world. These studies aim to dramatically expand our understanding of the microbial biosphere and, more importantly, hope to reveal the secrets of the complex symbiotic relationship between us and our commensal bacterial microflora. An important prerequisite for such discoveries are computational tools that are able to rapidly and accurately compare large datasets generated from complex bacterial communities to identify features that distinguish them.We present a statistical method for comparing clinical metagenomic samples from two treatment populations on the basis of count data (e.g. as obtained through sequencing to detect differentially abundant features. Our method, Metastats, employs the false discovery rate to improve specificity in high-complexity environments, and separately handles sparsely-sampled features using Fisher's exact test. Under a variety of simulations, we show that Metastats performs well compared to previously used methods, and significantly outperforms other methods for features with sparse counts. We demonstrate the utility of our method on several datasets including a 16S rRNA survey of obese and lean human gut microbiomes, COG functional profiles of infant and mature gut microbiomes, and bacterial and viral metabolic subsystem data inferred from random sequencing of 85 metagenomes. The application of our method to the obesity dataset reveals differences between obese and lean subjects not reported in the original study. For the COG and subsystem datasets, we provide the first statistically rigorous assessment of the differences between these populations. The methods described in this paper are the first to address clinical metagenomic datasets comprising samples from multiple subjects. Our methods are robust across datasets of varied complexity and sampling level. While designed for metagenomic applications, our software

  18. Assessing Clinical Significance: Does it Matter which Method we Use?

    Science.gov (United States)

    Atkins, David C.; Bedics, Jamie D.; Mcglinchey, Joseph B.; Beauchaine, Theodore P.

    2005-01-01

    Measures of clinical significance are frequently used to evaluate client change during therapy. Several alternatives to the original method devised by N. S. Jacobson, W. C. Follette, & D. Revenstorf (1984) have been proposed, each purporting to increase accuracy. However, researchers have had little systematic guidance in choosing among…

  19. Immediate, intermediate and long term clinical outcomes of percutaneous transvenous mitral commissurotomy

    Directory of Open Access Journals (Sweden)

    Satya Narayana Murthy Jayanthi Sriram

    2015-03-01

    Conclusions: MV score, Mitral valve area, mitral gradient and pulmonary artery pressures appeared to influence the outcome of PTMC. A clear-cut prospective assessment of individual components of the mitral valve apparatus using 3-D echocardiographic images may provide a more precise prediction of the PTMC outcome based on its morphological abnormalities.

  20. A neonate with mitral stenosis due to accessory mitral valve, ventricular septal defect, and patent ductus arteriosus: changes in echocardiographical findings during the neonatal period.

    Science.gov (United States)

    Ito, Tadahiko; Okubo, Tadashi

    2002-12-01

    A female neonate with mitral stenosis due to accessory mitral valve with ventricular septal defect and patent ductus arteriosus is described. She was referred to our hospital because of neonatal asphyxia. Asphyxia was improved by ventilator support, but rapid deterioration of respiration with pulmonary congestion and hemorrhage appeared 8 days after birth. Echocardiography revealed an accessory mitral valve attached to the anterior mitral leaflet with a perimembranous ventricular septal defect and patent ductus arteriosus. Although there were no echocardiographical findings indicating mitral stenosis on admission, the mitral stenosis blood flow patterns were detected by color and pulsed Doppler examination performed on the eighth day after admission. Transaortic resection of accessory mitral valve tissue was performed with patch closure of the ventricular septal defect and ligation of the ductus arteriosus 35 days after birth. After operation, pulmonary congestion and hemorrhage were improved. Postoperative echocardiography showed complete resection of the accessory mitral valve and no mitral insufficiency. We concluded that the combination of the accessory mitral valve and left-to-right shunt due to ventricular septal defect or patent ducturs arteriosus might have led to a critical hemodynamic condition due to relative mitral stenosis in the neonatal period with the decrease in pulmonary vascular resistance.

  1. Modelling transoesophageal echo

    Directory of Open Access Journals (Sweden)

    Susan Wright

    2011-04-01

    Full Text Available Background: Achieving competence in transoesophageal echocardiography (TOE requires a clear understanding of cardiac anatomy as well as an ability to correlate two-dimensional (2D echocardiographic images with the three-dimensional (3D structures which they represent. Training in the technique is a long process, which may also be hampered by insufficient access to teaching in the clinical environment. These challenges would be met by a simulator which demonstrates detailed cardiac anatomy with a previously unavailable degree of accuracy. Methods: A TOE simulator system was created by collaboration with a wide range of clinical specialists and a post-production company skilled in the generation of computer graphics and special effects for the film industry. The core of the system is an animated, accurate and detailed virtual heart. Echocardiographic simulation was developed to provide a real-time display of ultrasound images alongside the 3D anatomical correlate of the imaging plane. Results: A freely interactive animated model of the heart was created as the basis for ultrasound simulation. Creation of a mannequin simulator which drives the software allowed reproduction of the practical experience of the TOE procedure. Conclusions: Partnership with groups with a wide diversity of skills can result in a simulator teaching tool of high fidelity.

  2. The changing spectrum of rheumatic mitral regurgitation in Soweto, South Africa.

    Science.gov (United States)

    Meel, Ruchika; Peters, Ferande; Libhaber, Elena; Essop, Mohammed Rafique

    To determine the clinical and echocardiographic characteristics of contemporary patients with rheumatic mitral regurgitation (MR) at Chris Hani Baragwanath Academic Hospital. This prospective, cross-sectional study included 84 patients with isolated moderate or severe rheumatic MR who underwent clinical and echocardiographic assessment. Mean age of the patients was 44 ± 15.3 years (84% females). Acute rheumatic fever was rare. Hypertension and HIV were present in 52 and 26%, respectively. Echocardiography showed leaflet thickening and calcification, restricted motion and subvalvular disease in 41, 25 and 34%, respectively. Carpentier IIIa leaflet dysfunction occurred in 80% of patients and leaflet prolapse was seen in only 20%. These findings contrast with the previous literature, where patients were younger, they had rheumatic carditis and there were no co-morbidities. Leaflets were pliable, isolated leaflet prolapse was common and commissural fusion was absent. Contemporary patients with rheumatic MR were older, fewer had rheumatic fever and there were more co-morbidities. Echocardiographic features had evolved to greater leaflet thickening, calcification and reduced motion with minimal prolapse. These findings may have important implications for surgical management of this disease.

  3. ECG-derived spatial QRS-T angle is associated with ICD implantation, mortality and heart failure admissions in patients with LV systolic dysfunction.

    Directory of Open Access Journals (Sweden)

    Sarah Gleeson

    Full Text Available Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD therapy in patients with left ventricular systolic dysfunction (LVSD. We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF 31-40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention.534 patients ≤75 years of age with LVEF 31-40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes.49 patients (17% had events, defined as either mortality (n = 16 or ICD implantation for secondary prevention (n = 33. 72 parameters (58 A-ECG, 14 echocardiographic were univariately different (p110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4 for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9 for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease.Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.

  4. Value of information methods to design a clinical trial in a small population to optimise a health economic utility function.

    Science.gov (United States)

    Pearce, Michael; Hee, Siew Wan; Madan, Jason; Posch, Martin; Day, Simon; Miller, Frank; Zohar, Sarah; Stallard, Nigel

    2018-02-08

    Most confirmatory randomised controlled clinical trials (RCTs) are designed with specified power, usually 80% or 90%, for a hypothesis test conducted at a given significance level, usually 2.5% for a one-sided test. Approval of the experimental treatment by regulatory agencies is then based on the result of such a significance test with other information to balance the risk of adverse events against the benefit of the treatment to future patients. In the setting of a rare disease, recruiting sufficient patients to achieve conventional error rates for clinically reasonable effect sizes may be infeasible, suggesting that the decision-making process should reflect the size of the target population. We considered the use of a decision-theoretic value of information (VOI) method to obtain the optimal sample size and significance level for confirmatory RCTs in a range of settings. We assume the decision maker represents society. For simplicity we assume the primary endpoint to be normally distributed with unknown mean following some normal prior distribution representing information on the anticipated effectiveness of the therapy available before the trial. The method is illustrated by an application in an RCT in haemophilia A. We explicitly specify the utility in terms of improvement in primary outcome and compare this with the costs of treating patients, both financial and in terms of potential harm, during the trial and in the future. The optimal sample size for the clinical trial decreases as the size of the population decreases. For non-zero cost of treating future patients, either monetary or in terms of potential harmful effects, stronger evidence is required for approval as the population size increases, though this is not the case if the costs of treating future patients are ignored. Decision-theoretic VOI methods offer a flexible approach with both type I error rate and power (or equivalently trial sample size) depending on the size of the future population for

  5. Leadership of healthcare commissioning networks in England: a mixed-methods study on clinical commissioning groups

    Science.gov (United States)

    Zachariadis, Markos; Oborn, Eivor; Barrett, Michael; Zollinger-Read, Paul

    2013-01-01

    Objective To explore the relational challenges for general practitioner (GP) leaders setting up new network-centric commissioning organisations in the recent health policy reform in England, we use innovation network theory to identify key network leadership practices that facilitate healthcare innovation. Design Mixed-method, multisite and case study research. Setting Six clinical commissioning groups and local clusters in the East of England area, covering in total 208 GPs and 1 662 000 population. Methods Semistructured interviews with 56 lead GPs, practice managers and staff from the local health authorities (primary care trusts, PCT) as well as various healthcare professionals; 21 observations of clinical commissioning group (CCG) board and executive meetings; electronic survey of 58 CCG board members (these included GPs, practice managers, PCT employees, nurses and patient representatives) and subsequent social network analysis. Main outcome measures Collaborative relationships between CCG board members and stakeholders from their healthcare network; clarifying the role of GPs as network leaders; strengths and areas for development of CCGs. Results Drawing upon innovation network theory provides unique insights of the CCG leaders’ activities in establishing best practices and introducing new clinical pathways. In this context we identified three network leadership roles: managing knowledge flows, managing network coherence and managing network stability. Knowledge sharing and effective collaboration among GPs enable network stability and the alignment of CCG objectives with those of the wider health system (network coherence). Even though activities varied between commissioning groups, collaborative initiatives were common. However, there was significant variation among CCGs around the level of engagement with providers, patients and local authorities. Locality (sub) groups played an important role because they linked commissioning decisions with

  6. 23. Epidemiological aspects and clinical outcomes of mitral valve prolapse in Saudi adults over a 10 year period

    Directory of Open Access Journals (Sweden)

    A. alkahtani

    2016-07-01

    Full Text Available Mitral valve prolapse (MVP is a well recognized clinical entity that is associated with significant morbidity. Epidemiology, echocardiographic (echo characteristics and clinical outcome of MVP in Saudi Arabia have not been studied. To determine the prevalence, echo features and clinical outcome of MVP among the adult Saudi patients who underwent echo evaluation over a 10-year period.Retrospective review of consecutive cases of MVP or any of its components as diagnose by echocardiogram. Study was conducted in King Abdulaziz Cardiac Center, Riyadh and included 121,419 adult echo studies done between January 2003 and December 2012. Study population consisted of 77,176 patients after removing duplicate studies. Echo parameters for all Saudi nationals ⩾14 y of age were collected from the Xcelera database. Mitral valve disease due to non-myxomatous prolapse were excluded. Among the study population (n = 77,176 600 patients were labled as having MVP or any of its echo features (0.7%. Mean age was 64 years and 62% were males. Majority of patients (54.4% had mild MVP, while moderate and severe prolapse were present in 21.1% and 24.5% respectively. Severe mitral regurgitation was present in 16.5% and chordal rupture was noted in 9%. Left ventricular size was moderately dilated in 7.6% and severely dilated in 1.3%.Prevalence of MVP in Saudi nationals at a referral cardiac center is less than the reported international figure of 1-3%. In contrary to published literature MVP in Saudi population seems to be more common in males and seems to be diagnosed at a later age.

  7. Successful Tricuspid Valve Replacement in a Patient with Severe Pulmonary Arterial Hypertension and Preserved Right Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Jamil A. Aboulhosn

    2009-01-01

    Full Text Available A 56-year-old patient with severe pulmonary hypertension developed severe tricuspid regurgitation, right-sided heart failure, and congestive hepatopathy. She was transferred for possible lung transplant and/or tricuspid valve surgery. Clinical and echocardiographic assessment provided confidence that acute tricuspid valve failure was responsible for the decompensation and that tricuspid valve replacement despite pulmonary hypertension could be performed.

  8. Clinical implementation of a GPU-based simplified Monte Carlo method for a treatment planning system of proton beam therapy

    International Nuclear Information System (INIS)

    Kohno, R; Hotta, K; Nishioka, S; Matsubara, K; Tansho, R; Suzuki, T

    2011-01-01

    We implemented the simplified Monte Carlo (SMC) method on graphics processing unit (GPU) architecture under the computer-unified device architecture platform developed by NVIDIA. The GPU-based SMC was clinically applied for four patients with head and neck, lung, or prostate cancer. The results were compared to those obtained by a traditional CPU-based SMC with respect to the computation time and discrepancy. In the CPU- and GPU-based SMC calculations, the estimated mean statistical errors of the calculated doses in the planning target volume region were within 0.5% rms. The dose distributions calculated by the GPU- and CPU-based SMCs were similar, within statistical errors. The GPU-based SMC showed 12.30–16.00 times faster performance than the CPU-based SMC. The computation time per beam arrangement using the GPU-based SMC for the clinical cases ranged 9–67 s. The results demonstrate the successful application of the GPU-based SMC to a clinical proton treatment planning. (note)

  9. Recent advances in echocardiography: strain and strain rate imaging [version 1; referees: 3 approved

    Directory of Open Access Journals (Sweden)

    Oana Mirea

    2016-04-01

    Full Text Available Deformation imaging by echocardiography is a well-established research tool which has been gaining interest from clinical cardiologists since the introduction of speckle tracking. Post-processing of echo images to analyze deformation has become readily available at the fingertips of the user. New parameters such as global longitudinal strain have been shown to provide added diagnostic value, and ongoing efforts of the imaging societies and industry aimed at harmonizing methods will improve the technique further. This review focuses on recent advances in the field of echocardiographic strain and strain rate imaging, and provides an overview on its current and potential future clinical applications.

  10. Continual reassessment method for dose escalation clinical trials in oncology: a comparison of prior skeleton approaches using AZD3514 data.

    Science.gov (United States)

    James, Gareth D; Symeonides, Stefan N; Marshall, Jayne; Young, Julia; Clack, Glen

    2016-08-31

    The continual reassessment method (CRM) requires an underlying model of the dose-toxicity relationship ("prior skeleton") and there is limited guidance of what this should be when little is known about this association. In this manuscript the impact of applying the CRM with different prior skeleton approaches and the 3 + 3 method are compared in terms of ability to determine the true maximum tolerated dose (MTD) and number of patients allocated to sub-optimal and toxic doses. Post-hoc dose-escalation analyses on real-life clinical trial data on an early oncology compound (AZD3514), using the 3 + 3 method and CRM using six different prior skeleton approaches. All methods correctly identified the true MTD. The 3 + 3 method allocated six patients to both sub-optimal and toxic doses. All CRM approaches allocated four patients to sub-optimal doses. No patients were allocated to toxic doses from sigmoidal, two from conservative and five from other approaches. Prior skeletons for the CRM for phase 1 clinical trials are proposed in this manuscript and applied to a real clinical trial dataset. Highly accurate initial skeleton estimates may not be essential to determine the true MTD, and, as expected, all CRM methods out-performed the 3 + 3 method. There were differences in performance between skeletons. The choice of skeleton should depend on whether minimizing the number of patients allocated to suboptimal or toxic doses is more important. NCT01162395 , Trial date of first registration: July 13, 2010.

  11. Linking a research register to clinical records in older adults' mental health services:a mixed-methods study

    OpenAIRE

    Robotham, Dan; Evans, Joanne; Watson, Andrew; Perdue, Iain; Craig, Thomas; Rose, Diana; Wykes, Til

    2015-01-01

    INTRODUCTION: Patients can provide consent to have their clinical records linked to a research register, a process known as consent for contact (C4C). There is evidence about how to engage people with mental illness in C4C, but nothing specific to older adults. This is a priority area for research (for example, dementia trials), although sign-up rates to C4C are lower than for younger populations. Through this study we seek to understand these disparities.METHODS: This was a two-stage cross-s...

  12. Self-regulation method: psychological, physiological and clinical considerations. An overview.

    Science.gov (United States)

    Ikemi, A; Tomita, S; Kuroda, M; Hayashida, Y; Ikemi, Y

    1986-01-01

    Body-oriented therapies as relaxation training and certain forms of meditation are gaining popularity in the treatment and prevention of psychosomatic disorders. In this paper, a new method of self-control called self-regulation method (SRM), derived from autogenic training and Zen meditation, is presented. The technique of SRM is introduced. Secondly, physiological studies on SRM using skin temperature, galvanic skin response, and cortical evoked potentials are presented. Thirdly, the results of psychological tests conducted on SRM are presented. These psycho-physiological studies suggest that SRM may elicit a state of 'relaxed alertness'. Fourthly, clinical applications of SRM are discussed, and 3 cases are presented. Finally, SRM is discussed in relation to the psychology and physiology of 'relaxed alertness'.

  13. Unsupported valvuloplasty in children with congenital mitral valve anomalies. Late clinical results

    Directory of Open Access Journals (Sweden)

    Lorier Gabriel

    2001-01-01

    Full Text Available OBJECTIVE: To analyze late clinical evolution after surgical treatment of children, with reparative and reconstructive techniques without annular support. METHODS: We evaluated 21 patients operated upon between 1975 and 1998. Age 4.67±3.44 years; 47.6% girls; mitral insufficiency 57.1% (12 cases, stenosis 28.6% (6 cases, and double lesion 14.3% (3 cases. The perfusion 43.10±9.50min, and ischemia time were 29.40±10.50min. The average clinical follow-up in mitral insufficiency was 41.52±53.61 months. In the stenosis group (4 patients was 46.39±32.02 months, and in the double lesion group (3 patients, 39.41±37.5 months. The echocardiographic follow-up was in mitral insufficiency 37.17±39.51 months, stenosis 42.61±30.59 months, and in the double lesion 39.41±37.51 months. RESULTS: Operative mortality was 9.5% (2 cases. No late deaths occurred. In the group with mitral insufficiency, 10 (83.3% patients were asymptomatic (p=0.04. The majorit y with mild reflux (p=0.002. In the follow-up of the stenosis group, all were in functional class I (NYHA; and the mean transvalve gradient varied between 8 and 12mmHg, average of 10.7mmHg. In the double lesion group, 1 patient was reoperated at 43 months. No endocarditis or thromboembolism were reported. CONCLUSION: Mitral stenosis repair has worse late results, related to the valve abnormalities and associated lesions. The correction of mitral insufficiency without annular support showed good long-term results.

  14. Supervised methods for detection and segmentation of tissues in clinical lumbar MRI.

    Science.gov (United States)

    Ghosh, Subarna; Chaudhary, Vipin

    2014-10-01

    Lower back pain (LBP) is widely prevalent all over the world and more than 80% of the people suffer from LBP at some point of their lives. Moreover, a shortage of radiologists is the most pressing cause for the need of CAD (computer-aided diagnosis) systems. Automatic localization and labeling of intervertebral discs from lumbar MRI is the first step towards computer-aided diagnosis of lower back ailments. Subsequently, for diagnosis and characterization (quantification and localization) of abnormalities like disc herniation and stenosis, a completely automatic segmentation of intervertebral discs and the dural sac is extremely important. Contribution of this paper towards clinical CAD systems is two-fold. First, we propose a method to automatically detect all visible intervertebral discs in clinical sagittal MRI using heuristics and machine learning techniques. We provide a novel end-to-end framework that outputs a tight bounding box for each disc, instead of simply marking the centroid of discs, as has been the trend in the recent past. Second, we propose a method to simultaneously segment all the tissues (vertebrae, intervertebral disc, dural sac and background) in a lumbar sagittal MRI, using an auto-context approach instead of any explicit shape features or models. Past work tackles the lumbar segmentation problem on a tissue/organ basis, and which tend to perform poorly in clinical scans due to high variability in appearance. We, on the other hand, train a series of robust classifiers (random forests) using image features and sparsely sampled context features, which implicitly represent the shape and configuration of the image. Both these methods have been tested on a huge clinical dataset comprising of 212 cases and show very promising results for both disc detection (98% disc localization accuracy and 2.08mm mean deviation) and sagittal MRI segmentation (dice similarity indices of 0.87 and 0.84 for the dural sac and the inter-vertebral disc, respectively

  15. Clinical diagnostic of pleural effusions using a high-speed viscosity measurement method

    Science.gov (United States)

    Hurth, Cedric; Klein, Katherine; van Nimwegen, Lena; Korn, Ronald; Vijayaraghavan, Krishnaswami; Zenhausern, Frederic

    2011-08-01

    We present a novel bio-analytical method to discriminate between transudative and exudative pleural effusions based on a high-speed video analysis of a solid glass sphere impacting a liquid. Since the result depends on the solution viscosity, it can ultimately replace the battery of biochemical assays currently used. We present results obtained on a series of 7 pleural effusions obtained from consenting patients by analyzing both the splash observed after the glass impactor hits the liquid surface, and in a configuration reminiscent of the drop ball viscometer with added sensitivity and throughput provided by the high-speed camera. The results demonstrate distinction between the pleural effusions and good correlation with the fluid chemistry analysis to accurately differentiate exudates and transudates for clinical purpose. The exudative effusions display a viscosity around 1.39 ± 0.08 cP whereas the transudative effusion was measured at 0.89 ± 0.09 cP, in good agreement with previous reports.

  16. Task shifting to clinical officer-led echocardiography screening for detecting rheumatic heart disease in Malawi, Africa.

    Science.gov (United States)

    Sims Sanyahumbi, Amy; Sable, Craig A; Karlsten, Melissa; Hosseinipour, Mina C; Kazembe, Peter N; Minard, Charles G; Penny, Daniel J

    2017-08-01

    Echocardiographic screening for rheumatic heart disease in asymptomatic children may result in early diagnosis and prevent progression. Physician-led screening is not feasible in Malawi. Task shifting to mid-level providers such as clinical officers may enable more widespread screening. Hypothesis With short-course training, clinical officers can accurately screen for rheumatic heart disease using focussed echocardiography. A total of eight clinical officers completed three half-days of didactics and 2 days of hands-on echocardiography training. Clinical officers were evaluated by performing screening echocardiograms on 20 children with known rheumatic heart disease status. They indicated whether children should be referred for follow-up. Referral was indicated if mitral regurgitation measured more than 1.5 cm or there was any measurable aortic regurgitation. The κ statistic was calculated to measure referral agreement with a paediatric cardiologist. Sensitivity and specificity were estimated using a generalised linear mixed model, and were calculated on the basis of World Heart Federation diagnostic criteria. The mean κ statistic comparing clinical officer referrals with the paediatric cardiologist was 0.72 (95% confidence interval: 0.62, 0.82). The κ value ranged from a minimum of 0.57 to a maximum of 0.90. For rheumatic heart disease diagnosis, sensitivity was 0.91 (95% confidence interval: 0.86, 0.95) and specificity was 0.65 (95% confidence interval: 0.57, 0.72). There was substantial agreement between clinical officers and paediatric cardiologists on whether to refer. Clinical officers had a high sensitivity in detecting rheumatic heart disease. With short-course training, clinical officer-led echo screening for rheumatic heart disease is a viable alternative to physician-led screening in resource-limited settings.

  17. Validation of the tool assessment of clinical education (AssCE): A study using Delphi method and clinical experts.

    Science.gov (United States)

    Löfmark, Anna; Mårtensson, Gunilla

    2017-03-01

    The aim of the present study was to establish the validity of the tool Assessment of Clinical Education (AssCE). The tool is widely used in Sweden and some Nordic countries for assessing nursing students' performance in clinical education. It is important that the tools in use be subjected to regular audit and critical reviews. The validation process, performed in two stages, was concluded with a high level of congruence. In the first stage, Delphi technique was used to elaborate the AssCE tool using a group of 35 clinical nurse lecturers. After three rounds, we reached consensus. In the second stage, a group of 46 clinical nurse lecturers representing 12 universities in Sweden and Norway audited the revised version of the AssCE in relation to learning outcomes from the last clinical course at their respective institutions. Validation of the revised AssCE was established with high congruence between the factors in the AssCE and examined learning outcomes. The revised AssCE tool seems to meet its objective to be a validated assessment tool for use in clinical nursing education. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A simple, rapid and validated high-performance liquid chromatography method suitable for clinical measurements of human mercaptalbumin and non-mercaptalbumin.

    Science.gov (United States)

    Yasukawa, Keiko; Shimosawa, Tatsuo; Okubo, Shigeo; Yatomi, Yutaka

    2018-01-01

    Background Human mercaptalbumin and human non-mercaptalbumin have been reported as markers for various pathological conditions, such as kidney and liver diseases. These markers play important roles in redox regulations throughout the body. Despite the recognition of these markers in various pathophysiologic conditions, the measurements of human mercaptalbumin and non-mercaptalbumin have not been popular because of the technical complexity and long measurement time of conventional methods. Methods Based on previous reports, we explored the optimal analytical conditions for a high-performance liquid chromatography method using an anion-exchange column packed with a hydrophilic polyvinyl alcohol gel. The method was then validated using performance tests as well as measurements of various patients' serum samples. Results We successfully established a reliable high-performance liquid chromatography method with an analytical time of only 12 min per test. The repeatability (within-day variability) and reproducibility (day-to-day variability) were 0.30% and 0.27% (CV), respectively. A very good correlation was obtained with the results of the conventional method. Conclusions A practical method for the clinical measurement of human mercaptalbumin and non-mercaptalbumin was established. This high-performance liquid chromatography method is expected to be a powerful tool enabling the expansion of clinical usefulness and ensuring the elucidation of the roles of albumin in redox reactions throughout the human body.

  19. A clinically feasible method for the detection of potential collision in proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zou Wei; Lin Haibo; Plastaras, John P.; Wang Huanshu; Bui, Viet; Vapiwala, Neha; McDonough, James; Tochner, Zelig; Both, Stefan [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States) and Department of Mechanical Engineering, Drexel University, Philadelphia, Pennsylvania 19104 (United States); Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2012-11-15

    Purpose: Potential collision between the patient/couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, the treatment beam configuration, couch orientation, and the patient specific geometry. In this paper the authors developed an approach to detect possible patient-machine collisions using patient treatment plan data. Methods: The geometry of the machine and the patient was reconstructed relative to the isocenter of the proton treatment room. The surface contour of the gantry was first captured from the proton computer aided design and reconstructed to account for specific gantry rotation, snout position, collimator rotation, and range compensator dimensions based on the patient treatment plan data. The patient body and couch contours were captured from the patient's CT DICOM structure file. They were reconstructed relative to the isocenter taking into account treatment couch rotation. For potential collision that occurs at body portions where no CT images exist, scout images are used to construct the body contour. A software program was developed using a ray casting algorithm that was applied to detect collisions by determining if any of the patient and couch contour points fall into the spatial polygons formed by the proton gantry surfaces. Results: Twenty-four patient plans with or without potential collisions were retrospectively identified and analyzed using the collision detection software. In addition, five collision cases were artificially generated using an anthropomorphic phantom. The program successfully detected the collisions in all cases. The calculation time for each case was within 20 s. The software program was implemented in the authors' clinic to detect patient-gantry or gantry-couch collisions in the treatment planning

  20. Quantitative Clinical Imaging Methods for Monitoring Intratumoral Evolution.

    Science.gov (United States)

    Kim, Joo Yeun; Gatenby, Robert A

    2017-01-01

    images in landscape ecology and, with appropriate application of Darwinian first principles and sophisticated image analytic methods, can be used to estimate regional variations in the molecular properties of cancer cells.We have initially examined this technique in glioblastoma, a malignant brain neoplasm which is morphologically complex and notorious for a fast progression from diagnosis to recurrence and death, making a suitable subject of noninvasive, rapidly repeated assessment of intratumoral evolution. Quantitative imaging analysis of routine clinical MRIs from glioblastoma has identified macroscopic morphologic characteristics which correlate with proteogenomics and prognosis. The key to the accurate detection and forecasting of intratumoral evolution using quantitative imaging analysis is likely to be in the understanding of the synergistic interactions between observable intratumoral subregions and the resulting tumor behavior.