WorldWideScience

Sample records for ecg-gated myocardial perfusion

  1. Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    Science.gov (United States)

    Sharif, Behzad; Dharmakumar, Rohan; Arsanjani, Reza; Thomson, Louise; Bairey Merz, C Noel; Berman, Daniel S; Li, Debiao

    2014-12-01

    Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preliminary study is to evaluate whether, in the simple case of single-slice two-dimensional imaging, adequate myocardial contrast can be obtained for accurate visualization of hypoperfused territories in the setting of myocardial ischemia. A T1-weighted pulse sequence with continuous golden-angle radial sampling was developed for non-ECG-gated FPP imaging. A sliding-window scheme with no temporal acceleration was used to reconstruct 8 frames/s. Canines were imaged at 3T with and without coronary stenosis using the proposed scheme and a conventional magnetization-prepared ECG-gated FPP method. Our studies showed that the proposed non-ECG-gated method is capable of generating high-resolution (1.7 × 1.7 × 6 mm(3) ) artifact-free FPP images of a single slice at high heart rates (92 ± 21 beats/min), while matching the performance of conventional FPP imaging in terms of hypoperfused-to-normal myocardial contrast-to-noise ratio (proposed: 5.18 ± 0.70, conventional: 4.88 ± 0.43). Furthermore, the detected perfusion defect areas were consistent with the conventional FPP images. Non-ECG-gated FPP imaging using optimized continuous golden-angle radial acquisition achieves desirable image quality (i.e., adequate myocardial contrast, high spatial resolution, and minimal artifacts) in the setting of ischemia. © 2014 Wiley Periodicals, Inc.

  2. ECG-gated HYPR reconstruction for undersampled CT myocardial perfusion imaging

    Science.gov (United States)

    Speidel, Michael A.; Van Lysel, Michael S.; Reeder, Scott B.; Supanich, Mark; Nett, Brian E.; Zambelli, Joseph; Chang, Su Min; Hsieh, Jiang; Chen, Guang-Hong; Mistretta, Charles A.

    2007-03-01

    In this study we develop a novel ECG-gated method of HYPR (HighlY constrained backPRojection) CT reconstruction for low-dose myocardial perfusion imaging and present its first application in a porcine model. HYPR is a method of reconstructing time-resolved images from view-undersampled projection data. Scanning and reconstruction techniques were explored using x-ray projections from a 50 sec contrast-enhanced axial scan of a 47 kg swine on a 64-slice MDCT system. Scans were generated with view undersampling factors from 2 to 10. A HYPR reconstruction algorithm was developed in which a fully-sampled composite image is generated from views collected from multiple cardiac cycles within a diastolic window. A time frame image for a heartbeat was produced by modifying the composite with projections from the cycle of interest. Heart rate variations were handled by automatically selecting cardiac window size and number of cycles per composite within defined limits. Cardiac window size averaged 35% of the R-R interval for 2x undersampling and increased to 64% R-R using 10x undersampling. The selected window size and cycles per composite was sensitive to synchrony between heart rate, gantry rate, and the view undersampling pattern. Temporal dynamics and perfusion metrics measured in conventional short-scan (FBP) images were well-reproduced in the undersampled HYPR time series. Mean transit times determined from HYPR myocardial time-density curves agreed to within 8% with the FBP results. The results indicate potential for an order of magnitude reduction in dose requirement per image in cardiac perfusion CT via undersampled scanning and ECG-gated HYPR reconstruction.

  3. The impact of hypertension on diastolic left ventricular function, evaluated by quantitative ECG-gated myocardial perfusion SPECT

    Directory of Open Access Journals (Sweden)

    Mohamed H.M. Sayed

    2015-09-01

    Conclusions: Quantitative ECG-gated Tc-99m tetrofosmin SPECT reveals that hypertensive patients with preserved global LV systolic function may have significant changes in diastolic LV function. Gated myocardial perfusion SPECT reports are always lacking in these changes in diastolic function. We recommend inclusion of such changes in diastolic function in gated myocardial perfusion SPECT reports that can help in proper management of hypertensive patients.

  4. Prognostic significance of stress myocardial ECG-gated perfusion imaging in asymptomatic patients with diabetic chronic kidney disease on initiation of haemodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Mitsuru; Kondo, Chisato; Kobayashi, Hideki; Kusakabe, Kiyoko [Tokyo Women' s Medical University, School of Medicine, Department of Radiology, Shinjuku-ku, Tokyo (Japan); Babazono, Tetsuya [Tokyo Women' s Medical University, School of Medicine, Diabetes Centre, Shinjuku-ku, Tokyo (Japan); Nakajima, Takatomo [Tokyo Women' s Medical University, School of Medicine, Department of Cardiology, Shinjuku-ku, Tokyo (Japan)

    2009-08-15

    Diabetic patients with chronic kidney disease (CKD) frequently develop cardiac events within several years of the initiation of haemodialysis. The present study assesses the prognostic significance of stress myocardial ECG-gated perfusion imaging (MPI) in patients with diabetic CKD requiring haemodialysis. Fifty-five asymptomatic patients with diabetic stage V CKD and no history of heart disease scheduled to start haemodialysis were enrolled in this study (56{+-}11 years old; 49 with type 2 diabetes mellitus). All patients underwent {sup 201}Tl stress ECG-gated MPI 1 month before or after the initiation of haemodialysis to assess myocardial involvement. We evaluated SPECT images using 17-segment defect scores graded on a 5-point scale, summed stress score (SSS) and summed difference scores (SDS). The patients were followed up for at least 2 years (42{+-}15 months) to determine coronary intervention (CI) and heart failure (HF) as soft events and acute myocardial infarction (AMI) and all causes of deaths as hard events. The frequencies of myocardial ischaemia, resting perfusion defects, low ejection fraction and left ventricular (LV) dilatation were 24,20,29 and 49%, respectively. Ten events (18%) developed during the follow-up period including four CI, one HF, one AMI and four sudden deaths. Multivariate Cox analysis selected SDS (p=0.0011) and haemoglobin A{sub 1c} (HbA{sub 1c}) (p=0.0076) as independent prognostic indicators for all events. Myocardial ischaemia, in addition to glycaemic control, is a strong prognostic marker for asymptomatic patients with diabetic CKD who are scheduled to start haemodialysis. Stress MPI is highly recommended for the management and therapeutic stratification of such patients. (orig.)

  5. Assessment of automatic quantification of myocardial perfusion and left ventricular function derived from ECG gated myocardial SPECT with {sup 99m}Tc-tetrofosmin in ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Mitsunori; Habara, Hirokazu; Tatsuno, Hironari; Fukuda, Hiroshi; Hamada, Noriko; Kazatani, Yukio [Ehime Prefectural Central Hospital (Japan)

    1999-09-01

    Non-invasive assessment of ischemic heart disease (IHD) requires information of both myocardial perfusion and left ventricular (LV) function. Recently, automatic quantification of ECG-gated myocardial scintigraphy with {sup 99m}Tc-tetrofosmin (QGS) can provide both of them. QGS, coronary angiograms (CAG) and left venticulograms (LVG) were performed in 83 patients with severe IHD in same period. Significant stenosis of coronary artery in CAG were assessed by QGS. The sensitivity, specificity and accuracy of significant stenosis by QGS was excellent (85%, 93% and 88%). The LV end-distolic and end-systolic volumes (EDV and ESV), LV ejection fraction (EF) and regional LV wall motion determined by QGS were compared to LVG. There was a good correlation between the values obtained from QGS and LVG (EDV: r=0.86, ESV: r=0.94, EF: r=0.84, p<0.0001), but QGS tended to underestimate EDV and EF. High complete agreement of regional LV wall motion was gained with 427 (74.0%) out of total 581 segments. In conclusion, QGS data was considered to be useful for assessment of determine significant stenosis and LV function in severe IHD. (author)

  6. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Measurement of left ventricular chamber and myocardial volume in hypertrophic cardiomyopathy patients by ECG-gated myocardial perfusion SPECT. Application of a newly developed edge-detection algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Yoshihiro; Katafuchi, Tetsuro; Hirase, Yoshinori; Sagoh, Masayoshi; Oka, Hisashi [National Cardiovascular Center, Suita, Osaka (Japan); Mori, Hideaki [Siemens-Asahi Medical Technologies, Ltd., Tokyo (Japan); Murase, Kenya [Osaka Univ., Suita (Japan). Medical School

    2002-12-01

    Quantitative gated SPECT (QGS) software has been reported to demonstrate inaccurate edge detection in the left ventricular chamber in hypertrophic cardiomyopathy patients. In this study we developed a method to calculate left ventricular volume (LVV) and left myocardial volume (LMV) from gated SPECT data using a newly developed edge-detection algorithm, and we compared it with the QGS method of calculating LVV and LMV in a phantom study. Our method gave more accurate measurements LVV and LMV whereas the QGS method underestimated LMV. Compared with QGS LVV and LMV, our method yielded better results in the phantom study. (author)

  8. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  9. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Rui, E-mail: rui_wang1979@yahoo.cn [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Qin, E-mail: tel1367@gmail.com [Department of Emergency, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); He Yi, E-mail: heyi139@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lu Dongxu, E-mail: larry.hi@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2011-11-15

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 {+-} 9.57 HU vs. 72.63 {+-} 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 {+-} 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  10. Evaluation of regional wall motion in myocardial infarction using animation ECG gated cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Takahiko; Hyodo, Haruo; Hayashi, Terumi; Yamamoto, Hideo; Yagi, Shigeru

    1984-08-01

    Regional wall motion of the left ventricle was evaluated in 21 patients with myocardial infarction using an animation system of gated cardiac computed tomographic (CT) images (animation gated CCT). The results obtained were compared with data by two-dimensional echocardiography (2-DE). 1. Evaluation of the asynergic area by animation gated CCT and 2-DE: Animation gated CCT detected the following specific regions with asynergy established by 2-DE; 10/10 cases (100%) at the anterior wall of the left ventricle, 14/14 cases (100%) at the interventricular septum, and 9/11 cases (81.8%) at the infero-posterior wall. In addition, one false positive case and one negative case were observed at the lateral wall and the apex, respectively. Of 37 instances with asynergic areas established by 2-DE, 21 cases or 89.2% were detected by animation gated CCT; the sensitivity was 91.9%. 2. Evaluation of severity of asynergy by animation gated CCT and 2-DE: The degree of asynergy evaluated by both methods was compared with each other, and the agreement was as follows: 10/10 cases (100%) at the left-ventricular anterior wall, 13/13 cases (100%) at the interventricular septum, and 7/9 cases (77.8%) at the infero-posterior wall. 3. Evaluation of the asynergic area by nonanimation gated CCT and 2-DE: Nonanimation gated CCT detected asynergic areas ascertained by 2-DE at the following areas; 8/10 cases (80%) at the left-ventricular anterior wall, 12/14 cases (85.7%) at the interventricular septum, and 4/11 cases (36.4%) at the infero-posterior wall. The difference between animation and nonanimation gated CCT was statistically significant (p < 0.05). The severity of asynergy could not be evaluated by nonanimation gated CCT. (J.P.N.).

  11. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  12. Feasibility and diagnostic accuracy of Ecg-gated SPECT myocardial perfusion imaging by a two-hour protocol: The Myofast study;Faisabilite et precision diagnostique d'un protocole de scintigraphie myocardique synchronisee a l'ECG en deux heures: l'etude Myofast

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, V.; Costo, S.; Sabatier, R.; Grollier, G.; Bouvard, G.; Agostini, D. [CHU Cote-de-Nacre, Service de medecine nucleaire, 14 - Caen (France)

    2010-04-15

    Aim of the study: To assess the feasibility of early stress and rest myocardial perfusion and function study using a fast {sup 99m}Tc-tetrofosmin gated-SPECT protocol in patients with known coronary artery disease. Materials and methods: Forty-three patients (pts) (37 M, 6 F, mean age 63.8 +- 9.8 years) underwent a {sup 99m}Tc-Tetrofosmin gated-SPECT (Axis Picker-Philips) myocardial study and a coronary angiography (C.A.) within 3 months. Images were acquired (LEHR, eight bins, 40 sec per image) after injection of {sup 99m}Tc-tetrofosmin (200 to 380 MBq) early (15 min) post-stress (36 dipyridamole, two dobutamine and five ergo-metric stress), and at rest after {sup 99m}Tc-tetrofosmin reinjection (600 to 1150 MBq), in a total time not exceeding 2 hours. Processing was performed with Q.G.S. software using the 17-segment model. Pathological study was defined as a summed difference score (SDS) greater than or equal to 4 4, a fixed defect with summed rest score greater than or equal to 4 and/or L.V. dysfunction defined as myocardial stunning (variation between stress and rest L.V.E.F. greater than or equal to 4 5%), stress L.V.E.F. less than or equal to 45% or rest L.V.E.F. less than or equal to 40%. Results were compared with C.A., and stenosis greater than or equal to 4 50% was considered as significant. Results: For 100% the quality of SPECT imaging was good or excellent. For six patients gating was impossible because of arrhythmia. The overall sensitivity, specificity and accuracy were 95%, 50%, and 91%, respectively. The concordance between gated SPECT and C.A. was moderate (kappa = 0.45, S.E. = 0.15). Interestingly, early-gated acquisition permitted to underline left ventricular dysfunction in 11 cases (30%), of whom eight had poly vascular disease. Stunning was detected in six of 37 cases (16%), of whom six had poly vascular disease. Conclusion: A one-day two-hour {sup 99m}Tc-tetrofosmin gated-SPECT protocol to assess left ventricular perfusion and function is

  13. 3D perfusion mapping in the intact mouse heart after myocardial infarction using myocardial contrast echocardiography

    Science.gov (United States)

    Li, Yinbo; Yang, Zequan; French, Brent A.; Hossack, John A.

    2005-04-01

    An intact mouse model of surgically-induced myocardial infarction (MI) caused by permanent occlusion of the Left Anterior Descending (LAD) coronary artery was studied. Normal mice with no occlusion were also studied as controls. For each mouse, contrast enhanced ultrasound images of the heart were acquired in parallel cross-sections perpendicular to the sternum at millimeter increments. For accurate 3D reconstruction, ECG gating and a tri-axial adjustable micromanipulator were used for temporal and spatial registration. Ultrasound images at steady-state of blood refilling were color-coded in each slice to show relative perfusion. Myocardial perfusion defects and necrosis were also examined postmortem by staining with Phthalo blue and TTC red dyes. Good correlation (R>0.93) in perfused area size was observed between in vivo measurements and histological staining. A 3D multi-slice model and a 3D rendering of perfusion distribution were created and showed a promising match with postmortem results, lending further credence to its use as a more comprehensive and more reliable tool for in vivo assessment of myocardial perfusion than 2D tomographic analysis.

  14. Non-ECG-gated CT pulmonary angiography and the prediction of right ventricular dysfunction in patients suspected of pulmonary embolism

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Mørk, Mette Louise;

    2016-01-01

    PURPOSE: Right ventricular dysfunction (RVD) is an important prognostic factor of 30-day mortality in patients with acute pulmonary embolism (PE). The aim of our study was to evaluate whether non-electrocardiogram (ECG)-gated cardiovascular parameters attained during computed tomography pulmonary...... angiography (CTPA) could predict RVD in patients suspected of PE using ECG-gated cardiac CT angiography as reference. METHODS: Consecutive patients suspected of PE were referred to a ventilation/perfusion single-photon emission tomography (V/Q-SPECT) as first-line imaging procedure. Patients had a V....../Q-SPECT/CT, a CTPA and an ECG-gated cardiac CT angiography performed the same day. RESULTS: A total of 71 patients were available for analysis. Seventeen patients (24%) had RVD. The non-ECG-gated dimensions of left and right ventricle and the major vessels were correlated with ECG-gated cardiac dimensions. The size...

  15. Measuring myocardial perfusion

    DEFF Research Database (Denmark)

    Qayyum, A A; Kastrup, J

    2015-01-01

    -pass of non-ionic and ionic contrast agents, respectively. Absolute quantification with CMR has yet to be established in routine clinical practice, while CT has yet to prove its diagnostic and prognostic value. The upcoming years may change the way we diagnose and treat patients suspected of having CAD......Recently, focus has changed from anatomical assessment of coronary arteries towards functional testing to evaluate the effect of stenosis on the myocardium before intervention. Besides positron-emission tomography (PET), cardiac MRI (CMR), and cardiac CT are able to measure myocardial perfusion...

  16. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...

  17. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...

  18. Assessment of myocardial perfusion and function in victims of scorpion envenomation using gated-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, Alexandre Baldini de; Cupo, Palmira; Pintya, Antonio O.; Caligaris, Fabio; Marin-Neto, Jose A; Hering, Sylvia E.; Simoes, Marcus Vinicius, E-mail: simoesmv@yahoo.co [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2010-04-15

    Background: cardiogenic shock and acute pulmonary edema are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. Objective: to investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. Methods: fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT) within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent) and motion score (0 = normal, 4 akinesia), using the 17-segment model. Summed perfusion (SPS) and summed motion (SMS) scores were calculated for each patient. Ejection fraction (LVEF) was calculated by a commercially available software. Results: at baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 +- 7.3, 17.0 +- 12.8, and 44.6 +- 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005) and negative correlation between SPS and LVEF (r -0.75; p = 0.0021) were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 +- 9.5, p = 0.0002), segmental contractility (SMS of 2.6 +- 3.1, p = 0.0009) and perfusion (SPS of 3.7 +- 3.3, p = 0.0003). Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035). Conclusions: myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (author)

  19. Dynamic CT myocardial perfusion imaging.

    Science.gov (United States)

    Caruso, Damiano; Eid, Marwen; Schoepf, U Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie; Spandorfer, Adam; Laghi, Andrea; De Cecco, Carlo N

    2016-10-01

    Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  20. Dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  1. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...

  2. Fetal Electrocardiogram (fECG Gated MRI

    Directory of Open Access Journals (Sweden)

    Martyn N.J. Paley

    2013-08-01

    Full Text Available We have developed a Magnetic Resonance Imaging (MRI-compatible system to enable gating of a scanner to the heartbeat of a foetus for cardiac, umbilical cord flow and other possible imaging applications. We performed radiofrequency safety testing prior to a fetal electrocardiogram (fECG gated imaging study in pregnant volunteers (n = 3. A compact monitoring device with advanced software capable of reliably detecting both the maternal electrocardiogram (mECG and fECG simultaneously was modified by the manufacturer (Monica Healthcare, Nottingham, UK to provide an external TTL trigger signal from the detected fECG which could be used to trigger a standard 1.5 T MR (GE Healthcare, Milwaukee, WI, USA gating system with suitable attenuation. The MR scanner was tested by triggering rapidly during image acquisition at a typical fetal heart rate (123 beats per minute using a simulated fECG waveform fed into the gating system. Gated MR images were also acquired from volunteers who were attending for a repeat fetal Central Nervous System (CNS examination using an additional rapid cardiac imaging sequence triggered from the measured fECG. No adverse safety effects were encountered. This is the first time fECG gating has been used with MRI and opens up a range of new possibilities to study a developing foetus.

  3. The Effectiveness of Non-ECG-Gated Contrast-Enhanced Computed Tomography for the Diagnosis of Non-ST Segment Elevation Acute Coronary Syndrome.

    Science.gov (United States)

    Watanabe, Tomomi; Furuse, Yoshiyuki; Ohta, Yasutoshi; Kato, Masahiko; Ogawa, Toshihide; Yamamoto, Kazuhiro

    2016-09-28

    Non-ST segment elevation acute coronary syndrome (NSTE-ACS) can be difficult to diagnose accurately, especially in the hyper-acute phase. Non-ECG-gated contrast-enhanced computed tomography (non-ECG-gated CE-CT) has been used in many institutions for screening acute chest pain. Although early defects (EDs) observed in non-ECG-gated CE-CT have been reported as a sign of acute myocardial ischemia, the precise diagnostic value of this sign for acute coronary syndrome has not been fully elucidated. We investigated the usefulness of non-ECG-gated CE-CT for the diagnosis of NSTE-ACS. We retrospectively reviewed 556 patients who were hospitalized for acute-onset chest pain and who underwent emergent coronary angiography. Non-ECG-gated CE-CT was performed in 23 of these patients. Two readers independently analyzed CT images using a 5-point scale. Of the 23 patients, 13 were diagnosed with NSTE-ACS. The remaining 10 patients were diagnosed with other conditions. The sensitivity, specificity, positive predictive value, and negative predictive value, respectively, of EDs on non-ECG-gated CE-CT to detect NSTE-ACS were 84.6%, 90%, 91.7%, and 81.8%. The identification of EDs was consistent between the two readers. Non-ECG-gated CE-CT may be useful not only to triage patients with chest pain by ruling out other conditions, but also to accurately diagnose NSTE-ACS.

  4. Myocardial perfusion scintigraphy in Europe 2007: a survey of the European Council of Nuclear Cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, Eliana; Underwood, S.R. [Royal Brompton Hospital, Nuclear Medicine Department, London (United Kingdom); Wiener, Susanna [European Council of Nuclear Cardiology, Vienna (Austria)

    2012-01-15

    This is the second of a series of surveys designed to assess myocardial perfusion scintigraphy (MPS) practice in Europe. Data were collected from 258 centres in 18 countries. The number of MPS studies per million population (pmp) was estimated assuming that the nonresponding centres performed either no studies (lower estimate) or the same number as the responding centres (upper estimate). The responding centres served 24% of the population of their countries. The total number of noncardiac nuclear medicine studies was between 2,160 and 8,000 studies pmp. The total number of MPS studies was between 529 and 2,293 pmp. The median number of MPS studies per centre was 571 per year with 57% performing fewer than 500 studies per year and 23% of centres performing fewer than 250 studies per year. There was significant variation between countries, with higher numbers of MPS studies (lower limit of estimate above the mid-range of all countries combined) in Austria, Denmark, Hungary, Portugal and Slovenia, and lower numbers (upper limit of estimate below the mid-range of all countries) in Finland, Norway, Spain and Switzerland. The ratio of MPS to coronary angiography to revascularization procedures was 0.9 to 2.2 to 1. Pharmacological stress was used in 57% and technetium-99m-labelled tracers in 88% of studies. ECG gating was performed in 74% of studies and attenuation correction in 22%. MPS utilization in Europe remains low compared with coronary angiography although there has been a 21% increase in the number of studies pmp in centres that reported in both 2005 and 2007. Pharmacological agents continue to be the predominant form of stress. Despite the widespread use of technetium-99m-labelled tracers, ECG gating is not universally performed. As in the 2005 survey, imaging aids such as attenuation and motion correction and prone imaging are not commonly used. (orig.)

  5. A pilot study on diagnosis of coronary artery disease using computed tomography first-pass myocardial perfusion imaging at rest

    Institute of Scientific and Technical Information of China (English)

    Qi WANG; Jing QIN; Lu-yue GAI; Yun-dai CHEN; Wei DONG; Zhi-wei GUAN; Zhi-guo WANG; Zhi-jun SUN; Jia-he TIAN

    2011-01-01

    Background: Although computed tomography coronary angiography (CTCA) can identify coronary stenosis, little data exists on the ability of multislice computed tomography (MSCT) to detect myocardial perfusion defects at rest. Methods: In 33 patients with diagnosed or suspected coronary artery disease (CAD), CTCA using retrospective electrocardiography (ECG) gating at rest and invasive coronary angiography (ICA) was performed. The 2D myocardial images were reconstructed in diastolic and systolic phases using the same raw data for CTCA. CT values of the myocardium were used as an estimate of myocardial enhancement, which were shown by color mapping. Myocardial ischemia was defined as a pattern of transient endocardial hypo-enhancement at systole and normal enhancement at diastole. The results of ICA were taken as the reference standard. Results: When a diameter reduction of more than 50% in ICA was used as diagnostic criteria of CAD, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT first-pass myocardial perfusion imaging (MPI) at rest were 0.85, 0.67, 0.92, and 0.50 per patient, respectively, and 0.58, 0.93, 0.85, and 0.76 per vessel, respectively. Conclusions: CT first-pass MPI at rest could detect CAD patients, which could become a practical and convenient way to detect ischemia, consequently offering the ability for MSCT to act as a "one stop shop" for the diagnosis of CAD.

  6. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  7. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated {sup 82}rubidium myocardial perfusion PET

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Tracy L.Y.; Merrill, Jennifer; Bengel, Frank M. [Johns Hopkins University, Department of Radiology and Radiological Sciences, Division of Nuclear Medicine, Baltimore, MD (United States); Volokh, Lana [GE Healthcare, Haifa (Israel)

    2008-02-15

    Myocardial perfusion imaging with {sup 82}Rb PET allows for ECG-gated studies to be obtained early after radiotracer injection, capturing ventricular function close to peak pharmacologic action of dipyridamole. This is different from gated SPECT and may potentially provide additional diagnostic information. We sought to identify potential correlates of the PET-derived ejection fraction response to vasodilator stress. One hundred ten consecutive patients undergoing {sup 82}Rb PET myocardial perfusion imaging during evaluation for coronary artery disease were included. Using a GE Discovery STRx PET-CT scanner, ECG-gated images (eight bins) were obtained at rest and 4 min after dipyridamole infusion, 90 s after infusion of 1,480-2,220 MBq of {sup 82}Rb. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were determined using a five-point scoring system and 20-segment model. Ejection fraction was calculated using automated QGS software. Significant reversibility (SDS {>=} 4) was found in 23 patients (21%). Mean LVEF in all patients was 47 {+-} 13% at rest and 53 {+-} 13% during dipyridamole. LVEF increased in 89 patients, and decreased in 17 patients during vasodilation. The change in LVEF was inversely correlated with SDS (r = -0.26; p = 0.007). Additionally, it was inversely correlated with resting LVEF (r = -0.20; p = 0.03) and SSS (r = -0.25; p = 0.009). No significant correlations were observed with SRS, heart rate, blood pressure, age, hypertension, hypercholesterolemia, or pretest likelihood of disease. At multivariate regression analysis, SDS was an independent predictor of the change in LVEF. Gated {sup 82}Rb PET during pharmacologic stress allows for assessment of the functional response to vasodilation. The magnitude of LVEF increase is determined by stress perfusion/reversible perfusion defects. Functional response to hyperemia may thus be incorporated in future evaluations of diagnostic and prognostic algorithms based on {sup 82}Rb PET. (orig.)

  8. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room

    Directory of Open Access Journals (Sweden)

    Ballinger Michelle R

    2008-01-01

    Full Text Available Abstract Treadmill exercise stress testing is an essential tool in the prevention, detection, and treatment of a broad spectrum of cardiovascular disease. After maximal exercise, cardiac images at peak stress are typically acquired using nuclear scintigraphy or echocardiography, both of which have inherent limitations. Although CMR offers superior image quality, the lack of MRI-compatible exercise and monitoring equipment has prevented the realization of treadmill exercise CMR. It is critical to commence imaging as quickly as possible after exercise to capture exercise-induced cardiac wall motion abnormalities. We modified a commercial treadmill such that it could be safely positioned inside the MRI room to minimize the distance between the treadmill and the scan table. We optimized the treadmill exercise CMR protocol in 20 healthy volunteers and successfully imaged cardiac function and myocardial perfusion at peak stress, followed by viability imaging at rest. Imaging commenced an average of 30 seconds after maximal exercise. Real-time cine of seven slices with no breath-hold and no ECG-gating was completed within 45 seconds of exercise, immediately followed by stress perfusion imaging of three short-axis slices which showed an average time to peak enhancement within 57 seconds of exercise. We observed a 3.1-fold increase in cardiac output and a myocardial perfusion reserve index of 1.9, which agree with reported values for healthy subjects at peak stress. This study successfully demonstrates in-room treadmill exercise CMR in healthy volunteers, but confirmation of feasibility in patients with heart disease is still needed.

  9. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.;

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper review...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8......Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...

  10. Intracoronary adenosine improves myocardial perfusion in late reperfused myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Background Myocardial perfusion associates with clinical syndromes and prognosis.Adenosine could improve myocardial perfusion of acute myocardial infarction within 6 hours,but few data are available on late perfusion of myocardial infarction (MI).This study aimed at quantitatively evaluating the value of intracoronary adenosine improving myocardial perfusion in late reperfused MI with myocardial contrast echocardiography(MCE).Methods Twenty-six patients with anterior wall infarcts were divided randomly into 2 groups:adenosine group(n=12) and normal saline group(n=14).Their history of myocardial infarction was about 3-12 weeks.Adenosine or normalsaline was given when the guiding wire crossed the lesion through percutaneous coronary intervention(PCI),then the balloon was dilated and stent(Cypher/Cypher select)was implanted at the lesion.Contrast pulse sequencing MCE with Sonovue contrast via the coronary route was done before PCI and 30 minutes after PCI.Video densitometry and contrast filled-blank area were calculated with the CUSQ off-line software.Heart function and cardiac events were followed up within 30 days.Results Perfusion in the segments of the criminal occlusive coronary artery in the adenosine group was better than that in the saline group(5.71±0.29 vs 4.95±1.22,P<0.05).Ischemic myocardial segment was deminished significantly afterPCI,but the meliorated area was bigger in the adenosine group than in the saline group((1.56±0.60)cm2 vs(1.02±0.56) cm2,P<0.05).The video densitometry in critical segments was also improved significantly in the adenosine group (5.53±0.36 vs 5.26±0.35,P<0.05).Left ventricular ejection fraction(LVEF)was improved in all patients after PCI,but EF was not significant between the two groups((67±6)% vs(62±7)%,P>0.05).There was no in-hospital or 30-day major adverse cardiac event(MACE)in the adenosine group but 3 MACE in the saline group in 30 days after PCI.Conclusions Adenosine could improve myocardial microvascular

  11. Diagnostic quality of time-averaged ECG-gated CT data

    NARCIS (Netherlands)

    Klein, A.; Oostveen, L.J.; Greuter, M.J.W.; Hoogeveen, Y.; Schultze Kool, L.J.; Slump, C.H.; Renema, W.K.J.; Samei, Ehsan; Hsieh, Jiang

    2009-01-01

    Purpose: ECG-gated CTA allows visualization of the aneurysm and stentgraft during the different phases of the cardiac cycle, although with a lower SNR per cardiac phase than without ECG gating using the same dose. In our institution, abdominal aortic aneurysm (AAA) is evaluated using non-ECG-gated C

  12. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  13. Nonrigid registration of myocardial perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur

    2005-01-01

    This paper describes a fully automatic registration of 10 multi-slice myocardial perfusion magnetic resonance image sequences. The registration of these sequences is crucial for the clinical interpretation, which currently is subjected to manual labour. The approach used in this study is a nonrig...

  14. Myocardial perfusion at fatal infarction

    DEFF Research Database (Denmark)

    Hvid-Jacobsen, K; Møller, J T; Kjøller, E;

    1992-01-01

    In a consecutive study of myocardial scintigraphy in acute ischemic syndrome, four patients had 99mTc-hexamibi injected intravenously before they developed fatal cardiogenic shock. Planar scintigraphy was performed after death. Slices of the hearts after autopsy were analyzed for scintigraphic......, where 83%-92% of the myocardium showed ischemia as defined by a 99mTc-hexamibi uptake below an arbitrary limit on half maximum uptake. Myocardial hypoperfusion might thus aggravate the functional impairment at myocardial infarction and lead to cardiogenic shock....

  15. Myocardial perfusion imaging with dual energy CT.

    Science.gov (United States)

    Jin, Kwang Nam; De Cecco, Carlo N; Caruso, Damiano; Tesche, Christian; Spandorfer, Adam; Varga-Szemes, Akos; Schoepf, U Joseph

    2016-10-01

    Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  16. An alternative method for neonatal cerebro-myocardial perfusion

    Science.gov (United States)

    Luciani, Giovanni Battista; De Rita, Fabrizio; Faggian, Giuseppe; Mazzucco, Alessandro

    2012-01-01

    Several techniques have already been described for selective cerebral perfusion during repair of aortic arch pathology in children. One method combining cerebral with myocardial perfusion has also been proposed. A novel technique is reported here for selective and independent cerebro-myocardial perfusion for neonatal and infant arch surgery. Technical aspects and potential advantages are discussed. PMID:22307393

  17. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  18. Myocardial perfusion reserve compared with peripheral perfusion reserve : A [13N]ammonia PET study

    NARCIS (Netherlands)

    Scholtens, A. M.; Tio, R. A.; Willemsen, A.; Dierckx, R. A. J. O.; Boersma, Hendrikus; Zeebregts, C. J.; Glaudemans, A. W. J. M.; Slart, R. H. J. A.

    2011-01-01

    INTRODUCTION: [13N]ammonia PET allows quantification of myocardial perfusion. The similarity between peripheral flow and myocardial perfusion is unclear. We compared perfusion flow in the myocardium with the upper limb during rest and adenosine stress [13N]ammonia PET to establish whether peripheral

  19. Myocardial Perfusion Spect Imaging in Dextrocardia: A Case Report

    Directory of Open Access Journals (Sweden)

    Semra Özdemir

    2013-08-01

    Full Text Available The myocardial perfusion scintigraphy acquisition and analysis present some technical differences in the rare dextrocardia cases. Here we report a case of a 38 year-old woman with dextrocardia who had been applied myocardial perfusion scintigraphy. Presented case showed that the thoracic and abdominal organs had a mirror image with situs inversus totalis type dextrocardia. The incidence of coronary heart disease and life span of people with situs inversus totalis are the same as the normal population. So we may apply myocardial perfusion scintigraphy to this patient group. The current case is presented in order to remind the special applications of myocardial perfusion SPECT imaging in patients with dextrocardia.

  20. Nuclear cardiology: Myocardial perfusion and function

    Energy Technology Data Exchange (ETDEWEB)

    Seldin, D.W. (Lahey Clinic Medical Center, Burlington, MA (United States))

    1991-08-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical; two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references.

  1. Quantification of perfusion and risk stratification by myocardial perfusion SPECT; Quantifizierung der Perfusion und Risikostratifizierung durch die Myokardperfusions-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, Bernd [Ueberoertliche Gemeinschaft (GbR) fuer diagnostische und interventionelle Radiologie und Nuklearmedizin (DIRANUK), Bielefeld (Germany); Klinikum Bielefeld-Mitte (Germany). Klinik fuer Nuklearmedizin; Schaefer, W.M. [Kliniken Maria Hilf GmbH, Krankenhaus St. Franziskus, Moenchengladbach (Germany). Klinik fuer Nuklearmedizin

    2010-06-15

    Myocardial perfusion SPECT detects flow-limiting coronary artery disease with high sensitivity and specificity, enables semiquantification of severity and extensiveness of myocardial ischemia, and furthermore enables reliable assessment of future cardiac events independently of other clinical and diagnostic parameters. A normal myocardial perfusion SPECT is associated with a favorable prognosis and warrants restrictive patient management. Cardiac risk increases in relation to the severity of perfusion abnormalities. Differentiated analysis of quantitative parameters derived from myocardial perfusion SPECT provides effective risk stratification of patients with a large variety of risk factors. (orig.)

  2. The relationship between administered radiopharmaceutical activity in myocardial perfusion scintigraphy and imaging outcome

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, C.N.; Aswegen, A. van; Tout, D.A. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Julious, S.A. [University of Sheffield, Sheffield (United Kingdom); Nunan, T.O. [Guy' s and St Thomas' Hospital NHS Trust, London (United Kingdom); Thomson, W.H. [Sandwell and West Birmingham Hospitals NHS Trust, Birmingham (United Kingdom); Tindale, W.B. [Sheffield Teaching Hospitals, Sheffield (United Kingdom); Underwood, S.R. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Imperial College London, London (United Kingdom); Royal Brompton Hospital, London (United Kingdom)

    2008-02-15

    Lower radiopharmaceutical activities are used for myocardial perfusion scintigraphy (MPS) in the UK than in other countries. There is no evidence to suggest that higher activities improve imaging or clinical outcome. We undertook a multicentre study of the relationship between radiopharmaceutical activity and imaging outcome. Fifty-one patients with clinical referrals for MPS followed a 2-day protocol with an injection of 1,000 MBq {sup 99m}Tc-tetrofosmin for each of the stress and rest images. ECG-gated acquisition was performed in three rotations occupying 25, 35 and 40% of a standard acquisition, and rotations were summed to simulate administered activities of 250, 400, 750 and 1,000 MBq. Each set of images was reported by an experienced physician who was blinded to all clinical information and to the simulated activity. Scores were assigned for image quality, low count, attenuation and reconstruction artefact, segmental tracer uptake, segmental and global defect classification, and confidence in the global classification. The images were reported twice to assess intra-observer variability. Positive relationships were found between administered activity and overall image quality, observer confidence and intra-observer agreement of uptake score, and a negative relationship was found with low-count artefact. For the majority of comparisons, there was no additional improvement with increasing activity from 750 to 1,000 MBq. Intra-observer agreement was found to be better in female patients and in those below average body mass index. We conclude that higher administered radiopharmaceutical activities lead to better quality images and improved surrogate parameters for clinical outcome, but that activities above 750 MBq may be unnecessary in average patients. (orig.)

  3. Myocardial perfusion scintigraphy in Germany in 2009: utilization and state of the practice

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, Oliver; Burchert, Wolfgang [University Hospital of the Ruhr University Bochum, Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Centre North Rhine-Westphalia, Bad Oeynhausen (Germany); Bengel, Frank M. [Hanover University School of Medicine, Department of Nuclear Medicine, Hannover (Germany); Zimmermann, Rainer [Klinikum Pforzheim GmbH, Cardiology Department, Pforzheim (Germany); Dahl, Juergen vom [Kliniken Maria Hilf GmbH, Cardiology Department, Moenchengladbach (Germany); Schaefers, Michael [Westfaelische Wilhelms Universitaet Muenster, European Institute of Molecular Imaging, Muenster (Germany)

    2011-08-15

    Since 2006, the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine, in cooperation with the working group Nuclear Cardiology of the German Cardiac Society, has been surveying the utilization and technical realization of myocardial perfusion scintigraphy (MPS) in Germany. This paper presents the results of the reporting year 2009. A total of 291 centres participated in the inquiry, including 179 private practices (PP), 86 hospitals (HO) and 26 university hospitals (UH). MPS of 98,103 patients were reported. The MPS numbers per million population (pmp) were estimated at 2,360; 76% of the MPS were performed in PP, 17% in HO and 7% in UH. The ratio of MPS to coronary angiography to revascularization was 0.5 to 2.3 to 1. Data from 134 centres which participated in the surveys from 2005 to 2009 showed a decrease in MPS utilization of 2.2%. Nearly half of the MPS were requested by ambulatory care cardiologists. Of all MPS studies, 89% were conducted with {sup 99m}Tc perfusion tracers. Ergometry was the preferred stress test (69%). Adenosine was used in 16%, adenosine + exercise in 7%, dipyridamole in 3%, dipyridamole + exercise in 5% and dobutamine in <1%. Gated single proton emission computed tomography (SPECT) acquisition was performed in 56% of all rest MPS and in 56% of all stress MPS. Both rest and stress MPS were ECG gated in 41%. Only 33% of the centres always performed a quantification of the perfusion studies, whereas 51% did not apply any quantification; 4% of the MPS studies were corrected for attenuation, and 17 centres used transmission sources of 12 CT-based systems. A scan activity of 2,380 MPS pmp is in the upper third of the European range. The ratios to coronary angiography and to revascularization suggest that angiography dominates diagnosis and management of coronary artery disease (CAD). The clinical and technical realizations reveal that the predominant goals of further trainings to optimize MPS are in the field

  4. About myocardial gated-SPECT; Autour de la tomoscintigraphie myocardique synchronisee

    Energy Technology Data Exchange (ETDEWEB)

    Halley, A. [Centre Havrais d' Imagerie Scintigraphique, 76 - Montivilliers (France); Agostini, D. [Centre Hospitalier Universitaire, Service de Medecine Nucleaire 14 - Caen (France)

    2007-12-15

    Over the last decades, myocardial perfusion SPECT has become central in the management of patients with known or suspected coronary artery disease. Ecg-Gating, which allows non only the calculation of left ventricular ejection fraction and ventricular volumes but the analysis of regional wall motion, has become a routine part of clinical protocols. Through several examples, we illustrate the usefulness of this imaging modality and present technical pitfalls. (authors)

  5. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T. [Dept. Medical Radiology, Inst. of Diagnostic Radiology, Univ. Hospital Zurich (Switzerland)

    2004-04-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P<0.05). The summary scores for visualization of bronchial segments for different diastolic reconstructions did not differ significantly. The effective radiation dose and the SNR were significantly higher with the ECG-gated acquisition technique (P<0.05). Conclusion: The bronchial tree is significantly better visualized when using non-ECG-gated MDCT compared to ECG-gated MDCT. Additionally, non-ECG-gated techniques require less radiation exposure. Thus, the current retrospective ECG-gating technique does not provide any additional benefit for 3D visualization of the bronchial tree and VB. (orig.) [German] Ziel: Untersuchung des Einflusses der retrospektiven EKG-Synchronisierung auf

  6. An initial study on the feasibility of diagnosing myocardial ischemia with CT first-pass myocardial perfusion imaging at rest

    Institute of Scientific and Technical Information of China (English)

    汪奇

    2013-01-01

    Objective To assess the feasibility and accuracy of CT first-pass myocardial perfusion imaging(CT first-pass MPI)at rest for diagnosis of myocardial ischemia.Results of adenosine-induced myocardial perfusion scintigraphy(MPS)

  7. Detectability of motions in AAA with ECG-gated CTA: A quantitative study

    NARCIS (Netherlands)

    Klein, Almar; Oostveen, Luuk J.; Greuter, Marcel J.W.; Hoogeveen, Yvonne; Schultze Kool, Leo J.; Slump, Cornelis H.; Renema, W. Klaas Jan

    2009-01-01

    Purpose: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal

  8. Detectability of motions in AAA with ECG-gated CTA: a quantitative study.

    NARCIS (Netherlands)

    Klein, A.; Oostveen, L.J.; Greuter, M.J.; Hoogeveen, Y.L.; Kool, L.J.; Slump, C.H.; Renema, W.K.J.

    2009-01-01

    PURPOSE: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal

  9. Detectability of motions in AAA with ECG-gated CTA : A quantitative study

    NARCIS (Netherlands)

    Klein, Almar; Oostveen, Luuk J.; Greuter, Marcel J. W.; Hoogeveen, Yvonne; Kool, Leo J. Schultze; Slump, Cornelis H.; Renema, W. Klaas Jan

    2009-01-01

    Purpose: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal

  10. CT myocardial perfusion imaging: current status and future directions.

    Science.gov (United States)

    Williams, M C; Newby, D E

    2016-08-01

    Computed tomography (CT) imaging of the heart has advanced rapidly, and it is now possible to perform a comprehensive assessment at a low radiation dose. CT myocardial perfusion imaging can provide additive information to CT coronary angiography, and is particularly useful in patients with heavily calcified coronary arteries or coronary artery stents. A number of protocols are now available for CT myocardial perfusion including static, dynamic, and dual-energy techniques. This review will discuss the current status of CT myocardial perfusion imaging, its clinical application, and future directions for this technology.

  11. Diagnostic value of ECG-gated multidetector computed tomography in the early phase of suspected acute myocarditis. A preliminary comparative study with cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dambrin, Gregoire; Caussin, Christophe; Lancelin, Bernard; Paul, Jean F. [Centre Chirurgical Marie Lannelongue, Departments of Cardiology and Radiology, Le Plessis Robinson (France); Laissy, Jean P.; Serfaty, Jean M. [AP-HP, Hospital Bichat, Department of Radiology, Paris (France)

    2007-02-15

    The aim of the study was to determine the potential diagnostic value of contrast-enhanced echocardiogram (ECG)-gated multidetector computed tomography (MDCT) in the setting of suspected acute myocarditis compared with contrast-enhanced magnetic resonance imaging (MRI). The study group consisted of 12 consecutive patients admitted for suspected acute myocarditis less than 10 days after onset of symptoms. All patients had clinical, electrocardiographic signs, and laboratory findings consistent with the diagnosis. All patients but one (severe claustrophobia) underwent cardiac MRI using T1-weighted delayed-enhancement images after injection of gadolinium. ECG-gated MDCT was performed in all patients and included a first-pass contrast-enhanced acquisition and a delayed acquisition. MRI revealed abnormal focal or multifocal myocardial enhancement and confirmed the diagnosis in 11 patients. The first-pass MDCT acquisition showed homogenous left-ventricle contrast enhancement and absence of coronary stenosis in all patients. Delayed MDCT acquisition, performed 5 min later without reinjection of contrast medium revealed multiple areas of myocardial hyperenhancement in a focal or a multifocal pattern (six and six patients, respectively). Extent and location of hyperenhancement at MDCT correlated well with that observed at MR examination for all 11 patients evaluated by both techniques (r=0.9167, p=0.0004). These preliminary results show that ECG-gated MDCT could be a useful alternative noninvasive diagnostic test in the early phase of acute myocarditis. (orig.)

  12. Decreased myocardial perfusion reserve in diabetic autonomic neuropathy

    DEFF Research Database (Denmark)

    Taskiran, Mustafa; Fritz-Hansen, Thomas; Rasmussen, Verner

    2002-01-01

    The pathophysiological mechanisms responsible for increased cardiovascular mortality in diabetic autonomic neuropathy are unknown. To investigate the effect of autonomic neuropathy on myocardial function, we performed dynamic contrast-enhanced magnetic resonance perfusion imaging during baseline...... conditions and after Dipyridamole-induced vasodilatation in nine type 1 diabetic patients with autonomic neuropathy (AN+), defined by cardiovascular tests, as well as in 10 type 1 diabetic patients without autonomic neuropathy (AN-) and 10 healthy control subjects. Baseline myocardial perfusion index (K...... blood pressure response to Dipyridamole and myocardial perfusion reserve index. We conclude that type 1 diabetic patients with autonomic neuropathy have a decreased myocardial perfusion reserve capacity when challenged with a vasodilatator, a finding that may in part be the pathophysiological substrate...

  13. Myocardial Perfusion Scintigraphy: Techniques, Interpretation, Indications and Reporting

    OpenAIRE

    Fathala, Ahmed

    2011-01-01

    Myocardial perfusion single photon emission-computed tomography (MPS) has been one of the most important and common non-invasive diagnostic cardiac test. Gated MPS provides simultaneous assessment of myocardial perfusion and function with only one study. With appropriate attention to the MPS techniques, appropriate clinical utilization and effective reporting, gated MPS will remain a useful diagnostic test for many years to come. The aim of this article is to review the basic techniques of MP...

  14. Measuring myocardial perfusion: the role of PET, MRI and CT.

    Science.gov (United States)

    Qayyum, A A; Kastrup, J

    2015-06-01

    Recently, focus has changed from anatomical assessment of coronary arteries towards functional testing to evaluate the effect of stenosis on the myocardium before intervention. Besides positron-emission tomography (PET), cardiac MRI (CMR), and cardiac CT are able to measure myocardial perfusion. Myocardial perfusion abnormalities are the first sign of the ischaemic cascade in the development of coronary artery disease (CAD). PET is considered the non-invasive clinical reference standard for absolute quantification of myocardial perfusion. The diagnostic and prognostic value of PET is well-known and is used in routine clinical practice. However, PET uses radioactive tracers and has a lower spatial resolution compared to CMR and CT. CMR and CT are emerging techniques in the field of myocardial perfusion imaging. CMR uses magnetic resonance to obtain images, whereas CT uses x-rays during first-pass of non-ionic and ionic contrast agents, respectively. Absolute quantification with CMR has yet to be established in routine clinical practice, while CT has yet to prove its diagnostic and prognostic value. The upcoming years may change the way we diagnose and treat patients suspected of having CAD with more precise methods for measuring myocardial perfusion. The aim of this comprehensive review is to discuss current and emerging imaging techniques used for myocardial perfusion imaging.

  15. PET and MRI for the evaluation of regional myocardial perfusion and wall thickening after myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Slart, Riemer H.J.A.; Golestani, Reza; Glaudemans, Andor W.J.M. [University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); Glauche, Julius; Jansen, Jan W. [University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, University of Groningen, Department of Cardiology, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, University of Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); Dierckx, Rudi A.J.O. [University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); Ghent University Hospital, Department of Nuclear Medicine, Ghent (Belgium); Oudkerk, Matthijs; Willems, Tineke P. [University Medical Center Groningen, University of Groningen, Department of Radiology, Groningen (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, University of Groningen, Department of Nuclear Medicine and Molecular Imaging, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, University of Groningen, Clinical and Hospital Pharmacy, Groningen (Netherlands); Tio, Rene A. [University Medical Center Groningen, University of Groningen, Department of Cardiology, Groningen (Netherlands)

    2012-06-15

    Deterioration of left ventricular (LV) function after myocardial infarction (MI) is a major cause of heart failure. Myocardial perfusion performance may play an important role in deterioration or improvement in LV function after MI. The aim of this study was to evaluate the myocardial perfusion reserve (MPR) and stress perfusion in deteriorating and non-deteriorating LV segments in patients after MI by PET and MRI, respectively. Regional wall thickening of 352 segments in 22 patients was assessed at 4 and 24 months after MI by cardiac MRI. PET was performed to evaluate MPR and adenosine stress {sup 13}N-ammonia perfusion 24 months after MI. Segments were divided into four groups according to deterioration or improvement in wall thickening. Normal functional segments at 4 months after MI that remained stable had a significantly higher mean MPR and mean stress perfusion PET value than deteriorated segments (p < 0.001). Furthermore, dysfunctional segments that improved had a significantly higher mean stress perfusion PET value than dysfunctional segments that remained dysfunctional (p < 0.001). This study demonstrated the additional value of myocardial perfusion assessment in relation to the functional integrity of the injured myocardium. Segmental functional LV improvement after MI was associated with better regional myocardial perfusion characteristics. Furthermore, the amount of wall thickening reduction was associated with regional myocardial perfusion abnormalities in patients after MI. (orig.)

  16. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Bastarrika, Gorka [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Cardiac Imaging Unit, Clinica Univ. de Navarra, Pamplona (Spain)], e-mail: bastarrika@unav.es

    2012-06-15

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 {+-} 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 {+-} 58.3 mL) with respect to ECG-gated CT (142.7 {+-} 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 {+-} 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.

  17. Quantification of Intracranial Aneurysm Morphodynamics from ECG-gated CT Angiography

    NARCIS (Netherlands)

    Firouzian, A.; Manniesing, R.; Metz, C.T.; Risselada, R.; Klein, S.; Kooten, F. van; Sturkenboom, M.C.; Lugt, A. van der; Niessen, W.J.

    2013-01-01

    Rationale and Objectives: Aneurysm morphodynamics is potentially relevant for assessing aneurysm rupture risk. A method is proposed for automated quantification and visualization of intracranial aneurysm morphodynamics from ECG-gated computed tomography angiography (CTA) data. Materials and Methods:

  18. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  19. An integrated bioimpedance—ECG gating technique for respiratory and cardiac motion compensation in cardiac PET

    Science.gov (United States)

    Koivumäki, Tuomas; Nekolla, Stephan G.; Fürst, Sebastian; Loher, Simone; Vauhkonen, Marko; Schwaiger, Markus; Hakulinen, Mikko A.

    2014-10-01

    Respiratory motion may degrade image quality in cardiac PET imaging. Since cardiac PET studies often involve cardiac gating by ECG, a separate respiratory monitoring system is required increasing the logistic complexity of the examination, in case respiratory gating is also needed. Thus, we investigated the simultaneous acquisition of both respiratory and cardiac gating signals using II limb lead mimicking electrode configuration during cardiac PET scans of 11 patients. In addition to conventional static and ECG-gated images, bioimpedance technique was utilized to generate respiratory- and dual-gated images. The ability of the bioimpedance technique to monitor intrathoracic respiratory motion was assessed estimating cardiac displacement between end-inspiration and -expiration. The relevance of dual gating was evaluated in left ventricular volume and myocardial wall thickness measurements. An average 7.6  ±  3.3 mm respiratory motion was observed in the study population. Dual gating showed a small but significant increase (4 ml, p = 0.042) in left ventricular myocardial volume compared to plain cardiac gating. In addition, a thinner myocardial wall was observed in dual-gated images (9.3  ±  1.3 mm) compared to cardiac-gated images (11.3  ±  1.3 mm, p = 0.003). This study shows the feasibility of bioimpedance measurements for dual gating in a clinical setting. The method enables simultaneous acquisition of respiratory and cardiac gating signals using a single device with standard ECG electrodes.

  20. Radionuclide Tracers for Myocardial Perfusion Imaging and Blood Flow Quantification.

    Science.gov (United States)

    deKemp, Robert A; Renaud, Jennifer M; Klein, Ran; Beanlands, Rob S B

    2016-02-01

    Myocardial perfusion imaging is performed most commonly using Tc-99m-sestamibi or tetrofosmin SPECT as well as Rb-82-rubidium or N-13-ammonia PET. Diseased-to-normal tissue contrast is determined by the tracer retention fraction, which decreases nonlinearly with flow. Reduced tissue perfusion results in reduced tracer retention, but the severity of perfusion defects is typically underestimated by 20% to 40%. Compared to SPECT, retention of the PET tracers is more linearly related to flow, and therefore, the perfusion defects are measured more accurately using N-13-ammonia or Rb-82.

  1. Adenosine stress protocols for myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2008-01-01

    Full Text Available Background/Aim. Treadmill test combined with myocardial perfusion scintigraphy (MPS is a commonly used technique in the assessment of coronary artery disease. There are many patients, however, who may not be able to undergo treadmill test. Such patients would benefit from pharmacological stress procedures combined with MPS. The most commonly used pharmacological agents for cardiac stress are coronary vasodilatators (adenosine, dipyridamol and catecholamines. Concomitant low-level treadmill exercise with adenosine pharmacologic stress (AdenoEX during MPS has become commonly used in recent years. A number of studies have demonstrated a beneficial impact of AdenoEX protocol. The aim of the study was, besides introducing into practice the two types of protocols of pharmatological stress test with adenosine, as a preparation for MPS, to compare and monitor the frequency of their side effects to quality, acquisition, as well as to standardize the onset time of acquisition (diagnostic imaging for both protocols. Methods. A total of 130 patients underwent pharmacological stress test with adenosine (vasodilatator. In 108 of the patients we performed concomitant exercise (AdenoEX of low level (50W by a bicycle ergometar. In 28 of the patients we performed Adenosine abbreviated protocol (AdenoSCAN. Side effects of adenosine were followed and compared between the two kinds of protocols AdenoEX and AdenoSCAN. Also compared were image quality and suggested time of acquisition after the stress test. Results. Numerous side effects were found, but being short-lived they did not require any active interventions. The benefit of AdenoEX versus AdenoSCAN included decreased side effects (62% vs 87%, improved safety and patients tolerance, improved target-to-background ratios because of less subdiaphragmatic activity, earlier acquisition, and improved sensitivity. Conclusion. The safety and efficacy of adenosine pharmacological stress is even better with concomitant

  2. ECG-gated computed tomography: a new role for patients with suspected aortic prosthetic valve endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Fagman, Erika; Flinck, Agneta; Lamm, Carl [Sahlgrenska University Hospital, Department of Radiology, Gothenburg (Sweden); Perrotta, Sossio [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); Bech-Hanssen, Odd [Sahlgrenska University Hospital, Department of Clinical Physiology, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Cardiology, Gothenburg (Sweden); Olaison, Lars [Sahlgrenska University Hospital, Department of Infectious Diseases, Gothenburg (Sweden); Svensson, Gunnar [Sahlgrenska University Hospital, Department of Cardiovascular Surgery and Anaesthesia, Gothenburg (Sweden); The Sahlgrenska Academy at the University of Gothenburg, Department of Molecular and Clinical Medicine, Institute of Medicine, Gothenburg (Sweden)

    2012-11-15

    The aim of this prospective study was to investigate the agreement in findings between ECG-gated CT and transoesophageal echocardiography (TEE) in patients with aortic prosthetic valve endocarditis (PVE). Twenty-seven consecutive patients with PVE underwent 64-slice ECG-gated CT and TEE and the results were compared. Imaging was compared with surgical findings (surgery was performed in 16 patients). TEE suggested the presence of PVE in all patients [thickened aortic wall (n = 17), vegetation (n = 13), abscess (n = 16), valvular dehiscence (n = 10)]. ECG-gated CT was positive in 25 patients (93 %) [thickened aortic wall (n = 19), vegetation (n = 7), abscess (n = 18), valvular dehiscence (n = 7)]. The strength of agreement [kappa (95 % CI)] between ECG-gated CT and TEE was very good for thickened wall [0.83 (0.62-1.0)], good for abscess [0.68 (0.40-0.97)] and dehiscence [0.75 (0.48-1.0)], and moderate for vegetation [0.55 (0.26-0.88)]. The agreement was good between surgical findings (abscess, vegetation and dehiscence) and imaging for ECG-gated CT [0.66 (0.49-0.87)] and TEE [0.79 (0.62-0.96)] and very good for the combination of ECG-gated CT and TEE [0.88 (0.74-1.0)]. Our results indicate that ECG-gated CT has comparable diagnostic performance to TEE and may be a valuable complement in the preoperative evaluation of patients with aortic PVE. (orig.)

  3. Automatic Characterization of Myocardial Perfusion in Contrast Enhanced MRI

    Science.gov (United States)

    Positano, Vincenzo; Santarelli, Maria Filomena; Landini, Luigi

    2003-12-01

    The use of contrast medium in cardiac MRI allows joining the high-resolution anatomical information provided by standard magnetic resonance with functional information obtained by means of the perfusion of contrast agent in myocardial tissues. The current approach to perfusion MRI characterization is the qualitative one, based on visual inspection of images. Moving to quantitative analysis requires extraction of numerical indices of myocardium perfusion by analysis of time/intensity curves related to the area of interest. The main problem in quantitative image sequence analysis is the heart movement, mainly due to patient respiration. We propose an automatic procedure based on image registration, segmentation of the myocardium, and extraction and analysis of time/intensity curves. The procedure requires a minimal user interaction, is robust with respect to the user input, and allows effective characterization of myocardial perfusion. The algorithm was tested on cardiac MR images acquired from voluntaries and in clinical routine.

  4. Quantification of MRI measured myocardial perfusion reserve in healthy humans: a comparison with positron emission tomography

    DEFF Research Database (Denmark)

    Fritz-Hansen, Thomas; Hove, Jens D; Kofoed, Klaus F

    2008-01-01

    PURPOSE: To validate a noninvasive quantitative MRI technique, the K(i) perfusion method, for myocardial perfusion in humans using (13)N-ammonia PET as a reference method. MATERIALS AND METHODS: Ten healthy males (64 +/- 8 years) were examined with combined PET and MRI perfusion imaging at rest...... and during stress induced by dipyridamole in order to determine the myocardial perfusion reserve. Myocardial and blood time concentration curves obtained by Gd-DTPA-enhanced MRI and (13)N-ammonia PET were fitted by a two-compartment perfusion model. RESULTS: Mean perfusion values (+/-SD) derived from the MRI...... as a quantitative marker for myocardial perfusion in healthy humans....

  5. Regional time-density measurement of myocardial perfusion

    Science.gov (United States)

    Eusemann, Christian D.; Breen, Jerome F.; Robb, Richard A.

    2003-05-01

    The measurement of time-density relationships of the myocardium in studies of Magnetic Resonance perfusion data sets is a clinical technique used in assessing myocardial perfusion. Traditionally, to measure the time-density relationship a physician draws a region on the same 2-D image of the myocardium in sequential cardiac cycles. Throughout multiple cardiac cycles the density changes in this region are measured. A major limitation of this technique is change in anatomy relative to the selected region on the myocardium during consecutive cardiac cycles. This causes measurement errors, which are amplified if the traced region does not encompass the entire myocardial thickness, or includes a boundary exterior to the epicardial or endocardial surface. The technique described in this paper uses approximately the same myocardial region throughout the entire perfusion study, which insures inclusion of the entire endocardial to epicardial region and exclusion of exterior regions. Moreover, this region can be subdivided into smaller regions of interest. This can be accomplished by careful segmentation and reformatting of the data into polar coordinates. This allows sectioning both axially and transaxially through the myocardium permitting regional assessment of perfusion specific values such as maximum and/or the time to reach maximum density. These values can then be illustrated using density-mapped colors or time-density curves. This measurement and display technique may provide enhanced detection and evaluation of regional deficits in myocardial contractility and perfusion.

  6. Direct myocardial perfusion imaging in valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Soto, R.C.; Durante, M.L.; Villacorta, E.V.; Torres, J.F.; Monzon, O.P.

    1981-02-01

    Twenty two patients with rheumatic valvular heart disease - 21 having a history of heart failure - were studied using direct coronary injection of /sup 99m/Tc labelled MAA particles during the course of hemodynamic and arteriographic studies. Myocardial perfusion deficit patterns have been shown to be consistent or indicative of either patchy, regional or gross ischemia. In patients with history of documented heart failure 90% (18 cases) had ischemic perfusion deficit in the involved ventricle. We conclude that diminished myocardial blood flow is an important mechanism contributing to the development of heart failure.

  7. Myocardial perfusion scintigraphy: techniques, interpretation, indications and reporting.

    Science.gov (United States)

    Fathala, Ahmed

    2011-01-01

    Myocardial perfusion single photon emission-computed tomography (MPS) has been one of the most important and common non-invasive diagnostic cardiac test. Gated MPS provides simultaneous assessment of myocardial perfusion and function with only one study. With appropriate attention to the MPS techniques, appropriate clinical utilization and effective reporting, gated MPS will remain a useful diagnostic test for many years to come. The aim of this article is to review the basic techniques of MPS, a simplified systematic approach for study interpretation, current clinical indications and reporting. After reading this article the reader should develop an understanding of the techniques, interpretation, current clinical indications and reporting of MPS studies.

  8. Use of intravenous dipyridamole in thallium 201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zeller, F.P.; Blend, M.J.

    1987-01-01

    Thallium 201 myocardial perfusion imaging is a standard method of evaluating regional myocardial blood flow. Myocardial perfusion is best evaluated at rest and during exercise, however, alternative methods have been sought to increase coronary blood flow in patients incapable of performing adequate exercise. A promising new method is the use of intravenous dipyridamole for pharmacologic stress imaging. It has distinct advantages over traditional treadmill exercise testing. The primary advantage of combining intravenous dipyridamole and thallium 201 is for testing patients in whom exercise is impractical or contraindicated. Examples include patients taking beta blockers and those who have had myocardial infarction or have severe peripheral vascular disease. To date, this agent has been available only to clinical investigators in approved protocols. With continued success, it should be approved for general use in the near future. 33 references.

  9. Semi-quantitative myocardial perfusion measured by computed tomography in patients with refractory angina

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Kühl, Jørgen Tobias; Kjaer, Andreas

    2017-01-01

    INTRODUCTION: Computed tomography (CT) is a novel method for assessment of myocardial perfusion and has not yet been compared to rubidium-82 positron emission tomography (PET). We aimed to compare CT measured semi-quantitative myocardial perfusion with absolute quantified myocardial perfusion using...

  10. Evaluation of the therapeutic effect of hyperbaric oxygenation and erythropoietin in the treatment of chronic heart failure using myocardial perfusion scintigraphy G-SPECT

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2009-01-01

    Full Text Available Background. The most important predictors of longterm survival in patients with cardiac ischemic disease are left ventricular ejection fraction, left ventricular volumes, infarction size, presence and extent of residual myocardial ischemia. One of the most important recent developments in single photon emission computed tomography (SPECT myocardial perfusion imaging is the ability to acquire these studies in conjunction with electrocardiogram (ECG gating (G-SPECT. The ability to asses radionuclide myocardial perfusion and function with ECG G-SPECT imaging has revolutionized this field of nuclear cardiology. Study with G-SPECT development algorithms permits to quantify measures of left ventricular (LV volume, ejection fraction (LVEF and even regional myocardial wall motion and thickening. The American Society of Nuclear Cardiology (ASNC in its position paper from March 1999 recommends the routine incorporation of G-SPECT during cardiac perfusion scintigraphy. Case report. We presented a 70-year-old male with ischemic heart disease (dilatative, cardiomyopathy and absolute arrhythmia. He was few times hospitally treated by medicamentous therapy with no evidence of improvement. After hospital treatment, we included hyperbaric oxygenation (HBO and erythropoietin injections. Hyperbaric oxygenation was carried out in a monoplace hyperbaric chamber, BLK S-303, by a graduated protocol for patients with severe heart insufficiency, totally 15 treatments. Recombinant erythropoietin beta (RecormonR F. Hoffmann-La Roche was applied deeply subcutaneously, every second day from 2 000 IU to totally 16 000 IU. Before the therapy G-SPECT study was performed with 99m technetium-MIBI, and we obtained the functional parameters and perfusion of the left ventricle to follow-up the therapy effects. The study was performed by an ADAC-VERTEX PLUS-EPIC two-head gamma camera with dedicated quantitatively algorithm Auto-QUANT. The results of LVEF were 15%, with severity

  11. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.

  12. Non-invasive imaging in detecting myocardial viability: Myocardial function versus perfusion

    Directory of Open Access Journals (Sweden)

    Iqbal A. Elfigih

    2014-12-01

    Full Text Available Coronary artery disease (CAD is the most prevalent and single most common cause of morbidity and mortality [1] with the resulting left ventricular (LV dysfunction an important complication. The distinction between viable and non-viable myocardium in patients with LV dysfunction is a clinically important issue among possible candidates for myocardial revascularization. Several available non-invasive techniques are used to detect and assess ischemia and myocardial viability. These techniques include echocardiography, radionuclide images, cardiac magnetic resonance imaging and recently myocardial computed tomography perfusion imaging. This review aims to distinguish between the available non-invasive imaging techniques in detecting signs of functional and perfusion viability and identify those which have the most clinical relevance in detecting myocardial viability in patients with CAD and chronic ischemic LV dysfunction. The most current available studies showed that both myocardial perfusion and function based on non-invasive imaging have high sensitivity with however wide range of specificity for detecting myocardial viability. Both perfusion and function imaging modalities provide complementary information about myocardial viability and no optimum single imaging technique exists that can provide very accurate diagnostic and prognostic viability assessment. The weight of the body of evidence suggested that non-invasive imaging can help in guiding therapeutic decision making in patients with LV dysfunction.

  13. Stress-only myocardial perfusion scintigraphy

    DEFF Research Database (Denmark)

    Ejlersen, June A; May, Ole; Mortensen, Jesper

    2017-01-01

    OBJECTIVE: Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. PATIENTS AND METHODS: A total of 109 patients with typical angina and no pre......OBJECTIVE: Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. PATIENTS AND METHODS: A total of 109 patients with typical angina...... and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert...

  14. Quantitative myocardial perfusion measurement using CT perfusion: a validation study in a porcine model of reperfused acute myocardial infarction.

    Science.gov (United States)

    So, Aaron; Hsieh, Jiang; Li, Jian-Ying; Hadway, Jennifer; Kong, Hua-Fu; Lee, Ting-Yim

    2012-06-01

    We validated a CT perfusion technique with beam hardening (BH) correction for quantitative measurement of myocardial blood flow (MBF). Acute myocardial infarction (AMI) was created in four pigs by occluding the distal LAD for 1 h followed by reperfusion. MBF was measured from dynamic contrast enhanced CT (DCE-CT) scanning of the heart, with correction of cardiac motion and BH, before ischemic insult and on day 7, 10 and 14 post. On day 14 post, radiolabeled microspheres were injected to measure MBF and the results were compared with those measured by CT perfusion. Excised hearts were stained with 2,3,5-triphenyltetrazolium chloride (TTC) to determine the relationship between MBF measured by CT Perfusion and myocardial viability. MBF measured by CT perfusion was strongly correlated with that by microspheres over a wide range of MBF values (R = 0.81, from 25 to 225 ml min(-1) 100 g(-1)). While MBF in the LAD territory decreased significantly from 98.4 ± 2.5 ml min(-1) 100 g(-1) at baseline to 32.2 ± 9.1 ml min(-1) 100 g(-1), P 0.05). TTC staining confirmed incomplete infarction in the LAD territory and no infarction in the LCx territory. Microvascular obstruction in infarcted tissue resulted in no-reflow and hence persistently low MBF in the reperfused LAD territory which contained a mixture of viable and non-viable tissue. CT perfusion measurement of MBF was accurate and correlated well with histology and microspheres measurements.

  15. Normal Databases for the Relative Quantification of Myocardial Perfusion.

    Science.gov (United States)

    Rubeaux, Mathieu; Xu, Yuan; Germano, Guido; Berman, Daniel S; Slomka, Piotr J

    2016-08-01

    Myocardial perfusion imaging (MPI) with SPECT is performed clinically worldwide to detect and monitor coronary artery disease (CAD). MPI allows an objective quantification of myocardial perfusion at stress and rest. This established technique relies on normal databases to compare patient scans against reference normal limits. In this review, we aim to introduce the process of MPI quantification with normal databases and describe the associated perfusion quantitative measures that are used. New equipment and new software reconstruction algorithms have been introduced which require the development of new normal limits. The appearance and regional count variations of normal MPI scan may differ between these new scanners and standard Anger cameras. Therefore, these new systems may require the determination of new normal limits to achieve optimal accuracy in relative myocardial perfusion quantification. Accurate diagnostic and prognostic results rivaling those obtained by expert readers can be obtained by this widely used technique. Throughout this review, we emphasize the importance of the different normal databases and the need for specific databases relative to distinct imaging procedures. use of appropriate normal limits allows optimal quantification of MPI by taking into account subtle image differences due to the hardware and software used, and the population studied.

  16. Quantification of myocardial perfusion defects using three different software packages

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Annmarie; Aakesson, Liz [Department of Clinical Physiology, Malmoe University Hospital, 205 02, Malmoe (Sweden); Edenbrandt, Lars [Department of Clinical Physiology, Malmoe University Hospital, 205 02, Malmoe (Sweden); Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2004-02-01

    Software packages are widely used for quantification of myocardial perfusion defects. The quantification is used to assist the physician in his/her interpretation of the study. The purpose of this study was to compare the quantification of reversible perfusion defects by three different commercially available software packages. We included 50 consecutive patients who underwent myocardial perfusion single-photon emission tomography (SPET) with a 2-day technetium-99m tetrofosmin protocol. Two experienced technologists processed the studies using the following three software packages: Cedars Quantitative Perfusion SPECT, Emory Cardiac Toolbox and 4D-MSPECT. The same sets of short axis slices were used as input to all three software packages. Myocardial uptake was scored in 20 segments for both the rest and the stress studies. The summed difference score (SDS) was calculated for each patient and the SDS values were classified into: normal (<4), mildly abnormal (4-8), moderately abnormal (9-13), and severely abnormal (>13). All three software packages were in agreement that 21 patients had a normal SDS, four patients had a mildly abnormal SDS and one patient had a severely abnormal SDS. In the remaining 24 patients (48%) there was disagreement between the software packages regarding SDS classification. A difference in classification of more than one step between the highest and lowest scores, for example from normal to moderately abnormal or from mildly to severely abnormal, was found in six of these 24 patients. Widely used software packages commonly differ in their quantification of myocardial perfusion defects. The interpreting physician should be aware of these differences when using scoring systems. (orig.)

  17. Effect of physiological heart rate variability on quantitative T2 measurement with ECG-gated Fast Spin Echo (FSE) sequence and its retrospective correction.

    Science.gov (United States)

    de Roquefeuil, Marion; Vuissoz, Pierre-André; Escanyé, Jean-Marie; Felblinger, Jacques

    2013-11-01

    Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject to physiological variability, which causes repetition time variations and affects the recovery of longitudinal magnetization between TR periods. The bias caused by heart rate variability on quantitative T2 measurements is evaluated for fast spin echo pulse sequence. Its retrospective correction based on an effective TR is proposed. Heart rate variations during breath-holds are provided by the ECG recordings from healthy volunteers. T2 measurements were performed on a phantom with known T2 values, by synchronizing the sequence with the recorded ECG. Cardiac T2 measurements were performed twice on six volunteers. The impact of T1 on T2 is also studied. Maximum error in T2 is 26% for phantoms and 18% for myocardial measurement. It is reduced by the proposed compensation method to 20% for phantoms and 10% for in vivo measurements. Only approximate knowledge of T1 is needed for T2 correction. Heart rate variability may cause a bias in T2 measurement with ECG-gated FSE. It needs to be taken into account to avoid a misleading diagnosis from the measurements. © 2013.

  18. Myocardial Perfusion and Function Are Distinctly Altered by Sevoflurane Anesthesia in Diet-Induced Prediabetic Rats

    Directory of Open Access Journals (Sweden)

    Charissa E. van den Brom

    2016-01-01

    Full Text Available Preservation of myocardial perfusion during surgery is particularly important in patients with increased risk for perioperative complications, such as diabetes. Volatile anesthetics, like sevoflurane, have cardiodepressive effects and may aggravate cardiovascular complications. We investigated the effect of sevoflurane on myocardial perfusion and function in prediabetic rats. Rats were fed a western diet (WD; n=18 or control diet (CD; n=18 for 8 weeks and underwent (contrast echocardiography to determine perfusion and function during baseline and sevoflurane exposure. Myocardial perfusion was estimated based on the product of microvascular filling velocity and blood volume. WD-feeding resulted in a prediabetic phenotype characterized by obesity, hyperinsulinemia, hyperlipidemia, glucose intolerance, and hyperglycemia. At baseline, WD-feeding impaired myocardial perfusion and systolic function compared to CD-feeding. Exposure of healthy rats to sevoflurane increased the microvascular filling velocity without altering myocardial perfusion but impaired systolic function. In prediabetic rats, sevoflurane did also not affect myocardial perfusion; however, it further impaired systolic function. Diet-induced prediabetes is associated with impaired myocardial perfusion and function in rats. While sevoflurane further impaired systolic function, it did not affect myocardial perfusion in prediabetic rats. Our findings suggest that sevoflurane anesthesia leads to uncoupling of myocardial perfusion and function, irrespective of the metabolic state.

  19. Myocardial Perfusion and Function Are Distinctly Altered by Sevoflurane Anesthesia in Diet-Induced Prediabetic Rats.

    Science.gov (United States)

    van den Brom, Charissa E; Boly, Chantal A; Bulte, Carolien S E; van den Akker, Rob F P; Kwekkeboom, Rick F J; Loer, Stephan A; Boer, Christa; Bouwman, R Arthur

    2016-01-01

    Preservation of myocardial perfusion during surgery is particularly important in patients with increased risk for perioperative complications, such as diabetes. Volatile anesthetics, like sevoflurane, have cardiodepressive effects and may aggravate cardiovascular complications. We investigated the effect of sevoflurane on myocardial perfusion and function in prediabetic rats. Rats were fed a western diet (WD; n = 18) or control diet (CD; n = 18) for 8 weeks and underwent (contrast) echocardiography to determine perfusion and function during baseline and sevoflurane exposure. Myocardial perfusion was estimated based on the product of microvascular filling velocity and blood volume. WD-feeding resulted in a prediabetic phenotype characterized by obesity, hyperinsulinemia, hyperlipidemia, glucose intolerance, and hyperglycemia. At baseline, WD-feeding impaired myocardial perfusion and systolic function compared to CD-feeding. Exposure of healthy rats to sevoflurane increased the microvascular filling velocity without altering myocardial perfusion but impaired systolic function. In prediabetic rats, sevoflurane did also not affect myocardial perfusion; however, it further impaired systolic function. Diet-induced prediabetes is associated with impaired myocardial perfusion and function in rats. While sevoflurane further impaired systolic function, it did not affect myocardial perfusion in prediabetic rats. Our findings suggest that sevoflurane anesthesia leads to uncoupling of myocardial perfusion and function, irrespective of the metabolic state.

  20. Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Das, Marco; Haberland, Ulrike; Slump, Cees; Handayani, Astri; van Tuijl, Sjoerd; Stijnen, Marco; Klotz, Ernst; Oudkerk, Matthijs; Wildberger, Joachim E.; Vliegenthart, Rozemarijn

    2015-01-01

    Objective. To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory pa

  1. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    OpenAIRE

    Sundaram P; Padma S

    2009-01-01

    Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event–free survival in adults with ischemic heart disease. This article highlights various my...

  2. Diagnostic accuracy of prospective ECG gated coronary computed tomography on a 256 slices scanner: Daily practice experience

    Directory of Open Access Journals (Sweden)

    Ahmed M. Fareed

    2014-03-01

    Conclusions: In a highly prevalence diseased population, prospective ECG-gated CTCA using 256-slice scanner is highly accurate for detection and quantification of the degree of coronary luminal stenosis in comparison to ICA.

  3. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.

  4. Myocardial Perfusion SPECT Imaging in Patients after Percutaneous Coronary Intervention.

    Science.gov (United States)

    Georgoulias, Panagiotis; Valotassiou, Varvara; Tsougos, Ioannis; Demakopoulos, Nikolaos

    2010-05-01

    Coronary artery disease (CAD) is the most prevalent form of cardiovascular disease affecting about 13 million Americans, while more than one million percutaneous transluminal intervention (PCI) procedures are performed annually in the USA. The relative high occurrence of restenosis, despite stent implementation, seems to be the primary limitation of PCI. Over the last decades, single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), has proven an invaluable tool for the diagnosis of CAD and patients' risk stratification, providing useful information regarding the decision about revascularization and is well suited to assess patients after intervention. Information gained from post-intervention MPI is crucial to differentiate patients with angina from those with exo-cardiac chest pain syndromes, to assess peri-intervention myocardial damage, to predict-detect restenosis after PCI, to detect CAD progression in non-revascularized vessels, to evaluate the effects of intervention if required for occupational reasons and to evaluate patients' long-term prognosis. On the other hand, chest pain and exercise electrocardiography are largely unhelpful in identifying patients at risk after PCI.Although there are enough published data demonstrating the value of myocardial perfusion SPECT imaging in patients after PCI, there is still debate on whether or not these tests should be performed routinely.

  5. Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yu.; Fan, Zhanming; Xu, Lei; Yang, Lin; Xin, Haiyan; Zhang, Nan [Capital Medical University, Department of Radiology, Beijing An Zhen Hospital, Beijing (China); Capital Medical University, Ministry of Education, The Key Laboratory of Remodeling-Related Cardiovascular Diseases, Beijing An Zhen Hospital, Beijing (China); Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing An Zhen Hospital, Beijing (China)

    2012-11-15

    To investigate the feasibility of using a prospective ECG-gated wide-volume protocol in CT angiography (CTA) of the whole aorta and coronary arteries (CA). A total of 61 consecutive patients with suspected acute aortic diseases underwent CTA of the whole aorta using a prospective ECG-gated wide-volume CT protocol without heart rate (HR) control. The exposure window was set at 40-50 % of R-R interval (HR {>=}70 bpm) or 70-80 % of R-R interval (HR <70 bpm) in a single heartbeat. The image quality of the ascending aorta, aortic valve and CA was evaluated for motion artefacts. The mean attenuation was measured at different levels of the aorta. The radiation dose and contrast medium volume were recorded. All of the examinations were performed successfully. The image quality was acceptable in the ascending aorta, aortic valve (100 %) and CA (94.4 %). The mean radiation dose was 18.42 {+-} 5.02 mSv. Of 61 patients, 14 were diagnosed with aortic aneurysm and 35 were diagnosed with aortic dissection or intramural haematoma. Coronary artery stenosis was detected in 12 patients. For patients with aortic diseases, CTA of the whole aorta using a prospective ECG-gated wide-volume protocol has the potential to provide additional information about the CA and aortic valve with lower radiation exposure. (orig.)

  6. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    Science.gov (United States)

    Schwemmer, C.; Rohkohl, C.; Lauritsch, G.; Müller, K.; Hornegger, J.

    2013-06-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D-2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average.

  7. Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Hove, J.D.; Kofoed, K.F.;

    2008-01-01

    and during stress induced by dipyridamole in order to determine the myocardial perfusion reserve. Myocardial and blood time concentration curves obtained by Gd-DTPA-enhanced MRI and N-13-ammonia PET were fitted by a two-compartment perfusion model. Results: Mean perfusion values (+/- SD) derived from the MRI......Purpose: To validate a noninvasive quantitative MRI technique, the K-i perfusion method, for myocardial perfusion in humans using N-13-ammonia PET as a reference method. Materials and Methods: Ten healthy males (64 +/- 8 years) were examined with combined PET and MRI perfusion imaging at rest...... method at rest and at hyperemia were 80 +/- 20 and 183 +/- 56 mL/min/100 g, respectively. The same data for PET were 71 +/- 16 and 203 +/- 67 mL/min/100 g. A linear relationship was observed between MRI and PET-derived myocardial perfusion reserve for regional and global data. Linear regression...

  8. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); The Interuniversity Cardiology Institute of The Netherlands, Utrecht (Netherlands); El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Kroft, Lucia J. [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Younis, Imad Al [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Reiber, Johan H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical imaging systems B.V., Leiden (Netherlands); Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands)

    2013-08-15

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 {+-} 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS {>=}2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p < 0.001, and OR 1.07, 95 % CI 1.00-1.45, p = 0.032, respectively) after correcting for clinical variables and visually assessed significant stenosis. The addition of quantitatively assessed significant stenosis ({chi} {sup 2} = 20.7) and lesion length ({chi} {sup 2} = 26.0) to the clinical variables and the visual assessment ({chi} {sup 2} = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have

  9. Parallel imaging for first-pass myocardial perfusion.

    Science.gov (United States)

    Irwan, Roy; Lubbers, Daniël D; van der Vleuten, Pieter A; Kappert, Peter; Götte, Marco J W; Sijens, Paul E

    2007-06-01

    Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisition (GRAPPA), which are both applied to a gradient-echo sequence. Both methods were tested on 12 patients with coronary artery disease. The order of perfusion sequences was inverted in every other patient. Image acquisition was started during the administration of a contrast bolus followed by a 20-ml saline flush (3 ml/s), and the next perfusion was started at least 15 min thereafter using an identical bolus. An acceleration rate of 2 was used in both methods, and acquisition was performed during breath-holding. Significantly higher SNR, CNR and image quality were obtained with GRAPPA images than with TSENSE images. GRAPPA, however, did not yield a higher CNR when applied after the second bolus. GRAPPA perfusion imaging produced larger differences between subjects than did TSENSE. Compared to TSENSE, GRAPPA produced significantly better CNR on the first bolus. More consistent SNR and CNR were obtained from TSENSE images than from GRAPPA images, indicating that the diagnostic value of TSENSE may be better.

  10. Score cards for standardized comparison of myocardial perfusion imaging reports

    DEFF Research Database (Denmark)

    Jensen, Julie D; Hoff, Camilla; Bouchelouche, Kirsten

    Background: When optimizing scan protocols or comparing modalities in myocardial perfusion imaging, it is necessary to compare the current method to the new method This can be achieved by a comparison based on hard numbers such as MBF, summed rest and stress scores, total perfusion deficit etc....... However, what is of importance to the patient is the total evaluation of these scores and the weight and confidence ascribed to each by the reporting physician. We suggest a standardized method summarizing the observations and the confidence of the physician in simple scores. We tested the developed score...... cards in a pilotproject using a training scenario where 3 observers with varying experience (1 month, 5 months and 3 years, respectively) scored static rest/stress Rb-82 PET scans. Method: 10 patients with known ischemic heart disease were included. Using the 17-segment AHA cardiac model, each patient...

  11. Detection of extracardiac disease during Tl-201 myocardial perfusion study

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan H.; Lee, Myoung Hoon; Yoon, Seok Nam; Hwang, Kyung Hoon [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    2001-07-01

    It is important to observe extracardiac disease processes (ECD) during cardiac perfusion imaging for valuable information can be obtained at no extracost to patients. The aim of the study is to find out the frequency of ECD during Tl-201 stress myocardial perfusion imaging (TSMPI). Retrospective evaluation of 552 TSMPI was done. There were 229 males and 223 females reffered for evaluation of possible ischemic heart disease. Their ages range from 20 to 80 with mean age of 58.8 years. Three mCi (111 MBq) of 201 TlCl is used for adenosine or treadmil exercise testing and myocardial SPECT is performed utilizing low energy high resolution collimators and a triple-head camera ( MultiSPECT, Siemens medical systems, Inc., Hoffman Estate, III., USA). In addition to routine cardiac Tl-201 SPECT acquisition, included in the protocol is 1 min, anterior planar views in 128 128 matrix after stress and rest SPECT studies for evaluation of lung uptake and chamber size. Utilizing these views ECD is assessed. Five patients had focal increased activity suggesting tumor and 3 of 5 cases were confirmed as malignancy. The malignancies were thyroid cancer (Hurthle cell), lung cancer, and breast cancer. Benign lesions were autonomous thyroid nodule and pheochromocytoma. Other ECDs include pericardial effusion, pleural effusion, and paralyzed hemidiapharm.. Extracardiac disease processes such as benign or malignancy are easily detected during Tl-201 myocardial perfusion imaging using our acquisition protocol at no cost to the patients. This information could be life saving in some patients for early detection of clinically unsuspected malignancy.

  12. Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Runza, G. [Department of Radiology, University of Palermo (Italy)], E-mail: grunza@sirm.org; La Grutta, L.; Alaimo, V. [Department of Radiology, University of Palermo (Italy); Evola, S. [Department of Cardiology, University of Palermo (Italy); Lo Re, F.; Bartolotta, T.V. [Department of Radiology, University of Palermo (Italy); Cademartiri, F. [Department of Radiology and Cardiology, Erasmus Medical Center, Rotterdam (Netherlands); Department of Radiology and Cardiology, Cardiovascular CT Unit, University Hospital, Parma (Italy); Midiri, M. [Department of Radiology, University of Palermo (Italy)

    2007-10-15

    Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to scan the entire thorax visualizing the thoracic aorta, the pulmonary arteries, and the coronary arteries could provide a new approach to the triage of acute chest pain. The inherent advantage of MDCT with cardiac state-of-the-art capabilities is the rapid investigation of the main sources of acute chest pain with a high negative predictive value. Recent studies also reports an advantage in terms of costs. With current evidence, the selection of patients with acute chest pain candidates to MDCT should remain restricted to avoid unjustified risk of ionizing radiation.

  13. QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY

    Institute of Scientific and Technical Information of China (English)

    Lei Zhuang; Ming-xing Xie; Wei-juan Wang; Xiang-xin Yang; Tao Liu

    2006-01-01

    Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3 DE).Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD,n=14) or distal branch of the left circumflex artery (LCX,n=7).A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal's heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38. 9 to78.5 (mean±SD: 60.0±10.1)g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x).Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.

  14. 13N-ammonia PET/CT detection of myocardial perfusion abnormalities in Beagle dogs after local heart irradiation.

    Science.gov (United States)

    Song, Jianbo; Yan, Rui; Wu, Zhifang; Li, Jianguo; Yan, Min; Hao, Xinzhong; Liu, Jianzhong; Li, Sijin

    2016-12-01

    To determine the potential value of (13)N-ammonia positron emission tomography (PET)/computed tomography (CT) myocardial perfusion imaging (MPI) for detection of myocardial perfusion changes at early stage induced by radiation damage.

  15. Can preoperative myocardial perfusion scintigraphy predict changes in left ventricular perfusion and function after coronary artery bypass graft surgery?

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Johansen, Allan;

    2012-01-01

    OBJECTIVESWe wanted to evaluate whether preoperative myocardial perfusion scintigraphy (MPS) could predict changes in cardiac symptoms and postoperative myocardial perfusion and left ventricular function after coronary artery bypass grafting (CABG).METHODSNinety-two patients with stable angina......%. Before CABG, one patient had normal perfusion; in the rest of them the defects were classified as follows: reversible (60%), partly reversible (27%) and irreversible (12%). Following CABG, 33% had normal perfusion; in the rest the defects were reversible in 29%, partly reversible in 12% and irreversible...... in 26%. Left ventricular ejection fraction (LVEF), which was normal before operation in 45%, improved in 40% of all patients. The increase in LVEF was not related to the preoperative pattern of perfusion defects. Of 30 patients with normalized perfusion after CABG, 29 (97%) had reversible defects...

  16. Simulation evaluation of quantitative myocardial perfusion assessment from cardiac CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-03-01

    Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for clinical decisions and 2) low radiation doses for patient safety. This work developed a thorough dynamic CT simulation and several accepted blood flow estimation techniques to evaluate the performance of perfusion assessment across a range of acquisition and estimation scenarios. Cardiac CT acquisitions were simulated for a range of flow states (Flow = 0.5, 1, 2, 3 ml/g/min, cardiac output = 3,5,8 L/min). CT acquisitions were simulated with a validated CT simulator incorporating polyenergetic data acquisition and realistic x-ray flux levels for dynamic acquisitions with a range of scenarios including 1, 2, 3 sec sampling for 30 sec with 25, 70, 140 mAs. Images were generated using conventional image reconstruction with additional image-based beam hardening correction to account for iodine content. Time attenuation curves were extracted for multiple regions around the myocardium and used to estimate flow. In total, 2,700 independent realizations of dynamic sequences were generated and multiple MBF estimation methods were applied to each of these. Evaluation of quantitative kinetic modeling yielded blood flow estimates with an root mean square error (RMSE) of ~0.6 ml/g/min averaged across multiple scenarios. Semi-quantitative modeling and qualitative static imaging resulted in significantly more error (RMSE = ~1.2 and ~1.2 ml/min/g respectively). For quantitative methods, dose reduction through reduced temporal sampling or reduced tube current had comparable impact on the MBF estimate fidelity. On average, half dose acquisitions increased the RMSE of estimates by only 18% suggesting that substantial dose reductions can be employed in the context of quantitative myocardial

  17. Comparison of non-attenuation corrected and attenuation corrected myocardial perfusion SPE

    Directory of Open Access Journals (Sweden)

    Hasan Raza

    2016-09-01

    Conclusion: This study demonstrates that CT based attenuation corrected Tc-99mm sestamibi SPECT myocardial perfusion imaging significantly improved the specificity of the RCA territory compared with non-attenuation corrected Tc-99mm sestamibi SPECT myocardial perfusion imaging in both genders irrespective of BMI.

  18. Effects of permanent dual chamber pacing on myocardial perfusion in symptomatic hypertrophic cardiomyopathy

    NARCIS (Netherlands)

    Posma, JL; Blanksma, PK; VanderWall, EE; Vaalburg, W; Crijns, HJGM; Lie, KI

    1996-01-01

    Objective-Angina and the presence of myocardial ischaemia are common in hypertrophic cardiomyopathy. Dual chamber pacing results in clinical improvement in these patients. This study evaluates the effects of permanent dual chamber pacing on absolute regional myocardial perfusion and perfusion

  19. When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?

    DEFF Research Database (Denmark)

    Johansen, Allan; Lomsky, Milan; Gerke, Oke

    2013-01-01

    Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal...

  20. Effects of permanent dual chamber pacing on myocardial perfusion in symptomatic hypertrophic cardiomyopathy

    NARCIS (Netherlands)

    Posma, JL; Blanksma, PK; VanderWall, EE; Vaalburg, W; Crijns, HJGM; Lie, KI

    1996-01-01

    Objective-Angina and the presence of myocardial ischaemia are common in hypertrophic cardiomyopathy. Dual chamber pacing results in clinical improvement in these patients. This study evaluates the effects of permanent dual chamber pacing on absolute regional myocardial perfusion and perfusion reserv

  1. Relation of impaired Thrombolysis In Myocardial Infarction myocardial perfusion grades to residual thrombus following the restoration of epicardial patency in ST-elevation myocardial infarction.

    Science.gov (United States)

    Kirtane, Ajay J; Weisbord, Aaron; Karmpaliotis, Dimitrios; Murphy, Sabina A; Giugliano, Robert P; Cannon, Christopher P; Antman, Elliott M; Ohman, E Magnus; Roe, Matthew T; Braunwald, Eugene; Gibson, C Michael

    2005-01-15

    Clinical and angiographic data were analyzed from 929 patients who had ST-elevation myocardial infarction and open epicardial arteries after fibrinolytic therapy. Residual angiographically evident thrombus was associated with more frequent Thrombolysis In Myocardial Infarction (TIMI) grade 2 flow (33.6% vs 26.8%, p = 0.03), higher corrected TIMI frame counts (34 vs 31 frames, p = 0.0003), and lower TIMI myocardial perfusion grades (43.0% vs 32.0% TIMI myocardial perfusion grades 0/1, p = 0.001) among all patients and among patients who had TIMI grade 3 flow (33.5% vs 26.0% TIMI myocardial perfusion grades 0/1, p = 0.043). In multivariate analyses, angiographically evident thrombus was associated with higher corrected TIMI frame counts and worsened myocardial perfusion independent of clinical and angiographic covariates, including TIMI grade 3 flow.

  2. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  3. A study of partial volume effect on SPECT imaging using myocardial phantom. With HCM (ASH) model myocardial phantom

    Energy Technology Data Exchange (ETDEWEB)

    Onoguchi, Masahisa [Kanazawa Univ. (Japan). School of Medicine

    1997-05-01

    In order to evaluate simultaneously both myocardial perfusion and regional wall motion using ECG-gated myocardial SPECT imaging, correction for the partial volume effect (PVE) should be performed. For the quantitative analysis of myocardial SPECT imaging in patients with hypertrophic cardiomyopathy (HCM), we formed a new phantom simulating HCM with various septal wall thicknesses and estimated PVE using the recovery coefficient (RC). The value of RC in all phantoms increased with increasing thickness of the septal wall reaching a plateau at 25 mm for the cylindrical phantom and 25 mm for the Ep-phantom. Compared with the RC value, the PMMA-phantom had little influence on PVE. Therefore, our results suggested that the count in the septal wall could be underestimated if PVE was corrected by the value obtained for the cylindrical phantom. In conclusion, our new phantom simulating HCM was useful in assessing PVE in the hypertrophic septal wall. (author)

  4. Adiposity Is Associated with Gender-Specific Reductions in Left Ventricular Myocardial Perfusion during Dobutamine Stress.

    Directory of Open Access Journals (Sweden)

    Michael E Hall

    Full Text Available Obesity and visceral adiposity are increasingly recognized risk factors for cardiovascular disease. Visceral fat may reduce myocardial perfusion by impairing vascular endothelial function. Women experience more anginal symptoms compared to men despite less severe coronary artery stenosis, as assessed by angiography. Women and men have different fat storage patterns which may account for the observed differences in cardiovascular disease. Therefore, our objective was to evaluate the relationship between visceral adipose tissue distributions and myocardial perfusion in men and women.Visceral and subcutaneous fat distributions and myocardial perfusion were measured in 69 men and women without coronary artery disease using magnetic resonance imaging techniques. Myocardial perfusion index was quantified after first-pass perfusion with gadolinium contrast at peak dose dobutamine stress.We observed inverse relationships between female gender (r = -0.35, p = 0.003, pericardial fat (r = -0.36, p = 0.03, intraperitoneal fat (r = -0.37, p = 0.001, and retroperitoneal fat (r = -0.36, p = 0.002 and myocardial perfusion index. Visceral fat depots were not associated with reduced myocardial perfusion at peak dose dobutamine in men. However, in women, BMI (r = -0.33, p = 0.04, pericardial fat (r = -0.53, p = 0.02, subcutaneous fat (r = -0.39, p = 0.01 and intraperitoneal fat (r = -0.30, p = 0.05 were associated with reduced myocardial perfusion during dobutamine stress.Higher visceral fat volumes are associated with reduced left ventricular myocardial perfusion at peak dose dobutamine stress in women but not in men. These findings suggest that visceral fat may contribute to abnormal microcirculatory coronary artery perfusion syndromes, explaining why some women exhibit more anginal symptoms despite typically lower grade epicardial coronary artery stenoses than men.

  5. Absolute Versus Relative Myocardial Blood Flow by Dynamic CT Myocardial Perfusion Imaging in Patients With Anatomic Coronary Artery Disease

    NARCIS (Netherlands)

    Wichmann, Julian L.; Meinel, Felix G.; Schoepf, U. Joseph; Lo, Gladys G.; Choe, Yeon Hyeon; Wang, Yining; Vliegenthart, Rozemarijn; Varga-Szemes, Akos; Muscogiuri, Giuseppe; Cannao, Paola M.; De Cecco, Carlo N.

    2015-01-01

    OBJECTIVE. The purpose of this study was to evaluate differences in the diagnostic accuracy of absolute and relative territorial myocardial blood flow (MBF) derived from stress dynamic CT myocardial perfusion imaging (MPI) for the detection of significant coronary artery stenosis. MATERIALS AND METH

  6. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    NARCIS (Netherlands)

    A. Coenen (Adriaan); M. Lubbers (Marisa); A. Kurata (Akira); A.K. Kono (Atsushi K.); A. Dedic (Admir); R.G. Chelu (Raluca Gabriela); M.L. Dijkshoorn (Marcel); Rossi, A. (Alexia); R.J.M. van Geuns (Robert Jan); K. Nieman (Koen)

    2016-01-01

    textabstractObjectives: To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Methods: Subjects with suspected or known coro

  7. Perfusion vector - a new method to quantify myocardial perfusion scintigraphy images: a simulation study with validation in patients

    DEFF Research Database (Denmark)

    Minarik, David; Senneby, Martin; Wollmer, Per

    2015-01-01

    Background The interpretation of myocardial perfusion scintigraphy (MPS) largely relies on visual assessment by the physician of the localization and extent of a perfusion defect. The aim of this study was to introduce the concept of the perfusion vector as a new objective quantitative method...... for further assisting the visual interpretation and to test the concept using simulated MPS images as well as patients. Methods The perfusion vector is based on calculating the difference between the anatomical centroid and the perfusion center of gravity of the left ventricle. Simulated MPS images were.......001) but not for patients with infarction. The correlation between the defect size and stress vector magnitude was also found to be significant (p concept of the perfusion vector introduced in this study is shown to have potential in assisting the visual interpretation in MPS studies. Further...

  8. Usefulness of myocardial perfusion imaging with exercise testing in children.

    Science.gov (United States)

    Robinson, Brad; Goudie, Brett; Remmert, Jenna; Gidding, Samuel S

    2012-10-01

    Myocardial perfusion imaging (MPI) provides additional clinical information on children with cardiac disease but will not benefit children with chest pain and normal cardiac studies. This study reviewed all technetium-99 m ((99m)Tc) sestamibi stress MPI studies between 2004 and 2010 performed in association with graded exercise testing (86% with bicycle ergometer, 14% with treadmill). A positive test was defined as a perfusion defect or abnormal ventricular function response. Clinical records were reviewed, including follow-up assessment to determine accuracy of MPI interpretation. False-positive and false-negative rates were recorded. A total of 197 patients (mean age, 13.4 ± 3.6 years, 70% male) underwent 218 MPI studies. Group A had 42 patients (43 studies) with isolated chest pain and normal studies. Of the 43 studies, 39 had negative results, and 4 had false-positive results. Group B had 155 patients (175 studies) with known or suspected cardiac disease, and 39 tests (33 patients) had positive results. Whereas 32 studies were considered true-positive, 7 were false-positive. There was one false-negative test. According to the findings, (99m)Tc sestamibi MPI studies are clinically useful but not perfect tests in the setting of known or suspected cardiac disease based on clinical evaluation, electrocardiography (ECG), or echocardiography. Children who had isolated chest pain with a normal ECG and echocardiogram often have false-positive studies.

  9. AUTOMATED AGATSTON SCORE COMPUTATION IN A LARGE DATASET OF NON ECG-GATED CHEST COMPUTED TOMOGRAPHY.

    Science.gov (United States)

    González, Germán; Washko, George R; Estépar, Raúl San José

    2016-04-01

    The Agatston score, computed from ECG-gated computed tomography (CT), is a well established metric of coronary artery disease. It has been recently shown that the Agatston score computed from chest CT (non ECG-gated) studies is highly correlated with the Agatston score computed from cardiac CT scans. In this work we present an automated method to compute the Agatston score from chest CT images. Coronary arteries calcifications (CACs) are defined as voxels contained within the coronary arteries with a value greater or equal to 130 Hounsfield Units (HU). CACs are automatically detected in chest CT studies by locating the heart, generating a region of interest around it, thresholding the image in such region and applying a set of rules to discriminate CACs from calcifications in the main vessels or from metallic implants. We evaluate the methodology in a large cohort of 1500 patients for whom manual reference standard is available. Our results show that the Pearson correlation coefficient between manual and automated Agatston score is ρ = 0.86 (p < 0.0001).

  10. Imaging the pericardium: appearances on ECG-gated 64-detector row cardiac computed tomography

    Science.gov (United States)

    O'Leary, S M; Williams, P L; Williams, M P; Edwards, A J; Roobottom, C A; Morgan-Hughes, G J; Manghat, N E

    2010-01-01

    Multidetector row computed tomography (MDCT) with its high spatial and temporal resolution has now become an established and complementary method for cardiac imaging. It can now be used reliably to exclude significant coronary artery disease and delineate complex coronary artery anomalies, and has become a valuable problem-solving tool. Our experience with MDCT imaging suggests that it is clinically useful for imaging the pericardium. It is important to be aware of the normal anatomy of the pericardium and not mistake normal variations for pathology. The pericardial recesses are visible in up to 44% of non-electrocardiogram (ECG)-gated MDCT images. Abnormalities of the pericardium can now be identified with increasing certainty on 64-detector row CT; they may be the key to diagnosis and therefore must not be overlooked. This educational review of the pericardium will cover different imaging techniques, with a significant emphasis on MDCT. We have a large research and clinical experience of ECG-gated cardiac CT and will demonstrate examples of pericardial recesses, their variations and a wide variety of pericardial abnormalities and systemic conditions affecting the pericardium. We give a brief relevant background of the conditions and reinforce the key imaging features. We aim to provide a pictorial demonstration of the wide variety of abnormalities of the pericardium and the pitfalls in the diagnosis of pericardial disease. PMID:20197434

  11. Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects

    Institute of Scientific and Technical Information of China (English)

    CHEN Li-xin 陈立新; YANG Ying 杨颖; FEI Hong-wen 费洪文; WANG Liang-yu 王良玉; WANG Xin-fang 王新房; Navin C Nanda; Andrew P Miller; XIE Ming-xing 谢明星; ZHUANG Lei 庄磊; YANG Ya 杨娅; WANG Jing 王静; HUANG Run-qing 黄润青

    2004-01-01

    Background Both real-time three-dimensional echocardiography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects.Methods Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n=6) or distal branch of the left circumflex artery (LCX, n=7) under general anaesthesia. Three to four ml of a perfluoropropane (C3F8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and right coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals' hearts were used as controls.Results Left ventricular (LV) mass determined by RT3DE ranged 36.7-68.9 g [mean, (54.6±9.6) g] before coronary artery ligation, and correlated highly (r=0.99) with in vitro measurement of LV mass [range, 38.9-71.1 g; mean, (55.6±9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7-68.9 g; mean, (51.3±12.5) g. Or range, 38.9-71.1 g; mean, (53.7±12.3) g, respectively] and under-perfused mass [range, 0-21.4 g; mean, (12.0±6.9) g. Or range, 0-19.8 g; mean, (10.8±6.3) g, respectively] after the LAD ligation (P>0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1-65.4 g; mean, (57.5±5.9) g. Or range, 51.5-65.8 g; mean, (57.3±6.4) g, respectively] and under-perfused mass [range, 0-25.6 g; mean, (13.3±9.6) g. Or range, 0-22.7 g; mean, (12.8±8.1) g, respectively] after the LCX ligation (P>0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9-68.6 g [mean, (54.8±10.0) g] and there was

  12. Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul, E-mail: paul.stolzmann@usz.ch [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Goetti, Robert; Baumueller, Stephan [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Plass, Andre; Falk, Volkmar [Clinic for Cardiovascular Surgery, University Hospital Zurich (Switzerland); Scheffel, Hans; Feuchtner, Gudrun; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Alkadhi, Hatem [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland); Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Leschka, Sebastian [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2011-07-15

    Objective: To compare, in patients with suspicion of coronary artery disease (CAD) and low heart rates, image quality, diagnostic performance, and radiation dose values of prospectively and retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (CTCA) for the diagnosis of significant coronary stenoses. Materials and methods: Two-hundred consecutive patients with heart rates {<=}70 bpm were retrospectively enrolled; 100 patients undergoing prospectively ECG-gated CTCA (group 1) and 100 patients undergoing retrospectively-gated CTCA (group 2). Coronary artery segments were assessed for image quality and significant luminal diameter narrowing. Sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV), and accuracy of both CTCA groups were determined using conventional catheter angiography (CCA) as reference standard. Radiation dose values were calculated. Results: Both groups were comparable regarding gender, body weight, cardiovascular risk profile, severity of CAD, mean heart rate, heart rate variability, and Agatston score (all p > 0.05). There was no significant difference in the rate of non-assessable coronary segments between group 1 (1.6%, 24/1404) and group 2 (1.4%, 19/1385; p = 0.77); non-diagnostic image quality was significantly (p < 0.001) more often attributed to stair step artifacts in group 1. Segment-based sensitivity, specificity, PPV, NPV, and accuracy were 98%, 98%, 88%, 100%, and 100% among group 1; 96%, 99%, 90%, 100%, and 98% among group 2, respectively. Parameters of diagnostic performance were similar (all p > 0.05). Mean effective radiation dose of prospectively ECG-gated CTCA (2.2 {+-} 0.4 mSv) was significantly (p < 0.0001) smaller than that of retrospectively ECG-gated CTCA (8.1 {+-} 0.6 mSv). Conclusion: Prospectively ECG-gated CTCA yields similar image quality, performs as accurately as retrospectively ECG-gated CTCA in patients having heart rates {<=}70 bpm

  13. The Relationship Between Some Complete Blood Count Parameters and Myocardial Perfusion: A Scintigraphic Approach.

    Science.gov (United States)

    Ozdemir, Semra; Barutcu, Ahmet; Gazi, Emine; Tan, Yusuf Ziya; Turkon, Hakan

    2015-01-01

    Recent studies have shown that there is a relationship between some inflammatory and biochemical markers derived from complete blood count (CBC) such as neutrophil/lymphocyte (N/L) ratio, platelet/lymphocyte (P/L) ratio, platelet distribution width (PDW), red blood cell distribution width (RDW), and coronary artery disease (CAD). The aim of this study was to determine N/L ratio, P/L ratio, PDW values, and RDW values, which are associated with myocardial perfusion in patients diagnosed with CAD. This study included 262 patients (149 with myocardial ischemia/infarction and 113 with normal myocardial perfusion) undergoing myocardial perfusion scintigraphy (MPS) with CBC within 90 days of MPS. Myocardial perfusion parameters such as summed stress score and summed difference score (SDS) were compared with N/L ratio, P/L ratio, PDW values, and RDW values. Neutrophil counts and N/L ratios were significantly higher in patients diagnosed with myocardial ischemia and/or infarct. However, there was no statistically significant relationship between myocardial perfusion abnormalities and P/L ratio, PDW values, and RDW values. This study showed that N/L ratio is related to myocardial ischemia/infarction and correlated to left ventricular ejection fraction (LVEF).

  14. A decision support system for stress only myocardial perfusion scintigraphy may save unnecessary rest studies

    DEFF Research Database (Denmark)

    Tägil, K; Jakobsson, D; Lomsky, M

    2013-01-01

    The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS)....

  15. Prognostic value of dobutamine-atropine stress myocardial perfusion imaging in patients with diabetes

    NARCIS (Netherlands)

    A.F.L. Schinkel (Arend); A. Elhendy (Abdou); J.J. Bax (Jeroen); E.C. Vourvouri (Eleni); F. Sozzi (Fabiola); R. Valkema (Roelf); D. Poldermans (Don); J.R.T.C. Roelandt (Jos); R.T. van Domburg (Ron)

    2002-01-01

    textabstractOBJECTIVE: Exercise tolerance in patients with diabetes is frequently impaired due to noncardiac disease such as claudication and polyneuropathy. This study assesses the prognostic value of dobutamine stress myocardial perfusion imaging in patients with diabetes. RESEAR

  16. Development of coronary vasospasm during adenosine-stress myocardial perfusion CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jeong Gu; Choi, Seong Hoon; Kang, Byeong Seong; Bang, Min Aeo; Kwon, Woon Jeong [Dept. of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2015-06-15

    Adenosine is a short-acting coronary vasodilator, and it is widely used during pharmacological stress myocardial perfusion imaging. It has a well-established safety profile, and most of its side effects are known to be mild and transient. Until now, coronary vasospasm has been rarely reported as a side effect of adenosine during or after adenosine stress test. This study reports a case of coronary vasospasm which was documented on stress myocardial perfusion CT imaging during adenosine stress test.

  17. A Unifying model of perfusion and motion applied to reconstruction of sparsely sampled free-breathing myocardial perfusion MRI

    DEFF Research Database (Denmark)

    Pedersen, Henrik; Ólafsdóttir, Hildur; Larsen, Rasmus

    2010-01-01

    The clinical potential of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is currently limited by respiratory induced motion of the heart. This paper presents a unifying model of perfusion and motion in which respiratory motion becomes an integral part of myocardial perfusion...... quantification. Hence, the need for tedious manual motion correction prior to perfusion quantification is avoided. In addition, we demonstrate that the proposed framework facilitates the process of reconstructing DCEMRI from sparsely sampled data in the presence of respiratory motion. The paper focuses primarily...

  18. Rest perfusion abnormalities in hypertrophic cardiomyopathy: correlation with myocardial fibrosis and risk factors for sudden cardiac death.

    Science.gov (United States)

    Chiribiri, A; Leuzzi, S; Conte, M R; Bongioanni, S; Bratis, K; Olivotti, L; De Rosa, C; Lardone, E; Di Donna, P; Villa, A D M; Cesarani, F; Nagel, E; Gaita, F; Bonamini, R

    2015-05-01

    To measure the prevalence of abnormal rest perfusion in a population of consecutive patients with known hypertrophic cardiomyopathy (HCM) referred for cardiovascular MRI (CMR), and to assess any associations between abnormal rest perfusion and the presence, pattern, and severity of myocardial scar and the presence of risk factors for sudden death. Eighty consecutive patients with known HCM referred for CMR underwent functional imaging, rest first-pass perfusion, and late gadolinium enhancement (LGE). Thirty percent of the patients had abnormal rest perfusion, all of them corresponding to areas of mid-myocardial LGE and to a higher degree of segmental hypertrophy. Rest perfusion abnormalities correlated with more extensive and confluent LGE. The subgroup of patients with myocardial fibrosis and rest perfusion abnormalities (fibrosis+/perfusion+) had more than twice the incidence of episodes of non-sustained ventricular tachycardia on Holter monitoring in comparison to patients with myocardial fibrosis and normal rest perfusion (fibrosis+/perfusion-) and patients with no fibrosis and normal rest perfusion (fibrosis-/perfusion-). First-pass perfusion CMR identifies abnormal rest perfusion in a significant proportion of patients with HCM. These abnormalities are associated with the presence and distribution of myocardial scar and the degree of hypertrophy. Rest perfusion abnormalities identify patients with increased incidence of episodes of non-sustained ventricular tachycardia on Holter monitoring, independently from the presence of myocardial fibrosis. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Myocardial perfusion imaging determination using an appropriate use smartphone application.

    Science.gov (United States)

    Mahajan, Ashish; Bal, Susan; Hahn, Harvey

    2015-02-01

    Inappropriate cardiac imaging has been a significant cost concern and cause of radiation burden to patients. To assess if a smartphone application (app) based on 2009 Appropriate Use Criteria (AUC) for Cardiac Radionuclide Imaging published by American College of Cardiology would be feasible at the point of order. We evaluated stress myocardial perfusion imaging (MPI) (N = 403) (mean age = 62.23 years; 47.89% males) over a 4 month period using a smartphone app to determine whether the study ordered was Appropriate, Inappropriate, or Uncertain per 2009 AUC. We also monitored the time needed to use the app to determine the level of appropriateness of each stress MPI. The results of the stress MPI were noted. Of the 403 stress MPIs evaluated, 267 (66.25%) were noted to be Appropriate, 118 (29.28%) were Inappropriate, and 13 (3.23%) were Uncertain, per AUC; 5 (1.25%) remained unclassified. Average time needed to use the app to assess each stress MPI for appropriateness was noted to be 44 (±9) seconds. Non-teaching physicians ordered 70 (38.89%) inappropriate stress MPIs as compared to 20 (23.53%) ordered by physicians on resident teaching service, and 28 (23.33%) by cardiologists (P = .0045). Among inappropriately ordered stress MPIs, 87 (42.65%) were ordered in females as compared to 31 (17.13%) in males (P stress MPIs among appropriately ordered were abnormal (reversible ischemia or fixed perfusion defect) as compared to 15 (12.17%) among inappropriately ordered stress MPIs (P = .0032). A free and convenient smartphone app provides an easy-to-use tool to assist physicians in determining the level of appropriateness of stress MPI in a time- and cost-effective manner at the point of order. The smartphone app may have potential to promote the usage of the AUC and possibly aid reduction of healthcare cost and ionizing radiation burden.

  20. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf;

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim...

  1. Clinical investigation of large perfusion defect cases with {sup 201}Tl exercise myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Morota, Motoi; Kobayashi, Yasuhiko [Tokyo Medical Coll. (Japan)

    1999-02-01

    We investigated retrospectively the clinical significance of large perfusion defect on {sup 201}Thallium myocardial scintigraphy from the records of 833 patients during the past 3 years from 1991 to 1994. The patients were divided into 3 groups according to the extent of perfusion defect; cases with normal perfusion (n=561), with small perfusion defect (n=211) and with large perfusion defect (n=61). We found that the proportions of cases with large perfusion defect was significantly larger than that of cases with small perfusion defect in myocardial disease (MD; hypertrophic cardiomyopathy, dilated cardiomyopathy, and post myocarditis combined) (P<0.001). Analyzing patients with ischemic heart disease (IHD; angina pectoris and myocardial infarction) according to the severity of coronary artery lesion, the proportion of cases with large perfusion defect was significantly larger than that of cases with small perfusion defect in 3 vessel disease (P<0.001). Incidence of diabetes mellitus was significantly higher in patients with IHD than in those with MD in large perfusion defect group (P<0.01). As for symptoms in large perfusion defect group, the incidences of chest pain, chest oppression, and chest discomfort were significantly higher in patients with IHD than in those with MD (P<0.001), whereas the incidences of palpitation and shortness of breath were significantly higher in patients with MD (P<0.001). These results suggest that IHD with multiple artery lesions and MD underlie large perfusion defect on {sup 201}Thallium myocardial scintigraphy and that complication of diabetes mellitus and clinical symptoms may be useful in differentiating IHD from MD. (author)

  2. Neonate Aortic Stenosis: Importance of Myocardial Perfusion in Prognosis

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Santos

    2002-09-01

    Full Text Available OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2±1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure. Five of the other 7 patients underwent a new procedure and 2 required surgery.CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.

  3. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  4. Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion

    Directory of Open Access Journals (Sweden)

    Gert Jan Pelgrim

    2015-01-01

    Full Text Available Objective. To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experiment. Stenosis was induced in the circumflex artery, controlled by a fractional flow reserve (FFR pressure wire. CT-derived myocardial perfusion parameters were analysed at FFR of 1 to 0.10/0.0. Results. CT images did not show major artefacts due to interference of the model setup. The pacemaker-induced heart rhythm was generally stable at 70 beats per minute. During most of the experiment, blood flow was 0.9–1.0 L/min, and arterial pressure varied between 80 and 95 mm/Hg. Blood flow decreased and arterial pressure increased by approximately 10% after inducing a stenosis with FFR ≤ 0.50. Dynamic perfusion scanning was possible across the range of stenosis grades. Perfusion parameters of circumflex-perfused myocardial segments were affected at increasing stenosis grades. Conclusion. An adapted Langendorff porcine heart model is feasible in a CT environment. This model provides control over physiological parameters and may allow in-depth validation of quantitative CT perfusion techniques.

  5. Added value of attenuation-corrected myocardial perfusion scintigraphy in a patient with dextrocardia

    NARCIS (Netherlands)

    Slart, RHJA; De Boer, J; Jager, PL; Piers, DA

    2002-01-01

    A 52-year-old woman with dextrocardia was evaluated for chest pain. To exclude myocardial ischemia, she underwent a 2-day rest and bicycle stress myocardial perfusion study with 600 MBq (16 mCi) Tc-99m sestamibi. The rotational direction of the perpendicularly positioned camera heads was fixed and a

  6. Measurement of myocardial perfusion and infarction size using computer-aided diagnosis system for myocardial contrast echocardiography.

    Science.gov (United States)

    Du, Guo-Qing; Xue, Jing-Yi; Guo, Yanhui; Chen, Shuang; Du, Pei; Wu, Yan; Wang, Yu-Hang; Zong, Li-Qiu; Tian, Jia-Wei

    2015-09-01

    Proper evaluation of myocardial microvascular perfusion and assessment of infarct size is critical for clinicians. We have developed a novel computer-aided diagnosis (CAD) approach for myocardial contrast echocardiography (MCE) to measure myocardial perfusion and infarct size. Rabbits underwent 15 min of coronary occlusion followed by reperfusion (group I, n = 15) or 60 min of coronary occlusion followed by reperfusion (group II, n = 15). Myocardial contrast echocardiography was performed before and 7 d after ischemia/reperfusion, and images were analyzed with the CAD system on the basis of eliminating particle swarm optimization clustering analysis. The myocardium was quickly and accurately detected using contrast-enhanced images, myocardial perfusion was quantitatively calibrated and a color-coded map calibrated by contrast intensity and automatically produced by the CAD system was used to outline the infarction region. Calibrated contrast intensity was significantly lower in infarct regions than in non-infarct regions, allowing differentiation of abnormal and normal myocardial perfusion. Receiver operating characteristic curve analysis documented that -54-pixel contrast intensity was an optimal cutoff point for the identification of infarcted myocardium with a sensitivity of 95.45% and specificity of 87.50%. Infarct sizes obtained using myocardial perfusion defect analysis of original contrast images and the contrast intensity-based color-coded map in computerized images were compared with infarct sizes measured using triphenyltetrazolium chloride staining. Use of the proposed CAD approach provided observers with more information. The infarct sizes obtained with myocardial perfusion defect analysis, the contrast intensity-based color-coded map and triphenyltetrazolium chloride staining were 23.72 ± 8.41%, 21.77 ± 7.8% and 18.21 ± 4.40% (% left ventricle) respectively (p > 0.05), indicating that computerized myocardial contrast echocardiography can

  7. Applicability of the Appropriate use Criteria for Myocardial Perfusion Scintigraphy

    Directory of Open Access Journals (Sweden)

    Anderson de Oliveira

    2014-11-01

    Full Text Available Background: Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC e American Society of Nuclear Cardiology (ASNC to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. Objective: To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. Methods: We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Results: Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3% studies were performed in men and 75 (20.4% were internee. To ACC 2005, 255 (69.5% were considered appropriate indication and 13 (3.5% inappropriate. With ACC 2009, 249 (67.8% were considered appropriate indications and 13 (5.2% inappropriate. Conclusions: We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results.

  8. Applicability of the Appropriate use Criteria for Myocardial Perfusion Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Anderson de [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Comissão Nacional de Energia Nuclear - CNEN (Brazil); Rezende, Maria Fernanda [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Corrêa, Renato; Mousinho, Rodrigo [Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Azevedo, Jader Cunha [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Miranda, Sandra Marina; Oliveira, Aline Ribeiro [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Gutterres, Ricardo Fraga [Comissão Nacional de Energia Nuclear - CNEN (Brazil); Mesquita, Evandro Tinoco; Mesquita, Cláudio Tinoco [Universidade Federal Fluminense - UFF, Niterói, RJ (Brazil); Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil)

    2014-11-15

    Appropriateness Criteria for nuclear imaging exams were created by American College of Cardiology (ACC) e American Society of Nuclear Cardiology (ASNC) to allow the rational use of tests. Little is known whether these criteria have been followed in clinical practice. To evaluate whether the medical applications of myocardial perfusion scintigraphy (MPS) in a private nuclear medicine service of a tertiary cardiology hospital were suitable to the criteria of indications proposed by the American medical societies in 2005 and 2009 and compare the level of indication of both. We included records of 383 patients that underwent MPS, November 2008 up to February 2009. Demographic characteristics, patient's origin, coronary risk factors, time of medical graduation and appropriateness criteria of medical applications were studied. The criteria were evaluated by two independent physicians and, in doubtful cases, defined by a medical expert in MPS. Mean age was 65 ± 12 years. Of the 367 records reviewed, 236 (64.3%) studies were performed in men and 75 (20.4%) were internee. To ACC 2005, 255 (69.5%) were considered appropriate indication and 13 (3.5%) inappropriate. With ACC 2009, 249 (67.8%) were considered appropriate indications and 13 (5.2%) inappropriate. We observed a high rate of adequacy of medical indications for MPS. Compared to the 2005 version, 2009 did not change the results.

  9. Stress-first single photon emission computed myocardial perfusion imaging

    Science.gov (United States)

    Aquino, C I; Scarano, M; Squame, F; Casaburi, G; Nori, S L; Pace, L

    2016-01-01

    Background Myocardial perfusion imaging (MPI) with single photon emission tomography (SPET) is widely used in coronary artery disease evaluation. Recently major dosimetric concerns have arisen. The aim of this study was to evaluate if a pre-test scoring system could predict the results of stress SPET MPI, thus avoiding two radionuclide injections. Methods All consecutive patients (n=309) undergoing SPET MPI during the first 6 months of 2014 constituted the study group. The scoring system is based on these characteristics: age >65 years (1 point), diabetes (2 points), typical chest pain (2 points), congestive heart failure (3 points), abnormal ECG (4 points), male gender (4 points), and documented previous CAD (5 points). The patients were divided on the basis of the prediction score into 3 classes of risk for an abnormal stress-first protocol. Results An abnormal stress SPET MPI was present in 7/31 patients (23%) with a low risk score, in 24/90 (27%) with an intermediate score risk, and in 124/188 (66%) with an high score risk. ROC curve analysis showed good prediction of abnormal stress MPI. Conclusions Our results suggest an appropriate use of a pre-test clinical prediction formula of abnormal stress MPI in a routine clinical setting. PMID:27896227

  10. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    Science.gov (United States)

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight cerebro-myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro-myocardial perfusion and possibly more versatile.

  11. Prevalence and clinical significance of incidental cardiac findings in non-ECG-gated chest CT scans; Praevalenz und klinische Bedeutung inzidenteller Herzbefunde im nicht EKG-getriggerten Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Quentin, M.; Kroepil, P.; Lanzman, R.S.; Blondin, D.; Miese, F.; Scherer, A. [Heinrich-Heine-Universitaet Duesseldorf, Institut fuer Radiologie, Duesseldorf (Germany); Steiner, S. [Klinikum der Heinrich-Heine-Universitaet Duesseldorf, Klinik fuer Kardiologie, Pneumologie und Angiologie, Duesseldorf (Germany); Choy, G.; Abbara, S. [Massachusetts General Hospital, Harvard Medical School, Cardiovascular Imaging Section, Boston (United States)

    2011-01-15

    The purpose of this study was to evaluate the prevalence and clinical significance of incidental cardiac findings in non-ECG-gated chest CT. Non-ECG-gated chest CT examinations of 300 patients were retrospectively analyzed for incidental cardiac findings. Subsequently, these findings were evaluated for their clinical relevance by a cardiologist. A total of 107 out of 300 examined patients had 174 incidental cardiac findings including coronary calcification (90), aortic/mitral valve calcification (42), iatrogenic changes (23), pericardial effusion (6), dilatation of the heart (4), myocardial changes (3), thrombus in the left ventricle (2), constrictive pericarditis (2) and atrial myxoma (1). Of the cardiac findings 51% were described in the written report and in 53 out of the 107 patients the cardiac findings were unknown. Newly detected incidental findings from 8 patients were rated as clinically significant: pericardial effusion (4), constrictive pericarditis (1), thrombus in the left ventricle (1), atrial myxoma (1) and dilatation of the heart (1). Incidental cardiac findings are frequent in non-ECG-gated chest CT and may have a high clinical relevance. (orig.) [German] Ziel dieser Studie war es, die Praevalenz und klinische Bedeutung inzidenteller Herzbefunde im nicht EKG-getriggerten Thorax-CT ohne primaer kardiale Fragestellung zu evaluieren. Dreihundert nicht EKG-getriggerte Thorax-CT-Untersuchungen wurden retrospektiv bzgl. inzidenteller Herzbefunde analysiert. Die klinische Bedeutung wurde von einem Kardiologen bewertet. Von 300 Patienten hatten 107 insgesamt 174 Herzbefunde: Koronarsklerose (90), Aorten-/Mitralklappenverkalkung (42), iatrogene Veraenderungen (23), Perikarderguss (6), Herzvergroesserung (4), Myokardpathologien (3), Perikardverkalkungen (2), Thrombus im linken Ventrikel (2) und Myxom (1). Im radiologischen Bericht wurden 51% aller Herzbefunde beschrieben. Bei 53 der 107 Patienten mit Herzbefund waren diese klinisch nicht bekannt. Als

  12. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2004-07-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP.

  13. Early and Delayed Myocardial Enhancement in Myocardial Infarction Using Two-Phase Contrast-Enhanced Multidetector-Row CT

    Science.gov (United States)

    Kim, Young-Whan; Han, Seong-Wook; Seo, Joon-Beom

    2007-01-01

    Objective The purpose of this study was to describe the myocardial enhancement patterns in patients with myocardial infarction using two-phase contrast-enhanced multidetector-row computed tomography (MDCT). Materials and Methods Twenty-three patients with clinically proven myocardial infarction (17 acute myocardial infarction [AMI] and 6 chronic myocardial infarction [CMI]) were examined with two-phase contrast-enhanced ECG-gated MDCT. The presence, location, and patterns of myocardial enhancement on two-phase MDCT images were compared with infarcted myocardial territories determined by using electrocardiogram, echocardiography, thallium-201 single photon emission computed tomography, catheter and MDCT coronary angiography. Results After clinical assessment, the presence of myocardial infarctions were found in 27 territories (19 AMI and 8 CMI) of 23 patients. Early perfusion defects were observed in 30 territories of all 23 patients. Three territories not corresponding to a myocardial infarction were detected in three patients with AMI and were associated with artifacts. Fourteen of perfusion defects were in the left anterior descending artery territory, four in the left circumflex artery territory, and nine in the right coronary artery territory. Delayed enhancement was observed in 25 territories (17 AMI and 8 CMI) of 21 patients. Delayed enhancement patterns were variable. Transmural early perfusion defects (n =12) were closely associated with transmural late enhancement (n = 5) and subendocardial residual defect with subepicardial late enhancement (n = 5). Conclusion Myocardial infarction showed early perfusion defects and variable delayed enhancement patterns on two-phase contrast-enhanced MDCT. Delayed enhancement technique of MDCT could provide additional information of the location and extent of infarcted myocardium, and could be useful to plan appropriate therapeutic strategies in patients with AMI. PMID:17420626

  14. Early and Delayed Myocardial Enhancement in Myocardial Infarction Using Two-Phase Contrast-Enhanced Multidetector-Row CT

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Sung-Min; Kim, Young-Whan; Han, Seong-Wook [University of Keimyung College of Medicine, Dongsan Medical Center, Daegu (Korea, Republic of); Seo, Joon-Beom [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    The purpose of this study was to describe the myocardial enhancement patterns in patients with myocardial infarction using two-phase contrast enhanced multidetector-row computed tomography (MDCT). Twenty-three patients with clinically proven myocardial infarction (17 acute myocardial infarction [AMI] and 6 chronic myocardial infarction [CMI]) were examined with two-phase contrast-enhanced ECG-gated MDCT. The presence, location, and patterns of myocardial enhancement on two phase MDCT images were compared with infarcted myocardial territories determined by using electrocardiogram, echocardiography, thallium-201 single photon emission computed tomography, catheter and MDCT coronary angiography. After clinical assessment, the presence of myocardial infarctions were found in 27 territories (19 AMI and 8 CMI) of 23 patients. Early perfusion defects were observed in 30 territories of all 23 patients. Three territories not corresponding to a myocardial infarction were detected in three patients with AMI and were associated with artifacts. Fourteen of perfusion defects were in the left anterior descending artery territory, four in the left circumflex artery territory, and nine in the right coronary artery territory. Delayed enhancement was observed in 25 territories (17 AMI and 8 CMI) of 21 patients. Delayed enhancement patterns were variable. Transmural early perfusion defects (n =12) were closely associated with transmural late enhancement (n = 5) and subendocardial residual defect with subepicardial late enhancement (n = 5). Myocardial infarction showed early perfusion defects and variable delayed enhancement patterns on two-phase contrast-enhanced MDCT. Delayed enhancement technique of MDCT could provide additional information of the location and extent of infarcted myocardium, and could be useful to plan appropriate therapeutic strategies in patients with AMI.

  15. Prospectively ECG Gated CT pulmonary angiography versus helical ungated CT pulmonary angiography: Impact on cardiac related motion artifacts and patient radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Shuman, William P., E-mail: wshuman@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Leipsic, Jonathon A., E-mail: JLeipsic@providencehealth.bc.ca [University of British Columbia and St. Paul' s Hospital, Department of Radiology, 1081 Burrard Street, Vancouver, BC, V6Z1Y6 (Canada); Busey, Janet M., E-mail: jbonny@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Green, Douglas E., E-mail: dougreen@uw.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Pipavath, Sudhakar N., E-mail: snjp@u.wwashington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Hague, Cameron J., E-mail: cjhague@interchange.ubc.ca [University of British Columbia and St. Paul' s Hospital, Department of Radiology, 1081 Burrard Street, Vancouver, BC, V6Z1Y6 (Canada); Koprowicz, Kent M., E-mail: kentk@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States)

    2012-09-15

    Objective: To compare prospectively ECG gated CT pulmonary angiography (CTPA) with routine helical ungated CTPA for cardiac related motion artifacts and patient radiation dose. Subjects and methods: Twenty patients with signs and symptoms suspicious for pulmonary embolism and who had a heart rate below 85 were scanned with prospectively ECG gated CTPA. These gated exams were matched for several clinical parameters to exams from twenty similar clinical patients scanned with routine ungated helical CTPA. Three blinded independent reviewers subjectively evaluated all exams for overall pulmonary artery enhancement and for several cardiac motion related artifacts, including vessel blurring, intravascular shading, and double line. Reviewers also measured pulmonary artery intravascular density and image noise. Patient radiation dose for each technique was compared. Fourteen clinical prospectively ECG gated CTPA exams from a second institution were evaluated for the same parameters. Results: Prospectively ECG gated CTPA resulted in significantly decreased motion-related image artifact scores in lung segments adjacent to the heart compared to ungated CTPA. Measured image noise was not significantly different between the two types of CTPA exams. Effective dose was 28% less for prospectively ECG gated CTPA (4.9 mSv versus 6.8 mSv, p = 0.02). Similar results were found in the prospectively ECG gated exams from the second institution. Conclusion: Compared to routine helical ungated CTPA, prospectively ECG gated CTPA may result in less cardiac related motion artifact in lung segments adjacent to the heart and significantly less patient radiation dose.

  16. Magnetic resonance myocardial perfusion imaging-First experience at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, B. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: bernhard.klumpp@med.uni-tuebingen.de; Hoevelborn, T. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: tobias.hoevelborn@gmx.de; Fenchel, M. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: michael.fenchel@med.uni-tuebingen.de; Stauder, N.I. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: norbert.stauder@stgag.ch; Kramer, U. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: ulrich.kramer@med.uni-tuebingen.de; May, A. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: andreas.may@med.uni-tuebingen.de; Gawaz, M.P. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Cardiology, Otfried-Mueller-Str. 10, 72076 Tuebingen (Germany)], E-mail: meinrad.gawaz@med.uni-tuebingen.de; Claussen, C.D. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: claus.claussen@med.uni-tuebingen.de; Miller, S. [Eberhard-Karls-University Tuebingen, University Hospital Tuebingen, Department of Diagnostic Radiology, Hoppe-Seyler-Str. 3, 72076 Tuebingen (Germany)], E-mail: stephan.miller@med.uni-tuebingen.de

    2009-01-15

    Objective: MR myocardial perfusion imaging (MRMPI) is an established technique for the evaluation of the hemodynamical relevance of coronary artery disease. Perfusion imaging at 3.0 T provides certain advantages compared to 1.5 T. Aim of this study was to evaluate myocardial MR perfusion imaging at 3.0 T. Materials and methods: Twelve patients with stable Angina pectoris and known or suspected coronary artery disease were examined at 3.0 T. Myocardial perfusion was assessed using a saturation recovery gradient echo 2D sequence (TR 1.9 ms, TE 1.0 ms, FA 12 deg.) with 0.05 mmol Gd-DTPA per kg body weight at stress during injection of 140 {mu}g adenosine/kg body weight/min and at rest in short axis orientation. Perfusion analysis was based on a least square fit of the signal/time curve (peak signal intensity, slope). Perfusion series were assessed by two independent observers. Reference for the presence of relevant coronary artery stenoses was invasive coronary angiography. Two experienced observers evaluated the coronary angiograms in biplane projections for the presence and grade of stenoses. Results were compared with the MR perfusion analysis. Results: All MR examinations could be safely performed and yielded high image quality. In eight patients stress-induced hypoperfusion was detected (stenosis >70% in coronary angiography). In four patients myocardial hypoperfusion was ruled out (stenosis <70%). The myocardial perfusion reserve index was significantly reduced in hypoperfused myocardium with 1.9 {+-} 1.6 compared to 2.5 {+-} 1.6 in regularly perfused myocardium (p < 0.05). In coronary angiography, eight patients were found to suffer from coronary artery disease, whereas in four patients coronary artery disease was ruled out. Conclusion: Our initial results show that MRMPI at 3.0 T provides reliably high-image quality and diagnostic accuracy.

  17. Correlation between myocardial dysfunction and perfusion impairment in diabetic rats with velocity vector imaging and myocardial contrast echocardiography.

    Science.gov (United States)

    Wei, Zhangrui; Zhang, Haibin; Su, Haili; Zhu, Ting; Zhu, Yongsheng; Zhang, Jun

    2012-11-01

    The purpose of this study was to investigate whether myocardial systolic dysfunction and perfusion impairment occur in diabetic rats, and to assess their relationship using velocity vector imaging (VVI) and myocardial contrast echocardiography (MCE). Forty-six rats were randomly divided into either control or the diabetes mellitus (DM) groups. DM was induced by intraperitoneal administration of streptozotocin. Twelve weeks later, 39 survival rats underwent VVI and MCE in short-axis view at the middle level of the left ventricle, both at rest and after dipyridamole stress. VVI-derived contractile parameters included peak systolic velocity (Vs ), circumferential strain (εc ), strain rate (SRc ), and their reserves. MCE-derived perfusion parameters consisted of myocardial blood flow (MBF) and myocardial flow reserve (MFR). At rest, SRc in the DM group was significantly lower than in the control group, Vs , εc , and MBF did not differ significantly between groups. After dipyridamole stress, all VVI parameters and their reserves in the DM group were significantly lower than those in the control group, MBF and MFR were substantially lower than those in the control group, too. Meanwhile, significant correlations between VVI parameter reserves and MFR were observed in the DM group. Both myocardial systolic function and perfusion were impaired in DM rats. Decreased MFR could be an important contributor to the reduction in myocardial contractile reserve.

  18. The role of metamizol induction for the detection of perfusion reversibility on thallium-201 myocardial perfusion scintigraphy.

    Science.gov (United States)

    Aksoy, Tamer; Ergün, Eser Lay; Ergün, Hakan

    2011-02-01

    Metamizol, probably with its vascular smooth muscle relaxant effect, enhances rest myocardial perfusion with the use of technetium-99m-methoxyisobutylisonitrile. We aimed to investigate whether metamizol induction is also able to increase the detectability of the ischemic/jeopardized myocardium during thallium-201 myocardial perfusion scintigraphy (MPS). Twenty patients who had partially reversible/irreversible perfusion defects on their routine stress-redistribution-reinjection thallium-201 MPS were enrolled and metamizol-induced thallium-201 MPS (111 MBq thallium-201 was injected 45 min after 1 g oral metamizol) was acquired (10 min, 1 and 3 h later). Routine MPS and metamizol-induced MPS images were interpreted on the model of 17 segments using a visual uptake score (VUS; 0=normal, 1=mild, 2=moderate, 3=significant decreases, 4=no uptake). Thallium-201 uptake ratios (mean counts in the region of the perfusion defect/mean counts in the region of the normal-perfused wall) were calculated for each MPS. Blood pressure was monitored at 15-min intervals. MPS were compared with coronary angiography results. Visual uptake score and thallium-201 uptake ratio results indicated that in the first and third hour metamizol-induced thallium-201 uptake was significantly higher (Pmetamizol-induced MPS. Metamizol increases the detectability of ischemic/viable myocardium during MPS with thallium-201 and could be used with MPS.

  19. Acute myocardial infarction: estimation of at-risk and salvaged myocardium at myocardial perfusion SPECT 1 month after infarction.

    Science.gov (United States)

    Romero-Farina, Guillermo; Aguadé-Bruix, Santiago; Candell-Riera, Jaume; Pizzi, M Nazarena; Pineda, Victor; Figueras, Jaume; Cuberas, Gemma; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David

    2013-11-01

    To estimate at-risk and salvaged myocardium by using gated single photon emission computed tomography (SPECT) myocardial perfusion imaging after acute myocardial infarction (AMI). The study was approved by the hospital's Ethical Committee on Clinical Trials (trial register number, PR(HG)36/2000), and all patients gave informed consent. Forty patients (mean age, 61.78 years; eight women) with a first AMI underwent two gated SPECT examinations--one before percutaneous coronary intervention (PCI) and one 4-5 weeks after PCI. Myocardium at risk was estimated by assessing the perfusion defect at the first gated SPECT examination, and salvaged myocardium was estimated by assessing the risk area minus necrosis at the second examination. Myocardium at risk was estimated by determining the discordance between the areas of left ventricular (LV) wall motion and perfusion at the second examination. Concordance between tests was analyzed by means of linear regression analysis, the Pearson correlation, the intraclass correlation coefficient, and Bland-Altman analysis. An improvement in perfusion, wall motion, wall thickening, and LV ejection fraction (P Myocardial perfusion gated SPECT performed 1 month after early PCI in a first AMI provides potentially useful information on at-risk and salvaged myocardium. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122324/-/DC1. RSNA, 2013

  20. Effect of beam hardening on transmural myocardial perfusion quantification in myocardial CT imaging

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    The detection of subendocardial ischemia exhibiting an abnormal transmural perfusion gradient (TPG) may help identify ischemic conditions due to micro-vascular dysfunction. We evaluated the effect of beam hardening (BH) artifacts on TPG quantification using myocardial CT perfusion (CTP). We used a prototype spectral detector CT scanner (Philips Healthcare) to acquire dynamic myocardial CTP scans in a porcine ischemia model with partial occlusion of the left anterior descending (LAD) coronary artery guided by pressure wire-derived fractional flow reserve (FFR) measurements. Conventional 120 kVp and 70 keV projection-based mono-energetic images were reconstructed from the same projection data and used to compute myocardial blood flow (MBF) using the Johnson-Wilson model. Under moderate LAD occlusion (FFR~0.7), we used three 5 mm short axis slices and divided the myocardium into three LAD segments and three remote segments. For each slice and each segment, we characterized TPG as the mean "endo-to-epi" transmural flow ratio (TFR). BH-induced hypoenhancement on the ischemic anterior wall at 120 kVp resulted in significantly lower mean TFR value as compared to the 70 keV TFR value (0.29+/-0.01 vs. 0.55+/-0.01 pmeasured between 120 kVp and 70 keV mean TFR values on segments moderately affected or unaffected by BH. In the entire ischemic LAD territory, 120 kVp mean endocardial flow was significantly reduced as compared to mean epicardial flow (15.80+/-10.98 vs. 40.85+/-23.44 ml/min/100g; pBH was effectively minimized resulting in mean endocardial MBF of 40.85+/-15.3407 ml/min/100g vs. 74.09+/-5.07 ml/min/100g (p=0.0054) in the epicardium. We also found that BH artifact in the conventional 120 kVp images resulted in falsely reduced MBF measurements even under non-ischemic conditions.

  1. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi [Sumitomo Hospital, Osaka (Japan)

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress {sup 99m}Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest {sup 123}I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and {sup 123}I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by {sup 123}I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in {sup 123}I-BMIPP). Eighteen normotensive patients with apical defect by {sup 123}I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by {sup 123}I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by {sup 123}I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and {sup 123}I-BMIPP imaging are useful for the identification of these patients. (author)

  2. Aortic knob width reflects left ventricular diastolic function assessed by gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion.

    Science.gov (United States)

    Kurisu, Satoshi; Higaki, Tadanao; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-04-01

    Aortic knob width on chest radiography represents the extent of aortic dialation and tortuosity of the aortic arch. We tested the hypothesis that aortic knob width reflected left ventricular (LV) diastolic function assessed by gated myocardial perfusion single photon emission computed tomography (SPECT) in patients with normal myocardial perfusion. One hundred and thirty patients with preserved LV ejection fraction and normal myocardial perfusion were enrolled in this study. Aortic knob width was measured along the horizontal line from the point of the lateral edge of the trachea to the left lateral wall of the aortic knob. The peak filling rate (PFR) and the one-third mean filling rate (1/3 MFR) were obtained as LV diastolic parameters. There were 114 male and 16 female patients. Age ranged from 43 to 88 years (69.9 ± 8.9 years). Aortic knob width ranged from 24.2 to 53.4 mm (37.6 ± 5.7 mm). There was a significant correlation between age and aortic knob width (r = 0.34, p perfusion.

  3. Evaluation of myocardial CT perfusion in patients presenting with acute chest pain to the emergency department: comparison with SPECT-myocardial perfusion imaging.

    Science.gov (United States)

    Feuchtner, Gudrun Maria; Plank, Fabian; Pena, Constantino; Battle, Juan; Min, James; Leipsic, Jonathon; Labounty, Troy; Janowitz, Warren; Katzen, Barry; Ziffer, Jack; Cury, Ricardo C

    2012-10-01

    To determine whether evaluation of resting myocardial CT perfusion (CTP) from coronary CT angiography (CTA) datasets in patients presenting with chest pain (CP) to the emergency department (ED), might have added value to coronary CTA. 76 Patients (age 54.9 y±13; 32 (42%) women) presenting with CP to the ED underwent coronary 64-slice CTA. Myocardial perfusion defects were evaluated for CTP (American Heart Association 17-segment model) and compared with rest sestamibi single-photon emission CT myocardial perfusion imaging (SPECT-MPI). CTA was assessed for >50% stenosis per vessel. CTP demonstrated a sensitivity of 92% and 89%, specificity of 95% and 99%, positive predictive value (PPV) of 80% and 82% and negative predictive value (NPV) of 98% and 99% for each patient and for each segment, respectively. CTA showed an accuracy of 92%, sensitivity of 70.4%, specificity of 95.5%, PPV 67.8%, and NPV of 95% compared with SPECT-MPI. When CTP findings were added to CTA the PPV improved from 67% to 90.1%. In patients presenting to the ED with CP, the evaluation of rest myocardial CTP demonstrates high diagnostic performance as compared with SPECT-MPI. Addition of CTP to CTA improves the accuracy of CTA, primarily by reducing rates of false-positive CTA.

  4. Comparison of Adenosine Stress Myocardial Perfusion Scintigraphy and Oral Dipyridamole Stress Myocardial Perfusion Scintigraphy for Hemodynamic Changes and Adverse Effects

    Directory of Open Access Journals (Sweden)

    Ahmet Yanarateş

    2016-08-01

    Full Text Available Objective: Similar effects can be achieved during stress myocardial perfusion scintigraphy (MPS using pharmacological agents to create cardiac stress for patients who are unable to exercise. In our study, we aimed to show the hemodynamic changes and adverse effects caused by adenosine and to compare the results with dipyridamole stress MPS. Materials and Methods: Sixty-five patients with suspected coronary artery disease were included in our study. Fifty patients in whom stress MPS with intravenous adenosine was performed (group A and 15 patients who underwent oral dipyridamole stress MPS (group B were retrospectively evaluated. During the test, blood pressure measurements and electrocardiographic follow-up were performed in all patients and side effects were noted. Results: At least one side effect occurred in 68% of the group A and in 46% of the group B patients. There was no statistically significant difference between the two groups in terms of side effects that occurred during the pharmacological stress. During the maximum stress, there was an increase of 15.80±11.60 beats/min in heart beats in group A and 5.53±4.54 beats/min in group B. There was a statistically significant difference between the groups in terms of heart rate increase per minute. When we compared reduction in systolic blood pressure and diastolic blood pressure, there was no statistically significant difference between the two groups. Conclusion: Although side effects are more often seen with adenosine, rapid decline in complaints was observed when adenosine infusion was terminated and there was no need for patient follow-up due to short half life of adenosine. We believe that these favourable advantages will increase the use of adenosine in clinical practice.

  5. Low-dose dobutamine myocardial perfusion scintigraphy in the identification of viable myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Renata Freire de [Instituto Hermes Pardini, Belo Horizonte, MG (Brazil). Dept. of Molecular Imaging and Diagnosis. Div. of Nuclear Medicine; Meneghetti, Jose Claudio [Instituto do Coracao (InCor-HC/FM/USP), Sao Paulo, SP (Brazil). Unit of Nuclear Medicine and Molecular Imaging; Barroso, Adelanir Antonio, E-mail: renatafreire@yahoo.com.b [Nuclear Medcenter, Belo Horizonte, MG (Brazil)

    2010-09-15

    Objective: to evaluate the increase in specificity of dual isotope myocardial perfusion gated SPECT ({sup 99m}Tcsestamibi/thallium-201), a highly sensitive method to detect viable myocardium, with addition of data on contractile reserve simultaneously acquired by low-dose dobutamine gated SPECT, similarly to echocardiography. Materials and methods: a total of 260 myocardial segments were assessed in 13 patients with myocardial infarction referred for investigation of myocardial viability before undergoing revascularization. Cellular integrity and contractile reserve were evaluated by dual isotope perfusion myocardial gated SPECT with thallium rest and redistribution images and post-stress {sup 99m}Tc-sestamibi gated-SPECT images under basal conditions and with low-dose dobutamine. The improvement in the contractile performance detected by post-revascularization {sup 99m}Tc-sestamibi gated SPECT was the parameter considered for determining myocardial viability. For the purpose of results analysis, the functional parameters of the myocardial segments were quantified at the different phases of the study and stratified according to their viability for a later post-revascularization functional comparison. Results: in the statistical analysis, systolic wall thickening demonstrated to be a relevant parameter in the evaluation of myocardial contractile reserve by this method, with a tendency of improvement in the specificity (84%), demonstrating higher values than those observed in the literature. Conclusion: this method tends to present an effective contribution in the assessment of myocardial viability. (author)

  6. Lung mass appearing as a dilated left ventricle on Tc-99m tetrofosmin myocardial perfusion scintigraphy.

    Science.gov (United States)

    Gnanasegaran, Gopinath; Williams, Robert; Mclean, Emma; O' Connell, Rachel; Nunan, Thomas O; O'Doherty, Michael J

    2009-09-01

    Tc-99m tetrofosmin is a common tracer used in myocardial perfusion scintigraphy. Several benign and malignant tumors also take up tetrofosmin. We present a case of a 60-year-old woman with a history of a left lung mass awaiting resection. The patient was referred for a myocardial perfusion scan for preoperative risk assessment. The myocardial perfusion scan revealed a large cavitated lesion mimicking a dilated left ventricle and the CT scan revealed a large mass in the left lung with central necrosis displacing the heart and mediastinum. The patient underwent thoracotomy with resection of the mass and the histology confirmed atypical carcinoid. This case highlights noncardiac uptake of Tc-99m tetrofosmin in an atypical carcinoid.

  7. Discrepancy between myocardial perfusion and fatty acid metabolism following acute myocardial infarction for evaluating the dysfunctional viable myocardium.

    Science.gov (United States)

    Biswas, Shankar K; Sarai, Masayoshi; Toyama, Hiroshi; Hishida, Hitoshi; Ozaki, Yukio

    2012-01-01

    Following acute myocardial infarction (AMI) the area of myocardial perfusion and metabolism mismatch is designated as dysfunctional viable myocardium. (123)I-beta-methyl iodophenyl pentadecanoic acid (BMIPP) is clinically very useful for evaluating myocardial fatty acid metabolism, and (99)mTc-Tetrofosmin (TF) is a widely used tracer for myocardial perfusion. This study was designed to evaluate the degree of discrepancy between BMIPP and TF at the subacute state of AMI. Fifty-two patients (aged 59 ± 10 years; mean 46 years) with AMI were enrolled, and all of them underwent percutaneous coronary intervention (PCI). Patients were classified according to ST-T change and PCI timing. (123)I-beta-methyl iodophenyl pentadecanoic acid and TF cardiac scintigraphy were performed on 7 ± 3.5 days of admission using a dual headed gamma camera. Perfusion and fatty acid metabolism defect were scored on a 17 segments model. The mean BMIPP defect score on early and delayed images were 16.67 ± 10.19 and 16.25 ± 10.40, respectively. The mean TF defect score was 10 ± 7.69. Defect score of BMIPP was significantly higher than that of the TF (P TF), and 5 (10%) patients showed matched defect (BMIPP = TF). Mismatched defect score (MMDS) was significantly higher in patients with ST-segment elevation myocardial infarction (STEMI) than that of non-ST-segment elevation myocardial infarction (NSTEMI) (P < 0.041; 95% CI 0.11-5.19). At the subacute state of AMI, most of the patients showed perfusion-metabolism mismatch, which represents the dysfunctional viable myocardium, and patients with STEMI showed higher mismatch. Copyright © 2012 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  8. Performance of adenosine "stress-only" perfusion MRI in patients without a history of myocardial infarction : a clinical outcome study

    NARCIS (Netherlands)

    Lubbers, Daniel D.; Rijlaarsdam-Hermsen, Dorine; Kuijpers, Dirkjan; Kerkhof, Marjan; Sijens, Paul E.; van Dijkman, Paul R. M.; Oudkerk, Matthijs

    To assess the diagnostic value of adenosine "stress-only" myocardial perfusion MR for ischemia detection as an indicator for coronary angiography in patients without a prior myocardial infarction and a necessity to exclude ischemia. Adenosine perfusion MRI was performed at 1.5 T in 139 patients with

  9. High-frequency Electrocardiogram Analysis in the Ability to Predict Reversible Perfusion Defects during Adenosine Myocardial Perfusion Imaging

    Science.gov (United States)

    Tragardh, Elin; Schlegel, Todd T.; Carlsson, Marcus; Pettersson, Jonas; Nilsson, Klas; Pahlm, Olle

    2007-01-01

    Background: A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on myocardial perfusion imaging (MPI) scans during adenosine. The purpose of the present study was to try to reproduce those findings. Methods: 12-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine Tc-99m-tetrofosmin MPI tests. HF-QRS were analyzed regarding morphology and changes in root mean square (RMS) voltages from before the adenosine infusion to peak infusion. Results: The best area under the curve (AUC) was found in supine patients (AUC=0.736) in a combination of morphology and RMS changes. None of the measurements, however, were statistically better than tossing a coin (AUC=0.5). Conclusion: Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.

  10. Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction

    Science.gov (United States)

    Eck, Brendan L.; Fahmi, Rachid; Fuqua, Christopher; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2015-03-01

    Dynamic myocardial CT perfusion (CTP) can provide quantitative functional information for the assessment of coronary artery disease. However, x-ray dose in dynamic CTP is high, typically from 10mSv to >20mSv. We compared the dose reduction potential of advanced iterative reconstruction, Iterative Model Reconstruction (IMR, Philips Healthcare, Cleveland, Ohio) to hybrid iterative reconstruction (iDose4) and filtered back projection (FBP). Dynamic CTP scans were obtained using a porcine model with balloon-induced ischemia in the left anterior descending coronary artery to prescribed fractional flow reserve values. High dose dynamic CTP scans were acquired at 100kVp/100mAs with effective dose of 23mSv. Low dose scans at 75mAs, 50mAs, and 25mAs were simulated by adding x-ray quantum noise and detector electronic noise to the projection space data. Images were reconstructed with FBP, iDose4, and IMR at each dose level. Image quality in static CTP images was assessed by SNR and CNR. Blood flow was obtained using a dynamic CTP analysis pipeline and blood flow image quality was assessed using flow-SNR and flow-CNR. IMR showed highest static image quality according to SNR and CNR. Blood flow in FBP was increasingly over-estimated at reduced dose. Flow was more consistent for iDose4 from 100mAs to 50mAs, but was over-estimated at 25mAs. IMR was most consistent from 100mAs to 25mAs. Static images and flow maps for 100mAs FBP, 50mAs iDose4, and 25mAs IMR showed comparable, clear ischemia, CNR, and flow-CNR values. These results suggest that IMR can enable dynamic CTP at significantly reduced dose, at 5.8mSv or 25% of the comparable 23mSv FBP protocol.

  11. The effect of captopril on thallium 201 myocardial perfusion in systemic sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Kahan, A.; Devaux, J.Y.; Amor, B.; Menkes, C.J.; Weber, S.; Venot, A.; Strauch, G. (Rene Descartes Univ., Paris (France))

    1990-04-01

    In systemic sclerosis, abnormalities of myocardial perfusion are common and may be caused by a disturbance of the coronary microcirculation. We evaluated the long-term effect of captopril (75 to 150 mg per day) on thallium 201 myocardial perfusion in 12 normotensive patients with systemic sclerosis. Captopril significantly decreased the mean (+/- SD) number of segments with thallium 201 myocardial perfusion defects (6.5 +/- 1.9 at baseline and 4.4 +/- 2.7 after 1 year of treatment with captopril; p less than 0.02) and increased the mean global thallium score (9.6 +/- 1.7 at baseline and 11.4 +/- 2.1 after captopril; p less than 0.05). In a control group of eight normotensive patients with systemic sclerosis who did not receive captopril, no significant modification in thallium results occurred. Side effects with captopril included hypotension (six patients), taste disturbances (one patient), and skin rash (one patient). These side effects subsided when the dosage was reduced. These findings demonstrate that captopril improves thallium 201 myocardial perfusion in patients with systemic sclerosis and may therefore have a beneficial effect on scleroderma myocardial disease.

  12. Myocardial perfusion alterations observed months after radiotherapy are related to the cellular damage

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, I.; Sonmez, B. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Nuclear Medicine; Sezen, O.; Zengin, A.Y.; Bahat, Z. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Radiation Oncology; Yenilmez, E.; Yulug, E. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Histology and Embryology; Abidin, I. [Karadeniz Technical Univ., Trabzon (Turkey). Dept. of Biophysics

    2010-07-01

    Myocardial perfusion scintigraphy (MPS) is one of the widely used tools to follow developing radiation-induced heart disease (RIHD). But the clinical significance of MPS defects has not been fully understood. We have investigated the biodistribution alterations related to perfusion defects following radiotherapy (RT) and showed coexisting morphological changes. Animals, methods: A total of 18 Wistar rats were divided into three groups (1 control and 2 irradiated groups). A single cardiac 20 Gy radiation dose was used to induce long term cardiac defects. Biodistribution studies with technetium ({sup 99m}Tc) sestamibi and histological evaluations were performed 4 and 6 months after irradiation. The percent radioactivity (%ID/g) was calculated for each heart. For determination of the myocardial damage, positive apoptotic cardiomyocytes, myocardial cell degeneration, myocardial fibrosis, vascular damage and ultrastructural structures were evaluated. Results: Six months after treatment, a significant drop of myocardial uptake was observed (p < 0.05). Irradiation-induced apoptosis rose within the first 4 months after radiation treatment and were stayed elevated until the end of the observation period (p < 0.05). Also, the irradiation has induced myocardial degeneration, perivascular and interstitial fibrosis in the heart at the end of six and four months (p < 0.01). The severity and extent of myocardial injury has became more evident at the end of six month (p < 0.05). At ultrastructural level, prominent changes have been observed in the capillary endothelial and myocardial cells. Conclusion: Our findings suggest that the reduced rest myocardial perfusion, occuring months after the radiation, indicates a serious myocard tissue damage which is characterized by myocardial degeneration and fibrosis. (orig.)

  13. Impairment of myocardial perfusion in children with sickle cell disease; Alteration de la perfusion myocardique chez l'enfant drepanocytaire

    Energy Technology Data Exchange (ETDEWEB)

    Maunoury, C. [Hopital Necker-Enfants-Malades, Service de Medecine Nucleaire, 75 - Paris (France); Acar, P. [Centre Hospitalier Universitaire, Hopital des Enfants, Service de Cardiologie Pediatrique, 31 - Toulouse (France); Montalembert, M. de [Hopital Necker-Enfants-Malades, Service de Pediatrie Generale, 75 - Paris (France)

    2003-10-01

    While brain, bone and spleen strokes are well documented in children with sickle cell disease (SCD), impairment of myocardial perfusion is an unknown complication. Non invasive techniques such as exercise testing and echocardiography have a low sensitivity to detect myocardial ischemia in patients with SCD. We have prospectively assessed myocardial perfusion with Tl-201 SPECT in 23 patients with SCD (10 female, 13 male, mean age 12 {+-} 5 years). Myocardial SPECT was performed after stress and 3 hours later after reinjection on a single head gamma camera equipped with a LEAP collimator (64 x 64 matrix size format, 30 projections over 180 deg C, 30 seconds per step). Left ventricular ejection fraction (LVEF) was assessed by equilibrium radionuclide angiography at rest on the same day. Myocardial perfusion was impaired in 14/23 patients: 9 reversible defects and 5 fixed defects. The left ventricular cavity was dilated in 14/23 patients. The mean LVEF was 63 {+-} 9%. There was no relationship between myocardial perfusion and left ventricular dilation or function. The frequent impairment of myocardial perfusion in children with SCD could lead to suggest a treatment with hydroxyurea, an improvement of perfusion can be noted with hydroxyurea. (author)

  14. GATED SPECT TO EVALUATE LEFT VENTRICULAR MYOCARDIAL PERFUSION, FUNCTION AND DYSSYNCHRONY FOR RESYNCHRONIZATION THERAPY

    Directory of Open Access Journals (Sweden)

    E.N. Ostroumov

    2009-01-01

    Full Text Available The study included 15 consecutive patients with heart failure and substantial LV dyssynchrony undergoing CRT. Clinical and phase analysis of gated myocardial perfusion SPECT assessed at baseline, after 2–3 days and after 3–4 months of CRT. The results demonstrated inversely relationship between the response to CRT and the nonviable myocardium. Evaluation of myocardial viability is necessary to considered in the selection process for CRT.

  15. Reverse Redistribution in Myocardial Perfusion Imaging: Revisited with 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Kim, Jeong Ho; Hwang, Kyung Hoon; Choi, In Suck; Choi, Soo Jin; Choe, Won Sick [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of)

    2010-06-15

    The authors report myocardial perfusion imaging of a patient showing reverse redistribution (RR) and a 64-slice multidetector-row computed tomography (MDCT) with corresponding findings. The patient had subendocardial myocardial infarction (MI) with positive electrocardiogram (EMG) findings and elevated levels of cardiac isoenzymes. Experiencing this case emphasizes the importance of complementary correlation of a new diagnostic modality that helps us to understand the nature of RR.

  16. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement

    DEFF Research Database (Denmark)

    Marcassa, C.; Bax, J.J.; Bengel, F.

    2008-01-01

    Mortality rates due to coronary artery disease (CAD) have declined in recent years as result of improved prevention, diagnosis, and management. Nonetheless, CAD remains the leading cause of death worldwide with most casualties expected to occur in developing nations. Myocardial perfusion...... scintigraphy (MPS) provides a highly cost-effective tool for the early detection of obstructive CAD in symptomatic individuals and contributes substantially to stratification of patients according to their risk of cardiac death or nonfatal myocardial infarction. MPS also provides valuable information...

  17. Perfusion imaging using rubidium-82 ((82)Rb) PET in rats with myocardial infarction

    DEFF Research Database (Denmark)

    Clemmensen, Andreas Ettrup; Ghotbi, Adam Ali; Bodholdt, Rasmus Poul

    2017-01-01

    Assessing myocardial perfusion using 82Rb-PET is emerging as a valuable clinical tool.1,2 The rapid decay (T½ = 76 s) allows for absolute quantification of both rest and stress perfusion within 30 minutes. In addition to evaluation of epicardial disease with perfusion defects, also evaluation...... of balanced coronary and small vessel disease is possible. For further evaluation of how 82Rb-PET can be used clinically, pre-clinical application of the method would be valuable. However, so far no data on the use of 82Rb-PET in small animals have been published nor has the use of 82Rb-PET, to the best...

  18. Correlation of the myocardial perfusion corrected by attenuation with the coronariography. Preliminary results; Correlacion de la perfusion miocardica corregida por atenuacion con la coronariografia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia C, S.E.; Garcia O, R. [Servicio de Medicina Nuclear, Centro Medico ABC, Campis Observatorio, IAP (Mexico)

    2005-07-01

    The attenuation that suffers the radiation in the soft tissues of the hinders the appropriate interpretation of the myocardial perfusion studies, for what have been implemented attenuation correction systems to reduce the attenuation for soft tissues and to provide myocardial perfusion images more accurate in the diagnosis of coronary illness. The objective was to evaluate the utility of an attenuation correction system (with source of Gadolinium 153) to minimize the devices that look like true defects of myocardial perfusion, caused by soft tissues (mammary tissue, thoracic wall, abdomen, left hemi diaphragm), and to compare those interpretations of the studies with the interpretations of the corresponding coronariographies. The method consists of 95 electronic files which were revised with the concept of heart catheterization, being identified 20 patients from the masculine sex to those that underwent coronariography among May 1999 and December 2002, and that they had study of myocardial perfusion in a maximum period of 3 months foresaw to the invasive procedure. (Author)

  19. Early myocardial damage assessment in dystrophinopathies using 99Tcm-MIBI gated myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Zhang L

    2015-12-01

    Full Text Available Li Zhang,1,* Zhe Liu,2,* Ke-You Hu,3 Qing-Bao Tian,3 Ling-Ge Wei,4 Zhe Zhao,5 Hong-Rui Shen,5 Jing Hu5 1Department of Cardiovascular Disorders, 2Department of Geriatrics, The Third Hospital of Hebei Medical University, 3The Public Health Department, Hebei Medical University, 4Department of Nuclear Medicine, 5Department of Neuromuscular Disorders, The Third Hospital of Hebei Medical University, Shijiazhuang, People’s Republic of China *Li Zhang and Zhe Liu are first coauthors of this paper Background: Early detection of muscular dystrophy (MD-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile (99Tcm-MIBI gated myocardial perfusion imaging (G-MPI for MD.Methods and results: Ninety-one patients underwent 99Tcm-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD (n=77 or Becker muscular dystrophy (BMD; n=14. 99Tcm-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using 99Tcm-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (rs=0.534 [P<0.05] and rs=0.784 [P<0.05], respectively. Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05, but not in BMD patients.Conclusion: 99Tcm-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD

  20. Usefulness of Dipyridamole Myocardial Perfusion SPECT in Patients with Left Bundle Branch Block

    Directory of Open Access Journals (Sweden)

    Naser Aslanabadi

    2006-08-01

    Full Text Available Background: Diagnosis of coronary artery disease (CAD in patients with left bundle branch block (LBBB is considered as a challenge in cardiology due to the low accuracy of noninvasive methods such as basal and stress electrocardiography (ECG. This diagnostic challenge can be reduced but not eliminated using dipyridamole as a stress method instead of exercise. The aim of this study was to assess the diagnostic value of dipyridamole stress Tc-99m Sestamibi single photon emission computed tomography (SPECT myocardial perfusion imaging in patients with complete LBBB. Methods: We studied 40 patients with permanent and complete LBBB using Tc-99m Sestamibi SPECT and dipyridamole stress to evaluate CAD. Perfusion defect was considered fixed when there was no difference between rest and stress score, while reversible defect was defined as a segment with higher score on stress images. All patients underwent coronary angiography. Results: Eleven patients (27.5% had normal myocardial perfusion SPECT and 29 patients (72.5% had reversible perfusion defects. Angiography was positive in 30 patients, while 10 cases showed normal angiography. The sensitivity, specificity, positive predict value and negative predict value of our study for detecting >50% coronary stenosis was 86.6%, 70%, 89% and 64% respectively. Conclusion: We found 33 (82.5% patients with concordant angiography and myocardial perfusion SPECT results (p=0.002. Angiography was positive in 90% of patients with reversible perfusion defects on myocardial perfusion SPECT. In summary, Tc-99m Sestamibi SPECT in patients with LBBB showed high accuracy (82.5% in detecting >50% coronary stenosis.

  1. Prognostic Value of Normal Perfusion but Impaired Left Ventricular Function in the Diabetic Heart on Quantitative Gated Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanjeong; Choi, Sehun; Han, Yeonhee [Research Institute of Chonbuk National Univ. Medical School and Hospitial, Jeonju (Korea, Republic of); Lee, Dong Soo; Lee, Hoyoung; Chung, Junekey [Seoul National Univ., Seoul (Korea, Republic of)

    2013-09-15

    This study aimed at identifying the predictive parameters on quantitative gated myocardial perfusion single-photon emission computed tomography (QG-SPECT) in diabetic patients with normal perfusion but impaired function. Methods Among the 533 consecutive diabetic patients, 379 patients with normal perfusion on rest Tl-201/dipyridamole-stress Tc-{sup 99m} sestamibi Gated SPECT were enrolled. Patients were grouped into those with normal post-stress left ventricular function (Group I) and those with impaired function (EF <50 or impaired regional wall motion, Group II). We investigated cardiac events and cause of death by chart review and telephone interview. Survival analysis and Cox proportional hazard model analysis were performed. Between the Group I and II, cardiac events as well as chest pain symptoms, smoking, diabetic complications were significantly different (P<0.05). On survival analysis, event free survival rate in Group II was significantly lower than in Group I (P=0.016). In univariate Cox proportional hazard analysis on overall cardiac event, Group (II over I), diabetic nephropathy, summed motion score (SMS), summed systolic thickening score (STS), numbers of abnormal segmental wall motion and systolic thickening predicted more cardiac events (P<0.05). Multivariate analysis showed that STS was the only independent predictor cardiac event. The functional parameter, especially summed systolic thickening score on QG-SPECT had prognostic values, despite normal perfusion, in predicting cardiac events in diabetic patients, and QG-SPECT provides clinically useful risk stratification in diabetic patients with normal perfusion.

  2. 99mTc sestamibi myocardial perfusion scintigraphy with the novel use of metamizol for the detection of perfusion reversibility.

    Science.gov (United States)

    Ergün, Eser Lay; Caglar, Meltem; Bozkurt, Murat Fani; Ergün, Hakan

    2008-08-01

    This study aims to investigate whether induction with metamizol, an analgesic-antipyretic drug having spasmolitic activity, could be used to increase the detectability of ischemic/jeopardized myocardium during MPS (myocardial perfusion scintigraphy). Metamizol-enhanced rest MPS (45 min after administration of 1 g metamizol orally, 740 MBq (99m)Tc sestamibi was injected, MPS was acquired 45 min later) was performed in 21 patients who had perfusion defects on their previous stress-rest (99m)Tc sestamibi MPS. Blood pressure was monitored at 15-min intervals. Stress, rest, metamizol-rest MPS images were interpreted on the model of 20 segments using a visual uptake score (VUS; 0 = normal, 1 = mild, 2 = moderate, 3 = significant decreases, 4 = no uptake). (99m)Tc sestamibi uptake ratios (MIBI-UR; mean counts in the region of the perfusion defect/mean counts in the region of the normal-perfused wall) were obtained on each MPS and compared with each other. Average MIBI-UR in each scintigraphic examination was calculated. MPS were compared with coronary angiography results. VUS and MIBI-UR results showed that metamizol-rest MPS displayed the defect reversibility better than rest MPS. Of the 14 segments with fixed perfusion defects on stress-rest MPS, 8 showed improvement of perfusion after metamizol induction. In 33 segments, lesion reversibility was better delineated on metamizol-rest MPS. Metamizol-induced sestamibi uptake was significantly higher (p metamizol induced MPS. Metamizol-enhanced rest MPS increases detectability of ischemic/viable myocardium during MPS. Metamizol should be discontinued like nitrates before stress MPS since it may mask the visualization of ischemic perfusion defects.

  3. Alternative technique using dual source CT imaging for assessment of myocardial perfusion

    Directory of Open Access Journals (Sweden)

    Amgad S. Abdel-Rahman

    2015-06-01

    Conclusion: We propose that comprehensive evaluation of coronary artery morphology and myocardial perfusion in patients with CAD could be achieved by single reproducible non-invasive contrast enhanced CT acquisition using DSCT scanners while operated in single energy mode with high sensitivity, specificity and diagnostic accuracy, it also has the potential to be the first, independent and stand out imaging choice in such field.

  4. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT : 2015 revision

    NARCIS (Netherlands)

    Verberne, Hein J.; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; De Bondt, Pieter; Buechel, Ronny R.; Cuocolo, Alberto; van Eck-Smit, Berthe L. F.; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A.; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J. H. A.; Slart, Riemer H. J. A.; Tragardh, Elin; de Wit, Tim C.; Hesse, Birger

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 201

  5. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT

    DEFF Research Database (Denmark)

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos;

    2015-01-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated ...

  6. Myocardial perfusion scintigraphy in the detection of silent ischemia in asymptomatic diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Glaucia Celeste Rossatto [Clinica Diagnoson and Hospital Aristides Maltez, Salvador, BA (Brazil). Servicos de Medicina Nuclear; Pavin, Elizabeth Joao; Parisi, Maria Candida R. [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Internal Medicine. Service of Endocrinology; Coelho, Otavio Rizzi; Almeida, Raitany C. [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Internal Medicine. Service of Cardiology; Etchebehere, Elba Cristina Sa de Camargo; Ramos, Celso Dario, E-mail: cdramos@unicamp.br [Universidade Estadual de Campinas (Unicamp), Campinas, SP (Brazil). Department of Radiology. Service of Nuclear Medicine; Camargo, Edwaldo Eduardo [Hospital Sirio-Libanes, Campinas, SP (Brazil). Service of Nuclear Medicine

    2013-01-15

    Objective: This study was aimed to evaluate myocardial perfusion in asymptomatic patients with type 1 (DM1) and type 2 diabetes mellitus (DM2) without previous diagnoses of coronary artery disease (CAD) or cerebral infarction. Materials and Methods: Fifty-nine consecutive asymptomatic patients (16 DM1, 43 DM2) underwent myocardial perfusion scintigraphy with {sup 99m}Tc-sestamibi (MPS). They were evaluated for body mass index, metabolic control of DM, type of therapy, systemic arterial hypertension, dyslipidemia, nephropathy, retinopathy, peripheral neuropathy, smoking, and familial history of CAD. Results: MPS was abnormal in 15 patients (25.4%): 12 (20.3%) with perfusion abnormalities, and 3 with isolated left ventricular dysfunction. The strongest predictors for abnormal myocardial perfusion were: age 60 years and above (p = 0.017; odds ratio [OR] = 6.0), peripheral neuropathy (p = 0.028; OR = 6.1), nephropathy (p = 0.031; OR = 5.6), and stress ECG positive for ischemia (p = 0.049; OR = 4.08). Conclusion: Silent myocardial ischemia occurs in more than one in five asymptomatic diabetic patients. The strongest predictors of ischemia in this study were: patient age, peripheral neuropathy, nephropathy, retinopathy and a stress ECG positive for ischemia. (author)

  7. [Myocardial perfusion scintigraphy. Exact and cost-effective coronary disease imaging - secondary publication

    DEFF Research Database (Denmark)

    Hesse, B.; Petersen, C.L.; Marcassa, C.

    2008-01-01

    Mortality rates due to coronary arterial disease (CAD) have declined as result of improved prevention, diagnosis and management, but CAD remains the leading cause of death. Myocardial perfusion scintigraphy (MPS) provides a cost-effective tool for early detection of CAD in symptomatic individuals...

  8. Estimation of x-ray parameters in digital coronary angiography for compensation of myocardial perfusion measurements

    NARCIS (Netherlands)

    Storm, C.J.; Slump, C.H.; Hsieh, J.; Samei, E.

    2008-01-01

    Coronary angiography is the primary technique for diagnosing coronary abnormalities as it is able to locate precisely the coronary artery lesions. However, the clinical relevance of an appearing stenosis is not that easy to assess. In previous work we have analyzed the myocardial perfusion by compar

  9. Interdependence between measures of extent and severity of myocardial perfusion defects provided by automatic quantification programs

    DEFF Research Database (Denmark)

    El-Ali, Henrik Hussein; Palmer, John; Carlsson, Marcus;

    2005-01-01

    To evaluate the accuracy of the values of lesion extent and severity provided by the two automatic quantification programs AutoQUANT and 4D-MSPECT using myocardial perfusion images generated by Monte Carlo simulation of a digital phantom. The combination between a realistic computer phantom...

  10. Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Johansen, Allan; Grupe, Peter; Veje, Annegrete

    2004-01-01

    Attenuation correction may improve the diagnostic accuracy of myocardial perfusion imaging (MPI). However, few studies have dealt with the clinical consequences for reporting. We compared routine reports based on scatter-corrected MPI (MPI-routine) with consensus readings of scatter-corrected (MP...

  11. The etiology and implications of dense cavitary "photopenia" on myocardial perfusion scintigraphy.

    Science.gov (United States)

    Dae, M; Canhasi, B; Botvinick, E; Olvera, S; Schechtmann, N; Engelstad, B; Hattner, R; Schiller, N; O'Connell, W; Faulkner, D

    1985-07-01

    Dense cavitary "photopenia" was observed on 21 of 200 consecutive stress perfusion scintigrams. A prominent finding in many cases, it sometimes occupied only a portion of the region overlying the ventricular cavity, was often seen in some projections and not others, and was frequently adjacent to myocardial perfusion defects. To distinguish an etiology among reduced cavitary radioactivity, relatively increased background radioactivity, or reduced radioactivity in overlying myocardium, quantitative analysis of cavitary, lung and myocardial radioactivity was performed in patients with dense cavitary "photopenia," with and without lung uptake, and compared with results from studies showing increased lung uptake without cavitary photopenia and with normal studies. The results showed that dense cavitary photopenia was related to reduced radioactivity in overlying myocardium. Correlative imaging studies performed with echocardiography and contrast ventriculography confirmed this relationship to myocardial scar in 15 of 21 patients in whom associated akinesis or dyskinesis was seen. Hence, dense cavitary photopenia on stress perfusion scintigraphy is due to a dense myocardial perfusion abnormality, and is often indicative of related scar and an associated severe contraction abnormality.

  12. Etiology and implications of dense cavitary ''photopenia'' on myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dae, M.; Canhasi, B.; Botvinick, E.; Olvera, S.; Schechtmann, N.; Engelstad, B.; Hattner, R.; Schiller, N.; O' Connell, W.; Faulkner, D.

    1985-07-01

    Dense cavitary ''photopenia'' was observed on 21 of 200 consecutive stress perfusion scintigrams. A prominent finding in many cases, it sometimes occupied only a portion of the region overlying the ventricular cavity, was often seen in some projections and not others, and was frequently adjacent to myocardial perfusion defects. To distinguish an etiology among reduced cavitary radioactivity, relatively increased background radioactivity, or reduced radioactivity in overlying myocardium, quantitative analysis of cavitary, lung and myocardial radioactivity was performed in patients with dense cavitary ''photopenia,'' with and without lung uptake, and compared with results from studies showing increased lung uptake without cavitary photopenia and with normal studies. The results showed that dense cavitary photopenia was related to reduced radioactivity in overlying myocardium. Correlative imaging studies performed with echocardiography and contrast ventriculography confirmed this relationship to myocardial scar in 15 of 21 patients in whom associated akinesis or dyskinesis was seen. Hence, dense cavitary photopenia on stress perfusion scintigraphy is due to a dense myocardial perfusion abnormality, and is often indicative of related scar and an associated severe contraction abnormality.

  13. Quantification of myocardial perfusion using free-breathing MRI and prospective slice tracking

    DEFF Research Database (Denmark)

    Pedersen, Henrik; Kelle, Sebastian; Ringgaard, Steffen

    2009-01-01

    Quantification of myocardial perfusion using first-pass magnetic resonance imaging (MRI) is hampered by respiratory motion of the heart. Prospective slice tracking (PST) potentially overcomes this problem, and may provide an attractive alternative or supplement to current breath-hold techniques...

  14. Myocardial Perfusion Reserve After a PET-Driven Revascularization Procedure : A Strong Prognostic Factor

    NARCIS (Netherlands)

    Slart, Riemer H. J. A.; Zeebregts, Clark J.; Hillege, Hans L.; de Sutter, Johan; Dierckx, Rudi A. J. O.; van Veldhuisen, Dirk J.; Zijlstra, Felix; Tio, Rene A.

    2011-01-01

    Not all patients treated on the basis of PET-proven viability benefit from revascularization. Myocardial perfusion reserve (MPR) predicts survival in patients not undergoing revascularization. In the present study, we investigated whether MPR is related to survival in ischemic heart disease (IHD) pa

  15. Optimized Saturation Pulse Train for Human First-Pass Myocardial Perfusion Imaging at 7T

    Science.gov (United States)

    Tao, Yuehui; Hess, Aaron T; Keith, Graeme A; Rodgers, Christopher T; Liu, Alexander; Francis, Jane M; Neubauer, Stefan; Robson, Matthew D

    2015-01-01

    Purpose To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. Methods The new design of saturation pulse train consists of four hyperbolic-secant (HS8) radiofrequency pulses, whose peak amplitudes are optimized for a target range of static and transmit field variations and radiofrequency power deposition restrictions measured in the myocardium at 7T. The proposed method and existing methods were compared in simulation, phantom, and in vivo experiments. Results In healthy volunteer experiments without contrast agent, average saturation efficiency with the proposed method was 97.8%. This is superior to results from the three previously published methods at 86/95/90.8%. The first series of human first-pass myocardial perfusion images at 7T have been successfully acquired with the proposed method. Conclusion Existing saturation methods developed for 3T imaging are not optimal for perfusion imaging at 7T. The proposed new design of saturation pulse train can saturate effectively, and with this method first-pass myocardial perfusion imaging is feasible in humans at 7T. Magn Reson Med 73:1450–1456, 2015. © 2014 The Authors. Magnetic Resonance in Medicine Published by Wiley Periodicals, Inc. on behalf of International Society of Medicine in Resonance. PMID:24753130

  16. Avaliação da perfusão e função miocárdicas em vítimas de escorpionismo utilizando o Gated-SPECT Evaluación de la perfusión y función miocárdicas en víctimas de escorpionismo utilizando el Gated-SPECT Assessment of myocardial perfusion and function in victims of scorpion envenomation using Gated-SPECT

    Directory of Open Access Journals (Sweden)

    Alexandre Baldini de Figueiredo

    2010-04-01

    are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. OBJECTIVE: To investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. METHODS: Fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent and motion score (0 = normal, 4 = akinesia, using the 17-segment model. Summed perfusion (SPS and summed motion (SMS scores were calculated for each patient. Ejection fraction (LVEF was calculated by a commercially available software. RESULTS: At baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 ± 7.3, 17.0 ± 12.8, and 44.6 ± 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005 and negative correlation between SPS and LVEF (r = -0.75; p = 0.0021 were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 ± 9.5, p = 0.0002, segmental contractility (SMS of 2.6 ± 3.1, p = 0.0009 and perfusion (SPS of 3.7 ± 3.3, p = 0.0003. Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035. CONCLUSIONS: Myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (Arq Bras Cardiol 2010;94(4: 418-425

  17. Association between left ventricular perfusion defects and myocardial deformation indexes in heart transplantation recipients.

    Science.gov (United States)

    D'Andrea, Antonello; De Rimini, Maria Luisa; America, Raffaella; Cirillo, Chiara; Riegler, Lucia; Limongelli, Giuseppe; D'Alto, Michele; Salerno, Gemma; Maiello, Ciro; Muto, Pietro; Russo, Maria Giovanna; Calabrò, Raffaele; Bossone, Eduardo; Pacileo, Giuseppe

    2017-10-01

    The aim of the study was to analyze possible correlations between strain echocardiography (STE) and PET myocardial perfusion in a population of heart transplantation (HTx) recipients showing preserved left ventricular (LV) ejection fraction. By STE, LV global longitudinal strain (LV GLS) was lower in HTx. PET showed no transient or chronic ischemia in 83 of 115 HTx (73%). Fixed perfusion defects were observed in 17% of HTx and reversible ischemia in 10%. Significant coronary stenosis was observed only in 10 cases. GLS was independently associated with age at HTx and fixed perfusion defects (HR 0.41; P<.001). Such relationships underline STE ability to early identify HTx pts with subclinical myocardial dysfunction during long-term follow-up. © 2017, Wiley Periodicals, Inc.

  18. Does Enhanced External Counterpulsation (EECP Significantly Affect Myocardial Perfusion?: A Systematic Review & Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Xiaoxia Qin

    Full Text Available Enhanced external counterpulsation (EECP is currently applied for treating coronary artery disease (CAD patients. However, the mechanism(s by which EECP ameliorates angina pectoris and long-term left ventricular function remain largely unknown. The aim of this study will be to assess whether EECP significantly affects myocardial perfusion in CAD patients through a systematic review and meta-analysis of the available literature.MEDLINE, EMBASE, and Cochrane CENTRAL databases were searched for prospective studies on CAD patients that underwent EECP and reported myocardial perfusion data pre- and post-EECP. The impact of EECP was assessed based on the weighted mean difference (WMD in myocardial perfusion from pre-EECP to post-EECP. Statistical heterogeneity was assessed by the I2 index. Publication bias was assessed through visual inspection of the funnel plot as well as Begg's and Egger's testing.Standard EECP therapy (i.e., 35-36 one-hour sessions within a seven-week period significantly increased myocardial perfusion in CAD patients (pooled WMD: -0.19, 95% CI: -0.38 to 0.00, p = 0.049. A random effects analysis was applied on account of significant heterogeneity (I2 = 89.1%, p = 0.000. There was no evidence of significant publication bias (Begg's p = 0.091; Egger's p = 0.282.Standard EECP therapy significantly increases myocardial perfusion in CAD patients. This study's findings support the continued use of standard EECP therapy in CAD patients and provides one putative physiological mechanism to help explain the improvements in angina pectoris and long-term left ventricular function observed in CAD patients after EECP therapy.

  19. Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Shigeru; Furui, Shigeru; Kaminaga, Tatsuro; Miyazawa, Akiyoshi; Ueno, Yasunari; Konno, Kumiko [Teikyo University School of Medicine, Tokyo (Japan); Kuwahara, Sadatoshi; Mehta, Dhruv [Philips Electronics Japan, Ltd. Medical Systems, Tokyo (Japan)

    2009-06-15

    We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans. As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen. The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error. The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution.

  20. Protective effect of active perfusion in porcine models of acute myocardial ischemia.

    Science.gov (United States)

    Feng, Zanxiang; Mao, Zhifu; Dong, Shengjun; Liu, Baohui

    2016-10-01

    Mortality rates associated with off‑pump coronary artery bypass (CAB) are relatively high, as the majority of patients requiring CAB are at a high risk for cardiac events. The present study aimed to establish porcine models of acute myocardial ischemia, and evaluate the protective role of shunt and active perfusion. A total of 30 pigs were randomly assigned to five groups, as follows: i) Sham (control); ii) A1 (shunt; stenosis rate, 55%); iii) A2 (shunt; stenosis rate, 75%); iv) B1 (active perfusion; stenosis rate, 55%); and v) B2 (active perfusion; stenosis rate, 75%) groups. Aortic pressure (P0), left anterior descending coronary pressure (P1), and coronary effective perfusion pressure (P1/P0) were measured. The expression levels of tumor necrosis factor‑α (TNF‑α), cardiac troponin (cTnI), creatine kinase‑myocardial band (CK‑MB), interleukin (IL)‑6, IL‑10, B‑cell lymphoma 2 (Bcl‑2), and caspase‑3 were detected using enzyme‑linked immunosorbent assay or western blotting. The myocardial apoptosis rate was determined using the terminal deoxynucleotidyl transferase dUTP nick end labeling assay. Ischemia models with stenosis rates of 55 and 75% were successfully constructed following suturing of the descending artery. Compared with the control, the 55 and 75% stenosis groups demonstrated significantly decreased P1/P0, increased expression levels of TNF‑α, cTnI, CK‑MB, IL‑6, IL‑10 and caspase‑3, an increased rate of myocardial apoptosis, and a decreased expression level of anti‑apoptotic protein, Bcl‑2. At 30 min following successful establishment of the model (ST segment elevation to 1 mm), group B demonstrated significantly increased P1/P0, decreased expression levels of TNF‑α, cTnI, CK‑MB, IL‑6, IL‑10 and caspase‑3, a decreased rate of myocardial apoptosis, and an increased expression level of anti-apoptotic protein, Bcl‑2. Furthermore, the current study indicated that active perfusion was more efficacious

  1. Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Isola, A A [Philips Research Laboratories, X-ray Imaging Systems Department, Weisshausstrasse 2, D-52066 Aachen (Germany); Schmitt, H; Van Stevendaal, U; Grass, M [Philips Research Laboratories, Sector Digital Imaging, Roentgenstrasse 24-26, D-22335 Hamburg (Germany); Begemann, P G [Department of Radiology, University Hospital Hamburg-Eppendorf, Martinistrasse 52, D-20246 Hamburg (Germany); Coulon, P [Philips Healthcare France, 33 rue de Verdun, F-92150 Suresnes Cedex (France); Boussel, L, E-mail: Alfonso.Isola@Philips.com [Department of Radiology, Louis Pradel Hospital, CREATIS, UMR CNRS 5515, INSERM U630, Lyon (France)

    2011-09-21

    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.

  2. Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT

    Science.gov (United States)

    Isola, A. A.; Schmitt, H.; van Stevendaal, U.; Begemann, P. G.; Coulon, P.; Boussel, L.; Grass, M.

    2011-09-01

    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.

  3. Diabetes patients show different time-course of myocardial perfusion improvement after coronary artery bypass grafting

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. J.; Seok, J. W.; Eo, J. S. [Seoul National University Hospital, Seoul (Korea, Republic of)] (and others)

    2005-07-01

    Diabetes mellitus is an independent risk factor of cardiovascular disease. Diabetes is known to cause microangiopathy. The microangiopathy is hardly detectable on the coronary angiography. Myocardial perfusion imaging shows the resultant perfusion status which reflects the microangiopathy. For patients who underwent revascularization, the microangiopathy could affect the myocardial perfusion improvement. Diabetes patients probably experience the different myocardial perfusion improvement as compared to the non-diabetes patients although they have similar angiographic findings. The aim of this study is to find out whether there is a time-course difference of perfusion improvement between the diabetes and non diabetes patients who showed patent angiographic findings after coronary artery grafting surgery (CABG). A total of 129 patients who underwent coronary artery bypass grafting surgery were enrolled in this study. Myocardial SPECTs performed at previous, short-term (3 month), and mid-term (1 year) to CABG. One-year follow up angiography was done 411{+-}121 days after surgery. Graft patency was determined according to the FitzGibbon et al. Segments were assigned to vascular territories using a 20 segment model. The segments of excellent patency were included in this study. Time course differences of concerned segments were analyzed using RMANOVA. The number of segments enrolled was 764 of diabetes and 1083 of non-diabetes. At short-term follow up, reversibility score was 2.8{+-}8.1% in diabetes and 0.3{+-}7.5% in non-diabetes. At long-term follow up, reversibility score was 1.8{+-}8.0% in diabetes and 0.1{+-}7.3% in non-diabetes. The time-course of reversibility score was significantly different between the diabetes and non diabetes (p<0.001) Diabetic segments showed high residual reversibility score than non-diabetic segments after CABG although the angiographic finding was patent in both groups. This result is maybe attributable to microangiopathy induced by

  4. Coronary artery aneurysm and type-A aortic dissection demonstrated by retrospectively ECG-gated multislice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Fallenberg, Eva Maria; Juergens, Kai Uwe; Fischbach, Roman [Department of Clinical Radiology, University Hospital Muenster (Germany); Wichter, Thomas [Department of Cardiology and Angiology, University Hospital Muenster (Germany); Scheld, Hans H. [Department of Thoracic and Cardiovascular Surgery, University Hospital Muenster (Germany)

    2002-01-01

    The case of a 40-year-old male patient with a coronary aneurysm of the proximal left descending artery (LAD) combined with circumferential type-A dissection of the ascending aorta is reported. Computed tomography angiography of the coronary arteries was performed using multislice spiral computed tomography (MSCT) with retrospective ECG gating. Anatomical relations of the LAD aneurysm as well as the origin of the left coronary artery from the false lumen of the dissection were well depicted for planning of the surgical intervention using this new noninvasive imaging modality. (orig.)

  5. Impact of ECG gating in contrast-enhanced MR angiography for the assessment of the pulmonary veins and the left atrium anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, M.; Buecker, A.; Muehlenbruch, G.; Guenther, R.W.; Spuentrup, E. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum RWTH Aachen (Germany); Schauerte, P. [Medizinische Klinik 1, Universitaetsklinikum RWTH Aachen (Germany)

    2006-02-15

    Purpose: Implementation of ECG gating in contrast-enhanced MR angiography (ceMRA) for improved visualization of the pulmonary veins, the left atrium, and the thoracic vessels. Materials and Methods: CeMRA was performed on twelve patients with a history of recurrent atrial fibrillation for the purpose of an intra-individual comparison with and without ECG gating on a 1.5 Tesla MR system (Gyroscan Intera, Philips Medical Systems, Best, NL). Objective image quality parameters such as the signal-to-noise ratio (SNR) of the blood and the contrast-to-noise ratio (CNR) between the blood and myocardium or lung parenchyma were analyzed. The contour sharpness of the pulmonary veins, left atrium, ascending aorta, and pulmonary trunk was also measured. In addition, the artifact level was subjectively assessed by two observers blinded with respect to the sequence parameters. Statistically significant differences (p<0.05) between the procedures were analyzed using the Wilcoxon test and Pearson Chi-square test. Results: The use of ECG gating in ceMRA significantly reduced artifacts caused by cardiac motion and vessel pulsation. This in turn lead to a significant increase in the contour sharpness of the left atrium and the thoracic vessels. In addition, higher SNR and CNR were found using ECG-gated ceMRA compared to standard ceMRA. Conclusion: The use of ECG gating in ceMRA results in artifact-free and sharper delineation of the structures of the heart and thoracic vessels. (orig.)

  6. Impact of acute propranolol administration on dobutamine-induced myocardial ischemia as evaluated by myocardial perfusion imaging and echocardiography.

    Science.gov (United States)

    Shehata, A R; Gillam, L D; Mascitelli, V A; Herman, S D; Ahlberg, A W; White, M P; Chen, C; Waters, D D; Heller, G V

    1997-08-01

    Beta-blocker therapy may delay or completely prevent myocardial ischemia during exercise testing, as assessed by ST-segment shifts, myocardial perfusion defects, or echocardiographic wall motion abnormalities. However, the impact of beta-blocker therapy on these end points during dobutamine stress testing has not been well established. The purpose of this study was to determine the impact of propranolol on dobutamine stress testing with ST-segment monitoring, technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) imaging, and echocardiography. In 17 patients with known reversible perfusion defects, dobutamine stress tests with and without propranolol were performed in randomized order and on separate days, following discontinuation of oral beta blockers and calcium antagonists. Propronolol was administered intravenously to a cumulative dose of 8 mg or to a maximum heart rate reduction of 25% and dobutamine was infused in graded doses in 3 minute stages until a standard clinical end point or the maximum dose of 40 microg/kg/min was achieved. The dobutamine stress test after propranolol was associated with a lower maximum heart rate (83 +/- 18 vs 125 +/- 17, p <0.001) and rate pressure product (14,169 +/- 4,248 vs 19,894 +/- 3,985, p <0.001) despite a higher infusion dose. The SPECT myocardial ischemia score was also lower (6.9 +/- 5.8 vs 10.1 +/- 7.1, p = 0.047) and fewer echocardiographic segments were abnormal (3.4 +/- 3.0 vs 4.6 +/- 3.4, p = 0.042). In 4 of 17 patients, reversible perfusion defects and echocardiographic wall motion abnormalities were detected during the control but not during the propranolol test. Thus, during dobutamine stress testing, beta-blocker therapy attenuates, and in some cases eliminates, evidence of myocardial ischemia.

  7. Diagnostic Accuracy of Stress Myocardial Perfusion Imaging Compared to Invasive Coronary Angiography With Fractional Flow Reserve Meta-Analysis

    NARCIS (Netherlands)

    Takx, Richard A. P.; Blomberg, Bjorn A.; El Aidi, Hamza; Habets, Jesse; de Jong, Pim A.; Nagel, Eike; Hoffmann, Udo; Leiner, Tim

    2015-01-01

    Background-Hemodynamically significant coronary artery disease is an important indication for revascularization. Stress myocardial perfusion imaging is a noninvasive alternative to invasive fractional flow reserve for evaluating hemodynamically significant coronary artery disease. The aim was to det

  8. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography

    DEFF Research Database (Denmark)

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard

    2015-01-01

    To assess the relationship between epicardial coronary artery stenosis severity and the corresponding regional transmural perfusion at rest and during adenosine stress, using multidetector computed tomography (MDCT). We evaluated the relationship between the severity of coronary artery diameter...... = stress - PI/rest - PI), and the transmural perfusion ratio (TPR = subendocardium/subepicardium) were calculated. A coronary artery stenosis ≥50 % was present in 49 patients (25 %). Rest-PI and rest-TPR values were similar in patients with and without a coronary artery stenosis ≥50 %, whereas stress...... stenosis assessed by MDCT angiography and semi-quantitative myocardial MDCT perfusion in 200 symptomatic patients. The perfusion index (PI = mean myocardial attenuation density/mean left ventricular lumen attenuation density) at rest and during adenosine stress, the myocardial perfusion reserve (MPR...

  9. A stepwise approach to the visual interpretation of CT-based myocardial perfusion.

    Science.gov (United States)

    Mehra, Vishal C; Valdiviezo, Carolina; Arbab-Zadeh, Armin; Ko, Brian S; Seneviratne, Sujith K; Cerci, Rodrigo; Lima, Joao A C; George, Richard T

    2011-01-01

    Cardiovascular anatomic and functional testing have been longstanding and key components of cardiac risk assessment. As part of that strategy, CT-based imaging has made steady progress, with coronary computed tomography angiography (CTA) now established as the most sensitive noninvasive strategy for assessment of significant coronary artery disease. Myocardial CT perfusion imaging (CTP), as the functional equivalent of coronary CTA, is being tested in currently ongoing multicenter trials and is proposed to enhance the accuracy of coronary CTA alone. However, unlike coronary CTA that has published guidelines for interpretation and is rapidly gaining applicability in the noninvasive risk assessment paradigms, myocardial CTP is rapidly evolving, and guidance on a standard approach to its interpretation is lacking. In this article we describe a practical stepwise approach for interpretation of myocardial CTP that should add to the clinical applicability of this modality. These steps include (1) coronary CTA interpretation for potentially obstructive atherosclerosis, (2) reconstruction and preprocessing of myocardial CTP images, (3) image quality assessment and the identification of potentially confounding artifacts, (4) rest and stress image interpretation for enhancement patterns and areas of hypoattenuation, and (5) correlation of coronary anatomy and myocardial perfusion deficits. This systematic review uses already published methods from multiple clinical studies and is intended for general usage, independent of the platform used for image acquisition.

  10. Translational Medicine Study on Cardiac Microvascular Endothelial Barrier Function and Myocardial Ischemia/Re-perfusion Injury

    Institute of Scientific and Technical Information of China (English)

    Yeong Yeh Lee

    2015-01-01

    Vascular endothelial barrier is defined as the ability of endothelial cells and their components that make up the microvascular wall structure in controlling the cellular components and marco-molecular substances in blood from penetrating vascular walls. It is the place for the selective exchange of oxygen, nutrients and metabolites, and has kernel effect in maintaining myocardial micro-environmental homeostasis. In clinic, microvascular permeability is commonly used as the index for evaluating endothelial barrier function. Myocardial microvascular endothelial cells, inter-endothelial connexin and basilar membrane (BM) interact synergically to constitute the basis for barrier function, which has a selective permeability effect on interaction between nutrient substances and other myocardial cell molecules. Increase of microvascular permeability is closely associated with cardiovascular events like coronary heart disease (CHD) and myocardial ischemia, and is the risk factor for CHD attack. And deep exploration of the mechanism of endothelial permeability and positive selection of new-type re-perfusion complementary drugs for alleviating endothelial permeability can be beneifcial in improving the prognosis of patients with acute myocardial infarction (AMI). Therefore, from the view of translational medicine, this study mainly summarized the increase of microvascular permeability and its pathological signiifcance after AMI, physiological and pathological mechanisms of regulating microvascular permeability and complementary therapies for AMI re-perfusion as well as microvascular endothelial barrier function, hoping to provide a basis for improving the prognosis of patients with AMI.

  11. Translational Medicine Study on Cardiac Microvascular Endothelial Barrier Function and Myocardial Ischemia/Re-perfusion Injury

    Directory of Open Access Journals (Sweden)

    Yeong Yeh Lee

    2015-09-01

    Full Text Available Vascular endothelial barrier is defined as the ability of endothelial cells and their components that make up the microvascular wall structure in controlling the cellular components and marco-molecular substances in blood from penetrating vascular walls. It is the place for the selective exchange of oxygen, nutrients and metabolites, and has kernel effect in maintaining myocardial micro-environmental homeostasis. In clinic, microvascular permeability is commonly used as the index for evaluating endothelial barrier function. Myocardial microvascular endothelial cells, inter-endothelial connexin and basilar membrane (BM interact synergically to constitute the basis for barrier function, which has a selective permeability effect on interaction between nutrient substances and other myocardial cell molecules. Increase of microvascular permeability is closely associated with cardiovascular events like coronary heart disease (CHD and myocardial ischemia, and is the risk factor for CHD attack. And deep exploration of the mechanism of endothelial permeability and positive selection of new-type re-perfusion complementary drugs for alleviating endothelial permeability can be beneficial in improving the prognosis of patients with acute myocardial infarction (AMI. Therefore, from the view of translational medicine, this study mainly summarized the increase of microvascular permeability and its pathological significance after AMI, physiological and pathological mechanisms of regulating microvascular permeability and complementary therapies for AMI re-perfusion as well as microvascular endothelial barrier function, hoping to provide a basis for improving the prognosis of patients with AMI.

  12. Effects of diltiazem on myocardial perfusion abnormalities during exercise in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Hiroki; Taniguchi, Yoko; Ito, Kazuki [Kyoto Prefectural Univ. of Medicine (Japan)] [and others

    1998-12-01

    The effect of diltiazem on myocardial ischemia in patients with hypertrophic cardiomyopathy (HCM) was evaluated by exercise myocardial {sup 201}Tl single photon emission computed tomography (SPECT). Exercise myocardial SPECT was performed before and 8 weeks after oral administration of diltiazem (180 mg/day) in 20 patients with HCM who showed transient perfusion defects on exercise myocardial {sup 201}Tl SPECT under control conditions. SPECT images were divided into 17 segments. The {sup 201}Tl perfusion defects were visually scored and evaluated as the defect score. The transient dilation index was calculated as an index of subendocardial ischemia. Improvement of the defect score was demonstrated in 15 patients after the administration of diltiazem. The mean defect score decreased significantly from 9.90{+-}5.17 to 5.50{+-}4.89 (p<0.0001). Although 16 of 20 patients showed an abnormal transient dilation index before diltiazem treatment, 16 showed improvement and 13 of these normalized after diltiazem therapy. The mean transient dilation index decreased from 1.16{+-}0.10 to 1.02{+-}0.09 (p<0.0001). In conclusion, diltiazem prevents or diminishes myocardial ischemia in patients with HCM. (author)

  13. Intermodel Agreement of Myocardial Blood Flow Estimation From Stress-Rest Myocardial Perfusion Magnetic Resonance Imaging in Patients With Coronary Artery Disease

    NARCIS (Netherlands)

    Handayani, Astri; Triadyaksa, Pandji; Dijkstra, Hildebrand; Pelgrim, Gert Jan; van Ooijen, Peter M. A.; Prakken, Niek H. J.; Schoepf, U. Joseph; Oudkerk, Matthijs; Vliegenthart, Rozemarijn; Sijens, Paul E.

    2015-01-01

    Objectives: The aim of this study was to assess the intermodel agreement of different magnetic resonance myocardial perfusion models and evaluate their correspondence to stenosis diameter. Materials and Methods: In total, 260 myocardial segments were analyzed from rest and adenosine stress first-pas

  14. The additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress cardiac MRI for the detection of myocardial ischemia

    NARCIS (Netherlands)

    Lubbers, Daniel D.; Janssen, Caroline H. C.; Kuijpers, Dirkjan; Van Dijkman, Paul R. M.; Overbosch, Jelle; Willems, Tineke P.; Oudkerk, Matthijs

    2008-01-01

    Purpose of this study was to assess the additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress Cardiac-MR (CMR). Dobutamine Stress CMR was performed in 115 patients with an inconclusive diagnosis of myocardial ischemia on a 1.5 T system (Magnetom Avanto, Si

  15. Evaluation of regional work from ECG-gated SPECT images through solution of equations of continuity for fluids-mechanical cardiac work calculated using thin wall model.

    Science.gov (United States)

    Maeda, Hisatoshi

    2012-03-01

    Regional contraction work (RCW) of left ventricle (LV) was evaluated from cardiac perfusion images of ECG-gated single photon emission computed tomography (ECG-SPECT). The mechanical work was computed as a product of force and displaced distance. Force was determined from Laplace's law under a rectangle pressure. Deformation of wireframe representing LV was calculated from equations of continuity for two-dimensional fluids. Experiments were performed with homemade life-sized cardiac models. Total contraction work (TCW) and stroke work (SW) were 524.0 ± 166.1 mJ/beat and 709.8 ± 169.5 mJ/beat, respectively, in normal subjects (n = 23). Moderate correlation was seen between TCW and SW (y = -43.4 + 0.779 x, r = 0.815). The regional contraction amplitude (RCA), synchronous contraction index and RCW were 35.4 ± 3.5%, 95.4 ± 3.1% and 5.58 ± 0.97 mJ cm(-2)/beat in normal subjects, whereas those in patients with decreased ejection raction (EF) ≤ 30% (n = 6) were 19.6 ± 7.7%, 64.4 ± 32.2% and 2.58 ± 0.82 mJ cm(-2)/beat (p < 0.0001, Student's t-test). There was a poor correlation between RCW and RCA (y = 1.648 ± 0.116 x, r = 0.501) in normal subjects, suggesting that it might not be suitable to use RCA as an alternative to evaluate RCW.

  16. Use of neural networks to improve quality control of interpretations in myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Tagil, K.; Marving, J.; Lomsky, M.

    2008-01-01

    ). METHODS: Reversible perfusion defects (ischaemia) in each of five myocardial regions, as interpreted by one experienced nuclear medicine physician during his daily routine of clinical reporting, were assessed by artificial neural networks in 316 consecutive patients undergoing stress/rest 99m...... cases. Forty-six of the 53 cases (87%) came from the group selected by the neural networks, and only seven (13%) were control cases (P medicine expert and artificial networks were related to small and mild......BACKGROUND: The aim of this study was to explore the feasibility of using a technique based on artificial neural networks for quality assurance of image reporting. The networks were used to identify potentially suboptimal or erroneous interpretations of myocardial perfusion scintigrams (MPS...

  17. Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study

    Directory of Open Access Journals (Sweden)

    Pohost Gerald M

    2008-12-01

    Full Text Available Abstract Background In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D and of two dimensional (2D multi-slice myocardial perfusion imaging (MPI using cardiovascular magnetic resonance (CMR in determining the size of defects, and to demonstrate the feasibility of 3D MPI in healthy volunteers at 3 Tesla. Methods A heart phantom was used to compare the accuracy of 3D and 2D multi-slice MPI in estimating the volume fraction of seven rubber insets which simulated transmural myocardial perfusion defects. Three sets of cross-sectional planes were acquired for 2D multi-slice imaging, where each set was shifted along the partition encoding direction by ± 10 mm. 3D first-pass contrast-enhanced (0.1 mmol/kg Gd-DTPA MPI was performed in three volunteers with sensitivity encoding for six-fold acceleration. The upslope of the myocardial time-intensity-curve and peak SNR/CNR values were calculated. Results Mean/standard deviation of errors in estimating the volume fraction across the seven defects were -0.44/1.49%, 2.23/2.97%, and 2.59/3.18% in 3D, 2D 4-slice, and 2D 3-slice imaging, respectively. 3D MPI performed in healthy volunteers produced excellent quality images with whole left ventricular (LV coverage. Peak SNR/CNR was 57.6 ± 22.0/37.5 ± 19.7 over all segments in the first eight slices. Conclusion 3D performed better than 2D multi-slice MPI in estimating the size of perfusion defects in phantoms. Highly accelerated 3D MPI at 3T was feasible in volunteers, allowing whole LV coverage with excellent image quality and high SNR/CNR.

  18. Stress Myocardial Perfusion Imaging in the Emergency Department - New Techniques for Speed and Diagnostic Accuracy

    OpenAIRE

    Harrison, Sheri D; Harrison, Mark A; Duvall, W. Lane

    2012-01-01

    Emergency room evaluations of patients presenting with chest pain continue to rise, and these evaluations which often include cardiac imaging, are an increasing area of resource utilization in the current health system. Myocardial perfusion imaging from the emergency department remains a vital component of the diagnosis or exclusion of coronary artery disease as the etiology of chest pain. Recent advances in camera technology, and changes to the imaging protocols have allowed MPI to become a ...

  19. Assessment of Myocardial Perfusion and Systolic Function in Patients with Coronary Artery Disease after Coronary Artery Bypass Surgery by Myocardial Contrast Echocardiography and Two-dimensional Strain Echocardiography

    Institute of Scientific and Technical Information of China (English)

    Rong LIU; Youbin DENG; Xiaojun BI; Yani LIU; Li XIONG; Liuping CHEN

    2009-01-01

    The clinically applied value of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery using real-time myocardial contrast echo-cardiography (RT-MCE) combined with two-dimensional strain echocardiography was assessed.Twenty patients underwent intravenous RT-MCE by intravenous injections of Sono Vue before and after coronary artery bypass surgery. Two-dimensional images were recorded from the left ventricular four-chamber view, two-chamber view and the apical view before, and two weeks and three months af-ter coronary artery bypass surgery, and the peak systolic longitudinal strain was measured. The results showed that myocardial perfusion was significantly increased after coronary artery bypass surgery in about 71.6% segments. In the group that myocardial perfusion was improved, the peak systolic longitu-dinal strain three months after bypass surgery was significantly higher than that before operation [(-15.78±5.91)% vs (-10.45±8.31)%, P0.05]. It was con-cluded that whether or not the improvement of myocardial perfusion can mirror the recovery trend of regional systolic function, two-dimensional strain echocardiography can observe dynamic change of re-gional systolic function. The combination of myocardial perfusion with two-dimensional strain echocar-diography can more accurately assess the curative effectiveness of coronary artery bypass surgery.

  20. Reliability of myocardial perfusion quantification in angiography using a digital flat panel cardiac system

    Science.gov (United States)

    Perrin, Muriel; Vaillant, Regis; Gavit-Houdant, Laurence; Lienard, Jean; Benali, Karim

    2002-04-01

    Discordance between lesion severity from angiocardiography and physiological effects has been reported elsewhere. Quantification of myocardial perfusion during the angiography procedure may supply additional information about short- and long-term outcomes and may be helpful for clinical decision making. In previous works, myocardial perfusion has been assessed using time density curves (TDC), which represent the contrast medium dilution over time in the myocardium. The mean transit time (MTT), derived from the TDC, has been reported as a good indicator of the regional myocardial perfusion. Our objective is to estimate the accuracy and reproducibility of MTT estimation on digital flat panel (DFP) images. We have simulated typical myocardium TDC obtained with a DFP cardiac system (Innova 2000, GE), taking into account scatter and noise. Logarithmic or linear subtractions have been applied to derive a contrast medium concentration proportional quantity from image intensity. A non-linear minimisation realises the model curve fitting. MTT estimates are more stable with linear subtraction in presence of scatter. However logarithmic subtraction presents smaller bias when scatter level is small. Both approaches are equally sensible to image noise. Linear subtraction should be preferred. Image noise has a high influence on MTT accuracy and we may reduce.

  1. Risk assessment by myocardial perfusion imaging for coronary revascularization, medical therapy, and noncardiac surgery.

    Science.gov (United States)

    Papaioannou, Georgios I; Heller, Gary V

    2003-01-01

    Stress myocardial perfusion imaging (MPI) has become an important tool in risk stratification of patients with known coronary artery disease. A normal myocardial perfusion scan has a high negative predictive value and is associated with low annual mortality rate ( 20% of the left ventricle), defects in more than 1 coronary vascular territory, transient or persistent left ventricular cavity dilation, and ejection fraction less than 45% have a high annual mortality rate (> 3%). Those patients should undergo coronary revascularization whenever feasible, as the cardiac event rate increases in proportion to the magnitude of the jeopardized myocardium. Stress MPI can be used to demonstrate ischemia in patients with symptoms early after coronary artery bypass surgery (/= 5 years) after coronary artery bypass surgery. With respect to patients who underwent percutaneous interventions, stress MPI can help detect in-stent restenosis early after the intervention (3-6 months) or assess the progression of native coronary disease afterward. Since preliminary data suggest that a reduction in the perfusion defect size may translate to a reduction of coronary events, stress MPI can help assess the efficacy of medical management of coronary disease. Finally, stress MPI is indicated for perioperative cardiac risk stratification for noncardiac surgery in patients with intermediate risk predictors (mild angina, prior myocardial infarction or heart failure symptoms, diabetes mellitus, renal insufficiency) and poor functional capacity or in those who undergo high-risk surgery with significant implications in further preoperative management.

  2. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Cory V. [Baylor College of Medicine, Department of Pediatric Cardiology, Houston, TX (United States); Texas Children' s Hospital, Department of Pediatric Cardiology, Houston, TX (United States); Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Moffett, Brady [Texas Children' s Hospital, Department of Pharmacology, Houston, TX (United States)

    2017-03-15

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  3. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    ). Sensitivity and specificity were calculated with use of prespecified cutoffs. The reference standard was a stenosis of at least 50% at coronary angiography as determined with quantitative methods. RESULTS: CAD was diagnosed in 229 of the 381 patients (60%). The per-patient sensitivity and specificity......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography...... or pharmacologic stress SPECT before and within 60 days of coronary angiography. Images from CT perfusion imaging, SPECT, and coronary angiography were interpreted at blinded, independent core laboratories. The primary diagnostic parameter was the area under the receiver operating characteristic curve (Az...

  4. Outcome of patients with significant coronary stenosis but without ischemic evidence on exercise myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Ren; Toyama, Takuji; Sekiguchi, Makoto; Takama, Noriaki; Adachi, Hitoshi; Naito, Shigeto; Hoshizaki, Hiroshi; Oshima, Shigeru; Taniguchi, Koichi [Gunma Prefectural Cardiovascular Center, Maebashi (Japan)

    2001-03-01

    The rates of cardiac events and coronary revascularization were evaluated in patients with significant coronary stenosis of more than 75% by the American Heart Association (AHA) classification but no ischemic evidence by exercise myocardial perfusion scintigraphy. Subjects were 171 patients (113 males, 58 females, mean age 66{+-}9 years) undergoing coronary angiography and without scintigraphic evidence of myocardial ishemia. They were divided into two groups according to the severity of coronary artery stenosis based on AHA classification. Group A was composed of 139 patients with more than 75% stenosis (101 patients with 75% stenosis and 38 patients with more than 90% stenosis), and Group B was composed of 32 patients with 50% stenosis. Cardiac events including angina pectoris (n=63), myocardial infarction (n=1), heart failure (n=2) and cardiac death (n=0), coronary revascularization and predictive factors were evaluated during follow-up of 34{+-}21 months. Furthermore, the interval between coronary revascularization and exercise myocardial perfusion scintigraphy was estimated. The rates of cardiac events (45%) and coronary revascularization (29%) in Group A were significantly higher than the rate of cardiac events (9%, p<0.05) and coronary revascularization (6%, p<0.05) in Group B. Only percentage stenosis and the number of diseased vessels affected the rates of cardiac event and coronary revascularization. Patients with significant coronary stenosis, but without ischemic evidence by exercise myocardial perfusion scintigraphy, have a relatively high rate of cardiac event and coronary revascularization, especially in patients with severe stenosis or multivessel disease. However, coronary revascularization should not be performed in all patients with significant coronary stenosis. (author)

  5. Myocardial first-pass perfusion imaging with hybrid-EPI: frequency-offsets and potential artefacts

    Directory of Open Access Journals (Sweden)

    Ferreira Pedro F

    2012-06-01

    Full Text Available Abstract Background First-pass myocardial perfusion is often imaged with a tailored hybrid centric interleaved echo-planar-imaging sequence, providing rapid image acquisition with good contrast enhancement. The centric interleaved phase-encode order minimises the effective time-of-echo but it is sensitive to frequency-offsets. This short article aims to show possible artefacts that might originate with this sequence, in the context of first-pass perfusion imaging, when frequency-offsets are present. Non-uniform magnitude modulation effects were also analysed. Methods Numerical and phantom simulations were used to illustrate the effects of frequency-offsets and non-uniform magnitude modulation with this sequence in a typical perfusion protocol. In vivo data was post-processed to analyse the h-EPI’s sensitivity to the frequency-offsets. Results The centric phase-order was shown to be highly sensitive to frequency-offsets due to its symmetrical phase slope. Resulting artefacts include blurring, and splitting of the image into two identical copies along the phase-encode direction. It was also shown that frequency-offsets can introduce signal loss and ghosting of the right ventricle signal into the myocardium. The in vivo results were confirmed by numerical and phantom simulations. Magnitude modulation effects were found to be small. Conclusions Imaging first-pass myocardial perfusion with an hybrid centric echo-planar-imaging sequence can be corrupted with ghosting and splitting of the image due to frequency-offsets.

  6. Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia

    National Research Council Canada - National Science Library

    George, Richard T; Arbab-Zadeh, Armin; Miller, Julie M; Kitagawa, Kakuya; Chang, Hyuk-Jae; Bluemke, David A; Becker, Lewis; Yousuf, Omair; Texter, John; Lardo, Albert C; Lima, João A C

    2009-01-01

    .... However, in its current form, CTA is limited in its prediction of myocardial ischemia. The purpose of this study was to test whether adenosine stress computed tomography myocardial perfusion imaging (CTP...

  7. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Wang, G.J. [Brookhaven National Lab., Upton, NY (United States); Oster, Z.H. [State Univ. of New York, Stony Brook, NY (United States); Knapp, F.F. Jr. [Oak Ridge National Lab., TN (United States); Yonekura, Y. [Kyoto Univ. (Japan). Faculty of Medicine; Fujibayashi, Y. [Kyoto Univ. (Japan). Hospital; Yamamoto, K. [Fukui Univ. (Japan). Medical School; Kubota, K. [Tohoku Univ., Sendai (Japan)

    1992-12-31

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear. We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.

  8. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Wang, G.J. (Brookhaven National Lab., Upton, NY (United States)); Oster, Z.H. (State Univ. of New York, Stony Brook, NY (United States)); Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Yonekura, Y. (Kyoto Univ. (Japan). Faculty of Medicine); Fujibayashi, Y. (Kyoto Univ. (Japan). Hospital); Yamamoto, K. (Fukui Univ. (Japan). Medical School); Kubota, K. (Tohoku Univ., Sendai

    1992-01-01

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear. We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.

  9. Effects of pomegranate juice consumption on myocardial perfusion in patients with coronary heart disease.

    Science.gov (United States)

    Sumner, Michael D; Elliott-Eller, Melanie; Weidner, Gerdi; Daubenmier, Jennifer J; Chew, Mailine H; Marlin, Ruth; Raisin, Caren J; Ornish, Dean

    2005-09-15

    Pomegranate juice contains antioxidants such as soluble polyphenols, tannins, and anthocyanins and may have antiatherosclerotic properties. However, no study has investigated the effects of pomegranate juice on patients who have ischemic coronary heart disease (CHD). We investigated whether daily consumption of pomegranate juice for 3 months would affect myocardial perfusion in 45 patients who had CHD and myocardial ischemia in a randomized, placebo-controlled, double-blind study. Patients were randomly assigned into 1 of 2 groups: a pomegranate juice group (240 ml/day) or a placebo group that drank a beverage of similar caloric content, amount, flavor, and color. Participants underwent electrocardiographic-gated myocardial perfusion single-photon emission computed tomographic technetium-99m tetrofosmin scintigraphy at rest and during stress at baseline and 3 months. Visual scoring of images using standardized segmentation and nomenclature (17 segments, scale 0 to 4) was performed by a blinded independent nuclear cardiologist. To assess the amount of inducible ischemia, the summed difference score (SDS) was calculated by subtracting the summed score at rest from the summed stress score. The experimental and control groups showed similar levels of stress-induced ischemia (SDS) at baseline (p >0.05). After 3 months, the extent of stress-induced ischemia decreased in the pomegranate group (SDS -0.8 +/- 2.7) but increased in the control group (SDS 1.2 +/- 3.1, p pomegranate juice may improve stress-induced myocardial ischemia in patients who have CHD.

  10. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung [China Medical Coll., Taichung, Taiwan (China). Hospital; Wang, Jhi-Joung [Chi-Mei Medical Center, Tainan, Taiwan (China); Ho, Shung-Tai [National Defense Medical Center, Taipei, Taiwan (China). School of Medicine

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  11. Quantification of myocardial perfusion based on signal intensity of flow sensitized MRI

    Science.gov (United States)

    Abeykoon, Sumeda B.

    The quantitative assessment of perfusion is important for early recognition of a variety of heart diseases, determination of disease severity and their cure. In conventional approach of measuring cardiac perfusion by arterial spin labeling, the relative difference in the apparent T1 relaxation times in response to selective and non-selective inversion of blood entering the region of interest is related to perfusion via a two-compartment tissue model. But accurate determination of T1 in small animal hearts is difficult and prone to errors due to long scan times. The purpose of this study is to develop a fast, robust and simple method to quantitatively assess myocardial perfusion using arterial spin labeling. The proposed method is based on signal intensities (SI) of inversion recovery slice-select, non-select and steady-state images. Especially in this method data are acquired at a single inversion time and at short repetition times. This study began by investigating the accuracy of assessment of perfusion using a two compartment system. First, determination of perfusion by T1 and SI were implemented to a simple, two-compartment phantom model. Mathematical model developed for full spin exchange models (in-vivo experiments) by solving a modified Bloch equation was modified to develop mathematical models (T1 and SI) for a phantom (zero spin exchange). The phantom result at different flow rates shows remarkable evidence of accuracy of the two-compartment model and SI, T1 methods: the SI method has less propagation error and less scan time. Next, twelve healthy C57BL/6 mice were scanned for quantitative perfusion assessment and three of them were repeatedly scanned at three different time points for a reproducibility test. The myocardial perfusion of healthy mice obtained by the SI-method, 5.7+/-1.6 ml/g/min, was similar (p=0.38) to that obtained by the conventional T1 method, 5.6+/- 2.3 ml/g/min. The reproducibility of the SI method shows acceptable results: the

  12. A decision support system improves the interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Tagil, K.; Bondouy, M.; Chaborel, J.P.;

    2008-01-01

    PURPOSE: The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS). METHODS: Seven physicians independently...... interpreted 97 MPS studies, first without and then with the advice of a DSS. Four physicians had long experience and three had limited experience in the interpretation of MPS. Each study was interpreted regarding myocardial ischaemia and infarction in five myocardial regions. The patients had undergone...... from 81% without the DSS to 86% with the DSS (p = 0.01). The increase in sensitivity was higher for the three inexperienced physicians (9%) than for the four experienced physicians (2%). There was no significant change in specificity between the interpretations. The interpretations of ischaemia made...

  13. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy

    Directory of Open Access Journals (Sweden)

    Mohammad Eftekhari

    2015-01-01

    Full Text Available Objective(s: Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. Results: A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed and 36 patients with right-sided cancer (controls] were enrolled. Dose-volume histogram (DVH [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46. In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03 and anterolateral (17.1% versus 2.8%, P=0.049 walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS of>3 was observed in twelve cases (34.3%, while in five of the controls (13.9%,(Odds ratio=1.3. There was no significant difference between the groups regarding left ventricular ejection fraction. Conclusion: The risk of radiation induced myocardial

  14. Development of a theory for generating regional cardiac perfusion images during coronary angiography in the coronary angiography lab.

    Science.gov (United States)

    Sakaguchi, Takuya; Ichihara, Takashi; Trost, Jeffrey C; Yousuf, Omair; Lima, Joao A C; Yao, Jingwu; George, Richard T

    2014-01-01

    The purpose of this study was to develop a novel theory and method for generating regional myocardial perfusion images using fluoroscopy in the coronary angiography lab. We modified the Kety model to introduce the Patlak plot method for two-dimensional fluoroperfusion (FP) imaging. For evaluation, seven porcine models of myocardial ischemia with stenosis in the left coronary artery were prepared. Rest and stress FP imaging were performed using cardiovascular X-ray imaging equipment during the injection of iopamidol via the left main coronary artery. Images were acquired and retrospectively ECG gated at 80 % of the R-R interval. FP myocardial blood flow (MBF) was obtained using the Patlak plot method applied to time-intensity curve data of the proximal artery and myocardium. The results were compared to microsphere MBF measurements. Time-intensity curves were also used to generate color-coded FP maps. There was a moderate linear correlation between the calculated FP MBF and the microsphere MBF (y = 0.9758x + 0.5368, R² = 0.61). The color-coded FP maps were moderately correlated with the regional distribution of flow. This novel method of first-pass contrast-enhanced two-dimensional fluoroscopic imaging can quantify MBF and provide color coded FP maps representing regional myocardial perfusion.

  15. Assessment of microembolization associated with revascularization in acute myocardial infarction: MDCT cardiac perfusion and function study.

    Science.gov (United States)

    Saeed, Maythem; Hetts, Steven W; Do, Loi; Wilson, Mark W

    2013-12-01

    To use multi-detector computed tomography (MDCT) for assessing the effects of coronary microemboli on pre-existing acute myocardial infarct (AMI) and to compare this pathology to LAD microembolization and occlusion/reperfusion. An angioplasty balloon catheter was placed in the LAD coronary artery of pigs under X-ray guidance. Four animals served as controls without intervention (group A) and an additional 24 animals (8/group) were subjected to microembolization (group B), occlusion/reperfusion (group C) or combination of the two insults (group D). MDCT was used to assess perfusion, LV function and viability. At postmortem, the LV sections were stained with hematoxylin/eosin and triphenyltetrazolium chloride (TTC). Dynamic perfusion and helical cine MDCT demonstrated decline in regional LV perfusion and function, respectively, after all interventions. MDCT showed significant differences in ejection fraction between groups: A = 57.5 ± 4.7%, B = 40.3 ± 0.5% P 0.7). Microscopic examination confirmed the presence of patchy and contiguous necrosis, MVO, edema and calcium deposits. Dynamic and helical cine MDCT imaging can grade LV dysfunction and perfusion deficit, respectively. DE-MDCT demonstrated a large and persistent MVO zone after microembolization of pre-existing AMI. Furthermore, it has the potential to visualize patchy microinfarct, detect perfusion deficits and dysfunction at the border zone after microembolization of pre-existing AMI.

  16. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  17. Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients

    Energy Technology Data Exchange (ETDEWEB)

    Salem, Randa; Remy-Jardin, Martine; Delhaye, Damien; Khalil, Chadi; Teisseire, Antoine; Remy, Jacques [Hospital Calmette, University Center of Lille, Department of Thoracic Imaging, LILLE cedex (France); Delannoy-Deken, Valerie; Duhamel, Alain [University of Lille, Place de Verdun, Department of Medical Statistics, LILLE cedex (France)

    2006-09-15

    The purpose of this study was to investigate the possibility of assessing the underlying respiratory disease as well as cardiac function during ECG-gated CT angiography of the chest with 64-slice multidetector-row CT (MDCT). One hundred thirty-three consecutive patients in sinus rhythm with known or suspected ventricular dysfunction underwent an ECG-gated CT angiographic examination of the chest without {beta}-blockers using the following parameters: (1) collimation: 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices (Sensation 64; Siemens); rotation time: 0.33 s; pitch: 0.3; 120 kV; 200 mAs; ECG-controlled dose modulation (ECG-pulsing) and (2) 120 ml of a 35% contrast agent. Data were reconstructed: (1) to evaluate the underlying respiratory disease (1-mm thick lung and mediastinal scans reconstructed at 55% of the R-R interval; i.e., ''morphologic scans'') and (2) to determine right (RVEF) and left (LVEF) ventricular ejection fractions (short-axis systolic and diastolic images; Argus software; i.e., ''functional scans''). The mean heart rate was 73 bpm (range: 42-120) and the mean scan time was 18.11{+-}2.67 s (range: 10-27). A total of 123 examinations (92%) had both lung and mediastinal images rated as diagnostic scans, whereas 10 examinations (8%) had non-diagnostic images altered by the presence of respiratory-motion artifacts (n=4) or cyclic artifacts related to the use of a pitch value of 0.3 in patients with a very low heart rate during data acquisition (n=6). Assessment of right and left ventricular function was achievable in 124 patients (93%, 95% CI: 88-97%). For these 124 examinations, the mean RVEF was 46.10% ({+-}9.5; range: 20-72) and the mean LVEF was 58.23% ({+-}10.88; range: 20-83). In the remaining nine patients, an imprecise segmentation of the right and left ventricular cavities was considered as a limiting factor for precise calculation of end-systolic and end

  18. Quantification of left ventricular dilatation in myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Mauren B. Azambuja, E-mail: medicinanuclear@hsvp.com.b, E-mail: mauren.gonzalez@gmail.co [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Clinica Medica. Programa de Pos-Graduacao em Medicina e Ciencias da Saude; Azambuja, Roberto Alves [Hospital Sao Vicente de Paulo, Passo Fundo, RS (Brazil); Bodanese, Luiz Carlos [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil). Hospital Sao Lucas. Serv. de Cardiologia

    2011-05-15

    Background: the rate of transient dilatation can be determined by exercise testing or pharmacological stress test. It is unknown whether the type of stress has an impact on average transient dilatation index values. Objective: to compare average transient dilation index values in 99mTc-sestamibi scintigraphy in patients undergoing treadmill stress test, versus dipyridamole stress test. The secondary purpose was to evaluate the impact on the average index value by demographic characteristics, risk factors for coronary artery disease and severity of ischemia. Methods: the cross-sectional study included 200 patients between 40 and 70 years old, with or without risk factors for ischemic heart disease, with or without a previous diagnosis of ischemic heart disease. The separation between groups was sequential. The software 4D-MSPECT calculated the transient dilatation index and provided a scoring system for perfusion analysis. Results: the average transient dilation index value of the group undergoing exercise stress test was 1.06 ({+-}0.23). For the group undergoing the dipyridamole stress test, it was 1.10 ({+-}0.22); (p = 0.200). There was no association between the type of stress and the average transient dilatation index values. An association was found between the average index values and age only for those patients from the exercise test group (p = 0.009). Conclusion: the results of our study demonstrate that the transient dilation index does not differ when patients undergo exercise stress test on a treadmill or pharmacological stress by dipyridamole. (author)

  19. Quantitative Tc-99m myocardial perfusion SPECT with 180[degree] acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Ye, J.

    1992-01-01

    Myocardial perfusion single photon emission computed tomography (SPECT) images using 180[degrees] acquisition are degraded by the effects of scatter, nonuniform attenuation and system geometric resolution variation with source depth. Using a 180[degrees] scan orbit which is closer to the heart may provide higher image resolution, signal-to-noise ratio and defect-to-normal contrast than using a 360[degrees] orbit, however, significant object shape distortion has been observed in the 180[degrees] reconstructed images. A method has been developed that combines filtered back-projection (FBP) with iterative attenuation and three-dimensional (3-D) resolution compensation for Tc-99m myocardial perfusion imaging, data. The non-uniform attenuation coefficient distribution is obtained by a quick transmission scan using a flood source and segmentation of the reconstructed transmission image to define areas of significantly different attenuation. A priori attenuation coefficients are assigned to the areas to form the attenuation distribution map. The 3-D correction is accomplished by including both the non-uniform attenuation and depth-dependent resolution variation in the reprojection procedure of an iterative correction algorithm. The method was evaluated with both simulated and experimental data using clinical protocols with a cardiac phantom. A significant improvement in image resolution was observed with line source images was reduced from approximately 10 mm to 7.l5 mm after 7 iterations of the 3-D correction. The contrast of two perfusion defects to the surrounding normally perfused regions was significantly improved with the correction. Significant improvement in uniformity at different positions in the 100% perfused areas in the myocardium was also observed. The normalized root squared error (NRSE) of one transaxial image from the original source distribution in the simulation study was reduced from 0.8 to 0.2 after 5 iterations of the 3-D correction.

  20. Quality of myocardial perfusion single-photon emission tomography imaging: multicentre evaluation with a cardiac phantom.

    Science.gov (United States)

    Heikkinen, J; Ahonen, A; Kuikka, J T; Rautio, P

    1999-10-01

    The aim of the study was to evaluate quality of myocardial perfusion single-photon emission tomography (SPET) imaging in Finnish hospitals. Nineteen nuclear medicine departments participated in the study. A myocardial phantom simulating clinical stress and rest conditions was filled with routinely used isotope solution (technetium-99m or thallium-201). The cardiac insert included three reversible defects (simulating ischaemia): 30x30x14 mm(3) septal (90% recovery at rest), 30x20x14 mm(3) posterobasal (full recovery) and 20x20x14 mm(3) lateral (full recovery). There were two fixed defects (simulating infarct): 30x20x14 mm(3) postero-apical and 10x10x6 mm(3) apical. The phantom was imaged and interpreted as a myocardial perfusion patient. Reconstruction, printout and reporting were performed according to the clinical routine of each centre. Three nuclear medicine specialists anonymously evaluated the quality of the image sets. The visual scores of the experts were ranked from 1 to 5. Additionally, points from 0 to 8 were given to research reports according to how well perfusion defects were detected. Quantitative points were calculated by comparing background-subtracted and -normalized counts from 12 regions of interest between stress and rest images. Results for technetium studies (12 departments) were better than those for thallium (7 departments). The average visual scores of the experts were 3.7+/-0. 9 for all image sets, 3.2+/-0.5 for thallium users and 3.9+/-0.6 for technetium users (P=0.003). Five laboratories received a low score which, according to the specialists, is barely sufficient for limited clinical use. Average points for the reports were 5.6+/-2.1, 4.9+/-1.5 and 6.5+/-1.7 (P=0.051), and for the quantitation 8.2+/-1. 0, 7.9+/-0.4 and 8.4+/-1.1 (P=0.185), respectively. Seven out of 22 interpreters did not detect the lateral 20x20x14 mm(3) defect; five of them used thallium. This study demonstrated the heterogeneity of myocardial perfusion SPET in

  1. Quality of myocardial perfusion single-photon emission tomography imaging: multicentre evaluation with a cardiac phantom

    Energy Technology Data Exchange (ETDEWEB)

    Heikkinen, J. [Dept. of Nuclear Medicine, Etela-Savo Hospital District, Mikkeli Central Hospital, Mikkeli (Finland); Ahonen, A. [Dept. of Nuclear Medicine, Oulu University Hospital (Finland); Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio University Hospital and Niuvanniemi Hospital, Kuopio (Finland); Rautio, P. [Dept. of Clinical Physiology, North Karelia Central Hospital, Joensuu (Finland)

    1999-10-01

    The aim of the study was to evaluate quality of myocardial perfusion single-photon emission tomography (SPET) imaging in Finnish hospitals. Nineteen nuclear medicine departments participated in the study. A myocardial phantom simulating clinical stress and rest conditions was filled with routinely used isotope solution (technetium-99m or thallium-201). The cardiac insert included three reversible defects (simulating ischaemia): 30 x 30 x 14 mm{sup 3} septal (90% recovery at rest), 30 x 20 x 14 mm{sup 3} posterobasal (full recovery) and 20 x 20 x 14 mm{sup 3} lateral (full recovery). There were two fixed defects (simulating infarct): 30 x 20 x 14 mm{sup 3} postero-apical and 10 x 10 x 6 mm{sup 3} apical. The phantom was imaged and interpreted as a myocardial perfusion patient. Reconstruction, printout and reporting were performed according to the clinical routine of each centre. Three nuclear medicine specialists anonymously evaluated the quality of the image sets. The visual scores of the experts were ranked from 1 to 5. Additionally, points from 0 to 8 were given to research reports according to how well perfusion defects were detected. Quantitative points were calculated by comparing background-subtracted and -normalized counts from 12 regions of interest between stress and rest images. Results for technetium studies (12 departments) were better than those for thallium (7 departments). The average visual scores of the experts were 3.7{+-}0.9 for all image sets, 3.2{+-}0.5 for thallium users and 3.9{+-}0.6 for technetium users (P=0.003). Five laboratories received a low score which, according to the specialists, is barely sufficient for limited clinical use. Average points for the reports were 5.6{+-}2.1, 4.9{+-}1.5 and 6.5{+-}1.7 (P=0.051), and for the quantitation 8.2{+-}1.0, 7.9{+-}0.4 and 8.4{+-}1.1 (P=0.185), respectively. Seven out of 22 interpreters did not detect the lateral 20 x 20 x 14 mm{sup 3} defect; five of them used thallium. This study demonstrated

  2. Myocardial contrast echocardiography to assess perfusion in a mouse model of ischemia/reperfusion injury

    Science.gov (United States)

    Hossack, John A.; Li, Yinbo; Christensen, Jonathan P.; Yang, Zequan; French, Brent A.

    2004-04-01

    Noninvasive approaches for measuring anatomical and physiological changes resulting from myocardial ischemia / reperfusion injury in the mouse heart have significant value since the mouse provides a practical, low-cost model for modeling human heart disease. In this work, perfusion was assessed before, during and after an induced closed- chest, coronary ischemic event. Ultrasound contrast agent, similar to MP1950, in a saline suspension, was injected via cannulated carotid artery as a bolus and imaged using a Siemens Sequoia 512 scanner and a 15L8 intraoperative transducer operating in second harmonic imaging mode. Image sequences were transferred from the scanner to a PC for analysis. Regions of interest were defined in septal and anterior segments of the myocardium. During the ischemic event, when perfusion was diminished in the anterior segment, mean video intensity in the affected segment was reduced by one half. Furthermore, following reperfusion, hyperemia (enhanced blood flow) was observed in the anterior segment. Specifically, the mean video intensity in the affected segment was increased by approximately 50% over the original baseline level prior to ischemia. Following the approach of Kaul et al., [1], gamma variate curves were fitted to the time varying level of mean video intensity. This foundation suggests the possibility of quantifying myocardial blood flow in ischemic regions of a mouse heart using automated analysis of contrast image data sets. An improved approach to perfusion assessment using the destruction-reperfusion approach [2] is also presented.

  3. Investigation of the potential causes of partial scan artifacts in dynamic CT myocardial perfusion imaging

    Science.gov (United States)

    Tao, Yinghua; Speidel, Michael; Szczykutowicz, Timothy; Chen, Guang-Hong

    2014-03-01

    In recent years, there have been several findings regarding CT number variations (partial scan artifact or PSA) across time in dynamic myocardial perfusion studies with short scan gated reconstruction. These variations are correlated with the view angle range corresponding to the short scan acquisition for a given cardiac phase, which can vary from one cardiac cycle to another due to the asynchrony between heart rate and gantry rotation speed. In this study, we investigate several potential causes of PSA, including noise, beam hardening and scatter, using numerical simulations. In addition, we investigate partial scan artifact in a single source 64-slice diagnostic CT scanner in vivo data sets, and report its effect on perfusion analysis. Results indicated that among all three factors investigated, scatter can cause obvious partial scan artifact in dynamic myocardial perfusion imaging. Further, scatter is a low frequency phenomenon and is not heavily dependent on the changing contrasts, as both the frequency method and the virtual scan method are effective in reducing partial scan artifact. However, PSA does not necessarily lead to different blood volume maps compared to the full scan, because these maps are usually generated with a curve fitting procedure.

  4. 3D imaging of myocardial perfusion and coronary tree morphology from a single rotational angiogram

    Science.gov (United States)

    Lauritsch, Günter; Rohkohl, Christopher; Hornegger, Joachim; Sinha, Anil-Martin; Brachmann, Johannes; Rieber, Johannes; Rittger, Harald

    2011-03-01

    Diagnosis and treatment of coronary heart disease are performed in the catheter laboratory using an angiographic X-ray C-arm system. The morphology of the coronary tree and potentially ischemic lesions are determined in 2D projection views. The hemodynamic impact of the lesion would be valuable information for treatment decision. Using other modalities for functional imaging is disrupting the clinical workflow since the patient has to be transferred from the catheter laboratory to another scanner, and back to the catheter laboratory for performing the treatment. In this work a novel technology is used for simultaneous 3D imaging of first pass perfusion and the morphology of the coronary tree from a single rotational angiogram. A selective, single shot of contrast agent of less than 20ml directly into the coronaries is sufficient for a proper contrast resolution. Due to the long acquisition time cardiac motion has to be considered. A novel reconstruction technique for estimation and compensation of cardiac motion from the acquired projection data is used. The overlay of the 3D structure of the coronary tree and the perfusion image shows the correlation of myocardial areas and the associated coronary sections supporting that region. In a case example scar lesions caused by a former myocardial infarct are investigated. A first pass perfusion defect is found which is validated by a late enhancement magnetic resonance image. No ischemic defects are found. The non vital regions are still supported by the coronary vasculature.

  5. Identification of residual ischemia in the occluded coronary artery irrigation area using myocardial perfusion scintigraphy

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2007-01-01

    Full Text Available Background. Inspite the indisputable significance of coronarography, the implications of a revealed stenosis - and how close it is to occlusion could vary in regard to its physiological importance. Myocardial perfusion scintigraphy (MPS possibility to prove and objectivise the presence of ischemia and myocardial viability within an occlusion found coronarographically is especially significant since it makes possible to the clinician to choose an adequate therapy. Case report. We reported a 43- year-old male patient who had been hospitalized to another institution due to acute myocardial infarction (AMI of posterolateral localisation. Following the acute AMI stage the ergometric test per Bruce protocole was performed, negative to ischemic heart disease, while multislice computed tomography showed no significant changes on the coronary arteries. The performed one-day-protocole MPS showed a massive area of residual ischemia within myocardial infarction (MI type culprit lesion of the posterolateral zone starting from the subapical level to the basal cross-section. According to the MPS findings coronarography was indicated due to a revascularisation assessment. The performed coronarography revealed an occlusion of the circumflex coronary artery (CCA right after the division of obtuse branch (OB that presented discretely in the distal parts from the homo- and heterocolaterals. The distal portion of CCA presented discretely out off the right coronary artery (RCA. Echocardiography confirmed an ejection fraction of 50% with hypokinesia of inferior and posterior walls, as well as the septum, showing a mild reduction of the general contractility. Flows through confluences were well. A month after MI a percutane coronary intervention (PCI was performed with the implantation of a drug-releasing stent (Taxus. Early after PCI (within two weeks a control MPS was done to evaluate the effects of the therapy giving the normal findings of myocardial perfusion

  6. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    Directory of Open Access Journals (Sweden)

    Estêvan Vieira Cabeda

    2015-01-01

    Full Text Available AbstractBackground:Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB.Objective:To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA (stenosis ≥ 70% as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA and compare the results with those of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy.Methods:Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee.Results:The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001. The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001. In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001.Conclusion:The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

  7. Noninvasive evaluation of regional myocardial perfusion in 112 patients using a mobile scintillation camera and intravenous nitrogen-13 labeled ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, W.F.; Harper, P.V.; Resnekov, L.; Fill, H.

    1976-08-01

    The short half-life positron emitter /sup 13/N, as labeled ammonia (/sup 13/NH/sub 4//sup +/), was evaluated as a myocardial imaging agent. Regional myocardial uptake of /sup 13/NH/sub 4/ correlated with the distribution of labeled microspheres in experimental myocardial infarction. Using intravenous /sup 13/NH/sub 4//sup +/, myocardial scintigraphy was performed in 85 cardiac patients and 27 normal subjects. Ninety-five scintigrams were suitable for analysis. Eighteen of 24 normal subjects had homogeneous myocardial images; six had inhomogeneous images attributable to early technical problems. Perfusion defects were observed in the scintigrams of 82% (57/65) of patients with coronary artery disease, being most common in patients with myocardial infarction (27/28). Six sequential studies showed changes in perfusion consistent with the clinical course of each patient. Scintigraphic abnormalities were also observed in 4/6 patients with valvular heart disease. /sup 13/NH/sub 4//sup +/ myocardial scintigraphy is a valid and sensitive method of assessing regional myocardial perfusion and is especially useful for sequential imaging at short intervals.

  8. Evaluation of exposure dose reduction in multislice CT coronary angiography (MS-CTA) with prospective ECG-gated helical scan

    Science.gov (United States)

    Ota, Takamasa; Tsuyuki, Masaharu; Okumura, Miwa; Sano, Tomonari; Kondo, Takeshi; Takase, Shinichi

    2008-03-01

    A novel low-dose ECG-gated helical scan method to investigate coronary artery diseases was developed. This method uses a high pitch for scanning (based on the patient's heart rate) and X-rays are generated only during the optimal cardiac phases. The dose reduction was obtained using a two-level approach: 1) To use a 64-slice CT scanner (Aquilion, Toshiba, Otawara, Tochigi, Japan) with a scan speed of 0.35 s/rot. to helically scan the heart at a high pitch based on the patient's heart rate. By changing the pitch from the conventional 0.175 to 0.271 for a heart rate of 60 bpm, the exposure dose was reduced to 65%. 2) To employ tube current gating that predicts the timing of optimal cardiac phases from the previous cardiac cycle and generates X-rays only during the required cardiac phases. The combination of high speed scanning with a high pitch and appropriate X-ray generation only in the cardiac phases from 60% to 90% allows the exposure dose to be reduced to 5.6 mSv for patients with a heart rate lower than 65 bpm. This is a dose reduction of approximately 70% compared to the conventional scanning method recommended by the manufacturer when segmental reconstruction is considered. This low-dose protocol seamlessly allows for wide scan ranges (e.g., aortic dissection) with the benefits of ECG-gated helical scanning: smooth continuity for longitudinal direction and utilization of data from all cardiac cycles.

  9. Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring.

    Science.gov (United States)

    Pan, Zilai; Pang, Lifang; Li, Jianying; Zhang, Huan; Yang, Wenjie; Ding, Bei; Chai, Weimin; Chen, Kemin; Yao, Weiwu

    2011-04-01

    To evaluate the clinical value of a body mass index (BMI) based tube current (mA) selection method for obtaining consistent image quality with dose optimization in MDCT prospective ECG gated coronary calcium scoring. A formula for selecting mA to achieve desired image quality based on patient BMI was established using a control group (A) of 200 MDCT cardiac patients with a standard scan protocol. One hundred patients in Group B were scanned with this BMI-dependent mA for achieving a desired noise level of 18 HU at 2.5 mm slice thickness. The CTDIvol and image noise on the ascending aorta for the two groups were recorded. Two experienced radiologists quantitatively evaluated the image quality using scores of 1-4 with 4 being the highest. The image quality scores had no statistical difference (P = 0.71) at 3.89 ± 0.32, 3.87 ± 0.34, respectively, for groups A and B of similar BMI. The image noise in Group A had linear relationship with BMI. The image noise in Group B using BMI-dependent mA was independent of BMI with average value of 17.9 HU and smaller deviations for the noise values than in Group A (2.0 vs. 2.9 HU). There was a 35% dose reduction with BMI-dependent mA selection method on average with the lowest effective dose being only 0.35 mSv for patient with BMI of 18.3. A quantitative BMI-based mA selection method in MDCT prospective ECG gated coronary calcium scoring has been proposed to obtain a desired and consistent image quality and provide dose optimization across patient population.

  10. Reproducibility of aortic pulsatility measurements from ECG-gated abdominal CTA in patients with abdominal aortic aneurysms

    Science.gov (United States)

    Manduca, Armando; Fletcher, Joel G.; Wentz, Robert J.; Shields, Raymond C.; Vrtiska, Terri J.; Siddiki, Hassan; Nielson, Theresa

    2009-02-01

    Purpose: ECG-gated abdominal CT angiography with reconstruction of multiple, temporally overlapping CT angiography datasets has been proposed for measuring aortic pulsatility. The purpose of this work is to develop algorithms to segment the aorta from surrounding structures from CTA datasets across cardiac phases, calculate registered centerlines and measurements of regional aortic pulsatility in patients with AAA, and to assess the reproducibility of these measurements. Methods: ECG-gated CTA was performed with a temporal resolution of 165 ms, reconstructed to 1 mm slices ranging at 14 cardiac phase points. Data sets were obtained from 17 patients on which two such scans were performed 6 to 12 months apart. Automated segmentation, centerline generation, and registration of centerlines between phases was performed, followed by calculation of cross-sectional areas and regional and local pulsatility. Results: Pulsatility calculations for the supraceliac region were very reproducible between earlier and later scans of the same patient, with average differences less than 1% for pulsatility values ranging from 2% to 13%. Local radial pulsatilities were also reproducible to within ~1%. Aneurysm volume changes between scans can also be quantified. Conclusion: Automated segmentation, centerline generation, and registration of temporally resolved CTA datasets permit measurements of regional changes in cross-sectional area over the course of the cardiac cycle (i.e., regional aortic pulsatility). These measurements are reproducible between scans 6-12 months apart, with differences in aortic areas reflecting both aneurysm remodeling and changes in blood pressure. Regional pulsatilities ranged from 2 to 13% but were reproducible at the 1% level.

  11. Quantification of aortic distensibility in abdominal aortic aneurysm using ECG-gated multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ganten, Maria-Katharina [Deutsches Krebsforschungszentrum, Department of Radiology, Medical Physics in Radiology, Heidelberg (Germany); Ruprecht-Karls-University of Heidelberg, Department of Diagnostic Radiology, Heidelberg (Germany); Krautter, Ute; Tengg-Kobligk, Hendrik von; Delorme, Stefan; Kauczor, Hans-Ulrich [Deutsches Krebsforschungszentrum, Department of Radiology, Medical Physics in Radiology, Heidelberg (Germany); Boeckler, Dittmar; Schumacher, Hardy [Ruprecht-Karls-University of Heidelberg, Department of Vascular and Endovascular Surgery, Heidelberg (Germany); Stiller, Wolfram; Bock, Michael [Deutsches Krebsforschungszentrum, Department of Medical Physics in Radiology, Medical Physics in Radiology, Heidelberg (Germany); Kauffmann, Guenter W. [Ruprecht-Karls-University of Heidelberg, Department of Diagnostic Radiology, Heidelberg (Germany)

    2008-05-15

    To detect distensibility changes that might be an indicator for an increased risk of rupture, cross-sectional area changes of abdominal aortic aneurysms (AAA) have been determined using ECG-gated CT. Distensibility measurements of the aorta were performed in 67 patients with AAA. Time-resolved images were acquired with a four detector-row CT system using a modified CT-angiography protocol. Pulsatility-related cross-sectional area changes were calculated above and at AAA level by semiautomatic segmentation; distensibility values were obtained using additional systemic blood pressure measurements. Values were compared for small Oe< 5 cm (n=44) and large Oe> 5 cm (n = 23) aneurysms. The aorta could be segmented successfully in all patients. Upstream AAA distensibility D was significantly higher than at AAA level for both groups: means above AAA (at AAA) D{sub above} = (1.3 {+-}0.8) .10 {sup -5} Pa {sup -1} (D{sub AAA} = (0.6 {+-}0.5) .10 {sup -5} Pa {sup -1}) t-test p{sub D}<0.0001. Differences of the distensibility between smaller and larger aneurysms were not found to be significant. Distensibility can be measured non-invasively with ECG-gated CT. The reduction of distensibility within aneurysms compared to normal proximal aorta is subtle; the lack of difference between both small and large aneurysms suggests that this reduction occurs early in the aneurysm's development. Hence, reduced distensibility might be a predictive parameter in patients with high risk of aortic disease. (orig.)

  12. Tc{sup 99m}-sestamibi dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno M.; Campos, Tarcisio P.R., E-mail: janine.toledo@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear. Programa de Pos-Graduaco em Ciencias e Tecnicas Nucleares

    2015-07-01

    This paper addressed myocardial perfusion imaging providing a spatial dosimetric investigation of the {sup 99m}Tc-radiopharmaceutical dose distribution at the myocardium. Radiological data manipulation was performed in order to create a computational voxel model of the heart. A set of images obtained by thoracic angiotomography and abdominal aorta was set up providing anatomic and functional information for heart modeling in SISCODES code. A homogeneous distribution of {sup 99m}Tc was assumed into the cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissues were performed on the MCNP - Monte Carlo Code. The spatial dose distribution in the heart model is displayed as well as the dose versus volume histogram of the heart muscle. The present computational tools can generate spatial doses distribution in myocardial perfusion imaging. Specially, the dosimetry performed elucidates imparted dose distribution in the myocardial muscle per unit of injected {sup 99m} Tc activity, which can contribute to future deterministic effect investigations. (author)

  13. A relative quantitative assessment of myocardial perfusion by first-pass technique: animal study

    Science.gov (United States)

    Chen, Jun; Zhang, Zhang; Yu, Xuefang; Zhou, Kenneth J.

    2015-03-01

    The purpose of this study is to quantitatively assess the myocardial perfusion by first-pass technique in swine model. Numerous techniques based on the analysis of Computed Tomography (CT) Hounsfield Unit (HU) density have emerged. Although these methods proposed to be able to assess haemodynamically significant coronary artery stenosis, their limitations are noticed. There are still needs to develop some new techniques. Experiments were performed upon five (5) closed-chest swine. Balloon catheters were placed into the coronary artery to simulate different degrees of luminal stenosis. Myocardial Blood Flow (MBF) was measured using color microsphere technique. Fractional Flow Reserve (FFR) was measured using pressure wire. CT examinations were performed twice during First-pass phase under adenosine-stress condition. CT HU Density (HUDCT) and CT HU Density Ratio (HUDRCT) were calculated using the acquired CT images. Our study presents that HUDRCT shows a good (y=0.07245+0.09963x, r2=0.898) correlation with MBF and FFR. In receiver operating characteristic (ROC) curve analyses, HUDRCT provides excellent diagnostic performance for the detection of significant ischemia during adenosine-stress as defined by FFR indicated by the value of Area Under the Curve (AUC) of 0.927. HUDRCT has the potential to be developed as a useful indicator of quantitative assessment of myocardial perfusion.

  14. Quantitative myocardial perfusion magnetic resonance imaging: the impact of pulsatile flow on contrast agent bolus dispersion

    Energy Technology Data Exchange (ETDEWEB)

    Graafen, Dirk; Hamer, Julia; Weber, Stefan; Schreiber, Laura M, E-mail: graafen@uni-mainz.de [Section of Medical Physics, Department of Radiology, Johannes Gutenberg University Medical Center, Mainz (Germany)

    2011-08-21

    Myocardial blood flow (MBF) can be quantified using T{sub 1}-weighted first-pass magnetic resonance imaging (MRI) in combination with a tracer-kinetic model, like MMID4. This procedure requires the knowledge of an arterial input function which is usually estimated from the left ventricle (LV). Dispersion of the contrast agent bolus may occur between the LV and the tissue of interest. The aim of this study was to investigate the dispersion under conditions of physiological pulsatile blood flow, and to simulate its effect on MBF quantification. The dispersion was simulated in coronary arteries using a computational fluid dynamics (CFD) approach. Simulations were accomplished on straight vessels with stenosis of different degrees and shapes. The results show that dispersion is more pronounced under resting conditions than during hyperemia. Stenosis leads to a reduction of dispersion. In consequence, dispersion results in a systematic MBF underestimation between -0.4% and -9.3%. The relative MBF error depends not only on the dispersion but also on the actual MBF itself. Since MBF under rest is more underestimated than under stress, myocardial perfusion reserve is overestimated between 0.1% and 4.5%. Considering other sources of errors in myocardial perfusion MRI, systematic errors of MBF by bolus dispersion are relatively small.

  15. A comparison of resting images from two myocardial perfusion tracers

    Energy Technology Data Exchange (ETDEWEB)

    Anagnostopoulos, C. [Royal Brompton Hospital, London (United Kingdom); Laney, R. [Royal Brompton Hospital, London (United Kingdom); Pennell, D. [National Heart and Lung Inst., London (United Kingdom); Proukakis, H. [University of Athens Medical School (Greece); Underwood, R. [National Heart and Lung Inst., London (United Kingdom)

    1995-09-01

    We have compared stress-redistribution and delayed rest thallium-201 with rest technetium-99m methoxyisobutylisonitrile (MIBI) tomograms in order to compare the tracers for the assessment of myocardial viability and to validate a rapid protocol combining the two tracers. We studied 30 consecutive patients with known or suspected coronary artery disease [group 1: 16 with normal left ventricular function, mean left ventricular ejection fraction (LVEF) 55%, SD 6%; group 2: 14 with abnormal function, mean LVEF 28%, SD 8%]. {sup 201}Tl was injected during infusion of adenosine followed by acquisition of conventional stress and redistribution tomograms. On a separate day, {sup 201}Tl was injected at rest with imaging 4 h later. {sup 99m}Tc-MIBI was then given at rest and imaging was performed. Three images were compared: redistribution {sup 201}Tl, rest {sup 201}Tl, and rest {sup 99m}Tc-MIBI. Tracer activity was classified visually and quantitatively in nine segments and segments with>50% activity were defined as containing clinically significant viable myocardium. Mean global tracer uptake as a percentage of maximum was similar in group 1 (rest {sup 201}Tl 69%{+-}12%, redistribution {sup 201}Tl 69%{+-}15%, rest {sup 99m}Tc-MIBI 70%{+-}13%), but in group 2 mean tracer uptake was significantly greater in the rest {sup 201}Tl images (59%{+-}16%) than in redistribution {sup 201}Tl images (53%{+-}17%) or rest {sup 99m}Tc-MIBI images (53%{+-}19%). Overall agreement for regional uptake score was excellent ({kappa} from 0.79 to 0.84), although there were a significant number of segments with less uptake shown by redistribution {sup 201}Tl and by rest {sup 99m}Tc-MIBI than by rest {sup 201}Tl in group 2. The number of segments with significant viable myocardium in group 1 was very similar between the three images but in group 2 rest {sup 201}Tl identified significantly more segments as viable than the other images. (orig./MG) (orig.). With 1 fig., 7 tabs.

  16. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio [University Hospital ' ' S.Orsola' ' , Cardio-Thoracic-Vascular Department, Cardio-Thoracic Radiology Unit, Bologna (Italy)

    2016-02-15

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  17. Prevalence of myocardial ischaemia as assessed with myocardial perfusion scintigraphy in patients with diabetes mellitus type 2 and mild anginal symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Wiersma, Jacobijne J.; Trip, Mieke D.; Piek, Jan J.; Tijssen, Jan G.P. [Academic Medical Center, Department of Cardiology, Amsterdam (Netherlands); Verberne, Hein J.; Eck-Smit, Berthe L.F. van [Academic Medical Center Amsterdam, Department of Nuclear Medicine, Amsterdam (Netherlands); Holt, Wik L. ten [Amstelland Hospital, Department of Cardiology, Amstelveen (Netherlands)

    2006-12-15

    To determine the prevalence and predictors of reversible myocardial perfusion defects, indicative of myocardial ischaemia, in patients with mild, stable anginal complaints [Canadian Cardiovascular Society classification (CCS) I-II/IV] and diabetes mellitus type 2 (T2DM). A total of 329 patients with T2DM and stable, mild anginal symptoms (CCS I-II/IV) underwent myocardial perfusion scintigraphy. Perfusion images were assessed using a five-point (semi)-quantitative scoring system according to a 17-segment myocardial model. One-hundred and fifty-six (47%) patients showed reversible myocardial perfusion defects defined as a summed difference score of {>=}3. Male gender [odds ratio (OR) 2.28, 95% CI 1.4-3.71, p=0.001], previous myocardial infarction (MI) without revascularisation (OR 3.04, 95% CI 1.28-7.24, p=0.01), and the use of two or more classes of anti-anginal medication (OR 2.36, 95% CI 1.48-3.76, p<0.001) were independent predictors for the presence of reversible defects. By contrast, lipid-lowering therapy reduced the possibility of reversible perfusion defects (OR 0.56, 95% CI 0.33-0.95, p=0.03). Approximately half of the patients with mild, stable angina pectoris and T2DM showed evidence of myocardial ischaemia. Male gender, previous MI and the use of anti-anginal medication were positive predictors and lipid-lowering therapy was a negative predictor for the results of the scintigraphic stress test. (orig.)

  18. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Yinghua [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Chen, Guang-Hong [Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Hacker, Timothy A.; Raval, Amish N. [Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Van Lysel, Michael S.; Speidel, Michael A., E-mail: speidel@wisc.edu [Department of Medical Physics and Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2014-07-15

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan was performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and 937

  19. Evaluation of the effect of myocardial perfusion after percutaneous coronary intervention in coronary artery disease by using intracoronary myocardial contrast echocardiography and two other angiographic techniques

    Institute of Scientific and Technical Information of China (English)

    WANG Hong; LIU Zheng; YANG Li; HUANG Lan; JIN Jun; SONG Yaoming; GENG Zhaohua; YU Xuejun; QIN Jun; ZHAO Gang; GAO Yunhua

    2007-01-01

    Detection of abnormal myocardial perfusion is crucial to the prognosis of patients with coronary artery disease (CAD) after they have undergone percutaneous coronary intervention (PCI).The objective of this study is to evaluate the effect of myocardial perfusion by three different methods-intra-coronary myocardial contrast echocardiography (ICMCE),corrected thrombolysis in myocardial infarction frame count (CTFC),and coronary blood flow velocity (BFV)-and to determine the value of these different methods in the evaluation of the effect of myocardial perfusion post-PCI.For the study sixty-eight patients were divided into four groups based on selective coronary angiography results:group A (normal coronary artery),group B (75%-95% coronary artery stenosis),group C (coronary artery stenosis > 95%) and group D (acute total coronary occlusion).The effect of myocardial reperfusion was evaluated using the above mentioned three methods 15 min after PCI.IC-MCE was also performed before PCI in group D.The quantitative parameters of MCE involved:contrast peak intensity,time to peak intensity and area under the curve,representing myocardial blood volume,reperfusion velocity and myocardial blood flow,respectively.No difference was found in CTFC between the coronary artery stenosis group and the normal group.BFV was slower in group D than in group A (P < 0.05).The myocardial blood volume and the myocardial blood flow of the IC-MCE quantitative parameters were markedly lower in group C compared with those in group A (P < 0.05),and there were significant differences in the three MCE parameters between group D and group A (P < 0.05).For those patients with acute or total occlusion,the levels of myocardial perfusion before and after PCI were similar,as determined by IC-MCE and visually analyzed from 61 segments (P < 0.05).Quantitative IC-MCE evaluation of myocardial reperfusion is more accurate than with the other two methods.Moreover,with qualitative IC-MCE the level of

  20. High-resolution myocardial perfusion mapping in small animals in vivo by spin-labeling gradient-echo imaging.

    Science.gov (United States)

    Kober, Frank; Iltis, Isabelle; Izquierdo, Marguerite; Desrois, Martine; Ibarrola, Danielle; Cozzone, Patrick J; Bernard, Monique

    2004-01-01

    An ECG and respiration-gated spin-labeling gradient-echo imaging technique is proposed for the quantitative and completely noninvasive measurement and mapping of myocardial perfusion in small animals in vivo. In contrast to snapshot FLASH imaging, the spatial resolution of the perfusion maps is not limited by the heart rate. A significant improvement in image quality is achieved by synchronizing the inversion pulse to the respiration movements of the animals, thereby allowing for spontaneous respiration. High-resolution myocardial perfusion maps (in-plane resolution=234 x 468 microm2) demonstrating the quality of the perfusion measurement were obtained at 4.7 T in a group of seven freely breathing Wistar-Kyoto rats under isoflurane anesthesia. The mean perfusion value (group average +/- SD) was 5.5 +/- 0.7 ml g(-1)min(-1). In four animals, myocardial perfusion was mapped and measured under cardiac dobutamine stress. Perfusion increased to 11.1 +/- 1.9 ml g(-1)min(-1). The proposed method is particularly useful for the study of small rodents at high fields.

  1. Comparison of Myocardial Perfusion Estimates From Dynamic Contrast-Enhanced Magnetic Resonance Imaging With Four Quantitative Analysis Methods

    Science.gov (United States)

    Pack, Nathan A.; DiBella, Edward V. R.

    2012-01-01

    Dynamic contrast-enhanced MRI has been used to quantify myocardial perfusion in recent years. Published results have varied widely, possibly depending on the method used to analyze the dynamic perfusion data. Here, four quantitative analysis methods (two-compartment modeling, Fermi function modeling, model-independent analysis, and Patlak plot analysis) were implemented and compared for quantifying myocardial perfusion. Dynamic contrast-enhanced MRI data were acquired in 20 human subjects at rest with low-dose (0.019 ± 0.005 mmol/kg) bolus injections of gadolinium. Fourteen of these subjects were also imaged at adenosine stress (0.021 ± 0.005 mmol/kg). Aggregate rest perfusion estimates were not significantly different between all four analysis methods. At stress, perfusion estimates were not significantly different between two-compartment modeling, model-independent analysis, and Patlak plot analysis. Stress estimates from the Fermi model were significantly higher (~20%) than the other three methods. Myocardial perfusion reserve values were not significantly different between all four methods. Model-independent analysis resulted in the lowest model curve-fit errors. When more than just the first pass of data was analyzed, perfusion estimates from two-compartment modeling and model-independent analysis did not change significantly, unlike results from Fermi function modeling. PMID:20577976

  2. Low-dose 4D myocardial perfusion with x-ray micro-CT

    Science.gov (United States)

    Clark, D. P.; Badea, C. T.

    2017-03-01

    X-ray CT is widely used, both clinically and pre-clinically, for fast, high-resolution, anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, temporally-resolved CT data can detail cardiac motion and blood flow dynamics for one-stop cardiovascular CT imaging procedures. In previous work, we demonstrated efficient, low-dose projection acquisition and reconstruction strategies for cardiac micro-CT imaging and for multiple-injection micro-CT perfusion imaging. Here, we extend this previous work with regularization based on rank-sparse kernel regression and on filtration with the Karhunen-Loeve transform. Using a dual source, prospectively gated sampling strategy which produces an approximately uniform distribution of projections, we apply this revised algorithm to the assessment of both myocardial perfusion and cardiac functional metrics from the same set of projection data. We test the algorithm in simulations using a modified version of the MOBY mouse phantom which contains realistic perfusion and cardiac dynamics. The proposed algorithm reduces the reconstruction error by 81% relative to unregularized, algebraic reconstruction. The results confirm our ability to simultaneously solve for cardiac temporal motion and perfusion dynamics. In future work, we will apply the algorithm and sampling protocol to small animal cardiac studies.

  3. Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition.

    Science.gov (United States)

    Shin, Taehoon; Nayak, Krishna S; Santos, Juan M; Nishimura, Dwight G; Hu, Bob S; McConnell, Michael V

    2013-03-01

    Three-dimensional cardiac magnetic resonance perfusion imaging is promising for the precise sizing of defects and for providing high perfusion contrast, but remains an experimental approach primarily due to the need for large-dimensional encoding, which, for traditional 3DFT imaging, requires either impractical acceleration factors or sacrifices in spatial resolution. We demonstrated the feasibility of rapid three-dimensional cardiac magnetic resonance perfusion imaging using a stack-of-spirals acquisition accelerated by non-Cartesian k-t SENSE, which enables entire myocardial coverage with an in-plane resolution of 2.4 mm. The optimal undersampling pattern was used to achieve the largest separation between true and aliased signals, which is a prerequisite for k-t SENSE reconstruction. Flip angle and saturation recovery time were chosen to ensure negligible magnetization variation during the transient data acquisition. We compared the proposed three-dimensional perfusion method with the standard 2DFT approach by consecutively acquiring both data during each R-R interval in cardiac patients. The mean and standard deviation of the correlation coefficients between time intensity curves of three-dimensional versus 2DFT were 0.94 and 0.06 across seven subjects. The linear correlation between the two sets of upslope values was significant (r = 0.78, P < 0.05).

  4. Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection

    Science.gov (United States)

    Tang, Jing; Rahmim, Arman; Lautamäki, Riikka; Lodge, Martin A.; Bengel, Frank M.; Tsui, Benjamin M. W.

    2009-05-01

    The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32× 32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm-1 Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <~3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.

  5. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  6. Changes in myocardial perfusion after catheter-based percutaneous laser revascularisation

    Energy Technology Data Exchange (ETDEWEB)

    Kluge, R.; Barthel, H. [Leipzig Univ. (Germany). Dept. of Nuclear Medicine; Lauer, B.; Stahl, F.; Schuler, G. [Dept. of Cardiology, Heart Center, Univ. of Leipzig (Germany)

    2000-09-01

    This study investigated the effect of percutaneous laser revascularisation (PMR) on regional myocardial blood flow. PMR is a new therapeutic modality for patients suffering from angina pectoris due to coronary artery disease (CAD) that is not amenable to revascularisation. Initial clinical studies discovered reduced angina pectoris and increased exercise capacity after PMR. There are no previous clinical studies reporting the impact of PMR on perfusion. Thirty-six patients with end-stage CAD underwent thallium-201 single-photon emission tomography studies on four different occasions: immediately before PMR and 3, 6 and 12 months following PMR. Each study consisted of pharmacological stress and rest scintigraphy. Semiquantitative evaluation was performed by use of 14 standardised wall segments which were classified (a) according to the localisation of the PMR target region into treated segments, segments adjacent to the treated area and non-treated segments and (b) according to the pre-therapeutic local perfusion into four groups: no (0), slight (I), moderate (II) or severe (III) perfusion deficit. At stress in treated segments of groups II and III local scintigraphic count densities increased from 60.1% and 34.7% at baseline to 65.3% and 48.3% after 12 months (P<0.05) while they decreased in segments of group 0 from 94.2% to 85.7% (P<0.05). In rest studies no changes occurred. Thus, the local rest-stress differences within the target areas become smaller after PMR. In the PMR target area but not in the non-treated area an improvement in regional myocardial flow reserve occurs in wall segments with initially severely or moderately reduced stress perfusion. This effect is consistent with the clinical improvement after PMR. (orig.)

  7. Prevalence and predictors of an abnormal stress myocardial perfusion study in asymptomatic patients with type 2 diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Scholte, Arthur J.H.A.; Schuijf, Joanne D.; Wall, Ernst E. van der; Bax, Jeroen J. [Leiden University Medical Center, Department of Cardiology, Albinusdreef 2, PO Box 9600, Leiden (Netherlands); Kharagjitsingh, Antje V. [Medisch Centrum Haaglanden, Department of Internal Medicine, The Hague (Netherlands); Dibbets-Schneider, Petra; Stokkel, Marcel P. [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands)

    2009-04-15

    The purpose of this study was to evaluate the prevalence of an abnormal stress myocardial perfusion study in a cohort of truly asymptomatic patients with type 2 diabetes mellitus using myocardial perfusion imaging by means of single photon emission computed tomography (SPECT). Secondly, we determined which clinical characteristics may predict an abnormal stress myocardial perfusion study in this population. A total of 120 asymptomatic patients (mean age 53{+-}10 years) with type 2 diabetes mellitus and one or more risk factors for coronary artery disease were prospectively recruited from an outpatient diabetes clinic. All patients underwent myocardial perfusion imaging by means of adenosine {sup 99m}Tc sestamibi SPECT. Images were evaluated for the presence of perfusion abnormalities as well as other nonperfusion abnormalities that may indicate extensive ischaemia, including left ventricular dysfunction (defined as a left ventricular ejection fraction <45%), transient ischaemic dilatation and adenosine-induced ST segment depression. Multivariable analysis was performed using a backward selection strategy to identify potential predictors for an abnormal stress myocardial perfusion study. Finally, all patients were followed up for 12 months to determine the occurrence of cardiovascular events: (1) cardiac death, (2) nonfatal myocardial infarction, (3) unstable angina requiring hospitalization, (4) revascularization, or (5) stroke. Of the 120 patients, 40 (33%) had an abnormal stress study, including myocardial perfusion abnormalities in 30 patients (25%). In 10 patients (8%), indicators of extensive (possibly balanced ischaemia) were observed in the absence of abnormal perfusion. The multivariable analysis identified current smoking, duration of diabetes and the cholesterol/high-density lipoprotein (HDL) ratio as independent predictors of an abnormal stress study. During a follow-up period of 12 months six patients (5%) had a cardiovascular event. The current study

  8. Myocardial perfusion imaging in Denmark: activity from 1997 to 2001 and current practice

    DEFF Research Database (Denmark)

    Petersen, Claus Leth; Kjaer, Andreas

    2003-01-01

    A questionnaire was sent to all departments of nuclear medicine in Denmark (n=20) asking for details of myocardial perfusion imaging (MPI), including the number of patients examined each year from 1997 to 2001 and the current clinical and technical practice. All (100%) departments replied...... studies was dipyridamole/adenosine in 76%, exercise in 18% and dobutamine in 6%. Despite these encouraging figures, MPI activity for 2001 remained well below what is recommended by other national and international societies. The anticipated further increase in nuclear cardiology is encouraging...

  9. Regadenoson in Myocardial Perfusion Study - First Institutional Experiences in Bosnia and Herzegovina

    Science.gov (United States)

    Beslic, Nermina; Milardovic, Renata; Sadija, Amera; Ceric, Sejla; Raic, Zeljka

    2016-01-01

    Introduction: Myocardial perfusion imaging (MPI) is widely used in the evaluation of known and suspected coronary artery disease (CAD). Imaging of heart in stress and rest enables the comparison of myocardial uptake of radiotracer in proportion to the needs and coronary flow, which is used for detection of perfusion defects. Exercise stress and pharmacologic agents are used for the stressing purpose. Novel pharmacologic stressor regadenoson is A2A selective adenosine agonist, which selectively binds to the adenosine receptors in coronary arteries causing coronary dilatation. Materials and methods: We analyzed 50 myocardial perfusion studies performed with regadenoson as a pharmacologic agent that was injected before Tc99m-sestamibi in stress imaging. Stress and rest sets of images were evaluated for relative uptake of Tc99m-sestamibi in order to detect and characterize perfusion defects. After the injection of regadenoson, hemodynamic parameters and potential side-effects were closely monitored. Side-effects were stratified per severity as mild, moderate and severe. Studies were read by nuclear medicine physicians using quantitative perfusion SPECT software. Additional diagnostic information such as wall motion and wall thickening were provided by gating. Results: Thirty-three patients (66%) experienced one or more side-effects upon the administration of regadenoson, most commonly warmth and chest discomfort. In all patients but one (98%), the symptoms were mild, of short duration and self-limiting. Out of all side-effects registered, 44 (96%) were mild, and 2 (4%) were moderate. Two moderate side-effects developed in one patient with a prior history of asthma, and included shortness of breath and cough. Heart rate changed by 16 +- 31 bpm. Highest increase in blood pressure was 30 mm Hg for systolic, and 10 mm Hg for diastolic. One case of significant decrease in blood pressure was noted from the hypertensive basal values, 50 mm for systolic, and 30 mm Hg for

  10. Clinical experience with technetium-99m teboroxime, a neutral, lipophilic myocardial perfusion imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, L.L.; Seldin, D.W. (Columbia Univ., New York, NY (USA))

    1990-10-16

    Technetium-99m (Tc-99m) teboroxime is a new technetium-based myocardial perfusion imaging agent (investigational code = SQ30217 (Cardiotec, Squibb Diagnostics)). A member of a class of neutral, lipophilic, technetium-containing complexes known as boronic acid adducts of technetium dioxime (BATO) complexes, this agent is chemically very different from the cationic tracer thallium-201 (Tl-201) and from the cationic technetium complex Tc-99m sestamibi (Cardiolite, Du Pont Imaging Agents). Tc-99m teboroxime has high myocardial extraction, rapid blood clearance, little lung uptake and rapid myocardial washout. A biexponential pattern of myocardial washout is demonstrated in animals and in man. Effective half-lives of the 2 washout components in man are 5.2 minutes and 3.8 hours and represent approximately 66 and 33% of the myocardial activity, respectively. The first half-life for the myocardium is approximately 11 minutes. As the agent washes out of the heart, hepatic uptake occurs, peaking at about 5 minutes after injection. The liver is the major organ of excretion and receives, along with the large bowel, the largest radiation dose. Rapid imaging protocols using standard cameras have achieved good myocardial counts from 3 planar views acquired over a 4- to 5-minute period or for single photon emission computed tomography (SPECT) images acquired over a 10-minute period. An entire stress/rest procedure can be completed in 1 hour. Analysis of data from 155 patients from 4 centers using planar or SPECT imaging showed a sensitivity and specificity for blinded readings of 82 and 91%, respectively, when compared against overall clinical impression. 13 references.

  11. Attenuated predictive power of a normal myocardial perfusion scan in young smokers.

    Science.gov (United States)

    Wolak, Arik; Rafaeli, Einat; Toledano, Ronen; Novack, Victor; Gilutz, Harel; Henkin, Yaakov

    2014-06-01

    The negative predictive value of a normal myocardial perfusion image (MPI) for myocardial infarction or cardiac death is very high. However, it is unclear whether a normal MPI, reflecting non-compromised blood flow in the stable state, would have the same prognostic implications in smokers as in patients who do not smoke. The incidence of total mortality, cardiovascular mortality, and myocardial infarction was evaluated in 11,812 subjects (14.6% of whom were current smokers at the time of the study) with a normal MPI study and no past history of coronary artery disease during the period 1997 to 2008. During an average follow-up of 72.4 ± 32.4 months the risk for an acute myocardial infarction in current smokers was approximately 50% higher than the corresponding risk in non-smokers, despite a younger average age. Cox proportional regression models show that current smoking was associated with an increased hazard rate for the composite endpoint below age 60 (HR=2.09, 95%CI 1.43-3.07, pInternal Medicine. Published by Elsevier B.V. All rights reserved.

  12. Confluence of Depression and Acute Psychological Stress Among Patients With Stable Coronary Heart Disease: Effects on Myocardial Perfusion

    Science.gov (United States)

    Burg, Matthew M.; Meadows, Judith; Shimbo, Daichi; Davidson, Karina W.; Schwartz, Joseph E.; Soufer, Robert

    2014-01-01

    Background Depression is prevalent in coronary heart disease (CHD) patients and increases risk for acute coronary syndrome (ACS) recurrence and mortality despite optimal medical care. The pathways underlying this risk remain elusive. Psychological stress (PS) can provoke impairment in myocardial perfusion and trigger ACS. A confluence of acute PS with depression might reveal coronary vascular mechanisms of risk. We tested whether depression increased risk for impaired myocardial perfusion during acute PS among patients with stable CHD. Methods and Results Patients (N=146) completed the Beck Depression Inventory‐I (BDI‐I), a measure of depression linked to recurrent ACS and post‐ACS mortality, and underwent single‐photon emission computed tomography myocardial perfusion imaging at rest and during acute PS. The likelihood of new/worsening impairment in myocardial perfusion from baseline to PS as a function of depression severity was tested. On the BDI‐I, 41 patients scored in the normal range, 48 in the high normal range, and 57 in the depressed range previously linked to CHD prognosis. A BDI‐I score in the depressed range was associated with a significantly greater likelihood of new/worsening impairment in myocardial perfusion from baseline to PS (odds ratio =2.89, 95% CI: 1.26 to 6.63, P=0.012). This remained significant in models controlling ACS recurrence/mortality risk factors and medications. There was no effect for selective serotonin reuptake inhibitor medications. Conclusions Depressed patients with CHD are particularly susceptible to impairment in myocardial perfusion during PS. The confluence of PS with depression may contribute to a better understanding of the depression‐associated risk for ACS recurrence and mortality. PMID:25359402

  13. Pulmonary artery and right ventricle assessment in pulmonary hypertension. Correlation between functional parameters of ECG-gated CT and right-side heart catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Abel, Elodie; Jankowski, Adrien [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Pison, Christophe [Clinique univ. de pneumologie, CHU Grenoble (France); Bosson, Jean Luc [Dept. of Statistics, CIC, CHU Grenoble (France); Bouvaist, Helene [Clinique univ. de cardiologie, CHU Grenoble (France); Ferretti, Gilbert R. [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Univ. J. Fourier, Grenoble (France); INSERM U 823, Inst. A. Bonniot, la Tronche (France)], e-mail: gferretti@chu-grenoble.fr

    2012-09-15

    Background: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. Purpose: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. Material and Methods: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. Results: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P 0.005) correlated equally with RHC-CO. Conclusion: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for

  14. Investigation of optimal acquisition time of myocardial perfusion scintigraphy using cardiac focusing-collimator

    Science.gov (United States)

    Niwa, Arisa; Abe, Shinji; Fujita, Naotoshi; Kono, Hidetaka; Odagawa, Tetsuro; Fujita, Yusuke; Tsuchiya, Saki; Kato, Katsuhiko

    2015-03-01

    Recently myocardial perfusion SPECT imaging acquired using the cardiac focusing-collimator (CF) has been developed in the field of nuclear cardiology. Previously we have investigated the basic characteristics of CF using physical phantoms. This study was aimed at determining the acquisition time for CF that enables to acquire the SPECT images equivalent to those acquired by the conventional method in 201TlCl myocardial perfusion SPECT. In this study, Siemens Symbia T6 was used by setting the torso phantom equipped with the cardiac, pulmonary, and hepatic components. 201TlCl solution were filled in the left ventricular (LV) myocardium and liver. Each of CF, the low energy high resolution collimator (LEHR), and the low medium energy general purpose collimator (LMEGP) was set on the SPECT equipment. Data acquisitions were made by regarding the center of the phantom as the center of the heart in CF at various acquisition times. Acquired data were reconstructed, and the polar maps were created from the reconstructed images. Coefficient of variation (CV) was calculated as the mean counts determined on the polar maps with their standard deviations. When CF was used, CV was lower at longer acquisition times. CV calculated from the polar maps acquired using CF at 2.83 min of acquisition time was equivalent to CV calculated from those acquired using LEHR in a 180°acquisition range at 20 min of acquisition time.

  15. Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging-Technological Aspects and Clinical Applications.

    Science.gov (United States)

    Ben-Haim, Simona; Kennedy, John; Keidar, Zohar

    2016-07-01

    Myocardial perfusion imaging plays an important role in the assessment of patients with known or suspected coronary artery disease and is well established for diagnosis and for prognostic evaluation in these patients. The dedicated cardiac SPECT cameras with solid-state cadmium zinc telluride (CZT) detectors were first introduced a decade ago. A large body of evidence is building up, showing the superiority of the new technology compared with conventional gamma cameras. Not only the CZT detectors, but also new collimator geometries, the ability to perform focused imaging optimized for the heart and advances in data processing algorithms all contribute to the significantly improved sensitivity up to 8-10 times, as well as improved energy resolution and improved reconstructed spatial resolution compared with conventional technology. In this article, we provide an overview of the physical characteristics of the CZT cameras, as well as a review of the literature published so far, including validation studies in comparison with conventional myocardial perfusion imaging and with invasive coronary angiography, significant reduction in radiation dose, and new imaging protocols enabled by the new technology.

  16. Myocardial perfusion scintigraphy fi ndings in patients with mild coronary atherosclerotic lesions on coronary angiography

    Directory of Open Access Journals (Sweden)

    Zeki Dostbil

    2010-09-01

    Full Text Available Objectives: Myocardial perfusion scintigraphy (MPS iswidely used in functional assessment of myocardial per-fusion. But, some study results are in contradiction withseverity of coronary artery disease detected by coronaryangiography (CA. It is frequently encountered case thatCA is completely normal whereas MPS describes isch-emia. In this study, we aimed to investigate whether mildatherosclerotic lesions cause ischemia.Materials and methods: MPS with 99mTc-MIBI was per-formed in 52 patients who applied to cardiology clinics forhistory of chest pain and underwent diagnostic CA within3 months.Results: In 22 of 52 patients with mild atherosclerotic le-sions, ischemia in various degrees was detected on MPS.In statistical analysis, any signifi cant relationship was notfound between ischemia and gender, hypertension, DM,dyslipidemia, smoking, mitral valve insuffi ciency, left ven-tricular hypertrophy, exercise testing result and affectedcoronary artery.Conclusion: Our study fi ndings have shown that mild ath-erosclerotic lesions even at very early stage may causemyocardial ischemia

  17. Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

    Directory of Open Access Journals (Sweden)

    Olusegun Akinwale Ayeni

    2016-07-01

    Full Text Available Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, situs inversus may occur with or without dextrocardia. Situs inversus accompanied with dextrocardia (situs inversus totalis is a rare congenital abnormality occurring in 0.01% of live births. Herein, we present the case of a 35-yearold man with previously diagnosed situs inversus totalis with mirror-image dextrocardia, referred to our facility for diagnosis of coronary artery disease (CAD. The incidence and presentation of CAD in patients with dextrocardiaare similar to the normal population. However, considerable attention should be paid to the acquisition of myocardial perfusion scintigraphy and data processing/analysis in this group of patients. The present case highlights thedistinctive applications and potential pitfalls of myocardial perfusion single photon emission computed tomography (SPECT imaging in patients with dextrocardia.

  18. Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report.

    Science.gov (United States)

    Ayeni, Olusegun Akinwale; Malan, Nico; Hammond, Emmanuel Niiboye; Vangu, Mboyo-Di-Tamba Heben

    2016-01-01

    Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, situs inversus may occur with or without dextrocardia. Situs inversus accompanied with dextrocardia (situs inversus totalis) is a rare congenital abnormality occurring in 0.01% of live births. Herein, we present the case of a 35-year-old man with previously diagnosed situs inversus totalis with mirror-image dextrocardia, referred to our facility for diagnosis of coronary artery disease (CAD). The incidence and presentation of CAD in patients with dextrocardia are similar to the normal population. However, considerable attention should be paid to the acquisition of myocardial perfusion scintigraphy and data processing/analysis in this group of patients. The present case highlights the distinctive applications and potential pitfalls of myocardial perfusion single-photon emission computed tomography (SPECT) imaging in patients with dextrocardia.

  19. Robust dynamic myocardial perfusion CT deconvolution using adaptive-weighted tensor total variation regularization

    Science.gov (United States)

    Gong, Changfei; Zeng, Dong; Bian, Zhaoying; Huang, Jing; Zhang, Xinyu; Zhang, Hua; Lu, Lijun; Feng, Qianjin; Liang, Zhengrong; Ma, Jianhua

    2016-03-01

    Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for diagnosis and risk stratification of coronary artery disease by assessing the myocardial perfusion hemodynamic maps (MPHM). Meanwhile, the repeated scanning of the same region results in a relatively large radiation dose to patients potentially. In this work, we present a robust MPCT deconvolution algorithm with adaptive-weighted tensor total variation regularization to estimate residue function accurately under the low-dose context, which is termed `MPD-AwTTV'. More specifically, the AwTTV regularization takes into account the anisotropic edge property of the MPCT images compared with the conventional total variation (TV) regularization, which can mitigate the drawbacks of TV regularization. Subsequently, an effective iterative algorithm was adopted to minimize the associative objective function. Experimental results on a modified XCAT phantom demonstrated that the present MPD-AwTTV algorithm outperforms and is superior to other existing deconvolution algorithms in terms of noise-induced artifacts suppression, edge details preservation and accurate MPHM estimation.

  20. What is the benefit of CT-based attenuation correction in myocardial perfusion SPET?

    Science.gov (United States)

    Apostolopoulos, Dimitrios J; Savvopoulos, Christos

    2016-01-01

    In multimodality imaging, CT-derived transmission maps are used for attenuation correction (AC) of SPET or PET data. Regarding SPET myocardial perfusion imaging (MPI), however, the bene����t of CT-based AC (CT-AC) has been questioned. Although most attenuation-related artifacts are removed by this technique, new false defects may appear while some true perfusion abnormalities may be masked. The merits and the drawbacks of CT-AC in MPI SPET are reviewed and discussed in this editorial. In conclusion, CT-AC is most helpful in men, overweight in particular, and in those with low or low to intermediate pre-test probability of coronary artery disease (CAD). It is also useful for the evaluation of myocardial viability. In high-risk patients though, CT-AC may underestimate the presence or the extent of CAD. In any case, corrected and non-corrected images should be viewed side-by-side and both considered in the interpretation of the study.

  1. TU-G-204-03: Dynamic CT Myocardial Perfusion Measurement Using First Pass Analysis and Maximum Slope Models

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, L; Ziemer, B; Sadeghi, B; Javan, H; Lipinski, J; Molloi, S [University of California, Irvine, CA (United States)

    2015-06-15

    Purpose: To evaluate the accuracy of dynamic CT myocardial perfusion measurement using first pass analysis (FPA) and maximum slope models. Methods: A swine animal model was prepared by percutaneous advancement of an angioplasty balloon into the proximal left anterior descending (LAD) coronary artery to induce varying degrees of stenosis. Maximal hyperaemia was achieved in the LAD with an intracoronary adenosine drip (240 µg/min). Serial microsphere and contrast (370 mg/mL iodine, 30 mL, 5mL/s) injections were made over a range of induced stenoses, and dynamic imaging was performed using a 320-row CT scanner at 100 kVp and 200 mA. The FPA CT perfusion technique was used to make vessel-specific myocardial perfusion measurements. CT perfusion measurements using the FPA and maximum slope models were validated using colored microspheres as the reference gold standard. Results: Perfusion measurements using the FPA technique (P-FPA) showed good correlation with minimal offset when compared to perfusion measurements using microspheres (P- Micro) as the reference standard (P -FPA = 0.96 P-Micro + 0.05, R{sup 2} = 0.97, RMSE = 0.19 mL/min/g). In contrast, the maximum slope model technique (P-MS) was shown to underestimate perfusion when compared to microsphere perfusion measurements (P-MS = 0.42 P -Micro −0.48, R{sup 2} = 0.94, RMSE = 3.3 mL/min/g). Conclusion: The results indicate the potential for significant improvements in accuracy of dynamic CT myocardial perfusion measurement using the first pass analysis technique as compared with the standard maximum slope model.

  2. Effect of a distal protection device on epicardial blood flow and myocardial perfusion in primary percutaneous coronary intervention

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objective: The beneficial effect of percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) has been well established, but there is the problem of no-reflow phenomenon which is an adverse prognostic factor in primary PCI. In the present study the effect of a distal protection device (PercuSurge GuardWire; GW) on epicardial blood flow and myocardial perfusion was evaluated. Methods and Results: Patients with AMI were randomly divided into 2 groups, the GW and the control groups. The GW group included 52 patients with AMI who underwent primary PCI with GW protection and the control group included 60 patients who underwent primary PCI without GW protection. Epicardial blood flow in the infarct-related artery (IRA) and myocardial perfusion were evaluated according to the thrombolysis in myocardial infarction (TIMI) flow grade and the myocardial blush grade (MBG). We found TIMI score of 3 was obtained significantly more frequently in the GW group (96%) than in the control group (80%). The MBG score of 3 was obtained also significantly greater in the GW group (65%) than in the control group (33%). Conclusion: Primary PCI with GW protection can significantly improve epicardial blood flow and myocardial perfusion.

  3. Static Myocardial Perfusion Imaging using denoised dynamic Rb-82 PET/CT scans

    DEFF Research Database (Denmark)

    Petersen, Maiken N.M.; Hoff, Camilla; Harms, Hans

    Introduction: Relative and absolute measures of myocardial perfusion are derived from a single 82Rb PET/CT scan. However, images are inherently noising due to the short half-life of 82Rb. We have previously shown that denoising techniques can be applied to dynamic 82Rb series with excellent....... Administered 82Rb dose was 1110 MBq. Denoising using HYPR-LR or Hotelling 3D algorithms was performed as post-processing on the dynamic images series. Static series were created by summing frames from 2.5-5 min. The image data was analysed in QPET (Cedars-Sinai). Relative segmental perfusion (normalized...... and Bland-Altman analysis. Results: For HYPR-LR, a good correlation was found for relative segmental perfusion for both stress (y=1.007x+0.313, R2=0.98) and rest (y=1.007x+ 0.421, R2=0.96) scans with negative bias of -0.79±1.44 and -0.90±1.63, respectively. Correlations for SSS (R2=0.94), SRS (R2=0.92), SDS...

  4. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  5. Quantitative myocardial perfusion PET parametric imaging at the voxel-level.

    Science.gov (United States)

    Mohy-Ud-Din, Hassan; Lodge, Martin A; Rahmim, Arman

    2015-08-01

    Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the (82)Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves.

  6. Effect of Diltiazem on Coronary Artery Flow and Myocardial Perfusion in Patients With Isolated Coronary Artery Ectasia and Either Stable Angina Pectoris or Positive Myocardial Ischemic Stress Test.

    Science.gov (United States)

    Ozcan, Ozgur Ulas; Atmaca, Yusuf; Goksuluk, Huseyin; Akbulut, Irem Muge; Ozyuncu, Nil; Ersoy, Nedret; Erol, Cetin

    2015-10-15

    Isolated coronary artery ectasia (CAE) may be associated with stable or unstable coronary events despite the absence of epicardial coronary stenosis. Impaired coronary flow dynamics and myocardial perfusion have been demonstrated in stable patients with ectatic coronary arteries. We aimed to assess whether epicardial flow and tissue-level perfusion would be improved by diltiazem in myocardial regions subtended by the ectatic coronary arteries in patients with isolated CAE. A total of 60 patients with isolated CAE were identified of 9,780 patients who underwent elective coronary angiography. Patients were randomized to 5 mg of intracoronary diltiazem or saline. Coronary blood flow of the microvascular network was assessed using myocardial blush grade (MBG) technique. The thrombolysis in myocardial infarction (TIMI) flow grade and TIMI frame count (TFC) were used to assess epicardial coronary flow. MBG (from 2.4 to 2.6, p = 0.02), TIMI flow grades (from 2.4 to 2.8, p flow grade; and from 35 to 33, p = 0.43 for TFC). Diltiazem provided amelioration of the altered coronary flow dynamics, which was suggested as the pathophysiological influence of CAE. In conclusion, the favorable effects of the diltiazem on myocardial perfusion were observed at both epicardial and tissue levels.

  7. Exercise myocardial perfusion scintigraphy is useful for evaluating myocardial ischemia even in the elderly

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Uehara, Akihiko; Sugi, Toshihiko; Yamazaki, Keisuke [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Tawarahara, Kei; Mikami, Tadashi; Matoh, Fumitaka; Odagiri, Keiichi

    2000-06-01

    Pharmacologic stress testing is recommended to elderly patients as a valuable alternative to exercise testing. We examined whether exercise testing is as useful for evaluating myocardial ischemia in the elderly as in the young. The consecutive 1,508 patients who underwent exercise {sup 201}Tl single-photon emission computed tomography (SPECT) were divided into six age groups: 6-29 years (n=56), 30-44 (n=143), 45-54 (n=311), 55-64 (n=498), 65-74 (n=402), and 75-88 (n=98). Both heart rate and rate-pressure product at peak exercise were significantly lower in patients aged 75-88 than in the other five groups. The frequency of ischemic ST depression was higher in patients aged 75-88 than in those aged 6-74, although the difference was not significant. Moreover, the frequency of {sup 201}Tl transient defect was significantly higher in patients aged 75-88 than in those aged 6-74. On the other hand, the sensitivity of ischemic ST depression for {sup 201}Tl transient defect was similar among the six groups, but the specificity was significantly lower in patients aged 75-88 than in those aged 6-74. In conclusion, exercise {sup 201}Tl SPECT is useful for evaluating myocardial ischemia even in the elderly, but exercise electrocardiography has limitations such as lower specificity in the elderly than {sup 201}Tl SPECT. (author)

  8. The Myocardial Perfusion Scintigraphy in Predicting Risk for Coronary Artery Disease in Patients with Anxiety and Depression Symptoms

    Directory of Open Access Journals (Sweden)

    Billur Çalışkan

    2016-06-01

    Full Text Available INTRODUCTION: An association between psychological factors and cardiovascular disease, has long been suspected. However it is not clear whether chest pain is caused by emotional distress or whether coronary spasms are caused by the onset of coronary artery disease (CAD. We aimed to predict the risk for CAD in patients referred to myocardial perfusion imaging (MPI with chest pain using depression, stress, and anxiety symptoms. METHODS: The emotional status of all patients was evaluated using the Hospital Anxiety and Depression Scale (HADS-A and HADS-D, the State and Trait Anxiety Inventory (STAI-1 and STAI-2, the Perceived Stress Scale (PSS, and the Anxiety Sensitivity Index-3 (ASI. Myocardial perfusion was measured using a 17-segment model and 5-point scoring system (0: normal perfusion; 4: no perfusion. RESULTS: MPI revealed reversible perfusion defects in 24 of 141 patients and no perfusion defects in 117 patients. The STAI-2 and HADS-A and HADS-D scores were significantly higher in patients with myocardial ischemia than in those without (STAI-2: 50.8 ± 7.5 vs. 46.3 ± 7.1, respectively; p = 0.008; HADS-A: 9.5 ± 3.9 vs. 7.8 ± 3.4, respectively; p = 0.033; HADS-D: 8.7 ± 3.0 vs. 7.3 ± 3.0, respectively; p = 0.05. Unadjusted correlation analysis showed that there was statistically significant correlation between reversible perfusion defects and anxiety scores (r=0.186, p= 0.029. DISCUSSION AND CONCLUSION: The patients with symptoms of depression and high-trait anxiety may be at higher risk of myocardial ischemia than patients without such symptoms. Thus, the emotional status of patients should be taken into consideration during clinical evaluation for CAD.

  9. CT imaging of myocardial perfusion and viability. Beyond structure and function

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, U. Joseph [Medical University of South Carolina, Charleston, SC (United States). Dept. of Radiology and Radiological Sciences; Bamberg, Fabian [Muenchen Univ. (Germany); Bastarrika, Gorka [Sunnybrook Health Sciences Centre, Toronto, ON (Canada). Cardiothoracic Imaging Division; Ruzsics, Balazs [Royal Liverpool and Broadgreen Univ., Liverpool (United Kingdom). Dept. of Cardiology; Vliegenthart, Rozemarijn (ed.) [University Medical Center Groningen (Netherlands). Center for Medical Imaging

    2014-06-01

    First publication to be devoted to the subject. Reviews an advanced, promising application in healthcare. Spans multiple medical disciplines. The rapid evolution in cardiac computed tomography during the past decade has improved spatial and temporal resolution to the extent that cardiac CT is now an accepted alternative for the non-invasive interrogation of the heart. Beyond the assessment of cardiac structure and ventricular function, recent research has identified yet another promising CT application for the comprehensive diagnosis of coronary heart disease, namely the assessment of myocardial perfusion and viability. In this book, the first to be devoted to this novel application of CT, leading experts from across the world present up-to-date information and consider future directions. After short sections outlining the state of the art in the traditional applications of CT to image structure and function, the full range of CT techniques that may be employed to evaluate the myocardial blood supply are discussed in detail. Similarly, diverse CT approaches for the assessment of myocardial viability are described, with careful consideration of the available experimental and clinical evidence and the role of quantitative imaging.

  10. Myocardial perfusion/metabolism mismatch and ventricular arrhythmias in the chronic post infarction state

    Energy Technology Data Exchange (ETDEWEB)

    Krause, B.J.; Poeppel, T.D.; Vosberg, H.; Mueller, H.W. [Dept. of Nuclear Medicine, Heinrich Heine Univ., Duesseldorf (Germany); Reinhardt, M. [Praxis fuer Radiologie und Nuklearmedizin, Dorsten (Germany); Vester, E.G. [Dept. of Cardiology, Evangelisches Krankenhaus, Duesseldorf (Germany); Yong, M.; Mau, J. [Dept. of Statistics in Medicine, Heinrich Heine Univ., Duesseldorf (Germany); Strauer, B.E. [Dept. of Medicine, Div. of Cardiology, Angiology and Pulmonary Disease, Heinrich Heine Univ., Duesseldorf (Germany)

    2005-07-01

    Aim: Ventricular arrhythmias have been shown to originate in the myocardial peri-infarct region due to irregular heterotopic conduction. Hypoperfused but viable myocardium is often localised in those areas and may be involved in the pathogenesis of arrhythmias. We tested the hypothesis that these myocardial perfusion/metabolism mismatches (MM) are significantly associated with ventricular arrhythmias in the chronic post infarction state. Patients, methods: 47 post infarction patients were included in the study. 33 suffered from ventricular arrhythmia whereas 14 did not. All patients underwent {sup 99m}Tc tetrofosmin SPECT and {sup 18}F-FDG PET. A region-of-interest(ROI)-analysis was used to assess viable myocardium based on predefined MM-criteria. Univariate analyses as well as a logistic regression model for the multivariate analysis were carried out. Results: 94% of the arrhythmic patients displayed at least one MM-segment as compared to 64% of the non-arrhythmic patients. MM-segments and arrhythmia showed a statistically significant relation (p=0.018). The logistic regression model predicted the occurrence or absence of arrhythmia in 85% of all cases. Multivariate analysis gave consistent results, after adjusting for symptomatic chronic heart failure (CHF), aneurysms and age. Conclusion: Our results support the hypothesis that hypoperfused but viable myocardium represents an arrhyhmogenic substrate and is a relevant risk factor for developing ventricular arrhythmias following myocardial infarction. Therefore, the detection of MM-segments allows the identification of patients with a higher risk for future cardiac events. (orig.)

  11. Myocardial perfusion scintigraphy 2007 in Germany. Results of the query and current status

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, O. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Burchert, W. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Arbeitsgemeinschaft Kardiovaskulaere Nuklearmedizin der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Bengel, F.M. [Cardiovascular Nuclear Medicine, Johns Hopkins Medical Institutions, Baltimore (United States); Arbeitsgruppe Nuklearkardiologische Diagnostik der Deutschen Gesellschaft fuer Kardiologie (Germany); Zimmermann, R. [Arbeitsgruppe Nuklearkardiologische Diagnostik der Deutschen Gesellschaft fuer Kardiologie (Germany); Medizinische Klinik, Klinikum Pforzheim GmbH, Pforzheim (Germany); Dahl, J. vom [Klinik fuer Kardiologie, Kliniken Maria Hilf GmbH, Moenchengladbach (Germany); Schaefer, W. [Klinik fuer Nuklearmedizin, Universitaetsklinikum Aachen (Germany); Schober, O. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster UKM (Germany); Schaefers, M. [Arbeitsgemeinschaft Kardiovaskulaere Nuklearmedizin der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster UKM (Germany)

    2009-07-01

    Aim: This third survey of the working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine in cooperation with the working group Nuclear Cardiology of the German Cardiac Society was to deliver information on the procedures and in particular on the development of myocardial perfusion scintigraphy (MPS) from 2005 to 2007. Method: 370 questionnaires (222 private practices (PP), 117 hospitals (HO), 31 university hospitals (UH)) were evaluated. Results: MPS of 114,374 patients were reported, 83% were investigated with {sup 99m}Tc-perfusion tracers. 76% [2006=74%] were performed in PP, 15% [2006=17%] in HO and 9% [2006=9%] in UH. Diabetics represented 21% of all MPS patients in 2007. Data of 215 institutions which participated all from 2005 to 2007 showed an increase in MPS of 2.3% (PP +6.8%, HO -4.5%, UH -18.2%). The type of stress was pharmacological in 27% [2006 = 27%]; 67% adenosine (of these 25% with exercise), 31% dipyridamole (of these 55% with exercise), and 2% dobutamine. Gated SPECT was performed in 47% [2006 = 42%] of all rest and in 44% [2006 = 39%] of all stress MPS. 61% [2006 = 83%] of all institutions did not apply perfusion scores. 20% [2006 = 24%] of the institutions reported changes in the use of MPS by competing methods. Conclusion: There is a small increase of MPS between 2005 and 2007 despite competing methods. Gated SPECT has experienced more acceptance, but is still underrepresented. As compared to the European average and general standards of MPS a considerable backlog accounts to pharmacological stress tests, gated SPECT and perfusion scores. (orig.)

  12. Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice.

    Science.gov (United States)

    Wu, Max C; Hasegawa, Bruce H; Dae, Michael W

    2002-12-01

    The increasing use of transgenic mice as models of human physiology and disease has motivated the development of dedicated in vivo imaging systems for anatomic and functional characterization of mice as an adjunct to or a replacement for established ex vivo techniques. We have developed a pinhole single photon emission computed tomography (SPECT) system for high resolution imaging of mice with cardiovascular imaging as the primary application. In this work, we characterize the system performance through phantom studies. The spatial resolution and sensitivity were measured from images of a line source and point source, respectively, and were reported for a range of object-to-pinhole distances and pinhole diameters. Tomographic images of a uniform cylindrical phantom, Defrise phantom, and grid phantom were used to characterize the image uniformity and spatial linearity. The uniform phantom image did not contain any ring or reconstruction artifacts, but blurring in the axial direction was evident in the Defrise phantom images. The grid phantom images demonstrated excellent spatial linearity. A novel phantom modeling perfusion of the left ventricle of a mouse was designed and built with perfusion defects of varying sizes to evaluate the system performance for myocardial perfusion imaging of mice. The defect volumes were measured from the pinhole SPECT images and correlated to the actual defect volumes calculated according to geometric formulas. Linear regression analysis produced a correlation coefficient of r = 0.995 (p defect size in mice using pinhole SPECT. We have performed phantom studies to characterize the spatial resolution, sensitivity, image uniformity, and spatial linearity of the pinhole SPECT system. Measurement of the perfusion defect size is a valuable phenotypic assessment and will be useful for hypothesis testing in murine models of cardiovascular disease.

  13. Quantitative perfusion parameters in a cohort of patients with no known ischemic heart disease and normal myocardial perfusion imaging studied by 82Rb-PET

    DEFF Research Database (Denmark)

    Hoff, Camilla; Balche, Abdallah; Majgaard, J

    Purpose 82Rb perfusion PET allows for visual as well as quantitative interpretation of myocardial function. Whereas visual interpretation relies on intra-individual redistribution of the tracer between rest and stress studies, quantitative interpretation of absolute flow values requires robust......-month period were screened for eligibility. One hundred and eighty patients with no prior history of ischemic heart disease, a normal MPI scan defined by visual interpretation and no coronary events for a follow-up period of 6 months were included as normal. Quantitative parameters were calculated using...... commercially available software (QPET, Cedars Sinai). Parameters included were regional and global rest and stress myocardial blood flow (MBF) values, ejection fraction (EF) and total perfusion deficit (TPD). Results Mean global MBF at stress was 2.92 mL/g/min (±SD 0.49), lower limit (LL) 1.94 m...

  14. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J. [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Xu, J., E-mail: xujianr@hotmail.co [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China)

    2010-10-15

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 {+-} 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  15. Assessment of Double Outlet Right Ventricle Associated with Multiple Malformations in Pediatric Patients Using Retrospective ECG-Gated Dual-Source Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Ke Shi

    Full Text Available To evaluate the feasibility and diagnostic accuracy of retrospective electrocardiographically (ECG-gated dual-source computed tomography (DSCT for the assessment of double outlet right ventricle (DORV and associated multiple malformations in pediatric patients.Forty-seven patients <10 years of age with DORV underwent retrospective ECG-gated DSCT. The location of the ventricular septal defect (VSD, alignment of the two great arteries, and associated malformations were assessed. The feasibility of retrospective ECG-gated DSCT in pediatric patients was assessed, the image quality of DSCT and the agreement of the diagnosis of associated malformations between DSCT and transthoracic echocardiography (TTE were evaluated, the diagnostic accuracies of DSCT and TTE were referred to surgical results, and the effective doses were calculated.Apart from DORV, 109 associated malformations were confirmed postoperatively. There was excellent agreement (κ = 0.90 for the diagnosis of associated malformations between DSCT and TTE. However, DSCT was superior to TTE in demonstrating paracardiac anomalies (sensitivity, coronary artery anomalies: 100% vs. 80.00%, anomalies of great vessels: 100% vs. 88.57%, separate thoracic and abdominal anomalies: 100% vs. 76.92%, respectively. Combined with TTE, DSCT can achieve excellent diagnostic performance in intracardiac anomalies (sensitivity, 91.30% vs. 100%. The mean image quality score was 3.70 ± 0.46 (κ = 0.76. The estimated mean effective dose was < 1 mSv (0.88 ± 0.34 mSv.Retrospective ECG-gated DSCT is a better diagnostic tool than TTE for pediatric patients with complex congenital heart disease such as DORV. Combined with TTE, it may reduce or even obviate the use of invasive cardiac catheterization, and thus expose the patients to a much lower radiation dose.

  16. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lauzier, Pascal Theriault; Tang Jie; Speidel, Michael A.; Chen Guanghong [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705-2275 (United States); Department of Medical Physics and Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin 53705-2275 (United States)

    2012-07-15

    Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution

  17. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  18. Electrical neuromodulation improves myocardial perfusion and ameliorates refractory angina pectoris in patients with syndrome X : fad or future?

    NARCIS (Netherlands)

    Jessurun, G; Hautvast, RWM; Tio, RA; DeJongste, M

    2003-01-01

    At present, there is no reliable antianginal drug therapy for patients with cardiac syndrome X. Therefore, the effect of electrical neuromodulation on refractory angina pectoris and myocardial perfusion in cardiac syndrome X was assessed. Eight patients (aged 55 +/- 7 years) with heterogeneous myoca

  19. Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Nielsen, Gitte; Fritz-Hansen, Thomas; Dirks, Christina G

    2004-01-01

    with acute transmural myocardial infarction were studied using a Turbo-fast low angle shot (FLASH) MRI sequence to monitor the first pass of an extravascular contrast agent (CA), gadolinium diethylene triamine pentaacetic acid (Gd-DTPA). Quantitation of perfusion, expressed as Ki (mL/100 g/minute), in five...

  20. Positron emission tomographic evaluation of regulation of myocardial perfusion in physiological (elite athletes) and pathological (systemic hypertension) left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Meyer, Christian; Wachtell, Kristian

    2005-01-01

    Myocardial perfusion (MP) may differ in physiologic and pathologic left ventricular hypertrophy (LVH). We compared MP in LVH in elite athletes and patients with hypertension with healthy, age-matched subjects. We included 12 rowers with LVH, 19 patients with hypertension with LVH, and 2 age-match...

  1. Sex- and age-related differences of myocardial perfusion at rest assessed with multidetector computed tomography

    DEFF Research Database (Denmark)

    Byrne, Christina; Kühl, J Tobias; Zacho, Mette;

    2013-01-01

    The clinical presentation of ischemic heart disease in women differs from men, which could reflect sex-related differences of normal physiology. Cardiac CT angiography provides a noninvasive method to assess both regional and transmural myocardial perfusion in addition to coronary atherosclerosis....

  2. Caffeine intake inverts the effect of adenosine on myocardial perfusion during stress as measured by T1 mapping

    NARCIS (Netherlands)

    Kuijpers, Dirkjan; Prakken, Niek H.; Vliegenthart, Rozemarijn; van Dijkman, Paul R. M.; van der Harst, Pim; Oudkerk, Matthijs

    2016-01-01

    Caffeine intake before adenosine stress myocardial perfusion imaging may cause false negative findings. We hypothesized that the antagonistic effect of caffeine can be measured by T1 relaxation times in rest and adenosine stress cardiac magnetic resonance imaging (CMR), as T1 mapping techniques are

  3. Prediction of clinical outcome by myocardial CT perfusion in patients with low-risk unstable angina pectoris

    DEFF Research Database (Denmark)

    Linde, Jesper J; Sørgaard, Mathias; Kühl, Jørgen T

    2017-01-01

    The prognostic implications of myocardial computed tomography perfusion (CTP) analyses are unknown. In this sub-study to the CATCH-trial we evaluate the ability of adenosine stress CTP findings to predict mid-term major adverse cardiac events (MACE). In 240 patients with acute-onset chest pain, y...

  4. [Perfusion myocardial scintigraphy - SPECT with TC-99m MIBI in detection coronary artery desease in diabetic patients].

    Science.gov (United States)

    Heljić, Bećir; Kucukalić-Selimović, Elma; Begić, Alden; Begić, Amela

    2007-01-01

    Diabetes mellitus is very frequent disease. The prevalence of coronary artery disease is higher in diabetic than in non-diabetic patients. Coronary artery disease (CAD) is the main cause of morbidity and mortalitiy in patients with Diabetes mellitus. The aim of this study was to evaluate usfulnes of myocardial perfusion scintigraphy in diabetic patients for detection of coronary artery disease. this study included 15 patients with verified diabetes mellitus. All patients were treated with oral hypoglicemic or insulin. Parameters observed for every patients were level of lipemia (cholesterol, triglycerides), family hystory of CAD, hystory of chest pain. All patients underwent sress/rest Tc-99m MIBI study. We have performed one day protocol. Exercise tolerance test were performing in all patients according to the Bruce protocol. 260MBq was injected intravenously at peak exercise. 740MBg was injected for the rest. Myocardial perfusion scintigraphy was clasified as: 1. normal, 2. reversible defect or 3. irreversible defect. reversible perfusion defect we have found in 8 patients. The same patients had elevated glicemia, high level of lipemia; 1 patient had fixed defect, without any previous known history for myocardial infarction. In 6 patients we could not see any significant defect during stress/rest scintigraphy. The frequency of abnormal myocardial perfusion scintigraphy suggest that this procedure can be very useful in the detection of high-risk diabetic patients.

  5. High coronary artery calcium score affects clinical outcome despite normal stress myocardial perfusion imaging and normal left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Madsen, Claus Juul; Andersen, Kim F; Zerahn, Bo

    2013-01-01

    Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS...

  6. The value of low-dose prospective ECG-gated dual-source CT angiography in the diagnosis of coarctation of the aorta in infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Nie, P. [Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong (China); Wang, X., E-mail: wxming369@yahoo.com.cn [Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong (China); Cheng, Z.; Duan, Y.; Ji, X. [Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-Cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Shandong University, Jinan, Shandong (China); Chen, J. [CT Research Collaboration, Siemens, Beijing (China); Zhang, H. [Department of Cardiovascular Surgery, Shandong Provincial Hospital, Jinan, Shandong (China)

    2012-08-15

    Aim: To investigate the value of prospective electrocardiogram (ECG)-gated dual-source computed tomography (DSCT) in the diagnosis of coarctation of the aorta (CoA). Materials and methods: Seventeen patients clinically suspected of having CoA underwent prospective ECG-gated DSCT angiography and transthoracic echocardiography (TTE). Surgery was performed in all patients. The diagnostic accuracy of DSCT angiography and TTE was compared with the surgical findings as the reference standard. Image quality was evaluated using a five-point scale. Effective radiation dose was calculated from the dose-length product (DLP). Results: CoA was diagnosed in 17 patients by DSCT angiography and in 16 patients by TTE. A total of 46 separate cardiovascular abnormalities were confirmed by surgical findings. The diagnostic accuracy of DSCT angiography and TTE was 96.32% and 97.06%, respectively. There was no significant difference in the diagnostic accuracy between DSCT angiography and TTE ({chi}{sup 2} = 0, p > 0.05). The mean score of image quality was 4.2 {+-} 0.8. The mean effective dose was 0.69 {+-} 0.09 mSv. Conclusion: Prospective ECG-gated DSCT with a low radiation dose is a valuable technique in the diagnosis of CoA in infants and children.

  7. Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, Damien; Remy-Jardin, Martine; Salem, Randa; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques [Hospital Calmette, University Center of Lille, Department of Thoracic Imaging, Lille Cedex (France); Delannoy-Deken, Valerie; Duhamel, Alain [University of Lille, Department of Medical Statistics, Lille Cedex (France)

    2007-04-15

    To evaluate image quality in the assessment of the coronary arteries during routine ECG-gated multidetector CT (MDCT) of the chest. One hundred and thirty three patients in sinus rhythm underwent an ECG-gated CT angiographic examination of the entire chest without {beta}-blockers with a 64-slice CT system. In 127 patients (95%), it was possible to assess the coronary arteries partially or totally; coronary artery imaging failed in six patients (5%), leading to a detailed description of the coronary arteries in 127 patients. Considering ten coronary artery segments per patient, 75% of coronary segments were assessable (948/1270 segments). When the distal segments were excluded from the analysis (i.e., seven coronary segments evaluated per patient), the percentage of assessable segments was 86% (768/889 proximal and mid coronary segments) and reached 93% (474/508) when assessing proximal segments exclusively. The mean number of assessable segments was significantly higher in patients with a heart rate {<=}80 bpm (n=95) than in patients with a heart rate >80 bpm (n=38) (p<0.002). Proximal and mid-coronary segments can be adequately assessed during a whole-chest ECG-gated CT angiographic examination without administration of {beta}-blockers in patients with a heart rate below 80 bpm. (orig.)

  8. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  9. Quantitative myocardial perfusion imaging in a porcine ischemia model using a prototype spectral detector CT system

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Dhanantwari, Amar; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    We optimized and evaluated dynamic myocardial CT perfusion (CTP) imaging on a prototype spectral detector CT (SDCT) scanner. Simultaneous acquisition of energy sensitive projections on the SDCT system enabled projection-based material decomposition, which typically performs better than image-based decomposition required by some other system designs. In addition to virtual monoenergetic, or keV images, the SDCT provided conventional (kVp) images, allowing us to compare and contrast results. Physical phantom measurements demonstrated linearity of keV images, a requirement for quantitative perfusion. Comparisons of kVp to keV images demonstrated very significant reductions in tell-tale beam hardening (BH) artifacts in both phantom and pig images. In phantom images, consideration of iodine contrast to noise ratio and small residual BH artifacts suggested optimum processing at 70 keV. The processing pipeline for dynamic CTP measurements included 4D image registration, spatio-temporal noise filtering, and model-independent singular value decomposition deconvolution, automatically regularized using the L-curve criterion. In normal pig CTP, 70 keV perfusion estimates were homogeneous throughout the myocardium. At 120 kVp, flow was reduced by more than 20% on the BH-hypo-enhanced myocardium, a range that might falsely indicate actionable ischemia, considering the 0.8 threshold for actionable FFR. With partial occlusion of the left anterior descending (LAD) artery (FFR  <  0.8), perfusion defects at 70 keV were correctly identified in the LAD territory. At 120 kVp, BH affected the size and flow in the ischemic area; e.g. with FFR ≈ 0.65, the anterior-to-lateral flow ratio was 0.29  ±  0.01, over-estimating stenosis severity as compared to 0.42  ±  0.01 (p  <  0.05) at 70 keV. On the non-ischemic inferior wall (not a LAD territory), the flow ratio was 0.50  ±  0.04 falsely indicating an actionable ischemic condition in a healthy

  10. Angiography-based prediction of outcome after coronary artery bypass surgery versus changes in myocardial perfusion scintigraphy

    DEFF Research Database (Denmark)

    Eckardt, Rozy; Kjeldsen, Bo Juel; Haghfelt, Torben;

    2011-01-01

    The present study compared the clinical prediction of the effect of coronary artery bypass grafting (CABG) on coronary blood flow and left ventricular ejection fraction (LVEF) with changes in gated myocardial perfusion scintigraphy. A prospective group of 92 patients underwent myocardial perfusion...... predicted and observed regional changes in coronary blood flow and perfusion defects were poor. LVEF increased (by over five ejection fraction units) in almost half of the patients, but with no correlation between the predicted and the observed changes. Based on clinical and angiographic findings...... scintigraphy before and 6 months after CABG, the results being kept secret from the surgeon. Based on clinical and angiographic findings, the surgeons filled in a questionnaire indicating the predicted changes in coronary blood flow in each of the three coronary artery territories and in the LVEF. Symptomatic...

  11. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  12. Prognostic Value Of Normal Myocardial Perfusion Imaging In Asymptomatic Diabetic Patients With Moderate And High Calcium Scores

    Directory of Open Access Journals (Sweden)

    Mitevska Irena Peovska

    2015-06-01

    Full Text Available The purpose of this study was to evaluate the intermediate prognostic value of normal myocardial perfusion imaging (MPI in asymptomatic diabetic patients with intermediate and high coronary artery calcium (CAC scores. Methods: A total of 115 asymptomatic diabetic patients with no known coronary artery disease (CAD underwent MPI after multi-slice computed tomography CAC assessment for the detection of suspected CAD. The study included 75 patients with normal MPI results. A 17-segment model for myocardial perfusion and function analysis was used. Patients were divided into three groups: I gr-20 patients with a diabetes duration between 1-5 years; II gr-24 patients with a diabetes duration 5-10 years; and III gr-31 patients with a diabetes duration >10 years. End points (cardiac death, non-fatal myocardial infarction, heart failure, new angina, revascularization were assessed at 6, 12 and 24 months.

  13. Assessment of cardiac function using myocardial perfusion imaging technique on SPECT with 99mTc sestamibi

    Science.gov (United States)

    Gani, M. R. A.; Nazir, F.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    Suspicion on coronary heart disease can be confirmed by observing the function of left ventricle cardiac muscle with Myocardial Perfusion Imaging techniques. The function perfusion itself is indicated by the uptake of radiopharmaceutical tracer. The 31 patients were studied undergoing the MPI examination on Gatot Soebroto Hospital using 99mTc-sestamibi radiopharmaceutical with stress and rest conditions. Stress was stimulated by physical exercise or pharmacological agent. After two hours, the patient did rest condition on the same day. The difference of uptake percentage between stress and rest conditions will be used to determine the malfunction of perfusion due to ischemic or infarct. Degradation of cardiac function was determined based on the image-based assessment of five segments of left ventricle cardiac. As a result, 8 (25.8%) patients had normal myocardial perfusion and 11 (35.5%) patients suspected for having partial ischemia. Total ischemia occurred to 8 (25.8%) patients with reversible and irreversible ischemia and the remaining 4 (12.9%) patients for partial infarct with characteristic the percentage of perfusion ≤50%. It is concluded that MPI technique of image-based assessment on uptake percentage difference between stress and rest conditions can be employed to predict abnormal perfusion as complementary information to diagnose the cardiac function.

  14. Pericardial fat and myocardial perfusion in asymptomatic adults from the Multi-Ethnic Study of Atherosclerosis.

    Directory of Open Access Journals (Sweden)

    Tina E Brinkley

    Full Text Available BACKGROUND: Pericardial fat has adverse effects on the surrounding vasculature. Previous studies suggest that pericardial fat may contribute to myocardial ischemia in symptomatic individuals. However, it is unknown if pericardial fat has similar effects in asymptomatic individuals. METHODS: We determined the association between pericardial fat and myocardial blood flow (MBF in 214 adults with no prior history of cardiovascular disease from the Minnesota field center of the Multi-Ethnic Study of Atherosclerosis (43% female, 56% Caucasian, 44% Hispanic. Pericardial fat volume was measured by computed tomography. MBF was measured by MRI at rest and during adenosine-induced hyperemia. Myocardial perfusion reserve (PR was calculated as the ratio of hyperemic to resting MBF. RESULTS: Gender-stratified analyses revealed significant differences between men and women including less pericardial fat (71.9±31.3 vs. 105.2±57.5 cm(3, p<0.0001 and higher resting MBF (1.12±0.23 vs. 0.93±0.19 ml/min/g, p<0.0001, hyperemic MBF (3.49±0.76 vs. 2.65±0.72 ml/min/g, p<0.0001, and PR (3.19±0.78 vs. 2.93±0.89, p = 0.03 in women. Correlations between pericardial fat and clinical and hemodynamic variables were stronger in women. In women only (p = 0.01 for gender interaction higher pericardial fat was associated with higher resting MBF (p = 0.008. However, this association was attenuated after accounting for body mass index or rate-pressure product. There were no significant associations between pericardial fat and hyperemic MBF or PR after multivariate adjustment in either gender. In logistic regression analyses there was also no association between impaired coronary vasoreactivity, defined as having a PR <2.5, and pericardial fat in men (OR, 1.18; 95% CI, 0.82-1.70 or women (OR, 1.11; 95% CI, 0.68-1.82. CONCLUSIONS: Our data fail to support an independent association between pericardial fat and myocardial perfusion in adults without symptomatic

  15. Normal stress databases in myocardial perfusion scintigraphy – how many subjects do you need?

    DEFF Research Database (Denmark)

    Trägårdh, Elin; Sjöstrand, Karl; Edenbrandt, Lars

    2012-01-01

    Commercial normal stress databases in myocardial perfusion scintigraphy (MPS) commonly consist of 30–40 individuals. The aim of the study was to determine how many subjects are needed. Four normal stress databases were developed using patients who underwent 99mTc MPS: non‐corrected images (NC...... convergence. Coefficients of variation (CV) were created for increasing number of included patients in the four different normal stress databases. Normal stress databases with ... two and 35 subjects and 83% between two and 100 included subjects for NC man. We conclude that the commonly used 30–40 individuals for making a normal stress database might not be enough due to the high CV. We propose that normal stress databases should consist of more than 30–40 individuals...

  16. A Comparison of FFD-based Nonrigid Registration and AAMs Applied to Myocardial Perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Stegmann, Mikkel Bille; Ersbøll, Bjarne Kjær;

    2006-01-01

    Little work has been done on comparing the performance of statistical model-based approaches and nonrigid registration algorithms. This paper deals with the qualitative and quantitative comparison of active appearance models (AAMs) and a nonrigid registration algorithm based on free......-form deformations (FFDs). AAMs are known to be much faster than nonrigid registration algorithms. On the other hand nonrigid registration algorithms are independent of a training set as required to build an AAM. To obtain a further comparison of the two methods, they are both applied to automatically register multi......-slice myocardial perfusion images. The images are acquired by magnetic resonance imaging, from infarct patients. A registration of these sequences is crucial for clinical practice, which currently is subjected to manual labor. In the paper, the pros and cons of the two registration approaches are discussed...

  17. Usefulness of thallium-201 myocardial perfusion scintigraphy in the diagnosis of chronic cor pulmonale

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, S.; Tanaka, N.; Sawada, M.; Sakaguchi, K.; Fujita, K. (Osaka Prefectural Habikino Hospital, Osaka (Japan))

    1981-09-01

    To open up the possibility of exact clinical diagnoses of chronic cor pulmonale, we performed thallium-201 myocardial perfusion scintigraphy on patients with chronic pulmonary disease. From the thallium activity in the left ventricle (plus ventricular septum) and right ventricle counted scintigraphically, we determined the thallium activity ratio of left to right ventricle (TAR). The intra- and inter-observer variations of this ratio were negligible. We compared TAR with pulmonary hemodynamic findings and with left to right ventricular mass ratio measured at autopsy, and obtained the following results. 1) Left to right ventricular mass ratio determined in 11 autopsied patients by the method of Fulton et al. was closely correlated with TAR values (r = 0.90, p < 0.001). 2) In patients with chronic pulmonary disease, there were highly significant exponential inverse correlations between TAR and pulmonary arterial mean pressure, total pulmonary vascular resistance and right ventricular systolic pressure with the coefficients of -0.75, -0.72 or -0.77, respectively (p < 0.001). These results suggested the possibility that the severity of pulmonary circulatory disturbance may be ascertained non-invasively by TAR measurement. Thus, thallium-201 myocardial perfusion scintigraphy is able to reveal non-invasively right ventricular hypertrophy in patients with chronic pulmonary disease, and it might be a useful means of clinically diagnosing chronic cor pulmonale. If TAR obtained from scintigrams is smaller than 2, the patient concerned may possibly have right ventricular hypertrophy and he or she may be diagnosed as having chronic cor pulmonale.

  18. In vivo nuclear magnetic resonance imaging of myocardial perfusion using the paramagnetic contrast agent manganese gluconate.

    Science.gov (United States)

    Schaefer, S; Lange, R A; Kulkarni, P V; Katz, J; Parkey, R W; Willerson, J T; Peshock, R M

    1989-08-01

    Previous nuclear magnetic resonance (NMR) imaging studies have indicated that coronary occlusion does not produce sufficient changes in standard tissue relaxation times to allow the detection of acute ischemia. To identify acute myocardial perfusion abnormalities, the use of the paramagnetic agent manganese gluconate combined with calcium gluconate (MnGlu/CaGlu) was investigated in canine models of acute coronary artery occlusion. In vitro studies showed that MnGlu/CaGlu was a more efficient relaxing agent than gadolinium-DTPA (relaxivity of 7.8 versus 5.1 s-1 mM-1) and demonstrated affinity for normal myocardium. The distribution of MnGlu/CaGlu as measured by manganese-54 tracer studies was proportional to myocardial blood flow in both normal and ischemic tissue. Hearts excised from dogs after coronary artery occlusion and administration of 0.035 mM/kg MnGlu/CaGlu were imaged ex vivo using a relatively spin-lattice relaxation time (T1)-weighted gradient reversal technique (repetition time [TR] 50 ms and echo time [TE] 9 ms). These images showed increased signal intensity in the normally perfused myocardium with a mean signal intensity ratio of hypoperfused to normal myocardium of 0.55 +/- 0.12 (mean +/- SD). In vivo images obtained in nine dogs after coronary artery occlusion and administration of the same dose of MnGlu/CaGlu demonstrated the region of hypoperfused myocardium in six dogs with a signal intensity ratio of hypoperfused to normal myocardium of 0.64 +/- 0.23 (p less than 0.05 versus control). When a higher dose of 0.1 mM/kg MnGlu/CaGlu was utilized and in vivo imaging was performed using a relatively spin-spin relaxation time (T2)-weighted (TR gated, TE 60 ms) spin-echo sequence in six dogs, the signal intensity of normal myocardium was decreased.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. The routine use of sublingual GTN with resting 99Tcm-tetrofosmin myocardial perfusion imaging.

    Science.gov (United States)

    Thorley, P J; Sheard, K L; Wright, D J; Sivananthan, U M

    1998-10-01

    Nitrates can be used to improve resting myocardial blood flow in patients with severe coronary artery disease. This may enhance tracer uptake during rest myocardial perfusion imaging. Recent studies using nitrates at rest have shown increased detection of reversible ischaemia in this patient group with the 201Tl and 99Tcm perfusion tracers MIBI and tetrofosmin. However, it is not always possible to assess the severity of coronary artery disease before the rest injection and therefore whether a patient would benefit from nitrate administration. To improve the sensitivity for the detection of reversible ischaemia and to avoid a repeat study with nitrates (especially in patients with 'fixed' defects), a protocol in which all patients routinely receive nitrates prior to the rest injection is required. This prospective study evaluated the effect of nitrate administration prior to rest imaging in a randomly selected group of patients. Thirty patients selected at random from routine referrals had stress, rest and rest + GTN tetrofosmin imaging on three separate days. Changes in reversibility between the rest and rest + GTN images were assessed both visually and using semi-quantitative analysis. Defects at stress were seen in 43 coronary artery territories, 33 of which were reversible at rest and 37 reversible at rest + GTN. Of these 43 defects, 82% demonstrated either increased or the same degree of reversibility at rest + GTN imaging compared to standard rest imaging. All defects with reduced reversibility at rest + GTN imaging (i.e. the remaining 18%) were, however, still reversible compared to the stress images. Some of this reduced reversibility may be due to attenuation artefacts. We conclude that the routine use of GTN with rest tetrofosmin imaging will result in increased detection of ischaemic areas with no loss of sensitivity or specificity.

  20. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  1. Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging

    DEFF Research Database (Denmark)

    Hansen, Thomas Fritz; Dirks, Christina G; Jensen, Gorm B;

    2004-01-01

    PURPOSE: To investigate the diagnostic ability of quantitative magnetic resonance imaging (MRI) heart perfusion in acute heart patients, a fast, multislice dynamic contrast-enhanced MRI sequence was applied to patients with acute myocardial infarction. MATERIALS AND METHODS: Seven patients...... slices, each having 60 sectors, provided an estimation of the severity and extent of the perfusion deficiency. Reperfusion was assessed both by noninvasive criteria and by coronary angiography (CAG). RESULTS: The Ki maps clearly delineated the infarction in all patients. Thrombolytic treatment...... was clearly beneficial in one case, but had no effect in the two other cases. Over the time-course of the study, normal perfusion values were not reestablished following thrombolytic treatment in all cases investigated. CONCLUSION: This study shows that quantitative MRI perfusion values can be obtained from...

  2. Myocardial perfusion scintigraphy in Germany. Results of the 2005 query and current status

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, O. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Burchert, W. [Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany); Arbeitsgemeinschaft ' ' Kardiovaskulaere Nuklearmedizin' ' der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Bengel, F.M. [Cardiovascular Nuclear Medicine, Johns Hopkins Medical Insts., Baltimore (United States); Arbeitsgruppe ' ' Nuklearkardiologische Diagnostik' ' der Deutschen Gesellschaft fuer Kardiologie (Germany); Zimmermann, R. [Arbeitsgruppe ' ' Nuklearkardiologische Diagnostik' ' der Deutschen Gesellschaft fuer Kardiologie (Germany); Medizinische Klinik, Klinikum Pforzheim GmbH (Germany); Dahl, J. vom [Klinik fuer Kardiologie, Kliniken Maria Hilf GmbH, Moenchengladbach (Germany); Schaefer, W.; Buell, U. [Klinik fuer Nuklearmedizin, Universitaetsklinikum Aachen (Germany); Schober, O. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster (Germany); Schwaiger, M. [Nuklearmedizinische Klinik, Klinikum Rechts der Isar, Muenchen (Germany); Kluge, R. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Leipzig (Germany); Schaefers, M. [Arbeitsgemeinschaft ' ' Kardiovaskulaere Nuklearmedizin' ' der Deutschen Gesellschaft fuer Nuklearmedizin (Germany); Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Muenster (Germany)

    2007-07-01

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine (DGN), in cooperation with the working group Nuclear Cardiology of the German Cardiac Society (DGK), decided to conduct a national survey on myocardial perfusion scintigraphy (MPS). Method: a questionnaire to evaluate MPS for the year 2005 was sent. Results: 346 completed questionnaires had been returned (213 private practices, 99 hospitals and 33 university hospitals). MPS of 112 707 patients were reported with 110 747 stress and 95 878 rest studies. The majority (> 75%) was performed with {sup 99m}Tc-MIBI or tetrofosmin. {sup 201}Tl stress-redistribution was used in 22 637 patients (20%). The types of stress were exercise in 78%, vasodilation with adenosine or dipyridamol in 21% and dobutamine in 1%. 99.97% of all MPS were SPECT studies. Gated SPECT was performed in 36% of the stress and in 32% of the rest studies. An attenuation correction was used in 21%. 29 institutions (8%) performed gated SPECT (stress and rest) and attenuation correction. 47% of all MPS were requested by ambulatory care cardiologists, 17% by internists, 12% by primary care physicians, 21% by hospital departments and 2% by others. Conclusion: in Germany, MPS is predominantly performed with {sup 99m}Tc-perfusion agents. The common type of stress is ergometry. Gated SPECT and attenuation correction do not yet represent standards of MPS practice in Germany, which indicates some potential of optimization. (orig.)

  3. Optimization of a protocol for myocardial perfusion scintigraphy by using an anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Susie Medeiros Oliveira; Sa, Lidia Vasconcellos de, E-mail: susie@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar [Clinica de Diagnostico Por Imagem (CDPI/DASA), Rio de Janeiro, RJ (Brazil)

    2014-07-15

    Objective: to develop a study aiming at optimizing myocardial perfusion imaging. Materials and Methods: imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The {sup 99m}Tc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. Results: the results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. Conclusion: the described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol. (author)

  4. Optimization of a protocol for myocardial perfusion scintigraphy by using an anthropomorphic phantom*

    Science.gov (United States)

    Ramos, Susie Medeiros Oliveira; Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar; de Sá, Lidia Vasconcellos

    2014-01-01

    Objective To develop a study aiming at optimizing myocardial perfusion imaging. Materials and Methods Imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The 99mTc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. Results The results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. Conclusion The described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol. PMID:25741088

  5. Ventricular dyssynchrony assessed by gated myocardial perfusion SPECT using a geometrical approach: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Veen, Berlinda J. van der; Younis, Imad Al [Leiden University Medical Centre, Department of Nuclear Medicine, Leiden (Netherlands); Ajmone-Marsan, Nina; Bax, Jeroen J. [Leiden University Medical Centre, Department of Cardiology, Leiden (Netherlands); Westenberg, Jos J.M.; Roos, Albert de [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Stokkel, Marcel P.M. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands)

    2012-03-15

    Left ventricular dyssynchrony may predict response to cardiac resynchronization therapy and may well predict adverse cardiac events. Recently, a geometrical approach for dyssynchrony analysis of myocardial perfusion scintigraphy (MPS) was introduced. In this study the feasibility of this geometrical method to detect dyssynchrony was assessed in a population with a normal MPS and in patients with documented ventricular dyssynchrony. For the normal population 80 patients (40 men and 40 women) with normal perfusion (summed stress score {<=}2 and summed rest score {<=}2) and function (left ventricular ejection fraction 55-80%) on MPS were selected; 24 heart failure patients with proven dyssynchrony on MRI were selected for comparison. All patients underwent a 2-day stress/rest MPS protocol. Perfusion, function and dyssynchrony parameters were obtained by the Corridor4DM software package (Version 6.1). For the normal population time to peak motion was 42.8 {+-} 5.1% RR cycle, SD of time to peak motion was 3.5 {+-} 1.4% RR cycle and bandwidth was 18.2 {+-} 6.0% RR cycle. No significant gender-related differences or differences between rest and post-stress acquisition were found for the dyssynchrony parameters. Discrepancies between the normal and abnormal populations were most profound for the mean wall motion (p value <0.001), SD of time to peak motion (p value <0.001) and bandwidth (p value <0.001). It is feasible to quantify ventricular dyssynchrony in MPS using the geometrical approach as implemented by Corridor4DM. (orig.)

  6. [Myocardial perfusion scintigraphy 2012 in Germany. Results of the 6th Query].

    Science.gov (United States)

    Lindner, O; Burchert, W; Schäfers, M; Schaefer, W

    2014-01-01

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 6th survey on myocardial perfusion scintigraphy (MPS) of the reporting year 2012. 278 questionnaires (177 private practices (PP), 78 hospitals (HO), 23 university hospitals (UH)) were evaluated. MPS of 105,941 patients were reported. 95% [2005 = 80%] of MPS studies were conducted with (99m)Tc perfusion radiopharmaceuticals and only 5% with 201Tl. 79% [2009 = 76%] of the MPS were performed in PP, 15% [2009 = 17%] in HO, and 6% [2009 = 7%] in UH. Data from 108 centres which participated in all surveys from 2005 to 2012 showed an increase in MPS numbers of 4.0% (PP +6.1%, HO +18.2%, UH -18.3%). 29% of all participants (27% of PP, 31% of HO, and 26% of UH) noticed no change and 26% of all participants (28% of PP, 17% of HO and 35% of UH) an increase in their MPS requests since the 2009 query. The type of stress was pharmacological in 39% [2009 = 31%]. Of these 61% with adenosine (39% with exercise), 22% with regadenoson (51% with exercise), 14% with dipyridamole (60% with exercise), and 3% with dobutamine. Gated SPECT was performed in 73% [2009 = 56%] of all rest, in 70% [2009 = 56%] of all stress and in 67% [47%] of all stress and rest MPS. Only 36% [2009 = 33%] of the centres performed a quantification of all their studies with scores, whereas 41% [2009 = 52%] did not apply any quantification. 60% [2009 = 49%] of the MPS were requested by ambulatory care cardiologists. The survey on MPS in Germany reveals a good conformity of imaging procedures with the current guideline. A positive development in MPS practice and referral can be stated. However, there is still some potential of MPS processing considering the quantitative perfusion analysis.

  7. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    Science.gov (United States)

    Rahman, Atiar

    2006-01-01

    Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (Pperfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  8. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    Energy Technology Data Exchange (ETDEWEB)

    Verberne, Hein J.; Eck-Smit, Berthe L.F. van; Wit, Tim C. de [University of Amsterdam, Department of Nuclear Medicine, F2-238, Academic Medical Center, Amsterdam (Netherlands); Acampa, Wanda [National Council of Research, Institute of Biostructures and Bioimaging, Naples (Italy); Anagnostopoulos, Constantinos [Academy of Athens, Center for Experimental Surgery, Clinical and Translational Research, Biomedical Research Foundation, Athens (Greece); Ballinger, Jim [Guy' s Hospital - Guy' s and St Thomas' Trust Foundation, Department of Nuclear Medicine, London (United Kingdom); Bengel, Frank [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Bondt, Pieter De [OLV Hospital, Department of Nuclear Medicine, Aalst (Belgium); Buechel, Ronny R.; Kaufmann, Philip A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Cuocolo, Alberto [University Federico II, Department of Advanced Biomedical Sciences, Naples (Italy); Flotats, Albert [Universitat Autonoma de Barcelona, Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Barcelona (Spain); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Hindorf, Cecilia [Skaane University Hospital, Department of Radiation Physics, Lund (Sweden); Lindner, Oliver [University Hospital of the Ruhr-University Bochum, Heart and Diabetes Center North Rhine-Westphalia, Institute for Radiology, Nuclear Medicine and Molecular Imaging, Bad Oeynhausen (Germany); Ljungberg, Michael [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Lonsdale, Markus [Bispebjerg Hospital, Department of Clinical Physiology and Nuclear Medicine, Copenhagen (Denmark); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Service Commun Investigations chez l' Homme, GIP Cyceron, Caen (France); Minarik, David [Skaane University Hospital, Radiation Physics, Malmoe (Sweden); Scholte, Arthur J.H.A. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Traegaardh, Elin [Skaane University Hospital and Lund University, Clinical Physiology and Nuclear Medicine, Malmoe (Sweden); Hesse, Birger [University Hospital of Copenhagen, Department of Clinical Physiology and Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-11-15

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/ publications/guidelines/2015{sub 0}7{sub E}ANM{sub F}INAL myocardial{sub p}erfusion{sub g}uideline.pdf. (orig.)

  9. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging; Quantification non invasive de l'heterogeneite de la perfusion du myocarde par analyse markovienne en imageries nucleaire SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Pons, G.

    2011-04-28

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  10. Erroneous cardiac ECG-gated PET list-mode trigger events can be retrospectively identified and replaced by an offline reprocessing approach: first results in rodents

    Science.gov (United States)

    Böning, Guido; Todica, Andrei; Vai, Alessandro; Lehner, Sebastian; Xiong, Guoming; Mille, Erik; Ilhan, Harun; la Fougère, Christian; Bartenstein, Peter; Hacker, Marcus

    2013-11-01

    The assessment of left ventricular function, wall motion and myocardial viability using electrocardiogram (ECG)-gated [18F]-FDG positron emission tomography (PET) is widely accepted in human and in preclinical small animal studies. The nonterminal and noninvasive approach permits repeated in vivo evaluations of the same animal, facilitating the assessment of temporal changes in disease or therapy response. Although well established, gated small animal PET studies can contain erroneous gating information, which may yield to blurred images and false estimation of functional parameters. In this work, we present quantitative and visual quality control (QC) methods to evaluate the accuracy of trigger events in PET list-mode and physiological data. Left ventricular functional analysis is performed to quantify the effect of gating errors on the end-systolic and end-diastolic volumes, and on the ejection fraction (EF). We aim to recover the cardiac functional parameters by the application of the commonly established heart rate filter approach using fixed ranges based on a standardized population. In addition, we propose a fully reprocessing approach which retrospectively replaces the gating information of the PET list-mode file with appropriate list-mode decoding and encoding software. The signal of a simultaneously acquired ECG is processed using standard MATLAB vector functions, which can be individually adapted to reliably detect the R-peaks. Finally, the new trigger events are inserted into the PET list-mode file. A population of 30 mice with various health statuses was analyzed and standard cardiac parameters such as mean heart rate (119 ms ± 11.8 ms) and mean heart rate variability (1.7 ms ± 3.4 ms) derived. These standard parameter ranges were taken into account in the QC methods to select a group of nine optimal gated and a group of eight sub-optimal gated [18F]-FDG PET scans of mice from our archive. From the list-mode files of the optimal gated group, we

  11. {sup 99m}Tc sestamibi myocardial perfusion scintigraphy with the novel use of metamizol for the detection of perfusion reversibility

    Energy Technology Data Exchange (ETDEWEB)

    Erguen, Eser Lay; Caglar, Meltem; Bozkurt, Murat Fani [Hacettepe University, Department of Nuclear Medicine, School of Medicine, Ankara (Turkey); Erguen, Hakan [Ankara University, Department of Pharmacology and Clinical Pharmacology, Faculty of Medicine, Ankara (Turkey)

    2008-08-15

    This study aims to investigate whether induction with metamizol, an analgesic-antipyretic drug having spasmolitic activity, could be used to increase the detectability of ischemic/jeopardized myocardium during MPS (myocardial perfusion scintigraphy). Metamizol-enhanced rest MPS (45 min after administration of 1 g metamizol orally, 740 MBq {sup 99m}Tc sestamibi was injected, MPS was acquired 45 min later) was performed in 21 patients who had perfusion defects on their previous stress-rest {sup 99m}Tc sestamibi MPS. Blood pressure was monitored at 15-min intervals. Stress, rest, metamizol-rest MPS images were interpreted on the model of 20 segments using a visual uptake score (VUS; 0 = normal, 1 = mild, 2 = moderate, 3 = significant decreases, 4 = no uptake). {sup 99m}Tc sestamibi uptake ratios (MIBI-UR; mean counts in the region of the perfusion defect/mean counts in the region of the normal-perfused wall) were obtained on each MPS and compared with each other. Average MIBI-UR in each scintigraphic examination was calculated. MPS were compared with coronary angiography results. VUS and MIBI-UR results showed that metamizol-rest MPS displayed the defect reversibility better than rest MPS. Of the 14 segments with fixed perfusion defects on stress-rest MPS, 8 showed improvement of perfusion after metamizol induction. In 33 segments, lesion reversibility was better delineated on metamizol-rest MPS. Metamizol-induced sestamibi uptake was significantly higher (p < 0.001) than stress/baseline rest examinations as calculated by the MIBI-UR. Blood pressure remained unaltered. Coronary angiography results were in concordance with metamizol induced MPS. Metamizol-enhanced rest MPS increases detectability of ischemic/viable myocardium during MPS. Metamizol should be discontinued like nitrates before stress MPS since it may mask the visualization of ischemic perfusion defects. (orig.)

  12. Myocardial perfusion quantification using the T1 -based FAIR-ASL method: the influence of heart anatomy, cardiopulmonary blood flow and look-locker readout.

    Science.gov (United States)

    Kampf, Thomas; Helluy, Xavier; Gutjahr, Fabian T; Winter, Patrick; Meyer, Cord B; Jakob, Peter M; Bauer, Wolfgang R; Ziener, Christian H

    2014-05-01

    The quantification of myocardial perfusion using a Look-Locker flow-sensitive alternating inversion recovery- arterial spin labeling experiment is considered. Due to the anatomy of the heart, a substantial but unintended partial inversion of the inflowing blood occurs during the slice-selective inversion. Both, the partial inversion as well as the Look-Locker pulse train, influence the myocardial perfusion quantification and are addressed in this work. The mean relaxation time approximation is used to calculate the monoexponential relaxation time of the signal in perfused tissue under Look-Locker readout. The left ventricular blood serves as an approximation of the inflowing blood in the description of FAIR-ASL measurements with global and slice-selective inversion to correctly quantify the myocardial perfusion. The analysis shows that the myocardial perfusion can be overestimated if the T1 -based quantification method is not adapted respecting the Look-Locker pulse train explicitly. Additionally, it turns out that without correction for the partial inversion of the blood pool during the slice-selective inversion the myocardial perfusion is underestimated. It is shown that the Look-Locker readout as well as the nonideal slice-selective inversion experiment have a considerable influence and have to be included properly to correctly quantify myocardial perfusion. Copyright © 2013 Wiley Periodicals, Inc.

  13. Evaluation of Respiratory Motion Effect on Defect Detection in Myocardial Perfusion SPECT: A Simulation Study.

    Science.gov (United States)

    Yang, Yu-Wen; Chen, Jyh-Cheng; He, Xin; Wang, Shyh-Jen; Tsui, Benjamin M W

    2009-06-01

    The objective of this study is to investigate the effects of respiratory motion (RM) on defect detection in Tc-99m sestamibi myocardial perfusion SPECT (MPS) using a phantom population that includes patient variability. Three RM patterns are included, namely breath-hold, slightly enhanced normal breathing, and deep breathing. For each RM pattern, six 4-D NCAT phantoms were generated, each with anatomical variations. Anterior, lateral and inferior myocardial defects with different sizes and contrasts were inserted. Noise-free SPECT projections were simulated using an analytical projector. Poisson noise was then added to generate noisy realizations. The projection data were reconstructed using the OS-EM algorithm with 1 and 4 subsets/iteration and at 1, 2, 3, 5, 7, and 10 iterations. Short-axis images centered at the centroid of the myocardial defect were extracted, and the channelized Hotelling observer (CHO) was applied for the detection of the defect. The CHO results show that the value of the area under the receiver operating characteristics (ROC) curve (AUC) is affected by the RM amplitude. For all the defect sizes and contrasts studied, the highest or optimal AUC values indicate maximum detectability decrease with the increase of the RM amplitude. With no respiration, the ranking of the optimal AUC value in decreasing order is anterior then lateral, and finally inferior defects. The AUC value of the lateral defect drops more severely as the RM amplitude increases compared to other defect locations. Furthermore, as the RM amplitude increases, the AUC values of the smaller defects drop more quickly than the larger ones. We demonstrated that RM affects defect detectability of MPS imaging. The results indicate that developments of optimal data acquisition methods and RM correction methods are needed to improve the defect detectability in MPS.

  14. Dietary red palm oil supplementation reduces myocardial infarct size in an isolated perfused rat heart model

    Directory of Open Access Journals (Sweden)

    Esterhuyse Adriaan J

    2010-06-01

    Full Text Available Abstract Background and Aims Recent studies have shown that dietary red palm oil (RPO supplementation improves functional recovery following ischaemia/reperfusion in isolated hearts. The main aim of this study was to investigate the effects of dietary RPO supplementation on myocardial infarct size after ischaemia/reperfusion injury. The effects of dietary RPO supplementation on matrix metalloproteinase-2 (MMP2 activation and PKB/Akt phosphorylation were also investigated. Materials and methods Male Wistar rats were divided into three groups and fed a standard rat chow diet (SRC, a SRC supplemented with RPO, or a SRC supplemented with sunflower oil (SFO, for a five week period, respectively. After the feeding period, hearts were excised and perfused on a Langendorff perfusion apparatus. Hearts were subjected to thirty minutes of normothermic global ischaemia and two hours of reperfusion. Infarct size was determined by triphenyltetrazolium chloride staining. Coronary effluent was collected for the first ten minutes of reperfusion in order to measure MMP2 activity by gelatin zymography. Results Dietary RPO-supplementation decreased myocardial infarct size significantly when compared to the SRC-group and the SFO-supplemented group (9.1 ± 1.0% versus 30.2 ± 3.9% and 27.1 ± 2.4% respectively. Both dietary RPO- and SFO-supplementation were able to decrease MMP2 activity when compared to the SRC fed group. PKB/Akt phosphorylation (Thr 308 was found to be significantly higher in the dietary RPO supplemented group when compared to the SFO supplemented group at 10 minutes into reperfusion. There was, however, no significant changes observed in ERK phosphorylation. Conclusions Dietary RPO-supplementation was found to be more effective than SFO-supplementation in reducing myocardial infarct size after ischaemia/reperfusion injury. Both dietary RPO and SFO were able to reduce MMP2 activity, which suggests that MMP2 activity does not play a major role in

  15. Effect of intracoronary injection of tirofiban combined with anisodamine on myocardial perfusion in patients with STEMI after PCI

    Institute of Scientific and Technical Information of China (English)

    Xiao-Gang Zhu; Li-Yue Wang; Hao-Jin Ren; Jin-Hua Liu

    2016-01-01

    Objective:To analyze the effect of intracoronary injection of tirofiban combined with anisodamine on myocardial perfusion in patients with STEMI after PCI.Methods:A total of 78 patients with acute ST segment elevation myocardial infarction (STEMI) who received PCI therapy in our hospital were randomly divided into control group and observation group, control group accepted routine PCI treatment, observation group received intracoronary injection of tirofiban and anisodamine in PCI, and myocardial perfusion of two groups was compared.Results: QRS duration values of observation group the instant after PCI and 4h after PCI were less than those of control group (P<0.05);99mTc-MIBI and18F-FDG intake of observation group after PCI were more than those of control group (P<0.05); serum MCP-1, sFas, Copeptin, OPN and vWF levels of observation group 4 h after PCI were lower than those of control group (P<0.05).Conclusions:Intracoronary injection of tirofiban combined with anisodamine can optimize myocardial perfusion in patients with STEMI after PCI, and has positive clinical significance.

  16. Impact of myocardial perfusion imaging on in-hospital coronary angiography and revascularization of patients with suspected coronary artery disease

    Institute of Scientific and Technical Information of China (English)

    HAN Ping-ping; HE Zuo-xiang; TIAN Yue-qin; FANG Wei; YANG Min-fu; ZHANG Xiao-li; SHEN Rui; SUN Xiao-xin; QIAO Shu-bin; YANG Yue-jin

    2011-01-01

    Background Noninvasive cardiac imaging is now central to the diagnosis and management of patients with moderate probability for coronary artery disease. The aim of this study was to assess the impact of stress myocardial perfusion single photon emission computerized tomography (SPECT) on in-hospital coronary angiography and revascularization for such patients.Methods Between January 2005 and June 2007, 1053 consecutive in-hospital patients (423 women, the average age of (57.2±11.2) years) with suspected coronary artery disease but without any prior interventional treatment were retrospectively analyzed. All patients underwent a 2-day stress/rest 99m Tc-methoxyisobutylisonitrile (MIBI) myocardial perfusion SPECT, including 984 exercise test and 69 adenosine test.Results Overall, stress/rest myocardial perfusion SPECT was normal in 973 patients (92.4%) and abnormal in 80 patients (7.6%). A total of 190 patients underwent coronary angiography, 46 underwent percutaneous coronary intervention and 10 coronary artery bypass grafting during hospitalization. From the whole perspective, only 14.7% of patients with normal SPECT underwent coronary angiography, so did 58.8% of patients with abnormal SPECT (x2=97.0,P<0.001); furthermore, the rates of revascularization in patients with normal and abnormal SPECT were 2.8% and 36.3%,respectively (27 out of 973 vs. 29 out of 80, x2=157.9, P<0.001). The extent and severity of ischemia did not add more predictive value for subsequent coronary angiography, but did have impact on revascularization. Multivariate analysis showed that reversible perfusion defect was the most predictive variable for referral rate to coronary angiography (odds ratio=7.5, P<0.001).Conclusions Abnormal myocardial perfusion SPECT is a powerful referral for in-hospital coronary angiography and revascularization during the same hospitalization. Thus, stress/rest SPECT is an effective gatekeeper for early coronary angiography and invasive treatment for

  17. Correlation of angina pectoris and perfusion decrease by collateral circulation in single-vessel coronary chronic total occlusion using myocardial perfusion single-photon emssion computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Park, Ki Seong; Kang, Sae Ryung [Chonnam National University Hospital, Gwangju (Korea, Republic of); and others

    2016-03-15

    To evaluate the perfusion decrease in donor myocardium by collateral circulation and its correlation with angina pectoris in patients with chronic total occlusion (CTO) using myocardial perfusion single-photon emission computed tomography (MPS). Thirty-six patients with single-vessel CTO without any other stenosis were included. All patients underwent MPS and coronary angiography (CAG) within 2 months. Total 72 donor arteries were evaluated for the grades of collaterals to the CTO artery using the Rentrop grading system on CAG. Perfusion defects and perfusion scores in donor and CTO territories were analyzed on MPS. Myocardial perfusion of donor and CTO territories were evaluated according to the presence of angina pectoris and the grades of collateral circulation. When the CTO territory was ischemic, symptomatic patients showed higher summed difference scores in the CTO territory compared to asymptomatic patients (3.5 ± 2.4 vs. 1.5 ± 0.8 for symptomatic and asymptomatic groups respectively; p = 0.034). However, when the CTO territory was nonischemic, symptomatic patients showed higher summed stress scores (SSS, 4.3 ± 2.9 vs. 1.6 ± 1.2; p = 0.032) and summed rest scores (SRS, 4.2 ± 2.5 vs. 1.5 ± 1.1; p = 0.003) in the donor territories. On the per-vessel analysis, perfusion defects in donor territories were more frequent (0 % vs. 53 % vs. 86 % for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p < 0.001) and showed higher SSS (0.0 ± 0.0, 1.3 ± 1.6 and 2.1 ± 1.1 for Rentrop 0, Rentrop 1–2 and Rentrop 3, respectively; p = 0.001) and SRS (0.0 ± 0.0, 1.0 ± 1.4 and 1.7 ± 1.2; p = 0.003) at higher Rentrop grades, but their patterns were variable. Angina pectoris was related to either ischemia of the myocardium beyond CTO or a perfusion decrease in the donor myocardium. The perfusion decrease in donor myocardium positively correlated with the collateral grades.

  18. Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany)], E-mail: dominik.ketelsen@med.uni-tuebingen.de; Thomas, Christoph; Werner, Matthias; Luetkhoff, Marie H. [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Buchgeister, Markus [Departments of Radiotherapy and Radiooncology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Tsiflikas, Ilias; Reimann, Anja [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Burgstahler, Christof [Department of Cardiology, University Hospital Tuebingen, Ottfried-Mueller-Strasse 10, 72076 Tuebingen (Germany); Brodoefel, Harald; Kopp, Andreas F.; Claussen, Claus D.; Heuschmid, Martin [Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany)

    2010-02-15

    Purpose: The aim of the study was to estimate radiation exposure of coronary calcium scoring and angiography using ECG-gated and ECG-triggered dual-source computed tomography. Materials and methods: An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for all dose measurements. Effective dose was calculated according to ICRP 103. Radiation exposure was performed on a dual-source computed tomography (DSCT) scanner with standard protocols for calcium scoring (DSCT-Ca) and coronary angiography (DSCTA) at different heart rates (40-100 beats/min). Furthermore, a scanning protocol with ECG-triggering as well as a standard chest CT scan were evaluated. Results: Depending on gender, heart rate and ECG-pulsing, the effective dose of a complete cardiac DSCT (DSCT-Ca and DSCTA) scan varies from 10.2 to 32.6 mSv. The effective radiation dose increased significantly with lower heart rates (p < 0.035). ECG-pulsing reduced the radiation exposure significantly in DSCTA (p < 0.001). Due to breast tissue in the primary scan range, females' doses showed an increase up to 69.9% compared to males in scan protocols without ECG-pulsing. Prospective ECG-triggered DSCTA resulted in estimated effective doses from 2.8 mSv (males) to 4.1 mSv (females). Conclusion: The ECG-pulsing technique has proven its effectiveness to reduce effective dose in coronary CT angiography and is recommended for all patients with regular heart rates. The patient's heart rate influences the radiation exposure with a significant decrease at higher heart rates. Due to its lower dose, ECG-triggered DSCTA should be implemented for special indications, i.e. for diagnosis of pathologies of the aortic root and the ascending aorta.

  19. Comparison of the veracity of real-time perfusion, harmonic angio, and ultraharmonic myocardial contrast imaging modes in evaluation of acute myocardial infarction area

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Innovative advancements in ultrasound instrumentation present a number of imaging modalities for myocardial contrast echocardiography (MCE) in ischemic syndromes. How well they compare to each other in diagnostic accuracy in the detection of acute myocardial infarction is unclear. The purpose of this study was to assess the relative accuracy of 3 different imaging modes of MCE, low mechanical index (MI) real-time perfusion imaging (RTPI), triggered harmonic angio mode (HA), and ultraharmonic imaging mode (UH) in the detection of acute experimental myocardial infarction within the time frame suitable for potential reperfusion. Methods MCE was performed in 10 open-chest dogs using RTPI, triggered HA and triggered UH modes at baseline and one hour after occlusion of left anterior descending coronary artery. Presence or absence of perfusion defects, and the perfusion defect size when present, were analyzed and compared with the infarct size delineated by triphenyltetrazolium chloride(TTC)staining. Results The infarct area was (15.8±2.4)% by TTC staining; Perfusion defect area by MCE was similar to anatomic infarct area in all the three MCE approaches: (16.1±2.7)% by RTPI mode, (15.5±2.9)% by HA mode, and (15.5±3.0)% by UH mode. The sensitivity, specificity and overall diagnostic accuracy in the detection of myocardial infarction were 100%, 88%, and 94% for RTPI mode, 88%, 100%, and 94 % for HA mode, and 100%, 75%, and 88% for UH mode. Conclusion All modes of MCE, RTPI, triggered HA mode and triggered UH mode have excellent diagnostic accuracy in the immediate hour of acute coronary occlusion within the optimal time frame suitable for reperfusion therapy.

  20. Correlation of myocardial perfusion scintigraphy and coronary angiography; Korrelation der Myokardszintigraphie mit der Koronarangiographie

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T. [Freiburg Univ. (Germany). Abt. Klinische Nuklearmedizin

    1999-06-01

    Discrepancy in findings of coronary angiography and myocardial perfusion-SPECT mostly reflect the hemodynamic effect of the pathological coronary morphology rather than misinterpretation by welltrained nuclear medicine physicians. Thus, perfusion scintigraphy gives a valuable completion of the angiographic findings. Consequently, forecast of coronary stenoses loses importance. The intention of cardiovascular medicine focuses more and more on functional statements. The detection of ischemia is not enough for correlated evaluation of SPECT/PET and coronary angiography. At least, assignment of perfusion defects and vascular territories is necessary. Quantitative evaluation and display of bull's eye are helpful and superior to visual interpretation. Due to the variability of the coronary vascular tree, assignment of angiographic and scintigraphic findings may sometimes remain ambiguous. Moreover, in patients with multivessel disease the detection of less stenosed vessels can be hidden if the stress tolerance is limited by the most severe stenosis. Other factors like morphology, length, and location of a stenosis, collaterals and endothelial dysfunction may also modify myocardial perfusion. Thus 'sensitivity' and 'specificity' of assignment of ischemia to a vascular territory ranges between 62% and 86%. With respect to a high-quality standard of the examinations and to the methodical limitations, head to head comparison of scintigraphic and angiographic images enable evaluation of the hemodynamic consequences of stenoses of a distinct coronary artery. The discrepancy of scintigraphic and angiographic findings in particular can lead to more reliable conclusions than the single examination does with direct impact on decision-making regarding medical or invasive therapy, complete or partial revascularization, and the selection of the vessel which has to be revascularized. Correlation of scintigraphy and angiography enables an individual planning of

  1. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas A; Hasbak, Philip; Larsson, Henrik B W

    2014-01-01

    INTRODUCTION: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). MATERIALS AND METHODS: Fourteen patients with coronary artery stenosis underwent ...

  2. THE VALUE OF 99mTc-MIBI MYOCARDIAL PERFUSION SPECT IMAGING IN DETECTING CORONARY ARTERY DISEASE IN PATIENTS WITH VALVULAR DISEASE BEFORE OPERATION

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective. The aim of this study was to detect coronary artery disease using99m Tc-MIBI myocardial perfusion imaging in patients with valvular disease.Methods. Thirty patients with valvular disease confirmed by echocardiography underwent 99mTc-MIBI myocardial perfusion imaging using multiSPECT 1h after stress test (exercise, dipyridamole or dobutamine test) and were performed coronary angiography within 1 month before valvular operation.Results.For 29 out of the 30 patients, the results of 99mTc-MIBI myocardial perfusion imaging were similar with those of coronary angiography, the concordance rate was 96.7% and the negative predictability was 100%.Conclusion.99m Tc-MIBI myocardial perfusion imaging is a reliable non-invasive method for detecting coronary artery disease in patients with valvular disease and so as to draw up suitable operation programs for them.

  3. Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia M., E-mail: investigacion@diagnosticomaipu.com.ar; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López Munain, Marina de; Vallejos, Javier; Tajer, Carlos; Rodriguez-Granillo, Gaston A.

    2015-04-15

    Highlights: •We evaluated myocardial perfusion by dual energy computed tomography (DECT). •We included patients with intermediate to high likelihood of coronary artery disease. •Stress myocardial perfusion by DECT had a reliable accuracy for the detection of ischemia. •Stress myocardial perfusion with DECT showed an incremental value over anatomical evaluation. •DECT imaging was associated to a significant reduction in radiation dose compared to SPECT. -- Abstract: Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80–0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65–0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.

  4. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C

    2016-01-01

    (MPR) in humans. We aimed to test the hypothesis that MPR in all myocardial layers is determined by age, gender, and cardiovascular risk profile in patients with ischaemic symptoms or equivalent but without obstructive coronary artery disease (CAD). METHODS AND RESULTS: A total of 149 patients enrolled...... in endocardial-epicardial distribution of perfusion reserve may be demonstrated with static CT perfusion. Low MPR in all myocardial layers was observed specifically in obese patients....

  5. Relationship between HgbA1c and Myocardial Blood Flow Reserve in Patients with Type 2 Diabetes Mellitus: Noninvasive Assessment Using Real-Time Myocardial Perfusion Echocardiography

    Directory of Open Access Journals (Sweden)

    Runqing Huang

    2014-01-01

    Full Text Available To study the relationship between glycosylated hemoglobin (HgbA1c and myocardial perfusion in type 2 diabetes mellitus (T2DM patients, we prospectively enrolled 24 patients with known or suspected coronary artery disease (CAD who underwent adenosine stress by real-time myocardial perfusion echocardiography (RTMPE. HgbA1c was measured at time of RTMPE. Microbubble velocity (β min−1, myocardial blood flow (MBF, mL/min/g, and myocardial blood flow reserve (MBFR were quantified. Quantitative MCE analysis was feasible in all patients (272/384 segments, 71%. Those with HgbA1c > 7.1% had significantly lower βreserve and MBFR than those with HgbA1c ≤ 7.1% (P 2 as normal, HgbA1c > 7.1% significantly increased the risk for abnormal MBFR, (adjusted odds ratio: 1.92, 95% CI: 1.12–3.35, P=0.02. Optimal glycemic control is associated with preservation of MBFR as determined by RTMPE, in T2DM patients at risk for CAD.

  6. The amount of viable and dyssynchronous myocardium is associated with response to cardiac resynchronization therapy: initial clinical results using multiparametric ECG-gated [{sup 18}F]FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, Sebastian; Uebleis, Christopher; Haug, Alexander; Bartenstein, Peter [University of Munich, Department of Nuclear Medicine, Munich (Germany); Schuessler, Franziska; Kaeaeb, Stefan; Estner, Heidi [University of Munich, Medical Department I, Munich (Germany); Van Kriekinge, Serge D.; Germano, Guido [UCLA, Cedars-Sinai Medical Center, Los Angeles and David Geffen School of Medicine, Los Angeles, CA (United States); Hacker, Marcus [Medical University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Theraphy, Vienna (Austria)

    2013-12-15

    There is still a significant amount of patients who do not sufficiently respond to cardiac resynchronization therapy (CRT). Previous studies demonstrated that the amount of dyssynchronous myocardium was predictive of response to CRT. Otherwise, non-response is frequently associated with high amounts of scar tissue. The combination of these parameters might yield a more accurate prediction of response. We hypothesized that the probability of a CRT response increases with the presence of high amounts of ''viable and dyssynchronous'' myocardium. A total of 19 patients (17 male, 61 {+-} 10 years) underwent ECG-gated [{sup 18}F]fluorodeoxyglucose (FDG) myocardial positron emission tomography (PET) before CRT device implantation and were followed for 6 months. Response to CRT was defined as clinical improvement of at least one New York Heart Association (NYHA) class in combination with left ventricular (LV) ejection fraction (EF) improvement of >5 %. Twelve responders (71 %) and seven non-responders (29 %) were identified. For each patient bullseye maps of FDG uptake and phase analysis were calculated (QPS/QGS 2012, Cedars-Sinai, Los Angeles, CA, USA) and fused. Amounts of myocardium representing ''viable and synchronous'', ''scar and synchronous'', viable and dyssynchronous or ''scar and dyssynchronous'' myocardium were quantified by planimetric measurements of the fused bullseye maps. Responders by definition showed significant decrease in NYHA class and significant increase of LVEF. Furthermore, a significantly higher amount of viable and dyssynchronous myocardium was found as compared to non-responders (21 {+-} 13 % vs 6 {+-} 5 %; p < 0.05). Combined assessment of myocardial viability and LV dyssynchrony is feasible using multiparametric [{sup 18}F]FDG PET and could improve conventional response prediction criteria for CRT. (orig.)

  7. Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte H; Menashi, Changez A K; Andersen, Ulrik B;

    2013-01-01

    BACKGROUND: Recently introduced iterative reconstruction algorithms with resolution recovery (RR) and noise-reduction technology seem promising for reducing scan time or radiation dose without loss of image quality. However, the relative effects of reduced acquisition time and reconstruction...... software have not previously been reported. The aim of the present study was to investigate the influence of reduced acquisition time and reconstruction software on quantitative and qualitative myocardial perfusion single photon emission computed tomography (SPECT) parameters using full time (FT) and half...... time (HT) protocols and Evolution for Cardiac Software. METHODS: We studied 45 consecutive, non-selected patients referred for a clinically indicated routine 2-day stress/rest (99m)Tc-Sestamibi myocardial perfusion SPECT. All patients underwent an FT and an HT scan. Both FT and HT scans were processed...

  8. Effect of intracoronary tirofiban on platelet alpha-granule membrane protein and myocardial perfusion level during emergency percutaneous coronary intervention.

    Science.gov (United States)

    Xu, H P; Liu, C M; Zhang, W W

    2014-11-14

    This study aimed to investigate the effect of intracoronary application of tirofiban on platelet alpha-granule membrane protein (GMP-140) and myocardial perfusion levels during emergency percutaneous coronary intervention (PCI). A total of 70 patients who accepted emergency PCI treatment were randomly divided into tirofiban and control groups. We determined GMP-140 and troponin I (cTnI) levels before and 12 h after surgery, as well as N-terminal pro-brain natriuretic peptide levels 1 and 7 days after surgery in the two groups. The results showed that GMP-140 and cTnI levels were significantly (P emergency PCI clearly reduced the GMP-140 level, inhibited the activation function of platelets, improved myocardial perfusion, and helped recover cardiac function in patients.

  9. Retraction: Selective cerebro-myocardial perfusion under mild hypothermia during primary repair for aortic coarctation with ventricular septal defect.

    Science.gov (United States)

    2013-04-01

    The following article from Artificial Organs, "Selective Cerebro-Myocardial Perfusion Under Mild Hypothermia During Primary Repair for Aortic Coarctation With Ventricular Septal Defect" by Huiwen Chen, Haifa Hong, Zhongqun Zhu and Jinfen Liu, published online on 2 November 2012 in Wiley Online Library (wileyonlinelibrary.com), has been retracted by agreement between the authors, the journal Editor-in-Chief, Paul S. Malchesky, the International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc. The retraction has been agreed due to simultaneous publication of a substantially similar article, "Continuous Cerebral and Myocardial Perfusion During One-Stage Repair for Aortic Coarctation With Ventricular Septal Defect", by Huiwen Chen, Haifa Hong, Zhongqun Zhu and Jinfen Liu, in Pediatric Cardiology 7 November 2012 [Epub ahead of print].

  10. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Y [National Cheng Kung University, Tainan, Taiwan (China); Huang, H [Chang Gung University, Taoyuan, Taiwan (China); Su, T [Chang Gung Memorial Hospital, Taoyuan, Taiwan (China)

    2015-06-15

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination

  11. CARDIAC RESYNCHRONIZATION THERAPY AND MYOCARDIAL PERFUSION OF THE LEFT AND RIGHT VENTRICLES

    Directory of Open Access Journals (Sweden)

    E. N. Ostroumov

    2012-01-01

    Full Text Available The decision to install cardiac resynchronization device in patients may be associated not with the apparent clini- cal effectiveness, but for other reasons that require medical consultation. This may be due to the need to create a «bridge» to heart transplantation (HT, for example. In order to predict the outcome of CRT, we observed 54 pa- tients with HF, III–IV functional class NYHA, on the waiting list for HT. Cardiomyopathy was diagnosed in 36 patients, various forms of ischemic heart disease was diagnosed in 17 patients, all with the ECG determined left bundle branch block with QRS complex duration of less than 120 ms. All patients performed gated SPECT before and after CRT with standard methods of research. LVEF at baseline did not exceed 35%. Monitoring was continued for 2 years after the start of the CRT. The results were divided into two groups. Group 1 consisted of patients who need HT for 2 years, in spite of the CRT (11 patients. Group 2 consisted of patients who have an increase in LVEF of at least 10% after CRT (28 patients. When comparing the initial and final performance with the help of the Main- Whitney in both groups, most significant differences were found in the assessment of myocardial perfusion relation- ships lateral walls of LV and RV. The decrease in the ratio between the level of perfusion of the lateral walls of LV and RV < 2,0 reduces the effectiveness of CRT, and within two years, there occured a need for a heart transplant. 

  12. Applying the J-optimal channelized quadratic observer to SPECT myocardial perfusion defect detection

    Science.gov (United States)

    Kupinski, Meredith K.; Clarkson, Eric; Ghaly, Michael; Frey, Eric C.

    2016-03-01

    To evaluate performance on a perfusion defect detection task from 540 image pairs of myocardial perfusion SPECT image data we apply the J-optimal channelized quadratic observer (J-CQO). We compare AUC values of the linear Hotelling observer and J-CQO when the defect location is fixed and when it occurs in one of two locations. As expected, when the location is fixed a single channels maximizes AUC; location variability requires multiple channels to maximize the AUC. The AUC is estimated from both the projection data and reconstructed images. J-CQO is quadratic since it uses the first- and second- order statistics of the image data from both classes. The linear data reduction by the channels is described by an L x M channel matrix and in prior work we introduced an iterative gradient-based method for calculating the channel matrix. The dimensionality reduction from M measurements to L channels yields better estimates of these sample statistics from smaller sample sizes, and since the channelized covariance matrix is L x L instead of M x M, the matrix inverse is easier to compute. The novelty of our approach is the use of Jeffrey's divergence (J) as the figure of merit (FOM) for optimizing the channel matrix. We previously showed that the J-optimal channels are also the optimum channels for the AUC and the Bhattacharyya distance when the channel outputs are Gaussian distributed with equal means. This work evaluates the use of J as a surrogate FOM (SFOM) for AUC when these statistical conditions are not satisfied.

  13. 320层容积CT心肌灌注成像对心肌灌注缺损的诊断价值%Detection of myocardial perfusion defect with 320-row volume CT myocardial perfusion imaging

    Institute of Scientific and Technical Information of China (English)

    张传臣; 张兆琪; 王蒨; 徐磊; 于薇; 焦健; 王瑞

    2012-01-01

    目的 探讨320层容积CT心肌灌注成像(CT-MPI)的可行性及其对心肌灌注缺损的诊断价值.方法 对14例经SPECT心肌灌注成像(SPECT-MPI)阳性的已知或可疑冠心病患者行静息和腺苷负荷320层容积CT-MPI检查,使用专用心肌灌注软件对CT-MPI进行分析.以心肌16节段标准分段方法(心尖除外)分别分析核素和容积CT-MPI的固定或可逆性灌注缺损.以SPECT-MPI为参考标准评价CT-MPI对心肌灌注缺损诊断的敏感度、特异度.结果 所有患者均成功完成320层容积CT-MPI.SPECT-MPI显示14例患者中共有39段心肌出现固定或可逆性灌注缺损,CT-MPI正确显示了其中12例患者的34段心肌灌注缺损.320层容积CT-MPI诊断心肌灌注缺损的敏感度、特异度分别为87.2%( 34/39)和91.4%(169/185).结论 320层容积CT-MPI对诊断心肌灌注缺损有较高的敏感度和特异度.%Objective To evaluate the feasibility of 320-row volume CT myocardial perfusion imaging (CT-MPI) in detecting myocardial perfusion defect.Methods Fourteen patients with positive single-positron emission computed tomography myocardial perfusion imaging (SPECT-MPI) findings underwent both rest and adenosine stress 320-row volume CT-MPI.Rest and stress CT perfusion images were analyzed by employing dedicated software in 320-row CT workstation.Both SPECT-MPI and CT-MPI were evaluated for fixed and reversible perfusion defects using a 16-segment model (apex was excluded).The sensitivity,specificity of 320-row volume CT-MPI in detecting myocardial perfusion defect were evaluated by taking SPECT-MPI as a reference standard.Results Both rest and stress 320-row volume CT-MPI were successfully performed in all patients.Thirty nine segments with fixed or reversible perfusion defects in all patients were depicted by SPECT-MPI,while 34 perfusion defects in 12 patients were identified by CT-MPI.The sensitivity,specificity of 320-row volume CT-MPI for detection of perfusion defects were 87.2

  14. Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: Comparison with retrospective ECG gating

    Energy Technology Data Exchange (ETDEWEB)

    Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yang Lin, E-mail: anna7949@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Li Yu, E-mail: athen06@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Xiaohai, E-mail: maxi8238@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lv Biao, E-mail: biao_lu2007@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2010-11-15

    Purpose: To explore feasibility of dual-source CT (DS-CT) prospective ECG-gated coronary angiography in patients with heart rate (HR) higher than 70 beat per minute (bpm), and evaluate image quality and radiation dose with comparison to retrospective ECG-gated spiral scan. Materials and methods: One hundred patients who underwent DS-CT coronary angiography (DS-CTCA) with mean HR higher than 70 bpm but below 110 bpm were enrolled in the study, 50 were scanned by adaptive sequential scan and another 50 were analyzed by retrospectively gated CT scan. The imaging quality of coronary artery segments in the two groups was evaluated using a four-point grading scale by two independent reviewers. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. Results: There was no significant difference between the two groups for mean HR (p = 0.305), HR variability (p = 0.103), body mass index (p = 0.472), and scan length (p = 0.208). There was good agreement for image quality scoring between the two reviewers (Kappa = 0.72). Coronary evaluability of adaptive sequential scan was 99.7% (608 of 610 segments), while that of retrospective gated scan was 98.7% (614 of 622 segments), showing similar coronary evaluability (p = 0.061). Effective doses of adaptive sequential scan and retrospective gated scan were 5.1 {+-} 1.6 and 11.8 {+-} 4.5 mSv, respectively (p < 0.001), showing that adaptive sequential scan reduced radiation dose by 57% compared with that of retrospective gated scan. Conclusions: In patients with 70-110 bpm HR, DS-CTCA adaptive sequential scan shows similar image quality as retrospective ECG-gated spiral scan with 57% reduction of radiation dose.

  15. Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospectively ECG-gated image reconstruction technique. Comparison with angiographic results

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yuichi; Matsumoto, Naoya; Kato, Masahiko [Nihon Univ., Tokyo (Japan). Surugadai Hospital] [and others

    2003-04-01

    The present study was designed to investigate the accuracy of multislice spiral computed tomography (MSCT) in detecting coronary artery disease, compared with coronary angiography (CAG), using a new retrospectively ECG-gated reconstruction method that reduced cardiac motion artifact. The study group comprised 54 consecutive patients undergoing MSCT and CAG. MSCT was performed using a SOMATOM Volume Zoom (4-detector-row, Siemens, Germany) with slice thickness 1.0 mm, pitch 1.5 (table feed: 1.5 mm per rotation) and gantry rotation time 500 ms. Metoprolol (20-60 mg) was administered orally prior to MSCT imaging. ECG-gated image reconstruction was performed with the reconstruction window (250 ms) positioned immediately before atrial contraction in order to reduce the cardiac motion artifact caused by the abrupt diastolic ventricular movement occurring during the rapid filling and atrial contraction periods. Following inspection of the volume rendering images, multiplanar reconstruction images and axial images of the left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) were obtained and evaluated for luminal narrowing. The results were compared with those obtained by CAG. Of 216 coronary arteries, 206 (95.4%) were assessable; 10 arteries were excluded from the analysis because of severe calcification (n=4), stents (n=3) or insufficient contrast enhancement (n=3). The sensitivity to detect coronary stenoses {>=}50% was 93.5% and the specificity to define luminal narrowing <50% was 97.2%. The positive predictive value and the negative predictive value were 93.5% and 97.2%, respectively. The sensitivity was still satisfactory (80.6%) even when non-assessable arteries were included in the analysis. The new retrospectively ECG-gated reconstruction method for MSCT has excellent diagnostic accuracy in detecting significant coronary artery stenoses. (author)

  16. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies

    Science.gov (United States)

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans—each containing 1/8th of the total number of events—were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other

  17. Cardiac risk stratification with myocardial perfusion imaging in potential renal-pancreas transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, M.C.; Larcos, G.; Chapman, J. [Westmead Hospital, Westmead, Sydney, NSW (Australia). Departments of Nuclear Medicine and Ultrasound

    1998-06-01

    Full text: Combined renal/pancreas transplantation is used in patients with severe type-1 diabetes and renal failure. Many patients have asymptomatic coronary artery disease (CAD). Thus, myocardial perfusion imaging (MPI) is widely used for preoperative risk assessment, however, its value has recently been challenged. The purpose of this study was to determine the predictive value of MPI compared to coronary angiography and/or thirty day perioperative cardiac events (cardiac death, myocardial infarction and unstable angina). We reviewed the MPI in 132 patients that were referred for possible renal pancreas transplantation during the period between 1987 - June 1997. Fifty five patients were excluded because of: still awaiting transplantation (n=19) ongoing medical assessment (n=21), received kidney only transplant (n=6) or other factors (n=9). Thus, 77 patients form the basis of this report. Seventy one patients were transplanted, 5 had coronary angiography and one died before transplantation but with coronary anatomy defined at autopsy. All patients (39 male, 38 female; mean age 37 years) had Tl-201 or Tc-99m MIBI SPECT at Westmead (n=54) or elsewhere (n=23). Patients underwent MPI, a mean of 12.1 months before transplantation and a mean of 6 months before coronary angiography or autopsy. MPI was normal in 64 (83%) and abnormal in 13 (17%) patients. Of the abnormal MPI, 7 patients had CAD and one had unstable angina post-operatively (PPV = 8/13; 61%). One patient had a fixed defect post CABG but proceeded to transplant with-out event; the other 4 patients had normal coronary anatomy. Of the normal MPIs there were no transplant related cardiac events, but one patient required CABG >12 months post MPI and a further patient died >12 months post transplant and was shown to have CAD at autopsy (NPV=62/64;97%). In conclusion we have found an excellent NPV and an acceptable PPV for MPI in potential renal pancreas graft recipients

  18. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  19. Septal myocardial perfusion imaging with thallium-201 in the diagnosis of proximal left anterior descending coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pichard, A.D.; Wiener, I.; Martinez, E.; Horowitz, S.; Patterson, R.; Meller, J.; Goldsmith, S.J.; Gorlin, R.; Herman, M.V.

    1981-07-01

    The use of myocardial perfusion imaging (MPI) to identify obstructive coronary disease of the left anterior descending coronary artery proximal to the first septal perforator (prox LAD) was studied in 60 patients. Perfusion of the septum and anteroapical areas with thallium-201 injected during exercise was compared to results of coronary arteriography. Septal MPI defect was found in 92.3% of patients with obstruction of the proximal LAD, 27.7% of patients with obstruction of LAD distal to first septal perforator, 0% in patients with obstructions involving right or circumflex arteries, and in 10.5% of patients without coronary disease. Anteroapical MPI defects were found with similar frequency in the three groups with obstructive coronary disease. Septal MPI defect had a sensitivity of 92.3% and specificity of 85.4% in the diagnosis of proximal LAD disease. Normal septal perfusion with thallium-201 virtually excluded proximal LAD disease.

  20. Role of Perfusion at Rest in the Diagnosis of Myocardial Infarction Using Vasodilator Stress Cardiovascular Magnetic Resonance.

    Science.gov (United States)

    Patel, Mita B; Mor-Avi, Victor; Kawaji, Keigo; Nathan, Sandeep; Kramer, Christopher M; Lang, Roberto M; Patel, Amit R

    2016-04-01

    In clinical practice, perfusion at rest in vasodilator stress single-photon emission computed tomography is commonly used to confirm myocardial infarction (MI) and ischemia and to rule out artifacts. It is unclear whether perfusion at rest carries similar information in cardiovascular magnetic resonance (CMR). We sought to determine whether chronic MI is associated with abnormal perfusion at rest on CMR. We compared areas of infarct and remote myocardium in 31 patients who underwent vasodilator stress CMR (1.5 T), had MI confirmed by late gadolinium enhancement (LGE scar), and coronary angiography within 6 months. Stress perfusion imaging during gadolinium first pass was followed by reversal with aminophylline (75 to 125 mg), rest perfusion, and LGE imaging. Resting and peak-stress time-intensity curves were used to obtain maximal upslopes (normalized by blood pool upslopes), which were compared between infarcted and remote myocardial regions of interest. At rest, there was no significant difference between the slopes in the regions of interest supplied by arteries with and without stenosis >70% (0.31 ± 0.16 vs 0.26 ± 0.15 1/s), irrespective of LGE scar. However, at peak stress, we found significant differences (0.20 ± 0.11 vs 0.30 ± 0.22 1/s; p rest, there was no difference between infarcted and remote myocardium (0.27 ± 0.14 vs 0.30 ± 0.17 1/s), irrespective of stenosis, but significant differences were seen during stress (0.21 ± 0.16 vs 0.28 ± 0.18 1/s; p rest associated with chronic MI are not reliably detectable on CMR images. Accordingly, unlike single-photon emission computed tomography, normal CMR perfusion at rest should not be used to rule out chronic MI.

  1. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  2. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva [Inst. of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr-Univ. Bochum, Bad Oeynhausen (Germany); Elsner, Andreas; Bolte, Matthias; Domik, Gitta [Research Group Computergraphics, Visualization and Image Processing, Univ. of Paderborn (Germany); Hoff, Joerg van den [PET Center, Inst. of Radiopharmacy, Research Center Rossendorf, Dresden (Germany)

    2009-07-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  3. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Monbaron, David; Ruiz, Juan [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland); Koehli, Melanie [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland)

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, {sup 99m}Tc-sestamibi, {sup 201}Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS{>=}4) was observed in 49 (37%) patients (SSS=4.9{+-}8.4, SDS=2.4{+-}4.7), reversible perfusion defects (SDS{>=}2) in 40 (30%) patients [SSS=13.3{+-}10.9; SDS=8.0{+-}5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9{+-}11.3; SDS=7.4{+-}1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify

  4. Adding attenuation corrected images in myocardial perfusion imaging reduces the need for a rest study.

    Science.gov (United States)

    Trägårdh, Elin; Valind, Sven; Edenbrandt, Lars

    2013-04-01

    The American Society of Nuclear Cardiology and the Society of Nuclear Medicine conclude that incorporation of attenuation corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve diagnostic accuracy. The aim was to investigate the value of adding AC stress-only images for the decision whether a rest study is necessary or not. 1,261 patients admitted to (99m)Tc MPS were studied. The stress studies were interpreted by two physicians who judged each study as "no rest study necessary" or "rest study necessary", by evaluating NC stress-only and NC + AC stress-only images. When there was disagreement between the two physicians, a third physician evaluated the studies. Thus, agreement between 2 out of 3 physicians was evaluated. The physicians assessed 214 more NC + AC images than NC images as "no rest study necessary" (17% of the study population). The number of no-rest-study-required was significantly higher for NC + AC studies compared to NC studies (859 vs 645 cases (p rest study necessary" (22 NC + AC cases; 8 NC cases), (no statistically significant difference). In 11 of these, the final report stated "suspected/possible ischemia or infarction in a small area". Adding AC stress-only images to NC stress-only images reduce the number of unnecessary rest studies substantially.

  5. Long-term mortality following normal exercise myocardial perfusion SPECT according to coronary disease risk factors.

    Science.gov (United States)

    Rozanski, Alan; Gransar, Heidi; Min, James K; Hayes, Sean W; Friedman, John D; Thomson, Louise E J; Berman, Daniel S

    2014-04-01

    While normal exercise myocardial perfusion imaging (SPECT-MPI) is a robust predictor of low short-term clinical risk, there is increasing interest in ascertaining how clinical factors influence long-term risk following SPECT-MPI. We evaluated the predictors of outcome from clinical data obtained at the time of testing in 12,232 patients with normal exercise SPECT-MPI studies. All-cause mortality (ACM) was assessed at a mean of 11.2 ± 4.5 years using the Social Security Death Index. The ACM rate was 0.8%/year, but varied markedly according to the presence of CAD risk factors. Hypertension, smoking, diabetes, exercise capacity, dyspnea, obesity, higher resting heart rate, an abnormal ECG, LVH, atrial fibrillation, and LVEF rates ranged from only 0.2%/year among patients exercising for >9 minutes having none of three significant risk factors (among hypertension, diabetes, and smoking) to 1.6%/year among patients exercising 9 minutes and had no significant risk factors (P term mortality risk varies markedly in accordance with baseline CAD risk factors and functional capacity among patients with normal exercise SPECT-MPI studies. Further study is indicated to determine whether the prospective characterization of both short-term and long-term risks following the performance of stress SPECT-MPI leads to improved clinical management.

  6. Myocardial perfusion imaging with technetium-99m SQ30217: Comparison with thallium-201 and coronary anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Seldin, D.W.; Johnson, L.L.; Blood, D.K.; Muschel, M.J.; Smith, K.F.; Wall, R.M.; Cannon, P.J.

    1989-03-01

    Myocardial perfusion in ten normal volunteers and 20 patients with coronary artery disease documented by recent coronary arteriography was studied with 99mTc-labeled SQ30217 and /sup 201/TI. Plantar /sup 201/TI imaging followed standard treadmill exercise and planar SQ30217 imaging followed upright bicycle exercise, performed to angina, or the same double product achieved on the treadmill test. Upright anterior, 30 degrees left anterior oblique, and 60 degrees left anterior oblique images were obtained for 3, 6, and 9 min, respectively, starting 2 min after injection of 15 mCi of 99mTc SQ30217. A second 15-mCi dose was injected at rest approximately 2 hr later, and the same imaging protocol was followed. No adverse reactions or laboratory abnormalities attributable to SQ30217 were observed. All scans on the normal volunteers were interpreted as normal. Qualitative readings of both tests were equally sensitive for detecting patients with coronary disease (SQ30217 - 16/20, TI - 17/20, p = NS) and identifying abnormal vessels (SQ30217 - 19/45, TI - 21/45, p = NS). Both agents were falsely positive in 1/15 vessels. Ten vascular regions showed persistent abnormalities on resting SQ30217 scans; eight of these were distal to stenoses of at least 90% and three were also abnormal on thallium redistribution images. Hepatic uptake of SQ30217 obscured inferoapical segments in some views in 14/20 patients but did not interfere with abnormal vessel identification.

  7. SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: A meta analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tao; Yang, Lin-feng [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Zhai, Ji-liang [Department of Medical Imaging, The Branch of TaiAn Central Hospital, Middle of Changcheng Road, Shandong Province, China. 271000 (China); Li, Jiang [Department of Medical Imaging, Affiliated Hospital of Taishan Medical University, No, 706, Taishan Road, Shandong Province, China. 271000 (China); Wang, Qi-meng [Department of Medical Imaging, Taishan Hospital of Traditional Chinese Medicine, No, 216, Yingxuan Street, Shandong Province, China. 271000. (China); Zhang, Rui-jie; Wang, Sen; Peng, Zhao-hui [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Li, Min, E-mail: liminyingxiang@163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China)

    2014-06-15

    Purpose: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. Methods: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. Results: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P = 0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70–83%) and 77% (95%CI, 67–84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57–74%) and specificity was 81% (95%CI, 70–89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. Conclusions: The accuracy between FFR and MPS SPECT was moderate.

  8. An observer study methodology for evaluating detection of motion abnormalities in gated myocardial perfusion SPECT.

    Science.gov (United States)

    Lalush, David S; Jatko, Megan K; Segars, W Paul

    2005-03-01

    To address the task of detecting nonischemic motion abnormalities from animated displays of gated myocardial perfusion single photon emission computed tomography data, we performed an observer study to evaluate the difference in detection performance between gating to 8 and 16 frames. Images were created from the NCAT mathematical phantom with a realistic heart simulating hypokinetic motion in the left lateral wall. Realistic noise-free projection data were simulated for both normal and defective hearts to obtain 16 frames for the cardiac cycle. Poisson noise was then simulated for each frame to create 50 realizations of each heart, All datasets were processed in two ways: reconstructed as a 16-frame set, and collapsed to 8 frames and reconstructed. Ten observers viewed the cardiac images animated with a realistic real-time frame rate. Observers trained on 100 images and tested on 100 images, rating their confidence on the presence of a motion defect on a continuous scale. None of the observers showed a significant difference in performance between the two gating methods. The 95% confidence interval on the difference in areas under the ROC curve (Az8 - Az16) was -0.029-0.085. Our test did not find a significant difference in detection performance between 8-frame gating and 16-frame gating. We conclude that, for the task of detecting abnormal motion, increasing the number of gated frames from 8 to 16 offers no apparent advantage.

  9. Myocardial perfusion SPECT in stable angina;Place de la scintigraphie myocardique dans l'angor stable

    Energy Technology Data Exchange (ETDEWEB)

    Jau, P.; Jacob, T. [HP Clairval, Service de medecine nucleaire, 13 - Marseille (France); Lecorff, G.; Bouvier, J.L.; Novella, P.; Bechet, V.; Pelet, V. [HP Clairval, Service de cardiologie, 13 - Marseille (France)

    2010-03-15

    We study the precise contribution of myocardial scintigraphy in the therapeutic management of stable coronary artery disease. Until recently, treatment was focused on revascularization, often by coronary angioplasty.Recent studies have challenged this practice by showing the absence of superiority of angioplasty compared to optimal medical therapy.The problem now is to define for each stable coronary artery disease, and individually, the best of both treatment options. In this spirit, the functional approach to coronary artery disease by myocardial perfusion scintigraphy is most interesting.The diagnostic performance, including sensitivity and negative predictive value, and the prognostic value of the technique are clearly established. Recent studies show that a therapeutic decision based on a functional approach to the patient is valid.We need to know this development in cardiology for best position in the multidisciplinary discussions, myocardial scintigraphy as a functional approach to stable coronary artery disease. (N.C.)

  10. Value of cardiac 320-multidetector computed tomography and cardiac magnetic resonance imaging for assessment of myocardial perfusion defects in patients with known chronic ischemic heart disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Kühl, Jørgen T; Mathiasen, Anders B;

    2013-01-01

    the modified 17-segment American Heart Association model. For the qualitative analysis, each segment was graded according to the following scoring system: 0 = no defect, 1 = hypoperfusion transmural extent 1/2, and 4 = infarct stigmata. In the semiquantitative analysis the perfusion was either scored 0 (normal...... and CMR images. The qualitative and semiquantitative MDCT against CMR analysis of rest and stress images showed high concordance to detect perfusion defects per vascular territory and on a per myocardial segment basis. 320-MDCT and CMR perfusion imaging can be used clinically to identify myocardial...

  11. Computational Fluid Dynamics Simulations of Contrast Agent Bolus Dispersion in a Coronary Bifurcation: Impact on MRI-Based Quantification of Myocardial Perfusion

    OpenAIRE

    Regine Schmidt; Dirk Graafen; Stefan Weber; Schreiber, Laura M.

    2013-01-01

    Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between the LV and the myocardial tissue. Negligence of bolus dispersion could cause an error in MBF determin...

  12. Association of serum cystatin C levels with myocardial perfusion and cardiac functional recovery in patients with anterior wall ST elevation myocardial infarction treated with primary coronary intervention.

    Science.gov (United States)

    Tang, Liang; Fang, Zhen-Fei; Zhou, Sheng-Hua; Tai, Shi; Ahmed, Salah; Huang, Feng; Shen, Xiang-Qian; Zhao, Yan-Shu; Hu, Xin-Qun

    2016-09-01

    This study sought to investigate the association of baseline serum cystatin C levels with myocardial perfusion and cardiac functional recovery in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). 108 patients with a first anterior STEMI who underwent PPCI were enrolled. Serum cystatin C was measured by immunoturbidimetric method. Patients were divided into two groups according to the median cystatin C levels on admission: group 1 (≥median, n = 54) and group 2 (C levels on admission. Patients with an IMR ≥33.7 U also had significantly higher cystatin C levels. The WMSI showed a greater improvement in group 2 than in group 1 and there was a significant negative correlation between improvement of WMSI and the cystatin C levels. There was no significant difference in MACEs between the 2 groups. However, congestive heart failure (CHF) was observed significantly more frequent in group 1 than in group 2 (18.5 vs. 5.6 %, p = 0.022). Multivariate logistic regression analysis demonstrated that cystatin C levels at admission were a significant independent predictor of angiographic no-reflow and the development of CHF at 6-month follow-up. Elevated cystatin C levels at admission were independently associated with impaired myocardial perfusion, poor cardiac functional recovery and development of CHF in patients with anterior STEMI undergoing PPCI.

  13. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  14. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  15. Acute chest pain in emergency room. Preliminary findings with 40-64-slice CT ECG-gated of the whole chest.

    Science.gov (United States)

    Coche, E

    2007-01-01

    ECG-gated MDCT of the entire chest represents the latest technical advance in the diagnostic work-up of atypical chest pain. The authors report their preliminary experience with the use of 40 and 64-slice CT in the emergency room and recommend to study only patients with moderate likelihood of coronary artery disease. ECG-gated MDCT of the entire chest will be preferentially performed on 64-slice MDCT rather than 40-slice MDCT because it enable to reduce the scan time (18 seconds versus 28 seconds acquisition time), the volume of contrast medium (82 mL + 15 mL versus 97 mL + 15 mL of highly concentrated contrast agent for a patient of 70 kgs) and radiation exposure (17 mSv versus 19 mSv). Approximately 1500 to 2000 of images are produced and need to be analysed on a dedicated workstation by a radiologist expert in cardiac and thoracic disorders. At the present time, only a few studies exist in the literature showing some promising results but further large clinical studies are needed before to implement such sophisticated protocol in emergency room.

  16. Diagnosis of coronary artery disease using myocardial perfusion SPECT in patients with diabetes mellitus: analysis of risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Hyoung; Kang, Seong Min; Bae, Jin Ho; Jeong, Shin Young; Lee, Sang Woo; Yoo, Jeong Soo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University, Daegu, (Korea, Republic of)

    2006-06-15

    Diabetes mellitus is a critical disease with higher rates of cardiovascular morbidity and mortality due to myocardial ischemia and infarction. There is growing interest in how to determine high-risk patients who are candidates for screening testing. This study was performed to evaluate the incidence of coronary artery disease (CAD) in diabetic patients detected by Tc-99m MIBI myocardial perfusion SPECT (MPS) and to assess risk factors of CAD and cardiac hard events. 203 diabetic patients (64 male, mean age 64.1 {+-} 9.0 years) who underwent MPS were included between Jan 2000 and July 2004. Cardiac death and nonfatal myocardial infarction (MI) were considered as hard events, and coronary angioplasty and bypass surgery >60 days after testing were considered as soft events. The mean follow-up period was 36 {+-} 18 months. Patients underwent exercise (n=6) or adenosine stress (n=197) myocardial perfusion SPECT. Perfusion defects on MPS were detected in 28.6% (58/203) of the patients. There was no cardiac death but 11 hard events were observed. The annual cardiac hard event rate was 1.1%. In univariate analysis of clinical factors, typical anginal pain, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were significantly associated with the occurrence of hard events. Anginal pain, peripheral vascular disease, and resting ECG abnormality remained independent predictors of nonfatal MIs with multivariate analysis. Abnormal SPECT results were significantly associated with high prevalence of hard events but not independent predictors on uni- and multivariate analyses. patients who were male, had longer diabetes duration (especially over 20 years), peripheral vascular disease, peripheral polyneuropathy, or resting ECG abnormality had higher incidence of CAD. Among clinical factors in diabetic patients, typical angina, peripheral vascular disease, peripheral polyneuropathy, and resting ECG abnormality were strong predictors of hard events.

  17. Costs and clinical outcomes after coronary multidetector CT angiography in patients without known coronary artery disease: comparison to myocardial perfusion SPECT.

    Science.gov (United States)

    Min, James K; Kang, Ning; Shaw, Leslee J; Devereux, Richard B; Robinson, Matthew; Lin, Fay; Legorreta, Antonio P; Gilmore, Amanda

    2008-10-01

    To assess costs and clinical outcomes in individuals without known coronary artery disease (CAD) who underwent multidetector computed tomographic (CT) angiography compared with those in matched patients who underwent myocardial perfusion single photon emission computed tomography (SPECT). Data were captured from a deidentified, HIPAA-compliant data warehouse. We examined 1-year CAD costs (additional diagnostic coronary testing, CAD hospitalization, and coronary procedural and revascularization costs) and clinical outcomes in individuals without known CAD who underwent multidetector CT (n = 1647) compared with those in a matched cohort of patients who underwent myocardial perfusion SPECT (n = 6588). Cox proportional hazards models were employed for clinical outcome measures, including CAD hospitalization, myocardial infarction, and angina. Adjusted CAD costs in the multidetector CT group were 25.9% lower than in the myocardial perfusion SPECT group, by an average of $1075 (95% confidence interval [CI]: $243, $2570) per patient. Those in the multidetector CT group were more likely to undergo downstream testing with myocardial perfusion SPECT (odds ratio, 6.65; 95% CI: 5.05, 8.75; P < .001), while those in the myocardial perfusion SPECT group were more likely to undergo downstream testing with invasive angiography (odds ratio, 6.25; 95% CI: 4.35, 9.09; P < .001). The multidetector CT group was less likely to undergo coronary revascularization (hazard ratio, 0.76; 95% CI: 0.75, 0.77; P < .001) than the myocardial perfusion SPECT group. There was no significant difference between multidetector CT and myocardial perfusion SPECT groups for rates of myocardial infarction (0.4% for both) or CAD hospitalization (0.7% vs 1.1%, respectively), while rates of angina were significantly lower in the multidetector CT group (4.3% vs 6.4%, P < .001). Individuals without known CAD who underwent multidetector CT as an initial diagnostic test, compared with those who underwent

  18. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  19. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT

    Science.gov (United States)

    Ghaly, Michael; Links, Jonathan M.; Frey, Eric C.

    2015-07-01

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6-5 and acquisition energy window widths of 16-22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16-22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results

  20. Effect of Chinese Drugs for Supplementing Qi, Nourishing Yin and Activating Blood Circulation on Myocardial Perfusion in Patients with Acute Myocardial Infarction after Revascularization

    Institute of Scientific and Technical Information of China (English)

    LI Yong-qiang; JIN Mei; QIU Sheng-lei; WANG Pei-li; ZHU Tian-gang; WANG Cheng-long; LI Tian-chang; LIU Hong-xu; BIAN Hong; YAO Li-fang; SHI Da-zhuo

    2009-01-01

    Objective: To observe the effects of Chinese drugs for supplementing qi, nourishing yin and activating blood circulation on the myocardial perfusion in acute myocardial infarction (AMI) patients after revascularization. Methods: Eighty patients with anterior or inferior ventricular wall AMI, who had received revascularization by intravenous thrombolysis or coronary bypass, were randomized into the treated group and the control group equally, both treated with conventional Western medical treatment, but combined, respectively, Dobutamine stress echocardiography (DSE) was performed 14 days and 3 months after revascularization, respectively on every patient to observe blood perfusion extent (b value), myocardial perfusion velocity (k value) and local blood flow volume (k × b) in left ventricular infarction-related vascular segments under stressed state. Results: With 5 cases dropping out in the observation pedod (3 in the treated group and 2 in the control group), the tdal was completed in 75 patients in total. The 14-day DSE shows that the b value and k×b value of left anterior ventricular wall mid segment and apex segment, and the k value of apex segment in patients with antedor wall AMI, as well as the b value and k×b of basel segment in patients with infedor wall AMI in the treated group were significantly higher than those in the control group (P<0.05 or P<0.01). The 3-month DSE shows that the b value of apex segment, k×b value of basal segment, mid segment and apex segment of left anterior ventdcular wall in patients with anterior wall AMI as well as the b value and k x b value of basal segment of left infedor ventricular wall in patients with inferior wall AMI were all higher in the treated group than those in the control group, respectively (P<0.05). The comparison between 14-day DSE and 3-month DSE in the treated group showed that the b value of apex segment of left antedor ventdcular wall in patients with antedor wall AMI and the k×b value of apex

  1. MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AUTOPERFUSION AND FORCED PERFUSION - AN IN-VITRO COMPARISON

    NARCIS (Netherlands)

    DEMUINCK, ED; VERKERKE, BJ; RAKHORST, G; LIE, KI

    1994-01-01

    During coronary angioplasty, perfusion distal to the inflated angioplasty balloon can be maintained with autoperfusion balloon catheters and coronary perfusion pumps. The blood flow rates through the autoperfusion balloon catheters and the flow rates achieved with a perfusion pump were compared in v

  2. Prognosis of patients with positive exercise test and normal myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Ahn, B. C.; Lee, J.; Lee, K. B [College of Medicine, Kyungpook National University, Daegu (Korea, Republic of)

    2004-07-01

    Exercise SPECT myocardial perfusion imaging(Ex-MPI) is regarded as a predictive technique particularly in patients with coronary artery disease(CAD) capable of performing exercise testing. In clinical practice, we encounter equivocal situations of discordant findings between exercise ECG and MPI. We evaluated the prognosis of subjects with positive ECG and normal MPI findings, and predictive factors for cardiac events. 2571 Ex-MPI studies were reviewed over a period of 3 years. Subjects were followed for more than 2 years(24-56 months, mean 35{+-}10months) for cardiac events after study. The cardiac events were defined as hard events(cardiac death and nonfatal myocardial infarction(MI)) and soft events(aggravation of CAD necessitating revascularization, congestive heart failure necessitating hospital admission). We evaluated age, sex, typical angina pain, rest ECG, hypertension, diabetes mellitus(DM), serum levels of cholesterol and LDL, smoking history, history of cerebrovascular disease(CVD) and peripheral artery disease(PAD), and rest left ventricular ejection fraction(LVEF) as clinical variables. Of 83 subjects with positive ECG and normal MPS findings, 6 were considered as false negative results confirmed with coronary angiography. There were 77 patients (mean age 52{+-}10 years, 39 males) with positive ECG and normal MPI results. During the follow-up period, of 77 there were 3 cardiac events (annual rate 1.9%), no cardiac death, 2 nonfatal MIs (annual rate 1.3%) and 1 soft event (annual rate 0.6%). 2/39 males(5.1%), and 1/38 females(2.6%) had cardiac events. All cardiac events were observed within 2 years. 1-year cardiac event rate was 0.6% and 2-year cardiac event rate was 1.9%. Among clinical factors, male sex, typical chest pain and smoking history at the time of MPI were predictive of cardiac events. Patients with positive ECG and negative EX-MPI results have low risk for cardiac events. Nevertheless, the cardiac events cannot be excluded totally in some

  3. Myocardial perfusion SPECT identifies patients with left bundle branch block patterns at high risk for future coronary events.

    Science.gov (United States)

    ten Cate, Tim J F; Kelder, Johannes C; Plokker, Herbert W M; Verzijlbergen, J Fred; van Hemel, Norbert M

    2010-04-01

    The value of myocardial perfusion SPECT (MPS) for patients with left bundle branch block (LBBB) or right ventricular apical (RVA) pacing seems reduced. The prognosis of patients with only abnormal activation related perfusion defects (AARD) due to LBBB or RVA-pacing is similar to those with a normal MPS. We assessed the prognostic value of MPS in patients with LBBB or RVA pacing. Patients with LBBB or RVA pacing referred for vasodilator stress MPS between April 2002 and January 2006 were analyzed. Group 1 are patients with normal MPS and MPS with AARD. Group 2 are patients with an MPS with a perfusion defect extending outside the AARD area. Events were cardiac death, acute myocardial infarction and coronary revascularization. In Group 1 (101 patients) 12 events and in Group 2 (96 patients) 45 events occurred during a mean follow-up of 2.6 +/- 1.5 years. The prognosis of Group 2 was significantly worse (49%) compared with Group 1 (91%). The annual cardiac death rate was 0.7%/year in Group 1 and 6.4%/year in Group 2 (P < .001). The prognosis of patients with LBBB was not different from those with RVA pacing. Group 2 had a significantly worse cardiac prognosis compared to Group 1. The annual cardiac death rate of <1% in Group 1 warrants a watchful waiting strategy, whereas the cardiac death rate in Group 2 warrants aggressive invasive coronary strategies.

  4. Non-uniform noise spatial distribution in CT myocardial perfusion and a potential solution: statistical image reconstruction

    Science.gov (United States)

    Thériault Lauzier, Pascal; Tang, Jie; Chen, Guang-Hong

    2012-03-01

    Myocardial perfusion scans are an important tool in the assessment of myocardial viability following an infarction. Cardiac perfusion analysis using CT datasets is limited by the presence of so-called partial scan artifacts. These artifacts are due to variations in beam hardening and scatter between different short-scan angular ranges. In this research, another angular range dependent effect is investigated: non-uniform noise spatial distribution. Images reconstructed using filtered backprojection (FBP) are subject to this effect. Statistical image reconstruction (SIR) is proposed as a potential solution. A numerical phantom with added Poisson noise was simulated and two swines were scanned in vivo to study the effect of FBP and SIR on the spatial uniformity of the noise distribution. It was demonstrated that images reconstructed using FBP often show variations in noise on the order of 50% between different time frames. This variation is mitigated to about 10% using SIR. The noise level is also reduced by a factor of 2 in SIR images. Finally, it is demonstrated that the measurement of quantitative perfusion metrics are generally more accurate when SIR is used instead of FBP.

  5. Myocardial perfusion scintigraphy 2008 in Germany. Results of the fourth query; Myokard-Perfusions-Szintigraphie 2008 in Deutschland. Ergebnisse der vierten Erhebung

    Energy Technology Data Exchange (ETDEWEB)

    Lindner, O. [Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany). Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung; Burchert, W. [Herz- und Diabeteszentrum NRW, Bad Oeynhausen (Germany). Inst. fuer Radiologie, Nuklearmedizin und Molekulare Bildgebung; Deutsche Gesellschaft fuer Nuklearmedizin (Germany). Arbeitsgemeinschaft ' Kardiovaskulaere Nuklearmedizin' ; Bengel, F.M. [Johns Hopkins Medical Institutions, Baltimore (United States). Cardiovascular Nuclear Medicine; Deutsche Gesellschaft fuer Nuklearmedizin (Germany). Arbeitsgruppe ' Nuklearkardiologische Diagnostik' ; Zimmermann, R. [Deutsche Gesellschaft fuer Nuklearmedizin (Germany). Arbeitsgruppe ' Nuklearkardiologische Diagnostik' ; Klinikum Pforzheim GmbH, Pforzheim (Germany). Medizinische Klinik; Dahl, J. vom [Kliniken Maria Hilf GmbH, Moenchengladbach (Germany). Klinik fuer Kardiologie; Schaefer, W. [Kliniken Maria Hilf GmbH, Moenchengladbach (Germany). Klinik fuer Nuklearmedizin; Schober, O. [Muenster Univ. (Germany). Inst. of Molecular Imaging; Schaefers, M. [Deutsche Gesellschaft fuer Nuklearmedizin (Germany). Arbeitsgemeinschaft ' Kardiovaskulaere Nuklearmedizin' ; Muenster Univ. (Germany). Inst. of Molecular Imaging

    2010-07-01

    Aim: The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine in cooperation with the working group Nuclear Cardiology of the German Cardiac Society herewith present the results of the 4{sup th} survey on myocardial perfusion scintigraphy (MPS) of the year 2008. Method: 310 questionnaires (191 private practices (PP), 93 hospitals (HO), 31 university hospitals (UH)) were evaluated. Results: MPS of 98 947 patients were reported. 15% of them were younger than 50 y, 57% between 50 and 70 y and 28% older than 70 y. 88% [2007: 83%] of all were studied with Tc-99m perfusion tracers. The patient radiation exposure of a stress and rest protocol considering German standard recommended doses was 8.5 mSv, of a stress-only protocol 1.9 mSv. 77% [2007: 76%] of the MPS were performed in PP, 15% [2007: 15%] in HO and 8% [2007: 9%] in UH. From 2005 to 2008 there was a mild increase in the MPS numbers by 1.2% (PP +7.1%, HO -5.5%, UH -31.4%). The type of stress was pharmacological in 30% [2007: 27%]; 68% adenosine (of these 22% with exercise), 29% dipyridamole (of these 64% with exercise), and <1% dobutamine. Gated SPECT was performed in 46% [2007: 47%] of all rest and in 42% [2007: 44%] of all stress MPS. 62% [2007: 61%] of all institutions did not use perfusion scores. Conclusion: The MPS numbers from 2005 to 2008 in Germany can be regarded as stable. However, there are considerable shifts from HO and UH to PP. The well known potential of MPS considering risk stratification and functional analysis has not been tapped so far. Both gated SPECT and a quantitative perfusion analysis should be performed routinely in every patient.

  6. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Boogers, Mark J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); The Interuniversity Cardiology Institute of the Netherlands, Utrecht (Netherlands); Chen, Ji; Garcia, Ernest V. [Emory University School of Medicine, Department of Radiology, Atlanta, GA (United States); Bommel, Rutger J. van; Borleffs, C.J.W.; Schalij, Martin J.; Wall, Ernst E. van der; Bax, Jeroen J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Dibbets-Schneider, Petra; Hiel, Bernies van der; Younis, Imad Al [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands)

    2011-02-15

    The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of {>=}15% in LVESV. Enrolled in the study were 90 patients (72% men, 67{+-}10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements. (orig.)

  7. Cardiovascular mortality prediction in veterans with arm exercise vs pharmacologic myocardial perfusion imaging.

    Science.gov (United States)

    Martin, Wade H; Xian, Hong; Chandiramani, Pooja; Bainter, Emily; Klein, Andrew J P

    2015-08-01

    No data exist comparing outcome prediction from arm exercise vs pharmacologic myocardial perfusion imaging (MPI) stress test variables in patients unable to perform treadmill exercise. In this retrospective study, 2,173 consecutive lower extremity disabled veterans aged 65.4 ± 11.0years (mean ± SD) underwent either pharmacologic MPI (1730 patients) or arm exercise stress tests (443 patients) with MPI (n = 253) or electrocardiography alone (n = 190) between 1997 and 2002. Cox multivariate regression models and reclassification analysis by integrated discrimination improvement (IDI) were used to characterize stress test and MPI predictors of cardiovascular mortality at ≥10-year follow-up after inclusion of significant demographic, clinical, and other variables. Cardiovascular death occurred in 561 pharmacologic MPI and 102 arm exercise participants. Multivariate-adjusted cardiovascular mortality was predicted by arm exercise resting metabolic equivalents (hazard ratio [HR] 0.52, 95% CI 0.39-0.69, P heart rate recovery (HR 0.61, 95% CI 0.44-0.86, P exercise delta (peak-rest) heart rate (both P exercise MPI prognosticated cardiovascular death by multivariate Cox analysis (HR 1.98, 95% CI 1.04-3.77, P exercise MPI defect number, type, and size provided IDI over covariates for prediction of cardiovascular mortality (IDI = 0.074-0.097). Only pharmacologic defect size prognosticated cardiovascular mortality (IDI = 0.022). Arm exercise capacity, heart rate recovery, and pharmacologic and arm exercise heart rate responses are robust predictors of cardiovascular mortality. Arm exercise MPI results are equivalent and possibly superior to pharmacologic MPI for cardiovascular mortality prediction in patients unable to perform treadmill exercise. Published by Elsevier Inc.

  8. New reconstruction algorithm allows shortened acquisition time for myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Valenta, Ines; Treyer, Valerie; Husmann, Lars; Gaemperli, Oliver; Schindler, Michael J.; Herzog, Bernhard A.; Veit-Heibach, Patrick; Pazhenkottil, Aju P.; Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology, Zurich (Switzerland); Buechel, Ronny R.; Nkoulou, Rene [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland)

    2010-04-15

    Shortening scan time and/or reducing radiation dose at maintained image quality are the main issues of the current research in radionuclide myocardial perfusion imaging (MPI). We aimed to validate a new iterative reconstruction (IR) algorithm for SPECT MPI allowing shortened acquisition time (HALF time) while maintaining image quality vs. standard full time acquisition (FULL time). In this study, 50 patients, referred for evaluation of known or suspected coronary artery disease by SPECT MPI using 99mTc-Tetrofosmin, underwent 1-day adenosine stress 300 MBq/rest 900 MBq protocol with standard (stress 15 min/rest 15 min FULL time) immediately followed by short emission scan (stress 9 min/rest 7 min HALF time) on a Ventri SPECT camera (GE Healthcare). FULL time scans were processed with IR, short scans were additionally processed with a recently developed software algorithm for HALF time emission scans. All reconstructions were subsequently analyzed using commercially available software (QPS/QGS, Cedars Medical Sinai) with/without X-ray based attenuation correction (AC). Uptake values (percent of maximum) were compared by regression and Bland-Altman (BA) analysis in a 20-segment model. HALF scans yielded a 96% readout and 100% clinical diagnosis concordance compared to FULL. Correlation for uptake in each segment (n = 1,000) was r = 0.87at stress (p < 0.001) and r = 0.89 at rest (p < 0.001) with respective BA limits of agreement of -11% to 10% and -12% to 11%. After AC similar correlation (r = 0.82, rest; r = 0.80, stress, both p < 0.001) and BA limits were found (-12% to 10%; -13% to 12%). With the new IR algorithm, SPECT MPI can be acquired at half of the scan time without compromising image quality, resulting in an excellent agreement with FULL time scans regarding to uptake and clinical conclusion. (orig.)

  9. Chest Pain with Normal Thallium-201 Myocardial Perfusion Image – Is It Really Normal?

    Science.gov (United States)

    Liu, Pang-Yen; Lin, Wen-Yu; Lin, Li-Fan; Lin, Chin-Sheng; Lin, Wei-Shiang; Cheng, Shu-Meng; Yang, Shih-Ping; Liou, Jun-Ting

    2016-01-01

    Background Thallium-201 myocardial perfusion image (MPI) is commonly used to detect coronary artery disease in patients with chest pain. Although a normal thallium-201 MPI result is generally considered to be a good prognosis and further coronary angiogram is not recommended, there are still a few patients who suffer from unexpected acute coronary events. The aim of this study was to investigate the clinical prognosis in patients with normal thallium-201 MPI. Methods From January 2006 to August 2012, a total 22,003 patients undergoing thallium-201 MPI in one tertiary center were screened. Of these, 8092 patients had normal results and were investigated retrospectively. During follow-up, 54 patients underwent coronary angiogram because of refractory typical angina pectoris or unexpected acute coronary events. These 54 patients were divided into 2 groups: group I consisted of 26 (48.1%) patients with angiography-proven significant coronary artery stenosis, and group II consisted of 28 (51.9%) patients without significant stenosis. Results Patients in group I had a higher prevalence of prior coronary stenting and electrocardiographic features of ST depression compared with patients in group II. The multivariate analysis demonstrated that both prior coronary stenting and ST depression were risk predictors of unexpected acute coronary events in the patients with normal thallium-201 MPI [odds ratio (OR), 5.93; 95% confidence interval (CI): 1.03-34.06, p = 0.05 and OR, 7.10; 95% CI: 1.28-39.51, p = 0.03,respectively]. Conclusions Although there is a low incidence of unexpected acute coronary events in patients with chest pain and normal thallium-201 MPI, physicians should be aware of the potentials risk in certain patients in this specific population. PMID:27274174

  10. Radio-adaptive Response in Myocardial Perfusion Imaging Induced by Technetium-99m

    Science.gov (United States)

    Shirazi, Mohammad Mehdi; Shabestani-Monfared, Ali; Shahidi, Maryam; Amiri, Mehrangiz; Abedi, Seyed Mohammad; Borzoueisileh, Sajad; Gorji, Kourosh Ebrahim Nejad

    2017-01-01

    Purpose of the Study: Low dose radiation will induce adaptation and following exposure to an adaptive dose, the cells are more resistance to following challenging doses. This phenomenon is known as radio-adaptive response. The aim of this study was to investigate the percentage of apoptotic cells in the peripheral blood samples of the patients which undergo myocardial perfusion imaging (MPI) with technetium-99m (Tc-99m) before thallium scan to assess the induction of radio-adaptive response. Materials and Methods: In this study, 97 samples from 74 patients, referred to nuclear medicine center of Mazandaran Heart Hospital for MPI, which had no history of diagnostic, therapeutic, occupational, and radioactive exposures during past 2 years, were provided. The participants were classified into four groups including control, patients which were scanned solely with technetium, the patients which examined by thallium and the last group were the patients that examined by technetium followed by thallium. Then 2 ml Peripheral blood samples were obtained, and after 24 h incubating, the samples were studied by neutral comet assay. Statistical analysis was carried out using Student's t-test along with one-way analysis of variance. Results: The mean percentage of apoptotic cells in the exposed groups were higher than the control. Furthermore, among exposed groups, the apoptotic cells in thallium group were more than others and this index was significantly lower in the group which was undergone technetium administration before thallium scan. Conclusions: These findings suggest that exposure to Tc-99m could induce a radio-adaptive response against the exposure of thallium-201.

  11. Design of a digital phantom population for myocardial perfusion SPECT imaging research

    Science.gov (United States)

    Ghaly, Michael; Du, Yong; Fung, George S. K.; Tsui, Benjamin M. W.; Links, Jonathan M.; Frey, Eric

    2014-06-01

    Digital phantoms and Monte Carlo (MC) simulations have become important tools for optimizing and evaluating instrumentation, acquisition and processing methods for myocardial perfusion SPECT (MPS). In this work, we designed a new adult digital phantom population and generated corresponding Tc-99m and Tl-201 projections for use in MPS research. The population is based on the three-dimensional XCAT phantom with organ parameters sampled from the Emory PET Torso Model Database. Phantoms included three variations each in body size, heart size, and subcutaneous adipose tissue level, for a total of 27 phantoms of each gender. The SimSET MC code and angular response functions were used to model interactions in the body and the collimator-detector system, respectively. We divided each phantom into seven organs, each simulated separately, allowing use of post-simulation summing to efficiently model uptake variations. Also, we adapted and used a criterion based on the relative Poisson effective count level to determine the required number of simulated photons for each simulated organ. This technique provided a quantitative estimate of the true noise in the simulated projection data, including residual MC simulation noise. Projections were generated in 1 keV wide energy windows from 48-184 keV assuming perfect energy resolution to permit study of the effects of window width, energy resolution, and crosstalk in the context of dual isotope MPS. We have developed a comprehensive method for efficiently simulating realistic projections for a realistic population of phantoms in the context of MPS imaging. The new phantom population and realistic database of simulated projections will be useful in performing mathematical and human observer studies to evaluate various acquisition and processing methods such as optimizing the energy window width, investigating the effect of energy resolution on image quality and evaluating compensation methods for degrading factors such as crosstalk in

  12. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  13. Prevalence of Ischemia on Myocardial Perfusion Scintigraphy of Pre- and Postmenopausal Women

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Daniel Augusto Message dos, E-mail: danielmessage@cardiol.br; Navarro, Wendy Yasdin Sierraalta; Alexandre, Leonardo Machado; Cestari, Priscila Feitosa; Smanio, Paola Emanuela Poggio [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP (Brazil)

    2013-12-15

    In postmenopausal women, the presence of risk factors for coronary artery disease (CAD) increases. However, the difference in prevalence of ischemia between pre- and postmenopausal women with multiple risk factors for CAD has not been well established. To compare the prevalence of ischemia on Tc{sup 99m}-sestamibi myocardial perfusion scintigraphy (MPS) in pre-and postmenopausal women, and to evaluate whether menopause can be considered an independent risk predictor of ischemia in women with multiple risk factors for CAD. This study retrospectively assessed 500 MPS of pre- and postmenopausal women with multiple risk factors for CAD. Statistical analysis was performed by using Fisher exact test and univariate and multivariate analysis, a p value ≤ 0.05 being considered significant. Postmenopausal women represented 55.9% of the sample; 83.3% were hypertensive; 28.9%, diabetic; 32.1%, smokers; 25%, obese; 61.2% had high cholesterol levels; and 34.3% had known CAD. Postmenopausal women were more often hypertensive, diabetic and dyslipidemic, and had lower functional capacity on exercise testing (p = < 0.005). The presence of ischemia on MPS did not significantly differ between the pre- and postmenopausal groups (p = 0.395). The only variable associated with ischemia on MPS was known CAD (p = 0.004). The results suggest that, in women with multiple risk factors for CAD, menopause was not an independent predictor of ischemia on MPS. Those data support the idea that the investigation of ischemia via MPS in women with multiple risk factors for CAD should begin prior to menopause.

  14. Myocardial perfusion scintigraphy in identification and localization of individual coronary lesions

    Directory of Open Access Journals (Sweden)

    Baškot Branislav

    2004-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of myocardial perfusion scintigraphy with technetium-99m tetrofosmin by single-photon emission computed tomography (SPECT, using one-day protocol in the identification and localization of individual stenosed coronary vessels. Sixty-eight patients with suspected coronary artery disease (CAD were studied. In thirty of them coronary angiography showed significant stenosis (³50%. Nine patients were with one-vessel disease, 11 were with two-vessel disease, and 10 were with three-vessel disease. All the patients were administered two i.v. injections of 99mTc tetrofosmin, one at peak pharmacologic exercise (1-3 min after i.v. administration of dipiridamol 0.56 mg per kg during 4 min 370 MBq, and the other 740 MBq at rest 3 hrs after the exercise test (acquisition was obtained 15-30 min after injections for both studies. Overall sensitivity, specificity, and diagnostic accuracy in the identification of individual stenosed coronary vessels were 90%, 86%, and 88%, respectively. Sensitivity, specificity, and accuracy in each of the individual vascular territories were not significantly different: LAD (96% 64%, and 75%, ACx (73%, 100%, and 94%, RCA (95%, 93%, and 94%. The results of this study demonstrated one-day 99mTc-tetrofosmin SPECT scintigraphy to be suitable and accurate technique for the identification and localization of individual stenosed coronary vessels, as well as a highly sensitive method in the recognition of one- and multiple-vessel diseases of coronary arteries.

  15. Coronary flow reserve evaluated by {sup 201}Tl myocardial perfusion SPECT after coronary artery bypass grafting (CABG) for angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Ishino, Yoichi; Nakata, Hajime [Univ. of Occupational and Environmental Health, Kitakyusyu, Fukuoka (Japan)

    2000-11-01

    We compared the flow reserves of the coronary bypass vessels between arterial and venous grafts by {sup 201}Tl myocardial perfusion SPECT on the patients with angina pectoris who had no past history of myocardial infarction or intervention therapy such as PTCA. Thirty two patients had undergone a total of 70 bypass grafts and 66 of them were proved to be patent at postoperative CAG. Reversible defects were observed in 6 of 40 segments (15.0%) covered by patent venous grafts, and in 11 of 26 segments (42.3%) by patent arterial grafts. The rate of postoperative reversible defects was higher in the areas grafted by artery but this had no relation with the severity of coronary artery stenosis before CABG. This reversible defect is most likely to be caused by the character of artery graft itself and this should not be considered to highly suggest the restenosis or occlusion of the graft vessel. (author)

  16. Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Nylander Eva

    2008-03-01

    Full Text Available Abstract Background Myocardial perfusion imaging (MPI, using single photon emission computed tomography (SPECT is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease. Methods Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82, with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy. Results We found that coronary flow velocity reserve (CFVR determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes. Conclusion TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.

  17. Thrombus aspiration plus intra-infarct-related artery administration of tirofiban improves myocardial perfusion during primary angioplasty for acute myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    YAN Hong-bing; ZHANG Xiao-jiang; LI Wen-zheng; LI Shi-ying; SONG Li; WANG Jian; WU Zheng; CHI Yun-peng; ZHENG Bin; ZHAO Han-jun; LI Qing-xiang

    2010-01-01

    Background We developed a new combined strategy of thrombus aspiration plus intra-infarct-related artery (IRA) bolus administration of tirofiban via the aspiration catheter in patients with ST-segment elevation myocardial infarction (STEMI). This strategy can reduce the distal embolism and achieve highly localized concentrations of tirofiban, which can improve myocardial reperfusion without increasing the risk of bleeding. The aim of this study was to investigate whether this combined strategy is superior to thrombus aspiration alone in improving myocardial perfusion in patients with STEMI undergoing primary angioplasty.Results Baseline characteristics of the two groups were well-balanced. The TIMI 3 flow showed a better tendency in the intra-IRA group than in the aspiration alone group (97.22% vs. 87.04%, X~2=7.863, P=0.049). The peak of CK-MB (83.9 (68.9-310.5) U/L vs. 126.1 (74.7-356.7) U/L, P=0.034) and Tnl (42.7 (14.7-113.9) ng/ml vs. 72.5 (59.8-135.3) ng/ml, FMD.029) were lower in the intra-IRA group than in the aspiration alone group. LVEF in the hospital favored the intra-IRA group, (45.7±8.3)% to (42.9±12.1)%, t=1.98, P=0.049. There was a tendency towards a lower MACE at 9-month follow-up in the intra-IRA group although it did not reach statistical difference (Log-rank X~2=2.865, P=0.09). There was no statistical difference in any bleeding events between the two groups.Conclusions Thrombus aspiration plus intra-IRA bolus administration of tirofiban combined with angioplasty may be related with improved myocardium perfusion, saved more myocardium, and resulted in a better clinical prognosis.

  18. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, Abbas A., E-mail: abbas.ali.qayyum@regionh.dk [Department of Cardiology and Cardiac Catheterization Laboratory 2014, The Heart Centre, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Hasbak, Philip, E-mail: philip.hasbak@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Larsson, Henrik B.W., E-mail: henrik.larsson@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Functional Imaging Unit, Diagnostic Department, Glostrup Hospital, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Ndr. Ringvej 57, 2600 Copenhagen (Denmark); Christensen, Thomas E., E-mail: thomas.emil.christensen@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Ghotbi, Adam A., E-mail: adam.ali.ghotbi@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); Mathiasen, Anders B., E-mail: anders.b.mathiasen@gmail.com [Department of Cardiology and Cardiac Catheterization Laboratory 2014, The Heart Centre, Rigshospitalet, University Hospital of Copenhagen and Faculty of Health Sciences, Copenhagen University, Blegdamsvej 9, 2100 Copenhagen (Denmark); and others

    2014-07-15

    Introduction: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). Materials and methods: Fourteen patients with coronary artery stenosis underwent rest and adenosine stress imaging by 1.5-Tesla MR Scanner and a mCT/PET 64-slice Scanner. CMRI were analyzed based on Tikhonov's procedure of deconvolution without specifying an explicit compartment model using our own software. PET images were analyzed using standard clinical software. CMRI and PET data was compared with Spearman's rho and Bland–Altman analysis. Results: CMRI results were strongly and significantly correlated with PET results for the absolute global myocardial perfusion differences (r = 0.805, p = 0.001) and for global myocardial perfusion reserve (MPR) (r = 0.886, p < 0.001). At vessel territorial level, CMRI results were also significantly correlated with absolute PET myocardial perfusion differences (r = 0.737, p < 0.001) and MPR (r = 0.818, p < 0.001). Each vessel territory had similar strong correlation for absolute myocardial perfusion differences (right coronary artery (RCA): r = 0.787, p = 0.001; left anterior descending artery (LAD): r = 0.796, p = 0.001; left circumflex artery (LCX): r = 0.880, p < 0.001) and for MPR (RCA: r = 0.895, p < 0.001; LAD: r = 0.886, p < 0.001; LCX: r = 0.886, p < 0.001). Conclusion: On a global and vessel territorial basis, CMRI-measured absolute myocardial perfusion differences and MPR were strongly and significantly correlated with the Rb-82 PET findings.

  19. Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography.

    Science.gov (United States)

    Ikuye, Katharina; Buckert, Dominik; Schaaf, Lisa; Walcher, Thomas; Rottbauer, Wolfgang; Bernhardt, Peter

    2013-03-27

    Quantification of cardiovascular magnetic resonance (CMR) myocardial perfusion reserve (MPR) at 1.5 Tesla has been shown to correlate to invasive evaluation of coronary artery disease (CAD) and to yield good inter-observer agreement. However, little is known about quantitative adenosine-perfusion CMR at 3 Tesla and no data about inter-observer agreement is available. Aim of our study was to evaluate inter-observer agreement and to assess the diagnostic accuracy in comparison to quantitative coronary angiography (QCA). Fifty-three patients referred for coronary x-ray angiography were previously examined in a 3 Tesla whole-body scanner. Adenosine and rest perfusion CMR were acquired for the quantification of MPR in all segments. Two blinded and independent readers analyzed all images. QCA was performed in case of coronary stenosis. QCA data was used to assess diagnostic accuracy of the MPR measurements. Inter-observer agreement was high for all myocardial perfusion territories (ρ = 0.92 for LAD, ρ = 0.93 for CX and RCA perfused segments). Compared to QCA receiver-operating characteristics yielded an area under the curve of 0.78 and 0.73 for RCA, 0.66 and 0.69 for LAD, and 0.52 and 0.53 for LCX perfused territories. Inter-observer agreement of MPR quantification at 3 Tesla CMR is very high for all myocardial segments. Diagnostic accuracy in comparison to QCA yields good values for the RCA and LAD perfused territories, but moderate values for the posterior LCX perfused myocardial segments.

  20. Cell therapy in reperfused acute myocardial infarction does not improve the recovery of perfusion in the infarcted myocardium: a cardiac MR imaging study.

    Science.gov (United States)

    Robbers, Lourens F H J; Nijveldt, Robin; Beek, Aernout M; Hirsch, Alexander; van der Laan, Anja M; Delewi, Ronak; van der Vleuten, Pieter A; Tio, René A; Tijssen, Jan G P; Hofman, Mark B M; Piek, Jan J; Zijlstra, Felix; van Rossum, Albert C

    2014-07-01

    To investigate the effects of cell therapy on myocardial perfusion recovery after treatment of acute myocardial infarction (MI) with primary percutaneous coronary intervention (PCI). In this HEBE trial substudy, which was approved by the institutional review board (trial registry number ISRCTN95796863), the authors assessed the effects of intracoronary infusion with bone marrow-derived mononuclear cells (BMMCs) or peripheral blood-derived mononuclear cells (PBMCs) on myocardial perfusion recovery by using cardiac magnetic resonance (MR) imaging after revascularization. In 152 patients with acute MI treated with PCI, cardiac MR imaging was performed after obtaining informed consent-before randomization to BMMC, PBMC, or standard therapy (control group)-and repeated at 4-month follow-up. Cardiac MR imaging consisted of cine, rest first-pass perfusion, and late gadolinium enhancement imaging. Perfusion was evaluated semiquantitatively with signal intensity-time curves by calculating the relative upslope (percentage signal intensity change). The relative upslope was calculated for the MI core, adjacent border zone, and remote myocardium. Perfusion differences among treatment groups or between baseline and follow-up were assessed with the Wilcoxon signed rank or Mann-Whitney U test. At baseline, myocardial perfusion differed between the MI core (median, 6.0%; interquartile range [IQR], 4.1%-8.0%), border zone (median, 8.4%; IQR, 6.4%-10.2%), and remote myocardium (median, 12.2%; IQR, 10.5%-15.9%) (P < .001 for all), with equal distribution among treatment groups. These interregional differences persisted at follow-up (P < .001 for all). No difference in perfusion recovery was found between the three treatment groups for any region. After revascularization of ST-elevation MI, cell therapy does not augment the recovery of resting perfusion in either the MI core or border zone. © RSNA, 2014.

  1. Assessment of myocardial perfusion by positron emission tomography in patients with end-stage coronary artery disease treated with percutaneous myocardial revascularization

    Institute of Scientific and Technical Information of China (English)

    Marcus Wiemer; Johannes Peter Wielepp; Oliver Lindner; Wolfgang Burchert; Christoph Langer; Dieter Horstkotte; Thomas Butz

    2009-01-01

    Background Reportedly, patients with persistent refractory angina due to end-stage coronary artery disease (CAD) not amenable to traditional revascularization techniques have experienced symptomatic relief following laser revascularization, either surgical transmyocardial revascularization (TMR) or percutaneous myocardial revascularization (PMR). In spite of several hypotheses (i.e., channel patency, placebo effect, denervation, neoangiogenesis), the mechanism of action and the benefit remains controversial.Methods A prospective trial utilizing positron emission tomography (PET) was conducted as an attempt to correlate quantified myocardial blood flow (MBF) to clinical improvement following PMR. Thirteen consecutive patients with angina class >Ⅱ in spite of maximal medical treatment underwent PMR with a holmium:yttrium-aluminum-garnet (Ho:YAG) laser.MBF at rest and under hyperemia was assessed by [~(13)N]ammonia PET at baseline, 3 and 6 months following PMR.Results Mean angina class and exercise tolerance time improved at 6 months compared with baseline (P<0.001). The clinical results were accompanied with an improvement in hyperemic MBF (P=0.05) and a reduction in minimal coronary resistance (MCR; P<0.05) in PMR-treated segments. Opposite effects, reduced hyperemic MBF and increased MCR,were observed in nontreated segments. The increase in MCR in nontreated segments revealed the favorable therapeutic impact achieved in PMR-treated segments.Conclusion The results of this trial utilizing a quantitative technique to quantify myocardial perfusion link clinical improvement post-PMR to neoangiogenesis and consistently improved microcirculation.

  2. The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun Ah; Lee, Whal; Kang, Jin Hwa; Yin, Yong Hu; Chung, Jin Wook; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2009-06-15

    This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, signal-tonoise ratio [SNR] and contrast-to-noise ratio [CNR]) and the estimated radiation dose were calculated. As a preference test, two image readers were independently asked to choose one image from each pair of images. The results of both protocols were compared using the paired t-test or the Wilcoxon signed rank test. The 100-kVp images showed significantly more noise and a significantly higher vessel density than did the 120-kVp images. There were no significant differences in the SNR and CNR. The estimated reduction of the radiation dose for the 100-kVp protocol was 24%; 7.8 {+-} 0.4 mSV for 100-kVp and 10.1 {+-} 1.0 mSV for 120-kVp (p < 0.001). The readers preferred the 100-kVp images for reading (reader 1, p = 0.01; reader 2, p = 0.06), with their preferences being stronger when the subject's body mass index was less than 25. Reducing the tube kilovoltage from 120 to 100 kVp allows a significant reduction of the radiation dose without a significant change in the SNR and the CNR.

  3. Prospective versus retrospective ECG gating for dual source CT of the coronary stent: Comparison of image quality, accuracy, and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Lei, E-mail: zhaolei219@sohu.com [Beijing Anzhen Hospital of the Capital University of Medical Sciences (China); Zhang Zhaoqi; Fan Zhanming; Yang Lin; Du Jing [Beijing Anzhen Hospital of the Capital University of Medical Sciences (China)

    2011-03-15

    Objective: To compare image quality, diagnostic accuracy and radiation dose of prospective and retrospective electrocardiogram (ECG) gated dual source computed tomography (DSCT) for the evaluation of the coronary stent, using conventional coronary angiography (CA) as a standard reference. Design, setting and patients: Sixty patients (heart rates {<=}70 bpm) with previous stent implantation who were scheduled for CA were divided in two groups, receiving either prospective or retrospective ECG gated DSCT separately. Two reviewers scored coronary stent image quality and evaluated stent lumen. Results: There was no significant difference in image quality between the two groups. In the prospective group, there were 86.4% (51/59) stents with interpretable images, in the retrospective group, there were 87.5% (49/56) stents with interpretable images. Image quality was not influenced by age, body mass index or heart rate in either group, but heart rate variability had a weak impact on the image quality of the prospective group. Image noise was higher in the prospective group, but this difference reached statistical significance only by using a smooth kernel reconstruction. Per-stent based sensitivity, specificity, and positive and negative predictive value were 100%, 84.1%, 68.2%, and 100%, respectively, in the prospective CT angiography group and 94.4%, 86.8%, 77.3%, and 97.1%, respectively, in the retrospective CT angiography group. There was a significant difference in the effective radiation dose between the two groups, mean effective dose in the prospective and retrospective group was 2.2 {+-} 0.5 mSv (1.5-3.2 mSv) and 14.6 {+-} 3.3 mSv (10.0-20.4 mSv) (p < .001) respectively. Conclusions: Compared with retrospective CT angiography, prospective CT angiography has a similar performance in assessing coronary stent patency, but a lower effective dose in selected patients with regular heart rates {<=}70 bpm.

  4. Comparison of 128-Slice Low-Dose Prospective ECG-Gated CT Scanning and Trans-Thoracic Echocardiography for the Diagnosis of Complex Congenital Heart Disease

    Science.gov (United States)

    Bu, Guilin; Miao, Ying; Bin, Jingwen; Deng, Sheng; Liu, Taowen; Jiang, Hongchun; Chen, Weiping

    2016-01-01

    Objective To compare prospective ECG-gated multi-slice computed tomography (MSCT) and trans-thoracic echocardiography (TTE) in the diagnosis of complex congenital heart disease (CHD). Methods This was a prospective study of consecutive patients with complex CHD (age ECG-gated 128-slice spiral CT in the week before surgery. Effective radiation dose (ED) was calculated from volume CT dose index (CTDIvol) and dose length product (DLP). Image quality (5-point scale) was assessed independently by two radiologists. Using surgical findings as the reference, the diagnostic capabilities of MSCT and TTE were compared. Results Thirty-five patients (19 males) aged 1.59±1.58 years (range, 3 days to 74 months) were included. CTDIvol, DLP and ED were 0.90±0.24 mGy, 12.9±4.7 mGy∙cm and 0.64±0.21 mSv (range, 0.358–1.196 mSv), respectively. Image quality score was 4.3±0.5, and all images met the diagnostic requirements. The sensitivity, specificity, positive predictive value, and negative predictive value for diagnosing CHD were 97.2%, 99.8%, 99.0%, and 99.5%, respectively, for MSCT, and 90.6%, 99.8%, 99.0%, and 98.4%, respectively, for TTE. MSCT not only had a higher sensitivity than TTE overall (97.2% vs. 90.6%; PECG-gated CT scanning has important clinical value in the diagnosis of complex CHD in children, complementing and extending the findings of TTE. PMID:27788237

  5. Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Coche, Emmanuel; Goncette, Louis; Maldague, Baudouin [Universite Catholique de Louvain, Department of Medical Imaging, Cliniques Universitaires St-Luc, Brussels (Belgium); Vlassenbroek, Alain [Philips Medical Systems, Cleveland, OH (United States); Roelants, Veronique [Universite Catholique de Louvain, Department of Nuclear Medicine, Cliniques Universitaires St-Luc, Brussels (Belgium); D' Hoore, William [Catholic University of Louvain, Public Health, Brussels (Belgium); Verschuren, Franck [Universite Catholique de Louvain, Department of Emergency Medicine, Cliniques Universitaires St-Luc, Brussels (Belgium)

    2005-07-01

    This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65-99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16 x 1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland-Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5{+-}2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland-Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions. (orig.)

  6. Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

    Science.gov (United States)

    Coche, Emmanuel; Vlassenbroek, Alain; Roelants, Véronique; D'Hoore, William; Verschuren, Franck; Goncette, Louis; Maldague, Baudouin

    2005-07-01

    This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65-99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16x1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland-Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5+/-2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland-Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions.

  7. Comparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-04-01

    Myocardial blood flow (MBF) can be estimated from dynamic contrast enhanced (DCE) cardiac CT acquisitions, leading to quantitative assessment of regional perfusion. The need for low radiation dose and the lack of consensus on MBF estimation methods motivates this study to refine the selection of acquisition protocols and models for CT-derived MBF. DCE cardiac CT acquisitions were simulated for a range of flow states (MBF = 0.5, 1, 2, 3 ml (min g)-1, cardiac output = 3, 5, 8 L min-1). Patient kinetics were generated by a mathematical model of iodine exchange incorporating numerous physiological features including heterogenenous microvascular flow, permeability and capillary contrast gradients. CT acquisitions were simulated for multiple realizations of realistic x-ray flux levels. CT acquisitions that reduce radiation exposure were implemented by varying both temporal sampling (1, 2, and 3 s sampling intervals) and tube currents (140, 70, and 25 mAs). For all acquisitions, we compared three quantitative MBF estimation methods (two-compartment model, an axially-distributed model, and the adiabatic approximation to the tissue homogeneous model) and a qualitative slope-based method. In total, over 11 000 time attenuation curves were used to evaluate MBF estimation in multiple patient and imaging scenarios. After iodine-based beam hardening correction, the slope method consistently underestimated flow by on average 47.5% and the quantitative models provided estimates with less than 6.5% average bias and increasing variance with increasing dose reductions. The three quantitative models performed equally well, offering estimates with essentially identical root mean squared error (RMSE) for matched acquisitions. MBF estimates using the qualitative slope method were inferior in terms of bias and RMSE compared to the quantitative methods. MBF estimate error was equal at matched dose reductions for all quantitative methods and range of techniques evaluated. This suggests that

  8. An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yuan, E-mail: yuan.lin@duke.edu; Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, 2424 Erwin Road, Suite 302, Durham, North Carolina 27705 (United States)

    2014-02-15

    Purpose: In quantitative myocardial CT perfusion imaging, beam hardening effect due to dense bone and high concentration iodinated contrast agent can result in visible artifacts and inaccurate CT numbers. In this paper, an efficient polyenergetic Simultaneous Algebraic Reconstruction Technique (pSART) was presented to eliminate the beam hardening artifacts and to improve the CT quantitative imaging ability. Methods: Our algorithm made threea priori assumptions: (1) the human body is composed of several base materials (e.g., fat, breast, soft tissue, bone, and iodine); (2) images can be coarsely segmented to two types of regions, i.e., nonbone regions and noniodine regions; and (3) each voxel can be decomposed into a mixture of two most suitable base materials according to its attenuation value and its corresponding region type information. Based on the above assumptions, energy-independent accumulated effective lengths of all base materials can be fast computed in the forward ray-tracing process and be used repeatedly to obtain accurate polyenergetic projections, with which a SART-based equation can correctly update each voxel in the backward projecting process to iteratively reconstruct artifact-free images. This approach effectively reduces the influence of polyenergetic x-ray sources and it further enables monoenergetic images to be reconstructed at any arbitrarily preselected target energies. A series of simulation tests were performed on a size-variable cylindrical phantom and a realistic anthropomorphic thorax phantom. In addition, a phantom experiment was also performed on a clinical CT scanner to further quantitatively validate the proposed algorithm. Results: The simulations with the cylindrical phantom and the anthropomorphic thorax phantom showed that the proposed algorithm completely eliminated beam hardening artifacts and enabled quantitative imaging across different materials, phantom sizes, and spectra, as the absolute relative errors were reduced

  9. Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia

    Energy Technology Data Exchange (ETDEWEB)

    Maseri, A.; L' Abbate, A.; Pesola, A.; Michelassi, C.; Marzilli, M.; De Nes, M.

    1977-03-01

    We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of /sup 133/Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, poststenotic washout rates became much slower during angina than at rest, a finding that implicates functional factors in impairing poststenotic myocardial perfusion during angina.

  10. Optimization of OSEM parameters in myocardial perfusion imaging reconstruction as a function of body mass index: a clinical approach*

    Science.gov (United States)

    de Barros, Pietro Paolo; Metello, Luis F.; Camozzato, Tatiane Sabriela Cagol; Vieira, Domingos Manuel da Silva

    2015-01-01

    Objective The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients’ body mass index. Materials and Methods The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality. Results An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes. Conclusion The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient. PMID:26543282

  11. Relation between perfusion defects on stress technetium-99m sestamibi SPECT scintigraphy and the location of a subsequent acute myocardial infarction.

    Science.gov (United States)

    Miller, G L; Herman, S D; Heller, G V; Kalla, S; Levin, W A; Stillwell, K M; Travin, M I

    1996-07-01

    Although the presence of perfusion defects on stress myocardial perfusion imaging has been shown to correlate with future cardiac events, including acute myocardial infarction (AMI), it is unknown whether the location of the AMI can be predicted. Therefore, for 25 patients who had an AMI following a stress technetium-99m sestamibi single-photon emission computed tomographic (SPECT) imaging study and whose infarct location could be determined, the territory of infarction was correlated with the location of previous myocardial perfusion defects. A SPECT perfusion defect had been present in 24 patients (96%). The AMI occurred in territories that showed a reversible defect in 14 patients (56%), whereas 3 infarctions (12%) were in territories that revealed a fixed defect, and 8 infarctions (32%) were in territories that had not shown a defect on prior SPECT imaging. Whereas the incidence of infarction in territories with a reversible defect was highest at 14 of 26 (54%), the incidence of infarction in territories with a fixed defect was 3 of 7 (43%), and in territories with no defect was 8 of 42 (19%) (p = 0.011). Neither the time interval between SPECT imaging and infarction, nor the perfusion defect severity, was related to the correlation between perfusion defect and infarct location. Thus, although AMI occurs most often at the site of previous perfusion defects, reversible or fixed, a substantial percentage occur in territories without a perfusion defect. These findings suggest that abnormalities on SPECT perfusion imaging, although they serve as markers of significant coronary disease and increase the likelihood of infarction, do not always predict the exact location of infarction.

  12. Experimental and Clinical Research of Myocardial Protection Effect Using MHBC Perfusion

    Institute of Scientific and Technical Information of China (English)

    孟春营; 吴若彬; 罗滨; 温定国

    2004-01-01

    Objectives To determine the myocardium-protecting effect of medium hypothermal blood cardioplegia (MHBC); further demonstrates that the optimal temperature between these hypothermal and normothermic can overcome the disadvantages;and thus discovers a more effective myocardium protecting method. Methods Section 1: 14 mongrel dogs (15-20 kg) were randomly divided into two groups: experimental group and control group; cardialpulmonary bypass was conventionally instituted,moderate hypothermia blood cardioplegia was used in experimental group, Blood samples from right atrium taken for examination of lactate dehydrogenase (LDH)creatine kinase(CK-MB) and Topin I(cTn-I). specimens of left ventricular subendocardial myocardium were biopsied to observe changes of ultrastructure.Section 2:24 patients were randomly divided into two groups and both groups received two types of treatment (same as Section 1) after aorta cross-clamp (ACC). Biochemical index and Clinical observation were caculated as the indicators. Results In the experimental research, LDH, CK-MB, cTn-I were found increased after reperfusion in both groups, but the extent of changes in experimental group is tiny (statistical difference). Compared with control group the effect of MHBC on cardial function is little; the ultrastructure. of cardiac muscle has no obvious change. In the clinical research, compared the test results of venous blood drawn before CPB, after beating recovery and after CPB, CBC perfused group (LDH, CK-MB leak age and cTn-I value increase.) compared with MHBC perfused group had no remarkable difference (P>0.05), but at the result of clinical observation: MHBC perfused group had red, soft hearts after cardiac arrest but CBC perfused group had pale, spasmatic hearts after cardiac arrest; 0 case in MHBC perfused group and 3 cases in CBC perfused group had twitch-removing beat recovery; 11 cases in MHBC perfused group and 3 cases in CBC perfused group recovered sinus heart rhythm after surgery

  13. Optimization of the filter parameters in (99m)Tc myocardial perfusion SPECT studies: the formulation of flowchart.

    Science.gov (United States)

    Shibutani, Takayuki; Onoguchi, Masahisa; Yamada, Tomoki; Kamida, Hiroki; Kunishita, Kohei; Hayashi, Yuuki; Nakajima, Tadashi; Kinuya, Seigo

    2016-06-01

    Myocardial perfusion single photon emission computed tomography (SPECT) is typically subject to a variation in image quality due to the use of different acquisition protocols, image reconstruction parameters and image display settings by each institution. One of the principal image reconstruction parameters is the Butterworth filter cut-off frequency, a parameter strongly affecting the quality of myocardial images. The objective of this study was to formulate a flowchart for the determination of the optimal parameters of the Butterworth filter for filtered back projection (FBP), ordered subset expectation maximization (OSEM) and collimator-detector response compensation OSEM (CDR-OSEM) methods using the evaluation system of the myocardial image based on technical grounds phantom. SPECT studies were acquired for seven simulated defects where the average counts of the normal myocardial components of 45° left anterior oblique projections were approximately 10-120 counts/pixel. These SPECT images were then reconstructed by FBP, OSEM and CDR-OSEM methods. Visual and quantitative assessment of short axis images were performed for the defect and normal parts. Finally, we formulated a flowchart indicating the optimal image processing procedure for SPECT images. Correlation between normal myocardial counts and the optimal cut-off frequency could be represented as a regression expression, which had high or medium coefficient of determination. We formulated the flowchart in order to optimize the image reconstruction parameters based on a comprehensive assessment, which enabled us to perform objectively processing. Furthermore, the usefulness of image reconstruction using the flowchart was demonstrated by a clinical case.

  14. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation; Valoracion no invasiva de la enfermedad ateroesclerosa coronaria en pacientes con isquemia silente: utilidad del SPECT de perfusion miocardica. Correlacion electrica, angiografica y de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E. [Hospital Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico)

    2005-07-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis.

  15. Normal value of functional parameters in gated myocardial perfusion SPECT in patients with low risk of coronary artery disease: emory cardiac tool box program

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. Y.; Kim, M. H.; Kim, Y. D.; Kim, D. K. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    Absolute value of the functional data of gated myocardial perfusion SPECT is necessary to determine that individual patient is normal or not. Tc-99m MIBI gated myocardial perfusion SPECT was performed using emory cardiac tool box program. All patients (M:F=15:36, age 64{+-}10 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded; previous angina or MI, ECG change with Q wave or ST-T change, diabetes mellitus, hypercholesterolemia, typical chest pain and hypertension. In all patients, myocardial mass is 117{+-}23 g in stress gated SPECT, 106{+-}22 g in stress ungated SPECT and 102{+-}21 g in rest ungated SPECT. EDV is 90{+-}28 ml, ESV 26{+-}20 ml, SV 66{+-}21 ml, EF 73{+-}10 % and TID 1.06{+-}0.14. Myocardial mass in rest ungated SPECT is significantly different between men and women (p=0.025). Myocardial mass is significantly different between stress gated SPECT and stress ungated SPECT (p=0.000), and between stress ungated SPECT and rest ungated SPECT (p=0.003). We provide normal value of functional parameters to determine the abnormality of individual patients in patients with low risk of coronary artery disease.

  16. Non-rigid registration and KLT filter to improve SNR and CNR in GRE-EPI myocardial perfusion imaging.

    Science.gov (United States)

    Mihai, Georgeta; Ding, Yu; Xue, Hui; Chung, Yiu-Cho; Rajagopalan, Sanjay; Guehring, Jens; Simonetti, Orlando P

    2012-12-01

    The purpose of the study was to evaluate the effect of motion compensation by non-rigid registration combined with the Karhunen-Loeve Transform (KLT) filter on the signal to noise (SNR) and contrast-to-noise ratio (CNR) of hybrid gradient-echo echoplanar (GRE-EPI) first-pass myocardial perfusion imaging. Twenty one consecutive first-pass adenosine stress perfusion MR data sets interpreted positive for ischemia or infarction were processed by non-rigid Registration followed by KLT filtering. SNR and CNR were measured in abnormal and normal myocardium in unfiltered and KLT filtered images following non-rigid registration to compensate for respiratory and other motions. Image artifacts introduced by filtering in registered and nonregistered images were evaluated by two observers. There was a statistically significant increase in both SNR and CNR between normal and abnormal myocardium with KLT filtering (mean SNR increased by 62.18% ± 21.05% and mean CNR increased by 58.84% ± 18.06%; p = 0.01). Motion correction prior to KLT filtering reduced significantly the occurrence of filter induced artifacts (KLT only-artifacts in 42 out of 55 image series vs. registered plus KLT-artifacts in 3 out of 55 image series). In conclusion the combination of non- rigid registration and KLT filtering was shown to increase the SNR and CNR of GRE-EPI perfusion images. Subjective evaluation of image artifacts revealed that prior motion compensation significantly reduced the artifacts introduced by the KLT filtering process.

  17. Relationship between myocardial perfusion-gated SPECT and the performance of coronary revascularization in patients with ischemic cardiomyopathy.

    Science.gov (United States)

    Romero-Farina, Guillermo; Candell-Riera, Jaume; Aguadé-Bruix, Santiago; Ferreira-Gonzalez, Ignacio; Igual, Albert; García-Dorado, David

    2012-10-01

    Ischemic cardiomyopathy (ICM) is a disease with high morbidity and mortality. There are several published studies on the evolution and prognosis of patients with ICM. However, reports on the therapeutic management in clinical practice are scarce. The aim of this study was to analyze coronary revascularization (CR) performance in patients with ICM and suitable coronary anatomy according to myocardial perfusion stress-rest gated SPECT results. Eighty-seven consecutive patients (mean age, 62.4 y; 20 women), with ischemic heart disease, left ventricular ejection fraction of 40% or less, coronary anatomy suitable for CR, and without previous CR, were evaluated by means of stress-rest gated SPECT. Sixty-four percent of patients had scintigraphic criteria of viability and 62.1% showed scintigraphic ischemia in stress-rest gated SPECT. Forty-five percent of patients were revascularized, and the remainder received medical treatment only. Coronary revascularization was more frequent in patients with scintigraphic viability (P = 0.012), in those with scintigraphic ischemia (P = 0.007), and in those with low left ventricular end-systolic volume (P = 0.006). Cox regression analysis identified multivessel disease [hazard ratio (HR), 3.3; 95% confidence interval (CI), 4-7.8], summed difference score greater than 4 (HR, 3.9; 95% CI, 1.5-9.8), and left ventricular end-systolic volume less than 120 mL (HR, 3.2; 95% CI, 1.3-8.2) as the best independent predictors of CR treatment. In patients with ICM and suitable coronary arteries who are able to perform a stress myocardial perfusion-gated SPECT, the presence of multivessel disease and myocardial ischemia and the absence of severely increased left ventricular volume were associated to a decision of CR.

  18. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  19. The dream of a one-stop-shop : Meta-analysis on myocardial perfusion CT

    NARCIS (Netherlands)

    Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A. M.; Schoepf, U. Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2015-01-01

    Purpose: To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (

  20. 核素心肌灌注显像诊断无症状性心肌缺血价值%Value of nuclide myocardial perfusion imaging to the diagnosis of silent myocardial infarction

    Institute of Scientific and Technical Information of China (English)

    高玲; 贾鹏; 李爱梅

    2011-01-01

    目的 探讨核素心肌灌注显像诊断无症状性心肌缺血的临床应用价值.方法 动态心电图或其他心电检测技术检测无症状性心肌梗死患者22例,均行核素心肌灌注显像与冠状动脉造影检查,并以冠状动脉造影结果为金标准,计算核素心肌灌注显像结果预测值.结果22例患者中8例核素心肌灌注显像表现为不可逆性心肌缺血,14例表现为混合性心肌缺血,共检测出40个节段病变心肌.冠状动脉造影检出阳性血管45支(血管狭窄程度≥50%),其中28支狭窄程度>90%,15支狭窄程度>70%~90%,2支狭窄程度≤70%.核素心肌灌注显像阳性结果预测值为88.9%(40/45).结论 核素心肌灌注显像有助于无症状性心肌缺血诊断,并可用于评价心肌损害严重程度.%Objective To study the clinical value of nuclide myocardial perfusion imaging to the diagnosis of silent myocardial infarction. Methods Twenty-two patients with silent myocardial infarction received gated nuclide myocardial perfusion imaging and coronary angiography, and the predictive value was calculated on the basis of coronary angiographic results. Results In 22 cases receiving nuclide myocardial perfusion imaging, irreversible myocardial ischemia was found in 8 cases, and mixed ischemia was found in 14 cases. A total of 40 diseased myocardial segments were found. Coronary angiography showed stenosis was above 50% in 45 arterial vessels, in which stenosis was above 90% in 28 arterial vessels, and was between 90% and 70% in 15 arterial vessels, and was below 70% in 2 arterial vessels. The positive predictive rate of nuclide myocardial perfusion imaging was 88. 9%. Conclusion Nuclide myocardial perfusion imaging has significant clinical value to the diagnosis of silent myocardial infarction and evaluation of myocardial damage.

  1. Dynamic myocardial perfusion in a porcine balloon-induced ischemia model using a prototype spectral detector CT

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Fares, Anas; Levi, Jacob; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2015-03-01

    Myocardial CT perfusion (CTP) imaging is an application that should greatly benefit from spectral CT through the significant reduction of beam hardening (BH) artifacts using mono-energetic (monoE) image reconstructions. We used a prototype spectral detector CT (SDCT) scanner (Philips Healthcare) and developed advanced processing tools (registration, segmentation, and deconvolution-based flow estimation) for quantitative myocardial CTP in a porcine ischemia model with different degrees of coronary occlusion using a balloon catheter. The occlusion severity was adjusted with fractional flow reserve (FFR) measurements. The SDCT scanner is a single source, dual-layer detector system, which allows simultaneous acquisitions of low and high energy projections, hence enabling accurate projection-based material decomposition and effective reduction of BH-artifacts. In addition, the SDCT scanner eliminates partial scan artifacts with fast (0.27s), full gantry rotation acquisitions. We acquired CTP data under different hemodynamic conditions and reconstructed conventional 120kVp images and projection-based monoenergetic (monoE) images for energies ranging from 55keV-to-120keV. We computed and compared myocardial blood flow (MBF) between different reconstructions. With balloon completely deflated (FFR=1), we compared the mean attenuation in a myocardial region of interest before iodine arrival and at peak iodine enhancement in the left ventricle (LV), and we found that monoE images at 70keV effectively minimized the difference in attenuation, due to BH, to less than 1 HU compared to 14 HU with conventional 120kVp images. Flow maps under baseline condition (FFR=1) were more uniform throughout the myocardial wall at 70keV, whereas with 120kVp data about 12% reduction in blood flow was noticed on BH-hypoattenuated areas compared to other myocardial regions. We compared MBF maps at different keVs under an ischemic condition (FFR ratio (CNRf ) between LAD ischemic and remote healthy

  2. Impaired coronary flow reserve is the most important marker of viable myocardium in the myocardial segment-based analysis of dual-isotope gated myocardial perfusion single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Woo [Dept. of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University School of Medicine, Seoul (Korea, Republic of); Kim, Ki Bong; Lee, Dong Soo [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    The aim of this study was to investigate the most robust predictor of myocardial viability among stress/rest reversibility (coronary flow reserve [CFR] impairment), {sup 201}Tl perfusion status at rest, {sup 201}Tl 24 hours redistribution and systolic wall thickening of {sup 99m}Tc-methoxyisobutylisonitrile using a dual isotope gated myocardial perfusion single-photon emission computed tomography (SPECT) in patients with coronary artery disease (CAD) who were re-vascularized with a coronary artery bypass graft (CABG) surgery. A total of 39 patients with CAD was enrolled (34 men and 5 women), aged between 36 and 72 years (mean 58 ± 8 standard in years) who underwent both pre- and 3 months post-CABG myocardial SPECT. We analyzed 17 myocardial segments per patient. Perfusion status and wall motion were semi-quantitatively evaluated using a 4-point grading system. Viable myocardium was defined as dysfunctional myocardium which showed wall motion improvement after CABG. The left ventricular ejection fraction (LVEF) significantly increased from 37.8 ± 9.0% to 45.5 ± 12.3% (p < 0.001) in 22 patients who had a pre-CABG LVEF lower than 50%. Among 590 myocardial segments in the re-vascularized area, 115 showed abnormal wall motion before CABG and 73.9% (85 of 115) had wall motion improvement after CABG. In the univariate analysis (n = 115 segments), stress/rest reversibility (p < 0.001) and {sup 201}Tl rest perfusion status (p = 0.024) were significant predictors of wall motion improvement. However, in multiple logistic regression analysis, stress/rest reversibility alone was a significant predictor for post-CABG wall motion improvement (p < 0.001). Stress/rest reversibility (impaired CFR) during dual-isotope gated myocardial perfusion SPECT was the single most important predictor of wall motion improvement after CABG.

  3. Myocardial perfusion abnormality and effects of Ca channel blockers on myocardial ischemia in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Yoko [Kyoto Prefectural Univ. of Medicine (Japan)

    1997-03-01

    The purpose of this study was to investigate the frequency of myocardial ischemia and characteristic regions of myocardial hypoperfusion during stress in patients with hypertrophic cardiomyopathy. Furthermore, the effects of Ca channel blocker (verapamil, diltiazem) on myocardial ischemia were studied. One hundred patients with hypertrophic cardiomyopathy underwent exercise {sup 201}Tl SPECT. Sixty-eight patients had one or more {sup 201}Tl abnormalities. Of the 68 patients with {sup 201}Tl abnormalities, 56 had reversible {sup 201}Tl abnormalities and 12 had fixed defect. {sup 201}Tl abnormalities were frequently distributed in the anterior and posterior areas of junction between the ventricular septum and the free wall and the apex. Of the 56 patients with reversible {sup 201}Tl abnormalities, 40 patients underwent one more exercise {sup 201}Tl SPECT after 8 weeks of oral administration of verapamil or diltiazem. The {sup 201}Tl defect was visually scored as the defect score. Transient dilation index was calculated as an index of subendocardial ischemia. The mean defect score decreased significantly from 9.80{+-}4.35 to 5.50{+-}4.63 after verapamil and from 9.90{+-}5.17 to 5.50{+-}4.89 after diltiazem. Mean transient dilation index decreased from 1.20{+-}0.12 to 1.08{+-}0.09 after treatment with verapamil and from 1.16{+-}0.10 to 1.02{+-}0.09 after treatment with diltiazem. (K.H.)

  4. Detection and severity classification of extracardiac interference in {sup 82}Rb PET myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orton, Elizabeth J., E-mail: eorton@physics.carleton.ca; Kemp, Robert A. de; Glenn Wells, R. [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Department of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6 (Canada); Al Harbi, Ibraheem [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Department of Medicine (Cardiology), King Fahad Hospital, Medina 42351 (Saudi Arabia); Klein, Ran [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Department of Biomedical Engineering, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6 (Canada); Beanlands, Rob S. B. [Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada)

    2014-10-15

    Purpose: Myocardial perfusion imaging (MPI) is used for diagnosis and prognosis of coronary artery disease. When MPI studies are performed with positron emission tomography (PET) and the radioactive tracer rubidium-82 chloride ({sup 82}Rb), a small but non-negligible fraction of studies (∼10%) suffer from extracardiac interference: high levels of tracer uptake in structures adjacent to the heart which mask the true cardiac tracer uptake. At present, there are no clinically available options for automated detection or correction of this problem. This work presents an algorithm that detects and classifies the severity of extracardiac interference in {sup 82}Rb PET MPI images and reports the accuracy and failure rate of the method. Methods: A set of 200 {sup 82}Rb PET MPI images were reviewed by a trained nuclear cardiologist and interference severity reported on a four-class scale, from absent to severe. An automated algorithm was developed that compares uptake at the external border of the myocardium to three thresholds, separating the four interference severity classes. A minimum area of interference was required, and the search region was limited to that facing the stomach wall and spleen. Maximizing concordance (Cohen’s Kappa) and minimizing failure rate for the set of 200 clinician-read images were used to find the optimal population-based constants defining search limit and minimum area parameters and the thresholds for the algorithm. Tenfold stratified cross-validation was used to find optimal thresholds and report accuracy measures (sensitivity, specificity, and Kappa). Results: The algorithm was capable of detecting interference with a mean [95% confidence interval] sensitivity/specificity/Kappa of 0.97 [0.94, 1.00]/0.82 [0.66, 0.98]/0.79 [0.65, 0.92], and a failure rate of 1.0% ± 0.2%. The four-class overall Kappa was 0.72 [0.64, 0.81]. Separation of mild versus moderate-or-greater interference was performed with good accuracy (sensitivity

  5. Comparative value of brain perfusion SPECT and [{sup 123}I]MIBG myocardial scintigraphy in distinguishing between dementia with Lewy bodies and Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Shimizu, Soichiro; Hirao, Kentaro; Kanetaka, Hidekazu; Iwamoto, Toshihiko [Tokyo Medical University, Department of Geriatric Medicine, Tokyo (Japan); Chikamori, Taishiro; Usui, Yasuhiro; Yamashina, Akira [Tokyo Medical University, 2. Department of Internal Medicine, Tokyo (Japan); Koizumi, Kiyoshi; Abe, Kimihiko [Tokyo Medical University, Department of Radiology, Tokyo (Japan)

    2006-03-15

    Both decreased occipital perfusion on brain single-photon emission computed tomography (SPECT) and reduction in cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) uptake are characteristic features of dementia with Lewy bodies (DLB), and potentially support the clinical diagnosis of DLB. The aim of this study was to compare the diagnostic value of these two methods for differentiation of DLB from Alzheimer's disease (AD). The study population comprised 19 patients with probable DLB and 39 patients with probable AD who underwent both SPECT with N-isopropyl-p-[{sup 123}I]iodoamphetamine and MIBG myocardial scintigraphy. Objective and quantitative measurement of perfusion in the medial occipital lobe, including the cuneus and lingual gyrus, was performed by the use of three-dimensional stereotactic surface projections. Medial occipital perfusion was significantly decreased in the DLB group compared with the AD group. The mean heart/mediastinum ratios of MIBG uptake were significantly lower in the DLB group than in the AD group. Although SPECT failed to demonstrate significant hypoperfusion in the medial occipital lobe in five patients with DLB, marked reduction of MIBG uptake was found in all patients with DLB. Receiver operating characteristic analysis revealed that MIBG myocardial scintigraphy enabled more accurate discrimination between DLB and AD than was possible with perfusion SPECT. MIBG myocardial scintigraphy may improve the sensitivity in the detection of DLB. In particular, this method may provide a powerful differential diagnostic tool when it is difficult to distinguish cases of DLB from AD using brain perfusion SPECT. (orig.)

  6. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates.

  7. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  8. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography: design and implementation of the CORE320 multicenter, multinational diagnostic study.

    Science.gov (United States)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T; Rochitte, Carlos E; Arai, Andrew E; Miller, Julie M; Di Carli, Marcello; Arbab-Zadeh, Armin; Zadeh, Armin A; Dewey, Marc; Niinuma, Hiroyuki; Laham, Roger; Rybicki, Frank J; Schuijf, Joanne D; Paul, Narinder; Hoe, John; Kuribyashi, Sachio; Sakuma, Hajime; Nomura, Cesar; Yaw, Tan Swee; Kofoed, Klaus F; Yoshioka, Kunihiro; Clouse, Melvin E; Brinker, Jeffrey; Cox, Christopher; Lima, Joao A C

    2011-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8 countries worldwide. CT has the potential to assess both anatomy and physiology in a single imaging session. The co-primary aim of the CORE320 study is to define the per-patient diagnostic accuracy of the combination of coronary CTA and myocardial CTP to detect physiologically significant coronary artery disease compared with (1) the combination of conventional coronary angiography and SPECT-MPI and (2) conventional coronary angiography alone. If successful, the technology could revolutionize the management of patients with symptomatic CAD.

  9. A Comparison between Quantitative Gated Myocardial Perfusion Scintigraphy and Strain Echocardiography as Indicators of Ventricular Functions in Patients with Anterior Myocardial Infarction

    Science.gov (United States)

    Karacavus, Seyhan; Celik, Ahmet; Tutus, Ahmet; Kula, Mustafa; Oguzhan, Abdurrahman; Ozdogru, Ibrahim; Kalay, Nihat

    2014-01-01

    The purpose of this study is to compare the strain echocardiographic and scintigraphic parameters for evaluating of the left ventricular (LV) functions in patients with anterior myocardial infarction (MI). Fifty-four patients (male/female: 36/18; mean age 62 ± 13 years) with anterior MI were prospectively enrolled. All patients were performed gated myocardial perfusion scintigraphy gated single-photon emission computed tomography (GSPECT) and echocardiography (EC). GSPECT data were processed and analyzed using 4D-MSPECT (4DM, Invia Medical Imaging Solutions, Ann Arbor, MI, USA). The echocardiographic strain (S) and strain rate (SR) values were calculated. The results obtained by these techniques were compared each other. A total of 918 segments of LV wall were evaluated. In all patients, 385 segments were automatically scored as normokinetic, 206 as hypokinetic, 122 as akinetic, 205 as dyskinetic and 300 as normal thickening, 348 as decrease thickening and 270 as no thickening. The means of S and SR values in thickening and motion score groups according to GSPECT were statistically different from each other (P < 0.001). There was a negative significant correlation between LV wall thickening sum score and S and SR and between LV wall motion sum score and S and SR (P < 0.001). There was a good correlation between GSPECT and echocardiographic LV-ejection fraction (r = 0.7, P < 0.001). GSPECT and strain EC are similar in quantitative grading of the severity of regional and global myocardial dysfunction in patients with anterior MI and these techniques provide valuable diagnostic information. PMID:25538490

  10. [Variables that influence the indication of a second myocardial perfusion gated-SPECT after a normal stress-rest gated SPECT].

    Science.gov (United States)

    Romero-Farina, G; Candell-Riera, J; Aguadé-Bruix, S; Cuberas-Borrós, G; Pizzi, M N; Santos, A; de León, G; García-Dorado, D

    2014-01-01

    The objective of this study was to investigate predictor variables at the moment of normal stress-rest myocardial perfusion gated SPECT for indication of a second gated SPECT. A prospective, single center cohort study was conducted. We evaluated 2326 consecutive patients (age 63.6 ± 13 years, 57.3% females) without perfusion defects and with normal left ventricular ejection fraction on a myocardial perfusion gated SPECT. Clinical and stress test variables were studied to predict indication of a second gated SPECT and presence of reversible perfusion defects in the second gated SPECT. During a mean follow-up of 3.6 ± 2 years a second gated SPECT was performed in 286 patients (12.3%). Independent predictor variables of a second gated SPECT were presence of three or more cardiovascular risk factors (χ(2): 5.510; HR: 1.4; p=0.019), previous acute myocardial infarction (χ(2): 3.867; HR: 1.4; p=0.049), previous coronary revascularization (χ(2): 41.081; HR: 2.5; p<0.001), and a positive stress test (χ(2): 8.713; HR: 1.5; p=0.003). Observation of perfusion defects in the 280 patients in whom a second stress-rest gated SPECT was performed was more likely in male patients (χ(2): 4.322; HR: 1.9; p=0.038) who had a first pure pharmacological gated-SPECT (χ(2): 7.182; HR: 2.6; p=0.007). In patients with a first normal myocardial perfusion gated SPECT, various clinical factors and variables derived from the stress test affect the indication of a second gated SPECT and the presence of ischemia in the latter. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  11. Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients

    Energy Technology Data Exchange (ETDEWEB)

    D' Agostino, A.G.; Remy-Jardin, M.; Khalil, C.; Remy, J. [University Center of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Delannoy-Deken, V.; Duhamel, A. [University of Lille, Department of Medical Statistics, Lille (France); Flohr, T. [Siemens Medical, Research and Development Department, CT Division, Forchheim (Germany)

    2006-10-15

    The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient's size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [{+-}standard deviation (SD)] body mass index (BMI) of 24.47 ({+-}4.64); (b) a mean ({+-}SD) heart rate of 72.04 ({+-}15.76) bpm; (c) a mean ({+-}SD) scanning time of 18.3 ({+-}2.73) s; (d) a mean ({+-}SD) dose-length product (DLP) value of 260.57 ({+-}83.67) mGy/cm; (e) an estimated average effective dose of 4.95 ({+-}1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of

  12. Myocardial perfusion of infarcted and normal myocardium in propofol-anesthetized minipigs using 82Rubidium PET

    DEFF Research Database (Denmark)

    Rasmussen, Thomas; Larsen, Bjarke Follin; Kastrup, Jens

    2016-01-01

    propofol, used for anesthesia, can influence myocardial perfusion and coronary flow reserve due to its vasorelaxant effect, and interactions might exist between propofol and used stress agents, potentially affecting the result of the examination. We present cardiac 82Rb-PET studies performed in propofol...... challenges. Animals, which have been anesthetized during PET acquisition, might react differently to used stress medications, and therefore difficulties might exist while evaluating the resulting PET images using standard software packages from commercial vendors optimized for human hearts. Furthermore......-anesthetized minipigs with normal and infarcted myocardium stressed with both adenosine and dipyridamole. Despite the mentioned challenges, we were able to trace the small minipig heart with software designed for human cardiac PET and to achieve blood flow measurements comparable with results in humans with both...

  13. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  14. Clinical evaluation of the computed tomography attenuation correction map for myocardial perfusion imaging: the potential for incidental pathology detection.

    Science.gov (United States)

    Tootell, Andrew; Vinjamuri, Sobhan; Elias, Mark; Hogg, Peter

    2012-11-01

    The benefits of hybrid imaging in nuclear medicine have been proven to increase the diagnostic accuracy and sensitivity of many procedures by localizing or characterizing lesions or by correcting emission data to more accurately represent radiopharmaceutical distribution. Single-photon emission computed tomography/computed tomography (SPECT/CT) has a significant role in the diagnosis and follow-up of ischaemic heart disease with attenuation correction data being obtained on an integrated CT scanner. Initially, the CT component of hybrid SPECT/CT systems was what could be described as low specification utilizing fixed output parameters. As technology has progressed, the CT component of newer systems has specifications that are identical to that of stand-alone diagnostic systems. Irrespective of the type of scanner used, the computed tomography attenuation correction (CTAC) for myocardial perfusion imaging produces low-quality, limited-range CT images of the chest that include the mediastinum, lung fields and surrounding soft tissues. The diagnostic potential of this data set is unclear; yet, examples exist whereby significant pathology can be identified and investigated further. Despite guidance from a number of professional bodies suggesting that evaluation of the resulting images for every medical exposure be carried out, there is no indication as to whether this should include the evaluation of CTAC images. This review aims to initiate discussion by examining the ethical, legal, financial and practical issues (e.g. CT specification and image quality) surrounding the clinical evaluation of the CTAC for myocardial perfusion imaging images. Reference to discussions that have taken place, and continue to take place, in other modalities, current European and UK legislations, and guidelines and research in the field will be made.

  15. Comparative analysis of iterative reconstruction algorithms with resolution recovery and new solid state cameras dedicated to myocardial perfusion imaging.

    Science.gov (United States)

    Brambilla, Marco; Lecchi, Michela; Matheoud, Roberta; Leva, Lucia; Lucignani, Giovanni; Marcassa, Claudio; Zoccarato, Orazio

    2017-03-23

    New technologies are available in myocardial perfusion imaging. They include new software that recovers image resolution and limits image noise, multifocal collimators and dedicated cardiac cameras in which solid-state detectors are used and all available detectors are constrained to imaging just the cardiac field of view. These innovations resulted in shortened study times or reduced administered activity to patients, while preserving image quality. Many single center and some multicenter studies have been published during the introduction of these innovations in the clinical practice. Most of these studies were lead in the framework of "agreement studies" between different methods of clinical measurement. They aimed to demonstrate that these new software/hardware solutions allow the acquisition of images with reduced acquisition time or administered activity with comparable results (as for image quality, image interpretation, perfusion defect quantification, left ventricular volumes and ejection fraction) to the standard-time or standard-dose SPECT acquired with a conventional gamma camera and reconstructed with the traditional FBP method, considered as the gold standard. The purpose of this review is to provide the reader with a comprehensive understanding of the pro and cons of the different approaches summarizing the achievements reached so far and the issues that need further investigations.

  16. Direct comparison of stress- and rest-dual-energy computed tomography for detection of myocardial perfusion defect.

    Science.gov (United States)

    Ko, Sung Min; Park, Jeong Hee; Hwang, Hweung Kon; Song, Meong Gun

    2014-06-01

    We assessed the diagnostic performance of stress- and rest-dual-energy computed tomography (DECT) and their incremental value when used with coronary CT angiography (CCTA) compared with combined invasive coronary angiography (ICA)/cardiovascular magnetic resonance (CMR) for detecting hemodynamically significant stenosis causing a myocardial perfusion defect. Forty patients (30 men; mean age, 63.4 ± 8.8 years) with known or suspected coronary artery disease detected by CCTA underwent stress- and rest-DECT, CMR, and ICA. DECT iodine maps were compared with CMR on a per-segment and per-vessel basis. Diagnostic value of CCTA was assessed on a per-vessel basis before and after stress- and rest-DECT and compared to that of ICA/CMR. Compared to CMR, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of rest-DECT for detecting segment (vessel)-based perfusion defects were 29% (46%), 88% (79%), 56% (61%), and 70% (67%), respectively. Corresponding values using stress-DECT were 73% (94%), 83% (74%), 70% (72%), and 85% (95%), respectively. There was fair (κ = 0.39) agreement between rest- and stress-DECT iodine maps in identifying segments with perfusion defects. Compared with the ICA/CMR for identifying hemodynamically significant stenoses, per-vessel territory sensitivity, specificity, PPV, and NPV of CCTA were 91, 56, 55, and 91%, respectively; those using CCTA/rest-DECT were 42, 83, 59, and 70%, respectively; and those using CCTA/stress-DECT were 87, 79, 71, and 91%, respectively. The area under the receiver operating characteristic curve decreased from 0.74 to 0.62 (P = 0.06) using CCTA/rest-DECT but increased to 0.83 (P = 0.02) using CCTA/stress-DECT. Stress-DECT has incremental value when used with CCTA for detecting hemodynamically significant stenoses.

  17. Increased accuracy of single photon emission computed tomography (SPECT myocardial perfusion scintigraphy using iterative reconstruction of images

    Directory of Open Access Journals (Sweden)

    Stević Miloš

    2016-01-01

    Full Text Available Background/Aim. Filtered back projection (FBP is a common way of processing myocardial perfusion imaging (MPI studies. There are artifacts in FBP which can cause falsepositive results. Iterative reconstruction (IR is developed to reduce false positive findings in MPI studies. The aim of this study was to evaluate the difference in the number of false positive findings in MPI studies, between FBP and IR processing. Methods. We examined 107 patients with angina pectoris with MPI and coronary angiography (CAG, 77 man and 30 woman, aged 32−82. MPI studies were processed with FBP and with IR. Positive finding at MPI was visualization of the perfusion defect. Positive finding at CAG was stenosis of coronary artery. Perfusion defect at MPI without coronary artery stenosis at CAG was considered like false positive. The results were statistically analyzed with bivariate correlation, and with one sample t-test. Results. There were 20.6% normal, and 79.4% pathologic findings at FBP, 30.8% normal and 69.2% pathologic with IR and 37.4% normal and 62.6% pathologic at CAG. FBP produced 19 false-positive findings, at IR 11 false positive findings. The correlation between FBP and CAG was 0.658 (p < 0.01 and between IR and CAG 0.784 (p < 0.01. The number of false positive findings at MPI with IR was significantly lower than at FBP (p < 0.01. Conclusion. Our study shows that IR processing MPI scintigraphy has less number of false positive findings, therefore it is our choice for processing MPI studies.

  18. Image Registration and Analysis for Quantitative Myocardial Perfusion: Application to Dynamic Circular Cardiac CT

    NARCIS (Netherlands)

    Isola, A.; Schmitt, H.; Van Stevendaal, U.; Begemann, P.G.C.; Coulon, P.; Boussel, L.; Grass, M.

    2012-01-01

    Large area detector computed tomography systems with fastrotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce X-ray dose andlimit motion artifacts. Even in the case

  19. Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia

    DEFF Research Database (Denmark)

    Sørgaard, Mathias Holm; Kofoed, Klaus Fuglsang; Linde, Jesper James

    2016-01-01

    : Systematic literature review and meta-analysis of studies examining the diagnostic accuracy of static CTP imaging alone or combined with coronary CT angiography (CTA) in comparison to single photon emission computed tomography (SPECT), magnetic resonance perfusion (MRP), and/or invasive coronary angiography...

  20. Image Registration and Analysis for Quantitative Myocardial Perfusion: Application to Dynamic Circular Cardiac CT

    NARCIS (Netherlands)

    Isola, A.; Schmitt, H.; Van Stevendaal, U.; Begemann, P.G.C.; Coulon, P.; Boussel, L.; Grass, M.

    2012-01-01

    Large area detector computed tomography systems with fastrotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce X-ray dose andlimit motion artifacts. Even in the case