WorldWideScience

Sample records for echo-planar diffusion-weighted imaging

  1. Diffusion-weighted multiple shot echo planar imaging of humans without navigation.

    Science.gov (United States)

    Robson, M D; Anderson, A W; Gore, J C

    1997-07-01

    A new method is proposed for reducing the artifacts produced in diffusion-weighted imaging. When data are acquired using multiple shot echo planar acquisitions, conventional reconstruction methods produce artifactual images as a consequence of diffusion weighting and small amounts of bulk motion of the subject. If the amount of motion can be determined, it is possible to correct the data before reconstruction, which removes the artifact. A method for estimating the motion from the acquired data has been developed and evaluated. This method assumes that ghost image effects will be minimized when motion has been correctly compensated. By considering the amount of signal in the background of the image, appropriate corrections to the data can be made, and the accuracy of the motion compensation may be estimated. This technique has been evaluated by computer simulation, and its performance has been demonstrated in a phantom and humans with both two- and four-shot echo planar acquisitions and using both "mosaic" and "interleaved" sampling schemes.

  2. Echo Planar Diffusion-Weighted Imaging: Possibilities and Considerations with 12- and 32-Channel Head Coils

    Directory of Open Access Journals (Sweden)

    John N Morelli

    2012-01-01

    Full Text Available Interest in clinical brain magnetic resonance imaging using 32-channel head coils for signal reception continues to increase. The present investigation assesses possibilities for improving diffusion-weighted image quality using a 32-channel in comparison to a conventional 12-channel coil. The utility of single-shot (ss and an approach to readout-segmented (rs echo planar imaging (EPI are examined using both head coils. Substantial image quality improvements are found with rs-EPI. Imaging with a 32-channel head coil allows for implementation of greater parallel imaging acceleration factors or acquisition of scans at a higher resolution. Specifically, higher resolution imaging with rs-EPI can be achieved by increasing the number of readout segments without increasing echo-spacing or echo time to the degree necessary with ss-EPI - a factor resulting in increased susceptibility artifact and reduced signal-to-noise with the latter.

  3. Functional imaging of parotid glands: Diffusion-weighted echo-planar MRI before and after stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Habermann, C.R.; Cramer, M.C.; Gossrau, P.; Adam, G. [University Hospital Hamburg-Eppendorf (Germany). Department of Diagnostic and Interventional Radiology; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [University Hospital Hamburg-Eppendorf (Germany). Department of Oto-, Rhino-, Laryngology; Fiehler, J. [University Hospital Hamburg-Eppendorf (Germany). Department of Neuroradiology; Schoder, V. [University Hospital Hamburg-Eppendorf (Germany). Institute for Medical Biometry and Epidemiology

    2004-10-01

    Purpose: To investigate the feasibility of diffusion-weighted (DW) echo-planar imaging (EPI) for measuring different functional conditions of the parotid gland and to compare different measurement approaches. Materials and Methods: Parotid glands of 27 healthy volunteers were examined with a DW EPI sequence (TR 1,500 msec, TE 77 msec, field-of-view 250 x 250 mm, pixel size 2.10 x 1.95 mm, section thickness 5 mm) before and after oral stimulation with commercially available lemon juice. The b factors used were 0, 500, and 1,000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain) and evaluated with a manually placed circular region of interest (ROI) containing 100-200 pixel. Additional ROIs including the entire parotid gland were placed on either side. The results of both measurements were compared, using the Student's t test based on the median ADC values for each person. A two-tailed p-value of less than.05 was determined to indicate statistical significance. To compare both measurement approaches, the Pearson's correlation coefficient (r) was calculated. Results: Diffusion-weighted echo-planar MR imaging successfully visualized the parotid gland of all volunteers. In a first step, the median ADC value per person was computed. Using ROIs of 100-200 pixels, the mean was calculated to be 1.08 x 10{sup -3} mm{sup 2}/sec{+-}0.12 x 10{sup -3} mm{sup 2}/sec for both parotid glands prior to simulation. After stimulation, the mean ADC was measured at 1.15 x 10{sup -3} mm{sup 2}/sec{+-}0.11 x 10{sup -3} mm{sup 2}/sec for both parotid glands. Evaluating the entire parotid gland, the ADC was 1.12 x 10{sup -3} mm{sup 2}/sec{+-}0.08 x 10{sup -3} mm{sup 2}/sec prior to simulation, whereas the ADC increased to 1.18 x 10{sup -3} mm{sup 2}/sec{+-}0.09 x 10{sup -3} mm{sup 2}/sec after simulation with lemon juice. For both types of measurements, the increase in ADC after

  4. Implementation and assessment of diffusion-weighted partial Fourier readout-segmented echo-planar imaging.

    Science.gov (United States)

    Frost, Robert; Porter, David A; Miller, Karla L; Jezzard, Peter

    2012-08-01

    Single-shot echo-planar imaging has been used widely in diffusion magnetic resonance imaging due to the difficulties in correcting motion-induced phase corruption in multishot data. Readout-segmented EPI has addressed the multishot problem by introducing a two-dimensional nonlinear navigator correction with online reacquisition of uncorrectable data to enable acquisition of high-resolution diffusion data with reduced susceptibility artifact and T*(2) blurring. The primary shortcoming of readout-segmented EPI in its current form is its long acquisition time (longer than similar resolution single-shot echo-planar imaging protocols by approximately the number of readout segments), which limits the number of diffusion directions. By omitting readout segments at one side of k-space and using partial Fourier reconstruction, readout-segmented EPI imaging times could be reduced. In this study, the effects of homodyne and projection onto convex sets reconstructions on estimates of the fractional anisotropy, mean diffusivity, and diffusion orientation in fiber tracts and raw T(2)- and trace-weighted signal are compared, along with signal-to-noise ratio results. It is found that projections onto convex sets reconstruction with 3/5 segments in a 2 mm isotropic diffusion tensor image acquisition and 9/13 segments in a 0.9 × 0.9 × 4.0 mm(3) diffusion-weighted image acquisition provide good fidelity relative to the full k-space parameters. This allows application of readout-segmented EPI to tractography studies, and clinical stroke and oncology protocols. Copyright © 2011 Wiley-Liss, Inc.

  5. Diffusion-weighted echo planar imaging of acute brain infarction. A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Haruyuki; Ezuka, Isamu; Ikegami, Yoh; Suda, Tsuyoshi; Kakinuma, Kenichi; Kanazawa, Tsutomu; Higuchi, Shoichi [Niigata Rosai Hospital, Joetsu (Japan)

    1999-12-01

    The clinical usefulness of diffusion-weighted echo planar imaging (DW-EPI) was studied in 55 patients with acute brain ischemia. Ischemic lesions were identified on DW-EPI as hyperintense regions in all patients before changes were detected by conventional magnetic resonance imaging techniques in 12 cases studied earlier than 6 hours after onset. The earliest case was verified on DW-EPI at 50 minutes after onset. The ultra-fast imaging technique took less than 2 minutes to perform even for restless patients. Three patients had cardioembolic middle cerebral artery occlusion, and emergent percutaneous transluminal recanalization was carried out. Chronological changes in the signal of brain ischemia on DW-EPI depended on the site and size of the lesion, lacunar infarct of basal ganglia, and/or massive infarct due to major vessel occlusion, and were affected by associated hemorrhagic events. Coronal DW-EPI could more easily demarcate ischemia in the brainstem and/or cerebellum than axial scans when susceptibility artifacts were present. Coronal scans also demonstrated the site and direction of the pyramidal tract and its anatomical correlation with the lesions. DW-EPI has potential for the diagnostic and therapeutic planning of patients with acute brain ischemia. (author)

  6. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  7. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  8. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  9. A comparative quantitative analysis of magnetic susceptibility artifacts in echo planar and PROPELLER diffusion-weighted images

    Science.gov (United States)

    Cho, Jae-Hwan; Lee, Hae-Kag; Yang, Han-Joon; Lee, Gui-Won; Park, Yong-Soon; Chung, Woon-Kwan

    2013-01-01

    In this study, the authors investigated whether periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted imaging (DWI) can remove magnetic susceptibility artifacts and compared apparent diffusion coefficient (ADC) values for PROPELLER DWI and the common echo planar (EP) DWI. Twenty patients that underwent brain MRI with a metal dental implant were selected. A 3.0T MR scanner was then used to obtain EP DWI, PROPELLER DWI, and corresponding apparent diffusion coefficient (ADC) maps for a b-value of 0 and 1,000 s/mm2. The frequencies of magnetic susceptibility artifacts in four parts of the brain (bilateral temporal lobes, pons, and orbit) were selected. In the ADC maps, we measured the ADC values of both sides of the temporal lobe and the pons. According to the study results, the frequency of magnetic susceptibility artifacts in PROPELLER DW images was lower than it was in EP DW images. In ADC maps, the ADC values of the bilateral temporal lobes and the pons were all higher in PROPELLER ADC maps than in EP ADC maps. Our findings show that when a high-field MRI machine is used, magnetic susceptibility artifacts can distort anatomical structures and produce high-intensity signals. Furthermore, our findings suggest that in many cases, PROPELLER DWI would be helpful in terms of achieving a correct diagnosis.

  10. Clinical evaluation of echo-planar diffusion-weighted imaging (EPI-DWI) for diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Nakajima, Mika; Nitatori, Toshiaki; Matsuda, Minoru; Fukushima, Hisaki; Ihara, Kuniko; Seki, Tsuneaki

    2008-01-01

    The purpose of this study was to compare echo-planar diffusion-weighted imaging (EPI-DWI) with dynamic contrast-enhanced magnetic resonance imaging (MRI) in terms of the rate of detection, extension, and quality of diagnosis of breast cancer in order to estimate the usefulness of EPI-DWI. One hundred and three cases of 101 patients who underwent MRI prior to surgery for breast cancer were evaluated. (papillotubular carcinoma 22; solid-tubular carcinoma 20; scirrhous carcinoma 45; mucinous carcinoma 2; medullary carcinoma 1; invasive lobular carcinoma 2; apocrine carcinoma 2; ductal carcinoma in situ (DCIS) and microinvasive ductal carcinoma 9). Twelve cases of benign lesion were also evaluated. Single-shot EPI-DWI was performed before routine dynamic MRI and images of cancer detection and cancer extension both were compared with the pathological findings. The apparent diffusion coefficient (ADC) values of the lesions were measured and compared to the ADC values of benign lesions and normal breast tissues. The differences between the ADC values for the various histopathological types and the time-intensity curve (TIC) patterns of the dynamic MRI were also estimated. The EPI-DWI demonstrated abnormal high-intensity areas corresponding to the breast cancer lesions; these areas demonstrated good correlation with the enhanced areas observed in the early phase of dynamic MRI and cancer extension in the pathological findings. Frequently, normal breast tissues manifested as high-intensity areas in EPI-DWI; however, it was possible to distinguish between normal breast tissues and breast lesions by correlating these images with T2- weighted images and corresponding ADC values. The threshold value between malignant and benign lesions that resulted both high sensitivity and specificity was about 1.5 x 10 -3 x mm 2 /second. Mucinous carcinoma and DCIS/ microinvasive carcinoma exhibited higher ADC values than those observed in the other histopathological types, however, no

  11. On the signal-to-noise ratio efficiency and slab-banding artifacts in three-dimensional multislab diffusion-weighted echo-planar imaging.

    Science.gov (United States)

    Engström, Mathias; Mårtensson, Magnus; Avventi, Enrico; Skare, Stefan

    2015-02-01

    Three-dimensional (3D) multislab diffusion-weighted echo-planar imaging (EPI) has been suggested as an alternative for high-resolution diffusion-weighted imaging. In this work, the key components of the sequence are investigated, optimal scan parameter settings suggested, and a signal-to-noise ratio (SNR) analysis, comparing 2D diffusion-weighted EPI and 3D multislab diffusion-weighted EPI, is performed. Slab profiles were measured using 3D multislab EPI to investigate slab profile saturation effects with respect to TR, T1 and overlap between slabs. For short TR values, two methods to reduce the slab banding artifacts are proposed. Moreover, the SNR for 2D and 3D multislab (3D-MS) DWI have been simulated for various anatomical coverages and slab thicknesses. Simulated 3D multislab scans were shown to be more SNR-efficient than a corresponding 2D scan, for all investigated anatomical coverages and slab thicknesses. Slab banding artifacts being negligible for long repetition times (TRs) were strong for a TR of 2000 ms, proving that they stem from T1 -saturation effects. This banding was largely reduced by the suggested correction methods. In the low TR regime, T1 -saturation effects between adjacent slabs need to be taken in consideration to avoid slab-banding artifacts for multislab sequences. With the proposed correction methods the difference between the SNR-optimal TR and the TR where slab-banding artifacts become acceptable is reduced. © 2014 Wiley Periodicals, Inc.

  12. Functional imaging of submandibular glands: diffusion-weighted echo-planar MRI before and after stimulation; Diffusionsgewichtete MRT zur Funktionsdiagnostik der Glandula submandibularis

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, C.; Cramer, M.C.; Weiss, F.; Kaul, M.G.; Adam, G.; Habermann, C.R. [Zentrum fuer Bildgebende Diagnostik und Intervention, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Graessner, J. [Siemens Medical Solutions (Germany); Petersen, K. [Zentrum fuer Psychosoziale Medizin, Klinik und Poliklinik fuer Psychiatrie und Psychotherapie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Reitmeier, F.; Jaehne, M. [Kopf und Hautzentrum, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde, Universitaetsklinikum Hamburg Eppendorf (Germany)

    2006-09-15

    Purpose: To investigate the feasibility of diffusion-weighted (DWI) echo-planar imaging (EPI) to depict the submandibular glands and to measure different functional conditions. Materials and Methods: Twenty-seven healthy volunteers were examined. Diffusion weighted sequence was performed prior to stimulation. Exactly 30 seconds after a commercially available lemon juice was given orally, the diffusion weighted sequence was repeated. All examinations were performed by using a 1.5-T superconducting system with a 30 mT/m maximum gradient capability and maximum slew rate of 125 mT/m/sec (Magnetom Symphony, Siemens, Erlangen, Germany). The lower part of the circularly polarized (CP) head coil and a standard two-element CP neck array coil were used. The flexibility of the neck array coil allowed positioning the N1 element (upper part of the coil) right next to the submandibular gland. The axial diffusion-weighted EPI (echo planar imaging) sequence was performed using a matrix of 119 x 128, a field of view of 250 x 250 mm (pixel size 2.1 x 1.95 mm), a section thickness of 5 mm with an interslice gap of 1 mm. The b factors used were 0 sec/mm{sup 2}, 500 sec/mm{sup 2} and 1000 sec/mm{sup 2}. Apparent diffusion coefficient (ADC) maps were digitally transferred to MRIcro (Chris Rorden, University of Nottingham, Great Britain). After detecting the submandibular glands a region of interest (ROI) was placed manually exactly within the boarder of both submandibular glands, excluding the external carotid artery on ADC maps. These procedures were performed on all ADC slices the submandibular glands could be differentiated in before and after oral stimulation. For statistical comparison of results, a student's t-test was performed with an overall two-tailed significance level of p=0.05. Results: The visualization of the submandibular glands using the diffusion-weighted EPI sequence was possible in all of the 27 volunteers. Prior to oral stimulation an ADC of 1.31 x 10{sup -3

  13. Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Yiping, Lu [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Hui, Liu [MR Collaboration NE Asia, Siemens Healthcare, Siemens Ltd., China, Shanghai 201318 (China); Kun, Zhou [MR PLM APPL, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen 518057 (China); Daoying, Geng, E-mail: GengdaoyingGDY@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Bo, Yin, E-mail: yinbo7@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China)

    2014-07-15

    Purpose: The purpose of this study is to compare BLADE diffusion-weighted imaging (DWI) with single-shot echo planar imaging (EPI) DWI on the aspects of feasibility of imaging the sellar region and image quality. Methods: A total of 3 healthy volunteers and 52 patients with suspected lesions in the sellar region were included in this prospective intra-individual study. All exams were performed at 3.0 T with a BLADE DWI sequence and a standard single-shot EP-DWI sequence. Phantom measurements were performed to measure the objective signal-to-noise ratio (SNR). Two radiologists rated the image quality according to the visualisation of the internal carotid arteries, optic chiasm, pituitary stalk, pituitary gland and lesion, and the overall image quality. One radiologist measured lesion sizes for detecting their relationship with the image score. Results: The SNR in BLADE DWI sequence showed no significant difference from the single-shot EPI sequence (P > 0.05). All of the assessed regions received higher scores in BLADE DWI images than single-shot EP-DWI.

  14. Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Mikayama, Ryoji; Yabuuchi, Hidetake; Nagatomo, Kazuya; Kimura, Mitsuhiro; Kumazawa, Seiji [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan); Sonoda, Shinjiro; Kobayashi, Koji [Kyushu University Hospital, Division of Radiology, Department of Medical Technology, Fukuoka (Japan); Kawanami, Satoshi; Kamitani, Takeshi; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2018-01-15

    To compare image quality, apparent diffusion coefficient (ADC), and intravoxel incoherent motion (IVIM)-derived parameters between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the head and neck. Fourteen volunteers underwent head and neck imaging using TSE-DWI and EPI-DWI. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), ADC and IVIM-derived parameters were compared between the two techniques. Bland-Altman analysis was performed to analyse reproducibility between the quantitative parameters of TSE-DWI and EPI-DWI. DR of TSE-DWI was significantly smaller than that of EPI-DWI. SNR and CNR of TSE-DWI were significantly higher than those of EPI-DWI. ADC and IVIM-derived parameters of TSE-DWI showed higher values than those of EPI-DWI, although the difference was not significant. Bland-Altman analysis showed wide limits of agreement between the two sequences. TSE-DWI can produce better image quality than EPI-DWI, while TSE-DWI possibly exhibits different values of quantitative parameters. Therefore, TSE-DWI could be a good alternative to EPI-DWI for patients sensitive to distortion. However, it is not recommended to use both TSE-DWI and EPI-DWI on follow-up. (orig.)

  15. A characteristic feature of acute haematomas in the brain on echo-planar diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morita, N.; Yoneda, K.; Nishitani, H. [Department of Radiology, School of Medicine, University of Tokushima, 3-18-15, Kuramoto-Cho, Tokushima 770-8503 (Japan); Harada, M. [Department of Radiologic Technology, School of Health Sciences, University of Tokushima, 3-18-15, Kuramoto-Cho, Tokushima 770-8509 (Japan); Uno, M. [Department of Neurosurgery, School of Medicine, University of Tokushima, 3-18-15, Kuramoto-Cho, Tokushima 770-8503 (Japan)

    2002-11-01

    Diffusion-weighted MRI (DWI) is used in the diagnosis of acute ischaemic disease of the brain, but it is not clear whether or not it can be used to differentiate an acute haematoma from an infarct. Our purpose was to identify any characteristic feature of acute haematomas which can be recognised on DWI and to evaluate the usefulness of DWI in acute cerebral stroke. We examined nine patients with acute haemorrhage using CT and MRI including DWI. We measured the volume and apparent diffusion coefficient (ADC) of the haematomas. All showed heterogeneous signal on DWI, and the centre of the large (>20 ml) haematomas especially a mixed pattern with high and low signal. The characteristic feature of acute haematomas was a peripheral low-signal region, found in all subjects regardless of the size of the haematoma; acute infarcts did not show this. This low-signal rim on DWI may be useful for differentiating an acute haematoma from an infarct. (orig.)

  16. Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

    NARCIS (Netherlands)

    Coenegrachts, Kenneth; Matos, Celso; ter Beek, Léon; Metens, Thierry; Haspeslagh, Marc; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2009-01-01

    Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5 min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). Materials and

  17. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  18. Simultaneous multi-slice echo planar diffusion weighted imaging of the liver and the pancreas: Optimization of signal-to-noise ratio and acquisition time and application to intravoxel incoherent motion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boss, Andreas, E-mail: andreas.boss@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Barth, Borna; Filli, Lukas; Kenkel, David; Wurnig, Moritz C. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland); Piccirelli, Marco [Institute of Neuroradiology, University Hospital of Zurich (Switzerland); Reiner, Caecilia S. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (Switzerland)

    2016-11-15

    Purpose: To optimize and test a diffusion-weighted imaging (DWI) echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation in the liver and pancreas regarding acquisition time (TA), number of slices, signal-to-noise ratio (SNR), image quality (IQ), apparent diffusion coefficient (ADC) quantitation accuracy, and feasibility of intravoxel incoherent motion (IVIM) analysis. Materials and methods: Ten healthy volunteers underwent DWI of the upper abdomen at 3T. A SMS DWI sequence with CAIPIRINHA unaliasing technique (acceleration factors 2/3, denoted AF2/3) was compared to standard DWI-EPI (AF1). Four schemes were evaluated: (i) reducing TA, (ii) keeping TA identical with increasing number of averages, (iii) increasing number of slices with identical TA (iv) increasing number of b-values for IVIM. Acquisition schemes i-iii were evaluated qualitatively (reader score) and quantitatively (ADC values, SNR). Results: In scheme (i) no differences in SNR were observed (p = 0.321 − 0.038) with reduced TA (AF2 increase in SNR/time 75.6%, AF3 increase SNR/time 102.4%). No SNR improvement was obtained in scheme (ii). Increased SNR/time could be invested in acquisition of more and thinner slices or higher number of b-values. Image quality scores were stable for AF2 but decreased for AF3. Only for AF3, liver ADC values were systematically lower. Conclusion: SMS-DWI of the liver and pancreas provides substantially higher SNR/time, which either may be used for shorter scan time, higher slice resolution or IVIM measurements.

  19. Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2{sup *}-weighted and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, M. [Dept. of Radiology, Medizinische Universitaet zu Luebeck (Germany); Mayer, T.E.; Yousry, I.; Brueckmann, H. [Dept. of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany); Hamann, G.F. [Dept. of Neurology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany)

    2001-05-01

    We investigated the usefulness of echo-planar imaging (EPI) as well as T2{sup *}-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2{sup *}-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. (orig.)

  20. Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image (T{sub 2} and FLAIR) Sequence

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong Kap [Dept. of Radiology, Cheomdan Medical Center, Gwangju (Korea, Republic of); Im, Jung Yeol [Dept. of Digital Management Information Graduate School of Nambu Univesity, Gwangju (Korea, Republic of)

    2009-09-15

    Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in T{sub 2}-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  1. High-resolution three-dimensional diffusion-weighted imaging of middle ear cholesteatoma at 3.0 T MRI: Usefulness of 3D turbo field-echo with diffusion-sensitized driven-equilibrium preparation (TFE–DSDE) compared to single-shot echo-planar imaging

    International Nuclear Information System (INIS)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Obara, Makoto; Togao, Osamu; Matsumoto, Nozomu; Kikuchi, Kazufumi; Honda, Hiroshi

    2013-01-01

    Objective: To prospectively evaluate the usefulness of a newly developed high-resolution three-dimensional diffusion-weighted imaging method, turbo field-echo with diffusion-sensitized driven-equilibrium (TFE–DSDE) in diagnosing middle-ear cholesteatoma by comparing it to conventional single-shot echo-planar diffusion-weighted imaging (SS-EP DWI). Materials and methods: Institutional review board approval and informed consent from all participants were obtained. We studied 30 patients with preoperatively suspected acquired cholesteatoma. Each patient underwent an MR examination including both SS-EP DWI and DSDE-TFE using a 3.0 T MR scanner. Images of the 30 patients (60 temporal bones including 30 with and 30 without cholesteatoma) were reviewed by two independent neuroradiologists. The confidence level for the presence of cholesteatoma was graded on a scale of 0–2 (0 = definite absence, 1 = equivocal, 2 = definite presence). Interobserver agreement as well as sensitivity, specificity, and accuracy for detection were assessed for the two reviewers. Results: Excellent interobserver agreement was shown for TFE–DSDE (κ = 0.821) whereas fair agreement was obtained for SS-EP DWI (κ = 0.416). TFE–DSDE was associated with significantly higher sensitivity (83.3%) and accuracy (90.0%) compared to SS-EP DWI (sensitivity = 35.0%, accuracy = 66.7%; p < 0.05). No significant difference was found in specificity (96.7% for TFE–DSDE, 98.3% for SS-EP DWI) Conclusion: With increased spatial resolution and reduced susceptibility artifacts, TFE–DSDE improves the accuracy in diagnosing acquired middle ear cholesteatomas compared to SS-EP DWI

  2. MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Huwart, Laurent; Salameh, Najat; Peeters, Frank; Beers, Bernard E. van [Universite Catholique de Louvain, St-Luc University Hospital, Diagnostic Radiology Unit, Brussels (Belgium); Beek, Leon ter [Philips Medical Systems, Best (Netherlands); Vicaut, Eric [Universite Paris Diderot, Hopital Lariboisiere, Paris (France); Sinkus, Ralph [Universite Paris Diderot, Laboratoire Ondes et Acoustique, Ecole Superieure de Physique et de Chimie Industrielles de la Ville de Paris, Paris (France)

    2008-11-15

    The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 {+-} 5.37 for spin-echo versus 21.02 {+-} 4.76 for echo-planar, p = 0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r = 0.91 (p < 0.01) with spin-echo and r = 0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p = 0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r = 0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice. (orig.)

  3. Initial experience in perfusion MR imaging of intracranial major artery occlusion with echo-planar technique

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Mizutani, Yoshiyuki; Inaoka, Sayuki; Hachiya, Junichi

    1997-01-01

    The purpose of this study was to evaluate the usefulness of perfusion MR imaging using a single-shot echo-planar technique in occlusion of intracranial main arteries. Our patient group consisted of 16 patients with internal carotid artery occlusion (n=9), Moyamoya disease (n=4), and middle cerebral artery occlusion (n=3). We performed the echo-planar perfusion studies with a 1.5-T unit using a free-induction-decay-type echo-planar sequence. With a bolus injection of Gd-DTPA, 30 consecutive scans were obtained at 10 sections every 2 seconds. The data were analyzed in three ways: a time-intensity curves in the territory of the involved artery (n=16); semiquantitative flow map of each section representing signal changes due to passage of Gd-DTPA (n=15); and serial images at a selected section (n=7). The time intensity curves were abnormal in 13 patients. The peak of signal drop was delayed in all of them. Flow maps showed focal flow abnormalities in 11 patients, but they were apparently normal in 4 patients probably due to collateral flow. In serial images, delay in appearance and/or disappearance of Gd-DTPA was noted in 6 patients. In patients with occlusion of intracranial main arteries, MR single-shot echo-planar technique is of clinical use because it can provide information about hemodynamic changes in a short examination time, in multiple sections, and with good temporal resolution. (author)

  4. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  5. Breath-hold MR cholangiopancreatography with three-dimensional, segmented, echo-planar imaging and volume rendering

    NARCIS (Netherlands)

    P.A. Wielopolski (Piotr); J. Gaa; D.R. Wielopolski; M. Oudkerk (Matthijs)

    1999-01-01

    textabstractEnd-expiration, 21-second breath-hold, three-dimensional magnetic resonance (MR) cholangiopancreatography (MRCP) was developed with segmented echo-planar imaging. In 15 healthy subjects and 14 randomly selected patients undergoing liver studies,

  6. Echo planar imaging of normal and abnormal connections of the heart and great arteries

    Energy Technology Data Exchange (ETDEWEB)

    Chrispin, A.; Small, P.; Rutter, N.; Coupland, R.E.; Doyle, M.; Chapman, B.; Coxon, R.; Guilfoyle, D.; Cawley, M.; Mansfield, P.

    1986-05-01

    Echo planar imaging (EPI) is that form of magnetic resonance imaging which provides very short image acquisition times. EPI also provides very rapid sequential imaging. The EPI method is ideal for imaging the heart and thoracic content because images are devoid of cardio-respiratory motion artefact. Previously an analysis of transectional images has been presented. This paper is concerned with the study of the heart by the use of EPI contsructions in the sagittal and coronal planes. Defining connections between ventricle and great artery is of cardinal importance in paediatric cardiology. EPI contsructions in the normal heart, transposition, truncus arteriosus and right heart hypoplasia are presented and discussed.

  7. Echo planar imaging of normal and abnormal connections of the heart and great arteries

    International Nuclear Information System (INIS)

    Chrispin, A.; Small, P.; Rutter, N.; Coupland, R.E.; Doyle, M.; Chapman, B.; Coxon, R.; Guilfoyle, D.; Cawley, M.; Mansfield, P.

    1986-01-01

    Echo planar imaging (EPI) is that form of magnetic resonance imaging which provides very short image acquisition times. EPI also provides very rapid sequential imaging. The EPI method is ideal for imaging the heart and thoracic content because images are devoid of cardio-respiratory motion artefact. Previously an analysis of transectional images has been presented. This paper is concerned with the study of the heart by the use of EPI contsructions in the sagittal and coronal planes. Defining connections between ventricle and great artery is of cardinal importance in paediatric cardiology. EPI contsructions in the normal heart, transposition, truncus arteriosus and right heart hypoplasia are presented and discussed. (orig.)

  8. Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Wech, Tobias; Neubauer, Henning; Veldhoen, Simon; Bley, Thorsten Alexander; Koestler, Herbert [Wuerzburg Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2017-10-01

    Echo Planar Imaging (EPI) is most commonly applied to acquire diffusion-weighted MR-images. EPI is able to capture an entire image in very short time, but is prone to distortions and artifacts. In diffusion-weighted EPI of the kidney severe distortions may occur due to intestinal gas. Turbo Spin Echo (TSE) is robust against distortions and artifacts, but needs more time to acquire an entire image compared to EPI. Therefore, TSE is more sensitive to motion during the readout. In this study we compare diffusion-weighted TSE and EPI of the human kidney with regard to intravoxel incoherent motion (IVIM) and diffusion tensor imaging (DTI). Images were acquired with b-values between 0 and 750 s/mm{sup 2} with TSE and EPI. Distortions were observed with the EPI readout in all volunteers, while the TSE images were virtually distortion-free. Fractional anisotropy of the diffusion tensor was significantly lower for TSE than for EPI. All other parameters of DTI and IVIM were comparable for TSE and EPI. Especially the main diffusion directions yielded by TSE and EPI were similar. The results demonstrate that TSE is a worthwhile distortion-free alternative to EPI for diffusion-weighted imaging of the kidney at 3 Tesla.

  9. Sjoegren's syndrome of the parotid gland: value of diffusion-weighted echo-planar MRI for diagnosis at an early stage based on MR sialography grading in comparison with healthy volunteers

    International Nuclear Information System (INIS)

    Regier, Marc; Ries, T.; Arndt, C.; Cramer, M.C.; Adam, G.; Habermann, C.R.; Graessner, J.; Reitmeier, F.; Jaehne, M.

    2009-01-01

    To investigate the value of diffusion-weighted echo-planar imaging (DW-EPI) for quantifying functional changes of the parotid gland in Sjoegren's disease and to evaluate whether ADC mapping allows for early diagnosis based on MR sialography grading. Using a DW-EPI sequence at 1.5T (b-factors: 0, 500 and 1000 sec/mm 2 ), the parotid glands of 52 healthy volunteers and 13 patients with histologically verified affection of Sjoegren's disease were examined. All scans were performed prior to and following gustatory stimulation with 5 ml of lemon juice. ADC maps were evaluated by placing an inordinate region-of-interest (ROI) enclosing the entire parotid gland. Sjoegren's disease was graded based on MR sialography findings using a 4-point grading-scale. Statistics included student t-test and kappa-analysis. In healthy volunteers mean ADCs of 1.14 x 10 -3 mm 2 /sec before and 1.2 x 10 -3 mm 2 /sec after stimulation were observed. Higher ADCs were determined for early-stage Sjoegren's disease, averaging 1.22 x 10 -3 mm 2 /sec before and 1.29 x 10 -3 mm 2 /sec after stimulation. Advanced disease revealed significantly lower ADCs (0.97 x 10 -3 mm 2 /sec (p = 0.002) before and 1.01 x 10 -3 mm 2 /sec (p < 0.001) after stimulation). (orig.)

  10. Comparison of Fourier transform and continuous wavelet transform to study echo-planar imaging flow maps

    International Nuclear Information System (INIS)

    Rodriguez G, A.; Bowtell, R.; Mansfield, P.

    1998-01-01

    Velocity maps were studied combining Doyle and Mansfield method (1986) with each of the following transforms: Fourier, window Fourier and wavelet (Mexican hat). Continuous wavelet transform was compared against the two Fourier transform to determine which technique is best suited to study blood maps generated by Half Fourier Echo-Planar Imaging. Coefficient images were calculated and plots of the pixel intensity variation are presented. Finally, contour maps are shown to visualize the behavior of the blood flow in the cardiac chambers for the wavelet technique. (Author)

  11. Comparison of Fourier transform and continuous wavelet transform to study echo-planar imaging flow maps

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez G, A.; Bowtell, R.; Mansfield, P. [Area de Procesamiento Digital de Senales e Imagenes Biomedicas. Universidad Autonoma Metropolitana Iztapalapa. Mexico D.F. 09340 Mexico (Mexico)

    1998-12-31

    Velocity maps were studied combining Doyle and Mansfield method (1986) with each of the following transforms: Fourier, window Fourier and wavelet (Mexican hat). Continuous wavelet transform was compared against the two Fourier transform to determine which technique is best suited to study blood maps generated by Half Fourier Echo-Planar Imaging. Coefficient images were calculated and plots of the pixel intensity variation are presented. Finally, contour maps are shown to visualize the behavior of the blood flow in the cardiac chambers for the wavelet technique. (Author)

  12. Whole-brain analysis of amyotrophic lateral sclerosis by using echo-planar spectroscopic imaging.

    Science.gov (United States)

    Verma, Gaurav; Woo, John H; Chawla, Sanjeev; Wang, Sumei; Sheriff, Sulaiman; Elman, Lauren B; McCluskey, Leo F; Grossman, Murray; Melhem, Elias R; Maudsley, Andrew A; Poptani, Harish

    2013-06-01

    To detect regional metabolic differences in amyotrophic lateral sclerosis (ALS) with whole-brain echo-planar spectroscopic imaging. Sixteen patients with ALS (nine men, seven women; mean age, 56.6 years), five persons suspected of having ALS (four men, one woman; mean age, 62.6 years), and 10 healthy control subjects (five men, five women; mean age, 56.1 years) underwent echo-planar spectroscopic imaging after providing informed consent. The study was approved by the institutional review board and complied with HIPAA. Data were analyzed with the Metabolic Imaging and Data Analysis System software, and processed metabolite maps were coregistered and normalized to a standard brain template. Metabolite maps of creatine (Cr), choline (Cho), and N-acetylaspartate (NAA) were segmented into 81 regions with Automated Anatomical Labeling software to measure metabolic changes throughout the brains of patients with ALS. Statistical analysis involved an unpaired, uncorrected, two-sided Student t test. The NAA/Cho ratio across six regions was significantly lower by a mean of 23% (P ≤ .01) in patients with ALS than in control subjects. These regions included the caudate, lingual gyrus, supramarginal gyrus, and right and left superior and right inferior occipital lobes. The NAA/Cr ratio was significantly lower (P ≤ .01) in eight regions in the patient group, by a mean of 16%. These included the caudate, cuneus, frontal inferior operculum, Heschl gyrus, precentral gyrus, rolandic operculum, and superior and inferior occipital lobes. The Cho/Cr ratio did not significantly differ in any region between patient and control groups. Whole-brain echo-planar spectroscopic imaging permits detection of regional metabolic abnormalities in ALS, including not only the motor cortex but also several other regions implicated in ALS pathophysiologic findings.

  13. Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2013-01-01

    Echo planar imaging (EPI) is most commonly used for blood oxygen level-dependent fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed "interleaved dual echo with acceleration (IDEA) EPI": two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase encoding blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 T and 7 T. Copyright © 2012 Wiley Periodicals, Inc.

  14. Block-Matching Distortion Correction of Echo-Planar Images With Opposite Phase Encoding Directions.

    Science.gov (United States)

    Hedouin, Renaud; Commowick, Olivier; Bannier, Elise; Scherrer, Benoit; Taquet, Maxime; Warfield, Simon K; Barillot, Christian

    2017-05-01

    By shortening the acquisition time of MRI, Echo Planar Imaging (EPI) enables the acquisition of a large number of images in a short time, compatible with clinical constraints as required for diffusion or functional MRI. However such images are subject to large, local distortions disrupting their correspondence with the underlying anatomy. The correction of those distortions is an open problem, especially in regions where large deformations occur. We propose a new block-matching registration method to perform EPI distortion correction based on the acquisition of two EPI with opposite phase encoding directions (PED). It relies on new transformations between blocks adapted to the EPI distortion model, and on an adapted optimization scheme to ensure an opposite symmetric transformation. We present qualitative and quantitative results of the block-matching correction using different metrics on a phantom dataset and on in-vivo data. We show the ability of the block-matching to robustly correct EPI distortion even in strongly affected areas.

  15. Sjoegren's syndrome of the parotid gland: value of diffusion-weighted echo-planar MRI for diagnosis at an early stage based on MR sialography grading in comparison with healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Regier, Marc; Ries, T.; Arndt, C.; Cramer, M.C.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Graessner, J. [Siemens AG, Hamburg (Germany). Medical Solutions; Reitmeier, F.; Jaehne, M. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde

    2009-03-15

    To investigate the value of diffusion-weighted echo-planar imaging (DW-EPI) for quantifying functional changes of the parotid gland in Sjoegren's disease and to evaluate whether ADC mapping allows for early diagnosis based on MR sialography grading. Using a DW-EPI sequence at 1.5T (b-factors: 0, 500 and 1000 sec/mm{sup 2}), the parotid glands of 52 healthy volunteers and 13 patients with histologically verified affection of Sjoegren's disease were examined. All scans were performed prior to and following gustatory stimulation with 5 ml of lemon juice. ADC maps were evaluated by placing an inordinate region-of-interest (ROI) enclosing the entire parotid gland. Sjoegren's disease was graded based on MR sialography findings using a 4-point grading-scale. Statistics included student t-test and kappa-analysis. In healthy volunteers mean ADCs of 1.14 x 10{sup -3} mm{sup 2} /sec before and 1.2 x 10{sup -3} mm{sup 2} /sec after stimulation were observed. Higher ADCs were determined for early-stage Sjoegren's disease, averaging 1.22 x 10{sup -3} mm{sup 2} /sec before and 1.29 x 10{sup -3} mm{sup 2} /sec after stimulation. Advanced disease revealed significantly lower ADCs (0.97 x 10{sup -3} mm{sup 2} /sec (p = 0.002) before and 1.01 x 10{sup -3} mm{sup 2} /sec (p < 0.001) after stimulation). (orig.)

  16. Selective visualization of pelvic splanchnic nerve and pelvic plexus using readout-segmented echo-planar diffusion-weighted magnetic resonance neurography: A preliminary study in healthy male volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Rikiya, E-mail: rickdom@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Isoda, Hiroyoshi, E-mail: sayuki@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Arizono, Shigeki, E-mail: arizono@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Furuta, Akihiro, E-mail: akihirof@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Tsuyoshi, E-mail: goohno@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging, Osaka Red Cross Hospital, 5-30 Fudegasaki-cho, Tennoji-ku, Osaka, 543-8555 (Japan); Ono, Ayako, E-mail: onoayako@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Murata, Katsutoshi, E-mail: katsutoshi.murata@siemens.com [Siemens Healthcare Japan KK, Gate City Osaki West Tower, 11-1 Osaki 1-Chome, Shinagawa-ku, Tokyo 141-8644 (Japan); Togashi, Kaori, E-mail: ktogashi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan)

    2017-01-15

    Highlights: • RS-EPI DW-MRN has a potential to selectively depict the pelvic parasympathetic nerve. • The nervous visibility showed a moderate correlation with the image artifact level. • Our method could help preserving function after pelvic nerve-preserving surgery. - Abstract: Purpose: To evaluate the potential of readout-segmented echo-planar diffusion-weighted magnetic resonance neurography (RS-EPI DW-MRN) for the selective visualization of pelvic splanchnic nerve and pelvic plexus in healthy male volunteers. Materials and methods: Institutional review board approval and written informed consent were obtained. RS-EPI DW-MRN images were acquired from thirteen healthy male volunteers aged 25–48 years between September 2013 and December 2013. For RS-EPI DW-MRN, the following parameters were used: spatial resolution, 1.1 × 1.1 × 2.5 mm; b-value, 250 s/mm{sup 2}; number of readout-segments, seven; and acquisition time, 7 min 45 s. For qualitative assessment, two abdominal radiologists independently evaluated the visibility of the pelvic splanchnic nerves and pelvic plexuses bilaterally in each subject on oblique coronal thin-slab 10-mm-thick maximum intensity projection images and scored it with a 4-point grading scale (excellent, good, fair, poor). Both readers scored twice at 6-month intervals. Inter-observer and intra-observer variability were evaluated using Cohen’s quadratically weighted κ statistics. Image artifact level was scored on a 4-point grading scale by other two abdominal radiologists in order to evaluate the correlation between the nerve visibility and the severity of imaging artifacts using the Spearman’s correlation coefficient. Results: Qualitative grading showed the following success rate (number of nerves qualitatively scored as excellent or good divided by total number of nerves): reader 1 (first set), 73% (19/26); reader 2 (first set), 77% (20/26); reader 1 (second set), 81% (21/26); and reader 2 (second set), 77% (20

  17. Diffusion-weighted MR imaging (DWI) in spinal cord ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, Majda M. [Medical University of Vienna, Department of Radiology, Neuroradiology Section, Vienna (Austria); Bammer, Roland [Stanford University, Lucas MRS/I Center, Department of Radiology, Stanford, CA (United States)

    2006-11-15

    Spinal cord infarction is a rare clinical diagnosis characterized by a sudden onset of paralysis, bowel and bladder dysfunction, and loss of pain and temperature perception, with preservation of proprioception and vibration sense. Magnetic resonance imaging (MRI) usually demonstrates intramedullary hyperintensity on T2-weighted MR images with cord enlargement. However, in approximately 45% of patients, MR shows no abnormality. Diffusion-weighted MR imaging (DWI) has been widely used for the evaluation of a variety of brain disorders, especially for acute stroke. Preliminary data suggest that DWI has the potential to be useful in the early detection of spinal infarction. We performed DWI, using navigated, interleaved, multishot echo planar imaging (IEPI), in a series of six patients with a clinical suspicion of acute spinal cord ischemia. In all patients, high signal was observed on isotropic DWI images with low ADC values (0.23 and 0.86 x 10{sup -3} cm{sup 2}/s), indicative of restricted diffusion. We analyzed the imaging findings from conventional MR sequences and diffusion-weighted MR sequences in six patients with spinal cord infarction, compared the findings with those in published series, and discuss the value of DWI in spinal cord ischemia based on current experience. Although the number of patients with described DWI findings totals only 23, the results of previously published studies and those of our study suggest that DWI has the potential to be a useful and feasible technique for the detection of spinal infarction. (orig.)

  18. Diffusion-weighted MR imaging (DWI) in spinal cord ischemia

    International Nuclear Information System (INIS)

    Thurnher, Majda M.; Bammer, Roland

    2006-01-01

    Spinal cord infarction is a rare clinical diagnosis characterized by a sudden onset of paralysis, bowel and bladder dysfunction, and loss of pain and temperature perception, with preservation of proprioception and vibration sense. Magnetic resonance imaging (MRI) usually demonstrates intramedullary hyperintensity on T2-weighted MR images with cord enlargement. However, in approximately 45% of patients, MR shows no abnormality. Diffusion-weighted MR imaging (DWI) has been widely used for the evaluation of a variety of brain disorders, especially for acute stroke. Preliminary data suggest that DWI has the potential to be useful in the early detection of spinal infarction. We performed DWI, using navigated, interleaved, multishot echo planar imaging (IEPI), in a series of six patients with a clinical suspicion of acute spinal cord ischemia. In all patients, high signal was observed on isotropic DWI images with low ADC values (0.23 and 0.86 x 10 -3 cm 2 /s), indicative of restricted diffusion. We analyzed the imaging findings from conventional MR sequences and diffusion-weighted MR sequences in six patients with spinal cord infarction, compared the findings with those in published series, and discuss the value of DWI in spinal cord ischemia based on current experience. Although the number of patients with described DWI findings totals only 23, the results of previously published studies and those of our study suggest that DWI has the potential to be a useful and feasible technique for the detection of spinal infarction. (orig.)

  19. Anatomical constraints on visualization of the human hippocampus using echo-planar imaging

    International Nuclear Information System (INIS)

    Asano, Shuichiro; Kirino, Takaaki; Mihara, Ban; Sugishita, Morihiro

    2004-01-01

    Reliable visualization of the hippocampus on echo-planar imaging (EPI) is essential in analyzing memory function using functional magnetic resonance imaging. However, the hippocampal area is notoriously prone to susceptibility artifacts caused by structures at the skull base, and avoiding such artifacts by appropriately selecting the subjects for a study is of practical importance. To elucidate factors affecting the extent of the artifacts we obtained EPI in a total of 62 hippocampi from 31 healthy volunteers and evaluated various anatomical measurements possibly associated with the quality of the images. The hippocampal head was sufficiently well demonstrated on 40 of 62 images (65%), and there were two parameters that significantly differed between the good (n=40) and poor (n=22) imaging studies: The vertical diameter (DV) of the opening of the internal acoustic meatus (IAM) and the pneumatization rate of the sphenoid sinus (RP-SS). From logistic regression analysis with the stepwise method, in addition to these two factors, the distance between the hippocampal body and IAM (Dhippo-IAM) and the distance between the hippocampal head and the middle cranial fossa at the skull base (Dhippo-base) were extracted. DV-IAM, RP-SS, and Dhippo-base were negatively correlated with the good imaging of the hippocampal head. On the other hand, Dhippo-IAM was positively correlated. These easily measurable parameters will be helpful in selecting subjects and in increasing the efficiency of hippocampal visualization in studies on human memory function. (orig.)

  20. Study of internal structure of the human fetus in utero by echo-planar magnetic resonance imaging.

    Science.gov (United States)

    Johnson, I R; Stehling, M K; Blamire, A M; Coxon, R J; Howseman, A M; Chapman, B; Ordidge, R J; Mansfield, P; Symonds, E M; Worthington, B S

    1990-08-01

    The ultrafast echo-planar magnetic resonance imaging technology, developed and built in Nottingham, has been used to produce the first snapshot images of the human fetus in utero. The imager, operating at a proton resonance frequency of 22 MHz, produces transaxial views in 64 or 128 milliseconds. These images comprise either 64 x 128 or 128 x 128 pixels with an in-plane resolution of 3 x 3 mm2. The slice thickness is 10 mm. Fetal scans of up to 32 contiguous slices are produced in a few minutes. These have been used to study the internal structure of the uterus and the fetus in a range of cases with gestations ranging from 26 weeks to term. Echo-planar imaging seems particularly suitable as an imaging modality since its high speed obviates image blurring arising from fetal motion.

  1. Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions.

    Science.gov (United States)

    Chauhan, Munish; Vidya Shankar, Rohini; Ashok Kumar, Neeta; Kodibagkar, Vikram D; Sadleir, Rosalind

    2018-01-01

    Magnetic resonance electrical impedance tomography (MREIT) sequences typically use conventional spin or gradient echo-based acquisition methods for reconstruction of conductivity and current density maps. Use of MREIT in functional and electroporation studies requires higher temporal resolution and faster sequences. Here, single and multishot echo planar imaging (EPI) based MREIT sequences were evaluated to see whether high-quality MREIT phase data could be obtained for rapid reconstruction of current density, conductivity, and electric fields. A gel phantom with an insulating inclusion was used as a test object. Ghost artifact, geometric distortion, and MREIT correction algorithms were applied to the data. The EPI-MREIT-derived phase-projected current density and conductivity images were compared with simulations and spin-echo images as a function of EPI shot number. Good agreement among measures in simulated, spin echo, and EPI data was achieved. Current density errors were stable and below 9% as the shot number decreased from 64 to 2, but increased for single-shot images. Conductivity reconstruction relative contrast ratios were stable as the shot number decreased. The derived electric fields also agreed with the simulated data. The EPI methods can be combined successfully with MREIT reconstruction algorithms to achieve fast imaging of current density, conductivity, and electric field. Magn Reson Med 79:71-82, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. Three-dimensional echo-planar cine imaging of cerebral blood supply using arterial spin labeling.

    Science.gov (United States)

    Shrestha, Manoj; Mildner, Toralf; Schlumm, Torsten; Robertson, Scott Haile; Möller, Harald

    2016-12-01

    Echo-planar imaging (EPI) with CYlindrical Center-out spatiaL Encoding (EPICYCLE) is introduced as a novel hybrid three-dimensional (3D) EPI technique. Its suitability for the tracking of a short bolus created by pseudo-continuous arterial spin labeling (pCASL) through the cerebral vasculature is demonstrated. EPICYCLE acquires two-dimensional planes of k-space along center-out trajectories. These "spokes" are rotated from shot to shot about a common axis to encode a k-space cylinder. To track a bolus of labeled blood, the same subset of evenly distributed spokes is acquired in a cine fashion after a short period of pCASL. This process is repeated for all subsets to fill the whole 3D k-space of each time frame. The passage of short pCASL boluses through the vasculature of a 3D imaging slab was successfully imaged using EPICYCLE. By choosing suitable sequence parameters, the impact of slab excitation on the bolus shape could be minimized. Parametric maps of signal amplitude, transit time, and bolus width reflected typical features of blood transport in large vessels. The EPICYCLE technique was successfully applied to track a short bolus of labeled arterial blood during its passage through the cerebral vasculature.

  3. In Vivo 31P Echo-Planar Spectroscopic Imaging of Human Calf Muscle

    Science.gov (United States)

    Wilhelm, Thomas; Bachert, Peter

    2001-03-01

    Localized phosphorus-31 NMR spectra of human calf muscle in vivo were obtained by means of echo-planar spectroscopic imaging (EPSI) with a 1.5-T whole-body scanner. The technique permits the measurement of two-dimensional 31P SI data at a minimum acquisition time of 2.4 s (8×8 voxels, TR=300 ms). With 9.4 min measurement time (TR=1100 ms, 64 averages) and 25×25×40 mm spatial resolution in vivo the 31P NMR signal-to-noise ratio (S/N) of the phosphocreatine (PCr) resonance was about 45; the multiplets of nucleoside 5‧-triphosphates were resolved. Spectral quality permits quantitative assessment of the PCr signal in a measurement time that is shorter by a factor of 2 or more than the minimum measurement time feasible with chemical-shift imaging. In a functional EPSI study with a time resolution of 20.5 s on the calf muscle of volunteers, spectra showed a 40% decrease of the PCr signal intensity (at rest: S/N≅12) upon exertion of the muscle.

  4. Measurement of T1 by echo-planar imaging and the construction of computer-generated images

    International Nuclear Information System (INIS)

    Mansfield, P.; Guilfoyle, D.N.; Ordidge, R.J.; Coupland, R.E.

    1986-01-01

    The high-speed echo-planar imaging (EPI) technique is used to obtain rapid T 1 and spin density measurements by a two-point method. It is shown that neglect of edge effects in the slice selection procedure leads to significant systematic errors in T 1 . T 1 maps for two young patients, obtained at 4.0 MHz, are presented. The T 1 and spin density values obtained are used to produce computer-generated images in inversion recovery simulations. These results demonstrate marked improvement in image contrast without paying the time penalty incurred in real experiments, thereby greatly increasing patient throughput potential. (author)

  5. Echo planar perfusion imaging with high spatial and temporal resolution: methodology and clinical aspects

    International Nuclear Information System (INIS)

    Bitzer, M.; Klose, U.; Naegele, T.; Friese, S.; Kuntz, R.; Voigt, K.; Fetter, M.; Opitz, H.

    1999-01-01

    The purpose of the present study was to analyse specific advantages of calculated parameter images and their limitations using an optimized echo-planar imaging (EPI) technique with high spatial and temporal resolution. Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) was performed in 12 patients with cerebrovascular disease and in 13 patients with brain tumours. For MR imaging of cerebral perfusion an EPI sequence was developed which provides a temporal resolution of 0.68 s for three slices with a 128 x 128 image matrix. To evaluate DSC-MRI, the following parameter images were calculated pixelwise: (1) Maximum signal reduction (MSR); (2) maximum signal difference (ΔSR); (3) time-to-peak (T p ); and (4) integral of signal-intensity-time curve until T p (S Int ). The MSR maps were superior in the detection of acute infarctions and ΔSR maps in the delineation of vasogenic brain oedema. The time-to-peak (T p ) maps seemed to be highly sensitive in the detection of poststenotic malperfused brain areas (sensitivity 90 %). Hyperperfused areas of brain tumours were detectable down to a diameter of 1 cm with high sensitivity (> 90 %). Distinct clinical and neuroradiological conditions revealed different suitabilities for the parameter images. The time-to-peak (T p ) maps may be an important advantage in the detection of poststenotic ''areas at risk'', due to an improved temporal resolution using an EPI technique. With regard to spatial resolution, a matrix size of 128 x 128 is sufficient for all clinical conditions. According to our results, a further increase in matrix size would not improve the spatial resolution in DSC-MRI, since the degree of the vascularization of lesions and the susceptibility effect itself seem to be the limiting factors. (orig.)

  6. Diffusion-weighted MR imaging of the abdomen with pulse triggering

    International Nuclear Information System (INIS)

    Muertz, P.; Pauleit, D.; Traeber, F.; Kreft, B.P.; Schild, H.H.

    2000-01-01

    Purpose: The aim of this work was to reduce the influence of motion on diffusion-weighted MR images of the abdomen by pulse triggering of single-shot sequences. Methods: Five healthy volunteers were examined both without and with finger pulse-triggering of a diffusion-weighted single-shot echo planar MR imaging sequence at 1.5 T. Series of diffusion-weighted images were acquired at different phases of the cardiac cycle by varying the time delay between finger pulse and sequence acquisition. The measurements were repeated three times. The diffusion weighted images were analysed by measuring the signal intensities and by determining the ADC values within the spleen, kidney and liver. Results: The magnitude of motion artifacts on diffusion weighted images shows a strong dependence on the trigger delay. The optimum trigger delay is found to be between 500 and 600 ms. For these values the abdominal organs appear homogeneous on all diffusion weighted images and the strongest signal intensities are detected. At optimum triggering the accuracy of the apparent diffusion coefficients is up to 10 times better than without triggering. Moreover, the standard deviation of the repeated measurements is smaller than 12% for all volunteers and for all organs. Without triggering the standard deviation is larger by a factor of 4 on average. Conclusion: Pulse triggering of single-shot sequences leads to significant reduction of motion related artifacts on diffusion weighted images of the abdomen and provides more accurate and reproducible ADC values. (orig.) [de

  7. Feasibility and reproducibility of echo planar spectroscopic imaging on the quantification of hepatic fat.

    Directory of Open Access Journals (Sweden)

    Yi-Ru Lin

    Full Text Available 1H-MRS is widely regarded as the most accurate noninvasive method to quantify hepatic fat content (HFC. When practical period of breath holding, and acquisition of HFC over multiple liver areas is considered, a fast MR spectroscopic imaging technique is desired. The aim of this study is to examine the feasibility and reproducibility of echo planar spectroscopic imaging (EPSI on the quantification of HFC in subject with various HFCs.Twenty two volunteers were examined in a 3T MR system. The acquisition time of proposed EPSI protocol was 18 seconds. The EPSI scans were repeated 8 times for each subject to test reproducibility. The peak of water and individual peaks of fat including methyl, methylene, and allylic peaks at 0.9, 1.3, and 2.0 ppm were fitted. Calculated amount of water and fat content were corrected for T2 relaxation. The total HFC was defined as the combination of individual peaks. Standard deviation (SD, coefficient of variance (COV and fitting reliability of HFC quantified by LCModel were calculated.Our results show that the SDs of total HFC for all subjects are less than 2.5%. Fitting reliability is mostly under 10% and positively correlates with COV. Subjects separated into three subgroups according to quantified total HFC show that improved fitting reliability and reproducibility can be achieved on subjects with higher total HFC.We have demonstrated feasibility of the proposed EPSI protocols on the quantification of HFC over a whole slice of liver with scan time in a single breath hold.

  8. Clinical evaluation of multishot echo planar imaging after administration of superparamagnetic iron oxide for hepatic tumors

    International Nuclear Information System (INIS)

    Sugai, Yukio; Watanabe, Yorihisa; Ito, Kazushi; Hosoya, Takaaki; Yamaguchi, Koichi

    1998-01-01

    Ten cases of hepatocellular carcinoma and three cases of metastatic liver tumor were evaluated using breath-hold multishot echo planar imaging (EPI) before and after administration of super-paramagnetic iron oxide (SPIO), and the results were compared to those with breath-hold fast multi-planar SPGR (T 1 WI) and fat-suppressed respiratory-triggered FSE (T 2 WI). Qualitative imaging evaluation of lesion detectability showed that T 2 WI was much more useful than T 1 WI as previously reported, and more useful than EPI. Quantitative evaluation showed that the signal to noise (S/N) ratios of the liver parenchyma decreased after administration of SPIO and the changes were significant on all pulse sequences. The change ratio of the S/N ratio of the liver parenchyma after administration of SPIO on EPI was significantly higher than on T 1 WI and T 2 WI. The tumor-liver contrast to noise (C/N) ratios increased after administration of SPIO and the changes were significant on T 1 WI and T 2 WI, but not on EPI. These results suggested that the tumor S/N ratio decreased after administration of SPIO on EPI. The tumor diameters on EPI were significantly reduced after administration of SPIO. Magnetization and flow artifacts on EPI were detected in all cases and caused distortion: the signal decreased in the liver parenchyma. We concluded that EPI after administration of SPIO is not currently useful compared to other pulse sequences and cannot yet replace T 2 WI. (author)

  9. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Koyasu, Sho; Iima, Mami; Umeoka, Shigeaki; Morisawa, Nobuko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Porter, David A. [Siemens AG, MED MR PLM AW Neurology, Allee am Roethelheimpark 2, Erlangen (Germany); Ito, Juichi [Kyoto University, Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Le Bihan, Denis [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Neurospin, CEA-Saclay Center, Gif-sur-Yvette Cedex (France)

    2014-12-15

    To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI. We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n = 15) were also compared. The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p < 0.05), according to both semiquantitative scales and quantitative scores. There was no significant difference in ADC values and contrast-noise ratios between the two DWI techniques. The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area. (orig.)

  10. Measurement of T/sub 1/ by echo-planar imaging and the construction of computer-generated images

    Energy Technology Data Exchange (ETDEWEB)

    Mansfield, P.; Guilfoyle, D.N.; Ordidge, R.J.; Coupland, R.E.

    1986-02-01

    The high-speed echo-planar imaging (EPI) technique is used to obtain rapid T/sub 1/ and spin density measurements by a two-point method. It is shown that neglect of edge effects in the slice selection procedure leads to significant systematic errors in T/sub 1/. T/sub 1/ maps for two young patients, obtained at 4.0 MHz, are presented. The T/sub 1/ and spin density values obtained are used to produce computer-generated images in inversion recovery simulations. These results demonstrate marked improvement in image contrast without paying the time penalty incurred in real experiments, thereby greatly increasing patient throughput potential.

  11. Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

    Science.gov (United States)

    Holdsworth, Samantha J; Yeom, Kristen W; Moseley, Michael E; Skare, S

    2015-05-01

    Susceptibility-weighted imaging (SWI) in neuroimaging can be challenging due to long scan times of three-dimensional (3D) gradient recalled echo (GRE), while faster techniques such as 3D interleaved echo-planar imaging (iEPI) are prone to motion artifacts. Here we outline and implement a 3D short-axis propeller echo-planar imaging (SAP-EPI) trajectory as a faster, motion-correctable approach for SWI. Experiments were conducted on a 3T MRI system. The 3D SAP-EPI, 3D iEPI, and 3D GRE SWI scans were acquired on two volunteers. Controlled motion experiments were conducted to test the motion-correction capability of 3D SAP-EPI. The 3D SAP-EPI SWI data were acquired on two pediatric patients as a potential alternative to 2D GRE used clinically. The 3D GRE images had a better target resolution (0.47 × 0.94 × 2 mm, scan time = 5 min), iEPI and SAP-EPI images (resolution = 0.94 × 0.94 × 2 mm) were acquired in a faster scan time (1:52 min) with twice the brain coverage. SAP-EPI showed motion-correction capability and some immunity to undersampling from rejected data. While 3D SAP-EPI suffers from some geometric distortion, its short scan time and motion-correction capability suggest that SAP-EPI may be a useful alternative to GRE and iEPI for use in SWI, particularly in uncooperative patients. © 2014 Wiley Periodicals, Inc.

  12. Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

    International Nuclear Information System (INIS)

    Bruening, R.; Scheidler, J.; Porn, U.; Reiser, M.; Seelos, K.; Yousry, T.; Exner, H.; Rosen, B.R.

    1999-01-01

    The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate. (orig.)

  13. Diffusion-weighted imaging features in spinal cord infarction

    International Nuclear Information System (INIS)

    Zhang Jingsong; Huan Yi; Sun Lijun; Chang Yingjuan; Zhao Haitao; Yang Chunmin; Zhang Guangyun

    2005-01-01

    Objective: To analyze the diffusion-weighted MR imaging findings in ischemic spinal cord lesions and discuss the value of diffusion-weighted MR imaging in differentiating diagnosis with inflammatory diseases and tumors. Methods: Six patients (2 male, 4 female) with typical sudden onset of neurological deficits caused by spinal cord ischemia were evaluated. There were no definite etiologies in all patients. DW imaging was performed within 1 to 30 days after the initial neurological symptoms using a Philips Gyroscan 1.5 TMR system. Four patients had other scans including contrast-enhanced MR imaging (CE-MRI) and/or FLAIR scans. Two of them followed up with MR images in three months. All six patients were imaged using a multi-shot, navigator-corrected, echo-planar pulse sequence, and ADC values were calculated in sagittal-oriented plane. Results: MR abnormalities were demonstrated on sagittal T 2 -weighted images with 'patch-like' or 'strip-like' hyperintensities (6/6) and cord enlargement (5/6). Axial T 2 -weighted images showed bilateral (6/6) hyperintensities. In one patient only the posterior spinal artery (PSA) territory was involved. Spinal cord was mainly affected at the cervical (2/6) and thoracolumbar (4/6) region, two of them included the conus medullaris (T10-L1). DW images showed high signals in all infarct lesions, degree of intensity depended on scanning time from ill-onset and progress of illness and whether companied with hemorrhage. In this group, except one case with closely normal ADC value due to one month course of illness, the five others ADC values of lesions calculated from ADC maps arranged from 0.23 x 10 -3 mm 2 /s to 0.47 x 10 -3 mm 2 /s [average value (0.37 ± 0.10) x 10 -3 mm 2 /s], markedly lower than normal parts [ average value (0.89 ± 0.08) x 10 -3 mm 2 /s]. There were marked difference between lesions and normal regions (t=4.71, P 2 W images. Meanwhile, lesions could be displayed much better in DW images than in T 2 W images because

  14. Diffusion-weighted MR imaging of intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Bo Kiung; Na, Dong Gyu; Ryoo, Jae Wook; Byun, Hong Sik; Roh, Hong Gee; Pyeun, Yong Seon [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To document the signal characteristics of intracerebral hemorrhage (ICH) at evolving stages on diffusion-weighted images (DWI) by comparison with conventional MR images. In our retrospective study, 38 patients with ICH underwent a set of imaging sequences that included DWI, T1-and T2-weighted imaging, and fluid-attenuated inversion recovery (FLAIR). In 33 and 10 patients, respectively, conventional and echo-planar T2 gradient-echo images were also obtained. According to the time interval between symptom onset and initial MRI, five stages were categorized: hyperacute (n=6); acute (n=7); early subacute (n=7); late subacute (n=10); and chronic (n=8). We investigated the signal intensity and apparent diffusion coefficient (ADC) of ICH and compared the signal intensities of hematomas at DWI and on conventional MR images. DWI showed that hematomas were hyperintense at the hyperacute and late subacute stages, and hypointense at the acute, early subacute and chronic stages. Invariably, focal hypointensity was observed within a hyperacute hematoma. At the hyperacute, acute and early subacute stages, hyperintense rims that corresponded with edema surrounding the hematoma were present. The mean ADC ratio was 0.73 at the hyperacute stage, 0.72 at the acute stage, 0.70 at the early subacute stage, 0.72 at the late subacute stage, and 2.56 at the chronic stage. DWI showed that the signal intensity of an ICH may be related to both its ADC value and the magnetic susceptibility effect. In patients with acute stroke, an understanding of the characteristic features of ICH seen at DWI can be helpful in both the characterization of intracranial hemorrhagic lesions and the differentiation of hemorrhage from ischemia.

  15. Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

    Science.gov (United States)

    KODAMA, Nao; KOSE, Katsumi

    2016-01-01

    Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (∼54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach. PMID:27001398

  16. Characterization of Soft Tissue Tumors by Diffusion-Weighted Imaging

    International Nuclear Information System (INIS)

    Pekcevik, Yeliz; Kahya, Mehmet Onur; Kaya, Ahmet

    2015-01-01

    Diffusion-weighted imaging (DWI) is a noninvasive method for investigation of tumor histological content. It has been applied for some musculoskeletal tumors and reported to be useful. The aim of the present study was to prospectively evaluate the apparent diffusion coefficient (ADC) values of benign and malignant soft tissue tumors and to determine if ADC can help differentiate these tumors. DWI was performed on 25 histologically proven soft tissue masses. It was obtained with a single-shot echo-planar imaging technique using a 1.5T magnetic resonance (MR) machine. The mean ADC values were calculated. We grouped soft tissue tumors as benign cystic, benign solid or mixed, malignant cystic and malignant solid or mixed tumors and compared mean ADC values between these groups. There was only one patient with a malignant cystic tumor and was not included in the statistical analysis. The median ADC values of benign and malignant tumors were 2.31 ± 1.29 and 0.90 ± 0.70 (median ± interquartile range), respectively. The mean ADC values were different between benign and malignant tumors (P = 0.031). Benign cystic tumors had significantly higher ADC values than benign solid or mixed tumors and malignant solid or mixed tumors (p values were < 0.001 and 0.003, respectively). Malignant solid or mixed tumors had lower ADC values than benign solid or mixed tumors (P = 0.02). Our preliminary results have shown that although there is some overlap between benign and malignant tumors, adding DWI, MR imaging to routine soft tissue tumor protocols may improve diagnostic accuracy

  17. Fast fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging of the brain: a comparison of multi-shot echo-planar and fast spin-echo techniques

    International Nuclear Information System (INIS)

    Sargent, M.A.; Poskitt, K.J.

    1997-01-01

    Purpose. To evaluate fast spin-echo and multi-shot echo-planar fluid-attenuated inversion recovery (FLAIR) sequences in paediatric brain imaging. Materials and methods. Matched images from 32 patients with suspected tumour or white matter disease were independently evaluated by two paediatric neuroradiologists. The observer preferences for image quality and lesion detection were analysed for differences between fast spin-echo FLAIR and multi-shot echo-planar FLAIR. Diagnostic quality was compared with that of fast spin-echo T2-weighted images. Results. Images of a diagnostic quality equivalent to that of fast spin-echo T2-weighted images were achieved with both FLAIR techniques. Grey and white matter differentiation and cerebrospinal fluid (CSF) nulling were significantly better on fast spin-echo FLAIR sequences. CSF flow artefact was reduced on multi-shot echo-planar FLAIR. There was no difference in lesion detection. Fast spin-echo FLAIR images were visually preferred at the expense of longer imaging time. Conclusion. Fast FLAIR techniques are complementary to fast spin-echo T2-weighted sequences in imaging of the paediatric brain. We find that the fast spin-echo FLAIR sequence is preferable to the multi-shot echo-planar technique. (orig.). With 5 figs., 2 tabs

  18. A pilot validation of multi-echo based echo-planar correlated spectroscopic imaging in human calf muscles.

    Science.gov (United States)

    Furuyama, Jon K; Nagarajan, Rajakumar; Roberts, Christian K; Lee, Cathy C; Hahn, Theodore J; Thomas, M Albert

    2014-10-01

    A current limitation of MR spectroscopic imaging of multiple skeletal muscles is prolonged scan duration. A significant reduction in the total scan duration using the echo-planar correlated spectroscopic imaging (EP-COSI) sequence was accomplished using two bipolar readout trains with different phase-encoded echoes for one of two spatial dimensions within a single repetition time (TR). The second bipolar readout was used for spatially encoding the outer k-space, whereas the first readout was used for the central k-space only. The performance of this novel sequence, called multi-echo based echo-planar correlated spectroscopic imaging (ME-EPCOSI), was demonstrated by localizing specific key features in calf muscles and bone marrow of 11 healthy volunteers and five subjects with type 2 diabetes (T2D). A 3 T MRI-MRS scanner equipped with a transmit-receive extremity coil was used. Localization of the ME-EPCOSI sequence was in good agreement with the earlier single-readout based EP-COSI sequence and the required scan time was reduced by a factor of two. In agreement with an earlier report using single-voxel based 2D MRS, significantly increased unsaturated pools of intramyocellular lipid (IMCL) and extramyocellular lipid (EMCL) and decreased IMCL and EMCL unsaturation indices (UIs) were observed in the soleus and tibialis anterior muscle regions of subjects with T2D compared with healthy controls. In addition, significantly decreased choline content was observed in the soleus of T2D subjects compared with healthy controls. Multi-voxel characterization of IMCL and EMCL ratios and UI in the calf muscle may be useful for the non-invasive assessment of altered lipid metabolism in the pathophysiology of T2D. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Short repetition time multiband echo-planar imaging with simultaneous pulse recording allows dynamic imaging of the cardiac pulsation signal.

    Science.gov (United States)

    Tong, Yunjie; Hocke, Lia M; Frederick, Blaise deB

    2014-11-01

    Recently developed simultaneous multislice echo-planar imaging (EPI) sequences permit imaging of the whole brain at short repetition time (TR), allowing the cardiac fluctuations to be fully sampled in blood-oxygen-level dependent functional MRI (BOLD fMRI). A novel low computational analytical method was developed to dynamically map the passage of the pulsation signal through the brain and visualize the whole cerebral vasculature affected by the pulse signal. This algorithm is based on a simple combination of fast BOLD fMRI and the scanner's own built-in pulse oximeter. Multiple, temporally shifted copies of the pulse oximeter data (with 0.08 s shifting step and coverage of a 1-s span) were downsampled and used as cardiac pulsation regressors in a general linear model based analyses (FSL) of the fMRI data. The resulting concatenated z-statistics maps show the voxels that are affected as the cardiac signal travels through the brain. Many voxels were highly correlated with the pulsation regressor or its temporally shifted version. The dynamic and static cardiac pulsation maps obtained from both the task and resting state scans, resembled cerebral vasculature. The results demonstrated: (i) cardiac pulsation significantly affects most voxels in the brain; (ii) combining fast fMRI and this analytical method can reveal additional clinical information to functional studies. Copyright © 2013 Wiley Periodicals, Inc.

  20. Diffusion-weighted MR imaging in leukodystrophies

    International Nuclear Information System (INIS)

    Patay, Zoltan

    2005-01-01

    Leukodystrophies are genetically determined metabolic diseases, in which the underlying biochemical abnormality interferes with the normal build-up and/or maintenance of myelin, which leads to hypo- (or arrested) myelination, or dysmyelination with resultant demyelination. Although conventional magnetic resonance imaging has significantly contributed to recent progress in the diagnostic work-up of these diseases, diffusion-weighted imaging has the potential to further improve our understanding of underlying pathological processes and their dynamics through the assessment of normal and abnormal diffusion properties of cerebral white matter. Evaluation of conventional diffusion-weighted and ADC map images allows the detection of major diffusion abnormalities and the identification of various edema types, of which the so-called myelin edema is particularly relevant to leukodystrophies. Depending on the nature of histopathological changes, stage and progression gradient of diseases, various diffusion-weighted imaging patterns may be seen in leukodystrophies. Absent or low-grade myelin edema is found in mucopolysaccharidoses, GM gangliosidoses, Zellweger disease, adrenomyeloneuropathy, L-2-hydroxyglutaric aciduria, non-ketotic hyperglycinemia, classical phenylketonuria, Van der Knaap disease and the vanishing white matter, medium grade myelin edema in metachromatic leukodystrophy, X-linked adrenoleukodystrophy and HMG coenzyme lyase deficiency and high grade edema in Krabbe disease, Canavan disease, hyperhomocystinemias, maple syrup urine disease and leukodystrophy with brainstem and spinal cord involvement and high lactate. (orig.)

  1. Diffusion-weighted MR imaging in leukodystrophies

    Energy Technology Data Exchange (ETDEWEB)

    Patay, Zoltan [King Faisal Specialist Hospital and Research Centre, Department of Radiology, Riyadh (Saudi Arabia)

    2005-11-01

    Leukodystrophies are genetically determined metabolic diseases, in which the underlying biochemical abnormality interferes with the normal build-up and/or maintenance of myelin, which leads to hypo- (or arrested) myelination, or dysmyelination with resultant demyelination. Although conventional magnetic resonance imaging has significantly contributed to recent progress in the diagnostic work-up of these diseases, diffusion-weighted imaging has the potential to further improve our understanding of underlying pathological processes and their dynamics through the assessment of normal and abnormal diffusion properties of cerebral white matter. Evaluation of conventional diffusion-weighted and ADC map images allows the detection of major diffusion abnormalities and the identification of various edema types, of which the so-called myelin edema is particularly relevant to leukodystrophies. Depending on the nature of histopathological changes, stage and progression gradient of diseases, various diffusion-weighted imaging patterns may be seen in leukodystrophies. Absent or low-grade myelin edema is found in mucopolysaccharidoses, GM gangliosidoses, Zellweger disease, adrenomyeloneuropathy, L-2-hydroxyglutaric aciduria, non-ketotic hyperglycinemia, classical phenylketonuria, Van der Knaap disease and the vanishing white matter, medium grade myelin edema in metachromatic leukodystrophy, X-linked adrenoleukodystrophy and HMG coenzyme lyase deficiency and high grade edema in Krabbe disease, Canavan disease, hyperhomocystinemias, maple syrup urine disease and leukodystrophy with brainstem and spinal cord involvement and high lactate. (orig.)

  2. In vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) : [3,4-(CH2)-C-13] glutamate/glutamine tomography in rat brain

    NARCIS (Netherlands)

    Hyder, F; Renken, R; Rothman, DL

    1999-01-01

    A method for in vivo carbon-edited detection with proton echo-planar spectroscopic imaging (ICED PEPSI) is described. This method is composed of an echo-planar based acquisition implemented with C-13-H-1 J editing spectroscopy and is intended for high temporal and spatial resolution in vivo

  3. Snapshot gradient-recalled echo-planar images of rat brains at long echo time at 9.4 T.

    Science.gov (United States)

    Lei, Hongxia; Mlynárik, Vladimir; Just, Nathalie; Gruetter, Rolf

    2008-09-01

    With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.

  4. Diffusion weighted MR imaging of pancreatic islet cell tumors

    International Nuclear Information System (INIS)

    Bakir, Baris; Salmaslioglu, Artur; Poyanli, Arzu; Rozanes, Izzet; Acunas, Bulent

    2010-01-01

    Purpose: The aim of our study is to demonstrate the feasibility of body diffusion weighted (DW) MR imaging in the evaluation of pancreatic islet cell tumors (ICTs) and to define apparent diffusion coefficient (ADC) values for these tumors. Materials and methods: 12 normal volunteers and 12 patients with histopathologically proven pancreatic ICT by surgery were included in the study. DW MR images were obtained by a body-phased array coil using a multisection single-shot echo planar sequence on the axial plane without breath holding. In addition, the routine abdominal imaging protocol for pancreas was applied in the patient group. We measured the ADC value within the normal pancreas in control group, pancreatic ICT, and surrounding pancreas parenchyma. Mann-Whitney U-test has been used to compare ADC values between tumoral tissues and normal pancreatic tissues of the volunteers. Wilcoxon Signed Ranks Test was preferred to compare ADC values between tumoral tissues and surrounding pancreatic parenchyma of the patients. Results: In 11 patients out of 12, conventional MR sequences were able to demonstrate ICTs successfully. In 1 patient an indistinct suspicious lesion was noted at the pancreatic tail. DW sequence was able to demonstrate the lesions in all of the 12 patients. On the DW images, all ICTs demonstrated high signal intensity relative to the surrounding pancreatic parenchyma. The mean and standard deviations of the ADC values (x10 -3 mm 2 /s) were as follows: ICT (n = 12), 1.51 ± 0.35 (0.91-2.11), surrounding parenchyma (n = 11) 0.76 ± 0.15 (0.51-1.01) and normal pancreas in normal volunteers (n = 12), 0.80 ± 0.06 (0.72-0.90). ADC values of the ICT were significantly higher compared with those of surrounding parenchyma (p < 0.01) and normal pancreas (p < 0.001). Conclusion: DW MR imaging does not appear to provide significant contribution to routine MR imaging protocol in the evaluation of pancreatic islet cell tumors. But it can be added to MR imaging

  5. Diffusion weighted MR imaging of pancreatic islet cell tumors

    Energy Technology Data Exchange (ETDEWEB)

    Bakir, Baris [Department of Radiology, Istanbul University, Istanbul Medical School, Capa 34390, Istanbul (Turkey)], E-mail: drbarisbakir@yahoo.com; Salmaslioglu, Artur; Poyanli, Arzu; Rozanes, Izzet; Acunas, Bulent [Department of Radiology, Istanbul University, Istanbul Medical School, Capa 34390, Istanbul (Turkey)

    2010-04-15

    Purpose: The aim of our study is to demonstrate the feasibility of body diffusion weighted (DW) MR imaging in the evaluation of pancreatic islet cell tumors (ICTs) and to define apparent diffusion coefficient (ADC) values for these tumors. Materials and methods: 12 normal volunteers and 12 patients with histopathologically proven pancreatic ICT by surgery were included in the study. DW MR images were obtained by a body-phased array coil using a multisection single-shot echo planar sequence on the axial plane without breath holding. In addition, the routine abdominal imaging protocol for pancreas was applied in the patient group. We measured the ADC value within the normal pancreas in control group, pancreatic ICT, and surrounding pancreas parenchyma. Mann-Whitney U-test has been used to compare ADC values between tumoral tissues and normal pancreatic tissues of the volunteers. Wilcoxon Signed Ranks Test was preferred to compare ADC values between tumoral tissues and surrounding pancreatic parenchyma of the patients. Results: In 11 patients out of 12, conventional MR sequences were able to demonstrate ICTs successfully. In 1 patient an indistinct suspicious lesion was noted at the pancreatic tail. DW sequence was able to demonstrate the lesions in all of the 12 patients. On the DW images, all ICTs demonstrated high signal intensity relative to the surrounding pancreatic parenchyma. The mean and standard deviations of the ADC values (x10{sup -3} mm{sup 2}/s) were as follows: ICT (n = 12), 1.51 {+-} 0.35 (0.91-2.11), surrounding parenchyma (n = 11) 0.76 {+-} 0.15 (0.51-1.01) and normal pancreas in normal volunteers (n = 12), 0.80 {+-} 0.06 (0.72-0.90). ADC values of the ICT were significantly higher compared with those of surrounding parenchyma (p < 0.01) and normal pancreas (p < 0.001). Conclusion: DW MR imaging does not appear to provide significant contribution to routine MR imaging protocol in the evaluation of pancreatic islet cell tumors. But it can be added to

  6. Diuretic-enhanced gadolinium excretory MR urography: comparison of conventional gradient-echo sequences and echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Tacke, J.; Adam, G.B.; Haage, P.; Guenther, R.W. [Univ. of Technology, Aachen (Germany). Dept. of Diagnostic Radiology; Jung, P.; Jakse, G. [Univ. of Technology, Aachen (Germany). Dept. of Urology

    2001-01-01

    The aim of this study was to investigate the utility of different gadolinium-enhanced T1-weighted gradient-echo techniques in excretory MR urography. In 74 urologic patients, excretory MR urography was performed using various T1-weighted gradient-echo (GRE) sequences after injection of gadolinium-DTPA and low-dose furosemide. The examinations included conventional GRE sequences and echo-planar imaging (GRE EPI), both obtained with 3D data sets and 2D projection images. Breath-hold acquisition was used primarily. In 20 of 74 examinations, we compared breath-hold imaging with respiratory gating. Breath-hold imaging was significantly superior to respiratory gating for the visualization of pelvicaliceal systems, but not for the ureters. Complete MR urograms were obtained within 14-20 s using 3D GRE EPI sequences and in 20-30 s with conventional 3D GRE sequences. Ghost artefacts caused by ureteral peristalsis often occurred with conventional 3D GRE imaging and were almost completely suppressed in EPI sequences (p < 0.0001). Susceptibility effects were more pronounced on GRE EPI MR urograms and calculi measured 0.8-21.7% greater in diameter compared with conventional GRE sequences. Increased spatial resolution degraded the image quality only in GRE-EPI urograms. (orig.)

  7. Accelerated three-dimensional cine phase contrast imaging using randomly undersampled echo planar imaging with compressed sensing reconstruction.

    Science.gov (United States)

    Basha, Tamer A; Akçakaya, Mehmet; Goddu, Beth; Berg, Sophie; Nezafat, Reza

    2015-01-01

    The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Sinusoidal echo-planar imaging with parallel acquisition technique for reduced acoustic noise in auditory fMRI.

    Science.gov (United States)

    Zapp, Jascha; Schmitter, Sebastian; Schad, Lothar R

    2012-09-01

    To extend the parameter restrictions of a silent echo-planar imaging (sEPI) sequence using sinusoidal readout (RO) gradients, in particular with increased spatial resolution. The sound pressure level (SPL) of the most feasible configurations is compared to conventional EPI having trapezoidal RO gradients. We enhanced the sEPI sequence by integrating a parallel acquisition technique (PAT) on a 3 T magnetic resonance imaging (MRI) system. The SPL was measured for matrix sizes of 64 × 64 and 128 × 128 pixels, without and with PAT (R = 2). The signal-to-noise ratio (SNR) was examined for both sinusoidal and trapezoidal RO gradients. Compared to EPI PAT, the SPL could be reduced by up to 11.1 dB and 5.1 dB for matrix sizes of 64 × 64 and 128 × 128 pixels, respectively. The SNR of sinusoidal RO gradients is lower by a factor of 0.96 on average compared to trapezoidal RO gradients. The sEPI PAT sequence allows for 1) increased resolution, 2) expanded RO frequency range toward lower frequencies, which is in general beneficial for SPL, or 3) shortened TE, TR, and RO train length. At the same time, it generates lower SPL compared to conventional EPI for a wide range of RO frequencies while having the same imaging parameters. Copyright © 2012 Wiley Periodicals, Inc.

  9. Functional evaluation of the kidney by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Hasegawa, Taro; Hasegawa, Norio; Irie, Takeo; Fukuda, Kunihiko

    2003-01-01

    The purpose of this study was to determine the relationship between the apparent diffusion coefficient (ADC) and diffuse renal disease by diffusion-weighted echo planar magnetic resonance (MR) imaging (EPI). Ten volunteers, seven patients with chronic renal failure and eighteen recipients of renal transplants were examined with diffusion-weighted EPI. We compared renal function (serum creatinine level) with provided ADC value. The average ADC values were 2.63 x 10 -3 mm 2 /sec for the whole kidney, 2.67 x 10 -3 mm 2 /sec for the cortex and 2.61 x 10 -3 mm 2 /sec for the medulla in normal kidneys. ADC values in the whole kidney, the cortex and the medulla in chronic renal failure were significantly lower than those for normal kidneys. In renal transplantation kidneys, the ADC values in the cortex were significantly lower than those for normal kidney. There was a linear correlation between ADC value and serum creatinine level. Our results show that diffusion-weighted MR imaging may be useful to identify renal dysfunction. (author)

  10. Assessment of Lipid and Metabolite Changes in Obese Calf Muscle Using Multi-Echo Echo-planar Correlated Spectroscopic Imaging.

    Science.gov (United States)

    Nagarajan, Rajakumar; Carpenter, Catherine L; Lee, Cathy C; Michael, Navin; Sarma, Manoj K; Souza, Raissa; Xu, Edward; Velan, S Sendhil; Hahn, Theodore J; Go, Vay-Liang; Thomas, M Albert

    2017-12-11

    Obesity-related conditions including heart disease, stroke, and type 2 diabetes are leading causes of preventable death. Recent evidence suggests that altered myocellular lipid metabolism in obesity may lead to increased insulin resistance (IR) that predisposes to these disorders. To test the hypothesis that muscles rich in type I vs. type II muscle fibers would exhibit similar changes in intramyocellular lipid (IMCL) and extramyocellular lipid (EMCL) content in obesity, we utilized a new four-dimensional multi echo echo-planar correlated spectroscopic imaging technique that allows separate determination of IMCL and EMCL content in individual calf muscles in obese vs. normal healthy human subjects. Calf muscles were scanned in 32 obese and 11 healthy subjects using a 3T MRI/MRS scanner, and IR in the obese subjects was documented by glucose tolerance testing. In obese subjects, elevation of both IMCL and EMCL content was observed in the gastrocnemius and tibialis anterior muscles (with mixed type I and II fiber content), while a significant increase in only IMCL content (+48%, p muscle (predominantly type I fibers). These observations indicate unexpected differences in changes in myolipid metabolism in type I vs. type II rich muscle regions in obesity, perhaps related to IR, and warrant further investigation.

  11. Distortion correction of echo planar images applying the concept of finite rate of innovation to point spread function mapping (FRIP).

    Science.gov (United States)

    Nunes, Rita G; Hajnal, Joseph V

    2018-01-03

    Point spread function (PSF) mapping enables estimating the displacement fields required for distortion correction of echo planar images. Recently, a highly accelerated approach was introduced for estimating displacements from the phase slope of under-sampled PSF mapping data. Sampling schemes with varying spacing were proposed requiring stepwise phase unwrapping. To avoid unwrapping errors, an alternative approach applying the concept of finite rate of innovation to PSF mapping (FRIP) is introduced, using a pattern search strategy to locate the PSF peak, and the two methods are compared. Fully sampled PSF data was acquired in six subjects at 3.0 T, and distortion maps were estimated after retrospective under-sampling. The two methods were compared for both previously published and newly optimized sampling patterns. Prospectively under-sampled data were also acquired. Shift maps were estimated and deviations relative to the fully sampled reference map were calculated. The best performance was achieved when using FRIP with a previously proposed sampling scheme. The two methods were comparable for the remaining schemes. The displacement field errors tended to be lower as the number of samples or their spacing increased. A robust method for estimating the position of the PSF peak has been introduced.

  12. Magnetic resonance fingerprinting using echo-planar imaging: Joint quantification of T1and T2∗ relaxation times.

    Science.gov (United States)

    Rieger, Benedikt; Zimmer, Fabian; Zapp, Jascha; Weingärtner, Sebastian; Schad, Lothar R

    2017-11-01

    To develop an implementation of the magnetic resonance fingerprinting (MRF) paradigm for quantitative imaging using echo-planar imaging (EPI) for simultaneous assessment of T 1 and T2∗. The proposed MRF method (MRF-EPI) is based on the acquisition of 160 gradient-spoiled EPI images with rapid, parallel-imaging accelerated, Cartesian readout and a measurement time of 10 s per slice. Contrast variation is induced using an initial inversion pulse, and varying the flip angles, echo times, and repetition times throughout the sequence. Joint quantification of T 1 and T2∗ is performed using dictionary matching with integrated B1+ correction. The quantification accuracy of the method was validated in phantom scans and in vivo in 6 healthy subjects. Joint T 1 and T2∗ parameter maps acquired with MRF-EPI in phantoms are in good agreement with reference measurements, showing deviations under 5% and 4% for T 1 and T2∗, respectively. In vivo baseline images were visually free of artifacts. In vivo relaxation times are in good agreement with gold-standard techniques (deviation T 1 : 4 ± 2%, T2∗: 4 ± 5%). The visual quality was comparable to the in vivo gold standard, despite substantially shortened scan times. The proposed MRF-EPI method provides fast and accurate T 1 and T2∗ quantification. This approach offers a rapid supplement to the non-Cartesian MRF portfolio, with potentially increased usability and robustness. Magn Reson Med 78:1724-1733, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. [Importance of diffusion weighted magnetic resonance imaging at differentiation of cholesteatoma and granulation tissue in patients with chronic suppurative otitis media].

    Science.gov (United States)

    Tuzcu, Göksel; Yardımcı, Aytül Hande; Turna, Önder; Göner, Reyyan Elif; Acıoğlu, Engin

    2015-01-01

    This study aims to report the significance of echo-planar diffusion-weighted imaging (EP-DWI) in preoperative magnetic resonance imaging of patients with surgically corrected cholesteatoma and granulation tissue according to DWI and apparent diffusion coefficient (ADC) values. Ninety-one patients (52 males, 39 females; mean age 40.7±15.8 years; range 3 to 77 years) who admitted to radiology clinic of our hospital between December 2009 and May 2011 with a pre-diagnosis of chronic otitis media with primary acquired cholesteatoma and assessed preoperatively in our clinic by ear magnetic resonance imaging and DWI were included in the study. Diffusion-weighted imaging results were compared with operative findings and pathology results. Patients were retrospectively evaluated using picture archiving and communication system. Diffusion-weighted imaging and ADC images were examined qualitatively and quantitatively. Ninety-one patients suspected of cholesteatoma were operated. According to the results of operations, 50 patients had cholesteatoma and 41 patients had granulation tissue. The mean DWI values of patients with cholesteatoma were significantly higher than patients with granulation tissue (pgranulation tissue (p<0.05). The sensitivity and specificity of EP-DWI in detection of cholesteatoma were 97.6% and 92.0%, respectively. Echo-planar diffusion-weighted imaging by using ADC and DWI is a valuable tool with high sensitivity and specificity rates in detecting cholesteatoma particularly bigger than 5 mm and in differentiating them from other pathologies.

  14. Quantitative Mapping of Total Choline in Healthy Human Breast Using Proton Echo Planar Spectroscopic Imaging (PEPSI) at 3 Tesla

    Science.gov (United States)

    Zhao, Chenguang; Bolan, Patrick J.; Royce, Melanie; Lakkadi, Navneeth; Eberhardt, Steven; Sillerud, Laurel; Lee, Sang-Joon; Posse, Stefan

    2012-01-01

    Purpose To quantitatively measure tCho levels in healthy breasts using Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI). Material and Methods The 2-dimensional mapping of tCho at 3 Tesla across an entire breast slice using PEPSI and a hybrid spectral quantification method based on LCModel fitting and integration of tCho using the fitted spectrum were developed. This method was validated in 19 healthy females and compared with single voxel spectroscopy (SVS) and with PRESS prelocalized conventional Magnetic Resonance Spectroscopic Imaging (MRSI) using identical voxel size (8 cc) and similar scan times (~7 min). Results A tCho peak with a signal to noise ratio larger than 2 was detected in 10 subjects using both PEPSI and SVS. The average tCho concentration in these subjects was 0.45 ± 0.2 mmol/kg using PEPSI and 0.48±0.3 mmol/kg using SVS. Comparable results were obtained in 2 subjects using conventional MRSI. High lipid content in the spectra of 9 tCho negative subjects was associated with spectral line broadening of more than 26 Hz, which made tCho detection impossible. Conventional MRSI with PRESS prelocalization in glandular tissue in two of these subjects yielded tCho concentrations comparable to PEPSI. Conclusion The detection sensitivity of PEPSI is comparable to SVS and conventional PRESS-MRSI. PEPSI can be potentially used in the evaluation of tCho in breast cancer. A tCho threshold concentration value of ~0.7mmol/kg might be used to differentiate between cancerous and healthy (or benign) breast tissues based on this work and previous studies. PMID:22782667

  15. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    International Nuclear Information System (INIS)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin

    2010-01-01

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm 2 ). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  16. Diffusion-weighted MR imaging of kidneys in patients with chronic kidney disease: initial study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xueqin; Fang, Wenqiang; Ling, Huawei; Chai, Weimin; Chen, Kemin [Ruijin Hospital Shanghai, Jiaotong University School of Medicine, Department of Radiology, Shanghai (China)

    2010-04-15

    To prospectively evaluate the feasibility of diffusion-weighted (DW) magnetic resonance (MR) imaging in the assessment of renal function in patients with chronic kidney disease (CKD). Seventy-two healthy volunteers and 43 patients underwent coronal echo-planar DW MR imaging of the kidneys with a single breath-hold time of 16 s. The patients were grouped according to five stages as indicated by the K/DOQI CKD (kidney disease outcome quality initiative). The apparent diffusion coefficient (ADC) value of the kidneys was calculated with high b values (b = 500 s/mm{sup 2}). The ADC values were compared between patients and healthy volunteers, and among different stages. For statistical analysis, Student's t tests, ANOVA, Pearson's correlation tests, and Spearman's correlation tests were used. No difference between the cortex and medulla could be observed on DW images of all volunteers. Patients with CKD had significantly lower renal ADC (t = -4.383, P = 0.000) than volunteers. The ADC values of kidneys were significantly lower than normal at most stages of CKD, except CKD1. There was a negative correlation between the ADCs and serum creatinine (sCr) level (P = 0.000) amongst the patients. Diffusion-weighted MR imaging is feasible in the assessment of renal function, especially in the detection of early stage renal failure of CKD. (orig.)

  17. A parallel imaging technique using mutual calibration for split-blade diffusion-weighted PROPELLER.

    Science.gov (United States)

    Li, Zhiqiang; Pipe, James G; Aboussouan, Eric; Karis, John P; Huo, Donglai

    2011-03-01

    Split-blade diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (DW-PROPELLER) was proposed to address the issues associated with diffusion-weighted echo planar imaging such as geometric distortion and difficulty in high-resolution imaging. The major drawbacks with DW-PROPELLER are its high SAR (especially at 3T) and violation of the Carr-Purcell-Meiboom-Gill condition, which leads to a long scan time and narrow blade. Parallel imaging can reduce scan time and increase blade width; however, it is very challenging to apply standard k-space-based techniques such as GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) to split-blade DW-PROPELLER due to its narrow blade. In this work, a new calibration scheme is proposed for k-space-based parallel imaging method without the need of additional calibration data, which results in a wider, more stable blade. The in vivo results show that this technique is very promising. Copyright © 2010 Wiley-Liss, Inc.

  18. The Usefulness of Readout-Segmented Echo-Planar Imaging (RESOLVE) for Bio-phantom Imaging Using 3-Tesla Clinical MRI.

    Science.gov (United States)

    Yoshimura, Yuuki; Kuroda, Masahiro; Sugiantoc, Irfan; Bamgbosec, Babatunde O; Miyahara, Kanae; Ohmura, Yuichi; Kurozumi, Akira; Matsushita, Toshi; Ohno, Seiichiro; Kanazawa, Susumu; Asaumi, Junichi

    2018-02-01

    Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE's SNR was higher than EPI's. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE's image distortioas less than EPI's. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10-6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10-6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.

  19. Echo planar imaging in paediatrics: real-time-nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Rzedzian, R.; Doyle, M.; Mansfield, P.; Chapman, B.; Guilfoyle, D.; Coupland, R.E.; Small, P. (Universite of Nottingham (UK)); Chrispin, A. (City Hospital, Nottingham (UK))

    In 1982 Ordidge, Mansfield, Doyle and Coupland reported the first EPI movie images which were obtained using rabbits. From this study the potential use of EPI in human beings became clear. EPI is a distinctive usage of Nuclear Magnetic Resonance. Transaxial images are acquired in a very short period of time and so they are not blurred. These images accumulate in rapid sequence at each level of the anatomical transection. Each image may be linked to the events of the cardiac cycle. Construction of images in the sagittal and coronal planes may be carried out. This technique is particularly appropriate in the examination of the intrathoracic content of the infant or child. The rapidly contracting heart and the events associated with respiratory movement do not constitute a handicap to imaging the heart and great vessels and the lungs. It is this aspect of EPI which will be presented. The chambers of the heart and the great vessels may be delineated by EPI, yielding both anatomical and functional information. The pulmonary vessels may be seen in the central parts of the lungs. Alterations in proton density in the lung fields may be investigated by EPI. EPI is particularly appropriate for the examination of children for it is rapidly carried out and devoid of known hazard. Access to the patient is excellent throughout the examination.

  20. Echo planar imaging in paediatrics: real-time-nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Rzedzian, R.; Doyle, M.; Mansfield, P.; Chapman, B.; Guilfoyle, D.; Coupland, R.E.; Small, P.; Chrispin, A.

    1984-01-01

    In 1982 Ordidge, Mansfield, Doyle and Coupland reported the first EPI movie images which were obtained using rabbits. From this study the potential use of EPI in human being became clear. EPI is a distinctive usage of Nuclear Magnetic Resonance. Transaxial images are acquired in a very short period of time and so they are not blurred. These images accumulate in rapid sequence at each level of the anatomical transection. Each image may be linked to the events of the cardiac cycle. Constuction of images in the sagittal and coronal planes may be carried out. This technique is particularly appropriate in the examination of the intrathoracic content of the infant or child. The rapidly contracting heart and the events associated with respiratory movement do not constitute a handicap to imaging the heart and great vessels and the lungs. It is this aspect of EPI which will be presented. The chambers of the heart and the great vessels may be delineated by EPI, yielding both anatomical and functional information. The pulmonary vessels may be seen in the central parts of the lungs. Alterations in proton density in the lung fields may be investigated by EPI. EPI is particularly appropriate for the examination of children for it is rapidly carried out and devoid of known hazard. Access to the patient is excellent throughout the examination [fr

  1. Segmented simultaneous multi-slice diffusion weighted imaging with generalized trajectories.

    Science.gov (United States)

    Herbst, Michael; Deng, Weiran; Ernst, Thomas; Stenger, V Andrew

    2017-10-01

    The purpose of this work is to develop and evaluate a single framework for the use of Cartesian and non-Cartesian segmented trajectories for rapid and robust simultaneous multislice (SMS) diffusion weighted imaging (DWI) at 3 Telsa (T). A generalized SMS approach with intrinsic phase navigation using Multiplexed Sensitivity Encoding (MUSE) was developed. Segmented blipped-controlled aliasing in parallel imaging echo planar imaging (EPI) and z-gradient modulated spiral trajectories were examined using SMS DWI scans at 3T with a 32-channel head coil. The generalized SMS MUSE reconstruction framework was successful in significantly reducing artifacts for all trajectories. A DWI brain volume with a 67.5-mm height, 1.5-mm isotropic resolution, and 90 diffusion weightings was obtained in a scan time of 6 minutes. The MUSE technique can be generalized to allow for reconstruction of both Cartesian and non-Cartesian segmented trajectories. Magn Reson Med 78:1476-1481, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  3. Usefulness and limitation of functional MRI with echo planar imaging using clinical MR apparatus

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Zenke, Kiichiro; Saito, Masahiro; Sadamoto, Kazuhiko; Ohue, Shiro; Sakaki, Saburo; Kumon, Yoshiaki; Kabasawa, Hiroyuki; Nagasawa, Kiyoshi

    1998-01-01

    We studied blood oxygen level-dependent (BOLD) functional MRI (fMRI) with EPI sequence in 21 normal volunteers and 8 presurgical clinical patients using a 1.5 T clinical MRI apparatus. To optimize the imaging parameters, we compared the fMRI images obtained by GFE-EPI and by SE-EPI in normal volunteers while each squeezed a sponge ball. We identified the motor cortex in 85.7% of normal volunteers by GFE-EPI in contrast to only 28.6% by SE-EPI. In addition, our clinical MR apparatus, using optimized parameters, maximally provides 15 slices per 5 seconds. In patients with brain tumor close to the sensorimotor cortex, we attempted to identify the motor cortex preoperatively by this procedure and found a significant increase of signal intensity in the motor cortex in 5 of 8 patients. In conclusion, fMRI using EPI may be useful for identifying the motor cortex preoperatively. However, further development of the apparatus is needed to obtain better temporal and spatial resolution for clinical applications. (author)

  4. Echo-Planar Imaging Relaxometry to Measure the Viscosity of a Model Meal

    Science.gov (United States)

    Marciani, L.; Manoj, P.; Hills, B. P.; Moore, R. J.; Young, P.; Fillery-Travis, A.; Spiller, R. C.; Gowland, P. A.

    1998-11-01

    A method for measuring noninvasively the viscosity of a polysaccharide model meal using the known relationship between relaxation times and polysaccharide concentration in solutionin vitrois presented. The aim is to develop a method for monitoring digesta viscosityin vivo,using EPI to capture the motion of the gastrointestinal lumen. The transverse relaxation rateT-12of locust bean gum solutions was calibrated against the zero-shear viscosity at 37°C. Differences in viscosity were distinguished significantly usingT-12measurements.T-12and viscosity were insensitive to exposure to gastric juice and changes in pH, and the model meal was well received by volunteers and provided good contrastin vivoin EPI images. Therefore it would be possible to use this method to monitor the changes in meal viscosity within the gastric lumenin vivo.

  5. High temporal resolution motion estimation using a self-navigated simultaneous multi-slice echo planar imaging acquisition.

    Science.gov (United States)

    Teruel, Jose R; Kuperman, Joshua M; Dale, Anders M; White, Nathan S

    2018-02-13

    Subject motion is known to produce spurious covariance among time-series in functional connectivity that has been reported to induce distance-dependent spurious correlations. To present a feasibility study for applying the extended Kalman filter (EKF) framework for high temporal resolution motion correction of resting state functional MRI (rs-fMRI) series using each simultaneous multi-slice (SMS) echo planar imaging (EPI) shot as its own navigator. Prospective feasibility study. Three human volunteers. 3T GE DISCOVERY MR750 scanner using a 32-channel head coil. Simultaneous multi-slice rs-fMRI sequence with repetition time (TR)/echo time (TE) = 800/30 ms, and SMS factor 6. Motion estimates were computed using two techniques: a conventional rigid-body volume-wise registration; and a high-temporal resolution motion estimation rigid-body approach. The reference image was resampled using the estimates obtained from both approaches and the difference between these predicted volumes and the original moving series was summarized using the normalized mean squared error (NMSE). Direct comparison of NMSE values. High-temporal motion estimation was always superior to volume-wise motion estimation for the sample presented. For staged continuous rotations, the NMSE using high-temporal resolution motion estimates ranged between [0.130, 0.150] for the first volunteer (in-plane rotations), between [0.060, 0.068] for the second volunteer (in-plane rotations), and between [0.063, 0.080] for the third volunteer (through-plane rotations). These values went up to [0.384, 0.464]; [0.136, 0.179]; and [0.080, 0.096], respectively, when using volume-wise motion estimates. Accurate high-temporal rigid-body motion estimates can be obtained for rs-fMRI taking advantage of simultaneous multi-slice EPI sub-TR shots. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  6. SSH-EPI diffusion-weighted MR imaging of the spine with low b values: is it useful in differentiating malignant metastatic tumor infiltration from benign fracture edema?

    Science.gov (United States)

    Oztekin, Ozgur; Ozan, Ebru; Hilal Adibelli, Zehra; Unal, Gökhan; Abali, Yusuf

    2009-07-01

    Conventional MR sequences are sometimes not helpful in differentiating benign from pathologic fractures. Our aim was to evaluate the usefulness of single-shot echo-planar imaging sequences (diffusion-weighted imaging (DWI)/SSH-EPI) with low b value in differentiating malignant metastatic tumor infiltration of vertebral bone marrow from benign vertebral fracture edema. A total of 47 patients, 20 with benign fractures and 27 with tumor infiltration, were included in this prospective study. Diffusion-weighted MR images were obtained by single-shot echo-planar imaging technique with diffusion gradient (b = 300 s/mm2; TR/TE, 1,400/100), using a 1.5 T MR scanner. T1- and T2-weighted images and short inversion time inversion-recovery images were available for all 64 lesions. The lesions on DWI/SSH-EPI were categorized as having hypo-, iso-, or hyperintense signal intensity relative to normal vertebrae by two experienced radiologists. We evaluated signal intensity patterns on DWI/SSH-EPI in 64 lesions, which showed low signal intensity on T1-weighted images in both benign fractures and metastasis. With the exception of sclerotic metastases in two patients, malignant metastatic tumor infiltration was hyperintense with respect to normal bone marrow on diffusion-weighted images; all but four benign vertebral fractures were isointense with respect to normal bone marrow. Single-shot echo-planar imaging sequences (DWI/SSH-EPI) with low b value provided excellent distinction between metastatic tumor infiltration and benign vertebral fracture edema. Hyperintense signal intensity on DWI/SSH-EPI was highly specific for the diagnosis of metastatic tumor infiltration of the spine.

  7. Dynamic Multi-Coil Technique (DYNAMITE) Shimming for Echo-Planar Imaging of the Human Brain at 7 Tesla

    Science.gov (United States)

    Juchem, Christoph; Rudrapatna, S. Umesh; Nixon, Terence W.; de Graaf, Robin A.

    2014-01-01

    Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (Juchem et al., J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13 Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8 mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3 mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large

  8. MR diffusion weighted imaging with background signal suppression in breast cancer

    International Nuclear Information System (INIS)

    Li Ming; Zhang Bing; Zhou Zhengyang; Yu Haiping; Yuan Lei; Zhu Bin

    2009-01-01

    Objective: To explore the feasibility of echo planar imaging with short time inversion recovery (STIR-EPI) diffusion weighted imaging with background signal (DWIBS) suppression in breast cancer. Methods: The diffusion weighted imaging (DWI)with background suppression (b=800 mm 2 /s) was performed in 26 patients with breast cancer. Apparent diffusion coefficient(ADC) of all lesions were measured and compared. 3D maximum intensity projection (3D-MIP)and reverse black and white technique were used to show the lesions. DWI and DWIBS were performed and compared for the detection of breast cancer. Randomized blocks analysis of variance was used for the ADC values in different breast tissues, the ADC values in breast cancer and benign lesion were compared using t test. The paired chi square test was used for the detection rate of breast cancer in two different imaging methods. Results: Most of the breast cancers were hyperintense on DWI (b=800 mm 2 /s). The ADC value of cancer tissue was (0.93±0.25) x 10 -3 mm 2 /s, tumor necrosis was (2.06±0.17) x 10 -3 mm 2 /s, normal breast tissue was (1.92±0.23) x 10 -3 mm 2 /s and metastatic lymph node was (1.10±0.14) x 10 -3 mm 2 /s and the differences were statistically significant between two structures (P 2 =8.307, P 2 = 12.235, P -3 mm 2 /s and benign lesion (2.15±0.53) x 10 -3 mm 2 /s had significant statistical differences (t=8.626,P<0.05). Conclusion: Diffusion weighted MRI with background suppression can detect more lesions than DWI and can be potentially applied for the detection of the breast cancer combining the ADC value. (authors)

  9. [Utility of diffusion-weighted magnetic resonance imaging in severe focal traumatic brain injuries].

    Science.gov (United States)

    Prieto-Valderrey, F; Muñiz-Montes, J R; López-García, J A; Villegas-Del Ojo, J; Málaga-Gil, J; Galván-García, R

    2013-01-01

    To describe the apparent diffusion coefficient (ADC) in a series of severe traumatic brain injuries, their clinical and outcome features, and possible implications. A descriptive, observational case-series study was carried out. Patients with severe traumatic brain injuries (TBIs) admitted to the ICU were subjected to MRI study using a 1.5 T scanner. Diffusion-weighted images (DWMR) were obtained using the following echo-planar pulse sequence: TR 10000 ms, TE 126.9 ms, with b values 1000 s/mm2 in the three spatial dimensions. Combining the three sets of images, an isotropic image conforming a map of the mean ADCs was obtained. DWMR was performed in 23 patients with severe TBI admitted to the ICU between 2001 and 2004. In the MR images we selected 26 regions of interest (ROIs) where ADC was recorded. We observed a clear increase in diffusion in non-treated space-occupying lesions versus other types of injuries and the normal values. A poorer outcome was recorded in patients with lower ADC values. Mean ADC in the lesions was greater than the normal values and greater in contusions than in other types of injuries, as an expression of extracellular edema. ADCs were decreased in patients with a poor outcome, suggesting an association between ischemia and the patient prognosis. Copyright © 2011 Elsevier España, S.L. and SEMICYUC. All rights reserved.

  10. Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, S.; Minarikova, L.; Zaric, O.; Chmelik, M.; Strasser, B.; Trattnig, S.; Bogner, W. [Medical University Vienna, MRCE, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria); Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna (Austria); Pinker, K.; Baltzer, P.; Helbich, T. [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical imaging and Image-Guided Therapy, Vienna (Austria)

    2016-05-15

    To compare bilateral diffusion-weighted MR imaging (DWI) at 3 T and 7 T in the same breast tumour patients. Twenty-eight patients were included in this IRB-approved study (mean age 56 ± 16 years). Before contrast-enhanced imaging, bilateral DWI with b = 0 and 850 s/mm{sup 2} was performed in 2:56 min (3 T) and 3:48 min (7 T), using readout-segmented echo planar imaging (rs-EPI) with a 1.4 x 1.4 mm{sup 2} (3 T)/0.9 x 0.9 mm{sup 2} (7 T) in-plane resolution. Apparent diffusion coefficients (ADC), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were assessed. Twenty-eight lesions were detected (18 malignant, 10 benign). CNR and SNR were comparable at both field strengths (p > 0.3). Mean ADC values at 7 T were 4-22 % lower than at 3 T (p ≤ 0.03). An ADC threshold of 1.275 x 10{sup -3} mm{sup 2}/s resulted in a diagnostic specificity of 90 % at both field strengths. The sensitivity was 94 % and 100 % at 3 T and 7 T, respectively. 7-T DWI of the breast can be performed with 2.4-fold higher spatial resolution than 3 T, without significant differences in SNR if compared to 3 T. (orig.)

  11. MR diffusion weighted imaging of the prostate adenocarcinoma after endocrinotherapy: preliminary results

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Xiaoying; Li Feiyu; Guo Xuemei; Jiang Xuexiang; Guo Yulin

    2007-01-01

    Objective: To assess the changes of the apparent diffusion coefficient (ADC) values of cancerous and noncancerous regions of prostate peripheral zone in prostate cancer patients with and without endocrinotherapy. Methods: Diffusion-weighted echo-planar imaging (EPI) were performed in 32 patients with diagnosed prostate cancer, including 18 patients who were treated with endocrinotherapy over 6 months and 14 untreated matched control patients. According to the pathological results obtained by ultrasound guided biopsy, the locations of the prostate cancerous regions were marked at one or more of the sextants. The ADC values of the bladder and the obturator internus were also measured. Results: The mean ADC values of cancerous and noncancerous regions in 14 untreated controls were (1.22±0.25) x 10 -3 , (1.59 ± 0.19) x 10 -3 mm 2 /s, respectively (t=7.03, P -3 mm 2 /s in noncancerous regions, but increased to (1.46 ± 0.30) x 10 -3 mm 2 /s in cancerous regions. There still had significant difference between the cancerous and the noncancerous regions (t=2.46, P 0.05), in bladder and the obturator internus (t=0.48, 1.64; P>0.05). Conclusion: Measurement of ADCs might be useful to evaluate the efficacy of endocrinotherapy for patients with prostate cancer. (authors)

  12. Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.

    Science.gov (United States)

    Filli, Lukas; Piccirelli, Marco; Kenkel, David; Guggenberger, Roman; Andreisek, Gustav; Beck, Thomas; Runge, Val M; Boss, Andreas

    2015-07-01

    The aim of this study was to investigate the feasibility of accelerated diffusion tensor imaging (DTI) of skeletal muscle using echo planar imaging (EPI) applying simultaneous multislice excitation with a blipped controlled aliasing in parallel imaging results in higher acceleration unaliasing technique. After federal ethics board approval, the lower leg muscles of 8 healthy volunteers (mean [SD] age, 29.4 [2.9] years) were examined in a clinical 3-T magnetic resonance scanner using a 15-channel knee coil. The EPI was performed at a b value of 500 s/mm2 without slice acceleration (conventional DTI) as well as with 2-fold and 3-fold acceleration. Fractional anisotropy (FA) and mean diffusivity (MD) were measured in all 3 acquisitions. Fiber tracking performance was compared between the acquisitions regarding the number of tracks, average track length, and anatomical precision using multivariate analysis of variance and Mann-Whitney U tests. Acquisition time was 7:24 minutes for conventional DTI, 3:53 minutes for 2-fold acceleration, and 2:38 minutes for 3-fold acceleration. Overall FA and MD values ranged from 0.220 to 0.378 and 1.595 to 1.829 mm2/s, respectively. Two-fold acceleration yielded similar FA and MD values (P ≥ 0.901) and similar fiber tracking performance compared with conventional DTI. Three-fold acceleration resulted in comparable MD (P = 0.199) but higher FA values (P = 0.006) and significantly impaired fiber tracking in the soleus and tibialis anterior muscles (number of tracks, P parallel imaging results in higher acceleration can remarkably reduce acquisition time in DTI of skeletal muscle with similar image quality and quantification accuracy of diffusion parameters. This may increase the clinical applicability of muscle anisotropy measurements.

  13. Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

    Science.gov (United States)

    Ianni, Julianna D; Welch, E Brian; Grissom, William A

    2017-10-16

    To correct line-to-line delays and phase errors in echo-planar imaging (EPI). EPI-trajectory auto-corrected image reconstruction (EPI-TrACR) is an iterative maximum-likelihood technique that exploits data redundancy provided by multiple receive coils between nearby lines of k-space to determine and correct line-to-line trajectory delays and phase errors that cause ghosting artifacts. EPI-TrACR was efficiently implemented using a segmented FFT and was applied to in vivo brain data acquired at 7 T across acceleration (1×-4×) and multishot factors (1-4 shots), and in a time series. EPI-TrACR reduced ghosting across all acceleration factors and multishot factors, compared to conventional calibrated reconstructions and the PAGE method. It also achieved consistently lower ghosting in the time series. Averaged over all cases, EPI-TrACR reduced root-mean-square ghosted signal outside the brain by 27% compared to calibrated reconstruction, and by 40% compared to PAGE. EPI-TrACR automatically corrects line-to-line delays and phase errors in multishot, accelerated, and dynamic EPI. While the method benefits from additional calibration data for initialization, it was not a requirement for most reconstructions. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Diffusion-weighted MR imaging for detection of extrahepatic cholangiocarcinoma

    International Nuclear Information System (INIS)

    Cui, Xing-Yu; Chen, Hong-Wei; Cai, Song; Bao, Jian; Tang, Qun-Feng; Wu, Li-Yuan; Fang, Xiang-Ming

    2012-01-01

    Objectives: To measure the sensitivity of diffusion-weighted imaging (DWI) and determine the most appropriate b value for DWI; to explore the correlation between the apparent diffusion coefficient (ADC) value and the degree of extrahepatic cholangiocarcinoma differentiation. Methods: Preoperative diffusion-weighted imaging and magnetic resonance examinations were performed for 31 patients with extrahepatic cholangiocarcinoma. Tumor ADC values were measured, and the signal-to-noise ratio, contrast-to-noise ratio, and signal-intensity ratio between the diffusion-weighted images with various b values as well as the T2-weighted images were calculated. Pathologically confirmed patients were pathologically graded to compare the ADC value with different b values of tumor at different degrees of differentiation, and the results were statistically analyzed by using the Friedman test. Results: A total of 29 cases of extrahepatic cholangiocarcinoma were detected by DWI. As the b value increased, tumor signal-to-noise ratio and contrast-to-noise ratio between the tumor and normal liver gradually decreased, but the tumor signal-intensity ratio gradually increased. When b = 800 s/mm 2 , contrast-to-noise ratio between tumor and normal liver, tumor signal-intensity ratio, and tumor signal-to-noise ratio of diffusion-weighted images were all higher than those of T2-weighted images; the differences were statistically significant (P 2 was the best in DWI of extrahepatic cholangiocarcinoma; the lesion ADC value declined as the degree of cancerous tissue differentiation decreased.

  15. Diffusion-weighted imaging in ischaemic stroke: a follow-up study

    International Nuclear Information System (INIS)

    Weber, J.; Mattle, H.P.; Heid, O.; Remonda, L.; Schroth, G.

    2000-01-01

    Diffusion-weighted (DWI) echo-planar (EPI) MRI has been used for imaging acute ischaemic stroke. We used DWI and conventional spin-echo (SE) MRI to study the dynamics of ischaemic human stroke. We examined 30 patients (mean age 57.5 years, range 27-82 years, median 57 years) with a diagnosis of stroke. They were examined in the acute (120 min to 47 h, mean 15.3 h), subacute (8 days) and chronic (2-3 months) stages of ischaemia using clinical scores and MRI. Imaging was performed on an 1.5-T imager. Anisotropic DWI with diffusion gradients in all three axes, an isotropic tensor trace pulse DWI sequence and SE MRI were used. In all patients both DWI sequences showed a decrease in the apparent diffusion coefficient (ADC) in the acute stage, even when SE images did not reveal signal abnormalities. Clinical features correlated with lesion site but not size. The ADC was initially 19.6-43 % less than that of nonischaemic tissue and increased to normal after 7 days in conventionally treated patients and after 2-5 days in patients who underwent intra-arterial fibrinolysis. In the chronic stage the ADC rose by up to 254.4 %. In patients who did not undergo fibrinolysis DWI changes correlated with the final infarct size (P < 0.05). It was possible to differentiate acute from chronic ischaemic lesions. We conclude that DWI is a sensitive and practicable tool for detecting early cerebral ischaemia. It is possible to predict in the acute stage the final size of an infarct. DWI may be helpful for clinical decisions and for monitoring therapy. (orig.)

  16. The role of diffusion weighted magnetic resonance imaging in ...

    African Journals Online (AJOL)

    Aim of the work: To demonstrate the role of Diffusion Weighted Imaging and ADC maps in assessing normal progression of the infantile brain myelination. Patients and methods: The present work included 30 infants with normal MRI study of the brain, normal psychomotor development and normal neurological examination.

  17. Value of diffusion weighted magnetic resonance imaging in the ...

    African Journals Online (AJOL)

    Value of diffusion weighted magnetic resonance imaging in the prediction of cancer prostate. AHAA Afifi, AN Etaby, MAY Ahmad, YT Farghaly. Abstract. Introduction: Benign prostatic hyperplasia (BPH) and prostatic carcinoma (Pca) are the commonest diseases of the prostate with increased morbidities all over the world ...

  18. The role of diffusion weighted magnetic resonance imaging in ...

    African Journals Online (AJOL)

    Shaimaa R.A. Fadeel

    2015-06-16

    Jun 16, 2015 ... diffusion-weighted images and the measurement of the apparent diffusion coefficient (ADC) have been applied to the study of normal .... time msec/echo time msec); section thickness, 5 mm; intersec- tion gap, 2.5 mm; field of view, 20 cm; ..... 11. Forbes KP, Pipe JG, Bird CR. Changes in brain water diffusion.

  19. Effects of microperfusion in hepatic diffusion weighted imaging

    NARCIS (Netherlands)

    Dijkstra, Hildebrand; Baron, Paul; Kappert, Peter; Oudkerk, Matthijs; Sijens, Paul E.

    Clinical hepatic diffusion weighted imaging (DWI) generally relies on mono-exponential diffusion. The aim was to demonstrate that mono-exponential diffusion in the liver is contaminated by microperfusion and that the bi-exponential model is required. Nineteen fasting healthy volunteers were examined

  20. Characterization of chondroid matrix-forming sarcomas: gadolinium-enhanced and diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Cheng Kebin; Zhang Jing; Qu Hui; Zhang Wei; Liang Wei; Li Xiaosong; Cheng Xiaoguang; Gong Lihua

    2010-01-01

    Objective: To study the Gadolinium-enhanced MRI and diffusion weighted imaging (DWI) characteristics of the chondroid matrix-forming sarcomas. Methods: Contrast-enhanced MRI and DWI were performed in 14 cases of chondroid matrix-forming sarcomas (10 chondrosarcomas, 4 chondroblastic osteosarcomas) and 13 cases of other types of osteosarcomas. DWI was obtained with a single-shot echo-planar imaging (EPI) sequence using a 1.5 T MR imager with two different b values of 0 and 700 s/mm 2 . The apparent diffusion coefficient (ADC) values were obtained in GE Functiontool software. The contrast-enhancement pattern was evaluated and the ADC values of chondroid matrix-forming sarcomas was compared with that of other types of osteosareoma. Independent sample t-test was performed to evaluate the difference of ADC values between the group of chondroid matrix-forming sarcoma and the group of other types of osteosarcoma. In addition, nonparametric test was used to assess the difference of ADC values between the chondrosarcoma and the chondroblastic osteosarcoma. P value less than 0.05 was considered to represent a statistical significance. Results: For 14 cases of chondroid matrix-forming sarcomas, peripheral enhancement was found in all cases, septonodular enhancement was identified in 12 cases. While 13 cases of other types of osteosarcomas demonstrated heterogeneous enhancement. The mean ADC value of chondroid matrix-forming sarcomas [(2.56±0.35) x 10 -3 mm 2 /s] was significantly higher than that of other types of osteosarcoma [(1.16 ± 0.20) x 10 -3 mm 2 /s] (t=12.704, P<0.01). There was no significant difference in the ADC value between the chondrosarcoma and the chondroblastic osteosarcoma (Z=0.507, P=0.959). Conclusion: Contrast-enhanced MRI and DWI can improve differentiation between chondroid matrix-forming sarcomas and other types of osteosarcomas. (authors)

  1. Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis.

    Science.gov (United States)

    Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos

    2015-01-01

    Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm 2 . ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm 2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm 2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm 2 ) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10 -3 mm 2 /s. 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.

  2. Echo-Planar Imaging Based J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2013-10-01

    fat. Artif Cells Blood Substit Immobil Biotechnol. 1994;22(4): 1477–83. 12. Maio A, Rifkin MD. Magnetic resonance imaging of prostate cancer...Med. Imaging 2011; 30: 1100–1115. 97. Wu B, Millane RP, Watts R, Bones PJ. Prior estimate based com- pressed sensing in parallel MRI. Magn. Reson

  3. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2016-12-01

    Huda A, Nagarajan R, Furuyama J and Thomas MA. In Vivo Two-Dimensional Magnetic Resonance Spectroscopy "Comprehensive Biomedical Physics " Elsevier...planar spectroscopic imaging of J-coupled resonances in human brain at 3 and 4 Tesla . Magn Reson Med 2007; 58(2): 236-44. PMID: 17610279 14...1981;29:1153-1160. 7. Brüschweiler R, Zhang F. Covariance nuclear magnetic resonance spectroscopy. The Journal of chemical physics 2004;120:5253-5260. 8

  4. Prior-knowledge Fitting of Accelerated Five-dimensional Echo Planar J-resolved Spectroscopic Imaging: Effect of Nonlinear Reconstruction on Quantitation.

    Science.gov (United States)

    Iqbal, Zohaib; Wilson, Neil E; Thomas, M Albert

    2017-07-24

    1 H Magnetic Resonance Spectroscopic imaging (SI) is a powerful tool capable of investigating metabolism in vivo from mul- tiple regions. However, SI techniques are time consuming, and are therefore difficult to implement clinically. By applying non-uniform sampling (NUS) and compressed sensing (CS) reconstruction, it is possible to accelerate these scans while re- taining key spectral information. One recently developed method that utilizes this type of acceleration is the five-dimensional echo planar J-resolved spectroscopic imaging (5D EP-JRESI) sequence, which is capable of obtaining two-dimensional (2D) spectra from three spatial dimensions. The prior-knowledge fitting (ProFit) algorithm is typically used to quantify 2D spectra in vivo, however the effects of NUS and CS reconstruction on the quantitation results are unknown. This study utilized a simulated brain phantom to investigate the errors introduced through the acceleration methods. Errors (normalized root mean square error >15%) were found between metabolite concentrations after twelve-fold acceleration for several low concentra- tion (OGM) human brain matter were quantified in vivo using the 5D EP-JRESI sequence with eight-fold acceleration.

  5. Echo-Planar Imaging-Based, J-Resolved Spectroscopic Imaging for Improved Metabolite Detection in Prostate Cancer

    Science.gov (United States)

    2016-12-01

    the spectrum shown in Fig. 4b, the (Cr+Spm+Cho)/Cit was calculated to be 0.395. The mean (Cr+Spm+Cho)/Cit value for all six volunteers from a sim - ilar...Ding Y, Maher EA, Sims RD, Choi C, Lewis MA, Kodibagkar VD. Compressive sensing could accelerate 1H MR metabolic imaging in the clinic. Radiology 2012...sequence utilizing maximum-echo sampling for acquisition (highlighted in gold ; FID; ADC, analog-to-digital converter). Half-echo sampling is started exactly

  6. High spatial resolution diffusion weighted imaging on clinical 3 T MRI scanners using multislab spiral acquisitions.

    Science.gov (United States)

    Holtrop, Joseph L; Sutton, Bradley P

    2016-04-01

    A diffusion weighted imaging (DWI) approach that is signal-to-noise ratio (SNR) efficient and can be applied to achieve sub-mm resolutions on clinical 3 T systems was developed. The sequence combined a multislab, multishot pulsed gradient spin echo diffusion scheme with spiral readouts for imaging data and navigators. Long data readouts were used to keep the number of shots, and hence total imaging time, for the three-dimensional acquisition short. Image quality was maintained by incorporating a field-inhomogeneity-corrected image reconstruction to remove distortions associated with long data readouts. Additionally, multiple shots were required for the high-resolution images, necessitating motion induced phase correction through the use of efficiently integrated navigator data. The proposed approach is compared with two-dimensional (2-D) acquisitions that use either a spiral or a typical echo-planar imaging (EPI) acquisition to demonstrate the improved SNR efficiency. The proposed technique provided 71% higher SNR efficiency than the standard 2-D EPI approach. The adaptability of the technique to achieve high spatial resolutions is demonstrated by acquiring diffusion tensor imaging data sets with isotropic resolutions of 1.25 and 0.8 mm. The proposed approach allows for SNR-efficient sub-mm acquisitions of DWI data on clinical 3 T systems.

  7. Diffusion-weighted imaging in acute demyelinating myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Zecca, Chiara; Cereda, Carlo; Tschuor, Silvia; Staedler, Claudio; Nadarajah, Navarajah; Bassetti, Claudio L.; Gobbi, Claudio [Ospedale Regionale di Lugano, Servizio di Neurologia e Neuroradiologia, Neurocenter of Southern Switzerland, Lugano (Switzerland); Wetzel, Stephan [Swiss Neuro Institute (SNI), Abteilung fuer Neuroradiologie, Hirslanden Klinik Zuerich, Zuerich (Switzerland); Santini, Francesco [University of Basel Hospital, Division of Radiological Physics, Basel (Switzerland)

    2012-06-15

    Diffusion-weighted imaging (DWI) has become a reference MRI technique for the evaluation of neurological disorders. Few publications have investigated the application of DWI for inflammatory demyelinating lesions. The purpose of the study was to describe diffusion-weighted imaging characteristics of acute, spinal demyelinating lesions. Six consecutive patients (two males, four females; aged 28-64 years) with acute spinal cord demyelinating lesions were studied in a prospective case series design from June 2009 to October 2010. We performed magnetic resonance imaging studies from 2 to 14 days from symptom onset on the patients with relapsing remitting multiple sclerosis (n = 3) or clinically isolated syndrome (n = 3). Main outcome measures were diffusion-weighted imaging and apparent diffusion coefficient pattern (ADC) of acute spinal cord demyelinating lesions. All spinal lesions showed a restricted diffusion pattern (DWI+/ADC-) with a 24% median ADC signal decrease. A good correlation between clinical presentation and lesion site was observed. Acute demyelinating spinal cord lesions show a uniform restricted diffusion pattern. Clinicians and neuro-radiologists should be aware that this pattern is not necessarily confirmatory for an ischaemic aetiology. (orig.)

  8. Diffusion-weighted imaging in acute demyelinating myelopathy

    International Nuclear Information System (INIS)

    Zecca, Chiara; Cereda, Carlo; Tschuor, Silvia; Staedler, Claudio; Nadarajah, Navarajah; Bassetti, Claudio L.; Gobbi, Claudio; Wetzel, Stephan; Santini, Francesco

    2012-01-01

    Diffusion-weighted imaging (DWI) has become a reference MRI technique for the evaluation of neurological disorders. Few publications have investigated the application of DWI for inflammatory demyelinating lesions. The purpose of the study was to describe diffusion-weighted imaging characteristics of acute, spinal demyelinating lesions. Six consecutive patients (two males, four females; aged 28-64 years) with acute spinal cord demyelinating lesions were studied in a prospective case series design from June 2009 to October 2010. We performed magnetic resonance imaging studies from 2 to 14 days from symptom onset on the patients with relapsing remitting multiple sclerosis (n = 3) or clinically isolated syndrome (n = 3). Main outcome measures were diffusion-weighted imaging and apparent diffusion coefficient pattern (ADC) of acute spinal cord demyelinating lesions. All spinal lesions showed a restricted diffusion pattern (DWI+/ADC-) with a 24% median ADC signal decrease. A good correlation between clinical presentation and lesion site was observed. Acute demyelinating spinal cord lesions show a uniform restricted diffusion pattern. Clinicians and neuro-radiologists should be aware that this pattern is not necessarily confirmatory for an ischaemic aetiology. (orig.)

  9. Diffusion weighted whole body imaging with background body signal suppression (DWIBS). Technical improvement using free breathing, STIR and high resolution 3D display

    International Nuclear Information System (INIS)

    Takahara, Taro; Imai, Yutaka; Yamashita, Tomohiro; Yasuda, Seiei; Nasu, Seiji; Cauteren, M. Van

    2004-01-01

    The purpose of this study was to examine a new way of body diffusion weighted imaging (DWI) using the short TI inversion recovery-echo planar imaging (STIR-EPI) sequence and free breathing scanning (diffusion weighted whole body imaging with background body signal suppression; DWIBS) to obtain three-dimensional displays. Apparent contrast-to-noise ratios (AppCNR) between lymph nodes and surrounding fat tissue were compared in three types of DWI with and without breath-holding, with variable lengths of scan time and slice thickness. The STIR-EPI sequence and spin echo-echo planar imaging (SE-EPI) sequence with chemical shift selective (CHESS) pulse were compared in terms of their degree of fat suppression. Eleven patients with neck, chest, and abdominal malignancy were scanned with DWIBS for evaluation of feasibility. Whole body imaging was done in a later stage of the study using the peripheral vascular coil. The AppCNR of 8 mm slice thickness images reconstructed from 4 mm slice thickness source images obtained in a free breathing scan of 430 sec were much better than 9 mm slice thickness breath-hold scans obtained in 25 sec. High resolution multi-planar reformat (MPR) and maximum intensity projection (MIP) images could be made from the data set of 4 mm slice thickness images. Fat suppression was much better in the STIR-EPI sequence than SE-EPI with CHESS pulse. The feasibility of DWIBS was showed in clinical scans of 11 patients. Whole body images were successfully obtained with adequate fat suppression. Three-dimensional DWIBS can be obtained with this technique, which may allow us to screen for malignancies in the whole body. (author)

  10. Diffusion-Weighted Magnetic Resonance Imaging in Renal Lesion Characterization

    Directory of Open Access Journals (Sweden)

    Elif Karadeli

    2012-03-01

    Conclusion: The technique has the advantage that it is non-invasive without need for gadolinium administration, takes about 2 minute. This method provides qualitative and quantitative infomation on tissue characterization. DA-MRI and ADC values are important for characterization of renal lesions. Especially, utility of diffusion-weighted magnetic resonance imaging in the patients with risk for nephrogenic systemic fibrosis (NSF could be beneficial. [Cukurova Med J 2012; 37(1: 27-36

  11. Diffusion-weighted MR imaging findings in carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Teksam, M.; Casey, S.O.; Michel, E.; Liu, H.; Truwit, C.L.

    2002-01-01

    Diffusion-weighted MR imaging (DWI) of two patients with carbon monoxide (CO) poisoning demonstrated white matter and cortical hyperintensities. In one patient, the changes on the FLAIR sequence were more subtle than those on DWI. The DWI abnormality in this patient represented true restriction. In the second patient, repeated exposure to CO caused restricted diffusion. DWI may be helpful for earlier identification of the changes of acute CO poisoning. (orig.)

  12. Combination of chemical suppression techniques for dual suppression of fat and silicone at diffusion-weighted MR imaging in women with breast implants

    International Nuclear Information System (INIS)

    Koh, Dow-Mu; Hughes, J.; Blackledge, M.; Leach, M.O.; Collins, D.J.; Burns, S.; Stemmer, A.; Kiefer, B.

    2012-01-01

    Silicone breast prostheses prove technically challenging when performing diffusion-weighted MR imaging in the breasts. We describe a combined fat and chemical suppression scheme to achieve dual suppression of fat and silicone, thereby improving the quality of diffusion-weighted images in women with breast implants. MR imaging was performed at 3.0 and 1.5 T in women with silicone breast implants using short-tau inversion recovery (STIR) fat-suppressed echo-planar (EPI) diffusion-weighted MR imaging (DWI) on its own and combined with the slice-select gradient-reversal (SSGR) technique. Imaging was performed using dedicated breast imaging coils. Complete suppression of the fat and silicone signal was possible at 3.0 T using EPI DWI with STIR and SSGR, evaluated with dedicated breast coils. However, a residual silicone signal was still perceptible at 1.5 T using this combined approach. Nevertheless, a further reduction in silicone signal at 1.5 T could be achieved by employing thinner slice partitions and the addition of the chemical-selective fat-suppression (CHESS) technique. DWI using combined STIR and SSGR chemical suppression techniques is feasible to eliminate or reduce silicone signal from prosthetic breast implants. (orig.)

  13. BOLD contrast fMRI of whole rodent tumour during air or carbogen breathing using echo-planar imaging at 1.5 T

    Energy Technology Data Exchange (ETDEWEB)

    Landuyt, W.; Bogaert, W. van den; Lambin, P. [Lab. of Experimental Radiobiology and Department of Radiotherapy/Oncology,Univ. Hospitals Leuven (Belgium); Hermans, R.; Bosmans, H.; Sunaert, S.; Beatse, E.; Farina, D.; Meijerink, M.; Zhang, H.; Marchal, G. [University Hospital, Leuven (Belgium). Dept. of Radiology

    2001-11-01

    The aim of this study was to evaluate the feasibility of functional MR imaging (fMRI) at 1.5 T, exploiting blood oxygenation level-dependent (BOLD) contrast, for detecting changes in whole-tumour oxygenation induced by carbogen (5% CO{sub 2}+95% O{sub 2}) inhalation of the host. Adult WAG/Rij rats with rhabdomyosarcomas growing subcutaneously in the lower flank were imaged when tumours reached sizes between 1 and 11 cm{sup 3} (n=12). Air and carbogen were alternatively supplied at 2 l/min using a snout mask. Imaging was done on a 1.5-T MR scanner using a T2*-weighted gradient-echo, echo-planar imaging (GE-EPI) sequence. Analysis of the whole-tumour EPI images was based on statistical parametric maps. Voxels with and without signal intensity changes (SIC) were recorded. Significance thresholds were set at p<0.05, corrected for multiple comparisons. In continuous air breathing condition, 3 of 12 tumours showed significant negative SIC and 1 tumour had a clear-cut positive SIC. The remaining tumours showed very little or no change. When switching to carbogen breathing, the SIC were significantly positive in 10 of 12 tumours. Negative SIC were present in 4 tumours, of which three were simultaneously characterised by positive SIC. The overall analysis indicated that 6 of the 12 tumours could be considered as strong positive responders to carbogen. Our research demonstrates the applicability of fMRI GE-EPI at 1.5 T to study whole-tumour oxygenation non-invasively. The observed negative SIC during air condition may reflect the presence of transient hypoxia during these measurements. Selection of tumours on the basis of their individual response to carbogen is possible, indicating a role of such non-invasive measurements for using tailor-made treatments. (orig.)

  14. Reversible diffusion weighted imaging changes in propionic acidemia.

    Science.gov (United States)

    Kandel, Amit; Amatya, Sirisa Kandel; Yeh, E Ann

    2013-01-01

    Propionic acidemia is an inborn error of metabolism with neurologic manifestations. We describe a 3-year-old boy with propionic acidemia presenting with a metabolic crisis including headache, vomiting, and altered mental status with metabolic acidosis. Electroencephalography showed focal slowing in right temporal region. Magnetic resonance imaging (MRI) of the brain showed restricted diffusion with apparent diffusion coefficient correlate in the right parietooccipital region. Correction of metabolic acidosis led to clinical improvement and normalization of MRI diffusion weighted imaging/apparent diffusion coefficient changes. This article suggests that restricted diffusion resulting from metabolic crises in propionic acidemia may be reversible in some cases.

  15. The value of diffusion-weighted imaging for prediction of lasting deficit in acute stroke: an analysis of 134 patients with acute neurologic deficits

    International Nuclear Information System (INIS)

    Wiener, J.I.; King, J.T. Jr.; Moore, J.R.; Lewin, J.S.

    2001-01-01

    Acute stroke is one of the three major causes of death and disability in the United States. Now that new, and possibly effective therapy is becoming available, accurate, rapid diagnosis is important to provide timely treatment, while avoiding the risk of complications from unnecessary intervention. Our objective was to test the hypothesis that use of echo-planar (EPI) diffusion-weighted imaging (DWI) is more accurate than conventional T 2 weighted MRI in predicting progression to stroke in patients with acute ischemic neurologic deficits. We studied 134 patients presenting with acute neurologic deficits to a community hospital emergency room with both conventional MRI and DWI within 72 h of the onset of the acute deficit. We found DWI significantly more sensitive to permanent neurologic deficit at discharge (sensitivity 0.81) than conventional MRI (sensitivity 0.41). When available, DWI should be considered for routine use in patients being imaged for acute stroke. (orig.)

  16. Progressive multifocal leukoencephalopathy: diffusion-weighted imaging and pathological correlations.

    Science.gov (United States)

    Bergui, M; Bradac, G B; Oguz, K K; Boghi, A; Geda, C; Gatti, G; Schiffer, D

    2004-01-01

    We examined MRI of two patients with progressive multifocal leukoencephalopathy (PML), including diffusion-weighted imaging (DWI), with calculation of apparent diffusion coefficients (ADC). The pathology findings of one patient were compared with those of MRI. The lesions had different ADC and DWI appearances, depending on the stage of the disease. Newer lesions and the advancing edge of large lesions had normal-to-low ADC and gave high signal on DWI. Older lesions and the centre of large lesions had increased ADC and gave low signal. High signal on DWI and low ADC mark the regions of active infection and cell swelling, distinguishing them from areas of reparative gliosis.

  17. Progressive multifocal leukoencephalopathy: diffusion-weighted imaging and pathological correlations

    Energy Technology Data Exchange (ETDEWEB)

    Bergui, M.; Bradac, G.B.; Boghi, A. [Department of Neuroradiology, University of Turin, Via Cherasco 15, 10126, Torino (Italy); Oguz, K.K. [Department of Radiology, Hacettepe University, Sihhiye, Ankara (Turkey); Geda, C.; Gatti, G. [Chivasso General Hospital, Torino (Italy); Schiffer, D. [Department of Neuropathology, University of Turin, Via Cherasco 15, 10126, Torino (Italy)

    2004-01-01

    We examined MRI of two patients with progressive multifocal leukoencephalopathy (PML), including diffusion-weighted imaging (DWI), with calculation of apparent diffusion coefficients (ADC). The pathology findings of one patient were compared with those of MRI. The lesions had different ADC and DWI appearances, depending on the stage of the disease. Newer lesions and the advancing edge of large lesions had normal-to-low ADC and gave high signal on DWI. Older lesions and the centre of large lesions had increased ADC and gave low signal. High signal on DWI and low ADC mark the regions of active infection and cell swelling, distinguishing them from areas of reparative gliosis. (orig.)

  18. Diffusion-weighted breast imaging at 3 T: Preliminary experience

    International Nuclear Information System (INIS)

    Nogueira, L.; Brandão, S.; Matos, E.; Nunes, R.G.; Ferreira, H.A.; Loureiro, J.; Ramos, I.

    2014-01-01

    Aim: To evaluate the performance of diffusion-weighted imaging (DWI) at 3 T for the detection and characterization of breast lesions. Materials and methods: Magnetic resonance imaging (MRI) of the breast, including DWI single-shot spin-echo echo planar images (SS-SE-EPI; eight b-values, 50–3000 s/mm 2 ), were acquired in women with a clinical indication for breast MRI. The exclusion criteria were as follows: (1) previous breast surgery, radiotherapy and/or chemotherapy within the prior 48 months (14 women); (2) only cystic lesions (one woman); (3) no detectable enhancing lesion at dynamic contrast-enhanced (DCE)-MRI (15 women); and (4) breast implants (four women). MRI results were corroborated by histopathology or imaging follow-up. Apparent diffusion coefficients (ADCs) were estimated for lesions and normal glandular tissue. Differences in the ADC between tissue types were evaluated and the sensitivity and specificity of the method calculated by receiver operating characteristics (ROC) curves. Results: The final cohort comprised 53 patients with 59 lesions. Histopathology was obtained for 58 lesions. One lesion was validated as benign on imaging follow-up. Mean ADCs of 1.99 ± 0.27 × 10 −3  mm 2 /s, 1.08 ± 0.25 × 10 −3  mm 2 /s, and 1.74 ± 0.35 × 10 −3  mm 2 /s were obtained for normal tissue, malignant, and benign lesions, respectively. Mean ADCs of malignancies were significantly lower than those of benign lesions (p < 0.001) and normal tissue (p < 0.0001). The sensitivity and specificity for stratifying lesions, considering an ADC threshold of 1.41 × 10 −3  mm 2 /s, were 94.3% and 87.5%, respectively; accuracy was 91.5%. Conclusion: DWI proved useful for the detection and characterization of breast lesions in the present sample. ADC values provide a high diagnostic performance for differentiation between benign and malignant lesions

  19. Effect of Task-Correlated Physiological Fluctuations and Motion in 2D and 3D Echo-Planar Imaging in a Higher Cognitive Level fMRI Paradigm.

    Science.gov (United States)

    Ladstein, Jarle; Evensmoen, Hallvard R; Håberg, Asta K; Kristoffersen, Anders; Goa, Pål E

    2016-01-01

    To compare 2D and 3D echo-planar imaging (EPI) in a higher cognitive level fMRI paradigm. In particular, to study the link between the presence of task-correlated physiological fluctuations and motion and the fMRI contrast estimates from either 2D EPI or 3D EPI datasets, with and without adding nuisance regressors to the model. A signal model in the presence of partly task-correlated fluctuations is derived, and predictions for contrast estimates with and without nuisance regressors are made. Thirty-one healthy volunteers were scanned using 2D EPI and 3D EPI during a virtual environmental learning paradigm. In a subgroup of 7 subjects, heart rate and respiration were logged, and the correlation with the paradigm was evaluated. FMRI analysis was performed using models with and without nuisance regressors. Differences in the mean contrast estimates were investigated by analysis-of-variance using Subject, Sequence, Day, and Run as factors. The distributions of group level contrast estimates were compared. Partially task-correlated fluctuations in respiration, heart rate and motion were observed. Statistically significant differences were found in the mean contrast estimates between the 2D EPI and 3D EPI when using a model without nuisance regressors. The inclusion of nuisance regressors for cardiorespiratory effects and motion reduced the difference to a statistically non-significant level. Furthermore, the contrast estimate values shifted more when including nuisance regressors for 3D EPI compared to 2D EPI. The results are consistent with 3D EPI having a higher sensitivity to fluctuations compared to 2D EPI. In the presence partially task-correlated physiological fluctuations or motion, proper correction is necessary to get expectation correct contrast estimates when using 3D EPI. As such task-correlated physiological fluctuations or motion is difficult to avoid in paradigms exploring higher cognitive functions, 2D EPI seems to be the preferred choice for higher

  20. Assessment of cerebral blood flow reserve using blood oxygen level-dependent echo planar imaging after acetazolamide administration in patients post-STA-MCA anastomosis surgery

    International Nuclear Information System (INIS)

    Zenke, Kiichiro; Kusunoki, Katsusuke; Saito, Masahiro; Sadamoto, Kazuhiko; Ohta, Shinsuke; Kumon, Yoshiaki; Sakaki, Saburo; Nagasawa, Kiyoshi

    1998-01-01

    Recently, blood oxygen level-dependent (BOLD) echo planar imaging (EPI) has been used to estimate blood flow changes. Theoretically, a relative decrement of deoxyhemoglobin in cerebral blood supply induces a MR signal change after neuronal stimulation. In the present study, we have attempted to evaluate CBF reserve capacity by the BOLD EPI in patients who had undergone STA-MCA anastomosis surgery. Then, we compared with the signal intensity changes obtained by this procedure with the CBF changes by Xe-SPECT after acetazolamide administration. Six patients, post-STA-MCA anastomosis surgery, were studied. Pre-operatively, MR signal intensity and CBF, by Xe-SPECT, were increased in the intact side after acetazolamide administration in all patients, and MR signal intensities were decreased in low flow regions after acetazolamide administration in all four patients in whom so-called steal phenomenon was demonstrated by Xe-SPECT study. Post-operatively, poor response was shown after acetazolamide administration with both Xe-SPECT and BOLD EPI in the two patients who had unsuccessful anastomoses. In the successfully anastomosed patients, improved vascular reactivity was demonstrated on BOLD EPI after acetazolamide administration in 3 of 4 patients in whom an improvement of vascular reactivity was demonstrated on Xe-SPECT. In one patient, MRI studies were considered to have technical artifacts, because the MR signal intensity did not increase, even in the intact side after acetazolamide administration. In conclusion, BOLD EPI after acetazolamide administration is an useful procedure for the pre- and post-operative of vascular reserve in patients with ischemic stroke. (author)

  1. Diffusion-weighted imaging in neuroradiology; Diffusionsgewichtung in der Neuroradiologie

    Energy Technology Data Exchange (ETDEWEB)

    Schlamann, M. [Universitaetsklinikum Essen, Institut fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Essen (Germany)

    2011-03-15

    Diffusion-weighted imaging is becoming increasingly more important in neuroradiology. Formerly this technique was mainly used in stroke diagnostics but the spectrum of applications is becoming increasingly larger. Diffusion-weighted imaging is a useful tool for differentiation between metastases and abscesses, for assessment of the depth of invasiveness of tumors and to differentiate inflammation from astrocytomas. It has now become a standard technique in multiple sclerosis imaging. A further advantage in addition to the diagnostic capabilities is the speed of the sequence which makes it insensitive to movement artefacts. (orig.) [German] Die Diffusionsgewichtung erhaelt in der Neuroradiologie einen immer hoeheren Stellenwert. War sie frueher hauptsaechlich in der Schlaganfalldiagnostik verbreitet, erweitert sich das Anwendungsspektrum immer mehr. Die Diffusionsgewichtung ist sowohl ein hilfreiches Werkzeug zur Differenzierung zwischen Metastasen und Abszessen als auch zur Beurteilung der Invasionstiefe von Tumoren oder zur Unterscheidung von Entzuendungen und Astrozytomen. Sie gehoert mittlerweile zum Standard in der MS-Bildgebung. Ein weiterer Vorteil neben der diagnostischen Aussagekraft ist die Schnelligkeit der Sequenz, die damit sehr unempfindlich gegenueber Bewegungsartefakten ist. (orig.)

  2. Diffusion weighted imaging in cystic fibrosis disease: beyond morphological imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ciet, Pierluigi [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center - Sophia Children' s Hospital, Department of Paediatrics, Respiratory Medicine and Allergology, P.O. Box 2060, Rotterdam, Zuid-Holland (Netherlands); Ca' Foncello - General Hospital, Department of Radiology, Treviso (Italy); Serra, Goffredo; Catalano, Carlo [University of Rome ' ' Sapienza' ' , Department of Radiology, Rome (Italy); Andrinopoulou, Eleni Rosalina [Erasmus Medical Center, Department of Biostatistics, Rotterdam (Netherlands); Bertolo, Silvia; Morana, Giovanni [Ca' Foncello - General Hospital, Department of Radiology, Treviso (Italy); Ros, Mirco [Ca' Foncello Hospital, Department of Pediatrics, Treviso (Italy); Colagrande, Stefano [University of Florence - Azienda Ospedaliero-Universitaria Careggi, Department of Experimental and Clinical Biomedical Sciences, Radiodiagnostic Unit n. 2, Florence (Italy); Tiddens, Harm A.W.M. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center - Sophia Children' s Hospital, Department of Paediatrics, Respiratory Medicine and Allergology, P.O. Box 2060, Rotterdam, Zuid-Holland (Netherlands)

    2016-11-15

    To explore the feasibility of diffusion-weighted imaging (DWI) to assess inflammatory lung changes in patients with Cystic Fibrosis (CF) CF patients referred for their annual check-up had spirometry, chest-CT and MRI on the same day. MRI was performed in a 1.5 T scanner with BLADE and EPI-DWI sequences (b = 0-600 s/mm{sup 2}). End-inspiratory and end-expiratory scans were acquired in multi-row scanners. DWI was scored with an established semi-quantitative scoring system. DWI score was correlated to CT sub-scores for bronchiectasis (CF-CT{sub BE}), mucus (CF-CT{sub mucus}), total score (CF-CT{sub total-score}), FEV{sub 1}, and BMI. T-test was used to assess differences between patients with and without DWI-hotspots. Thirty-three CF patients were enrolled (mean 21 years, range 6-51, 19 female). 4 % (SD 2.6, range 1.5-12.9) of total CF-CT alterations presented DWI-hotspots. DWI-hotspots coincided with mucus plugging (60 %), consolidation (30 %) and bronchiectasis (10 %). DWI{sub total-score} correlated (all p < 0.0001) positively to CF-CT{sub BE} (r = 0.757), CF-CT{sub mucus} (r = 0.759) and CF-CT{sub total-score} (r = 0.79); and negatively to FEV{sub 1} (r = 0.688). FEV{sub 1} was significantly higher (p < 0.0001) in patients without DWI-hotspots. DWI-hotspots strongly correlated with radiological and clinical parameters of lung disease severity. Future validation studies are needed to establish the exact nature of DWI-hotspots in CF patients. (orig.)

  3. Utility of echo-planar gradient-echo T2*-weighted MR images in patients with primary intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Yokoe, Toshio; Yoshida, Tazuka; Kobayashi, Nozomu; Nakamura, Yukihiro; Kubota, Kazuyuki

    2005-01-01

    Magnetic resonance imaging (MRI) has the potential to reveal residues of intracerabral hemorrhage (ICH) throughout life because of the high sensitivity for iron-containing compounds. Gradient-echo T2 * -weighted MR imaging (T2 * MRI) requiring short times for complete acquisition is known to detect small areas of signal loss without surrounding edema representing microbleeds (MBs). MBs in the basal ganglia including the thalami are suggested to be closely related to intracerebral atherosclerotic microangiopathy. We looked for more than 3 MBs in basal ganglia or thalamus of patients with and without episodes of previous ICH. Twelve patients with previous hemorrhagic stroke and 82 without were studied. Multiple MBs in those regions were significantly more frequent in patients with recurrent ICH. In addition, a 76-year-old woman with a history of hypertension was transferred to our hospital for treatment of head injury. She had multiple incidental old basal ganglionic and thalamic MBs. The patient had an asymptomatic primary ICH on computed tomography (CT) 3 months later. In conclusion, MR evidence of multiple MBs in the basal ganglia and thalamus might identify patients at a risk for new and recurrent ICH. Therefore, patients with multiple MBs in those regions should be treated for cerebrovascular risk factors, especially hypertension. Our results appear to confirm the utility of T2 * MRI in hemorrhagic stroke. (author)

  4. Role of diffusion weighted imaging in musculoskeletal infections: Current perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Yogesh [Yale New Haven Health System at Bridgeport Hospital, Department of Radiology, Bridgeport, CT (United States); Khaleel, Mohammad [UT Southwestern Medical Center, Department of Orthopaedic Surgery, Dallas, TX (United States); Boothe, Ethan; Awdeh, Haitham [UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Department of Radiology, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Department of Orthopaedic Surgery, Dallas, TX (United States); UT Southwestern Medical Center, Department of Radiology, Dallas, TX (United States)

    2017-01-15

    Accurate diagnosis and prompt therapy of musculoskeletal infections are important prognostic factors. In most cases, clinical history, examination and laboratory findings help one make the diagnosis, and routine magnetic resonance imaging (MRI) is useful to identify the extent of the disease process. However, in many situations, a routine MRI may not be specific enough especially if the patient cannot receive contrast intravenously, thereby delaying the appropriate treatment. Diffusion-weighted imaging (DWI) can help in many such situations by providing additional information, accurate characterization and defining the extent of the disease, so that prompt treatment can be initiated. In this article, we illustrate the imaging findings of the spectrum of musculoskeletal infections, emphasizing the role of DWI in this domain. (orig.)

  5. Diffusion weighted MR imaging of transient ischemic attacks

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jin Il; Kim, Dong Ik; Lee, Seung Ik; Yoon, Pyung Ho [Research Institute of Radiological Science, College of Medicine, Yonsei University, Seoul (Korea, Republic of); Heo, Ji Hoe; Lee, Byung In [Medical College, Yonsei University, Seoul (Korea, Republic of)

    2000-07-01

    To investigate the findings of diffusion-weighted MR imaging in patients with transient ischemic attacks (TIA). Between August 1996 and June 1999, 41 TIA patients (M:F =3D 28:13, mean age 57 (range, 27-75) years) with neurologic symptoms lasting less than 24 hours underwent diffusion-weighted MR imaging. The time interval between the onset of symptoms and MR examination was less than one week in 29 patients, from one week to one month in eight, and undetermined in four. Conventional MR and DWI were compared in terms of location of infarction and lesion size (less than 1 cm, 1-3 cm, greater than 3 cm), and we also determined the anatomical vascular territory of acute stroke lesions and possible etiologic mechanisms. The findings of DWI were normal in 24/41 patients (58.5%), while 15 (36.6%) showed acute ischemic lesions. The other two showed old lacunar infarcts. All acute and old DWI lesions were revealed by conventional MR imaging. Among the 15 acute stroke patients, seven had small vessel lacunar disease. In three patients, the infarction was less than 1 cm in size. Six patients showed large vessel infarction in the territory of the MCA, PCA, and PICA; the size of this was less than 1 cm in three patients, 1-3 cm in two, and more than 3 cm in one. In two patients, embolic infarction of cardiac origin in the territory of the MCA and AICA was diagnosed. The possible mechanism of TIA is still undetermined, but acute lesions revealed by DWI in TIA patients tend, in any case, to be small and multiple. (author)

  6. Diffusion weighted MR imaging of transient ischemic attacks

    International Nuclear Information System (INIS)

    Chung, Jin Il; Kim, Dong Ik; Lee, Seung Ik; Yoon, Pyung Ho; Heo, Ji Hoe; Lee, Byung In

    2000-01-01

    To investigate the findings of diffusion-weighted MR imaging in patients with transient ischemic attacks (TIA). Between August 1996 and June 1999, 41 TIA patients (M:F =3D 28:13, mean age 57 (range, 27-75) years) with neurologic symptoms lasting less than 24 hours underwent diffusion-weighted MR imaging. The time interval between the onset of symptoms and MR examination was less than one week in 29 patients, from one week to one month in eight, and undetermined in four. Conventional MR and DWI were compared in terms of location of infarction and lesion size (less than 1 cm, 1-3 cm, greater than 3 cm), and we also determined the anatomical vascular territory of acute stroke lesions and possible etiologic mechanisms. The findings of DWI were normal in 24/41 patients (58.5%), while 15 (36.6%) showed acute ischemic lesions. The other two showed old lacunar infarcts. All acute and old DWI lesions were revealed by conventional MR imaging. Among the 15 acute stroke patients, seven had small vessel lacunar disease. In three patients, the infarction was less than 1 cm in size. Six patients showed large vessel infarction in the territory of the MCA, PCA, and PICA; the size of this was less than 1 cm in three patients, 1-3 cm in two, and more than 3 cm in one. In two patients, embolic infarction of cardiac origin in the territory of the MCA and AICA was diagnosed. The possible mechanism of TIA is still undetermined, but acute lesions revealed by DWI in TIA patients tend, in any case, to be small and multiple. (author)

  7. Clinical usefulness of diffusion-weighted imaging using low and high b-values to detect rectal cancer

    International Nuclear Information System (INIS)

    Hosonuma, Tomonori; Tozaki, Mitsuhiro; Ichiba, Noriatsu; Sakuma, Tohru; Hayashi, Daichi; Yanaga, Katsuhiko; Fukuda, Kunihiko

    2006-01-01

    The purpose of this study was to assess the potential role of diffusion-weighted imaging (DWI) using low and high b-values to detect rectal cancer. The subjects were 15 patients diagnosed endoscopically with rectal cancer (m in 1 patient, sm in 0, mp in 3, ss in 7, se in 1, a in 3) and 20 patients diagnosed endoscopically with colon cancer and no other lesions (control group). Magnetic resonance imaging was performed using a 1.5T system. DWI was performed in the axial plane using echo planar imaging sequence (repetition time/echo time 1200/66, field of view 306 X 350 mm, reconstruction matrix 156 x 256, pixel size 2.0 x 1.4 x 8.0 mm) and acquired with 2 b-values (50 and 800 s/mm 2 ). Low and high b-value DW images were analyzed visually. A lesion was positive by detection of a focal area of high signal in the rectum in high b-value images. The apparent diffusion coefficient (ADC) values of areas of high signal in high b-value images were calculated from the low and high b-value images. High b-value images enabled visualization of all 15 rectal cancers. In the control group, 13 cases were classified as negative and 7 cases as positive for rectal cancer. Sensitivity for detection of rectal cancer was 100% (15/15), and specificity was 65% (13/20). The mean ADC values in 7 patients with false-positive lesions and in 15 patients with rectal cancer were 1.374 x 10 -3 mm 2 /s (standard deviation [SD]: 0.157) and 1.194 x 10 -3 mm 2 /s (SD: 0.152), respectively (P=0.026). DWI with low and high b-values may be used to screen for rectal cancer. (author)

  8. Multispectral diffusion-weighted imaging near metal implants.

    Science.gov (United States)

    Koch, Kevin M; Bhave, Sampada; Gaddipati, Ajeet; Hargreaves, Brian A; Gui, Dawei; Peters, Robert; Bedi, Meena; Mannem, Rajeev; Kaushik, S Sivaram

    2018-02-01

    The need for diffusion-weighted-imaging (DWI) near metallic implants is becoming increasingly relevant for a variety of clinical diagnostic applications. Conventional DWI methods are significantly hindered by metal-induced image artifacts. A novel approach relying on multispectral susceptibility artifact reduction techniques is presented to address this unmet need. DWI near metal implants is achieved through a combination of several advanced MRI acquisition technologies. Previously described approaches to Carr-Purcell-Meiboom-Gill spin-echo train DWI sequences using the periodically rotated overlapping parallel lines with enhanced reconstruction are combined with multispectral-imaging metal artifact reduction principles to provide DWI with substantially reduced artifact levels. The presented methods are applied to limited sets of slices over areas of sarcoma risk near six implanted devices. Using the presented methods, DWI assessment without bulk image distortions is demonstrated in the immediate vicinity of metallic interfaces. In one subject, the apparent diffusion coefficient was reduced in a region of suspected sarcoma directly adjacent to fixation hardware. An initial demonstration of minimal-artifact multispectral DWI in the near vicinity of metallic hardware is described and successfully demonstrated on clinical subjects. Magn Reson Med 79:987-993, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  9. Three-dimensional reconstruction of brain surface anatomy: technique comparison between flash and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Sun Jianzhong; Wang Zhikang; Gong Xiangyang

    2006-01-01

    Objective: To compare two methods 3D flash and diffusion-weighted images (DWI) in reconstructing the brain surface anatomy, and to evaluate their displaying ability, advantages, limitations and clinical application. Methods: Thrity normal cases were prospectively examined with 3D flash sequence and echo-planar DWI. Three-dimensional images were acquired with volume-rendering on workstation. Brain surface structures were evaluated and scored by a group of doctors. Results: Main structures of brain surface were clearly displayed on three-dimensional images based on 3D flash sequence. Average scores were all above 2.50. For images based on DWI, precentral gyrus, postcentral gyrus, superior parietal lobule, superior frontal gyrus, precentral sulcus, central sulcus, postcentral sulcus, intraparietal sulcus and superior frontal sulcus were best shown with average scores between 2.60-2.75, However, supramarginal gyrus, angular gyrus, middle frontal gyrus, inferior frontal gyrus, superior temporal gyrus, lateral sulcus, inferior frontal sulcus could not be well shown, with average scores between 1.67-2.48. Middle temporal gyrus, inferior temporal gyrus, superior temporal sulcus and inferior temporal sulcus can only get scores from 0.88 to 1.27. Scores of images based on 3D flash were much higher than that based on DWI with distinct differentiations, P values were all below 0.01. Conclusion: Three-dimensional images based on 3D flash can really display brain surface structures. It is very useful for anatomic researches. Three-dimensional reconstruction of brain surface based on DWI is a worthy technique to display brain surface anatomy, especially for frontal and parietal structures. (authors)

  10. Diffusion-weighted images of intracranial cyst-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Bergui, M.; Zhong, J.; Sales, S. [Dept. of Neuroradiology, University of Turin (Italy); Bradac, G.B. [Dept. of Neuroradiology, University of Turin (Italy); Neuroradiologia Universitaria, Ospedale S. G. Battista, Turin (Italy)

    2001-10-01

    Magnetic resonance sequences may be designed to evaluate the diffusion movements of the protons (diffusion-weighted images, DWI). In these images, a bright signal identifies a region where the diffusion along a spatial axis is restricted. The contents of a cystic lesion frequently have the signal intensities of a generic homogeneous hyperproteinic fluid (hypointensity in T1-, hyperintensity in T2-weighted images). DWI may give further information about the microscopic organisation of these fluids: a hyperintense signal indicates the presence of a restricted diffusion, due to some kind of microscopic organisation, at the cellular or macromolecular level. This may provide additional information useful for clinical purposes. We obtained DWI in 24 consecutive patients with intracranial cystic lesions, (19 intra-axial: five abscesses, five gliomas, six metastases, two demyelinating lesions, one neurocysticercosis; five extra-axial: two arachnoid cysts, two epidermoid cysts, one cholesteatoma). We found a strongly hyperintense signal, indicating restricted diffusion, in brain abscesses, epidermoid cysts and cholesteatoma; all the remaining lesions were hypointense or mildly hyperintense. We found these data useful in critical diagnoses, such as in differentiating abscesses from tumours, and in identifying elusive tumours such as epidermoid cysts. (orig.)

  11. Diffusion-weighted MR imaging in transient ischaemic attacks

    Energy Technology Data Exchange (ETDEWEB)

    Lamy, C.; Calvet, D.; Domigo, V.; Mas, J. [de l' Hopital Sainte-Anne, Service de Neurologie, Paris Cedex 14 (France); Oppenheim, C.; Naggara, O.; Meder, J.F. [Hoepital Sainte-Anne, Departement d' Imagere Morphologique et Fonchonnille, Paris (France)

    2006-05-15

    The purpose of this study was to determine frequency and the characteristics of diffusion-weighted imaging (DWI) abnormalities in patients with transient ischaemic attack (TIA). We analysed data of 98 consecutive patients (mean age: 60.6{+-}15.4 years, 56 men) admitted between January 2003 and April 2004 for TIA. Age, gender, symptom type and duration, delay from onset to magnetic resonance imaging (MRI), probable or possible TIA and cause of TIA were compared in patients with (DWI+) and without (DWI-) lesions on DWI. Volume and apparent diffusion coefficient (ADC) values of DWI lesions were computed. DWI revealed ischaemic lesions in 34 patients (34.7%). Lesions were small (mean volume: 1.9 cm{sup 3}{+-}3.3), and ADC was moderately decreased (mean ADC ratio: 79.5%). The diagnosis of TIA was considered as probable in all DWI+ patients. A multiple logistic regression model demonstrated that TIA duration greater than or equal to 60 min (OR, 7.6; 95% CI, 2.3-25.7), aphasia (OR, 9.2; 95% CI, 2.7-31.4) and motor deficit (OR, 5.1; 95% CI, 1.5-17.8) were independent predictors of DWI lesions. Prolonged TIA duration, aphasia and motor deficits are associated with DWI lesions. More than half of TIA patients with symptoms lasting more than 60 min have DWI lesions. (orig.)

  12. Diffusion-weighted MR imaging in transient ischaemic attacks

    International Nuclear Information System (INIS)

    Lamy, C.; Calvet, D.; Domigo, V.; Mas, J.; Oppenheim, C.; Naggara, O.; Meder, J.F.

    2006-01-01

    The purpose of this study was to determine frequency and the characteristics of diffusion-weighted imaging (DWI) abnormalities in patients with transient ischaemic attack (TIA). We analysed data of 98 consecutive patients (mean age: 60.6±15.4 years, 56 men) admitted between January 2003 and April 2004 for TIA. Age, gender, symptom type and duration, delay from onset to magnetic resonance imaging (MRI), probable or possible TIA and cause of TIA were compared in patients with (DWI+) and without (DWI-) lesions on DWI. Volume and apparent diffusion coefficient (ADC) values of DWI lesions were computed. DWI revealed ischaemic lesions in 34 patients (34.7%). Lesions were small (mean volume: 1.9 cm 3 ±3.3), and ADC was moderately decreased (mean ADC ratio: 79.5%). The diagnosis of TIA was considered as probable in all DWI+ patients. A multiple logistic regression model demonstrated that TIA duration greater than or equal to 60 min (OR, 7.6; 95% CI, 2.3-25.7), aphasia (OR, 9.2; 95% CI, 2.7-31.4) and motor deficit (OR, 5.1; 95% CI, 1.5-17.8) were independent predictors of DWI lesions. Prolonged TIA duration, aphasia and motor deficits are associated with DWI lesions. More than half of TIA patients with symptoms lasting more than 60 min have DWI lesions. (orig.)

  13. Diffusion-weighted imaging in characterization of cystic pancreatic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sandrasegaran, K., E-mail: ksandras@iupui.edu [Department of Radiology, Indiana University School of Medicine, Indianapolis, IN (United States); Akisik, F.M.; Patel, A.A.; Rydberg, M. [Department of Radiology, Indiana University School of Medicine, Indianapolis, IN (United States); Cramer, H.M.; Agaram, N.P. [Department of Pathology, Indiana University School of Medicine, Indianapolis, IN (United States); Schmidt, C.M. [Department of Surgery, Indiana University School of Medicine, Indianapolis, IN (United States)

    2011-09-15

    Aim: To evaluate whether apparent diffusion coefficient (ADC) measurements from diffusion-weighted imaging (DWI) can characterize or predict the malignant potential of cystic pancreatic lesions. Materials and methods: Retrospective review of the magnetic resonance imaging (MRI) database over a 2-year period revealed 136 patients with cystic pancreatic lesions. Patients with DWI studies and histological confirmation of cystic mass were included. In patients with known pancreatitis, lesions with amylase content of >1000 IU/l that resolved on subsequent scans were included as pseudocysts. ADC of cystic lesions was measured by two independent reviewers. These values were then compared to categorize these lesions as benign or malignant using conventional MRI sequences. Results: Seventy lesions were analysed: adenocarcinoma (n = 4), intraductal papillary mucinous neoplasm (IPMN; n = 28), mucinous cystic neoplasm (MCN; n = 9), serous cystadenoma (n = 16), and pseudocysts (n = 13). There was no difference between ADC values of malignant and non-malignant lesions (p = 0.06), between mucinous and serous tumours (p = 0.12), or between IPMN and MCN (p = 0.42). ADC values for low-grade IPMN were significantly higher than those for high-grade or invasive IPMN (p = 0.03). Conclusion: ADC values may be helpful in deciding the malignant potential of IPMN. However, they are not useful in differentiating malignant from benign lesions or for characterizing cystic pancreatic lesions.

  14. Large deformation diffeomorphic registration of diffusion-weighted images.

    Science.gov (United States)

    Zhang, Pei; Niethammer, Marc; Shen, Dinggang; Yap, Pew-Thian

    2012-01-01

    Registration of Diffusion-weighted imaging (DWI) data emerges as an important topic in magnetic resonance (MR) image analysis. As existing methods are often designed for specific diffusion models, it is difficult to fit to the registered data different models other than the one used for registration. In this paper we describe a diffeomorphic registration algorithm for DWI data in a large deformation setting. Our method generates spatially normalized DWI data and it is thus possible to fit various diffusion models after registration for comparison purposes. Our algorithm includes (1) a reorientation component, where each diffusion profile (DWI signal as a function on a unit sphere) is decomposed, reoriented and recomposed to form the orientation-corrected DWI profile, and (2) a large deformation diffeomorphic registration component to ensure one-to-one mapping in a large-structural-variation scenario. In addition our algorithm uses a geodesic shooting mechanism to avoid the huge computational resources that are needed to register high-dimensional vector-valued data. We also incorporate into our algorithm a multi-kernel strategy where anatomical structures at different scales are considered simultaneously during registration. We demonstrate the efficacy of our method using in vivo data.

  15. Diffusion-weighted imaging in acute bacterial meningitis in infancy

    Energy Technology Data Exchange (ETDEWEB)

    Jan, W.; Zimmerman, R.A.; Bilaniuk, L.T.; Hunter, J.V.; Simon, E.M.; Haselgrove, J. [Department of Radiology, Children' s Hospital of Philadelphia, 34th Street and Civic Center Boulevard, PA 19104, Philadelphia (United States)

    2003-09-01

    Bacterial meningitis is frequently fatal or leads to severe neurological impairment. Complications such as vasculitis, resulting in infarcts, should be anticipated and dealt with promptly. Our aim was to demonstrate the complications of meningitis by diffusion weighted imaging (DWI) in patients who deteriorated despite therapy. We studied 13 infants between the ages of 1 day and 32 months who presented with symptoms ranging from fever and vomiting to seizures, encephalopathy and coma due to bacterial meningitis, performing MRI, including DWI, 2-5 days after presentation. Multiple infarcts were found on DWI in 12 of the 13, most commonly in the frontal lobes (in 10). Global involvement was seen in four children, three of whom died; the fourth had a very poor outcome. In one case abnormalities on DWI were due to subdural empyemas. We diagnosed vasculitis in three of five patients studied with MRA. We think DWI an important part of an MRI study in infants with meningitis. Small cortical or deep white-matter infarcts due to septic vasculitis can lead to tissue damage not easily recognized on routine imaging and DWI can be used to confirm that extra-axial collections represent empyemas. (orig.)

  16. Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report.

    Science.gov (United States)

    Wypych-Klunder, Katarzyna; Adamowicz, Andrzej; Lemanowicz, Adam; Szczęsny, Wojciech; Włodarczyk, Zbigniew; Serafin, Zbigniew

    2014-01-01

    An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p30 ml/min./1.73 m(2) (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR.

  17. Diffusion-weighted imaging of the musculoskeletal system in humans

    International Nuclear Information System (INIS)

    Baur, A.; Reiser, M.F.

    2000-01-01

    This article reviews the principles of diffusion-weighted imaging (DWI) and recent results in DWI of the musculoskeletal system. The potential of DWI in the diagnosis of pathology of the musculoskeletal system is discussed. DWI is a relatively new MR imaging technique that has already been established in neuroradiology, especially in the early detection of brain ischemia. The random motion of water protons on a molecular basis can be measured with DWI. To date DWI of the abdomen and of the musculoskeletal system has only been employed in scientific studies, but first results indicate that it may also be beneficial in these fields. Different diffusion characteristics have been found in normal tissues such as muscle, fat and bone marrow. Also, pathologic entities such as neoplasms, post-therapeutic soft tissue changes and inflammatory processes can be differentiated. Normal muscle shows significantly higher diffusion values than subcutaneous fat and bone marrow, due to a higher mobility of water protons within muscle. Soft tissue tumors exhibit a significantly lower diffusion value compared with post-therapeutic soft tissue changes and inflammatory processes. Necrotic tumor tissue can be distinguished from viable tumor due to significantly higher diffusion of water protons within necrotic tissue. (orig.)

  18. Diffusion-weighted imaging in acute bacterial meningitis in infancy

    International Nuclear Information System (INIS)

    Jan, W.; Zimmerman, R.A.; Bilaniuk, L.T.; Hunter, J.V.; Simon, E.M.; Haselgrove, J.

    2003-01-01

    Bacterial meningitis is frequently fatal or leads to severe neurological impairment. Complications such as vasculitis, resulting in infarcts, should be anticipated and dealt with promptly. Our aim was to demonstrate the complications of meningitis by diffusion weighted imaging (DWI) in patients who deteriorated despite therapy. We studied 13 infants between the ages of 1 day and 32 months who presented with symptoms ranging from fever and vomiting to seizures, encephalopathy and coma due to bacterial meningitis, performing MRI, including DWI, 2-5 days after presentation. Multiple infarcts were found on DWI in 12 of the 13, most commonly in the frontal lobes (in 10). Global involvement was seen in four children, three of whom died; the fourth had a very poor outcome. In one case abnormalities on DWI were due to subdural empyemas. We diagnosed vasculitis in three of five patients studied with MRA. We think DWI an important part of an MRI study in infants with meningitis. Small cortical or deep white-matter infarcts due to septic vasculitis can lead to tissue damage not easily recognized on routine imaging and DWI can be used to confirm that extra-axial collections represent empyemas. (orig.)

  19. Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.

    Science.gov (United States)

    Yoshida, Tsukasa; Urikura, Atsushi; Shirata, Kensei; Nakaya, Yoshihiro; Terashima, Shingo; Hosokawa, Yoichiro

    2016-09-01

    This study aimed to evaluate the image quality and apparent diffusion coefficient (ADC) values of single-shot turbo spin echo (TSE) diffusion-weighted (DW) images obtained using a parallel imaging (PI) technique. All measurements were performed on a 3.0-T whole-body MRI system and 32-channel phased-array coil. Signal-to-noise ratio (SNR) and ADC values were measured with a DW imaging (DWI) phantom comprising granulated sugar and agar. The SNRs were calculated using a subtraction method and compared among TSE-DW images at acceleration factors (AFs) of 1-4. Image blur was visually assessed on TSE-DW images of a pin phantom at AFs of 1-4. The ADC values were calculated using DW images with b = 0 and 1000 s mm(-2). The ADC values of TSE-DW images and echo-planar imaging EPI-DW images were compared. The SNRs decreased as AFs increased, despite selecting the shortest echo time. A lower AF caused increased image blur in the phase-encoding direction. The ADC values of TSE-DWI tended to be lower than those of EPI-DWI, and AFs of 3 and 4 yielded variable ADC values on TSE-DW images. TSE-DWI with an AF of 3 or 4 yielded reduced SNRs; in addition, the image noise and artefacts associated with PI technique may have affected ADC measurements, despite improving image blur in the phase-encoding direction. Optimizing the imaging parameters of TSE-DWI is useful for providing good image quality and accurate ADC measurements.

  20. High signal in bone marrow at diffusion-weighted imaging with body background suppression (DWIBS) in healthy children

    Energy Technology Data Exchange (ETDEWEB)

    Ording Mueller, Lil-Sofie; Avenarius, Derk [University Hospital North Norway, Department of Radiology, Tromsoe (Norway); Olsen, Oeystein E. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom)

    2011-02-15

    In our experience, diffusion-weighted imaging with body background suppression (DWIBS) is hard to interpret in children who commonly have foci of restricted diffusion in their skeletons unrelated to pathology, sometimes in an asymmetrical pattern. This raises serious concern about the accuracy of DWIBS in cancer staging in children. To describe the signal distribution at DWIBS in the normal developing lumbar spine and pelvic skeleton. Forty-two healthy children underwent an MR DWIBS sequence of the abdomen and pelvis. An axial short-tau inversion-recovery (STIR) echo-planar imaging (EPI) pulse sequence was used. Two radiologists did a primary review of the images and based on these preliminary observations, separate scoring systems for the lumbar spine, pelvis and proximal femoral epiphyses/femoral heads were devised. Visual evaluation of the images was then performed by the two radiologists in consensus. The scoring was repeated separately 2 months later by a third radiologist. Restricted diffusion was defined as areas of high signal compared to the background. Coronal maximum intensity projection (MIP) reformats were used to assess the vertebral bodies. For the pelvis, the extension of high signal for each bone was given a score of 0 to 4. Cohen's Kappa interobserver agreement coefficients of signal distribution and asymmetry were calculated. All children had areas of high signal, both within the lumbar vertebral bodies and within the pelvic skeleton. Three patterns of signal distribution were seen in the lumbar spine, but no specific pattern was seen in the pelvis. There was a tendency toward a reduction of relative area of high signal within each bone with age, but also a widespread interindividual variation. Restricted diffusion is a normal finding in the pelvic skeleton and lumbar spine in children with an asymmetrical distribution seen in 48% of normal children in this study. DWIBS should be used with caution for cancer staging in children as this could

  1. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  2. Multimodal MRI in the characterization of glial neoplasms: the combined role of single-voxel MR spectroscopy, diffusion imaging and echo-planar perfusion imaging

    International Nuclear Information System (INIS)

    Zonari, Paolo; Baraldi, Patrizia; Crisi, Girolamo

    2007-01-01

    Diffusion-weighted imaging (DWI), perfusion-weighted imaging (PWI) and MR spectroscopy (MRS) provide useful data for tumor evaluation. To assess the contribution of these multimodal techniques in grading glial neoplasms, we compared the value of DWI, PWI and MRS in the evaluation of histologically proven high- and low-grade gliomas in a population of 105 patients. Independently for each modality, the following variables were used to compare the tumors: minimum apparent diffusion coefficient (ADC) and maximum relative cerebral blood volume (rCBV) normalized values between tumor and healthy tissue, maximum Cho/Cr ratio and minimum NAA/Cr ratio in tumor, and scored lactate and lipid values in tumor. The Mann-Whitney and Wilcoxon tests were employed to compare DWI, PWI and MRS between tumor types. Logistic regression analysis was used to determine which parameters best increased the diagnostic accuracy in terms of sensitivity, specificity, and positive and negative predictive values. ROC curves were determined for parameters with high sensitivity and specificity to identify threshold values to separate high- from low-grade lesions. Statistically significant differences were found for rCBV tumor/normal tissue ratio, and NAA/Cr ratio in tumor and Cho/Cr ratio in tumor between low- and high-grade tumors. The best performing single parameter for group classification was the normalized rCBV value; including all parameters, statistical significance was reached by rCBV tumor/normal tissue ratio, NAA/Cr tumor ratio and lactate. From the ROC curves, a high probability for a neoplasm to be a high-grade lesion was associated with a rCBV tumor/normal tissue ratio of >1.16 and NAA/Cr tumor ratio of <0.44. Combining PWI and MRS with conventional MR imaging increases the accuracy of the attribution of malignancy to glial neoplasms. The best performing parameter was found to be the perfusion level. (orig.)

  3. Multimodal MRI in the characterization of glial neoplasms: the combined role of single-voxel MR spectroscopy, diffusion imaging and echo-planar perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zonari, Paolo [Ospedale ' ' B. Ramazzini' ' , AUSL Modena, Neuroradiologia, Dipartimento Integrato di Neuroscienze, Carpi, Modena (Italy); Baraldi, Patrizia [Universita degli Studi di Modena e Reggio Emilia, Dipartimento di Scienze Biomediche, Sezione di Fisiologia, Modena (Italy); Crisi, Girolamo [Azienda Ospedaliero-Universitaria di Parma, Dipartimento ad Attivita Integrata di Neuroscienze, Parma (Italy)

    2007-10-15

    Diffusion-weighted imaging (DWI), perfusion-weighted imaging (PWI) and MR spectroscopy (MRS) provide useful data for tumor evaluation. To assess the contribution of these multimodal techniques in grading glial neoplasms, we compared the value of DWI, PWI and MRS in the evaluation of histologically proven high- and low-grade gliomas in a population of 105 patients. Independently for each modality, the following variables were used to compare the tumors: minimum apparent diffusion coefficient (ADC) and maximum relative cerebral blood volume (rCBV) normalized values between tumor and healthy tissue, maximum Cho/Cr ratio and minimum NAA/Cr ratio in tumor, and scored lactate and lipid values in tumor. The Mann-Whitney and Wilcoxon tests were employed to compare DWI, PWI and MRS between tumor types. Logistic regression analysis was used to determine which parameters best increased the diagnostic accuracy in terms of sensitivity, specificity, and positive and negative predictive values. ROC curves were determined for parameters with high sensitivity and specificity to identify threshold values to separate high- from low-grade lesions. Statistically significant differences were found for rCBV tumor/normal tissue ratio, and NAA/Cr ratio in tumor and Cho/Cr ratio in tumor between low- and high-grade tumors. The best performing single parameter for group classification was the normalized rCBV value; including all parameters, statistical significance was reached by rCBV tumor/normal tissue ratio, NAA/Cr tumor ratio and lactate. From the ROC curves, a high probability for a neoplasm to be a high-grade lesion was associated with a rCBV tumor/normal tissue ratio of >1.16 and NAA/Cr tumor ratio of <0.44. Combining PWI and MRS with conventional MR imaging increases the accuracy of the attribution of malignancy to glial neoplasms. The best performing parameter was found to be the perfusion level. (orig.)

  4. Repeatability of diffusion-weighted imaging in rectal cancer.

    Science.gov (United States)

    Intven, Martijn; Reerink, Onne; Philippens, Marielle E P

    2014-07-01

    Serial diffusion-weighted MRI (DW-MRI) measurements of the apparent diffusion coefficient (ADC) of rectal tumors are used for rectal cancer response evaluation after neo-adjuvant treatment. In this study, we determined the repeatability of DW-MRI to distinguish therapy-related response from measurement variations. In 18 patients with rectal cancer on five consecutive days, 1.5 Tesla (T) MR imaging was performed including two identical DW-MRI sequences. The repeatability of the tumor ADC measurements and the intraobserver ADC variation were depicted in a Bland-Altman plot. The repeatability coefficient was calculated as the range of ADC values of two identical DWI measurements for 95% of subjects. It was expressed as percentage of the mean ADC value. Three females and 15 males were included. The mean tumor ADC value was 1.15 × 10(-3) mm(2)/s (SD 0.07 × 10(-3) mm(2)). The repeatability coefficient of the ADC value was 9.8% and for the intraobserver repeatability 4.7%. In serial DW-MRI for rectal cancer treatment response evaluation, a repeatability coefficient of 9.8% has to be considered to account for measurement variations in rectal tumor ADC. These variations represent observer judgement and patient and MR spectrometer induced variations. © 2013 Wiley Periodicals, Inc.

  5. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    International Nuclear Information System (INIS)

    Liu, Song; Guan, Wenxian; Wang, Hao; Pan, Liang; Zhou, Zhuping; Yu, Haiping; Liu, Tian; Yang, Xiaofeng; He, Jian; Zhou, Zhengyang

    2014-01-01

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm 2 ). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and Lauren

  6. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Song, E-mail: songliu532909756@gmail.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Guan, Wenxian, E-mail: wenxianguan123@126.com [Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Wang, Hao, E-mail: wanghao20140525@126.com [Department of Gastrointestinal Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Pan, Liang, E-mail: panliang2014@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhuping, E-mail: zhupingzhou@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Yu, Haiping, E-mail: haipingyu2012@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Liu, Tian, E-mail: tianliu2014@126.com [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322 (United States); Yang, Xiaofeng, E-mail: xiaofengyang2014@126.com [Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322 (United States); He, Jian, E-mail: hjxueren@126.com [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China); Zhou, Zhengyang, E-mail: zyzhou@nju.edu.cn [Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008 (China)

    2014-12-15

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm{sup 2}). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and

  7. Diffusion-weighted imaging in the evaluation of watershed hypoxic-ischemic brain injury in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Liu, A.Y.; Zimmerman, R.A.; Haselgrove, J.C.; Bilaniuk, L.T.; Hunter, J.V. [Hospital of the Univ. of Pennsylvania (HUP), Philadelphia (United States). Dept. of Radiology

    2001-11-01

    The purpose of our study was to determine the usefulness of echo-planar diffusion-weighted imaging (EPDI) in the evaluation of watershed hypoxic-ischemic brain injury in pediatric patients. Eighteen patients ranging in age from 3 weeks to 12 years were evaluated for evidence of ischemic/infarction changes on conventional MR and EPDI. Included in the study group were five patients with sickle cell disease, four with congenital heart disease, four with hypotensive episodes with various etiologies, three with sepsis, and two with encephalitis or meningitis. Patients were examined 2 h to 6 days after the initial insult, with follow-up studies in four patients at 1 to 62 days after the initial examination. After conventional MR imaging (T1, FSE T2, and FLAIR), diffusion-weighted MR imaging was performed using high-speed, single-shot EP techniques with TR 6000, TE 144, matrix 96 x 128, FOV 23.3 x 31 and five b values of 0, 160, 360, 640, and 1,000 s/mm{sup 2}. EPDI demonstrated abnormally increased signal in watershed ischemic/infarction zones in all initial cases. Apparent diffusion coefficients (ADC) were obtained in 59 lesions. When compared with radiographically normal (on EPDI) contralateral brain parenchyma, 45 demonstrated a relatively decreased ADC, while eight had normal ({+-} 10 %) and six had increased ADC. In four cases, signal abnormalities on EPDI were not seen or exceeded that seen with conventional MR imaging. In the remaining cases, signal abnormalities were obvious on EPDI and more subtle on conventional MR imaging. Follow-up studies demonstrated resolution of abnormal EPDI signal with persistent abnormalities on conventional imaging in some cases, while others revealed an increase in size or number of EPDI signal abnormalities, suggesting ongoing acute ischemic/infarctive changes. EPDI is a rapid, sensitive technique for detecting watershed ischemic/infarction changes in pediatric patients with hypoperfusion episodes, at times before such changes are

  8. Diffusion-weighted imaging of the pancreas; Diffusionsbildgebung des Pankreas

    Energy Technology Data Exchange (ETDEWEB)

    Gruenberg, K. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie, E010, Heidelberg (Germany); Grenacher, L.; Klauss, M. [Universitaetsklinikum Heidelberg, Abt. Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2011-03-15

    Diffusion-weighted imaging (DWI) has increasingly gained in importance over the last 10 years especially in cancer imaging for differentiation of malignant and benign lesions. Through development of fast magnetic resonance imaging (MRI) sequences DWI is not only applicable in neuroradiology but also in abdominal imaging. As a diagnostic tool of the pancreas DWI enables a differentiation between normal tissue, cancer and chronic pancreatitis. The ADC values (apparent diffusion coefficient, the so-called effective diffusion coefficient) reported in the literature for healthy pancreatic tissue are in the range from 1.49 to 1.9 x 10{sup -3} mm{sup 2}/s, for pancreatic cancer in the range from 1.24 to 1.46 x 10{sup -3} mm{sup 2}/s and for autoimmune pancreatitis an average ADC value of 1.012 x 10{sup -3} mm{sup 2}/s. There are controversial data in the literature concerning the differentiation between chronic pancreatitis and pancreatic cancer. Using DWI-derived IVIM (intravoxel incoherent motion) the parameter f (perfusion fraction) seems to be advantageous but it is important to use several b values. In the literature the mean f value in chronic pancreatitis is around 16%, in pancreatic cancer 8% and in healthy pancreatic tissue around 25%. So far, DWI has not been helpful for differentiating cystic lesions of the pancreas. There are many references with other tumor entities and in animal models which indicate that there is a possible benefit of DWI in monitoring therapy of pancreatic cancer but so far no original work has been published. (orig.) [German] Die Diffusionsbildgebung (''diffusion-weighted imaging'', DWI) gewann in den letzten 10 Jahren insbesondere in der Tumorbildgebung zur Unterscheidung zwischen malignen und benignen Laesionen zunehmend an Bedeutung. Durch Entwicklung schnellerer MR-Sequenzen ist sie nicht nur in der Neuroradiologie, sondern auch in der Abdomenbildgebung einsetzbar. In der Pankreasdiagnostik ermoeglicht sie

  9. Breast cancer detection using double reading of unenhanced MRI including T1-weighted, T2-weighted STIR, and diffusion-weighted imaging: a proof of concept study.

    Science.gov (United States)

    Trimboli, Rubina M; Verardi, Nicola; Cartia, Francesco; Carbonaro, Luca A; Sardanelli, Francesco

    2014-09-01

    The purpose of this study was to investigate the diagnostic performance of unenhanced MRI in detecting breast cancer and to assess the impact of double reading. A total of 116 breasts of 67 women who were 36-89 years old were studied at 1.5 T using an unenhanced protocol including axial T1-weighted gradient-echo, T2-weighted STIR, and echo-planar diffusion-weighted imaging (DWI). Two blinded readers (R1 and R2) independently evaluated unenhanced images using the BIRADS scale. A combination of pathology and negative follow-up served as the reference standard. McNemar and kappa statistics were used. Per-breast cancer prevalence was 37 of 116 (32%): 30 of 37 (81%) invasive ductal carcinoma, five of 37 (13%) ductal carcinoma in situ, and two of 37 (6%) invasive lobular carcinoma. Per-breast sensitivity of unenhanced MRI was 29 of 37 (78%) for R1, 28 of 37 (76%) for R2, and 29 of 37 (78%) for double reading. Specificity was 71 of 79 (90%) for both R1 and R2 and 69 of 79 (87%) for double reading. Double reading did not provide a significant increase in sensitivity. Interobserver agreement was almost perfect (Cohen κ = 0.873). An unenhanced breast MRI protocol composed of T1-weighted gradient echo, T2-weighted STIR, and echo-planar DWI enabled breast cancer detection with sensitivity of 76-78% and specificity of 90% without a gain in sensitivity from double reading.

  10. Clinical study of diffusion weighted imaging in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Chen Yunbin; Mao Yu; Pan Jianji; Hu Chunmiao

    2009-01-01

    Objective: To determine the diagnostic value of diffusion weighted imaging (DWI) for primary nasopharyngeal carcinoma(NPC) and metastatic lymph nodes, and to establish the diagnostic threshold of apparent diffusion coefficients(ADCs). Methods: Conventional MR scans and DWI scans were continuously performed in 56 patients with newly diagnosed NPC and 55 healthy volunteers. All patients received primary tumor biopsy and MR image-guided cervical lymph node fine-needle biopsy. ADC and eADC values of both primary lesions and lymph nodes were calculated and compared. Results: According to the pathological diagnosis, all the 56 patients had non-keratinizing carcinoma and 51 had lymph node metastasis. In the control group, 75 cervical lymph nodes were found. ADC values of both primary NPC and metastatic lymph nodes were significantly lower, while eADC values were higher than those of normal controls. Setting the ADC value threshold at 0.809 x 10 -3 mm 2 /s, the sensitivity and specificity for primary NPC detection were 80.4% and 74.5%, respectively. The negative and positive predictive values were 79.2% and 77.6%, respectively. The accuracy was 78.4%. Setting the ADC value threshold at 0.708 x 10 -3 mm 2 /s, the sensitivity and specificity in the detection of metastatic cervical lymph nodes were 43.1% and 93.3%, respectively. The negative and positive predictive values were 70.7% and 81.5%, respectively. The accuracy was 73.0%. Conclusions: DWI might be a new diagnostic approach in the detection of primary NPC as well as metastatic lymph nodes. (authors)

  11. Diffusion weighted EPI in early cerebral infarction and intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Susumu; Cho, Keiichi; Hosaka, Sumio; Ito, Koichiro; Tajima, Natsuki; Kobayashi, Shiro [Nippon Medical School (Japan). Chiba-Hokuso Hospital; Kumazaki, Tatsuo; Takahashi, Yoshiyuki

    1997-11-01

    Fifteen cases of early cerebral infarction and 14 cases of cerebral hemorrhage underwent diffusion weighted echo planar imaging. Increased intensity area was detected only 2 in 5 cases less than 3 hours from ictus, whereas infarction was correctly diagnosed in all cases over 3 hours. Infarcted area was increased on the follow-up study in 2 cases. Hematoma showed mixed intensity in hyper acute phase, very hypo in acute, mixed in subacute and very hyper in the chronic stage. High intensity area surrounded the hematoma. (author)

  12. Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report

    International Nuclear Information System (INIS)

    Wypych-Klunder, Katarzyna; Adamowicz, Andrzej; Lemanowicz, Adam; Szczęsny, Wojciech; Włodarczyk, Zbigniew; Serafin, Zbigniew

    2014-01-01

    An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p<0.0001). The mean variability of measurements performed in the cortex was significantly lower than that in the medulla (6.2% vs. 11.5%, respectively; p<0.005). The mean SNR was higher in the measurements using b600 than b1000, it was higher in ADC maps than in the eADC maps, and it was higher in the cortex than in the medulla. ADC and eADC measured at b1000 in the cortex were higher in the group of the patients with eGFR ≤30 ml/min./1.73 m 2 as compared to patients with eGFR >30 ml/min./1.73 m 2 (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR

  13. Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Nakamura, Yuko; Higaki, Toru; Akiyama, Yuji; Fukumoto, Wataru; Kajiwara, Kenji; Kaichi, Yoko; Honda, Yukiko; Komoto, Daisuke; Tatsugami, Fuminari; Iida, Makoto; Ohmoto, Toshifumi; Date, Shuji; Awai, Kazuo

    2016-01-01

    To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm 2 ) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm 2 , TE 70 ms; b-value 0 and 600 s/mm 2 , TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm 2 at 1.5T and 3T as “o-1.5T-1000” and “o-3T-1000”. c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm 2 . c-DWI with b = 1000 and 1500 s/mm 2 were defined as “c-1000” and “c-1500”. Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm 2 on 1.5T- and 3T DWIs. Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm 2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm 2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs

  14. Diffusion-weighted MRI of the Prostate: Advantages of Zoomed EPI with Parallel-transmit-accelerated 2D-selective Excitation Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Thierfelder, Kolja M.; Scherr, Michael K.; Weiss, Jakob; Mueller-Lisse, Ullrich G.; Theisen, Daniel [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, Mike; Nikolaou, Konstantin [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Dietrich, Olaf [Ludwig-Maximilians-University Hospital Munich, Josef Lissner Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Munich (Germany); Pfeuffer, Josef [Siemens Healthcare, Application Development, Erlangen (Germany)

    2014-12-15

    The purpose of our study was to evaluate the use of 2D-selective, parallel-transmit excitation magnetic resonance imaging (MRI) for diffusion-weighted echo-planar imaging (pTX-EPI) of the prostate, and to compare it to conventional, single-shot EPI (c-EPI). The MRI examinations of 35 patients were evaluated in this prospective study. PTX-EPI was performed with a TX-acceleration factor of 1.7 and a field of view (FOV) of 150 x 90 mm{sup 2}, whereas c-EPI used a full FOV of 380 x 297 mm{sup 2}. Two readers evaluated three different aspects of image quality on 5-point Likert scales. To quantify distortion artefacts, maximum diameters and prostate volume were determined for both techniques and compared to T2-weighted imaging. The zoomed pTX-EPI was superior to c-EPI with respect to overall image quality (3.39 ± 0.62 vs 2.45 ± 0.67) and anatomic differentiability (3.29 ± 0.65 vs 2.41 ± 0.65), each with p < 0.0001. Artefacts were significantly less severe in pTX-EPI (0.93 ± 0.73 vs 1.49 ± 1.08), p < 0.001. The quantitative analysis yielded a higher agreement of pTX-EPI with T2-weighted imaging than c-EPI with respect to coronal (ICCs: 0.95 vs 0.93) and sagittal (0.86 vs 0.73) diameters as well as prostate volume (0.94 vs 0.92). Apparent diffusion coefficient (ADC) values did not differ significantly between the two techniques (p > 0.05). Zoomed pTX-EPI leads to substantial improvements in diffusion-weighted imaging (DWI) of the prostate with respect to different aspects of image quality and severity of artefacts. (orig.)

  15. In vivo diffusion-weighted imaging of liver tumor necrosis in the VX2 rabbit model at 1.5 Tesla.

    Science.gov (United States)

    Deng, Jie; Rhee, Thomas K; Sato, Kent T; Salem, Riad; Haines, Kenneth; Paunesku, Tatjana; Mulcahy, Mary F; Miller, Frank H; Omary, Reed A; Larson, Andrew C

    2006-04-01

    We sought to demonstrate the feasibility of using single-shot spin-echo echo-planar imaging for imaging liver tumor necrosis in the in vivo VX2 rabbit model at 1.5 T. VX2 liver tumors were grown in 4 rabbits. Diffusion-weighted images (DWIs) were acquired during breath-hold using twice refocused SE-EPI (b = 0, 700, 1400 seconds/mm). Anatomic images for tumor size measurements were acquired using T2W TSE. Rabbits were euthanized for subsequent necropsy. Viable and necrotic tumor tissue ADC measurements were performed with reference to hematoxylin and eosin pathology. A total of 8 tumors were grown with diameters ranging from 1.2 to 5.3 cm. Viable and necrotic tumor compartments were clearly differentiated. Apparent diffusion coefficient in necrotic tumor cores, 1.26 +/- 0.11 x 10 mm/s, were significantly greater than those in surrounding viable tumor tissues, 0.74 +/- 0.06 x 10 mm/s (mean +/- SD, P model is feasible using a 1.5 T clinical magnetic resonance imaging scanner. DWI may permit longitudinal assessment of liver tumor therapies in both preclinical and clinical studies.

  16. Echo planar diffusion and perfusion MRI detect pathophysiological heterogeneity in cerebral contusion

    International Nuclear Information System (INIS)

    Aoyama, Naoki; Mori, Tatsuro; Maeda, Takeshi; Kawamata, Tatsuro; Katayama, Yoichi

    2000-01-01

    Cerebral contusions have heterogeneous mechanisms of early edema formation and frequently cause elevation of ICP and resultant clinical deterioration. In the present study, in order to investigate the mechanisms of early contusion edema, diffusion-weighted imaging, apparent diffusion coefficient (ADC) mapping and perfusion imaging were performed using 1.5 T echo planar imaging (EPI) in patients with cerebral contusion. On diffusion image within 24 hours post-trauma, the central area of the contusion were demonstrated as low intensity. In contrast, the peripheral area had high intensity. The ADC value increased in the central area and decreased in peripheral area. During 24-48 hours post-trauma, a crescent-shaped zone of very high ADC value was observed at the border between these two areas. These results indicate that, in early phase of cerebral contusion, cytotoxic edema is predominantly present in the peripheral area and edema fluid accumulates at the border between central and peripheral area of cerebral contusion 24-48 hours post-trauma. Perfusion imaging demonstrates wide spread CBF depression within the cerebral contusion. Diffusion and perfusion image using EPI are useful for evaluating heterogeneous mechanisms of early edema formation and CBF changes in the acute phase of cerebral contusion. (author)

  17. The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma

    International Nuclear Information System (INIS)

    De Foer, Bert; Bernaerts, Anja; Maes, Joachim; Deckers, Filip; Pouillon, Marc; Vercruysse, Jean-Philippe; Somers, Thomas; Offeciers, Erwin; Michiels, Johan; Casselman, Jan W.

    2007-01-01

    Single-shot (SS) turbo spin-echo (TSE) diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non echo-planar imaging (EPI) technique recently reported for the evaluation of middle ear cholesteatoma. We prospectively evaluated a SS TSE DW sequence in detecting congenital or acquired middle ear cholesteatoma and evaluated the size of middle ear cholesteatoma detectable with this sequence. The aim of this study was not to differentiate between inflammatory tissue and cholesteatoma using SS TSE DW imaging. A group of 21 patients strongly suspected clinically and/or otoscopically of having a middle ear cholesteatoma without any history of prior surgery were evaluated with late post-gadolinium MRI including this SS TSE DW sequence. A total of 21 middle ear cholesteatomas (5 congenital and 16 acquired) were found at surgery with a size varying between 2 and 19 mm. Hyperintense signal on SS TSE DW imaging compatible with cholesteatoma was found in 19 patients. One patient showed no hyperintensity due to autoevacuation of the cholesteatoma sac into the external auditory canal. Another patient showed no hyperintensity because of motion artifacts. This study shows the high sensitivity of this SS TSE DW sequence in detecting small middle ear cholesteatomas, with a size limit as small as 2 mm. (orig.)

  18. Diffusion-weighted MR imaging in biopsy-proven Creutzfeldt-Jakob disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Cheol; Chang, Kee Hyun; Song In Chan; Lee, Sang Hyun; Kwon, Bae Ju; Han, Moon Hee; Kim, Sang Yun [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To compare conventional and diffusion-weighted MR imaging in terms of their depiction of the abnormalities occurring in Creutzfeldt-Jakob disease. We retrospectively analyzed the findings of conventional (T2-weighted and fluid-attenuated inversion recovery) and diffusion-weighted MR imaging in four patients with biopsy-proven Creutzfeldt-Jakob disease. The signal intensity of the lesion was classified by visual assessment as markedly high, slightly high, or isointense, relative to normal brain parenchyma. Both conventional and diffusion-weighted MR images demonstrated bilateral high signal intensity in the basal ganglia in all four patients. Cortical lesions were observed on diffusion-weighted MR images in all four, and on fluidattenuated inversion recovery MR images in one, but in no patient on T2-weighted images. Conventional MR images showed slightly high signal intensity in all lesions, while diffusion-weighted images showed markedly high signal intensity in most. Diffusion-weighted MR imaging is more sensitive than its conventional counterpart in the depiction of Creutzfeldt-Jakob disease, and permits better detection of the lesion in both the cerebral cortices and basal ganglia.

  19. Diffusion-weighted MR imaging in biopsy-proven Creutzfeldt-Jakob disease

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Chang, Kee Hyun; Song In Chan; Lee, Sang Hyun; Kwon, Bae Ju; Han, Moon Hee; Kim, Sang Yun

    2001-01-01

    To compare conventional and diffusion-weighted MR imaging in terms of their depiction of the abnormalities occurring in Creutzfeldt-Jakob disease. We retrospectively analyzed the findings of conventional (T2-weighted and fluid-attenuated inversion recovery) and diffusion-weighted MR imaging in four patients with biopsy-proven Creutzfeldt-Jakob disease. The signal intensity of the lesion was classified by visual assessment as markedly high, slightly high, or isointense, relative to normal brain parenchyma. Both conventional and diffusion-weighted MR images demonstrated bilateral high signal intensity in the basal ganglia in all four patients. Cortical lesions were observed on diffusion-weighted MR images in all four, and on fluidattenuated inversion recovery MR images in one, but in no patient on T2-weighted images. Conventional MR images showed slightly high signal intensity in all lesions, while diffusion-weighted images showed markedly high signal intensity in most. Diffusion-weighted MR imaging is more sensitive than its conventional counterpart in the depiction of Creutzfeldt-Jakob disease, and permits better detection of the lesion in both the cerebral cortices and basal ganglia

  20. Diffusion-Weighted Magnetic Resonance Imaging in Rhombencephalitis due to Listeria monocytogenes

    Energy Technology Data Exchange (ETDEWEB)

    Hatipoglu, H.G.; Onbasioglu Gurbuz, M.; Sakman, B.; Yuksel, E. [Dept. of Radiology, Ankara Numune Education and Research Hospital, Ankara (Turkey)

    2007-04-15

    We present diffusion-weighted imaging findings of a case of rhombencephalitis due to Listeria monocytogenes. It is a rare, life-threatening disorder. The diagnosis is difficult by clinical findings only. In this report, we aim to draw attention to the role of conventional and diffusion-weighted magnetic resonance imaging findings. To our knowledge, this is the first case report in the literature with apparent diffusion coefficient values of diseased brain parenchyma.

  1. Quick Brain Magnetic Resonance Imaging With Diffusion-Weighted Imaging as a First Imaging Modality in Pediatric Stroke.

    Science.gov (United States)

    Christy, Alison; Murchison, Charles; Wilson, Jenny L

    2018-01-01

    Diagnostic delay hinders management of pediatric arterial ischemic stroke. Quick brain MRI with diffusion-weighted imaging sequences may provide a rapid diagnosis without the ionizing radiation of a computed tomography (CT) scan. This was a single center retrospective chart review of children one month to 18 years old with acute arterial ischemic stroke hospitalized between January 2010 and January 2017. We evaluated sensitivity and the time to diagnostic study based on the first imaging study (CT or quick brain MRI with diffusion-weighted imaging). Twenty-five patients were included. Eleven patients (44%) were initially assessed with CT, 10 (40%) with quick brain MRI with diffusion-weighted imaging, and four (16%) with a full MRI. Compared with children undergoing CT, children with quick brain MRI with diffusion-weighted imaging as first study were younger (5.8 versus 14.1 years, P hospitalized at stroke onset (70% versus 18.2%, P = 0.03). Quick brain MRI with diffusion-weighted imaging was more sensitive for ischemia than CT (100% versus 27.3%). The median time from presentation to diagnostic imaging was 4.3 hours, with no differences between CT and quick brain MRI with diffusion-weighted imaging groups, although the quick brain MRI with diffusion-weighted imaging group had a shorter median time from first imaging to diagnostic imaging (P = 0.002). There were no significant missed findings on quick brain MRI with diffusion-weighted imaging. Quick brain MRI with diffusion-weighted imaging was more sensitive than CT for detecting ischemia and may be considered as the first study for some children presenting with suspected arterial ischemic stroke. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Imaging Appearance of Human Immunodeficiency Virus Encephalitis on the Diffusion Weighted Images: A Case Report

    International Nuclear Information System (INIS)

    Lim, Hun Cheol; Yu, In Kyu; Oh, Keon Se

    2011-01-01

    Imaging finding of human immunodeficiency virus (HIV) encephalitis contain bilateral, symmetric, patchy, or diffuse increased T2WI signal intensities in the basal ganglia, cerebellum, brainstem, and centrum semiovale. In particular, the centrum semiovale is most commonly involved. Most of the HIV encephalitis cases are accompanied by brain atrophy. No previous study has reported symmetric increased signal intensity at the bilateral centrum semiovale without brain atrophy on diffusion weighted images in HIV encephalitis patients. Here, we report a case of this. We suggest that radiologists should consider the possibility of HIV encephalitis if there are symmetric increases in signal intensity at the bilateral centrum semiovale on diffusion weighted images of patients with a history of HIV infection.

  3. Malignant versus benign mediastinal lesions: quantitative assessment with diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Guemuestas, Sevtap; Inan, Nagihan; Sarisoy, Hasan Tahsin; Anik, Yonca; Arslan, Arzu; Ciftci, Ercuement; Akansel, Guer; Demirci, Ali

    2011-01-01

    We aimed to evaluate the performance of diffusion-weighted magnetic resonance imaging in differentiating malignant from benign mediastinal lesions. Fifty-three mediastinal lesions were examined with T1- and T2-weighted (W) conventional images. Then, two diffusion-weighted images were obtained with b = 0 and 1000 s/mm 2 values and apparent diffusion coefficients (ADC) were calculated. The statistical significance of differences between measurements was tested using the Student-t test. The mean ADC of malignant lesions was significantly lower than that of the benign masses (p -3 mm 2 /s indicated a malignant lesion with a sensitivity of 95% and specificity of 87%. Diffusion-weighted imaging may be helpful in differentiating benign from malignant mediastinal masses. (orig.)

  4. Malignant versus benign mediastinal lesions: quantitative assessment with diffusion weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guemuestas, Sevtap; Inan, Nagihan; Sarisoy, Hasan Tahsin; Anik, Yonca; Arslan, Arzu; Ciftci, Ercuement; Akansel, Guer; Demirci, Ali [University of Kocaeli, Department of Radiology, School of Medicine, Umuttepe Kocaeli (Turkey)

    2011-11-15

    We aimed to evaluate the performance of diffusion-weighted magnetic resonance imaging in differentiating malignant from benign mediastinal lesions. Fifty-three mediastinal lesions were examined with T1- and T2-weighted (W) conventional images. Then, two diffusion-weighted images were obtained with b = 0 and 1000 s/mm{sup 2} values and apparent diffusion coefficients (ADC) were calculated. The statistical significance of differences between measurements was tested using the Student-t test. The mean ADC of malignant lesions was significantly lower than that of the benign masses (p < 0.001). The cut-off value of {<=} 1.39 x 10{sup -3} mm{sup 2}/s indicated a malignant lesion with a sensitivity of 95% and specificity of 87%. Diffusion-weighted imaging may be helpful in differentiating benign from malignant mediastinal masses. (orig.)

  5. Changes in susceptibility signs on serial T2*-weighted single-shot echo-planar gradient-echo images in acute embolic infarction: comparison with recanalization status on 3D time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kinoshita, Toshibumi; Kinoshita, Fumiko

    2012-01-01

    The present study compares changes in susceptibility signs on follow-up single-shot echo-planar gradient-echo T2*-weighted images (GRE-EPI) with vascular status on follow-up magnetic resonance angiography (MRA) in acute embolic infarction. Twenty consecutive patients with acute embolic infarction repeatedly underwent MR imaging including GRE-EPI and MRA using a 1.5-T MR superconducting system. All patients underwent initial MR examination within 24 h of onset and follow-up MR imaging within 1 month after onset. Changes in susceptibility signs on follow-up GRE-EPI were compatible with vascular status on follow-up MRA in 19 of the 20 patients. Susceptibility signs disappeared with complete recanalization in 13 patients, migrated with partial recanalization in 3, did not change together with the absence of recanalization in 2, and became extended together with the absence of recanalization in 1. Cerebral hemorrhage obscured susceptibility signs in the one remaining patient. Susceptibility signs on follow-up GRE-EPI can reflect changes in an acute embolus, such as recanalization or migration, in this study. Serial GRE-EPI in acute embolism complements the diagnostic certainty of MRA by directly detecting an embolus as a susceptibility sign. (orig.)

  6. A time-efficient acquisition protocol for multipurpose diffusion-weighted microstructural imaging at 7 Tesla.

    Science.gov (United States)

    Sepehrband, Farshid; O'Brien, Kieran; Barth, Markus

    2017-12-01

    Several diffusion-weighted MRI techniques have been developed and validated during the past 2 decades. While offering various neuroanatomical inferences, these techniques differ in their proposed optimal acquisition design, preventing clinicians and researchers benefiting from all potential inference methods, particularly when limited time is available. This study reports an optimal design that enables for a time-efficient diffusion-weighted MRI acquisition scheme at 7 Tesla. The primary audience of this article is the typical end user, interested in diffusion-weighted microstructural imaging at 7 Tesla. We tested b-values in the range of 700 to 3000 s/mm 2 with different number of angular diffusion-encoding samples, against a data-driven "gold standard." The suggested design is a protocol with b-values of 1000 and 2500 s/mm 2 , with 25 and 50 samples, uniformly distributed over two shells. We also report a range of protocols in which the results of fitting microstructural models to the diffusion-weighted data had high correlation with the gold standard. We estimated minimum acquisition requirements that enable diffusion tensor imaging, higher angular resolution diffusion-weighted imaging, neurite orientation dispersion, and density imaging and white matter tract integrity across whole brain with isotropic resolution of 1.8 mm in less than 11 min. Magn Reson Med 78:2170-2184, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Feasibility of diffusion-weighted magnetic resonance imaging in patients with juvenile idiopathic arthritis on 1.0-T open-bore MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barendregt, Anouk M.; Nusman, Charlotte M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Hemke, Robert; Lavini, Cristina; Maas, Mario [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Amiras, Dimitri [Imperial College Healthcare NHS Trust, Radiology Department, St. Mary' s Hospital, Paddington, London (United Kingdom); Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands)

    2015-12-15

    To evaluate the feasibility of non-invasive diffusion-weighted imaging (DWI) of the knee of children with juvenile idiopathic arthritis (JIA) and, further, to analyze the apparent diffusion coefficient (ADC) levels to distinguish synovium from effusion. Standard magnetic resonance imaging of the knee including post-contrast imaging was obtained in eight patients (mean age, 12 years 8 months, five females) using an open-bore magnetic resonance imaging system (1.0 T). In addition, axially acquired echo-planar DWI datasets (b-values 0, 50, and 600) were prospectively obtained and the diffusion images were post-processed into ADC{sub 50-600} maps. Two independent observers selected a region of interest (ROI) for both synovium and effusion using aligned post-contrast images as landmarks. Mann-Whitney U test was performed to compare ADC synovium and ADC effusion. DWI was successfully obtained in all patients. When data of both observers was combined, ADC synovium was lower than ADC effusion in the ROI in seven out of eight patients (median, 1.92 x 10{sup -3} mm{sup 2}/s vs. 2.40 x 10{sup -3} mm{sup 2}/s, p = 0.006, respectively). Similar results were obtained when the two observers were analyzed separately (observer 1: p = 0.006, observer 2: p = 0.04). In this pilot study, on a patient-friendly 1.0-T open-bore MRI, we demonstrated that DWI may potentially be a feasible non-invasive imaging technique in children with JIA. We could differentiate synovium from effusion in seven out of eight patients based on the ADC of synovium and effusion. However, to select synovium and effusion on DWI, post-contrast images were still a necessity. (orig.)

  8. Diagnosis of pericardial cysts using diffusion weighted magnetic resonance imaging: A case series

    Directory of Open Access Journals (Sweden)

    Mousavi Negareh

    2011-09-01

    Full Text Available Abstract Introduction Congenital pericardial cysts are benign lesions that arise from the pericardium during embryonic development. The diagnosis is based on typical imaging features, but atypical locations and signal magnetic resonance imaging sequences make it difficult to exclude other lesions. Diffusion-weighted magnetic resonance imaging is a novel method that can be used to differentiate tissues based on their restriction to proton diffusion. Its use in differentiating pericardial cysts from other pericardial lesions has not yet been described. Case presentation We present three cases (a 51-year-old Caucasian woman, a 66-year-old Caucasian woman and a 77-year-old Caucasian woman with pericardial cysts evaluated with diffusion-weighted imaging using cardiac magnetic resonance imaging. Each lesion demonstrated a high apparent diffusion coefficient similar to that of free water. Conclusion This case series is the first attempt to investigate the utility of diffusion-weighted magnetic resonance imaging in the assessment of pericardial cysts. Diffusion-weighted imaging may be a useful noninvasive diagnostic tool for pericardial cysts when conventional imaging findings are inconclusive.

  9. Imaging of the brain, including diffusion-weighted imaging in methylmalonic acidemia

    Energy Technology Data Exchange (ETDEWEB)

    Michel, Steven J.; Given, Curtis A. [Department of Diagnostic Radiology, University of Kentucky Chandler Medical Center, Room HX-311C, 800 Rose Street, Lexington, KY 40536 (United States); Robertson, William C. [Department of Pediatric Neurology, University of Kentucky Chandler Medical Center, 800 Rose Street, Lexington, KY 40536 (United States)

    2004-07-01

    Methylmalonic acidemia (MMA) is a multifactorial autosomal recessive inborn error of organic acid metabolism, often presenting with neurologic findings. We report the imaging findings in a case of a child with classic neurological and laboratory findings for MMA. Imaging studies demonstrated abnormalities within the basal ganglia, particularly the globi pallidi (GP). Diffusion-weighted abnormalities seen in patients with MMA during an acute episode of metabolic acidosis and at follow-up are discussed. The authors are aware of only one prior report of serial examinations demonstrating resolution of restricted diffusion in the GP. The biochemical and pathophysiologic basis of the imaging findings of MMA are explained. (orig.)

  10. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    International Nuclear Information System (INIS)

    Mürtz, P.; Kaschner, M.; Lakghomi, A.; Gieseke, J.; Willinek, W.A.; Schild, H.H.; Thomas, D.

    2015-01-01

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus

  11. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mürtz, P., E-mail: petra.muertz@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Kaschner, M., E-mail: Marius.Kaschner@med.uni-duesseldorf.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Lakghomi, A., E-mail: Asadeh.Lakghomi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Gieseke, J., E-mail: juergen.gieseke@ukb.uni-bonn.de [Philips Healthcare, Lübeckertordamm 5, 20099 Hamburg (Germany); Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Willinek, W.A., E-mail: winfried.willinek@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Schild, H.H., E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Thomas, D., E-mail: daniel.thomas@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany)

    2015-04-15

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus.

  12. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  13. Evaluation of MR diffusion-weighted imaging in differentiating endometriosis infiltrating the bowel from colorectal carcinoma

    International Nuclear Information System (INIS)

    Busard, M.P.H.; Pieters-van den Bos, I.C.; Mijatovic, V.; Van Kuijk, C.; Bleeker, M.C.G.; Waesberghe, J.H.T.M. van

    2012-01-01

    Objective: Endometriosis infiltrating the bowel may be difficult to differentiate from colorectal carcinoma in cases that present with non-specific clinical and imaging features. The aim of this study is to assess the value of MR diffusion-weighted imaging (DWI) in differentiating endometriosis infiltrating the bowel from colorectal carcinoma. Methods: In 66 patients, MR DWI was added to the standard imaging protocol in patients visiting our outdoor MR clinic for the analysis of suspected or known deep infiltrating endometriosis (DIE). In patients diagnosed with DIE infiltrating the bowel on MR imaging, high b-value diffusion-weighted images were qualitatively assessed by two readers in consensus and compared to high b-value diffusion weighted images in 15 patients evaluated for colorectal carcinoma. In addition, ADC values of lesions were calculated, using b-values of 50, 400 and 800 s/mm 2 . Results: A total of 15 patients were diagnosed with DIE infiltrating the bowel on MR imaging. Endometriosis infiltrating the bowel showed low signal intensity on high b-value diffusion-weighted images in all patients, whereas colorectal carcinoma showed high signal intensity on high b-value diffusion-weighted images in all patients. Mean ADC value in endometriosis infiltrating the bowel (0.80 ± 0.06 × 10 −3 mm 2 /s) was significantly lower compared to mean ADC value in colorectal carcinoma (0.86 ± 0.06 × 10 −3 mm 2 /s), but with considerable overlap between ADC values. Conclusion: Only qualitative assessment of MR DWI may be valuable to facilitate differentiation between endometriosis infiltrating the bowel and colorectal carcinoma.

  14. Clinical single-shot diffusion-weighted MRI of the human brain on a short-bore medium-field imager

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Remonda, L.; Schneider, J.; Goenner, F.; Schroth, G.; Heid, O.

    1999-01-01

    Diffusion-weighted MRI (DWI) is becoming important for assessment of acute stroke. Until recently single-shot DWI required expensive technology such as echo-planar imaging (EPI) available only at some research sites. A new medium-field (1.0 T) short-bore MR imager has been developed with which DWI data sets can be acquired. We prospectively studied 169 patients on this 1.0 T commercial system. After conventional imaging, DWI was performed with a single-shot multi-slice sequence with b values 0 an 900 s/mm 2 , and with the gradients switched in three directions. The apparent diffusion coefficients were calculated with online calculation software. There were 50 patients with totally normal MRI, and 17 had strokes, these strokes were detected as areas of high signal on the images at a maximal b value. There was a drop in the ADC in ischaemic regions: in subacute infarcts, the values were between 0.41 and 0.531 x 10 - 3 mm 2 /s. In old infarcts the ADC was 1.15 x 10 - 3 mm 2 /s. Cerebrospinal fluid (CSF) gave low signal whereas areas in the brain had more intermediate intensities (CSF: 3.00; deep white matter: 0.75, cortical grey matter: 0.80, basal ganglia (thalamus): 0.70 and cerebellar white matter: 0.65 x 10 - 3 mm 2 /s). Anisotropy was detected as areas of restricted diffusion along the tracts. These preliminary data show that DWI can be aquired successfully on a medium-field short-bore system. This should allow the technique to be implemented at more sites, therefore facilitating the diagnosis of acute stroke and rendering early intervention feasible. (orig.)

  15. The role of diffusion-weighted magnetic resonance imaging in the ...

    African Journals Online (AJOL)

    Introduction: The present study indicates that simple and hydatid cysts in liver are a common health problem in Turkey. The aim of the study is to differentiate different types of hydatid cysts from simple cysts by using diffusion-weighted images. Materials and Methods: In total, 37 hydatid cysts and 36 simple cysts in the liver ...

  16. Diffusion-weighted imaging and cognition in the leukoariosis and disability in the elderly study

    DEFF Research Database (Denmark)

    Schmidt, Reinhold; Ropele, Stefan; Ferro, José

    2010-01-01

    BACKGROUND AND PURPOSE: The mechanisms by which leukoariosis impacts on clinical and cognitive functions are not yet fully understood. We hypothesized that ultrastructural abnormalities of the normal-appearing brain tissue (NABT) assessed by diffusion-weighted imaging played a major and independe...

  17. The Fontan circulation and the liver : A magnetic resonance diffusion-weighted imaging study

    NARCIS (Netherlands)

    Wolff, Djoeke; van Melle, Joost P.; Dijkstra, Hildebrand; Bartelds, Beatrijs; Willems, Tineke P.; Hillege, Hans; van den Berg, Aad P.; Ebels, Tjark; Sijens, Paul E.; Berger, Rolf M. F.

    2016-01-01

    Background: Patients with a Fontan circulation tend to develop liver fibrosis, liver cirrhosis and even hepatocellular carcinoma. The aim of this study is to use the magnetic resonance technique diffusing-weighted imaging (DWI) for detecting liver fibrosis/cirrhosis in Fontan patients and to

  18. Tensor Based Representation and Analysis of Diffusion-Weighted Magnetic Resonance Images

    Science.gov (United States)

    Barmpoutis, Angelos

    2009-01-01

    Cartesian tensor bases have been widely used to model spherical functions. In medical imaging, tensors of various orders can approximate the diffusivity function at each voxel of a diffusion-weighted MRI data set. This approximation produces tensor-valued datasets that contain information about the underlying local structure of the scanned tissue.…

  19. The Role of Diffusion-Weighted Magnetic Resonance Imaging in the ...

    African Journals Online (AJOL)

    2018-02-23

    Feb 23, 2018 ... How to cite this article: Aksoy S, Erdil I, Hocaoglu E, Inci E, Adas GT,. Kemik O, et al. The Role of Diffusion-Weighted Magnetic Resonance. Imaging in the Differential Diagnosis of Simple and Hydatid Cysts of the. Liver. Niger J Clin Pract 2018;21:212-6. This is an open access article distributed under the ...

  20. Super-resolution reconstruction of diffusion parameters from diffusion-weighted images with different slice orientations.

    Science.gov (United States)

    Van Steenkiste, Gwendolyn; Jeurissen, Ben; Veraart, Jelle; den Dekker, Arnold J; Parizel, Paul M; Poot, Dirk H J; Sijbers, Jan

    2016-01-01

    Diffusion MRI is hampered by long acquisition times, low spatial resolution, and a low signal-to-noise ratio. Recently, methods have been proposed to improve the trade-off between spatial resolution, signal-to-noise ratio, and acquisition time of diffusion-weighted images via super-resolution reconstruction (SRR) techniques. However, during the reconstruction, these SRR methods neglect the q-space relation between the different diffusion-weighted images. An SRR method that includes a diffusion model and directly reconstructs high resolution diffusion parameters from a set of low resolution diffusion-weighted images was proposed. Our method allows an arbitrary combination of diffusion gradient directions and slice orientations for the low resolution diffusion-weighted images, optimally samples the q- and k-space, and performs motion correction with b-matrix rotation. Experiments with synthetic data and in vivo human brain data show an increase of spatial resolution of the diffusion parameters, while preserving a high signal-to-noise ratio and low scan time. Moreover, the proposed SRR method outperforms the previous methods in terms of the root-mean-square error. The proposed SRR method substantially increases the spatial resolution of MRI that can be obtained in a clinically feasible scan time. © 2015 Wiley Periodicals, Inc.

  1. Cerebral Effects of Targeted Temperature Management Methods Assessed by Diffusion-Weighted Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Grejs, Anders Morten; Gjedsted, Jakob; Pedersen, Michael

    2016-01-01

    The aim of this randomized porcine study was to compare surface targeted temperature management (TTM) to endovascular TTM evaluated by cerebral diffusion-weighted magnetic resonance imaging (MRI): apparent diffusion coefficient (ADC), and by intracerebral/intramuscular microdialysis. It is well...

  2. The Role of Diffusion-Weighted Magnetic Resonance Imaging in the ...

    African Journals Online (AJOL)

    2018-02-23

    Feb 23, 2018 ... All patients were examined by a. 1.5-T MR system (Siemens and Magnetom Avanto) with phased-array bodycoils. Axial diffusion-weighted images were performed with a 1.5 T body scanner (Avanto;. Siemens, Erlangen, Germany) using an 18-channel phased-array body coil: T1-weighted (axial turbo spin-.

  3. Wallenberg's lateral medullary syndrome: diffusion-weighted imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kitis, O.; Calli, C.; Yunten, N.; Kocaman, A.; Sirin, H. [Ege Univ., Izmir (Turkey). Dept. of Radiology

    2004-02-01

    To investigate the efficacy of diffusion-weighted imaging in patients with Wallenberg's lateral medullary syndrome. Thirteen patients with Wallenberg's lateral medullary syndrome were examined with conventional and echoplanar diffusion-weighted magnetic resonance (MR) imaging in a 1.5 T magnetic resonance unit. MR examinations were obtained in the acute or subacute stage of clinical syndrome, and diffusion-weighted imaging (DWI) was considered to be positive for infarction when an increase in signal was seen on b = 1000 s/mm2 images in the posterolateral medullary localization. DWIs were positive in 12 patients in the acute or subacute stages of this clinical syndrome. A false-negative result was obtained in only one patient examined within the first day, 10 h after onset of the symptoms. In the visual evaluation of the DWI, the contrast between normal and infarcted brainstem area was better in the high b-value images than in the apparent diffusion coefficient map images. DWI is a valuable technique for examining patients presenting with the signs and symptoms of Wallenberg's syndrome and high b-value images can provide complementary data to T2-weighted images. However, because most of our case group were in either the acute or subacute stage, true sensitivity of the method in the hyperacute stage of the syndrome remains unclear.

  4. Fat-saturated diffusion-weighted imaging with three-dimensional MP-RAGE sequence

    International Nuclear Information System (INIS)

    Numano, Tomokazu; Homma, Kazuhiro; Takahashi, Nobuyuki; Hirose, Takeshi

    2005-01-01

    Image misrepresentation due to chemical shifts can create image artifacts on MR images. Distinguishing the organization and affected area can be difficult due to the chemical shift artifacts. Chemical shift selective (CHESS) is a method of decreasing chemical shift artifacts. In this study we have developed a new sequence for fat-saturated three-dimensional diffusion weighted MR imaging. This imaging was done during in vivo studies using an animal experiment MR imaging system at 2.0 T. In this sequence a preparation phase with a ''CHESS-90 deg RF-Motion Proving Gradient (MPG-180 deg RF-MPG-90 deg RF pulse train) was used to sensitize the magnetization to fat-saturated diffusion. Centric k-space acquisition order is necessary to minimize saturation effects from tissues with short relaxation times. From experimental results obtained with a phantom, the effect of the diffusion weighting and the effect of the fat-saturation were confirmed. From rat experimental results, fat-saturated diffusion weighted image data (0.55 x 0.55 x 0.55 mm 3 : voxel size) were obtained. This sequence was useful for in vivo imaging. (author)

  5. Diffusion-weighted MR imaging of cystic lesions of neurocysticercosis: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Raffin, Luciana S.; Bacheschi, Luiz A.; Machado, Luis R.; Nobrega, Jose P.S.; Coelho, Christina; Leite, Claudia C. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina. Dept. de Neurologia]. E-mail: bacheschi@henet.usp.br

    2001-12-01

    Neurocysticercosis is an endemic disease in some developing countries. It has pleomorfic clinical and imaging findings, which are variable from patient to patient. In this preliminary note, we studied the magnetic resonance diffusion-weighted images of sixteen patients presenting with cystic lesions of this disease diagnosed by clinical and laboratorial findings. All the lesions had hypointense signal and the similar apparent diffusion coefficient values as the cerebrospinal fluid. (author)

  6. Diffusion-weighted MR imaging of cystic lesions of neurocysticercosis: a preliminary study

    International Nuclear Information System (INIS)

    Raffin, Luciana S.; Bacheschi, Luiz A.; Machado, Luis R.; Nobrega, Jose P.S.; Coelho, Christina; Leite, Claudia C.

    2001-01-01

    Neurocysticercosis is an endemic disease in some developing countries. It has pleomorfic clinical and imaging findings, which are variable from patient to patient. In this preliminary note, we studied the magnetic resonance diffusion-weighted images of sixteen patients presenting with cystic lesions of this disease diagnosed by clinical and laboratorial findings. All the lesions had hypointense signal and the similar apparent diffusion coefficient values as the cerebrospinal fluid. (author)

  7. A Novel Multivoxel-Based Quantitation of Metabolites and Lipids Noninvasively Combined with Diffusion-Weighted Imaging in Breast Cancer

    Science.gov (United States)

    2012-09-01

    invasive lobular cancer), twenty patients with benign breast tumor ( fibroadenoma , proliferative fibrocystic change and papillomas) will be...Metabolites and Lipids Noninvasively Combined with Diffusion-Weighted Imaging in Breast Cancer PRINCIPAL INVESTIGATOR: Michael Albert Thomas...5a. CONTRACT NUMBER Noninvasively Combined with Diffusion-Weighted Imaging in Breast Cancer 5b. GRANT NUMBER W81XWH-10-1-0743 5c. PROGRAM

  8. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  9. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  10. PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) and EPI diffusion-weighted MR imaging at 3.0 T: pontine magnetic susceptibility artifacts depend on pneumatization of the sphenoid sinus

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Chul Ho; Kim, In Soo [College of Medicine, Keimyung University, Daegu (Korea, Republic of)

    2006-10-15

    In the case of well pneumatized sphenoid sinus, magnetic susceptibility artifact can be visualized at the brainstem and especially at the pons on echo-planar imaging (EPI) diffusion-weighted imaging. Fast spin-echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) is a novel imaging method that can reduce these artifacts. In 3.0 T MR, we first evaluate the degree of the relationship of pneumatization of the sphenoid sinus with the occurrence of magnetic susceptibility artifacts (MSA) on the echo planar imaging (EPI) diffusion-weighted imaging (DWI), and we evaluated using PROPELLER-DWI for cancellation of MSAs of the pons in the patients who had MSAs on the EPI-DWI. Sixty subjects (mean age: 58 years old and there were 30 men) who were classified according to the two types of sphenoid sinus underwent EPI-DWI. The two types of sphenoid sinus were classified by the degree of pneumatization on the sagittal T2-weighted image. The type-1 sphenoid sinus was 0% to less than 50% aeration of the bony sellar floor, and type-2 was 50% or more aeration of the boney sellar floor. Each of 10 subjects (n = 20/60, mean age: 53) of the two types had PROPELLER and EPI-DWI performed simultaneously. We first evaluated the absence or presence of MSAs at the pons in the two types, and we compared EPI and PROPELLER-DWI in the subjects who underwent the two MR sequences simultaneously. We used 3.0 T MR (Signa VHi, GE, MW, U.S.A.) with a standard head coil. All the MR images were interpreted by one neuroradiologiest. For the type-1, two (6.7%) cases had MSAs and 28 (93.7%) cases did not have MSAs on the EPI-DWI. For the type-2, twenty-seven (90%) cases had MSAs and 3 (10%) cases did not have MSAs on the EPI-DWI. The degree of pneumatization of the sphenoid sinus was related with the occurrence of MSAs of the pons, according to the chi-square test ({rho} = 0.000). All twenty cases who had PROPELLER-DWI performed had no MASs at the pons regardless of

  11. Diffusion-weighted imaging and cognition in the leukoariosis and disability in the elderly study

    DEFF Research Database (Denmark)

    Schmidt, Reinhold; Ropele, Stefan; Ferro, José

    2010-01-01

    BACKGROUND AND PURPOSE: The mechanisms by which leukoariosis impacts on clinical and cognitive functions are not yet fully understood. We hypothesized that ultrastructural abnormalities of the normal-appearing brain tissue (NABT) assessed by diffusion-weighted imaging played a major and independent...... role. METHODS: In addition to a comprehensive clinical, neuropsychologic, and imaging work-up, diffusion-weighted imaging was performed in 340 participants of the multicenter leukoariosis and disability study examining the impact of white matter hyperintensities (WMH) on 65- to 85-year old individuals...... without previous disability. WMH severity was rated according to the Fazekas score. Multivariate regression analysis served to assess correlations of histogram metrics of the apparent diffusion coefficient (ADC) of whole-brain tissue, NABT, and of the mean ADC of WMH with cognitive functions. RESULTS...

  12. The diagnostic value of diffusion-weighted magnetic resonance imaging in soft tissue abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Ozkan; Koparan, Halil Ibrahim [Yuezuencue Yil University, Department of Radiology, Van (Turkey); Avcu, Serhat, E-mail: serhatavcu@hotmail.com [Yuezuencue Yil University, Department of Radiology, Van (Turkey); Kalender, Ali Murat [Yuezuencue Yil University, Department of Orthopaedics, General Surgery, Van (Turkey); Kisli, Erol [Yuezuencue Yil University, Department of General Surgery, Van (Turkey)

    2011-03-15

    Purpose: To study the diagnostic value of diffusion-weighted imaging (DWI) in soft tissue abscesses. Materials and methods: Fifty patients were included in this study who were thought to have soft tissue abscess or cystic lesion as a result of clinical and radiological examinations. Localisations of the lesions were: 1 periorbital, 3 breast, 14 intraabdominal, and 32 intramuscular lesions. After other radiological examinations, DWI was performed. The signal intensity values of the lesions were evaluated qualitatively according to the hyperintensity on b-1000 DWI, using 1.5 T MR system. All of the lesions were aspirated after DWI, and detection of pus in the aspiration material was accepted as gold standard for the diagnosis of abscess. Results: In 38 of the 50 patients, hyperintensity was obtained on diffusion-weighted images. False-positive results were maintained in 2 of these patients, and true-positive results were maintained in 36 of them. In 11 of the 50 patients, hypointensity was visualised on diffusion-weighted images. False-negative results were maintained in 3 of these patients, and true-negative results were maintained in 8 of them. An abscess which was seen on post-contrast conventional MRI could not be seen on DWI, and this was regarded as false-negative. Conclusion: The sensitivity and specificity of diffusion-weighted images for detecting soft tissue abscesses were found to be 92% and 80%, respectively. DWI has a high diagnostic value in soft tissue abscesses, and is an important imaging modality that may be used for the differentiation of cysts and abscesses.

  13. Prenatal MR diffusion-weighted imaging in a fetus with hemimegalencephaly

    Energy Technology Data Exchange (ETDEWEB)

    Agid, Ronit; Lieberman, Sivan; Gomori, John M. [Hadassah University Hospital, Division of Neuroradiology, Department of Radiology, Kiryat Hadassah, Ein-Karem, P.O. Box 12000, Jerusalem (Israel); Nadjari, Michael [Hadassah University Hospital, Department of Obstetrics and Gynecology, Jerusalem (Israel)

    2006-02-01

    We report a case of hemimegalencephaly diagnosed by prenatal MRI with an emphasis on its appearance on diffusion-weighted images. This case shows that in this condition the enlarged hemisphere may show restricted diffusion on prenatal MRI. In our opinion, this finding may result from a combination of increased cellularity and advanced myelination in the affected hemisphere. Restricted diffusion is an additional valuable indicator in the analysis of the fetal brain. (orig.)

  14. Giant Vertebral Notochordal Rest: Magnetic Resonance and Diffusion Weighted Imaging Findings

    International Nuclear Information System (INIS)

    Oner, Ali Yusuf; Akpek, Sergin; Tali, Turgut; Ucar, Murat

    2009-01-01

    A giant vertebral notochordal rest is a newly described, benign entity that is easily confused with a vertebral chordoma. As microscopic notochordal rests are rarely found in adult autopsies, the finding of a macroscopic vertebral lesion is a new entity with only seven previously presented cases. We report here radiological findings, including diffusion weighted images, of a patient with a giant notochordal remnant confined to the L5 vertebra, with an emphasis on its distinction from a chordoma

  15. Early diagnosis and severity assessment of acute pancreatitis (AP) using MR elastography (MRE) with spin-echo echo-planar imaging.

    Science.gov (United States)

    Shi, Yu; Liu, Ying; Liu, Yan-Qing; Gao, Feng; Li, Jia-Hui; Li, Qiu-Ju; Guo, Qi-Yong

    2017-11-01

    To evaluate the accuracy of magnetic resonance elastography (MRE) in comparison to contrast-enhanced computed tomography (CE-CT) for early diagnosis and prediction of severity in acute pancreatitis (AP). This cross-sectional prospective study included 76 patients with suspected AP who underwent both CE-CT and 3.0T MRE within 24 hours of hospital admission. Pancreatic stiffness, CT severity index (CTSI), Acute Physiology and Chronic Health Evaluation (APACHE)-II, and Bedside Index for Severity in AP (BISAP) scores were comparatively evaluated using data from the first 24 hours of admission, and diagnosis and severity of AP were confirmed according to the revised Atlanta Classification (2012). The accuracy of MRE for predicting disease severity was compared with that of CE-CT and the clinical scoring systems using area under the receiver-operating curve (AUC) analysis. AP was confirmed in 56/76 patients (73.7%). Pancreatic stiffness values of >1.47 kPa showed significantly better diagnostic performance than CE-CT (AUC: 0.993 vs. 0.818, P AP. The accuracy of pancreatic stiffness >2.47 kPa was comparable to that of the CTSI, APACHE-II and BISAP scores for predicting severe AP (accuracy = 85.5%, 75.0%, 88.2%, and 78.9%, respectively). The pairwise comparisons were not significant after Bonferroni correction (P AP. We recommend MRE at hospital admission for initial evaluation of AP. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1311-1319. © 2017 International Society for Magnetic Resonance in Medicine.

  16. Diffusion-weighted imaging of tumor recurrencies and posttherapeutical soft-tissue changes in humans

    International Nuclear Information System (INIS)

    Baur, A.; Huber, A.; Reiser, M.; Arbogast, S.; Duerr, H.R.; Zysk, S.; Wendtner, C.; Deimling, M.

    2001-01-01

    The aim of this study was to examine soft tissue tumor recurrences and posttherapeutic soft tissue changes in humans with a diffusion-weighted steady-state free precession (SSFP) sequence. Twenty-four patients with 29 pathologies of the pelvis or the extremities were examined. The lesions were classified as follows: group 1, recurrent viable tumors (n = 10); group 2, postoperative hygromas (n = 7); and group 3, posttherapeutic reactive inflammatory muscle changes (n = 12). The sequence protocol in these patients consisted of short tau inversion recovery images, T2-weighted spin-echo (SE), pre- and postcontrast T1-weighted SE images and the diffusion-weighted SSFP sequence. The signal loss on diffusion-weighting was evaluated visually on a four-grade scale and quantitatively. The signal intensities were measured in regions of interest and a regression analysis was performed. Statistical analyses was performed utilizing the Student's t-test. The signal loss was significantly higher for hygromas and edematous muscle changes than for recurrent tumors (p < 0.001) indicating higher diffusion of water protons. The regression coefficient was -0.11 (mean) for tumors. Hygromas had a significantly higher signal loss than inflammatory edematous muscle changes (p < 0.01). The regression coefficients were -0.29 (mean) for hygromas and -0.22 (mean) for edematous muscle changes. The SSFP sequence seems to be a suitable method for diffusion-weighted imaging of the musculoskeletal system in humans. These preliminary results suggest that the signal loss and the regression coefficients can be used to characterize different types of tissue. (orig.)

  17. Diffusion weighted imaging of female pelvic cancers: Concepts and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, Shonit, E-mail: shonit.punwani@gmail.com [Department of Academic Radiology, 2nd Floor Podium, University College London Hospital, 235 Euston Road, London NW1 2BU (United Kingdom)

    2011-04-15

    Early applications of diffusion weighted magnetic resonance imaging (DWI) were limited to neuroimaging, concentrating either on stroke or brain tumours. With recent advances in MRI hardware and software DWI is now increasingly being investigated for cancer assessment throughout the body. Clinical applications of DWI relating to female pelvic cancers have largely concentrated on detection, localisation and staging of disease. More recently investigators have started to evaluate the ability of DWI for determining tumour histology and even predicting the outcome of chemoradiation treatment. This article reviews the physical concepts of MR diffusion weighting, illustrates the biophysical basis of diffusion contrast and reports the clinical applications of DWI for cervical, endometrial, ovarian, rectal and bladder tumours.

  18. Diffusion-weighted MR images and pineoblastoma. Diagnosis and follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Gasparetto, Emerson L.; Cruz Junior, L. Celso Hygino; Doring, Thomas M.; Domingues, Romeu C. [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)]. E-mail: egasparetto@gmail.com; Araujo, Bertha; Dantas, Mario Alberto [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. of Radiology; Chimelli, Leila [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina. Dept. of Pathology

    2008-07-01

    Pineoblastomas are uncommon pineal tumors, which demonstrate rapid growing and poor prognosis. We report the case of a 43-year-old man with an enhancing pineal region mass, which showed restriction of the diffusion on diffusion-weighted (DW) MR images. The surgical biopsy defined the diagnosis of pineoblastoma and the therapy was initiated with radiation and chemotherapy. Three months later, the follow-up MR imaging showed areas suggestive of necrosis and the DW images demonstrate no significant areas of restricted diffusion. The differential diagnosis of pineal region masses that could show restriction of diffusion is discussed. (author)

  19. Diffusion-weighted MR imaging findings in a patient with herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Heiner, L.; Demaerel, Ph.

    2003-01-01

    Introduction: Herpes simplex meningoencephalitis is one of the most common viral central nervous system infection in adults. Early diagnosis is essential for treatment. Case report: We present a case of a 68-year-old female patient with herpes simplex infection. On admission, she was in severe clinical condition. Diffusion-weighted (DW) magnetic resonance imaging detected brain involvement better than conventional sequences. After acyclovir therapy, the patient fully recovered. Conclusion: DW magnetic resonance imaging is expected to provide a more sensitive imaging in herpes simplex patients than conventional sequences

  20. Diffusion-weighted MR images and pineoblastoma. Diagnosis and follow-up

    International Nuclear Information System (INIS)

    Gasparetto, Emerson L.; Cruz Junior, L. Celso Hygino; Doring, Thomas M.; Domingues, Romeu C.; Araujo, Bertha; Dantas, Mario Alberto; Chimelli, Leila

    2008-01-01

    Pineoblastomas are uncommon pineal tumors, which demonstrate rapid growing and poor prognosis. We report the case of a 43-year-old man with an enhancing pineal region mass, which showed restriction of the diffusion on diffusion-weighted (DW) MR images. The surgical biopsy defined the diagnosis of pineoblastoma and the therapy was initiated with radiation and chemotherapy. Three months later, the follow-up MR imaging showed areas suggestive of necrosis and the DW images demonstrate no significant areas of restricted diffusion. The differential diagnosis of pineal region masses that could show restriction of diffusion is discussed. (author)

  1. Diffusion-weighted MR imaging of kidneys in renal artery stenosis

    International Nuclear Information System (INIS)

    Yildirim, Erkan; Kirbas, Ismail; Teksam, Mehmet; Karadeli, Elif; Gullu, Hakan; Ozer, Ismail

    2008-01-01

    Objective: The purpose of our study was to evaluate perfusion and diffusion of kidneys in renal artery stenosis (RAS) and any correlation between stenosis and ADC values and whether this imaging modality may be a noninvasive complementary assessment technique to MR angiography before interventional procedures. Materials and methods: Twenty consecutive patients suspected of having renal artery stenosis were evaluated with renal MR angiography to exclude stenosis and were then included in the study. Transverse DW multisection echo-planar MR imaging was performed. In the transverse ADC map, rectangular regions of interest were placed in the cortex on 3 parts (upper, middle, and lower poles) in each kidney. ADCs of the kidneys were calculated separately for the low, average, and high b-values to enable differentiation of the relative influence of the perfusion fraction and true diffusion. The ADC values of 39 kidneys (13 with renal artery stenosis and 26 normal renal arteries) were compared, and the relationship between stenosis degree and ADC values was calculated. Results: RAS was detected in 11 of 20 (55%) patients with MRA. Thirteen of 39 kidneys demonstrated RAS, and 26 were normal. The ADC low (1.9 ± 0.2 versus 2.1 ± 0.2; P = .020), ADC average (1.7 ± 0.2 versus 1.9 ± 0.1; P = .006), and ADC high (1.8 ± 0.2 versus 2.0 ± 0.1; P = .012) values were significantly lower in patients with kidneys with arterial stenosis than that in patients with kidneys with normal arteries. Statistical analysis revealed that stenosis degree correlated strongly with ADC low (r = -.819; P = .001), ADC average (r = -.754; P = .003), and ADC high (r = -.788; P = .001). The ADC low , ADC average , and ADC high values were significantly lower in patients with kidneys with arterial stenosis than that in patients with kidneys with normal arteries. Conclusion: We think that DW MR imaging of kidneys with RAS can help determine the functional status of a renal artery stenosis

  2. Diffusion-Weighted Imaging Using a Readout-Segmented, Multishot EPI Sequence at 3 T Distinguishes between Morphologically Differentiated and Undifferentiated Subtypes of Thyroid Carcinoma—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Stefan Schob

    2016-10-01

    Full Text Available BACKGROUND: Thyroid carcinomas represent the most frequent endocrine malignancies. Recent studies were able to distinguish malignant from benign nodules of the thyroid gland with diffusion-weighted imaging (DWI. Although this differentiation is undoubtedly helpful, presurgical discrimination between well-differentiated and undifferentiated carcinomas would be crucial to define the optimal treatment algorithm. Therefore, the aim of this study was to investigate if readout-segmented multishot echo planar DWI is able to differentiate between differentiated and undifferentiated subtypes of thyroid carcinomas. PATIENTS AND METHODS: Fourteen patients with different types of thyroid carcinomas who received preoperative DWI were included in our study. In all lesions, apparent diffusion coefficient (ADCmin, ADCmean, ADCmax, and D were estimated on the basis of region of interest measurements after coregistration with T1-weighted, postcontrast images. All tumors were resected and analyzed histopathologically. Ki-67 index, p53 synthesis, cellularity, and total and average nucleic areas were estimated using ImageJ version 1.48. RESULTS: Analysis of variance revealed a statistically significant difference in ADCmean values between differentiated and undifferentiated thyroid carcinomas (P = .022. Spearman Rho calculation identified significant correlations between ADCmax and cell count (r = 0.541, P = .046 as well as between ADCmax and total nuclei area (r = 0.605, P = .022. CONCLUSION: DWI can distinguish between differentiated and undifferentiated thyroid carcinomas.

  3. Comparison of stroke infarction between CT perfusion and diffusion weighted imaging: preliminary results

    Science.gov (United States)

    Abd. Rahni, Ashrani Aizzuddin; Arka, Israna Hossain; Chellappan, Kalaivani; Mukari, Shahizon Azura; Law, Zhe Kang; Sahathevan, Ramesh

    2016-03-01

    In this paper we present preliminary results of comparison of automatic segmentations of the infarct core, between that obtained from CT perfusion (based on time to peak parameter) and diffusion weighted imaging (DWI). For each patient, the two imaging volumes were automatically co-registered to a common frame of reference based on an acquired CT angiography image. The accuracy of image registration is measured by the overlap of the segmented brain from both images (CT perfusion and DWI), measured within their common field of view. Due to the limitations of the study, DWI was acquired as a follow up scan up to a week after initial CT based imaging. However, we found significant overlap of the segmented brain (Jaccard indices of approximately 0.8) and the percentage of infarcted brain tissue from the two modalities were still fairly highly correlated (correlation coefficient of approximately 0.9). The results are promising with more data needed in future for clinical inference.

  4. Diffusion-weighted MR imaging in the early diagnosis of periventricular leukomalacia

    International Nuclear Information System (INIS)

    Bozzao, Alessandro; Di Paolo, Ambrogio; Simonetti, Alessandra; Mazzoleni, Clarissa; Fasoli, Fabrizio; Floris, Roberto; Fantozzi, Luigi Maria

    2003-01-01

    Diffusion-weighted imaging (DWI) has been shown to be highly sensitive in detecting acute cerebral infarction, but its use in detecting hypoxic-ischemic encephalopathy (HIE) in neonates is still controversial. Moreover, few reports concern pre-term infants with possible periventricular leukomalacia (PVL). We examined the ability of this technique to detect cerebral changes in the acute phase of PVL. Fifteen MR examinations were performed in 11 pre-term infants (mean age 3.4 days, range 2-6 days). Conventional DWI sequences, apparent diffusion coefficient (ADC) maps, and US obtained in the acute phase were compared. All the neonates underwent US follow-up up to 4 months after delivery; those with suspected PVL also underwent MRI follow-up for up to 2 months. Qualitative and quantitative evaluations were performed to assess the presence of DW changes compatible with PVL. Diffusion-weighted MRI showed signal hyperintensity associated with decreased ADC values in 3 subjects (27%). In these patients conventional MRI sequences were interpreted as normal and US (performed at the same time) as doubtful in 2 and compatible with PVL in 1 subject. The MRI and US follow-up confirmed severe damage in all these patients. In 1 neonate hemorrhages involving the germinative matrix were identified. In 8 neonates MRI was considered normal. In these subjects US follow-up (up to 4 months) confirmed no signs of PVL. Diffusion-weighted imaging may have a higher correlation with later evidence of PVL than does conventional MR imaging and US when performed in the acute phase of the disease. (orig.)

  5. Quantitative Analysis of Diffusion Weighted MR Images of Brain Tumor Using Signal Intensity Gradient Technique

    Directory of Open Access Journals (Sweden)

    S. S. Shanbhag

    2014-01-01

    Full Text Available The purpose of this study was to evaluate the role of diffusion weighted-magnetic resonance imaging (DW-MRI in the examination and classification of brain tumors, namely, glioma and meningioma. Our hypothesis was that as signal intensity variations on diffusion weighted (DW images depend on histology and cellularity of the tumor, analysing the signal intensity characteristics on DW images may allow differentiating between the tumor types. Towards this end the signal intensity variations on DW images of the entire tumor volume data of 20 subjects with glioma and 12 subjects with meningioma were investigated and quantified using signal intensity gradient (SIG parameter. The relative increase in the SIG values (RSIG for the subjects with glioma and meningioma was in the range of 10.08–28.36 times and 5.60–9.86 times, respectively, compared to their corresponding SIG values on the contralateral hemisphere. The RSIG values were significantly different between the subjects with glioma and meningioma (P<0.01, with no overlap between RSIG values across the two tumors. The results indicate that the quantitative changes in the RSIG values could be applied in the differential diagnosis of glioma and meningioma, and their adoption in clinical diagnosis and treatment could be helpful and informative.

  6. Preliminary study on hypoxic-ischemic encephalopathy in neonates with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Wang Xiaoming; Chen Liying; Lin Nan; Guo Qiyong

    2005-01-01

    Objective: To evaluate hypoxic-ischemic encephalopathy (HIE) in neonates with diffusion-weighted MR imaging, and to explore the value and limitation of diffusion-weighted imaging (DWI) compared with conventional magnetic resonance imaging. Methods: Conventional magnetic resonance T 1 -weighted imaging (T 1 WI) and DWI (b=700 s/mm 2 ) were performed in 36 neonates with HIE (average age, 8.44 days; range, 3 hours to 22 days), and the cortex and subcortical white matter, deep white matter, basal ganglia and thalamus, cerebral ventricle, and extra-cerebral interspace etc were observed. Results: Signal abnormalities were shown on DWI with hypoxic-ischemic insults, which included diffuse brain damage (19.4%, 7/36): extensive high signals in the regional cortex, subcortical and deep white matter; localized brain damage: high signals along lateral ventricular wall and triangular part (27.8%, 10/36 ), and punctate high signals in the frontal deep white matter (5.6%, 2/36). On T 1 WI, the incidence of the corresponding changes were 16.7% (6/36), 36.1% (13/36), and 30.6%(11/36), respectively. Hemorrhagic lesions demonstrated high signals on T 1 WI and no signals on DWI. Conclusion: DWI was applicable for acute HIE, and T 1 WI was suitable for subacute and chronic HIE. (authors)

  7. Diffusion-Weighted MR Imaging of Unusual White Matter Lesion in a Patient with Menkes Disease

    International Nuclear Information System (INIS)

    Lee, Eun Shin; Ryoo, Jae Wook; Choi, Dae Seob; Cho, Jae Min; Kwon, Soo Hyun; Shin, Hee Suk

    2007-01-01

    We report here on the diffusion-weighted imaging of unusual white matter lesions in a case of Menkes disease. On the initial MR imaging, the white matter lesions were localized in the deep periventricular white matter in the absence of diffuse cortical atrophy. The lesion showed diffuse high signal on the diffusion weighted images and diffuse progression and persistent hyperintensity on the follow up imaging. Our case suggests that the white matter lesion may precede diffuse cortical atrophy in a patient with Menkes disease. Menkes disease is an X-linked disorder that's caused by impaired intracellular transport of copper. We describe here the DWI findings of unusual and progressive white matter lesions in a case of Menkes disease. Menkes disease is an X-linked recessive disorder, and it is due to an inborn error of copper metabolism. The cause of Menkes disease has been isolated to a genetic defect in copper-transporting adenosine triphosphatase, and this results in low levels of intracellular copper. It is characterized clinically by failure to thrive, retarded mental and motor development, clonic seizure and peculiarly coarse, sparse and colorless scalp hair. These clinical findings can be explained by a dysfunction of the copper-dependent enzymes

  8. Cerebral infarction presenting pure motor mono-paresis. Diagnosis by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Oda, Masaya; Udaka, Fukashi; Nishinaka, Kazuto; Kubori, Tamotsu; Kameyama, Masakuni

    2001-01-01

    We studied 10 patients with acute ischemic cerebrovascular disorders presenting paralysis confined to one limb, unaccompanied by sensory signs (pure motor monoparesis, PMM) on diffusion-weighted MR imaging (DWI). DWI revealed fresh ischemic lesions in all patients, except for 2 cases of transient ischemic attack. On DWI, acute infarction in multiple lesions was identified, and small superficial lesions were clearly described. Superficial lesions were seen in 4 patients, and deep lesions were also seen in 4 patients. DWI is useful for lesion analysis in cerebral infarction with PMM. (author)

  9. Cerebral infarction presenting pure motor mono-paresis. Diagnosis by diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Masaya; Udaka, Fukashi; Nishinaka, Kazuto; Kubori, Tamotsu; Kameyama, Masakuni [Sumitomo Hospital, Osaka (Japan)

    2001-02-01

    We studied 10 patients with acute ischemic cerebrovascular disorders presenting paralysis confined to one limb, unaccompanied by sensory signs (pure motor monoparesis, PMM) on diffusion-weighted MR imaging (DWI). DWI revealed fresh ischemic lesions in all patients, except for 2 cases of transient ischemic attack. On DWI, acute infarction in multiple lesions was identified, and small superficial lesions were clearly described. Superficial lesions were seen in 4 patients, and deep lesions were also seen in 4 patients. DWI is useful for lesion analysis in cerebral infarction with PMM. (author)

  10. Whole-body diffusion-weighted imaging for staging malignant lymphoma in children

    Energy Technology Data Exchange (ETDEWEB)

    Kwee, Thomas C.; Takahara, Taro; Vermoolen, Malou A.; Mali, Willem P.; Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Bierings, Marc B. [University Medical Center Utrecht, Department of Pediatric Hematology, Utrecht (Netherlands)

    2010-10-15

    CT is currently the mainstay in staging malignant lymphoma in children, but the risk of second neoplasms due to ionizing radiation associated with CT is not negligible. Whole-body MRI techniques and whole-body diffusion-weighted imaging (DWI) in particular, may be a good radiation-free alternative to CT. DWI is characterized by high sensitivity for the detection of lesions and allows quantitative assessment of diffusion that may aid in the evaluation of malignant lymphomas. This article will review whole-body MRI techniques for staging malignant lymphoma with emphasis on whole-body DWI. Furthermore, future considerations and challenges in whole-body DWI will be discussed. (orig.)

  11. Normal diffusion-weighted imaging in cerebral air embolism complicating angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sayama, T.; Inamura, T.; Fukui, M. [Dept. of Neurosurgery, Kyushu University Hospital, Fukuoka (Japan); Mitani, M.; Yagi, H. [Dept. of Neurosurgery, Yagi Hospital, Fukuoka (Japan)

    2000-03-01

    We report a case of cerebral air embolism resulting from accidental air infection during cerebral angiography. A 60-year-old man was accidentally injected with air via the left subclavian artery. Angiography demonstrated air within the basilar artery. The patient showed signs of posterior circulation ischaemia (confusion, blindness, gaze palsy and hemiparesis). However, MRI, including diffusion-weighted imaging, showed no abnormality 4 h later. The patient was treated with hyperbaric oxygen within 5 h of the embolism. All symptoms and signs resolved completely within a week. (orig.)

  12. Measuring Restriction Sizes Using Diffusion Weighted Magnetic Resonance Imaging: A Review

    Directory of Open Access Journals (Sweden)

    Melanie Martin

    2013-01-01

    Full Text Available This article reviews a new concept in magnetic resonance as applied to cellular and biological systems. Diffusion weighted magnetic resonance imaging can be used to infer information about restriction sizes of samples being measured. The measurements rely on the apparent diffusion coefficient changing with diffusion times as measurements move from restricted to free diffusion regimes. Pulsed gradient spin echo (PGSE measurements are limited in the ability to shorten diffusion times and thus are limited in restriction sizes which can be probed. Oscillating gradient spin echo (OGSE measurements could provide shorter diffusion times so smaller restriction sizes could be probed.

  13. Ovarian adenofibromas and cystadenofibromas - Magnetic resonance imaging findings including diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Mayumi [Dept. of Radiology, Univ. of Tokushima, Tokushima (Japan)], e-mail: mayumi@clin.med.tokushima-u.ac.jp; Matsuzaki, Kenji; Harada, Masafumi [Dept. of Radiology, Univ. of Tokushima, Tokushima (Japan)

    2013-03-15

    Background: Ovarian adenofibromas (AF) and cystadenofibromas (CAF) belong to the surface epithelial-stromal tumors, and may appear as solid, or solid and cystic masses mimicking ovarian cancers. Purpose: To evaluate the capability of magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) measurement for the diagnosis of ovarian AF/CAF. Material and Methods: Magnetic resonance manifestations of 13 cases of ovarian AF/CAF were retrospectively evaluated. DWI was obtained in all 13 lesions, and mean ADC values in 11 lesions were compared with those in solid portions of 27 ovarian cancers. Results: Neither case with AF/CAF revealed high signal intensity on DWI, whereas all ovarian cancers showed high signal intensity on DWI. The ADC values in the solid portions of AF/CAF were significantly higher than those of ovarian cancers (P < 0.001). A cut-off value of 1.20 X 10{sup -3} mm{sup 2}/s for AF/CAF had a sensitivity of 82%, specificity of 93%, positive predictive value of 82%, and negative predictive value of 93%. Conclusion: DWI with ADC measurement may be helpful in differentiating AF/CAF from ovarian cancers.

  14. Diagnosis and quantification of hepatic fibrosis in children with diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Razek, Ahmed Abdel Khalek Abdel; Abdalla, Ahmed; Omran, Eman; Fathy, Abeer; Zalata, Khaled

    2011-01-01

    Purpose: To evaluate the accuracy of diffusion weighted MR imaging in diagnosis and quantification of hepatic fibrosis in children with chronic hepatitis. Materials and methods: Sixty-three consecutive children (40 boys, 23 girls, median age 9.3 years), with chronic hepatitis and thirty age matched volunteers underwent diffusion weighted MR imaging of the liver using a single shot echoplanar imaging with b-value = 0, 250, and 500 s/mm 2 . Liver biopsy was obtained with calculation of METAVIR score. The ADC value of the liver was correlated with METAVIR score. Receiver operating characteristic curve was done for diagnosis and grading of hepatic fibrosis. Results: There was statistical difference in the mean ADC value between volunteers and patients with hepatic fibrosis (P = 0.001) and in patients with different grades of METAVIR scores (P = 0.002). There was correlation between the mean ADC value and METAVIR score (r = 0.807, P = 0.001). The cut off point to predict fibrosis (1.7 x 10 -3 mm 2 /s) revealed 83% accuracy, 85% sensitivity, 82% specificity, 83% PPV, and 85% NPV. The area under the curve was 0.91 for F1, 0.85 for F2, 0.86 for F3 and 0.90 for F4. Conclusion: The apparent diffusion coefficient value is a promising quantitative parameter used for diagnosis and quantification of hepatic fibrosis in children with chronic hepatitis.

  15. Diagnosis and quantification of hepatic fibrosis in children with diffusion weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Razek, Ahmed Abdel Khalek Abdel, E-mail: arazek@mans.eun.eg [Diagnostic Radiology Department, Mansoura Faculty of Medicine, 62 ElNokrasi Street Meet Hadr, Mansoura 3512 (Egypt); Abdalla, Ahmed [Pediatric Department, Mansoura Faculty of Medicine, Mansoura (Egypt); Omran, Eman [Diagnostic Radiology Department, Mansoura Faculty of Medicine, 62 ElNokrasi Street Meet Hadr, Mansoura 3512 (Egypt); Fathy, Abeer [Pediatric Department, Mansoura Faculty of Medicine, Mansoura (Egypt); Zalata, Khaled [Diagnostic Pathology Department, Mansoura Faculty of Medicine, Mansoura (Egypt)

    2011-04-15

    Purpose: To evaluate the accuracy of diffusion weighted MR imaging in diagnosis and quantification of hepatic fibrosis in children with chronic hepatitis. Materials and methods: Sixty-three consecutive children (40 boys, 23 girls, median age 9.3 years), with chronic hepatitis and thirty age matched volunteers underwent diffusion weighted MR imaging of the liver using a single shot echoplanar imaging with b-value = 0, 250, and 500 s/mm{sup 2}. Liver biopsy was obtained with calculation of METAVIR score. The ADC value of the liver was correlated with METAVIR score. Receiver operating characteristic curve was done for diagnosis and grading of hepatic fibrosis. Results: There was statistical difference in the mean ADC value between volunteers and patients with hepatic fibrosis (P = 0.001) and in patients with different grades of METAVIR scores (P = 0.002). There was correlation between the mean ADC value and METAVIR score (r = 0.807, P = 0.001). The cut off point to predict fibrosis (1.7 x 10{sup -3} mm{sup 2}/s) revealed 83% accuracy, 85% sensitivity, 82% specificity, 83% PPV, and 85% NPV. The area under the curve was 0.91 for F1, 0.85 for F2, 0.86 for F3 and 0.90 for F4. Conclusion: The apparent diffusion coefficient value is a promising quantitative parameter used for diagnosis and quantification of hepatic fibrosis in children with chronic hepatitis.

  16. Brain MRI diffusion-weighted imaging in patients with classical phenylketonuria

    International Nuclear Information System (INIS)

    Manara, Renzo; Citton, Valentina; Carollo, Carla; Burlina, Alessandro P.; Ermani, Mario; Vespignani, Francesco; Burlina, Alberto B.

    2009-01-01

    The aim of this study was to grade magnetic resonance white matter abnormalities (WMAs) of classical phenylketonuria (cPKU) patients treated from birth and to compare sensitivity and specificity of T2-weighted and diffusion-weighted images (DWI). Twenty early-treated cPKU patients still on a low-phenylalanine diet (12 males; mean age 21.2 years) and 26 normal subjects (ten males; mean age 25.1 years) were enrolled. Typical T2- and diffusion-weighted WMAs were semiquantitatively graded according to Thompson score (TS). Besides, a regional magnetic resonance imaging (MRI) score (mTS) was developed according to extension and intensity of WMAs. Phenylalanine and tyrosine plasma concentrations before performing MRI and the amino acid mean levels collected the year before MRI (Tyr year and Phe year ) were measured. No patient with Phe year concentration below 460 μmol/L showed WMAs. In cPKU patients, TS and mTS were significantly higher on DWI than on T2 images (3.50 vs 2.65 and 23.65 vs 15.85, respectively, p year levels. Among the different MR sequences, DWI seems to be the most sensitive and reliable in detecting and grading the typical WMAs of cPKU patients. (orig.)

  17. Diagnostic value of diffusion weighted MRI and ADC in differential ...

    African Journals Online (AJOL)

    –49. 13. Namimoto T, Yamashita Y, Mitsuzaki K, Nakayama. Y, Tang Y, Takahashi M. Measurement of the apparent diffusion coefficient in diffuse renal disease by diffu- sionweighted echo-planar MR imaging. J Magn Reson Im- aging 1999 ...

  18. Diffusion-Weighted Magnetic Resonance Imaging in Cervical Lymphadenopathy: Report of Three Cases of Patients with Bartonella henselae Infection Mimicking Malignant Disease

    Energy Technology Data Exchange (ETDEWEB)

    Muenzel, D.; Gaa, J.; Rummeny, E. J.; Holzapfel, K. (Dept. of Radiology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Munich (Germany)); Duetsch, S.; Fauser, C. (Dept. of Otorhinolaryngology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Munich (Germany)); Slotta-Huspenina, J. (Dept. of Pathology, Klinikum rechts der Isar, Technische Universitaet Muenchen, Munich (Germany))

    2009-10-15

    Diffusion-weighted MR imaging is a potential technique for differentiation between benign and malignant lymph nodes. However, lymphadenopathy caused by Bartonella henselae infection shows low ADC values in diffusion weighted MRI as typically seen in malignant disease.

  19. Diffusion-weighted imaging: basic concepts and application in cerebral stroke and head trauma

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.

    2003-01-01

    Diffusion-weighted imaging (DWI) of the brain represents a new imaging technique that extends imaging from depiction of neuroanatomy to the level of function and physiology. DWI measures a fundamentally different physiological parameter compared with conventional MRI. Image contrast is related to differences in the diffusion rate of water molecules rather than to changes in total tissue water. DWI can reveal pathology in cases where conventional MRI remains unremarkable. DWI has proven to be highly sensitive in the early detection of acute cerebral ischemia and seems promising in the evaluation of traumatic brain injury. DWI can differentiate between lesions with decreased and increased diffusion. In addition, full-tensor DWI can evaluate the microscopic architecture of the brain, in particular white matter tracts, by measuring the degree and spatial distribution of anisotropic diffusion within the brain. This article reviews the basic concepts of DWI and its application in cerebral ischemia and traumatic brain injury. (orig.)

  20. The application of in vivo diffusion weighted magnetic resonance imaging on intracranial disorders

    International Nuclear Information System (INIS)

    Ebisu, Toshihiko; Naruse, Shoji; Horikawa, Yoshiharu

    1991-01-01

    Diffusion weighted magnetic resonance (MR) images were obtained by using motion-probing gradient (MPG) pulses in one or three orthogonal directions in the following subjects: (1) phantom models; (2) Wistar rats with experimentally induced brain edema; (3) normal volunteers, and patients with brain tumor, brain edema or cerebral infarction. A one direction method was capable of defining diffusion anisotropy of myelinated axonal fibers in white matter. A three orthogonal gradients method was useful for demonstrating the difference in the diffusion coefficients in various diseases due to its larger total gradient strength. Faster diffusion was detected in white matter parallel to the direction of MPG; and slower diffusion was detected perpendicular to the direction of MPG because the myelin sheath restricted water diffusion. Brain tumor and vasogenic edema were shown as faster diffusion, while cytotoxic edema, cerebral ischemia, and infarction (at the subacute or early chronic stage) were shown as slower diffusion. Thus, diffusion weighted MR imaging seemed to be a useful approach to qualitative and dynamic analyses of intracranial diseases. (N.K.)

  1. Clinical application of diffusion-weighted magnetic resonance imaging to intracranial disorders

    International Nuclear Information System (INIS)

    Yanaka, Kiyoyuki; Shirai, Shizuo; Kimura, Hiroshi; Kamezaki, Takao; Matsumura, Akira; Nose, Tadao.

    1995-01-01

    Diffusion-weighted magnetic resonance imaging was performed to determine the changes in water diffusion and to investigate the detectability of diffusion anisotropy in patients with intracranial disorders. Diffusion maps of the apparent diffusion coefficient (ADC) were created of 19 patients with cerebral infarction, five with intracerebral hematoma, four with glioma, four with meningioma, four with hydrocephalus, and five with subdural hematoma. ADC was increased in chronic cerebral infarction and glioma, and decreased in acute cerebral infarction, meningioma, and the marginal area of glioma compared with the ADC of the normal gray matter. There was a significant difference in ADC between the marginal and internal areas of glioma. Increased ADC may be due to increased vasogenic edema in infarction and a lack of significant restriction of diffusion within glioma. Decreased ADC can be attributed to restricted diffusion caused by cytotoxic edema in infarction and the underlying histological pattern of densely packed tumor cells in glioma. Diffusion anisotropy of the internal capsule was less detectable in pathological than normal hemispheres. Diffusion anisotropy was less detectable in patients with hydrocephalus and subdural hematoma. Intracranial lesions were thought to have influenced the compression of the brain structures and cells, resulting in decreased diffusion. The measurement of ADC by diffusion-weighted magnetic resonance imaging has the potential for greater understanding of the biophysical changes in various intracranial disorders, including correct diagnosis of cerebral infarction, and histological diagnosis of brain tumor. (author)

  2. Diffusion-weighted magnetic resonance imaging of symptomatic nerve root of patients with lumbar disk herniation

    International Nuclear Information System (INIS)

    Eguchi, Yawara; Ohtori, Seiji; Yamashita, Masaomi; Yamauchi, Kazuyo; Suzuki, Munetaka; Orita, Sumihisa; Kamoda, Hiroto; Arai, Gen; Ishikawa, Tetsuhiro; Miyagi, Masayuki; Ochiai, Nobuyasu; Kishida, Shunji; Inoue, Gen; Takahashi, Kazuhisa; Masuda, Yoshitada; Ochi, Shigehiro; Kikawa, Takashi; Toyone, Tomoaki; Takaso, Masashi; Aoki, Yasuchika

    2011-01-01

    Diffusion-weighted imaging (DWI) can provide valuable structural information that may be useful for evaluating pathological changes of the lumbar nerve root. Diffusion-weighted magnetic resonance (MR) neurography has recently been introduced as an alternative way to visualize nerves, but to date, quantitative DWI and MR neurography have not been applied to evaluate the pathology of lumbar nerve roots. Our purpose was to visualize lumbar nerve roots and to analyze their morphology by MR neurography, and to measure the apparent diffusion coefficient (ADC) of lumbar nerve roots compressed by herniated disks using 1.5-T MR imaging. Ten consecutive patients (median age, 48.0 and range, 20-72 years) with monoradicular symptoms caused by a lumbar herniated disk and 14 healthy volunteers were studied. Regions of interests were placed on the lumbar roots at dorsal root ganglia (DRG) and distal spinal nerves on DWI to quantify mean ADC values. The spinal nerve roots were also visualized by MR neurography. In the patients, mean ADC values were significantly greater in the compressed DRG and distal spinal nerves than in intact nerves. MR neurography also showed abnormalities such as nerve swelling at and below the compression in the symptomatic nerve root. Increased ADC values were considered to be because of edema and Wallerian degeneration of compressed nerve roots. DWI is a potential tool for analysis of the pathophysiology of lumbar nerve roots compressed by herniated disks. (orig.)

  3. Clinical application of diffusion-weighted magnetic resonance imaging to intracranial disorders

    Energy Technology Data Exchange (ETDEWEB)

    Yanaka, Kiyoyuki; Shirai, Shizuo; Kimura, Hiroshi [Soujinkai Hospital, Ibaraki (Japan); Kamezaki, Takao; Matsumura, Akira; Nose, Tadao

    1995-09-01

    Diffusion-weighted magnetic resonance imaging was performed to determine the changes in water diffusion and to investigate the detectability of diffusion anisotropy in patients with intracranial disorders. Diffusion maps of the apparent diffusion coefficient (ADC) were created of 19 patients with cerebral infarction, five with intracerebral hematoma, four with glioma, four with meningioma, four with hydrocephalus, and five with subdural hematoma. ADC was increased in chronic cerebral infarction and glioma, and decreased in acute cerebral infarction, meningioma, and the marginal area of glioma compared with the ADC of the normal gray matter. There was a significant difference in ADC between the marginal and internal areas of glioma. Increased ADC may be due to increased vasogenic edema in infarction and a lack of significant restriction of diffusion within glioma. Decreased ADC can be attributed to restricted diffusion caused by cytotoxic edema in infarction and the underlying histological pattern of densely packed tumor cells in glioma. Diffusion anisotropy of the internal capsule was less detectable in pathological than normal hemispheres. Diffusion anisotropy was less detectable in patients with hydrocephalus and subdural hematoma. Intracranial lesions were thought to have influenced the compression of the brain structures and cells, resulting in decreased diffusion. The measurement of ADC by diffusion-weighted magnetic resonance imaging has the potential for greater understanding of the biophysical changes in various intracranial disorders, including correct diagnosis of cerebral infarction, and histological diagnosis of brain tumor. (author).

  4. Diffusion-weighted magnetic resonance imaging of femoral head osteonecrosis in two groups of patients: Legg-Perthes-Calve and Avascular necrosis.

    Science.gov (United States)

    Ozel, Betul Duran; Ozel, Deniz; Ozkan, Fuat; Halefoglu, Ahmet M

    2016-03-01

    The aim of this prospective study was to evaluate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) in patients with osteonecrosis. Patients were divided into two subgroups as avascular necrosis (AVN) of femoral head for adult group and Legg-Calvé-Perthes (LCP) patients for children. Seventeen patients with femoral head AVN (mean age 42.3 years) and 17 patients with LCP (mean age 8.2 years) were included in this study. Diagnosis confirmed with clinical and other imaging procedures among the patients complaining hip pain. DW images were obtained using the single-shot echo planar sequence and had b values of 0, 500, 1000 s/mm(2). The apparent diffusion coefficient (ADC) values were measured from ADC maps in epiphysis of patients with AVN, both from metaphysis and epiphysis in patients with LCP, respectively. Mann-Whitney U test was used to compare ADC values. The mean ADC value of femoral heads (1.285 ± 0.204 × 10(-3) mm(2)/s) was increased in patients with AVN when compared to normal bone tissue (0.209 ± 0.214 × 10(-3) mm(2)/s) (p < 0.01). The mean ADC values (×10(-3) mm(2)/s) of both metaphysis (0.852 ± 0.293) and epiphysis (0.843 ± 0.332) were also increased in patients with LCP and differences were statistically significant (p < 0.01). As a result, osteonecrosis shows increased ADC values. But it is a controversial concept that DWI offers a valuable data to conventional MRI or not. However, as there are report states, there is a correlation between the stage of the disease with ADC values in the LCP disease. DWI is a fast, without-contrast administration technique and provides quantitative values additional to conventional MR techniques; we believe DWI may play an additional assistance to the diagnosis and treatment for LCP patients. Multicentric larger group studies may provide additional data to this issue.

  5. Marchiafava-Bignami disease with hyperintensity on late diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Iwai, Takayasu; Matsuo, Koushun; Morii-Kitani, Fukiko; Azuma, Fumiko; Matsuo, Hisayasu; Takada, Masahiko; Nakagawa, Masanori; Mizuno, Toshiki; Yamada, Kei

    2014-01-01

    A 69-year-old man with a decades-long history of chronic alcohol consumption was admitted with gait disturbance (short steps and spasticity), deterioration of activity, and stuporous consciousness. Head magnetic resonance imaging (MRI) revealed hyperintensity on fluid-attenuated inversion recovery imaging in the corpus callosum and frontal white matter. The lesion later became more apparent on diffusion-weighted imaging. The clinical diagnosis was Marchiafava-Bignami disease (MBD). As temporary treatment, refraining from alcohol consumption and administration of vitamins were prescribed. The condition of the patient gradually improved. The purposes of this study were to demonstrate the clinical and radiological variety of MBD and to identify practical methods of treatment of this pathology

  6. Diffusion weighted MR imaging in non-infarct lesions of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Karaarslan, E. [Department of Radiology, American Hospital, Sisli, Istanbul (Turkey)], E-mail: ercankaraarslan@yahoo.com; Arslan, A. [Department of Radiology, Kocaeli University Medical School, Kocaeli (Turkey)], E-mail: arzuarslan@netscape.net

    2008-03-15

    Diffusion weighted imaging (DWI) is a relatively new method in which the images are formed by the contrast produced by the random microscopic motion of water molecules in different tissues. Although DWI has been tried for different organ systems, it has been found its primary use in the central nervous system. The most widely used clinical application is in the detection of hyperacute infarcts and the differentiation of acute or subacute infarction from chronic infarction. Recently DWI has been applied to various other cerebral diseases. In this pictorial paper the authors demonstrated different DWI patterns of non-infarct lesions of the brain which are hyperintense in the diffusion trace image, such as infectious, neoplastic and demyelinating diseases, encephalopathies - including hypoxic-ischemic, hypertensive, eclamptic, toxic, metabolic and mitochondrial encephalopathies - leukodystrophies, vasculitis and vasculopathies, hemorrhage and trauma.

  7. Brain MRI diffusion-weighted imaging in patients with classical phenylketonuria

    Energy Technology Data Exchange (ETDEWEB)

    Manara, Renzo; Citton, Valentina; Carollo, Carla [University Hospital of Padua, Neuroradiologic Unit, Padua (Italy); Burlina, Alessandro P.; Ermani, Mario [University Hospital of Padua, Neurological Clinic, Department of Neuroscience, Padua (Italy); Vespignani, Francesco; Burlina, Alberto B. [University Hospital of Padua, Metabolic Diseases Unit, Department of Paediatrics, Padua (Italy)

    2009-12-15

    The aim of this study was to grade magnetic resonance white matter abnormalities (WMAs) of classical phenylketonuria (cPKU) patients treated from birth and to compare sensitivity and specificity of T2-weighted and diffusion-weighted images (DWI). Twenty early-treated cPKU patients still on a low-phenylalanine diet (12 males; mean age 21.2 years) and 26 normal subjects (ten males; mean age 25.1 years) were enrolled. Typical T2- and diffusion-weighted WMAs were semiquantitatively graded according to Thompson score (TS). Besides, a regional magnetic resonance imaging (MRI) score (mTS) was developed according to extension and intensity of WMAs. Phenylalanine and tyrosine plasma concentrations before performing MRI and the amino acid mean levels collected the year before MRI (Tyr{sub year} and Phe{sub year}) were measured. No patient with Phe{sub year} concentration below 460 {mu}mol/L showed WMAs. In cPKU patients, TS and mTS were significantly higher on DWI than on T2 images (3.50 vs 2.65 and 23.65 vs 15.85, respectively, p<0.002, Wilcoxon test). All controls were scored 0 on DWI, while in T2 images, TS and mTS were 0.19 and 1.70. DWI evaluated by mTS disclosed a frontotemporal, occipital, and parietal WM progressive involvement. TS and mTS, both on T2 images and on DWI, showed no correlation with tyrosine while they proved to have a strong correlation with phenylalaninemia and an excellent one with Phe{sub year} levels. Among the different MR sequences, DWI seems to be the most sensitive and reliable in detecting and grading the typical WMAs of cPKU patients. (orig.)

  8. Apparent Diffusion Coefficient Value of Diffusion-Weighted Imaging for Hepatocellular Carcinoma: Correlation with the Histologic Differentiation and the Expression of Vascular Endothelial Growth Factor

    International Nuclear Information System (INIS)

    Heo, Suk Hee; Jeong, Yong Yeon; Kim, Jin Woong; Lim, Hyo Soon; Lee, Jae Hyuk; Koh, Yang Seok; Cho, Chol Kyoon; Kang, Heoung Keun; Shin, Sang Soo

    2010-01-01

    To evaluate whether the histopathological differentiation and the expression of vascular endothelial growth factor (VEGF) of hepatocellular carcinoma (HCC) do show correlation with the apparent diffusion coefficient (ADC) value on diffusion-weighted imaging (DWI). Twenty-seven HCCs from 27 patients who had undergone preoperative liver MRI (1.5T) and surgical resection were retrospectively reviewed. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1,000 sec/mm 2 ). On DWIs, the ADC value of the HCCs was measured by one radiologist, who was kept 'blinded' to the histological findings. Histopathologically, the differentiation was classified into well (n = 9), moderate (n = 9) and poor (n = 9). The expression of VEGF was semiquantitatively graded as grade 0 (n = 8), grade 1 (n = 9) and grade 2 (n = 10). We analyzed whether the histopathological differentiation and the expression of VEGF of the HCC showed correlation with the ADC value on DWI. The mean ADC value of the poorly-differentiated HCCs (0.9 ± 0.13x 10 -3 mm 2 /s) was lower than those of the well-differentiated HCCs (1.2 ± 0.22x 10 -3 mm 2 /s) (p = 0.031) and moderately-differentiated HCCs (1.1 ± 0.01x10 -3 mm 2 /s) (p = 0.013). There was a significant correlation between the differentiation and the ADC value of the HCCs (r = -0.51, p = 0.012). The mean ADC of the HCCs with a VEGF expression grade of 0, 1 and 2 was 1.1 ± 0.17, 1.1 ± 0.21 and 1.1 ± 0.18x10 -3 mm 2 /s, respectively. The VEGF expression did not show correlation with the ADC value of the HCCs (r = 0.07, p = 0.74). The histopathological differentiation of HCC shows inverse correlation with the ADC value. Therefore, DWI with ADC measurement may be a valuable tool for noninvasively predicting the differentiation of HCC

  9. Evaluating segmentation algorithms for diffusion-weighted MR images: a task-based approach

    Science.gov (United States)

    Jha, Abhinav K.; Kupinski, Matthew A.; Rodríguez, Jeffrey J.; Stephen, Renu M.; Stopeck, Alison T.

    2010-02-01

    Apparent Diffusion Coefficient (ADC) of lesions obtained from Diffusion Weighted Magnetic Resonance Imaging is an emerging biomarker for evaluating anti-cancer therapy response. To compute the lesion's ADC, accurate lesion segmentation must be performed. To quantitatively compare these lesion segmentation algorithms, standard methods are used currently. However, the end task from these images is accurate ADC estimation, and these standard methods don't evaluate the segmentation algorithms on this task-based measure. Moreover, standard methods rely on the highly unlikely scenario of there being perfectly manually segmented lesions. In this paper, we present two methods for quantitatively comparing segmentation algorithms on the above task-based measure; the first method compares them given good manual segmentations from a radiologist, the second compares them even in absence of good manual segmentations.

  10. The utility of diffusion-weighted MR imaging in differentiation of uterine adenomyosis and leiomyoma

    International Nuclear Information System (INIS)

    Yang Qiong; Zhang Lihua; Su Jing; Liu Jianyu

    2011-01-01

    Purpose: To investigate the value of diffusion-weighted MR imaging (DWI), especially apparent diffusion coefficient (ADC) in the differentiation of uterine adenomyosis and leiomyoma. Materials and methods: 17 patients with uterine leiomyoma and 22 patients with uterine adenomyosis underwent diffusion-weighted imaging (DWI) in addition to routine MR imaging. The ADC values, as well as ADC D-value (defined as the ADC value of high signal intensive foci minus the ADC value of lesion tissues the difference in value), were measured and compared to investigate whether they could help in the differentiation of uterine adenomyosis and leiomyoma. Histopathologic examination was conducted as the golden standard. Results: For high signal intensive foci within the lesions, uterine adenomyosis demonstrated significantly lower mean ADC value than uterine leiomyoma (1.582 vs. 2.122 x 10 -3 mm 2 /s, P = 0.001). For lesion tissues, uterine adenomyosis demonstrated significantly higher mean ADC value than uterine leiomyoma (1.214 vs. 0.967 x 10 -3 mm 2 /s, P = 0.001). However, there was overlap between uterine adenomyosis and leiomyoma in both measurements. Mean ADC D-value was significantly lower in uterine adenomyosis than in uterine leiomyoma (0.369 vs. 1.096 x 10 -3 mm 2 /s, P = 0.000). ADC D-value had no overlap between uterine adenomyosis and leiomyoma. Conclusion: DWI can be applied for the further differentiation of uterine adenomyosis and leiomyoma, in addition to routine MR imaging. ADC D-value may be a more useful tool than ADC value in the differentiation.

  11. Monitoring ankylosing spondylitis therapy by dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaspersic, Natasa [University Medical Centre, Department of Rheumatology, Ljubljana (Slovenia); Sersa, Igor [Jozef Stefan Institute, Ljubljana (Slovenia); Jevtic, Vladimir [Medical Faculty, Department of Radiology, Ljubljana (Slovenia); Tomsic, Matija; Praprotnik, Sonja [University Medical Centre, Department of Rheumatology, Ljubljana (Slovenia)

    2008-02-15

    The effects of different therapies on enthesitis/osteitis in active ankylosing spondylitis (AS) were evaluated by magnetic resonance imaging (MRI). The aim was to assess the role of quantitative MRI in the evaluation of AS treatment efficacy. Thirty patients with active spondylitis or bilateral sacroilitis were selected and followed up for 1 year. Ten of the patients were treated only with non-steroidal anti-inflammatory drugs, 10 patients additionally received at baseline an intravenous pulse of glucocorticoids and 10 patients were treated with regular infusions of infliximab. Disease activity was measured according to clinical instruments and laboratory tests. For each patient, one selected inflamed lesion was followed from baseline through control visits quantitatively by diffusion-weighted imaging (DWI) measuring the apparent diffusion coefficient (ADC) and by dynamic contrast-enhanced imaging (DCEI) with evaluation of the enhancement factor (f{sub enh}) and enhancement gradient (g{sub enh}). Clinical and quantitative MRI parameters diminished significantly with regression of the inflammatory activity. The improvement in AS was most pronounced in patients treated with infliximab; after 12 months the ADC diminished from an average of 1.31 to 0.88 x 10{sup -3} mm{sup 2}/s, f{sub enh} from 1.85 to 0.60, and g{sub enh} from 3.09 to 1.40 %/s. Diffusion-weighted imaging and DCEI were shown to be effective in quantifying changes in inflammation in skeletal lesions during the treatment of AS, and could therefore be convenient for assessing treatment efficacy. To the best of our knowledge this is the first time DWI was used to evaluate the activity of skeletal inflammation in rheumatic diseases such as AS. (orig.)

  12. Selected clinically established and scientific techniques of diffusion-weighted MRI. In the context of imaging in oncology; Ausgewaehlte klinisch etablierte und wissenschaftliche Techniken der diffusionsgewichteten MRT. Im Kontext der onkologischen Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Freitag, M.T.; Bickelhaupt, S.; Ziener, C.; Mosebach, J.; Schlemmer, H.P. [Deutsches Krebsforschungszentrum, Abteilung fuer Radiologie, Heidelberg (Germany); Meier-Hein, K. [Deutsches Krebsforschungszentrum, Abteilung fuer medizinische Informatik, Heidelberg (Germany); Radtke, J.P. [Deutsches Krebsforschungszentrum, Abteilung fuer Radiologie, Heidelberg (Germany); Universitaetsklinik Heidelberg, Abteilung fuer Urologie, Heidelberg (Germany); Kuder, T.A.; Laun, F.B. [Deutsches Krebsforschungszentrum, Abteilung fuer Medizinische Physik in der Radiologie, Heidelberg (Germany)

    2016-02-15

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique that was established in the clinical routine primarily for the detection of brain ischemia. In the past 15 years its clinical use has been extended to oncological radiology, as tumor and metastases can be depicted in DWI due to their hypercellular nature. The basis of DWI is the Stejskal-Tanner experiment. The diffusion properties of tissue can be visualized after acquisition of at least two diffusion-weighted series using echo planar imaging and a specific sequence of gradient pulses. The use of DWI in prostate MRI was reported to be one of the first established applications that found its way into internationally recognized clinical guidelines of the European Society of Urological Radiology (ESUR) and the prostate imaging reporting and data system (PI-RADS) scale. Due to recently reported high specificity and negative predictive values of 94 % and 92 %, respectively, its regular use for breast MRI is expected in the near future. Furthermore, DWI can also reliably be used for whole-body imaging in patients with multiple myeloma or for measuring the extent of bone metastases. New techniques in DWI, such as intravoxel incoherent motion imaging, diffusion kurtosis imaging and histogram-based analyses represent promising approaches to achieve a more quantitative evaluation for tumor detection and therapy response. (orig.) [German] Die diffusionsgewichtete Bildgebung (''diffusion-weighted imaging'', DWI), ein Verfahren aus der Magnetresonanztomographie (MRT), wurde in der klinischen Routine primaer fuer die Detektion von Schlaganfaellen etabliert. Der Einsatz dieser Methode hat in den letzten 15 Jahren auch fuer die onkologische Diagnostik stark zugenommen, da Tumoren und Metastasen aufgrund ihrer hochzellulaeren Zusammensetzung in der DWI sehr gut sichtbar gemacht werden koennen. Basis der diffusionsgewichteten Bildgebung ist das Experiment nach Stejskal-Tanner. Hier

  13. Detection of peritoneal dissemination in gynecological malignancy: evaluation by diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Shinya; Matsusue, Eiji; Kanasaki, Yoshiko; Nakanishi, Junko; Sugihara, Shuji; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago (Japan); Kanamori, Yasunobu; Kigawa, Junzo; Terakawa, Naoki [Tottori University, Division of Reproductive-Perinatal Medicine and Gynecological Oncology, Department of Surgery, Faculty of Medicine, Yonago (Japan)

    2008-01-15

    The aim of this study is to evaluate the usefulness of diffusion-weighted (DW) magnetic resonance (MR) imaging in detecting peritoneal dissemination in cases of gynecological malignancy. We retrospectively analyzed MR images obtained from 26 consecutive patients with gynecological malignancy. Peritoneal dissemination was histologically diagnosed in 15 of the 26 patients after surgery. We obtained DW images and half-Fourier single-shot turbo-spin-echo images in the abdomen and pelvis, and then generated fusion images. Coronal maximum-intensity-projection images were reconstructed from the axial source images. Reader interpretations were compared with the laparotomy findings in the surgical records. Receiver-operating characteristic (ROC) curves were used to represent the presence of peritoneal dissemination. In addition, the sensitivity and specificity were calculated. DW imaging depicted the tumors in 14 of 15 patients with peritoneal dissemination as abnormal signal intensity. ROC analysis yielded Az values of 0.974 and 0.932 for the two reviewers. The mean sensitivity and specificity were 90 and 95.5%. DW imaging plays an important role in the diagnosis and therapeutic management of patients with gynecological malignancy. (orig.)

  14. Role of Diffusion-Weighted Magnetic Resonance Imaging in Diffuse Axonal Injury

    Energy Technology Data Exchange (ETDEWEB)

    Ezaki, Y.; Tsutsumi, K.; Morikawa, M.; Nagata, I. [Nagasaki Univ., Graduate School of Medicine (Japan). Depts. of Neurosurgery and Radiology

    2006-09-15

    Purpose: To determine whether the signal changes on magnetic resonance imaging (MRI), including fluid attenuated inversion recovery (FLAIR), T2*-weighted gradient echo (GE) imaging, and diffusion-weighted imaging (DWI) in diffuse axonal injury (DAI) patients correlate with the clinical outcome. Material and Methods: We diagnosed patients with DAI based on the following criteria: 1) a loss of consciousness from the time of injury that persisted beyond 6 h; 2) no apparent hemorrhagic contusion on computed tomography (CT); 3) the presence of white matter injury on MRI. Twenty-one DAI patients were analyzed (19 M, 2 F, mean age 34 years) with MRI (FLAIR, T2*-weighted GE imaging, and DWI). Results: 325 abnormalities were detected by MRI within a week after injury. The T2*-weighted GE imaging was significantly more sensitive than FLAIR and DWI in diagnosing DAI. DWI detected only 32% of all lesions, but could depict additional shearing injuries not visible on either T2*-weighted GE imaging or FLAIR. The mean number of lesions in brainstem detected by DWI in the favorable group (good recovery/moderately disabled) was significantly smaller than in the unfavorable group (severely disabled/vegetative survival/death). This trend was not observed on the T2*-weighted GE imaging and FLAIR findings. Conclusion: DWI cannot detect all DAI-related lesions, but is a potentially useful imaging modality for both diagnosing and assessing patients with DAI.

  15. Rosai-Dorfman Disease with Epidural and Spinal Bone Marrow Involvement: Magnetic Resonance Imaging and Diffusion-Weighted Imaging Features

    International Nuclear Information System (INIS)

    Oner, A.Y.; Akpek, S.; Tali, T.

    2007-01-01

    Sinus histiocytosis with massive lymphadenopathy (SHML), or Rosai-Dorfman disease, is a rare histiocytic disorder that typically presents with chronic, self-limiting cervical lymphadenopathy. Although this disease mainly affects histiocytes, there are a few reports of bone marrow infiltration. Diffusion-weighted imaging (DWI) is a promising technology in differentiating between various bone marrow pathologies. We here present conventional magnetic resonance imaging and DWI features of a patient with SHML and bone marrow involvement

  16. Rosai-Dorfman Disease with Epidural and Spinal Bone Marrow Involvement: Magnetic Resonance Imaging and Diffusion-Weighted Imaging Features

    Energy Technology Data Exchange (ETDEWEB)

    Oner, A.Y.; Akpek, S.; Tali, T. [Dept. of Radiology, Gazi Univ. School of Medicine. Besevler-Ankara (Turkey)

    2007-04-15

    Sinus histiocytosis with massive lymphadenopathy (SHML), or Rosai-Dorfman disease, is a rare histiocytic disorder that typically presents with chronic, self-limiting cervical lymphadenopathy. Although this disease mainly affects histiocytes, there are a few reports of bone marrow infiltration. Diffusion-weighted imaging (DWI) is a promising technology in differentiating between various bone marrow pathologies. We here present conventional magnetic resonance imaging and DWI features of a patient with SHML and bone marrow involvement.

  17. Diffusion Weighted/Tensor Imaging, Functional MRI and Perfusion Weighted Imaging in Glioblastoma—Foundations and Future

    Directory of Open Access Journals (Sweden)

    Gayle R. Salama

    2018-01-01

    Full Text Available In this article, we review the basics of diffusion tensor imaging and functional MRI, their current utility in preoperative neurosurgical mapping, and their limitations. We also discuss potential future applications, including implementation of resting state functional MRI. We then discuss perfusion and diffusion-weighted imaging and their application in advanced neuro-oncologic practice. We explain how these modalities can be helpful in guiding surgical biopsies and differentiating recurrent tumor from treatment related changes.

  18. Differential diagnostic value of diffusion weighted imaging on brain abscess and necrotic or cystic brain tumors

    International Nuclear Information System (INIS)

    Zhang Xiaoya; Yin Jie; Wang Kunpeng; Zhang Jiandang; Liang Biling

    2009-01-01

    Objective: To investigate the value of diffusion weighted imaging (DWI)on brain abscess and necrotic or cystic brain tumors. Methods: 27 cases with brain abscesses and 33 cases with necrotic or cystic brain tumors (gliomas or metastases) were performed conventional MRI and DWI. Apparent diffusion coefficient (ADC) of region of interest (ROI) was measured and statistically tested. Sensitivity and specificity were calculated and compared with conventional MR and DWI. Results: Hyperintensity signal was seen on most brain abscesses. All necrotic or cystic brain tumors showed hypointensity signal on DWI. There was statistical significance on ADC of them. The sensitivity and specificity of conventional MRI was lower than that of DWI. Conclusion: DWI and ADC were useful in distinguishing brain abscessed from necrotic or cystic brain tumors, which was important in addition to conventional MRI. (authors)

  19. Diffusion-weighted imaging in chronic Behcet patients with and without neurological findings

    Energy Technology Data Exchange (ETDEWEB)

    Baysal, T.; Dogan, M.; Bulut, T.; Sarac, K. [Inonu University School of Medicine, Department of Radiology, Malatya (Turkey); Karlidag, R. [Inonu University School of Medicine, Department of Psychiatry, Malatya (Turkey); Ozisik, H.I. [Inonu University School of Medicine, Department of Neurology, Malatya (Turkey); Baysal, O. [Inonu University School of Medicine, Department of Physical Therapy and Rehabilitation, Malatya (Turkey)

    2005-06-01

    Our aim was to investigate whether neurological impairment in chronic Behcet's disease (BD) patients with normal appearing brain can be assessed by means of diffusion-weighted imaging (DWI). The averaged apparent diffusion coefficient (ADC) values were calculated in 22 different radiologically normal appearing brain regions in 32 patients with and without neurological findings and 20 control subjects. The ADC values in bilateral frontal, temporal and occipital normal appearing white matter were significantly higher in the patient groups compared with the control subjects (p<0.05). In these brain regions, DWI revealed differences in the ADC values between patients with neurological findings (including symptomatic and neuro-Behcet patients) and the asymptomatic patient group. The similarity of the ADC values of patients without symptoms to those of the control group allowed clear discrimination between patients with and without neurological findings. DWI may serve to assess subclinical neurological involvement in BD, even when structural changes are absent. (orig.)

  20. Diffusion-weighted imaging in chronic Behcet patients with and without neurological findings

    International Nuclear Information System (INIS)

    Baysal, T.; Dogan, M.; Bulut, T.; Sarac, K.; Karlidag, R.; Ozisik, H.I.; Baysal, O.

    2005-01-01

    Our aim was to investigate whether neurological impairment in chronic Behcet's disease (BD) patients with normal appearing brain can be assessed by means of diffusion-weighted imaging (DWI). The averaged apparent diffusion coefficient (ADC) values were calculated in 22 different radiologically normal appearing brain regions in 32 patients with and without neurological findings and 20 control subjects. The ADC values in bilateral frontal, temporal and occipital normal appearing white matter were significantly higher in the patient groups compared with the control subjects (p<0.05). In these brain regions, DWI revealed differences in the ADC values between patients with neurological findings (including symptomatic and neuro-Behcet patients) and the asymptomatic patient group. The similarity of the ADC values of patients without symptoms to those of the control group allowed clear discrimination between patients with and without neurological findings. DWI may serve to assess subclinical neurological involvement in BD, even when structural changes are absent. (orig.)

  1. Diffusion-weighted imaging and cognition in the leukoariosis and disability in the elderly study

    DEFF Research Database (Denmark)

    Schmidt, Reinhold; Ropele, Stefan; Ferro, José

    2010-01-01

    : Increasing WMH scores were associated with a higher frequency of hypertension, a greater WMH volume, more brain atrophy, worse overall cognitive performance, and changes in ADC. We found strong associations between the peak height of the ADC histogram of whole-brain tissue and NABT with memory performance......BACKGROUND AND PURPOSE: The mechanisms by which leukoariosis impacts on clinical and cognitive functions are not yet fully understood. We hypothesized that ultrastructural abnormalities of the normal-appearing brain tissue (NABT) assessed by diffusion-weighted imaging played a major and independent...... without previous disability. WMH severity was rated according to the Fazekas score. Multivariate regression analysis served to assess correlations of histogram metrics of the apparent diffusion coefficient (ADC) of whole-brain tissue, NABT, and of the mean ADC of WMH with cognitive functions. RESULTS...

  2. Single breath-hold diffusion-weighted MRI of the liver with parallel imaging: initial experience

    International Nuclear Information System (INIS)

    Oner, A.Y.; Celik, H.; Oktar, S.O.; Tali, T.

    2006-01-01

    Aim: To evaluate prospectively the improvement in the signal:noise ratio (SNR), with the use of parallel technique in single breath-hold diffusion-weighted imaging (DWI) of the liver and its affect on apparent diffusion coefficient (ADC) measurements. Materials and methods: This study was approved by our institutional review board. Written informed consent was obtained from all participants. Fifteen patients underwent single breath-hold DWI of the liver with and without parallel imaging technique. SNR and ADC values were measured over a lesion-free right hepatic lobe by two radiologists in both series. When a focal hepatic lesion was present the contrast:noise ratio (CNR) and ADC were also measured. Paired Student's t-tests were used for statistical analysis. Results: Mean SNR values of the liver were 20.82 ± 7.54 and 15.83 ± 5.95 for DWI with and without parallel imaging, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher (p -3 mm 2 /s and 1.56 ± 0.28 x 10 -3 mm 2 /s for DWI with and without parallel imaging, respectively. No significant difference was found between the two sequences for hepatic ADC measurement (p > 0.05). Overall lesion CNR was found to be higher in DWI with parallel imaging. Conclusion: Parallel imaging is useful in improving SNR of single breath-hold DWI of the liver without compromising ADC measurements

  3. Diffusion-weighted imaging in transient global amnesia exposes the CA1 region of the hippocampus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Yun; Kim, Jae Hyoung; Weon, Young-Cheol; Youn, Sung Won; Kim, Sung Hyun [Seoul National University Bundang Hospital, Department of Radiology, Seoul National University College of Medicine, Seongnam-si (Korea); Lee, Jung Seok; Kim, Sang Yun [Seoul National University Bundang Hospital, Department of Neurology, Seoul National University College of Medicine, Seongnam-si (Korea)

    2007-06-15

    Transient global amnesia (TGA) is characterized by a sudden onset of anterograde amnesia without alteration of consciousness or personal identity. Interestingly, recent studies have reported a high frequency of small high-signal abnormalities in the hippocampus with diffusion-weighted (DW) imaging, and ischemia has been proposed as an etiology of TGA. We hypothesized that TGA lesions occur preferentially in the CA1 region of the hippocampus, known to be susceptible to ischemia. Over a 30-month period 34 patients with TGA underwent MRI including DW imaging within 4 days of symptom onset. Patients with high-signal abnormalities in the hippocampus on the initial DW images underwent subsequent DW and T2-weighted imaging in the coronal plane to identify the precise lesion locations. Fourteen patients had small (1-3 mm) high-signal abnormalities in the hippocampus unilaterally on DW images. One of these patients had two lesions in one hippocampus and therefore in total 15 lesions were identified: four in the hippocampal head, and 11 in the body. Eleven lesions in ten patients with available coronal images were clearly demonstrated on both coronal DW and T2-weighted images and were localized to the lateral portion of the hippocampus, corresponding to the CA1 region. Lesions associated with TGA were localized exclusively to the lateral portion of the hippocampus corresponding to the CA1 region. This finding supports the ischemic etiology of TGA; however, the pathophysiological mechanism involved requires further study. (orig.)

  4. Diffusion-weighted imaging in transient global amnesia exposes the CA1 region of the hippocampus

    International Nuclear Information System (INIS)

    Lee, Ho Yun; Kim, Jae Hyoung; Weon, Young-Cheol; Youn, Sung Won; Kim, Sung Hyun; Lee, Jung Seok; Kim, Sang Yun

    2007-01-01

    Transient global amnesia (TGA) is characterized by a sudden onset of anterograde amnesia without alteration of consciousness or personal identity. Interestingly, recent studies have reported a high frequency of small high-signal abnormalities in the hippocampus with diffusion-weighted (DW) imaging, and ischemia has been proposed as an etiology of TGA. We hypothesized that TGA lesions occur preferentially in the CA1 region of the hippocampus, known to be susceptible to ischemia. Over a 30-month period 34 patients with TGA underwent MRI including DW imaging within 4 days of symptom onset. Patients with high-signal abnormalities in the hippocampus on the initial DW images underwent subsequent DW and T2-weighted imaging in the coronal plane to identify the precise lesion locations. Fourteen patients had small (1-3 mm) high-signal abnormalities in the hippocampus unilaterally on DW images. One of these patients had two lesions in one hippocampus and therefore in total 15 lesions were identified: four in the hippocampal head, and 11 in the body. Eleven lesions in ten patients with available coronal images were clearly demonstrated on both coronal DW and T2-weighted images and were localized to the lateral portion of the hippocampus, corresponding to the CA1 region. Lesions associated with TGA were localized exclusively to the lateral portion of the hippocampus corresponding to the CA1 region. This finding supports the ischemic etiology of TGA; however, the pathophysiological mechanism involved requires further study. (orig.)

  5. The Monitoring of Preoperative External Detorsion with Diffusion-Weighted Imaging in a Patient with Acute Testicular Torsion

    Directory of Open Access Journals (Sweden)

    Mehmet Beyazal

    2017-01-01

    Full Text Available Testicular torsion is one of the main causes of acute scrotum and may result in permanent damage of the testicular tissue. Color Doppler imaging has been frequently used in the diagnosis of testicular torsion and posttreatment follow-up period of the disease. There are some studies reporting the value and usefulness of diffusion-weighted imaging in the diagnosis of testicular torsion. However, to the best of our knowledge, there is no report regarding the monitoring of preoperative external detorsion in testicular torsion with diffusion-weighted imaging examination. In this article, diffusion-weighted imaging findings in the management of preoperative external detorsion in a case with testicular torsion were presented.

  6. MR diffusion weighted imaging detecting cerebral infarction: a meta-analysis

    International Nuclear Information System (INIS)

    Yang Junle; Xu Min; Wang Peng; Zhang Qiujuan; Guo Youmin; Liu Min

    2008-01-01

    Objective: To determine the diagnostic value of diffusion-weighted imaging(DWI) in hyperacute and acute cerebral infarction by using Meta-analysis. Methods: Based on validity criteria for diagnostic research published by the Cochrane Methods Group on Screening and Diagnostic, studies in English and Chinese from 1997 to 2007 were selected from Medline, Cochrane, Springer, Ovid, Elsevier, LWW and CNKI( China National Knowledge Infrastructure). The characteristics of the included articles were appraised and extracted. Statistical analysis was performed with the software Meta-test 0.6 and Comprehensive meta-analysis 2.0. Heterogeneity of the included articles was tested, which was used to select proper effect model to calculate pooled weighted values of sensitivity and specificity and the corresponding 95% CI. Summary receiver operating characteristic (SROC) curve was performed and the area under the curve (Az) was calculated. Publication bias was analyzed by Funnel Plot in Comprehensive Meta- analysis 2.0. A sensitivity analysis was performed. Results: Twelve articles meeting inclusion criteria were analyzed for the value of DWI in hyperacute cerebral infarction. The pooled sensitivity, specificity and diagnostic odds ratio was 92%, 87%, 180.37 respectively, Az=0.9717. Novice is a main factor for total diagnostic effect (Q=4.34, P>0.05). Non-asymmetric funnel plot suggested the publication bias. Fifteen articles meeting inclusion criteria were analyzed for the value of DWI in both hyperacute and acute cerebral infarction (≤ 24 h). The pooled sensitivity, specificity diagnostic odds ratio was 92%, 91%, 623.62 respectively, Az=0.9659. Fixed effects model used in Meta-analysis for database suggested homogeneity (Q=2.70,P>0.05). Nonasymmetric funnel plot suggested the publication bias. Conclusions As a noninvasive method, diffusion-weighted imaging is valuable in detecting hyperacute and acute cerebral infarction. More support from multi-center prospective researches is

  7. Diffusion-Weighted Imaging for Predicting New Compression Fractures Following Percutaneous Vertebroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, T. (Dept. of Radiology and Dept. of Neuropsychiatry, Kansai Medical Univ. Takii Hospital, Osaka (Japan)) (and others)

    2008-05-15

    Background: Percutaneous vertebroplasty (PVP) is a technique that structurally stabilizes a fractured vertebral body. However, some patients return to the hospital due to recurrent back pain following PVP, and such pain is sometimes caused by new compression fractures. Purpose: To investigate whether the apparent diffusion coefficient (ADC) of adjacent vertebral bodies as assessed by diffusion-weighted imaging before PVP could predict the onset of new compression fractures following PVP. Material and Methods: 25 patients with osteoporotic compression fractures who underwent PVP were enrolled in this study. ADC was measured for 49 vertebral bodies immediately above and below each vertebral body injected with bone cement before and after PVP. By measuring ADC for each adjacent vertebral body, ADC was compared between vertebral bodies with a new compression fracture within 1 month and those without new compression fractures. In addition, the mean ADC of adjacent vertebral bodies per patient was calculated. Results: Mean preoperative ADC for the six adjacent vertebral bodies with new compression fractures was 0.55x10-3 mm2/s (range 0.36-1.01x10-3 mm2/s), and for the 43 adjacent vertebral bodies without new compression fractures 0.20x10-3 mm2/s (range 0-0.98x10-3 mm2/s) (P<0.001). Mean preoperative ADC for the six patients with new compression fractures was 0.55x10-3 mm2/s (range 0.21-1.01x10-3 mm2/s), and that for the 19 patients without new compression fractures 0.17x10-3 mm2/s (range 0.01-0.43x10-3 mm2/s) (P<0.001). Conclusion: The ADC of adjacent vertebral bodies as assessed by diffusion-weighted imaging before PVP might be one of the predictors for new compression fractures following PVP

  8. MR imaging of primary sclerosing cholangitis - Additional value of diffusion-weighted imaging and ADC measurement

    Energy Technology Data Exchange (ETDEWEB)

    Djokicc Kovac, Jelena [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia)], e-mail: jelenadjokic2003@yahoo.co.uk; Maksimovic, Ruzica [Center for Radiology and Magnetic Resonance Imaging, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Jesic, Rada [Clinic for Gastroenterohepatology, Clinical Center Serbia, Belgrade (Serbia); Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Stanisavljevic, Dejana [Inst. for Statistics, Faculty of Medicine, Univ. of Belgrade, Belgrade (Serbia); Kovac, Bojan [Military Medical Academy, Belgrade (Serbia)

    2013-04-15

    Background: Primary sclerosing cholangitis (PSC) is a cholestatic liver disease with chronic inflammation and progressive destruction of biliary tree. Magnetic resonance (MR) examination with diffusion-weighted imaging (DWI) allows analysis of morphological liver parenchymal changes and non-invasive assessment of liver fibrosis. Moreover, MR cholangiopancreatography (MRCP), as a part of standard MR protocol, provides insight into bile duct irregularities. Purpose: To evaluate MR and MRCP findings in patients with primary sclerosing cholangitis and to determine the value of DWI in the assessment of liver fibrosis. Material and Methods: The following MR findings were reviewed in 38 patients: abnormalities in liver parenchyma signal intensity, changes in liver morphology, lymphadenopathy, signs of portal hypertension, and irregularities of intra- and extrahepatic bile ducts. Apparent diffusion coefficient (ADC) was calculated for six locations in the liver for b = 800 s/mm{sup 2}. Results: T2-weighted hyperintensity was seen as peripheral wedge-shaped areas in 42.1% and as periportal edema in 28.9% of patients. Increased enhancement of liver parenchyma on arterial-phase imaging was observed in six (15.8%) patients. Caudate lobe hypertrophy was present in 10 (26.3%), while spherical liver shape was noted in 7.9% of patients. Liver cirrhosis was seen in 34.2% of patients; the most common pattern was micronodular cirrhosis (61.5%). Other findings included lymphadenopathy (28.9%), signs of portal hypertension (36.7%), and bile duct irregularities (78.9%). The mean ADCs (x10{sup -3} mm{sup 2}/s) were significantly different at stage I vs. stages III and IV, and stage II vs. stage IV. No significant difference was found between stages II and III. For prediction of stage {>=}II and stage {>=}III, areas under receiver-operating characteristic curves were 0.891 and 0.887, respectively. Conclusion: MR with MRCP is a necessary diagnostic procedure for diagnosis of PSC and

  9. Diffusion-weighted magnetic resonance imaging indicates the severity of acute pancreatitis.

    Science.gov (United States)

    de Freitas Tertulino, Franklin; Schraibman, Vladimir; Ardengh, José Celso; do Espírito-Santo, Danilo Cerqueira; Ajzen, Sergio Aron; Torrez, Franz Robert Apodaca; Lobo, Edson Jose; Szejnfeld, Jacob; Goldman, Suzan Menasce

    2015-02-01

    To test the use of diffusion-weighted magnetic resonance imaging (DW-MRI) to differentiate between different degrees of severity of acute pancreatitis (AP). Thirty-six patients who underwent DW-MRI and magnetic resonance cholangiopancreatography were divided into patients with mild AP (mAP, n = 15), patients with necrotizing AP (nAP, n = 8), and patients with a normal pancreas (nP, n = 15; controls). The pancreas was divided into head, body, and tail, and each segment was classified according to image features: pattern 1, normal; pattern 2, mild inflammation; and pattern 3, necrosis. Apparent diffusion coefficients (ADCs) were measured in each segment and correlated with clinical diagnoses. A total of 108 segments was assessed (three segments per patient). Segments classified as pattern 1 in the nP and mAP groups showed similar ADC values (P = 0.29). ADC values calculated for the pancreatic segments grouped according to the different image patterns (1-3) were significantly different (P < 0.001). Comparisons revealed significant differences in signal intensity between all three patterns (P < 0.05). DW-MRI was a compatible and safe image option to differentiate tissue image patterns in patients with mAP, nAP, and nP, mainly in those with contraindications to contrast-enhanced MRI (which is classically required for determining the presence of necrosis) or computed tomography. ADC measures allowed precise differentiation between patterns 1, 2, and 3.

  10. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, M.; Sakamoto, S.; Ishii, K. [Division of Neuroimaging Research, Hyogo Institute for Aging Brain and Cognitive Disorders (Japan); Imamura, T.; Kazui, H.; Mori, E. [Division of Clinical Neurosciences, Hyogo Institute for Aging Brain and Cognitive Disorders, Hyogo (Japan)

    2002-03-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  11. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsui, M.; Sakamoto, S.; Ishii, K.; Imamura, T.; Kazui, H.; Mori, E.

    2002-01-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  12. Diffusion-weighted imaging of brain metastases: their potential to be misinterpreted as focal ischaemic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, B. [Department of Radiology, University Hospital, Lund (Sweden); Holtaas, S. [Department of Diagnostic Imaging, King Fahd Hospital, Riyadh (Saudi Arabia)

    2002-07-01

    Small focal ischaemic brain lesions are said to be easy to identify in the acute stage and to differentiate from older lesions using diffusion-weighted imaging (DWI). Brain metastases are common and the aim of this study was to evaluate the risk of misinterpretation as ischaemic lesions in a standard MRI protocol for clinical stroke. Of 26 patients investigated with MRI for possible metastases, 12 did have metastatic brain lesions, including most of the common tumours. On a 1.5 tesla imager, we obtained DWI, plus T2- and T1-weighted images, the latter before and after triple-dose contrast medium. Well-circumscribed brain lesions with a decreased apparent diffusion coefficient and a slightly or moderately increased signal on T2-weighted images were found in patients with metastases from a small-cell bronchial carcinoma and a pulmonary adenocarcinoma. The same features were also found in metastases from a breast carcinoma but the lesions were surrounded by oedema. With a standard DWI protocol, the features of common brain metastases may overlap with those of small acute and subacute ischaemic lesions. (orig.)

  13. Non-local diffusion-weighted image super-resolution using collaborative joint information.

    Science.gov (United States)

    Yang, Zhipeng; He, Peiyu; Zhou, Jiliu; Wu, Xi

    2018-01-01

    Due to the clinical durable scanning time and other physical constraints, the spatial resolution of diffusion-weighted magnetic resonance imaging (DWI) is highly limited. Using a post-processing method to improve the resolution of DWI holds the potential to improve the investigation of smaller white-matter structures and to reduce partial volume effects. In the present study, a novel non-local mean super-resolution method was proposed to increase the spatial resolution of DWI datasets. Based on a non-local strategy, joint information from the adjacent scanning directions was taken advantage of through the implementation of a novel weighting scheme. Besides this, an efficient rotationally invariant similarity measure was introduced for further improvement of high-resolution image reconstruction and computational efficiency. Quantitative and qualitative comparisons in synthetic and real DWI datasets demonstrated that the proposed method significantly enhanced the resolution of DWI, and is thus beneficial in improving the estimation accuracy for diffusion tensor imaging as well as high-angular resolution diffusion imaging.

  14. Clinical value of diffusion-weighted MR imaging in acute contusion of spinal cord

    International Nuclear Information System (INIS)

    Zhang Jinsong; Huan Yi; Sun Lijun; Zhao Haitao; Ge Yali; Chang Yingjuan; Yang Chunmin

    2005-01-01

    Objective: To study the clinical value of diffusion-weighted MR imaging (DWI) in acute contusion of spinal cord. Methods: Eighteen cases with acute contusion of spinal cord were examined with routine MRI and DWI, including single-shot DWI (ssh-DWI) in 2 cases and multi-shot DWI (msh-DWI) in 16 cases, on a 1.5-tesla MR system within 72 h post-trauma. Results: Two cases examined by ssh-DWI showed local lesions with significant high signals, but ssh-DWI images could not be used to measure apparent diffusion coefficient (ADC) value due to its weak resolution. Other 16 cases examined by msh-DWI showed better images and were classified into three categories depending on different degrees of tissue injury and characteristics of DWI: (1) Edema-type: ten cases presented DWI high signals with different degree in local lesions. There were significant difference of ADC values between lesions and normal parts (t=7.515, P 2 WI heterogeneous high signals and T 1 WI low signals due to prominent hemorrhage. Conclusion: DWI of the spinal cord provided satisfactory images and was a useful method for visualizing the injury cord in the super-early stage, helping determine integrity and compression degree of spinal cord and detecting hemorrhage. (authors)

  15. The significance of diffusion weighted imaging for the diagnosis of pyogenic ventriculitis

    Energy Technology Data Exchange (ETDEWEB)

    Ihn, Yon Kwon; Hwang, Seong Su [College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Kim, Tae You [Willis Hospital, Seoul (Korea, Republic of)

    2007-08-15

    To evaluate the significance of diffusion weighted imaging (DWI) for the diagnosis of pyogenic ventriculitis. In this retrospective study, 9 patients with pyogenic ventricultis underwent a set of imaging sequences that included DWI, T1-and T2-weighted imaging. FLAIR and enhanced T1 weighted imaging. DWI consisted of an axial single shot spine echo EPI pulse sequence with b values of 0 and 1000 sec/mm{sup 2}. We evaluated the presence and signal intensity of ventricular debris, hydrocephalus, periventricular signal abnormality, and ependymal enhancement. The apparent diffusion coffiecient values of ventricular debris and cortical gray matter were calculated from the ADC map. In all patients, ventricular debris was hyperintense on the DWIs. A periventricular hyperintense signal was present in all cases on FLAIR and T2WI. Ependymal enhancement was detected in eight (89%) of 9 cases. A hydrocephalus was observed in 6 (67%) of 9 cases. The mean ADC value of ventricular debris was 0.735 {+-} 0.117 (10{sup -3} mm{sup 2}/sec). These ADC values were significantly lower than those for cortical gray matter (1.052 {+-} 0.149 (10{sup -3} mm{sup 2}/sec)). Ventricular debris was most conspicuous findings of ventriculitis on DWI. Areas of intraventricular hyperintensity on DWI corresponded to the decreased ADC values.

  16. Multiband diffusion-weighted MRI of the eye and orbit free of geometric distortions using a RARE-EPI hybrid.

    Science.gov (United States)

    Paul, Katharina; Huelnhagen, Till; Oberacker, Eva; Wenz, Daniel; Kuehne, André; Waiczies, Helmar; Schmitter, Sebastian; Stachs, Oliver; Niendorf, Thoralf

    2018-03-01

    Diffusion-weighted imaging (DWI) provides information on tissue microstructure. Single-shot echo planar imaging (EPI) is the most common technique for DWI applications in the brain, but is prone to geometric distortions and signal voids. Rapid acquisition with relaxation enhancement [RARE, also known as fast spin echo (FSE)] imaging presents a valuable alternative to DWI with high anatomical accuracy. This work proposes a multi-shot diffusion-weighted RARE-EPI hybrid pulse sequence, combining the anatomical integrity of RARE with the imaging speed and radiofrequency (RF) power deposition advantage of EPI. The anatomical integrity of RARE-EPI was demonstrated and quantified by center of gravity analysis for both morphological images and diffusion-weighted acquisitions in phantom and in vivo experiments at 3.0 T and 7.0 T. The results indicate that half of the RARE echoes in the echo train can be replaced by EPI echoes whilst maintaining anatomical accuracy. The reduced RF power deposition of RARE-EPI enabled multiband RF pulses facilitating simultaneous multi-slice imaging. This study shows that diffusion-weighted RARE-EPI has the capability to acquire high fidelity, distortion-free images of the eye and the orbit. It is shown that RARE-EPI maintains the immunity to B 0 inhomogeneities reported for RARE imaging. This benefit can be exploited for the assessment of ocular masses and pathological changes of the eye and the orbit. Copyright © 2018 John Wiley & Sons, Ltd.

  17. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  18. Chronic kidney disease: Pathological and functional evaluation with intravoxel incoherent motion diffusion-weighted imaging.

    Science.gov (United States)

    Mao, Wei; Zhou, Jianjun; Zeng, Mengsu; Ding, Yuqin; Qu, Lijie; Chen, Caizhong; Ding, Xiaoqiang; Wang, Yaqiong; Fu, Caixia

    2018-05-01

    Because chronic kidney disease (CKD) is a worldwide problem, accurate pathological and functional evaluation is required for planning treatment and follow-up. Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) can assess both capillary perfusion and tissue diffusion and may be helpful in evaluating renal function and pathology. To evaluate functional and pathological alterations in CKD by applying IVIM-DWI. Prospective study. In all, 72 CKD patients who required renal biopsy and 20 healthy volunteers. 1.5T. All subjects underwent IVIM-DWI of the kidneys, and image analysis was performed by two radiologists. The mean values of true diffusion coefficient (D), pseudo diffusion coefficient (D*), and perfusion fraction (f) were acquired from renal parenchyma. Correlation between IVIM-DWI parameters and estimated glomerular filtration rate (eGFR), as well as pathological damage, were assessed. One-way analysis of variance (ANOVA), paired sample t-test and Spearman correlation analysis. The paired sample t-test revealed that IVIM-DWI parameters were significantly lower in medulla than cortex for both patients and controls (P Imaging 2018;47:1251-1259. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Heroin-induced leukoencephalopathy: characterization using MRI, diffusion-weighted imaging, and MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Offiah, C. [Department of Neuroradiology, St Bartholomew' s and the London Hospitals NHS Trust, London (United Kingdom); Hall, E. [Department of Neuroradiology, St Bartholomew' s and the London Hospitals NHS Trust, London (United Kingdom)], E-mail: curtis.offiah@bartsandthelondon.nhs.uk

    2008-02-15

    Aim: To describe the magnetic resonance imaging (MRI) characteristics of heroin-induced leukoencephalopathy or 'chasing the dragon syndrome' and, in particular, the diffusion-weighted imaging (DWI) and MR spectroscopy (MRS) features. Material and methods: Six patients with a clinical or histopathological diagnosis of heroin-induced leukoencephalopathy were identified and MRI examinations, including DWI and single-voxel MRS, reviewed. Results: Cerebellar white matter was involved in all six cases demonstrating similar symmetrical distribution with sparing of the dentate nuclei. Brain stem signal change was evident in five of the six patients imaged. Supratentorial brain parenchymal involvement, as well as brain stem involvement, correlated anatomically with corticospinal tract distribution. None of the areas of signal abnormality were restricted on DWI. Of those patients subjected to MRS, the areas of parenchymal damage demonstrated reduced N-acetylaspartate, reduced choline, and elevated lactate. Conclusion: Heroin-induced leukoencephalopathy results in characteristic and highly specific signal abnormalities on MRI, which can greatly aid diagnosis. DWI and MRS findings can be explained by known reported neuropathological descriptions in this condition and can be used to support a proposed mechanism for the benefit of current recommended drug treatment regimes.

  20. Clinical application of diffusion-weighted imaging in the femoral head necrosis patients

    International Nuclear Information System (INIS)

    Zhang Hongsheng; Xu Zushan; Yu Pingping

    2010-01-01

    Objective: To summarize and analyze the imaging features of diffusion-weighted imaging (DWI) in femoral head necrosis (FHN) patients and provide the basis for the diagnosis of FHN. Methods: The magnetic resonance signal distribution and apparent diffusion coefficient (ADC) in 22 normal person and 42 FHN patients were analyzed and compared. Results: The homogeneous high signal was showed in T1WI and T2WI imaging for normal person and low signal in DWI. The slightly low signal in T1WI, the high signal and slightly inhomogeneous signal in T2WI and the heterogeneous high signal in DWI were showed for FHN patients. The ADC normal value of normal person, the around area and central area of FHN patients were (0.000-0.036) x 10 -3 mm 2 /s, (0.111-0.311) x 10 -3 mm 2 /s and (0.845-1.397) x 10 -3 mm 2 /s respectively, there was statistically significant difference among three areas (F=1384.28, P<0.05). Conclusion: There is specificity in DWI signal distribution and ADC normal value in FHN patients compared with normal person. DWI can be used for the diagnosis of FHN patients and the ADC value can be used for quantify analysis of bone marrow lesions. (authors)

  1. Comparison of qualitative and quantitative evaluation of diffusion-weighted MRI and chemical-shift imaging in the differentiation of benign and malignant vertebral body fractures.

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Dürr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2012-11-01

    The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in- and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0

  2. Human cerebral cortices: signal variation on diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Asao, Chiaki [Kumamoto Regional Medical Center, Department of Radiology, Kumamoto (Japan); National Hospital Organization Kumamoto Medical Center, Department of Radiology, Kumamoto (Japan); Hirai, Toshinori; Yamashita, Yasuyuki [Kumamoto University Graduate School of Medical Sciences, Department of Diagnostic Radiology, Kumamoto (Japan); Yoshimatsu, Shunji [National Hospital Organization Kumamoto Medical Center, Department of Radiology, Kumamoto (Japan); Matsukawa, Tetsuya; Imuta, Masanori [Kumamoto Regional Medical Center, Department of Radiology, Kumamoto (Japan); Sagara, Katsuro [Kumamoto Regional Medical Center, Department of Internal Medicine, Kumamoto (Japan)

    2008-03-15

    We have often encountered high signal intensity (SI) of the cingulate gyrus and insula during diffusion-weighted magnetic resonance imaging (DW-MRI) on neurologically healthy adults. To date, cortical signal heterogeneity on DW images has not been investigated systematically. The purpose of our study was to determine whether there is regional signal variation in the brain cortices of neurologically healthy adults on DW-MR images. The SI of the cerebral cortices on DW-MR images at 1.5 T was evaluated in 50 neurologically healthy subjects (34 men, 16 women; age range 33-84 years; mean age 57.6 years). The cortical SI in the cingulate gyrus, insula, and temporal, occipital, and parietal lobes was graded relative to the SI of the frontal lobe. Contrast-to-noise ratios (CNRs) on DW-MR images were compared for each cortical area. Diffusion changes were analyzed by visually assessment of the differences in appearance among the cortices on apparent diffusion coefficient (ADC) maps. Increased SI was frequently seen in the cingulate gyrus and insula regardless of patient age. There were no significant gender- or laterality-related differences. The CNR was significantly higher in the cingulate gyrus and insula than in the other cortices (p <.01), and significant differences existed among the cortical regions (p <.001). There were no apparent ADC differences among the cortices on ADC maps. Regional signal variation of the brain cortices was observed on DW-MR images of healthy subjects, and the cingulate gyrus and insula frequently manifested high SI. These findings may help in the recognition of cortical signal abnormalities as visualized on DW-MR images. (orig.)

  3. Human cerebral cortices: signal variation on diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Asao, Chiaki; Hirai, Toshinori; Yamashita, Yasuyuki; Yoshimatsu, Shunji; Matsukawa, Tetsuya; Imuta, Masanori; Sagara, Katsuro

    2008-01-01

    We have often encountered high signal intensity (SI) of the cingulate gyrus and insula during diffusion-weighted magnetic resonance imaging (DW-MRI) on neurologically healthy adults. To date, cortical signal heterogeneity on DW images has not been investigated systematically. The purpose of our study was to determine whether there is regional signal variation in the brain cortices of neurologically healthy adults on DW-MR images. The SI of the cerebral cortices on DW-MR images at 1.5 T was evaluated in 50 neurologically healthy subjects (34 men, 16 women; age range 33-84 years; mean age 57.6 years). The cortical SI in the cingulate gyrus, insula, and temporal, occipital, and parietal lobes was graded relative to the SI of the frontal lobe. Contrast-to-noise ratios (CNRs) on DW-MR images were compared for each cortical area. Diffusion changes were analyzed by visually assessment of the differences in appearance among the cortices on apparent diffusion coefficient (ADC) maps. Increased SI was frequently seen in the cingulate gyrus and insula regardless of patient age. There were no significant gender- or laterality-related differences. The CNR was significantly higher in the cingulate gyrus and insula than in the other cortices (p <.01), and significant differences existed among the cortical regions (p <.001). There were no apparent ADC differences among the cortices on ADC maps. Regional signal variation of the brain cortices was observed on DW-MR images of healthy subjects, and the cingulate gyrus and insula frequently manifested high SI. These findings may help in the recognition of cortical signal abnormalities as visualized on DW-MR images. (orig.)

  4. Value of diffusion-weighted MR imaging in the diagnosis of Creutzfeldt-Jakob disease

    International Nuclear Information System (INIS)

    Xu Quangang; Wu Weiping; Huang Dehui; Zhang Jiatang; Lang Senyang; Pu Chuanqiang

    2005-01-01

    Objective: To assess the diagnosis value of diffusion- weighted imaging (DWI) in Creutzfeldt-Jakob disease (CJD). Methods: 8 cases of sporadic CJD who underwent MRI were reported. 4 cases were definite, 3 cases were probable and 1 case was possible. The sensitivity of DWI and conventional MRI were compared. Results: T 1 WI and T 2 WI revealed no abnormal signals except nonspecific diffuse brain atrophy in 4 cases, whereas DWI detected hyperintense abnormalities in all cases. 2 cases showed linear lesions only in the cerebral cortex, and 6 cases showed lesions in both the cerebral cortex and the striatum. The lesions were symmetric in 5 cases, but were asymmetric in the other 3 cases. Although fluid- attenuated inversion recovery (FLAIR) imaging also showed cortical hyperintensity in 1 case, the high signal changes were more evident and extensive on DWI. Conclusions: The hyperintense changes in the cerebral cortices and/or striata on DWI are considered characteristic of CJD. DWI is more sensitive than conventional MRI in depicting lesions of CJD and may be an essential tool for the early diagnosis of this disease. (authors)

  5. Diffusion-weighted imaging in head and neck squamous cell carcinomas: a systematic review.

    Science.gov (United States)

    Driessen, Juliette P; van Kempen, Paulina M W; van der Heijden, Geert J; Philippens, Marielle E P; Pameijer, Frank A; Stegeman, Inge; Terhaard, Chris H J; Janssen, Luuk M; Grolman, Wilko

    2015-03-01

    The purpose of this study was for us to review diagnostic accuracy of diffusion-weighted imaging (DWI) in primary head and neck squamous cell carcinomas (HNSCCs), detection of metastatic lymph nodes, and recurrences. A systematic review for studies concerning DWI was performed. Ten studies fulfilled inclusion criteria. All studies showed significant higher "apparent diffusion coefficient" (ADC) in benign compared to malignant lesions. ADC thresholds for optimal discrimination varied. In detection of primary HNSCC, the accuracy of DWI ranged from 66% to 86%. In metastatic lymph nodes, the accuracy of DWI was 85% to 91% and the negative predictive value (NPV) was higher than 91%. For recurrences, the accuracy of DWI was 78% to 100% and the NPV ranged from 77% to 100%. DWI showed consistent high accuracy and high NPV. However, available literature is sparse and varying ADC thresholds were reported. Compared to current imaging techniques, DWI showed the most potential in lymph node staging and detection of recurrences. © 2014 Wiley Periodicals, Inc.

  6. Head and neck paragangliomas: diffusion weighted and dynamic contrast enhanced magnetic resonance imaging characteristics

    International Nuclear Information System (INIS)

    Yuan, Ying; Shi, Huimin; Tao, Xiaofeng

    2016-01-01

    To determine the feature values of head and neck paragangliomas on diffusion-weighted imaging (DWI) and dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI). Patients with primary head and neck paraganglioma who underwent both DWI and DCE-MRI before treatment between January 2010 and June 2013 were identified. Two radiologists assessed apparent diffusion coefficient (ADC) values on DWI and kinetic characteristics on DCE-MRI. The time intensity curves (TICs) and dynamic parameters, including peak height (PH), maximum enhancement ratio (ER max ), time to peak enhancement (T peak ) and maximum rise slope (Slope max ), were generated and evaluated. Ten patients with head and neck paraganglioma were retrospectively analyzed. On conventional MRI, the tumors demonstrated as well-circumscribed, strongly enhanced lesions. Mean ADC value of the lesions was 1.12 ± 0.15 × 10 −3 mm 2 /s. The TICs demonstrated washout pattern (type-III) in all lesions. The mean PH, ER max , T peak and Slope max value was 121.24 ± 63.99, 193.79 ± 67.18, 8.16 ± 3.29 and 25.42 ± 7.91, respectively. Head and neck paragangliomas demonstrate distinctive DWI and DCE-MRI results than for other benign tumors which should be taken into account in further evaluation of MRI on head and neck lesions

  7. Carcinosarcoma of the uterus: MRI findings including diffusion-weighted imaging and MR spectroscopy.

    Science.gov (United States)

    Takeuchi, Mayumi; Matsuzaki, Kenji; Harada, Masafumi

    2016-10-01

    Recently carcinosarcoma has become regarded as a subset of endometrial carcinoma. Because the clinical course of carcinosarcoma is aggressive with poor prognosis, it should be differentiated from endometrial carcinomas for the appropriate surgical management and adjuvant therapy. To clarify the magnetic resonance imaging (MRI) characteristics of uterine carcinosarcoma including diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) measurement and MR spectroscopy (MRS) with quantitative metabolite evaluation. MRI findings of 12 pathologically diagnosed uterine carcinosarcomas obtained on 3T MRI were retrospectively evaluated. The mean and minimum ADCs, and the lipid and choline concentration levels were compared with those of pathologically diagnosed 38 endometrial carcinomas. The mean and minimum ADCs in carcinosarcomas and endometrial carcinomas were not significantly different. The mean ADC of carcinosarcomas was significantly higher than that of higher grade (G2 and G3) endometrial carcinomas. The choline concentration in carcinosarcomas was significantly lower than that in endometrial carcinomas. High lipid peak was observed in 91% of carcinosarcomas and in 24% of endometrial carcinomas. Large, exophytic heterogeneous endometrial mass containing strongly enhanced areas, which may exhibit "tumor delivery", is a suggestive of carcinosarcoma. Relatively high mean ADC and low choline concentration considering its highly malignant nature due to intra-tumoral heterogeneity with necrosis and epithelial cystic components, and the presence of necrosis-associated high lipid peak may be compatible with carcinosarcoma. © The Foundation Acta Radiologica 2016.

  8. Assessment of patency capsule retention using MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne [Sheba Medical Center, Department of Diagnostic Imaging, Ramat Gan (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami [Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Sheba Medical Center, Department of Gastroenterology, Ramat Gan (Israel)

    2017-12-15

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm{sup 2}/s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  9. Usefulness of MRI diffusion weighted images in cases of brainstem infarction

    Energy Technology Data Exchange (ETDEWEB)

    Hirose, Yoshikiyo; Mokuno, Kenji; Ito, Sayaka [Toyohashi Municipal Hospital, Aichi (Japan)

    1999-06-01

    We examined the chronological changes in usefulness of MRI diffusion weighted images (DWIs) in 30 patients with brain-stem infarction. All patients were admitted during acute phase and treatment was begun. Of the 30 patients, nine had lesions in the medulla oblongata, 18 in the pons, and three in the midbrain. Serial DWIs were done on 15 patients, and total 47 MRIs were evaluated. The first MRIs, taken within seven days after onset, showed high signal intensities on the DWIs of all 30 patients. The high signal intensities were more apparent on DWIs than on T{sub 2} weighted images (T{sub 2}WIs) in 21 patients, especially in those with small lesion. Moreover, the lesions of five patients with medullary infarction were seen only on DWIs. However, in nine patients with large pontine infarctions the lesions were recognizable on both DWIs and T{sub 2}WIs. As the days went on, the superiority of DWIs over T{sub 2}WIs in the early detection of the infarct lesions decreased, as the lesions gradually became apparent on T{sub 2}WIs as well. These results indicate that DWIs are useful in the early diagnosis of brainstem infarction, especially when the lesion is small. (author)

  10. Assessment of patency capsule retention using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne; Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami

    2017-01-01

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm 2 /s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  11. MR diffusion weighted imaging experimental study on early stages of articular cartilage degeneration of knee

    International Nuclear Information System (INIS)

    Dai Jingru; Dai Shipeng; Pang Jun; Xu Xiaokun; Wang Yuexin; Zhang Zhigang

    2008-01-01

    Objective: To study the appearance of MR diffusion weighted imaging in early stages of cartilage degeneration and to detect its values. Methods: In 20 goat left knees, intra- articular injection of 5 units of papain was performed causing a loss of cartilage proteoglycan. Twenty right knees were used as control group. MR diffusion weighted imaging was performed at 24 hours after intra-articular injection of papain. ADC of each part of articular cartilage was measured and compared with each other. The proteoglycan content was measured biochemically and histochemically. Routine MRI and DWI were performed in 100 patients with osteoarthritis and 20 healthy people. The ADC of each interested part of articular cartilage was measured and compared with each other. Results: In experimental control group, the ADCav of articular cartilage was (14.2±2.3) x 10 -4 mm 2 /s. In early stages of cartilage degeneration group, the ADCav of articular cartilage was (17.5±4.2) x 10 -4 mm 2 /s. The ADCav of the control group was lower than that of the early stages of cartilage degeneration group (t=2.709; P=0.016). The proteloglycan content of articular cartilage was 4.22 x 10 6 μg/kg in control group, and 0.82 x 10 6 μg/kg in experimental group at 24 hours after injection of papain. The difference between control group and experimental group was significant (t=2.705, P=0.018). In healthy people, the ADCav of articular cartilage was (7.6±2.2) x 10 -4 mm 2 /s. In osteoarthritis group, the ADCav of articular cartilage was (10.3±4.2) x 10 -4 mm 2 /s. The ADCav in the healthy group was significantly lower than that in the osteoarthritis group (t=2.609,P=0.014). Conclusion: DWI is an useful method in detecting early stages of cartilage degeneration which can not be showed on routine sequences. (authors)

  12. Transient Splenial Lesion of Corpus Callosum Associated with Antiepileptic Drug: Conventional and Diffusion-weighted Magnetic Resonance Images

    International Nuclear Information System (INIS)

    Hakyemez, B.; Erdogan, C.; Yildirim, N.; Gokalp, G.; Parlak, M.

    2005-01-01

    Transient focal lesions of splenium of corpus callosum can be seen as a component of many central nervous system diseases, including antiepileptic drug toxicity. The conventional magnetic resonance (MR) findings of the disease are characteristic and include ovoid lesions with high signal intensity at T2-weighted MRI. Limited information exists about the diffusion-weighted MRI characteristics of these lesions vanishing completely after a period of time. We examined the conventional, FLAIR, and diffusion-weighted MR images of a patient complaining of depressive mood and anxiety disorder after 1 year receiving antiepileptic medication

  13. Transient Splenial Lesion of Corpus Callosum Associated with Antiepileptic Drug: Conventional and Diffusion-weighted Magnetic Resonance Images

    Energy Technology Data Exchange (ETDEWEB)

    Hakyemez, B.; Erdogan, C.; Yildirim, N.; Gokalp, G.; Parlak, M. [Uludag Univ. Medical School, Bursa (Turkey). Dept. of Radiology

    2005-11-01

    Transient focal lesions of splenium of corpus callosum can be seen as a component of many central nervous system diseases, including antiepileptic drug toxicity. The conventional magnetic resonance (MR) findings of the disease are characteristic and include ovoid lesions with high signal intensity at T2-weighted MRI. Limited information exists about the diffusion-weighted MRI characteristics of these lesions vanishing completely after a period of time. We examined the conventional, FLAIR, and diffusion-weighted MR images of a patient complaining of depressive mood and anxiety disorder after 1 year receiving antiepileptic medication.

  14. Prognostic value of perfusion- and diffusion-weighted MR imaging in first 3 days of stroke

    International Nuclear Information System (INIS)

    Kluytmans, M.; Everdingen, K.J. van; Ramos, L.M.P.; Viergever, M.A.; Grond, J. van der; Kappelle, L.J.

    2000-01-01

    The aim of this study was to evaluate the differences in cerebral perfusion seen on mean transit time (MTT) and cerebral blood volume (CBV) maps and to assess the subsequent prognostic value of the MTT-DWI (diffusion-weighted MRI) and CBV-DWI mismatch in the first three days of stroke on lesion enlargement and clinical outcome. In 38 patients, imaged 1-46 h after onset of symptoms, lesion volumes on proton-density (PD)-weighted MRI, DWI and PWI (both MTT and CBV maps) were compared with lesion volumes on follow-up PD-weighted scans, and to clinical outcome (National Institutes of Health Stroke Scale, Barthel index, and Rankin scale). The MTT-CBV, MTT-DWI and CBV-DWI mismatches were compared with change in lesion volume between initial and follow-up PD-weighted scans. Lesion volume on both DWI and PWI correlated significantly with clinical outcome parameters (p < 0.001) with strongest correlation for lesion volume on CBV. Perfusion-diffusion mismatches were found for both CBV and MTT and correlated significantly with lesion enlargement on PD-weighted imaging with strongest correlation for the CBV-DWI mismatch. The CBV-DWI mismatch has the highest accuracy in predicting lesion size on follow-up imaging and in predicting clinical outcome. Lesion volume measurements on CBV maps have a higher specificity than on PD-weighted, MTT or DWI images in predicting clinical follow-up imaging and in predicting clinical outcome. (orig.)

  15. Respiratory syncytial virus-related encephalitis: magnetic resonance imaging findings with diffusion-weighted study

    Energy Technology Data Exchange (ETDEWEB)

    Park, Arim; Suh, Sang-il; Seol, Hae-Young [Korea University College of Medicine, Department of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Son, Gyu-Ri; Lee, Nam-Joon [Korea University College of Medicine, Department of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Lee, Young Hen; Seo, Hyung Suk [Korea University College of Medicine, Department of Radiology, Korea University Ansan Hospital, Gyeonggi-do (Korea, Republic of); Eun, Baik-Lin [Korea University College of Medicine, Department of Pediatrics, Korea University Guro Hospital, Seoul (Korea, Republic of)

    2014-02-15

    Respiratory syncytial virus (RSV) is a common pathogen causing acute respiratory infection in children. Herein, we describe the incidence and clinical and magnetic resonance imaging (MRI) findings of RSV-related encephalitis, a major neurological complication of RSV infection. We retrospectively reviewed the medical records and imaging findings of the patients over the past 7 years who are admitted to our medical center and are tested positive for RSV-RNA by reverse transcriptase PCR. In total, 3,856 patients were diagnosed with RSV bronchiolitis, and 28 of them underwent brain MRI for the evaluation of neurologic symptoms; 8 of these 28 patients had positive imaging findings. Five of these 8 patients were excluded because of non-RSV-related pathologies, such as subdural hemorrhage, brain volume loss due to status epilepticus, periventricular leukomalacia, preexisting ventriculomegaly, and hypoxic brain injury. The incidence of RSV-related encephalitis was as follows: 3/3,856 (0.08 %) of the patients are positive for RSV RNA, 3/28 (10.7 %) of the patient underwent brain MRI for neurological symptom, and 3/8 (37.5 %) of patients revealed abnormal MR findings. The imaging findings were suggestive of patterns of rhombenmesencephalitis, encephalitis with acute disseminated encephalomyelitis, and limbic encephalitis. They demonstrated no diffusion abnormality on diffusion-weighted image and symptom improvement on the follow-up study. Encephalitis with RSV bronchiolitis occurs rarely. However, on brain MRI performed upon suspicion of neurologic involvement, RSV encephalitis is not infrequently observed among the abnormal MR findings and may mimic other viral and limbic encephalitis. Physicians should be aware of this entity to ensure proper diagnosis and neurologic care of RSV-positive patients. (orig.)

  16. Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fonte, Mariana Vieira de Melo da; Otaduy, Maria Concepcion Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Leite, Claudia da Costa [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Inst. de Radiologia]. E-mail: mvmfonte@uol.com.br; Costa, Maria Olivia Rodrigues; Amaral, Raquel Portugal Guimaraes [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Dept. de Radiologia; Reed, Umbertina Conti [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Dept. de Neurologia; Rosemberg, Sergio [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Dept. de Patologia

    2008-11-15

    To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, considering demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T 1-weighted images and intermediate/hyperintense on T 2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Na a / Cr ratio (83.3%) and increased Co/Cr (100%) and ml/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors. (author)

  17. Medulloblastoma: correlation among findings of conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Fonte, Mariana Vieira de Melo da; Otaduy, Maria Concepcion Garcia; Lucato, Leandro Tavares; Reed, Umbertina Conti; Leite, Claudia da Costa; Costa, Maria Olivia Rodrigues; Amaral, Raquel Portugal Guimaraes; Reed, Umbertina Conti; Rosemberg, Sergio

    2008-01-01

    To correlate imaging findings of medulloblastomas at conventional magnetic resonance imaging, diffusion-weighted imaging and proton magnetic resonance spectroscopy, comparing them with data in the literature. Preoperative magnetic resonance imaging studies of nine pediatric patients with histologically confirmed medulloblastomas (eight desmoplastic medulloblastoma, and one giant cell medulloblastoma) were retrospectively reviewed, considering demographics as well as tumors characteristics such as localization, morphology, signal intensity, contrast-enhancement, dissemination, and diffusion-weighted imaging and spectroscopy findings. In most of cases the tumors were centered in the cerebellar vermis (77.8%), predominantly solid (88.9%), hypointense on T 1-weighted images and intermediate/hyperintense on T 2-FLAIR-weighted images, with heterogeneous enhancement (100%), tumor dissemination/extension (77.8%) and limited water molecule mobility (100%). Proton spectroscopy acquired with STEAM technique (n = 6) demonstrated decreased Na a / Cr ratio (83.3%) and increased Co/Cr (100%) and ml/Cr (66.7%) ratios; and with PRESS technique (n = 7) demonstrated lactate peak (57.1%). Macroscopic magnetic resonance imaging findings in association with biochemical features of medulloblastomas have been useful in the differentiation among the most frequent posterior fossa tumors. (author)

  18. Assessment of the link between quantitative biexponential diffusion-weighted imaging and contrast-enhanced MRI in the liver

    NARCIS (Netherlands)

    Dijkstra, Hildebrand; Oudkerk, Matthijs; Kappert, Peter; Sijens, Paul E.

    Purpose: To investigate if intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) can be linked to contrast-enhanced (CE-)MRI in liver parenchyma and liver lesions. Methods: Twenty-five patients underwent IVIM-DWI followed by multiphase CE-MRI using Gd-EOB-DTPA (n = 20) or

  19. Quantitative evaluation of brain involvement in ataxia telangiectasia by diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Firat, Ahmet Kemal; Karakas, Hakki Muammer; Firat, Yezdan; Yakinci, Cengiz

    2005-01-01

    Objective: To evaluate the value of diffusion weighted imaging (DWI) in diagnosing ataxia telangiectasia (AT) and to investigate the spatial distribution of cerebral microstructural changes caused by the disease. Methods: Six AT patients (9-13 years) and nine healthy control subjects were examined on 1.5 T scanner. In addition to conventional MR images, DWI were performed with a fat suppressed, multishot spin echo EPI sequence using B values of 0, 500 and 1000 s/mm 2 . Mean ADC values were measured from 16 different supra and infratentorial location. The difference between controls and AT patients regarding ADC values, and the accuracy, sensitivity and specificity of them in discrimination were analyzed with t-tests, logistic regression analysis, ANOVA and ROC curves. Results: Conventional images of the controls were normal. In AT patients, the only conventional MR abnormality was cerebellar atrophy. The difference between both groups regarding mean ADC values was not significant for any of the cerebral structures. In contrary to cerebrum, cerebellar mean ADC values of patients and controls were statistically different (p 2 /s) for middle cerebellar cortex had produced highest (100%) sensitivity and specificity. There was a difference between superior, middle and inferior cerebellar cortex regarding ADC values (p 2 /s) had higher ADC values than the middle and inferior cerebellar cortex. Conclusion: DWI provides a supplementary and objective imaging finding in AT. This finding is highly accurate in the radiological discrimination of healthy subjects and AT. Our findings also implicate that AT causes a diffuse atrophy and mostly affects superior part of the cortex

  20. Added value of diffusion weighted imaging in pediatric central nervous system embryonal tumors surveillance

    Science.gov (United States)

    Tortora, Domenico; Severino, Mariasavina; Nozza, Paolo; Cama, Armando; Ravegnani, Marcello; D'Apolito, Gabriella; Raso, Alessandro; Milanaccio, Claudia; da Costa Leite, Claudia; Garrè, Maria Luisa; Rossi, Andrea

    2017-01-01

    Diffusion weighted imaging (DWI) has an established role in primary CNS embryonal tumor (ET) characterization; however, its diagnostic utility in detecting relapse has never been determined. We aimed to compare DWI and conventional MRI sensitivity in CNS ET recurrence detection, and to evaluate the DWI properties of contrast-enhancing radiation induced lesions (RIL). Fifty-six patients with CNS ET (25 with disease relapse, 6 with RIL and 25 with neither disease relapse nor RIL) were retrospectively evaluated with DWI, conventional MRI (including both T2/FLAIR and post-contrast images), or contrast-enhanced MR imaging (CE-MRI) alone. MRI studies were independently reviewed by two neuroradiologists for detection and localization of potential brain relapses. Sensitivity for focal relapse detection was calculated for each image set on a lesion-by-lesion basis. A descriptive per subject analysis was also performed. Evaluation of follow-up MRI studies served as standard of reference. Focal recurrence detection sensitivity of DWI (96%) was significantly higher than conventional MRI (77%) and CE-MRI alone (51%) (p=0.0003 and p<0.0001). On per subject analysis there were not missed diagnoses for DWI. At the time of DWI relapse detection, conventional MRI missed 2 diagnoses, and CE-MRI 8. Analysis of medulloblastoma relapses revealed that DWI identified a higher number of focal lesions than CE-MRI in subjects with classic variant. All but one RIL did not show restricted diffusion. In conclusion, DWI is a valuable complementary technique allowing for improved detection of focal relapse in CNS ET patients, particularly in children with classic medulloblastoma, and may assist in differentiating recurrence from RIL. PMID:28947980

  1. MR elastography and diffusion-weighted imaging of ex vivo prostate cancer: quantitative comparison to histopathology.

    Science.gov (United States)

    Sahebjavaher, Ramin S; Nir, Guy; Gagnon, Louis O; Ischia, Joseph; Jones, Edward C; Chang, Silvia D; Yung, Andrew; Honarvar, Mohammad; Fazli, Ladan; Goldenberg, S Larry; Rohling, Robert; Sinkus, Ralph; Kozlowski, Piotr; Salcudean, Septimiu E

    2015-01-01

    The purpose of this work was (1) to develop a magnetic resonance elastography (MRE) system for imaging of the ex vivo human prostate and (2) to assess the diagnostic power of mono-frequency and multi-frequency MRE and diffusion weighted imaging (DWI) alone and combined as correlated with histopathology in a patient study. An electromagnetic driver was designed specifically for MRE studies in small-bore MR scanners. Ex vivo prostate specimens (post-fixation) of 14 patients who underwent radical prostatectomy were imaged with MRE at 7 T (nine cases had DWI). In six patients, the MRE examination was performed at three frequencies (600, 800, 1000 Hz) to extract the power-law exponent Gamma. The images were registered to wholemount pathology slides marked with the Gleason score. The areas under the receiver-operator-characteristic curves (AUC) were calculated. The methods were validated in a phantom study and it was demonstrated that (i) the driver does not interfere with the acquisition process and (ii) the driver can generate amplitudes greater than 100 µm for frequencies less than 1 kHz. In the quantitative study, cancerous tissue with Gleason score at least 3 + 3 was distinguished from normal tissue in the peripheral zone (PZ) with an average AUC of 0.75 (Gd ), 0.75 (Gl ), 0.70 (Gamma-Gd ), 0.68 (apparent diffusion coefficient, ADC), and 0.82 (Gd  + Gl  + ADC). The differentiation between PZ and central gland was modest for Gd (p analysis did not appear to improve the results. However, in light of the effect of tissue fixation, the clinical implication of our results may be inconclusive and more experiments are needed. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Diffusion-weighted imaging in the diagnosis of enterovirus 71 encephalitis

    International Nuclear Information System (INIS)

    Lian, Zhou-yang; Huang, Biao; Liang, Chang-hong; He, Shaoru; Guo, Yuxiong

    2012-01-01

    Background. In the early phase of viral encephalitis, conventional MRI may appear normal. Diffusion-weighted imaging (DWI) is a sensitive tool for detecting early changes in cellular function in the central nervous system. Purpose. To investigate the usefulness of DWI in the diagnosis of enterovirus 71 (EV71) encephalitis, and to determine whether DWI is superior to conventional MR sequences. Material and Methods. MRI scans in 26 patients were retrospectively evaluated for distribution of lesions on T1-weighted images (T1WI), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and DWI. Contrast-to-noise ratios (CNRs) were calculated for all regions on each sequence and differences in the four MRI sequences were assessed using CNRs. Apparent diffusion coefficient (ADC) values were measured for all regions to look for true restriction of diffusion. Results. Fifteen out of 26 cases showed positive findings on MR imaging. The brain stem was involved in 11 patients, cortex and subcortical white matter in four patients. DWI was more sensitive in detecting the abnormalities (89.7%) compared to T2WI (48.7%), FLAIR (41.0%), and T1WI (35.9%), and the positive ratio of DWI was significantly higher compared to other sequences. Furthermore, no significant difference was found between T2WI and FLAIR (P 0.649). The corresponding mean CNRs were 8.73 ± 2.57, 83.59 ± 29.28, 24.22 ± 6.22, and 132.27 ± 78.32 on T1WI, T2WI, FLAIR, and DWI, respectively. The absolute values of CNRs of lesions on DWI were significantly greater than those on other sequences. Conclusion. DWI appears to be more sensitive in detecting EV71 encephalitis than conventional MRI sequences. This capability may improve the accuracy in diagnosing EV71 encephalitis, especially at the early stage

  3. Diffusion-weighted imaging in the diagnosis of enterovirus 71 encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Lian, Zhou-yang; Huang, Biao; Liang, Chang-hong (Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)), Email: cjr.huangbiao@vip.163.com; He, Shaoru; Guo, Yuxiong (Department of Pediatrics, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China))

    2012-03-15

    Background. In the early phase of viral encephalitis, conventional MRI may appear normal. Diffusion-weighted imaging (DWI) is a sensitive tool for detecting early changes in cellular function in the central nervous system. Purpose. To investigate the usefulness of DWI in the diagnosis of enterovirus 71 (EV71) encephalitis, and to determine whether DWI is superior to conventional MR sequences. Material and Methods. MRI scans in 26 patients were retrospectively evaluated for distribution of lesions on T1-weighted images (T1WI), T2-weighted images (T2WI), fluid-attenuated inversion recovery (FLAIR), and DWI. Contrast-to-noise ratios (CNRs) were calculated for all regions on each sequence and differences in the four MRI sequences were assessed using CNRs. Apparent diffusion coefficient (ADC) values were measured for all regions to look for true restriction of diffusion. Results. Fifteen out of 26 cases showed positive findings on MR imaging. The brain stem was involved in 11 patients, cortex and subcortical white matter in four patients. DWI was more sensitive in detecting the abnormalities (89.7%) compared to T2WI (48.7%), FLAIR (41.0%), and T1WI (35.9%), and the positive ratio of DWI was significantly higher compared to other sequences. Furthermore, no significant difference was found between T2WI and FLAIR (P 0.649). The corresponding mean CNRs were 8.73 +- 2.57, 83.59 +- 29.28, 24.22 +- 6.22, and 132.27 +- 78.32 on T1WI, T2WI, FLAIR, and DWI, respectively. The absolute values of CNRs of lesions on DWI were significantly greater than those on other sequences. Conclusion. DWI appears to be more sensitive in detecting EV71 encephalitis than conventional MRI sequences. This capability may improve the accuracy in diagnosing EV71 encephalitis, especially at the early stage

  4. Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

    International Nuclear Information System (INIS)

    Messiou, C.; Collins, D.J.; Morgan, V.A.; DeSouza, N.M.

    2011-01-01

    To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelomatous involvement, to establish reproducibility and to optimise b values. The ADCs of bone marrow in 7 volunteers (mean age 29.7 years), 34 volunteers (mean age 63.3 years) and 43 patients with metastatic and myelomatous involvement (mean age 65.5 years) were measured. In 9 volunteers diffusion weighted MRI was repeated within 7 days. b values were derived to optimise contrast between normal and pathological marrow. The mean ADC of bone marrow in younger volunteers was significantly higher than that of older volunteers. The coefficient of reproducibility was 14.8%. The ADC mean of metastatic and myeloma bone disease was 1054+/-456 x 10 -6 mm 2 s -1 . An ADC threshold of 655 x 10 -6 mm 2 s -1 separated normal and abnormal marrow with a sensitivity and specificity of 90% and 93% respectively. Contrast between normal and abnormal marrow was optimal at b = 1389 smm -2 . The reproducibility of ADC measurements in bone is equivalent to published data for soft tissue with a high sensitivity and specificity for separating abnormal from age matched normal bone marrow. A b value of around 1,400 smm -2 is optimal for imaging bone marrow. (orig.)

  5. Utility of diffusion-weighted imaging in the diagnosis of acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Inci, Ercan; Hocaoglu, Elif; Aydin, Sibel; Bayramoglu, Sibel; Cimilli, Tan [Bakirkoy Dr. Sadi Konuk Training and Research Hospital, Department of Radiology, Istanbul (Turkey); Kilickesmez, Ozgur [Yeditepe University, School of Medicine, Department of Radiology, Istanbul (Turkey)

    2011-04-15

    To evaluate the value of diffusion-weighted MRI (DWI) in the diagnosis of acute appendicitis. 119 patients with acute appendicitis and 50 controls were enrolled in this prospective study. DWI was obtained with b factors 0, 500 and 1000 s/mm{sup 2} and were assessed with a visual scoring system by two radiologists followed by quantitative evaluation of the DW images and ADC maps. Histopathology revealed appendicitis in 79/92 patients (78%) who had undergone surgery. On visual evaluation, except for one patient with histopathologically proven appendicitis all inflamed appendixes were hyperintense on DWI (98.7%). Quantitative evaluation with DW signal intensities and ADC values revealed a significant difference with normal and inflamed appendixes (p < 0.001). The best discriminative parameter was signal intensity (b 500). With a cut-off value of 56 for the signal intensity the ratio had a sensitivity of 99% and a specificity of 97%. The cut-off ADC value at 1.66 mm{sup 2}/s had a sensitivity of 97% and a specificity of 99%. DWI is a valuable technique for the diagnosis of acute appendicitis with both qualitative and quantitative evaluation. DWI increases the conspicuity of the inflamed appendix. We recommend using DWI to diagnose acute appendicitis. (orig.)

  6. Diffusion-weighted imaging of the kidneys in haemolytic uraemic syndrome

    International Nuclear Information System (INIS)

    Herrmann, Jochen; Wenzel, Ulrich; Galler, Stephanie; Schoennagel, Bjoern P.; Bannas, Peter; Yamamura, Jin; Groth, Michael; Adam, Gerhard; Busch, Jasmin D.; Tozakidou, Magdalini; Petersen, Kay U.; Joekel, Michaela; Habermann, Christian R.

    2017-01-01

    To evaluate the kidneys of patients with haemolytic uraemic syndrome (HUS) using diffusion-weighted imaging (DWI) and Doppler ultrasound (US) compared with healthy controls. Fifteen patients (mean age 33.3 years; three male; 12 female) with diarrhoea-positive HUS and 15 healthy volunteers were prospectively evaluated with DWI and Doppler US. A total apparent diffusion coefficient (ADC TOT ), and ADCs predominantly reflecting microperfusion (ADC LOW ) and diffusion (ADC HIGH ) were calculated. Doppler US evaluated renal vascularity and flow. When compared with controls, kidneys affected by HUS showed reduced cortical ADC values (ADC TOT 1.79±0.22 vs. 2.04±0.1x10 -3 mm 2 /s, P 0.001), resulting in either low corticomedullary differences (11/15 patients) or an inverted corticomedullary pattern (4/15 patients). Reduction of cortical ADC values was associated with a decrease of cortical vascularity on Doppler US (ADC TOT , P<0.001; ADC LOW , P 0.047). Kidneys with complete absence of the cortical vasculature on Doppler US (four patients) also demonstrated limited diffusion (ADC HIGH , P 0.002). Low glomerular filtration rate, requirement for haemodialysis during hospitalization, and longer duration of haemodialysis were associated with decreased cortical diffusivity (ADC TOT: P 0.04, 0.007, and <0.001, respectively). DWI shows qualitative and quantitative abnormalities in kidneys affected by HUS, thereby extending the non-invasive assessment of renal parenchymal damage. (orig.)

  7. Clinico-radiological features of subarachnoid hyperintensity on diffusion-weighted images in patients with meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, T., E-mail: madarafuebuki@yahoo.co.jp [Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya (Japan); Sakurai, K.; Hara, M. [Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya (Japan); Muto, M. [Department of Radiology, Okazaki City Hospital, Okazaki, Aichi (Japan); Nakagawa, M. [Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya (Japan); Tohyama, J. [Department of Radiology, Toyota-kai Medical Corporation Kariya Toyota General Hospital, Kariya, Aichi (Japan); Oguri, T. [Department of Neurology and Neuroscience, Nagoya City University Graduate School of Medical Sciences, Nagoya (Japan); Mitake, S. [Department of Neurology, Tosei General Hospital, Seto-shi, Aichi (Japan); Maeda, M. [Department of Radiology, Mie University School of Medicine, Tsu, Mie (Japan); Matsukawa, N.; Ojika, K. [Department of Neurology and Neuroscience, Nagoya City University Graduate School of Medical Sciences, Nagoya (Japan); Shibamoto, Y. [Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya (Japan)

    2012-04-15

    Aim: To investigate the clinical and radiological features of meningitis with subarachnoid diffusion-weighted imaging (DWI) hyperintensity. Materials and methods: The clinical features, laboratory data, and radiological findings, including the number and distribution of subarachnoid DWI hyperintense lesions and other radiological abnormalities, of 18 patients seen at five institutions were evaluated. Results: The patients consisted of eight males and 10 females, whose ages ranged from 4 months to 82 years (median 65 years). Causative organisms were bacteria in 15 patients, including Haemophilus influenzae, Streptococcus pneumoniae, Streptococcus agalactiae, Staphylococcus aureus, Klebsiella pneumoniae, and Listeria monocytogenes. The remaining three were fungal meningitis caused by Cryptococcus neoformans. Subarachnoid DWI hyperintense lesions were multiple in 16 of the 18 cases (89%) and predominantly distributed around the frontal lobe in 16 of the 18 cases (89%). In addition to subarachnoid abnormality, subdural empyema, cerebral infarction, and intraventricular empyema were found in 50, 39, and 39%, respectively. Compared with paediatric patients, adult patients with bacterial meningitis tended to have poor prognoses (7/10 versus 1/5; p = 0.1). Conclusion: Both bacterial and fungal meningitis could cause subarachnoid hyperintensity on DWI, predominantly around the frontal lobe. This finding is often associated with poor prognosis in adult bacterial meningitis.

  8. Value of diffusion-Weighted imaging in evaluating the cellularity density of prostate cancer

    International Nuclear Information System (INIS)

    Liu Jingang; Wang Xizhen; Wang Bin; Niu Qingliang; Liu Qiang

    2008-01-01

    Objective: To study the cellularity density of prostate cancer (PCa) with diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC). Methods: 38 patients with histologically proven prostate cancer (PCa) underwent DWI with a 1.5 T MR scanner using a pelvic phased array multi-coil. The ADC values of PCa, benign prostatic hyperplasia (BPH), and peripheral zone (PZ) were calculated. The cellularity density of PCa was recorded according to hematoxylin and eosin (HE) staining. The relationship between ADC value and cellularity density of PCa was analyzed with Pearson correlation coefficient. Results: The ADC values of PCa, BPH, and PZ were (49.32±12.68)×10 -5 mm 2 /s, (86.73±26.75)×10 -5 mm 2 /s and (126.25±27.21)×10 -5 mm 2 /s, respectively. The ADC value of PCa was significantly lower than that of BPH and PZ (P<005). The cellularity density of PCa was 12.9%. The ADC value reversely related to the cellularity density of prostate cancer (r=-0.646, P<005). Conclusion: The ADC value can reflect the cellularity density of PCa. (authors)

  9. Evaluation of diffusion weighted imaging in differentiating prostate cancer and benign hyperplasia

    International Nuclear Information System (INIS)

    Wang Ximing; Guo Liang; Zhang Yu; Bai Renju; Zhao Xin

    2006-01-01

    Objective: To describe diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC) map appearance of benign hyperplasia (BPH) and prostate cancer(PCa), and to evaluate DWI and ADC map and ADC values in differential diagnosis of PCa. Methods: DWI and ADC map findings were reviewed in 18 BPH cases and 25 PCa cases. ADC values of PCa and ADC values of peripheral zone (PZ) and central glands (CG) voxels in BPH were retrospectively measured. Results: On DWI, PZ of BPH demonstrated homogenous slightly signal intensity (SI), CG appeared heterogeneous SI. Twenty-two PCa showed markedly high-signal on DWI and obviously low-signal on ADC map, which both could clearly demonstrate the area of PCa. The invaded seminal vesicles and bone metastases of pelvis also appear similar SI as PCa on DWI and ADC map. ADC values of PCa were significantly lower than PZ(t=-52.46, P -3 mm 2 /s] and PZ in BPH [(1.27±0.14) x 10 -3 mm 2 /s], only minimal overlap (1/127, 0.7%) existed between ADC values of PCa and CG in BPH[(0.96±0.14) x 10 -3 mm 2 /s]. Conclusion: Both DWI and ADC map can well display PCa location and area, which also can show the involvement of seminal vesicles and bone metastases. BPH and PCa can be differentiated by Both DWI and ADC map and ADC values. (authors)

  10. High b-value diffusion-weighted imaging in progressive multifocal leukoencephalopathy in HIV patients

    International Nuclear Information System (INIS)

    Godi, Claudia; De Vita, Enrico; Davagnanam, Indran; Tombetti, Enrico; Haddow, Lewis; Jaeger, Hans Rolf

    2017-01-01

    An ill-defined hyperintense edge and hypointense core on diffusion-weighted imaging (DWI) is typical of progressive multifocal leukoencephalopathy (PML). We aimed to investigate whether a b-value of 3,000 s/mm 2 (b3000) can improve visualisation of PML, or provide different structural information compared to 1,000 s/mm 2 (b1000). We retrospectively identified HIV-positive patients with confirmed PML studied under a clinical protocol including both b1000 and b3000 DWI. The rim and core of each PML lesion and normal-appearing white matter (NAWM) were outlined on trace-weighted DWI. Signal intensities, apparent diffusion coefficient (ADC) values and volumes were measured and compared between b1000 and b3000. Nine lesions from seven patients were analysed. The rim and core were better visualised on b3000, with higher signal of the rim and lower signal of the core compared to NAWM. The hyperintense rim had non-restricted average ADCs, but included foci of low ADC on both b3000 and b1000. Despite similar total lesion volumes, b3000 displayed significantly larger core and smaller rim volumes than b1000. b3000 improves visualisation of this important PML hallmark. Moreover, b3000 partly reclassifies tissue from rim into core, and might provide potentially more accurate biomarkers of PML activity and prognosis. (orig.)

  11. Optimization of MR diffusion-weighted imaging acquisitions for pancreatic cancer at 3.0T.

    Science.gov (United States)

    Yao, Xiuzhong; Kuang, Tiantao; Wu, Li; Feng, Hao; Liu, Hao; Cheng, Weizhong; Rao, Shengxiang; Wang, He; Zeng, Mengsu

    2014-09-01

    To investigate and optimize diffusion-weighted imaging (DWI) acquisitions for pancreatic cancer at 3.0T. Forty-five patients with pancreatic cancer were examined by four DWI acquisitions with b values=0 and 600s/mm(2) at 3.0T, including breath-holding DWI (BH-DWI), respiratory-triggered DWI (TRIG-DWI), respiratory-triggered DWI with inversion-recovery technique (TRIGIR-DWI), and free-breathing DWI with inversion-recovery technique (FBIR-DWI). Artifacts, contrast ratio (CR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of pancreatic cancer were statistically compared among DWI acquisitions. TRIGIR-DWI displayed the lowest artifacts and highest CR compared to other DWI acquisitions. CNRs of pancreatic cancer in TRIG-DWI and TRIGIR-DWI were statistically higher than that in FBIR-DWI and BH-DWI. Different ADCs between pancreatic cancer and noncancerous pancreatic tissues were noticed by a paired-samples T test in TRIG-DWI (p=0.017), TRIGIR-DWI (p=0.00001) and FBIR-DWI (p=0.000041). TRIGIR-DWI may be the optimal acquisition of DWI for pancreatic cancer at 3.0T. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Comparison of breast cancer detection by diffusion-weighted magnetic resonance imaging and mammography

    International Nuclear Information System (INIS)

    Yoshikawa, Miho I.; Kikuchi, Keiichi; Mochizuki, Teruhito; Ohsumi, Shozo; Sugata, Shigenori; Kataoka, Masaaki; Takashima, Shigemitsu

    2007-01-01

    Breast cancer-detecting ability of diffusion-weighted magnetic resonance imaging (DW-MRI) was investigated by comparing the breast cancer detection rates of DW-MRI and mammography (MMG). The subjects were 48 women who had breast cancer (53 cancer lesions) who underwent DW-MRI before surgery. Altogether, 41 lesions were invasive ductal carcinoma (IDC), 7 were noninvasive ductal carcinoma (NIDC) and 5 were ''others.'' The breast cancer detection rates by MMG and DW-MRI were 84.9% and 94.3% (P -3 , 1.50±0.24 x 10 -3 , 1.12±0.25 x 10 -3 , and 2.01±0.29 x 10 -3 mm 2 /s for IDC, NIDC, others, and normal breast, respectively, showing that the values of IDC and NIDC were significantly different from that of the normal breast (P<0.001 each). A significant difference was also noted between IDC and NIDC (P<0.001). DW-MRI may be useful for detecting breast cancer in a wide age group of women, including young women with dense mammary glands. (author)

  13. Diffusion-Weighted Magnetic Resonance Imaging of Cerebrospinal Fluid in Patients with and without Communicating Hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Nasel, C.; Gentzsch, S.; Heimberger, K. [Cerebrovascular Imaging Workgroup of the Div. of Neuroradiology, Dept. of Radiology, Medical Univ. Vienna, Vienna (Austria)

    2007-09-15

    Background: Recent concepts about cerebrospinal fluid (CSF) circulation in communicating hydrocephalus (CoHy), which is also termed 'restricted arterial pulsation hydrocephalus,' suggest reduced arterial pulsations of subarachnoid vessels with a smaller amount of CSF shifted in subarachnoid spaces during the early systole. The postulated restriction of subarachnoid arterial pulsations in CoHy should induce a smaller motion artifact and reduced local stream effects in CSF in magnetic resonance (MR) diffusion-weighted imaging (DWI). Purpose: To investigate the maximum diffusivity in CSF in patients with and without CoHy using DWI. Material and Methods: 12 patients without CSF circulation disturbances and six cases with proven CoHy were assessed. Diffusion was measured in six non collinear directions without triggering the arterial pulse wave (scan time 6:45 min, voxel size 2x2x2 mm). Due to expected artifacts, the calculated maximum diffusivity was called apparent diffusivity. Regional high and low apparent diffusivity was assessed in CSF spaces on newly created 3D CSF motion maps. Results: Patients with regular CSF circulation exhibited high apparent diffusivity in CSF in basal subarachnoid spaces, whereas apparent diffusivity was low there in patients with CoHy. Conclusion: DWI opens a feasible approach to study CSF motion in the neurocranium. Restricted arterial pulsations seem to be involved in CoHy.

  14. The role of diffusion weighted MR imaging for differentiation between Graves' disease and Hashimoto thyroiditis.

    Science.gov (United States)

    Ozturk, T; Bozgeyik, Z; Ozturk, F; Burakgazi, G; Akyol, M; Coskun, S; Ozkan, Y; Ogur, E

    2015-08-01

    The aim of this study was to evaluate the usefulness of diffusion-weighted magnetic resonance imaging (DWMRI) for differentation between Graves' disease and Hashimoto's thyroiditis. Fifty patients (27 Graves diseases and 23 Hashimoto thyroiditis) and twenty healthy volunteers were examined using T1, T2 and DWMRI. The patients were diagnosed on the basis of physical findings and the results of thyroid function tests and serological tests. Circular ROIs were positioned on the bilateral thyroid lobes and isthmus. All measurements were repeated three different b values including 100, 600 and 1000 s/mm2 in all cases. ADC (Apparent diffusion coefficient) maps were calculated automatically with the MR system. Mean ADC values were 2.93 × 10-3, 1.97 × 10-3 and 1.62 × 10-3 mm2/s in the healthy volunteers; 3.47 × 10-3, 2.25 × 10-3 and 1.64 × 10-3 mm2/s in Graves' disease; 2.53 × 10-3, 1.76 × 10-3, 1.28 × 10-3 mm2/s in Hashimoto thyroiditis for b100, b600 and b1000, respectively. The ADC values of the Graves diseases were higher than healty volunteers and Hashimoto thyroiditis. ADC values were statistically significant for differentation between Hashimoto thyroiditis and Graves' disease all b values (p Hashimoto thyroiditis and Graves' disease.

  15. High b-value diffusion-weighted imaging in progressive multifocal leukoencephalopathy in HIV patients

    Energy Technology Data Exchange (ETDEWEB)

    Godi, Claudia [San Raffaele Scientific Institute, Neuroradiology Department, Milan (Italy); The National Hospital for Neurology and Neurosurgery, Lysholm Department of Neuroradiology, London (United Kingdom); UCL Institute of Neurology, Neuroradiological Academic Unit, Department of Brain Repair and Rehabilitation, London (United Kingdom); De Vita, Enrico; Davagnanam, Indran [The National Hospital for Neurology and Neurosurgery, Lysholm Department of Neuroradiology, London (United Kingdom); UCL Institute of Neurology, Neuroradiological Academic Unit, Department of Brain Repair and Rehabilitation, London (United Kingdom); Tombetti, Enrico [Vita-Salute San Raffaele University, Milan (Italy); Haddow, Lewis [University College London, Centre for Sexual Health and HIV Research, Research Department of Infection and Population Health, London (United Kingdom); Jaeger, Hans Rolf [The National Hospital for Neurology and Neurosurgery, Lysholm Department of Neuroradiology, London (United Kingdom); UCL Institute of Neurology, Neuroradiological Academic Unit, Department of Brain Repair and Rehabilitation, London (United Kingdom); University College Hospital, Centre of Medical Imaging, London (United Kingdom)

    2017-09-15

    An ill-defined hyperintense edge and hypointense core on diffusion-weighted imaging (DWI) is typical of progressive multifocal leukoencephalopathy (PML). We aimed to investigate whether a b-value of 3,000 s/mm{sup 2} (b3000) can improve visualisation of PML, or provide different structural information compared to 1,000 s/mm{sup 2} (b1000). We retrospectively identified HIV-positive patients with confirmed PML studied under a clinical protocol including both b1000 and b3000 DWI. The rim and core of each PML lesion and normal-appearing white matter (NAWM) were outlined on trace-weighted DWI. Signal intensities, apparent diffusion coefficient (ADC) values and volumes were measured and compared between b1000 and b3000. Nine lesions from seven patients were analysed. The rim and core were better visualised on b3000, with higher signal of the rim and lower signal of the core compared to NAWM. The hyperintense rim had non-restricted average ADCs, but included foci of low ADC on both b3000 and b1000. Despite similar total lesion volumes, b3000 displayed significantly larger core and smaller rim volumes than b1000. b3000 improves visualisation of this important PML hallmark. Moreover, b3000 partly reclassifies tissue from rim into core, and might provide potentially more accurate biomarkers of PML activity and prognosis. (orig.)

  16. Optimization of b-value distribution for biexponential diffusion-weighted MR imaging of normal prostate.

    Science.gov (United States)

    Jambor, Ivan; Merisaari, Harri; Aronen, Hannu J; Järvinen, Jukka; Saunavaara, Jani; Kauko, Tommi; Borra, Ronald; Pesola, Marko

    2014-05-01

    To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. Optimal b-value distributions for the fit of three parameters (fast diffusion Df, slow diffusion Ds, and fraction of fast diffusion f) were determined using Monte-Carlo simulations. The optimal b-value distribution was calculated using four individual optimization methods. Eight healthy volunteers underwent four repeated 3 Tesla prostate DWI scans using both 16 equally distributed b-values and an optimized b-value distribution obtained from the simulations. The b-value distributions were compared in terms of measurement reliability and repeatability using Shrout-Fleiss analysis. Using low noise levels, the optimal b-value distribution formed three separate clusters at low (0-400 s/mm2), mid-range (650-1200 s/mm2), and high b-values (1700-2000 s/mm2). Higher noise levels resulted into less pronounced clustering of b-values. The clustered optimized b-value distribution demonstrated better measurement reliability and repeatability in Shrout-Fleiss analysis compared with 16 equally distributed b-values. The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments. Copyright © 2013 Wiley Periodicals, Inc.

  17. Acute hyperammonemic encephalopathy with features on diffusion-weighted images: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ja Young; Yu, In Kyu [Dept. of Radiology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2015-02-15

    Acute hyperammonemic encephalopathy is a rare toxic encephalopathy caused by accumulated plasma ammonia. A few literatures are reported about MRI findings of acute hyperammonemic encephalopathy. It is different from the well-known chronic hepatic encephalopathy. The clinical symptom and MRI findings of acute hyperammonemic encephalopathy can be reversible with proper treatment. Acute hepatic encephalopathy involves the cingulate cortex, diffuse cerebral cortices, insula, bilateral thalami on diffusion-weighted imaging (DWI), and fluid-attenuated inversion-recovery. Acute hepatic encephalopathy might mimic hypoxic-ischemic encephalopathy because of their similar predominant involving sites. We experienced 2 cases of acute hyperammonemic encephalopathy consecutively. They showed restricted diffusion at the cingulate cortex, cerebral cortices, insula, and bilateral dorsomedial thalami on DWI. One patient underwent acute fulminant hepatitis A, the other patient with underlying chronic liver disease had acute liver failure due to hepatotoxicity of tuberculosis medication. In this report, we presented the characteristic features of DWI in acute hyperammonemic encephalopathy. In addition, we reviewed articles on MRI findings of acute hyperammonemic encephalopathy.

  18. Clinico-radiological features of subarachnoid hyperintensity on diffusion-weighted images in patients with meningitis

    International Nuclear Information System (INIS)

    Kawaguchi, T.; Sakurai, K.; Hara, M.; Muto, M.; Nakagawa, M.; Tohyama, J.; Oguri, T.; Mitake, S.; Maeda, M.; Matsukawa, N.; Ojika, K.; Shibamoto, Y.

    2012-01-01

    Aim: To investigate the clinical and radiological features of meningitis with subarachnoid diffusion-weighted imaging (DWI) hyperintensity. Materials and methods: The clinical features, laboratory data, and radiological findings, including the number and distribution of subarachnoid DWI hyperintense lesions and other radiological abnormalities, of 18 patients seen at five institutions were evaluated. Results: The patients consisted of eight males and 10 females, whose ages ranged from 4 months to 82 years (median 65 years). Causative organisms were bacteria in 15 patients, including Haemophilus influenzae, Streptococcus pneumoniae, Streptococcus agalactiae, Staphylococcus aureus, Klebsiella pneumoniae, and Listeria monocytogenes. The remaining three were fungal meningitis caused by Cryptococcus neoformans. Subarachnoid DWI hyperintense lesions were multiple in 16 of the 18 cases (89%) and predominantly distributed around the frontal lobe in 16 of the 18 cases (89%). In addition to subarachnoid abnormality, subdural empyema, cerebral infarction, and intraventricular empyema were found in 50, 39, and 39%, respectively. Compared with paediatric patients, adult patients with bacterial meningitis tended to have poor prognoses (7/10 versus 1/5; p = 0.1). Conclusion: Both bacterial and fungal meningitis could cause subarachnoid hyperintensity on DWI, predominantly around the frontal lobe. This finding is often associated with poor prognosis in adult bacterial meningitis.

  19. Is the quantitative Diffusion-Weighted MR Imaging and ADC mapping with b-values of 50, 400, and 800 sec/mm2 a reliable method for evaluation of meniscal tears in the knee?

    International Nuclear Information System (INIS)

    Aydin, H.; Kizilgoz, V.; Hekimoglu, B.

    2011-01-01

    Background: Our aim was to evaluate the efficacy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping with different b-factors in visualisation of meniscal tears. Material/Methods: Seventy-four patients; 30 males and 44 females, 37 left and 37 right knees with meniscal tears were involved in this study. Eleven of them were lateral meniscal tears and 63 - medial meniscal tears. DWI was obtained by 3D-SE Echo-planar Imaging (EPI) in coronal and sagittal planes. ADC mapping was carried out in coronal planes with b-factors of 50, 400, and 800 sec/mm 2 . The statistical analysis of DWI and ADC mapping results was performed with the use of the Fishers test and the chi-square test. Results: 1. For both menisci and 74 tears: DWI revealed 86% sensitivity and 100% specificity (p=0.149) with a positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.09. ADC mapping with b-value of 400 sec/mm 2 had 78% sensitivity, and 100% specificity, with PPV of 1 and NPV of 0.06 (p=0.230). 2. For the lateral meniscal tears: DWI and ADC mapping with b-value of 800, for the medial meniscal tears: DWI and ADC mapping with b-factor of 400 s/mm 2 revealed higher sensitivity and specificity than other methods. Conclusions: Quantitative DWI and ADC mapping, especially with b-factor of 400 sec/mm 2 , may be an alternative to routine MR imaging sequences for the visualisation of meniscal tears in the knee. (authors)

  20. Is diffusion-weighted imaging useful in grading and differentiating histopathological subtypes of meningiomas?

    Energy Technology Data Exchange (ETDEWEB)

    Sanverdi, S. Eser, E-mail: esersanverdi@yahoo.com [Hacettepe University, Faculty of Medicine, Department of Radiology (Turkey); Ozgen, Burce, E-mail: burcem@gmail.com [Hacettepe University, Faculty of Medicine, Department of Radiology (Turkey); Oguz, Kader K., E-mail: karlioguz@yahoo.com [Hacettepe University, Faculty of Medicine, Department of Radiology (Turkey); Mut, Melike, E-mail: melikem@hacettepe.edu.tr [Hacettepe University, Faculty of Medicine, Department of Neurosurgery (Turkey); Dolgun, Anil, E-mail: anilbarak@hacettepe.edu.tr [Hacettepe University, Faculty of Medicine, Biostatistics (Turkey); Soylemezoglu, Figen, E-mail: figensoylemez@yahoo.com [Hacettepe University, Faculty of Medicine, Department of Pathology (Turkey); Cila, Aysenur, E-mail: acila@hacettepe.edu.tr [Hacettepe University, Faculty of Medicine, Department of Radiology (Turkey)

    2012-09-15

    Purpose: Meningiomas are mostly benign, however atypical or malignant subtypes with more aggressive clinical course and higher recurrence rates can also be seen. The purpose of this study was to determine whether histopathological subtypes of meningiomas could be assessed preoperatively using apparent diffusion coefficient (ADC) values. Materials and methods: Conventional magnetic resonance (MR) and diffusion-weighted (DW) imaging of 177 adult patients with pathologically proven meningiomas were retrospectively evaluated. Tumor size and the degree of associated edema were noted. The signal intensity of the lesions on DW imaging was evaluated and graded. Mean ADC values were obtained as the mean of measurements from three regions of interests within the mass. ADC ratios of meningioma/contralateral normal appearing subcortical parietal white matter were also calculated. Results: The histopathological analysis revealed 135 benign, 37 atypical and 5 malignant lesions. With classification according to the subtype, the mean ADC values and ratios of benign meningiomas were as 0.99 ± 0.12 × 10{sup −3} mm{sup 2}/s and 1.22 ± 0.07, respectively. ADC values for atypical and malignant groups were both 0.84 ± 0.1 × 10{sup −3} mm{sup 2}/s. The ADC ratios were 1.05 ± 0.1 and 0.96 ± 0.2 for atypical and malignant subtypes, respectively. There was no statistically significant difference between the mean ADC ratios of the three subtypes (ANOVA test; P ≥ 0.05). Gender, age of the patients and tumor size showed no statistically significant difference between the different histological groups. Conclusion: DW MR imaging was not found to have any additional value in determining histological behaviour nor in differentiating histopathological subtypes of meningiomas.

  1. Diffusion-weighted perinatal postmortem magnetic resonance imaging as a marker of postmortem interval

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom); UCL Institute of Child Health, Imaging and Biophysics, London (United Kingdom); Price, Gemma C. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom); Carmichael, David W. [UCL Institute of Child Health, Imaging and Biophysics, London (United Kingdom); Jones, Rod; Norman, Wendy; Taylor, Andrew M. [Great Ormond Street Hospital for Children NHS Foundation Trust, Cardiorespiratory Division, London (United Kingdom); UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London (United Kingdom); Sebire, Neil J. [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Histopathology, London (United Kingdom); UCL Institute of Child Health, Histopathology, London (United Kingdom)

    2015-05-01

    To evaluate perinatal body organ apparent diffusion coefficient (ADC) values at postmortem magnetic resonance imaging (PMMR) in order to evaluate postmortem changes. Postmortem diffusion-weighted imaging (DWI) of the thorax and abdomen were performed with diffusion gradient values b = 0, 500, and 1000 s/mm{sup 2} on 15 foetal and childhood cases (mean 33.3 ± 7.8 weeks gestation) compared to 44 live infants (mean age 75.5 ± 53.4 days). Mean ADC values were calculated from regions of interest (ROIs) for the lungs, liver, spleen and renal cortex, compared to normative live infantile body ADC values of similar gestational age. Mean ADC values were significantly lower in postmortem cases than in normal controls for liver (0.88 10{sup -3} mm{sup 2}/s ± SD 0.39 vs. 1.13 ± 0.13; p < 0.05) and renal cortex (0.85 ± 0.26 vs. 1.19 ± 0.13; p < 0.05) but not spleen or muscle. Mean lung ADC values were significantly higher than normal controls (1.06 ± 0.18 vs. 0 ± 0; p < 0.001), and there was a significant correlation between postmortem interval and lung ADC (R{sup 2} = 0.55). Lung PMMR ADC values are related to postmortem interval, making them a potential marker of time since death. Further research is needed to understand the organ-specific changes which occur in the postmortem period. (orig.)

  2. Diffusion-weighted MR imaging of salivary glands with gustatory stimulation - Comparison before and after radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yunyan; Gu, Yajia; Peng, Weijun; Mao, Jian; Lei, Yue; Shen, Xigang [Dept. of Radiology, Fudan Univ. Shanghai Cancer Center, Shanghai (China); Dept. of Oncology, Shanghai Medical College, Fudan Univ., Shanghai (China); Ou, Dan; He, Xiayun [Dept. of Radiation Oncology, Fudan Univ. Shanghai Cancer Center, Shanghai (China); Dept. of Oncology, Shanghai Medical College, Fudan Univ., Shanghai (China)

    2013-10-15

    Background: Xerostomia is the most prominent complication in patients with head and neck carcinoma after radiotherapy (RT). Diffusion-weighted magnetic resonance imaging (DWI) with gustatory stimulation may contribute to the evaluation of salivary gland function. Purpose: To investigate the value of DWI for quantifying physiological changes of the parotid gland during gustatory stimulation in patients before and after RT. Material and Methods: Magnetic resonance imaging (MRI) was performed in 28 consecutive patients with nasopharyngeal carcinoma before and after RT and clinical xerostomia was also assessed. A DWI sequence was performed once at rest and continually repeated seven times during stimulation with ascorbic acid. Apparent diffusion coefficient (ADC) maps for parotid glands at different time points and the range of increase with stimulation were calculated. Paired two-tailed Student t tests were used to compare the ADC values before and after stimulation, and before and after RT. Results: Before RT, the ADC showed an initial increase (P<0.001) and then fluctuated during stimulation. After RT, as the clinical xerostomia changed from Grade 0 to Grade 2, the mean ADC at rest increased compared with the pre-RT value (P<0.001). A similar response to stimulation was observed, but the range of increase between the maximum ADC during stimulation and the baseline value at rest was higher post-RT than pre-RT (P=0.022). The minimum ADC during stimulation was higher than the baseline value post-RT (P=0.028), but there was no difference pre-RT (P=0.603). Conclusion: DWI combined with gustatory stimulation seems to display the physiological changes of the parotid gland following RT and may be a potential tool for non-invasively assessing salivary gland function.

  3. Diffusion-weighted imaging of suspicious (BI-RADS 4 breast lesions: stratification based on histopathology

    Directory of Open Access Journals (Sweden)

    João Ricardo Maltez de Almeida

    Full Text Available Abstract Objective: To test the use of diffusion-weighted imaging (DWI in stratifying suspicious breast lesions (BI-RADS 4, correlating them with histopathology. We also investigated the performance of DWI related to the main enhancement patterns (mass and non-mass and tested its reproducibility. Materials and Methods: Seventy-six patients presented 92 lesions during the sampling period. Two independent examiners reviewed magnetic resonance imaging studies, described the lesions, and determined the apparent diffusion coefficient (ADC values. Differences among benign, indeterminate- to high-risk, and malignant findings, in terms of the ADCs, were assessed by analysis of variance. Using receiver operating characteristic (ROC curves, we compared the performance of ADC values in masses and non-mass lesions, and tested the reproducibility of measurements by determining the coefficient of variation and smallest real difference. Results: Among the 92 lesions evaluated, the histopathology showed that 37 were benign, 11 were indeterminate- to high-risk, and 44 were malignant. The mean ADC differed significantly among those histopathological groups, the value obtained for the malignant lesions (1.10 × 10-3 mm2/s being significantly lower than that obtained for the other groups (p < 0.001. ROC curves demonstrated that DWI performed better when applied to masses than when applied to non-mass lesions (area under the curve, 0.88 vs. 0.67. Reproducibility was good (coefficient of variation, 7.03%; and smallest real difference, ± 0.242 × 10-3 mm2/s. Conclusion: DWI can differentiate between malignant and nonmalignant (benign or indeterminate- to high-risk lesions, showing better performance for masses. Nevertheless, stratification based on histopathological criteria that are more refined has yet to be achieved.

  4. Correlation of brain stem diffusion-weighted imaging score with vertebrobasilar artery stenosis in patients with acute brain stem infarction

    OpenAIRE

    Jing-sheng YU; Hui-sheng CHEN

    2015-01-01

    Objective To investigate the correlation of brain stem diffusion-weighted imaging (DWI) lesion score with vertebrobasilar artery stenosis as revealed by magnetic resonance angiography (MRA) in patients with acute brain stem infarction. Methods A total of 253 patients diagnosed as acute brain stem infarction by means of brain magnetic resonance imaging were analyzed retrospectively. Of them 211 patients were enrolled in the present study, and they were qualified with the enrolling standard, an...

  5. Multishot diffusion-weighted SPLICE PROPELLER MRI of the abdomen.

    Science.gov (United States)

    Deng, Jie; Omary, Reed A; Larson, Andrew C

    2008-05-01

    Multishot FSE (fast spin echo)-based diffusion-weighted (DW)-PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI offers the potential to reduce susceptibility artifacts associated with single-shot DW-EPI (echo-planar imaging) approaches. However, DW-PROPELLER in the abdomen is challenging due to the large field-of-view and respiratory motion during DW preparation. Incoherent signal phase due to motion will violate the Carr-Purcell-Meiboom-Gill (CPMG) conditions, leading to destructive interference between spin echo and stimulated echo signals and consequent signal cancellation. The SPLICE (split-echo acquisition of FSE signals) technique can mitigate non-CPMG artifacts in FSE-based sequences. For SPLICE, spin echo and stimulated echo are separated by using imbalanced readout gradients and extended acquisition window. Two signal families each with coherent phase properties are acquired at different intervals within the readout window. Separate reconstruction of these two signal families can avoid destructive phase interference. Phantom studies were performed to validate signal phase properties with different initial magnetization phases. This study evaluated the feasibility of combining SPLICE and PROPELLER for DW imaging of the abdomen. It is demonstrated that DW-SPLICE-PROPELLER can effectively mitigate non-CPMG artifacts and improve DW image quality and apparent diffusion coefficient (ADC) map homogeneity. (c) 2008 Wiley-Liss, Inc.

  6. Intraparenchymal epidermoid cysts in the brain: diagnostic value of MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hu, X.-Y. [Medical Imaging Center, The First Affiliated Hospital of Suzhou, Jiangsu Province (China); Hu, C.-H. [Imaging Center, Soochow University (China)], E-mail: wpdrhxy@hotmail.com; Fang, X.-M.; Cui, L.; Zhang, Q.-H. [Medical Imaging Center, The First Affiliated Hospital of Suzhou, Jiangsu Province (China)

    2008-07-15

    Aim: To evaluate the value of magnetic resonance (MR) diffusion-weighted imaging (DWI) and apparent diffusion coefficients (ADC) maps in the diagnosis of intraparenchymal epidermoid cysts (ECs). Materials and methods: Six cases of histopathologically proven intraparenchymal ECs were studied. All patients were examined with conventional MR (T1WI, T2WI, contrast-enhanced T1WI) and DWI sequences. Along with the mean ADC values (mADC) of the ECs, the cerebrospinal fluid (CSF) and grey matter (GM) were measured. Qualitative and quantitative assessments, as well as MRI findings, were retrospectively analysed using a double blind method by three radiologists in consensus. Results: Four lesions were located in the cerebellum, among them, one was accompanied by an arachnoid cyst; one huge lesion crossed the parenchyma of the frontal and temporal lobes; the other was located in the left temporal lobe. Two lesions had a homogeneous CSF-like intensity on both T1WI and T2WI. The other four were of mixed-intensity on both T1WI and T2WI. All lesions were strikingly hyperintense on DWI, and iso- or slightly hypointense on ADC (relative to the brain). The mADCs of the ECs were significantly higher than that of GM, but significantly lower than that of CSF. Three cases (3/6) were accurately diagnosed using conventional MR sequences without DWI, but in the remaining three cases, correct diagnosis could only be made with help of DWI. Conclusion: DWI sequences can facilitate the diagnosis of intraparenchymal ECs, thus alerting surgeons of the risk of chemical meningitis at surgery. The MR findings of intraparenchymal ECs are basically as the same as those of extracerebral ECs, but the former is likely to have a mixed signal. The hyperintense signal of ECs on DWI is probably caused by the T2 shine-through effect in tumour tissue.

  7. Diffusion-weighted imaging in assessing renal pathology of chronic kidney disease: A preliminary clinical study

    International Nuclear Information System (INIS)

    Li, Qinghai; Li, Jinning; Zhang, Lan; Chen, Ying; Zhang, Minming; Yan, Fuhua

    2014-01-01

    Objective: To investigate the clinical potential of diffusion-weighted imaging (DWI) in assessing renal pathology of chronic kidney disease (CKD). Methods: Seventy-one CKD patients and twelve healthy volunteers were examined using DWI with prospective acquisition correction. Renal biopsy specimens from the CKD patients were scored based on the severity of renal pathology and to confirm pathology type. CKD patients were divided into three groups according to pathology scores: mild, moderate, or severe. The association between renal apparent diffusion coefficient (ADC) values and pathology scores was investigated using Pearson's correlation and single factor analysis of variance. Multiple linear regression analysis was performed to explore associations between renal ADC values and pathology score, glomerular filtration rate, serum creatinine, and age. The Kruskal–Wallis H test was conducted to compare ADC values and pathology type. Results: Renal ADC values correlated negatively with pathology scores (r = −0.633, P < 0.001). The ADC values among the four groups (mild, moderate, severe impairment, and controls) were significantly different (F = 19.512, P < 0.001). However, when patients were stratified by pathology type, no significant differences were found in ADC values among these groups (χ 2 = 9.929, P = 0.270). Further multiple linear regression analysis showed that only the pathology score and ADC values were related (t = −4.586, P = 0.000). Conclusions: DWI has clinical potential in assessing the severity of renal pathology in CKD and shows promise as a non-invasive and effective technique to guide therapy and follow-up

  8. Diffusion-weighted imaging of the kidneys in haemolytic uraemic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Jochen [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Hamburg (Germany); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, Hamburg (Germany); Wenzel, Ulrich [University Medical Center Hamburg-Eppendorf, III. Department of Internal Medicine, Hamburg (Germany); Galler, Stephanie; Schoennagel, Bjoern P.; Bannas, Peter; Yamamura, Jin; Groth, Michael; Adam, Gerhard [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Hamburg (Germany); Busch, Jasmin D.; Tozakidou, Magdalini [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, Hamburg (Germany); Petersen, Kay U. [University Hospital of Tuebingen, Department for Psychiatry and Psychotherapy, Section for Addiction Research and Therapy, Tuebingen (Germany); Joekel, Michaela [Siemens AG Healthcare, Hamburg (Germany); Habermann, Christian R. [Katholisches Marienkrankenhaus Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany)

    2017-11-15

    To evaluate the kidneys of patients with haemolytic uraemic syndrome (HUS) using diffusion-weighted imaging (DWI) and Doppler ultrasound (US) compared with healthy controls. Fifteen patients (mean age 33.3 years; three male; 12 female) with diarrhoea-positive HUS and 15 healthy volunteers were prospectively evaluated with DWI and Doppler US. A total apparent diffusion coefficient (ADC{sub TOT}), and ADCs predominantly reflecting microperfusion (ADC{sub LOW}) and diffusion (ADC{sub HIGH}) were calculated. Doppler US evaluated renal vascularity and flow. When compared with controls, kidneys affected by HUS showed reduced cortical ADC values (ADC{sub TOT} 1.79±0.22 vs. 2.04±0.1x10{sup -3} mm{sup 2}/s, P 0.001), resulting in either low corticomedullary differences (11/15 patients) or an inverted corticomedullary pattern (4/15 patients). Reduction of cortical ADC values was associated with a decrease of cortical vascularity on Doppler US (ADC{sub TOT}, P<0.001; ADC{sub LOW}, P 0.047). Kidneys with complete absence of the cortical vasculature on Doppler US (four patients) also demonstrated limited diffusion (ADC{sub HIGH}, P 0.002). Low glomerular filtration rate, requirement for haemodialysis during hospitalization, and longer duration of haemodialysis were associated with decreased cortical diffusivity (ADC{sub TOT:} P 0.04, 0.007, and <0.001, respectively). DWI shows qualitative and quantitative abnormalities in kidneys affected by HUS, thereby extending the non-invasive assessment of renal parenchymal damage. (orig.)

  9. Usefulness of diffusion-weighted images in the evolving stroke: correlation with clinical findings

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Yoon, Yong Kyu; Kim, Dong Ik; Yoon, Pyeong Ho; Lee, Seung Ik; Lee, Byung In; Suh, Bum Chun

    2000-01-01

    To determine the usefulness of repeat diffusion-weighted imaging (DWI) during the acute ischemic stroke stage for the prediction of evolving stroke and clinical course. Fifteen patients with acute ischemic stroke in MCA territory (less than 24 hours, 5 patients; greater than 24 hours, 10 patients; M:F =3D (:6; age 28-75 (mean, 61) years) were involved in this prospective study. All patients underwent initial DWI, follow-up DWI (within two weeks of the first attack) and T2WI (2-5 months later to assess final infarction territory). The National Institute of Health Stroke Scale (NIHSS) was used for clinical evaluation. 'Evolving stroke' was defined as progression NIHSS after admission. For statistical analysis, Fisher's exact test was used and a p value less than 0.05 was considered significant.In six patients (40%), the diagnosis was evolving stroke. In four of these (67%), follow-up DWI showed that the infarction territory was more extensive. Evolving stroke occurred 24-72 hours after the onset of symptoms. DWI obtained 72 hours after onset showed that one patient had developed new infarction. Patients in whom enlarged infarction territory was seen on follow-up DWI showed progression of NIHSS within three days of onset, while those in whom follow-up DWI demonstrated no change showed an improved NIHSS (p less than 0.05). Those who underwent initial DWI within 24 hours of onset showed larger infarction territory on follow-up DWI than those who underwent initial DWI later than this (p greater than 0.05). Repeat DWI during the acute ischemic stroke stage might be useful for the evaluation of evolving stroke. (author)

  10. Diffusion-weighted imaging in assessing renal pathology of chronic kidney disease: A preliminary clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qinghai; Li, Jinning; Zhang, Lan; Chen, Ying; Zhang, Minming [Department of Radiology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009 (China); Yan, Fuhua, E-mail: zemylife@163.com [Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025 (China)

    2014-05-15

    Objective: To investigate the clinical potential of diffusion-weighted imaging (DWI) in assessing renal pathology of chronic kidney disease (CKD). Methods: Seventy-one CKD patients and twelve healthy volunteers were examined using DWI with prospective acquisition correction. Renal biopsy specimens from the CKD patients were scored based on the severity of renal pathology and to confirm pathology type. CKD patients were divided into three groups according to pathology scores: mild, moderate, or severe. The association between renal apparent diffusion coefficient (ADC) values and pathology scores was investigated using Pearson's correlation and single factor analysis of variance. Multiple linear regression analysis was performed to explore associations between renal ADC values and pathology score, glomerular filtration rate, serum creatinine, and age. The Kruskal–Wallis H test was conducted to compare ADC values and pathology type. Results: Renal ADC values correlated negatively with pathology scores (r = −0.633, P < 0.001). The ADC values among the four groups (mild, moderate, severe impairment, and controls) were significantly different (F = 19.512, P < 0.001). However, when patients were stratified by pathology type, no significant differences were found in ADC values among these groups (χ{sup 2} = 9.929, P = 0.270). Further multiple linear regression analysis showed that only the pathology score and ADC values were related (t = −4.586, P = 0.000). Conclusions: DWI has clinical potential in assessing the severity of renal pathology in CKD and shows promise as a non-invasive and effective technique to guide therapy and follow-up.

  11. Biexponential analysis of diffusion-weighted imaging: comparison of three different calculation methods in transplanted kidneys.

    Science.gov (United States)

    Heusch, Philipp; Wittsack, Hans-Jörg; Pentang, Gael; Buchbender, Christian; Miese, Falk; Schek, Julia; Kröpil, Patric; Antoch, Gerald; Lanzman, Rotem S

    2013-12-01

    Biexponential analysis has been used increasingly to obtain contributions of both diffusion and microperfusion to the signal decay in diffusion-weighted imaging DWI of different parts of the body. To compare biexponential diffusion parameters of transplanted kidneys obtained with three different calculation methods. DWI was acquired in 15 renal allograft recipients (eight men, seven women; mean age, 52.4 ± 14.3 years) using a paracoronal EPI sequence with 16 b-values (b = 0-750 s/mm(2)) and six averages at 1.5T. No respiratory gating was used. Three different calculation methods were used for the calculation of biexponential diffusion parameters: Fp, ADCP, and ADCD were calculated without fixing any parameter a priori (calculation method 1); ADCP was fixed to 12.0 µm(2)/ms, whereas Fp and ADCD were calculated using the biexponential model (calculation method 2); multistep approach with monoexponential fitting of the high b-value portion (b ≥ 250 s/mm(2)) for determination of ADCD and assessment of the low b intercept for determination of Fp (calculation method 3). For quantitative analysis, ROI measurements were performed on the according parameter maps. Mean ADCD values of the renal cortex using calculation method 1 were significantly lower than using calculation methods 2 and 3 (P < 0.001). There was a significant correlation between calculation methods 1 and 2 (r = 0.69 (P < 0.005) and calculation methods 1 and 3 (r = 0.59; P < 0.05) as well as calculation methods 2 and 3 (r = 0.98; P < 0.001). Mean Fp values of the renal cortex were higher with calculation method 1 than with calculation methods 2 and 3 (P < 0.001). For Fp, only the correlation between calculation methods 2 and 3 was significant (r = 0.98; P < 0.001). Biexponential diffusion parameters differ significantly depending on the calculation methods used for their calculation.

  12. Biexponential signal attenuation analysis of diffusion-weighted imaging of breast

    International Nuclear Information System (INIS)

    Tamura, Takayuki; Naito, Kumiko; Usui, Shuji; Akiyama, Mitoshi; Murakami, Shigeru; Arihiro, Koji; Akiyama, Yuji

    2010-01-01

    In vivo, the attenuation of diffusion-weighted imaging (DWI) signal at high b-values is sometimes nonlinear when plotted with semilogarithmic function and is fit well by a biexponential function. Previous reports have indicated that the fast and slow component fractions of the apparent diffusion coefficient (ADC) can be derived by biexponential fitting and that these fractions correspond to the actual diffusion components in the extra- and intracellular space. In this study, we investigated the clinical utility of DWI for the breast by performing DWI using multiple b-factors on healthy volunteers and clinical subjects, analyzing the signal by fitting it with a biexponential equation, and comparing the fitting parameters of breast lesions. We investigated 8 healthy women as normal cases and 80 female patients with a total of 100 breast tumors (42 benign, 58 malignant tumors) as clinical cases. We performed DWI using 12 b-values for the healthy cases and 6 b-values for the clinical cases, up to a maximum b-value of 3500 s/mm 2 . Decay of DWI signal of normal mammary glands, most cysts, and some fibroadenomas showed a monoexponential relationship, and conversely, that of intraductal papilloma (IDP) and malignant tumors was well fitted by a biexponential function. Comparison of parameters derived from biexponential fitting demonstrated no significant difference between benign and malignant lesions. For malignant tumor subtype, the fast component fraction of noninvasive ductal carcinoma was statistically greater than that of invasive ductal carcinoma. Although the parameters from biexponential fitting may reflect the character of tumor cellularity, because pathological diagnosis was performed with an emphasis on cell configuration or shape rather than cellularity, it was difficult to distinguish malignant from benign tumors, including many IDPs, or to distinguish tissue types using DWI signal attenuation alone. (author)

  13. MR diffusion-weighted imaging in differential diagnosis of intracranial cystic lesions

    International Nuclear Information System (INIS)

    Ji Xueman; Lu Guangming; Wang Zhongqiu; Zhang Zongjun; Zhang Zhiqiang; Wang Junpeng

    2007-01-01

    Objective: To evaluate the value of diffusion-weighted imaging (DWI) on differential diagnosis of intracranial cystic lesions. Methods: Seventy-six patients with surgically and pathologically confirmed intracranial cystic lesions undergone conventional MRI, DWI and contrast enhanced MRI examination. The signal characteristics of intracranial cystic lesions on DWI were analysed retrospectively, the apparent diffusion coefficient (ADC) values of cystic areas were measured quantitatively. Results: Nineteen brain abscesses showed hyperintense signal on DWI. Among 34 brain tumors, 3 brain gliomas were hyperintense signal, 1 brain glioma was isointense signal and 1 metastasis was hyperintense signal; the other 29 brain tumors showed hypointense signal on DWI. The ADC values of all lesions were: (0.62 ± 0.15) x 10 -3 mm 2 /s in brain abscesses, (2.39 ± 0.78) x 10 -3 mm 2 /s in brain gliomas, (2.68 ± 0.40) x 10 -3 mm 2 /s in brain hemangioblastomas, (2.79 ± 0.79) x 10 -3 mm 2 /s in brain metastases, respectively. There were significant differences between the ADC values of brain abscess and the cystic or necrotic portions of brain glioma, hemangioblastoma, metastasis (P 0.05). Seven intracranial arachnoid cysts showed hypointense signal and 16 epidermoid cysts strikingly hyperintense signal on DWI. The ADC values of arachnoid cysts and epidermoid cysts were (2.96 ± 0.36) x 10 -3 mm 2 /s and (0.94 ± 0.13) x 10 -3 mm 2 /s respectively. There was significant difference between the ADC values of arachnoid cysts and epidermoid cysts (P<0.01). Conclusion: DWI and ADC values have important contribution to the differentiation of brain abscesses from cystic or necrotic tumors, intracranial cystic lesions showing hypointense signal on DWI can exclude brain abscess. (authors)

  14. Superselective intra-arterial fibrinolysis for acute cerebral ischemic infarct : usefulness of diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Byun, Woo Mok; Lee, Se Jin; Kim, Yong Sun; Han, Gun Soo; Bae, Won Kyong

    1999-01-01

    To evaluate the efficacy of superselective intra-arterial fibrinolysis for acute cerebral stroke and the usefulness of pre-and postfibrinolysis diffusion-weighted MRI (DWI). In 41 patients with acute ischemic stroke whose treatment involved intra-arterial fibrinolysis, the occlusion site, degree of recanalization, and clinical results were compared. In 12 patients, diffusion weighted MRI was performed before fibrinolysis, and eight of these also underwent diffusion-weighted MRI after fibrinolysis. Using diffusion-weighted MRI, neurological outcomes were compared with signal intensity ratio (SIR, or the average signal intensity within the region of interest divided by that in the contralateral, nonischemic, homologous region). Twenty patients showed complete recanalization, nine partial recanalization, and in twelve there was no recanalization. Fourteen patients (34%) improved neurologically. No relationship existed between occlusion sites, degree of recanalization, and clinical outcome. Among 12 patients who underwent DWI before fibrinolysis, complete recanalization was noted in eight. Neurological improvement was seen in four patients with low SIR( 1.7), neurological outcome was poor despite complete recanalization. Although superselective intra-arterial fibrinolysis for acute cerebral stroke is a good therapeutic method for recanalization, the clinical outcome can be disappointing. We therefore suggest that in cases of acute cerebral ischemic infaret, SIR-as seen on DWI-might be useful for predicting the benefits of recanalization. In such cases, further investigation of the use of DWI prior to fibrinolysis is therefore needed

  15. Hypercellularity Components of Glioblastoma Identified by High b-Value Diffusion-Weighted Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pramanik, Priyanka P. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Parmar, Hemant A. [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Mammoser, Aaron G.; Junck, Larry R. [Department of Neurology, University of Michigan, Ann Arbor, Michigan (United States); Kim, Michelle M.; Tsien, Christina I.; Lawrence, Theodore S. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Cao, Yue, E-mail: yuecao@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan (United States)

    2015-07-15

    Purpose: Use of conventional magnetic resonance imaging (MRI) for target definition may expose glioblastomas (GB) to inadequate radiation dose coverage of the nonenhanced hypercellular subvolume. This study aimed to develop a technique to identify the hypercellular components of GB by using high b-value diffusion-weighted imaging (DWI) and to investigate its relationship with the prescribed 95% isodose volume (PDV) and progression-free survival (PFS). Methods and Materials: Twenty-one patients with GB underwent chemoradiation therapy post-resection and biopsy. Radiation therapy (RT) treatment planning was based upon conventional MRI. Pre-RT DWIs were acquired in 3 orthogonal directions with b-values of 0, 1000, and 3000 s/mm{sup 2}. Hypercellularity volume (HCV) was defined on the high b-value (3000 s/mm{sup 2}) DWI by a threshold method. Nonenhanced signified regions not covered by the Gd-enhanced gross tumor volume (GTV-Gd) on T1-weighted images. The PDV was used to evaluate spatial coverage of the HCV by the dose plan. Association between HCV and PFS or other clinical covariates were assessed using univariate proportional hazards regression models. Results: HCVs and nonenhanced HCVs varied from 0.58 to 67 cm{sup 3} (median: 9.8 cm{sup 3}) and 0.15 to 60 cm{sup 3} (median: 2.5 cm{sup 3}), respectively. Fourteen patients had incomplete dose coverage of the HCV, 6 of whom had >1 cm{sup 3} HCV missed by the 95% PDV (range: 1.01-25.4 cm{sup 3}). Of the 15 patients who progressed, 5 progressed earlier, within 6 months post-RT, and 10 patients afterward. Pre-RT HCVs within recurrent GTVs-Gd were 78% (range: 65%-89%) for the 5 earliest progressions but lower, 53% (range: 0%-85%), for the later progressions. HCV and nonenhanced HCV were significant negative prognostic indicators for PFS (P<.002 and P<.01, respectively). The hypercellularity subvolume not covered by the 95% PDV was a significant negative predictor for PFS (P<.05). Conclusions: High b-value DWI

  16. Evaluation of gastric cancer detectability on respiratory triggered-diffusion weighted image

    International Nuclear Information System (INIS)

    Ichiba, Noriatsu; Fukuda, Kunihiko; Takahashi, Naoto; Nikaido, Takashi; Urashima, Mitsuyoshi; Kitagawa, Hisashi

    2007-01-01

    The objective of this study was to assess the ability of respiratory triggered diffusion-weighted image (RT-DWI) to detect gastric cancer and to determine whether there is any correlation between the detectability of RT-DWI and the location of cancerous tissues. Sixty-nine gastric cancer patients (71 lesions) underwent pre-operative magnetic resonance (MR) imaging and total or partial gastrectomy. Scans of the stomach were acquired using a 1.5T MR scanner. Our protocol consisted of T1WI, T2WI and DWI (b value=800 sec/mm 2 ). The location of gastric cancer was classified into three areas -U, M and L. The condition of the gastric contents and the relation between the location of intraluminal gas and gastric lesions were also evaluated. There were 42 early gastric cancers and 29 advanced cancers in a total of 71 lesions. In early gastric cancers, 15 lesions were detected out of 42 lesions (35.7%) and, in advanced gastric cancers, 27 lesions were detected out of 29 lesions (93.0%). Pathological volumes of the detected lesions ranged between 12 mm x 8 mm x 1 mm and 190 mm x 135 mm x 10 mm (median 57 mm x 35 mm x 5 mm), and those of the undetected lesions ranged between 5 mm x 2 mm x 1 mm and 67 mm x 47 mm x 1.5 mm (median 23 mm x 17 mm x 1 mm). Detectability of the lesions appeared to be higher in the following three conditions when the gastric lumen was filled with mainly fluid rather than gas when there was no intraluminal gas adjacent to the lesion when the imaging quality of RT-DWI was good. RT-DWI was found to have a high detection (93.0%) rate of advanced gastric cancers. To improve the detectability of early gastric cancers, we should endeavor to minimize the susceptibility artifact from intraluminal gas in the stomach and select higher resolution protocols. (author)

  17. Value of diffusion-weighted imaging for diagnosting vertebral metastases due to prostata cancer in comparison to other primary tumors

    International Nuclear Information System (INIS)

    Hacklaender, T.; Scharwaechter, C.; Mertens, H.; Golz, R.

    2006-01-01

    Purpose: Several publications have reported that the apparent diffusion coefficient is generally lower in metastatically affected vertebrae. Therefore, metastases are represented in diffusion-weighted images by increased signal intensity in comparison to unaffected vertebrae. However, there were indications that metastases due to prostate cancer may differ from this. Therefore, the contrast behavior of vertebral metastases due to prostate cancer or tumors with another histology are to be systematically studied using diffusion-weighted images. The present study is intended to examine whether the two groups differed and whether possible differences depended on the degree of sclerosis. Materials and Method: In a retrospective study the vertebral metastases of patients with prostate cancer (n=18) were compared to those of patients with tumors of another histology (n=20). A steady-state free precession sequence was used for the diffusion-weighted imaging. Additionally, a T1 weighted sequence before and after administration of contrast agent as well as a fat suppressed T2 weighted sequence were performed. The contrast behavior of the metastases was evaluated for all four sequences and was compared to that of the unaffected parts of the vertebra. Results: In 18 patients of the tumor group, the vertebral metastases showed positive contrast in the diffusion-weighted images, and 2 had minimally negative contrast up to -0.04. In the prostate cancer group, the contrast was positive in 9 patients and negative in 9.6 of the metastases with negative contrast had an osteoblastic metastasization, 1 had an osteolysis, and 1 had a normal finding in the conventional X-ray image. Between the tumor group and the prostate cancer group, the medians of the contrasts were not significantly different (p=0.054). (orig.)

  18. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Gonen, Korcan Aysun, E-mail: aysunbalc@yahoo.com [Department of Radiology, State Hospital, Eski Cami district, Hastane street, N:1, 59300, Tekirdag (Turkey); Simsek, Mehmet Masum, E-mail: radyoloji@haydapasanumune.gov.tr [Department of Radiology, Haydarpasa Numune Training and Research Hospital, Tibbiye street, Uskudar 34200, Istanbul (Turkey)

    2010-11-15

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC{sub IC}), ischemic penumbra (ADC{sub P}) and the nonischemic parenchymal tissue (ADC{sub N}). P values < 0.05 were accepted to be statistically significant. Results: During the between 6 and 12 h mean infarction volume calculated by DWI was 23.3 cm{sup 3} for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm{sup 3} (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm{sup 3} (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC{sub IC} and ADC{sub N} values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC{sub P} values between the groups was found to be highly significant (p < 0.001). When the differences between the ADC{sub P} and ADC{sub IC} and ADC{sub N} and ADC{sub P} were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from

  19. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    International Nuclear Information System (INIS)

    Gonen, Korcan Aysun; Simsek, Mehmet Masum

    2010-01-01

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC IC ), ischemic penumbra (ADC P ) and the nonischemic parenchymal tissue (ADC N ). P values 3 for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm 3 (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm 3 (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC IC and ADC N values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC P values between the groups was found to be highly significant (p P and ADC IC and ADC N and ADC P were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from the core and the penumbra of the infarction area will be beneficial in the estimation of the infarction prognosis and in the planning of a treatment protocol.

  20. Diffusion-weighted MR imaging and ADC mapping in differentiating benign from malignant thyroid nodules

    International Nuclear Information System (INIS)

    Khizer, A.T.; Slehria, A.U.R.

    2015-01-01

    To determine the diagnostic accuracy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping in differentiating benign from malignant thyroid nodules by taking histopathology as the gold standard. Study Design:Across-sectional analytical study. Place and Duration of Study: Department of Radiology at Combined Military Hospital (CMH), Lahore, from August 2012 to July 2013. Methodology: Thirty-five patients, who were referred to radiology department of CMH, Lahore, for ultrasound or Fine Needle Aspiration Cytology (FNAC) of thyroid gland, fulfilling the inclusion and exclusion criteria, were included in the study. They were evaluated on 1.5 Tesla MRI machine with T1- and T2-weighted imaging as well as fat-suppressed technique. DWI was done using b-values of 0 and 1000 s/mm2 and ADC values were calculated for the thyroid nodules. All of these patients were subjected to ultrasound guided core biopsy and histopathology results were correlated with ADC values. Results: The benign nodules showed facilitated diffusion while malignant nodules showed restricted diffusion. T-test was used to assess the difference in mean ADC values between benign and malignant nodules. The mean ADC value of the malignant thyroid nodules (0.94 ± 0.16 x 10/sup -3/mm2/s) was significantly lower than that of the benign thyroid nodules (1.93 ±0.13 x 10/sup -3/mm2/s) (p-value < 0.05). ADC value of 1.6 x 10/sup -3/mm2/s was used as a cut-off, for differentiating benign from malignant thyroid nodules. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of DWI and ADC values in differentiating benign from malignant thyroid nodules were 93%, 95%, 93%, 95% and 92.3%, respectively. Conclusion: DWI is a non-invasive diagnostic tool for characterization and differentiation between benign and malignant thyroid nodules. It not only decreases the burden of unnecessary surgeries when pre-operative FNAC and biopsy are inconclusive, but is also helpful in reaching a

  1. Diffusion-weighted imaging and proton MR spectroscopy in the characterization of acute disseminated encephalomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramanya, K.S.; Kovoor, J.M.E.; Jayakumar, P.N.; Ravishankar, S.; Kamble, R.B. [National Institute of Mental Health and Neurosciences, Department of Neuroimaging and Interventional Radiology, Bangalore, Karnataka (India); Panicker, J.; Nagaraja, D. [National Institute of Mental Health and Neurosciences, Department of Neurology, Bangalore (India)

    2007-02-15

    Acute disseminated encephalomyelitis (ADEM) is usually a monophasic illness characterized by multiple lesions involving gray and white matter. Quantitative MR techniques were used to characterize and stage these lesions. Eight patients (seven males and one female; mean age 19 years, range 5 to 36 years) were studied using conventional MRI (T2- and T1-weighted and FLAIR sequences), diffusion-weighted imaging (DWI) and proton magnetic resonance spectroscopy (MRS). Apparent diffusion coefficient (ADC) values and MRS ratios were calculated for the lesion and for normal-appearing white matter (NAWM). Three patients were imaged in the acute stage (within 7 days of the onset of neurological symptoms) and five in the subacute stage (after 7 days from the onset of symptoms). ADC values in NAWM were in the range 0.7-1.24 x 10{sup -3} mm/s{sup 2} (mean 0.937 {+-} 0.17 mm/s{sup 2}). ADC values of ADEM lesions in the acute stage were in the range 0.37-0.68 x 10{sup -3} mm/s{sup 2} (mean 0.56 {+-} 0.16 mm/s{sup 2}) and 1.01-1.31 x 10{sup -3} mm/s{sup 2} (mean 1.24 {+-} 0.13 mm/s{sup 2}) in the subacute stage. MRS ratios were obtained for all patients. NAA/Cho ratios were in the range 1.1-3.5 (mean 1.93 {+-} 0.86) in the NAWM. NAA/Cho ratios within ADEM lesions in the acute stage were in the range 0.63-1.48 (mean 1.18 {+-} 0.48) and 0.29-0.84 (mean 0.49 {+-} 0.22) in the subacute stage. The ADC values, NAA/Cho and Cho/Cr ratios were significantly different between lesions in the acute and subacute stages (P < 0.001, P < 0.027, P < 0.047, respectively). ADC values were significantly different between lesions in the acute (P < 0.009) and subacute stages (P < 0.005) with NAWM. In addition, NAA/Cho and Cho/Cr ratios were significantly different between lesions in the subacute stage and NAWM (P < 0.006, P < 0.007, respectively). ADEM lesions were characterized in the acute stage by restricted diffusion and in the subacute stage by free diffusion and a decrease in NAA/Cho ratios

  2. New asymptomatic ischemic lesions on diffusion-weighted imaging after cerebral angiography

    International Nuclear Information System (INIS)

    Shibazaki, Kensaku

    2006-01-01

    Conventional cerebral angiography (CAG) is relatively low risk for neurological complications. However, diffusion-weighted imaging (DWI) after CAG occasionally reveal an asymptomatic ischemic lesion on the brain. The aim of this study was to investigate the frequency of new asymptomatic or symptomatic DWI lesions after CAG and to clarify the factors associated with them. Fifty-six patients with acute ischemic stroke and transient ischemic attack were prospectively enrolled. Magnetic resonance imaging (MRI) studies including DWI were studied twice, within 48 hours before and after CAG. The following factors were assessed; age, gender, history of stroke, history of ischemic heart disease, vascular risk factors, National Institutes of Health Stroke Scale (NIHSS) score on admission, stroke subtype, treatment before stroke or transient ischemic attack (TIA) (antiplatelets or warfarin), approach for catheters (transbrachial or femoral artery), amount of contrast medium used, length of the angiographic procedure, and fluoroscophy time. We divided the patients into two groups according to the presence of new DWI lesions after CAG; Positive group had new DWI lesions, whereas the Negative group had none. After CAG, no patients had new neurological deficits. New asymptomatic DWI lesions were observed in 24 patients (42.9%). The significant differences observed between two groups were as follows; age (69.8±11.3 for the Positive group versus 61.9±11.3 for the Negative group, p=0.043), female (54% versus 28%, p=0.048), non-small vessel occlusion (100% versus 66%, p=0.009), catheter approach for transfemoral artery (63% versus 13%, p<0.001), mean length of the angiographic procedure (63.1±21.6 min versus 43.7±14.2 min, p<0.001), mean fluoroscopy time (26.5±13.0 min versus 14.9±5.9 mm, p<0.001). Sensitivity and specificity analysis to discriminate the positive and negative groups revealed 17 minutes to be the critical threshold point (sensitivity 66.6% and specificity 68

  3. Diffusion-weighted magnetic resonance imaging - a new instrument in the diagnosis of Creutzfeldt-Jacob's disease

    International Nuclear Information System (INIS)

    Romi, Fredrik; Smivoll, Alf Inge; Moerk, Sverre; Tysnes, Ole-Bjoern

    2000-01-01

    Creutzfeldt-Jacob's disease (CID) is characterised by rapidly progressive dementia, ataxia, myoclonus and several other neurological deficits. It generally affects older adults and occurs in sporadic, genetic and iatrogenic forms. Death occurs usually within one year after onset of the disease. The diagnosis is based on clinical criteria, neuro physiological and radiological findings and confirmed by post mortal histopathology. During the last two years several cases of CID have been reported with diffusion-weighted magnetic resonance imaging (MR) abnormalities represented by increased signal intensity indicating reduced diffusion in basal ganglia and/or cortex cerebric. These abnormalities seem to be characteristic of CID. We report a case of CID in a 54 year old woman who developed vertigo, nystagmus, ataxia, myoclonus and dementia over a period of eight months. Diffusion-weighted magnetic resonance imaging showed increased signal intensity in corpus striatum and gyrus conguli. The diagnosis was post mortally confirmed with histopathology. (Author) 7 figs., 15 refs

  4. Use of intravoxel incoherent motion diffusion-weighted imaging in identifying the vascular and avascular zones of human meniscus.

    Science.gov (United States)

    Guo, Tan; Chen, Juan; Wu, Bing; Zheng, Dandan; Jiao, Sheng; Song, Yan; Chen, Min

    2017-04-01

    To investigate the hypothesis that the intravoxel incoherent motion (IVIM) diffusion-weighted imaging may depict microcirculation of meniscus and the perfusion changes in meniscal disorder. Fifty patients received diffusion-weighted MRI with multiple b-values ranging from 0 to 400 s/mm 2 . The four horns of the menisci were divided into normal, degenerated, and torn groups. IVIM parameters including perfusion fraction (f), pseudo-diffusion coefficient (D*), true diffusion coefficient (D), and the product of f and D* (f D*) of normal meniscal red zone and white zone were derived and compared for microcirculation changes of normal, degenerated, and torn posterior horn of the medial meniscus (PMM). The parameters between red and white zones among the groups were compared. Significant differences were considered when P meniscus and the perfusion changes in meniscal disorder. 3 J. Magn. Reson. Imaging 2017;45:1090-1096. © 2016 International Society for Magnetic Resonance in Medicine.

  5. Optimal Parameters to Determine the Apparent Diffusion Coefficient in Diffusion Weighted Imaging via Simulation

    Science.gov (United States)

    Perera, Dimuthu

    Diffusion weighted (DW) Imaging is a non-invasive MR technique that provides information about the tissue microstructure using the diffusion of water molecules. The diffusion is generally characterized by the apparent diffusion coefficient (ADC) parametric map. The purpose of this study is to investigate in silico how the calculation of ADC is affected by image SNR, b-values, and the true tissue ADC. Also, to provide optimal parameter combination depending on the percentage accuracy and precision for prostate peripheral region cancer application. Moreover, to suggest parameter choices for any type of tissue, while providing the expected accuracy and precision. In this research DW images were generated assuming a mono-exponential signal model at two different b-values and for known true ADC values. Rician noise of different levels was added to the DWI images to adjust the image SNR. Using the two DWI images, ADC was calculated using a mono-exponential model for each set of b-values, SNR, and true ADC. 40,000 ADC data were collected for each parameter setting to determine the mean and the standard-deviation of the calculated ADC, as well as the percentage accuracy and precision with respect to the true ADC. The accuracy was calculated using the difference between known and calculated ADC. The precision was calculated using the standard-deviation of calculated ADC. The optimal parameters for a specific study was determined when both the percentage accuracy and precision were minimized. In our study, we simulated two true ADCs (ADC 0.00102 for tumor and 0.00180 mm2/s for normal prostate peripheral region tissue). Image SNR was varied from 2 to 100 and b-values were varied from 0 to 2000s/mm2. The results show that the percentage accuracy and percentage precision were minimized with image SNR. To increase SNR, 10 signal-averagings (NEX) were used considering the limitation in total scan time. The optimal NEX combination for tumor and normal tissue for prostate

  6. Diffusion-weighted imaging in diagnosing neurological disorders in children: a pediatric neurologist's perspective

    Energy Technology Data Exchange (ETDEWEB)

    Benedict, Susan L. [The University of Utah, Division of Pediatric Neurology, P.O. Box 581289, Salt Lake City, UT (United States)

    2007-08-15

    Diffusion-weighted imaging (DWI) has provided a way to measure early changes in cellular function in the central nervous system. It has permitted rapid, less invasive diagnosis and treatment of neurological disorders that were once thought to be untreatable. DWI has also created new avenues of research and alternative ways to measure study outcomes. Seven clinical cases illustrate how DWI enhances the ability of the pediatric neurologist to rapidly diagnose acute neurological disorders in infants and children. (orig.)

  7. Functional evaluation of hydronephrosis by diffusion-weighted MR imaging: Relationship between apparent diffusion coefficient and split glomerular filtration rate

    International Nuclear Information System (INIS)

    Toyoshima, S.; Noguchi, K.; Seto, H.; Shimizu, M.; Watanabe, N.

    2000-01-01

    To determine the relationship between apparent diffusion coefficient (ADC) values measured by diffusion-weighted MR imaging and split renal function determined by renal scintigraphy in patients with hydronephrosis. Material and Methods: Diffusion-weighted imaging on a 1.5 T MR unit and renal scintigraphy were performed in 36 patients with hydronephrosis (45 hydronephrotic kidneys, 21 non-hydronephrotic kidneys). ADC values of the individual kidneys were measured by diffusion-weighted MR imaging. Split renal function (glomerular filtration rate (GFR)) was determined by renal scintigraphy using 99m Tc-DTPA. The relationship between ADC values and split GFR was examined in 66 kidneys. The hydronephrotic kidneys were further classified into three groups (severe renal dysfunction, GFR 25 ml/min, n=28), and mean values for ADCs were calculated. Results: In hydronephrotic kidneys, there was a moderate positive correlation between ADC values and split GFR (R2=0.56). On the other hand, in non-hydronephrotic kidneys, poor correlation between ADC values and split GFR was observed (R2=0.08). The mean values for ADCs of the dysfunctioning hydronephrotic kidneys (severe renal dysfunction, 1.32x10 -3 ±0.18x10 -3 mm 2 /s; moderate renal dysfunction, 1.38x10 -3 ±0.10x10 -3 mm2/s) were significantly lower than that of the normal functioning hydronephrotic kidneys (1.63x10 -3 ±0.12±10 -3 mm 2 /s). Conclusion: These results indicated that measurement of ADC values by diffusion-weighted MR imaging has a potential value in the evaluation of the functional status of hydronephrotic kidneys

  8. Imaging and assessment of diffusion coefficients by magnetic resonance

    International Nuclear Information System (INIS)

    Tintera, J.; Dezortova, M.; Hajek, M.; Fitzek, C.

    1999-01-01

    The problem of assessment of molecular diffusion by magnetic resonance is highlighted and some typical applications of diffusion imaging in the diagnosis, e.g., of cerebral ischemia, changes in patients with phenylketonuria or multiple sclerosis are discussed. The images were obtained by using diffusion weighted spin echo Echo-Planar Imaging sequence with subsequent correction of the geometrical distortion of the images and calculation of the Apparent Diffusion Coefficient map

  9. Preoperative CT versus diffusion weighted magnetic resonance imaging of the liver in patients with rectal cancer

    DEFF Research Database (Denmark)

    Achiam, Michael P; Løgager, Vibeke B; Skjoldbye, Bjørn

    2016-01-01

    . The aim of this study was to evaluate the feasibility of diffusion weighted MRI of the liver as part of a combined MR evaluation of patients with rectal cancers and compare it with the standard preoperative evaluation of the liver with CT. Methods. Consecutive patients diagnosed with rectal cancers were...... asked to participate in the study. Preoperative CT and diffusion weighted MR (DWMR) were compared to contrast enhanced laparoscopic ultrasound (CELUS). Results. A total of 35 patients were included, 15 patients in Group-1 having the standard CT evaluation of the liver and 20 patients in Group-2 having....... Furthermore, one patient had non-resectable metastases after DWMR despite being diagnosed with resectable metastases after CT. Another patient was diagnosed with multiple liver metastases during CELUS, despite a negative CT-scan. Discussion. DWMR is feasible for preoperative evaluation of liver metastases...

  10. Diffusion-weighted imaging in the evaluation of hormonal cyclic changes in abdominal wall endometriomas

    International Nuclear Information System (INIS)

    Genç, B.; Solak, A.; Şahin, N.; Genç, M.; Oğul, H.; Sivrikoz, O. Nermin; Kantarcı, M.

    2014-01-01

    Aim: To investigate the utility of diffusion-weighted (DW) magnetic resonance imaging (MRI) in the diagnosis of abdominal wall endometrioma (AWE) and to compare the ADC (apparent diffusion coefficient) values of AWE with those of the uterine endometrium during two different phases of the menstrual cycle. Materials and methods: A total of 22 women aged between 27 and 42 years (mean 32.8 years) and who had regular menstrual cycles were included in the study. These patients had a total of 25 AWE lesions. The mean and standard deviation of the ADC values of the normal endometrium/AWE were calculated for the menstrual and luteal phases. All examinations were performed using a 1.5 T magnet (b-values of 50, 400, and 800 mm/s 2 ). The results were analysed using the Shapiro–Wilk test, the Pearson correlation test, the analysis of variance (ANOVA) test, and the paired sample t-test. Results: The ADC values of the endometrium were different in the two phases of the menstrual cycle (menstrual phase: 0.924 ± 0.171; luteal phase: 1.171 ± 0.135). Similarly, the ADC values of the AWE were different in these phases (menstrual phase: 0.937 ± 0.256, luteal phase: 1.256 ± 0.215). In both AWE and the uterine endometrium, the ADC measurements were significantly lower in the menstrual phase than during the luteal phase. This difference was statistically significant (p < 0.05). There was no significant difference in the ADC values between the endometrial layer and AWE during the same phase (p = 0.216 for menstrual phase, p = 0.104 for luteal phase, paired sample t-test). Conclusion: The present study demonstrated that in all patients, the DWI features of AWEs were significantly similar to those of the uterine endometrial tissue. Additionally, the ADC measurements of the patients showed similar cyclical changes. These results suggest that the ADC values of a lesion close to the uterine endometrium may be used to differentiate AWE from the other disease entities of the abdominal wall

  11. The predictive value of MR diffusion weighted imaging on the delayed encephalopathy after carbon monoxide poisoning

    International Nuclear Information System (INIS)

    Xiao Xinlan; Fu Lihui; Xi Weimin; Yin Jianhua; Gong Liangeng; Yuan Aimei; Yang Xinyue; Liu Zhiyong

    2007-01-01

    Objective: To investigate the value of diffusion weighted imaging (DWI)in predicting delayed encephalopathy of the rabbits brain after carbon monoxide (CO)poisoning. Methods: Sixty healthy rabbits were put into self-made poisoning cabinet and were poisoned by inhalation of CO. Aeration of CO was stopped when the rabbits became comatous, and the cabinet was kept airpoof for 6 h. The rabbits underwent MRI before poisoning , at 1 h, 3 d, 5 d, 7 d, 15 d, 30 d ,45 d, and 60 d after poisoning respectively. Axial and sagittal T 2 WI, axial T 1 WI and DWI were performed. In the rabbits that did not show symptoms of delayed encephalopathy, the observation was discontinued on the 60th day. In the rabbit that showed the symptoms, the observation was discontinued on the 30th-45th day. The changing pattern of cortical ADC values before and after CO poisoning was observed and its relationship with delayed encephalopathy was investigated. Results: In the group without delayed encephalopathy (15 rabbits), the ADC value at 1 h after poisoning [(7.58±0.36) x 10 -4 mm 2 /s] decreased significantly compared with the pre- poisoning value [(8.02±0.35) x 10 -4 mm 2 /s] (q=0.4441, P -4 mm 2 /s], and maintained at the same level as pre- poisoning at 60 d after poisoning (P >0.05). In the group with delayed encephalopathy (15 rabbits), the ADC value at 1 h after poisoning [(7.40±0.32) x 10 -4 mm 2 /s] decreased significantly compared with the pre- poisoning value [(8.08± 0.32) x 10 -4 mm 2 /s] (q=0.6728, P -4 mm 2 /s], secondly significantly decreased at 15 d [(7.29±0.93) x 10 -4 mm 2 /s] without further recovery. The ADC value decrease at 15d alter poisoning [(7.29±0.93) x 10 -4 mm 2 /s] was significant compared with the prepoisoning ADC value (q=0.7850, P<0.01). Conclusions: There is a correlation between the decrease of the ADC value and the degree of tissue damage. The decrease of the ADC value in acute stage can predict the delayed encephalopathy. The second significant decrease

  12. Diffusion weighted magnetic resonance imaging of kidneys in children with vesicoureteral reflux

    Energy Technology Data Exchange (ETDEWEB)

    Koçyiğit, Ali, E-mail: alkoc@yahoo.com [Pamukkale University Faculty of Medicine, Department of Radiology, Denizli (Turkey); Bayram, Recep [Pamukkale University Faculty of Medicine, Department of Radiology, Denizli (Turkey); Yüksel, Selçuk [Pamukkale University Faculty of Medicine, Department of Pediatric Nephrology, Denizli (Turkey); Yılmaz, İsmail; Karabulut, Nevzat [Pamukkale University Faculty of Medicine, Department of Radiology, Denizli (Turkey)

    2014-01-15

    Purpose: The apparent diffusion coefficient (ADC) which obtain from diffusion-weighted magnetic resonance imaging (DWI), is a quantitative parameter representing the renal function and parenchymal damage in some renal disorders. The primary aim of this study was to investigate whether renal tissue alterations associated with vesicoureteral reflux (VUR) can be displayed by DWI. The secondary aim was to assess how ADC values change with age in kidneys with and without VUR. Materials and methods: This prospective study included 46 patients (8 boys, 38 girls; mean age 7.3 ± 4.2; range 1–15 years) with VUR and 54 control subjects (21 boys, 33 girls; mean age 7.7 ± 5.2; range 1–17 years). All subjects underwent DWI of the kidneys using b value of 600 s/mm{sup 2} in addition to MR urography. The ADC values of 71 kidneys with VUR were compared with those of 81 kidneys without VUR. Results: The mean ADC values were (1.93 ± 0.36) × 10{sup −3} mm{sup 2}/s, (1.97 ± 0.24) × 10{sup −3} mm{sup 2}/s, (1.83 ± 0.37) × 10{sup −3} mm{sup 2}/s, (1.98 ± 0.20) × 10{sup −3} mm{sup 2}/s and (2.08 ± 0.42) × 10{sup −3} mm{sup 2}/s in normal kidneys, and in those with grade 1, grade 2, grade 3 and grade 4 VUR, respectively. There was no significant difference in ADC values between kidneys with and without VUR. There was a significant positive correlation between the age and ADC values both in kidneys with and without VUR (r = 0.79, p < 0.001 and r = 0.82; p < 0.001, respectively). Conclusion: DWI does not reveal probable parenchymal alterations in reflux nephropathy. ADC values increase with age during childhood not only in normal kidneys but also in kidneys with VUR.

  13. The value of diffusion-weighted imaging in combination with T2-weighted imaging for rectal cancer detection

    International Nuclear Information System (INIS)

    Rao Shengxiang; Zeng Mengsu; Chen Caizhong; Li Renchen; Zhang Shujie; Xu Jianming; Hou Yingyong

    2008-01-01

    Objective: To evaluate the clinical value of diffusion-weighted imaging (DWI) in combination with T 2 -weighted imaging (T 2 WI) for the detection of rectal cancer as compared with T 2 WI alone. Materials and methods: Forty-five patients with rectal cancer and 20 without rectal cancer underwent DWI with parallel imaging and T 2 WI on a 1.5 T scanner. Images were independently reviewed by two readers blinded to the results to determine the detectability of rectal cancer. The detectability of T 2 W imaging without and with DW imaging was assessed by means of receiver operating characteristic analysis. The interobserver agreement between the two readers was calculated with kappa statistics. Results: The ROC analysis showed that each of two readers achieved more accurate results with T 2 W imaging combined with DW imaging than with T 2 W imaging alone significantly. The A z values for the two readers for each T 2 WI and T 2 WI combined with DWI were 0.918 versus 0.991 (p = 0.0494), 0.934 versus 0.997 (p = 0.0475), respectively. The values of kappa were 0.934 for T 2 WI and 0.948 for T 2 WI combined with DWI between the two readers. Conclusion: The addition of DW imaging to conventional T 2 W imaging provides better detection of rectal cancer

  14. Comparison of Intravoxel Incoherent Motion Diffusion-Weighted MR Imaging and Arterial Spin Labeling MR Imaging in Gliomas

    Directory of Open Access Journals (Sweden)

    Yuankai Lin

    2015-01-01

    Full Text Available Gliomas grading is important for treatment plan; we aimed to investigate the application of intravoxel incoherent motion (IVIM diffusion-weighted imaging (DWI in gliomas grading, by comparing with the three-dimensional pseudocontinuous arterial spin labeling (3D pCASL. 24 patients (13 high grade gliomas and 11 low grade gliomas underwent IVIM DWI and 3D pCASL imaging before operation; maps of fast diffusion coefficient (D∗, slow diffusion coefficient (D, fractional perfusion-related volume (f, and apparent diffusion coefficient (ADC as well as cerebral blood flow (CBF were calculated and then coregistered to generate the corresponding parameter values. We found CBF and D∗ were higher in the high grade gliomas, whereas ADC, D, and f were lower (all P0.05. IVIM DWI showed more efficiency than 3D pCASL but less validity than conventional DWI in differentiating the high from low grade gliomas.

  15. Diffusion-Weighted Imaging with Color-Coded Images: Towards a Reduction in Reading Time While Keeping a Similar Accuracy

    Directory of Open Access Journals (Sweden)

    Felipe Campos Kitamura

    2016-01-01

    Full Text Available The aim of this study was to develop a diagnostic tool capable of providing diffusion and apparent diffusion coefficient (ADC map information in a single color-coded image and to assess the performance of color-coded images compared with their corresponding diffusion and ADC map. The institutional review board approved this retrospective study, which sequentially enrolled 36 head MRI scans. Diffusion-weighted images (DWI and ADC maps were compared to their corresponding color-coded images. Four raters had their interobserver agreement measured for both conventional (DWI and color-coded images. Differences between conventional and color-coded images were also estimated for each of the 4 raters. Cohen’s kappa and percent agreement were used. Also, paired-samples t-test was used to compare reading time for rater 1. Conventional and color-coded images had substantial or almost perfect agreement for all raters. Mean reading time of rater 1 was 47.4 seconds for DWI and 27.9 seconds for color-coded images (P=.00007. These findings are important because they support the role of color-coded images as being equivalent to that of the conventional DWI in terms of diagnostic capability. Reduction in reading time (which makes the reading easier is also demonstrated for one rater in this study.

  16. Diffusion-Weighted Imaging with Color-Coded Images: Towards a Reduction in Reading Time While Keeping a Similar Accuracy.

    Science.gov (United States)

    Campos Kitamura, Felipe; de Medeiros Alves, Srhael; Antônio Tobaru Tibana, Luis; Abdala, Nitamar

    2016-01-01

    The aim of this study was to develop a diagnostic tool capable of providing diffusion and apparent diffusion coefficient (ADC) map information in a single color-coded image and to assess the performance of color-coded images compared with their corresponding diffusion and ADC map. The institutional review board approved this retrospective study, which sequentially enrolled 36 head MRI scans. Diffusion-weighted images (DWI) and ADC maps were compared to their corresponding color-coded images. Four raters had their interobserver agreement measured for both conventional (DWI) and color-coded images. Differences between conventional and color-coded images were also estimated for each of the 4 raters. Cohen's kappa and percent agreement were used. Also, paired-samples t-test was used to compare reading time for rater 1. Conventional and color-coded images had substantial or almost perfect agreement for all raters. Mean reading time of rater 1 was 47.4 seconds for DWI and 27.9 seconds for color-coded images (P = .00007). These findings are important because they support the role of color-coded images as being equivalent to that of the conventional DWI in terms of diagnostic capability. Reduction in reading time (which makes the reading easier) is also demonstrated for one rater in this study.

  17. Impact of fibroglandular tissue and background parenchymal enhancement on diffusion weighted imaging of breast lesions

    International Nuclear Information System (INIS)

    Iacconi, Chiara; Thakur, Sunitha B.; Dershaw, David D.; Brooks, Jennifer; Fry, Charles W.; Morris, Elizabeth A.

    2014-01-01

    Highlights: • Aim of the paper is to evaluate if the amount of fibroglandular breast tissue (FGT) and the background enhancement(BPE) influence the detection of lesions and their quantitative analysis in diffusion weighted imaging(DWI) • The structure of the breast, including both FGT and BPE, as well as the menopausal status of the patient are not a relevant factor for lesion identification in DWI. • Quantitative analysis of normal breast is not uniform and is influenced by the amount of fibroglandular tissue,while there is no influence of background parenchymal enhancement. - Abstract: Purpose: To evaluate the influence of the amount of fibroglandular breast tissue (FGT) and background-parenchymal enhancement (BPE) on lesion detection, quantitative analysis of normal breast tissue and of breast lesions on DWI. Materials and methods: IRB approved this retrospective study on focal findings at contrast-enhanced (CE) breast MR and DWI performed during July–December 2011. Patients with cysts, previous irradiation, silicone implants and current chemotherapy were excluded. DWI with fat suppression was acquired before dynamic acquisition (b factors: 0.1000 s/mm 2 ) using 1.5 and 3 T scanners. Using correlation with dynamic and T2 images, ROIs were drawn free-hand within the borders of any visible lesion and in contralateral normal breast. Fisher's exact test to evaluate visibility and Wilcoxon-rank-sum test for comparison of ADC values were used. The amount of FGT and BPE was visually assessed by concurrent MRI. Analysis was stratified by menopausal status. Results: 25/127 (20%) lesions were excluded for technical reasons. 65/102 (64%) lesions were visible on DWI (median diameter: 1.85 cm). Mass lesions (M) were more visible (43/60 = 72%) than non-mass enhancement (NME) (22/42 = 52%) and malignant lesions were more visible (55/72 = 76%) than benign (10/30 = 33%). BPE and FGT did not influence visibility of M (p = 0.35 and p = 0.57 respectively) as well as of

  18. Diffusion weighted imaging reflects variable cellularity and stromal density present in breast fibroadenomas

    Science.gov (United States)

    Parsian, Sana; Giannakopoulos, Nadia V.; Rahbar, Habib; Rendi, Mara H.; Chai, Xiaoyu

    2016-01-01

    OBJECTIVE To determine the underlying histopathologic features influencing apparent diffusion coefficient (ADC) values of breast fibroadenomas. MATERIALS AND METHODS Biopsy proven fibroadenomas (n=26) initially identified as suspicious on breast MRI were retrospectively evaluated. Histopathological assessments of lesion cellularity and stromal type were compared with ADC measures on diffusion-weighted MRI. RESULTS Presence of epithelial hyperplasia (increased cellularity) and dense collagenous stroma were both significantly associated with lower lesion ADC values (p=0.02 and 0.004, respectively. CONCLUSION Variations in epithelial cellularity and stromal type influence breast lesion ADC values and may explain the wide range of ADC measures observed in benign fibroadenomas. PMID:27379441

  19. Intratumoral Heterogeneity of Breast Cancer Xenograft Models: Texture Analysis of Diffusion-Weighted MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Cho, Nariya; Li, Mulun; Song, In Chan; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jang, Min Hye; Park, So Yeon; Kim, Bo Young [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kang, Ho Chul [Dept. of Computer Science and Engineering, Seoul National University, Seoul (Korea, Republic of)

    2014-10-15

    To investigate whether there is a relationship between texture analysis parameters of apparent diffusion coefficient (ADC) maps and histopathologic features of MCF-7 and MDA-MB-231 xenograft models. MCF-7 estradiol (+), MCF-7 estradiol (-), and MDA-MB-231 xenograft models were made with approval of the animal care committee. Twelve tumors of MCF-7 estradiol (+), 9 tumors of MCF-7 estradiol (-), and 6 tumors in MDA-MB-231 were included. Diffusion-weighted MR images were obtained on a 9.4-T system. An analysis of the first and second order texture analysis of ADC maps was performed. The texture analysis parameters and histopathologic features were compared among these groups by the analysis of variance test. Correlations between texture parameters and histopathologic features were analyzed. We also evaluated the intraobserver agreement in assessing the texture parameters. MCF-7 estradiol (+) showed a higher standard deviation, maximum, skewness, and kurtosis of ADC values than MCF-7 estradiol (-) and MDA-MB-231 (p < 0.01 for all). The contrast of the MCF-7 groups was higher than that of the MDA-MB-231 (p 0.004). The correlation (COR) of the texture analysis of MCF-7 groups was lower than that of MDA-MB-231 (p < 0.001). The histopathologic analysis showed that Ki-67mean and Ki-67diff of MCF-7 estradiol (+) were higher than that of MCF-7 estradiol (-) or MDA-MB-231 (p < 0.05). The microvessel density (MVD)mean and MVDdiff of MDA-MB-231 were higher than those of MCF-7 groups (p < 0.001). A diffuse-multifocal necrosis was more frequently found in MDA-MB-231 (p < 0.001). The proportion of necrosis moderately correlated with the contrast (r = -0.438, p = 0.022) and strongly with COR (r = 0.540, p 0.004). Standard deviation (r = 0.622, r = 0.437), skewness (r = 0.404, r 0.484), and kurtosis (r = 0.408, r = 0.452) correlated with Ki-67 mean and Ki-67diff (p < 0.05 for all). COR moderately correlated with Ki-67diff (r -0.388, p = 0.045). Skewness (r = -0.643, r = -0

  20. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd

  1. Diffusion-weighted magnetic resonance imaging during radiotherapy of locally advanced cervical cancer - treatment response assessment using different segmentation methods

    DEFF Research Database (Denmark)

    Haack, Søren; Tanderup, Kari; Kallehauge, Jesper Folsted

    2015-01-01

    BACKGROUND: Diffusion-weighted magnetic resonance imaging (DW-MRI) and the derived apparent diffusion coefficient (ADC) value has potential for monitoring tumor response to radiotherapy (RT). Method used for segmentation of volumes with reduced diffusion will influence both volume size and observed......2-weighted MR images using the Jaccard similarity index (JSI). ADC values from segmented volumes were compared and changes of ADC values during therapy were evaluated. RESULTS: Significant difference between the four volumes (GTV, DWIcluster, DWISD4 and DWIregion) was found (p

  2. Does diffusion-weighted imaging add diagnostic confidence in discriminating between benign and malignant solid focal liver lesions?

    Science.gov (United States)

    Girometti, Rossano; Del Pin, Matteo; Pullini, Serena; Cereser, Lorenzo; Como, Giuseppe; Bazzocchi, Massimo; Zuiani, Chiara

    2014-01-01

    We investigated whether diffusion-weighted Imaging (DWI) adds diagnostic confidence in assessing focal liver lesions (FLLs). By reviewing FLLs without and with DWI at 1.5 T, two radiologists scored the confidence in diagnosing benignancy/malignancy (confidence score), and DWI usefulness (usefulness score). We showed that adding DWI significantly decreased the confidence score of the most experienced radiologist and increased his confidence in false-negative diagnoses showing atypical features on conventional magnetic resonance imaging. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. MR Imaging of Orbital Inflammatory Syndrome, Orbital Cellulitis, and Orbital Lymphoid Lesions: The Role of Diffusion-Weighted Imaging

    Science.gov (United States)

    Kapur, R.; Sepahdari, A.R.; Mafee, M.F.; Putterman, A.M.; Aakalu, V.; Wendel, L.J.A.; Setabutr, P.

    2013-01-01

    BACKGROUND AND PURPOSE Orbital inflammatory syndrome (OIS) has clinical features that overlap with orbital lymphoid lesions and orbital cellulitis. Prompt diagnosis is needed in all 3 conditions because the management of each one differs greatly. CT and MR imaging, though useful, do not always distinguish among these conditions. The aim of this study was to identify the role of diffusion-weighted imaging (DWI) in differentiating these 3 diagnoses. MATERIALS AND METHODS A retrospective analysis of orbital MR imaging was conducted. T1- and T2-weighted and postcontrast images were analyzed. Region-of-interest analysis was performed by using measurements in areas of abnormality seen on conventional MR imaging sequences and measurements of the ipsilateral thalamus for each patient. The DWI signal intensity of the lesion was expressed as a percentage of average thalamic intensity in each patient. Similarly, lesion apparent diffusion coefficients (ADCs) and lesion-thalamus ADC ratios were calculated. Statistical significance was determined by the Kruskal-Wallis test, and post hoc pairwise comparisons, by the Mann-Whitney U test for DWI-intensity ratio, ADC, and ADC ratio. RESULTS A significant difference was noted in DWI intensities, ADC, and ADC ratio between OIS, orbital lymphoid lesions, and orbital cellulitis (P cellulitis. Lymphoid lesions showed lower ADC than OIS and cellulitis. A trend was seen toward lower ADC in OIS than in cellulitis (P = .17). CONCLUSIONS DWI may help differentiate OIS from lymphoid lesions and cellulitis and may allow more rapid management. PMID:18842758

  4. The diagnostic value of high-frequency power-based diffusion-weighted imaging in prediction of neuroepithelial tumour grading

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhiye; Liu, Mengqi [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Hainan Branch of Chinese PLA General Hospital, Department of Radiology, Sanya (China); Zhou, Peng [Chinese Academy of Sciences, Research Center for Brain-inspired Intelligence, Institute of Automation, Beijing (China); University of Chinese Academy of Sciences, Beijing (China); Lv, Bin [Academy of Telecommunication Research of MIIT, Beijing (China); Wang, Yan; Wang, Yulin; Lou, Xin; Ma, Lin [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Gui, Qiuping [Chinese PLA General Hospital, Department of Pathology, Beijing (China); He, Huiguang [Chinese Academy of Sciences, Research Center for Brain-inspired Intelligence, Institute of Automation, Beijing (China); University of Chinese Academy of Sciences, Beijing (China); Chinese Academy of Sciences, Center for Excellence in Brain Science and Intelligence Technology, Beijing (China)

    2017-12-15

    To retrospectively evaluate the diagnostic value of high-frequency power (HFP) compared with the minimum apparent diffusion coefficient (MinADC) in the prediction of neuroepithelial tumour grading. Diffusion-weighted imaging (DWI) data were acquired on 115 patients by a 3.0-T MRI system, which included b0 images and b1000 images over the whole brain in each patient. The HFP values and MinADC values were calculated by an in-house script written on the MATLAB platform. There was a significant difference among each group excluding grade I (G1) vs. grade II (G2) (P = 0.309) for HFP and among each group for MinADC. ROC analysis showed a higher discriminative accuracy between low-grade glioma (LGG) and high-grade glioma (HGG) for HFP with area under the curve (AUC) value 1 compared with that for MinADC with AUC 0.83 ± 0.04 and also demonstrated a higher discriminative ability among the G1-grade IV (G4) group for HFP compared with that for MinADC except G1 vs. G2. HFP could provide a simple and effective optimal tool for the prediction of neuroepithelial tumour grading based on diffusion-weighted images in routine clinical practice. (orig.)

  5. The diagnostic value of high-frequency power-based diffusion-weighted imaging in prediction of neuroepithelial tumour grading.

    Science.gov (United States)

    Chen, Zhiye; Zhou, Peng; Lv, Bin; Liu, Mengqi; Wang, Yan; Wang, Yulin; Lou, Xin; Gui, Qiuping; He, Huiguang; Ma, Lin

    2017-12-01

    To retrospectively evaluate the diagnostic value of high-frequency power (HFP) compared with the minimum apparent diffusion coefficient (MinADC) in the prediction of neuroepithelial tumour grading. Diffusion-weighted imaging (DWI) data were acquired on 115 patients by a 3.0-T MRI system, which included b0 images and b1000 images over the whole brain in each patient. The HFP values and MinADC values were calculated by an in-house script written on the MATLAB platform. There was a significant difference among each group excluding grade I (G1) vs. grade II (G2) (P = 0.309) for HFP and among each group for MinADC. ROC analysis showed a higher discriminative accuracy between low-grade glioma (LGG) and high-grade glioma (HGG) for HFP with area under the curve (AUC) value 1 compared with that for MinADC with AUC 0.83 ± 0.04 and also demonstrated a higher discriminative ability among the G1-grade IV (G4) group for HFP compared with that for MinADC except G1 vs. G2. HFP could provide a simple and effective optimal tool for the prediction of neuroepithelial tumour grading based on diffusion-weighted images in routine clinical practice. • HFP shows positive correlation with neuroepithelial tumour grading. • HFP presents a good diagnostic efficacy for LGG and HGG. • HFP is helpful in the selection of brain tumour boundary.

  6. Liver Imaging Reporting and Data System on CT and gadoxetic acid-enhanced MRI with diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Dong Ik; Jang, Kyung Mi; Kim, Seong Hyun; Kang, Tae Wook; Song, Kyoung Doo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of)

    2017-10-15

    To assess major imaging features of Liver Imaging Reporting and Data System (LI-RADS) on contrast-enhanced CT and gadoxetic acid-enhanced MRI and to estimate whether the combination of signal intensity favouring HCC on hepatobiliary phase (HBP) and diffusion-weighted images (DWI) can act as a major feature in LI-RADS. Four hundred twenty one patients with 445 observations were included. Major features of LI-RADS on CT and MRI as well as HBP and DWI features were assessed. Diagnostic performances of LR-5 according to LI-RADS v2014 and modified LI-RADS which incorporate combination of HBP and DWI were assessed. Pairwise comparisons of the receiver operating characteristic (ROC) curves were performed. For HCCs, capsule appearance had the highest rate of discordance between CT and MRI (32.7%), followed by washout appearance (22.2%). Specificity (75%) of LR-5 of LI-RADS v2014 was lower than that (77.1-79.2%) of modified LI-RADS. Area under the ROC curve of modified LI-RADS (0.755-0.775) was not significantly different from that of LI-RADS v 2014 (0.709) (p > 0.05). There were substantial discordances between CT and MRI for capsule and washout appearances in hepatic observations, and combination of gadoxetic acid-enhanced MRI and DWI might be able to be incorporated as a major feature of LI-RADS. (orig.)

  7. Application of EPI diffusion-weighted and Gd-DTPA T2* perfusion imaging in the diagnosis of brain ischemia

    International Nuclear Information System (INIS)

    Han Hongbin; Xie Jingxia

    1998-01-01

    Purpose: To study the MR and CT appearances of brain ischemia on diffusion-weighted imaging (DWI) and evaluate the role of EPI ADC-map, DWI and T 2 * perfusion imaging in acute stroke. Methods: DWI or ADC-map and routine T 1 WI and T 2 WI were performed in 36 patients with stroke (the time after onset of stroke: 2 hours - 2 months). Among them, 12 cases had perfusion imaging simultaneously. Results: Gd-DTPA T 2 * perfusion imaging demonstrated decrease of rrCBV and rrCBF in 10 cases; identical in 1 case and increase in 1 case. The mean transit time in the diseased area was longer than that of the contralateral corresponding region (paired t test: P 2 * perfusion imaging can demonstrate the decrease and restoration of CBF in the brain ischemic regions. DWI and ADC-map are highly valuable in the early diagnosis and monitoring the development of brain ischemic disease

  8. Dependence on b-value of the direction-averaged diffusion-weighted imaging signal in brain.

    Science.gov (United States)

    McKinnon, Emilie T; Jensen, Jens H; Glenn, G Russell; Helpern, Joseph A

    2017-02-01

    The dependence of the direction-averaged diffusion-weighted imaging (DWI) signal in brain was studied as a function of b-value in order to help elucidate the relationship between diffusion weighting and brain microstructure. High angular resolution diffusion imaging (HARDI) data were acquired from two human volunteers with 128 diffusion-encoding directions and six b-value shells ranging from 1000 to 6000s/mm 2 in increments of 1000s/mm 2 . The direction-averaged signal was calculated for each shell by averaging over all diffusion-encoding directions, and the signal was plotted as a function of b-value for selected regions of interest. As a supplementary analysis, similar methods were also applied to retrospective DWI data obtained from the human connectome project (HCP), which includes b-values up to 10,000s/mm 2 . For all regions of interest, a simple power law relationship accurately described the observed dependence of the direction-averaged signal as a function of the diffusion weighting. In white matter, the characteristic exponent was 0.56±0.05, while in gray matter it was 0.88±0.11. Comparable results were found with the HCP data. The direction-averaged DWI signal varies, to a good approximation, as a power of the b-value, for b-values between 1000 and 6000s/mm 2 . The exponents characterizing this power law behavior were markedly different for white and gray matter, indicative of sharply contrasting microstructural environments. These results may inform the construction of microstructural models used to interpret the DWI signal. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient mapping for diagnosing infectious spondylodiscitis: a preliminary study.

    Science.gov (United States)

    Chen, Tai-Yuan; Wu, Te-Chang; Tsui, Yu-Kun; Chen, Hou-Hsun; Lin, Chien-Jen; Lee, Huey-Jen; Wu, Tai-Ching

    2015-01-01

    Though diffusion-weighted (DW) magnetic resonance imaging (MRI) is useful for diagnosing many pathologies, its use in infectious spondylodiscitis is unclear. We aimed to evaluate the use of DW MRI and apparent diffusion coefficient (ADC) mapping for the diagnosis of infectious spondylodiscitis. In this retrospective study, 17 patients with confirmed infectious spondylodiscitis were matched by age and level of infected disc with 17 patients with degenerative disc disease (DDD) and 17 healthy controls. All patients received conventional MRI and diffusion-weighted imaging (DWI) in the same imaging session. ADC values of the 3 groups of patients were compared. The mean age of each group was 67.4 ± 11.6 years. The mean ADCs of the normal control, DDD, and infectious spondylodiscitis groups were 1.76 ± 0.19 × 10(-3) , 1.12 ± 0.22 × 10(-3) , and 1.27 ± 0.38 × 10(-3) mm2 /second, respectively. The ADCs of the DDD and infectious spondylodiscitis groups were both significantly lower than that of the normal control group (both, P spondylodiscitis. © 2014 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  10. Diffusion-weighted imaging of the rat pelvis using 3D water-excitation MP-RAGE MR sequence

    International Nuclear Information System (INIS)

    Numano, Tomokazu; Homma, Kazuhiro; Hyodo, Koji; Nitta, Naotaka; Iwasaki, Nobuaki

    2008-01-01

    We developed a novel technique for fat-saturated, 3-dimensional (3D) diffusion-weighted (DW) magnetic resonance (MR) imaging sequencing based upon the 3D magnetization-prepared, rapid gradient-echo (3D-MP-RAGE) method. We saturated fat using 2 techniques, chemical shift selective (CHESS; FatSat)-3D-DWI sequence versus water excitation (WE)-3D-DWI method, then compared the 2 sequences in terms of degree of fat suppression. In preparing the FatSat-3D-DWI sequence, we used a ''CHESS-90deg radiofrequency (RF)-motion probing gradient (MPG)-180deg RFMPG-90deg RF'' pulse-train, to sensitize the magnetization to fat-saturated diffusion. In contrast, in the WE-3D-DWI sequence, we selected a RAGE-excitation pulse with a binominal-pulse 1-1 or 1-2-1 for water-excited (fat-saturated) diffusion imaging. Experimental results in a phantom confirmed the effects of diffusion weighting and of fat saturation. Fat saturation was much better in the WE-3D-DWI sequence than the CHESS-3D-DWI sequence. From results from animal (rat pelvis) experiments using WE-3D-DWI, we obtained fat-saturated DWI. This sequence was useful for in vivo imaging. (author)

  11. Neural - levelset shape detection segmentation of brain tumors in dynamic susceptibility contrast enhanced and diffusion weighted magnetic resonance images

    International Nuclear Information System (INIS)

    Vijayakumar, C.; Bhargava, Sunil; Gharpure, Damayanti Chandrashekhar

    2008-01-01

    A novel Neuro - level set shape detection algorithm is proposed and evaluated for segmentation and grading of brain tumours. The algorithm evaluates vascular and cellular information provided by dynamic contrast susceptibility magnetic resonance images and apparent diffusion coefficient maps. The proposed neural shape detection algorithm is based on the levels at algorithm (shape detection algorithm) and utilizes a neural block to provide the speed image for the level set methods. In this study, two different architectures of level set method have been implemented and their results are compared. The results show that the proposed Neuro-shape detection performs better in differentiating the tumor, edema, necrosis in reconstructed images of perfusion and diffusion weighted magnetic resonance images. (author)

  12. Diffusion weighted imaging of the uterus: regional ADC variation with oral contraceptive usage and comparison with cervical cancer.

    Science.gov (United States)

    Messiou, Christina; Morgan, Veronica A; De Silva, Sonali S; Ind, Thomas E; deSouza, Nandita M

    2009-07-01

    There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCP. A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (Puterus was significantly greater (Puterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging.

  13. Non-Mono-Exponential Analysis of Diffusion-Weighted Imaging for Treatment Monitoring in Prostate Cancer Bone Metastases.

    Science.gov (United States)

    Reischauer, Carolin; Patzwahl, René; Koh, Dow-Mu; Froehlich, Johannes M; Gutzeit, Andreas

    2017-07-19

    Diffusion-weighted imaging quantified using the mono-exponential model has shown great promise for monitoring treatment response in prostate cancer bone metastases. The aim of this prospective study is to evaluate whether non-mono-exponential diffusion models better describe the water diffusion properties and may improve treatment response assessment. Diffusion-weighted imaging data of 12 treatment-naïve patients with 34 metastases acquired before and at one, two, and three months after initiation of antiandrogen treatment are analysed using the mono-exponential, the intravoxel incoherent motion, the stretched exponential, and the statistical model. Repeatability of the fitted parameters and changes under therapy are quantified. Model preference is assessed and correlation coefficients across times are calculated to delineate the relationship between the prostate-specific antigen levels and the diffusion parameters as well as between the diffusion parameters within each model. There is a clear preference for non-mono-exponential diffusion models at all time points. Particularly the stretched exponential is favoured in approximately 60% of the lesions. Its parameters increase significantly in response to treatment and are highly repeatable. Thus, the stretched exponential may be utilized as a potential optimal model for monitoring treatment response. Compared with the mono-exponential model, it may provide complementary information on tissue properties and improve response assessment.

  14. Multishot diffusion-weighted MR imaging features in acute trauma of spinal cord

    International Nuclear Information System (INIS)

    Zhang, Jin Song; Huan, Yi

    2014-01-01

    To analyse diffusion-weighted MRI of acute spinal cord trauma and evaluate its diagnostic value. Conventional MRI and multishot, navigator-corrected DWI were performed in 20 patients with acute spinal cord trauma using 1.5-T MR within 72 h after the onset of trauma. Twenty cases were classified into four categories according to the characteristics of DWI: (1) Oedema type: ten cases presented with variable hyperintense areas within the spinal cord. There were significant differences in the apparent diffusion coefficients (ADCs) between lesions and unaffected regions (t = -7.621, P < 0.01). ADC values of lesions were markedly lower than those of normal areas. (2) Mixed type: six cases showed heterogeneously hyperintense areas due to a mixture of haemorrhage and oedema. (3) Haemorrhage type: two cases showed lesions as marked hypointensity due to intramedullary haemorrhage. (4) Compressed type (by epidural haemorrhage): one of the two cases showed an area of mild hyperintensity in the markedly compressed cord due to epidural haematoma. Muti-shot DWI of the spinal cord can help visualise and evaluate the injured spinal cord in the early stage, especially in distinguishing the cytotoxic oedema from vasogenic oedema. It can assist in detecting intramedullary haemorrhage and may have a potential role in the evaluation of compressed spinal cord. (orig.)

  15. Multishot diffusion-weighted MR imaging features in acute trauma of spinal cord

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jin Song; Huan, Yi [Fourth Military Medical University, Department of Radiology, Xijing Hospital, Xi' an (China)

    2014-03-15

    To analyse diffusion-weighted MRI of acute spinal cord trauma and evaluate its diagnostic value. Conventional MRI and multishot, navigator-corrected DWI were performed in 20 patients with acute spinal cord trauma using 1.5-T MR within 72 h after the onset of trauma. Twenty cases were classified into four categories according to the characteristics of DWI: (1) Oedema type: ten cases presented with variable hyperintense areas within the spinal cord. There were significant differences in the apparent diffusion coefficients (ADCs) between lesions and unaffected regions (t = -7.621, P < 0.01). ADC values of lesions were markedly lower than those of normal areas. (2) Mixed type: six cases showed heterogeneously hyperintense areas due to a mixture of haemorrhage and oedema. (3) Haemorrhage type: two cases showed lesions as marked hypointensity due to intramedullary haemorrhage. (4) Compressed type (by epidural haemorrhage): one of the two cases showed an area of mild hyperintensity in the markedly compressed cord due to epidural haematoma. Muti-shot DWI of the spinal cord can help visualise and evaluate the injured spinal cord in the early stage, especially in distinguishing the cytotoxic oedema from vasogenic oedema. It can assist in detecting intramedullary haemorrhage and may have a potential role in the evaluation of compressed spinal cord. (orig.)

  16. Diffusion-weighted magnetic resonance imaging of borderzone necrosis in paediatric tuberculous meningitis

    International Nuclear Information System (INIS)

    Omar, Nadir; Pienaar, Manana; Andronikou, Savvas; Van Toorn, Ronald

    2011-01-01

    Tuberculous meningitis (TBM) is associated with borderzone necrosis (BZN) of the brain parenchyma in areas adjacent to meningeal inflammation. Diffusion-weighted MRI (DWI) allows for accurate detection of cytotoxic oedema associated with necrosis. Detection and characterisation of BZN using DWI to explain its pathogenesis in TBM have not been performed previously in children. Our objective was to identify the prevalence and characteristics of BZN using DWI in children with TBM and to correlate it with the presence, degree and distribution of basal meningeal enhancement (BE) in the absence of large-vessel thrombosis. A retrospective descriptive MRI DWI study of 34 children with TBM was conducted. The topography of BZN was compared with the presence and severity of BE on specific MRI sequences. BZN was identified on MRI DWI in 50% of patients of which 82% had involvement of the temporal lobes. The severity and extent of BE in either middle cerebral artery cistern correlated with the presence of BZN (P = 0.02). BZN did not correlate with radiologically detectable vascular occlusion BZN is common in TBM occurring in 50% of children. Detection and confirmation of cytotoxic oedema associated with BZN using DWI, and its clear relation to BE supports existing pathogenetic descriptions. The pathogenesis of BZN differs to that of topographical infarction on the basis of distribution as well as an absent statistical relationship between vascular occlusion and BZN.

  17. Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Takashi; Hori, Masatoshi; Onishi, Hiromitsu; Sakane, Makoto; Tsuboyama, Takahiro; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Nakamoto, Atsushi; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Osaka (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynaecology, Osaka (Japan)

    2017-12-15

    To compare the image quality and diagnostic performance of reduced field-of-view (rFOV) versus conventional full field-of-view (fFOV) diffusion-weighted (DW) imaging of endometrial cancer. Fifty women with endometrial cancer underwent preoperative rFOV and fFOV DW imaging. Two radiologists compared the image qualities of both techniques, and five radiologists assessed superficial and deep myometrial invasion using both techniques. The statistical analysis included the Wilcoxon signed-rank test and paired t-test for comparisons of image quality and mean diagnostic values. Distortion, tumour delineation, and overall image quality were significantly better with rFOV DW imaging, compared to fFOV DW imaging (P < 0.05); however, the former was inferior in noise (P < 0.05). Regarding superficial invasion, the mean accuracies of the techniques did not differ statistically (rFOV, 58.0% versus fFOV, 56.0%; P = 0.30). Regarding deep myometrial invasion, rFOV DW imaging yielded significantly better mean accuracy, specificity, and positive predictive values (88.4%, 97.8%, and 91.7%, respectively), compared with fFOV DW imaging (84.8%, 94.1%, and 77.4%, respectively; P = 0.009, 0.005, and 0.011, respectively). Compared with fFOV DW imaging, rFOV DW imaging yielded less distortion, improved image quality and, consequently, better diagnostic performance for deep myometrial invasion of endometrial cancer. (orig.)

  18. Unsupervised 3D Prostate Segmentation Based on Diffusion-Weighted Imaging MRI Using Active Contour Models with a Shape Prior

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2011-01-01

    plays a crucial role in various clinical applications. Recently, magnetic resonance imaging (MRI is proposed as a promising modality to detect and monitor prostate-related diseases. In this paper, we propose an unsupervised algorithm to segment prostate with 3D apparent diffusion coefficient (ADC images derived from diffusion-weighted imaging (DWI MRI without the need of a training dataset, whereas previous methods for this purpose require training datasets. We first apply a coarse segmentation to extract the shape information. Then, the shape prior is incorporated into the active contour model. Finally, morphological operations are applied to refine the segmentation results. We apply our method to an MR dataset obtained from three patients and provide segmentation results obtained by our method and an expert. Our experimental results show that the performance of the proposed method is quite successful.

  19. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  20. Prediction of pancreatic neuroendocrine tumour grade with MR imaging features: added value of diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lotfalizadeh, Emad; Vullierme, Marie-Pierre; Allaham, Wassim [University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, Centre de Recherche Biomedicale Bichat-Beaujon, CRB3, Paris (France); Wagner, Mathilde [University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); INSERM U1149, Centre de Recherche Biomedicale Bichat-Beaujon, CRB3, Paris (France); Cros, Jerome; Couvelard, Anne [University Paris Diderot, Paris (France); University Hospitals Paris Nord Val de Seine, Department of Pathology, Clichy, Hauts-de-Seine (France); Hentic, Olivia; Ruzniewski, Philippe [University Hospitals Paris Nord Val de Seine, Department of Gastroenterology, Clichy, Hauts-de-Seine (France)

    2017-04-15

    To evaluate the value of MR imaging including diffusion-weighted imaging (DWI) for the grading of pancreatic neuroendocrine tumours (pNET). Between 2006 and 2014, all resected pNETs with preoperative MR imaging including DWI were included. Tumour grading was based on the 2010 WHO classification. MR imaging features included size, T1-w, and T2-w signal intensity, enhancement pattern, apparent (ADC) and true diffusion (D) coefficients. One hundred and eight pNETs (mean 40 ± 33 mm) were evaluated in 94 patients (48 women, 51 %, mean age 52 ± 12). Fifty-five (51 %), 42 (39 %), and 11 (10 %) tumours were given the following grades (G): G1, G2, and G3. Mean ADC and D values were significantly lower as grade increased (ADC: 2.13 ± 0.70, 1.78 ± 0.72, and 0.86 ± 0.22 10{sup -3} mm{sup 2}/s, and D: 1.92 ± 0.70, 1.75 ± 0.74, and 0.82 ± 0.19 10{sup -3} mm{sup 2}/s G1, G2, and G3, all p < 0.001). A higher grade was associated with larger sized tumours (p < 0.001). The AUROC of ADC and D to differentiate G3 and G1-2 were 0.96 ± 0.02 and 0.95 ± 0.02. Optimal cut-off values for the identification of G3 were 1.19 10{sup -3} mm{sup 2}/s for ADC (sensitivity 100 %, specificity 92 %) and 1.04 10{sup -3} mm{sup 2}/s for D (sensitivity 82 %, specificity 92 %). Morphological/functional MRI features of pNETS depend on tumour grade. DWI is useful for the identification of high-grade tumours. (orig.)

  1. [Trial of artifact reduction in body diffusion weighted imaging development and basic examination of "TRacking Only Navigator"(TRON method)].

    Science.gov (United States)

    Horie, Tomohiko; Takahara, Tarou; Ogino, Tetsuo; Okuaki, Tomoyuki; Honda, Masatoshi; Okumura, Yasuhiro; Kajihara, Nao; Usui, Keisuke; Muro, Isao; Imai, Yutaka

    2008-09-20

    In recent years, the utility of body diffusion weighted imaging as represented by diffusion weighted whole body imaging with background body signal suppression (DWIBS), the DWIBS method, is very high. However, there was a problem in the DWIBS method involving the artifact corresponding to the distance of the diaphragm. To provide a solution, the respiratory trigger (RT) method and the navigator echo method were used together. A problem was that scan time extended to the compensation and did not predict the extension rate, although both artifacts were reduced. If we used only navigator real time slice tracking (NRST) from the findings obtained by the DWIBS method, we presumed the artifacts would be ameliorable without the extension of scan time. Thus, the TRacking Only Navigator (TRON) method was developed, and a basic examination was carried out for the liver. An important feature of the TRON method is the lack of the navigator gating window (NGW) and addition of the method of linear interpolation prior to NRST. The method required the passing speed and the distance from the volunteer's diaphragm. The estimated error from the 2D-selective RF pulse (2DSRP) of the TRON method to slice excitation was calculated. The condition of 2D SRP, which did not influence the accuracy of NRST, was required by the movement phantom. The volunteer was scanned, and the evaluation and actual scan time of the image quality were compared with the RT and DWIBS methods. Diaphragm displacement speed and the quantity of displacement were determined in the head and foot directions, and the result was 9 mm/sec, and 15 mm. The estimated error was within 2.5 mm in b-factor 1000 sec/mm(2). The FA of 2DSRP was 15 degrees, and the navigator echo length was 120 mm, which was excellent. In the TRON method, the accuracy of NRST was steady because of line interpolation. The TRON method obtained image quality equal to that of the RT method with the b-factor in the volunteer scanning at short actual

  2. Trial of artifact reduction in body diffusion weighted imaging development and basic examination of 'TRacking Only Navigator' (TRON method)

    International Nuclear Information System (INIS)

    Horie, Tomohiko; Takahara, Tarou; Ogino, Tetsuo

    2008-01-01

    In recent years, the utility of body diffusion weighted imaging as represented by diffusion weighted whole body imaging with background body signal suppression (DWIBS), the DWIBS method, is very high. However, there was a problem in the DWIBS method involving the artifact corresponding to the distance of the diaphragm. To provide a solution, the respiratory trigger (RT) method and the navigator echo method were used together. A problem was that scan time extended to the compensation and did not predict the extension rate, although both artifacts were reduced. If we used only navigator real time slice tracking (NRST) from the findings obtained by the DWIBS method, we presumed the artifacts would be ameliorable without the extension of scan time. Thus, the TRacking Only Navigator (TRON) method was developed, and a basic examination was carried out for the liver. An important feature of the TRON method is the lack of the navigator gating window (NGW) and addition of the method of linear interpolation prior to NRST. The method required the passing speed and the distance from the volunteer's diaphragm. The estimated error from the 2D-selective RF pulse (2DSRP) of the TRON method to slice excitation was calculated. The condition of 2D SRP, which did not influence the accuracy of NRST, was required by the movement phantom. The volunteer was scanned, and the evaluation and actual scan time of the image quality were compared with the RT and DWIBS methods. Diaphragm displacement speed and the quantity of displacement were determined in the head and foot directions, and the result was 9 mm/sec, and 15 mm. The estimated error was within 2.5 mm in b-factor 1000 sec/mm 2 . The FA of 2DSRP was 15 degrees, and the navigator echo length was 120 mm, which was excellent. In the TRON method, the accuracy of NRST was steady because of line interpolation. The TRON method obtained image quality equal to that of the RT method with the b-factor in the volunteer scanning at short actual

  3. Diffusion kurtosis imaging of the liver at 3 Tesla: in vivo comparison to standard diffusion-weighted imaging.

    Science.gov (United States)

    Budjan, Johannes; Sauter, Elke A; Zoellner, Frank G; Lemke, Andreas; Wambsganss, Jens; Schoenberg, Stefan O; Attenberger, Ulrike I

    2018-01-01

    Background Functional techniques like diffusion-weighted imaging (DWI) are gaining more and more importance in liver magnetic resonance imaging (MRI). Diffusion kurtosis imaging (DKI) is an advanced technique that might help to overcome current limitations of DWI. Purpose To evaluate DKI for the differentiation of hepatic lesions in comparison to conventional DWI at 3 Tesla. Material and Methods Fifty-six consecutive patients were examined using a routine abdominal MR protocol at 3 Tesla which included DWI with b-values of 50, 400, 800, and 1000 s/mm 2 . Apparent diffusion coefficient maps were calculated applying a standard mono-exponential fit, while a non-Gaussian kurtosis fit was used to obtain DKI maps. ADC as well as Kurtosis-corrected diffusion ( D) values were quantified by region of interest analysis and compared between lesions. Results Sixty-eight hepatic lesions (hepatocellular carcinoma [HCC] [n = 25]; hepatic adenoma [n = 4], cysts [n = 18]; hepatic hemangioma [HH] [n = 18]; and focal nodular hyperplasia [n = 3]) were identified. Differentiation of malignant and benign lesions was possible based on both DWI ADC as well as DKI D-values ( P values were in the range of 0.04 to < 0.0001). Conclusion In vivo abdominal DKI calculated using standard b-values is feasible and enables quantitative differentiation between malignant and benign liver lesions. Assessment of conventional ADC values leads to similar results when using b-values below 1000 s/mm 2 for DKI calculation.

  4. DWI-ASPECTS (Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Scores) and DWI-FLAIR (Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery) Mismatch in Thrombectomy Candidates: An Intrarater and Interrater Agreement Study.

    Science.gov (United States)

    Fahed, Robert; Lecler, Augustin; Sabben, Candice; Khoury, Naim; Ducroux, Célina; Chalumeau, Vanessa; Botta, Daniele; Kalsoum, Erwah; Boisseau, William; Duron, Loïc; Cabral, Dominique; Koskas, Patricia; Benaïssa, Azzedine; Koulakian, Hasmik; Obadia, Michael; Maïer, Benjamin; Weisenburger-Lile, David; Lapergue, Bertrand; Wang, Adrien; Redjem, Hocine; Ciccio, Gabriele; Smajda, Stanislas; Desilles, Jean-Philippe; Mazighi, Mikaël; Ben Maacha, Malek; Akkari, Inès; Zuber, Kevin; Blanc, Raphaël; Raymond, Jean; Piotin, Michel

    2018-01-01

    We aimed to study the intrarater and interrater agreement of clinicians attributing DWI-ASPECTS (Diffusion-Weighted Imaging-Alberta Stroke Program Early Computed Tomography Scores) and DWI-FLAIR (Diffusion-Weighted Imaging-Fluid Attenuated Inversion Recovery) mismatch in patients with acute ischemic stroke referred for mechanical thrombectomy. Eighteen raters independently scored anonymized magnetic resonance imaging scans of 30 participants from a multicentre thrombectomy trial, in 2 different reading sessions. Agreement was measured using Fleiss κ and Cohen κ statistics. Interrater agreement for DWI-ASPECTS was slight (κ=0.17 [0.14-0.21]). Four raters (22.2%) had a substantial (or higher) intrarater agreement. Dichotomization of the DWI-ASPECTS (0-5 versus 6-10 or 0-6 versus 7-10) increased the interrater agreement to a substantial level (κ=0.62 [0.48-0.75] and 0.68 [0.55-0.79], respectively) and more raters reached a substantial (or higher) intrarater agreement (17/18 raters [94.4%]). Interrater agreement for DWI-FLAIR mismatch was moderate (κ=0.43 [0.33-0.57]); 11 raters (61.1%) reached a substantial (or higher) intrarater agreement. Agreement between clinicians assessing DWI-ASPECTS and DWI-FLAIR mismatch may not be sufficient to make repeatable clinical decisions in mechanical thrombectomy. The dichotomization of the DWI-ASPECTS (0-5 versus 0-6 or 0-6 versus 7-10) improved interrater and intrarater agreement, however, its relevance for patients selection for mechanical thrombectomy needs to be validated in a randomized trial. © 2017 American Heart Association, Inc.

  5. Detection of active sacroiliitis with ankylosing spondylitis through intravoxel incoherent motion diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Ying-hua [Third Affiliated Hospital of Southern Medical University, Academy of Orthopedics, Department of Radiology, Guangzhou (China); Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, Guangzhou (China); Li, Shao-lin; Zhao, Xiang-cheng; Hu, Shao-yong; Liu, Zhen-hua [Third Affiliated Hospital of Southern Medical University, Academy of Orthopedics, Department of Radiology, Guangzhou (China); Liu, Zai-yi; Chen, Xin; Liang, Chang-hong [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, Guangzhou (China); Mei Ms, Ying-jie [Philips Healthcare, Guangzhou (China); Chan, Queenie [Philips Electronics Hong Kong Ltd, Hong Kong (China)

    2015-09-15

    To confirm feasibility and assess intravoxel incoherent motion (IVIM) to differentiate active sacroiliitis and ankylosing spondylitis. Forty-one patients were divided into two groups, an active group (n = 20) and a chronic group (n = 21), according to the Bath Ankylosing Spondylitis (AS) Disease Activity Index (BASDAI) and laboratory parameters. In addition, 21 healthy volunteers were chosen as the control group. Tissue diffusivity (D{sub slow}), perfusion fraction (f), and pseudo-diffusion coefficient (D{sub fast}) values were obtained for all three groups. One-way analysis of variance and receiver operating characteristic analysis were performed for all parameters. There was good interobserver agreement on the measurements between the two observers. The optimal cut-off values (with respective AUC, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio) between active and chronic groups were D{sub slow} = 0.53 x 10{sup -3} mm{sup 2}/s (0.976, 90 %, 95.2 %, 18.9, 0.10) and f = 0.09 (0.545, 20 %, 95.5 %, 4.2, 0.84), and between chronic and control groups were D{sub slow} = 0.22 x 10{sup -3} mm{sup 2}/s (0.517, 9.52 %, 100 %, no number, 0.9) and f = 0.09 (0.935, 95.24 %, 80.95 %, 5, 0.059). D{sub slow} and f of IVIM diffusion-weighted (DW)-MRI in AS show a significant difference in the values of diffusion of water molecules and fractional perfusion-related volume among the three groups. (orig.)

  6. Gas-induced susceptibility artefacts on diffusion-weighted MRI of the rectum at 1.5 T - Effect of applying a micro-enema to improve image quality.

    Science.gov (United States)

    van Griethuysen, Joost J M; Bus, Elyse M; Hauptmann, Michael; Lahaye, Max J; Maas, Monique; Ter Beek, Leon C; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H; Lambregts, Doenja M J

    2018-02-01

    Assess whether application of a micro-enema can reduce gas-induced susceptibility artefacts in Single-shot Echo Planar Imaging (EPI) Diffusion-weighted imaging of the rectum at 1.5 T. Retrospective analysis of n = 50 rectal cancer patients who each underwent multiple DWI-MRIs (1.5 T) from 2012 to 2016 as part of routine follow-up during a watch-and-wait approach after chemoradiotherapy. From March 2014 DWI-MRIs were routinely acquired after application of a preparatory micro-enema (Microlax ® ; 5 ml; self-administered shortly before acquisition); before March 2014 no bowel preparation was given. In total, 335 scans were scored by an experienced reader for the presence/severity of gas-artefacts (on b1000 DWI), ranging from 0 (no artefact) to 5 (severe artefact). A score ≥3 (moderate-severe) was considered a clinically relevant artefact. A random sample of 100 scans was re-assessed by a second independent reader to study inter-observer effects. Scores were compared between the scans performed without and with a preparatory micro-enema using univariable and multivariable logistic regression taking into account potential confounding factors (age/gender, acquisition parameters, MRI-hardware, rectoscopy prior to MRI). Clinically relevant gas-artefacts were seen in 24.3% (no micro-enema) vs. 3.7% (micro-enema), odds ratios were 0.118 in univariable and 0.230 in multivariable regression (P = 0.0005 and 0.0291). Mean severity score (±SD) was 1.19 ± 1.71 (no-enema) vs 0.32 ± 0.77 (micro-enema), odds ratios were 0.321 (P < 0.0001) and 0.489 (P = 0.0461) in uni- and multivariable regression, respectively. Inter-observer agreement was excellent (κ0.85). Use of a preparatory micro-enema shortly before rectal EPI-DWI examinations performed at 1.5 T MRI significantly reduces both the incidence and severity of gas-induced artefacts, compared to examinations performed without bowel preparation. Copyright © 2017 Elsevier B.V. All rights

  7. Is diffusion-weighted imaging a significant indicator of the development of vascularization in hypovascular hepatocellular lesions?

    Science.gov (United States)

    Takara, Kenichi; Saito, Kazuhiro; Saguchi, Toru; Sugimoto, Katsutoshi; Taira, Junichi; Imai, Yasuharu; Moriyasu, Fuminori; Akata, Soichi; Tokuuye, Koichi

    2014-01-01

    The objective was to evaluate the efficacy of diffusion-weighted imaging (DWI) in predicting the development of vascularization in hypovascular hepatocellular lesions (HHLs). Forty-two HHLs that were diagnosed by computed tomographic (CT) arteriography were evaluated retrospectively. The lesion on DWI was classified as isointense, hypointense, or hyperintense. Follow-up studies that included intravenous dynamic CT or magnetic resonance imaging were performed. The 730-day cumulative developments of vascularization in hypointense, isointense, and hyperintense lesions were 17%, 30%, and 40%, respectively. The differences among these developments were not statistically significant. The signal intensity on DWI showed no significant difference in the development of vascularization. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Diffusion weighted MRI by spatiotemporal encoding: Analytical description and in vivo validations

    Science.gov (United States)

    Solomon, Eddy; Shemesh, Noam; Frydman, Lucio

    2013-07-01

    Diffusion-weighted (DW) MRI is a powerful modality for studying microstructure in normal and pathological tissues. The accuracy derived from DW MRI depends on the acquisition of quality images, and on a precise assessment of the b-values involved. Conventional DW MRI tends to be of limited use in regions suffering from large magnetic field or chemical shift heterogeneities, which severely distort the MR images. In this study we propose novel sequences based on SPatio-temporal ENcoding (SPEN), which overcome such shortcomings owing to SPEN's inherent robustness to offsets. SPEN, however, relies on the simultaneous application of gradients and radiofrequency-swept pulses, which may impart different diffusion weightings along the spatial axes. These will be further complicated in DW measurements by the diffusion-sensitizing gradients, and will in general lead to complex, spatially-dependent b-values. This study presents a formalism for analyzing these diffusion-weighted SPEN (dSPEN) data, which takes into account the concomitant effects of adiabatic pulses, of the imaging as well as diffusion gradients, and of the cross-terms between them. These analytical b-values derivations are subject to experimental validations in phantom systems and ex vivo spinal cords. Excellent agreement is found between the theoretical predictions and these dSPEN experiments. The ensuing methodology is then demonstrated by in vivo mapping of diffusion in human breast - organs where conventional k-space DW acquisition methods are challenged by both field and chemical shift heterogeneities. These studies demonstrate the increased robustness of dSPEN vis-à-vis comparable DW echo planar imaging, and demonstrate the value of this new methodology for medium- or high-field diffusion measurements in heterogeneous systems.

  9. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T

    International Nuclear Information System (INIS)

    Rechichi, Gilda; Sironi, Sandro; Galimberti, Stefania; Valsecchi, Maria Grazia; Signorelli, Mauro; Perego, Patrizia

    2010-01-01

    To determine the diagnostic accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging in the preoperative assessment of myometrial invasion by endometrial cancer. In this prospective study, 47 patients with histologically confirmed endometrial cancer underwent preoperative MR imaging and total hysterectomy. The MR protocol included spin-echo multishot T2-weighted, dynamic T1-weighted and DW images acquired with b-values of 0 and 500 s/mm 2 . Myometrial tumour spread was classified as superficial (<50%) or deep (≥50% myometrial thickness). Postoperative histopathological findings served as a reference standard. Indices of diagnostic performance were assessed for each sequence. At histopathological examination, superficial myometrial invasion was found in 34 patients and deep myometrial invasion in 13. In the assessment of tumour invasion, sensitivity, specificity, positive and negative predictive values of T2-weighted images were 92.3%, 76.5%, 60.0% and 96.3%, respectively. The corresponding values for dynamic images were 69.2%, 61.8%, 40.9% and 84.0%, and for DW images 84.6%, 70.6%, 52.4% and 92.3%. T2-weighted and DW imaging proved to be the most accurate techniques for tumour spread determination. DW imaging proved to be accurate in assessing myometrial invasion, and it could replace dynamic imaging as an adjunct to routine T2-weighted imaging for preoperative evaluation of endometrial cancer. (orig.)

  10. Diffusion-weighted MR imaging in laryngeal and hypopharyngeal carcinoma: association between apparent diffusion coefficient and histologic findings.

    Science.gov (United States)

    Driessen, Juliette P; Caldas-Magalhaes, Joana; Janssen, Luuk M; Pameijer, Frank A; Kooij, Nina; Terhaard, Chris H J; Grolman, Wilko; Philippens, Marielle E P

    2014-08-01

    To investigate the relationship between the histologic characteristics of head and neck squamous cell carcinoma and apparent diffusion coefficient (ADC) at diffusion-weighted magnetic resonance (MR) imaging. The institutional ethics committee approved this study and waived informed consent. In head and neck squamous cell carcinoma, local failure after chemotherapy and/or radiation therapy correlates with pretreatment ADC. However, the histopathologic basis of this correlation remains unclear. In this study, 16 patients with head and neck squamous cell carcinoma were enrolled (median age, 60 years; range, 49-78 years). Before undergoing total laryngectomy, patients underwent 1.5-T diffusion-weighted MR imaging. After resection, whole-mount hematoxylin-eosin-stained sections were registered to the MR images. Cellular density; nuclear, cytoplasmic, and stromal area; and nuclear-cytoplasmic ratio within the tumor were calculated by using image-based segmentation on four consecutive slices. Mean ADC of the corresponding tumor region was calculated. Spearman correlations between ADC and histologic characteristics were calculated. ADC was significantly and inversely correlated with cell density (n = 16, r = -0.57, P = .02), nuclear area (n = 12, r = -0.64, P = .03), and nuclear-cytoplasmic ratio (n = 12, r = -0.77, P ≤ .01). ADC was significantly and positively correlated with percentage area of stroma (n = 12, r = 0.69, P = .01). Additionally, the percentage area of stroma was strongly interdependent with the percentage area of nuclei (n = 12, r = -0.97, P ≤ .01). ADC was significantly correlated with cellularity, stromal component, and nuclear-cytoplasmic ratio. The positive correlation of ADC and stromal component suggests that the poor prognostic value of high pretreatment ADC might partly be attributed to the tumor-stroma component, a known predictor of local failure.

  11. Gastrointestinal stromal tumours: Correlation of modified NIH risk stratification with diffusion-weighted MR imaging as an imaging biomarker

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Kim, Seong Hyun; Jang, Kyung Mi; Choi, Dongil; Ha, Sang Yun; Kim, Kyoung-Mee; Kang, Won Ki; Kim, Min Ji

    2015-01-01

    Highlights: • Except size and necrosis, conventional MR findings of GISTs were not significantly different according to the modified NIH criteria. • The ADC values of GISTs were negatively correlated with the modified NIH criteria. • The ADC value can be helpful for the determination of intermediate or high-risk GISTs. - Abstract: Purpose: To evaluate the correlation of risk grade of gastrointestinal stromal tumours (GISTs) based on modified National Institutes of Health (NIH) criteria with conventional magnetic resonance (MR) imaging and diffusion-weighted (DW) imaging. Methods: We included 22 patients with histopathologically proven GISTs in the stomach or small bowel who underwent pre-operative gadoxetic acid-enhanced MR imaging and DW imaging. We retrospectively assessed correlations between morphologic findings, qualitative (signal intensity, consensus from two observers) and quantitative (degree of dynamic enhancement using signal intensity of tumour/muscle ratio and apparent diffusion coefficient [ADC]) values, and the modified NIH criteria for risk stratification. Spearman partial correlation analysis was used to control for tumour size as a confounding factor. The optimal cut-off level of ADC values for intermediate or high risk GISTs was analyzed using a receiver operating characteristic analysis. Results: Except tumour size and necrosis, conventional MR imaging findings, including the degree of dynamic enhancement, were not significantly different according to the modified NIH criteria (p > 0.05). Tumour ADC values were negatively correlated with the modified NIH criteria, before and after adjustment of tumour size (ρ = −0.754; p < 0.001 and ρ = −0.513; p = 0.017, respectively). The optimal cut-off value for the determination of intermediate or high-risk GISTs was 1.279 × 10 −3 mm 2 /s (100% sensitivity, 69.2% specificity, 81.8% accuracy). Conclusion: Except tumour size and necrosis, conventional MR imaging findings did not correlate with

  12. Diagnosis of acute ischemic stroke based on time-to-peak and diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Keisuke; Eguchi, Tsuneyoshi; Sora, Shigeo; Izumi, Masafumi; Hiyama, Hirofumi [Kameda General Hospital, Kamogawa, Chiba (Japan); Ueki, Keisuke [Tokyo Univ. (Japan). Hospital

    2002-07-01

    Rapid and accurate diagnosis of the hemodynamics of the brain is essential for the treatment of acute ischemic stroke. This study investigated whether time-to-peak and diffusion-weighted magnetic resonance (MR) imaging are useful for predicting the course of stroke. Fourteen patients with non-lacunar acute ischemic stroke underwent emergent MR imaging within 24 hours from the onset followed by cerebral angiography and xenon-enhanced computed tomography (CT). Serial CT was obtained to monitor changes in the size and nature of the infarct. Volumes of the abnormal lesions demonstrated on time-to-peak (V{sub T}) or diffusion-weighted (V{sub D}) images were measured, and the ratio of V{sub T} to V{sub D} was calculated. Based on this ratio, patients were classified into three groups: Group 1 (V{sub T}/V{sub D} 0.5-1.5, n=9), Group 2 (V{sub T}/V{sub D}>1.5, n=3), and Group 3 (V{sub T}/V{sub D}<0.5, n=2). The size of the infarct detected as a low-density area on serial CT scans did not change significantly throughout the course in Group 1 patients, but showed enlargement in all three patients in Group 2. Two patients in Group 3 had major trunk occlusion followed by spontaneous reperfusion, and both developed hemorrhagic transformation. Our study showed that classification of ischemic stroke based on the V{sub T}/V{sub D} ratio was predictive of the time course of the infarct, and may be useful in selecting the initial therapeutic procedure immediately after the onset of stroke. (author)

  13. Prediction of pancreatic neuroendocrine tumour grade with MR imaging features: added value of diffusion-weighted imaging.

    Science.gov (United States)

    Lotfalizadeh, Emad; Ronot, Maxime; Wagner, Mathilde; Cros, Jérôme; Couvelard, Anne; Vullierme, Marie-Pierre; Allaham, Wassim; Hentic, Olivia; Ruzniewski, Philippe; Vilgrain, Valérie

    2017-04-01

    To evaluate the value of MR imaging including diffusion-weighted imaging (DWI) for the grading of pancreatic neuroendocrine tumours (pNET). Between 2006 and 2014, all resected pNETs with preoperative MR imaging including DWI were included. Tumour grading was based on the 2010 WHO classification. MR imaging features included size, T1-w, and T2-w signal intensity, enhancement pattern, apparent (ADC) and true diffusion (D) coefficients. One hundred and eight pNETs (mean 40 ± 33 mm) were evaluated in 94 patients (48 women, 51 %, mean age 52 ± 12). Fifty-five (51 %), 42 (39 %), and 11 (10 %) tumours were given the following grades (G): G1, G2, and G3. Mean ADC and D values were significantly lower as grade increased (ADC: 2.13 ± 0.70, 1.78 ± 0.72, and 0.86 ± 0.22 10 -3 mm 2 /s, and D: 1.92 ± 0.70, 1.75 ± 0.74, and 0.82 ± 0.19 10 -3 mm 2 /s G1, G2, and G3, all p < 0.001). A higher grade was associated with larger sized tumours (p < 0.001). The AUROC of ADC and D to differentiate G3 and G1-2 were 0.96 ± 0.02 and 0.95 ± 0.02. Optimal cut-off values for the identification of G3 were 1.19 10 -3 mm 2 /s for ADC (sensitivity 100 %, specificity 92 %) and 1.04 10 -3 mm 2 /s for D (sensitivity 82 %, specificity 92 %). Morphological/functional MRI features of pNETS depend on tumour grade. DWI is useful for the identification of high-grade tumours. • Morphological and functional MRI features of pNETs depend on tumour grade. • Their combination has a high predictive value for grade. • All pNETs should be explored by MR imaging including DWI. • DWI is helpful for identification of high-grade and poorly-differentiated tumours.

  14. Distribution of collateral fibers in the monkey cervical spinal cord detected with diffusion-weighted magnetic resonance imaging

    DEFF Research Database (Denmark)

    Lundell, Henrik; Nielsen, Jens Bo; Ptito, Maurice

    2011-01-01

    Diffusion anisotropy monitored with diffusion-weighted magnetic resonance imaging (DWMRI) is a sensitive marker to monitor developmental or pathological microstructural changes in spinal cord. The white matter is often treated as a unidirectional axonal bundle but collateral fibers branching off...... the main spinal pathways contradicts this assumption and affects the diffusion anisotropy. It is the aim of this study to investigate to what extent collateral fibers are apparent in diffusion tensor data and if collaterals can be detected as individual fiber directions using crossing fiber detection...... in the white matter of the spinal cord is an invalid assumption due to collateral fibers. We also demonstrate that (ii) collateral fibers can be resolved as distinct peaks in the water diffusion propagator in white matter using multi-fiber models. Finally, we show that (iii) crossing fibers are mainly located...

  15. [Examination of upper abdominal region in high spatial resolution diffusion-weighted imaging using 3-Tesla MRI].

    Science.gov (United States)

    Terada, Masaki; Matsushita, Hiroki; Oosugi, Masanori; Inoue, Kazuyasu; Yaegashi, Taku; Anma, Takeshi

    2009-03-20

    The advantage of the higher signal-to-noise ratio (SNR) of 3-Tesla magnetic resonance imaging (3-Tesla) has the possibility of contributing to the improvement of high spatial resolution without causing image deterioration. In this study, we compared SNR and the apparent diffusion coefficient (ADC) value with 3-Tesla as the condition in the diffusion-weighted image (DWI) parameter of the 1.5-Tesla magnetic resonance imaging (1.5-Tesla) and we examined the high spatial resolution images in the imaging method [respiratory-triggering (RT) method and breath free (BF) method] and artifact (motion and zebra) in the upper abdominal region of DWI at 3-Tesla. We have optimized scan parameters based on phantom and in vivo study. As a result, 3-Tesla was able to obtain about 1.5 times SNR in comparison with the 1.5-Tesla, ADC value had few differences. Moreover, the RT method was effective in correcting the influence of respiratory movement in comparison with the BF method, and image improvement by the effective acquisition of SNR and reduction of the artifact were provided. Thus, DWI of upper abdominal region was a useful sequence for the high spatial resolution in 3-Tesla.

  16. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    International Nuclear Information System (INIS)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de; Ind, Thomas E.

    2009-01-01

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  17. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de (Cancer Research UK Clinical Magnetic Resonance Research Group, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)); Ind, Thomas E. (Dept. of Gynaecology and Obstetrics, St George' s Hospital NHS Trust, London (United Kingdom))

    2009-07-15

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  18. A radiological study of cerebral white matter lesions in patients with dementia using diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Shindo, Hiroaki; Hanyu, Haruo; Kakizaki, Dai; Abe, Kimihiko; Takasaki, Masaru

    1999-01-01

    We investigated the changes in water diffusion in the cerebral white matter and the corpus callosum in 12 patients with Binswanger's disease (BD), and 19 patients with Alzheimer's Disease (AD), including 12 without (AD-) and 7 with periventricular hyperintensity (PVH) lesions (AD+), using diffusion-weighted magnetic resonance imaging (MRI). Apparent diffusion coefficients (ADCs) in the anterior and posterior white matter were significantly higher in patients with BD and AD than in 12 age-matched controls. The ADCs were significantly higher in AD (+) than in AD (-) patients. Anisotropic ratios (ARs), defined as diffusion restricted perpendicular to the direction of the nerve fibers, were significantly higher in BD and AD (+) patients, and even in AD (-) patients, than in the controls. ARs in the anterior white matter were significantly higher in BD than in AD (+), while in the posterior white matter the ratios were significantly higher in AD (+) rather than BD patients. The ADCs and ARs in the genu of the corpus callosum were significantly higher in patients with BD and AD (+) compared to the control subjects, while ADCs and ARs in the splenium were significantly higher in patients with AD (+) and AD (-) than in those with BD. These results suggest that mild myelin loss occurs in AD patients even in apparently normal white matter and in the splenium of the corpus callosum. A definite loss of myelin and axons, including incomplete infarction, occurs preferentially in anterior white matter in BD, while in posterior white matter in AD (+), as seen on T2-weighted images as PVH. Studies with diffusion-weighted MRI may allow the characterization of different pathological processes and enable the demonstration of underlying white matter lesion in patients with dementia that cannot be visualized by conventional MRI. (author)

  19. Methodology of diffusion-weighted, diffusion tensor and magnetisation transfer imaging.

    Science.gov (United States)

    Price, S J; Tozer, D J; Gillard, J H

    2011-12-01

    MRI offers a number of opportunities to examine characteristics of tissue well below the spatial resolution of the imaging technique. The best known of these is diffusion imaging, which allows the production of images whose contrast reflects the ability of water molecules to move through the extravascular extracellular space. Less well-known, but increasingly important, is magnetisation transfer imaging, which produces contrast based on the ability of protons to move between the free water pool and local macromolecules. Both of these techniques offer unique information about the microscopic and molecular structure of tumour tissue. This article will briefly review the underlying theory and technical aspects associated with these imaging techniques.

  20. The role of dynamic contrast-enhanced and diffusion weighted magnetic resonance imaging in the female pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Sala, Evis, E-mail: es220@radiol.cam.ac.uk [University Department of Radiology, Box 218, Level 5, Addenbrooke' s Hospital, Hills Road, Cambridge CB2 0QQ (United Kingdom); Rockall, Andrea, E-mail: Andrea.Rockall@bartsandthelondon.nhs.uk [Department of Radiology, St Bartholomew' s Hospital, West Smithfield, London EC1A 7ED (United Kingdom); Rangarajan, Deepa, E-mail: rdrangarajan@googlemail.com [Department of Radiology, Box 218, Addenbrooke' s Hospital, Hills Road, Cambridge CB2 0QQ (United Kingdom); Kubik-Huch, Rahel A., E-mail: rahel.kubik@ksb.ch [Institute of Radiology, Department of Medical Services, Kantonsspital Baden Im Ergel, CH-5404 Baden (Switzerland)

    2010-12-15

    Functional imaging by means of dynamic multiphase contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion weighted magnetic resonance imaging (DW-MRI) is now part of the standard imaging protocols for evaluation of the female pelvis. DCE-MRI and DW-MRI are important MR imaging techniques which enable the radiologist to move from morphological to functional assessment of diseases of the female pelvis. This is mainly due to the limitations of morphologic imaging, particularly in lesion characterization, accurate lymph node staging, assessment of tumour response and inability to differentiate post-treatment changes from tumour recurrence. DCE-MRI improves the accuracy of T2WI in staging of endometrial cancer. It also helps differentiate tumour recurrence from radiation fibrosis in patients with cervical cancer. DCE-MRI improves characterization of cystic adnexal lesions and detection of small peritoneal implants in patients with ovarian cancer. DW-MRI is valuable in preoperative staging of patients with endometrial and cervical cancer, especially in detection of extra-uterine disease. It does increase reader's confidence for detection of recurrent disease in gynaecological malignancies and improves detection of small peritoneal implants in patients with ovarian cancer. In this review article we give an overview of both DCE-MRI and DW-MRI techniques, concentrating on their main clinical application in the female pelvis, and present a practical approach of the added value of these techniques according to the main pathological conditions, highlighting the pearls and pitfalls of each technique.

  1. IgG4-related kidney disease: MRI findings with emphasis on the usefulness of diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bohyun; Kim, Jin Hee, E-mail: kimjhrad@amc.seoul.kr; Byun, Jae Ho; Kim, Hyoung Jung; Lee, Seung Soo; Kim, So Yeon; Lee, Moon-Gyu

    2014-07-15

    Objectives: To investigate the imaging findings of immunoglobulin G4 (IgG4)-related kidney disease (IgG4-KD) on magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) and to evaluate the usefulness of DWI in lesion detection. Methods: This retrospective cohort study included 31 patients with IgG4-KD who underwent MRI covering both kidneys. Two radiologists reviewed in consensus the MR images to determine the distribution pattern (location, laterality, and multiplicity) and the visually assessed signal intensity (hypointense, isointense or hyperintense) of the renal lesions compared to the normal renal parenchyma on each sequence. Per-patient sensitivity for detecting IgG4-KD and the number of detectable lesions were compared in T2-weighted images, DWI, and dynamic contrast-enhanced images. Results: IgG4-KD typically manifested as bilateral (83.9%), multiple (93.5%), and renal parenchymal (87.1%) nodules appearing isointense (93.5%) on T1-weighted images, hypointense (77.4%) on T2-weighted images, hyperintense (100%) on DWI (b = 1000), and hypointense (83.3%) in the arterial phase and with a progressive enhancement pattern on dynamic contrast-enhanced images. The sensitivity of DWI for detecting IgG4-KD was significantly higher than that of T2-weighted images (100% vs. 77.4%, P = 0.034). The median number of detectable lesions was significantly greater in DWI (n = 9) than in T2-weighted images (n = 2) and dynamic contrast-enhanced images (n = 5) (P ≤ 0.008). Conclusions: The characteristic MRI findings of IgG4-KD were bilateral, multiple, renal parenchymal nodules with T2 hypointensity, diffusion restriction, and a progressive enhancement pattern. As DWI was useful in the detection of IgG4-KD, adding DWI to conventional MRI for patients suspected of having IgG4-KD may enhance the diagnosis.

  2. Pitfalls and Limitations of Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Urinary Bladder Cancer

    Directory of Open Access Journals (Sweden)

    Wei-Ching Lin

    2015-06-01

    Full Text Available Adequately selecting a therapeutic approach for bladder cancer depends on accurate grading and staging. Substantial inaccuracy of clinical staging with bimanual examination, cystoscopy, and transurethral resection of bladder tumor has facilitated the increasing utility of magnetic resonance imaging to evaluate bladder cancer. Diffusion-weighted imaging (DWI is a noninvasive functional magnetic resonance imaging technique. The high tissue contrast between cancers and surrounding tissues on DWI is derived from the difference of water molecules motion. DWI is potentially a useful tool for the detection, characterization, and staging of bladder cancers; it can also monitor posttreatment response and provide information on predicting tumor biophysical behaviors. Despite advancements in DWI techniques and the use of quantitative analysis to evaluate the apparent diffusion coefficient values, there are some inherent limitations in DWI interpretation related to relatively poor spatial resolution, lack of cancer specificity, and lack of standardized image acquisition protocols and data analysis procedures that restrict the application of DWI and reproducibility of apparent diffusion coefficient values. In addition, inadequate bladder distension, artifacts, thinness of bladder wall, cancerous mimickers of normal bladder wall and benign lesions, and variations in the manifestation of bladder cancer may interfere with diagnosis and monitoring of treatment. Recognition of these pitfalls and limitations can minimize their impact on image interpretation, and carefully applying the analyzed results and combining with pathologic grading and staging to clinical practice can contribute to the selection of an adequate treatment method to improve patient care.

  3. Pitfalls and Limitations of Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Urinary Bladder Cancer

    Science.gov (United States)

    Lin, Wei-Ching; Chen, Jeon-Hor

    2015-01-01

    Adequately selecting a therapeutic approach for bladder cancer depends on accurate grading and staging. Substantial inaccuracy of clinical staging with bimanual examination, cystoscopy, and transurethral resection of bladder tumor has facilitated the increasing utility of magnetic resonance imaging to evaluate bladder cancer. Diffusion-weighted imaging (DWI) is a noninvasive functional magnetic resonance imaging technique. The high tissue contrast between cancers and surrounding tissues on DWI is derived from the difference of water molecules motion. DWI is potentially a useful tool for the detection, characterization, and staging of bladder cancers; it can also monitor posttreatment response and provide information on predicting tumor biophysical behaviors. Despite advancements in DWI techniques and the use of quantitative analysis to evaluate the apparent diffusion coefficient values, there are some inherent limitations in DWI interpretation related to relatively poor spatial resolution, lack of cancer specificity, and lack of standardized image acquisition protocols and data analysis procedures that restrict the application of DWI and reproducibility of apparent diffusion coefficient values. In addition, inadequate bladder distension, artifacts, thinness of bladder wall, cancerous mimickers of normal bladder wall and benign lesions, and variations in the manifestation of bladder cancer may interfere with diagnosis and monitoring of treatment. Recognition of these pitfalls and limitations can minimize their impact on image interpretation, and carefully applying the analyzed results and combining with pathologic grading and staging to clinical practice can contribute to the selection of an adequate treatment method to improve patient care. PMID:26055180

  4. Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection

    Energy Technology Data Exchange (ETDEWEB)

    Borens, Bruno [Polyclinique Santa Maria, Nice (France); Arvanitakis, Marianna; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques [Erasme Hospital, Department of Gastroenterology, Brussels (Belgium); Absil, Julie; Matos, Celso; Bali, Maria Antonietta [Erasme Hospital, Department of Radiology, Brussels (Belgium); El Bouchaibi, Said [Epicura, Ath (Belgium)

    2017-03-15

    To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC). Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm{sup 2}) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance. For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P >.05). ADC were lower in infected versus non-infected PFCs (P ≤.031). Minimum ADC cut-off: 1,090 x 10{sup -3} mm{sup 2}/s for reader 1 and 1,012 x 10{sup -3} mm{sup 2}/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers). Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. (orig.)

  5. Diagnostic performance of diffusion-weighted MR imaging in differentiation of diabetic osteoarthropathy and osteomyelitis in diabetic foot

    International Nuclear Information System (INIS)

    Abdel Razek, Ahmed Abdel Khalek; Samir, Sieza

    2017-01-01

    Highlights: • Excellent inter-observer agreement of ADC of bony lesions in diabetic foot. • ADC can differentiate diabetic osteoarthropathy from osteomylitis. • Diffusion MR imaging can added to routine MR imaging of diabetic foot. - Abstract: Purpose: To study the diagnostic performance of diffusion weighted MR imaging in differentiation of diabetic osteoarthropathy and osteomyelitis in diabetic foot. Patients and methods: This prospective study was carried out on 41 patients with diabetic foot, 22 males and 19 females with mean age of 51 years. They underwent diffusion-weighted MR imaging of the foot. The apparent diffusion coefficient (ADC) values of the bony lesions were calculated by two reviewers and correlated with the surgical findings or biopsy. The kappa statistic (k) was used to estimate the proportion of inter-observer agreement of two reviewers. Results: The mean ADC of acute diabetic osteoarthropathy was 1.27 ± 0.19 × 10 −3 mm 2 /s for reviewer 1 and 1.26 ± 0.21 × 10 −3 mm 2 /s for reviewer 2. The mean ADC value in diabetic osteomyelitis was 0.86 ± 0.11 × 10 −3 mm 2 /s for reviewer 1 and 0.85 ± 0.12 × 10 −3 mm 2 /s for reviewer 2. There was excellent inter-observer agreement of ADC value of bony lesions in diabetic foot by both reviewers (K = 0.93). There was statistically significant difference in the ADC values of both groups (P = 0.001). The cut-off point of ADC value of both reviewers used in differentiating acute diabetic osteoarthropathy and osteomyelitis were 0.98 × 10 −3 mm 2 /s and 1.04 × 10 −3 mm 2 /s with an accuracy of 94% and 93% and area under the curve of 0.94 and 0.93 respectively. Conclusion: We conclude that the ADC value is a non-invasive imaging parameter that can help in differentiation of diabetic osteoarthropathy from osteomyelitis with excellent inter-observer agreement.

  6. Diagnostic performance of diffusion-weighted MR imaging in differentiation of diabetic osteoarthropathy and osteomyelitis in diabetic foot

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Razek, Ahmed Abdel Khalek, E-mail: arazek@mans.edu.eg; Samir, Sieza, E-mail: Sieza_s@mans.edu.eg

    2017-04-15

    Highlights: • Excellent inter-observer agreement of ADC of bony lesions in diabetic foot. • ADC can differentiate diabetic osteoarthropathy from osteomylitis. • Diffusion MR imaging can added to routine MR imaging of diabetic foot. - Abstract: Purpose: To study the diagnostic performance of diffusion weighted MR imaging in differentiation of diabetic osteoarthropathy and osteomyelitis in diabetic foot. Patients and methods: This prospective study was carried out on 41 patients with diabetic foot, 22 males and 19 females with mean age of 51 years. They underwent diffusion-weighted MR imaging of the foot. The apparent diffusion coefficient (ADC) values of the bony lesions were calculated by two reviewers and correlated with the surgical findings or biopsy. The kappa statistic (k) was used to estimate the proportion of inter-observer agreement of two reviewers. Results: The mean ADC of acute diabetic osteoarthropathy was 1.27 ± 0.19 × 10{sup −3} mm{sup 2}/s for reviewer 1 and 1.26 ± 0.21 × 10{sup −3} mm{sup 2}/s for reviewer 2. The mean ADC value in diabetic osteomyelitis was 0.86 ± 0.11 × 10{sup −3} mm{sup 2}/s for reviewer 1 and 0.85 ± 0.12 × 10{sup −3} mm{sup 2}/s for reviewer 2. There was excellent inter-observer agreement of ADC value of bony lesions in diabetic foot by both reviewers (K = 0.93). There was statistically significant difference in the ADC values of both groups (P = 0.001). The cut-off point of ADC value of both reviewers used in differentiating acute diabetic osteoarthropathy and osteomyelitis were 0.98 × 10{sup −3} mm{sup 2}/s and 1.04 × 10{sup −3} mm{sup 2}/s with an accuracy of 94% and 93% and area under the curve of 0.94 and 0.93 respectively. Conclusion: We conclude that the ADC value is a non-invasive imaging parameter that can help in differentiation of diabetic osteoarthropathy from osteomyelitis with excellent inter-observer agreement.

  7. High and ultra-high b-value diffusion-weighted imaging in prostate cancer: a quantitative analysis.

    Science.gov (United States)

    Wetter, Axel; Nensa, Felix; Lipponer, Christine; Guberina, Nika; Olbricht, Tobias; Schenck, Marcus; Schlosser, Thomas W; Gratz, Marcel; Lauenstein, Thomas C

    2015-08-01

    Diffusion-weighted imaging (DWI) is routinely used in magnetic resonance imaging (MRI) of prostate cancer. However, the routine use of b values higher than 1000 s/mm(2) is not clear up to present. Moreover, the complex diffusion behavior of malignant and benign prostate tissues hampers precise predictions of contrast in DWI images and apparent diffusion coefficient (ADC) maps. To quantitatively analyze DWI with different b values in prostate cancer and to identify b values best suitable for cancer detection. Forty-one patients with histologically proven prostate cancer were examined with high resolution T2-weighted imaging and DWI at 3 Tesla. Five different b values (0, 800, 1000, 1500, 2000 s/mm(2)) were applied. ADC values of tumors and reference areas were measured on ADC maps derived from different pairs of b values. Furthermore, signal intensities of DW images of tumors and reference areas were measured. For analysis, contrast ratios of ADC values and signal intensities of DW images were calculated and compared. No significant differences were found between contrast ratios measured on ADC maps of all analyzed b value pairs (P = 0.43). Contrast ratios calculated from signal intensities of DW images were highest at b values of 1500 and 2000 s/mm(2) and differed significantly from contrast ratios at b values of 800 and 1000 s/mm(2) (P values, contrast ratios of DW images are significantly higher at b-values of 1500 and 2000 s/mm(2) in comparison to b values of 800 and 1000 s/mm(2). Therefore, diagnostic performance of DWI in prostate cancer might be increased by application of b values higher than 1000 s/mm(2). © The Foundation Acta Radiologica 2014.

  8. Necrotic cervical nodes: Usefulness of diffusion-weighted MR imaging in the differentiation of suppurative lymphadenitis from malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroki, E-mail: hkato@gifu-u.ac.jp [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Kanematsu, Masayuki, E-mail: masa_gif@yahoo.co.jp [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); High-level Imaging Diagnosis Center, Gifu University Hospital, Gifu (Japan); Kato, Zenichiro, E-mail: zenkato@mac.com [Department of Pediatrics, Gifu University School of Medicine, Gifu (Japan); Teramoto, Takahide, E-mail: t-tera@gifu-u.ac.jp [Department of Pediatrics, Gifu University School of Medicine, Gifu (Japan); Mizuta, Keisuke, E-mail: kmizuta@gifu-u.ac.jp [Department of Otolaryngology, Gifu University School of Medicine, Gifu (Japan); Aoki, Mitsuhiro, E-mail: aoki@gifu-u.ac.jp [Department of Otolaryngology, Gifu University School of Medicine, Gifu (Japan); Makita, Hiroki, E-mail: makitah@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan); Kato, Keizo, E-mail: keizo@gifu-u.ac.jp [Department of Oral and Maxillofacial Sciences, Gifu University School of Medicine, Gifu (Japan)

    2013-01-15

    Purpose: The purpose of this study was to assess the efficacy of diffusion-weighted (DW) MR imaging for the differentiation between suppurative lymphadenitis and malignancy in necrotic cervical lymph nodes. Materials and methods: Fifteen patients with suppurative lymphadenitis, 40 with squamous cell carcinoma (SCC), eight with lymphoma, and six with thyroid cancer were accompanied by necrotic cervical nodes. All 69 patients underwent 1.5-T MR imaging including DW and 58 underwent gadolinium-enhanced MR imaging. Necrotic area-to-spinal cord signal intensity ratios (SIR) on T1-, T2- and DW images and apparent diffusion coefficients (ADCs) [10{sup −3} mm{sup 2}/s] were correlated with the pathologies. Results: Nineteen necrotic cervical nodes with suppurative lymphadenitis, 67 with SCC, 10 with lymphoma, and 12 with thyroid cancer were identified. SIR on DW images was higher in suppurative lymphadenitis (2.50 ± 1.21) than in malignancies (1.29 ± 0.67) (p < .01), and ADC value was lower in suppurative lymphadenitis (0.89 ± 0.21) than in malignancies (1.46 ± 0.46) (p < .01). SIR on T1-weighted images was higher in thyroid cancer (1.95 ± 0.53) than in suppurative lymphadenitis (0.87 ± 0.17), SCC (0.92 ± 0.13), and lymphoma (0.95 ± 0.09) (p < .01). No significant difference in SIR on T2-weighted images was found between suppurative lymphadenitis (1.46 ± 0.50) and malignancies (1.61 ± 0.56). Conclusion: DW imaging with ADC measurements may play a supplementary role in the differentiation of necrotic cervical nodes between suppurative lymphadenitis and malignancy.

  9. Multivariate General Linear Models (MGLM) on Riemannian Manifolds with Applications to Statistical Analysis of Diffusion Weighted Images.

    Science.gov (United States)

    Kim, Hyunwoo J; Adluru, Nagesh; Collins, Maxwell D; Chung, Moo K; Bendlin, Barbara B; Johnson, Sterling C; Davidson, Richard J; Singh, Vikas

    2014-06-23

    Linear regression is a parametric model which is ubiquitous in scientific analysis. The classical setup where the observations and responses, i.e., ( x i , y i ) pairs, are Euclidean is well studied. The setting where y i is manifold valued is a topic of much interest, motivated by applications in shape analysis, topic modeling, and medical imaging. Recent work gives strategies for max-margin classifiers, principal components analysis, and dictionary learning on certain types of manifolds. For parametric regression specifically, results within the last year provide mechanisms to regress one real-valued parameter, x i ∈ R , against a manifold-valued variable, y i ∈ . We seek to substantially extend the operating range of such methods by deriving schemes for multivariate multiple linear regression -a manifold-valued dependent variable against multiple independent variables, i.e., f : R n → . Our variational algorithm efficiently solves for multiple geodesic bases on the manifold concurrently via gradient updates. This allows us to answer questions such as: what is the relationship of the measurement at voxel y to disease when conditioned on age and gender. We show applications to statistical analysis of diffusion weighted images, which give rise to regression tasks on the manifold GL ( n )/ O ( n ) for diffusion tensor images (DTI) and the Hilbert unit sphere for orientation distribution functions (ODF) from high angular resolution acquisition. The companion open-source code is available on nitrc.org/projects/riem_mglm.

  10. Correlation of brain stem diffusion-weighted imaging score with vertebrobasilar artery stenosis in patients with acute brain stem infarction

    Directory of Open Access Journals (Sweden)

    Jing-sheng YU

    2015-07-01

    Full Text Available Objective To investigate the correlation of brain stem diffusion-weighted imaging (DWI lesion score with vertebrobasilar artery stenosis as revealed by magnetic resonance angiography (MRA in patients with acute brain stem infarction. Methods A total of 253 patients diagnosed as acute brain stem infarction by means of brain magnetic resonance imaging were analyzed retrospectively. Of them 211 patients were enrolled in the present study, and they were qualified with the enrolling standard, and they underwent examination of brain DWI and MRA simultaneously. The DWI lesion scores and imaging data were analyzed comparatively and statistically. Results Significant correlation was found between DWI lesion score and the main trunk stenosis degree of vertebrobasilar artery in patients with acute brain stem infarction (P=0.009. An increase in overall stenosis degree was found along with an increase in DWI lesion score (P=0.005. When the DWI lesion score was ≥4, occlusion of the main trunk of vertebrobasilar artery could be predicted with sensitivity of 74.5% and specificity of 93.2%, respectively (P=0.000. Conclusions  The DWI lesion score increases as the degree of main trunk stenosis of vertebrobasilar artery increased in patients with acute brain stem infarction. The DWI lesion score, in certain extent, may predict the existence and degree of stenosis of the main trunk of vertebrobasilar artery. DOI: 10.11855/j.issn.0577-7402.2015.06.04

  11. Lymphoma and inflammation in the orbit: Diagnostic performance with diffusion-weighted imaging and dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Sun, Bo; Song, Liyuan; Wang, Xinyan; Li, Jing; Xian, Junfang; Wang, Feifei; Tan, Pan

    2017-05-01

    To investigate the diagnostic performance of diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), and the combination of both in the differential diagnosis of lymphoma and inflammation in the orbit. This retrospective study was approved by the Institutional Review Board and the informed consent requirement was waived. A total of 53 patients underwent preoperative 3T MRI. Parameters of DWI and DCE MRI were evaluated in these 30 patients with orbital lymphoma and 23 patients with orbital inflammation. The diagnostic performance was evaluated using receiver operating characteristic curve analysis. Apparent diffusion coefficient (ADC) values and parameters derived from DCE MRI of orbital lymphoma and orbital inflammation differed significantly (ADC, T max , contrast index [CI], enhancement ratio [ER], and washout ratio [WR]: P inflammation (P = 0.016 for reviewer 1; P = 0.001 for reviewer 2). The combination of DWI and DCE MRI can improve diagnostic performance in differentiating lymphoma from inflammation in the orbit compared with DWI alone. 3 J. MAGN. RESON. IMAGING 2017;45:1438-1445. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Multi-component fiber track modelling of diffusion-weighted magnetic resonance imaging data

    Directory of Open Access Journals (Sweden)

    Yasser M. Kadah

    2010-01-01

    Full Text Available In conventional diffusion tensor imaging (DTI based on magnetic resonance data, each voxel is assumed to contain a single component having diffusion properties that can be fully represented by a single tensor. Even though this assumption can be valid in some cases, the general case involves the mixing of components, resulting in significant deviation from the single tensor model. Hence, a strategy that allows the decomposition of data based on a mixture model has the potential of enhancing the diagnostic value of DTI. This project aims to work towards the development and experimental verification of a robust method for solving the problem of multi-component modelling of diffusion tensor imaging data. The new method demonstrates significant error reduction from the single-component model while maintaining practicality for clinical applications, obtaining more accurate Fiber tracking results.

  13. Diffusion-weighted Magnetic Resonance Imaging in the Early Diagnosis of Neonatal Adrenoleukodystrophy

    Directory of Open Access Journals (Sweden)

    R Nuri Sener

    2011-01-01

    Full Text Available A newborn baby girl developed seizures right after birth. On the fourth day, the baby was examined using diffusion sequence magnetic resonance imaging (MRI and diagnosed to have neonatal adrenoleukodystrophy. Laboratory findings confirmed the diagnosis. This is the first case of neonatal adrenoleukodystrophy (NALD where diffusion MRI sequence helped in the diagnosis. We find association of NALD with seizures at birth is an extremely rare occurrence, and so far, only one case has been mentioned in the literature.

  14. Evolution of Diffusion-Weighted Magnetic Resonance Imaging Signal Abnormality in Sporadic Creutzfeldt-Jakob Disease, With Histopathological Correlation.

    Science.gov (United States)

    Eisenmenger, Laura; Porter, Marie-Claire; Carswell, Christopher J; Thompson, Andrew; Mead, Simon; Rudge, Peter; Collinge, John; Brandner, Sebastian; Jäger, Hans R; Hyare, Harpreet

    2016-01-01

    Prion diseases represent the archetype of brain diseases caused by protein misfolding, with the most common subtype being sporadic Creutzfeldt-Jakob disease (sCJD), a rapidly progressive dementia. Diffusion-weighted imaging (DWI) has emerged as the most sensitive magnetic resonance imaging (MRI) sequence for the diagnosis of sCJD, but few studies have assessed the evolution of MRI signal as the disease progresses. To assess the natural history of the MRI signal abnormalities on DWI in sCJD to improve our understanding of the pathogenesis and to investigate the potential of DWI as a biomarker of disease progression, with histopathological correlation. Gray matter involvement on DWI was assessed among 37 patients with sCJD in 26 cortical and 5 subcortical subdivisions per hemisphere using a semiquantitative scoring system of 0 to 2 at baseline and follow-up. A total brain score was calculated as the summed scores in the individual regions. In 7 patients, serial mean diffusivity measurements were obtained. Age at baseline MRI, disease duration, atrophy, codon 129 methionine valine polymorphism, Medical Research Council Rating Scale score, and histopathological findings were documented. The study setting was the National Prion Clinic, London, England. All participants had a probable or definite diagnosis of sCJD and had at least 2 MRI studies performed during the course of their illness. The study dates were October 1, 2008 to April 1, 2012. The dates of our analysis were January 19 to April 20, 2012. Correlation of regional and total brain scores with disease duration. Among the 37 patients with sCJD in this study there was a significant increase in the number of regions demonstrating signal abnormality during the study period, with 59 of 62 regions showing increased signal intensity (SI) at follow-up, most substantially in the caudate and putamen (P disease duration (r = 0.47, P = .003 at baseline and r = 0.35, P = .03 at follow-up), and the left

  15. Diagnostic accuracy of diffusion weighted magnetic resonance imaging in malignant breast lesions, keeping histopathology as gold standard

    International Nuclear Information System (INIS)

    Sidiq, T.; Ullah, H.

    2017-01-01

    Objective: To determine the diagnostic accuracy of Diffusion Weighted Magnetic Resonance Imaging/Apparent and Diffusion Coefficient (DWI/ADC sequences) in malignant breast lesions taking histopathology as gold standard. Study Design: Cross-sectional validation study. Place and Duration of Study: Combined Military Hospitals Quetta & Peshawar, from Sep 2013 to Mar 2015 and Armed Forces Institute of Radiology and Imaging Rawalpindi, from Apr 2015 to Dec 2015. Material and Methods: After informed consent, patients scheduled for biopsy of a suspicious breast lesion on sonomammography and/or mammography (BIRADS IV & V), fulfilling the inclusion criteria were evaluated with breast MRI including Diffusion Weighted Imaging (DWI) sequence using b-values of 0 & 750 mm2/sec. Apparent Diffusion Coefficient (ADC) values for the breast lesions were also calculated. MRI findings were correlated with histopathological results. Results: A total of 299 cases were included in the study. Mean age of the study population was 45.73 years (SD ± 15.02) with a range of 18 to 89 years. On histopathology 77.9% (n=233) lesions turned to be malignant and 22.1% (n=66) were benign. On DWI 73% (n=219) lesions showed restricted diffusion and were labeled malignant while 27% (n=80) lesions showed facilitated diffusion and were considered benign. The mean apparent diffusion coefficient value of the malignant breast lesions was significantly lower than that of the benign breast lesions (p-value<0.001). The calculated sensitivity, specificity, positive predictive value and negative predictive values of DWI/ADC mapping in differentiating between malignant and benign lesions were 92.2%, 93.9%, 98.1% and 77.5% respectively. The diagnostic accuracy was found to be 92.6%. Conclusion: DWI is a non-invasive diagnostic modality for diagnosing malignant breast lesions. It can be used to reduce the number of unnecessary biopsies and it may help in reaching a definite diagnosis in cases where a suspicious breast

  16. Co-analysis of brain structure and function using fMRI and diffusion-weighted imaging.

    Science.gov (United States)

    Phillips, Jeffrey S; Greenberg, Adam S; Pyles, John A; Pathak, Sudhir K; Behrmann, Marlene; Schneider, Walter; Tarr, Michael J

    2012-11-08

    The study of complex computational systems is facilitated by network maps, such as circuit diagrams. Such mapping is particularly informative when studying the brain, as the functional role that a brain area fulfills may be largely defined by its connections to other brain areas. In this report, we describe a novel, non-invasive approach for relating brain structure and function using magnetic resonance imaging (MRI). This approach, a combination of structural imaging of long-range fiber connections and functional imaging data, is illustrated in two distinct cognitive domains, visual attention and face perception. Structural imaging is performed with diffusion-weighted imaging (DWI) and fiber tractography, which track the diffusion of water molecules along white-matter fiber tracts in the brain (Figure 1). By visualizing these fiber tracts, we are able to investigate the long-range connective architecture of the brain. The results compare favorably with one of the most widely-used techniques in DWI, diffusion tensor imaging (DTI). DTI is unable to resolve complex configurations of fiber tracts, limiting its utility for constructing detailed, anatomically-informed models of brain function. In contrast, our analyses reproduce known neuroanatomy with precision and accuracy. This advantage is partly due to data acquisition procedures: while many DTI protocols measure diffusion in a small number of directions (e.g., 6 or 12), we employ a diffusion spectrum imaging (DSI)(1, 2) protocol which assesses diffusion in 257 directions and at a range of magnetic gradient strengths. Moreover, DSI data allow us to use more sophisticated methods for reconstructing acquired data. In two experiments (visual attention and face perception), tractography reveals that co-active areas of the human brain are anatomically connected, supporting extant hypotheses that they form functional networks. DWI allows us to create a "circuit diagram" and reproduce it on an individual-subject basis

  17. Echo-planar MR cerebral blood volume mapping of glomas. Clinical utility

    International Nuclear Information System (INIS)

    Aronen, H.J.; Univ. Central Hospital, Helsinki; Glass, J.; Pardo, F.S.; Belliveau, J.W.; Gruber, M.L.; Buchbinder, B.R.; Gazit, I.E.; Linggood, R.M.; Fischman, A.J.; Rosen, F.S.; Hochberg, F.H.

    1995-01-01

    Neovascularization is a common phenomenon in gliomas. MR imaging cerebral blood volume (CBV) mapping utilizes ultrafast echo-planar imaging and simultaneous use of gadolinium-based contrast material. To determine the utility of MR CBV mapping in the clinical evaluation of gliomas, we followed 15 patients with serial studies. This technique provided functional information that was not evident with conventional CT or MR imaging. Low-grade tumors demonstrated homogeneously low CBV, while high-grade tumors often showed areas of both high and low CBV. The maximum tumor CBV/white matter ratio was compared between low- (n=3) and high-grade gliomas (n=5) in patients without previous treatment and with histologic verification (n=8) and was significantly higher in high-grade gliomas (p<0.01), High CBV foci in nonenhancing tumor areas were present in 2 cases. The distinction between radiation necrosis and active tumor could be made correctly in 3 of 4 cases. The information provided by MR CBV mapping has the potential to be an adjunct in the clinical care of glioma patients. (orig.)

  18. Prediction of Early Response to Chemotherapy in Lung Cancer by Using Diffusion-Weighted MR Imaging

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2014-01-01

    Full Text Available Purpose. To determine whether change of apparent diffusion coefficient (ADC value could predict early response to chemotherapy in lung cancer. Materials and Methods. Twenty-five patients with advanced non-small cell lung cancer underwent chest MR imaging including DWI before and at the end of the first cycle of chemotherapy. The tumor’s mean ADC value and diameters on MR images were calculated and compared. The grouping reference was based on serial CT scans according to Response Evaluation Criteria in Solid Tumors. Logistic regression was applied to assess treatment response prediction ability of ADC value and diameters. Results. The change of ADC value in partial response group was higher than that in stable disease group (P=0.004. ROC curve showed that ADC value could predict treatment response with 100% sensitivity, 64.71% specificity, 57.14% positive predictive value, 100% negative predictive value, and 82.7% accuracy. The area under the curve for combination of ADC value and longest diameter change was higher than any parameter alone (P≤0.01. Conclusions. The change of ADC value may be a sensitive indicator to predict early response to chemotherapy in lung cancer. Prediction ability could be improved by combining the change of ADC value and longest diameter.

  19. Detecting Acute Myocardial Infarction by Diffusion-Weighted versus T2-Weighted Imaging and Myocardial Necrosis Markers.

    Science.gov (United States)

    Jin, Jiyang; Chen, Min; Li, Yongjun; Wang, YaLing; Zhang, Shijun; Wang, Zhen; Wang, Lin; Ju, Shenghong

    2016-10-01

    We used a porcine model of acute myocardial infarction to study the signal evolution of ischemic myocardium on diffusion-weighted magnetic resonance images (DWI). Eight Chinese miniature pigs underwent percutaneous left anterior descending or left circumflex coronary artery occlusion for 90 minutes followed by reperfusion, which induced acute myocardial infarction. We used DWI preprocedurally and hourly for 4 hours postprocedurally. We acquired turbo inversion recovery magnitude T2-weighted images (TIRM T2WI) and late gadolinium enhancement images from the DWI slices. We measured the serum myocardial necrosis markers myoglobin, creatine kinase-MB isoenzyme, and cardiac troponin I at the same time points as the magnetic resonance scanning. We used histochemical staining to confirm injury. All images were analyzed qualitatively. Contrast-to-noise ratio (the contrast between infarcted and healthy myocardium) and relative signal index were used in quantitative image analysis. We found that DWI identified myocardial signal abnormity early (acute myocardial infarction and identified the infarct-related high signal more often than did TIRM T2WI: 7 of 8 pigs (87.5%) versus 3 of 8 (37.5%) ( P =0.046). Quantitative image analysis yielded a significant difference in contrast-to-noise ratio and relative signal index between infarcted and normal myocardium on DWI. However, within 4 hours after infarction, the serologic myocardial injury markers were not significantly positive. We conclude that DWI can be used to detect myocardial signal abnormalities early after acute myocardial infarction-identifying the infarction earlier than TIRM T2WI and widely used clinical serologic biomarkers.

  20. PI-RADS version 2: quantitative analysis aids reliable interpretation of diffusion-weighted imaging for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon; Jung, Dae Chul; Oh, Young Taik [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Seoul (Korea, Republic of); Shin, Su-Jin [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Hanyang University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Cho, Nam Hoon [Yonsei University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Choi, Young Deuk; Rha, Koon Ho; Hong, Sung Joon [Yonsei University College of Medicine, Department of Urology, Seoul (Korea, Republic of)

    2017-07-15

    To determine whether apparent diffusion coefficient (ADC) ratio aids reliable interpretation of diffusion-weighted imaging (DWI) for prostate cancer (PCa). Seventy-six consecutive patients with PCa who underwent DWI and surgery were included. Based on pathologic tumour location, two readers independently performed DWI scoring according to the revised Prostate Imaging Reporting and Data System (PI-RADSv2). ADC ratios of benign to cancerous prostatic tissue were then measured independently and compared between cases showing concordant and discordant DWI scores ≥4. Area under the curve (AUC) and threshold of ADC ratio were analyzed for DWI scores ≥4. The rate of inter-reader disagreement for DWI score ≥4 was 11.8% (9/76). ADC ratios were higher in concordant vs. discordant DWI scores ≥4 (median, 1.7 vs. 1.1-1.2; p < 0.001). For DWI scores ≥4, the AUCs of ADC ratios were 0.970 for reader 1 and 0.959 for reader 2. In patients with an ADC ratio >1.3, the rate of inter-reader disagreement for DWI score ≥4 decreased to 5.9-6.0%. An ADC ratio >1.3 yielded 100% (reader 1, 54/54; reader 2, 51/51) positive predictive value for clinically significant cancer. ADC ratios may be useful for reliable interpretation of DWI score ≥4 in PI-RADSv2. (orig.)

  1. Diffusion-weighted imaging as a problem-solving tool in the evaluation of patients with acute strokelike syndromes.

    Science.gov (United States)

    Schaefer, P W

    2000-10-01

    This article addresses syndromes that clinically and/or radiologically resemble acute stroke. These syndromes generally fall into four categories. (1) Patients with acute neurological deficits with nonischemic lesions and no acute abnormality on diffusion-weighted images. These patients may have peripheral vertigo, migraines, seizures, dementia, functional disorders, amyloid angiopathy, or metabolic disorders. When these patients present, we can confidently predict that they are not undergoing infarction. (2) Patients with ischemic lesions with reversible clinical deficits. Nearly 50% of patients with transient ischemic attacks have lesions with restricted diffusion. Patients with transient global amnesia may have punctate lesions with restricted diffusion in the medial hippocampus, parahippocampal gyms, and corpus callosum. (3) Vasogenic edema syndromes that may mimic acute infarction clinically and on conventional imaging. These include eclampsia/hypertensive encephalopathy, other posterior leukoencephalopathies, human immunodeficiency virus encephalopathy, hyperperfusion syndrome following carotid endarterectomy, venous sinus thrombosis, acute demyelination, and neoplasm. These syndromes demonstrate elevated diffusion rather than the restricted diffusion associated with acute ischemic stroke. (4) Entities in which restricted diffusion may resemble acute infarction. These include pyogenic infections, herpes virus encephalitis, Creutzfeldt-Jakob disease, diffuse axonal injury, tumors with dense cell packing, and rare acute demyelinative lesions.

  2. Diffusion-weighted MR imaging of uterine leiomyomas following uterine artery embolization

    International Nuclear Information System (INIS)

    Sutter, Olivier; Shotar, Eimad; Guerrache, Youcef; Place, Vinciane; Oprea, Raluca; Le Dref, Olivier; Boudiaf, Mourad; Soyer, Philippe; Dohan, Anthony; Dautry, Raphael; Sirol, Marc; Ricbourg, Aude

    2016-01-01

    To test whether variations in apparent diffusion coefficient (ADC) values of uterine leiomyomas after uterine artery embolization (UAE) may correlate with outcome and assess the effects of UAE on leiomyomas and normal myometrium with magnetic resonance imaging (MRI). Data of 49 women who underwent pelvic MRI before and after UAE were retrospectively reviewed. Uterine and leiomyoma volumes, ADC values of leiomyomas, and normal myometrium were calculated before and after UAE. By comparison with baseline ADC values, a significant drop in leiomyoma ADC was found at 6-month post-UAE (1.096 x 10 -3 mm 2 /s vs. 0.712 x 10 -3 mm 2 /s, respectively; p < 0.0001), but not at 48-h post-UAE. Leiomyoma devascularization was complete in 40/49 women (82 %) at 48 h and in 37/49 women (76 %) at 6 months. Volume reduction and leiomyoma ADC values at 6 months correlated with the degree of devascularization. There was a significant drop in myometrium ADC after UAE. Perfusion defect of the myometrium was observed at 48 h in 14/49 women (28.5 %) in association with higher degrees of leiomyoma devascularization. Six months after UAE, drop in leiomyoma ADC values and volume reduction correlate with the degree of leiomyoma devascularization. UAE affects the myometrium as evidenced by a drop in ADC values and initial myometrial perfusion defect. (orig.)

  3. Diffusion-weighted MR imaging of uterine leiomyomas following uterine artery embolization

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, Olivier; Shotar, Eimad; Guerrache, Youcef; Place, Vinciane; Oprea, Raluca; Le Dref, Olivier; Boudiaf, Mourad [Hopital Lariboisiere, AP-HP, Department of Body and Interventional Imaging, Paris (France); Soyer, Philippe; Dohan, Anthony [Hopital Lariboisiere, AP-HP, Department of Body and Interventional Imaging, Paris (France); Universite Paris-Diderot, Sorbonne Paris Cite, Paris (France); UMR INSERM 965, Hopital Lariboisiere, Paris (France); Dautry, Raphael; Sirol, Marc [Hopital Lariboisiere, AP-HP, Department of Body and Interventional Imaging, Paris (France); Universite Paris-Diderot, Sorbonne Paris Cite, Paris (France); Ricbourg, Aude [Hopital Lariboisiere-AP-HP, Department of Obstetrics and Gynecology, Paris (France)

    2016-10-15

    To test whether variations in apparent diffusion coefficient (ADC) values of uterine leiomyomas after uterine artery embolization (UAE) may correlate with outcome and assess the effects of UAE on leiomyomas and normal myometrium with magnetic resonance imaging (MRI). Data of 49 women who underwent pelvic MRI before and after UAE were retrospectively reviewed. Uterine and leiomyoma volumes, ADC values of leiomyomas, and normal myometrium were calculated before and after UAE. By comparison with baseline ADC values, a significant drop in leiomyoma ADC was found at 6-month post-UAE (1.096 x 10{sup -3} mm{sup 2}/s vs. 0.712 x 10{sup -3} mm{sup 2}/s, respectively; p < 0.0001), but not at 48-h post-UAE. Leiomyoma devascularization was complete in 40/49 women (82 %) at 48 h and in 37/49 women (76 %) at 6 months. Volume reduction and leiomyoma ADC values at 6 months correlated with the degree of devascularization. There was a significant drop in myometrium ADC after UAE. Perfusion defect of the myometrium was observed at 48 h in 14/49 women (28.5 %) in association with higher degrees of leiomyoma devascularization. Six months after UAE, drop in leiomyoma ADC values and volume reduction correlate with the degree of leiomyoma devascularization. UAE affects the myometrium as evidenced by a drop in ADC values and initial myometrial perfusion defect. (orig.)

  4. The comparative study of MR diffusion-weighted imaging and MR perfusion-weighted imaging in diagnosing soft tissue tumors

    International Nuclear Information System (INIS)

    Wang Shaowu; Zhang Li'na; Sun Meiyu; Song Qingwei; Jia Feige

    2009-01-01

    Objective: To evaluate MR diffusion-weighted imaging (DWI)and MR perfusion- weighted imaging(PWI) in differentiating benign from malignant soft tissue tumors by comparing the related parameters. Methods: Fifty patients with soft tissue tumors verified by pathology (benign 24, malignant 26) underwent DWI and dynamic contrast-enhanced T 2 * -weighted PWI. DWI and PWI data of benign and malignant soft tissue tumors were acquired at the workstation and their difference was analyzed with t-test. The diagnostic accordance rate was verified with x 2 -test. Subjective overall performance of two techniques were evaluated with receiver operating characteristic (ROC) analysis. Results: ADC values of benign and malignant tumors were (2.03±0.36) x 10 -3 mm 2 /s, (1.52±0.39) x 10 -3 mm 2 /s, respectively. The signal intensity decrease of them during the first-pass perfusion (SI decrease ) were (13.54 ± 3.37)%, (47.57 ± 5.21)%, respectively. The maximum linearity slope rate of TIC (SS max ) of them were (5.51 ± 2.54)%, (7.94 ± 3.33)%, respectively. There were significant differences between benign and malignant tumors of ADC value and SI decrease (t=2.515, 2.938; P max (t= 1.272,P>0.05). When the threshold of ADC value was 1.866 x mm 2 /s, sensitivity and specificity for determining malignant tumors were 84.6% (22/26)and 83.3% (20/24). When the threshold of SI decrease was 40.33%, sensitivity and specificity for determining malignant tumors were 88.5% (23/26)and 75.0% (18/24). In type la of TIC, the proportion of benign soft tissue tumor was 3/24 and malignant tumor was 20/26. In type Ib, benign tumor was 14/24 and malignant tumor was 3/26. In type Ic, malignant tumor was 3/26. In type II, benign tumor was 7/24. The diagnostic accordance rate of DWI and PWI were 84.0% (42/50)and 82.0% (41/50), respectively. There was no significant difference between them (χ 2 =0.8, P>0.05). The accuracies of them were 81.7%, 83.6% respectively by the area under the ROC curve (AUC). The

  5. Diffusion-weighted imaging and magnetic resonance proton spectroscopy following preterm birth

    International Nuclear Information System (INIS)

    Hart, A.R.; Smith, M.F.; Whitby, E.H.; Alladi, S.; Wilkinson, S.; Paley, M.N.; Griffiths, P.D.

    2014-01-01

    Aim: To study the associations between magnetic resonance proton spectroscopy (MRS) data and apparent diffusion coefficients (ADC) from the preterm brain with developmental outcome at 18 months corrected age and clinical variables. Materials and methods: A prospective observational cohort study of 67 infants born before 35 weeks gestational age who received both magnetic resonance imaging of the brain between 37 and 44 weeks corrected gestational age and developmental assessment around 18 months corrected age. Results: No relationships were found between ADC values and MRS results or outcome. MRS ratios involving N-acetyl aspartate (NAA) from the posterior white matter were associated with ''severe'' and ''moderate to severe'' difficulties, and fine motor scores were significantly lower in participants with a visible lactate doublet in the posterior white matter. The presence of a patent ductus arteriosus (PDA) was the only clinical factor related to NAA ratios. Conclusion: Altered NAA levels in the posterior white matter may reflect subtle white matter injury associated with neuro-developmental difficulties, which may be related to a PDA. Further work is needed to assess the longer-term neuro-developmental implications of these findings, and to study the effect of PDAs on developmental outcome in later childhood/adolescence. - Highlights: • ADC values around term corrected age from a wide area of the brain are not associated with developmental outcome. • NAA ratios from the posterior white matter are associated with adverse outcome. • No relationship between MRS data and ADC values exist when measured from the same region of the cerebral white matter. • The presence of a patent ductus arterious was associated with NAA ratios from the posterior white matter, but not outcome

  6. Extracranial Soft-Tissue Tumors: Repeatability of Apparent Diffusion Coefficient Estimates from Diffusion-weighted MR Imaging.

    Science.gov (United States)

    Winfield, Jessica M; Tunariu, Nina; Rata, Mihaela; Miyazaki, Keiko; Jerome, Neil P; Germuska, Michael; Blackledge, Matthew D; Collins, David J; de Bono, Johann S; Yap, Timothy A; deSouza, Nandita M; Doran, Simon J; Koh, Dow-Mu; Leach, Martin O; Messiou, Christina; Orton, Matthew R

    2017-07-01

    Purpose To assess the repeatability of apparent diffusion coefficient (ADC) estimates in extracranial soft-tissue diffusion-weighted magnetic resonance imaging across a wide range of imaging protocols and patient populations. Materials and Methods Nine prospective patient studies and one prospective volunteer study, performed between 2006 and 2016 with research ethics committee approval and written informed consent from each subject, were included in this single-institution study. A total of 141 tumors and healthy organs were imaged twice (interval between repeated examinations, 45 minutes to 10 days, depending the on study) to assess the repeatability of median and mean ADC estimates. The Levene test was used to determine whether ADC repeatability differed between studies. The Pearson linear correlation coefficient was used to assess correlation between coefficient of variation (CoV) and the year the study started, study size, and volumes of tumors and healthy organs. The repeatability of ADC estimates from small, medium, and large tumors and healthy organs was assessed irrespective of study, and the Levene test was used to determine whether ADC repeatability differed between these groups. Results CoV aggregated across all studies was 4.1% (range for each study, 1.7%-6.5%). No correlation was observed between CoV and the year the study started or study size. CoV was weakly correlated with volume (r = -0.5, P = .1). Repeatability was significantly different between small, medium, and large tumors (P < .05), with the lowest CoV (2.6%) for large tumors. There was a significant difference in repeatability between studies-a difference that did not persist after the study with the largest tumors was excluded. Conclusion ADC is a robust imaging metric with excellent repeatability in extracranial soft tissues across a wide range of tumor sites, sizes, patient populations, and imaging protocol variations. Online supplemental material is available for this article.

  7. Initial experience with identifying high-grade prostate cancer using diffusion-weighted MR imaging (DWI) in patients with a Gleason score

    NARCIS (Netherlands)

    Somford, D.M.; Hambrock, T.; Hulsbergen-van de Kaa, C.A.; Futterer, J.J.; Oort, I.M. van; Basten, J.P. van; Karthaus, H.F.M.; Witjes, J.A.; Barentsz, J.O.

    2012-01-01

    INTRODUCTION: Diffusion-weighted magnetic resonance (MR) imaging (DWI) might be able to fulfill the need to accurately identify high-grade prostate carcinoma, in patients initially selected for active surveillance in the Prostate Specific Antigen (PSA) screening era based on transrectal

  8. Utility of Diffusion Weighted Magnetic Resonance Imaging with Multiple B Values in Evaluation of Pancreatic Malignant and Benign Lesions and Pancreatitis.

    Science.gov (United States)

    Karadeli, Elif; Erbay, Gurcan; Parlakgumus, Alper; Koc, Zafer

    2018-02-01

    To determine the feasibility of diffusion-weighted imaging in evaluation of pancreatic lesions and in differentiation of benign from malignant lesions. Descriptive study. Baskent University Adana Teaching and Research Center, Adana, Turkey, between September 2013 and May 2015. Forty-three lesions [pancreas adenocarcinoma (n=25)], pancreatitis (n=10), benign lesion (n=8)] were utilized with diffusion-weighted magnetic resonance imaging with multiple b-values. Different ADC maps of diffusion weighted images by using b-values were acquired. The median ADC at all b values for malignant lesions was significantly different from that for benign lesions (pvalues were compared between benign lesions/normal parenchyma and malignant lesions/normal parenchyma, there was a significant statistical difference in all b values between benign and malignant lesions except at b 50 and b 200 (pvalue (AUC=0.804) was more effective than the lesion ADC for b 600 value (AUC=0.766) in differentiation of benign and malignant lesions. The specificity and sensitivity of the lesion/normal parenchyma ADC ratio were higher than those of ADC values of lesions. When the ADC was compared between benign lesions and pancreatitis, a significant difference was found at all b values (pvalue combinations (p>0.05). Diffusion-weighted magnetic resonance images can be helpful in differentiation of pancreatic carcinoma and benign lesions. Lesion ADC / normal parenchyma ADC ratios are more important than lesion ADC values in assessment of pancreatic lesions.

  9. Acute necrotizing encephalopathy secondary to diphtheria, tetanus toxoid and whole-cell pertussis vaccination: diffusion-weighted imaging and proton MR spectroscopy findings

    International Nuclear Information System (INIS)

    Aydin, Hale; Ozgul, Esra; Agildere, Ahmet Muhtesem

    2010-01-01

    We present a previously healthy 6-month-old boy who was admitted to our hospital with lethargy, hypotonia and focal clonic seizures 6 days following diptheria, tetanus toxoid and whole-cell pertussis vaccination. A diagnosis of acute necrotising encephalopathy was made with the aid of MRI, including diffusion-weighted imaging and proton MR spectroscopy. (orig.)

  10. Acute necrotizing encephalopathy secondary to diphtheria, tetanus toxoid and whole-cell pertussis vaccination: diffusion-weighted imaging and proton MR spectroscopy findings

    Energy Technology Data Exchange (ETDEWEB)

    Aydin, Hale; Ozgul, Esra; Agildere, Ahmet Muhtesem [Baskent University Hospital, Department of Radiology, Ankara (Turkey)

    2010-07-15

    We present a previously healthy 6-month-old boy who was admitted to our hospital with lethargy, hypotonia and focal clonic seizures 6 days following diptheria, tetanus toxoid and whole-cell pertussis vaccination. A diagnosis of acute necrotising encephalopathy was made with the aid of MRI, including diffusion-weighted imaging and proton MR spectroscopy. (orig.)

  11. Intravoxel incoherent motion diffusion-weighted imaging in stroke patients: initial clinical experience

    International Nuclear Information System (INIS)

    Yao, Y.; Zhang, S.; Tang, X.; Zhang, S.; Shi, J.; Zhu, W.; Zhu, W.

    2016-01-01

    Aim: To evaluate the feasibility of using intravoxel incoherent motion (IVIM) to measure diffusion and perfusion parameter variations in stroke. Materials and methods: Thirty-eight stroke patients were enrolled in the study. IVIM imaging was performed using 15 b-values from 0 to 1000 s/mm 2 . Arterial spin labelling (ASL) magnetic resonance perfusion was also undertaken. Relations between the IVIM parameters (including apparent diffusion coefficient [ADC], diffusion coefficient D slow [D], pseudo-diffusion coefficient D fast [D*], fractional perfusion-related volume [f]) and fD* (the multiplication of the first two parameters) and the ASL-derived parameter, cerebral blood flow (CBF), were analysed using paired t-tests. Comparisons of all the parameters between lesions and contralateral normal regions, as well as between acute and subacute groups were analysed using Student's t-test. Results: There were positive correlations between f and CBF as well as fD* and CBF (r=0.472 and 0.653). Quantitative analysis showed a significant decrease in ADC, D, D*, f, fD*, and CBF of the lesions compared with the contralateral side, in which the decrease of fD* (68.6%) was highest. The values of ADC, f, and fD* increased in the subacute period group compared with the acute period group. Conclusions: IVIM analysis allowed separation of perfusion contribution from true diffusion and thus provided an evaluation of the perfusion and diffusion variations during stroke, which might further elucidate the mechanisms of ischaemic stroke. - Highlights: • There exist positive correlations between fractional perfusion-related volume (f) and cerebral blood flow (CBF) as well as fD ∗ and CBF. • A significant decrease in ADC, diffusion coefficient D slow (D), pseudo-diffusion coefficient D fast (D ∗ ), f, fD ∗ and CBF of the lesions compared with the contralateral normal regions. • The values of ADC, f and fD ∗ increase significantly in the subacute period compared with the

  12. Diffusion-weighted MR imaging of the pancreas: optimizing b-value for visualization of pancreatic adenocarcinoma

    International Nuclear Information System (INIS)

    Fukukura, Yoshihiko; Shindo, Toshikazu; Hakamada, Hiroto; Takumi, Koji; Umanodan, Tomokazu; Nakajo, Masanori; Kamimura, Kiyoshisa; Umanodan, Aya; Ideue, Junnichi; Yoshiura, Takashi

    2016-01-01

    To determine the optimal b-value of 3.0-T diffusion-weighted imaging (DWI) for visualizing pancreatic adenocarcinomas Fifty-five patients with histologically confirmed pancreatic adenocarcinoma underwent DWI with different b-values (b = 500, 1000, 1500, and 2000 s/mm 2 ) at 3.0 T. For each b-value, we retrospectively evaluated DWI findings of pancreatic adenocarcinomas (clear hyperintensity relative to the surrounding pancreas, hyperintensity with an unclear distal border, and isointensity) and image quality, and measured tumour-to-pancreas signal intensity (SI) ratios. DWI findings, image quality, and tumour-to-pancreas SI ratios were compared between the four b-values. There was a significantly higher incidence of tumours showing clear hyperintensity on DWI with b-value of 1500 s/mm 2 than on that with b-value of 1000 s/mm 2 (P < 0.001), and on DWI with b-value of 1000 s/mm 2 than on that with b-value of 500 s/mm 2 (P < 0.001). The tumour-to-distal pancreas SI ratio was higher with b-value of 1500 s/mm 2 than with b-value of 1000 s/mm 2 (P < 0.001), and with b-value of 1000 s/mm 2 than with b-value of 500 s/mm 2 (P < 0.001). A lower image quality was obtained at increasing b-values (P < 0.001); the lowest scores were observed with b-value of 2000 s/mm 2 . The use of b = 1500 s/mm 2 for 3.0-T DWI can improve the delineation of pancreatic adenocarcinomas. (orig.)

  13. Diffusion-weighted MR imaging of the pancreas: optimizing b-value for visualization of pancreatic adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko; Shindo, Toshikazu; Hakamada, Hiroto; Takumi, Koji; Umanodan, Tomokazu; Nakajo, Masanori; Kamimura, Kiyoshisa; Umanodan, Aya; Ideue, Junnichi; Yoshiura, Takashi [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Radiology, Kagoshima City (Japan)

    2016-10-15

    To determine the optimal b-value of 3.0-T diffusion-weighted imaging (DWI) for visualizing pancreatic adenocarcinomas Fifty-five patients with histologically confirmed pancreatic adenocarcinoma underwent DWI with different b-values (b = 500, 1000, 1500, and 2000 s/mm{sup 2}) at 3.0 T. For each b-value, we retrospectively evaluated DWI findings of pancreatic adenocarcinomas (clear hyperintensity relative to the surrounding pancreas, hyperintensity with an unclear distal border, and isointensity) and image quality, and measured tumour-to-pancreas signal intensity (SI) ratios. DWI findings, image quality, and tumour-to-pancreas SI ratios were compared between the four b-values. There was a significantly higher incidence of tumours showing clear hyperintensity on DWI with b-value of 1500 s/mm{sup 2} than on that with b-value of 1000 s/mm{sup 2} (P < 0.001), and on DWI with b-value of 1000 s/mm{sup 2} than on that with b-value of 500 s/mm{sup 2} (P < 0.001). The tumour-to-distal pancreas SI ratio was higher with b-value of 1500 s/mm{sup 2} than with b-value of 1000 s/mm{sup 2} (P < 0.001), and with b-value of 1000 s/mm{sup 2} than with b-value of 500 s/mm{sup 2} (P < 0.001). A lower image quality was obtained at increasing b-values (P < 0.001); the lowest scores were observed with b-value of 2000 s/mm{sup 2}. The use of b = 1500 s/mm{sup 2} for 3.0-T DWI can improve the delineation of pancreatic adenocarcinomas. (orig.)

  14. Diffusion-weighted magnetic resonance imaging for prediction of insignificant prostate cancer in potential candidates for active surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Heon; Jeong, Jae Yong; Lee, Sin Woo; Sung, Hyun Hwan; Jeon, Hwang Gyun; Jeong, Byong Chang; Seo, Seong Il; Lee, Hyun Moo; Choi, Han Yong; Jeon, Seong Soo [Sungkyunkwan University School of Medicine, Department of Urology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-06-01

    To investigate whether the apparent diffusion coefficient (ADC) from diffusion-weighted magnetic resonance imaging (DW-MRI) could help improve the prediction of insignificant prostate cancer in candidates for active surveillance (AS). Enrolled in this retrospective study were 287 AS candidates who underwent DW-MRI before radical prostatectomy. Patients were stratified into two groups; Group A consisted of patients with no visible tumour or a suspected tumour ADC value > 0.830 x 10{sup -3} mm{sup 2}/sec and Group B consisted of patients with a suspected tumour ADC value < 0.830 x 10{sup -3} mm{sup 2}/sec. We compared pathological outcomes in each group. Group A had 243 (84.7 %) patients and Group B had 44 (15.3 %) patients. The proportion of organ-confined Gleason ≤ 6 disease and insignificant prostate cancer was significantly higher in Group A than Group B (61.3 % vs. 38.6 %, p = 0.005 and 47.7 % vs. 25.0 %, p = 0.005, respectively). On multivariate analysis, a high ADC value was the independent predictor of organ-confined Gleason ≤ 6 disease and insignificant prostate cancer (odds ratio = 2.43, p = 0.011 and odds ratio = 2.74, p = 0.009, respectively). Tumour ADC values may be a useful marker for predicting insignificant prostate cancer in candidates for AS. (orig.)

  15. Value of diffusion-weighted imaging in predicting parametrial invasion in stage IA2-IIA cervical cancer

    International Nuclear Information System (INIS)

    Park, Jung Jae; Kim, Chan Kyo; Park, Sung Yoon; Park, Byung Kwan; Kim, Bohyun

    2014-01-01

    To investigate the value of diffusion-weighted imaging (DWI) in evaluating parametrial invasion (PMI) in stage IA2-IIA cervical cancer. A total of 117 patients with stage IA2-IIA cervical cancer who underwent preoperative MRI and radical hysterectomy were included in this study. Preoperative clinical variables and MRI variables were analysed and compared between the groups with and without pathologically proven PMI. All variables except age were significantly different between patients with and without pathologic PMI (P < 0.05). All variables except squamous cell carcinoma (SCC) antigen were also significantly correlated with pathologic PMI on univariate analysis (P < 0.05). Multivariate analysis indicated that PMI on MRI (P < 0.001) and tumour apparent diffusion coefficient (ADC) (P = 0.029) were independent predictors of pathologic PMI. Area under the curve of PMI on MRI increased significantly from 0.793 to 0.872 when combined with tumour ADC (P = 0.002). When PMI on MRI was further stratified by tumour ADC, the false negative rate was 2.0 % (1/49). In stage IA2-IIA cervical cancer, tumour ADC and PMI on MRI seem to be independent predictors of pathologic PMI. Combining the two predictors improved the diagnostic performance of identifying patients at low risk of pathologic PMI. (orig.)

  16. Case report of a young stroke patient showing interim normalization of the MRI diffusion-weighted imaging lesion

    International Nuclear Information System (INIS)

    Ostwaldt, Ann-Christin; Usnich, Tatiana; Nolte, Christian H.; Villringer, Kersten; Fiebach, Jochen B.

    2015-01-01

    In acute ischemic stroke, diffusion weighted imaging (DWI) shows hyperintensities and is considered to indicate irreversibly damaged tissue. We present the case of a young stroke patient with unusual variability in the development of signal intensities within the same vessel territory. A 35-year-old patient presented with symptoms of global aphasia and hypesthesia of the left hand. MRI demonstrated a scattered lesion in the MCA territory. After rtPA therapy the patient received further MRI examination, three times on day 1, and once on day 2, 3, 5 and 43. The posterior part of the lesion showed the usual pattern with increasing DWI hyperintensity and decreased ADC, as well as delayed FLAIR positivity. However, the anterior part of the lesion, which was clearly visible in the first examination completely normalized on the first day and only reappeared on day 2. This was accompanied by a normalization of the ADC as well as an even further delayed FLAIR positivity. We showed that interim normalization of DWI and ADC in the acute phase can not only be found in rodent models of stroke, but also in humans. We propose that DWI lesion development might be more variable during the first 24 h after stroke than previously assumed

  17. Assessment of brain temperatures during different phases of the menstrual cycle using diffusion-weighted imaging thermometry.

    Science.gov (United States)

    Tsukamoto, Taro; Shimono, Taro; Sai, Asari; Sakai, Koji; Yamamoto, Akira; Sakamoto, Shinichi; Miki, Yukio

    2016-04-01

    To investigate changes in brain temperature according to the menstrual cycle in women using diffusion-weighted imaging (DWI) thermometry and to clarify relationships between brain and body temperatures. In 20 healthy female volunteers (21.3-38.8 years), DWI of the brain was performed during the follicular and luteal phases to calculate the brain temperature. During DWI, body temperatures were also measured. Group comparisons of each temperature between the two phases were performed using the paired t test. Correlations between brain and body temperatures were analyzed using Pearson's correlation coefficient test. Mean diffusion-based brain temperature was 36.24 °C (follicular) and 36.96 °C (luteal), showing a significant difference (P < 0.0001). Significant differences were also seen for each body temperature between the two phases. Correlation coefficients between diffusion-based brain and each body temperature were r = 0.2441 (P = 0.1291), -0.0332 (0.8387), and -0.0462 (0.7769), respectively. In women of childbearing age, brain and body temperatures appear significantly higher in the luteal than in the follicular phase. However, brain and body temperatures show no significant correlations.

  18. Investigation of a phantom for diffusion weighted imaging that controlled the apparent diffusion coefficient using gelatin and sucrose

    International Nuclear Information System (INIS)

    Tamura, Takayuki; Usui, Shuji; Akiyama, Mitoshi

    2009-01-01

    When studying diffusion weighted imaging (DWI), it is important to create a phantom that has a reliably controlled diffusion coefficient. In this study, we investigated phantoms to control both the diffusion coefficient and the T2-value by changing the concentration of gelatin or sucrose and MnCl 2 , respectively. The results showed that the diffusion coefficient decreased linearly with increases in the gelatin or sucrose concentration, and decreasing of their relaxation times was observed. By properly adjusting the MnCl 2 concentrations, we were able to equalize the T2-values between phantoms having different gelatin or sucrose concentrations. Temperature dependence of the diffusion coefficient was also revealed. This phantom can be made stable for a few months by adding a small amount of NaN 3 as an antiseptic agent, has a diffusion coefficient similar to that of neural tissue or clinical tumor, and is able to control the T2-value properly. We consider this phantom suitable for studying SE-type DWI and contributes to elucidation of this technique. (author)

  19. DSA-guided embolization in establishing different canine spinal cord ischemia models and relevant diffusion-weighted imaging study

    International Nuclear Information System (INIS)

    Zhang Jingsong; Sun Lijun; Huan Yi; He Hongde; Zhang Xuexin; Zhao Haitao; Zhang Jing; Zhang Xijing

    2006-01-01

    Objective: To evaluate DSA-guided embolization in establishing different spinal cord ischemia models of canine and relevant diffusion-weighted imaging (DWI) application. Methods: Nine canines were randomly divided into three groups with different matching of lipiodol and diatrizoate meglumine which were injected into bilateral intercostal arteries at 9-11 level guided by DSA monitor. Then observe the changes of motor function and pathologic findings, especially perform routine MRI and DWI by a 1.5 T MR system. Results: Except one case, 8 embolization models were established successfully. Among three groups, slight-group got slight injury and muscle power was about 3-5 grade and range of injury was about two vertebra distance; medium-group presented obvious paraplegia and muscle power was 0-1 grade and range of injury was between 3-4 vertebra distance; severe-group showed greater severity and larger range of injury. All lesions presented high signals at routine MRI and DWI. Conclusion: Using different matching of lipiodol and diatrizoate meglumine can establish different spinal cord ischemia models of canine by DSA- guided embolization and DWI can be performed successfully by 1.5 T MR system, which may be a good method for advanced study of spinal cord ischemia. (authors)

  20. Diffusion weighted imaging best discriminates PD from MSA-P: A comparison with tilt table testing and heart MIBG scintigraphy.

    Science.gov (United States)

    Köllensperger, Martin; Seppi, Klaus; Liener, Claudia; Boesch, Sylvia; Heute, Dirk; Mair, Katherina J; Mueller, Joerg; Sawires, Martin; Scherfler, Christoph; Schocke, Michael F; Donnemilier, Eveline; Virgolini, Irene; Wenning, Gregor K; Poewe, Werner

    2007-09-15

    Both diffusion weighted magnetic resonance imaging (DWI) of the basal ganglia and meta-iodobenzylguanidin (MIBG) scintigraphy of the heart have been reported useful in the differential diagnosis of patients with Parkinson's disease (PD) vs. the parkinson variant of multiple system atrophy (MSA-P). Their diagnostic value, however, has never been directly compared in patients with parkinsonism and autonomic dysfunction. We have studied 9 patients with PD and 9 patients with MSA-P matched for age and disease severity. Regional trace of the diffusion tensor values were determined in the putamina. Cardiac MIBG uptake was quantified by comparing regions of interest over heart and mediastinum Heart/Mediastinum (H/M) ratio. Furthermore, all patients underwent tilt testing. PD patients showed significantly lower H/M ratios than normal controls; however, there was considerable overlap between the two patient groups. We did not detect any significant differences of blood pressure response to passive tilt between the two patient groups. Sensitivity of MIBG scintigraphy versus DWI for the differentiation of MSA-P from PD was 55.6% vs. 100%, specificity 88.8% vs. 100%, and area under the curve 0.802 vs. 1.000. Our data suggest that DWI is superior to both tilt table testing and MIBG scintigraphy in the differential diagnosis of PD versus MSA-P. (c) 2007 Movement Disorder Society.

  1. Diffusion-weighted and dynamic contrast-enhanced imaging as markers of clinical behavior in children with optic pathway glioma

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Sarah C. [Swedish Neuroscience Institute, Department of Neurosurgery, Seattle, WA (United States); Ackerman, Joseph W. [Washington University School of Medicine, Department of Radiology, 660 South Euclid Ave., Box 8131, St. Louis, MO (United States); Garbow, Joel R. [Washington University School of Medicine, Department of Radiology, 660 South Euclid Ave., Box 8131, St. Louis, MO (United States); Alvin J. Siteman Cancer Center, St. Louis, MO (United States); Manwaring, Linda P. [Washington University School of Medicine, Department of Pediatrics, St. Louis, MO (United States); Washington University School of Medicine, Department of Genetics and Genomic Medicine, St. Louis, MO (United States); Gutmann, David H. [Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States); Alvin J. Siteman Cancer Center, St. Louis, MO (United States); McKinstry, Robert C. [Washington University School of Medicine, Department of Radiology, 660 South Euclid Ave., Box 8131, St. Louis, MO (United States); Washington University School of Medicine, Department of Pediatrics, St. Louis, MO (United States)

    2008-12-15

    Optic pathway gliomas (OPGs) are common pediatric brain tumors that pose significant clinical challenges with regard to predicting which tumors are likely to become symptomatic and require treatment. These tumors can arise sporadically or in the context of the inherited cancer predisposition syndrome neurofibromatosis type 1 (NF1). Few studies have suggested biological or imaging markers that predict the clinical course of this disease. In this cross-sectional study, we hypothesized that the clinical behavior of OPGs in children can be differentiated by diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI. A total of 27 children with OPG were studied using DW and DCE MRI protocols. Diffusivity and permeability were calculated and correlated with the clinical behavior the OPG. Mean diffusivity values of 1.39 {mu}m{sup 2}/ms and mean permeability values of 2.10 ml/min per 100 cm{sup 3} of tissue were measured. Clinically aggressive OPGs had significantly higher mean permeability values (P = 0.05) than clinically stable tumors. In addition, there was a strong correlation between clinical aggressiveness and the absence of NF1 (P < 0.01). These results suggest that DCE MRI might be a useful biomarker for clinically aggressive OPG, which should be confirmed in larger prospective longitudinal studies. (orig.)

  2. Apparent diffusion coefficient measurement by diffusion weighted magnetic resonance imaging is a useful tool in differentiating renal tumors.

    Science.gov (United States)

    Liu, Jing-Hong; Tian, Shi-Feng; Ju, Ye; Li, Ye; Chen, An-Liang; Chen, Li-Hua; Liu, Ai-Lian

    2015-04-16

    To determine the clinical value of apparent diffusion coefficient (ADC) measurement by diffusion weighted magnetic resonance imaging (DW-MRI) in differentiating renal tumors. Electronic databases were searched using combinations of keywords and free words relating to renal tumor, ADC and DW-MRI. Based on carefully selected inclusion and exclusion criteria, relevant case-control studies were identified and the related clinical data was acquired. Statistical analyses were performed using STATA 12.0 (Stata Corporation, College station, TX). Sixteen case-control studies were ultimately included in the present meta-analysis. These 16 high quality studies contained a combined total of 438 normal renal tissues and 832 renal tumor lesions (597 malignant and 235 benign). The results revealed that ADC values of malignant renal tumor tissues were markedly lower than normal renal tissues and benign renal tumor tissues. ADC values of benign renal tumor tissues were also significantly lower than normal renal tissue. ADC measurement by DW-MRI provided clinically useful information on the internal structure of renal tumors and could be an important radiographic index for differentiation of malignant renal tumors from benign renal tumors.

  3. Super-resolution reconstruction to increase the spatial resolution of diffusion weighted images from orthogonal anisotropic acquisitions

    Science.gov (United States)

    Scherrer, Benoit; Gholipour, Ali; Warfield, Simon K.

    2012-01-01

    Diffusion-weighted imaging (DWI) enables non-invasive investigation and characterization of the white matter but suffers from a relatively poor spatial resolution. Increasing the spatial resolution in DWI is challenging with a single-shot EPI acquisition due to the decreased signal-to-noise ratio and T2* relaxation effect amplified with increased echo time. In this work we propose a super-resolution reconstruction (SRR) technique based on the acquisition of multiple anisotropic orthogonal DWI scans. DWI scans acquired in different planes are not typically closely aligned due to the geometric distortion introduced by magnetic susceptibility differences in each phase-encoding direction. We compensate each scan for geometric distortion by acquisition of a dual echo gradient echo field map, providing an estimate of the field inhomogeneity. We address the problem of patient motion by aligning the volumes in both space and q-space. The SRR is formulated as a maximum a posteriori problem. It relies on a volume acquisition model which describes how the acquired scans are observations of an unknown high-resolution image which we aim to recover. Our model enables the introduction of image priors that exploit spatial homogeneity and enables regularized solutions. We detail our SRR optimization procedure and report experiments including numerical simulations, synthetic SRR and real world SRR. In particular, we demonstrate that combining distortion compensation and SRR provides better results than acquisition of a single isotropic scan for the same acquisition duration time. Importantly, SRR enables DWI with resolution beyond the scanner hardware limitations. This work provides the first evidence that SRR, which employs conventional single shot EPI techniques, enables resolution enhancement in DWI, and may dramatically impact the role of DWI in both neuroscience and clinical applications. PMID:22770597

  4. Modern MRI tools for the characterization of acute demyelinating lesions: value of chemical shift and diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kueker, W.; Mehnert, F.; Mader, I.; Naegele, T. [Department of Neuroradiology, University of Tuebingen Medical School, Hoppe-Seyler-Str. 3, 72076, Tuebingen (Germany); Ruff, J. [Siemens Medical Solutions, Erlangen (Germany); Gaertner, S. [Department of Neurology, University of Tuebingen Medical School, Tuebingen (Germany)

    2004-06-01

    Acute demyelinating lesions occur in various inflammatory disorders of the CNS. Apart from multiple sclerosis, most cases can be attributed to an overshooting immunological response to infectious agents called acute disseminated encephalomyelitis (ADEM). ADEM, which is mostly characterized by a monophasic course, has a multiphasic variant (MDEM). The early application of corticosteroids has been shown to be beneficial for the outcome; thus, an early diagnosis is highly desirable. Furthermore, the differential diagnosis ruling out neoplastic disorders may be difficult using conventional MRI alone. The potential diagnostic value of advanced MR techniques such as chemical shift imaging (CSI) and diffusion-weighted imaging (DWI) was investigated in a patient with MDEM, who had a new lesion in continuity with the initial disease manifestation. CSI was performed at 1.5 T with a long echo time of 135 ms for the evaluation of N-acetyl-aspartate (NAA) and choline (Cho) and with short TE of 30 ms for macromolecules (mm) and myo-Inositol (mI). DWI was performed using a single-shot isotropic EPI sequence. Whereas acute and chronic areas of demyelination were neither distinguishable on T2- nor on contrast-enhanced T1-weigted images, CSI and DWI revealed different metabolite concentrations and diffusion characteristics within the composite lesion, clearly separating acute from chronic areas of demyelination. In conclusion, the addition of CSI and DWI may add to the diagnostic power of MRI in the setting of demyelinating disorders by identifying areas of acute and chronic demyelination, even in the absence of contrast enhancement. (orig.)

  5. Role of PROPELLER diffusion weighted imaging and apparent diffusion coefficient in the diagnosis of sellar and parasellar lesions

    International Nuclear Information System (INIS)

    Mahmoud, Omar M.; Tominaga, Atsushi; Amatya, Vishwa Jeet; Ohtaki, Megu; Sugiyama, Kazuhiko; Saito, Taiichi; Sakoguchi, Tetsuhiko; Kinoshita, Yasuyuki; Shrestha, Prabin; Abe, Nobukazu

    2010-01-01

    Objective: To evaluate the role of the apparent diffusion coefficient (ADC) using periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion weighted imaging (DWI) in the differentiation between sellar and parasellar mass lesions. Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 60 patients with sellar and parasellar lesions who had undergone PROPELLER DWI on a 3-T MR imager. Conventional MRI findings were expressed as the ratio of signal intensity (SI) in the lesions to the normal white matter and the degree of contrast enhancement. ADC values were calculated as the minimum (ADC-MIN), mean (ADC-MEAN), and maximum (ADC-MAX). All patients underwent surgery and all specimens were examined histologically. Logistic discriminant analysis was performed by using the SI ratios on T1- and T2-weighted images (T1-WI, T2-WI), the degree of enhancement, and absolute ADC values as independent variables. Results: ADC-MIN of hemorrhagic pituitary adenomas was lower than of the other lesions with similar appearance on conventional MRI (non-hemorrhagic pituitary adenomas, craniopharyngiomas, Rathke's cleft cysts; accuracy 100%); the useful cut-off value was 0.700 x 10 -3 mm 2 /s. ADC-MAX of meningiomas was lower than of non-hemorrhagic pituitary adenomas (accuracy 90.3%; p < 0.01). ADC-MIN of craniopharyngiomas was lower than of Rathke's cleft cysts (accuracy 100%; p < 0.05). Conclusion: As PROPELLER DWI is less sensitive to susceptibility artifacts than single-shot echoplanar DWI, it is more useful in the examination of sellar and parasellar lesions. Calculation of the ADC values helps to differentiate between various sellar and parasellar lesions.