WorldWideScience

Sample records for ecc injection experiments

  1. Experiments on injection performance of SMART ECC facility using SWAT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Min, Kyoung Ho; Shin, Yong Cheol; Kwon, Tae Soon; Yi, Sung Jae; Lee, Won Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    SMART (System-integrated Modular Advanced ReacTor), an advanced integrated PWR is now in the under developing stages by KAERI. Such integral PWR excludes large-size piping of the primary system of conventional PWR and incorporates the SGs into RPV, which means no LBLOCA could occur in SMART. Therefore, the SBLOCA is considered as a major DBA (Design Basis Accident) in SMART and it is mainly analyzed by using TASS/SMR computer code. The TASS/SMR code should be validated using experimental data from both Integral Effect Test and Separate Effect Test facilities. To investigate injection performance of the ECC system, on SET facility, named as SWAT (SMART ECC Water Asymmetric Two-phase choking test facility), has been constructed at KAERI. The SWAT simulates the geometric configurations of the SG-side upper downcomer annulus and ECCSs of those of SMART. It is designed based on the modified linear scaling method with a scaling ratio of 1/5, to preserve the geometrical similarity and minimize gravitational distortion. The purpose of the SWAT tests is to investigate the safety injection performance, such as the ECC bypass in the downcomer and the penetration rate in the core during the SBLOCA, and hence to produce experimental data to validate and the prediction capability of safety analysis codes, TASS/SMR

  2. Experiment data report for Semiscale Mod-1 Test S-05-1 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-1 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-1 was conducted from initial conditions of 2263 psia and 544 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the vessel lower plenum to simulate emergency core coolant injection in a PWR, with the flow rate based on system volume scaling

  3. Experiment data report for Semiscale Mod-1 Test S-05-2 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Collins, B.L.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-2 of the Semiscale Mod-1 alternate emergency core coolant (ECC) injection test series. This test is one of several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-2 was conducted from an initial cold leg fluid temperature of 545 0 F and an initial pressure of 2263 psia. A simulated double-ended offset shear cold leg break was used to investigate core and system response to a depressurization and reflood transient with ECC injection at the intact loop pump suction and broken loop cold leg. A reduced lower plenum volume was used for this test to more accurately represent the lower plenum of a PWR, based on system volume scaling. System flow was set to achieve a core fluid temperature differential of 65 0 F at a core power level of 1.44 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a slightly peaked radial power profile was used in the pressure vessel to simulate the predicted surface heat flux of nuclear fuel rods during a loss-of-coolant accident

  4. Experiment data report for Semiscale Mod-1 Test S-05-5 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Patton, M.L. Jr.; Sackett, K.E.

    1977-04-01

    Recorded test data are presented for Test S-05-5 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-5 was conducted from initial conditions of 2263 psia and 537 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. The upper plenum was vented through a reflood bypass line interconnecting the hot and cold legs of the broken loop

  5. Experiment data report for Semiscale Mod-1 Test S-05-3 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-03-01

    Recorded test data are presented for Test S-05-3 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-3 was conducted from initial conditions of 2263 psia and 545 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg sides of the intact and broken loops and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. For Test S-05-3, specifically the effects of upper plenum coolant injection on core thermal and system response were being investigated

  6. Investigation of Characteristics of Impinging Jet for 1/5-Scale ECC injection

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Soo; Ko, Yung Joo; Bae, Hwang; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-05-15

    In ECCS of SMART reactor, safety injection pump discharges cooling water into the core to maintain the water level by filling the amount of loss of coolant under emergency situation such as SBLOCA. Once the ECCS starts to operate, the injected water will be impinged to the upper wall of core support barrel (CBS). And the water will fall along the wall forming liquid film or droplets as shown in Fig. 1(b) due to high Reynolds number. The breakup and film flow will be bypassed by high temperature and pressure steam-water mixture cross flow from RCP discharge into the atmosphere through broken injection nozzle. Then, the flow phenomena in the downcomer is very complex situation with including jet impingement, jet breakup, liquid entrainment, steam condensation, counter-current flow and etc. In this study, the hydraulic features of impinging jet were investigated through visualization for full scale test for simulation of SMART ECC jet and SWAT test of 1/5 simulated test for ECCS of SMART reactor and measurement of the film width. And the scaling method for SWAT test was discussed considering jet break up and other phenomena

  7. UPTF-TRAM test A3. Turn-over of the hot-leg injected ECC in the steam generator direction

    International Nuclear Information System (INIS)

    Tenckhoff; Brand, B.; Weiss, P.

    1993-06-01

    The UPTF TRAM test A3 was a separate effects test to investigate the interaction between the hot leg-injected ECC and the single-phase or two-phase natural circulation in the hot leg in the case of an SBLOCA in a PWR. The experimental investigation of 7 runs was mainly concentrated on the following phenomena: - Transport of hot leg injected ECC water to the upper plenum or in the direction of steam generator, depending on the loop mass flow, -Utilization of the condensation potential of ECC water, - Mixing of the saturated water with the ECC water, - Effect of hot leg injection on the flow phenomena in the hot leg, - Effect of pressure (3 and 15 bar) on the scaling and hence the verification of the scaling concept applied. A preliminary evaluation of the test is presented in the Quick Look Report. (orig.) [de

  8. Diablo Canyon ECCS enhancements

    International Nuclear Information System (INIS)

    Lin, A.; Lee, T.P.; Walter, L.E.

    2004-01-01

    Diablo Canyon Power Plant (DCPP) operated by Pacific Gas and Electric Co. (PG and E) is a Westinghouse designed four loop plant. In recent years, several issues were identified regarding the compliance of the Emergency Core Cooling System (ECCS) surveillance tests to the ECCS analyses assumptions. These concerns are related mostly to the High Head Safety Injection (HHSI) and the Intermediate Head Safety Injection (IHSI) systems where the injection line throttle valves are adjusted during outage surveillance testing to ensure compliance with the Technical Specifications (TS). To resolve all of the identified issues PG and E performed an ECCS reanalysis and upgraded the ECCS surveillance test program and also had Westinghouse perform a containment reanalysis using their latest model. As a result of these plant specific enhancement efforts, DCPP widened the operating window for TS surveillance testing, lowered the ECCS pumps' acceptance performance curves, and re-gained Peak Clad Temperature (PCT) and containment peak pressure margins. These enhancements are generically applicable to other plants and are addressed in this paper. (author)

  9. Method of injecting cooling water in emergency core cooling system (ECCS) of PWR type reactor

    International Nuclear Information System (INIS)

    Sobajima, Makoto; Adachi, Michihiro; Tasaka, Kanji; Suzuki, Mitsuhiro.

    1979-01-01

    Purpose: To provide a cooling water injection method in an ECCS, which can perform effective cooling of the reactor core. Method: In a method of injecting cooling water in an ECCS as a countermeasure against a rupture accident of a pwr type reactor, cooling water in the first pressure storage injection system is injected into the upper plenum of the reactor pressure vessel at a set pressure of from 50 to 90 atg. and a set temperature of from 80 to 200 0 C, cooling water in the second pressure storage injection system is injected into the lower plenum of the reactor pressure vessel at a pressure of from 25 to 60 atg. which is lower than the set pressure and a temperature less than 60 0 C, and further in combination with these procedures, cooling water of less than 60 0 C is injected into a high-temperature side piping, in the high-pressure injection system of upstroke of 100 atg. by means of a pump and the low-pressure injection system of upstroke of 20 atg. also by means of a pump, thereby cooling the reactor core. (Aizawa, K.)

  10. Condensation during gravity driven ECC: Experiments with PACTEL

    Energy Technology Data Exchange (ETDEWEB)

    Munther, R.; Kalli, H. [Lappeenranta Univ. of Technology (Finland); Kouhia, J. [Technical Research Centre of Finland, Lappeenranta (Finland)

    1995-09-01

    This paper provides the results of the second series of gravity driven emergency core cooling (ECC) experiments with PACTEL (Parallel Channel Test Loop). The simulated accident was a small break loss-of-coolant accident (SBLOCA) with a break in a cold leg. The ECC flow was provided from a core makeup tank (CMT) located at a higher elevation than the main part of the primary system. The CMT was pressurized with pipings from the pressurizer and a cold leg. The tests indicated that steam condensation in the CMT can prevent ECC and lead to core uncovery.

  11. ECC delivery to lower plenum under downcomer injection part 2. RELAP5 assessment

    International Nuclear Information System (INIS)

    Bang, Young Seok; Shin, An Dong; Kim, Hho Jung

    2000-01-01

    In the present study, the capability of the thermal-hydraulic codes, RELAP5/MOD3.2.2 gamma, in predicting the steam-water interaction and the related ECC delivery to lower plenum under downcomer injection condition during refill phase is evaluated using the experimental data of the UPTF Test 21A. The facility is modeled in detail, and the test condition simulated for code calculations. The calculation result is compared with the applicable measurement data and discussed for the pressure response, ECC bypass behavior, lower plenum delivery, global water mass distribution, and local behavior in downcomer

  12. Numerical study of hot-leg ECC injection into the upper plenum of a pressurized water reactor

    International Nuclear Information System (INIS)

    Daly, B.J.; Torrey, M.D.; Rivard, W.C.

    1981-01-01

    In certain pressurized water reactor (PWR) designs, emergency core coolant (ECC) is injected through the hot legs into the upper plenum. The condensation of steam on this subcooled liquid stream reduces the pressure in the hot legs and upper plenum and thereby affects flow conditions throughout the reactor. In the present study, we examine countercurrent steam-water flow in the hot leg to determine the deceleration of the ECC flow that results from an adverse pressure gradient and from momentum exchange from the steam by interfacial drag and condensation. For the parameters examined in the study, water flow reversal is observed for a pressure drop of 22 to 32 mBar over the 1.5 m hot leg. We have also performed a three-dimensional study of subcooled water injection into air and steam environments of the upper plenum. The ECC water is deflected by an array of cylindrical guide tubes in its passage through the upper plenum. Comparisons of the air-water results with data obtained in a full scale experiment shows reasonable agreement, but indicates that there may be too much resistance to horizontal flow about the columns because of the use of a stair-step representation of the cylindrical guide tube cross section. Calculations of flow past single columns of stair-step, square and circular cross section do indicate excessive water deeentrainment by the noncircular column. This has prompted the use of an arbitrary mesh computational procedure to more accuratey represent the circular cross-section guide tubes. 15 figures

  13. Direct ECC bypass phenomena in the MIDAS test facility during LBLOCA reflood phase

    International Nuclear Information System (INIS)

    Yun, B. J.; Kweon, T. S.; Ah, D. J.; Ju, I. C.; Song, C. H.; Park, J. K.

    2001-01-01

    This paper describes the experimental results of ECC Direct Bypass Phenomena in the downcomer during the late reflood phase of LBLOCA of the reactor that adopts Direct Vessel Injection as a ECC system. The experiments have been performed in MIDAS test facility using superheated steam and water. The test condition was determined, based on the preliminary analysis of TRAC code, from modified linear scaling method of 1/4.93 length scale. To measure the direct bypass fraction according to the nozzle location, separate effect tests have been performed in case of DVI-4(farthest from broken cold leg) injection, DVI-2(closest to broken cold leg) injection, and DVI-2 and 4 injection, respectively. Also the test was carried out varying the steam flow rate greatly to investigate the effect of steam flow rate on the direct bypass fraction of ECC water. Test results show that the direct bypass fraction of ECC water depends significantly on the injected steam mass flow rate. DVI-4 tests show that the direct bypass fraction increases drastically as the steam flow rate increases. However, in DVI-2 test most of the injected ECC water penetrates into lower downcomer. The direct bypass characteristic in each of DVI-2 and DVI-4 tests is reflected into the direct bypass characteristic curve of DVI-2 and 4 test. The steam condensation reaches to the theoretically allowable maximum value

  14. Experimental results of the SMART ECC injection performance with reduced scale of test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Shin, Yong Cheol; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    SMART pressurized water reactor type is different from the existing integral NSSS commercial pressurized water reactor system which is equipped with the main features. In addition, RCS piping is removed and the feature of the SBLOCA is a major design break accident. SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) test facility is to simulate the 2 inch SBLOCA of the SMART using with reduced scale. The Test was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this paper, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  15. Quick Look Report of the SMART ECC injection performance test I3

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    The objective of this report is to describe test results of the Test I3 simulating the 2 inch SBLOCA of the SMART using the SWAT test facility. The Test I3 was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this report, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  16. Emergency response guide-B ECCS guideline evaluation analyses for N reactor

    International Nuclear Information System (INIS)

    Chapman, J.C.; Callow, R.A.

    1989-07-01

    INEL conducted two ECCS analyses for Westinghouse Hanford. Both analyses will assist in the evaluation of proposed changes to the N Reactor Emergency Response Guide-B (ERG-B) Emergency Core System (ECCS) guideline. The analyses were a sensitivity study for reduced-ECCS flow rates and a mechanistically determined confinement steam source for a delayed-ECCS LOCA sequence. The reduced-ECCS sensitivity study established the maximum allowable reduction in ECCS flow as a function of time after core refill for a large break loss-of-coolant accident (LOCA) sequence in the N Reactor. The maximum allowable ECCS flow reduction is defined as the maximum flow reduction for which ECCS continues to provide adequate core cooling. The delayed-ECCS analysis established the liquid and steam break flows and enthalpies during the reflood of a hot core following a delayed ECCS injection LOCA sequence. A simulation of a large, hot leg manifold break with a seven-minute ECCS injection delay was used as a representative LOCA sequence. Both analyses were perform using the RELAP5/MOD2.5 transient computer code. 13 refs., 17 figs., 3 tabs

  17. Advanced DVI for ECC direct bypass mitigation

    International Nuclear Information System (INIS)

    Kwon, Tae-Soon; Song, Chul-Hwa; Baek, Won-Pil

    2009-01-01

    An ECC direct bypass fraction during a late reflood phase of a LBLOCA is strongly dependent on the characteristics of the cross flow and the geometrical configuration of a DVI in the downcomer of a pressurized light water reactor. The important design parameters of a DVI are the elevation, the azimuthal angle, and the separator to prevent a steam-water interaction. An ECC sub-channel to separate or to isolate an ECC water from a high-speed cross flow is one of the important design features to mitigate the ECC bypass phenomena. A dual core barrel cylinder as an ECC flow separator is located between a reactor vessel and a core barrel outer wall in the downcomer annulus. A new narrow gap between the core barrel and the additional dual core barrel plays the role of a downward ECC flow channel or an ECC flow separator in a high-speed cross flow field of the downcomer annulus. The flow zone around a broken cold leg in the downcomer annulus has the role of a high ECC direct bypass due to a strong suction force while the wake zone of a hot leg has the role of an ECC penetration. Thus, the relative azimuthal angle of the DVI nozzle from the broken cold leg is an important design parameter. A large azimuthal angle from a cold leg to a hot leg needs to avoid a high suction flow zone when an ECC water is being injected. The other enhancing mechanism of an ECC penetration is a grooved core barrel which has small rectangular-shaped grooves vertically arranged on the core barrel wall of the reactor vessel downcomer annulus. These grooves have the role for a generation of a vortex induced by a high-speed cross flow. Since the stagnant flow in a lateral direction and rotational vortex provides the pulling force of an ECC drop or film to flow down into the lower downcomer annulus by gravity, the ECC direct bypass fraction is reduced when compared to the current design of a smoothed wall. An open channel of grooves generates a stagnant vortex, while a closed channel of grooves

  18. Method and device for controlling ECCS

    International Nuclear Information System (INIS)

    Ikeda, Takashi; Kataoka, Yoshiyuki; Murase, Michio.

    1986-01-01

    Purpose: To accomplish reactor cooling without exposing fuel assemblies out of the coolant and also without inducing counter-current flow (CCFL) brake likely to be caused by excess injection of water even in case of malfunction of one system in a loss-of-coolant accident. Method: In a BWR type reactor having more than two independent ECCS, the lower plenum water level is measured and when the lower plenum is full of water, the ECCS are kept in a fully closed state, and reversely when the lower plenum is not full of water, more coolant than the lost quantity of water will be injected into the plenum at a higher pressure than a pressure at which fuel rods just begin to be exposed to the steam phase. The subcool energy of the emergency coolant to be injected is determined by the decay heat of the core and the change rate of a container pressure. However, the quantity of the emergency coolant is controlled such that the subcool energy will always become less than the overheating energy in the core range and the lower plenum range, thus improving safety and enabling the removal of a prior-art ECCS. (Kamimura, M.)

  19. Effects of high temperature ECC injection on small and large break BWR LOCA simulation tests in ROSA-III program (RUNs 940 and 941)

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Nakamura, Hideo; Kumamaru, Hiroshige; Anoda, Yoshinari; Yonomoto, Taisuke; Murata, Hideo; Tasaka, Kanji

    1990-03-01

    The ROSA-III program, of which principal results are summarized in a report of JAERI 1307, conducted small and large-break loss-of-coolant experiments (RUNs 940 and 941) with high water temperature of the emergency core cooling system (ECCS) are one of the parametric study with respect to the ECCS effect on core cooling. This report presents all the experiment results of these two tests and describes additional finding with respect to the hot ECC effects on core cooling phenomena. By comparing these two tests (water temperature of 393 K) with the standard ECC tests of RUNs 922 and 926 (water temperature of 313 K), it was found that the ECC subcooling variation had a small influence on the core cooling phenomena in 5 % small break tests but had larger influence on them in 200 % break tests. The ECC subcooling effects described in the previous report are reviewed and the temperature distribution in the pressure vessel is investigated for these four tests. (author)

  20. Water-hammer in the cold leg during an SBLOCA due to cold ECCS injection

    International Nuclear Information System (INIS)

    Ortiz, M.G.; Ghan, L.S.

    1991-01-01

    Water-hammer might occur in the cold leg of pressurized water reactors (PWR) during small break loss-of-coolant accidents (SBLOCA's), when cold emergency core cooling system (ECCS) water is injected into a pipe that may be partially filled with saturated steam. The water may mix with the steam and cause it to condense abruptly. Depending on the flow regime present, slugs of liquid may then be accelerated towards each other or against the piping structure. The possibility of this phenomenon is of concern to us because it may become a dominant phenomenon and change the character of the transient. In performing the code scaling, applicability, and uncertainty study (CSAU) on a SBLOCA scenario, we had to examine the possibility that the transient being analyzed could experience water-hammer and thus depart from the scope of the study. Two criteria for water-hammer initiation were investigated and tested using a RELAP5/MOD3 simulation of the transient. Our results indicated a very low likelihood of occurrence of the phenomenon. 8 refs., 6 figs

  1. Pressure vessel fracture studies pertaining to a PWR LOCA-ECC thermal shock: experiments TSE-1 and TSE-2

    International Nuclear Information System (INIS)

    Cheverton, R.D.

    1976-09-01

    The LOCA-ECC Thermal Shock Program was established to investigate the potential for flaw propagation in pressurized-water reactor (PWR) vessels during injection of emergency core coolant following a loss-of-coolant accident. Studies thus far have included fracture mechanics analyses of typical PWRs, the design and construction of a thermal shock test facility, determination of material properties for test specimens, and two thermal shock experiments with 0.53-m-OD (21-in.) by 0.15-m-wall (6-in.) cylindrical test specimens. The PWR calculations indicated that under some circumstances crack propagation could be expected and that experiments should be conducted for cracks that would have the potential for propagation at least halfway through the wall

  2. Safety evaluation report on Westinghouse Electric Company ECCS evaluation model for plants equipped with upper head injection

    International Nuclear Information System (INIS)

    Lauben, G.N.; Wagner, N.H.; Israel, S.L.; McPherson, G.D.; Hodges, M.W.

    1978-04-01

    For plants which include an ice condenser containment concept, Westinghouse has planned an additional safety system known as the upper head injection (UHI) system to augment the emergency core cooling system. This system is comprised of additional accumulator tanks and piping arranged to supply cooling water to the top of the core during the blowdown period following a postulated large-break loss-of-coolant accident (LOCA). The objective of UHI is to add to the core cooling provided by the conventional emergency core cooling system (ECCS) and so permit operation at linear heat rates comparable to those permitted in plants utilizing the dry containment concept. In this way, plants which include the UHI system would have greater operating flexibility while still meeting the acceptance criteria as defined in paragraph 50.46 of 10 CFR Part 50. This review is concerned with those changes to the Westinghouse ECCS evaluation model that have been proposed for the UHI-LOCA model

  3. A study of ECC water bypass reduction technology for an improvement of core cooling capability

    International Nuclear Information System (INIS)

    Song, C. G.; Kwon, T. S.; Yun, B. J.

    2006-02-01

    The research for the reduction of ECC water bypass fraction was mainly performed to develop the flow mechanisms that ECC water can penetrate more effectively into a lower downcomer. Evaluation were carried out for the effect of major parameters on the bypass of ECC water in the downcomer with DVI. The following various physical models were derived for the reduction of the bypass fraction of ECC water: models of changing DVI injection angle, models of rearranging relative angles of DVI nozzles, model of grooved-and-subchannel type core barrel, model of dual core barrel. CFD analysis and MARS design verification were performed for the derived models as a first step performance estimation. Through out air-water verification experiments, quantitative evaluation were performed for each model, and three most efficient models were suggested. Examination were carried out for the requirement of structural modification and the change in structural integrity due to the adoption of one of the schemes

  4. ECCS Operability With One or More Subsystem(s) Inoperable

    International Nuclear Information System (INIS)

    Swantner, Stephen R.; Andrachek, James D.

    2002-01-01

    Plant Technical Specifications are issued by the US NRC to ensure that safe nuclear power plant operation is maintained within the assumptions for parameters and Structures, Systems, and Components (SSCs) made in the plant safety analysis reports. The Technical Specifications are made up of Limiting Conditions for Operation (LCOs), which are the minimum set of requirements that must be met based on the assumptions of the safety analysis, Actions, which are the remedial or compensatory actions that must be taken if the LCO is not met, and Surveillance Requirements, that demonstrate that the LCO is met. The Technical Specification Actions contain Completion Times (CTs) which are the time within which remedial actions must be taken, in the event that the LCO is not met. The Improved Standard Technical Specifications (ISTS) for Westinghouse plants are contained in NUREG-1431, Revision 2. Condition A of Technical Specification 3.5.2 (ECCS- Operating) in NUREG-1431, Revision 2, allows components to be taken out of service for up to 72 hours, as long as 100% of the ECCS flow equivalent to a single Operable ECCS train exists. Condition A would allow, for example, the A train low head safety injection (LHSI) and the B train high head safety injection (HHSI) pumps to be taken out of service (for 72 hours) as long as it could be demonstrated that the remaining components could provide 100% train equivalent flow capacity. The 'cross-training' allowed by this Condition in the ISTS provides flexibility when performing routine pre-planned preventive maintenance and testing, as well as during emergent corrective maintenance and testing associated with random component inoperabilities. Without this flexibility, a unit would have to initiate a plant shutdown within 1 hour, if component(s) were inoperable in different trains. In order to implement this flexibility, the various combinations of components in opposite trains must be evaluated to determine whether 100% of the ECCS flow

  5. Development of Calculation Algorithm for ECCS Kinematic Shock

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Chan; Yoon, Duk-Joo; Ha, Sang-Jun [KHNP-CRI, Daejeon (Korea, Republic of)

    2014-10-15

    The void fraction of inverted U-pipes in front of SI(Safety Injection) pumps impact on the pipe system of ECCS(Emergency Core Cooling Systems). This phenomena is called as 'Kinematic Shock'. The purpose of this paper is to achieve the more exactly calculation when the kinematic shock is calculated by simplified equation. The behavior of the void packet of the ECCS pipes is illustrated by the simplified (other name is kinematic shock equation).. The kinematic shock is defined as the depth of total length of void clusters in the pipes of ECCS when the void cluster is continually reached along the part of pipes in vertical direction. In this paper, the simplified equation is evaluated by comparing calculation error each other.]. The more exact methods of calculating the depth of the kinematic shock in ECCS is achieved. The error of kinematic shock calculation is strongly depended on the calculation search gap and the order of Taylor's expansion. From this study, to select the suitable search gap and the suitable calculation order, differential root method, secant method, and Taylor's expansion form are compared one another.

  6. Experiment data report for semiscale Mod-1 test S-04-1 (baseline ECC test)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Collins, B.L.; Sackett, K.E.

    1976-09-01

    Recorded test data are presented for Test S-04-1 of the Semiscale Mod-1 Baseline ECC Test Series. This test is among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor system. Test S-04-1 was conducted from an initial cold leg fluid temperature of 542 0 F and an initial pressure of 2,263 psia. A simulated double-ended offset shear cold leg break was used to investigate the system response to a depressurization and reflood transient using system volume scaled coolant injection parameters. System flow was set to achieve a core fluid temperature differential of 66 0 F at a full core power of 1.6 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a flat radial power profile was used in the pressure vessel to simulate the effects of a nuclear core. During system depressurization, core power was reduced from the initial level of 1.6 MW in such a manner as to simulate the surface heat flux response of nuclear fuel rods until such time that departure from nucleate boiling might occur. Blowdown to the pressure suppression system was accompanied by simulated emergency core cooling injection into both the intact and broken loops. Coolant injection was continued until test termination at 200 seconds after initiation of blowdown

  7. Design Development of SMART ECC Water Asymmetric Two-phase choking test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Shin, Yong Cheol; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    SMART pressurized water reactor type is different from the existing integral NSSS commercial pressurized water reactor system which is equipped with the main features. In addition RCS piping is removed and the feature of the SBLOCA is a major design break accident. The TASS / SMR code is analyzed SMART SBLOCA. In order to verify analysis code, SMART analysis for verification of conservatism is promoting using data for experiments with Integral Effect Test and Separate Effect. In this paper, the design feature of the SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) is described. SWAT is linearly reduced to a 1/5 ratio while the geometrical shape is conserved. In major shape of SMART ECC injection performance test, distortions which caused by gravitational effects are minimized. Because both the emergency core cooling water injection nozzle height and the break nozzle height match the RCP Suction Nozzle height in test section of the main forms. The main part of the test section is SG-side upper down-comer. The boundary conditions are saturated steam and water flow condition and drain flow rate to control the collapsed water level in the down-comer

  8. Experiment data report for Semiscale Mod-1 Test S-05-4 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Feldman, E.M.

    1977-03-01

    Recorded test data are presented for Test S-05-4 of the Semiscale Mod-1 alternate emergency core coolant injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-4 was conducted from initial conditions of 2266 psia and 543 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of each loop and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. The upper plenum coolant injection was scaled according to the heat stored in the metal mass of the upper plenum

  9. Evaluation of ECC bypass data with a nonlinear constrained MLE technique

    International Nuclear Information System (INIS)

    Bishop, T.A.; Collier, R.P.; Kurth, R.E.

    1980-01-01

    Recently, Battelle's Columbus Laboratories have been involved in scale-model tests of emergency core cooling (ECC) systems for hypothesized loss-of-coolant accidents in pressurized water reactors (PWR). These tests are intended to increase our understanding of ECC bypass, which can occur when steam flow from the reactor core causes the emergency coolant to bypass the core and flow directly to the break. One objective of these experiments is the development of a correlation which relates the flow rate of water penetrating to the core to the steam flow rate. This correlation is derived from data obtained from a 2/15 scale model PWR at various ECC water injection rates, subcoolings, pressures, and steam flows. The general form of the correlation being studied is a modification of the correlation first proposed by Wallis. The correlation model is inherently nonlinear and implicit in form, and the model variables are all subject to error. Therefore, the usual nonlinear analysis techniques are inappropriate. A nonlinear constrained maximum-likelihood-estimation technique has been used to obtain estimates of the model parameters, and a Battelle-developed code, NLINMLE, has been used to analyze the data. The application of this technique is illustrated by sample calculations of estimates of the model parameters and their associated confidence intervals for selected experimental data sets. 5 figures, 7 tables

  10. The Heat Exchanger for Passive Part ECCS of WWER-1000 on Base of the Thermo siphons

    International Nuclear Information System (INIS)

    Kirov, V.; Chulkin, O.

    2008-01-01

    One of NPP's systems providing safe operation is the system of emergency core cooling system (ECCS), which primary function in accidents is to flood the nuclear reactor core and to assure the sub critical condition and core cooling. At injection of cold water in reactor thermal stresses and thermal fatigue in the vessel cladding and constructional materials are arise. Low temperature of the water injected in reactor is a reason of occurrence of these undesirable consequences. Some variants of the water heating in accumulators of ECCS are considered. Now at Ukrainian NPPs the electrical heating in accumulators is used. Electrical heaters create the essential additional loading to diesel generators at imposing of two accidents - the large break and losses of power supplies on own needs. It is offered to use a heater in accumulators that working by a principle two-phase thermal siphon which advantages is: small dimensions, small delay and design reliability. In such heat exchanger the heating medium is a direct steam and the heated up medium is water with boric acid from accumulators of ECCS. Under requirements of the service regulations of ECCS accumulators it is necessary to guarantee injected water heating up to 90 ?? in case of a small break and to 150 ?? in case of the large break. Results of calculations for different external diameters of a tube of thermal siphon which have allowed to define the constructive sizes of heat exchanger, providing necessary conditions for required functioning of passive part ECCS are submitted The calculation and analysis of operating modes of the changed circuit of passive part ECCS for various accidents is carried out. The calculated pressure drop indicates that changes do not have essential influence on system work as a whole. Thus, the submitted decision provides the increase of reliability of ECCS at small and large breaks accidents, i.e. in all modes stipulated by the project.(author)

  11. Safety verification for the ECCS driven by the electrically 4 trains during LBLOCA reflood phase using ATLAS

    International Nuclear Information System (INIS)

    Park, Yusun; Park, Hyun-sik; Kang, Kyoung-ho; Choi, Nam-hyun; Min, Kyoung-ho; Choi, Ki-yong

    2014-01-01

    Highlights: • Safety improvement by adopting 4 train emergency core cooling system was validated experimentally. • General thermal hydraulic behaviors of the system during LBLOCA reflood phase were successfully demonstrated. • Key parameters such as the liquid levels, the PCTs, the quenching time, and the ECC bypass ratios were investigated. • Asymmetric effects of the different combination of safety injection were negligible during the reflood period. - Abstract: The APR1400 is equipped with four safety injection pumps driven by two emergency diesel generators. However, the design has been changed so that the four safety injection pumps are driven by 4 emergency diesel generators during the design certification process from the U.S. NRC. Thus, 4 safety injection pumps (SIPs) are completely independent electrically and mechanically and three safety injection pumps are available in a single failure condition. This design change could have a certain effects on the thermal-hydraulic phenomenon occurring in the downcomer region during the late reflood phase of a large break loss of coolant accident (LBLOCA). Thus, in this study, a verification experiment for the reflood phase of a LBLOCA was performed to evaluate the core cooling performance of the 4 train emergency core cooling system (ECCS) with an assumption of a single failure. And the different combinations of three SIPs positions were tested to investigate the asymmetric effects on the reactor core cooling performance. The overall experimental results revealed the typical thermal–hydraulic trends expected to occur during the reflood phase of a large-break LOCA scenario for the APR1400. Experiment with the injection of three SIPs showed a faster core quenching time and lower bypass ratio than that of the case in which two SIPs were injected. The RPV wall temperature distributions showed the similar trend in spite of the different SIP combinations

  12. LOFT ECC Pitot Tube and Thermocouple Rake Penetration thermal analysis

    International Nuclear Information System (INIS)

    Tolan, B.J.

    1977-01-01

    A thermal analysis of the LOFT ECC Pitot Tube and Thermocouple Rake Penetration was performed using COUPLE, a two-dimensional finite element computer code. Four transients which conservatively cover all transients the rake will be exposed to were included in this analysis in order to comply with the ASME Code Section III requirements. The transients conservatively cover hot and cold leg operation, and nuclear and nonnuclear operation. The four transients include the LOCE with ECC injection transient, the single control rod drop transient, the scram transient, and the heatup with 0 to 100% load change transient. Temperature distributions in the rake were obtained for each of the four transients and several plots of node temperatures vs. time are given

  13. Experiment data report for semiscale Mod-1 test S-04-2 (baseline ECC test)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Collins, B.L.; Sackett, K.E.

    1976-09-01

    Recorded test data are presented for Test S-04-2 of the Semiscale Mod-1 Baseline ECC test series. This test is among Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor system. Test S-04-2 was conducted from an initial cold leg fluid temperature of 542 0 F and an initial pressure of 2,263 psia. A simulated double-ended offset shear cold leg break was used to investigate the system response to a depressurization and reflood transient using emergency core coolant injection parameters based on downcomer volume scaling. System flow was set to achieve a core fluid temperature differential of 66 0 F at a full core power of 1.6 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a flat radial power profile was used in the pressure vessel to simulate the effects of a nuclear core. During system depressurization, core power was reduced from the initial level of 1.6 MW to simulate the surface heat flux response of nuclear fuel rods until such sime that departure from nucleate boiling might occur. Blowdown to the pressure suppression system was accompanied by simulated emergency core coolant injection into both the intact and broken loops. Coolant injection was continued until test termination at 200 seconds after initiation of blowdown. The purpose of the report is to make available the uninterpreted data from Test S-04-2 for future data analysis and test results reporting activities. The data, presented in the form of graphs in engineering units, have been analyzed only to the extent necessary to assure that they are reasonable and consistent

  14. Method of controlling ECCS system in reactors

    International Nuclear Information System (INIS)

    Oohashi, Hideaki; Ikehara, Morihiko.

    1982-01-01

    Purpose: To eliminate the risk of misoperation and thereby improve the reliability of ECCS system upon accident. Method: ECCS system for nuclear reactor is automatically started by either of signals from a water level detector in a pressure vessel or from a pressure detector in a reactor container. Further, the ECCS system is started or stopped by the manual operation irrespective of the signals, and the signals from the pressure detector are isolated from the ECCS-starting signal by the contacts which actuate interlocked with the stopping operation of the manual operation switch. Then, after stopping the ECCS system by the manual operation, the ECCS system is started by the signals from the water level detector irrespective of the signals from the pressure detector. (Seki, T.)

  15. Pressure vessel fracture studies pertaining to a PWR LOCA-ECC thermal shock: experiments TSE-3 and TSE-4 and update of TSE-1 and TSE-2 analysis

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Bolt, S.E.

    1977-01-01

    The LOCA-ECC Thermal Shock Program was established to investigate the potential for flaw propagation in pressurized-water reactor (PWR) vessels during injection of emergency core coolant following a loss-of-coolant accident. Studies thus far have included fracture mechanics analyses of typical PWRs, the design and construction of a thermal shock test facility, determination of material properties for test specimens, and four thermal shock experiments with 0.53-m-OD (21-in.) by 0.15-m-wall (6-in.) cylindrical test specimens. In the first experiment, initiation was not expected and did not occur, although there was a small amount of subcritical crack growth. In the second experiment, initiation of a semicircular flaw took place as expected; the final length along the surface was about four times the initial length, but there was no radial growth. The third and fourth experiments were similar, and the long axial flaw initiated in good agreement with predictions

  16. Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS

    International Nuclear Information System (INIS)

    Hanson, G.H.

    1978-01-01

    The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. A policy involves disabling the automatic-actuation of the LOFT ECCS, but still retaining the manual actuation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 33 kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS. For the operating power of the L2-2 Experiment, the required decay-periods (with operating periods of 40 and 2000 hours) are about 21 and 389 hours, respectively. With operating periods of 40 and 2000 hours at Core-I full power, the required decay-periods are about 42 and 973 hours, respectively. After these decay periods the automatic actuation of the LOFT ECCS can be disabled assuming a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS. The automatic and manual lineup of the ECCS may be waived if decay power is less than 11 kW

  17. Prediction of ROSA-III experiment

    International Nuclear Information System (INIS)

    Soda, Kunihisa

    1978-06-01

    ROSA-III experiment with the simulated BWR system is to investigate thermal hydraulic behavior as well as ECCS performance in a postulated loss-of-coolant accident. RUN 701 assumes average core power, high and low pressure core sprays and low pressure injection of ECCS. Prediction of experiment RUN 701 was made with computer code RELAP-4J. The results indicate the need for ROSA-III pump characteristics to be clarified and for liquid level formation model to be improved. Comparison of the prediction results with the experimental data should reveal the areas of modifications in calculation model. (auth.)

  18. On the energy shift the ECC cusp. Does the shift really exist?

    International Nuclear Information System (INIS)

    Sarkadi, L.; Barrachina, R.O.

    2004-01-01

    The cusplike 'electron capture to the continuum' (ECC) peak appearing in the spectrum of the forward emitted electrons in ion-atom collisions are generally thought to be a divergence. Recently Shah et al., however, claimed that 'the ECC cusp is indeed a cusp, and not a divergence smoothed by the experiment'. These authors measured the ECC cusp for collisions of 10- and 20-keV protons with H 2 and He, and found that the peak was shifted to lower velocity than its expected position. We also carried out CTMC calculations (for the case of 20-keV protons on He) by which we demonstrated that the shift really exists but its value depends on the angular window of the electron detection. (K.A.)

  19. Historical information on ORNL proposals for ECCS testing

    International Nuclear Information System (INIS)

    1976-01-01

    This document contains a compilation of the correspondence and preliminary report which the Oak Ridge National Laboratory submitted to the U.S. Atomic Energy Commission on the subject of in situ testing of emergency core cooling systems (ECCS) in pressurized water reactors. Most of the correspondence, which was prepared four to five years ago, deals with an ORNL proposal to evaluate the merits of conducting an in situ ECCS test in a full-scale commercial power plant. The end result of this work was to be a report in which the feasibility of conducting such an experiment would be discussed and a ''rough'' cost estimate provided. In support of this proposal, ORNL prepared a brief preliminary prospectus which identified some of the key questions that were to be addressed should the evaluation study be funded

  20. Two-phase flow dynamics in ECC

    International Nuclear Information System (INIS)

    Albraaten, P.J.

    1981-07-01

    The present report summarizes the achievements within the project ''Two-phase Systems and ECC''. The results during 1978 - 1980 are accounted for in brief as they have been documented in earlier reports. The results during the first half of 1981 are accounted for in greater detail. They contain a new model for the Basset force and test runs with this model using the test code RISQUE. Furthermore, test runs have been performed with TRAC-PD2 MOD 1. This code was implemented on Edwards Pipe Blowdown experiment (a standard test case) and UC-Berkeley Reflooding experiment (a non-standard test case.) (Auth.)

  1. Scaling and design report of ECC performance test facility (SWAT) of SMART

    International Nuclear Information System (INIS)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Shin Yong Chul; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae

    2010-12-01

    SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) was designed by 1/5 scaling ratio using the modified linear scaling method. The design characteristics of the SMART such that the elevation of RCP suction nozzles is the same with that of the ECC injection nozzles are maintained to reduce a distortion caused by the gravitational effect. Thermal hydraulic phenomena in a test facility designed by the modified linear scaling method can be simulated more accurately than those by the full-height and reduced area scaling method. The main part of the test section is SG-side upper down-comer. The boundary conditions are saturated steam and water flow condition and drain flow rate to control the collapsed water level in the down-comer. The test data of the SWAT can produce the well-defined boundary condition to validate the thermal hydraulic analysis code for the SMART

  2. Scaling and design report of ECC performance test facility (SWAT) of SMART

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Shin Yong Chul; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) was designed by 1/5 scaling ratio using the modified linear scaling method. The design characteristics of the SMART such that the elevation of RCP suction nozzles is the same with that of the ECC injection nozzles are maintained to reduce a distortion caused by the gravitational effect. Thermal hydraulic phenomena in a test facility designed by the modified linear scaling method can be simulated more accurately than those by the full-height and reduced area scaling method. The main part of the test section is SG-side upper down-comer. The boundary conditions are saturated steam and water flow condition and drain flow rate to control the collapsed water level in the down-comer. The test data of the SWAT can produce the well-defined boundary condition to validate the thermal hydraulic analysis code for the SMART

  3. Shear behavior of reinforced Engineered Cementitious Composites (ECC) beams

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2010-01-01

    This paper describes an experimental investigation of the shear behavior of beams consisting of steel reinforced Engineered Cementitious Composites (ECC). Based on the strain hardening and multiple cracking behavior of ECC, this study investigates the extent to which ECC can improve the shear...... capacity of beams loaded primarily in shear and if ECC can partially or fully replace the conventional transverse steel reinforcement in beams. However, there is a lack of understanding of how the fibers affect the shear carrying capacity and deformation behavior of structural members if used either...

  4. Thermal shock studies associated with injection of emergency core coolant in pressurized water reactors

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Bolt, S.E.; Iskander, S.K.

    1977-01-01

    Studies to determine the accuracy of calculational techniques for predicting crack initiation and arrest in PWR vessels due to thermal shock from ECC injection are described. The reference calculational model is reviewed, the experimental program and facilities are described, and some thermal shock experiments and results are discussed

  5. Multi-dimensional analysis of the ECC behavior in the UPI plant Kori Unit 1

    International Nuclear Information System (INIS)

    Bae, Sungwon; Chung, Bub-Dong; Bang, Young Seok

    2008-01-01

    A multi-dimensional transient analysis during the LBLOCA of the Kori Unit 1 has been performed by using the MARS code. Based on 1-D nodalization of the Kori Unit 1, the reactor vessel nodalizations have been replaced by the multi-dimensional component. The multi-dimensional component for the reactor vessel is designed as 5 radial, 8 peripheral, and 21 vertical grids. It is assumed that the fuel assemblies are homogeneously distributed in inner 3 radial grids. The outer 1 radial grid region is modeled as the core bypass. The outer-model 1 radial grid is used for the downcomer region. The corresponding heat structures and fuels are modified to fit for the multi-dimensional reactor vessel model. The form drag coefficients for the upper plenum and the core have been designated as 0.6 and 9.39, respectively. The form drag coefficients for the radial and peripheral directions are assigned to the same on the assumption of homogeneous distribution of the flow obstacles. After obtaining the 102% power steady operation condition, cold leg LOCA simulation is performed during 400 second period. The multi-dimensional steady run results show no severe differences compared to the traditional 1-D nodalization results. After the ECC injection starts, a liquid pool is maintained at the upper plenum because the ECCS water can not overcome the upward gas flow that comes from the reactor core through the upper tie plate. The depth of ECCS water pool is predicted as about 20% of the total height from the upper tie plate and the center line of the hot leg pipe. At the vicinity region of the active ECCS show higher depth of liquid pool. The accumulated water flow rate passing the upper tie plate is calculated by the transient result. Much downward water flow is obtained at the outer-most region of upper plenum space. The downward flow dominant region is about 32.3% of the total upper tie plate area. The accumulated ECCS bypass ratio is predicted as 27.64% at 300 second. It is calculated

  6. The microstructure of self-healed PVA ECC under wet and dry cycles

    Directory of Open Access Journals (Sweden)

    Jia Huan Yu

    2010-06-01

    Full Text Available Self-healing of ECC (Engineered Cementitious Composites subjected to cyclic wetting and drying regimes is investigated in this paper. ECC structures subjected to outdoor environmental conditions such as wind and rain runoff can be simulated by accelerated test method of wetting and drying cycles. Uniaxial tensile tests of ECC M45 and ECC 2.8FA specimen are conducted respectively. It is found that crack width of ECC 2.8FA is around 10 μm with increased amount of fly ash, while the crack width of ECC M45 is around 100 μm. New insights about the microstructure and chemical composition analysis of ECC specimens initially cracked to 2% strain and then self-healed under wet-dry cycles are presented.

  7. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  8. Assessment of human effective absorbed dose of 67 Ga-ECC based on biodistribution rat data.

    Science.gov (United States)

    Shanehsazzadeh, Saeed; Yousefnia, Hassan; Lahooti, Afsaneh; Zolghadri, Samaneh; Jalilian, Amir Reza; Afarideh, Hossien

    2015-02-01

    In a diagnostic context, determination of absorbed dose is required before the introduction of a new radiopharmaceutical to the market to obtain marketing authorization from the relevant agencies. In this work, the absorbed dose of [67 Ga]-ethylenecysteamine cysteine [(67 Ga)ECC] to human organs was determined by using distribution data for rats. For biodistribution data, the animals were sacrificed by CO2 asphyxiation at selected times after injection (0.5, 2 and 48 h, n = 3 for each time interval), then the tissue (blood, heart, lung, brain, intestine, feces, skin, stomach, kidneys, liver, muscle and bone) were removed. The absorbed dose was determined by Medical Internal Radiation Dose (MIRD) method after calculating cumulated activities in each organ. Our prediction shows that a 185-MBq injection of (67)Ga-ECC into the humans might result in an estimated absorbed dose of 0.029 mGy in the whole body. The highest absorbed doses are observed in the spleen and liver with 33.766 and 16.847 mGy, respectively. The results show that this radiopharmaceutical can be a good SPECT tracer since it can be produced easily and also the absorbed dose in each organ is less than permitted absorbed dose.

  9. Heat and mass transfer in the stratified flow with ECCS injection

    International Nuclear Information System (INIS)

    Strubelj, L.; Tiselj, I.

    2007-01-01

    One of the most important problems in the light-water nuclear thermal-hydraulics is behaviour of the cold emergency core cooling water injected from the top or from the bottom into the horizontal section of the cold leg near the reactor vessel during the loss of coolant accident. The stratified flows appear where cold water is injected in partially or fully uncovered horizontal cold leg. The hot steam condenses on cold water surface what is also called direct contact condensation. Direct contact condensation and condensation induced water-hammer in a horizontal pipe were experimentally investigated at PMK-2 test facility of the Hungarian Atomic Energy Research Institute KFKI. The cold water is injected through small pipe into lower horizontal part of the section, and then water fills the vertical pipeline and floods the horizontal test section of the pipeline of the PMK-2 integral test facility. As liquid water floods the horizontal part of the pipeline, the counter current horizontally stratified flow is being observed. During the flooding of the pipeline, the steam-liquid interface area increases and therefore the steam condensation rate and the steam velocity also increase and can lead to bubble entrapment. Water level at one cross-section and four local void fraction and temperature at the top of horizontal test pipeline was measured and compared with simulation. Condensed steam increases the water temperature that is why the local temperature measurements are the most important information, from which condensation rate can be estimated, since mass of condensed steam was not measured. Numerical simulation of the experiment with thermal phase change is presented. Surface renewal concept with small eddies is used for calculation of condensation heat transfer coefficient. Two simulations were performed: simulation of whole experimental domain (lower horizontal, vertical and test horizontal pipeline) and simplified simulation of only upper horizontal test section

  10. Evaluation of mispositioned ECCS valves

    International Nuclear Information System (INIS)

    Hill, R.A.; O'Brien, J.F.; McIntire, D.C.; Barlow, R.T.

    1977-09-01

    In October of 1975, Westinghouse submitted NS-CE-787, dated October 17, 1975, to the Nuclear Regulatory Commission (NRC) and entered into discussions with them concerning the spurious movement of certain motor-operated valves (MOV's) in the Emergency Core Cooling System (ECCS) to a position defeating the ECCS function at a time when this function is required. On November 25, 1975, the discussion turned to the possible movement of a manually controlled, motor-operated valve due to a fault in its electrical circuitry and the NRC staff expressed concerns about other possible failure modes that might lead to such a valve movement. The NRC meeting minutes document these concerns. This report is an item-by-item response to the concerns expressed by the NRC staff at that meeting and incorporates the original electrical fault analysis

  11. Direct vessel inclined injection system for reduction of emergency core coolant direct bypass in advanced reactors

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Lee, Jong G.; Suh, Kune Y.

    2006-01-01

    Multidimensional thermal hydraulics in the APR1400 (Advanced Power Reactor 1400 MWe) downcomer during a large-break loss-of-coolant accident (LBLOCA) plays a pivotal role in determining the capability of the safety injection system. APR1400 adopts the direct vessel injection (DVI) method for more effective core penetration of the emergency core cooling (ECC) water than the cold leg injection (CLI) method in the OPR1000 (Optimized Power Reactor 1000 MWe). The DVI method turned out to be prone to occasionally lack in efficacious delivery of ECC to the reactor core during the reflood phase of a LBLOCA, however. This study intends to demonstrate a direct vessel inclined injection (DVII) method, one of various ideas with which to maximize the ECC core penetration and to minimize the direct bypass through the break during the reflood phase of a LBLOCA. The 1/7 scaled down THETA (Transient Hydrodynamics Engineering Test Apparatus) tests show that a vertical inclined nozzle angle of the DVII system increases the downward momentum of the injected ECC water by reducing the degree of impingement on the reactor downcomer, whereby lessening the extent of the direct bypass through the break. The proposed method may be combined with other innovative measures with which to ensure an enough thermal margin in the core during the course of a LBLOCA in APR1400

  12. Energy-dissipating and self-repairing SMA-ECC composite material system

    International Nuclear Information System (INIS)

    Li, Xiaopeng; Li, Mo; Song, Gangbing

    2015-01-01

    Structural component ductility and energy dissipation capacity are crucial factors for achieving reinforced concrete structures more resistant to dynamic loading such as earthquakes. Furthermore, limiting post-event residual damage and deformation allows for immediate re-operation or minimal repairs. These desirable characteristics for structural ‘resilience’, however, present significant challenges due to the brittle nature of concrete, its deformation incompatibility with ductile steel, and the plastic yielding of steel reinforcement. Here, we developed a new composite material system that integrates the unique ductile feature of engineered cementitious composites (ECC) with superelastic shape memory alloy (SMA). In contrast to steel reinforced concrete (RC) and SMA reinforced concrete (SMA-RC), the SMA-ECC beams studied in this research exhibited extraordinary energy dissipation capacity, minimal residual deformation, and full self-recovery of damage under cyclic flexural loading. We found that the tensile strain capacity of ECC, tailored up to 5.5% in this study, allows it to work compatibly with superelastic SMA. Furthermore, the distributed microcracking damage mechanism in ECC is critical for sufficient and reliable recovery of damage upon unloading. This research demonstrates the potential of SMA-ECC for improving resilience of concrete structures under extreme hazard events. (paper)

  13. Design process of the nanofluid injection mechanism in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Bang In Choel

    2011-01-01

    Full Text Available Abstract Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs. This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner.

  14. Preliminary Evaluation Methodology of ECCS Performance for Design Basis LOCA Redefinition

    International Nuclear Information System (INIS)

    Kang, Dong Gu; Ahn, Seung Hoon; Seul, Kwang Won

    2010-01-01

    To improve their existing regulations, the USNRC has made efforts to develop the risk-informed and performance-based regulation (RIPBR) approaches. As a part of these efforts, the rule revision of 10CFR50.46 (ECCS Acceptance Criteria) is underway, considering some options for 4 categories of spectrum of break sizes, ECCS functional reliability, ECCS evaluation model, and ECCS acceptance criteria. Since the potential for safety benefits and unnecessary burden reduction from design basis LOCA redefinition is high relative to other options, the USNRC is proceeding with the rulemaking for design basis LOCA redefinition. An instantaneous break with a flow rate equivalent to a double ended guillotine break (DEGB) of the largest primary piping system in the plant is widely recognized as an extremely unlikely event, while redefinition of design basis LOCA can affect the existing regulatory practices and approaches. In this study, the status of the design basis LOCA redefinition and OECD/NEA SMAP (Safety Margin Action Plan) methodology are introduced. Preliminary evaluation methodology of ECCS performance for LOCA is developed and discussed for design basis LOCA redefinition

  15. Experiment data of ROSA-III integral test Run 7341

    International Nuclear Information System (INIS)

    Anoda, Yoshinari; Soda, Kunihisa; Tasaka, Kanji

    1983-02-01

    This report presents the test data of Run 7341 in the single failure test series of the ROSA-III program to conduct the system effect test concerning the response of a BWR during a LOCA with the ECC injection. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6 with an electrically heated core and the scaled ECCS. Run 7341 is a double-ended break test at the recirculation pump inlet with the assumption that all ECCS function as designed. The test is initiated with the steam dome pressure of 7.28 MPa, the lower plenum subcooling of 11.0 K, the core inlet flow rate of 15.3 kg/s, and the core heat generation rate of 3.55 MW and proceeded as planned. The whole core is quenched after the ECCS actuation and the maximum fuel cladding temperature is 810 K. The effectiveness of ECC injection has been clarified from the comparison of the test results with those of the other test in the series without ECCS. (author)

  16. The prevalence and risks of early childhood caries (ECC) in Toronto, Canada.

    Science.gov (United States)

    Al-Jewair, Thikriat S; Leake, James L

    2010-10-14

    To determine the prevalence and risks of early childhood caries (ECC) among children less than 71 months of age in Toronto, Canada, and to evaluate the association between parental/caregiver depression and ECC. A secondary analysis of data previously collected by the Toronto Public Health as part of the 2003 Toronto Perinatal and Child Health Survey was performed. The 90-item survey was conducted over the telephone to 1,000 families with children from zero years (birth) to six years of age. Parents/caregivers were asked about factors related to the development and health of their children. For this study, only children younger than six years of age (less than 71 months) were included (n=833). The primary outcome of interest was self-reported and measured by the response to the question of whether a physician/dentist had ever told the parent/caregiver his/her child had ECC. The prevalence of ECC was 4.7 percent (37 of 791 children). The child's age, his/her history of dental visits, teeth brushing, the use of fluoridated toothpaste, the parent's/caregiver's depressive tendencies, the language spoken at home, and the household annual income were all significant in the bivariate analysis. Multiple logistic regression identified four factors associated with ECC: the child's age (being three years of age or older), having at least one parent/caregiver with depression, not speaking English at home, and having an annual household income less than $40,000 in Canadian dollars (CAD). While a child's age, home language, and household income are known risks for ECC, the finding that parental/caregiver depression may be related to ECC is new. Multiple risk factors are involved in the development of early childhood caries. Of particular importance are demographic (e.g., child's age), social (e.g., annual household income), and psychosocial factors (e.g., parental/caregiver depression) that are indirectly linked to ECC. More attention needs to be placed on understanding the role

  17. Holistic care patient with Early Childhood Caries (ECC: A case report

    Directory of Open Access Journals (Sweden)

    Intan Maulani

    2016-06-01

    Full Text Available Early Childhood Caries (ECC is a specific form of severe dental caries that affects infants and young children. ECC progresses rapidly in those who are at high risk, and often goes untreated. Children experiencing caries as infants or toddlers have a much greater probability of subsequent caries in both primary and permanent dentitions. This case showed management holistic care for children with ECC.A five year old boy patient accompanied with her parents were reported to the Pedodontic Clinic Padjadjaran University Dental Hospital with a chief complaint of decayed upper anterior teeth and pain in the molar teeth. Clinical examinations found dental caries almost all teeth in the maxilla and mandible. Based on panoramic radiograph, treatments that can be done are strip crown glass ionomer restorations, pulp treatments, extractions and fixed space maintainer. Patients diagnosed with severe ECC, patient and parents described on this type of caries. During treatment the patient was given oral hygiene instruction and recommend daily use of tooth mouse. After all treatment were completed, fluoride topical, and fissure sealants, recall check up after three months was scheduled. Holistic care needed in handling children with ECC.

  18. A LOCA analysis for AHWR caused by ECCS header rupture

    International Nuclear Information System (INIS)

    Chatterjee, B.; Gawai, Amol; Gupta, S.K.; Kushwaha, H.S.

    2000-01-01

    Loss of coolant accident (LOCA) analyses for the proposed 750 MWth Advanced Heavy Water Reactor (AHWR), initiated by the rupture of 8 inch NB ECCS header has been carried out. This paper narrates the description of AHWR and associated ECCS, postulated scenario with which the analyses is carried out, results, discussion and conclusion

  19. Is 300 Seconds ACT Safe and Efficient during MiECC Procedures?

    Science.gov (United States)

    Bauer, Adrian; Hausmann, Harald; Schaarschmidt, Jan; Szlapka, Michal; Scharpenberg, Martin; Eberle, Thomas; Hasenkam, J Michael

    2017-12-31

     The recommended minimum activated clotting time (ACT) level for cardiopulmonary bypass (CPB) of 480 seconds originated from investigations with bubble oxygenators and uncoated extracorporeal circulation (ECC) systems. Modern minimal invasive ECC (MiECC) systems are completely closed circuits containing a membrane oxygenator and a tip-to-tip surface coating. We hypothesized that surface coating and the "closed-loop" design allow the MiECC to safely run with lower ACT levels and that an ACT level of 300 seconds can be safely applied without thromboembolic complications. The aim of this study was to investigate the potential risks during application of reduced heparin levels in patients undergoing coronary surgery.  In this study, 68 patients undergoing coronary artery bypass grafting with MiECC were randomized to either the study group with an ACT target of 300 seconds or the control group with an ACT of 450 seconds. All other factors of MiECC remained unchanged.  The study group received significantly less heparin and protamine (heparin [international units] median [min-max], Red_AC: 32,800 [23,000-51,500] vs. Full_AC: 50,000 [35,000-65,000] p  ACT in the study group was significantly lower at the start of MiECC (mean ± standard deviation: study group 400 ± 112 vs. control group 633 ± 177; p  ACT levels were: study group 344 ± 60 versus control group 506 ± 80. In both groups, the values of the endogenous thrombin potential (ETP) decreased simultaneously. None of the study participants experienced thromboembolic complications.  Since no evidence of increased thrombin formation (ETP) was found from a laboratory standpoint, we concluded that the use of MiECC with a reduced anticoagulation strategy seems possible. This alternative anticoagulation strategy leads to significant reduction in dosages of both heparin and protamine. We can confidently move forward with investigating this anticoagulation concept. However, to

  20. On the energy shift of the ECC cusp. Does the shift really exist?

    International Nuclear Information System (INIS)

    Barrachina, R.O.; Sarkadi, L.

    2004-01-01

    Full text: The cusplike 'electron capture to the continuum' (ECC) peak appearing in the spectrum of the forward emitted electrons in ion-atom collisions is generally thought to be a divergence. The peak is centered at electron velocity that matches that of the projectile. Recently Illescas et al. [1] claimed, however, that 'the cusp is not a divergence smoothed by the experiment, and is slightly shifted from the impact-velocity value'. In a subsequent work Shah et al. [2] measured the ECC cusp for collisions of 10- and 20- keV protons with H2 and He, and found that the peak was indeed shifted to a velocity below its expected position. Their classical trajectory Monte Carlo (CTMC) calculations reproduced the observation well. In the present work we demonstrate by our CTMC calculations (made for the case of 20-keV protons on He) that the intensity, width and position of the ECC cusp do depend on the experimental conditions by which the electrons are detected (first of all, the acceptance angle of the electron spectrometer). We also present experimental data for this collision system. While the latter data are well reproduced by our CTMC calculations, neither the theoretical results, nor the experimental data of the present work support of the findings of Shah et al. [2]. At the same time, analyzing the problem in the framework of the general final-state interaction theory of cusp formation [3], we concluded that 'rigorously' speaking Shah et al. [2] are right when they state that the ECC cusp is not a divergence. The divergence is smeared out by the scattering of the projectile. However, this effect is negligibly small at the lowest energy that was considered in their paper, 10 keV. At this impact energy the projectile motion is smeared within an angular region Δθ th ∼ 0.06 deg, which is much smaller than the acceptance angle of the experiment, Δθ exp ∼ 1.5 deg

  1. Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS

    International Nuclear Information System (INIS)

    Hanson, G.H.

    1978-01-01

    The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. LTR 113-47 has shown that the LOFT ECCS can be safely bypassed or disabled when the total core power does not exceed 25 kW. A modified policy involves disabling the automatic actuation of the LOFT ECCS, but still retaining the manual activation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 70 kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS

  2. ECC cusp analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pregliasco, R.G. (Centro Atomico Bariloche and CONICET, S.C. de Bariloche (Argentina)); Garibotti, C.R. (Centro Atomico Bariloche and CONICET, S.C. de Bariloche (Argentina)); Barrachina, R. (Centro Atomico Bariloche and CONICET, S.C. de Bariloche (Argentina))

    1994-03-01

    We measured the ionization double differential cross section for the H[sup +][yields]He 100 keV collision at the proximities of the ECC cusp and all around 0 . We propose an angular function expansion and a procedure for data analysis. We demonstrate that, in this way, the difficulties and shortcomings presented in the standard data processing are overcome. In our experimental results we distinguish the presence of characteristic shapes for the ionization depending on whether the module of the electron velocity is greater or smaller than the projectile velocity. (orig.)

  3. Intercomparison of ozone measurements between Lidar and ECC-sondes

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, G.C. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Boesenberg, J. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Dier, H. [Meteorologisches Obs., Lindenberg (Germany); Goersdorf, U. [Meteorologisches Obs., Lindenberg (Germany); Matthias, V. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Peters, G. [Meteorologisches Obs., Lindenberg (Germany); Schaberl, T. [Hamburg Univ. (Germany). Meteorologisches Inst.; Senff, C. [Hamburg Univ. (Germany). Meteorologisches Inst.

    1996-02-01

    An intercomparison experiment for measurements of ozone vertical profiles in the lower troposphere was performed using a ground-based ozone DIAL (DIfferential Absorption Lidar) and ECC-sondes (Electrochemical Concentration Cell) attached to tethered as well as free flying balloons, which took place in June of 1994. The tethered balloon was used for ozone soundings in the planetary boundary layer up to an altitude of 500 m, while in the free troposphere free flying balloons were used. For the time series of up to 90 min obtained with the tethersondes both averages and standard deviations are compared. The mean difference for all measurements amounted to 3.5 {mu}g/m{sup 3} only, corresponding to 3.5%. For the instantaneous profiles compared to the free flying sondes the differences were only marginally larger, with a mean value of 3.6 {mu}g/m{sup 3} corresponding to 4.1%. With two exceptions all averages for a single profile stayed below 7 {mu}g/m{sup 3}. Larger individual excursions were observed. In some cases, in particular in regions of steep aerosol gradients at layer boundaries, most probably the lidar values cause the deviation, while in other cases the ECC-sonde is suspected to yield erroneous results. For the measured standard deviation those retrieved from DIAL measurements are generally larger than measured by the ECC-sondes, especially in regions of inhomogeneous aerosol distribution. For the measurements reported here, this is attributed to residual errors in the aerosol correction of the DIAL measurements. The general agreement found in this intercomparison is regarded as excellent, DIAL is proven to be a very valuable tool for detailed studies of the ozone distribution in the lower troposphere. (orig.)

  4. The JAERI code system for evaluation of BWR ECCS performance

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Akimoto, Masayuki; Asahi, Yoshiro; Abe, Kiyoharu; Muramatsu, Ken; Araya, Fumimasa; Sato, Kazuo

    1982-12-01

    Development of respective computer code system of BWR and PWR for evaluation of ECCS has been conducted since 1973 considering the differences of the reactor cooling system, core structure and ECCS. The first version of the BWR code system, of which developmental work started earlier than that of the PWR, has been completed. The BWR code system is designed to provide computational tools to analyze all phases of LOCAs and to evaluate the performance of the ECCS including an ''Evaluation Model (EM)'' feature in compliance with the requirements of the current Japanese Evaluation Guideline of ECCS. The BWR code system could be used for licensing purpose, i.e. for ECCS performance evaluation or audit calculations to cross-examine the methods and results of applicants or vendors. The BWR code system presented in this report comprises several computer codes, each of which analyzes a particular phase of a LOCA or a system blowdown depending on a range of LOCAs, i.e. large and small breaks in a variety of locations in the reactor system. The system includes ALARM-B1, HYDY-B1 and THYDE-B1 for analysis of the system blowdown for various break sizes, THYDE-B-REFLOOD for analysis of the reflood phase and SCORCH-B2 for the calculation of the fuel assembl hot plane temperature. When the multiple codes are used to analyze a broad range of LOCA as stated above, it is very important to evaluate the adequacy and consistency between the codes used to cover an entire break spectrum. The system consistency together with the system performance are discussed for a large commercial BWR. (author)

  5. Safety design/analysis and scenario for prevention of CDA with ECCS in lead-bismuth-cooled fast reactor

    International Nuclear Information System (INIS)

    Minoru, Takahashi; Vaclav, Dostal; Abu Khalid, Rivai; Novitrian; Yumi, Yamada

    2007-01-01

    Safety design has been developed to show safety feature of Pb-Bi-cooled direct contact boiling water small fast reactor (PBWFR). The core is designed to have negative void reactivity even if the entire core and upper plenum are voided by steam intrusion from above. In-vessel type control rod driving mechanisms are used to prevent control rods from accidental ejection due to high pressure in the reactor vessel. In cases of coolant leakage from reactor vessel and feed water pipes, Pb-Bi coolant level in the reactor vessel is kept at the required level for decay heat removal by means of closed type guard vessel. Dual pipes are adopted to avoid leak of water in the feedwater system. Pump trip in feedwater systems initiates loss of coolant flow (LOF) event, although there is no concern of loss of flow accident due to primary pump trip. Injection of high pressure water slows down the flow-coast-down of feedwater at the LOF event. It has been evaluated that the fuel temperature is kept lower than safety limits at the unprotected loss of flow and heat sink (ATWS). A scenario for prevention of the core disruptive accident (CDA) with the emergency core cooling system (ECCS) is examined. The reactor becomes super-critical when the reactor vessel is filled with water. It is necessary to use water with boric acid for the ECC system, and additional backup rods for sub-critical core in water injection. (authors)

  6. Verification of the code ATHLET by post-test analysis of two experiments performed at the CCTF integral test facility

    International Nuclear Information System (INIS)

    Krepper, E.; Schaefer, F.

    2001-03-01

    In the framework of the external validation of the thermohydraulic code ATHLET Mod 1.2 Cycle C, which has been developed by the GRS, post test analyses of two experiments were done, which were performed at the japanese test facility CCTF. The test facility CCTF is a 1:25 volume-scaled model of a 1000 MW pressurized water reactor. The tests simulate a double end break in the cold leg of the PWR with ECC injection into the cold leg and with combined ECC injection into the hot and cold legs. The evaluation of the calculated results shows, that the main phenomena can be calculated in a good agreement with the experiment. Especially the behaviour of the quench front and the core cooling are calculated very well. Applying a two-channel representation of the reactor model the radial behaviour of the quench front could be reproduced. Deviations between calculations and experiment can be observed simulating the emergency injection in the beginning of the transient. Very high condensation rates were calculated and the pressure decrease in this phase of the transient is overestimated. Besides that, the pressurization due to evaporation in the refill phase is underestimated by ATHLET. (orig.) [de

  7. Accomplishments of LOCA/ECCS experimental research at Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Murao, Yoshio; Koizumi, Yasuo

    1984-01-01

    Japan Atomic Energy Research Institute has investigated loss-of-coolant accident (LOCA)/emergency core cooling system (ECCS) from 1970. Major results of the LOCA/ECCS research are summarized in this report. ROSA-II program was LOCA/ECCS research for a pressurized water reactor (PWR) and ROSA-III program was for a boiling water reactor (BWR). The both test facilities were scaled at approximately 1/400 of the respective reference PWR and BWR. Large scale reflood test is research on reflood phenomena during a large break LOCA of PWR. The test facility is scaled at approximately 1/20 of the reference PWR and the research is still being continued. (author)

  8. Analysis of emergency core cooling capability of direct vessel vertical injection using CFX

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Yu, Yong H.; Suh, Kune Y.

    2003-01-01

    More reliable and efficient safety injection system is of utmost importance in the design of advanced reactors such as the APR1400 (Advanced Power Reactor 1400 MWe). In this work, a new idea is proposed to inject the Emergency Core Cooling (ECC) water utilizing a dedicated nozzle with a vertically downward elbow. The Direct Vessel Injection (DVI) system is located horizontally above the cold leg in the APR1400. However, the horizontal injection method may not always satisfy the ECC penetration requirement into the core on account of rather involved multidimensional thermal and hydraulic phenomena occurring in the annular reactor downcomer such as bypass, impingement, entrainment and sweepout, condensation oscillation, etc. Thus, a novel concept is called for from the reactor safety point of view. The Direct Vessel Vertical Injection (DVVI) system is one of these efforts to penetrate as much the ECC water through the downcomer into the core as is practically achievable. The DVVI system can increase the momentum of the downward flow, thus minimizing the effect of water impingement on the core barrel and the direct bypass though the break. To support the claim of increased downward momentum of flow in the DVVI system, computational fluid dynamics analyses were performed using CFX. The new concept of the DVVI system, which can certainly help increase the core thermal margin, is found to be more efficient than DVI. If the structural problem in the manufacturing process is properly solved, this concept can safely be applied in the advanced nuclear reactor design

  9. Application of Interfacial Propagation and Kinking Crack Concept to ECC/Concrete Overlay Repair System

    Directory of Open Access Journals (Sweden)

    Yaw ChiaHwan

    2014-01-01

    Full Text Available Research on the application of ultraductile engineered cementitious composite (ECC as overlay in the repair of deteriorated concrete structures is performed in this paper. Also, interfacial crack kinking and trapping mechanism experimentally observed in ECC/concrete overlay repair system are described by comparison of toughness and energy release rate. The mechanism involves cycles of extension, kinking, and arrest of interfacial crack into the overlay. Experimental testing of overlay repair system reveals significant improvements in load carrying capacity and ductility over conventional concrete overlay. The commonly observed overlay system failure mode of delamination or spalling is eliminated when ECC is applied. These failure modes are suppressed when ECC is used as an ideal and durable candidate overlay repair material.

  10. Measurement and analysis of the ECC cusp structure

    Energy Technology Data Exchange (ETDEWEB)

    Pregliasco, R.G.; Garibotti, C.R.; Barrachina, R.O. (Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico Bariloche)

    1994-03-28

    We measured the electron capture to the continuum (ECC) peak in the ionization of He atoms by the collision of 50, 100 and 200 keV H[sup +] and 100 keV amu[sup -1]He[sup 2+]. We exhaustively scanned the double differential cross section between the angles -1.5[sup o] to 10[sup o] and within the velocities (1 [+-] 0.15)[upsilon][sub i] where [upsilon][sub i] is the impact velocity. We propose a new method for analysing the ECC structure which is independent of the spectrometer transmission function modellization and enables a direct comparison with the available theories. Furthermore, we distinguish two regimes for the ionization process, depending on whether the electron velocity is larger or smaller than the projectile velocity. (Author).

  11. Noise-based Stego-ECC

    Directory of Open Access Journals (Sweden)

    Rahardjo Budi

    2014-03-01

    Full Text Available A novel method of inserting noise into stream of ciphered text is proposed. The goal of inserting noise is to increase the level of uncertainty, thus making it harder for an attacker to detect data and noise. This form of steganography is implemented using Elliptic Curve Cryptography (ECC. The process of embedding the noise to the message in the encryption process and removing the noise from the message in the decryption process is proposed in this work by modifying ElGamal to allow auto detection of data and noise.

  12. Gravity driven emergency core cooling experiments with the PACTEL facility

    International Nuclear Information System (INIS)

    Munther, R.; Kalli, H.; Kouhia, J.

    1996-01-01

    PACTEL (Parallel Channel Test Loop) is an experimental out-of-pile facility designed to simulated the major components and system behaviour of a commercial Pressurized Water Reactor (PWR) during different postulated LOCAs and transients. The reference reactor to the PACTEL facility is Loviisa type WWER-440. The recently made modifications enable experiments to be conducted also on the passive core cooling. In these experiments the passive core cooling system consisted of one core makeup tank (CMT) and pressure balancing lines from the pressurizer and from a cold leg connected to the top of the CMT in order to maintain the tank in pressure equilibrium with the primary system during ECC injection. The line from the pressurizer to the core makeup tank was normally open. The ECC flow was provided from the CMT located at a higher elevation than the main part of the primary system. A total number of nine experiments have been performed by now. 4 refs, 7 figs, 3 tabs

  13. Gravity driven emergency core cooling experiments with the PACTEL facility

    Energy Technology Data Exchange (ETDEWEB)

    Munther, R; Kalli, H [University of Technology, Lappeenranta (Finland); Kouhia, J [Technical Research Centre of Finland, Lappeenranta (Finland)

    1996-12-01

    PACTEL (Parallel Channel Test Loop) is an experimental out-of-pile facility designed to simulated the major components and system behaviour of a commercial Pressurized Water Reactor (PWR) during different postulated LOCAs and transients. The reference reactor to the PACTEL facility is Loviisa type WWER-440. The recently made modifications enable experiments to be conducted also on the passive core cooling. In these experiments the passive core cooling system consisted of one core makeup tank (CMT) and pressure balancing lines from the pressurizer and from a cold leg connected to the top of the CMT in order to maintain the tank in pressure equilibrium with the primary system during ECC injection. The line from the pressurizer to the core makeup tank was normally open. The ECC flow was provided from the CMT located at a higher elevation than the main part of the primary system. A total number of nine experiments have been performed by now. 4 refs, 7 figs, 3 tabs.

  14. Quorum sensing in the plant pathogen Erwinia carotovora subsp. carotovora: the role of expR(Ecc).

    Science.gov (United States)

    Andersson, R A; Eriksson, A R; Heikinheimo, R; Mäe, A; Pirhonen, M; Kõiv, V; Hyytiäinen, H; Tuikkala, A; Palva, E T

    2000-04-01

    The production of the main virulence determinants of the plant pathogen Erwinia carotovora subsp. carotovora, the extracellular cell wall-degrading enzymes, is partly controlled by the diffusible signal molecule N-(3-oxohexanoyl)-L-homoserine lactone (OHHL). OHHL is synthesized by the product of the expI/carI gene. Linked to expI we found a gene encoding a putative transcriptional regulator of the LuxR-family. This gene, expR(Ecc), is transcribed convergently to the expI gene and the two open reading frames are partially overlapping. The ExpR(Ecc) protein showed extensive amino acid sequence similarity to the repressor EsaR from Pantoea stewartii subsp. stewartii (formerly Erwinia stewartii subsp. stewartii) and to the ExpR(Ech) protein of Erwinia chrysanthemi. Inactivation of the E. carotovora subsp. carotovora expR(Ecc) gene caused no decrease in virulence or production of virulence determinants in vitro. In contrast, there was a slight increase in the maceration capacity of the mutant strain. The effects of ExpR(Ecc) were probably mediated by changes in OHHL levels. Inactivation of expR(Ecc) resulted in increased OHHL levels during early logarithmic growth. In addition, overexpression of expR(Ecc) caused a clear decrease in the production of virulence determinants and part of this effect was likely to be caused by OHHL binding to ExpR(Ecc). ExpR(Ecc) did not appear to exhibit transcriptional regulation of expI, but the effect on OHHL was apparently due to other mechanisms.

  15. Application of Engineered Cementitious Composites (ECC) in modular floor panels

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2008-01-01

    This paper describes the design, manufacturing, and structural behavior of a prefabricated floor panel consisting of a modular assembly of a thin-walled ECC slab and steel truss girders. The features of this composite structure include light weight, the modular manufacturing process...... concept introduced in this paper aims at improvements in the manufacturing process of the panels by casting the ECC slab separately and subsequently joining it with the steel trusses. The focus of this paper is on design and manufacturing of a prototype modular panel and on its structural behavior under...

  16. ECC2K-130 on NVIDIA GPUs

    NARCIS (Netherlands)

    Bernstein, D.J.; Chen, H.-C.; Cheng, C.M.; Lange, T.; Niederhagen, R.F.; Schwabe, P.; Yang, B.Y.

    2012-01-01

    [Updated version of paper at Indocrypt 2010] A major cryptanalytic computation is currently underway on multiple platforms, including standard CPUs, FPGAs, PlayStations and GPUs, to break the Certicom ECC2K-130 challenge. This challenge is to compute an elliptic-curve discrete logarithm on a Koblitz

  17. ECC2K-130 on NVIDIA GPUs

    NARCIS (Netherlands)

    Bernstein, D.J.; Chen, H.-C.; Cheng, C.M.; Lange, T.; Niederhagen, R.F.; Schwabe, P.; Yang, B.Y.; Gong, G.; Gupta, K.C.

    2010-01-01

    A major cryptanalytic computation is currently underway on multiple platforms, including standard CPUs, FPGAs, PlayStations and Graphics Processing Units (GPUs), to break the Certicom ECC2K-130 challenge. This challenge is to compute an elliptic-curve discrete logarithm on a Koblitz curve over $\\rm

  18. An overview of the BWR ECCS strainer blockage issues

    International Nuclear Information System (INIS)

    Serkiz, A.W.; Marshall, M.L. Jr.; Elliott, R.

    1996-01-01

    This Paper provides a brief overview of actions taken in the mid 1980s to resolve Unresolved Safety Issue (USI) A-43, open-quotes Containment Emergency Sump Performance,close quotes and their relationship to the BWR strainer blockage issue; the importance of insights gained from the Barseback-2 (a Swedish BWR) incident in 1992 and from ECCS strainer testing and inspections at the Perry nuclear power plant in 1992 and 1993; an analysis of an US BWR/4 with a Mark I containment; an international community sharing of knowledge relevant to ECCS strainer blockage, additional experimental programs; and identification of actions needed to resolve the strainer blockage issue and the status of such efforts

  19. Preparation and evaluation of 68Ga-ECC as a PET renal imaging agent

    International Nuclear Information System (INIS)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro; Geramifar, Patham; Beiki, Davood

    2015-01-01

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop 68 Ga-ethylenecysteamine cysteine ( 68 Ga-ECC). Ga-ECC was prepared using generator-based 68 GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). 68 Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV max ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous 99m Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time

  20. Interaction of Liquid Film Flow of Direct Vessel Injection Under the Cross Directional Gas Flow

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-sol; Lee, Jae-young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness and a hydraulic jump in the film flow and boundaries of the film flow. It was found that CFD analysis results without surface tension model showed some difference with the data in surface tension dominated flow region. For the interaction between a liquid film and gas shear flow, CFD results make a good agreement with the real liquid film dynamics in the case of low film Reynolds number or low Weber number flow. In the 1/20 scaled plate type experiment and simulation, the deformed spreading profile results seem to accord with each other at the relatively low We and Re regime.

  1. Lightweight ECC based RFID authentication integrated with an ID verifier transfer protocol.

    Science.gov (United States)

    He, Debiao; Kumar, Neeraj; Chilamkurti, Naveen; Lee, Jong-Hyouk

    2014-10-01

    The radio frequency identification (RFID) technology has been widely adopted and being deployed as a dominant identification technology in a health care domain such as medical information authentication, patient tracking, blood transfusion medicine, etc. With more and more stringent security and privacy requirements to RFID based authentication schemes, elliptic curve cryptography (ECC) based RFID authentication schemes have been proposed to meet the requirements. However, many recently published ECC based RFID authentication schemes have serious security weaknesses. In this paper, we propose a new ECC based RFID authentication integrated with an ID verifier transfer protocol that overcomes the weaknesses of the existing schemes. A comprehensive security analysis has been conducted to show strong security properties that are provided from the proposed authentication scheme. Moreover, the performance of the proposed authentication scheme is analyzed in terms of computational cost, communicational cost, and storage requirement.

  2. Gonioscopic changes in conventional ECCE vs manual SICS: A comparative study

    Directory of Open Access Journals (Sweden)

    Surya Joseph, Sundararajan D, Rajvin Samuel Ponraj, Srinivasan M, Veluchamy

    2014-04-01

    Full Text Available The aim of the study is to observe and compare the Gonioscopic changes in the angle of the anterior chamber of the eye after surgeries namely; Conventional Extra capsular cataract extraction (ECCE with Posterior chamber Intraocular lens (PC IOL implantation, Manual Small incision Cataract Surgery with PCIOL implantation. The clinical study was undertaken after Institutional Ethical committee clearance, securing the inform consent, total number of 100 patients were enrolled in the study. 50 ECCE; 50 SICS consisting of 57 Males and 43 Females aged between 40 – 80yrs who were admitted and operated for Cataract at Meenakshi Medical college Hospital & Research institute. The following parameters are studied: Gonioscopic changes in the angle, namely the PAS formation in the quadrants, pigment dispersion in each of the methods. After this study, we arrive to a conclusion that complications in the angle of anterior chamber occur mostly in Conventional with insignificant change in manual SICS. So manual Small incision Cataract Surgery with PCIOL implantation is preferable over Conventional ECCE with PCIOL implantation.

  3. Numerical simulation of boron injection in a BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tinoco, Hernan, E-mail: htb@forsmark.vattenfall.s [Forsmarks Kraftgrupp AB, SE-742 03 Osthammar (Sweden); Buchwald, Przemyslaw [Reactor Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Frid, Wiktor, E-mail: wiktor@reactor.sci.kth.s [Reactor Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden)

    2010-02-15

    The present study constitutes a first step to understand the process of boron injection, transport and mixing in a BWR. It consists of transient CFD simulations of boron injection in a model of the downcomer of Forsmark's Unit 3 containing about 6 million elements. The two cases studied are unintentional start of boron injection under normal operation and loss of offsite power with partial ATWS leaving 10% of the core power uncontrolled. The flow conditions of the second case are defined by means of an analysis with RELAP5, assuming boron injection start directly after the first ECCS injection. Recent publications show that meaningful conservative results may be obtained for boron or thermal mixing in PWRs with grids as coarse as that utilized here, provided that higher order discretization schemes are used to minimize numerical diffusion. The obtained results indicate an apparently strong influence of the scenario in the behavior of the injection process. The normal operation simulation shows that virtually all boron solution flows down to the Main Recirculation Pump inlet located directly below the boron inlet nozzle. The loss of offsite power simulation shows initially a spread of the boron solution over the entire sectional area of the lower part of the downcomer filled with colder water. This remaining effect of the ECCS injection lasts until all this water has left the downcomer. Above this region, the boron injection jet develops in a vertical streak, eventually resembling the injection of the normal operation scenario. Due to the initial spread, this boron injection will probably cause larger temporal and spatial concentration variations in the core. In both cases, these variations may cause reactivity transients and fuel damage due to local power escalation. To settle this issue, an analysis using an extended model containing the downcomer, the MRPs and the Lower Plenum will be carried out. Also, the simulation time will be extended to a scale of

  4. Numerical simulation of boron injection in a BWR

    International Nuclear Information System (INIS)

    Tinoco, Hernan; Buchwald, Przemyslaw; Frid, Wiktor

    2010-01-01

    The present study constitutes a first step to understand the process of boron injection, transport and mixing in a BWR. It consists of transient CFD simulations of boron injection in a model of the downcomer of Forsmark's Unit 3 containing about 6 million elements. The two cases studied are unintentional start of boron injection under normal operation and loss of offsite power with partial ATWS leaving 10% of the core power uncontrolled. The flow conditions of the second case are defined by means of an analysis with RELAP5, assuming boron injection start directly after the first ECCS injection. Recent publications show that meaningful conservative results may be obtained for boron or thermal mixing in PWRs with grids as coarse as that utilized here, provided that higher order discretization schemes are used to minimize numerical diffusion. The obtained results indicate an apparently strong influence of the scenario in the behavior of the injection process. The normal operation simulation shows that virtually all boron solution flows down to the Main Recirculation Pump inlet located directly below the boron inlet nozzle. The loss of offsite power simulation shows initially a spread of the boron solution over the entire sectional area of the lower part of the downcomer filled with colder water. This remaining effect of the ECCS injection lasts until all this water has left the downcomer. Above this region, the boron injection jet develops in a vertical streak, eventually resembling the injection of the normal operation scenario. Due to the initial spread, this boron injection will probably cause larger temporal and spatial concentration variations in the core. In both cases, these variations may cause reactivity transients and fuel damage due to local power escalation. To settle this issue, an analysis using an extended model containing the downcomer, the MRPs and the Lower Plenum will be carried out. Also, the simulation time will be extended to a scale of several

  5. CFD Analysis of the Safety Injection Tank and Fluidic Device

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Nietiadi, Yohanes Setiawan; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Addad, Yacine [KUSTAR, Abu Dhabi (United Arab Emirates)

    2016-05-15

    One of the most important components in the ECCS is the safety injection tank (SIT). Inside the SIT, a fluidic device is installed, which passively controls the mass flow of the safety injection and eliminates the need for low pressure safety injection pumps. As more passive safety mechanisms are being pursued, it has become more important to understand flow structure and the loss mechanism within the fluidic device. Current computational fluid dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study proposes to find a more exact result using CFD and more realistic modeling to predict the performance during accident scenarios more accurately. The safety injection tank with fluidic device was analyzed thoroughly using CFD. The preliminary calculation used 60,000 meshes for the initial test calculation. The results fit the experimental results surprisingly despite its coarse grid. Nonetheless, the mesh resolution was increased to capture the vortex in the fluidic device precisely. Once a detailed CFD computation is finished, a small-scale experiment will be conducted for the given conditions. Using the experimental results and the CFD model, physical models can be improved to fit the results more accurately.

  6. Preparation and evaluation of {sup 68}Ga-ECC as a PET renal imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro [Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Geramifar, Patham; Beiki, Davood [Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-09-15

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop {sup 68}Ga-ethylenecysteamine cysteine ({sup 68}Ga-ECC). Ga-ECC was prepared using generator-based {sup 68}GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). {sup 68}Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV{sub max} ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous {sup 99m}Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time.

  7. Corticosteroid injections, eccentric decline squat training and heavy slow resistance training in patellar tendinopathy

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Kovanen, V.; Aagaard, P.

    2009-01-01

    A randomized-controlled single-blind trial was conducted to investigate the clinical, structural and functional effects of peritendinous corticosteroid injections (CORT), eccentric decline squat training (ECC) and heavy slow resistance training (HSR) in patellar tendinopathy. Thirty-nine male...

  8. Cooling water injection system

    International Nuclear Information System (INIS)

    Inai, Nobuhiko.

    1989-01-01

    In a BWR type reactor, ECCS system is constituted as a so-called stand-by system which is not used during usual operation and there is a significant discontinuity in relation with the usual system. It is extremely important that ECCS operates upon occurrence of accidents just as specified. In view of the above in the present invention, the stand-by system is disposed along the same line with the usual system. That is, a driving water supply pump for supplying driving water to a jet pump is driven by a driving mechanism. The driving mechanism drives continuously the driving water supply pump in a case if an expected accident such as loss of the function of the water supply pump, as well as during normal operation. That is, all of the water supply pump, jet pump, driving water supply pump and driving mechanism therefor are caused to operate also during normal operation. The operation of them are not initiated upon accident. Thus, the cooling water injection system can perform at high reliability to remarkably improve the plant safety. (K.M.)

  9. Intricate and Cell Type-Specific Populations of Endogenous Circular DNA (eccDNA) in Caenorhabditis elegans and Homo sapiens.

    Science.gov (United States)

    Shoura, Massa J; Gabdank, Idan; Hansen, Loren; Merker, Jason; Gotlib, Jason; Levene, Stephen D; Fire, Andrew Z

    2017-10-05

    Investigations aimed at defining the 3D configuration of eukaryotic chromosomes have consistently encountered an endogenous population of chromosome-derived circular genomic DNA, referred to as extrachromosomal circular DNA (eccDNA). While the production, distribution, and activities of eccDNAs remain understudied, eccDNA formation from specific regions of the linear genome has profound consequences on the regulatory and coding capabilities for these regions. Here, we define eccDNA distributions in Caenorhabditis elegans and in three human cell types, utilizing a set of DNA topology-dependent approaches for enrichment and characterization. The use of parallel biophysical, enzymatic, and informatic approaches provides a comprehensive profiling of eccDNA robust to isolation and analysis methodology. Results in human and nematode systems provide quantitative analysis of the eccDNA loci at both unique and repetitive regions. Our studies converge on and support a consistent picture, in which endogenous genomic DNA circles are present in normal physiological states, and in which the circles come from both coding and noncoding genomic regions. Prominent among the coding regions generating DNA circles are several genes known to produce a diversity of protein isoforms, with mucin proteins and titin as specific examples. Copyright © 2017 Shoura et al.

  10. A Secure-Enhanced Data Aggregation Based on ECC in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Qiang Zhou

    2014-04-01

    Full Text Available Data aggregation is an important technique for reducing the energy consumption of sensor nodes in wireless sensor networks (WSNs. However, compromised aggregators may forge false values as the aggregated results of their child nodes in order to conduct stealthy attacks or steal other nodes’ privacy. This paper proposes a Secure-Enhanced Data Aggregation based on Elliptic Curve Cryptography (SEDA-ECC. The design of SEDA-ECC is based on the principles of privacy homomorphic encryption (PH and divide-and-conquer. An aggregation tree disjoint method is first adopted to divide the tree into three subtrees of similar sizes, and a PH-based aggregation is performed in each subtree to generate an aggregated subtree result. Then the forged result can be identified by the base station (BS by comparing the aggregated count value. Finally, the aggregated result can be calculated by the BS according to the remaining results that have not been forged. Extensive analysis and simulations show that SEDA-ECC can achieve the highest security level on the aggregated result with appropriate energy consumption compared with other asymmetric schemes.

  11. BREASTFEEDING AND EARLY CHILDHOOD CARIES (ECC SEVERITY OF CHILDREN UNDER THREE YEARS OLD IN DKI JAKARTA

    Directory of Open Access Journals (Sweden)

    Risqa Rina Darwita

    2008-12-01

    Full Text Available The prevalence and severity of caries in children under three years old are constantly increasing. One of the cause is the increase consumption of cariogenic carbohydrate. Breast milk have buffer capacity that eventually able to prevent caries. The aims of this research are to discover the correlation between breastfeeding with the severity of Early Childhood Caries (ECC in children under three years old, to provide information on prevalence and severity of caries in children under three years, and to explain factors influencing the incidence of ECC. This research designed cross sectionally and conducted upon 565 children aged 12-38 months, selected using multistage cluster random sampling. The ECC prevalence of children under three years in DKI Jakarta is 52.7%, with average score of def-t 2.85. Bivariate analysis showed that, variables which correlate with the level of ECC are; the way to deliver (p=0,012, frequency (p=0,002, duration (p=0,002, salivary buffer capacity (p=0.013, habitual consumption of sugary diet (p=0.005, child’s dental hygiene behavior (p=0.002, and mother’s education (p=0.001. Multivariate analysis showed that ECC can be explained by these variables: age, mother’s education, the way to deliver and frequency of breast milk complements/replacement of consumtions, child’s brushing habit, plaque pH, and salivary buffer capacity. Resulting determination coefficient 32.1%. There is no significant correlation between breastfeeding and the level of Early Childhood Caries (ECC. The role of protective qualities of breastfeeding are not shown because of bias in obtaining data influence the incidence of caries.

  12. Comparison of allele frequency for HLA-DR and HLA-DQ between patients with ECC and caries-free children

    Directory of Open Access Journals (Sweden)

    Bagherian A

    2008-03-01

    Full Text Available Background: Early childhood caries (ECC is one of the most common diseases of childhood. The etiology of ECC is multifactorial and both genetic and environmental factors play important roles in the pathogenesis of the disease. Genetic variations in the hosts may contribute to changes in the risk for dental caries. Genetic factors such as human leukocyte antigen (HLA have recently been suggested as a predisposing factor. Aim: The aim of this study was to look for an association between HLA-DRB1 and HLA-DQB1 with ECC for developing new strategies for the diagnosis as well as the prevention of the disease. Design: In this study, we extracted the genomic DNAs from whole blood samples of 44 patients with ECC and 35 caries-free children by the salting-out method. We amplified the genomic DNA by PCR-SSP and then HLA-typing was performed for all alleles. Results: The results revealed a significant increase in the frequency of HLA-DRB1FNx0104 in the patient group (P = 0.019. The odds ratio for this allele was detected to be 10. The frequency of HLA-DQB1 alleles was not significantly different between the two groups. Conclusion: The above results suggest that HLA-DRB1FNx0104 is associated with the susceptibility to ECC. Thus HLA-DRB1FNx0104 detection as a molecular marker for early diagnosis of ECC may be recommended.

  13. Simulation of a large break loss of coolant (LBLOCA), without actuation of the emergency injection systems (ECCS) for a BWR-5

    International Nuclear Information System (INIS)

    Cardenas V, J.; Mugica R, C. A.; Lopez M, R.

    2015-09-01

    In this paper the analysis of scenario for the loss of coolant case was realized with break at the bottom of a recirculation loop of a BWR-5 with containment type Mark II and a thermal power of 2317 MWt considering that not have coolant injection. This in order to observe the speed of progression of the accident, the phenomenology of the scenario, the time to reach the limit pressure of containment venting and the amount of radionuclides released into the environment. This simulation was performed using the MELCOR code version 2.1. The scenario posits a break in one of the shear recirculation loops. The emergency core cooling system (ECCS) and the reactor core isolation cooling (Rcic) have not credit throughout the event, which allowed achieve greater severity on scenario. The venting of the primary containment was conducted via valve of 30 inches instead of the line of 24 inches of wet well, this in order to have a larger area of exhaust of fission products directly to the reactor building. The venting took place when the pressure in the primary containment reached the 4.5 kg/cm 2 and remained open for the rest of the scenario to maximize the amount released of radionuclides to the atmosphere. The safety relief valves were considered functional they do not present mechanical failure or limit their ability to release pressure due to the large number of performances in safety mode. The results of the analysis covers about 48 hours, time at which the accident evolution was observed; behavior of level, pressure in the vessel and the fuel temperature profile was analyzed. For progression of the scenario outside the vessel, the pressure and temperature of the primary containment, level and temperature of the suppression pool, the hydrogen accumulation in the container and the radionuclides mass released into the atmosphere were analyzed. (Author)

  14. ECCS evaluation of B and W's 205-FA NSS

    International Nuclear Information System (INIS)

    Lowe, R.J.; Anderson, G.E. Jr.; Dunn, B.M.

    1975-06-01

    The effectiveness of the ECCS for B and W's 205-fuel assembly plants is evaluated and shown to meet all the requirements of 10 CFR 50.46. The results of various sensitivity studies, a spectrum of breaks, and an analysis to determine allowable linear heat rates under 10 CFR 50.46 are presented. (14 references) (U.S.)

  15. A study on design of the trip computer for ECCS based on dynamic safety system

    International Nuclear Information System (INIS)

    Kim, Seog Nam

    2000-02-01

    The Emergency Core Cooling system in current nuclear power plants typically has a considerable number of complex functions and largely cumbersome operator interfaces. Functions for initiation, switch-over between various phases of operation, interlocks, monitoring, and alarming are usually performed by relay and analog comparator logic which is difficult to maintain and test. To improve problems of an analog based ECC (Emergency Core Cooling) System, the trip computer for ECCS based on Dynamic Safety System is implemented. The Dynamic Safety System (DSS) is a computer based reactor protection system that has fail-safe nature and performs a dynamic self-testing. The most important feature of the DSS is the introduction of test signal that send the system into a tripped state. The test signals are interleaved between the plant signals to produce an output which switches between a tripped and health state. The dynamic operation is a key feature of the failsafe design of the system. In this thesis, a possible implementation of the DSS using PLC is presented for a CANDU reactor. ECC System of the CANDU Reactor is selected as the reference system. The function of the DSS is implemented In PLC with the CONCEPT language. CONCEPT was developed by GROUPE SCHNEIDER as a graphic user interface programming tool for the Quantum PLC. A MMI display for ECCS based on DSS is implemented with LOOKOUT as an object driven programming tool. The Validation test has been performed by S/W Input Simulator as per Validation Test Procedure. The result of the test was checked and displayed on the MMI display. From the test results, it is shown that the DSS based ECC System operates correctly in all conditions

  16. A PWR reactor downcomer modification for reduction of ECC bypass flow during LOCA

    International Nuclear Information System (INIS)

    Popov, N.; Bosevski, T.

    1986-01-01

    The ECC bypass phenomenon in the PWR reactor down-comer, which delays the reactor vessel refilling, after cold leg large break LOCA accident, has been subject of analysis in this paper. In the paper, a particular construction modification of the reactor down-comer has been suggested by inserting vertical ribs, aimed to intensify the reactor ECC refilling following the LOCA accident, and to advance the thermal-hydraulics safety of post-accidental cooling of the PWR reactors. To verify the effectiveness of the suggested down-comer construction modification, some properly selected results, obtained by corresponding verified mathematical model, have been presented in this paper. (author)

  17. Results and analysis of the TMX electron-beam injection experiments

    International Nuclear Information System (INIS)

    Poulsen, P.; Grubb, D.P.

    1980-01-01

    Electron beams (e-beams) were injected into the Tandem Mirror Experiment (TMX) plasma in order to investigate the effect on the ion cyclotron fluctuations of the plasma. The power level of the e-beams was comparable to that of the injected neutral beams. It was found that injection of the e-beams produced no significant effect on the ion cyclotron fluctuations, the measured plasma parameters, or the particle and power flow of the plasma. The increase in bulk electron temperature and the production of mirror-confined electrons found in previous experiments in which e-beams were injected into a mirror-confined plasma were not observed in this experiment. Analysis of the regions and frequencies of wave creation and absorption within the plasma shows that the plasma density and magnetic field profiles through the plasma strongly affect the resonances encountered by the waves. The steep axial density profiles produced by neutral-beam injection in the TMX experiment are not conducive to efficient coupling of the e-beam energy to the plasma

  18. Modeling of ECC materials using numerical formulations based on plasticity

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  19. Disease Management of Early Childhood Caries: ECC Collaborative Project.

    Science.gov (United States)

    Ng, Man Wai; Ramos-Gomez, Francisco; Lieberman, Martin; Lee, Jessica Y; Scoville, Richard; Hannon, Cindy; Maramaldi, Peter

    2014-01-01

    Until recently, the standard of care for early childhood caries (ECC) has been primarily surgical and restorative treatment with little emphasis on preventing and managing the disease itself. It is now recognized that surgical treatment alone does not address the underlying etiology of the disease. Despite costly surgeries and reparative treatment, the onset and progression of caries are likely to continue. A successful rebalance of risk and protective factors may prevent, slow down, or even arrest dental caries and its progression. An 18-month risk-based chronic disease management (DM) approach to address ECC in preschool children was implemented as a quality improvement (QI) collaborative by seven teams of oral health care providers across the United States. In the aggregate, fewer DM children experienced new cavitation, pain, and referrals to the operating room (OR) for restorative treatment compared to baseline historical controls. The teams found that QI methods facilitated adoption of the DM approach and resulted in improved care to patients and better outcomes overall. Despite these successes, the wide scale adoption and spread of the DM approach may be limited unless health policy and payment reforms are enacted to compensate providers for implementing DM protocols in their practice.

  20. Minimum containment pressure and its effect on ECCS performance of APR-1400

    International Nuclear Information System (INIS)

    Kim, In Goo; Bang, Young S.; Kim, Hho Jung

    2004-01-01

    The containment pressure has a strong effect on the late reheat behavior for a large break LOCA, associated with the DVI issue. The downcomer boiling, which occurs during the post-reflood phase, has a negative effect on core cooling for a LBLOCA. Because the downcomer boiling is enhanced as the containment pressure decreases, how to determine containment pressure is important to the evaluation of ECCS performance. In spite of its importance of containment pressure, there are few studies on the containment pressure and the interaction between RCS and containment thermal hydraulics. To have a better knowledge of the effect of containment pressure on APR-1400 ECCS performance, a parametric study for containment pressure has been carried out. Also, the interaction between RCS and containment behavior has been also investigated

  1. Compendium of ECCS [Emergency Core Cooling Systems] research for realistic LOCA [loss-of-coolant accidents] analysis: Final report

    International Nuclear Information System (INIS)

    1988-12-01

    In the United States, Emergency Core Cooling Systems (ECCS) are required for light water reactors (LWRs) to provide cooling of the reactor core in the event of a break or leak in the reactor piping or an inadvertent opening of a valve. These accidents are called loss-of-coolant accidents (LOCA), and they range from small leaks up to a postulated full break of the largest pipe in the reactor cooling system. Federal government regulations provide that LOCA analysis be performed to show that the ECCS will maintain fuel rod cladding temperatures, cladding oxidation, and hydrogen production within certain limits. The NRC and others have completed a large body of research which investigated fuel rod behavior and LOCA/ECCS performance. It is now possible to make a realistic estimate of the ECCS performance during a LOCA and to quantify the uncertainty of this calculation. The purpose of this report is to summarize this research and to serve as a general reference for the extensive research effort that has been performed. The report: (1) summarizes the understanding of LOCA phenomena in 1974; (2) reviews experimental and analytical programs developed to address the phenomena; (3) describes the best-estimate computer codes developed by the NRC; (4) discusses the salient technical aspects of the physical phenomena and our current understanding of them; (5) discusses probabilistic risk assessment results and perspectives, and (6) evaluates the impact of research results on the ECCS regulations. 736 refs., 412 figs., 66 tabs

  2. Flux-Level Transit Injection Experiments with NASA Pleiades Supercomputer

    Science.gov (United States)

    Li, Jie; Burke, Christopher J.; Catanzarite, Joseph; Seader, Shawn; Haas, Michael R.; Batalha, Natalie; Henze, Christopher; Christiansen, Jessie; Kepler Project, NASA Advanced Supercomputing Division

    2016-06-01

    Flux-Level Transit Injection (FLTI) experiments are executed with NASA's Pleiades supercomputer for the Kepler Mission. The latest release (9.3, January 2016) of the Kepler Science Operations Center Pipeline is used in the FLTI experiments. Their purpose is to validate the Analytic Completeness Model (ACM), which can be computed for all Kepler target stars, thereby enabling exoplanet occurrence rate studies. Pleiades, a facility of NASA's Advanced Supercomputing Division, is one of the world's most powerful supercomputers and represents NASA's state-of-the-art technology. We discuss the details of implementing the FLTI experiments on the Pleiades supercomputer. For example, taking into account that ~16 injections are generated by one core of the Pleiades processors in an hour, the “shallow” FLTI experiment, in which ~2000 injections are required per target star, can be done for 16% of all Kepler target stars in about 200 hours. Stripping down the transit search to bare bones, i.e. only searching adjacent high/low periods at high/low pulse durations, makes the computationally intensive FLTI experiments affordable. The design of the FLTI experiments and the analysis of the resulting data are presented in “Validating an Analytic Completeness Model for Kepler Target Stars Based on Flux-level Transit Injection Experiments” by Catanzarite et al. (#2494058).Kepler was selected as the 10th mission of the Discovery Program. Funding for the Kepler Mission has been provided by the NASA Science Mission Directorate.

  3. Simultaneous algae-polluted water treatment and electricity generation using a biocathode-coupled electrocoagulation cell (bio-ECC).

    Science.gov (United States)

    Dong, Yue; Qu, Youpeng; Li, Chao; Han, Xiaoyu; Ambuchi, John J; Liu, Junfeng; Yu, Yanling; Feng, Yujie

    2017-10-15

    How to utilize electrocoagulation (EC) technology for algae-polluted water treatment in an energy-efficient manner remains a critical challenge for its widespread application. Herein, a novel biocathode-coupled electrocoagulation cell (bio-ECC) with sacrificial iron anode and nitrifying biocathode was developed. Under different solution conductivities (2.33±0.25mScm -1 and 4.94±0.55mScm -1 ), the bio-ECC achieved almost complete removal of algae cells. The maximum power densities of 8.41 and 11.33Wm -3 at corresponding current densities of 48.03Am -3 and 66.26Am -3 were obtained, with the positive energy balance of 4.52 and 7.44Wm -3 . In addition, the bio-ECC exhibited excellent NH 4 + -N removal performance with the nitrogen removal rates of 7.28mgL -1 h -1 and 6.77mgL -1 h -1 in cathode chamber, indicating the superiority of bio-ECC in NH 4 + -N removal. Pyrosequencing revealed that nitrifiers including Nitrospira, Nitrobacter, Nitrosococcus, and Nitrosomonas were enriched in biocathode. The removal mechanisms of algae in anode chamber were also explored by AFM and SEM-EDX tests. These results provide a proof-of-concept study of transferring energy-intensive EC process into an energy-neutral process with high-efficiency algae removal and electricity recovery. Copyright © 2017. Published by Elsevier B.V.

  4. Using ECC DRAM to Adaptively Increase Memory Capacity

    OpenAIRE

    Luo, Yixin; Ghose, Saugata; Li, Tianshi; Govindan, Sriram; Sharma, Bikash; Kelly, Bryan; Boroumand, Amirali; Mutlu, Onur

    2017-01-01

    Modern DRAM modules are often equipped with hardware error correction capabilities, especially for DRAM deployed in large-scale data centers, as process technology scaling has increased the susceptibility of these devices to errors. To provide fast error detection and correction, error-correcting codes (ECC) are placed on an additional DRAM chip in a DRAM module. This additional chip expands the raw capacity of a DRAM module by 12.5%, but the applications are unable to use any of this extra c...

  5. Preestrita pihtimus : Friedrich Nietzsche ja tema substantsiaalne mina (Ecce homo) / Jaan Undusk

    Index Scriptorium Estoniae

    Undusk, Jaan, 1958-

    1998-01-01

    Varem ilmunud raamatu järelsõnana: Nietzsche, Friedrich. Ecce homo : kuidas saadakse selleks, mis ollakse / tlk. Jaan Undusk. Tallinn : Vagabund, 1996. Sisu: Poeetiline, filosoofiline, dionüüsiline kaanon ; Künism contra hulluskahtlus ; Antikristlik pihtimus ; Egoretoorika

  6. Predictive Eco-Cruise Control (ECC) system : model development, modeling and potential benefits.

    Science.gov (United States)

    2013-02-01

    The research develops a reference model of a predictive eco-cruise control (ECC) system that intelligently modulates vehicle speed within a pre-set speed range to minimize vehicle fuel consumption levels using roadway topographic information. The stu...

  7. Parametric study of the potential for BWR ECCS strainer blockage due to LOCA generated debris. Final report

    International Nuclear Information System (INIS)

    Zigler, G.; Brideau, J.; Rao, D.V.; Shaffer, C.; Souto, F.; Thomas, W.

    1995-10-01

    This report documents a plant-specific study for a BWR/4 with a Mark I containment that evaluated the potential for LOCA generated debris and the probability of losing long term recirculation capability due ECCS pump suction strainer blockage. The major elements of this study were: (1) acquisition of detailed piping layouts and installed insulation details for a reference BWR; (2) analysis of plant specific piping weld failure probabilities to estimate the LOCA frequency; (3) development of an insulation and other debris generation and drywell transport models for the reference BWR; (4) modeling of debris transport in the suppression pool; (5) development of strainer blockage head loss models for estimating loss of NPSH margin; (6) estimation of core damage frequency attributable to loss of ECCS recirculation capability following a LOCA. Elements 2 through 5 were combined into a computer code, BLOCKAGE 2.3. A point estimate of overall DEGB pipe break frequency (per Rx-year) of 1.59E-04 was calculated for the reference plant, with a corresponding overall ECCS loss of NPSH frequency (per Rx-year) of 1.58E-04. The calculated point estimate of core damage frequency (per Rx-year) due to blockage related accident sequences for the reference BWR ranged from 4.2E-06 to 2.5E-05. The results of this study show that unacceptable strainer blockage and loss of NPSH margin can occur within the first few minutes after ECCS pumps achieve maximum flows when the ECCS strainers are exposed to LOCA generated fibrous debris in the presence of particulates (sludge, paint chips, concrete dust). Generic or unconditional extrapolation of these reference plant calculated results should not be undertaken

  8. Failure Mode and Effects Analysis (FMEA) of the Emergency Core Cooling System (ECCS) for a Westinghouse type 312, three loop pressurized water reactor

    International Nuclear Information System (INIS)

    Shopsky, W.E.

    1977-01-01

    The Emergency Core Cooling System (ECCS) is a Safeguards System designed to cool the core in the unlikely event of a Loss-of-Coolant Accident (LOCA) in the primary reactor coolant system as well as to provide additional shutdown capability following a steam break accident. The system is designed for a high reliability of providing emergency coolant and shutdown reactivity to the core for all anticipated occurrences of such accidents. The ECCS by performing its intended function assures that fuel and clad damage is minimized during accident conditions thus reducing release of fission products from the fuel. The ECCS is designed to perform its function despite sustaining a single failure by the judicious use of equipment and flow path redundancy within and outside the containment structure. By the use of an analytic tool, a Failure Mode and Effects Analysis (FMEA), it is shown that the ECCS is in compliance with the Single Failure Criterion established for active failures of fluid systems during short and long term cooling of the reactor core following a LOCA or steam break accident. An analysis was also performed with regards to passive failure of ECCS components during long-term cooling of the core following an accident. The design of the ECCS was verified as being able to tolerate a single passive failure during long-term cooling of the reactor core following an accident. The FMEA conducted qualitatively demonstrates the reliability of the ECCS (concerning active components) to perform its intended safety function

  9. Passive safety injection experiments and analyses (PAHKO)

    International Nuclear Information System (INIS)

    Tuunanen, J.

    1998-01-01

    PAHKO project involved experiments on the PACTEL facility and computer simulations of selected experiments. The experiments focused on the performance of Passive Safety Injection Systems (PSIS) of Advanced Light Water Reactors (ALWRs) in Small Break Loss-Of-Coolant Accident (SBLOCA) conditions. The PSIS consisted of a Core Make-up Tank (CMT) and two pipelines (Pressure Balancing Line, PBL, and Injection Line, IL). The examined PSIS worked efficiently in SBLOCAs although the flow through the PSIS stopped temporarily if the break was very small and the hot water filled the CMT. The experiments demonstrated the importance of the flow distributor in the CMT to limit rapid condensation. The project included validation of three thermal-hydraulic computer codes (APROS, CATHARE and RELAP5). The analyses showed the codes are capable to simulate the overall behaviour of the transients. The detailed analyses of the results showed some models in the codes still need improvements. Especially, further development of models for thermal stratification, condensation and natural circulation flow with small driving forces would be necessary for accurate simulation of the PSIS phenomena. (orig.)

  10. Development of CANDU ECCS performance evaluation methodology and guides

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Kwang Hyun; Park, Kyung Soo; Chu, Won Ho [Korea Maritime Univ., Jinhae (Korea, Republic of)

    2003-03-15

    The objectives of the present work are to carry out technical evaluation and review of CANDU safety analysis methods in order to assist development of performance evaluation methods and review guides for CANDU ECCS. The applicability of PWR ECCS analysis models are examined and it suggests that unique data or models for CANDU are required for the following phenomena: break characteristics and flow, frictional pressure drop, post-CHF heat transfer correlations, core flow distribution during blowdown, containment pressure, and reflux rate. For safety analysis of CANDU, conservative analysis or best estimate analysis can be used. The main advantage of BE analysis is a more realistic prediction of margins to acceptance criteria. The expectation is that margins demonstrated with BE methods would be larger that when a conservative approach is applied. Some outstanding safety analysis issues can be resolved by demonstration that accident consequences are more benign than previously predicted. Success criteria for analysis and review of Large LOCA can be developed by top-down approach. The highest-level success criteria can be extracted from C-6 and from them, the lower level criteria can be developed step-by-step, in a logical fashion. The overall objectives for analysis and review are to verify radiological consequences and frequency are met.

  11. Disease Management of Early Childhood Caries: ECC Collaborative Project

    Directory of Open Access Journals (Sweden)

    Man Wai Ng

    2014-01-01

    Full Text Available Until recently, the standard of care for early childhood caries (ECC has been primarily surgical and restorative treatment with little emphasis on preventing and managing the disease itself. It is now recognized that surgical treatment alone does not address the underlying etiology of the disease. Despite costly surgeries and reparative treatment, the onset and progression of caries are likely to continue. A successful rebalance of risk and protective factors may prevent, slow down, or even arrest dental caries and its progression. An 18-month risk-based chronic disease management (DM approach to address ECC in preschool children was implemented as a quality improvement (QI collaborative by seven teams of oral health care providers across the United States. In the aggregate, fewer DM children experienced new cavitation, pain, and referrals to the operating room (OR for restorative treatment compared to baseline historical controls. The teams found that QI methods facilitated adoption of the DM approach and resulted in improved care to patients and better outcomes overall. Despite these successes, the wide scale adoption and spread of the DM approach may be limited unless health policy and payment reforms are enacted to compensate providers for implementing DM protocols in their practice.

  12. Preliminary pellet injection experiment in the Gamma 10 tandem mirror

    Energy Technology Data Exchange (ETDEWEB)

    Kawamori, Eiichirou; Tamano, Teruo; Nakashima, Yousuke; Yoshikawa, Masayuki; Kobayashi, Shinji; Cho, Teruji; Ishii, Kameo; Yatsu, Kiyoshi [Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki (Japan); Mase, Atsushi [Advanced Sceince and Technology Center for Cooperative Research, Kyushu University, Kasuga, Fukuoka (Japan)

    2000-07-01

    In the GAMMA 10 tandem mirror, pellet injection experiments have been started as a solution for the density limit problem. This is the first pellet injection experiment in open systems. We describe the possibilities of confinement of pellet fueled particles. For that, we measure the number of end loss particles and compare them with pellet fueled ones in various conditions of confining potentials. The deterioration of confining potential with the pellet injection is a fundamental issue. The results show that the ion confining potential recover faster than central electron temperature due to thermal barrier. We also consider the operating space for fueling method. It is demonstrated that the operating space for pellet injection exceeds gas fueled one on hot ion mode plasmas. (author)

  13. ECCS analysis of B and W's 177-FA lowered-loop NSS

    International Nuclear Information System (INIS)

    Jones, R.C.; Biller, J.R.; Dunn, B.M.

    1975-06-01

    The effectiveness for the ECCS for B and W's 177-FA Lowered-Loop NSS is shown to meet the five criteria of 10 CFR 50.46. A spectrum analysis is performed and the worst case is used to establish allowable linear heat rates as a function of elevation in the core. (U.S.)

  14. Investigation of break location effects on thermal-hydraulics during intermediate break loss-of-coolant accident experiments at ROSA-III

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Tasaka, Kanji

    1986-01-01

    The rig of safety assessment (ROSA)-III facility is a volumetrically scaled (1/424) boiling water reactor (BWR/6) system with an electrically heated core designed for integral loss-of-coolant accident (LOCA) and emergency core cooling system (ECCS) tests. Break location effects on thermal-hydraulics during intermediate LOCAs were investigated by using four experiments at the ROSA-III, the 15 and 25 % main recirculation pump suction line break (MRPS-B) experiments, the 21 % single-ended jet pump drive line break (JPD-B) experiment and the 15 % main steam line break (MSL-B) experiment. Water injection from the high pressure core spray (HPCS) was not used in any of the experiments. Failure of ECCS actuation by the high containment pressure was also assumed in the tests. In the MRPS-B experiments, the discharge flow turned from low quality fluid to high quality fluid when the downcomer water level dropped to the main recirculation line outlet elevation, which suppressed coolant loss from the vessel and the core. In the JPD-B experiment, the jet pump drive nozzle was covered with low quality fluid and low quality fluid discharge continued even after the downcomer water level reached the jet pump suction elevation. Low quality fluid discharge ceased after the ADS actuation. It suggestes that the JPD-B LOCA has the possibility of causing larger and more severe core dryout and cladding temperature excursion than the MRPS-B LOCA. The MSL-B LOCA was characterized by mixture level swell in the downcomer and the core. The core mixture level swell resulted in the much later core dryout initiation than that in the MRPS-B LOCA, however, ECCS actuation was also delayed because of slow downcomer water level drop. (author)

  15. Study of Impact Damage in PVA-ECC Beam under Low-Velocity Impact Loading Using Piezoceramic Transducers and PVDF Thin-Film Transducers.

    Science.gov (United States)

    Qi, Baoxin; Kong, Qingzhao; Qian, Hui; Patil, Devendra; Lim, Ing; Li, Mo; Liu, Dong; Song, Gangbing

    2018-02-24

    Compared to conventional concrete, polyvinyl alcohol fiber reinforced engineering cementitious composite (PVA-ECC) offers high-strength, ductility, formability, and excellent fatigue resistance. However, impact-induced structural damage is a major concern and has not been previously characterized in PVA-ECC structures. We investigate the damage of PVA-ECC beams under low-velocity impact loading. A series of ball-drop impact tests were performed at different drop weights and heights to simulate various impact energies. The impact results of PVA-ECC beams were compared with mortar beams. A combination of polyvinylidene fluoride (PVDF) thin-film sensors and piezoceramic-based smart aggregate were used for impact monitoring, which included impact initiation and crack evolution. Short-time Fourier transform (STFT) of the signal received by PVDF thin-film sensors was performed to identify impact events, while active-sensing approach was utilized to detect impact-induced crack evolution by the attenuation of a propagated guided wave. Wavelet packet-based energy analysis was performed to quantify failure development under repeated impact tests.

  16. Disruption mitigation experiment with massive gas injection of HT-7

    International Nuclear Information System (INIS)

    Zhuang Huidong; Zhang Xiaodong

    2013-01-01

    Massive gas injection (MGI) is a promising method on disruption mitigation. The working principle of the fast valve for disruption mitigation was introduced. The disruption mitigation experiments by MGI on HT-7 were described. The experiment shows that the impurities radiation is improved by injecting appropriate amount of gas, and the current quench rate is slow down, so the electromagnetic load on the device is mitigated. The experiments show that the fast valve can completely satisfy the requirement of disruption mitigation on HT-7. (authors)

  17. Analysis and prevention of water hammer for the emergency core cooling system

    International Nuclear Information System (INIS)

    Zhao Jun

    2008-01-01

    Emergency core cooling system (ECCS) is an engineered safety feature of nuclear power plant. If the water hammer happens during ECCS injection, the piping system may be broken. It will cause loss of ECC system and affect the safety of reactor core. Based on the functions and characteristics of ECCS and the theory of water hammer, the paper analyzed the potential risk of water hammer in ECCS in Qinshan III, and proposed modifications to prevent the water-hammer damage during ECCS injection. (authors)

  18. FPGA implementation of PCI to CAMAC interface for Embedded CAMAC Controller (ECC)

    International Nuclear Information System (INIS)

    Jha, K.; Behere, Anita; Ghodgaonkar, M.D.

    2005-01-01

    CAMAC controllers are used for control systems and nuclear physics experiments. Control applications need more number of physically distributed crates with regular scanning of all the parameters, the control being with a centralized computer. On the other hand, nuclear physics experiments need a high throughput with a large number of parameters in one or more crates. The nature of events is random hence buffering of data in LIST mode acquisition is needed. For a large number of parameters, this translates to high transfer rate. Hence it is essential that the CAMAC readout time is minimized and also the data transfer speed is improved to achieve maximum effective throughput. The ECC is designed to achieve these objectives using an embedded controller with PC architecture having PCI bus as interface for add on logic. The PCI Add-on to CAMAC interface protocol has been implemented in an AL TERA FPGA and all the functionality coded in VHDL. This paper discusses the design aspects of the FPGA implementation of the PCI to CAMAC interface. (author)

  19. Experiments on Li pellet injection into Heliotron E

    International Nuclear Information System (INIS)

    Sergeev, V.Yu.; Khlopenkov, K.V.; Kuteev, B.V.; Sudo, S.; Kondo, K.; Zushi, H.; Besshou, S.; Sano, F.; Okada, H.; Mizuuchi, T.; Nagasaki, K.; Obiki, T.; Kurimoto, Y.

    1998-01-01

    Li pellets of large size were injected into electron cyclotron resonance (ECR) heated plasmas and neutral beam injection (NBI) heated plasmas of Heliotron E. The discharge behaviour, pellet ablation and wall conditioning were studied. The electron pressure is doubled after injection into the NBI plasma and remains unchanged in the case of ECR heating. This may be due to the energy exchange between the electrons and thermal ions with the fast ions from the neutral beam. The observed discrepancy between the experimental and modelled ablation rates may be caused by both the plasma cooling due to pellet ablatant and the ablation stimulated by the fast ions in the NBI-heated regime and by the fast electrons in the ECR-heated regime. In preliminary experiments on wall conditioning by Li pellet injection, no improvement of plasma performance after Li pellet injection was observed in the divertor or limiter configuration, with the limiter radii r L =24-25cm. (author)

  20. Experiment data report for semiscale Mod-1 test S-01-1B (isothermal blowdown with core resistance simulator)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Jensen, M.F.; Sackett, K.E.; Zender, S.N.

    1975-05-01

    Recorded test data are presented for Test S-01-1B of the semiscale Mod-1 isothermal blowdown test series. System hardware is representative of the LOFT design, selected using volumetric scaling methods, and initial conditions duplicate those identified for the LOFT nonnuclear tests. Test S-01-1B is a repeat of Test S-01-1 with the exception that simulated ECC was injected into the cold leg of the intact loop rather than into the inlet annulus of the downcomer. The principal objective of Test S-01-1B was to determine whether a different ECC injection would significantly alter the system response during the period of ECC injection. Test S-01-1B was conducted from an initial temperature of 541 0 F and an initial pressure of 1630 psig. A simulated intermediate size double-ended hot leg break (0.00145 ft 2 break area on each end) was used to investigate the system response to a slow de-pressurization transient. An orificed structure was used in the pressure vessel to simulate the LOFT core simulator. Following the blowdown portion of Test S-01-1B, coolant spray was introduced into the pressure suppression tank to determine the response of the pressure suppression system. (U.S.)

  1. Pellet injection experiments on tokamaks in ASIPP, China

    International Nuclear Information System (INIS)

    Yang, Y.; Bao, Y.; Li, J.; Gu, X.; He, Y.

    1999-01-01

    Pellet Injection has been proven to be an effective method for deep fuelling of fusion devices. Improvements of both the particle confinement and the energy confinement were observed in many experiments. In HT-6M and HT-7 tokamaks, single and multi-pellet experiments are tried, and attractive results are obtained

  2. Designing Fault-Injection Experiments for the Reliability of Embedded Systems

    Science.gov (United States)

    White, Allan L.

    2012-01-01

    This paper considers the long-standing problem of conducting fault-injections experiments to establish the ultra-reliability of embedded systems. There have been extensive efforts in fault injection, and this paper offers a partial summary of the efforts, but these previous efforts have focused on realism and efficiency. Fault injections have been used to examine diagnostics and to test algorithms, but the literature does not contain any framework that says how to conduct fault-injection experiments to establish ultra-reliability. A solution to this problem integrates field-data, arguments-from-design, and fault-injection into a seamless whole. The solution in this paper is to derive a model reduction theorem for a class of semi-Markov models suitable for describing ultra-reliable embedded systems. The derivation shows that a tight upper bound on the probability of system failure can be obtained using only the means of system-recovery times, thus reducing the experimental effort to estimating a reasonable number of easily-observed parameters. The paper includes an example of a system subject to both permanent and transient faults. There is a discussion of integrating fault-injection with field-data and arguments-from-design.

  3. Mechanical interaction of Engineered Cementitious Composite (ECC) reinforced with Fiber Reinforced Polymer (FRP) rebar in tensile loading

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2010-01-01

    This paper introduces a preliminary study of the composite interaction of Engineered Cementitious Composite (ECC), reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar. The main topic of this paper will focus on the interaction of the two materials (ECC and GFRP) during axial loading......, particularly in post cracking phase of the concrete matrix. The experimental program carried out in this study examined composite behavior under monotonic and cyclic loading of the specimens in the elastic and inelastic deformation phases. The stiffness development of the composite during loading was evaluated...

  4. Pellet injection experiments on tokamaks in ASIPP, China

    International Nuclear Information System (INIS)

    Yang, Y.; Bao, Y.; Li, J.; Gu, X.; He, Y.

    2001-01-01

    Pellet injection has been proved to be an effective method for deep fueling of fusion devices. Improvements of both the particle confinement and the energy confinement were observed in many experiments. In HT-6M and HT-7 tokamaks, single and multi-pellet experiments are tried, and attractive results are obtained. (author)

  5. Comparison of allele frequency for HLA-DR and HLA-DQ between patients with ECC and caries-free children

    OpenAIRE

    Bagherian A; Nematollahi H; Afshari J; Moheghi N

    2008-01-01

    Background: Early childhood caries (ECC) is one of the most common diseases of childhood. The etiology of ECC is multifactorial and both genetic and environmental factors play important roles in the pathogenesis of the disease. Genetic variations in the hosts may contribute to changes in the risk for dental caries. Genetic factors such as human leukocyte antigen (HLA) have recently been suggested as a predisposing factor. Aim: The aim of this study was to look for an association between HLA-D...

  6. Factors predisposing to early childhood caries (ECC) in children of pre-school age in the city of Zagreb, Croatia.

    Science.gov (United States)

    Lulić-Dukić, O; Jurić, H; Dukić, W; Glavina, D

    2001-06-01

    The aim of this study was to investigate factors predisposing to early childhood caries (ECC) in pre-school children in the city of Zagreb, Croatia. The investigation was carried out on the sample of 145 children (77 boys and 68 girls) aged between 2 and 5 years, including clinical examination of dental status and survey on the habits among the parents. The overall prevalence of ECC was 30%: in girls it was 25%, and in boys 48%. The study on the risk factors was designed as a classic case-control study. The mean value of dmfs index among the cases amounted to 8.6, in comparison to 5.2 in the control group (pteeth-brushing habit after first 24 months did (p importance of early introduction of teeth-brushing and giving up the nightly consumption of sweet beverages in prevention of ECC.

  7. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  8. A provably-secure ECC-based authentication scheme for wireless sensor networks.

    Science.gov (United States)

    Nam, Junghyun; Kim, Moonseong; Paik, Juryon; Lee, Youngsook; Won, Dongho

    2014-11-06

    A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme) is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000). Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC), and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure) schemes.

  9. A Provably-Secure ECC-Based Authentication Scheme for Wireless Sensor Networks

    Science.gov (United States)

    Nam, Junghyun; Kim, Moonseong; Paik, Juryon; Lee, Youngsook; Won, Dongho

    2014-01-01

    A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme) is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000). Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC), and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure) schemes. PMID:25384009

  10. A Provably-Secure ECC-Based Authentication Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Junghyun Nam

    2014-11-01

    Full Text Available A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000. Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC, and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure schemes.

  11. Assessment of some interfacial shear correlations in a model of ECC bypass flow in PWR reactor downcomer

    International Nuclear Information System (INIS)

    Popov, N.K.; Rohatgi, U.S.

    1987-01-01

    The bypass/refill process in the PWR reactor downcomer, following a large rupture of a cold leg coolant supply pipe, is a complicated thermo-hydraulic two-phase flow phenomenon. Mathematical modeling of such phenomena is always accompanied with a difficult task of selection of suitable constitutive correlations. In a typically hydrodynamic phenomenon, like ECC refill process of the reactor lower plenum is considered, the phasic interfacial friction is the most influential constitutive correlation. Therefore, assessment of the well-known widely-used interfacial friction constitutive correlations in the model of ECC bypass/refill process, is the subject of this paper

  12. The E.C.C. programme in the field of radioactive wastes

    International Nuclear Information System (INIS)

    Orlowski, S.

    1976-01-01

    After a description of the aims of the E.C.C. in the field of radioactive wastes, the contents and the structure of the programme developed for this purpose as well as its time schedule and financing, are presented. The state of work progress and the first results of the actions taken, whose application is marked by an active cooperation of numerous national experts are quoted [fr

  13. Modifying the ECC-based grouping-proof RFID system to increase inpatient medication safety.

    Science.gov (United States)

    Ko, Wen-Tsai; Chiou, Shin-Yan; Lu, Erl-Huei; Chang, Henry Ker-Chang

    2014-09-01

    RFID technology is increasingly used in applications that require tracking, identification, and authentication. It attaches RFID-readable tags to objects for identification and execution of specific RFID-enabled applications. Recently, research has focused on the use of grouping-proofs for preserving privacy in RFID applications, wherein a proof of two or more tags must be simultaneously scanned. In 2010, a privacy-preserving grouping proof protocol for RFID based on ECC in public-key cryptosystem was proposed but was shown to be vulnerable to tracking attacks. A proposed enhancement protocol was also shown to have defects which prevented proper execution. In 2012, Lin et al. proposed a more efficient RFID ECC-based grouping proof protocol to promote inpatient medication safety. However, we found this protocol is also vulnerable to tracking and impersonation attacks. We then propose a secure privacy-preserving RFID grouping proof protocol for inpatient medication safety and demonstrate its resistance to such attacks.

  14. Experiments on Plume Spreading by Engineered Injection and Extraction

    Science.gov (United States)

    Mays, D. C.; Jones, M.; Tigera, R. G.; Neupauer, R.

    2014-12-01

    The notion that groundwater remediation is transport-limited emphasizes the coupling between physical (i.e., hydrodynamic), geochemical, and microbiological processes in the subsurface. Here we leverage this coupling to promote groundwater remediation using the approach of engineered injection and extraction. In this approach, inspired by the literature on chaotic advection, uncontaminated groundwater is injected and extracted through a manifold of wells surrounding the contaminated plume. The potential of this approach lies in its ability to actively manipulate the velocity field near the contaminated plume, generating plume spreading above and beyond that resulting from aquifer heterogeneity. Plume spreading, in turn, promotes mixing and reaction by chemical and biological processes. Simulations have predicted that engineered injection and extraction generates (1) chaotic advection whose characteristics depend on aquifer heterogeneity, and (2) faster rates and increased extent of groundwater remediation. This presentation focuses on a complimentary effort to experimentally demonstrate these predictions experimentally. In preparation for future work using refractive index matched (RIM) porous media, the experiments reported here use a Hele-Shaw apparatus containing silicone oil. Engineered injection and extraction is used to manipulate the geometry of an initially circular plume of black pigment, and photographs record the plume geometry after each step of injection of extraction. Image analysis, using complimentary Eulerian and Lagrangian approaches, reveals the thickness and variability of the dispersion zone surrounding the deformed plume of black pigment. The size, shape, and evolution of this dispersion zone provides insight into the interplay between engineered injection and extraction, which generates plume structure, and dispersion (here Taylor dispersion), which destroys plume structure. These experiments lay the groundwork for application of engineered

  15. Air-water mixing experiments for direct vessel injection of KNGR

    International Nuclear Information System (INIS)

    Hwang, Do Hyun

    2000-02-01

    Two air-water mixing experiments are conducted to understand the flow behavior in the downcomer for Direct Vessel Injection (DVI) of Korean Next Generation Reactor (KNGR). In the first experiment which is an air-water experiment in the rectangular channel with the gap size of 1cm, the width of water film is proportional to the water and air velocities and the inclined angle is proportional to the water velocity only, regardless of the water velocity injected in the rectangular channel. It is observed that the amount of entrained water is negligible. In the second experiment which is a full-scaled water jetting experiment without air flow, the width of water film is proportional to the flow rate injected from the pipe exit and the film thickness of water varies from 1.0mm to 5.0mm, and the maximum thickness does not exceed 5.0mm. The amount of water separated from the liquid film after striking of water jetting on the wall is measured. The amount of separation water is proportional to the flow rate, but the separation ratio in the full-scaled water jetting is not over 15%. A simplified physical model, which is designed to predict the trajectories of the width of water film, is validated through the comparison with experiment results. The 13 .deg. upward water droplet of the water injected from the pipe constitutes the outermost boundary at 1.7m below from pipe level, after the water impinges against the wall. In the model, the parameter, η which represents the relationship between the jetting velocity and the initial spreading velocity, is inversely proportional to the water velocity when it impinges against the wall. The error of the predictions by the model is decreased within 14% to the experimental data through use of exponential fitting of η for the jetting water velocity

  16. Repetitive laser fusion experiment and operation using a target injection system

    International Nuclear Information System (INIS)

    Nishimura, Yasuhiko; Komeda, Osamu; Mori, Yoshitaka

    2017-01-01

    Since 2008, a collaborative research project on laser fusion development based on a high-speed ignition method using repetitive laser has been carried out with several collaborative research institutes. This paper reports the current state of operation of high repetition laser fusion experiments, such as target introduction and control based on a target injection system that allows free falling under 1 Hz, using a high repetition laser driver that has been under research and development, as well as the measurement of targets that freely fall. The HAMA laser driver that enabled high repetition fusion experiments is a titanium sapphire laser using a diode-pumped solid-state laser KURE-I of green light output as a driver pump light source. In order to carry out high repetition laser fusion experiments, the target injection device allows free falling of deuterated polystyrene solid sphere targets of 1 mm in diameter under 1 Hz. The authors integrated the developed laser and injection system, and succeeded first in the world in making the nuclear fusion reaction continuously by hitting the target to be injected with laser, which is essential technology for future laser nuclear fusion reactor. In order to realize repetition laser fusion experiments, stable laser, target synchronization control, and target position measurement technologies are indispensable. (A.O.)

  17. Initial Results from Coaxial Helicity Injection Experiments in NSTX

    International Nuclear Information System (INIS)

    Raman, R.; Jarboe, T.R.; Mueller, D.; Schaffer, M.J.; Maqueda, R.; Nelson, B.A.; Sabbagh, S.; Bell, M.; Ewig, R.; Fredrickson, E.; Gates, D.; Hosea, J.; Ji, H.; Kaita, R.; Kaye, S.M.; Kugel, H.; Maingi, R.; Menard, J.; Ono, M.; Orvis, D.; Paolette, F.; Paul, S.; Peng, M.; Skinner, C.H.; Wilgen, W.; Zweben, S.

    2001-01-01

    Coaxial Helicity Injection (CHI) has been investigated on the National Spherical Torus Experiment (NSTX). Initial experiments produced 130 kA of toroidal current without the use of the central solenoid. The corresponding injector current was 20 kA. Discharges with pulse lengths up to 130 ms have been produced

  18. ECCE Toolkit: Prototyping Sensor-Based Interaction

    Directory of Open Access Journals (Sweden)

    Andrea Bellucci

    2017-02-01

    Full Text Available Building and exploring physical user interfaces requires high technical skills and hours of specialized work. The behavior of multiple devices with heterogeneous input/output channels and connectivity has to be programmed in a context where not only the software interface matters, but also the hardware components are critical (e.g., sensors and actuators. Prototyping physical interaction is hindered by the challenges of: (1 programming interactions among physical sensors/actuators and digital interfaces; (2 implementing functionality for different platforms in different programming languages; and (3 building custom electronic-incorporated objects. We present ECCE (Entities, Components, Couplings and Ecosystems, a toolkit for non-programmers that copes with these issues by abstracting from low-level implementations, thus lowering the complexity of prototyping small-scale, sensor-based physical interfaces to support the design process. A user evaluation provides insights and use cases of the kind of applications that can be developed with the toolkit.

  19. First neutral beam injection experiments on KSTAR tokamaka)

    Science.gov (United States)

    Jeong, S. H.; Chang, D. H.; Kim, T. S.; In, S. R.; Lee, K. W.; Jin, J. T.; Chang, D. S.; Oh, B. H.; Bae, Y. S.; Kim, J. S.; Park, H. T.; Watanabe, K.; Inoue, T.; Kashiwagi, M.; Dairaku, M.; Tobari, H.; Hanada, M.

    2012-02-01

    The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D+:D2+:D3+ = 75:20:5 at beam current density of 85 mA/cm2. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the Ti and Te profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

  20. Factors Predisposing to Early Childhood Caries (ECC) in Children of Pre-School Age in the City of Zagreb, Croatia

    OpenAIRE

    Lulić-Dukić, O.; Jurić, H.; Dukić, W.; Glavina, D.

    2001-01-01

    The aim of this study was to investigate factors predisposing to early childhood caries (ECC) in pre-school children in the city of Zagreb, Croatia. The investigation was carried out on the sample of 145 children (77 boys and 68 girls) aged between 2 and 5 years, including clinical examination of dental status and survey on the habits among the parents. The overall prevalence of ECC was 30%: in girls it was 25%, and in boys 48%. The study on the risk factors was designed as a c...

  1. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1978-05-01

    Of the total 10 ROSA-II/UHI performance tests, 6 were reported previously. The rest are presented and discussion is made on the effects of heat generation in the core and UHI injection and repeatability of experiments. In addition, the following are described: (1) Pressure spikes observed in the upper head after sudden stoppage of UHI injection, and (2) discharge flow oscillation possibly due to UHI water injection into the upper plenum. (auth.)

  2. Adapted ECC ozonesonde for long-duration flights aboard boundary-layer pressurised balloons

    Science.gov (United States)

    Gheusi, François; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clenet, Antoine; Derrien, Solène; Doerenbecher, Alexis; El Amraoui, Laaziz; Fontaine, Alain; Hache, Emeric; Jambert, Corinne; Jaumouillé, Elodie; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore

    2016-12-01

    Since the 1970s, the French space agency CNES has developed boundary-layer pressurised balloons (BLPBs) with the capability to transport lightweight scientific payloads at isopycnic level and offer a quasi-Lagrangian sampling of the lower atmosphere over very long distances and durations (up to several weeks).Electrochemical concentration cell (ECC) ozonesondes are widely used under small sounding balloons. However, their autonomy is limited to a few hours owing to power consumption and electrolyte evaporation. An adaptation of the ECC sonde has been developed specifically for long-duration BLPB flights. Compared to conventional ECC sondes, the main feature is the possibility of programming periodic measurement sequences (with possible remote control during the flight). To increase the ozonesonde autonomy, the strategy has been adopted of short measurement sequences (2-3 min) regularly spaced in time (e.g. every 15 min). The rest of the time, the sonde pump is turned off. Results of preliminary ground-based tests are first presented. In particular, the sonde was able to provide correct ozone concentrations against a reference UV-absorption ozone analyser every 15 min for 4 days. Then we illustrate results from 16 BLBP flights launched over the western Mediterranean during three summer field campaigns of the ChArMEx project (http://charmex.lsce.ipsl.fr): TRAQA in 2012, and ADRIMED and SAFMED in 2013. BLPB drifting altitudes were in the range 0.25-3.2 km. The longest flight lasted more than 32 h and covered more than 1000 km. Satisfactory data were obtained when compared to independent ozone measurements close in space and time. The quasi-Lagrangian measurements allowed a first look at ozone diurnal evolution in the marine boundary layer as well as in the lower free troposphere. During some flight segments, there was indication of photochemical ozone production in the marine boundary layer or even in the free troposphere, at rates ranging from 1 to 2 ppbv h -1, which

  3. First neutral beam injection experiments on KSTAR tokamak.

    Science.gov (United States)

    Jeong, S H; Chang, D H; Kim, T S; In, S R; Lee, K W; Jin, J T; Chang, D S; Oh, B H; Bae, Y S; Kim, J S; Park, H T; Watanabe, K; Inoue, T; Kashiwagi, M; Dairaku, M; Tobari, H; Hanada, M

    2012-02-01

    The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1∕3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D(+):D(2)(+):D(3)(+) = 75:20:5 at beam current density of 85 mA/cm(2). The arc efficiency is more than 1.0 A∕kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the T(i) and T(e) profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

  4. Experiment HFR-B1: A preliminary analysis of the water-vapor injection experiments in capsule 3

    International Nuclear Information System (INIS)

    Myers, B.F.

    1993-01-01

    A preliminary analysis of the response of uranium oxycarbide (UCO) fuel to water vapor addition in capsule 3 of experiment HFR-B1 (HFR-B1/3) has been conducted. The analysis provides an early indication of the behavior of fission gas release under a wider range of water-vapor pressures and of temperatures than heretofore studied. A preliminary analysis of selected aspects of the water-vapor injection tests in capsule 3 of experiment HFR-B1 is presented. The release of fission gas stored in bubbles and the diffusive release of fission-gas atoms are distinguished. The dependence of the release of stored fission gas ( 85m Kr) on water-vapor pressure, P(H 2 O), and temperature were established taking into account the contributing mechanisms of gaseous release, the effect of graphite hydrolysis, and the requirement of consistency with experiment HRB-17 in which similar water-vapor injection tests were conducted. The dependence on P(H 2 O) becomes weaker as temperatures increase above 770 degree C; the activation energy for release of stored-fission gas is 393 kJ/mol. Isorelease curves for the pressure-temperature plane were deduced from a derived functional relation. The stored-fission gas releases as a function of P(H 2 O) at a common temperature for experiments HFR-B1 and HRB-17 differ by a factor of 4; this discrepancy could be attributed to the differences in fission-rate density and neutron flux between the two experiments. Diffusive release of fission gas occurred during and after the release of stored gas. The ratio of diffusive release during water-vapor injection to that prior to injection varied in contrast to the results from HRB-17. The variation was attributed to the practice of injecting water vapor into HFR-B1 before sintering of the fuel, hydrolyzed in the previous test, was completed. The derived activation energy for diffusive release is 23.6 kJ/mol

  5. Experiment HFR-B1: A preliminary analysis of the water-vapor injection experiments in capsule 3

    Energy Technology Data Exchange (ETDEWEB)

    Myers, B.F.

    1993-08-01

    A preliminary analysis of the response of uranium oxycarbide (UCO) fuel to water vapor addition in capsule 3 of experiment HFR-B1 (HFR-B1/3) has been conducted. The analysis provides an early indication of the behavior of fission gas release under a wider range of water-vapor pressures and of temperatures than heretofore studied. A preliminary analysis of selected aspects of the water-vapor injection tests in capsule 3 of experiment HFR-B1 is presented. The release of fission gas stored in bubbles and the diffusive release of fission-gas atoms are distinguished. The dependence of the release of stored fission gas ({sup 85m}Kr) on water-vapor pressure, P(H{sub 2}O), and temperature were established taking into account the contributing mechanisms of gaseous release, the effect of graphite hydrolysis, and the requirement of consistency with experiment HRB-17 in which similar water-vapor injection tests were conducted. The dependence on P(H{sub 2}O) becomes weaker as temperatures increase above 770{degree}C; the activation energy for release of stored-fission gas is 393 kJ/mol. Isorelease curves for the pressure-temperature plane were deduced from a derived functional relation. The stored-fission gas releases as a function of P(H{sub 2}O) at a common temperature for experiments HFR-B1 and HRB-17 differ by a factor of 4; this discrepancy could be attributed to the differences in fission-rate density and neutron flux between the two experiments. Diffusive release of fission gas occurred during and after the release of stored gas. The ratio of diffusive release during water-vapor injection to that prior to injection varied in contrast to the results from HRB-17. The variation was attributed to the practice of injecting water vapor into HFR-B1 before sintering of the fuel, hydrolyzed in the previous test, was completed. The derived activation energy for diffusive release is 23.6 kJ/mol.

  6. MICROORGANISMS FOUND IN SECONDARY CATARACT MATERIAL OF ECCE PATIENTS, A STUDY WITH SEM AND TEM

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1993-01-01

    Globular secondary cataract material, removed from 24 patients with ECCE after ophthalmic cleaning of the anterior capsule, were investigated with SEM and TEM. Besides spherical, somewhat oval shaped bodies of various shape and size comparable with those found in cataractous lenses, (an)aerobic

  7. The first experiment of MPD Jet injection into GAMMA 10 plasma

    International Nuclear Information System (INIS)

    Ichimura, Kazuya; Nakashima, Yousuke; Takeda, Hisato

    2014-01-01

    Results of the first experiment of short pulse plasma injection by MPD (magneto plasma dynamic) Jet into GAMMA 10/PDX's longer pulse plasma are reported. In the experiment, a new method for plasma start-up without using plasma guns was applied. In this method, the main plasma of GAMMA 10/PDX was produced by ECRH (electron cyclotron resonance heating) and ICRF (ion cyclotron range of frequency). Then, MPD Jet plasma was injected into the main plasma along magnetic field line. As a result, density of the main plasma was increased and the end-loss flux was doubled. Flow velocity of the plasmoid injected by the MPD Jet was evaluated from the change of plasma density in each cell of the tandem mirror. The result indicated that the flow speed is several km/s. It is found that the plasmoid worked as strong fueling device which dramatically raises the density of plasma. Therefore injection of MPD Jet plasma into tandem mirror can be a useful tool to study physical phenomena of divertor and PWI. (author)

  8. Simulation of a large break loss of coolant (LBLOCA), without actuation of the emergency injection systems (ECCS) for a BWR-5; Simulacion de un escenario de perdida de refrigerante grande (LBLOCA), sin actuacion de los sistemas de inyeccion de emergencia (ECCS) para un reactor BWR-5

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Lopez M, R., E-mail: jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    In this paper the analysis of scenario for the loss of coolant case was realized with break at the bottom of a recirculation loop of a BWR-5 with containment type Mark II and a thermal power of 2317 MWt considering that not have coolant injection. This in order to observe the speed of progression of the accident, the phenomenology of the scenario, the time to reach the limit pressure of containment venting and the amount of radionuclides released into the environment. This simulation was performed using the MELCOR code version 2.1. The scenario posits a break in one of the shear recirculation loops. The emergency core cooling system (ECCS) and the reactor core isolation cooling (Rcic) have not credit throughout the event, which allowed achieve greater severity on scenario. The venting of the primary containment was conducted via valve of 30 inches instead of the line of 24 inches of wet well, this in order to have a larger area of exhaust of fission products directly to the reactor building. The venting took place when the pressure in the primary containment reached the 4.5 kg/cm{sup 2} and remained open for the rest of the scenario to maximize the amount released of radionuclides to the atmosphere. The safety relief valves were considered functional they do not present mechanical failure or limit their ability to release pressure due to the large number of performances in safety mode. The results of the analysis covers about 48 hours, time at which the accident evolution was observed; behavior of level, pressure in the vessel and the fuel temperature profile was analyzed. For progression of the scenario outside the vessel, the pressure and temperature of the primary containment, level and temperature of the suppression pool, the hydrogen accumulation in the container and the radionuclides mass released into the atmosphere were analyzed. (Author)

  9. Combined group ECC protection and subgroup parity protection

    Science.gov (United States)

    Gara, Alan G.; Chen, Dong; Heidelberger, Philip; Ohmacht, Martin

    2013-06-18

    A method and system are disclosed for providing combined error code protection and subgroup parity protection for a given group of n bits. The method comprises the steps of identifying a number, m, of redundant bits for said error protection; and constructing a matrix P, wherein multiplying said given group of n bits with P produces m redundant error correction code (ECC) protection bits, and two columns of P provide parity protection for subgroups of said given group of n bits. In the preferred embodiment of the invention, the matrix P is constructed by generating permutations of m bit wide vectors with three or more, but an odd number of, elements with value one and the other elements with value zero; and assigning said vectors to rows of the matrix P.

  10. Comprehensive Oral Health Care to Reduce the Incidence of Severe Early Childhood Caries (s-ECC) in Urban China.

    Science.gov (United States)

    Si, Yan; Guo, Yan; Yuan, Chao; Xu, Tao; Zheng, Shu Guo

    2016-03-01

    To explore the effectiveness of comprehensive oral health care to reduce the caries incidence for children with severe early childhood caries (s-ECC) in an urban area in China. A total of 357 children aged 3 to 4 years old and diagnosed with s-ECC were recruited in this randomised controlled, single-blinded clinical trial for 1 year. Children of two different kindergarten classes were enrolled in this study and randomly divided into a test group (205 children) and a control group (152 children). The test group received comprehensive oral health care, which included: oral health examination, oral health education, topical fluoride application and dental treatment, and the children in the control group only received the oral health examination. The evaluation of the oral health questionnaire for parents was also performed. An evaluation was carried out at the time of recruitment and 1 year later to explore the effectiveness of the comprehensive oral health care model. The differences in decayed teeth (dt), decayed tooth surfaces (ds), filled teeth (ft), filled tooth surfaces (fs) and the ratio of ft /(dt + ft) between the two groups were statistically significant (P comprehensive oral health care program reduces and prevents caries amongst children with s-ECC.

  11. Prosthetic Oral Rehabilitation of a Child With S-ECC: A Case Report with Histopathologic Analysis.

    Science.gov (United States)

    Tannure, P N; Moraes, G G; Borba, McU; Abrahão, A; Andrade, Mtrc; Fidalgo, Tks

    2015-01-01

    The aim of this case report is to describe the treatment planning of a young child with severe early childhood caries (S-ECC) as well as the prosthetic rehabilitation technique. A 3-year-old female child was referred to the pediatric dentistry clinic with the chief complaint of tooth pain, difficulty in eating and recurrent hospitalizations caused by dental infections. The mother reported intermittent episodes of fever and recurrent swelling of child's face. The girl presented angular cheilitis and was referred to a dietitian. The treatment plain consisted on a behavior changes in oral hygiene habits, exodontias of all primary teeth and oral rehabilitation with a prosthesis. The extracted teeth with periapical lesions were submitted to histopathologic analysis (hematoxilin and eosin staining) and revealed an inflammatory infiltrate. The aesthetic requirement of children with S-ECC has been a challenge to pediatric dentists. In the present case, the oral rehabilitation provided for the children better aesthetic, nutrition, phonation, and functional conditions.

  12. Engineering of the divertor injection tokamak experiment (DITE)

    International Nuclear Information System (INIS)

    Plummer, K.M.; Bayes, D.V.; Bell, D.; Burt, J.; Galloway, F.; Sanders, B.C.; Skelton, D.E.; Varley, G.L.

    1976-01-01

    The DITE assembly has been constructed to study the effect of powerful neutral injection and the use of magnetic divertors in Tokamak systems. In addition, the plasma is stabilized by a position controlled feed-back vertical field system developed from results on the CLEO experiment, and added to DITE later in the design stage. The machine is designed for an ultimate plasma current of 340 kA, having a minor radius of 23 cm at q = 2, on a major radius of 113 cm. The 28 kG Bphi field, from 16 liquid nitrogen cooled coils has a 2% ripple at the edge of the plasma. The divertor is a ''bundle'' type, the present design of which is limited to operating in a Bphi field of 18 kG. Neutral Injection, initially by two, and ultimately by four injectors, is intended to supply about 1,500 kW of beam power. The engineering is now complete and the machine commissioned; this paper describes the up-to-date design of the machine and includes some of our experiences during design, construction and commissioning

  13. Complete genome sequences of Escherichia coli strains 1303 and ECC-1470 isolated from bovine mastitis

    NARCIS (Netherlands)

    Leimbach, Andreas; Poehlein, Anja; Witten, Anika; Scheutz, Flemming; Schukken, Ynte|info:eu-repo/dai/nl/075051907; Daniel, Rolf; Dobrindt, Ulrich

    2016-01-01

    Escherichia coli is the leading causative agent of acute bovine mastitis. Here, we report the complete genome sequence of E. coli O70:H32 strain 1303, isolated from an acute case of bovine mastitis, and E. coli Ont:Hnt strain ECC-1470, isolated from a persistent infection.

  14. Impurity pellet injection experiments at TFTR

    International Nuclear Information System (INIS)

    Marmar, E.S.

    1991-01-01

    Impurity (Li and C) pellet experiments, which began at TFTR in 1989, and are expected to continue at least through 1991, have continued to produce new and significant results. The most significant of these are: (1) improvements in TFTR supershots after wall-conditioning by Li pellet injection; (2) accurate measurements of the pitch angle profiles of the internal magnetic field using the polarization angles of line emission from Li + in the pellet ablation cloud; and (3) initial measurements of pitch angle profiles using the tilt of the LI + emission region of the ablation cloud which is stretched out along the field lines

  15. Large break LOCA analysis for retrofitted ECCS at MAPS using modified computer code ATMIKA

    International Nuclear Information System (INIS)

    Singhal, Mukesh; Khan, T.A.; Yadav, S.K.; Pramod, P.; Rammohan, H.P.; Bajaj, S.S.

    2002-01-01

    Full text: Computer code ATMIKA which has been used for thermal hydraulic analysis is based on unequal velocity equal temperature (UVET) model. Thermal hydraulic transient was predicted using three conservation equations and drift flux model. The modified drift flux model is now able to predict counter current flow and the relative velocity in vertical channel more accurately. Apart from this, stratification model is also introduced to predict the fuel behaviour under stratified condition. Many more improvements were carried out with respect to solution of conservation equation, heat transfer package and frictional pressure drop model. All these modifications have been well validated with published data on RD-12/RD-14 experiments. This paper describes the code modifications and also deals with the application of the code for the large break LOCA analysis for retrofitted emergency core cooling system (ECCS) being implemented at Madras Atomic Power Station (MAPS). This paper also brings out the effect of accumulator on stratification and fuel behaviour

  16. Performance-based ECCS cladding acceptance criteria: A new simulation approach

    International Nuclear Information System (INIS)

    Zoino, A.; Alfonsi, A.; Rabiti, C.; Szilard, R.H.; Giannetti, F.; Caruso, G.

    2017-01-01

    Highlights: • A new methodology to demonstrate compliance with the new ECCS acceptance criteria is described. • A wide spectrum of fuel rod initial burnup states can be analysed in the design phase. • The coupled suite PHISICS/RELAP5-3D has been used in the analyses. • A demo simulation of the equilibrium cycle, load-following and a LOCA analysis has been performed. - Abstract: The U.S. Nuclear Regulatory Commission is currently proposing rulemaking to revise the Loss Of Coolant Accident (LOCA) and therefore the Emergency Core Cooling System (ECCS) acceptance criteria, to include the effects of higher burnup on cladding performance as well as to address other technical issues. As motivated by the new rule, the need to use advanced cladding designs may be a result. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost, as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently, there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin. The study here presented has been part of a big project used to investigate technical issues and approaches for future industrial applications within the Risk-Informed Safety Margin Characterization (RISMC) Pathway. Specifically, the primary aim of this study is to lay out a roadmap to demonstrate the application of the new methodology. The present analysis shows a simplified version of the methodology of an industrial application on the Core Design and the Multi-Cycle Analysis.

  17. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  18. Impurity pellet injection experiments at TFTR

    International Nuclear Information System (INIS)

    Marmar, E.S.

    1992-01-01

    Impurity (Li and C) pellet injection experiments on TFTR have produced a number of new and significant results. (1) We observe reproducible improvements of TFTR supershots after wall-conditioning by Li pellet injection ('lithiumization'). (2) We have made accurate measurements of the pitch angle profiles of the internal magnetic field using two novel techniques. The first measures the internal field pitch from the polarization angles of Li + line emission from the pellet ablation cloud, while the second measures the pitch angle profiles by observing the tilt of the cigar-shaped Li + emission region of the ablation cloud. (3) Extensive measurements of impurity pellet penetration into plasmas with central temperatures ranging from ∼0.3 to ∼7 keV have been made and compared with available theoretical models. Other aspects of pellet cloud physics have been investigated. (4) Using pellets as a well defined perturbation has allowed study of transport phenomena. In the case of small pellet perturbations, the characteristics of the background plasmas are probed, while with large pellets, pellet induced effects are clearly observed. These main results are discussed in more detail in this paper

  19. Operational experience with the Fermilab 150 GeV injection kicker

    International Nuclear Information System (INIS)

    Trendler, R.C.

    1985-01-01

    The Fermilab E17 injection kicker has been in operation for more than 12000 filament hours and has logged almost 350,000 pulses since commissioning without major failure. The kicker system uses EEV 1193B and 1193C double-ended thyratrons in the MAIN, CLIP and DUMP configuration. In typical operation, the pulser produces 4800 A, 20 μs pulses at a charging voltage of 60kV and is capable of operating at a 80kV charging voltage. Any failure of the injection process can cause the Tevatron cryogenic magnets to quench. This includes any misfires of the injection kicker. Considerable effort was made to maximize reliability and provide interlocks to limit the problems that could happen from injection kicker misfires. The operating experience and reliability of the EEV thyratron will be discussed. Also, the use of the fiber optics, unique charging power supplies, and unusual digital interlocks and the role they play in improved reliability will be discussed

  20. UPTF-TRAM experiments for SBLOCA: Evaluation of condensation processes in TRAM tests A6 and A7

    Energy Technology Data Exchange (ETDEWEB)

    Sonneburg, H.G.; Tuunanen, J.; Palazov, V.V. [Gesellschaft fuer Anlagen-und Reaktorsicherheit (GRS), Muenchen (Germany)

    1995-09-01

    The investigation of thermal-hydraulic phenomena related to reactor transients with accident management measures is the goal of the TRansient and accident Management (TRAM) experimental programme being carried out at the Upper Plenum Test Facility (UPTF) at Mannheim (Germany). These experimental investigations and test analyses are funded by the German Federal Minister for Research and Technology (BMFT). The UPTF simulates these phenomena in a 1:1 such relative to the dimension of a PWR. Condensation of steam during Emergency Core Cooling (ECC) water injection from accumulators into the primary system is one of the phenomena studied within the accumulators into the primary system is one of the phenomena studied within the TRAM programme. This phenomenon partly controls the efficiency of accumulator injection if the high pressure safety systems fail. Beside this, the condensation within the nitrogen inside the accumulator for a certain period controls the pressure development inside the accumulator. Thus, both condensation phenomena determine the ECC flow rate delivered to the primary system. Concerning the condensation inside the primary system, this is also of safety relevance in the case of Pressurized Thermal Shock (PTS) during cold leg injection.

  1. Risk-based assessment of the allowable outage times for the unit 1 leningrad nuclear power plant ECCS components

    International Nuclear Information System (INIS)

    Koukhar, Sergey; Vinnikov, Bronislav

    2009-01-01

    Present paper describes a method for risk - informed assessment of the Allowable Outage Times (AOTs). The AOT is the time, when components of a safety system allowed to be out of service during power operation or during shutdown operation off a plant. If the components are not restored during the time, the plant in operation must be shut down or the plant in a given shutdown mode has to go to safer shutdown mode. Application of the method is also provided for the equipment of the Unit 1 Leningrad NPP ECCS components. For solution of the problem it is necessary to carry out two series of computations using a Living PSA model, level 1. In the first series of the computations the core damage frequency (CDFb) for the base configuration of the plant is determined (there is no equipment out of service). Here the symbol 'b' means the base configuration of a plant. In the second series of the computations the core damage frequency (CDFi) for the configuration of the plant with the component (which is out of service) is calculated. That is here CDFi is determined for the failure probability of the component equal to 1.0 (component 'i' is unavailable). Then it is necessary to determine so called Risk Increase Factor (RIF) using the following ratio: RIFi = CDFi / CDFb. At last the AOT is calculated with the help of the ratio: AOTi = Tppr / RIFi, where Tppr is a period of time between two Planned Preventive Repairs (PPRs). 1. Using the risk based approach the AOTs were calculated for a set of the components of the Unit 1 Leningrad NPP ECCS components. 2. The main conclusion from the analysis is that the current deterministic AOTs for the ECCS components are conservative and should be extended. 3. The risk based extension of the AOTs for the ECCS components can prevent the Unit 1 Leningrad NPP to enter into the operating modes with increased risk. (author)

  2. Data report of ROSA/LSTF experiment SB-HL-12. 1% hot leg break LOCA with SG depressurization and gas inflow

    International Nuclear Information System (INIS)

    Takeda, Takeshi

    2016-01-01

    An experiment SB-HL-12 was conducted on February 24, 1998 using the Large Scale Test Facility (LSTF) in the Rig of Safety Assessment-V (ROSA-V) Program. The ROSA/LSTF experiment SB-HL-12 simulated a 1% hot leg small-break loss-of-coolant accident in a pressurized water reactor under assumptions of total failure of high pressure injection system and non-condensable gas (nitrogen gas) inflow to the primary system from accumulator (ACC) tanks of emergency core cooling system (ECCS). Steam generator (SG) secondary-side depressurization by fully opening the relief valves in both SGs as an accident management (AM) action was initiated immediately after maximum surface temperature of simulated fuel rod reached 600 K. Auxiliary feedwater injection into the secondary-side of both SGs was started immediately after the initiation of AM action. After the onset of AM action due to first core uncovery by core boil-off, the primary pressure decreased following the SG secondary-side pressure, causing core mixture level swell. The fuel rod surface temperature then increased up to 635 K. Second core uncovery by core boil-off took place before loop seal clearing (LSC) induced by steam condensation on ACC coolant injected into cold legs. The core liquid level recovered rapidly after the LSC. The fuel rod surface temperature then increased up to 696 K. The pressure difference became larger between the primary and SG secondary sides after the ACC tanks started to discharge nitrogen gas, which resulted in no actuation of LPI system of ECCS during the experiment. Third core uncovery by core boil-off occurred during the reflux condensation in the SG U-tubes under nitrogen gas inflow. The core power was automatically decreased by the LSTF core protection system when the maximum fuel rod surface temperature exceeded 908 K. The obtained data would be useful to define the conditions for counterpart testing of other integral test facilities to address scaling problems through thermal

  3. Audit of ECCS Availability for CANDU Reactors with an extended O/H interval

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jong Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-10-15

    KINS conducts regulatory periodic inspections of the safety and performance of each nuclear installation during the planned outage every 20 months, pursuant to the Atomic Energy Act. For CANDU reactors, planned outage or overhaul (O/H) have been performed every 15 months. KHNP has been making efforts to extend the O/H intervals of CANDU reactors into 20 months since 2001. Low ECCS availability is one of the regulatory pending issues in the related licensing

  4. Data report for ROSA-IV LSTF 10% hot leg break experiment Run SB-HL-02

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Hirata, Kazuo; Gotou, Hiroki

    1990-03-01

    Experimental data for the 10% hot leg break test, Run SB-HL-02, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on June 30, 1987, are presented. This test assumed total failure of both high pressure injection (HPI) and auxiliary feedwater (AFW) systems. The test results were characterized by asymmetric loop responses, flashing in the cold legs and upper downcomer, as well as condensation depressurization in the cold legs following injection of emergency core coolant (ECC) from accumulators. (author)

  5. Evaluation report on SCTF Core-III test S3-06

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Iguchi, Tadashi; Akimoto, Hajime; Okubo, Tsutomu; Ohnuki, Akira; Adachi, Hiromichi; Murao, Yoshio; Minato, Akihiko; Sakaki, Isao.

    1988-10-01

    In order to investigate the effect of radial power distribution on the thermal-hydraulic characteristics during the reflood phase of a PWR-LOCA with a combined injection type ECCS, a core cooling separate effect test S3-06 and a combined injection test S3-16-Phase 2 were performed using the Slab Core Test Facility (SCTF) Core-III. The radial power distributions in these two tests simulated a reference distribution for a PWR with a combined injection type ECCS and a steep distribution for a PWR with a cold leg injection type ECCS, respectively. Under the radial power distribution of a PWR with a combined injection type ECCS, the radial power distribution had little effect on the thermal-hydraulic behavior in the two-phase up-flow region due to the approximately flat power distribution in this region (power ratio = 1.04 ∼ 1.08). The overall fluid behavior in the pressure vessel was also little affected by the radial power distribution. On the other hand, under the steep radial power distribution (peak power ratio = 1.36), the degree of heat transfer enhancement in high power bundles in the two-phase up-flow region was dominated by the bundlewise radial power ratio as in the case of a PWR with a cold leg injection type ECCS. (author)

  6. Modified ECC ozone sonde for long-duration flights aboard isopicnic drifting balloons

    Science.gov (United States)

    Gheusi, Francois; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clénet, Antoine; Fontaine, Alain; Jambert, Corinne; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore

    2015-04-01

    Since few years, the French space agency CNES has developed boundary-layer pressurized balloons (BLPB) with the capability to transport scientific payloads at isopicnic level over very long distances and durations (up to several weeks in absence of navigation limits). However, the autonomy of conventional electrochemical concentration cell (ECC) ozone sondes, that are widely used for tropospheric and stratospheric soundings, is limited to few hours due to power consumption and electrolyte evaporation (owing to air bubbling in the cathode solution). In collaboration with the French research community, CNES has developed a new ozone payload suited for long duration flights aboard BLPB. The mechanical elements (Teflon pump and motor) and the electrochemical cell of conventional ECC sondes have been kept but the electronic implementation is entirely new. The main feature is the possibility of programming periodic measurement sequences -- with possible remote control during the flight. To increase the ozone sonde autonomy, a strategy has been adopted of short measurement sequences (typically 2-3 min) regularly spaced in time (e.g. every 15 min, which is usually sufficient for air quality studies). The rest of the time, the sonde is at rest (pump motor off). The response time of an ECC sonde to an ozone concentration step is below one minute. Consequently, the measurement sequence is typically composed of a one-minute spin-up period after the pump has been turned on, followed by a one- to two-minute acquisition period. All time intervals can be adjusted before and during the flight. Results of a preliminary ground-based test in spring 2012 are first presented. The sonde provided correct ozone concentrations against a reference UV analyzer every 15 minutes during 4 days. Then we illustrate results from 16 BLBP flights launched in the low troposphere over the Mediterranean during summer field campaings in 2012 and 2013 (TRAQA and ChArMEx programmes). BLPB drifting

  7. Simulation of strain-hardening in ECC uniaxial test specimen by use of a damage mechanics formulation

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  8. In situ water and gas injection experiments performed in the Hades Underground Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Volckaert, G.; Ortiz, L.; Put, M. [SCK-CEN, Mol (Belgium). Geological Waste Disposal Unit

    1995-12-31

    The movement of water and gas through plastic clay is an important subject in the research at SCK-CEN on the possible disposal of high level radioactive waste in the Boom clay layer at Mol. Since the construction of the Hades underground research facility in 1983, SCK-CEN has developed and installed numerous piezometers for the geohydrologic characterization and for in situ radionuclide migration experiments. In situ gas and water injection experiments have been performed at two different locations in the underground laboratory. The first location is a multi filter piezometer installed vertically at the bottom of the shaft in 1986. The second location is a three dimensional configuration of four horizontal multi piezometers installed from the gallery. This piezometer configuration was designed for the MEGAS (Modelling and Experiments on GAS migration through argillaceous rocks) project and installed in 1992. It contains 29 filters at distances between 10 m and 15 m from the gallery in the clay. Gas injection experiments show that gas breakthrough occurs at a gas overpressure of about 0.6 MPa. The breakthrough occurs by the creation of gas pathways along the direction of lowest resistance i.e. the zone of low effective stress resulting from the drilling of the borehole. The water injections performed in a filter -- not used for gas injection -- show that the flow of water is also influenced by the mechanical stress conditions. Low effective stress leads to higher hydraulic conductivity. However, water overpressures up to 1.3 MPa did not cause hydrofracturing. Water injections performed in a filter previously used for gas injections, show that the occluded gas hinders the water flow and reduces the hydraulic conductivity by a factor two.

  9. Registration of ELF waves in rocket-satellite experiment with plasma injection

    Science.gov (United States)

    Korobeinikov, V. G.; Oraevskii, V. N.; Ruzhin, Iu. Ia.; Sobolev, Ia. P.; Skomarovskii, V. S.; Chmyrev, V. M.; Namazov, C. A.; Pokhunkov, A. A.; Nesmeianov, V. I.

    1992-12-01

    Two rocket KOMBI-SAMA experiments with plasma injection at height 100-240 km were performed in August 1987 in the region of Brazilian magnetic anomaly (L = 1.25). The launching time of the rocket was determined so that plasma injection was at the time when COSMOS 1809 satellite passed as close as possible to magnetic tube of injection. Caesium plasma jet was produced during not less than 300 s by an electric plasma generator separated from the payload. When the satellite passed the geomagnetic tube intersecting the injection region an enhancement of ELF emission at 140 Hz, 450 Hz by a factor of 2 was registered on board the satellite. An enhancement of energetic particle flux by a factor of 4-5 was registered on board the rocket. Observed ELF emission below 100 Hz is interpreted as the generation of oblique electromagnetic ion-cyclotron waves due to drift plasma instability at the front of the plasma jet.

  10. Status of experimental verification of ECCS efficiency

    International Nuclear Information System (INIS)

    Hein, D.; Watzinger, H.

    1978-01-01

    For the emergency cooling system of KWU pressurized water reactors with combined hot and cold leg injection an outline is given of the status of experiments designed to prove the efficiency of the emergency cooling system. This proof has been established by basic investigations which clarify the physical processes, by ''separate effects tests'' to derive and check correlations, and finally by investigations on the PKL test facility, in which a 1300 MWe pressurized water reactor including the primary circuts is simulated. These ''system effects tests'' are used to verify computer codes which are ultimately used to make predictions for the reactor. (author)

  11. Wall conditioning experiments on TFTR using impurity pellet injection

    International Nuclear Information System (INIS)

    Strachan, J.D.; Mansfield, D.K.; Bell, M.G.; Collins, J.; Ernst, D.; Hill, K.; Hosea, J.; Timberlake, J.; Ulrickson, M.; Terry, J.; Marmar, E.; Snipes, J.

    1994-01-01

    This work describes experiments intended to optimize the limiter conditioning for TFTR supershots. It is shown that deposition of thin layers of lithium on the limiters by impurity pellet injection changes the plasma-wall interaction and improves supershot performance. Series of up to ten Ohmic plasmas each with two lithium pellets were useful in pre-conditioning the limiter. Generally, plasma performance increased with the amount of lithium deposited up to the maximal amount which could be deposited. Experiments were performed with different materials being deposited (carbon, boron and lithium) and with different methods of deposition. ((orig.))

  12. Exxon Nuclear Company ECCS evaluation of a 2-loop Westinghouse PWR with dry containment using the ENC WREM-II ECCS model. Large break example problem

    International Nuclear Information System (INIS)

    Krajicek, J.E.

    1977-01-01

    This document is presented as a demonstration of the ENC WREM-II ECCS model calculational procedure applied to a Westinghouse 2-loop PWR with a dry containment (R. E. Ginna plant, for example). The hypothesized Loss-of-Coolant Accident (LOCA) investigated was a split break with an area equal to twice the pipe cross-sectional area. The break was assumed to occur in one pump discharge pipe (DECLS break). The analyses involved calculations using the ENC WREM-II model. The following codes were used: RELAP4-EM/ENC26A for blowdown and hot channel analyses, RELAP4-EM FLOOD/ENC26A for core reflood analysis, CONTEMPT LT/22 modified for containment backpressure analysis, and TOODEE2/APR77 for heatup analysis

  13. Incorporating Indigenous Knowledge and Practice into ECCE: A Comparison of Programs in The Gambia, Senegal and Mali

    Science.gov (United States)

    Soudee, Alicia Ranck

    2009-01-01

    Early Childhood Development (ECD) has emerged as a theme in international and African dialogue on education in recent years. UNESCO's Division of Basic Education Early Childhood promotes an integrated approach to Early Childhood Care and Education (ECCE) policy development and review. The study examines how this is implemented in three West…

  14. Pellet injection experiments on the TFR Tokamak

    International Nuclear Information System (INIS)

    1987-02-01

    Single pellet injection experiments have been carried out on TFR with the aim to improve the experimental knowledge of ablation physical processes and also to get a better description of the heat and matter transport during and after pellet evaporation. Ablation clouds have been photographed, providing experimental penetration depths in rough agreement with the neutral shielding model. Observation of striations in the cloud has led to an experimental determination of the safety factor profile. Parameters of the plasma in the ablation cloud have been spectroscopically determined. Fast heat transport has been evidenced during pellet evaporation (∼ 100 μs) which exhibits some features of minor or major disruptions (appearance of a m = 1, n = 1 island on the q = 1 surface, bursts of density fluctuations, comparable heat diffusivity, ...). Matter transport takes place on a larger time scale (∼ 10 ms). This long temporal relaxation is well accounted for by the 1D-MAKOKOT computer code without changing the transport coefficients after pellet injection. Heat and matter transport are affected by the presence of the m = 1, n = 1 island on the q = 1 surface

  15. Microfluidic model experiments on the injectability of monoclonal antibody solutions

    Science.gov (United States)

    Duchene, Charles; Filipe, Vasco; Nakach, Mostafa; Huille, Sylvain; Lindner, Anke

    2017-11-01

    Autoinjection devices that allow patients to self-administer medicine are becoming used more frequently; however, this advance comes with an increased need for precision in the injection process. The rare occurrence of protein aggregates in solutions of monoclonal antibodies constitutes a threat to the reliability of such devices. Here we study the flow of protein solutions containing aggregates in microfluidic model systems, mimicking injection devices, to gain fundamental understanding of the catastrophic clogging of constrictions of given size. We form aggregates by mechanically shaking or heating antibody solutions and then inject these solutions into microfluidic channels with varying types of constrictions. Geometrical clogging occurs when aggregates reach the size of the constriction and can in some cases be undone by increasing the applied pressure. We perform systematic experiments varying the relative aggregate size and the flow rate or applied pressure. The mechanical deformation of aggregates during their passage through constrictions is investigated to gain a better understanding of the clogging and unclogging mechanisms.

  16. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    International Nuclear Information System (INIS)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S.

    2015-01-01

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  17. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S., E-mail: yhwang@snu.ac.kr

    2015-10-15

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  18. Fate of herbicides in a shallow aerobic aquifer: A continuous field injection experiment (Vejen,Denmark)

    DEFF Research Database (Denmark)

    Broholm, Mette; Rügge, K.; Tuxen, Nina

    2001-01-01

    A continuous, natural gradient, field injection experiment, involving six herbicides and a tracer, was performed in a shallow aerobic aquifer near Vejen, Denmark. Bentazone, ()-2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP), dichlorprop, isoproturon, and the dichlobenil metabolite 2,6-dichlor...... in groundwater potentials. An average flow velocity of 0.5 m/d was observed, as depicted by bromide. Bentazone, BAM, MCPP, and dichlorprop retardation was negligible, and only slight retardation of isoproturon was observed in the continuous injection experiment and a preceding pulse experiment. No degradation...... of bentazone was observed in the aerobic aquifer during the monitoring period. BAM and isoproturon were not degraded within 5 m downgradient of the injection. The two phenoxy acids MCPP and dichlorprop were both degraded in the aerobic aquifer. Near the source a lag phase was observed followed by fast...

  19. BWR fuel experience with zinc injection

    International Nuclear Information System (INIS)

    Levin, H.A.; Garcia, S.E.

    1995-01-01

    In 1982 a correlation between low primary recirculation system dose rates in BWR's and the presence of ionic zinc in reactor water was identified. The source of the zinc was primarily from Admiralty brass condensers. Plants with brass condensers are called ''natural zinc'' plants. Brass condensers were also a source of copper that was implicated in crude induced localized corrosion (CILC) fuel failures. In 1986 the first BWR intentionally injected zinc for the benefits of dose rate control. Although zinc alone was never implicated in fuel degradation of failures, a comprehensive fuel surveillance program was initiated to monitor fuel performance. Currently there are 14 plants that are injecting zinc. Six of these plants are also on hydrogen water chemistry. This paper describes the effect on both Zircaloy corrosion and the cruding characteristics as a result of these changes in water chemistry. Fuel rod corrosion was found to be independent of the specific water chemistry of the plants. The corrosion behavior was the same with the additions of zinc alone or zinc plus hydrogen and well within the operating experience for fuel without either of these additions. No change was observed in the amounts of crude deposited on the fuel rods, both for the adherent and loosely held deposits. One of the effects of the zinc addition was the trend to form more of the zinc rich iron spinel in the fuel deposits rather than the hematite deposits that are predominantly formed with non additive water chemistry

  20. Feeding practice among 6-36 months old in Tanzania and Uganda: reliability and relationship with early childhood caries, ECC.

    Science.gov (United States)

    Masumo, Ray; Bardsen, Asgeir; Mashoto, Kijakazi; Åstrøm, Anne Nordrehaug

    2013-09-01

    To assess the reproducibility of caregivers' responses to dietary recall from birth and 24-h dietary recall with respect to infants' intake of sugared snacks and to assess whether those assessment methods provide comparable results for groups of infants. Re-test reliability and clinical covariates of time to first exposure of sugared snacks and time to termination of breastfeeding were also examined. It was hypothesized that time to first exposure/termination would vary according to socio-demographic profile and ECC. Interviews and clinical oral examinations were carried out in Kampala and Manyara, including 1221 and 816 child-caregiver pairs. Reproducibility was assessed using Cohen's kappa and Intra Class Correlation Coefficient, ICC. Adjusted Cox regression was used to model time to first exposure of sugared snacks and time to termination of breastfeeding. Cohen's kappa for intake of sugar items ranged from 0.40-1.0, with no differences observed between average intakes at test-re-test. Mean sugar score based on 24-h recall increased significantly by increasing quartiles of the sugar score based on recall from birth. Cox regression revealed that the odds ratio, OR, for early exposure to various sugared snacks and the ORs for early termination of breastfeeding were significantly smaller in infants with than without ECC. Fair-to-good reproducibility was established. Infant's sugar consumption emerge as early as 6 months of age. Survival of any breastfeeding and non-exposure to sugared snacks was most prolonged among infants with ECC. This has implications for interventions needed to improve feeding habits of infants and toddlers.

  1. Nietzsche como destino da filosofia e da humanidade? interpretação contextual do § 1 do capítulo "por que sou um destino", de ecce homo

    Directory of Open Access Journals (Sweden)

    Werner Stegmaier

    2010-01-01

    Full Text Available The following translation is a reduced and revised version of the paper Schicksal Nietzsche? Zu Nietzsches Selbsteinschätzung als Schicksal der Philosophie und der Menschheit (Ecce Homo, Warum ich ein Schicksal bin §1" - originally published in Nietzsche-Studien 37 (2008 - which was specially prepared to be presented in lecture organized by the Grupo de Pesquisa Spinoza & Nietzsche (Spinoza & Nietzsche research group - SpiN, in the Universidade Federal do Rio de Janeiro (Rio de Janeiro's Federal University, on September 14, 2009. In the text, the autor employs his own philological-hermeneutical methodology, which is called contextual interpretation, in the purpose to clarify the concepts of the first aphorism from "Why I am a destiny", from Ecce Homo, in its own context, in the context of Ecce Homo and in the context of the entire work from Nietzsche.

  2. Seismic and aseismic fault slip in response to fluid injection observed during field experiments at meter scale

    Science.gov (United States)

    Cappa, F.; Guglielmi, Y.; De Barros, L.; Wynants-Morel, N.; Duboeuf, L.

    2017-12-01

    During fluid injection, the observations of an enlarging cloud of seismicity are generally explained by a direct response to the pore pressure diffusion in a permeable fractured rock. However, fluid injection can also induce large aseismic deformations which provide an alternative mechanism for triggering and driving seismicity. Despite the importance of these two mechanisms during fluid injection, there are few studies on the effects of fluid pressure on the partitioning between seismic and aseismic motions under controlled field experiments. Here, we describe in-situ meter-scale experiments measuring synchronously the fluid pressure, the fault motions and the seismicity directly in a fault zone stimulated by controlled fluid injection at 280 m depth in carbonate rocks. The experiments were conducted in a gallery of an underground laboratory in south of France (LSBB, http://lsbb.eu). Thanks to the proximal monitoring at high-frequency, our data show that the fluid overpressure mainly induces a dilatant aseismic slip (several tens of microns up to a millimeter) at the injection. A sparse seismicity (-4 laws, we simulated an experiment and investigated the relative contribution of the fluid pressure diffusion and stress transfer on the seismic and aseismic fault behavior. The model reproduces the hydromechanical data measured at injection, and show that the aseismic slip induced by fluid injection propagates outside the pressurized zone where accumulated shear stress develops, and potentially triggers seismicity. Our models also show that the permeability enhancement and friction evolution are essential to explain the fault slip behavior. Our experimental results are consistent with large-scale observations of fault motions at geothermal sites (Wei et al., 2015; Cornet, 2016), and suggest that controlled field experiments at meter-scale are important for better assessing the role of fluid pressure in natural and human-induced earthquakes.

  3. FIX-II/2032, BWR Pump Trip Experiment 2032, Simulation Mass Flow and Power Transients

    International Nuclear Information System (INIS)

    1988-01-01

    1 - Description of test facility: In the FIX-II pump trip experiments, mass flow and power transients were simulated subsequent to a total loss of power to the recirculation pumps in an internal pump boiling water reactor. The aim was to determine the initial power limit to give dryout in the fuel bundle for the specified transient. In addition, the peak cladding temperature was measured and the rewetting was studied. 2 - Description of test: Pump trip experiment 2032 was a part of test group 2, i.e. the mass flow transient was to simulate the pump coast down with a pump inertia of 11.3 kg.m -2 . The initial power in the 36-rod bundle was 4.44 MW which gave dryout after 1.4 s from the start of the flow transient. A maximum rod cladding temperature of 457 degrees C was measured. Rewetting was obtained after 7.6 s. 3 - Experimental limitations or shortcomings: No ECCS injection systems

  4. Reflooding and boil-off experiments in a VVER-440 like rod bundle and analyses with the CATHARE code

    International Nuclear Information System (INIS)

    Korteniemi, V.; Haapalehto, T.; Puustinen, M.

    1995-01-01

    Several experiments were performed with the VEERA facility to simulate reflooding and boil-off phenomena in a VVER-440 like rod bundle. The objective of these experiments was to get experience of a full-scale bundle behavior and to create a database for verification of VVER type core models used with modern thermal-hydraulic codes. The VEERA facility used in the experiments is a scaled-down model of the Russian VVER-440 type pressurized water reactors used in Loviisa, Finland. The test section of the facility consists of one full-scale copy of a VVER-440 reactor rod bundle with 126 full-length electrically heated rod simulators. Bottom and top-down reflooding, different modes of emergency core cooling (ECC) injection and the effect of heating power on the heat-up of the rods was studied. In this paper the results of calculations simulating two reflood and one boil-off experiment with the French CATHARE2 thermal-hydraulic code are also presented. Especially the performance of the recently implemented top-down reflood model of the code was studied

  5. Reflooding and boil-off experiments in a VVER-440 like rod bundle and analyses with the CATHARE code

    Energy Technology Data Exchange (ETDEWEB)

    Korteniemi, V.; Haapalehto, T. [Lappeenranta Univ. of Technology (Finland); Puustinen, M. [VTT Energy, Lappeenranta (Finland)

    1995-09-01

    Several experiments were performed with the VEERA facility to simulate reflooding and boil-off phenomena in a VVER-440 like rod bundle. The objective of these experiments was to get experience of a full-scale bundle behavior and to create a database for verification of VVER type core models used with modern thermal-hydraulic codes. The VEERA facility used in the experiments is a scaled-down model of the Russian VVER-440 type pressurized water reactors used in Loviisa, Finland. The test section of the facility consists of one full-scale copy of a VVER-440 reactor rod bundle with 126 full-length electrically heated rod simulators. Bottom and top-down reflooding, different modes of emergency core cooling (ECC) injection and the effect of heating power on the heat-up of the rods was studied. In this paper the results of calculations simulating two reflood and one boil-off experiment with the French CATHARE2 thermal-hydraulic code are also presented. Especially the performance of the recently implemented top-down reflood model of the code was studied.

  6. Evaluation of patients’ experiences at different stages of the intravitreal injection procedure – what can be improved?

    Directory of Open Access Journals (Sweden)

    Tailor R

    2011-10-01

    Full Text Available Rajen Tailor, Rebecca Beasley, Yit Yang, Niro NarendranWolverhampton and Midland Counties Eye Infirmary, New Cross Hospital, Wolverhampton, UKIntroduction: Intravitreal injection of ranibizumab has become one of the most commonly performed ophthalmic procedures. It is timely to conduct an evaluation of the injection procedure from the patient’s perspective so as to determine ways to improve patient experience. The purpose of this study was to quantitatively describe patients’ experiences of the different stages of the intravitreal injection procedure and provide suggestions for improvement.Method: Following intravitreal injection, patients were administered a questionnaire to score the distress felt for each of ten parts of the whole injection process from the initial waiting to the final instillation of topical antibiotic at the end. A score of higher than 4 was regarded as significantly unpleasant. The proportion of scores above 4 for each step was used to evaluate the relative distress experienced by patients for the different parts of the procedure.Results: A total of 42 patients were surveyed. The step with the highest percentage of patients scoring more than 4 was the injection step (19%. However, cumulatively, the steps relating to the application of the drape, the speculum, and the removal of drape accounted for 53% of scores greater than 4.Conclusion: There is considerable variation in how patients tolerate different stages of the injection procedure. The needle entry was the most unpleasant step followed by the draping steps cumulatively. Use of subconjunctival anesthesia, a perforated drape, and alternative lid exclusion devices may help to improve the patient’s tolerability of the procedure and experience.Keywords: ranibizumab, patient experience, age-related macular degeneration

  7. Transient computational fluid dynamics analysis of emergency core cooling injection at natural circulation conditions

    International Nuclear Information System (INIS)

    Scheuerer, Martina; Weis, Johannes

    2012-01-01

    Highlights: ► Pressurized thermal shocks are important phenomena for plant life extension and aging. ► The thermal-hydraulics of PTS have been studied experimentally and numerically. ► In the Large Scale Test Facility a loss of coolant accident was investigated. ► CFD software is validated to simulate the buoyancy driven flow after ECC injection. - Abstract: Within the framework of the European Nuclear Reactor Integrated Simulation Project (NURISP), computational fluid dynamics (CFD) software is validated for the simulation of the thermo-hydraulics of pressurized thermal shocks. A proposed validation experiment is the test series performed within the OECD ROSA V project in the Large Scale Test Facility (LSTF). The LSTF is a 1:48 volume-scaled model of a four-loop Westinghouse pressurized water reactor (PWR). ROSA V Test 1-1 investigates temperature stratification under natural circulation conditions. This paper describes calculations which were performed with the ANSYS CFD software for emergency core cooling injection into one loop at single-phase flow conditions. Following the OECD/NEA CFD Best Practice Guidelines (Mahaffy, 2007) the influence of grid resolution, discretisation schemes, and turbulence models (shear stress transport and Reynolds stress model) on the mixing in the cold leg were investigated. A half-model was used for these simulations. The transient calculations were started from a steady-state solution at natural circulation conditions. The final calculations were obtained in a complete model of the downcomer. The results are in good agreement with data.

  8. High-beta experiments with neutral-beam injection on PDX

    International Nuclear Information System (INIS)

    Johnson, D.; Bell, M.; Bitter, M.

    1983-01-01

    Experimental investigations of high-beta plasmas produced in PDX with near-perpendicular neutral-beam injection are reported. Systematic power scans have been performed over a wide range of toroidal fields (νsub(T)q.7 T< Bsub(T)<2.2 T) and plasma currents (200 kA< Isub(p)<500 kA). At high toroidal fields, the change in total stored energy due to beam injection increases linearly with input power and also increases with plasma current. At lower toroidal fields and low injection power levels, the stored energy also increases with power and plasma current. However, at high power and low toroidal fields, a saturation in heating is observed. This result suggests the onset of a νsub(T) limit for circular cross-section tokamaks with near-perpendicular injection. Scaling experiments indicate that this νsub(T) limit increases with rising 1/q. Values of νsub(T)approx.=3% at qsub(PSI)=1.8 have been achieved. At high values of νsub(T)q, short bursts of MHD activity are observed, synchronized with sharply increased fluxes of perpendicular charge-exchange neutrals and rapid decreases in the rate of beam-driven neutron production. When strong bursts occur, there is a significant depletion of the fast-ion population. Estimates of the fast-ion loss indicate that it could explain the observed decrease in heating, although an additional reduction in thermal-plasma confinement cannot be ruled out. Numerical studies using measured pressure profiles predict that the equilibria obtained become unstable to the ideal n=1 internal mode, at about the same value of 0 where the new fluctuations are observed. (author)

  9. Effect of capillary number on the oil recovery using oil-water emulsion injection in core flooding experiments

    Energy Technology Data Exchange (ETDEWEB)

    Guillen Nunez, Victor Raul; Carvalho, Marcio da Silveira [Pontifical Catholic University of Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. of Mechanical Engineering], E-mail: msn@puc-rio.br; Basante, Vladimir Alvarado [University of Wyoming, Laramie, WY (United States). Dept. of Chemical/Petroleum Engineering], E-mail: valvard@uwyo.edu

    2010-07-01

    The Water injection flooding is a common method to improve reservoir sweep and pressure maintenance. The heavy-oil-recovery efficiency is in part limited by the high water-to-oil mobility ratio. Several enhanced oil recovery methods are being developed as more efficient alternatives to water flooding. Dispersion injection, in particular oil-water emulsion injection, has been tried with relative success as an enhanced oil recovery method, but the technique is not fully developed or understood. If emulsion injection proves to be an effective EOR method, its use would bring the added benefit of disposing produced water with small oil content that could be modified to serve as the injected oil-water emulsion. The use of such methods requires a detailed analysis of the different flow regimes of emulsions through the porous space of a reservoir rock. If the drop size of the disperse phase is of the same order of magnitude as the pore size, the drops may agglomerate and partially block water flow through pores. This flow regime may be used to control the mobility of the injected liquid, leading to higher recovery factor. We have shown in recent experiments of oil displacement in a sandstone core that, the oil recovery factor could be raised from approximately 40 %, obtained with water injection only, up to approximately 75 % by alternating water and emulsion injection. Although these results clearly show the improvement in the recovery factor, the mechanisms responsible for the phenomenon have not been clearly elucidated. In this work, two sandstone cores were used to demonstrate the effect of flow rate (capillary number) on the mobility control by emulsion injection. Figure 1 shows a schematic representation of the experiment set-up. The experiments show that raising the flow rate by a factor of 10 (0.03 ml/min to 0.3 ml/min), the oil recovered factor decreases considerably. (author)

  10. Neutral Beam Injection Requirements and Design Issues for the National Compact Stellarator Experiment

    International Nuclear Information System (INIS)

    Kugel, H.W.; Neilson, H.; Reiersen, W.; Zarnstorff, M.

    2002-01-01

    The National Compact Stellarator Experiment (NCSX) will require 6 MW of 50 keV neutral beam injection (NBI) with initial pulse lengths of 500 msec and upgradeable to pulse lengths of 1.5 sec. This paper discusses the NCSX NBI requirements and design issues, and shows how these are provided by the candidate PBX-M [Princeton Beta Experiment-Modification] NBI system

  11. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1976-09-01

    Thermo-hydraulic behavior in the primary cooling system of a pressurized water reactor with an upper head injection system (UHI) in a postulated loss-of-coolant accident (LOCA) has been studied with ROSA-II test facility. Simulated UHI and internal structures of the pressure vessel were installed to the facility for the experiment. Nine maximum-sized double-ended break tests and one medium-sized split break test were performed for the cold-leg break condition. The results are as follows: (1) Fluid mixing in the upper head is not perfect. (2) Cold water injection into the steam or two-phase fluid causes violent depressurization due to the condensation. Flow pattern in the primary cooling system is largely influenced by the above two. (auth.)

  12. Assessment of wall friction model in multi-dimensional component of MARS with air–water cross flow experiment

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jin-Hwa [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Choi, Chi-Jin [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Cho, Hyoung-Kyu, E-mail: chohk@snu.ac.kr [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Park, Goon-Cherl [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of)

    2017-02-15

    Recently, high precision and high accuracy analysis on multi-dimensional thermal hydraulic phenomena in a nuclear power plant has been considered as state-of-the-art issues. System analysis code, MARS, also adopted a multi-dimensional module to simulate them more accurately. Even though it was applied to represent the multi-dimensional phenomena, but implemented models and correlations in that are one-dimensional empirical ones based on one-dimensional pipe experimental results. Prior to the application of the multi-dimensional simulation tools, however, the constitutive models for a two-phase flow need to be carefully validated, such as the wall friction model. Especially, in a Direct Vessel Injection (DVI) system, the injected emergency core coolant (ECC) on the upper part of the downcomer interacts with the lateral steam flow during the reflood phase in the Large-Break Loss-Of-Coolant-Accident (LBLOCA). The interaction between the falling film and lateral steam flow induces a multi-dimensional two-phase flow. The prediction of ECC flow behavior plays a key role in determining the amount of coolant that can be used as core cooling. Therefore, the wall friction model which is implemented to simulate the multi-dimensional phenomena should be assessed by multidimensional experimental results. In this paper, the air–water cross film flow experiments simulating the multi-dimensional phenomenon in upper part of downcomer as a conceptual problem will be introduced. The two-dimensional local liquid film velocity and thickness data were used as benchmark data for code assessment. And then the previous wall friction model of the MARS-MultiD in the annular flow regime was modified. As a result, the modified MARS-MultiD produced improved calculation result than previous one.

  13. Performance Verification for Safety Injection Tank with Fluidic Device

    International Nuclear Information System (INIS)

    Yune, Seok Jeong; Kim, Da Yong

    2014-01-01

    In LBLOCA, the SITs of a conventional nuclear power plant deliver excessive cooling water to the reactor vessel causing the water to flow into the containment atmosphere. In an effort to make it more efficient, Fluidic Device (FD) is installed inside a SIT of Advanced Power Reactor 1400 (APR 1400). FD, a complete passive controller which doesn't require actuating power, controls injection flow rates which are susceptible to a change in the flow resistance inside a vortex chamber of FD. When SIT Emergency Core Cooling (ECC) water level is above the top of the stand pipe, the water enters the vortex chamber through both the top of the stand pipe and the control ports resulting in injection of the water at a large flow rate. When the water level drops below the top of the stand pipe, the water only enters the vortex chamber through the control ports resulting in vortex formation in the vortex chamber and a relatively small flow injection. Performance verification of SIT shall be carried out because SITs play an integral role to mitigate accidents. In this paper, the performance verification method of SIT with FD is presented. In this paper, the equations for calculation of flow resistance coefficient (K) are induced to evaluate on-site performance of APR 1400 SIT with FD. Then, the equations are applied to the performance verification of SIT with FD and good results are obtained

  14. Parametric Effects of Debris Source, Environments, and Design Options on the Overall Performance of ECCS Recirculation Sump

    International Nuclear Information System (INIS)

    Park, Jong Woon; Kim, Chang Hyun

    2006-01-01

    A primary safety issue regarding long-term recirculation core cooling following a LOCA (Loss of Coolant Accident) is that LOCA-generated debris may be transported to the recirculation sump screen, resulting in adverse blockage on the sump screen and deterioration of available NPSH (Net Positive Suction Head) of ECCS (Emergency Core Cooling System). USNRC identified this as Generic Safety Issue (GSI) 191 and issued the Generic Letter 04-02 to resolve the issue. The GL required that all PWR owners perform an engineering assessment of their containment recirculation sumps to ensure they will not suffer from excessive blockage. The guidance report (GR) for PWR sump performance evaluation has been developed by NEI (Nuclear Energy Institute) and approved by the USNRC. In Korea, Korea Hydro and Nuclear Power Company (KHNP) is performing the assessment of Kori unit 1 and planning for remaining plants in the near future. The objective of the assessment is to derive required plant modifications including insulation, sump screen, etc. To derive the cost-effective modification items, we have to get insight on the parametric effects of plant conditions and design. Therefore, the general effects of debris source, containment environments and debris interceptor on the performance of ECCS recirculation sump with respect to head loss are parametrically investigated

  15. Fat injection to correct contour deformities of the reconstructed breast: a single surgeon experience

    Directory of Open Access Journals (Sweden)

    Youssef Tahiri

    2015-06-01

    Full Text Available Aim: Autologous fat grafting has gained acceptance as a technique to improve aesthetic outcomes in breast reconstruction. The purpose of this study was to share our clinical experience using autologous fat injection to correct contour deformities during breast reconstruction. Methods: A single surgeon, prospectively maintained database of patients who underwent autologous fat injection during breast reconstruction from January 2008 to November 2013 at McGill University Health Center was reviewed. Patient characteristics, breast history, type of breast reconstruction, volume of fat injected, and complications were analyzed. Results: One hundred and twenty-four patients benefited from autologous fat injection from January 2008 to November 2013, for a total of 187 treated breasts. The patients were on average 49.3 years old (΁ 8.9 years. Fat was harvested from the medial thighs (20.5%, flanks (39.1%, medial thighs and flanks (2.9%, trochanters (13.3%, medial knees (2.7%, and abdomen (21.9%. An average of 49.25 mL of fat was injected into each reconstructed breast. A total of 187 breasts in 124 patients were lipo-infiltrated during the second stage of breast reconstruction. Thirteen breasts (in 12 separate patients were injected several years after having undergone lumpectomy and radiotherapy. Of the 187 treated breasts, 118 were reconstructed with expanders to implants, 45 with deep inferior epigastric perforator flaps, 9 with latissimus dorsi flaps with implants, 4 with transverse rectus abdominis myocutaneous flaps, and 13 had previously undergone lumpectomy and radiotherapy. Six complications were noted in the entire series, for a rate of 3.2%. All were in previously radiated breasts. Average follow-up time was 12 months (range: 2-36 months. Conclusion: Fat injection continues to grow in popularity as an adjunct to breast reconstruction. Our experience demonstrates a low complication rate as compared to most surgical interventions of the breast

  16. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  17. Transient computational fluid dynamics analysis of emergency core cooling injection at natural circulation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Scheuerer, Martina, E-mail: Martina.Scheuerer@grs.de [Gesellschaft fuer Anlagen- und Reaktorsicherheit, Forschungsinstitute, 85748 Garching (Germany); Weis, Johannes, E-mail: Johannes.Weis@grs.de [Gesellschaft fuer Anlagen- und Reaktorsicherheit, Forschungsinstitute, 85748 Garching (Germany)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Pressurized thermal shocks are important phenomena for plant life extension and aging. Black-Right-Pointing-Pointer The thermal-hydraulics of PTS have been studied experimentally and numerically. Black-Right-Pointing-Pointer In the Large Scale Test Facility a loss of coolant accident was investigated. Black-Right-Pointing-Pointer CFD software is validated to simulate the buoyancy driven flow after ECC injection. - Abstract: Within the framework of the European Nuclear Reactor Integrated Simulation Project (NURISP), computational fluid dynamics (CFD) software is validated for the simulation of the thermo-hydraulics of pressurized thermal shocks. A proposed validation experiment is the test series performed within the OECD ROSA V project in the Large Scale Test Facility (LSTF). The LSTF is a 1:48 volume-scaled model of a four-loop Westinghouse pressurized water reactor (PWR). ROSA V Test 1-1 investigates temperature stratification under natural circulation conditions. This paper describes calculations which were performed with the ANSYS CFD software for emergency core cooling injection into one loop at single-phase flow conditions. Following the OECD/NEA CFD Best Practice Guidelines (Mahaffy, 2007) the influence of grid resolution, discretisation schemes, and turbulence models (shear stress transport and Reynolds stress model) on the mixing in the cold leg were investigated. A half-model was used for these simulations. The transient calculations were started from a steady-state solution at natural circulation conditions. The final calculations were obtained in a complete model of the downcomer. The results are in good agreement with data.

  18. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  19. Evaluation report on SCTF Core-III Test S3-22

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Iwamura, Takamichi; Akimoto, Hajime; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio; Adachi, Hiromichi.

    1991-07-01

    Two tests (Tests S3-20 and S3-22) were conducted with JAERI's Slab Core Test Facility (SCTF) Core-III in order to investigate water break-through and core cooling behaviors under the intermittent ECC water delivery from the hot legs to one location in the upper plenum and the alternate ECC water delivery to two locations in the upper plenum during reflooding, respectively. This report presents an analysis on Test S3-22 (the alternate case). Subcooled ECC water was injected alternately just above the upper core support plate above Bundles 7 and 8 and Bundles 3 and 4. The total injection rate from both injection ports was the same as that in SCTF Test S3-20 and Test S3-13. Analyzing the test data together with those of Tests S3-13 and S3-20 the following has been found: (1) Alternate break-through occurred immediately corresponding to the alternate ECC water injection except for one period, during which no break-through was observed. However, there observed a difference in break-through behavior that break-through was strong above the low power region, whereas weak above the high power region. (2) Although its break-through behavior was different, nearly the same core cooling as in the continuous or intermittent ECC water delivery case was observed except for the period around quench. (3) Around quench time, degraded core cooling comparing to the continuous or intermittent ECC water delivery case was observed. That is, quench time at the midplane level of the present test was 35 s later than in the continuous case. This is considered to result from decrease in core water inventory caused by water sealing at the cross-over leg. (J.P.N.)

  20. A study on the effect of fluidic device installed in a safety injection tank on thermal-hydraulic phenomena of large break loss of coolant accident

    International Nuclear Information System (INIS)

    Chung, Young Jong; Bae, Kyoo Hwan; Song, Jin Ho; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The performance of the Safety Injection Tank (SIT) with fluidic device (advanced SIT) is analyzed for the large break loss of coolant accident (LBLOCA) using RELAP5/MOD3.1-KREM. First the case is analyzed using the conventional SIT. Among various cases the case with 4-split downcomer, discharge coefficient Cd=0.6, MCP trip with reactor trip and break location of cold leg discharge side with the pressurizer is found to be the most limiting case. For the same condition, the advanced SIT results the similar PCT, however it can maintain adequately the liquid level in the downcomer. By changing the ECCS location from the current injection to the cold leg elevations, PCT is improved by 75 K. (Author). 6 refs., 4 tabs., 54 figs

  1. Data report for ROSA-IV LSTF gravity-driven safety injection experiment run SB-CL-27

    International Nuclear Information System (INIS)

    Yonomoto, Taisuke; Saitou, Seishi; Kuroda, Takeshi

    1994-03-01

    Experimental data are presented for the passive injection test, Run SB-CL-27, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on September 17, 1992. This experiment simulated thermal-hydraulic behavior of a gravity-driven, passive safety injection system during a small-break loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). The injection system consisted of a gravity-driven injection tank, located above the reactor vessel, with connecting lines. The tank was initially filled with water of room temperature at the same pressure as the pressurizer. The connecting lines to the cold leg and to the vessel downcomer were opened at the test initiation. Then, a natural circulation flow developed in the loop which was formed by these lines and the injection tank. The hot water in the cold leg circulated into the upper part of tank and accumulated there causing a significant thermal stratification. This thermal stratification prevented direct-contact condensation of steam from occurring during the subsequent tank drain-down phase. Therefore, no condensation-induced depressurization of the tank, affecting adversely the injection performance, occurred. (author)

  2. The experience of initiating injection drug use and its social context: a qualitative systematic review and thematic synthesis.

    Science.gov (United States)

    Guise, Andy; Horyniak, Danielle; Melo, Jason; McNeil, Ryan; Werb, Dan

    2017-12-01

    Understanding the experience of initiating injection drug use and its social contexts is crucial to inform efforts to prevent transitions into this mode of drug consumption and support harm reduction. We reviewed and synthesized existing qualitative scientific literature systematically to identify the socio-structural contexts for, and experiences of, the initiation of injection drug use. We searched six databases (Medline, Embase, PsychINFO, CINAHL, IBSS and SSCI) systematically, along with a manual search, including key journals and subject experts. Peer-reviewed studies were included if they qualitatively explored experiences of or socio-structural contexts for injection drug use initiation. A thematic synthesis approach was used to identify descriptive and analytical themes throughout studies. From 1731 initial results, 41 studies reporting data from 1996 participants were included. We developed eight descriptive themes and two analytical (higher-order) themes. The first analytical theme focused on injecting initiation resulting from a social process enabled and constrained by socio-structural factors: social networks and individual interactions, socialization into drug-using identities and choices enabled and constrained by social context all combine to produce processes of injection initiation. The second analytical theme addressed pathways that explore varying meanings attached to injection initiation and how they link to social context: seeking pleasure, responses to increasing tolerance to drugs, securing belonging and identity and coping with pain and trauma. Qualitative research shows that injection drug use initiation has varying and distinct meanings for individuals involved and is a dynamic process shaped by social and structural factors. Interventions should therefore respond to the socio-structural influences on injecting drug use initiation by seeking to modify the contexts for initiation, rather than solely prioritizing the reduction of individual

  3. Study on safety analysis of VVER-1200/V491 in scenario of Loss of Coolant Accidents along with partly failure of ECCS using RELAP5 code

    International Nuclear Information System (INIS)

    Hoang Minh Giang; Ha Thi Anh Dao; Hoang Tan Hung; Bui Thi Hoa; Nguyen Thi Tu Oanh; Dinh Anh Tuan; Pham Tuan Nam

    2017-01-01

    The advanced VVER-1200/V491 reactor designed with passive safety systems to deal with design extension conditions is primarily selected as priority candidate for Ninh Thuan 1 nuclear power plant project. So that, in order to enhance competence of nuclear safety and toward participation on review Safety Analysis Report (SAR) of Ninh Thuan nuclear Power project the study on safety analysis of VVER-1200/V491 in scenario of Loss of Coolant Accidents along with partly failure of ECCS is implemented. As requirement of the study, the input deck file of VVER-1200/V491 for RELAP5 and analysis report for some special case of LOCAs along with partly failure of ECCS are issued. (author)

  4. The data analysis of the single well injection-withdraw tracer experiment using the MACRO II

    International Nuclear Information System (INIS)

    Shirakawa, Toshihiko; Kanazawa, Yasuo; Hatanaka, Koichiro

    2001-04-01

    On understanding the radionuclide transport in natural barrier in radioactive waste isolation research, the macroscopic dispersion in heterogeneous permeability field in the underground rock is regarded as an important process. Therefore, we have conducted lots of tracer experiments by the MACRO II facility with an artificially constructed heterogeneous permeability field. In order to study the scale dependence of dispersion coefficients in case of laboratory experiments, we placed the flow cell horizontally, and conducted injection-withdraw tracer experiment with a single well. We have conducted 15 cases experiments. These cases were prepared by changing a position of single well and the injection-withdraw time. At each position we have conducted 9 cases and 6 cases experiments. In this report, we evaluated the macroscopic dispersion coefficients by the fitting of analytical solution to breakthrough curve measured by the 15 cases pumping tracer experiment. Consequently, we could evaluate the dispersion coefficients for 12 cases of 15 cases. Then, we discussed the relation between a injection-withdraw flow rate and a property of heterogeneous media and dispersion coefficient. The conclusions obtained from the results of the evaluation are summarized as follows, It was found that the macroscopic dispersion coefficients tend to be increased with increase of the average radius of tracer front spread around a single well. We have conducted any experiments with s single well settled at two positions. In case of that there is low permeability around a single well, we found dispersion coefficients are large. In case of that there is high permeability around a single well, we found dispersion coefficients are small. In three cases that we could not evaluate because of incorrect accuracy of fitting, we have found it possible that there is some points that dispersion coefficients were strikingly small in tracer front. (author)

  5. Neutral Beam Injection Requirements and Design Issues for the National Compact Stellarator Experiment; TOPICAL

    International Nuclear Information System (INIS)

    H.W. Kugel; H. Neilson; W. Reiersen; M. Zarnstorff

    2002-01-01

    The National Compact Stellarator Experiment (NCSX) will require 6 MW of 50 keV neutral beam injection (NBI) with initial pulse lengths of 500 msec and upgradeable to pulse lengths of 1.5 sec. This paper discusses the NCSX NBI requirements and design issues, and shows how these are provided by the candidate PBX-M[Princeton Beta Experiment-Modification] NBI system

  6. Numerical analysis of experiments with gas injection into liquid metal coolant

    International Nuclear Information System (INIS)

    Usov, E V; Lobanov, P D; Pribaturin, N A; Mosunova, N A; Chuhno, V I; Kutlimetov, A E

    2016-01-01

    Presented paper contains results of a numerical analysis of experiments with gas injection in water and liquid metal which have been performed at the Institute of Thermophysics Russian Academy of Science (IT RAS). Obtained experimental data are very important to predict processes that take place in the BREST-type reactor during the hypothetical accident with damage of the steam generator tubes, and may be used as a benchmark to validate thermo-hydraulic codes. Detailed description of models to simulate transport of gas phase in a vertical liquid column is presented in a current paper. Two-fluid model with closing relation for wall friction and interface friction coefficients was used to simulate processes which take place in a liquid during injection of gaseous phase. It has being shown that proposed models allow obtaining a good agreement between experimental data and calculation results. (paper)

  7. Breakdown pressures and characteristic flaw sizes during fluid injection experiments in shale at elevated confining pressures.

    Science.gov (United States)

    Chandler, M.; Mecklenburgh, J.; Rutter, E. H.; Taylor, R.; Fauchille, A. L.; Ma, L.; Lee, P. D.

    2017-12-01

    Fracture propagation trajectories in gas-bearing shales depend on the interaction between the anisotropic mechanical properties of the shale and the anisotropic in-situ stress field. However, there is a general paucity of available experimental data on their anisotropic mechanical, physical and fluid-flow properties, especially at elevated confining pressures. A suite of mechanical, flow and elastic measurements have been made on two shale materials, the Whitby mudrock and the Mancos shale (an interbedded silt and mudstone), as well as Pennant sandstone, an isotropic baseline and tight-gas sandstone analogue. Mechanical characterization includes standard triaxial experiments, pressure-dependent permeability, brazilian disk tensile strength, and fracture toughness determined using double-torsion experiments. Elastic characterisation was performed through ultrasonic velocities determined using a cross-correlation method. Additionally, we report the results of laboratory-scale fluid injection experiments for the same materials. Injection experiments involved the pressurisation of a blind-ending central hole in a dry cylindrical sample. Pressurisation is conducted under constant volume-rate control, using silicon oils of varying viscosities. Breakdown pressure is not seen to exhibit a strong dependence on rock type or orientation, and increases linearly with confining pressure. In most experiments, a small drop in the injection pressure record is observed at what is taken to be fracture initiation, and in the Pennant sandstone this is accompanied by a small burst of acoustic energy. The shale materials were acoustically quiet. Breakdown is found to be rapid and uncontrollable after initiation if injection is continued. A simplified 2-dimensional model for explaining this is presented in terms of the stress intensities at the tip of a pressurised crack, and is used alongside the triaxial data to derive a characteristic flaw size from which the fractures have initiated

  8. Treatment readiness, attitudes toward, and experiences with methadone and buprenorphine maintenance therapy among people who inject drugs in Malaysia.

    Science.gov (United States)

    Vijay, Aishwarya; Bazazi, Alexander R; Yee, Ilias; Kamarulzaman, Adeeba; Altice, Frederick L

    2015-07-01

    Little is known about attitudes toward and experiences with opioid maintenance therapy (OMT) among people who inject drugs in Malaysia, a country where people who inject drugs comprise 1.3% of the adult population. In 2010, 460 people who inject drugs in Greater Kuala Lumpur, Malaysia were surveyed to evaluate attitudes toward and experiences with OMT and treatment readiness. Attitudes towards OMT with both methadone and buprenorphine were assessed using an opinions scale. Multivariable linear regression was used to assess correlates of treatment readiness, measured with the 19-item Stages of Change Readiness and Treatment Eagerness Scale (SOCRATES). All 460 participants used opioids and nearly all (99.1%) met criteria for opioid dependence. Few had had previous experience with methadone (9.3%) or buprenorphine (12.6%) maintenance therapy, yet many had used methadone (55.2%) or buprenorphine (51.7%) outside of treatment settings. Fifteen percent had injected buprenorphine in the past month, and of the few that were currently receiving buprenorphine maintenance therapy, almost all were injecting it. The majority of subjects exhibited a moderate level of treatment readiness and a preference for methadone over buprenorphine. Those with low treatment readiness scores were more likely to have previous experience with compulsory drug detention centers (polder age (ppeople who inject drugs that may be improved by addressing factors that influence patient attitudes. Those individuals with moderate treatment readiness may be targeted by brief motivational and cognitive interventions in primary care, prisons or OMT clinics aimed at improving entry into and retention in treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Assessment of compliance with regulatory requirements for a best estimate methodology for evaluation of ECCS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Un Chul; Jang, Jin Wook; Lim, Ho Gon; Jeong, Ik [Seoul National Univ., Seoul (Korea, Republic of); Sim, Suk Ku [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2000-03-15

    Best estimate methodology for evaluation of ECCS proposed by KEPCO(KREM) os using thermal-hydraulic best-estimate code and the topical report for the methodology is described that it meets the regulatory requirement of USNRC regulatory guide. In this research the assessment of compliance with regulatory guide. In this research the assessment of compliance with regulatory requirements for the methodology is performed. The state of licensing procedure of other countries and best-estimate evaluation methodologies of Europe is also investigated, The applicability of models and propriety of procedure of uncertainty analysis of KREM are appraised and compliance with USNRC regulatory guide is assessed.

  10. Comparative molecular analysis of early and late cancer cachexia-induced muscle wasting in mouse models.

    Science.gov (United States)

    Sun, Rulin; Zhang, Santao; Lu, Xing; Hu, Wenjun; Lou, Ning; Zhao, Yan; Zhou, Jia; Zhang, Xiaoping; Yang, Hongmei

    2016-12-01

    Cancer-induced muscle wasting, which commonly occurs in cancer cachexia, is characterized by impaired quality of life and poor patient survival. To identify an appropriate treatment, research on the mechanism underlying muscle wasting is essential. Thus far, studies on muscle wasting using cancer cachectic models have generally focused on early cancer cachexia (ECC), before severe body weight loss occurs. In the present study, we established models of ECC and late cancer cachexia (LCC) and compared different stages of cancer cachexia using two cancer cachectic mouse models induced by colon-26 (C26) adenocarcinoma or Lewis lung carcinoma (LLC). In each model, tumor-bearing (TB) and control (CN) mice were injected with cancer cells and PBS, respectively. The TB and CN mice, which were euthanized on the 24th day or the 36th day after injection, were defined as the ECC and ECC-CN mice or the LCC and LCC-CN mice. In addition, the tissues were harvested and analyzed. We found that both the ECC and LCC mice developed cancer cachexia. The amounts of muscle loss differed between the ECC and LCC mice. Moreover, the expression of some molecules was altered in the muscles from the LCC mice but not in those from the ECC mice compared with their CN mice. In conclusion, the molecules with altered expression in the muscles from the ECC and LCC mice were not exactly the same. These findings may provide some clues for therapy which could prevent the muscle wasting in cancer cachexia from progression to the late stage.

  11. Coolant Mixing in a Pressurized Water Reactor: Deboration Transients, Steam-Line Breaks, and Emergency Core Cooling Injection

    International Nuclear Information System (INIS)

    Prasser, Horst-Michael; Grunwald, Gerhard; Hoehne, Thomas; Kliem, Soeren; Rohde, Ulrich; Weiss, Frank-Peter

    2003-01-01

    emergency core cooling (ECC) water entering the RPV through the ECC injection into the cold leg. The experimental results show an incomplete mixing with typical concentration and temperature distributions at the core inlet, which strongly depend on the boundary conditions. Computational fluid dynamics calculations were found to be in good agreement with the experiments

  12. Local Helicity Injection Systems for Non-solenoidal Startup in the PEGASUS Toroidal Experiment

    Science.gov (United States)

    Perry, J. M.; Barr, J. L.; Bongard, M. W.; Fonck, R. J.; Hinson, E. T.; Lewicki, B. T.; Redd, A. J.

    2013-10-01

    Local helicity injection is being developed in the PEGASUS Toroidal Experiment for non-solenoidal startup in spherical tokamaks. The effective loop voltage due to helicity injection scales with the area of the injectors, requiring the development of electron current injectors with areas much larger than the 2 cm2 plasma arc injectors used to date. Solid and gas-effused metallic electrodes were found to be unusable due to reduced injector area utilization from localized cathode spots and narrow operational regimes. An integrated array of 8 compact plasma arc sources is thus being developed for high current startup. It employs two monolithic power systems, for the plasma arc sources and the bias current extraction system. The array effectively eliminates impurity fueling from plasma-material interaction by incorporating a local scraper-limiter and conical-frustum bias electrodes to mitigate the effects of cathode spots. An energy balance model of helicity injection indicates that the resulting 20 cm2 of total injection area should provide sufficient current drive to reach 0.3 MA. At that level, helicity injection drive exceeds that from poloidal induction, which is the relevant operational regime for large-scale spherical tokamaks. Future placement of the injector array near an expanded boundary divertor region will test simultaneous optimization of helicity drive and the Taylor relaxation current limit. Work supported by US DOE Grant DE-FG02-96ER54375.

  13. Industry Application ECCS / LOCA Integrated Cladding/Emergency Core Cooling System Performance: Demonstration of LOTUS-Baseline Coupled Analysis of the South Texas Plant Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Szilard, Ronaldo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Epiney, Aaron [Idaho National Lab. (INL), Idaho Falls, ID (United States); Parisi, Carlo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Vaghetto, Rodolfo [Texas A & M Univ., College Station, TX (United States); Vanni, Alessandro [Texas A & M Univ., College Station, TX (United States); Neptune, Kaleb [Texas A & M Univ., College Station, TX (United States)

    2017-06-01

    Under the auspices of the DOE LWRS Program RISMC Industry Application ECCS/LOCA, INL has engaged staff from both South Texas Project (STP) and the Texas A&M University (TAMU) to produce a generic pressurized water reactor (PWR) model including reactor core, clad/fuel design and systems thermal hydraulics based on the South Texas Project (STP) nuclear power plant, a 4-Loop Westinghouse PWR. A RISMC toolkit, named LOCA Toolkit for the U.S. (LOTUS), has been developed for use in this generic PWR plant model to assess safety margins for the proposed NRC 10 CFR 50.46c rule, Emergency Core Cooling System (ECCS) performance during LOCA. This demonstration includes coupled analysis of core design, fuel design, thermalhydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results. Within this context, a multi-physics best estimate plus uncertainty (MPBEPU) methodology framework is proposed.

  14. Guideline on in-service testing (IST) of ECCS for nuclear power stations in Japan

    International Nuclear Information System (INIS)

    Yamashita, N.; Honjin, M.; Yamazaki, M.; Iwami, H.

    2001-01-01

    In Japan, METI (Ministry of Economy, Trade and Industry) periodic inspections are conducted every 13 months in accordance with the EUIL (Electric Utility Industry Law) for light water reactors. On the other hand, during operation, many kinds of function tests are conducted in accordance with Technical Specifications or utilities voluntary test procedures. However, these maintenance activities during outages are in other respects considered too costly and more than necessary because of its predetermined maintenance interval and its old-fashioned full scope maintenance menu. In these circumstances, the ASME O and M Codes and Standards, which are applied to nuclear power plants in the United States, came to be one of the issues to be considered among Japanese utilities. This is because the ASME O and M Codes and Standards, which are developed to verify the operational readiness of equipment or systems by condition based maintenance or performance testing without overhauls, will be considered to suggest a rational alternative to our existing maintenance activities. Because there had been no standard for function tests other than the METI inspection procedures in Japan, activities started for the development of Japanese Operation and Maintenance Guideline (hereinafter called the Japanese OM Guideline or the Guideline) for function tests and condition monitoring. The Japanese OM Guideline is not proclaimed for regulatory use, but the long-term objective is to provide a substantial basis to change the current maintenance activities including regulatory inspection. The Guideline is composed of five parts, which are general requirements, pumps, valves, snubbers and ECCS systems. This paper gives a summary of the ECCS part of the Japanese OM Guideline, in particular, focusing on the differences between the Guideline and the ASME O and M Standards, and topics or discussion during their establishment. (author)

  15. Modeling injected interstitial effects on void swelling in self-ion irradiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Short, M.P., E-mail: hereiam@mit.edu [Dept. of Nuclear Science and Engineering, Massachusetts Institute of Technology (United States); Gaston, D.R. [Idaho National Laboratory (United States); Jin, M. [Dept. of Nuclear Science and Engineering, Massachusetts Institute of Technology (United States); Shao, L. [Dept. of Nuclear Engineering, Texas A& M University (United States); Garner, F.A. [Radiation Effects Consulting, LLC (United States)

    2016-04-01

    Heavy ion irradiations at high dose rates are often used to simulate slow and expensive neutron irradiation experiments. However, many differences in the resultant modes of damage arise due to unique aspects of heavy ion irradiation. One such difference was recently shown in pure iron to manifest itself as a double peak in void swelling, with both peaks located away from the region of highest displacement damage. In other cases involving a variety of ferritic alloys there is often only a single peak in swelling vs. depth that is located very near the ion-incident surface. We show that these behaviors arise due to a combination of two separate effects: 1) suppression of void swelling due to injected interstitials, and 2) preferential sinking of interstitials to the ion-incident surface, which are very sensitive to the irradiation temperature and displacement rate. Care should therefore be used in collection and interpretation of data from the depth range outside the Bragg peak of ion irradiation experiments, as it is shown to be more complex than previously envisioned. - Highlights: • A model of the spatially dependent point defect kinetics equations with injected interstitials has been implemented. • The results predict a double peak in the void nucleation rate, helping to explain a recent experiment. • The double peak is predicted to be evident within a narrow (+/− 30 °C) temperature window for self-irradiation of pure iron. • The ballistic damage profile may not match the resultant void swelling profile from ion irradiation experiments.

  16. High performance experiments on high pressure supersonic molecular beam injection in the HL-1M tokamak

    International Nuclear Information System (INIS)

    Yao Lianghua; Dong Jiafu; Zhou Yan; Feng Beibing; Cao Jianyong; Li Wei; Feng Zhen; Zhang Jiquan; Hong Wenyu; Cui Zhengying; Wang Enyao; Liu Yong

    2004-01-01

    Supersonic molecular beam injection (SMBI) was first proposed and demonstrated on the HL-1 tokamak and was successfully developed and used on HL-1M. Recently, new results of SMBI experiments were obtained by increasing the gas pressure from 0.5 to over 1.0 MPa. A stair-shaped density increment was obtained with high-pressure multi-pulse SMBI that was similar to the density evolution behaviour during multi-pellet injection. This demonstrated the effectiveness of SMBI as a promising fuelling tool for steady-state operation. The penetration depth and injection speed of the high-pressure SMBI were roughly measured from the contour plot of the Hα emission intensity. It was shown that injected particles could penetrate into the core region of the plasma. The penetration speed of high-pressure SMBI particles in the plasma was estimated to be about 1200 m s -1 . In addition, clusters within the beam may play an important role in the deeper injection. (author)

  17. Post-test analysis of ROSA-III experiment Run 702

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Kikuchi, Osamu; Soda, Kunihisa

    1980-01-01

    The purpose of the ROSA-III experiment with a scaled BWR test facility is to examine primary coolant thermal-hydraulic behavior and performance of ECCS during a posturated loss-of-coolant accident of BWR. The results provide information for verification and improvement of reactor safety analysis codes. Run 702 assumed a 200% split break at the recirculation pump suction line under an average core power without ECCS activation. Post - test analysis of the Run 702 experiment was made with computer code RELAP4J. Agreement of the calculated system pressure and the experiment one was good. However, the calculated heater surface temperatures were higher than the measured ones. Also, the axial temperature distribution was different in tendency from the experimental one. From these results, the necessity was indicated of improving the analytical model of void distribution in the core and the nodalization in the pressure vassel, in order to make the analysis more realistic. And also, the need of characteristic test was indicated for ROSA-III test facility components, such as jet pump and piping form loss coefficient; likewise, flow rate measurements must be increased and refined. (author)

  18. Treatment readiness, attitudes toward, and experiences with methadone and buprenorphine maintenance therapy among people who inject drugs in Malaysia

    Science.gov (United States)

    Vijay, Aishwarya; Bazazi, Alexander R.; Yee, Ilias; Kamarulzaman, Adeeba; Altice, Frederick L.

    2016-01-01

    Background Little is known about attitudes toward and experiences with opioid maintenance therapy (OMT) among people who inject drugs in Malaysia, a country where people who inject drugs comprise 1.3% of the adult population. Methods In 2010, 460 people who inject drugs in Greater Kuala Lumpur, Malaysia were surveyed to evaluate attitudes toward and experience with OMT and treatment readiness. Attitudes towards OMT with both methadone and buprenorphine were assessed using an opinions scale. Multivariable linear regression was used to assess correlates of treatment readiness, measured with the 19-item Stages of Change Readiness and Treatment Eagerness Scale (SOCRATES). Results All 460 participants used opioids and nearly all (99.1%) met criteria for opioid dependence. Few had had previous experience with methadone (9.3%) or buprenorphine (12.6%) maintenance therapy, yet many had used methadone (55.2%) or buprenorphine (51.7%) outside of treatment settings. Fifteen percent had injected buprenorphine in the past month, and of the few that were currently receiving buprenorphine maintenance therapy, almost all were injecting it. The majority of subjects exhibited a moderate level of treatment readiness and a preference for methadone over buprenorphine. Those with low treatment readiness scores were more likely to have previous experience with compulsory drug detention centers (p<0.01), needle/syringe exchange programs (p<0.005), or be of Indian ethnicity (p<0.001). Past use of methadone (p<0.01), older age (p<0.001), stress symptom severity (p<0.001), and sharing of needles or syringes (p<0.05) were associated with higher treatment readiness scores. Conclusion There are suboptimal levels of OMT experience among people who inject drugs that may be improved by addressing factors that influence patient attitudes. Those individuals with moderate treatment readiness may be targeted by brief motivational and cognitive interventions in primary care, prisons or OMT clinics

  19. A Secure ECC-based RFID Mutual Authentication Protocol to Enhance Patient Medication Safety.

    Science.gov (United States)

    Jin, Chunhua; Xu, Chunxiang; Zhang, Xiaojun; Li, Fagen

    2016-01-01

    Patient medication safety is an important issue in patient medication systems. In order to prevent medication errors, integrating Radio Frequency Identification (RFID) technology into automated patient medication systems is required in hospitals. Based on RFID technology, such systems can provide medical evidence for patients' prescriptions and medicine doses, etc. Due to the mutual authentication between the medication server and the tag, RFID authentication scheme is the best choice for automated patient medication systems. In this paper, we present a RFID mutual authentication scheme based on elliptic curve cryptography (ECC) to enhance patient medication safety. Our scheme can achieve security requirements and overcome various attacks existing in other schemes. In addition, our scheme has better performance in terms of computational cost and communication overhead. Therefore, the proposed scheme is well suitable for patient medication systems.

  20. AN ANALYSIS OF STUDENTS’ SPEAKING ABILITY IN ENGLISH CONVERSATION CLUB (ECC PROGRAM AT THE 3rd SEMESTER

    Directory of Open Access Journals (Sweden)

    M. Fadhly Farhy Abbas

    2017-07-01

    Full Text Available This research is based on students’ speaking ability who had followed the EnglishConversation Club (ECC program especially for the third semester of English Department. Thepurpose of this study was to analyze the students’ speaking ability at the 3rd semester in the EnglishConversation Club FKIP UNILAK Pekanbaru. The type of the research was mixed method in typeof explanatory design. The number of participant was 53 students. The researcher used twoinstruments, those were test and interview. In analyzing the data, it used in descriptive statistics.The result of the analysis showed that the average score of 3rd semester students’ speaking abilitywas 45.42. It can be concluded that the students’ speaking ability was categorized into failed . Thescore of Standard Deviation was 7.02, Variance was 49.30, and Range was 36 points . It meansthat the students’ speaking ability was homogeneous. According to the Z-Score, it can be seen that49.06% students’ ability was higher than average and 50.94% students ability was below theaverage. In conclusion, the students’ ability in learning speaking English was failed, it had beenaffected by some factors, those were lack of vocabulary, grammar and motivation. It was supportedby the interview, eventhough the students’ perception to English Conversation Club (ECCprogram was positive, but in fact, the students’ frequency to speak English was seldom, they wereless practice speaking English everyday.Keywords : Speaking , English Conversation Club (ECC

  1. Neutral injection experiments on the ISX-B tokamak

    International Nuclear Information System (INIS)

    Scott, S.D.

    1983-01-01

    The following topics are described: (1) review of confinement scaling in ISX-B with strong neutral injection in clean plasmas, (2) discussion of observed energy confinement improvement in slightly contaminated discharges (factor less than or equal to 2), and (3) preliminary evaluation of confinement with balanced neutral beam injection

  2. First experience with carbon stripping foils for the 160 MeV H- injection into the CERN PSB

    Science.gov (United States)

    Weterings, Wim; Bracco, Chiara; Jorat, Louise; Noulibos, Remy; van Trappen, Pieter

    2018-05-01

    160 MeV H- beam will be delivered from the new CERN linear accelerator (Linac4) to the Proton Synchrotron Booster (PSB), using a H- charge-exchange injection system. A 200 µg/cm2 carbon stripping foil will convert H- into protons by stripping off the electrons. The H- charge-exchange injection principle will be used for the first time in the CERN accelerator complex and involves many challenges. In order to gain experience with the foil changing mechanism and the very fragile foils, in 2016, prior to the installation in the PSB, a stripping foil test stand has been installed in the Linac4 transfer line. In addition, parts of the future PSB injection equipment are also temporarily installed in the Linac4 transfer line for tests with a 160 MeV H- commissioning proton beam. This paper describes the foil changing mechanism and control system, summarizes the practical experience of gluing and handling these foils and reports on the first results with beam.

  3. Effects of upper plenum injection on thermo-hydrodynamic behavior under refill and reflood phases

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Abe, Yutaka; Adachi, Hiromichi; Ohnuki, Akira; Osakabe, Masahiro

    1984-12-01

    In order to investigate the thermo-hydrodynamic behavior in core under simultaneous ECC water injection into the upper plenum and the intact cold leg during the refill and reflood phases of a PWR-LOCA, Tests S1-SH3 and S1-SH4 were performed by using Slab Core Test Facility (SCTF) with the injection of saturated and 67K subcooled water into the upper plenum, respectively, under the same cold leg injection condition. The following major findings were obtained by examining these test results. (1) Although the core was cooled by the fall back water from the upper plenum into the core during the period of high injection rate into the upper plenum, the core was cooled mainly by the bottom flooding after the BOCREC (Bottom of core recovery). (2) The possible fall back flow rate estimated with a CCFL correlation rapidly decreased after the BOCREC because of the increase of steam generation rate in core. (3) Continuous fall back of subcooled water was not observed even under the condition with large upper plenum injection rate of subcooled water and with steam outflow through the lower plenum into the downcomer. The fall back was intermittently limited by the rapid increase of upward steam flow which was generated in the core due to the evaporation of the fall back water. (4) The rising of liquid level in the lower plenum was suppressed by the pressurization in core due to the evaporation of fall back water before the BOCREC and therefore the beginning of bottom reflood was delayed. Some selected data from Tests S1-SH3 and S1-SH4 are also included in this report. (author)

  4. Experience with the new reverse injection scheme in the Tevatron

    International Nuclear Information System (INIS)

    Saritepe, S.; Goderre, G.; Annala, G.; Hanna, B.; Braun, A.

    1993-01-01

    In the new injection scenario the antiproton beam is injected onto a helical Tevatron orbit to avoid the detrimental effects of the beam-beam interaction at 150 GeV. The new scenario required changes in the tuning procedures. Antiprotons are too precious to be used for tuning, therefore the antiproton injection line has to be tuned with protons by reverse injecting them from the Tevatron into the Main Ring. Previously, the reverse injection was performed in one supercycle. One batch of uncoalesced bunches was injected into the Tevatron and ejected after 40 seconds. The orbit closure was performed in the Main Ring. In the new scheme the lambertson magnets have to be moved, separator polarities have to be switched, activities that cannot be completed in one supercycle. Therefore, the reverse injection sequence was changed. This involved the redefinition of TVBS (Tevatron Beam Synchronized Clock) event $D8 as MRBS (Main Ring Beam Synchronized Clock) $D8 thus making it possible to inject 6 proton batches (or coalesced bunches) and eject them one at a time on command, performing orbit closure each time in the Main Ring

  5. Analysis of Cavity Pressure and Warpage of Polyoxymethylene Thin Walled Injection Molded Parts: Experiments and Simulations

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2014-01-01

    Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage...... was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure......, melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number...

  6. Interactive Real-time Simulation of a Nuclear Reactor Emergency Core Cooling System on a Desktop Computer

    International Nuclear Information System (INIS)

    Muncharoen, C.; Chanyotha, S.; Bereznai, G.

    1998-01-01

    The simulation of the Emergency Core Cooling System for a 900 MW nuclear power plant has been developed by using object oriented programming language. It is capable of generating code that executes in real-time on a PENTIUM 100 or equivalent personal computer. Graphical user interface ECCS screens have been developed using Lab VIEW to allow interactive control of ECCS. The usual simulator functions, such as freeze, run, iterate, have been provided, and a number of malfunctions may be activated. A large pipe break near the reactor inlet header has been simulated to verify the response of the ECCS model. LOCA detection, ECC initiation, injection and recovery phased are all modeled, and give results consistent with safety analysis data for a 100% break. With stand alone ECCS simulation, the changes of flow and pressure in ECCS can be observed. The operator can study operational procedures and get used to LOCA in case of the LOCA. Practicing with malfunction, the operator will improve problem solving skills and gain a deeper comprehension of ECCS

  7. Three-dimensional modelling of an injection experiment in the anaerobic part of a landfill plume

    DEFF Research Database (Denmark)

    Juul Petersen, Michael; Engesgaard, Peter Knudegaard; Bjerg, Poul Løgstrup

    1998-01-01

    Analytical and numerical three-dimensional (3-D) simulations have been conducted and compared to data obtained from a large-scale (50 m), natural gradient field injection experiment. Eighteen different xenobiotic compounds (i.e. benzene, toluene, o-xylene, naphthalene, 1,1,1-TCA, PCE, and TCE...

  8. Field experience on Zn injection on PWR plants with a view to dose rate reduction

    International Nuclear Information System (INIS)

    Roumiguiere, F.

    2005-01-01

    Operating experience acquired at PWR plants shows that zinc injection in the primary coolant at low concentration (∼5 ppb) is a very effective tool to achieve a reduction of the dose rate build-up. The beneficial effect of zinc consists on improving the protective layer characteristics of the reactor coolant system surfaces, which results in a lower pickup of activated products (Co-60, Co-58), and consequently a reduction of the associated dose rates. Zinc injection was introduced at the Unit B of the Biblis Power Station in September 1996 and at the Obrigheim Nuclear Power Station in February 1998, as a measure for reduction of radiation fields. The effectiveness of the method and its compatibility with the overall plant was examined in a rather comprehensive surveillance program at these plants. The already published data show that zinc injection did not lead to any operating restrictions or other negative effects on plants systems and components. Zinc injection is still being implemented today at these plants. Zinc injection is considered today as a mature technique and is now being successfully applied at a number of PWRs in Germany, Brazil, USA and Japan, with the support of Framatome-ANP. Several PWRs in Europe and Asia are preparing for zinc chemistry in the near future. The method is inexpensive and easy to apply. Its implementation is highly advisable in terms of the cost/benefit criterion following the ALARA principle. This paper gives an overview of the experience gathered with the method. The main subject addressed by the paper is the evolution of dose rates at the primary system and work-related doses since introduction of the method. In German PWRs with Incoloy 800 steam generator tubing material (Ni-content ∼32%), the observed reductions correspond to a decrease in dose rates of around 10 to 15% per year following, as predicted, the half-life time of 60 Co. Overall reductions in high radiation areas are now in the range of 50% after 5 years of

  9. Correlated electron capture in the impact parameter and final projectile charge-state dependence of ECC cusp production in 0.53 MeV u-1 F8+ + Ne

    International Nuclear Information System (INIS)

    Skutlartz, A.; Hagmann, S.; Schmidt-Boecking, H.

    1988-01-01

    The impact parameter dependence of ECC cusp electron production in collisions of fast, highly charged ions with atoms is investigated by measuring the scattered projectiles in coincidence with cusp electrons emitted at 0 0 with respect to the beam axis. The absolute probabilities for ECC cusp production show a maximum at b ≅ 0.10 au, decrease strongly for smaller impact parameters and more gently toward larger impact parameters. In addition the final charge state of the scattered projectile is also determined simultaneously for each collision event. The probabilities, as a function of the projectile final charge state, are large for the case where at least one or more electrons are simultaneously captured into bound states of the projectile, but are surprisingly small for collisions in which a projectile did not capture an electron into a bound state. (author)

  10. Operational experience of the upgraded LHC injection kicker magnets during Run 2 and future plans

    Science.gov (United States)

    Barnes, M. J.; Adraktas, A.; Bregliozzi, G.; Goddard, B.; Ducimetière, L.; Salvant, B.; Sestak, J.; Vega Cid, L.; Weterings, W.; Vallgren, C. Yin

    2017-07-01

    During Run 1 of the LHC, one of the injection kicker magnets caused occasional operational delays due to beam induced heating with high bunch intensity and short bunch lengths. In addition, there were also sporadic issues with vacuum activity and electrical flashover of the injection kickers. An extensive program of studies was launched and significant upgrades were carried out during Long Shutdown 1 (LS 1). These upgrades included a new design of beam screen to reduce both beam coupling impedance of the kicker magnet and the electric field associated with the screen conductors, hence decreasing the probability of electrical breakdown in this region. This paper presents operational experience of the injection kicker magnets during the first years of Run 2 of the LHC, including a discussion of faults and kicker magnet issues that limited LHC operation. In addition, in light of these issues, plans for further upgrades are briefly discussed.

  11. A study on design improvement of the emergency core cooling system for a nuclear ship reactor

    International Nuclear Information System (INIS)

    Naruko, Yoshinori

    1982-01-01

    ECCS performances are predicted for the N.S. ''MUTSU'' Reactor using new computing techniques. The actual performances are found to be inadequate with regard to the total injection flow rate and the infection head of the High Pressure Injection System (HPIS). The actual Safety Injection (SI) Signal is also shown to be inoperative in a gas phase LOCA. Because of this fact, the ECCS has been improved by replacing the existing HPIS with two large high pressure pumps and by adding ''Reactor Pressure Low-Low'' and ''Containment Pressure High'' signals. This report deals with a numerical study of the dynamical behavior of the N.S. MUTSU Reactor in the postulated small break LOCA, which has been calculated to verify the design improvement by evaluating the new ECCS performances on the basis of RELAP4/MOD6/SUS and TOODEE2/SUS codes. In conclusion, the improved system performs satisfactorily in the whole range of gas phase breaks and in the small break range of liquid phase LOCA. (author)

  12. Mitomycin C-augmented trabeculectomy: subtenon injection versus soaked sponges: a randomised clinical trial.

    Science.gov (United States)

    Pakravan, Mohammad; Esfandiari, Hamed; Yazdani, Shahin; Douzandeh, Azadeh; Amouhashemi, Nassim; Yaseri, Mehdi; Pakravan, Parto

    2017-09-01

    To compare the efficacy and safety of subtenon injection of mitomycin C (MMC) with that of conventional application of MMC-soaked sponges in trabeculectomy. In this multicentre randomised clinical trial, 80 consecutive open-angle glaucoma cases were randomised into two groups; group 1 received a subtenon injection of 0.1 mL of 0.01% MMC, while group 2 received 0.02% MMC-soaked sponges. Primary outcome measure was intraocular pressure (IOP), and secondary outcome measures were endothelial cell count (ECC) changes and bleb morphology according to the Indiana Bleb Appearance Grading Scale. Outcome measures were compared at 1, 3 and 6 months postoperatively. Complete and qualified success was defined as IOP within 6-15 mm Hg without and with medications at month 6, respectively. Mean preoperative IOP was 21.8±5.1 in group 1, which reduced to 10.3±3.7 mm Hg at final visit (pinjection of MMC is a safe and effective alternative to the conventional soaked sponge method. This method produces more favourable bleb morphology after trabeculectomy. NCT02385370, Post-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. UPTF/TEST10B/RUN081, Steam/Water Flow Phenomena Reflood PWR Cold Leg Break LOCA

    International Nuclear Information System (INIS)

    1998-01-01

    hot leg region of a PWR which may occur in the reflood phase during a large cold leg break LOCA with cold leg ECC injection. Boundary Conditions: There was no ECC injection. Steam and saturated water were injected into the core simulator. The cold leg break valve was open. The hot leg break valve and all pump simulators were partially open to establish the desired loop flow resistances. Significant Findings: During an initial time period - about 40 s - the water that was injected into the core simulator was distributed within the upper plenum and the adjacent loops. After these regions were 'saturated' with water, the water was carried by the steam into the steam generator simulator inlet plenum and into the cyclones of these simulators where it was separated. The amount of water separated by the cyclones in the steam generator simulators was in good agreement with the amount of water injected into the core simulator after the initial time period of about 40 s. After termination of the steam injection into the core simulator, the water flow back into the core region was in quantitative agreement with the amount of water that was distributed during the initial time periods. During the entire test phase there was no significant pool formation above the tie plate. 3 - Experimental limitations or shortcomings: The system operating pressure was limited to 20 bar. So for some experiments pressure scaling was necessary

  14. Pellet injection in a tokamak hot plasma. Theory and experiment

    International Nuclear Information System (INIS)

    Picchiottino, J.M.

    1994-01-01

    The ultimate aim of pellet ablation studies is to predict what the plasma temperature and density profiles are just after a pellet injection. This requires description of the pellet ablation process, the parallel expansion of the ablatant and the fast outward motion of the deposited material since these three phenomena successively occur from the time of pellet injection to the moment when new axisymmetric profiles are reached. Only the two first points have been quantitatively modelled. If the most important processes of ablation physics are identified and although current models reproduce both measured penetrations and averaged characteristics of ablation clouds, some debatable points remain, mainly bearing on the drifts associated with the pellet motion and, consequently, on the effective shielding efficiency of the ionized part of the ablation cloud. During its parallel expansion, the ablated material experiences a strong poloidal rotation which depends on the ratio of the pellet and plasma masses and is due to the total kinetic momentum conservation on each magnetic surface. The fact that this rotation occurs on the same timescale as the outward motion suggests that both phenomena can be linked and that a comprehensive model of the whole fuelling process may emerge from considering the pellet and the plasma as a unique system. (author). 94 refs., 142 figs., 4 annexes

  15. Incarceration experiences among a community-recruited sample of injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Lai Calvin

    2009-12-01

    Full Text Available Abstract Background Since 2003 Thailand has waged an aggressive "war on drugs" campaign focused on arresting and incarcerating suspected drug users and dealers. However, little is known about incarceration experiences among IDU in the wake of the recent war on drugs. Therefore, we sought to examine incarceration experiences among IDU in Bangkok, Thailand. Methods We examined the prevalence of incarceration among community-recruited IDU participating in the Mitsampan Community Research Project. Multivariate logistic regression was used to identify factors associated with a self-reported history of incarceration. We also examined the prevalence of injection drug use and syringe sharing within prisons. Results 252 IDU were recruited in August 2008; 66 (26.2% were female and the median age was 36.5 years. In total, 197 (78.2% participants reported a history of incarceration. In multivariate analyses, reporting a history of incarceration was associated with a history of compulsory drug treatment (adjusted odds ratio [AOR] = 4.93; 95% confidence interval [CI]: 1.95 - 12.48, non-fatal overdose (AOR = 3.69; 95%CI: 1.45 - 9.39, syringe sharing (AOR = 2.20; 95%CI: 1.12 - 4.32, and female gender (AOR = 0.41; 95%CI: 0.20 - 0.82. Among those who reported a history of incarceration, 59 (29.9% reported injection drug use in prison, and 48 (81.4% of these individuals reported sharing syringes in prison. Incarceration was not associated with the number of injections performed in the previous week (p = 0.202. Conclusion Over three-quarters of the IDU participating in this study reported a history of incarceration, and 30% of these individuals reported injection drug use within prison. Further, an alarmingly high level of syringe sharing within prison was reported, and incarceration was not associated with reductions in drug use. These findings provide further evidence of the need for community diversion strategies, as well as harm reduction programs, in Thai

  16. TRAC-PF1 code assessment using OECD LOFT LP-FP-1 experiment

    International Nuclear Information System (INIS)

    Barbero, F.J.

    1992-04-01

    This report assesses thermal-hydraulic aspects of LOFT LP-FP-1 experiment making use of TRAC-PF1/MOD1. LP-FP-1 experiment studies the system thermal-hydraulic and core thermal response for initial and boundary conditions similar to a large-break design basis LOCA leading to fission product release from the fuel cladding gap region. It also assesses the fission product retention effectiveness of the PWR-ECCS in best estimate conditions

  17. Zinc injection on the EDF pressurized light water reactors. Current results and operating experience feedback

    International Nuclear Information System (INIS)

    Piana, Olivier; Duval, Arnaud; Moleiro, Edgar; Benfarah, Moez; Bretelle, Jean-Luc; Chaigne, Guy

    2014-01-01

    Nowadays, zinc injection, as well as pH management and hydrogen control, is increasingly considered as an essential element of PWR Primary Water Chemistry worldwide. After a first implementation of zinc injection at Bugey 2 since 2004 and Bugey 4 since 2006, EDF decided to extend this practice, which constitutes a modification of primary circuit chemical conditioning, to other units of its fleet. Currently, 15 among the 58 reactors of the French fleet are injecting depleted zinc acetate into the primary coolant water. Three main goals were identified at the beginning of this program. Indeed, the expected benefits of zinc injection were: Reduction of the rate of generalized corrosion and mitigation of stress corrosion cracking initiation on nickel based alloys (Material goal). Curative or preventive reduction of radiation sources to which workers are exposed (Radiation fields' goal). Mitigation of the AOA or CIPS risks by reduction of corrosion products releases and mitigation of crud deposition (Fuel protection goal). To monitor the zinc addition, EDF has defined a complete survey program concerning: chemistry and radiochemistry responses (primary coolant monitoring of corrosion and fission products and calculation of zinc injected, zinc removed and zinc incorporated in RCS surfaces) ; radiation fields (dose rates and deposited activities measurements) ; materials (statistical analysis of SG tube cracks) ; fuel (oxide thickness measurements and visual exams) ; effluents (corrosion products releases and isotopic distribution follow up) ; wastes (radiochemical characterization of filters). This paper will detail the present results of this monitoring program. It appears that the expected benefits of zinc injection have yet to be fully realized; further operating experience will be required in order to fully evaluate its impact. (author)

  18. Effects of Streptomycin Administration on Increases in Skeletal Muscle Fiber Permeability and Size Following Eccentric Muscle Contractions.

    Science.gov (United States)

    Hayao, Keishi; Tamaki, Hiroyuki; Nakagawa, Kouki; Tamakoshi, Keigo; Takahashi, Hideaki; Yotani, Kengo; Ogita, Futoshi; Yamamoto, Noriaki; Onishi, Hideaki

    2018-06-01

    The purpose of this study was to investigate the preventive effect of streptomycin (Str) administration on changes in membrane permeability and the histomorphological characteristics of damaged muscle fibers following eccentric contraction (ECC ). Eighteen 7-week-old male Fischer 344 rats were randomly assigned to three groups: control (Cont), ECC, and ECC with Str (ECC + Str). The tibialis anterior (TA) muscles in both ECC groups were stimulated electrically and exhibited ECC. Evans blue dye (EBD), a marker of muscle fiber damage associated with increased membrane permeability, was injected 24 hr before TA muscle sampling. The number of EBD-positive fibers, muscle fiber cross-sectional area (CSA), and roundness were determined via histomorphological analysis. The ECC intervention resulted in an increased fraction of EBD-positive fibers, a larger CSA, and decreased roundness. The fraction of EBD-positive fibers was 79% lower in the ECC + Str group than in the ECC group. However, there was no difference in the CSA and roundness of the EBD-positive fibers between the two ECC groups. These results suggest that Str administration can reduce the number of myofibers that increase membrane permeability following ECC, but does not ameliorate the extent of fiber swelling in extant EBD-positive fibers. Anat Rec, 301:1096-1102, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  19. "Injection first": a unique group of injection drug users in Tijuana, Mexico.

    Science.gov (United States)

    Morris, Meghan D; Brouwer, Kimberly C; Lozada, Remedios M; Gallardo, Manuel; Vera, Alicia; Strathdee, Steffanie A

    2012-01-01

    Using baseline data from a study of injection drug users (IDUs) in Tijuana, Mexico (N = 1,052), we identified social and behavioral factors associated with injecting at the same age or earlier than other administration routes of illicit drug use (eg, "injection first") and examined whether this IDU subgroup had riskier drug using and sexual behaviors than other IDUs. Twelve-percent "injected first." Characteristics independently associated with a higher odds of "injection first" included being younger at first injection, injecting heroin as their first drug, being alone at the first injection episode, and having a sexual debut at the same age or earlier as when they initiated drug use; family members' illicit drug use was associated with lower odds of injecting first. When adjusting for age at first injection and number of years injecting, "injection first" IDUs had lower odds of ever overdosing, and ever trading sex. On the other hand, they were less likely to have ever been enrolled in drug treatment, and more commonly obtained their syringes from potentially unsafe sources. In conclusion, a sizable proportion of IDUs in Tijuana injected as their first drug using experience, although evidence that this was a riskier subgroup of IDUs was inconclusive.  Copyright © American Academy of Addiction Psychiatry.

  20. Plasma jet source parameter optimisation and experiments on injection into Globus-M spherical tokamak

    International Nuclear Information System (INIS)

    Gusev, V.K.; Petrov, Yu.V.; Sakharov, N.V.; Semenov, A.A.; Voronin, A.V.

    2005-01-01

    Results of theoretical and experimental research on the plasma sources and injection of plasma and gas jet produced by the modified source into tokamak Globus-M are presented. An experimental test stand was developed for investigation of intense plasma jet generation. Optimisation of pulsed coaxial accelerator parameters by means of analytical calculations is performed with the aim of achieving the highest flow velocity at limited coaxial electrode length and discharge current. The optimal parameters of power supply to generate a plasma jet with minimal impurity contamination and maximum flow velocity were determined. A comparison of experimental and calculation results is made. Plasma jet parameters are measured, such as: impurity species content, pressure distribution across the jet, flow velocity, plasma density, etc. Experiments on the interaction of a higher kinetic energy plasma jet with the magnetic field and plasma of the Globus-M tokamak were performed. Experimental results on plasma and gas jet injection into different Globus-M discharge phases are presented and discussed. Results are presented on the investigation of plasma jet injection as the source for discharge breakdown, plasma current startup and initial density rise. (author)

  1. ATX-101 (Deoxycholic Acid Injection) Treatment in Men: Insights From Our Clinical Experience.

    Science.gov (United States)

    Shridharani, Sachin M; Behr, Kathleen L

    2017-11-01

    Excess submental fat (SMF), also called a double chin, is an area of concern for men that can be addressed clinically. ATX-101 (deoxycholic acid injection; Kybella in the United States and Belkyra in Canada, Australia, and various European countries) is the first injectable approved for reduction of SMF. To share the authors' clinical experience using ATX-101 in men with submental fullness and offer insights regarding how this treatment may be presented to men as an option to improve their submental profile. Retrospective review of the authors' medical records for male patients treated with ATX-101. To allow for fewer ATX-101 treatments, it is recommended that a large surface area be treated at the first session. The positive changes and outcomes achieved with ATX-101 build confidence between the physician and patient, which often leads to male patients seeking other aesthetic treatments to improve their overall appearance. ATX-101 treatment is often an effective introduction to aesthetic medicine for men.

  2. Experimental investigation of void distribution in Suppression Pool during the initial blowdown period of a Loss of Coolant Accident using air–water two-phase mixture

    International Nuclear Information System (INIS)

    Rassame, Somboon; Griffiths, Matthew; Yang, Jun; Lee, Doo Yong; Ju, Peng; Choi, Sung Won; Hibiki, Takashi; Ishii, Mamoru

    2014-01-01

    Highlights: • Basic understanding of the venting phenomena in the SP during a LOCA was obtained. • A series of experiment is carried out using the PUMA-E test facility. • Two phases of experiments, namely, an initial and a quasi-steady phase were observed. • The maximum void penetration depth was experienced during the initial phase. - Abstract: During the initial blowdown period of a Loss of Coolant Accident (LOCA), the non-condensable gas initially contained in the BWR containment is discharged to the pressure suppression chamber through the blowdown pipes. The performance of Emergency Core Cooling System (ECCS) can be degraded due to the released gas ingestion into the suction intakes of the ECCS pumps. The understanding of the relevant phenomena in the pressure suppression chamber is important in analyzing potential gas intrusion into the suction intakes of ECCS pumps. To obtain the basic understanding of the relevant phenomena and the generic data of void distribution in the pressure suppression chamber during the initial blowdown period of a LOCA, tests with various blowdown conditions were conducted using the existing Suppression Pool (SP) tank of the integral test facility, called Purdue University Multi-Dimensional Integral Test Assembly for ESBWR applications (PUMA-E) facility, a scaled downcomer pipe installed in the PUMA-E SP, and air discharge pipe system. Two different diameter sizes of air injection pipe (0.076 and 0.102 m), a range of air volumetric flux (7.9–24.7 m/s), initial void conditions in an air injection pipe (fully void, partially void, and fully filled with water) and different air velocity ramp rates (1.0, 1.5, and 2.0 s) are used to investigate the impact of the blowdown conditions to the void distribution in the SP. Two distinct phases of experiments, namely, an initial and a quasi-steady phase were observed. The maximum void penetration depth was experienced during the initial phase. The quasi-steady phase provided less void

  3. Early results of microwave transmission experiments through an overly dense rectangular plasma sheet with microparticle injection

    Energy Technology Data Exchange (ETDEWEB)

    Gillman, Eric D., E-mail: eric.gillman.ctr@nrl.navy.mil [National Research Council Postdoctoral Associate at the U.S. Naval Research Laboratory, Washington, DC 20375 (United States); Amatucci, W. E. [U.S. Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-06-15

    These experiments utilize a linear hollow cathode to create a dense, rectangular plasma sheet to simulate the plasma layer surrounding vehicles traveling at hypersonic velocities within the Earth's atmosphere. Injection of fine dielectric microparticles significantly reduces the electron density and therefore lowers the electron plasma frequency by binding a significant portion of the bulk free electrons to the relatively massive microparticles. Measurements show that microwave transmission through this previously overly dense, impenetrable plasma layer increases with the injection of alumina microparticles approximately 60 μm in diameter. This method of electron depletion is a potential means of mitigating the radio communications blackout experienced by hypersonic vehicles.

  4. Suppression of Alfven Modes on the National Spherical Torus Experiment Upgrade with Outboard Beam Injection [Suppression of Alfven Modes on the NSTX-U with Outboard Beam Injection

    International Nuclear Information System (INIS)

    Fredrickson, E. D.; Belova, E. V.; Battaglia, D. J.

    2017-01-01

    In this paper we present data from experiments on the National Spherical Torus Experiment Upgrade, where it is shown for the first time that small amounts of high pitch-angle beam ions can strongly suppress the counterpropagating global Alfven eigenmodes (GAE). GAE have been implicated in the redistribution of fast ions and modification of the electron power balance in previous experiments on NSTX. The ability to predict the stability of Alfven modes, and developing methods to control them, is important for fusion reactors like the International Tokamak Experimental Reactor, which are heated by a large population of nonthermal, super-Alfvenic ions consisting of fusion generated alpha's and beam ions injected for current profile control. We present a qualitative interpretation of these observations using an analytic model of the Doppler-shifted ion-cyclotron resonance drive responsible for GAE instability which has an important dependence on k(perpendicular to rho L). A quantitative analysis of this data with the HYM stability code predicts both the frequencies and instability of the GAE prior to, and suppression of the GAE after the injection of high pitch-angle beam ions.

  5. Particle balance studies in TEXTOR during experiments of pellet injection, helium injection, and ICR-heating

    International Nuclear Information System (INIS)

    Banno, T.; Finken, K.H.; Gray, D.S.; Winter, J.

    1995-01-01

    Analysis based on the particle conservation law has been carried out to observe the global fuelling process in tokamak discharges. The response of the net recycling flux from the first wall is investigated in the tokamak TEXTOR, using calibrated signals of the gas feed rate, the neutral gas pressure in the vessel, the total amount of electrons, and the particle removal rates by the ALT-II belt-pump limiter and by a main pump unit. Net absorption (pumping) of hydrogen by the wall is observed for almost all tokamak discharges since a new wall conditioning technique called siliconisation is employed. The net absorption or fuelling depending on the discharge condition influenced by injection of pellets, by helium gas injection combined with neutral beam injection, and by rf heating can be interpreted in terms of the particle-induced desorption effect with depth profile taken into consideration. ((orig.))

  6. Identification of temperature-dependent water quality changes during a deep well injection experiment in a pyritic aquifer

    NARCIS (Netherlands)

    Prommer, H.; Stuijfzand, P.J.

    2005-01-01

    Artificial recharge is a technique used increasingly to supplement drinking water supplies. To assess the potential water quality changes that occur during subsurface passage, a comprehensive deep-well injection experiment was carried out for a recharge scheme, where pretreated, aerobic surface

  7. Efficient Spin Injection into Semiconductor

    International Nuclear Information System (INIS)

    Nahid, M.A.I.

    2010-06-01

    Spintronic research has made tremendous progress nowadays for making future devices obtain extra advantages of low power, and faster and higher scalability compared to present electronic devices. A spintronic device is based on the transport of an electron's spin instead of charge. Efficient spin injection is one of the very important requirements for future spintronic devices. However, the effective spin injection is an exceedingly difficult task. In this paper, the importance of spin injection, basics of spin current and the essential requirements of spin injection are illustrated. The experimental technique of electrical spin injection into semiconductor is also discussed based on the experimental experience. The electrical spin injection can easily be implemented for spin injection into any semiconductor. (author)

  8. Best estimate small break LOCA analysis for KNGR SIS optimization

    International Nuclear Information System (INIS)

    Song, JIn Ho; Lim, Hong Sik; Bae, Kyoo Hwan; Lee, Joon

    1996-01-01

    The KNGR has an advanced ECCS design feature which employs four mechanically-separated SI trains where each train consisting of one HPSI pump and one SIT injects ECC water directly into the reactor vessel downcomer annulus. To demonstrate that the KNGR ECCS design features meet the EPRI ALWR requirements of no core uncovery for a break of up to 6 inch diameter, small break LOCA cases with various break sizes were analyzed using a best-estimate analytical procedure. Two kinds of break locations are considered: cold leg and DVI line breaks. It was observed that the KNGR ECCS design can tolerate a cold leg break of up to 10 inches with no core uncovery. However, since DVI line break with 6 inch diameter undergoes slight core uncovery, further investigation is required for KNGR SIS optimization

  9. Pressure tube type reactors

    International Nuclear Information System (INIS)

    Komada, Masaoki.

    1981-01-01

    Purpose: To increase the safety of pressure tube type reactors by providing an additional ECCS system to an ordinary ECCS system and injecting heavy water in the reactor core tank into pressure tubes upon fractures of the tubes. Constitution: Upon fractures of pressure tubes, reduction of the pressure in the fractured tubes to the atmospheric pressure in confirmed and the electromagnetic valve is operated to completely isolate the pressure tubes from the fractured portion. Then, the heavy water in the reactor core tank flows into and spontaneously recycles through the pressure tubes to cool the fuels in the tube to prevent their meltdown. By additionally providing the separate ECCS system to the ordinary ECCS system, fuels can be cooled upon loss of coolant accidents to improve the safety of the reactors. (Moriyama, K.)

  10. Design calculations for a combined ventilation and brine injection experiment at the Grimsel Rock Laboratory, Switzerland

    International Nuclear Information System (INIS)

    Finsterle, S.; Pruess, K.

    1993-07-01

    A combined ventilation and brine injection test is planned at the Grimsel Test Site. The objective of the experiment is to study the transport of liquid and gas in the vicinity of a ventilated drift in order to evaluate the impact of the drying process on the characterization of the rock matrix. The proposed test sequence includes a desaturation-resaturation cycle. In addition, brine and fresh water will be injected from a borehole as trace electrolytes in order to better track the propagation of the individual phases. Results of design calculations using the TOUGH2 code show that injection of brine may significantly influence the unsaturated flow behavior by changing the pressure and saturation distribution around the borehole. Transport velocity is predicted to be very slow, requiring several months for the brine to reach the draft wall. However, the presence of preferential flow paths may reduce travel time and alter brine content and saturation distribution so that certain sensors may respond earlier or not at all

  11. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  12. Emulsion sheet doublets as interface trackers for the OPERA experiment

    CERN Document Server

    Anokhina, A.; Ariga, A.; Arrabito, L.; Autiero, D.; Badertscher, A.; Bay, F.; Greggio, F.Bersani; Bertolin, A.; Besnier, M.; Bick, D.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Carrara, E.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Consiglio, L.; Cozzi, M.; Cuha, V.; Dal Corso, F.; D'Amato, G.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Di Troia, C.; Dmitrievski, S.; Dominjon, A.; Dracos, Marcos; Duchesneau, D.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, Antonio; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Frekers, D.; Fukuda, T.; Galkin, V.I.; Galkin, V.A.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Goldberg, J.; Golubkov, D.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gusev, G.; Gustavino, C.; Hagner, Caren; Hara, T.; Hierholzer, M.; Hiramatsu, S.; Hoshino, Kaoru; Ieva, M.; Jakovcic, K.; Janicsko Csathy, J.; Janutta, B.; Jollet, C.; Juget, F.; Kawai, T.; Kazuyama, M.; Kim, S.H.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laktineh, I.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, Andrea; Lutter, G.; Manai, K.; Mandrioli, G.; Marotta, A.; Marteau, J.; Matsuo, T.; Matsuoka, H.; Mauri, N.; Meisel, F.; Meregaglia, A.; Messina, M.; Migliozzi, P.; Mikado, S.; Miyamoto, S.; Monacelli, Piero; Morishima, Kunihiro; Moser, U.; Muciaccia, Maria Teresa; Naganawa, N.; Naka, T.; Nakamura, M.; Nakamura, T.; Nakano, T.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Osedlo, V.; Ossetski, D.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pilipenko, V.; Pistillo, C.; Polukhina, N.; Pozzato, M.; Pretzl, Klaus P.; Publichenko, P.; Pupilli, F.; Roganova, T.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryazhskaya, O.; Ryzhikov, D.; Sato, O.; Sato, Y.; Saveliev, V.; Sazhina, G.; Schembri, A.; Scotto Lavina, L.; Shibuya, H.; Simone, S.; Sioli, Max; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, Paolo Emilio; Sugonyaev, V.; Taira, Y.; Takahashi, S.; Tenti, M.; Terranova, F.; Tezuka, I.; Tioukov, V.; Tolun, P.; Tsarev, V.; Tufanli, S.; Ushida, N.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Wurtz, J.; Yoon, C.S.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, Amina; Zimmermann, R.

    2008-01-01

    New methods for efficient and unambiguous interconnection between electronic counters and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment, that aims at detecting oscillations between mu neutrino and tau neutrino in the CNGS neutrino beam, is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector, on-site large-scale treatments of the emulsions ("refreshing") have been applied. Changeable Sheet (CSd) packages, each made of a doublet of emulsion films, have been designed, assembled and coupled to the OPERA target units ("ECC bricks"). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronic...

  13. Dynamic investigation of nutrient consumption and injection strategy in microbial enhanced oil recovery (MEOR) by means of large-scale experiments.

    Science.gov (United States)

    Song, Zhiyong; Zhu, Weiyao; Sun, Gangzheng; Blanckaert, Koen

    2015-08-01

    Microbial enhanced oil recovery (MEOR) depends on the in situ microbial activity to release trapped oil in reservoirs. In practice, undesired consumption is a universal phenomenon but cannot be observed effectively in small-scale physical simulations due to the scale effect. The present paper investigates the dynamics of oil recovery, biomass and nutrient consumption in a series of flooding experiments in a dedicated large-scale sand-pack column. First, control experiments of nutrient transportation with and without microbial consumption were conducted, which characterized the nutrient loss during transportation. Then, a standard microbial flooding experiment was performed recovering additional oil (4.9 % Original Oil in Place, OOIP), during which microbial activity mostly occurred upstream, where oil saturation declined earlier and steeper than downstream in the column. Subsequently, more oil remained downstream due to nutrient shortage. Finally, further research was conducted to enhance the ultimate recovery by optimizing the injection strategy. An extra 3.5 % OOIP was recovered when the nutrients were injected in the middle of the column, and another additional 11.9 % OOIP were recovered by altering the timing of nutrient injection.

  14. Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

    Directory of Open Access Journals (Sweden)

    Li Yuquan

    2017-02-01

    Full Text Available The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA, the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the

  15. Comparative experiments to assess the effects of accumulator nitrogen injection on passive core cooling during small break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Li, YuQuan; Hao, Botao; Zhong, Jia; Wan Nam [State Nuclear Power Technology R and D Center, South Park, Beijing Future Science and Technology City, Beijing (China)

    2017-02-15

    The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME)—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative

  16. Prompt Loss of Energetic Ions during Early Neutral Beam Injection in the National Spherical Torus Experiment

    International Nuclear Information System (INIS)

    Medley, S.S.; Darrow, D.S.; Liu, D.; Roquemore, A.L.

    2005-01-01

    Early neutral-beam injection is used in the National Spherical Torus Experiment (NSTX) to heat the electrons and slow current penetration which keeps q(0) elevated to avoid deleterious MHD activity and at the same time reduces Ohmic flux consumption, all of which aids long-pulse operation. However, the low plasma current (I p ∼ 0.5 MA) and electron density (n e ∼ 1 x 10 13 cm -3 ) attending early injection lead to elevated orbit and shine through losses. The inherent orbit losses are aggravated by large excursions in the outer gap width during current ramp-up. An investigation of this behavior using various energetic particle diagnostics on NSTX and TRANSP code analysis is presented

  17. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    Experiences with injecting geothermal fluids have identified technical problems associated with geothermal waste disposal. This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented, including: Raft River, Salton Sea, East Mesa, Otake and Hatchobaru in Japan, and Ahuachapan in El Salvador. Hydrogeologic and design/operational factors affecting the success of an injection program are identified. Hydrogeologic factors include subsidence, near-surface effects of injected fluids, and seismicity. Design/operational factors include hydrodynamic breakthrough, condition of the injection system and reservoir maintenance. Existing and potential effects of production/injection on these factors are assessed.

  18. Data report for ROSA-IV LSTF 10% hot leg break experiment Run SB-HL-04

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Nakamura, Hideo; Saeki, Hiroyuki

    1991-03-01

    Experimental data for the 10% hot leg break test, Run SB-HL-04, conducted on March 29, 1988 at the ROSA-IV Large Scale Test Facility (LSTF), are presented. This test was conducted as part of test series which studied the effect of break orientation on 10% hot leg break transient, and represented a vertical upward break. Other two tests in this test series represented horizontal break and vertical downward break, respectively. The results of these tests were characterized by asymmetric loop responses, flashing in the cold legs as well as upper downcomer, and condensation depressurization in the cold legs following injection of emergency core coolant (ECC) from accumulators. (author)

  19. Electron beam injection during active experiments. 1. Electromagnetic wave emissions

    International Nuclear Information System (INIS)

    Winglee, R.M.; Kellogg, P.J.

    1990-01-01

    During the active injection of an electron beam, a broad spectrum of waves is generated. In this paper examples of spectra from the recent Echo 7 experiment are presented. These results show that the characteristics of the emissions can change substantially with altitude. Two-dimensional (three velocity) relativistic electromagnetic particle simulations are used to investigate the changes in the plasma conditions required to account for the observed spectral variations. It is shown that many of these variations can be accounted for by assuming that the ratio of the electron plasma frequency ω pe to cyclotron frequency Ω e is less than unity at the lower altitudes of about 200 km and near or above unity at apogee of about 300 km. In the former case, whistlers with a cutoff at ω pe , lower hybrid and plasma waves are driven by the parallel beam energy while electromagnetic fundamental z mode and second harmonic x mode and electrostatic upper hybrid waves are driven by the perpendicular beam energy through the master instability. E x B drifts driven by perpendicular electric fields associated with the beam-plasma interaction can also be important in generating maser emission, particularly for field-aligned injection where there is no intrinsic perpendicular beam energy. The power in the electrostatic waves is a few percent of the beam energy and that in the electromagnetic waves a few tenths of a percent. In the latter case, where ω pe /Ω e increases above unity, emission in the fundamental z mode and second harmonic x mode become suppressed

  20. Cold leg injection reflood test results in the SCTF Core-I under constant system pressure

    International Nuclear Information System (INIS)

    Adachi, Hiromichi; Iwamura, Takamichi; Sobajima, Makoto; Osakabe, Masahiro; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio.

    1990-08-01

    The Slab Core Test Facility (SCTF) was constructed to investigate two-dimensional thermal-hydrodynamics in the core and the interaction in fluid behavior between the core and the upper plenum during the last part of blowdown, refill and reflood phases of a postulated loss-of-coolant accident (LOCA) of a pressurized water reactor (PWR). The present report describes the analytical results on the system behavior observed in the SCTF Core-I cold leg injection tests, S1-14 (Run 520), S1-15 (521), S1-16 (522), S1-17 (523), S1-20 (530), S1-21 (531), S1-23 (536) and S1-24 (537), performed under constant system pressure condition during transient. Major discussion items are: (1) steam binding, (2) U-tube oscillations, (3) bypass of ECC water (4) core cooling behavior, (5) effect of vent valve and (6) other parameter effects. These results give us very useful information and suggestion on reflood behavior. (author)

  1. ATHLET validation using accident management experiments

    Energy Technology Data Exchange (ETDEWEB)

    Teschendorff, V.; Glaeser, H.; Steinhoff, F. [Gasellschaft fuer Anlagen - und Reaktorsicherheit (GSR) mbH, Garching (Germany)

    1995-09-01

    The computer code ATHLET is being developed as an advanced best-estimate code for the simulation of leaks and transients in PWRs and BWRs including beyond design basis accidents. The code has features that are of special interest for applications to small leaks and transients with accident management, e.g. initialisation by a steady-state calculation, full-range drift-flux model, and dynamic mixture level tracking. The General Control Simulation Module of ATHLET is a flexible tool for the simulation of the balance-of-plant and control systems including the various operator actions in the course of accident sequences with AM measures. The systematic validation of ATHLET is based on a well balanced set of integral and separate effect tests derived from the CSNI proposal emphasising, however, the German combined ECC injection system which was investigated in the UPTF, PKL and LOBI test facilities. PKL-III test B 2.1 simulates a cool-down procedure during an emergency power case with three steam generators isolated. Natural circulation under these conditions was investigated in detail in a pressure range of 4 to 2 MPa. The transient was calculated over 22000 s with complicated boundary conditions including manual control actions. The calculations demonstrations the capability to model the following processes successfully: (1) variation of the natural circulation caused by steam generator isolation, (2) vapour formation in the U-tubes of the isolated steam generators, (3) break-down of circulation in the loop containing the isolated steam generator following controlled cool-down of the secondary side, (4) accumulation of vapour in the pressure vessel dome. One conclusion with respect to the suitability of experiments simulating AM procedures for code validation purposes is that complete documentation of control actions during the experiment must be available. Special attention should be given to the documentation of operator actions in the course of the experiment.

  2. Cold leg condensation tests. Task C. Steam--water interaction tests

    International Nuclear Information System (INIS)

    Brodrick, J.R.; Loiselle, V.

    1974-03-01

    A report is presented of tests to determine the condensation efficiency of ECC water injected into a quality fluid mixture flowing through the cold leg. In particular, a specific objective was to determine if the mixture of ECC water and quality fluid reached thermodynamic equilibrium before exiting the cold leg. Further, the stability of the ECC water/quality fluid interaction would be assessed by interpretation of thermocouple records and utilization of a section of cold leg piping with view ports to film the interaction whenever possible. The cold leg condensation tests showed complete condensation of the 5 lbm/sec steam quality mixtures in the cold leg by the ECC water flows of the test matrix. The cold leg exit fluid temperature remained below the saturation temperature and had good agreement with the predicted cold leg outlet temperature, calculated assuming total condensation. (U.S.)

  3. Recent results from the HIT-II and HIT-SI helicity injection current drive experiments

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Hamp, W.T.; Izzo, V.A.; Nelson, B.A.; O'Neill, R.G.; Raman, R.; Redd, A.J.; Sieck, P.E.; Smith, R.J.

    2005-01-01

    Three important results are reported. 1) CHI startup has produced 100 kA of closed current without using poloidal field (PF) coils or any transformer action. The initial equilibrium is then driven to 240 kA with a 3 V transformer loop voltage, indicating high quality plasma. 2) For the first time CHI alone has produced toroidal currents (350 kA) that far exceed q a I inj , and with I p /I tf as high as 1.2. The key to these new results appears to be having the toroidal field small enough that relaxation will occur. 3) The steady inductive helicity injection spheromak experiment has operated at 5 kHz for 6 ms with current amplitudes up to 11 kA in each injector. The helicity injection rate is nearly constant with the ExB flow always into the plasma and not into the walls. NIMROD simulations of HIT-SI show a buildup of spheromak fields. (author)

  4. Injection laryngoplasty using BIOPEX calcium phosphate cement. The Sanokousei General Hospital experience

    International Nuclear Information System (INIS)

    Okubo, Keisuke; Shinnabe, Akihiro; Saito, Koichiro; Shiotani, Akihiro

    2008-01-01

    The calcium phosphate bone paste BIOPEX is an injectable material developed as a bone replacement that hardens into a hydroxylapatite block after injection. BIOPEX offers many advantages as a material for injection laryngoplasty: it induces little foreign-material reaction, is minimally absorbed, and is easy to prepare in the OR. Between 2004 and 2007, 14 patients, including 13 with vocal fold paralysis and 1 with severe atrophy of the vocal folds, were treated with BIOPEX-injection laryngoplasty at Sanokousei General Hospital. The injection of BIOPEX is usually performed through a direct laryngoscopy under general anesthesia, and no adverse effects were observed in any of the cases. A postoperative three-dimensional CT revealed successful injection of the BIOPEX into the paraglottic space in all cases. BIOPEX is minimally absorbed over long time periods, and this procedure results in a dramatic improvement of glottic function immediately after surgery. We consider this operative technique, which aims at medialization of the vocal fold by injection of a sclerotic agent into the lateral side of the vocal fold, as 'type I thyroplasty from inside the laryngeal framework.' (author)

  5. Analysis of LOFT (L1-2) experiment by code RELAP-4J

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Soda, Kunihisa; Shiba, Masayoshi; Kaminaga, Humito

    1977-04-01

    An analysis of the results in LOFT L1-2 LOCE (Loss of Coolant Experiment) was made by the computer code RELAP-4J. The L1-2 experiment is a simple isothermal blowdown test with a core simulator and no ECC activation. It provides the basis for future LOCE with a nuclear core and ECC activation. The results of the analysis lead to the following conclusions. (1) The calculated system pressure transient agrees well with experiment. Primary controlling factors for the calculation are (a) flow resistances of the steam generator simulator, pump simulator and discharge nozzle in the broken loop, (b) mixture level in the downcomer and inlet volume of the operating loop steam generator, and (c) stored heat of the downcomer structure. (2) The pressurizer pressure decreases rapidly, compared with experiment, possibly because the flow resistance in the surge line is smaller than the actual one. Further experiment and analysis are necessary in this respect. (3) The calculated density transient in the cold leg agrees well with experiment. Agreement is not good in the hot leg, however. The discrepancy is possibly caused by the non-homogeneous flow of coolant in the hot leg due to low flow rate. (4) Effect of the pump characteristics on analytical result is insignificant in the isothermal test. However, in the future nuclear test, the effect will be significant because of large steam generation in the core, so measurement of the pump characteristics and improvement of the pump model are necessary. (auth.)

  6. Estimated net value and uncertainty for automating ECCS switchover at PWRs

    International Nuclear Information System (INIS)

    Walsh, B.; Brideau, J.; Comes, L.; Darby, J.; Guttmann, H.; Sciacca, F.; Souto, F.; Thomas, W.; Zigler, G.

    1996-02-01

    Question for resolution of Generic Safety Issue No. 24 is whether or not PWRs that currently rely on a manual system for ECCS switchover to recirculation should be required to install an automatic system. Risk estimates are obtained by reevaluating the contributions to core damage frequencies (CDFs) associated with failures of manual and semiautomatic switchover at a representative PWR. This study considers each separate instruction of the corresponding emergency operating procedures (EOPs), the mechanism for each control, and the relation of each control to its neighbors. Important contributions to CDF include human errors that result in completely coupled failure of both trains and failure to enter the required EOP. It is found that changeover to a semiautomatic system is not justified on the basis of cost-benefit analysis: going from a manual to a semiautomatic system reduces the CDF by 1.7 x 10 -5 per reactor-year, but the probability that the net cost of the modification being less than $1, 000 per person-rem is about 20% without license renewal. Scoping analyses, using optimist assumptions, were performed for a changeover to a semiautomatic system with automatic actuation and to a fully automatic system; in these cases the probability of a net cost being less than $1,000/person-rem is about 50% without license renewal and over 95% with license renewal

  7. The effect of blood injection for the prevention of Ethanol reflux after intrahepatic Ethanol injection in the rat

    International Nuclear Information System (INIS)

    Ahn, Kook Jin; Kim, Choon Yul; Kim, Bum Soo; Hahn, Seong Tai; Lee, Jae Mun; Shinn, Kyung Sub

    1998-01-01

    To reduce ethanol reflux from the needle channel by injecting rat blood immediately after the injection of ethanol into rat liver. The first experiment involved 33 rat livers which were divided into four groups (three livers in group 1;ten in groups 2, 3, and 4). Group 1 animals were used as controls, and 0.1ml saline was injected into the liver; in group 2, ethanol-Tc-99m-O 4 - mixed solution (0.1ml, 0.2mCi) was injected into the liver;in groups 3 and 4, the needle channel was blocked with 0.02ml of fresh blood and old blood, respectively, after the injection of ethanol. After removing the needle, a 3cm round filter paper was laid on each injection site to absorb refluxed ethanol-T c -99m-O 4 - mixed solution from the liver, and each paper was then counted by a gamma camera unit. In the second experiment, 33rats were divided into four groups (three rats in group 1;ten in groups 2, 3, and 4). Group 1 animals were used as controls, and after exposing the left lateral lobe of the liver, 0.05 ml of saline was injected;in group 2, 0.05 ml of ethanol was injected into the livder;in groups 3 and 4 the needle channel was blocked with 0.02 ml of fresh blood and old blood, respectively, after the injection of ethanol. After ten days, peritoneal adhesions were scored macroscopically and microscopically. In the first experiment using ethanol- T c -99m-O 4 - mixed solution, groups blocked with blood after the injection of mixed solution showed lower gamma counts than the group injected with mixed solution only (p-value=3D0.0002). The group blocked with old blood showed the lowest count. Macroscopical and microscopical examination of peritoneal adhesions indicated that the grade of adhesion was lower in groups blocked with blood than in the group injected with ethanol onluy (p-value=3D0.0261 and 0.0163, respectively). The above results suggest that an injection of blood after an injection of ethanol is a very effective way of preventing reflux from the liver.=20

  8. Natural gas extraction and artificial gas injection experiments in Opalinus Clay, Mont Terri rock laboratory (Switzerland)

    Energy Technology Data Exchange (ETDEWEB)

    Vinsot, A.; Lundy, M. [Agence Nationale pour la Gestion des Déchets Radioactifs ANDRA, Meuse Haute-Marne Center, Bure (France); Appelo, C.A.J. [Dr C.A.J. Appelo, Hydrochemical Consultant, Amsterdam (Netherlands); and others

    2017-04-15

    Two experiments have been installed at Mont Terri in 2004 and 2009 that allowed gas circulation within a borehole at a pressure between 1 and 2 bar. These experiments made it possible to observe the natural gases that were initially dissolved in pore-water degassing into the borehole and to monitor their content evolution in the borehole over several years. They also allowed for inert (He, Ne) and reactive (H{sub 2}) gases to be injected into the borehole with the aim either to determine their diffusion properties into the rock pore-water or to evaluate their removal reaction kinetics. The natural gases identified were CO{sub 2}, light alkanes, He, and more importantly N{sub 2}. The natural concentration of four gases in Opalinus Clay pore-water was evaluated at the experiment location: N{sub 2} 2.2 mmol/L ± 25%, CH{sub 4} 0.30 mmol/L ± 25%, C{sub 2}H{sub 6} 0.023 mmol/L ± 25%, C{sub 3}H{sub 8} 0.012 mmol/L ± 25%. Retention properties of methane, ethane, and propane were estimated. Ne injection tests helped to characterize rock diffusion properties regarding the dissolved inert gases. These experimental results are highly relevant towards evaluating how the fluid composition could possibly evolve in the drifts of a radioactive waste disposal facility. (authors)

  9. A three-dimensional laboratory steam injection model allowing in situ saturation measurements. [Comparing steam injection and steam foam injection with nitrogen and without nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Demiral, B.M.R.; Pettit, P.A.; Castanier, L.M.; Brigham, W.E.

    1992-08-01

    The CT imaging technique together with temperature and pressure measurements were used to follow the steam propagation during steam and steam foam injection experiments in a three dimensional laboratory steam injection model. The advantages and disadvantages of different geometries were examined to find out which could best represent radial and gravity override flows and also fit the dimensions of the scanning field of the CT scanner. During experiments, steam was injected continuously at a constant rate into the water saturated model and CT scans were taken at six different cross sections of the model. Pressure and temperature data were collected with time at three different levels in the model. During steam injection experiments, the saturations obtained by CT matched well with the temperature data. That is, the steam override as observed by temperature data was also clearly seen on the CT pictures. During the runs where foam was present, the saturation distributions obtained from CT pictures showed a piston like displacement. However, the temperature distributions were different depending on the type of steam foam process used. The results clearly show that the pressure/temperature data alone are not sufficient to study steam foam in the presence of non-condensible gas.

  10. Injection-induced moment release can also be aseismic

    Science.gov (United States)

    McGarr, Arthur; Barbour, Andrew J.

    2018-01-01

    The cumulative seismic moment is a robust measure of the earthquake response to fluid injection for injection volumes ranging from 3100 to about 12 million m3. Over this range, the moment release is limited to twice the product of the shear modulus and the volume of injected fluid. This relation also applies at the much smaller injection volumes of the field experiment in France reported by Guglielmi, et al. (2015) and laboratory experiments to simulate hydraulic fracturing described by Goodfellow, et al. (2015). In both of these studies, the relevant moment release for comparison with the fluid injection was aseismic and consistent with the scaling that applies to the much larger volumes associated with injection-induced earthquakes with magnitudes extending up to 5.8. Neither the micro-earthquakes, at the site in France, nor the acoustic emission in the laboratory samples contributed significantly to the deformation due to fluid injection.

  11. Experiment data of ROSA-III integral test RUN 710

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Tasaka, Kanji; Adachi, Hiromichi; Anoda, Yoshinari; Soda, Kunihisa

    1981-01-01

    The report presents data of RUN 710 at ROSA-III test facility. RUN 710 simulates a 200% double-ended break at the inlest side of a recirculation pump of a BWR. All ECCS are activated and electric power to simulated fuel rods in one core channel among four is not supplied in RUN 710. The primary initial conditions are steam dome pressure 7.35 MPa, lower plenum subcooling 10.8 K, core inlet flow rate 31.3 kg/s and core heat generation 2.42 MW. Peak cladding temperature is 609 K at Position 3, 352.5 mm above the mid plane of the core. All heater rods are quenched after ECCS actuation and the effectiveness of ECCS is confirmed. (author)

  12. Systematic evaluation program review of NRC Safety Topic VI-7.3 associated with the electrical, instrumentation and control portions of the ECCS actuation system for the Dresden II Nuclear Power Plant

    International Nuclear Information System (INIS)

    St Leger-Barter, G.

    1980-11-01

    This report documents the technical evaluation and review of NRC Safety Topic VI-7.A.3, associated with the electrical, instrumentation, and control portions of the classification of the ECCS actuation system for the Dresden II nuclear power plant, using current licensing criteria

  13. Animal experiment and clinical preliminary application of percutaneous 70% ethanol injection therapy in multi-drug resistant pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Liu Fuquan; Yue Zhendong; Gao Shunyu; Li YanSheng; Wei Guobin; Guo Weiyi; Chen Xijun; Li Baoyu

    2004-01-01

    Objective: To evaluate the clinical value of percutaneous injection of 70% ethanol in the treatment of multidrug resistant pulmonary tuberculosis. Methods: Percutaneous and transcatheter absolute ethanol, 70% ethanol, and 60% meglucamine diatrizoate(or distilled water) injection into the lung (25 cases) and the bronchi (25 cases) of healthy rabbits were performed, respectively.All specimens were studied with pathology. On the base of animals experiment, thirty-five patients with multi-drug resistant pulmonary tuberculosis were treated with percutaneous 70% ethanol injection. Every patient was treated by the same way for 1-3 times. Results: Pathological findings of the specimens of pulmonary tissue showed nonspecific inflammation, necrosis, and fibrosis. The chief pathological changes with percutaneous or transcatheter 70% ethanol injection were slighter than those with absolute ethanol injection. Pathological findings of the specimens of bronchi showed slight mucosal edema, nonspecific inflammation, and focal cytonecrosis. Recovery of the damaged bronchial mucosa occurred within 14-30 days after the treatment. All patients with multi-drug resistant pulmonary tuberculosis were followed up for 6 to 33 months. The sputum bacterial conversion to negative rate was 100% within 6 months after the treatment. Cavity closing, shrinking, and no changing rate were 47.1% (16/34), 50.0% (17/34), and 2.9% (1/34), respectively. Radiographic improvement rate was 94.3 % (33/35). No severe complications and adverse reactions occurred. Conclusion: Percutaneous 70% ethanol injection is safe, effective, and easy to perform in the treatment of multi-drug resistant pulmonary tuberculosis. (authors)

  14. Endoscopic treatment of vesicoureteral reflux in children with subureteral dextranomer/hyaluronic acid injection: a single-centre, 7-year experience

    Science.gov (United States)

    Biočíc, Mihovil; Todoríc, Jakov; Budimir, Dražen; Roíc, Andrea Cvitkovíc; Pogorelíc, Zenon; Juríc, Ivo; Šušnjar, Tomislav

    2012-01-01

    Background The goals of medical intervention in patients with vesicoureteral reflux are to allow normal renal growth, prevent infections and pyelonephritis, and prevent renal failure. We present our experience with endoscopic treatment of vesicoureteral reflux in children by subureteral dextranomer/hyaluronic acid copolymer injection. Methods Under cystoscopic guidance, dextranomer/hyaluronic acid copolymer underneath the intravesical portion of the ureter in a subureteral or submucosal location was injected in patients undergoing endoscopic correction of vesicoureteral reflux. Results A total of 282 patients (120 boys and 162 girls) underwent the procedure. There were 396 refluxed ureters altogether. The mean age of patients was 4.9 years. The mean overall follow-up period was 44 months. Among the 396 ureters treated, 76% were cured with a single injection. A second and third injection raised the cure rate to 93% and 94%, respectively. Twenty-two (6%) ureters failed all 3 injections, and were converted to open surgery. Conclusion Endoscopic treatment of vesicoureteral reflux can be recommended as a first-line therapy for most cases of vesicoureteral reflux, because of the short hospital stay, absence of complications and the high success rate. PMID:22854114

  15. Evaluation report on SCTF Core-III tests S3-7 and S3-8

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Iguchi, Tadashi; Iwamura, Takamichi

    1990-03-01

    It has been said that the Emergency Core Cooling (ECC) water injected into the hot legs flows into the upper plenum and then falls back to the core (i.e. break-through) during reflood phase in a German type Pressurized Water Reactor (GPWR) with the combined-injection-type ECCS, and that the break-through occurs where the water temperature at the tie plate area is lower and subcooled. Based on this information two tests were conducted with the Slab Core Test Facility (SCTF) Core-III in order to investigate the effects of the water temperature distribution at the tie plate area on the break-through and the core cooling. In these tests, the subcooled ECC water was injected just above the Upper Core Support Plate (UCSP) in order to establish the desired water temperature distribution at the tie plate area. In one test (Test S3-7) the ECC water injection above the UCSP was performed above Bundles 3 and 4, and in the other test (Test S3-8) above Bundles 7 and 8 during initial 60 s a and then was changed to above Bundles 3 and 4. The test data were compared with those of Test S3-SH1, in which the injection was performed above Bundles 7 and 8 and the other test conditions were the same as in Tests S3-7 and S3-8. Analyzing these test data, the following has been found: The break-through occurs where the water temperature at the tie plate area is subcooled and the core cooling is enhanced significantly in the break-through region. The break-through location changes, with some time lag, following the change of the water temperature distribution at the tie plate area. Furthermore, the core cooling in the non-break-through regions is almost the same regardless of the location of the break-through. (author)

  16. Exxon Nuclear WREM-based NJP-BWR ECCS evaluation model and example application to the Oyster Creek Plant

    International Nuclear Information System (INIS)

    Krysinski, T.L.; Bjornard, T.A.; Steves, L.H.

    1975-01-01

    A proposed integrated ECCS model for non-jet pump boiling water reactors is presented, using the RELAP4-EM/BLOWDOWN and RELAP4-EM/SMALL BREAK portions of the Exxon Nuclear WREM-based Generic PWR Evaluation Model coupled with the ENC NJP-BWR Fuel Heatup Model. The results of the application of the proposed model to Oyster Creek are summarized. The results of the break size sensitivity study using the proposed model for the Oyster Creek Plant are presented. The application of the above results yielded the MAPLHGR curves. Included are a description of the proposed non-jet pump boiling water reaction evaluation model, justification of its conformance with TOCFR50, Appendix K, the adopted Oyster Creek plant model, and results of the analysis and sensitivity studies. (auth)

  17. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    Science.gov (United States)

    Mehmood, Zahid; Chen, Gongliang; Li, Jianhua; Li, Linsen; Alzahrani, Bander

    2017-01-01

    Over the past few years, Session Initiation Protocol (SIP) is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  18. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    Directory of Open Access Journals (Sweden)

    Zahid Mehmood

    Full Text Available Over the past few years, Session Initiation Protocol (SIP is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  19. Survey of Botulinum Toxin Injections in Anticoagulated Patients: Korean Physiatrists' Preference in Controlling Anticoagulation Profile Prior to Intramuscular Injection.

    Science.gov (United States)

    Jang, Yongjun; Park, Geun-Young; Park, Jihye; Choi, Asayeon; Kim, Soo Yeon; Boulias, Chris; Phadke, Chetan P; Ismail, Farooq; Im, Sun

    2016-04-01

    To evaluate Korean physiatrists' practice of performing intramuscular botulinum toxin injection in anticoagulated patients and to assess their preference in controlling the bleeding risk before injection. As part of an international collaboration survey study, a questionnaire survey was administered to 100 Korean physiatrists. Physiatrists were asked about their level of experience with botulinum toxin injection, the safe international normalized ratio range in anticoagulated patients undergoing injection, their tendency for injecting into deep muscles, and their experience of bleeding complications. International normalized ratio injection by 41% of the respondents. Thirty-six respondents replied that the international normalized ratio should be lowered to sub-therapeutic levels before injection, and 18% of the respondents reported that anticoagulants should be intentionally withheld and discontinued prior to injection. In addition, 20%-30% of the respondents answered that they were uncertain whether they should perform the injection regardless of the international normalized ratio values. About 69% of the respondents replied that they did have any standardized protocols for performing botulinum toxin injection in patients using anticoagulants. Only 1 physiatrist replied that he had encountered a case of compartment syndrome. In accordance with the lack of consensus in performing intramuscular botulinum toxin injection in anticoagulated patients, our survey shows a wide range of practices among many Korean physiatrists; they tend to avoid botulinum toxin injection in anticoagulated patients and are uncertain about how to approach these patients. The results of this study emphasize the need for formulating a proper international consensus on botulinum toxin injection management in anticoagulated patients.

  20. An analysis of the SCEX 3 ionospheric electron beam injection experiment

    International Nuclear Information System (INIS)

    Goerke, R.T.

    1992-01-01

    The SCEX 3 experiment (Several Compatible EXperiments using a rocket-borne accelerator) was carried to ionospheric altitudes (375 km) by a Black Brant 11 rocket on February 1, 1990. The experiment was launched from Poker Flat Research Range (65.1 degree N, 147.5 degree W) at 1207 UT. The payload split into two parts (hereafter forward and aft payloads) 116 seconds after launch. The aft payload carried two electron accelerators as well as several diagnostic instruments. The forward payload was ejected at an angle of 6 degree with the magnetic field in a northwesterly direction. This payload carried a multiband plasma wave receiver and various particle detectors to make in situ measurements of the Beam Plasma Interaction (BPI) region. Two Throw Away Detectors (TAD's 1 and 2) were also ejected from the aft payload in the east and west directions respectively. TAD 1 also carried a multiband plasma wave receiver. Preceding the launch an auroral arch along the southern boundary of a diffuse auroral patch suddenly brightened, split into two separate arcs and moved to a position north of the rocket's trajectory. SCEX 3 was launched into an active breakup aurora consisting of tall rays and diffuse patches. The purpose of this experiment were (1) to observe injected electrons reflected from the naturally occurring parallel electric field structures which are thought to accelerate the auroral electron, (2) to observe a variety of plasma effects caused by the artificial electron beam and the associated spacecraft charging, and (3) study the natural phenomena associated with auroral activity. This work is a summary of the interesting observations made by the SCEX 3 experiment. These observations include VHF emissions produced by the electron beam via the Beam Plasma Discharge (BPD), Diffuse resonance emissions by the hot plasma region surrounding the electron beam and auroral Z-mode emissions

  1. H- charge exchange injection systems

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Curtis, C.; Hojvat, C.; Johnson, R.P.; Owen, C.; Schmidt, C.; Teng, L.; Webber, R.C.

    1980-01-01

    The techniques and components required for injection of protons into cyclic accelerators by means of H - charge exchange processes are reviewed, with emphasis on the experience at Fermilab. The advantages of the technique are described. The design and performance of the system of injection of H - ions into the Fermilab Booster are detailed. (Auth.)

  2. Study of the effects induced by lead on the emulsion films of the OPERA experiment

    CERN Document Server

    Anokhina, A.; Ariga, A.; Arrabito, L.; Autiero, D.; Badertscher, A.; Bay, F.; Bergnoli, A.; Bersani Greggio, F.; Besnier, M.; Bick, D.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Carrara, E.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Consiglio, L.; Cozzi, M.; Dal Corso, F.; D'Amato, G.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Di Troia, C.; Dmitrievski, S.; Dominjon, A.; Dracos, M.; Duchesneau, D.; Dulach, B.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, A.; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Franceschi, A.; Fukuda, T.; Fukushima, C.; Galkin, V.I.; Galkin, V.A.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Golubkov, D.; Gornoushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gusev, G.; Gustavino, C.; Hagner, Caren; Hara, T.; Hierholzer, M.; Hiramatsu, S.; Hoshino, Kaoru; Ieva, M.; Jakovcic, K.; Janicsko Csathy, J.; Janutta, B.; Jollet, C.; Juget, F.; Kawai, T.; Kazuyama, M.; Kim, S.H.; Kimura, M.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laktineh, I.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, Andrea; Lutter, G.; Manai, K.; Mandrioli, G.; Manzoor, S.; Marotta, A.; Marteau, J.; Matsuoka, H.; Mauri, N.; Meisel, F.; Meregaglia, A.; Messina, M.; Migliozzi, P.; Miyamoto, S.; Monacelli, P.; Morishima, K.; Moser, U.; Muciaccia, M.T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakamura, T.; Nakano, T.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Osedlo, V.; Ossetski, D.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pistillo, C.; Polukhina, N.; Pozzato, M.; Pretzl, K.; Publichenko, P.; Pupilli, F.; Roganova, T.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryazhskaya, O.; Ryzhikov, D.; Sato, Y.; Sato, O.; Saveliev, V.; Sazhina, G.; Schembri, A.; Scotto Lavina, L.; Shibuya, H.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, Paolo Emilio; Sugonyaev, V.; Taira, Y.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Togo, V.; Tolun, P.; Tsarev, V.; Tufanli, S.; Ushida, N.; Valieri, C.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Wurtz, J.; Yoon, C.S.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, A.; Zimmermann, R.

    2008-01-01

    The OPERA neutrino oscillation experiment is based on the use of the Emulsion Cloud Chamber (ECC). In the OPERA ECC, nuclear emulsion films acting as very high precision tracking detectors are interleaved with lead plates providing a massive target for neutrino interactions. We report on studies related to the effects occurring from the contact between emulsion and lead. A low radioactivity lead is required in order to minimize the number of background tracks in emulsions and to achieve the required performance in the reconstruction of neutrino events. It was observed that adding other chemical elements to the lead, in order to improve the mechanical properties, may significantly increase the level of radioactivity on the emulsions. A detailed study was made in order to choose a lead alloy with good mechanical properties and an appropriate packing technique so as to have a low enough effective radioactivity.

  3. Evaluation of the long duration efficiency of the ECC storage facility of Cogema La Hague plant

    International Nuclear Information System (INIS)

    Baganz, C.; Bouland, P.; Breton, E.

    2004-01-01

    The ECC facility of Cogema La Hague has been designed in view of the storage of 24000 CSD-C type containers produced by the ACC facility. It comprises a reception and unloading unit, and a modular storage unit (alveoles). The safety of the facility is based on: a controlled ventilation (low pressurization rooms, controlled atmosphere, heat and toxic gases evacuation), a construction ensuring the static confinement, the sub-criticality and the radiological protection, and the possibility of natural ventilation of the alveoles (earthquake-dimensioned equipments). On the basis of these safety functions, the conformability of the facility with respect to long duration has been analyzed considering three aspects of the facility: the infrastructure, the waste packages and the ventilation system. In normal operation, a foreseeable service life of at least 100 years is established: simpleness and accessibility of ventilation systems, no significant corrosion of packages, durability of the reinforced concrete structure. The demonstration of a service life greater than 100 years would require the improvement of our knowledge about concretes in terms of experience feedback. The behaviour of the facility in terms of loss of technical mastery has been considered too. The scenario retained for this situation is the prolonged stoppage (several months or years) of the nuclear ventilation after a 100 years of disposal. After this period of time, both the thermal power and the hydrogen generation from waste packages will have significantly diminished, allowing a loss of technical mastery era of several years with no impact on concretes integrity. However, during long situations of non-controlled atmosphere, the corrosion behaviour of stainless steels is not predictable. (J.S.)

  4. Role of calpain in eccentric contraction-induced proteolysis of Ca2+-regulatory proteins and force depression in rat fast-twitch skeletal muscle.

    Science.gov (United States)

    Kanzaki, Keita; Watanabe, Daiki; Kuratani, Mai; Yamada, Takashi; Matsunaga, Satoshi; Wada, Masanobu

    2017-02-01

    The aim of this study was to examine the in vivo effects of eccentric contraction (ECC) on calpain-dependent proteolysis of Ca 2+ -regulatory proteins and force production in fast-twitch skeletal muscles. Rat extensor digitorum longus muscles were exposed to 200 repeated ECC in situ and excised immediately [recovery 0 (REC0)] or 3 days [recovery 3 (REC3)] after cessation of ECC. Calpain inhibitor (CI)-treated rats were intraperitoneally injected with MDL-28170 before ECC and during REC3. Tetanic force was markedly reduced at REC0 and remained reduced at REC3. CI treatment ameliorated the ECC-induced force decline but only at REC3. No evidence was found for proteolysis of dihydropyridine receptor (DHPR), junctophilin (JP)1, JP2, ryanodine receptor (RyR), sarcoplasmic reticulum Ca 2+ -ATPase (SERCA)1a, or junctional face protein-45 at REC0. At REC3, ECC resulted in decreases in DHPR, JP1, JP2, RyR, and SERCA1a. CI treatment prevented the decreases in DHPR, JP1, and JP2, whereas it had little effect on RyR and SERCA1a. These findings suggest that DHPR, JP1, and JP2, but not RyR and SERCA1a, undergo calpain-dependent proteolysis in in vivo muscles subjected to ECC and that impaired function of DHPR and/or JP might cause prolonged force deficits with ECC. NEW & NOTEWORTHY Calpain-dependent proteolysis is one of the contributing factors to muscle damage that occurs with eccentric contraction (ECC). It is unclear, however, whether calpains account for proteolysis of Ca 2+ -regulatory proteins in in vivo muscles subjected to ECC. Here, we provide evidence that dihydropyridine receptor and junctophilin, but not ryanodine receptor and sarcoplasmic reticulum Ca 2+ -ATPase, undergo calpain-dependent proteolysis. Copyright © 2017 the American Physiological Society.

  5. Post-test analysis of ROSA-III experiment RUNs 705 and 706

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Soda, Kunihisa; Kikuchi, Osamu; Tasaka, Kanji; Shiba, Masayoshi

    1980-07-01

    The purpose of ROSA-III experiment with a scaled BWR Test facility is to examine primary coolant thermal-hydraulic behavior and performance of ECCS during a postulated loss-of-coolant accident of BWR. The results provide the information for verification and improvement of reactor safety analysis codes. RUNs 705 and 706 assumed a 200% double-ended break at the recirculation pump suction. RUN 705 was an isothermal blowdown test without initial power and initial core flow. In RUN 706 for an average core power and no ECCS, the main steam line and feed water line were isolated immediately on the break. Post-test analysis of RUNs 705 and 706 was made with computer code RELAP4J. The agreement in system pressure between calculation and experiment was satisfactory. However, the calculated heater rod surface temperature were significantly higher than the experimental ones. The calculated axial temperature profile was different in tendency from the experimental one. The calculated mixture level behavior in the core was different from the liquid void distribution observed in experiment. The rapid rise of fuel rod surface temperature was caused by the reduction of heat transfer coefficient attributed to the increase of quality. The need was indicated for improvement of analytical model of void distribution in the core, and also to performe a characteristic test of recirculation line under reverse flow and to examine the core inlet flow rate experimentally and analytically. (author)

  6. Multilevel Botulinum Toxin A (Abobotulinum Toxin A Injections in Spastic Forms of Cerebral Palsy: Retrospective Analysis of 8 Russian Centers Experience

    Directory of Open Access Journals (Sweden)

    O. A. Klochkova

    2016-01-01

    Full Text Available Background: The contemporary application of Botulinum toxin A (BTA in cerebral palsy (CP implies multilevel injections both in on-label and off-label muscles. However, there is no single international opinion on the effective and safe dosages, target muscles, and intervals between the injections.Objective: Our aim was to analyze the Russian multicenter independent experience of single and repeated multilevel injections of Abobotulinum toxin А in patients with spastic forms of CP.Methods: 8 independent referral CP-centers (10 hospitals in different regions of Russia. Authors evaluated intervals between the injections, dosages of the BTA for the whole procedure, for the body mass, for the each muscle, and functional segment of the extremities.Results: 1872 protocols of effective BTA injections (1–14 repeated injections for 724 patients with spastic CP were included. The age of the patients was between 8 months to 17 years 4 months at the beginning of the treatment (with a mean of 3 years 10 months. Multilevel BTA injections were indicated for the majority (n = 634, 87.6% of the patients in all the centers. The medians of the dosages for the first BTA injection were between 30–31 U/kg (500 U, the repeated injections doses up to 45 U/kg (1000 U (in most centers. The median intervals between the repeated injections were 180–200 days in 484 (66.9% patients and 140–180 days in 157 (24.7% patients. In 2 centers, children with GMFCS IV–V were injected more often than others.Conclusion: Multilevel BTA injections were indicated for the most patients. The initial dose of Abobotulinum toxin A was 30–31 U/kg. The repeated injections dose could increase up to 40 U/kg. The repeated injections were done in 140–200 days after the previous injection.

  7. UPTF test 21D counterpart test in the MIDAS test facility

    International Nuclear Information System (INIS)

    Yoon, B. C.; Ah, D. J.; Joo, I. C.; Kwon, T. S.; Park, W. M.; Song, C. H.

    2002-01-01

    This paper describes the experimental results of UPTF Test 21D counterpart tests in the downcomer during the late reflood phase of LBLOCA. The experiments have been performed in the MIDAS test facility using superheated steam and water. The test condition was determined,based on the test results of UPTF Test 21D, by applying the 'modified linear scaling method of 1/4.077 length scale. The tests of ECC direct bypass and void height are performed separately to estimate each phenomena quantitatively. The tests were carried out by varying the injection steam flow rate of intact cold legs widely to investigate the effect of steam flow rate on the direct bypass fraction and void height. In the tests, separate effect tests have been performed in cases of DVI-1,DVI- 2 and DVI-1 and 2 injections to see the direct bypass fraction according to the DVI nozzle combination. From the tests, we found that the fraction of direct ECC bypass and the void height observed in the MIDAS test facility reasonably well agree with those of UPTF test 21- D. It confirms that the applied 'modified linear scaling law' reproduces major thermal hydraulics phenomena in the downcomer during the LBLOCA reflood phase

  8. Overdose experiences among injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Wood Evan

    2010-05-01

    Full Text Available Abstract Background Although previous studies have identified high levels of drug-related harm in Thailand, little is known about illicit drug overdose experiences among Thai drug users. We sought to investigate non-fatal overdose experiences and responses to overdose among a community-recruited sample of injection drug users (IDU in Bangkok, Thailand. Methods Data for these analyses came from IDU participating in the Mit Sampan Community Research Project. The primary outcome of interest was a self-reported history of non-fatal overdose. We calculated the prevalence of past overdose and estimated its relationship with individual, drug-using, social, and structural factors using multivariate logistic regression. We also assessed the prevalence of ever witnessing an overdose and patterns of response to overdose. Results These analyses included 252 individuals; their median age was 36.5 years (IQR: 29.0 - 44.0 and 66 (26.2% were female. A history of non-fatal overdose was reported by 75 (29.8% participants. In a multivariate model, reporting a history of overdose was independently associated with a history of incarceration (Adjusted Odds Ratio [AOR] = 3.83, 95% Confidence Interval [CI]: 1.52 - 9.65, p = 0.004 and reporting use of drugs in combination (AOR = 2.48, 95% CI: 1.16 - 5.33, p = 0.019. A majority (67.9% reported a history of witnessing an overdose; most reported responding to the most recent overdose using first aid (79.5%. Conclusions Experiencing and witnessing an overdose were common in this sample of Thai IDU. These findings support the need for increased provision of evidence-based responses to overdose including peer-based overdose interventions.

  9. Verification of LOCA/ECCS analysis codes ALARM-B2 and THYDE-B1 by comparison with RELAP4/MOD6/U4/J3

    International Nuclear Information System (INIS)

    Shimizu, Takashi

    1982-08-01

    For a verification study of ALARM-B2 code and THYDE-B1 code which are the component of the JAERI code system for evaluation of BWR ECCS performance, calculations for typical small and large break LOCA in BWR were done, and compared with those by RELAP4/MOD6/U4/J3 code. This report describes the influences of differences between the analytical models incorporated in the individual code and the problems identified by this verification study. (author)

  10. Progestogen-only injectable contraceptive: Experience of women in ...

    African Journals Online (AJOL)

    Background: Progestogen-only injectable contraceptive is a long-acting contraceptive given intramuscularly to give protection against unwanted pregnancy for a period of 2 or 3 months, depending on the type. Alterations in menstrual pattern are a well known side effect of this effective contraceptive method. Objectives: To ...

  11. CO2 injection into fractured peridotites: a reactive percolation experiment

    Science.gov (United States)

    Escario, S.; Godard, M.; Gouze, P.; Leprovost, R.; Luquot, L.; Garcia-Rios, M.

    2017-12-01

    Mantle peridotites have the potential to trap CO2 as carbonates. This process observed in ophiolites and in oceanic environments provides a long term and safe storage for CO2. It occurs as a part of a complex suite of fluid-rock reactions involving silicate dissolution and precipitation of hydrous phases, carbonates and minor phases that may in turn modify the hydrodynamic properties and the reactivity of the reacted rocks. The efficiency and lastingness of the process require the renewal of fluids at the mineral-fluid interface. Fractures are dominant flow paths in exhumed mantle sections. This study aims at better understanding the effect of CO2-enriched saline fluids on hydrodynamic and chemical processes through fractured peridotites. Experiments were performed using the reactive percolation bench ICARE Lab 3 - Géosciences Montpellier. It allows monitoring the permeability changes during experiments. Effluents are recurrently sampled for analysing cation concentration, pH and alkalinity. Reacted rock samples were characterized by high resolution X-ray microtomography (ESRF ID19, Grenoble, France) and SEM. Experiments consisted in injecting CO2-enriched brines (NaCl 0.5 M) at a rate of 6 mL.h-1 into artificially fractured cores (9 mm diameter × 20 mm length) of Oman harzburgites at T=170°C and Ptotal = 25 MPa for up to 2 weeks. Fractures are of few µm apertures with rough walls. Three sets of experiments were performed at increasing value of [CO2] (0, 0.1 and 1 mol/kg). All experiments showed a decrease in permeability followed by steady state regime that can be caused by a decrease in the roughness of fracture walls (dissolution dominated process), thus favouring fracture closing, or by the precipitation of secondary phases. Maximum enrichments in Mg, Fe and Ca of the effluent fluids occur during the first 2 hours of the experiments whereas Si displays a maximum enrichment at t = 20 h, suggesting extensive dissolution. Maximum enrichments are observed with

  12. Large scale injection test (LASGIT) modelling

    International Nuclear Information System (INIS)

    Arnedo, D.; Olivella, S.; Alonso, E.E.

    2010-01-01

    Document available in extended abstract form only. With the objective of understanding the gas flow processes through clay barriers in schemes of radioactive waste disposal, the Lasgit in situ experiment was planned and is currently in progress. The modelling of the experiment will permit to better understand of the responses, to confirm hypothesis of mechanisms and processes and to learn in order to design future experiments. The experiment and modelling activities are included in the project FORGE (FP7). The in situ large scale injection test Lasgit is currently being performed at the Aespoe Hard Rock Laboratory by SKB and BGS. An schematic layout of the test is shown. The deposition hole follows the KBS3 scheme. A copper canister is installed in the axe of the deposition hole, surrounded by blocks of highly compacted MX-80 bentonite. A concrete plug is placed at the top of the buffer. A metallic lid anchored to the surrounding host rock is included in order to prevent vertical movements of the whole system during gas injection stages (high gas injection pressures are expected to be reached). Hydration of the buffer material is achieved by injecting water through filter mats, two placed at the rock walls and two at the interfaces between bentonite blocks. Water is also injected through the 12 canister filters. Gas injection stages are performed injecting gas to some of the canister injection filters. Since the water pressure and the stresses (swelling pressure development) will be high during gas injection, it is necessary to inject at high gas pressures. This implies mechanical couplings as gas penetrates after the gas entry pressure is achieved and may produce deformations which in turn lead to permeability increments. A 3D hydro-mechanical numerical model of the test using CODE-BRIGHT is presented. The domain considered for the modelling is shown. The materials considered in the simulation are the MX-80 bentonite blocks (cylinders and rings), the concrete plug

  13. Tokamak experiments on JIPP T-II with pulsed gas injection

    International Nuclear Information System (INIS)

    Toi, K.; Itoh, S.; Fujita, J.; Kadota, K.; Kawahata, K.

    1978-02-01

    The confinement of tokamak plasma has been investigated in the wide range of electron density average n sub(e) from 1 x 10 13 to 5 x 10 13 cm -3 by using the pulsed gas injection. The gross energy confinement time increases with increase of electron density and reaches 14 msec. The averaged effective ionic charge derived from plasma conductivity = is about 1 to 2 in the regime of small streaming parameter ( = 0.01 -- 0.08). The ratio of ion temperature to electron one is in the range greater than 0.5. This fact means that the ion energy confinement time is greater than the electron-ion energy relaxation time. Excessive injection of cold neutral gas excites m = 2 MHD oscillations. Much more gas injection leads to the remarkable cooling of plasma periphery and disruptive instabilities. These MHD oscillations and disruptive instabilities have been suppressed by the heating of plasma periphery with the second rapid rise of plasma current. (auth.)

  14. Secondary and tertiary gas injection in fractured carbonate rock: Experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Karimaie, H.; Torsaeter, O. [SPE, NTNU (Norway); Darvish, G.R. [SPE, STATOIL (Norway); Lindeberg, E. [SPE, SINTEF (Norway)

    2008-09-15

    The use of CO{sub 2} has received considerable interest as a method of EOR but a major drawback is its availability and increasing cost. Therefore, as the number of CO{sub 2} injection projects increase, an alternative must be considered to meet the economic considerations. For this reason attention has been directed to nitrogen injection which may be a good substitute for CO{sub 2}. The purpose of the experiments described in this paper was to investigate the efficiency of oil recovery by CO{sub 2} and N{sub 2} in fractured carbonate rock. The combined effects of gravity drainage and component exchange between gas in fracture and oil in matrix on oil recovery in fractured reservoirs subjected to CO{sub 2} or nitrogen gas injection are experimentally studied. Laboratory experiments have been carried out on a low permeable outcrop chalk, as an analogue to a North Sea reservoir rock. This was surrounded by a fracture, established with a novel experimental set-up. The experiments aimed to investigate the potential of oil recovery by secondary and tertiary CO{sub 2} and nitrogen gas injection at high pressure high temperature condition. The matrix block was saturated using recombined binary mixture live oil (C{sub 1}-C{sub 7}), while the fracture was filled with a sealing material to obtain a homogeneous saturation. The sealing material was then removed by increasing the temperature which in turn creates the fracture surrounding the core. Gas was injected into the fracture at pressures above the bubble point of the oil. Oil recovery as a function of time was monitored during the experiments. Results from secondary gas injection experiments indicate that CO{sub 2} injection at elevated pressure and temperature is more efficient than N{sub 2} injection. Results from tertiary gas injection experiments also show that injection of CO{sub 2} could significantly recover the oil, even after waterflooding, compared to N{sub 2} injection. (author)

  15. CATHENA simulations of steam generator tube rupture

    International Nuclear Information System (INIS)

    Abdul-Razzak, A.; Lin, M.R.; Wright, A.C.D.

    1997-01-01

    The CATHENA thermalhydraulic computer code was used to simulate various scenarios following a CANDU 9 steam generator tube rupture (SGTR) event. The analysis included cases with class IV power and emergency core cooling system (ECCS) available and other cases with subsequent loss of class IV power (LCIVP) or impairment of ECCS injection. Two main approaches were followed in the analysis of each case. In the first approach, D 2 O feed was credited to provide conservative data for input to radionuclide release and dose calculations. Also operator actions are credited. The other approach is designed to give conservative predictions with respect to the acceptance criteria of fuel and fuel channel integrity and to prove that in case of such event, the operator will have enough time to mitigate the consequences. This is done by not crediting makeup for the inventory loss and relying on the automatic operation of safety systems. The analysis of the cases of the first approach provided the required data for radionuclide release and dose calculations and gave a good insight into the required sequence of operator timely actions to mitigate the consequences of such event. On the other hand, the cases of the second approach confirmed compliance with regulatory requirements for pressure tube and fuel integrity. The runs with ECCS available, showed the ECCS injection is effective in filling and cooling the core and that regulatory requirement's for fuel and channel integrity are met. In the event of ECCS impairment, the earliest indication of late fuel heat-up is late enough to provide the operator with an adequate time to act in mitigating the consequences of this event. (author)

  16. An anaerobic field injection experiment in a landfill leachate plume (Grindsted, Denmark)

    DEFF Research Database (Denmark)

    Albrechtsen, Hans-Jørgen; Bjerg, Poul Løgstrup; Ludvigsen, L.

    1999-01-01

    Redox conditions may be environmental factors which affect the fate of the xenobiotic organic compounds. Therefore the redox conditions were characterized in an anaerobic, leachate-contaminated aquifer 15–60 m downgradient from the Grindsted Landfill, Denmark, where an field injection experiment...... was carried out. Furthermore, the stability of the redox conditions spatially and over time were investigated, and different approaches to deduce the redox conditions were evaluated. The redox conditions were evaluated in a set of 20 sediment and groundwater samples taken from locations adjacent...... to the sediment samples. Samples were investigated with respect to groundwater chemistry, including hydrogen and volatile fatty acids (VFAs) and sediment geochemistry, and bioassays were performed. The groundwater chemistry, including redox sensitive species for a large number of samples, varied over time during...

  17. Emergency core cooling system

    International Nuclear Information System (INIS)

    Ando, Masaki.

    1987-01-01

    Purpose: To actuate an automatic pressure down system (ADS) and a low pressure emergency core cooling system (ECCS) upon water level reduction of a nuclear reactor other than loss of coolant accidents (LOCA). Constitution: ADS in a BWR type reactor is disposed for reducing the pressure in a reactor container thereby enabling coolant injection from a low pressure ECCS upon LOCA. That is, ADS has been actuated by AND signal for a reactor water level low signal and a dry well pressure high signal. In the present invention, ADS can be actuated further also by AND signal of the reactor water level low signal, the high pressure ECCS and not-operation signal of reactor isolation cooling system. In such an emergency core cooling system thus constituted, ADS operates in the same manner as usual upon LOCA and, further, ADS is operated also upon loss of feedwater accident in the reactor pressure vessel in the case where there is a necessity for actuating the low pressure ECCS, although other high pressure ECCS and reactor isolation cooling system are not operated. Accordingly, it is possible to improve the reliability upon reactor core accident and mitigate the operator burden. (Horiuchi, T.)

  18. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  19. Local mechanical properties of LFT injection molded parts: Numerical simulations versus experiments

    Science.gov (United States)

    Desplentere, F.; Soete, K.; Bonte, H.; Debrabandere, E.

    2014-05-01

    In predictive engineering for polymer processes, the proper prediction of material microstructure from known processing conditions and constituent material properties is a critical step forward properly predicting bulk properties in the finished composite. Operating within the context of long-fiber thermoplastics (LFT, length Autodesk Simulation Moldflow Insight 2014 software has been used. In this software, a fiber breakage algorithm for the polymer flow inside the mold is available. Using well known micro mechanic formulas allow to combine the local fiber length with the local orientation into local mechanical properties. Different experiments were performed using a commercially available glass fiber filled compound to compare the measured data with the numerical simulation results. In this investigation, tensile tests and 3 point bending tests are considered. To characterize the fiber length distribution of the polymer melt entering the mold (necessary for the numerical simulations), air shots were performed. For those air shots, similar homogenization conditions were used as during the injection molding tests. The fiber length distribution is characterized using automated optical method on samples for which the matrix material is burned away. Using the appropriate settings for the different experiments, good predictions of the local mechanical properties are obtained.

  20. Syringe vending machines for injection drug users: an experiment in Marseille, France.

    Science.gov (United States)

    Obadia, Y; Feroni, I; Perrin, V; Vlahov, D; Moatti, J P

    1999-01-01

    OBJECTIVES: This study evaluated the usefulness of vending machines in providing injection drug users with access to sterile syringes in Marseille, France. METHODS: Self-administered questionnaires were offered to 485 injection drug users obtaining syringes from 32 pharmacies, 4 needle exchange programs, and 3 vending machines. RESULTS: Of the 343 respondents (response rate = 70.7%), 21.3% used the vending machines as their primary source of syringes. Primary users of vending machines were more likely than primary users of other sources to be younger than 30 years, to report no history of drug maintenance treatment, and to report no sharing of needles or injection paraphernalia. CONCLUSIONS: Vending machines may be an appropriate strategy for providing access to syringes for younger injection drug users, who have typically avoided needle exchange programs and pharmacies. PMID:10589315

  1. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  2. Experimental study of curved guide tubes for pellet injection

    International Nuclear Information System (INIS)

    Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gouge, M.J.; Jernigan, T.C.; Milora, S.L.

    1997-01-01

    The use of curved guide tubes for transporting frozen hydrogen pellets offers great flexibility for pellet injection into plasma devices. While this technique has been previously employed, an increased interest in its applicability has been generated with the recent ASDEX Upgrade experimental data for magnetic high-field side (HFS) pellet injection. In these innovative experiments, the pellet penetration appeared to be significantly deeper than for the standard magnetic low-field side injection scheme, along with corresponding greater fueling efficiencies. Thus, some of the major experimental fusion devices are planning experiments with HFS pellet injection. Because of the complex geometries of experimental fusion devices, installations with multiple curved guide tube sections will be required for HFS pellet injection. To more thoroughly understand and document the capability of curved guide tubes, an experimental study is under way at the Oak Ridge National Laboratory (ORNL). In particular, configurations and pellet parameters applicable for the DIII-D tokamak and the International Thermonuclear Experimental Reactor (ITER) were simulated in laboratory experiments. Initial test results with nominal 2.7- and 10-mm-diam deuterium pellets are presented and discussed

  3. Emulsion sheet doublets as interface trackers for the OPERA experiment

    International Nuclear Information System (INIS)

    Anokhina, A; Aoki, S; Ariga, A; Arrabito, L; Autiero, D; Brugiere, T; Chaussard, L; Badertscher, A; Bay, F; Greggio, F Bersani; Bertolin, A; Besnier, M; Bick, D; Bozza, C; Brugnera, R; Carrara, E; Brunetti, G; Buontempo, S; Cazes, A; Chernyavsky, M

    2008-01-01

    New methods for efficient and unambiguous interconnection between electronic position sensitive detectors and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment, that aims at detecting ν μ ν τ oscillations in the CNGS neutrino beam, is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector, on-site large-scale treatments of the emulsions (''refreshing'') have been applied. Changeable Sheet (CSd) packages, each made of a doublet of emulsion films, have been designed, assembled and coupled to the OPERA target units (''ECC bricks''). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronically tagged penetrating muons. Further improvement of in-doublet film alignment was obtained by matching the pattern of low-energy electron tracks. The commissioning of the overall OPERA alignment procedure is in progress

  4. Review: study of single-pellet injection experiments and development of pellet injector in JFT-2M

    International Nuclear Information System (INIS)

    Kasai, Satoshi; Miura, Yukitoshi; Hasegawa, Kouichi; Sengoku, Seio

    1987-10-01

    The single pellet injector developed for JFT-2M and the improvement of plasma characteristics in the auxiliary-heated discharges by single-pellet injection are reviewed for the period 1982 - 1986. The pellet injector is a pneumatic type and the designed pellet size is 1.65 mmD x 1.65 mmL and 1 mmD x 1 mmL. The hydrogen, deuterium and mixed (H 2 + D 2 ) pellets can be produced with good reproducibility. Maximum pellet velocity is about 970 m/s (pellet is deuterium and propellant gas is hydrogen). In the pellet injection experiments into auxiliary-heated (NB, ICRF) divertor or limiter discharges, the plasma confinement time is improved by a factor of 1.4 - 1.7 compared with the confinement time in the Ohmic discharges. The achieved confinement time is longer than that on the high confinement mode (H-mode) in gas fueled discharges, although the phenomena are transient. (author)

  5. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  6. Cardiac Procedures and Surgeries

    Science.gov (United States)

    ... for Heart.org CPR & ECC for Heart.org Shop for Heart.org Causes for Heart.org Advocate ... injecting a clot-dissolving agent to restore blood flow in a coronary artery ( View an illustration of ...

  7. Sub-stratum injection of fine tailings

    Energy Technology Data Exchange (ETDEWEB)

    Kesteren van, W.; Cornelisse, J.; Costello, M. [Deltares, Delft (Netherlands)

    2010-07-01

    This PowerPoint presentation discussed an experiment conducted to evaluate the sub-stratum injection of oil sands fine tailings. The hydraulic fracturing method was developed as a sub-surface dredging process for mining sand without removing the overburden. Pressure was used to transport the sand-water mixture, and the high pressures used in the process resulted in water losses through the clay-sand interface. The experiment was conducted with soft clay, compacted sand, and an injection feed. Results of the study showed that the injection method may be successful. However, further research is required to characterize the fracture energy of oil sands and the rheology of fine tailings. Horizontal hydraulic fracturing equations were presented. Tensile failures in clay and oil sands were discussed. Fractures were identified by deformation and discharge rates. Crack propagation methods were also studied. tabs., figs.

  8. Evaluation on operation of liquid relief valves for steam line break accidents by RELAP5/CANDU+ code

    International Nuclear Information System (INIS)

    Yang, C. Y.; Bang, Y. S.; Kim, H. J.

    2001-01-01

    A development of RELAP5/CANDU+ code for regulatory audits of accident analysis of CANDU nuclear power plants is on progress. This paper is undertaken in a procedure of a verification and validation for RELAP5/CANDU+ code by analyzing main steam line break accidents of WS 2/3/4. Following the ECC injection in sequence of the steam line breaks, the mismatch in heat transfer between the primary and the secondary systems makes pressure of the primary system instantly peaked to the open setpoint of liquid relief valves. The event sequence follows the result of WS 2/3/4 FSAR, but there is a difference in pressure transient after ECC injection. Sensitivity analysis for main factors dependent on the peak pressure such as control logics of liquid relief valves. ECC flow path and feedwater flow is performed. Because the pressure increase is continued for a long time and its peaking is high, open and close of the liquid relief valves are repeated several times, which is obviously different from those of WS 2/3/4 FSAR. As a result, it is evaluated that conservative modeling for the above variables is required in the analysis

  9. An analysis of CSNI standard problem, No. 8

    International Nuclear Information System (INIS)

    Sasaki, Shinobu; Araya, Fumimasa

    1980-03-01

    The CSNI International Standard Problem (ISP8), based on the Semiscale S-06-3 Test, was analyzed in the course of verification work of the computer code ALARM-P1. In this report, described was the result of the initial trial, which had been submitted to the CSNI. Due to the limitations of ALARM-P1 capability, only the blowdown portion of the transient was calculated. Though the hydraulic behavior before ECCS injection agreed with the test data, the ALARM-P1 could not continue calculation after 26 seconds due to severe predicted instability following the ECCS injection. The prediction of surface temperature of the heater rods was also unsatisfactory. Several problems to be improved have been identified both in the analytical model and the input data. (author)

  10. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China.

    Science.gov (United States)

    Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.

  11. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented including the following: Raft River Valley, Salton Sea, East Mesa, Otake, Hatchobaru, and Ahuachapan geothermal fields.

  12. Prediction of ROSA-III experiment Run 702

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Soda, Kunihisa; Kikuchi, Osamu.

    1978-11-01

    The purpose of the ROSA-III experiment with a scaled BWR test facility is to examine primary coolant thermalhydraulic behavior and performance during a postulated loss-of-coolant accident of BWR. The results provide information for verification and improvement of reactor safety analysis codes. Run 702 assumes a recirculation line double ended break at the pump suction with average core power and no ECCS. Prediction of the Run 702 experiment was made with computer code RELAP-4J. What determine the coolant behavior are mixture level in the downcomer and flowrates and flow directions at jet pump drive flow nozzle, jet pump suction and discharge. There is thus the need for these measurements to compare predicted results with experimental ones. The liquid level formation model also needs improvement. (author)

  13. Early Experience in 100 Consecutive Patients With Injection Adipocytolysis for Neck Contouring With ATX-101 (Deoxycholic Acid).

    Science.gov (United States)

    Shridharani, Sachin M

    2017-07-01

    Deoxycholic acid (DCA) is approved for improvement in the appearance of moderate to severe convexity or fullness associated with submental fat. To assess early treatment experience with DCA injection in a clinical practice setting. In this single-center, prospective, single-arm, observational study, 100 consecutive patients seeking to decrease submental fullness received subcutaneous DCA (2 mg/cm) injections in the submental area (maximum of 6 sessions at ≥1 month intervals). Treatment response was assessed 1 and 5 to 7 weeks posttreatment using the clinician-reported submental fat rating scale (CR-SMFRS) and retrospective independent photograph review by 2 physicians. Overall, 100 patients had 152 treatment sessions (58, 33, 8, and 1 patients had 1, 2, 3, and 4 sessions, respectively). CR-SMFRS score improved by ≥1 point from baseline in 88 (88%) patients; of these, 46, 33, 8, and 1 patients had 1, 2, 3, and 4 sessions, respectively. Local edema, numbness, and tenderness were reported for a mean (SD) of 7.7 (5.3), 28.5 (11.4), and 3.5 (3.5) days, respectively. Two patients experienced marginal mandibular nerve paresis. Deoxycholic acid injection, a minimally invasive procedure for neck contouring, was effective and generally well tolerated in the private practice setting.

  14. Impact of CO2 injection protocol on fluid-solid reactivity: high-pressure and temperature microfluidic experiments in limestone

    Science.gov (United States)

    Jimenez-Martinez, Joaquin; Porter, Mark; Carey, James; Guthrie, George; Viswanathan, Hari

    2017-04-01

    Geological sequestration of CO2 has been proposed in the last decades as a technology to reduce greenhouse gas emissions to the atmosphere and mitigate the global climate change. However, some questions such as the impact of the protocol of CO2 injection on the fluid-solid reactivity remain open. In our experiments, two different protocols of injection are compared at the same conditions (8.4 MPa and 45 C, and constant flow rate 0.06 ml/min): i) single phase injection, i.e., CO2-saturated brine; and ii) simultaneous injection of CO2-saturated brine and scCO2. For that purpose, we combine a unique high-pressure/temperature microfluidics experimental system, which allows reproducing geological reservoir conditions in geo-material substrates (i.e., limestone, Cisco Formation, Texas, US) and high resolution optical profilometry. Single and multiphase flow through etched fracture networks were optically recorded with a microscope, while processes of dissolution-precipitation in the etched channels were quantified by comparison of the initial and final topology of the limestone micromodels. Changes in hydraulic conductivity were quantified from pressure difference along the micromodel. The simultaneous injection of CO2-saturated brine and scCO2, reduced the brine-limestone contact area and also created a highly heterogeneous velocity field (i.e., low velocities regions or stagnation zones, and high velocity regions or preferential paths), reducing rock dissolution and enhancing calcite precipitation. The results illustrate the contrasting effects of single and multiphase flow on chemical reactivity and suggest that multiphase flow by isolating parts of the flow system can enhance CO2 mineralization.

  15. Numerical simulation of MH growth/dissociation by hot water injection on the Lab. experiment

    Science.gov (United States)

    Temma, N.; Sakamoto, Y.; Komai, T.; Yamaguchi, T.; Pawar, R.; Zyvoloski, G.

    2005-12-01

    Methane Hydrate (MH) is considered to be one of the new-generation energy resources. Aiming to develop the method of extraction of methane gas from MH, laboratory experiments have been performed in order to grasp the MH property in the National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba in Japan. In this paper, we present the results of the numerical simulation of experiment using by the hot water injection. In this calculation, FEHM (Finite Element Heat and Mass transfer) code is used. This code is developed at Los Alamos National Laboratory. In this experiment, temperature, pressure and cumulative gas production were measured. From these data, we suppose that MH growth/dissociation occurred by the flow of the hot water. And we make the model of the growth/dissociation. As this model consist of many parameters, it is difficult to determine parameters. Thus, we use PEST (Parameter ESTimation ) in order to determine parameters for the model of the MH growth/ dissociation. We use temperature data of experiment, as observed data. We make two observed data sets at the beginning and later term of experiment. At the results of PEST, we obtain two sets of parameters to get good match the observed data. We think that these sets indicate both the maximum and the minimum values of the MH growth/dissociation model. And, on this range, we continue to calculate until we get the good match. Finally, we obtain the numerical model of the experiment. Also, we conducted the sensitive analysis for the MH growth/ dissociation using this model.

  16. Evaluation of non-condensable gas effect during LBLOCA in an OPR1000 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seung Hun; Seul, Kwang-Won; Bang, Young-Seok; Lee, Jun Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-05-15

    Gas accumulation in the nuclear power plant may cause diverse safety issues such as water hammer, pump cavitation and inadvertent valve actuation. The Nuclear Regulatory Commission (NRC) has published twenty Information Notices, two Generic Letters, and one NUREG report related to the issue of the gas accumulation. It has been considered that gas accumulation occurred since the beginning of commercial nuclear power plant operation and may occur in the currently operating plants. Gas accumulation in the Emergency Core Cooling System (ECCS) is the condition that did not consider in Accident Analysis of Final Safety Analysis Report or Technical Specification and may finally result in degradation or loss of the safety functions. In this paper, the effect of gas accumulation in the ECCS has been analyzed by modeling non-condensable gas injection during the operation of Safety Injection Tank (SIT) and Low Pressure Safety Injection (LPSI) under the LBLOCA condition. Gas accumulation in the ECCS has been dealt with one of significant safety issues in the operating nuclear power plants. In order to identify the effect of the non-condensable gas in Hanul unit 3 and 4, the sensitivity studies for gas quantity, location or injection time was conducted for high or low pressure condition. At high pressure condition, the injected gas induced the reduced SIT flow rate and the reduced period of SIT injection. The reflood PCT at 5 ft''3 condition was 1150 K which was 49K higher than that at no gas condition. At low pressure condition, the reduced flow rate and the increased reflood PCT were also identified. However, the PCT deviation due to different gas quantity was not large as much as that at high pressure condition. We concluded that it is necessary to evaluate the effect of the accumulated gas with the consideration of plant- specific conditions such as system pressure, accumulated location, gas quantity and injection time.

  17. Event classification with the electronic detectors of the OPERA experiment using neural networks

    International Nuclear Information System (INIS)

    Hierholzer, Martin C.

    2012-02-01

    The OPERA experiment searches for ν μ ν τ oscillations in appearance mode. It uses the emulsion cloud chamber (ECC) technique for a high spatial resolution combined with on-line components for event localisation and muon identification. The analysis of events in an ECC detector takes considerable time, especially in case of ν τ /ν e candidate events. A ranking of events by a probability for being a ν τ /ν e event can speed up the analysis of the OPERA experiment. An algorithm for such an event ranking based on a classification-type neural network is presented in this thesis. Almost all candidate events can be found within the first 30% of the analysed events if the described ranking is applied. This event ranking is currently applied for testing purposes by the OPERA collaboration, a decision on a full application for the whole analysis is pending. A similar neural network is used for discrimination between neutral and charged current events. This is used to observe neutrino oscillations in disappearance mode with the on-line components of the OPERA detector by measuring the energy dependence of the fraction of neutral current interactions. The confidence level of the observed oscillation effect is 87%. Assuming full mixing, the mass splitting has been determined to vertical stroke Δm 2 32 vertical stroke =2.8 -1.7 +1.4 .10 -3 eV 2 .

  18. Gas injection in EBT-S for assessment of particle loading effects of neutral beam injection

    International Nuclear Information System (INIS)

    Carpenter, K.H.; Glowienka, J.C.

    1979-01-01

    Experiments have begun to examine the physics of neutral beam injection on EBT-S. Preliminary experiments have been limited to a calibrated gas puffing experiment which simulates the effects of a pulsed beam with zero energy. These experiments begin to address some of the compatibility problems that exist for future beam heating experiments on EBT devices. In particular, neutral beams are to be a significant part of the planned EBT-II experiment which is designed to demonstrate steady-state, reactor-like conditions with both electron cyclotron heating and neutral beam heating

  19. Deuterium pellet injection in the TFR Tokamak

    International Nuclear Information System (INIS)

    Lazare, O.

    1985-07-01

    Injecting fresh fuel deep inside the plasma of a thermonuclear reactor appears to be necessary; the only way to do that is to inject fast solid deuterium pellets. The existing theoretical, technical and experimental aspects of this method are presented. The experiments on TFR have confirmed that injecting pellets is technically feasible; a new kind of injector is presented. The injection does not degrade stability nor confinement of the plasma. The study of the transient phenomena occuring during the injection has proved to be an efficient way to investigate particles and energy transport in the discharge; in particular, a fast transport phenomenon, similar to those occuring during disruptions, has been studied in details. Conclusions about disruptions are drawn. (Ref 101) [fr

  20. Visualization study of interaction with 2-D film flow on the vertical plate and lateral air velocity for DVI system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Sol; Lee, Jae Young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong Jin; Kim, Jong Rok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness. In this study, the average flow information of the downcomer was analyzed through the information about the thickness, speed, droplet size and speed of highly precise liquid film flow in the structure that occurs in a 2-dimensional liquid film flow, rather than film flow, onset of entrainment, droplet velocity, and size which have been studied in 1-dimension of the existing annular flow. The multi-dimensional flow characteristic information of downcomer can be utilized as the basic data for nuclear safety analysis in the future.

  1. Pressurized thermal shock. Thermo-hydraulic conditions in the CNA-I reactor pressure vessel

    International Nuclear Information System (INIS)

    Ventura, Mirta A.; Rosso, Ricardo D.

    2002-01-01

    In this paper we analyze several reports issued by the Utility (Nucleo Electrica S.A.) and related to Reactor Pressure Vessel (RPV) phenomena in the CNA-I Nuclear Power Plant. These analyses are aimed at obtaining conclusions and establishing criteria ensuring the RPV integrity. Special attention was given to the effects ECCS cold-water injection at the RPV down-comer leading to pressurized thermal shock scenarios. The results deal with hypothetical primary system pipe breaks of different sizes, the inadvertent opening of the pressurizer safety valve, the double guillotine break of a live steam line in the containment and the inadvertent actuation pressurizer heaters. Modeling conditions were setup to represent experiments performed at the UPTF, under the hypothesis that they are representative of those that, hypothetically, may occur at the CNA-I. No system scaling analysis was performed, so this assertion and the inferred conclusions are no fully justified, at least in principle. The above mentioned studies, indicate that the RPV internal wall surface temperature will be nearly 40 degree. It was concluded that they allowed a better approximation of PTS phenomena in the RPV of the CNA-I. Special emphasis was made on the influence of the ECCS systems on the attained RPV wall temperature, particularly the low-pressure TJ water injection system. Some conservative hypothesis made, are discussed in this report. (author)

  2. Experiments on the behaviour of thermite melt injected into sodium: Final report on the THINA test results

    International Nuclear Information System (INIS)

    Huber, F.; Kaiser, A.; Peppler, W.

    1994-01-01

    During hypothetical accidents of fast breeder reactors the core melts and part of the core material inventory is ejected into the upper coolant plenum. As a consequence, a fuel to coolant thermal interaction occurs between the melt and the sodium. A series of simulating experiments was carried out in KfK/IRS to improve the knowledge about the phenomenology of molten fuel/coolant interactions and to support theoretical work on the safety of fast breeder reactors. In the tests, a thermite melt of up to 3270 K is injected from below into a sodium pool the temperature of which is between 770 and 820 K. The masses of the melt and the sodium are about five and 150 kg, respectively. Thermal interactions have been observed to occur as a sequence of small local pressure events mainly during the melt injection. Large-scale vapour explosions have not been observed. Generally, the conversion ratios of thermal to mechanical energy have been low. (author)

  3. Innovation in pediatric clinical education: application of the essential competencies.

    Science.gov (United States)

    Kenyon, Lisa K; Birkmeier, Marisa; Anderson, Deborah K; Martin, Kathy

    2015-01-01

    At the Section on Pediatrics Education Summit in July 2012, consensus was achieved on 5 essential core competencies (ECCs) that represent a knowledge base essential to all graduates of professional physical therapist education programs. This article offers suggestions for how clinical instructors (CIs) might use the ECCs to identify student needs and guide student learning during a pediatric clinical education experience. Pediatric CIs potentially might choose to use the ECCs as a reference tool in clinical education to help (1) organize and develop general, clinic-specific clinical education objectives, (2) develop and plan individualized student learning experiences, (3) identify student needs, and (4) show progression of student learning from beginner to intermediate to entry level. The ECCs may offer CIs insights into the role of pediatric clinical education in professional physical therapist education.

  4. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China

    Directory of Open Access Journals (Sweden)

    Zhu LL

    2014-03-01

    Full Text Available Ling-ling Zhu,1 Wei Li,2 Ping Song,3 Quan Zhou3 1Geriatric VIP Ward, Division of Nursing, 2Division of Medical Administration, 3Department of Pharmacy, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People's Republic of China Abstract: The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1 improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2 complications associated with vascular access; 3 incidents induced by absence of efficient electronic pump management and infusion tube management; and 4 liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan–do–check–act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety. Keywords

  5. Current drive by spheromak injection into a tokamak

    International Nuclear Information System (INIS)

    Brown, M.R.; Bellan, P.M.

    1990-01-01

    The authors report the first observation of current drive by spheromak injection into a tokamak due to the process of helicity injection. Current drive is observed in Caltech's ENCORE tokamak (30% increase, ΔI > 1 kA) only when both the tokamak and injected spheromak have the same sign of helicity (where helicity is defined as positive if current flows parallel to magnetic field lines and negative if anti-parallel). The initial increase (decrease) in current is accompanied by a sharp decrease (increase) in loop voltage and the increase in tokamak helicity is consistent with the helicity content of the injected spheromak. In addition, the injection of the spheromak raises the tokamak central density by a factor of six. The introduction of cold spheromak plasma causes sudden cooling of the tokamak discharge from 12 eV to 4 eV which results in a gradual decline in tokamak plasma current by a factor of three. In a second experiment, the authors inject spheromaks into the magnetized toroidal vacuum vessel (with no tokamak plasma). An m = 1 magnetic structure forms in the vessel after the spheromak undergoes a double tilt; once in the cylindrical entrance between gun and tokamak, then again in the tokamak vessel. A horizontal shift of the spheromak equilibrium is observed in the direction opposite that of the static toroidal field. In the absence of net toroidal flux, the structure develops a helical pitch as predicted by theory. Experiments with a number of refractory metal coatings have shown that tungsten and chrome coatings provide some improvement in spheromak parameters. They have also designed and will soon construct a larger, higher current spheromak gun with a new accelerator section for injection experiments on the Phaedrus-T tokamak

  6. Numerical simulation of thermal stratification in cold legs by using openFOAM

    International Nuclear Information System (INIS)

    Cai, Jiejin; Watanabe, Tadashi

    2010-01-01

    During a small-break loss-of-coolant accident in pressurized water reactors (PWRs), emergency core cooling system (ECCS) is actuated and cold water is injected into cold legs. Insufficient mixing of injected cold water and hot primary coolant results in thermal stratification, which is a matter of concern for evaluation of pressurized thermal shock (PTS) in view of aging and life extension of nuclear power plants. In this study, an open source CFD software, OpenFOAM, is used to simulate mixing and thermal stratification in the cold leg of ROSA/LSTF, which is the largest thermal-hydraulic integral test facility simulating PWR. One of the cold-leg is numerically simulated from the outlet of primary coolant pump to the inlet of downcomer. ECCS water is injected from injection nozzle connected at the top of the cold leg into the steady-state natural circulation flow under high-pressure and high-temperature conditions. The temperature distribution in the cold leg is compared with experimental and FLUENT's results. Effects of turbulent flow models and secondary flow due to the elbow section of the cold leg are discussed for the case with the single-phase natural circulation. Injection into a two-phase stratified flow is also simulated and predictive and numerical capabilities of OpenFOAM are discussed. (author)

  7. EMC3-EIRENE modeling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Lore, J.D., E-mail: lorejd@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Reinke, M.L. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); LaBombard, B. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Lipschultz, B. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Churchill, R.M. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Feng, Y. [Max Planck Institute for Plasma Physics, Greifswald (Germany)

    2015-08-15

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ∼50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modeling, with the simulation yielding a toroidal asymmetry in the heat flow to the outer strike point. Toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.

  8. Two-phase CFD PTS validation in an extended range of thermohydraulics conditions covered by the COSI experiment

    International Nuclear Information System (INIS)

    Coste, P.; Ortolan, A.

    2014-01-01

    Highlights: • Models for large interfaces in two-phase CFD were developed for PTS. • The COSI experiment is used for NEPTUNE C FD integral validation. • COSI is a PWR cold leg scaled 1/100 for volume. • Fifty runs are calculated, covering a large range of flow configurations. • The CFD predicting capability is analysed using global and local measurements. - Abstract: In the context of the Pressurized Water Reactors (PWR) life duration safety studies, some models were developed to address the Pressurized Thermal Shock (PTS) from the two-phase CFD angle, dealing with interfaces much larger than cells size and with direct contact condensation. Such models were implemented in NEPTUNE C FD, a 3D transient Eulerian two-fluid model. The COSI experiment is used for its integral validation. It represents a cold leg scaled 1/100 for volume and power from a 900 MW PWR under a large range of LOCA PTS conditions. In this study, the CFD is evaluated in the whole range of parameters and flow configurations covered by the experiment. In a first step, a single choice of mesh and CFD models parameters is fixed and justified. In a second step, fifty runs are calculated. The CFD predicting capability is analysed, comparing the liquid temperature and the total condensation rate with the experiment, discussing their dependency on the inlet cold liquid rate, on the liquid level in the cold leg and on the difference between co-current and counter-current runs. It is shown that NEPTUNE C FD 1.0.8 calculates with a fair agreement a large range of flow configurations related to ECCS injection and steam condensation

  9. VUV spectroscopy in impurity injection experiments at KSTAR using prototype ITER VUV spectrometer

    Science.gov (United States)

    Seon, C. R.; Hong, J. H.; Song, I.; Jang, J.; Lee, H. Y.; An, Y. H.; Kim, B. S.; Jeon, T. M.; Park, J. S.; Choe, W.; Lee, H. G.; Pak, S.; Cheon, M. S.; Choi, J. H.; Kim, H. S.; Biel, W.; Bernascolle, P.; Barnsley, R.

    2017-08-01

    The ITER vacuum ultra-violet (VUV) core survey spectrometer has been designed as a 5-channel spectral system so that the high spectral resolving power of 200-500 could be achieved in the wavelength range of 2.4-160 nm. To verify the design of the ITER VUV core survey spectrometer, a two-channel prototype spectrometer was developed. As a subsequent step of the prototype test, the prototype VUV spectrometer has been operated at KSTAR since the 2012 experimental campaign. From impurity injection experiments in the years 2015 and 2016, strong emission lines, such as Kr xxv 15.8 nm, Kr xxvi 17.9 nm, Ne vii 46.5 nm, Ne vi 40.2 nm, and an array of largely unresolved tungsten lines (14-32 nm) could be measured successfully, showing the typical photon number of 1013-1015 photons/cm2 s.

  10. Subcutaneous injection of thallium-201 chloride and gallium-67 citrate at acupuncture point K-3; An animal experiment and human-being study

    Energy Technology Data Exchange (ETDEWEB)

    Johg, Shiang-Bin; Wu, Chung-Chieng; Chen, Ming-Feng; Wu, Sheng-Nan (Kaohsiung Medical Coll., Taiwan (China))

    1992-09-01

    Subcutaneous (SC) injection of [sup 99m]Tc pertechnetate ([sup 99m]Tc) at acupuncture points K-3 is a new method of lower-limb radionuclide venography. To investigate the mechanism of absorption of [sup 99m]Tc from SC injected sites into vascular system, various radioisotopes such as [sup 201]Tl chloride ([sup 201]Tl) and [sup 67]Ga citrate ([sup 67]Ga) were SC injected at K-3 points in animal and human-beings experiments. It was found that [sup 99m]Tc and [sup 201]Tl were absorbed rapidly from K-3 points through venous system and into whole body soft tissue. However, [sup 67]Ga with a larger effective ionic radius than [sup 201]Tl was not absorbed throughout the observation of 5 minutes. Furthermore, intravenous administration of digitalis, a Na[sup +]-K[sup +] pump blocker, did not inhibit the absorption of [sup 99m]Tc and [sup 201]Tl after SC injection at K-3 points. These results suggest that absorption of radionuclides on SC injection at K-3 points is mainly through the passive pathway of diffusion rather than the active transport, and the effective ionic radius may be a major factor influencing the absorption rate of the radionuclides. (author).

  11. Quasi-stable injection channels in a wakefield accelerator

    CERN Document Server

    Wiltshire-Turkay, Mara; Pukhov, Alexander

    2016-01-01

    Particle-driven plasma-wakefield acceleration is a promising alternative to conventional electron acceleration techniques, potentially allowing electron acceleration to energies orders of magnitude higher than can currently be achieved. In this work we investigate the dependence of the energy gain on the position at which electrons are injected into the wake. Test particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the centre of the wake. The result is relevant to the planning and tuning of experiments making use of external injection.

  12. [Reducing fear in preschool children receiving intravenous injections].

    Science.gov (United States)

    Hsieh, Yi-Chuan; Liu, Hui-Tzu; Cho, Yen-Hua

    2012-06-01

    Our pediatric medical ward administers an average of 80 intravenous injections to preschool children. We found that 91.1% exhibit behavior indicative of fear and anxiety. Over three-quarters (77.8%) of this number suffer severe fear and actively resist receiving injections. Such behavior places a greater than normal burden on human and material resources and often gives family members negative impressions that lower their trust in the healthcare service while raising nurse-patient tensions. Using observation and interviews, we found primary factors in injection fear to be: Past negative experiences, lack of adequate prior communication, measures taken to preemptively control child resistance, and default cognitive behavioral strategies from nursing staff. This project worked to develop a strategy to reduce cases of severe injection fear in preschool children from 77.8% to 38.9% and achieve a capacity improvement target for members of 50%. Our team identified several potential strategy solutions from research papers and books between August 1st, 2009 and April 30th, 2010. Our proposed method included therapeutic games, self-selection of injection position, and cognitive behavioral strategies to divert attention. Other measures were also specified as standard operating procedures for administering pediatric intravenous injections. We applied the strategy on 45 preschool children and identified a post-injection "severe fear" level of 37.8%. This project was designed to reduce fear in children to make them more accepting of vaccinations and to enhance children's positive treatment experience in order to raise nursing care quality.

  13. CFD analysis of poison injection in AHWR calandria

    International Nuclear Information System (INIS)

    Kansal, A.K.; Kamble, M.T.; Maheshwari, N.K.; Vijayan, P.K.

    2014-01-01

    The present work intends to give details of design and performance validation of SDS-2. The performance is evaluated on the basis of dispersion of poison in calandria in a given period of time. Location of injection tube and injection holes, size of jet hole and number of holes are some of the design parameters which greatly affect dispersion of poison in calandria. A Computational Fluid Dynamic (CFD) study for axial and radial injection of poison was carried out using open source CFD code OpenFOAM. CFD benchmarking was done using experiments performed by Johari (Johari et al. 1997) to identify suitable turbulence model for this problem. An experimental facility simulating poison injection in moderator in presence of calandria tubes was used to further validate the CFD model is shown in the paper. CFD analysis was carried out for axial as well as radial injection for AHWR geometry. CFD analysis using OpenFOAM has been carried out to study high pressure poison injection for single jet of Shut Down System - 2 (SDS- 2) of Advanced Heavy Water Reactor (AHWR) for various design options. CFD model used in analysis have been validated with experimental data available in literature as well as experiments performed for AHWR specific geometry. Various turbulence models are tested and their adequacy for such flow problems has been established. The CFD model is then used to simulate poison injection for two design options for AHWR and their performance is compared. (author)

  14. Assessment of RANS CFD modelling for pressurised thermal shock analysis

    International Nuclear Information System (INIS)

    Sander M Willemsen; Ed MJ Komen; Sander Willemsen

    2005-01-01

    Full text of publication follows: The most severe Pressurised Thermal Shock (PTS) scenario is a cold water Emergency Core Coolant (ECC) injection into the cold leg during a LOCA. The injected ECC water mixes with the hot fluid present in the cold leg and flows towards the downcomer where further mixing takes place. When the cold mixture comes into contact with the Reactor Pressure Vessel (RPV) wall, it may lead to large temperature gradients and consequently to high stresses in the RPV wall. Knowledge of these thermal loads is important for RPV remnant life assessments. The existing thermal-hydraulic system codes currently applied for this purpose are based on one-dimensional approximations and can, therefore, not predict the complex three-dimensional flows occurring during ECC injection. Computational Fluid Dynamics (CFD) can be applied to predict these phenomena, with the ultimate benefit of improved remnant RPV life assessment. The present paper presents an assessment of various Reynolds Averaged Navier Stokes (RANS) CFD approaches for modeling the complex mixing phenomena occurring during ECC injection. This assessment has been performed by comparing the numerical results obtained using advanced turbulence models available in the CFX 5.6 CFD code in combination with a hybrid meshing strategy with experimental results of the Upper Plenum Test Facility (UPTF). The UPTF was a full-scale 'simulation' of the primary system of the four loop 1300 MWe Siemens/KWU Pressurised Water Reactor at Grafenrheinfeld. The test vessel upper plenum internals, downcomer and primary coolant piping were replicas of the reference plant, while other components, such as core, coolant pump and steam generators were replaced by simulators. From the extensive test programme, a single-phase fluid-fluid mixing experiment in the cold leg and downcomer was selected. Prediction of the mixing and stratification is assessed by comparison with the measured temperature profiles at several locations

  15. Quarterly technical progress report on water reactor safety programs sponsored by the Nuclear Regulatory Commission's Division of Reactor Safety Research, April--June 1977

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-01

    Results from the previously conducted Semiscale Mod-1 ECC injection test series were analyzed. Testing in the LOFT counterpart test series was essentially completed, and the steam generator tube rupture test series was begun. Two tests in the alternate ECC injection test series were conducted which included injection of emergency core coolant into the upper plenum through use of the low pressure injection system. The Loss-of-Fluid Test Program successfully completed nonnuclear Loss-of-Coolant Experiment L1-4. A nuclear test, GC 2-3, in the Power Burst Facility Reactor was performed to evaluate the power oscillation method of determining gap conductance and to determine the effects of initial gap size, fill gas composition, and fuel density on the thermal performance of a light water reactor fuel rod. Additional test results were obtained relative to the behavior of irradiated fuel rods during a fast power increase and during a high power film boiling transient. Fuel model development and verification activities continued for the steady state and transient Fuel Rod Analysis Program, FRAP-S and FRAP-T. A computer code known as RELAP4/MOD7 is being developed to provide best-estimate modeling for reflood during a postulated loss-of-coolant accident (LOCA). A prediction of the fourth test in the boiling water reactor (BWR) Blowdown/Emergency Core Cooling Program was completed and an uncertainty analysis was completed of experimental steady state stable film boiling data for water flowing vertically upward in round tubes. A new multinational cooperative program to study the behavior of entrained liquid in the upper plenum and cross flow in the core during the reflood phase of a pressurized water reactor LOCA was defined.

  16. Charge exchange measurements of MHD activity during neutral beam injection in the Princeton Large Torus and the Poloidal Divertor Experiment

    International Nuclear Information System (INIS)

    Goldston, R.J.; Kaita, R.; Beiersdorfer, P.; Gammel, G.; Herndon, D.L.; McCune, D.C.; Meyerhofer, D.D.

    1987-01-01

    The horizontally scanning, multi-angle charge exchange analysers on the Princeton Large Torus (PLT) and the Poloidal Divertor Experiment (PDX) were used to study the effects of MHD activity on the background ion distribution function and on the beam ion slowing-down process during high power neutral injection. Sawtooth oscillations were observed in the fast ion flux on PLT and PDX, and measurements with neutral beams providing local neutral density enhancement indicated that the ions were transported radially when these events occurred. With near-perpendicular injection in PDX, at the lower toroidal fields necessary to maximize the plasma beta, repetitive bursts of greatly enhanced charge exchange flux were observed. These were associated with the 'fishbone' MHD instability, and a substantial depletion of the perpendicular slowing-down spectrum below the injection energy was seen. A simple phenomenological model for this loss mechanism was developed, and its use in simulation codes has been successful in providing good agreement with the experimental data. The behaviour and characteristics of this model are well matched by direct theoretical calculations. (author)

  17. Charge-exchange measurements of MHD activity during neutral beam injection in the Princeton Large Torus and the Poloidal Divertor Experiment

    International Nuclear Information System (INIS)

    Goldston, R.J.; Kaita, R.; Beiersdorfer, P.; Gammel, G.; Herndon, D.L.; McCune, D.C.; Meyerhofer, D.D.

    1986-07-01

    The horizontally scanning, multiangle charge-exchange analyzers on the Princeton Large Torus (PLT) and the Poloidal Divertor Experiment (PDX) were used to study the effects of MHD activity on the background ion distribution function and on the beam ion slowing-down process during high-power neutral injection. Sawtooth oscillations were observed in the fast ion flux on PLT and PDX, and measurements with neutral beams providing local neutral density enhancement indicate that ions are transported radially when these events occur. With near-perpendicular injection in PDX, at the lower toroidal fields necessary to maximize beta, rapid, repetitive bursts of greatly enhanced charge-exchange flux were observed. These are associated with the ''fishbone'' MHD instability, and a substantial depletion of the perpendicular slowing-down spectrum below the injection energy was seen. A simple phenomenological model for this loss mechanism was developed, and its use in simulation codes has been successful in providing good agreement with the data. The behavior and characteristics of this model are well matched by the direct theoretical calculations

  18. From Site Characterization through Safe and Successful CO2 Injection Operation to Post-injection Monitoring and Site Closure - Closing the Full Life Cycle Research at the Ketzin Pilot Site, Germany

    Science.gov (United States)

    Liebscher, Axel

    2017-04-01

    Initiated in 2004, the Ketzin pilot site near Berlin, Germany, was the first European onshore storage project for research and development on geological CO2 storage. After comprehensive site characterization the site infrastructure was build comprising three deep wells and the injection facility including pumps and storage tanks. The operational CO2 injection period started in June 2008 and ended in August 2013 when the site entered the post-injection closure period. During these five years, a total amount of 67 kt of CO2 was safely injected into an Upper Triassic saline sandstone aquifer at a depth of 630 m - 650 m. In fall 2013, the first observation well was partially plugged in the reservoir section with CO2 resistant cement; full abandonment of this well finished in 2015 after roughly 2 years of cement plug monitoring. Abandonment of the remaining wells will be finished by summer 2017 and hand-over of liability to the competent authority is scheduled for end of 2017. The CO2 injected was mainly of food grade quality (purity > 99.9%). In addition, 1.5 kt of CO2 from the oxyfuel pilot capture facility "Schwarze Pumpe" (purity > 99.7%) was injected in 2011. The injection period terminated with a CO2-N2 co-injection experiment of 650 t of a 95% CO2/5% N2 mixture in summer 2013 to study the effects of impurities in the CO2 stream on the injection operation. During regular operation, the CO2 was pre-heated on-site to 40°C prior to injection to ensure a single-phase injection process and avoid any phase transition or transient states within the injection facility or the reservoir. Between March and July 2013, just prior to the CO2-N2 co-injection experiment, the injection temperature was stepwise decreased down to 10°C within a "cold-injection" experiment to study the effects of two-phase injection conditions. During injection operation, the combination of different geochemical and geophysical monitoring methods enabled detection and mapping of the spatial and

  19. Effects of contraction mode and stimulation frequency on electrical stimulation-induced skeletal muscle hypertrophy.

    Science.gov (United States)

    Ashida, Yuki; Himori, Koichi; Tatebayashi, Daisuke; Yamada, Ryotaro; Ogasawara, Riki; Yamada, Takashi

    2018-02-01

    We compared the skeletal muscle hypertrophy resulting from isometric (Iso) or eccentric (Ecc) electrical stimulation (ES) training with different stimulation frequencies. Male Wistar rats were assigned to the Iso and Ecc groups. These were divided into three further subgroups that were stimulated at 10 Hz (Iso-10 and Ecc-10), 30 Hz (Iso-30 and Ecc-30), or 100 Hz (Iso-100 and Ecc-100). In experiment 1, the left plantarflexor muscles were stimulated every other day for 3 wk. In experiment 2, mammalian target of rapamycin complex 1 (mTORC1) signaling was investigated 6 h after one bout of ES. The contralateral right muscle served as a control (non-ES). Ecc contractions comprised forced dorsiflexion combined with ES. The peak torque and torque-time integral during ES were higher in the Ecc group than that in the Iso group in all stimulation frequencies examined. The gastrocnemius muscle weight normalized to body weight in ES side was increased compared with the non-ES side by 6, 7, and 17% in the Ecc-30, Iso-100, and Ecc-100 groups, respectively, with a greater gain in Ecc-100 than the Ecc-30 and Iso-100 groups. The p70S6K (Thr389) phosphorylation level was higher in the Ecc-30 and -100 than in the Iso-30 and -100 groups, respectively. The peak torque and torque-time integral were highly correlated with the magnitude of increase in muscle mass and the phosphorylation of p70S6K. These data suggest that ES-induced muscle hypertrophy and mTORC1 activity are determined by loading intensity and volume during muscle contraction independent of the contraction mode. NEW & NOTEWORTHY Eccentric contraction and high-frequency stimulation (HFS) are regarded as an effective way to increase muscle mass by electrical stimulation (ES) training. However, little is known about whether muscle hypertrophy is affected by contraction mode and stimulation frequency in ES training. Here, we provide the evidence that muscle hypertrophy and mammalian target of rapamycin complex 1 activity are

  20. Drug injecting and HIV risk among injecting drug users in Hai Phong, Vietnam: a qualitative analysis.

    Science.gov (United States)

    Ahmed, Tanvir; Long, Thanh Nguyen; Huong, Phan Thi; Stewart, Donald Edwin

    2015-01-29

    Hai Phong, located in northern Vietnam, has become a high HIV prevalence province among Injecting Drug Users (IDUs) since the infection shifted from the southern to the northern region of the country. Previous research indicates high levels of drug and sex related risk behaviour especially among younger IDUs. Our recent qualitative research provides a deeper understanding of HIV risk behaviour and highlights views and experiences of IDUs relating to drug injecting and sharing practices. Fifteen IDUs participated in semi-structured interviews conducted in September-October, 2012. Eligible participants were selected from those recruited in a larger scale behavioural research project and identified through screening questions. Interviews were conducted by two local interviewers in Vietnamese and were audiotaped. Ethical procedures, including informed consent and participants' understanding of their right to skip and withdraw, were applied. Transcripts were translated and double checked. The data were categorised and coded according to themes. Thematic analysis was conducted and a qualitative data analysis thematic framework was used. Qualitative analysis highlighted situational circumstances associated with HIV risks among IDUs in Hai Phong and revealed three primary themes: (i) places for injecting, (ii) injecting drugs in small groups, and (iii) sharing practices. Our results showed that shared use of jointly purchased drugs and group injecting were widespread among IDUs without adequate recognition of these as HIV risk behaviours. Frequent police raids generated a constant fear of arrest. As a consequence, the majority preferred either rail lines or isolated public places for injection, while some injected in their own or a friend's home. Price, a heroin crisis, and strong group norms encouraged collective preparation and group injecting. Risk practices were enhanced by a number of factors: the difficulty in getting new syringes, quick withdrawal management

  1. Pellet injection and toroidal confinement

    International Nuclear Information System (INIS)

    1989-12-01

    The proceedings of a technical committee meeting on pellet injection and toroidal confinement, held in Gut Ising, Federal Republic of Germany, 24-26 October, 1988, are given in this report. Most of the major fusion experiments are using pellet injectors; these were reported at this meeting. Studies of confinement, which is favorably affected, impurity transport, radiative energy losses, and affects on the ion temperature gradient instability were given. Studies of pellet ablation and effects on plasma profiles were presented. Finally, several papers described present and proposed injection guns. Refs, figs and tabs

  2. Negative hydrogen ion injection into the Zero Gradient Synchrotron

    International Nuclear Information System (INIS)

    Potts, C.W.

    1977-01-01

    In October 1976 the Zero Gradient Synchrotron (ZGS) became the first high energy proton synchrotron to use charge exchange injection in routine operations. Conversion to H - injection has been very successful, yielding record high beam intensities within the first month of use and normal (>90 percent) operating efficiencies within the second month. A brief discussion is given of the history of H - at the ZGS, the hardware uniquely associated with charge exchange injection, and the operational experience gained during the first two months of H - injection

  3. Injection of Compressed Diced Cartilage in the Correction of Secondary and Primary Rhinoplasty: A New Technique with 12 Years' Experience.

    Science.gov (United States)

    Erol, O Onur

    2017-11-01

    There are instances where small or large pockets are filled with diced cartilage in the nose, without use of wrapping materials. For this purpose, 1-cc commercial syringes were used. The obtained results were partial and incomplete. For better and improved results, the author designed new syringes, with two different sizes, which compress the diced cartilage for injection. The author presents his experience accrued over the past 12 years with 2366 primary, 749 secondary, 67 cleft lip and nose, and a total of 3182 rhinoplasties, using his new syringe design, which compresses diced cartilage and injects the diced cartilages as a conglutinate mass, simulating carved costal cartilage, but a malleable one. In 3125 patients, the take of cartilage graft was complete (98.2 percent) and a smooth surface was obtained, giving them a natural appearance. In 21 patients (0.65 percent), there was partial resorption of cartilage. Correction was performed with touch-up surgery by reinjection of a small amount of diced cartilage. In 36 patients (1.13 percent), there was overcorrection that, 1 year later, was treated by simple rasping. Compared with diced cartilage wrapped with Surgicel or fascia, the amount of injected cartilage graft is predictable because it consists purely of cartilage. The injected diced cartilage, because it is compressed and becomes a conglutinated mass, resembles a wood chip and simulates carved cartilage. It is superior to carved cartilage in that it is moldable, time saving, and gives a good result with no late show or warping. The injection takes only a few minutes.

  4. Facial volumetric correction with injectable poly-L-lactic acid.

    Science.gov (United States)

    Vleggaar, Danny

    2005-11-01

    Polymers of lactic acid'have been widely used for many years in different types of medical devices, such as resorbable sutures, intrabone implants, and soft tissue implants. Injectable poly-L-lactic acid (PLLA; Sculptra), a synthetic, biodegradable polymer, has gained widespread popularity in Europe for the treatment of facial changes associated with aging. To provide background information on injectable PLLA and to describe clinical experience with its use in Europe for facial volume enhancement. Technique varies with site of injection. Generally, the product is implanted subcutaneously or intradermally in a series of treatments. No allergy testing is required. Based on experience in more than 2,500 patients, injectable PLLA has been used successfully for the correction of nasolabial folds, mid- and lower facial volume loss, jawline laxity, and other signs of facial aging. Correction lasts for 18 to 24 months in most patients. Injectable PLLA treatment provides an excellent and prolonged correction of a variety of facial wrinkles, depressions, and laxity with a minimally invasive procedure that does not require allergy testing or a recovery period.

  5. Transverse Injection Experiment; Injection Transversale; Poslednie dostizheniya v oblasti inzhektirovaniya plazmy poperek magnitnogo polya; Inyeccion Transversal

    Energy Technology Data Exchange (ETDEWEB)

    Hammel, J. E.; Baker, D. A. [Los Alamos Scientific Laboratory, Los Alamos, NM (United States)

    1966-04-15

    The motion of a plasma stream injected transverse to a magnetic field has been discussed by several authors. In early experiments with the injection of a fast (50 to 70 cm/{mu}sec) dense (10{sup 14} ion/cm{sup 3}) plasma transverse to a magnetic field, a self polarization electric field was observed and the stream crossed the magnetic field with an E x B drift. The magnetic field was only slightly disturbed by the stream (| {Delta}B/B | <0.1) while the drift across magnetic fields up to 5 kG was at approximately the velocity of the injected stream. The height of the stream in the direction of V x B is compressed as it drifts into high magnetic field regions. At the same time, electron density measurements using interferometry techniques with the He-Ne laser show that the transverse field up to 7 kG causes no appreciable spreading of the stream to take place in the direction of B. Of interest is the action of the stream as it crosses a region where magnetic field lines reverse direction about a field null line. As the stream proceeds across the separatrix between the two field line directions, the electric field must change direction if the stream drift is to continue. The stream halts in the region of the separatrix while large currents are measured along magnetic field lines connecting the front of the stream with the following portions. Insulators placed to interrupt the current allow the stream to proceed into the reversed field region. By making use of the inductance associated with the depolarization current when magnetic field lines are tied at some distance to the side of the stream, a separation of fast and slow stream components can be made. The cutoff of the slow stream component is observed with the He-Ne laser interferometry techniques. Electric field measurements at several points along the stream show some of the more complicated features of the plasma flow. (author) [French] Le mouvement d'un faisceau de plasma injecte transversalement a un champ

  6. Injecting drug use: Gendered risk.

    Science.gov (United States)

    Zahnow, Renee; Winstock, Adam R; Maier, Larissa J; Levy, Jay; Ferris, Jason

    2018-06-01

    Research demonstrates gender related differences in drug-use practices and risk behaviours. Females' structural vulnerability stemming from traditional gender roles and gender-power relations may enhance their propensity to experience injecting related risk. In this paper we explore gender differences in injection practices at the initiation event, during the first year of injecting and in the most recent 12-month period, to inform more effective harm reduction strategies. Data used in this study were drawn from the Global Drug Survey 2015. The study employs chi-square and logistic regression to assess gender differences in injection behaviours in a sample of current injectors residing in six global regions: North-West Europe; Southern Eastern Europe; North America. South America and Oceania. Females were more likely than males to report being injected by an intimate partner at initiation (OR = 4.4, 95%CI: 2.2-8.8), during the first year of injecting (OR = 4.8, 95% CI: 2.4-9.3) and in the most recent 12-month period (OR = 2.5, 95%CI: 1.0-6.2). Females reported greater difficulties accessing sterile equipment (X 2 (2,N = 453) = 8.2, p = 0.02) and were more likely to share injecting equipment than males (X 2 (1,N = 463) = 3.9, p = 0.05). Our findings highlight females' continued dependence on their intimate partner to administer the injection into the first year of their injecting career. Females remained more likely than males to rely on intimate partners for injection during the most recent 12-month period. Females report greater difficulties in sourcing sterile equipment and are more likely to share injecting equipment. We suggest that these findings reflect the broader social structure in which females are disempowered through traditional gender roles and the lack of gender appropriate harm reduction services. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Peritumoural vs intratumoural injections in sentinel node lymphoscintigraphy

    International Nuclear Information System (INIS)

    MacFarlane, L.; Cardaci, G.

    2002-01-01

    Full text: Lymphoscintigraphy has emerged as a method of detecting sentinel lymph nodes (SLN) in breast cancer. Our department started performing these studies in 2001, using 99mTc-Colloidal Antimony Sulphide Injection -dose 30-50MBq. Two methods of injection were used: (a) peritumoural plus subdermal injection - 1.25ml volume (PT), or (b) direct intratumoural injection - 0.2ml volume (IT), both followed by 5-10 min of gentle massage. Patients with a non-palpable mass required a hookwire (HW) inserted at time of injection, and a hotpack was applied in lieu of massage. 125 patients were retrospectively assessed, with 45 PT, 37 IT, 38 HW, and 5 patients had cavity injections. For PT injections, 93% had axillary node drainage (AN), 27% had internal mammary node drainage (IM) and 4% had no drainage to nodes, despite delayed imaging. For IT injections, 84% had AN, 24% had IM, 11% showed no drainage. Of patients having HW, 66% had AN, 34% had IM, 26% no drainage. In our experience, PT injection has a higher yield for SLN localisation than direct IT injection. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  8. Experimental Investigation of Diffuser Hub Injection to Improve Centrifugal Compressor Stability

    Science.gov (United States)

    Skoch, Gary J.

    2004-01-01

    Results from a series of experiments to investigate whether centrifugal compressor stability could be improved by injecting air through the diffuser hub surface are reported. The research was conducted in a 4:1 pressure ratio centrifugal compressor configured with a vane-island diffuser. Injector nozzles were located just upstream of the leading edge of the diffuser vanes. Nozzle orientations were set to produce injected streams angled at 8, 0 and +8 degrees relative to the vane mean camber line. Several injection flow rates were tested using both an external air supply and recirculation from the diffuser exit. Compressor flow range did not improve at any injection flow rate that was tested. Compressor flow range did improve slightly at zero injection due to the flow resistance created by injector openings on the hub surface. Leading edge loading and semi-vaneless space diffusion showed trends similar to those reported earlier from shroud surface experiments that did improve compressor flow range. Opposite trends are seen for hub injection cases where compressor flow range decreased. The hub injection data further explain the range improvement provided by shroud-side injection and suggest that different hub-side techniques may produce range improvement in centrifugal compressors.

  9. Event classification with the electronic detectors of the OPERA experiment using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Hierholzer, Martin C.

    2012-02-15

    The OPERA experiment searches for {nu}{sub {mu}} <-> {nu}{sub {tau}} oscillations in appearance mode. It uses the emulsion cloud chamber (ECC) technique for a high spatial resolution combined with on-line components for event localisation and muon identification. The analysis of events in an ECC detector takes considerable time, especially in case of {nu}{sub {tau}}/{nu}{sub e} candidate events. A ranking of events by a probability for being a {nu}{sub {tau}}/{nu}{sub e} event can speed up the analysis of the OPERA experiment. An algorithm for such an event ranking based on a classification-type neural network is presented in this thesis. Almost all candidate events can be found within the first 30% of the analysed events if the described ranking is applied. This event ranking is currently applied for testing purposes by the OPERA collaboration, a decision on a full application for the whole analysis is pending. A similar neural network is used for discrimination between neutral and charged current events. This is used to observe neutrino oscillations in disappearance mode with the on-line components of the OPERA detector by measuring the energy dependence of the fraction of neutral current interactions. The confidence level of the observed oscillation effect is 87%. Assuming full mixing, the mass splitting has been determined to vertical stroke {delta}m{sup 2}{sub 32} vertical stroke =2.8{sub -1.7}{sup +1.4}.10{sup -3}eV{sup 2}.

  10. Prediction of Gas Injection Performance for Heterogeneous Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Blunt, Martin J.; Orr, Franklin M.

    1999-05-17

    This report describes research carried out in the Department of Petroleum Engineering at Stanford University from September 1997 - September 1998 under the second year of a three-year grant from the Department of Energy on the "Prediction of Gas Injection Performance for Heterogeneous Reservoirs." The research effort is an integrated study of the factors affecting gas injection, from the pore scale to the field scale, and involves theoretical analysis, laboratory experiments, and numerical simulation. The original proposal described research in four areas: (1) Pore scale modeling of three phase flow in porous media; (2) Laboratory experiments and analysis of factors influencing gas injection performance at the core scale with an emphasis on the fundamentals of three phase flow; (3) Benchmark simulations of gas injection at the field scale; and (4) Development of streamline-based reservoir simulator. Each state of the research is planned to provide input and insight into the next stage, such that at the end we should have an integrated understanding of the key factors affecting field scale displacements.

  11. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation

    OpenAIRE

    Karakan, Tolga; Ersoy, Erim; Hasçiçek, Metin; Özgür, Berat Cem; Özcan, Serkan; Aydın, Arif

    2012-01-01

    Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  12. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation.

    Science.gov (United States)

    Karakan, Tolga; Ersoy, Erim; Hasçiçek, Metin; Ozgür, Berat Cem; Ozcan, Serkan; Aydın, Arif

    2012-01-01

    Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  13. Confinement studies with neutral-beam injection on PDX and PLT

    Energy Technology Data Exchange (ETDEWEB)

    Goldston, R.; Kaye, S.; Davis, S.

    1982-07-01

    Neutral beam injection experiments on PLT and PDX have been conducted over a wider range in parameter space than previously. On PLT H/sup 0/ beams have been injected into well-confined high toroidal field, high density Ohmic plasmas, giving n/sub e/(0) tau/sub Ee/ products during injection of up to 5 x 10/sup 12/ sec cm/sup -3/. tau/sub Ee/ is found to rise slowly with increasing density in these experiments. Comparing these results with earlier (1979) discharges, which showed much lower heating efficiency, the importance of starting with a hot Ohmic plasma and a peaked density profile is striking. On PDX high power injection experiments over a range in plasma current have shown a significant variation with current of both ion heating and total stored plasma energy. Transport analysis of these results indicates that global confinement drops little when I/sup p/ is varied from 480 to 320 kA, but as I/sup p/ falls to 200 kA, tau/sub E/ deteriorates significantly.

  14. Pool scrubbing and hydrodynamic experiments on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.

    1995-01-01

    Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  15. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  16. Pool scrubbing and hydrodynamic experiment on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-01-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  17. The U.S. Gas Flooding Experience: CO2 Injection Strategies and Impact on Ultimate Recovery

    Energy Technology Data Exchange (ETDEWEB)

    Nunez-Lopez, Vanessa [The University of Texas at Austin; Hosseini, Seyyed; Gil-Egui, Ramon

    2017-09-29

    The Permian Basin in West Texas and southwestern New Mexico has seen 45 years of oil reserve growth through CO2 enhanced oil recovery (CO2 EOR). More than 60 CO2 EOR projects are currently active in the region’s limestone, sandstone and dolomite reservoirs. Water alternating gas (WAG) has been the development strategy of choice in the Permian for several technical and economic reasons. More recently, the technology started to get implemented in the much more porous and permeable clastic depositional systems of the onshore U.S. Gulf Coast. Continued CO2 injection (CGI), as opposed to WAG, was selected as the injection strategy to develop Gulf Coast oil fields, where CO2 injection volumes are significantly larger (up to 6 times larger) than those of the Permian. We conducted a compositional simulation based study with the objective of comparing the CO2 utilization ratios (volume of CO2 injected to produce a barrel of oil) of 4 conventional and novel CO2 injection strategies: (1) continuous gas injection (CGI), (2) water alternating gas (WAG), (3) water curtain injection (WCI), and (4) WAG and WCI combination. These injection scenarios were simulated using the GEM module from the Computer Modeling Group (CMG). GEM is an advanced general equation-of-state compositional simulator, which includes equation of state, CO2 miscible flood, CO2/brine interactions, and complex phase behavior. The simulator is set up to model three fluid phases including water, oil, and gas. Our study demonstrates how the selected field development strategy has a significant impact on the ultimate recovery of CO2-EOR projects, with GCI injection providing maximum oil recovery in absolute volume terms, but with WAG offering a more balanced technical-economical approach.

  18. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation

    Directory of Open Access Journals (Sweden)

    Tolga Karakan

    2012-01-01

    Full Text Available Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  19. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  20. Pellet injection into ASDEX upgrade plasmas

    International Nuclear Information System (INIS)

    Lang, P.T.; Zohm, H.; Buechl, K.; Fuchs, J.C.; Gehre, O.; Gruber, O.; Lang, R.S.; Mertens, V.; Neuhauser, J.; Salzmann, H.

    1996-04-01

    This work comprises results obtained using the new centrifuge injection system for the two first years of pellet injection experiments at Asdex Upgrade until the end of the 1995 experimental campaign. The main aim of the pellet injection investigation is to develop scenarios allowing for a more flexible plasma density control means of injection of cryogenic solid hydrogen pellets. Efforts have been made to develop scenarios allowing more flexible plasma density control by injecting cryogenic solid hydrogen pellets. While the injection of pellets during ohmic discharges was found to be most efficient and also improves the plasma performance, increasing the auxiliary heating power causes a detoriation of the pellet fuelling efficiency. A further strong reduction of the pellet fuelling efficiency by an additional process was observed for the more reactor-relevant conditions of shallow particle deposition during H-mode phases. With injection during type I ELMy H-mode phases, each pellet was found to trigger the release of an ELM and therefore cause particle losses mainly from the edge region. In the type I ELMy H-mode, only sufficient pellet penetration allowed noticeable, persistent particle deposition in the plasma by the pellets. Applying adequate pellet injection conditions and favourable scenarios using combined pellet/gas puff refuelling, significant density ramp-up to densities exceeding the empirical Greenwald limit by up to a factor of two was achieved even for strongly heated H-mode plasmas. (orig.)

  1. Direct injection of high pressure gas : scaling properties of pulsed turbulent jets

    NARCIS (Netherlands)

    Baert, R.S.G.; Klaassen, A.; Doosje, E.

    2010-01-01

    Existing gasoline DI injection equipment has been modified to generate single hole pulsed gas jets. Injection experiments have been performed at combinations of 3 different pressure ratios (2 of which supercritical) respectively 3 different hole geometries (i.e. length to diameter ratios). Injection

  2. Cross-field plasma injection into mirror geometry

    Energy Technology Data Exchange (ETDEWEB)

    Uzun-Kaymak, I U; Clary, R; Ellis, R; Elton, R; Teodorescu, C; Young, W [Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, MD 20742 (United States); Messer, S; Bomgardner, R; Case, A; Witherspoon, F D, E-mail: uzunkaymak@wisc.ed [HyperV Technologies Corp., Chantilly, VA 20151 (United States)

    2009-09-15

    The Maryland Centrifugal Experiment (MCX) and HyperV Technologies Corp. are collaborating on a series of experiments to test the use of a plasma gun to inject mass and momentum into a magnetic-confinement device. HyperV has designed, built and installed a prototype coaxial gun to drive rotation in MCX. The gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. Preliminary measurements at HyperV indicate the gun generates plasma jets with a mass of 160 {mu}g, velocities up to 90 km s{sup -1} and plasma density in the high 10{sup 14} cm{sup -3}. This paper emphasizes characteristics of the plasma gun and penetration of the plasma jet through the MCX magnetic field. Plans for future injection experiments are briefly discussed.

  3. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...... position was measured on the polymer μ-parts to evaluate filling behavior of the polymer melt flowing through μ-features. Experimental results obtained under different processing conditions were evaluated to correlate the process parameter levels influence on the selected responses. Results showed...... that the injection speed in one of the most influencing process parameters on the μIM process and on the μ-parts filling....

  4. CO2 Injectivity in Geological Storages: an Overview of Program and Results of the GeoCarbone-Injectivity Project

    International Nuclear Information System (INIS)

    Lombard, J.M.; Egermann, P.; Azaroual, M.; Pironon, J.; Broseta, D.; Egermann, P.; Munier, G.; Mouronval, G.

    2010-01-01

    The objective of the GeoCarbone-Injectivity project was to develop a methodology to study the complex phenomena involved in the near well bore region during CO 2 injection. This paper presents an overview of the program and results of the project, and some further necessary developments. The proposed methodology is based on experiments and simulations at the core scale, in order to understand (physical modelling and definition of constitutive laws) and quantify (calibration of simulation tools) the mechanisms involved in injectivity variations: fluid/rock interactions, transport mechanisms, geomechanical effects. These mechanisms and the associated parameters have then to be integrated in the models at the well bore scale. The methodology has been applied for the study of a potential injection of CO 2 in the Dogger geological formation of the Paris Basin, in collaboration with the other ANR GeoCarbone projects. (authors)

  5. Booster gold beam injection efficiency and beam loss

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Ahrens, L.A.

    1998-01-01

    The Relativistic Heavy Ion Collider (RHIC) at the BNL requires the AGS to provide Gold beam with the intensity of 10 9 ions per bunch. Over the years, the Tandem Van de Graaff has provided steadily increasing intensity of gold ion beams to the AGS Booster. However, the gold beam injection efficiency at the Booster has been found to decrease with the rising intensity of injected beams. As the result, for Tandem beams of the highest intensity, the Booster late intensity is lower than with slightly lower intensity Tandem beam. In this article, the authors present two experiments associated with the Booster injection efficiency and beam intensity. One experiment looks at the Booster injection efficiency by adjusting the Tandem beam intensity, and another looks at the beam life time while scraping the beam in the Booster. The studies suggest that the gold beam injection efficiency at the AGS Booster is related to the beam loss in the ring, rather than the intensity of injected beam or circulating beam. A close look at the effect of the lost gold ion at the Booster injection leads to the prediction that the lost gold ion creates large number of positive ions, and even larger number of electrons. The lost gold beam is also expected to create large numbers of neutral particles. In 1998 heavy ion run, the production of positive ions and electrons due to the lost gold beam has been observed. Also the high vacuum pressure due to the beam loss, presumably because of the neutral particles it created, has been measured. These results will be reported elsewhere

  6. Perceptions of community and family level IDU and HIV related stigma, disclosure decisions and experiences with layered stigma among HIV positive injection drug users in Vietnam

    OpenAIRE

    Rudolph, A.E.; Davis, W.W.; Quan, V.M.; Ha, T.V.; Minh, N.L.; Gregowski, A.; Salter, Megan; Celentano, D.D.; Go, V.

    2011-01-01

    This paper explores how perceived stigma and layered stigma related to injection drug use and being HIV positive influence the decision to disclose one’s HIV status to family and community and experiences with stigma following disclosure among a population of HIV positive male injection drug users (IDUs) in Thai Nguyen, Vietnam. In qualitative interviews conducted between 2007 and 2008, 25 HIV positive male IDUs described layered stigma in their community but an absence of layered stigma with...

  7. Numerical simulation of thermal stratification in cold legs by using OpenFOAM

    International Nuclear Information System (INIS)

    Cai, Jiejin; Watanabe, Tadashi

    2011-01-01

    During a small-break loss-of-coolant accident in pressurized water reactors (PWRs), emergency core cooling system (ECCS) is actuated and cold water is injected into cold legs. Insufficient mixing of injected cold water and hot primary coolant results in thermal stratification, which is a matter of concern for evaluation of pressurized thermal shock (PTS) in view of aging and life extension of nuclear power plants. In this study, an open source CFD software, OpenFOAM, is used to simulate mixing and thermal stratification in the cold leg of ROSA/LSTF, which is the largest thermal-hydraulic integral test facility simulating PWR. One of the cold-leg is numerically simulated from the outlet of primary coolant pump to the inlet of downcomer. ECCS water is injected from injection nozzle connected at the top of the cold leg into the steady-state natural circulation flow under high-pressure and high-temperature conditions. The temperature distribution in the cold leg is compared with experimental and FLUENT's results. Effects of turbulent flow models and secondary flow due to the elbow section of the cold leg are discussed for the case with the single-phase natural circulation. Injection into a two-phase stratified flow is also simulated and predictive and numerical capabilities of OpenFOAM are discussed. (author)

  8. Investigation of vertical liquid film width upon impingement on flat plate

    International Nuclear Information System (INIS)

    Kim, Won J.; Son, Hyung M.; Suh, Kune Y.

    2003-01-01

    In the early, high pressure phase during a Large-Break Loss-Of-Coolant Accident (LBLOCA), the Emergency Core Cooling (ECC) water of the Direct Vessel Injection (DVI) system is supplied from the Safety Injection Tank (SIT). After the shortage of the SIT, the In-containment Refueling Water Storage Tank (IRWST) supplies water to the safety system. Velocity of the injection flow varies during the process from the initial value of over 10 m/s in the blowdown phase to 2∼3 m/s in the later phase of reflood. During the safety injection, such important phenomena are observed as impingement, bypass, entrainment and sweepout, and condensation. The impingement is referred to the case where the ECC water is injected to strike on the reactor inner vessel. Accordingly, the water generates a liquid film to form a ridge on the wall. The liquid film then flows down the wall due to gravity. This impingement is interrupted by the steam-water mixture bypass flow to the break. The bypass, in turn, is affected by the impingement. This study is intended to understand the impinged water flow behavior neglecting such secondary effects as the temperature-dependent thermodynamic properties and the reactor vessel curvature. An emphasis is put on interpreting the results of visual inspection to understand the underlying mechanism of rather complex turbulent flow in the downcomer

  9. Power spectrum of an injection-locked Josephson oscillator

    International Nuclear Information System (INIS)

    Stancampiano, C.V.; Shapiro, S.

    1975-01-01

    Experiments have shown that a Josephson oscillator, exposed to a weak narrow-band input signal, exhibits behavior characteristic of an injection-locked oscillator. When in lock, Adler's theory of injection locking describes the experimental observations reasonably well. The range of applicability of the theory is extended to the out-of-lock regime where a spectrum of output frequencies is observed. Obtaining the theoretical output power spectrum requires solving a differential equation having the same form as the equation describing the resistively shunted junction model of Stewart and of McCumber. Experimental measurements of the output spectrum of a nearly locked Josephson oscillator are shown to be in reasonable agreement with the theory. Additional results discussed briefly include the observation of a frequency dependence of the locked Josephson oscillator output and experiments in which a Josephson oscillator-mixer was injection locked by a weak signal at the rf

  10. Research and application of zinc injection in PWRs

    International Nuclear Information System (INIS)

    Jiang Lei

    2012-01-01

    In the middle 1990s, some PWRs in USA and Germany started to inject Zinc into the reactor coolant system for reducing both radiation fields and primary water stress corrosion cracking (PWSCC). Based on data from the labs and experience in the demonstration pants, Zinc injection obviously reduced radiation fields, and effectively mitigated PWSCC. Plants in USA injected high concentration zinc that is 15 ppb to 40 ppb to restrained PWSCC. Whereas, plants in Germany injected low concentration zinc that is 5 ppb to 10 ppb to reduce radiation fields. There are more than ten years at aspect of zinc rejection in overseas PWR, but domestic plants don't add zinc. The building PWR in Zhejiang Sanmen is the first AP1000 unit in the world, according to requirement of designers, it will start to inject zinc in the initial fuel cycle. (author)

  11. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  12. Injection Methods and Instrumentation for Serial X-ray Free Electron Laser Experiments

    Science.gov (United States)

    James, Daniel

    Scientists have used X-rays to study biological molecules for nearly a century. Now with the X-ray free electron laser (XFEL), new methods have been developed to advance structural biology. These new methods include serial femtosecond crystallography, single particle imaging, solution scattering, and time resolved techniques. The XFEL is characterized by high intensity pulses, which are only about 50 femtoseconds in duration. The intensity allows for scattering from microscopic particles, while the short pulses offer a way to outrun radiation damage. XFELs are powerful enough to obliterate most samples in a single pulse. While this allows for a "diffract and destroy" methodology, it also requires instrumentation that can position microscopic particles into the X-ray beam (which may also be microscopic), continuously renew the sample after each pulse, and maintain sample viability during data collection. Typically these experiments have used liquid microjets to continuously renew sample. The high flow rate associated with liquid microjets requires large amounts of sample, most of which runs to waste between pulses. An injector designed to stream a viscous gel-like material called lipidic cubic phase (LCP) was developed to address this problem. LCP, commonly used as a growth medium for membrane protein crystals, lends itself to low flow rate jetting and so reduces the amount of sample wasted significantly. This work discusses sample delivery and injection for XFEL experiments. It reviews the liquid microjet method extensively, and presents the LCP injector as a novel device for serial crystallography, including detailed protocols for the LCP injector and anti-settler operation.

  13. Numerical research on the scroll compressor with refrigeration injection

    International Nuclear Information System (INIS)

    Wang Baolong; Shi Wenxing; Li Xianting; Yan Qisen

    2008-01-01

    A general model for a scroll compressor with refrigerant injection is established in this paper. The model can be used to predict the macro performance and inner compression process of the injected scroll compressor. A series of experiments are conducted to validate the accuracy of the model. The results show that the model can precisely predict not only the general performance of the compressor but also the inner compression with or without refrigerant injection. Based on the thermodynamic model and the test bench, the injection process of the scroll compressor has been investigated and the thermodynamic essence is revealed. It is found that the refrigerant injection process can be considered as a continual parameter-varying 'adiabatic throttling + isobaric mixture' time-varying process

  14. Injection envelope matching in storage rings

    International Nuclear Information System (INIS)

    Minty, M.G.; Spence, W.L.

    1995-05-01

    The shape and size of the transverse phase space injected into a storage ring can be deduced from turn-by-turn measurements of the transient behavior of the beam envelope in the ring. Envelope oscillations at 2 x the β-tron frequency indicate the presence of a β-mismatch, while envelope oscillations at the β-tron frequency are the signature of a dispersion function mismatch. Experiments in injection optimization using synchrotron radiation imaging of the beam and a fast-gated camera at the SLC damping rings are reported

  15. Neutral beam injection in 2XIIB

    International Nuclear Information System (INIS)

    Hibbs, S.M.

    1975-01-01

    Integrated into the operation of the 2XIIB controlled fusion experiment is a 600-A, 20-keV neutral injection system: the highest neutral-beam current capacity of any existing fusion machine. This paper outlines the requirements of the injection system and the design features to which they led. Both mechanical and electrical aspects are discussed. Also included is a brief description of some operational aspects of the system and some of the things we have learned along the way, as well as a short history of the most significant developments

  16. Micro-powder injection moulding of tungsten

    International Nuclear Information System (INIS)

    Zeep, B.

    2007-12-01

    For He-cooled Divertors as integral components of future fusion power plants, about 300000 complex shaped tungsten components are to be fabricated. Tungsten is the favoured material because of its excellent properties (high melting point, high hardness, high sputtering resistance, high thermal conductivity). However, the material's properties cause major problems for large scale production of complex shaped components. Due to the resistance of tungsten to mechanical machining, new fabrication technologies have to be developed. Powder injection moulding as a well established shaping technology for a large scale production of complex or even micro structured parts might be a suitable method to produce tungsten components for fusion applications but is not yet commercially available. The present thesis is dealing with the development of a powder injection moulding process for micro structured tungsten components. To develop a suitable feedstock, the powder particle properties, the binder formulation and the solid load were optimised. To meet the requirements for a replication of micro patterned cavities, a special target was to define the smallest powder particle size applicable for micro-powder injection moulding. To investigate the injection moulding performance of the developed feedstocks, experiments were successfully carried out applying diverse cavities with structural details in micro dimension. For debinding of the green bodies, a combination of solvent debinding and thermal debinding has been adopted for injection moulded tungsten components. To develop a suitable debinding strategy, a variation of the solvent debinding time, the heating rate and the binder formulation was performed. For investigating the thermal consolidation behaviour of tungsten components, sinter experiments were carried out applying tungsten powders suitable for micro-powder injection moulding. First mechanical tests of the sintered samples showed promising material properties such as a

  17. Amperometric detection of carbohydrates based on the glassy carbon electrode modified with gold nano-flake layer

    Directory of Open Access Journals (Sweden)

    Huy Du Nguyen

    2015-09-01

    Full Text Available An electro-deposition approach was established to incorporate the gold nano-flakes onto the glassy carbon electrode in electrochemical cells (nano-Au/GC/ECCs. Using pulsed amperometric detection (PAD without any gold oxidation for cleaning (non-oxidative PAD, the nano-Au/GC/ECCs were able to maintain their activity for oxidizing of carbohydrates in a normal alkaline medium. The reproducibility of peak area was about 2 relative standard deviation (RSD,% for 6 consecutive injections. A dynamic range of carbohydrates was obtained over a concentration range of 5–80 mg L−1 and the limits of detection (LOD were of 2 mg L−1 for fructose and lactose and 1 mg L−1 for glucose and galactose. Moreover, the nano-Au/GC/ECC using the non-oxidative PAD was able to combine with the internal standard method for determination of lactose in fresh cow milk sample.

  18. An Improved Digital Signature Protocol to Multi-User Broadcast Authentication Based on Elliptic Curve Cryptography in Wireless Sensor Networks (WSNs

    Directory of Open Access Journals (Sweden)

    Hamed Bashirpour

    2018-03-01

    Full Text Available In wireless sensor networks (WSNs, users can use broadcast authentication mechanisms to connect to the target network and disseminate their messages within the network. Since data transfer for sensor networks is wireless, as a result, attackers can easily eavesdrop deployed sensor nodes and the data sent between them or modify the content of eavesdropped data and inject false data into the sensor network. Hence, the implementation of the message authentication mechanisms (in order to avoid changes and injecting messages into the network of wireless sensor networks is essential. In this paper, we present an improved protocol based on elliptic curve cryptography (ECC to accelerate authentication of multi-user message broadcasting. In comparison with previous ECC-based schemes, complexity and computational overhead of proposed scheme is significantly decreased. Also, the proposed scheme supports user anonymity, which is an important property in broadcast authentication schemes for WSNs to preserve user privacy and user untracking.

  19. LABORATORY SCALE STEAM INJECTION TREATABILITY STUDIES

    Science.gov (United States)

    Laboratory scale steam injection treatability studies were first developed at The University of California-Berkeley. A comparable testing facility has been developed at USEPA's Robert S. Kerr Environmental Research Center. Experience has already shown that many volatile organic...

  20. Lithium pellet injection experiments on the Alcator C-Mod tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Garnier, Darren Thomas [Univ. of California, Berkeley, CA (United States)

    1996-06-01

    A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient (ℓp ℓ a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li+ emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = ∞ and the n = 1 marginal stability limits.

  1. Lithium pellet injection experiments on the Alcator C-Mod tokamak

    International Nuclear Information System (INIS)

    Garnier, D.T.

    1996-06-01

    A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient (ell p ≤ a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li + emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = ∞ and the n = 1 marginal stability limits

  2. Giant tunnel-electron injection in nitrogen-doped graphene

    DEFF Research Database (Denmark)

    Lagoute, Jerome; Joucken, Frederic; Repain, Vincent

    2015-01-01

    Scanning tunneling microscopy experiments have been performed to measure the local electron injection in nitrogen-doped graphene on SiC(000) and were successfully compared to ab initio calculations. In graphene, a gaplike feature is measured around the Fermi level due to a phonon-mediated tunneling...... and at carbon sites. Nitrogen doping can therefore be proposed as a way to improve tunnel-electron injection in graphene....

  3. Application of UPTF data for modeling liquid draindown in the downcomer region of a PWR using RELAP5/MOD2-B&W

    Energy Technology Data Exchange (ETDEWEB)

    Wissinger, G.; Klingenfus, J. [B & W Nuclear Technologies, Lynchburg, VA (United States)

    1995-09-01

    B&W Nuclear Technologies (BWNT) currently uses an evaluation model that analyzes large break loss-of-coolant accidents in pressurized water reactors using several computer codes. These codes separately calculate the system performance during the blowdown, refill, and reflooding phases of the transient. Multiple codes are used, in part, because a single code has been unable to effectively model the transition from blowdown to reflood, particularly in the downcomer region where high steam velocities do not allow the injected emergency core cooling (ECC) liquid to penetrate and begin to refill the vessel lower plenum until after the end of blowdown. BWNT is developing a method using the RELAP5/MOD2-B&W computer code that can correctly predict the liquid draindown behavior in the downcomer during the late blowdown and refill phases. Benchmarks of this method have been performed against Upper Plenum Test Facility (UPTF) data for ECC liquid penetration and valves using both cold leg and downcomer ECC injection. The use of this new method in plant applications should result in the calculation of a shorter refill period, leading to lower peak clad temperature predictions and increased core peaking. This paper identifies changes made to the RELAP/MOD2-B&W code to improve its predictive capabilities with respect to the data obtained in the UPTF tests.

  4. Quasiparticle energy distribution and relaxation times in a tunnel-injected superconductor

    International Nuclear Information System (INIS)

    Kirtley, J.R.; Kent, D.S.; Langenberg, D.N.; Kaplan, S.B.; Chang, J.; Yang, C.

    1980-01-01

    Experiments are reported in which a nonequilibrium quasiparticle distribution was created in a dirty Al film by tunnel injection and probed using a second tunnel junction. The distribution was found to have the form of a quasithermal distribution characterized by an effective temperature greater than the ambient bath temperature and dependent on injection level, plus small sharp structures which originate in structures in the injected quasiparticle distribution due to gap-edge peaks in the quasiparticle density of states. A systematic theoretical analysis of these structures correctly predicts their shapes and relative amplitudes. The amplitudes show directly the presence of branch imbalance in the nonequilibrium quasiparticle distribution. Using the theoretical model, inelastic quasiparticle relaxation and elastic branch mixing times, as functions of energy and temperature, are extracted from the experimental data without need for phonon-trapping corrections. The qualitative and quantitative behavior of these times is in reasonable accord with theoretical expectations and the results of other experiments. Experiments of the type reported here are shown to provide a kind of spectroscopy of tunnel-injection and quasiparticle-relaxation processes in superconductors

  5. Advanced fusion in ICRF injected plasmas

    International Nuclear Information System (INIS)

    Carpignano, F.; Coppi, B.; Detragiache, P.; Migliuolo, S.; Nassi, M.; Rogers, B.

    1994-01-01

    Fusion burning of a D- 3 He mixture in a high density, high magnetic field, compact toroidal experiment (Ignitor) with a high injected power density at the ion cyclotron frequency (ICRF) is investigated. A superthermal tail (with energies exceeding 1 MeV in the central part of the plasma column) is induced in the distribution of the minority 3 He population ( 0 20 m -3 ). This stems from the high value of the peak RF power density absorbed by the minority species (ρ RF ∼ 60 MW/m 3 ) that should be obtained in Ignitor when the total injected power is about 18 MW. This experiment is suitable to begin the study of advanced fusion burning, because of the high plasma currents (I p 3 He fusion powers of the order of 1 MW should be attained. (author) 8 refs., 3 figs

  6. Experimental optimization of a direct injection homogeneous charge compression ignition gasoline engine using split injections with fully automated microgenetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Canakci, M. [Kocaeli Univ., Izmit (Turkey); Reitz, R.D. [Wisconsin Univ., Dept. of Mechanical Engineering, Madison, WI (United States)

    2003-03-01

    Homogeneous charge compression ignition (HCCI) is receiving attention as a new low-emission engine concept. Little is known about the optimal operating conditions for this engine operation mode. Combustion under homogeneous, low equivalence ratio conditions results in modest temperature combustion products, containing very low concentrations of NO{sub x} and particulate matter (PM) as well as providing high thermal efficiency. However, this combustion mode can produce higher HC and CO emissions than those of conventional engines. An electronically controlled Caterpillar single-cylinder oil test engine (SCOTE), originally designed for heavy-duty diesel applications, was converted to an HCCI direct injection (DI) gasoline engine. The engine features an electronically controlled low-pressure direct injection gasoline (DI-G) injector with a 60 deg spray angle that is capable of multiple injections. The use of double injection was explored for emission control and the engine was optimized using fully automated experiments and a microgenetic algorithm optimization code. The variables changed during the optimization include the intake air temperature, start of injection timing and the split injection parameters (per cent mass of fuel in each injection, dwell between the pulses). The engine performance and emissions were determined at 700 r/min with a constant fuel flowrate at 10 MPa fuel injection pressure. The results show that significant emissions reductions are possible with the use of optimal injection strategies. (Author)

  7. Monitoring a pilot CO2 injection experiment in a shallow aquifer using 3D cross-well electrical resistance tomography

    Science.gov (United States)

    Yang, X.; Lassen, R. N.; Looms, M. C.; Jensen, K. H.

    2014-12-01

    Three dimensional electrical resistance tomography (ERT) was used to monitor a pilot CO2 injection experiment at Vrøgum, Denmark. The purpose was to evaluate the effectiveness of the ERT method for monitoring the two opposing effects from gas-phase and dissolved CO2 in a shallow unconfined siliciclastic aquifer. Dissolved CO2 increases water electrical conductivity (EC) while gas phase CO2 reduce EC. We injected 45kg of CO2 into a shallow aquifer for 48 hours. ERT data were collected for 50 hours following CO2 injection. Four ERT monitoring boreholes were installed on a 5m by 5m square grid and each borehole had 24 electrodes at 0.5 m electrode spacing at depths from 1.5 m to 13 m. ERT data were inverted using a difference inversion algorithm for bulk EC. 3D ERT successfully detected the CO2 plume distribution and growth in the shallow aquifer. We found that the changes of bulk EC were dominantly positive following CO2 injection, indicating that the effect of dissolved CO2 overwhelmed that of gas phase CO2. The pre-injection baseline resistivity model clearly showed a three-layer structure of the site. The electrically more conductive glacial sand layer in the northeast region are likely more permeable than the overburden and underburden and CO2 plumes were actually confined in this layer. Temporal bulk EC increase from ERT agreed well with water EC and cross-borehole ground penetrating radar data. ERT monitoring offers a competitive advantage over water sampling and GPR methods because it provides 3D high-resolution temporal tomographic images of CO2 distribution and it can also be automated for unattended operation. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344. Lawrence Livermore National Security, LLC. LLNL IM release#: LLNL-PROC-657944.

  8. Optimization experiment of gas oil direct injection valve for CNG dual fuel diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.Y. [Chonnam National University Graduate School, Jeonju (Korea); Park, C. K. [Chonnam National University, Jeonju (Korea)

    1999-04-01

    In this study, we studied for a conversion from diesel engine to natural gas dual fuel engine. For this experimental, we tested about the injection quantity characteristics of pilot valve with the plunger diameter at the retraction volume and investigated to the engine performance and exhaust emissions with the nozzle hole number and injection nozzle diameter. As a result, when the plunger diameter is 7.5 mm at the retraction volume, 25 mm{sup 3}/st, the injection quantity characteristics develop. Also, when a nozzle type is 4*{phi} 0.24, total hydrocarbon(THC) emission reduce at low equivalence ratio. (author). 5 refs., 10 figs., 2 tabs.

  9. Stability of fault submitted to fluid injections

    Science.gov (United States)

    Brantut, N.; Passelegue, F. X.; Mitchell, T. M.

    2017-12-01

    Elevated pore pressure can lead to slip reactivation on pre-existing fractures and faults when the coulomb failure point is reached. From a static point of view, the reactivation of fault submitted to a background stress (τ0) is a function of the peak strength of the fault, i.e. the quasi-static effective friction coefficient (µeff). However, this theory is valid only when the entire fault is affected by fluid pressure, which is not the case in nature, and during human induced-seismicity. In this study, we present new results about the influence of the injection rate on the stability of faults. Experiments were conducted on a saw-cut sample of westerly granite. The experimental fault was 8 cm length. Injections were conducted through a 2 mm diameter hole reaching the fault surface. Experiments were conducted at four different order magnitudes fluid pressure injection rates (from 1 MPa/minute to 1 GPa/minute), in a fault system submitted to 50 and 100 MPa confining pressure. Our results show that the peak fluid pressure leading to slip depends on injection rate. The faster the injection rate, the larger the peak fluid pressure leading to instability. Wave velocity surveys across the fault highlighted that decreasing the injection-rate leads to an increase of size of the fluid pressure perturbation. Our result demonstrate that the stability of the fault is not only a function of the fluid pressure requires to reach the failure criterion, but is mainly a function of the ratio between the length of the fault affected by fluid pressure and the total fault length. In addition, we show that the slip rate increases with the background effective stress and with the intensity of the fluid pressure pertubation, i.e. with the excess shear stress acting on the part of the fault pertubated by fluid injection. Our results suggest that crustal fault can be reactivated by local high fluid overpressures. These results could explain the "large" magnitude human-induced earthquakes

  10. [Extracorporeal circulation and hypothermy surgery in tumors with vena cava extension: 20 years experience at the University Clinic of Navarra].

    Science.gov (United States)

    Rioja Zuazu, J; Rodríguez-Rubio Cortadillas, F; Zudaire Bergera, J J; Saiz Sansi, A; Rosell Costa, D; Robles García, J E; Rábago, G; Berián Polo, J M

    2008-04-01

    We present our 20 years experience treating patients with vena cava extension in whom an extracorporeal circulation, hypothermia, cardio circulatory arrest (ECC-H-CCA) in order to perform, together with a tumoral resection, a thrombus resection. From 1985 to 2005 a total of 28 retroperitoneal tumor were treated: 25 renal cancers, a Wilms tumor, a paratesticular rabdomiosarcoma, and a pheocromocitoma. All of them had an extension by means of thrombus above the suprahepatics veins. All of them were treated by means of ECC-H-CCA for thrombus extraction. A descriptive study of the serie is performed as well as a Kaplan Meyer survival study. Surgical complications were present within 10 patients (35%), with a surgical mortality of two patients (7%): one intra-operatively because a massive embolism of the lungs and the other because of a lung embolism on the 4th post-operative day. Global actuarial survival was 29.1+/-10% at three years and 17.5+/-8% at five years. Analyzing only who do not have metastatic lesions, nor lymph nodes at diagnosis their three year survival was 50.9+/-16.3% and 32.2+/-16% at five years. Mean while those who have any metastatic lesion at diagnosis their three and five years survival was 20.8+/-12% and 10.4+/-9% respectively. The employ of surgical techniques with ECC-H-CCA with in oncological pathology associated with vena cava thrombus is justified and its employment does not worsen the survival; it is indicated because its results, allowing a complete tumoral resection in a safe and reproducible fashion.

  11. Solid Organic Deposition During Gas Injection Studies

    DEFF Research Database (Denmark)

    Dandekar, Abhijit Y.; Andersen, Simon Ivar; Stenby, Erling Halfdan

    2000-01-01

    Recently a series of first contact miscibility (swelling) experiments have been performed on undersaturated light and heavy oils using LPG rich and methane rich injection gases, in which solid organic deposition was observed. A compositional gradient in the oils during the gas injection process....... The asphaltene content of the different oil samples were determined by the TP 143 method. The standard asphaltenes and the solid organic deposit recovered from the swelling tests were analyzed using FTIR, HPLC-SEC and H-1 NMR. The aim of these analyses is to reveal the molecular nature of the deposits formed...... during the gas injection process in comparison with the standard asphaltenes in order to understand the mechanisms involved in asphaltene deposition....

  12. Channeling experiment

    International Nuclear Information System (INIS)

    Abelin, H.; Birgersson, L.; Widen, H.; Aagren, T.; Moreno, L.; Neretnieks, I.

    1990-07-01

    Channeling of water flow and tracer transport in real fractures in a granite body at Stripa have been investigated experimentally. The experimental site was located 360 m below the ground level. Two kinds of experiments were performed. In the single hole experiments, 20 cm diameter holes were drilled about 2.5 m into the rock in the plane of the fracture. Specially designed packers were used to inject water into the fracture in 5 cm intervals all along the fracture trace in the hole. The variation of the injection flowrates along the fracture were used to determine the transmissivity variations in the fracture plane. Detailed photographs were taken from inside the hole and the visual fracture aperture was compared with the injection flowrates in the same locations. Geostatistical methods were used to evaluate the results. Five holes were measured in great detail. In addition 7 holes were drilled and scanned by simpler packer systems. A double hole experiment was performed where two parallel holes were drilled in the same fracture plane at nearly 2 m distance. Pressure pulse tests were made between the holes in both directions. Tracers were injected in 5 locations in one hole and monitored for in many locations in the other hole. The single hole experiment and the double hole experiment show that most of the fracture planes are tight but that there are open sections which form connected channels over distances of at least 2 meters. It was also found in the double hole experiment that the investigated fracture was intersected by at least one fracture between the two holes which diverted a large amount of the injected tracers to several distant locations at the tunnel wall. (authours)

  13. Experiment data report for semiscale Mod-1 Test S-01-5 (isothermal blowdown with core resistance simulator)

    International Nuclear Information System (INIS)

    Zender, S.N.; Crapo, H.S.; Jensen, M.F.; Sackett, K.E.

    1975-04-01

    Recorded test data are presented for Test S-01-5 of the semiscale Mod-1 isothermal blowdown test series. Test S-01-5 is one of several semiscale Mod-1 experiments which are counterparts of the LOFT nonnuclear experiments. System hardware is representative of LOFT with the design based on volumetric scaling methods and with initial conditions duplicating those identified for LOFT nonnuclear tests. Test S-01-5 was conducted with the secondary side of the steam generator pressurized with nitrogen gas in order to effectively eliminate heat transfer from the steam generator during blowdown and thereby to investigate the effect on overall system behavior of heat transfer from the steam generator. An orificed structure was used in the pressure vessel to simulate the LOFT core simulator. The test was initiated at isothermal conditions of 2270 psig and 540 0 F by a simulated offset shear of the cold leg broken loop piping. During system depressurization, coolant was injected into the cold leg of the operating loop to simulate emergency core cooling (ECC). Following the blowdown portion of the test, coolant spray was introduced into the pressure suppression tank to determine the response of the pressure suppression system. The uninterpreted data from Test S-01-5 and the reference material needed for future data analysis and test results reporting activities are presented. The data, presented in the form of graphs in engineering units, have been analyzed only to the extent necessary to assure that they are reasonable and consistent. (U.S.)

  14. Prediction of LOFT L1-4 experiment

    International Nuclear Information System (INIS)

    Soda, Kunihisa; Sasaki, Shinobu; Akimoto, Masayuki; Koizumi, Yasuo; Araya, Fumimasa

    1977-10-01

    LOFT L1-4 experimental results were predicted by LOFT Analysis Group and Code Development Group using RELAP-4J and ALARM-P1 respectively. The input data prepared by the former group were used in both the analyses. Thus any differences in the results should stem from the differences in code performance characteristics of the two codes. (1) The coolant behaviors predicted by RELAP-4J and ALARM-P1 are in good agreement although some differences do exist between these two calculation models. (2) Large difference is seen in coolant flow rate across the pump. The coast down and the flow rate by ALARM-P1 are larger and smaller respectively than by RELAP-4J. (3) An explicit method of the ALARM-P1 leads to unstable calculation at a T shaped junction when one of the two volumes connected by the junction is filled with subcooled water. (4) Coolant flow in the downcomer, heat transfer to and from the steam generator secondary and suppression tank behavior must be modified to better predict the experimental results. (5) Additional instrumentation in reflood assist and ECC injection lines are necessary to better nderstand the coolant behavior. (auth.)

  15. Experimental observation of a multi-dimensional mixing behavior of steam-water flow in the MIDAS test facility

    International Nuclear Information System (INIS)

    Kweon, T. S.; Yun, B. J.; Ah, D. J.; Ju, I. C.; Song, C. H.; Park, J. K.

    2001-01-01

    Multi-dimensional thermal-hydraulic hehavior, such as ECC (Emergency Core Cooling) bypass, ECC penetration, steam-water condensation and accumulated water level, in an annular downcomer of a PWR (Pressurized Water Reactor) reactor vessel with a DVI(Direct Vessel Injection) injection mode is presented based on the experimental observations in the MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) steam-water facility. From the steady-state tests to similate a late reflood phase of LBLOCA (Large Break Loss-of-Coolant Accidents), major thermal-hydraulic phenomena in the downcomer are quantified under a wide range of test conditions. Especially, isothermal lines show well multi-dimensional phenomena of phase interaction between steam and water in the annulus downcomer. Overall test results show that multi-dimensional thermal-hydraulic behaviors occur in the downcomer annulus region as expected. The MIDAS test facility is a steam-water separate effect test facility, which is 1/4.93 linearly scaled-down of a 1400 MWe PWR type of nuclear reactor, with focusing on understanding multi-dimensional thermal-hydraulic phenomena in annulus downcomer with various types of safety injection location during refill or reflood phase of a LBLOCA in PWR

  16. Modelling of Pesticide Transport During An Injection Experiment In A Physical and Geochemical Heterogeneous Aquifer

    Science.gov (United States)

    Hojberg, A. L.; Engesgaard, P.; Bjerg, P. L.

    The fate of selected pesticides under natural groundwater conditions was studied by natural gradient short and long term injection experiments in a shallow uncon- fined aerobic aquifer. Bentazone, DNOC, MCPP, dichlorprop, isoproturon, and BAM (dichlobenil metabolite) were injected in aqueous solution with bromide as a nonre- active tracer. The Bromide and pesticide plumes were sampled during the initial 25 m of migration in a dense monitoring net of multilevel samplers. The aquifer was physical and geochemical heterogeneous, which affected transport of several of the pesticides. A 3D reactive transport code was developed including one- and two-site linear/nonlinear equilibrium/nonequilibrium sorption and first-order as well as single Monod degradation kinetic coupled to microbial growth. Model simulations demon- strated that microbial growth was likely supported by the phenoxy acids MCPP and dichlorprop, while degradation of DNOC was adequately described by first-order degradation with no initial lag time. An observed vertical increase in pH was observed at the site and implemented in the transport code. The numerical analysis indicated that degradation of the three degradable pesticides may have been affected by vertical pH variations. Spatial variability in observed DNOC sorption was similarly suspected to be an effect of varying pH. pH dependency on DNOC sorption was confirmed by the model recognized by a match to observed breakthrough at the individual sampling points, when pH variation was included in the simulations.

  17. First observations of acceleration of injected electrons in a laser plasma beatwave experiment

    International Nuclear Information System (INIS)

    Ebrahim, N.A.; Martin, F.; Bordeur, P.; Heighway, E.A.; Matte, J.P.; Pepin, H.; Lavigne, P.

    1986-01-01

    The first experimental observations of acceleration of injected electrons in a laser driven plasma beatwave are presented. The plasma waves were excited in an ionized gas jet, using a short pulse high intensity CO 2 laser with two collinearly propagating beams (at λ = 9.6 μm and 10.6 μm) to excite a fast wave (v/sub p/ = c). The source of electrons was a laser plasma produced on an aluminum slab target by a third, synchronized CO 2 laser beam. A double-focusing dipole magnet was used to energy select and inject electrons into the beatwave, and a second magnetic spectrograph was used to analyze the accelerated electrons. Electron acceleration was only observed when the appropriate resonant plasma density was produced (∼ 10 17 cm -3 ), the two laser lines were incident on the plasma, and electrons were injected into this plasma from an external source

  18. Hot carrier injection degradation under dynamic stress

    International Nuclear Information System (INIS)

    Ma Xiao-Hua; Cao Yan-Rong; Hao Yue; Zhang Yue

    2011-01-01

    In this paper, we have studied hot carrier injection (HCI) under alternant stress. Under different stress modes, different degradations are obtained from the experiment results. The different alternate stresses can reduce or enhance the HC effect, which mainly depends on the latter condition of the stress cycle. In the stress mode A (DC stress with electron injection), the degradation keeps increasing. In the stress modes B (DC stress and then stress with the smallest gate injection) and C (DC stress and then stress with hole injection under V g = 0 V and V d = 1.8 V), recovery appears in the second stress period. And in the stress mode D (DC stress and then stress with hole injection under V g = −1.8 V and V d = 1.8 V), as the traps filled in by holes can be smaller or greater than the generated interface states, the continued degradation or recovery in different stress periods can be obtained. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  19. Visible Spectrometer at the Compact Toroid Injection Experiment, the Sustained Spheromak Plasma Experiment and the Alcator C-Mod Tokamak for Doppler Width and Shift Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Graf, A; Howard, S; Horton, R; Hwang, D; May, M; Beiersdorfer, P; McLean, H; Terry, J

    2006-05-15

    A novel Doppler spectrometer is currently being used for ion or neutral velocity and temperature measurements on the Alcator C-Mod Tokamak. The spectrometer has an f/No. of {approx}3.1 and is appropriate for visible light (3500-6700 {angstrom}). The full width at half maximum from a line emitting calibration source has been measured to be as small as 0.4 {angstrom}. The ultimate time resolution is line brightness light limited and on the order of ms. A new photon efficient detector is being used for the setup at C-Mod. Time resolution is achieved by moving the camera during a plasma discharge in a perpendicular direction through the dispersion plane of the spectrometer causing a vertical streaking across the camera face. Initial results from C-Mod as well as previous measurements from the Compact Toroid Injection Experiment (CTIX) and the Sustained Spheromak Plasma Experiment (SSPX) are presented.

  20. LHC Injection Beam Quality During LHC Run I

    CERN Document Server

    AUTHOR|(CDS)2079186; Kain, Verena; Stapnes, Steinar

    The LHC at CERN was designed to accelerate proton beams from 450 GeV to 7 TeV and collide them in four large experiments. The 450 GeV beam is extracted from the last pre-accelerator, the SPS, and injected into the LHC via two 3 km long transfer lines, TI 2 and TI 8. The injection process is critical in terms of preservation of beam quality and machine protection. During LHC Run I (2009-2013) the LHC was filled with twelve high intensity injections per ring, in batches of up to 144 bunches of 1.7*10^11 protons per bunch. The stored beam energy of such a batch is already an order of magnitude above the damage level of accelerator equipment. Strict quality and machine protection requirements at injection have a significant impact on operational efficiency. During the first years of LHC operation, the injection phase was identified as one of the limiting factors for fast LHC turnaround time. The LHC Injection Quality Check (IQC) software framework was developed as a part of this thesis to monitor the beam quality...

  1. Construction and characterization of valve for fast gas injection

    International Nuclear Information System (INIS)

    Ueda, M.; Rossi, J.O.; Aso, Y.; Mangueira, L.S.; Pereira, C.A.

    1989-01-01

    An electromagnetic valve for fast gas injection was built and characterized. This type of gas injection valve has been routinely applied to various plasma experiments: in magnetic confinement devices as TOKAMAK, RFP and Compact Toroids as well as intense ion beam and neutral particle generators. The valve is capable of injecting gas pulses with up to 80 m Torr peak pressure, rising time < 400 μs and duration time of 40 ms, in the present experimental set-up. It is easy to build and its components can be totally acquired in the country. (author)

  2. ATHLET calculations of the pressurizer surge line break (PH-SLB test) at the PMK-2 test facility

    International Nuclear Information System (INIS)

    Krepper, E.; Schaefer, F.

    2000-01-01

    At the Hungarian integral test facility PMK-2 a pressurizer surge line break experiment (PH-SLB test) was carried out with the PHARE 4.2.6b project. The primary objective of the test was to provide experimental data for a surge line break transient at VVER-440 reactors with reduced injection from the emergency core cooling systems (ECC). At the Institute of Safety Research calculations of the experiment were performed with the thermohydraulic computer code ATHLET, which was developed by GRS (Gesellschaft fuer Anlagen- und Reaktorsicherheit) mbH. In the context of the PHARE 4.2.6b project the Institute of Safety Research has also supplied the void fraction measurement system for the PMK-2 test facility and was involved in the evaluation of the experimental results. (orig.)

  3. Research on Continuous Injection Direct Rolling Process for PMMA Optical Plate

    Directory of Open Access Journals (Sweden)

    HaiXiong Wang

    2014-06-01

    Full Text Available Continuous injection direct rolling (CIDR combined intermittent injection and rolling process is a new technology for molding optical polymer plates with microstructured patterns; research on forming PMMA optical plates is an aspect of it in this paper. The equipment of CIDR process consists of plastic injection module, precision rolling module, and automatic coiling module. Based on the establishing mathematical CIDR models, numerical analysis was used to explode the distribution of velocity, temperature, and pressure in injection-rolling zone. The simulation results show that it is feasible to control the temperature, velocity, and injection-rolling force, so it can form polymer plate under certain process condition. CIDR experiment equipment has been designed and produced. PMMA optical plate was obtained by CIDR experiments, longitudinal thickness difference is 0.005 mm/200 mm, horizontal thickness difference is 0.02/200 mm, transmittance is 86.3%, Haze is 0.61%, and the difference is little compared with optical glasses. So it can be confirmed that CIDR process is practical to produce PMMA optical plates.

  4. Simulation of multi-pulse coaxial helicity injection in the Sustained Spheromak Physics Experiment

    Science.gov (United States)

    O'Bryan, J. B.; Romero-Talamás, C. A.; Woodruff, S.

    2018-03-01

    Nonlinear, numerical computation with the NIMROD code is used to explore magnetic self-organization during multi-pulse coaxial helicity injection in the Sustained Spheromak Physics eXperiment. We describe multiple distinct phases of spheromak evolution, starting from vacuum magnetic fields and the formation of the initial magnetic flux bubble through multiple refluxing pulses and the eventual onset of the column mode instability. Experimental and computational magnetic diagnostics agree on the onset of the column mode instability, which first occurs during the second refluxing pulse of the simulated discharge. Our computations also reproduce the injector voltage traces, despite only specifying the injector current and not explicitly modeling the external capacitor bank circuit. The computations demonstrate that global magnetic evolution is fairly robust to different transport models and, therefore, that a single fluid-temperature model is sufficient for a broader, qualitative assessment of spheromak performance. Although discharges with similar traces of normalized injector current produce similar global spheromak evolution, details of the current distribution during the column mode instability impact the relative degree of poloidal flux amplification and magnetic helicity content.

  5. Phase III clinical evaluation of gadoteridol injection: Experience in pediatric neuro-oncologic MR imaging

    International Nuclear Information System (INIS)

    Debatin, J.F.; Nadel, S.N.; Gray, L.; Trotter, P.; Friedman, H.S.; Hockenberger, B.; Oakes, W.J.

    1992-01-01

    Twenty-two pediatric patients with known CNS neoplasms underwent magnetic resonance (MR) imaging before and after intravenous injection of 0.1 mmol/kg gadoteridol injection as part of a Phase IIIB open label multicenter clinical trial. Intravenous adminstration of this neutral, nonionic contrast agent was found to be safe in children. No clinically relevant changes in vital signs or laboratory values were attributed to the administration of gadoteridol injection. There were no systemic complaints. The imaging characteristics of gadoteridol in pediatric CNS disease appeared similar to those of gadopentetate dimeglumine. The very low toxicity, inherent to this nonionic low osmolal paramagnetic contrast formulation may allow administration of increased doses at increased infusion rates for an increased number of indications with improved sensitivity. (orig.)

  6. Improving safety margin of LWRs by rethinking the emergency core cooling system criteria and safety system capacity

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youho, E-mail: euo@kaist.ac.kr; Kim, Bokyung, E-mail: bkkim2@kaist.ac.kr; NO, Hee Cheon, E-mail: hcno@kaist.ac.kr

    2016-10-15

    Highlights: • Zircaloy embrittlement criteria can increase to 1370 °C for CP-ECR lower than 13%. • The draft ECCS criteria of U.S. NRC allow less than 5% in power margin. • The Japanese fracture-based criteria allow around 5% in power margin. • Increasing SIT inventory is effective in assuring safety margin for power uprates. - Abstract: This study investigates the engineering compatibility between emergency core cooling system criteria and safety water injection systems, in the pursuit of safety margin increase of light water reactors. This study proposes an acceptable temperature increase to 1370 °C as long as equivalent cladding reacted calculated by the Cathcart–Pawel equation is below 13%, after an extensive literature review. The influence of different ECCS criteria on the safety margin during large break loss of coolant accident is investigated for OPR-1000 by the system code MARS-KS, implemented with the KINS-REM method. The fracture-based emergency core cooling system (ECCS) criteria proposed in this study are shown to enable power margins up to 10%. In the meantime, the draft U.S. NRC’s embrittlement criteria (burnup-sensitive) and Japanese fracture-based criteria are shown to allow less than 5%, and around 5% of power margins, respectively. Increasing safety injection tank (SIT) water inventory is the key, yet convenient, way of assuring safety margin for power increase. More than 20% increase in the SIT water inventory is required to allow 15% power margins, for the U.S. NRC’s burnup-dependent embrittlement criteria. Controlling SIT water inventory would be a useful option that could allow the industrial desire to pursue power margins even under the recent atmosphere of imposing stricter ECCS criteria for the considerable burnup effects.

  7. Neutral beam injection on the PLT tokamak

    International Nuclear Information System (INIS)

    Schilling, G.; Ashcroft, D.L.; Eubank, H.P.; Grisham, L.R.; Knauer, R.C.; Stewart, L.D.; Stooksberry, R.W.; Ulrickson, M.; Williams, M.D.

    1981-01-01

    We describe the operation of the neutral beam injection system on the PLT tokamak. Improvements, retrofits, and conditioning have changed the injection system from an experiment in itself to a fairly reliable and useful plasma heating tool. We will present a brief overview of our physics achievements and then describe the system as it exists now. This will include injector performance, conditioning needs, maintenance needs, reliability, and daily operating sequences. We will also include hardware modifications and additions, electrical and mechanical, and point out remaining problem areas

  8. Disruption mitigation with high-pressure helium gas injection on EAST tokamak

    Science.gov (United States)

    Chen, D. L.; Shen, B.; Granetz, R. S.; Qian, J. P.; Zhuang, H. D.; Zeng, L.; Duan, Y.; Shi, T.; Wang, H.; Sun, Y.; Xiao, B. J.

    2018-03-01

    High pressure noble gas injection is a promising technique to mitigate the effect of disruptions in tokamaks. In this paper, results of mitigation experiments with low-Z massive gas injection (helium) on the EAST tokamak are reported. A fast valve has been developed and successfully implemented on EAST, with valve response time  ⩽150 μs, capable of injecting up to 7 × 1022 particles, corresponding to 300 times the plasma inventory. Different amounts of helium gas were injected into stable plasmas in the preliminary experiments. It is seen that a small amount of helium gas (N_He≃ N_plasma ) can not terminate a discharge, but can trigger MHD activity. Injection of 40 times the plasma inventory impurity (N_He≃ 40× N_plasma ) can effectively radiate away part of the thermal energy and make the electron density increase rapidly. The mitigation result is that the current quench time and vertical displacement can both be reduced significantly, without resulting in significantly higher loop voltage. This also reduces the risk of runaway electron generation. As the amount of injected impurity gas increases, the gas penetration time decreases slowly and asymptotes to (˜7 ms). In addition, the impurity gas jet has also been injected into VDEs, which are more challenging to mitigate that stable plasmas.

  9. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego.

    Science.gov (United States)

    Wood, Emily F; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Cuevas Mota, Jazmine; Garfein, Richard S; Strathdee, Steffanie A; Wagner, Karla D

    2017-03-01

    powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego

    Science.gov (United States)

    Wood, Emily F.; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Mota, Jazmine Cuevas; Garfein, Richard S.; Strathdee, Steffanie A.; Wagner, Karla D.

    2017-01-01

    feelings of stress, anxiety, and powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Conclusion Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. PMID:28111221

  11. Magnetic detection of ferrofluid injection zones

    Energy Technology Data Exchange (ETDEWEB)

    Borglin, S.; Moridis, G.; Becker, A.

    1998-03-01

    Ferrofluids are stable colloidal suspensions of magnetic particles that can be stabilized in various carrier liquids. In this study the authors investigate the potential of ferrofluids to trace the movement and position of liquids injected in the subsurface using geophysical methods. An ability to track and monitor the movement and position of injected liquids is essential in assessing the effectiveness of the delivery system and the success of the process. Ferrofluids can also provide a significant detection and verification tool in containment technologies, where they can be injected with the barrier liquids to provide a strong signature allowing determination of the barrier geometry, extent, continuity and integrity. Finally, ferrofluids may have unique properties as tracers for detecting preferential flow features (such as fractures) in the subsurface, and thus allow the design of more effective remediation systems. In this report the authors review the results of the investigation of the potential of ferrofluids to trace the movement and position of liquids injected in the subsurface using geophysical methods. They demonstrate the feasibility of using conventional magnetometry for detecting subsurface zones of injected ferrofluids used to trace liquids injected for remediation or barrier formation. The geometrical shapes considered were a sphere, a thin disk, a rectangular horizontal slab, and a cylinder. Simple calculations based on the principles of magnetometry are made to determine the detection depths of FTs. Experiments involving spherical, cylindrical and horizontal slabs show a very good agreement between predictions and measurements.

  12. Classical description of the electron capture to the continuum cusp formation in ion-atom collisions

    International Nuclear Information System (INIS)

    Illescas, Clara; Pons, B.; Riera, A.

    2002-01-01

    Classical calculations are used to describe the dynamics of the electron capture to the continuum (ECC) cusp formation in H + +He collisions. We illustrate the frontier character of the ECC electrons between capture and ionization, and confirm that it is a temporary capture, through projectile focusing, that is responsible for the ECC cusp. Furthermore, the cusp is not a divergence smoothed by the experiment, and is slightly shifted from the impact-velocity value because of the residual pull from the target after ionization. This shift is larger the smaller the nuclear velocity

  13. Spin injection into a two-dimensional electron gas using inter-digital-ferromagnetic contacts

    DEFF Research Database (Denmark)

    Hu, C.M.; Nitta, J.; Jensen, Ane

    2002-01-01

    We present a model that describes the spin injection across a single interface with two electrodes. The spin-injection rate across a typical hybrid junction made of ferromagnet (FM) and a two-dimensional electron gas (2DEG) is found at the percentage level. We perforin spin-injection-detection ex......-injection-detection experiment on devices with two ferromagnetic contacts on a 2DEG confined in an InAs quantum well. A spin-injection rate of 4.5% is estimated from the measured magnetoresistance....

  14. Twenty-third water reactor safety information meeting. Volume 3, structural and seismic engineering, primary systems integrity, equipment operability and aging, ECCS strainer blockage research and regulatory issues

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 3, presents topics in Structural & Seismic Engineering, Primary Systems Integrity, Equipment Operability and Aging, and ECCS Strainer Blockage Research & Regulatory Issues. Individual papers have been cataloged separately.

  15. Twenty-third water reactor safety information meeting. Volume 3, structural and seismic engineering, primary systems integrity, equipment operability and aging, ECCS strainer blockage research and regulatory issues

    International Nuclear Information System (INIS)

    Monteleone, S.

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 3, presents topics in Structural ampersand Seismic Engineering, Primary Systems Integrity, Equipment Operability and Aging, and ECCS Strainer Blockage Research ampersand Regulatory Issues. Individual papers have been cataloged separately

  16. Modeling and Experiments on Injection into University of Maryland Electron Ring

    International Nuclear Information System (INIS)

    Bai, G.; Kishek, R. A.; Beaudoin, B.; Bernal, S.; Feldman, D.; Godlove, T.; Haber, I.; Quinn, B.; Reiser, M.; Sutter, D.; Walter, M.; O'Shea, P. G.

    2006-01-01

    The University of Maryland Electron Ring (UMER) is built as a low-cost testbed for intense beam physics for benefit of larger ion accelerators. The beam intensity is designed to be variable, spanning the entire range from low current operation to highly space-charge-dominated transport. The ring has been closed and multi-turn commissioning has begun. One of the biggest challenges of multi-turn operation of UMER is correctly operating the Y-shaped injection/recirculation section, which is specially designed for UMER multi-turn operation. It is a challenge because the system requires several quadrupoles and dipoles in a very stringent space, resulting in mechanical, electrical, and beam control complexities. Also, the Earth's magnetic field and the image charge effects have to be investigated because they are strong enough to impact the beam centroid motion. This paper presents both simulation and experimental study of the beam centroid motion in the injection region to address above issues

  17. US-guided percutaneous ethanol injection in Plummer's adenoma

    International Nuclear Information System (INIS)

    Lagalla, R.; Iovane, A.; Caruso, G.; Midiri, N.; Oliveri, D.; Brancato, G.; Cardinale, A.

    1991-01-01

    The authors report their experience in the study of 8 patients showing sympoms of thyroid hyperfunction (Plummer's adenoma) and treated with US-guided percutaneous ethanol injection. The treatment consisted in injecting sterile ethanol in varying amounts (2 to 5 ml) according to nodule size, using a fine needle under US guidance. The patients underwent 3 to 6 injections, according to biochemical (T3-T4-TSH) and scintigraphic findings. Follow-up ay 12 months showed regression of clinical symptoms, a trend of hormone levels toward normalization and recovery of previously suppressed parenchymal function. No significant complications were observed, except for a transient thyrotoxic crisis in the patient bearing the largest nodule. The treatment of Plummer's adenoma by means of percutaneous ethanol injection under us guidance appears to provide specific clinical and technical advantages over other conventional treatments

  18. ROSA-II test data report, 13

    International Nuclear Information System (INIS)

    1978-07-01

    Results of the ROSA-II test simulating a loss-of-coolant accident (LOCA) in a PWR are presented, including test conditions and interpretations of phenomena observed in test runs 502, 505, 506 and 507. Development tests were performed to find a more effective ECCS injection method than the existing one based on cold leg injection. A combined injection of hot water into upper plenum in early stage of blowdown and subsequent cold water into lower plenum is the most effective method for a cold leg break. A hot leg injection of a low pressure injection system is effective for direct core cooling and early reflooding. The generalization for actual reactors will require analyses with a reliable code. (auth.)

  19. Sexual Behaviors, Experiences of Sexual Violence, and Substance Use among Women Who inject Drugs: Accessing Health and Prevention Services in Puerto Rico.

    Science.gov (United States)

    Collazo-Vargas, Erika M; Dodge, Brian; Herbenick, Debby; Guerra-Reyes, Lucia; Mowatt, Rasul; Otero-Cruz, Ilia M; Rodríguez-Díaz, Carlos

    2018-06-01

    People who inject drugs (PWID) face numerous gender-specific health risks, which increase their susceptibility to adverse outcomes, including violence. There is a need for research on female PWID to capture their unique experiences and understand behavioral and gender-based differences. This study aimed to understand which drug use and sexual behaviors are the most prevalent among female PWID accessing health services in Puerto Rico and to gather preliminary information on those individuals' experiences of sexual violence. Utilizing a transformative theoretical perspective, a mixed-methods study was conducted with a sample of 90 Puerto Rican women who reported recent (past 12 months) injection drug use (IDU) This manuscript focused on Phase 1, in which participants completed an interviewer-administered survey eliciting information about sexual behaviors, drug use, experiences of sexual violence, and access to healthcare services. Phase 2 involved an in-depth interview focused on sexual health and access to healthcare services. Female PWID were found to engage in a variety of sexual behaviors throughout their lifespans and at their most recent sexual events. There were significant differences across age groups for participants, those being time of most recent sexual event (p = 0.007), partner's sex (p = 0.039), relationship with partner (p = 0.023), contraception method used (p = 0.057), and reports of partner orgasm (p = 0.055). Over half of all participants reported having experienced sexual violence in their lifetime. This study extends the literature on PWID in Puerto Rico by underscoring the diversity of female PWID sexual experiences and needs while illustrating how those experiences are often mediated by drug use. The findings highlight the need for further research on female PWID in Puerto Rico to better develop programs that include sexual violence prevention as part of future interventions for this population.

  20. Initial operation and performance of the PDX neutral-beam injection system

    International Nuclear Information System (INIS)

    Kugel, H.W.; Eubank, H.P.; Kozub, T.A.; Rossmassler, J.E.; Schilling, G.; van Halle, A.; Williams, M.D.

    1982-01-01

    In 1981, the joint ORNL/PPPL PDX neutral beam heating project succeeded in reliably injecting 7.2 MW of D 0 into the PDX plasma, at nearly perpendicular angles, and achieved ion temperatures up to 6.5 keV. The expeditious achievement of this result was due to the thorough conditioning and qualification of the PDX neutral beam ion sources at ORNL prior to delivery coupled with several field design changes and improvements in the injection system made at PPPL as a result of neutral beam operating experience with the PLT tokamak. It has been found that the operation of high power neutral beam injection systems in a tokamak-neutral beam environment requires procedures and performance different from those required for development operation on test stands. In this paper, we review the installatin of the PDX neutral beam injection system, and its operation and performance during the initial high power plasma heating experiments with the PDX tokamak

  1. Experimental demonstration of tokamak inductive flux saving by transient coaxial helicity injection on national spherical torus experiment

    Energy Technology Data Exchange (ETDEWEB)

    Raman, R.; Jarboe, T. R.; Nelson, B. A. [University of Washington, Seattle, Washington 98195 (United States); Mueller, D.; Bell, M. G.; Gerhardt, S.; LeBlanc, B.; Menard, J.; Ono, M.; Roquemore, L. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Soukhanovskii, V. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2011-09-15

    Discharges initiated by transient coaxial helicity injection in National Spherical Torus Experiment have attained peak toroidal plasma currents up to 300 kA. When induction from the central solenoid is then applied, these discharges develop up to 300 kA additional current compared to discharges initiated by induction only. CHI initiated discharges in NSTX have achieved 1 MA of plasma current using only 258 mWb of solenoid flux whereas standard induction-only discharges require about 50% more solenoid flux to reach 1 MA. In addition, the CHI-initiated discharge has lower plasma density and a low normalized internal plasma inductance of 0.35, as needed for achieving advanced scenarios in NSTX.

  2. Development of Metal/Polymer Mixtures Dedicated to Macro and Micro powder Injection Moulding : Experiments and Simulations

    International Nuclear Information System (INIS)

    Quinard, C.; Barriere, T.; Gelin, J. C.; Song, J. P.; Cheng, Z. Q.; Liu, B. S.

    2007-01-01

    Important research tasks at ENSMM/LMA are concerned for the development of mixtures of fine powders associated to polymer binders dedicated to the powder injection moulding (PIM) and to the powder injection micro-moulding (μPIM) in accordance with many works already carried out with different feedstock suppliers dedicated to the macro-components. These research tasks are completed with the simulations of injection and sintering for solid state diffusion for to validate the mumerical models

  3. Risk-Informed Margin Management (RIMM) Industry Applications IA1 - Integrated Cladding ECCS/LOCA Performance Analysis - Problem Statement

    Energy Technology Data Exchange (ETDEWEB)

    Szilard, Ronaldo Henriques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Youngblood, Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Frepoli, Cesare [Idaho National Lab. (INL), Idaho Falls, ID (United States); Yurko, Joseph P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swindlehurst, Gregg [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Smith, Curtis L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-04-01

    The U. S. NRC is currently proposing rulemaking designated as “10 CFR 50.46c” to revise the LOCA/ECCS acceptance criteria to include the effects of higher burnup on cladding performance as well as to address some other issues. The NRC is also currently resolving the public comments with the final rule expected to be issued in the summer of 2016. The impact of the final 50.46c rule on the industry will involve updating of fuel vendor LOCA evaluation models, NRC review and approval, and licensee submittal of new LOCA evaluations or reanalyses and associated technical specification revisions for NRC review and approval. The rule implementation process, both industry and NRC activities, is expected to take 5-10 years following the rule effective date. The need to use advanced cladding designs is expected. A loss of operational margin will result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin.

  4. Non-injection Drug Use and Injection Initiation Assistance among People Who Inject Drugs in Tijuana, Mexico.

    Science.gov (United States)

    Ben Hamida, Amen; Rafful, Claudia; Jain, Sonia; Sun, Shelly; Gonzalez-Zuniga, Patricia; Rangel, Gudelia; Strathdee, Steffanie A; Werb, Dan

    2018-02-01

    Although most people who inject drugs (PWID) report receiving assistance during injection initiation events, little research has focused on risk factors among PWID for providing injection initiation assistance. We therefore sought to determine the influence of non-injection drug use among PWID on their risk to initiate others. We used generalized estimating equation (GEE) models on longitudinal data among a prospective cohort of PWID in Tijuana, Mexico (Proyecto El Cuete IV), while controlling for potential confounders. At baseline, 534 participants provided data on injection initiation assistance. Overall, 14% reported ever initiating others, with 4% reporting this behavior recently (i.e., in the past 6 months). In a multivariable GEE model, recent non-injection drug use was independently associated with providing injection initiation assistance (adjusted odds ratio [AOR] = 2.42, 95% confidence interval [CI] = 1.39-4.20). Further, in subanalyses examining specific drug types, recent non-injection use of cocaine (AOR = 9.31, 95% CI = 3.98-21.78), heroin (AOR = 4.00, 95% CI = 1.88-8.54), and methamphetamine (AOR = 2.03, 95% CI = 1.16-3.55) were all significantly associated with reporting providing injection initiation assistance. Our findings may have important implications for the development of interventional approaches to reduce injection initiation and related harms. Further research is needed to validate findings and inform future approaches to preventing entry into drug injecting.

  5. [Steam and air co-injection in removing TCE in 2D-sand box].

    Science.gov (United States)

    Wang, Ning; Peng, Sheng; Chen, Jia-Jun

    2014-07-01

    Steam and air co-injection is a newly developed and promising soil remediation technique for non-aqueous phase liquids (NAPLs) in vadose zone. In this study, in order to investigate the mechanism of the remediation process, trichloroethylene (TCE) removal using steam and air co-injection was carried out in a 2-dimensional sandbox with different layered sand structures. The results showed that co-injection perfectly improved the "tailing" effect compared to soil vapor extraction (SVE), and the remediation process of steam and air co-injection could be divided into SVE stage, steam strengthening stage and heat penetration stage. Removal ratio of the experiment with scattered contaminant area was higher and removal speed was faster. The removal ratios from the two experiments were 93.5% and 88.2%, and the removal periods were 83.9 min and 90.6 min, respectively. Steam strengthened the heat penetration stage. The temperature transition region was wider in the scattered NAPLs distribution experiment, which reduced the accumulation of TCE. Slight downward movement of TCE was observed in the experiment with TCE initially distributed in a fine sand zone. And such downward movement of TCE reduced the TCE removal ratio.

  6. Interpretation and modeling of a subsurface injection test, 200 East Area, Hanford, Washington

    International Nuclear Information System (INIS)

    Smoot, J.L.; Lu, A.H.

    1994-11-01

    A tracer experiment was conducted in 1980 and 1981 in the unsaturated zone in the southeast portion of the Hanford 200 East Area near the Plutonium-Uranium Extraction (PUREX) facility. The field design consisted of a central injection well with 32 monitoring wells within an 8-m radius. Water containing radioactive and other tracers was injected weekly during the experiment. The unique features of the experiment were the documented control of the inputs, the experiment's three-dimensional nature, the in-situ measurement of radioactive tracers, and the use of multiple injections. The spacing of the test wells provided reasonable lag distribution for spatial correlation analysis. Preliminary analyses indicated spatial correlation on the order of 400 to 500 cm in the vertical direction. Previous researchers found that two-dimensional axisymmetric modeling of moisture content generally underpredicts lateral spreading and overpredicts vertical movement of the injected water. Incorporation of anisotropic hydraulic properties resulted in the best model predictions. Three-dimensional modeling incorporated the geologic heterogeneity of discontinuous layers and lenses of sediment apparent in the site geology. Model results were compared statistically with measured experimental data and indicate reasonably good agreement with vertical and lateral field moisture distributions

  7. Process Condition Monitoring of Micro Moulding Using a Two-plunger Micro Injection Moulding Machine

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Guerrier, Patrick

    2010-01-01

    The influence of micro injection moulding (µIM) process parameters (melt and mould temperature, piston injection speed and stoke length) on the injection pressure was investigated using Design of Experiments. Direct piston injection pressure measurements were performed and data collected using...... a micro injection moulding machine equipped with a two-pluger injection unit. Miniaturized dog-bone shaped speciments on polyoxymethylene (POM) were moulded over a wide range of processing cpnditions in order to characterize the process and assess its capability. Experimental results obtained under...

  8. Low energy, high power injection in JT-60 NBI

    International Nuclear Information System (INIS)

    Mizuno, Makoto; Dairaku, Masayuki; Horiike, Hiroshi

    1988-05-01

    JT-60 neutral beam injector (JT-60 NBI) is designed to inject 20 MW neutral hydrogen beam at energies of 70 ∼ 100 keV and the injection power decreases significantly at low energies (∼40 keV). For the extention of operation region aiming at the low density plasma heating and achieving H-mode by plasma periphery heating, increment of the injection power at low beam energies was required. The single-stage acceleration system was investigated in advance at the Prototype Injector Unit. From this result, the total injection power of 17 MW at 40 keV, 48 A per source was expected at the JT-60 NBI. This system was adopted in the JT-60 NBI from June, 1987 to July, 1987 and 17.6 MW neutral beam injection power was achieved. In the NB heating experiment, the H-mode transition phenomena was observed in JT-60 plasma. (author)

  9. Self-injection threshold in self-guided laser wakefield accelerators

    Directory of Open Access Journals (Sweden)

    S. P. D. Mangles

    2012-01-01

    Full Text Available A laser pulse traveling through a plasma can excite large amplitude plasma waves that can be used to accelerate relativistic electron beams in a very short distance—a technique called laser wakefield acceleration. Many wakefield acceleration experiments rely on the process of wave breaking, or self-injection, to inject electrons into the wave, while other injection techniques rely on operation without self-injection. We present an experimental study into the parameters, including the pulse energy, focal spot quality, and pulse power, that determine whether or not a wakefield accelerator will self-inject. By taking into account the processes of self-focusing and pulse compression we are able to extend a previously described theoretical model, where the minimum bubble size k_{p}r_{b} required for trapping is not constant but varies slowly with density and find excellent agreement with this model.

  10. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  11. Experimental research of percutaneous intrahepatic ethanol injection under CT guidance

    International Nuclear Information System (INIS)

    Kang Deqiang; Tian Jianming; Xiang Cheng; Zhang Feng; Zuo Changjing; Zang Tingzhen; Shi Lijing; Yuan Xiaodong; Tian Yuan; Li Shijian

    2005-01-01

    Objective: To study percutaneous ethanol injection caused liver injures on rabbits with different doses, concentrations and temperatures. Methods: The experiment was carried out in 54 New Zealand rabbits under randomized dividing groups with the purpose of observing the microscopic pathologic changes after 1 day, 1 week, 2 weeks of ethanol injection and the blood sampling biochemical with imaging changes, 1, 3, 7, 10, 14 days before and after injection. Results: Both total ethanol dose and concentration can cause different size of necrosis on rabbits liver tissue with the interactions between them. Pathologic changes in rabbits liver appeared to be typical coagulative necrosis. The injuries causes by ethanol injection were transient and repairable after a short period. Conclusions: Percutaneous ethanol injection causes mild injures to the liver. The method is safe and practicable. (authors)

  12. COMBUSTION ANALYSIS OF A CNG DIRECT INJECTION SPARK IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    A. Rashid A. Aziz

    2010-12-01

    Full Text Available An experimental study was carried out on a dedicated compressed natural gas direct injection (CNG-DI engine with a compression ratio (CR of 14 and a central injection system. Several injection timing parameters from early injection timing (300 BTDC to partial direct injection (180 BTDC to full direct injection (120 BTDC were investigated. The 300 BTDC injection timing experiment was carried out to simulate the performance of a port injection engine and the result is used as a benchmark for engine performance. The full DI resulted in a 20% higher performance than the early injection timing for low engine speeds up to 2750 rpm. 180 BTDC injection timing shows the highest performance over an extensive range of engine speed because it has a similar volumetric efficiency to full DI. However, the earlier injection timing allowed for a better air–fuel mixing and gives superior performance for engine speeds above 4500 rpm. The engine performance could be explained by analysis of the heat release rate that shows that at low and intermediate engine speeds of 2000 and 3000, the full DI and partial DI resulted in the fastest heat release rate whereas at a high engine speed of 5000 rpm, the simulated port injection operation resulted in the fastest heat release rate.

  13. Colliding pulse injection experiments in non-collinear geometry for controlled laser plasma wakefield acceleration of electrons

    International Nuclear Information System (INIS)

    Toth, Carl B.; Esarey, Eric H.; Geddes, Cameron G.R.; Leemans, Wim P.; Nakamura, Kei; Panasenko, Dmitriy; Schroeder, Carl B.; Bruhwiler, D.; Cary, J.R.

    2007-01-01

    An optical injection scheme for a laser-plasma based accelerator which employs a non-collinear counter-propagating laser beam to push background electrons in the focusing and acceleration phase via ponderomotive beat with the trailing part of the wakefield driver pulse is discussed. Preliminary experiments were performed using a drive beam of a 0 = 2.6 and colliding beam of a 1 = 0.8 both focused on the middle of a 200 mu m slit jet backed with 20 bar, which provided ∼ 260 mu m long gas plume. The enhancement in the total charge by the colliding pulse was observed with sharp dependence on the delay time of the colliding beam. Enhancement of the neutron yield was also measured, which suggests a generation of electrons above 10 MeV

  14. Life management and operational experience feedback - tools to enhance safety and reliability of the NPP

    International Nuclear Information System (INIS)

    Mach, P.

    1997-01-01

    Preparation has started of the Temelin power plant centralized equipment database. Principles of reliability centered maintenance are studied, and use of these activities will be made in the Plant Ageing Management Programme. The aims of the Programme are as follows: selection of important components subject to ageing, data collection, determination of dominant stressors, development, selection and validation of ageing evaluation methods, setup of experience feedback, determination of responsibilities, methodologies and strategy, elaboration of programme procedures and documentation, and maintenance of programme flexibility. Pilot studies of component ageing are under way: for the reactor pressure vessel, steam generator, pressurizer, piping, ECCS and cables. The organizational structure of the Operational Experience Feedback system is described, as are the responsibility of staff and sources of information. (M.D.)

  15. Early Childhood Caries and Body Mass Index in Young Children from Low Income Families

    Directory of Open Access Journals (Sweden)

    Maria Goretti Queiroz

    2013-03-01

    Full Text Available The relationship between early childhood caries (ECC and obesity is controversial. This cross-sectional survey investigated this association in children from low-income families in Goiania, Goias, Brazil and considered the role of several social determinants. A questionnaire examining the characteristics of the children and their families was administered to the primary caregiver during home visits. In addition, children (approximately 6 years of age had their height, weight, and tooth condition assessed. The primary ECC outcome was categorized as one of the following: caries experience (decayed, missing, filled tooth: “dmft” index > 0, active ECC (decayed teeth > 0, or active severe ECC (decayed teeth ≥ 6. Descriptive, bivariate and logistic regression analyses were conducted. The participants in the current study consisted of 269 caregiver-child dyads, 88.5% of whom were included in the Family Health Program. Caregivers were mostly mothers (67.7%, were 35.3 ± 10.0 years old on average and had 9.8 ± 3.1 years of formal education. The mean family income was 2.3 ± 1.5 times greater than the Brazilian minimum wage. On average, the children in the current study were 68.7 ± 3.8 months old. Of these, 51.7% were boys, 23.4% were overweight or obese, 45.0% had active ECC, and 17.1% had severe ECC. The average body mass index (BMI of the children was 15.9 ± 2.2, and their dmft index was 2.5 ± 3.2. BMI was not associated with any of the three categories of dental caries (p > 0.05. In contrast, higher family incomes were significantly associated with the lack of caries experience in children (OR 1.22, 95%CI 1.01–1.50, but the mother’s level of education was not significantly associated with ECC.

  16. Minimized extracorporeal circulation system in coronary artery bypass surgery: a 10-year single-center experience with 2243 patients.

    Science.gov (United States)

    Puehler, Thomas; Haneya, Assad; Philipp, Alois; Zausig, York A; Kobuch, Reinhard; Diez, Claudius; Birnbaum, Dietrich E; Schmid, Christof

    2011-04-01

    Coronary artery bypass grafting (CABG) is the gold standard for the surgical therapy of multivessel coronary artery disease. To reduce the side effects, associated with standard extracorporeal circulation (ECC), a concept of minimal extracorporeal circulation (MECC) was devised in our center. We report on our 10-year experience with the MECC for coronary revascularization. From January 1998 to August 2009, 2243 patients underwent CABG with MECC in our center. In a retrospective observational study, we analyzed indication, preoperative patient co-morbidity, postoperative clinical course, and perioperative outcome of all patients operated on with MECC. Furthermore, the risk factors for mortality in the MECC group were assessed. Patients showed a mean logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) of 4.5±0.1%. The mean age of the patients was 66.8±9.1 years. The overall 30-day mortality after CABG with MECC was 2.3%, ranging from 1.1% for elective to 13.0% for emergent patients and was significantly better than standard ECC. Only 15.3% (n=344) of patients with MECC required intra-operative blood transfusion. Postoperative catecholamine support, red blood cell transfusion, need for hemodialysis, release of creatinine kinase, incidence of stroke, and postoperative delirium were low after MECC revascularization. Ejection fraction below 30% (odds ratio (OR): 5.1), emergent operation (OR: 9.4), and high-dose catecholamine therapy (OR: 2.6) were associated predictors for mortality. MECC until now is an established concept and has become an alternative for ECC in routine CABG in our center. The use of the MECC system is associated with low mortality and conversion rate. Excellent survival rates and low transfusion requirements in the perioperative course were achieved. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  17. Numerical investigation of the effect of injection strategy on mixture formation and combustion process in a port injection natural gas rotary engine

    International Nuclear Information System (INIS)

    Fan, Baowei; Pan, Jianfeng; Yang, Wenming; Liu, Yangxian; Bani, Stephen; Chen, Wei

    2017-01-01

    Highlights: • For injection timing, the fuel movement is controlled by the intensity of the vortex I. • For injection duration, the fuel movement is controlled by the value of jet flux. • The ideal fuel distribution at ignition timing for high combustion rate is studied. • The optimal injection strategy had an increase in the peak pressure and NO emissions. - Abstract: This work aimed to numerically study the influence of injection strategy on mixture formation and combustion process in a port injection natural gas rotary engine. On the base of a 3D dynamic simulation model which was established in our previous work, some critical information was obtained, which was difficult to obtain through experiment, in terms of the flow field, the fuel distribution, the temperature field and the concentration fields of some intermediates. Simulation results showed that for mixture formation, the movements of fuel in injection stage were mainly controlled by the intensity of the vortex I for injection timing, and the value of jet flux for injection duration respectively. With retarded injection timing, the decreasing intensity of the vortex I resulted in less fuel moving toward the back of the combustion chamber. With the extension in injection duration, the decreasing value of jet flux resulted in more fuel staying at the back of the combustion chamber. For combustion process, the overall combustion rate for injection strategy which had an injection timing of 390 °CA (BTDC) and injection duration of 51.5 °CA (case ID4) was the fastest. This was mainly due to the fact that the accumulation area of fuel was at the middle and front of the combustion chamber. Meanwhile, fuel concentration near the leading and trailing spark plugs was conducive for the flame kernel formation. Compared with the injection strategy which had an injection timing of 450 °CA (BTDC) and an injection duration of 55 °CA (case IT1), the improved combustion rate of case ID4 had a 23% increase in

  18. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  19. Large scale gas injection test (Lasgit): Results from two gas injection tests

    International Nuclear Information System (INIS)

    Cuss, R. J.; Harrington, J. F.; Noy, D. J.; Wikman, A.; Sellin, P.

    2011-01-01

    This paper describes the initial results from a large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory (Sweden)). Lasgit is a full-scale field-scale experiment based on the Swedish KBS-3V repository concept, examining the processes controlling gas and water flow in compact buffer bentonite. The first 2 years of the test focused on the artificial hydration of the bentonite buffer. This was followed by a programme of hydraulic and gas injection tests which ran from day 843 to 1110. A further period of artificial hydration occurred from day 1110 to 1385, followed by a more complex programme of gas injection testing which remains on going (day 1385+). After 2 years of hydration, hydraulic conductivity and specific storage values in the lower filter array were found to range from 9 x 10 -14 to 1.6 x 10 -13 m/s and 5.5 x 10 -5 to 4.4 x 10 -4 m -1 respectively, with the injection filter FL903 yielding values of 7.5 x 10 -14 m/s and 2.5 x 10 -5 m -1 . A second set of hydraulic measurements were performed over 1 year and a half later yielding similar values, in the range 7.8 x 10 -14 m/s and 1.3 x 10 -13 m/s. The hydraulic conductivity of FL903 had reduced slightly to 5.3 x 10 -14 m/s while specific storage had increased to 4.0 x 10 -5 m -1 . Both datasets agree with laboratory values performed on small-scale saturated samples. Two sets of gas injection tests were performed over a 3 year period. During the course of testing, gas entry pressure was found to increase from around 650 kPa to approximately 1.3 MPa, indicative of the maturation of the clay. The sequential reduction in volumetric flow rate and lack of correlation between the rate of gas inflow and the gas pressure gradient observed during constant pressure steps prior to major gas entry, is suggestive of a reduction in gas permeability of the buffer and indicates only limited quantities of gas can be injected into the clay without interacting with the continuum stress field. Major gas

  20. An experimental study of fuel injection strategies in CAI gasoline engine

    Energy Technology Data Exchange (ETDEWEB)

    Hunicz, J.; Kordos, P. [Department of Combustion Engines and Transport, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland)

    2011-01-15

    Combustion of gasoline in a direct injection controlled auto-ignition (CAI) single-cylinder research engine was studied. CAI operation was achieved with the use of the negative valve overlap (NVO) technique and internal exhaust gas re-circulation (EGR). Experiments were performed at single injection and split injection, where some amount of fuel was injected close to top dead centre (TDC) during NVO interval, and the second injection was applied with variable timing. Additionally, combustion at variable fuel-rail pressure was examined. Investigation showed that at fuel injection into recompressed exhaust fuel reforming took place. This process was identified via an analysis of the exhaust-fuel mixture composition after NVO interval. It was found that at single fuel injection in NVO phase, its advance determined the heat release rate and auto-ignition timing, and had a strong influence on NO{sub X} emission. However, a delay of single injection to intake stroke resulted in deterioration of cycle-to-cycle variability. Application of split injection showed benefits of this strategy versus single injection. Examinations of different fuel mass split ratios and variable second injection timing resulted in further optimisation of mixture formation. At equal share of the fuel mass injected in the first injection during NVO and in the second injection at the beginning of compression, the lowest emission level and cyclic variability improvement were observed. (author)

  1. Validation of single-fluid and two-fluid magnetohydrodynamic models of the helicity injected torus spheromak experiment with the NIMROD code

    International Nuclear Information System (INIS)

    Akcay, Cihan; Victor, Brian S.; Jarboe, Thomas R.; Kim, Charlson C.

    2013-01-01

    We present a comparison study of 3-D pressureless resistive MHD (rMHD) and 3-D presureless two-fluid MHD models of the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI). HIT-SI is a current drive experiment that uses two geometrically asymmetric helicity injectors to generate and sustain toroidal plasmas. The comparable size of the collisionless ion skin depth d i to the resistive skin depth predicates the importance of the Hall term for HIT-SI. The simulations are run with NIMROD, an initial-value, 3-D extended MHD code. The modeled plasma density and temperature are assumed uniform and constant. The helicity injectors are modeled as oscillating normal magnetic and parallel electric field boundary conditions. The simulations use parameters that closely match those of the experiment. The simulation output is compared to the formation time, plasma current, and internal and surface magnetic fields. Results of the study indicate 2fl-MHD shows quantitative agreement with the experiment while rMHD only captures the qualitative features. The validity of each model is assessed based on how accurately it reproduces the global quantities as well as the temporal and spatial dependence of the measured magnetic fields. 2fl-MHD produces the current amplification (I tor /I inj ) and formation time τ f demonstrated by HIT-SI with similar internal magnetic fields. rMHD underestimates (I tor /I inj ) and exhibits much a longer τ f . Biorthogonal decomposition (BD), a powerful mathematical tool for reducing large data sets, is employed to quantify how well the simulations reproduce the measured surface magnetic fields without resorting to a probe-by-probe comparison. BD shows that 2fl-MHD captures the dominant surface magnetic structures and the temporal behavior of these features better than rMHD

  2. Computer control of the ISX-B neutral injection beamlines

    International Nuclear Information System (INIS)

    Hanna, P.C.

    1982-09-01

    A system of controls for the Impurity Study Experiment (ISX-B) neutral injection beamlines at the Oak Ridge National Laboratory is presented. The system uses standard CAMAC equipment interfaced to the actual beamline controls and driven by a PDP-11/34 mini-computer. It is designed to relieve the operator of most of the mundane tasks of beam injection and also to reduce the number of operators needed to monitor multiple beamlines

  3. Injectable dual redox responsive diselenide-containing poly(ethylene glycol) hydrogel.

    Science.gov (United States)

    Gong, Chu; Shan, Meng; Li, Bingqiang; Wu, Guolin

    2017-09-01

    An injectable dual redox responsive diselenide-containing poly(ethylene glycol) (PEG) hydrogel was successfully developed by combining the conceptions of injectable hydrogels and dual redox responsive diselenides. In the first step, four-armed PEG was modified with N-hydroxysuccinimide (NHS)-activated esters and thereafter, crosslinked by selenocystamine crosslinkers to form injectable hydrogels via the rapid reaction between NHS-activated esters and amino groups. The cross-sectional morphology, mechanical properties, and crosslinking modes of hydrogels were well characterized via scanning electron microscope (SEM), rheological measurements, and Fourier transform infrared spectra, respectively. In addition, the oxidation- and reduction-responsive degradation behaviors of hydrogels were observed and analyzed. The model drug, rhodamine B, was encapsulated in the hydrogel. The drug-loaded hydrogel exhibited a dual redox responsive release profile, which was consistent with the degradation experiments. The results of all experiments indicated that the formulated injectable dual redox responsive diselenide-containing PEG hydrogel can have potential applications in various biomedical fields such as drug delivery and stimuli-responsive drug release. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2451-2460, 2017. © 2017 Wiley Periodicals, Inc.

  4. Dramatic changes in muscle contractile and structural properties after 2 botulinum toxin injections.

    Science.gov (United States)

    Minamoto, Viviane B; Suzuki, Kentaro P; Bremner, Shannon N; Lieber, Richard L; Ward, Samuel R

    2015-10-01

    Botulinum toxin is frequently administered serially to maintain therapeutic muscle paralysis, but the effect of repeated doses on muscle function are largely unknown. This study characterized the muscle response to 2 onabotulinum toxin (BoNT) injections separated by 3 months. Animal subjects received a single toxin injection (n = 8), 2 BoNT injections separated by 3 months (n = 14), or 1 BoNT and 1 saline injection separated by 3 months (n = 8). The functional effect of 2 serial injections was exponentially greater than the effect of a single injection. While both groups treated with a single BoNT injection had decreased torque in the injected leg by approximately 50% relative to contralateral legs, the double BoNT injected group had decreased torque by over 95% relative to the preinjection level. Both single and double BoNT injections produced clear signs of fiber-type grouping. These experiments demonstrate a disproportionately greater effect of repeated BoNT injections. © 2015 Wiley Periodicals, Inc.

  5. Preliminary three-dimensional potential flow simulation of a five-liter flask air injection experiment

    International Nuclear Information System (INIS)

    Davis, J.E.

    1977-01-01

    The preliminary results of an unsteady three-dimensional potential flow analysis of a five-liter flask air injection experiment (small-scale model simulation of a nuclear reactor steam condensation system) are presented. The location and velocity of the free water surface in the flask as a function of time are determined during pipe venting and bubble expansion processes. The analyses were performed using an extended version of the NASA-Ames Three-Dimensional Potential Flow Analysis System (POTFAN), which uses the vortex lattice singularity method of potential flow analysis. The pressure boundary condition at the free water surface and the boundary condition along the free jet boundary near the pipe exit were ignored for the purposes of the present study. The results of the analysis indicate that large time steps can be taken without significantly reducing the accuracy of the solutions and that the assumption of inviscid flow should not have an appreciable effect on the geometry and velocity of the free water surface. In addition, the computation time required for the solutions was well within acceptable limits

  6. The present state of research into plasma heating and injection methods

    International Nuclear Information System (INIS)

    1974-12-01

    The advantages and disadvantages recognized by the Advisory Group on Heating and injection for twelve plasma heating and injection methods currently under investigation in Europe are related. The heating and injection requirements of four reference reactor designs are previously defined. The problems which arise when one attempts to extrapolate existing work towards the reactor goal are emphasized. Two refuelling methods not directly linked with the heating problem are discussed. The experiments in operation or under construction in Europe in which each method is investigated are listed. Sixteen working papers which served as a basis for the Advisory Group discussion and which cover all the heating and injection methods examined are included

  7. Plasma heating by cluster injection: basic features and expected behaviour

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1976-08-01

    The main components of a cluster injection line intended for plasma heating is briefly discussed, that is the beam source, the cluster ionizer and the accelerating tube, as well as the behavior of clusters interacting with a plasma. Outlines of the experiment of cluster injection into TFR, in progress at Fontenay-aux-Roses, and expected results will be presented and discussed all along the paper

  8. Vertical injection of compact torus into the STOR-M tokamak

    International Nuclear Information System (INIS)

    Liu, D.; Singh, A.K.; Hirose, A.; Xiao, C.

    2005-01-01

    Vertical compact torus injection into the STOR-M tokamak has been conducted with the University of Saskatchewan Compact Torus Injector (USCTI). The injector stayed at the horizontal position and the CT was bent by 90 deg. using a curved conducting drift tube. The curved drift tube did not have significant effects on the CT velocity. Furthermore, the curved drift tube did not change the magnetic field topology. Preliminary vertical CT injection experiments have been carried out on the STOR-M tokamak. CT injection induced prompt increase in the electron density and in the soft x-ray radiation level. Further modifications of the 90 deg. are underway to improve the CT parameters and to further study the effects of CT injection on the tokamak plasma parameters. (author)

  9. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  10. Evidence for neutral beam injected oxygen impurities in 2XIIB

    International Nuclear Information System (INIS)

    Drake, R.P.; Moos, H.W.

    1978-01-01

    A series of experiments indicates that the principal source of impurities in the 2XIIB mirror confinement plasma experiment at Lawrence Livermore Laboratory is oxygen in the neutral beams. The dependence of 0 II 539 A emissions on neutral beam current, spatial scans of oxygen emissions, impurity injection experiments, spectral scans of the 0 VI 1032 A line, and other experiments all support this conclusion

  11. Fat Injection: A Systematic Review of Injection Volumes by Facial Subunit.

    Science.gov (United States)

    Shue, Shirley; Kurlander, David E; Guyuron, Bahman

    2017-08-08

    Fat grafting to the aging face has become an integral component of esthetic surgery. However, the amount of fat to inject to each area of the face is not standardized and has been based mainly on the surgeon's experience. The purpose of this study was to perform a systematic review of injected fat volume to different facial zones. A systematic review of the literature was performed through a MEDLINE search using keywords "facial," "fat grafting," "lipofilling," "Coleman technique," "autologous fat transfer," and "structural fat grafting." Articles were then sorted by facial subunit and analyzed for: author(s), year of publication, study design, sample size, donor site, fat preparation technique, average and range of volume injected, time to follow-up, percentage of volume retention, and complications. Descriptive statistics were performed. Nineteen articles involving a total of 510 patients were included. Rhytidectomy was the most common procedure performed concurrently with fat injection. The mean volume of fat injected to the forehead is 6.5 mL (range 4.0-10.0 mL); to the glabellar region 1.4 mL (range 1.0-4.0 mL); to the temple 5.9 mL per side (range 2.0-10.0 mL); to the eyebrow 5.5 mL per side; to the upper eyelid 1.7 mL per side (range 1.5-2.5 mL); to the tear trough 0.65 mL per side (range 0.3-1.0 mL); to the infraorbital area (infraorbital rim to lower lid/cheek junction) 1.4 mL per side (range 0.9-3.0 mL); to the midface 1.4 mL per side (range 1.0-4.0 mL); to the nasolabial fold 2.8 mL per side (range 1.0-7.5 mL); to the mandibular area 11.5 mL per side (range 4.0-27.0 mL); and to the chin 6.7 mL (range 1.0-20.0 mL). Data on exactly how much fat to inject to each area of the face in facial fat grafting are currently limited and vary widely based on different methods and anatomical terms used. This review offers the ranges and the averages for the injected volume in each zone. This journal requires that authors assign a level of evidence

  12. Post-test analysis for the APR1400 LBLOCA DVI performance test using MARS

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Lee, Y. J.; Kim, H. C.; Bae, Y. Y.; Park, J. K.; Lee, W.

    2002-03-01

    Post-test analyses using a multi-dimensional best-estimate analysis code, MARS, are performed for the APR1400 LBLOCA DVI (Direct Vessel Injection) performance tests. This report describes the code evaluation results for the test data of various void height tests and direct bypass tests that have been performed at MIDAS test facility. MIDAS is a scaled test facility of APR1400 with the objective of identifying multi-dimensional thermal-hydraulic phenomena in the downcomer during the reflood conditions of a large break LOCA. A modified linear scale ratio was applied in its construction and test conditions. The major thermal-hydraulic parameters such as ECC bypass fraction, steam condensation fraction, and temperature distributions in downcomer are compared and evaluated. The evaluation results of MARS code for the various test cases show that: (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  13. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  14. Fracture mechanics evaluation of LOFT lower plenum injection nozzle

    International Nuclear Information System (INIS)

    Nagata, P.K.; Reuter, W.G.

    1977-01-01

    An analysis to establish whether or not a leak-before-break concept would apply to the LOFT lower plenum injection nozzle is described. The analysis encompassed the structure from the inlet side of valve V-2170 to the lower plenum nozzle-to-reactor vessel weld on the left side of the emergency core cooling system (ECCS). The defect that was assumed to exist was of such a size that the probability of its being missed by the applicable inspection technique was near zero. The Inconel 600 nozzle forging with an initial assumed defect size of 0.64 cm (0.25 in.) deep would behave as follows: (1) the axially oriented defect would result in leak before rupture (the number of cycles to rupture was 11,000), (2) the circumferentially oriented defect would result in a rupture before leak. The number of cycles to failure would be in excess of 14,000. Based on the conservative assumption that the thermal stresses were membrane stresses as opposed to a bending stress, the following were found. For the Inconel 82 weld metal (thickness of 1.3 cm [0.53 in.]) and AISI 316 SST valve body, with an initial assumed defect of 0.25 cm (0.1 in.), the crack would grow through the thickness in a minimum of 3950 cycles and to a critical rupture crack length of 5.1 cm (2.0 in.) in an additional 80 cycles. The Inconel 82 weld metal at the shell body (thickness of 9.7 cm or 3.8 in.) with an assumed defect 1.3 cm (0.5 in.) deep would fail in 334 cycles. Calculations made assuming a linear stress gradient instead of the above-mentioned flat distribution through the wall indicated that the number of stress cycles increased to 2200

  15. Radiotracer investigations in oil production and water injection wells

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1977-01-01

    Injection of gamma emitting radiotracers into oil wells followed by logging provides information on several aspects such as the identification of zones of seepage of water in the water injection wells and also the location of source of water entering oil producting wells. The experience gained in the application of bromine-82 and rubidium-86 as radiotracers in such studies at the Ankleshwar and Kalol oil fields in Gujarat and Nazira in Assam has been briefly reported. (author)

  16. Modeling the effects of auxiliary gas injection and fuel injection rate shape on diesel engine combustion and emissions

    Science.gov (United States)

    Mather, Daniel Kelly

    1998-11-01

    The effect of auxiliary gas injection and fuel injection rate-shaping on diesel engine combustion and emissions was studied using KIVA a multidimensional computational fluid dynamics code. Auxiliary gas injection (AGI) is the injection of a gas, in addition to the fuel injection, directly into the combustion chamber of a diesel engine. The objective of AGI is to influence the diesel combustion via mixing to reduce emissions of pollutants (soot and NO x). In this study, the accuracy of modeling high speed gas jets on very coarse computational grids was addressed. KIVA was found to inaccurately resolve the jet flows near walls. The cause of this inaccuracy was traced to the RNG k - ɛ turbulence model with the law-of-the-wall boundary condition used by KIVA. By prescribing the lengthscale near the nozzle exit, excellent agreement between computed and theoretical jet penetration was attained for a transient gas jet into a quiescent chamber at various operating conditions. The effect of AGI on diesel engine combustion and emissions was studied by incorporating the coarse grid gas jet model into a detailed multidimensional simulation of a Caterpillar 3401 heavy-duty diesel engine. The effects of AGI timing, composition, amount, orientation, and location were investigated. The effects of AGI and split fuel injection were also investigated. AGI was found to be effective at reducing soot emissions by increasing mixing within the combustion chamber. AGI of inert gas was found to be effective at reducing emissions of NOx by depressing the peak combustion temperatures. Finally, comparison of AGI simulations with experiments were conducted for a TACOM-LABECO engine. The results showed that AGI improved soot oxidation throughout the engine cycle. Simulation of fuel injection rate-shaping investigated the effects of three injection velocity profiles typical of unit-injector type, high-pressure common-rail type, and accumulator-type fuel injectors in the Caterpillar 3401 heavy

  17. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2010-01-01

    as well as with the filling of the cavity by the polymer melt. In this paper, two parameters derived from cavity pressure over time (i.e. pressure work). The influence of four µIM parameters (melt temperature, mould temperature, injection speed, aand packing pressure) on the two pressure-related outputs...... has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been......Process monitoring of micro injection moulding (µIM) is of crusial importance to analyse the effect of different parameter settings on the process and to assess its quality. Quality factors related to cavity pressure can provide useful information directly connected with the dyanmics of the process...

  18. Penetration and delivery characteristics of repetitive microjet injection into the skin.

    Science.gov (United States)

    Römgens, Anne M; Rem-Bronneberg, Debbie; Kassies, Roel; Hijlkema, Markus; Bader, Dan L; Oomens, Cees W J; van Bruggen, Michel P B

    2016-07-28

    Drugs can be delivered transdermally using jet injectors, which can be an advantageous route compared to oral administration. However, these devices inject large volumes deep into the skin or tissues underneath the skin often causing bruising and pain. This may be prevented by injecting smaller volumes at lower depth in a repetitive way using a microjet injection device. Such a device could be used to apply drugs in a controllable and sustainable manner. However, the efficacy of microjet injection has been rarely examined. In this study, the penetration and delivery capacity was examined of a repetitive microjet injection device. Various experiments were performed on epidermal and full-thickness ex vivo human as well as ex vivo porcine skin samples. Results revealed that microjets with a velocity exceeding 90m/s penetrated an epidermal skin sample with a delivery efficiency of approximately 96%. In full-thickness human skin, the delivery efficiency drastically decreased to a value of approximately 12%. Experiments on full-thickness skin revealed that the microjets penetrated to a depth corresponding to the transition between the papillary and reticular dermis. This depth did not further increase with increasing number of microjets. In vivo studies on rats indicated that intact insulin was absorbed into the systemic circulation. Hence, the microjet injection device was able to deliver medication into the skin, although the drug delivery efficiency should be increased. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Sensitivity analysis of MIDAS tests using SPACE code. Effect of nodalization

    International Nuclear Information System (INIS)

    Eom, Shin; Oh, Seung-Jong; Diab, Aya

    2018-01-01

    The nodalization sensitivity analysis for the ECCS (Emergency Core Cooling System) bypass phe�nomena was performed using the SPACE (Safety and Performance Analysis CodE) thermal hydraulic analysis computer code. The results of MIDAS (Multi-�dimensional Investigation in Downcomer Annulus Simulation) test were used. The MIDAS test was conducted by the KAERI (Korea Atomic Energy Research Institute) for the performance evaluation of the ECC (Emergency Core Cooling) bypass phenomenon in the DVI (Direct Vessel Injection) system. The main aim of this study is to examine the sensitivity of the SPACE code results to the number of thermal hydraulic channels used to model the annulus region in the MIDAS experiment. The numerical model involves three nodalization cases (4, 6, and 12 channels) and the result show that the effect of nodalization on the bypass fraction for the high steam flow rate MIDAS tests is minimal. For computational efficiency, a 4 channel representation is recommended for the SPACE code nodalization. For the low steam flow rate tests, the SPACE code over-�predicts the bypass fraction irrespective of the nodalization finesse. The over-�prediction at low steam flow may be attributed to the difficulty to accurately represent the flow regime in the vicinity of the broken cold leg.

  20. Sensitivity analysis of MIDAS tests using SPACE code. Effect of nodalization

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Shin; Oh, Seung-Jong; Diab, Aya [KEPCO International Nuclear Graduate School (KINGS), Ulsan (Korea, Republic of). Dept. of NPP Engineering

    2018-02-15

    The nodalization sensitivity analysis for the ECCS (Emergency Core Cooling System) bypass phe�nomena was performed using the SPACE (Safety and Performance Analysis CodE) thermal hydraulic analysis computer code. The results of MIDAS (Multi-�dimensional Investigation in Downcomer Annulus Simulation) test were used. The MIDAS test was conducted by the KAERI (Korea Atomic Energy Research Institute) for the performance evaluation of the ECC (Emergency Core Cooling) bypass phenomenon in the DVI (Direct Vessel Injection) system. The main aim of this study is to examine the sensitivity of the SPACE code results to the number of thermal hydraulic channels used to model the annulus region in the MIDAS experiment. The numerical model involves three nodalization cases (4, 6, and 12 channels) and the result show that the effect of nodalization on the bypass fraction for the high steam flow rate MIDAS tests is minimal. For computational efficiency, a 4 channel representation is recommended for the SPACE code nodalization. For the low steam flow rate tests, the SPACE code over-�predicts the bypass fraction irrespective of the nodalization finesse. The over-�prediction at low steam flow may be attributed to the difficulty to accurately represent the flow regime in the vicinity of the broken cold leg.

  1. Alpha particle diagnostics using impurity pellet injection (invited)

    International Nuclear Information System (INIS)

    Fisher, R.K.; McChesney, J.M.; Howald, A.W.; Parks, P.B.; Snipes, J.A.; Terry, J.L.; Marmar, E.S.; Zweben, S.J.; Medley, S.S.

    1992-01-01

    We have proposed using impurity pellet injection to measure the energy distribution of the fast confined alpha particles in a reacting plasma [R. K. Fisher et al., Fusion Technol. 13, 536 (1988)]. The ablation cloud surrounding the injected pellet is thick enough that an equilibrium fraction F ∞ 0 (E) of the incident alphas should be neutralized as they pass through the cloud. By observing neutrals created in the large spatial region of the cloud which is expected to be dominated by the heliumlike ionization state, e.g., Li + ions, we can determine the incident alpha distribution dn He 2+ /dE from the measured energy distribution of neutral helium atoms dn He 0 /dE using dn He 0 /dE = dn He 2+ /dE·F ∞ 0 (E,Li + ). Initial experiments were performed on the Texas Experimental Tokamak (TEXT) in which we compared pellet penetration with our impurity pellet ablation model [P. B. Parks et al., Nucl. Fusion 28, 477 (1988)], and measured the spatial distribution of various ionization states in carbon pellet clouds [R. K. Fisher et al., Rev. Sci. Instrum. 61, 3196 (1990)]. Experiments have recently begun on the Tokamak Fusion Test Reactor (TFTR) with the goal of measuring the alpha particle energy distribution during D--T operation in 1993--94. A series of preliminary experiments are planned to test the diagnostic concept. The first experiments will observe neutrals from beam-injected deuterium ions and the high energy 3 He tail produced during ion cyclotron (ICH) minority heating on TFTR interacting with the cloud. We will also monitor by line radiation the charge state distributions in lithium, boron, and carbon clouds

  2. The channeling experiment - instrumentation and site preparation

    International Nuclear Information System (INIS)

    Abelin, H.; Birgersson, L.; Aagren, T.

    1990-01-01

    Physical properties of in situ single fractures have been investigated by drilling large diameter holes (200 mm) 2.5 to 3 m into and along prominent single fractures. Photo logs as well as hydraulic- tracer tests have been performed. The experiment is divided into two parts, (1) the single hole experiments and (2) the double hole experiment. In the single hole experiment water was injected into the fracture and the injection flowrates over 50 mm sections along the fracture plane were monitored. In the double hole test two parallel large diameter holes, in the same fracture, 1.75 m apart, have been used for pressure pulse tests and a tracer test where 5 different nonsorbing tracers were injected. Equipment has been designed for water injection into single fractures where injection flowrates and pressure responses are simultaneously monitored in twenty 50 mm sections along the intersection of the fracture with the bore hole. The Multipede injection packer designed to be used in diameter 200 mm bore hole with a maximum depth of 2.5 m. Injection is done with constant pressure which is stable within ±0.0025 bar, and can be separately adjusted for each of the 20 injection zones. Injection flowrates can be monitored with a resolution of 1/100 ml/h, which equals one drop of water every five hours. The injection and pressure pulse tests are run by a computer and all data are stored on magnetic disks. A fracture survey at the 360 m level and adjacent levels has been done. The survey focused on prominent planar fractures with extension of more than 2 m. Approximately 100 fractures were found. (authors)

  3. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  4. A Comparison of Fueling with Deuterium Pellet Injection from Different Locations on the DIII-D Tokamak

    International Nuclear Information System (INIS)

    Baylor, L.R.; Combs, S.K.; Gohil, P.; Houlberg, W.A.; Hsieh, C.; Jernigan, T.C.; Parks, P.B.

    1999-01-01

    Initial pellet injection experiments on DIII-D with high field side (HFS) injection have demonstrated that deeper pellet fuel deposition is possible even with HFS injected pellets that are significantly slower than pellets injected from the low field side (LFS) (outer midplane) location. A radial displacement of the pellet mass shortly after or during the ablation process is consistent with the observed mass deposition profiles measured shortly after injection. Vertical injection inside the magnetic axis shows some improvement in fueling efficiency over LFS injection and may provide an optimal injection location for fueling with high speed pellets

  5. Nutrient accumulation and biomass production of alfafa after soil amendment with silicates

    Directory of Open Access Journals (Sweden)

    Angélica Cristina Fernandes Deus

    2014-06-01

    Full Text Available Studies on the use of silicate correctives in agriculture show that they have great potential to improve soil chemical characteristics, however, little information is available on the reactivity rates of their particle-size fractions. This study investigated whether the reactivity rates obtained experimentally could be considered in the calculation of ECC (effective calcium carbonate for soil liming, promoting adequate development of alfalfa plants. Six treatments were evaluated in the experiment, consisting of two slag types applied in two rates. The experimental ECC was used to calculate one of the rates and the ECC determined in the laboratory was used to calculate the other. Rates of limestone and wollastonite were based on the ECC determined in laboratory. The rates of each soil acidity corretive were calculated to increase the base saturation to 80%. The treatments were applied to a Rhodic Hapludox and an Alfisol Ferrudalfs. The methods for ECC determination established for lime can be applied to steel slag. The application of slag corrected soil acidity with consequent accumulation of Ca, P, and Si in alfalfa, favoring DM production.

  6. A three-dimensional laboratory steam injection model allowing in situ saturation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Demiral, B.M.R.; Pettit, P.A.; Castanier, L.M.; Brigham, W.E.

    1992-08-01

    The CT imaging technique together with temperature and pressure measurements were used to follow the steam propagation during steam and steam foam injection experiments in a three dimensional laboratory steam injection model. The advantages and disadvantages of different geometries were examined to find out which could best represent radial and gravity override flows and also fit the dimensions of the scanning field of the CT scanner. During experiments, steam was injected continuously at a constant rate into the water saturated model and CT scans were taken at six different cross sections of the model. Pressure and temperature data were collected with time at three different levels in the model. During steam injection experiments, the saturations obtained by CT matched well with the temperature data. That is, the steam override as observed by temperature data was also clearly seen on the CT pictures. During the runs where foam was present, the saturation distributions obtained from CT pictures showed a piston like displacement. However, the temperature distributions were different depending on the type of steam foam process used. The results clearly show that the pressure/temperature data alone are not sufficient to study steam foam in the presence of non-condensible gas.

  7. Experiments on the injection, confinement, and ejection of electron clouds in a magnetic mirror

    International Nuclear Information System (INIS)

    Eckhouse, S.; Fisher, A.; Rostoker, N.

    1978-01-01

    A cloud of (5 to 10 keV) electrons is injected into a magnetic mirror field. The magnetic field rises in 40--120 μsec to a maximum of 10 kG. Two methods of injection were tried: In the first, the injector is located at the mirror midplane and electrons are injected perpendicular to the magnetic field lines. In the second scheme, the injector is located near the mirror maximum. Up to about 10 11 electrons were trapped in both schemes with a mean kinetic energy of 0.3 MeV. Measured confinement time is limited only by the magnetic field decay time. The compressed electron cloud executes electrostatic oscillations. The frequency of the oscillation is proportional to the number of electrons trapped, and it is independent of the value of the magnetic field and the initial electron energy. The electron cloud was ejected along the mirror axis and properties of the ejected electron cloud were measured by x-ray pulses from bremstrahlung of electrons on the vacuum system wall and by collecting electrons on a Faraday cup

  8. Comparison between gas puffing and supersonic molecular beam injection in plasma density feedback experiments in EAST

    International Nuclear Information System (INIS)

    Zheng, Xingwei; Li, Jiangang; Hu, Jiansheng; Li, Jiahong; Ding, Rui; Cao, Bin; Wu, Jinhua

    2013-01-01

    To achieve desirable plasma density control, a supersonic molecular beam injection (SMBI) feedback control system has been developed recently for the EAST tokamak. The performance of the SMBI and gas puffing (GP) feedback systems were used and compared. The performance of pulse width mode is better than that of pulse amplitude mode when GP was used for density feedback control. During one-day experiments, the variation of gas input and wall retention can be clarified into two stages. In the first stage the retention ratio is as high as 80–90%, and the gas input is about an order of 10 22 D 2 . However, in the second stage, the retention ratio is at a range of 50–70%. The gas input of a single discharge is small and the net wall retention grows slowly. The results of the SMBI feedback control experiment was analyzed. The shorter delay time of SMBI makes it faster at feeding back control the plasma density. The result showed that, compared with GP, the gas input of SMBI was decreased ∼30% and the wall retention was reduced ∼40%. This shows SMBI's advantage for the long pulse high density discharges in EAST. (paper)

  9. Improvements in numerical modelling of highly injected crystalline silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Altermatt, P.P. [University of New South Wales, Centre for Photovoltaic Engineering, 2052 Sydney (Australia); Sinton, R.A. [Sinton Consulting, 1132 Green Circle, 80303 Boulder, CO (United States); Heiser, G. [University of NSW, School of Computer Science and Engineering, 2052 Sydney (Australia)

    2001-01-01

    We numerically model crystalline silicon concentrator cells with the inclusion of band gap narrowing (BGN) caused by injected free carriers. In previous studies, the revised room-temperature value of the intrinsic carrier density, n{sub i}=1.00x10{sup 10}cm{sup -3}, was inconsistent with the other material parameters of highly injected silicon. In this paper, we show that high-injection experiments can be described consistently with the revised value of n{sub i} if free-carrier induced BGN is included, and that such BGN is an important effect in silicon concentrator cells. The new model presented here significantly improves the ability to model highly injected silicon cells with a high level of precision.

  10. Pseudorandom binary injection of levitons for electron quantum optics

    Science.gov (United States)

    Glattli, D. C.; Roulleau, P.

    2018-03-01

    The recent realization of single-electron sources lets us envision performing electron quantum optics experiments, where electrons can be viewed as flying qubits propagating in a ballistic conductor. To date, all electron sources operate in a periodic electron injection mode, leading to energy spectrum singularities in various physical observables which sometimes hide the bare nature of physical effects. To go beyond this, we propose a spread-spectrum approach where electron flying qubits are injected in a nonperiodic manner following a pseudorandom binary bit pattern. Extending the Floquet scattering theory approach from periodic to spread-spectrum drive, the shot noise of pseudorandom binary sequences of single-electron injection can be calculated for leviton and nonleviton sources. Our new approach allows us to disentangle the physics of the manipulated excitations from that of the injection protocol. In particular, the spread-spectrum approach is shown to provide better knowledge of electronic Hong-Ou-Mandel correlations and to clarify the nature of the pulse train coherence and the role of the dynamical orthogonality catastrophe for noninteger charge injection.

  11. Ideal magnetohydrodynamic simulations of unmagnetized dense plasma jet injection into a hot strongly magnetized plasma

    OpenAIRE

    Liu, Wei; Hsu, Scott C.

    2010-01-01

    We present results from three-dimensional ideal magnetohydrodynamic simulations of unmagnetized dense plasma jet injection into a uniform hot strongly magnetized plasma, with the aim of providing insight into core fueling of a tokamak with parameters relevant for ITER and NSTX (National Spherical Torus Experiment). Unmagnetized dense plasma jet injection is similar to compact toroid injection but with much higher plasma density and total mass, and consequently lower required injection velocit...

  12. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  13. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Development and integration of a 50 Hz pellet injection system for the Experimental Advanced Superconducting Tokamak (EAST)

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Xingjia [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Science Island Branch of Graduate School, University of Science and Technology of China, Hefei 230029 (China); Chen, Yue [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, Jiansheng, E-mail: hujs@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Vinyar, Igor; Lukin, Alexander [PELIN, Saint-Petersburg (Russian Federation); Yuan, Xiaoling; Li, Changzheng; Liu, Haiqing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2017-01-15

    Highlights: • The design of the pumping system fits the operation requirement well not only theoretically but also experimentally. • The data showed that the averaged pellet injection velocity and propellant gas pressure had a relationship submitting to the power function. • The reliability of the injected pellet was mostly around 90% which is higher than the PI-20 system thanks to the improved pumping system and the new pellet fabrication and acceleration system. - Abstract: A 50 Hz pellet injection system, which is designed for edge-localized mode (ELM) control, has been successfully developed and integrated for the Experimental Advanced Superconducting Tokamak (EAST). Pellet injection is achieved by two separated injection system modules that can be operated independently from 1 to 25 Hz. The nominal injection velocity is 250 m/s with a scatter of ±50 m/s at a repetition rate of 50 Hz. A buffer tank and a two-stage differential pumping system of the pellet injection system was designed to increase hydrogen/deuterium ice quality and eliminate the influence of propellant gas on plasma operation, respectively. The pressure of the buffer tank could be pumped to 1 × 10{sup 2} Pa, and the pressure in the second differential chamber could reach 1 × 10{sup −4} Pa during the experiment. Engineering experiments, which consisted of 50 Hz pellet injection and guiding tube mock-up experiments, were also systematically carried out in a laboratory environment and demonstrated that the pellet injection system can reliably inject pellets at a repetitive frequency of 50 Hz.

  15. Hydrogen pellet injection into Alcator C

    International Nuclear Information System (INIS)

    Greenwald, M.

    1983-09-01

    A four-shot pneumatic pellet injector, based on an ORNL design, has been built and operated on the Alcator C tokamak at MIT. The injector fires four independently-timed frozen hydrogen pellets with velocities in the range 8 x 10 4 - 1 x 10 5 cm/sec. Each contains 6 x 10 19 particles which corresponds to = 2 x 10 14 /cm 3 . The objectives of this experiment are to study pellet fueling and penetration, particle confinement, dependence of energy confinement on density profile and fueling mode, and edge physics and recycling as a function of fueling mode. Typical pre-injection plasmas have had anti n/sub e/ = 2 - 3 x 10 14 , Bt = 80 - 100 kG, Ip = 400 - 500 kA, T/sub e/(0) = 1200 - 1500 ev. A single pellet injected into this plasma will roughly double the electron density. Record plasma densities have been obtained by multiple injections. Line average densities in excess of 8 x 10 14 have been achieved, with highly peaked profiles. Central densities of 1.5 - 2 x 10 15 have been measured

  16. Conceptual design of a neutral-beam injection system for the TFTR

    International Nuclear Information System (INIS)

    Ehlers, K.W.; Berkner, K.H.; Cooper, W.S.; Hooper, E.B.; Pyle, R.V.; Stearns, J.W.

    1975-11-01

    The neutral-beam injection requirements for heating and fueling the next generation of fusion reactor experiments far exceed those of present devices; the neutral-beam systems needed to meet these requirements will be large and complex. A conceptual design of a TFTR tokamak injection system to produce 120 keV deuterium-ion beams with a total power of about 80 MW is given

  17. Evaluation of upward migration around a deep injection well

    International Nuclear Information System (INIS)

    Chia, Yeeping; Chiu, J.

    1994-01-01

    The long-term containment of injected wastes in the deep subsurface is expected to be achieved under suitable geologic and hydrologic conditions and by the use of competent engineering practices. Field experiences, however, indicate that waste containment may be affected by hydrologic conduits around the injection well. To assess the potential effects of these conduits, upward migration of injected waste is examined through the use of numerical models under various conditions. Test results indicate that without any preferential hydrologic conduits, most of the injected waste moves laterally in the injection interval, whereas only a small amount of waste migrates upward into the containment interval. When vertical fractures in the disturbed zone or defects in the cement seal around the wellbore exist, the contaminant can move rapidly upward along these conduits to an overlying aquifer, from which it migrates in the lateral direction. The contamination of the overlying aquifer that results from the upward migration of injected waste through these conduits cannot be impeded by a thick, low-permeability containment interval. However, when permeable interbeds exist within the containment interval, a significant portion of the waste migrating upward can be diverted laterally before reaching the overlying aquifer. The front of built-up pressure can reach the aquifer or permeable interbed immediately overlying the injection interval through the preferential hydrologic conduits shortly after the injection starts, but it cannot move farther upward because of pressure dissipation in the permeable formation. This study suggests that the injected waste has the potential to migrate upward into overlying formations through preferential migration conduits around the wellbore

  18. Frequent food insecurity among injection drug users: correlates and concerns

    Directory of Open Access Journals (Sweden)

    Strike Carol

    2012-12-01

    Full Text Available Abstract Background Food insecurity and nutrition are two topics that are under-researched among injection drug users (IDUs. Our study examined the extent and correlates of food insecurity among a sample of IDUs and explored whether there is an association between food insecurity and injection-related HIV risk. Methods A cross-sectional survey was conducted using interviewer-administered questionnaires. Data were collected at a needle exchange program in London, Ontario, Canada between September 2006 and January 2007. Participants included 144 English-speaking IDUs who had injected drugs in the past 30 days. Participants were asked about their socio-demographic characteristics, HIV risk behaviours, food insecurity, and health/social service use. Results In the past 6 months, 54.5% of participants reported that on a daily/weekly basis they did not have enough to eat because of a lack of money, while 22.1% reported this type of food insecurity on a monthly basis. Moreover, 60.4% and 24.3% reported that they did not eat the quality or quantity of food they wanted on a daily/weekly or a monthly basis, respectively. Participants reported re-using someone else’s injection equipment: 21% re-used a needle, 19% re-used water, and 37.3% re-used a cooker. The odds of sharing injection equipment were increased for food insecure individuals. Conclusions Findings show that IDUs have frequent and variable experiences of food insecurity and these experiences are strongly correlated with sharing of injection-related equipment. Such behaviours may increase the likelihood of HIV and HCV transmission in this population. Addressing food-related needs among IDUs is urgently needed.

  19. Influence of hypodermic needle dimensions on subcutaneous injection delivery - a pig study of injection deposition evaluated by CT scanning, histology, and backflow

    DEFF Research Database (Denmark)

    Ann Praestmark Juul, Kezia; Bengtsson, Henrik; Eyving, Bente

    2012-01-01

    , little is known about local drug delivery in relation to needle length and thickness. This study aimed to compare deposition depth and backflow from three hypodermic needles of 3 mm 34G (0.19 mm), 5 mm 32G (0.23 mm), and 8 mm 30G (0.30 mm) in length and thickness. METHODS: Ex vivo experiments were......BACKGROUND: Thinner and shorter needles for subcutaneous administration are continuously developed. Previous studies have shown that a thinner needle causes fewer occurrences of painful needle insertions and that a shorter needle decreases the occurrence of painful intramuscular injections. However...... depth, the bulk of the injection was in the subcutaneous tissue and did not propagate from subcutis into dermis. With the 8 mm 30G needle all injections apart from one intramuscular injection were located in the subcutaneous layer. The volume depositions peaked in 4-5 mm depth for the 3 mm 34G needle...

  20. Groundwater monitoring for deep-well injection

    International Nuclear Information System (INIS)

    Chia, Y.; Chiu, J.

    1994-01-01

    A groundwater monitoring system for detecting waste migration would not only enhance confidence in the long-term containment of injected waste, but would also provide early warnings of contamination for prompt responses to protect underground sources of drinking water (USDWs). Field experiences in Florida have demonstrated monitoring water quality and fluid pressure changes in overlying formations is useful in detecting the upward migration of injected waste. Analytical and numerical solutions indicate changes in these two monitoring parameters can vary on the basis of hydrogeologic characteristics, operation conditions, and the distances from the injection well to the monitoring wells and to the preferential hydrologic conduits. To detect waste migration through defects around the wellbore or the leaky containment interval, groundwater monitoring wells should be placed as close as possible to an injection well. In the vertical direction, a monitoring well completed in a permeable interbed within the containment interval is expected to have the highest potential for detecting upward migration. Another acceptable horizon for groundwater monitoring is the lower portion of the buffer brine aquifer immediately above the containment interval. Monitoring wells in USDWs may be needed when waste has been detected in deeper formations or when leakage out of well casings poses a concern. A monitoring well open to the injection interval is of little value in alleviating the concerns of long-term upward migration. Moreover, the installation of the well could create additional preferential pathways. Complications in groundwater monitoring may arise at existing injection sites, especially with prior releases. It is also important to recognize that monitoring in the vicinity of the wellbore may not be effective for detecting waste migration through unidentified unplugged wells or undetected transmissive fractures

  1. Spin injection across a hybrid heterojunction: Theoretical understanding and experimental approach (invited)

    DEFF Research Database (Denmark)

    Hu, C.M.; Nitta, J.; Jensen, Ane

    2002-01-01

    Spin injection across a hybrid ferromagnet/semiconductor junction has proven to be difficult, unlike in an all-metal junction used in giant magnetoresistance devices. The difference responsible is highlighted in a simple model. We perform spin-injection-detection experiments on devices with two...... ferromagnetic contacts on a two-dimensional electron gas confined in an InAs quantum well. We demonstrate that spin injection allows the hybrid device to combine both the advantage of the ferromagnet as well as that of the semiconductor....

  2. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  3. Asymptotic analysis soot model and experiment for a directed injection engine

    Science.gov (United States)

    Liu, Yongfeng; Pei, Pucheng; Xiong, Qinghui; Lu, Yong

    2012-09-01

    The existing soot models are either too complex and can not be applied to the internal combustion engine, or too simple to make calculation errors. Exploring the soot model becomes the pursuit of the goal of many researchers within the error range in the current computer speed. On the basis of the latest experimental results, TP (temperature phases) model is presented as a new soot model to carry out optimization calculation for a high-pressure common rail diesel engine. Temperature and excess air factor are the most important two parameters in this model. When zone temperature T0.6, only the soot precursors—polycyclic aromatic hydrocarbons(PAH) is created and there is no soot emission. When zone temperature T ⩾ 1 500 K and excess air factor Φinjection time, variation of rail pressure and variation of speed among TP models. The experimental results indicate that the TP model can carry out optimization and computational fluid dynamics can be a tool to calculate for a high-pressure common rail directed injection diesel engine. The TP model result is closer than the use of the original KIVA-3V results of soot model accuracy by about 50% and TP model gives a new method for engine researchers.

  4. Post-injection delirium/sedation syndrome in patients with schizophrenia treated with olanzapine long-acting injection, II: investigations of mechanism

    Directory of Open Access Journals (Sweden)

    Stickelmeyer Mary

    2010-06-01

    Full Text Available Abstract Background Olanzapine long-acting injection (LAI is a salt-based depot antipsychotic combining olanzapine and pamoic acid. The slow intramuscular dissolution of this practically insoluble salt produces an extended release of olanzapine lasting up to 4 weeks. However, in a small number of injections ( Methods Healthcare providers involved in the PDSS cases were queried for clinical information around the events. Plasma samples from patients experiencing PDSS were collected when possible (12/30 cases and olanzapine concentrations compared with the known pharmacokinetic profile for olanzapine LAI. Product batches and used vials from the PDSS cases were evaluated for compliance with established manufacturing standards and/or possible user error. Because this depot formulation depends upon slow dissolution at the intramuscular injection site, in-vitro experiments were conducted to assess solubility of olanzapine pamoate in various media. Results Injection administrators reported no unusual occurrences during the injection. No anomalies were found with the product batches or the remaining suspension in the used vials. Olanzapine concentrations during PDSS events were higher than the expected 5-73 ng/mL range, with concentrations exceeding 100 ng/mL and in some cases reaching >600 ng/mL during the first hours after injection but then returning to the expected therapeutic range within 24 to 72 hours. Solubility and dissolution rate of olanzapine pamoate were also found to be substantially greater in plasma than in other media such as those approximating the environment in muscle tissue. Conclusions Manufacturing irregularities, improper drug reconstitution, and inappropriate dosing were ruled out as possible causes of PDSS. In-vitro solubility and in-vivo pharmacokinetic investigations suggest that PDSS is related to exposure of the injected product to a substantial volume of blood. This exposure is most likely the result of unintended partial

  5. The ''injection problem'' for quasiparallel shocks

    International Nuclear Information System (INIS)

    Zank, G. P.; Rice, W. K. M.; le Roux, J. A.; Cairns, I. H.; Webb, G. M.

    2001-01-01

    For a particle to be accelerated diffusively at a shock by the first-order Fermi acceleration mechanism, the particle must be sufficiently energetic that it can scatter across all the micro- and macrostructure of the shock, experiencing compression between the converging upstream and downstream states. This is the well-known ''injection problem.'' Here the interaction of ions with the ramp of a quasiparallel shock is investigated. Some ions incident on the shock experience specular reflection, caused either by the cross-shock electrostatic potential or by mirroring as the magnetic field is bent and compressed through the ramp. Scattering of reflected ions by self-generated and pre-existing turbulence in the region upstream of the shock then acts to trap backstreaming ions and return them to the ramp, where some experience further reflections. Such repeated reflections and scattering energize a subpopulation of ions up to energies sufficiently large that they can be diffusively shock accelerated. Two ion distributions are considered: pickup ions which are assumed to be described by a shell distribution, are thermal solar wind ions which may be described by a kappa distribution. Injection efficiencies are found analytically to be very high for pickup ions and much lower for thermal solar wind ions, suggesting that this injection mechanism, stochastic reflected ion or SRI acceleration, is a natural precursor for the acceleration of the anomalous cosmic ray component at a quasiparallel shock. While significantly less efficient, SRI acceleration is also viable for thermal solar wind ions described by a kappa distribution

  6. The computation of properties of injection-moulded products

    NARCIS (Netherlands)

    Douven, L.F.A.; Baaijens, F.P.T.; Meijer, H.E.H.

    1995-01-01

    Injection moulding is a flexible production technique for the manufacture of complex shaped, thin walled polymer products that require minimal finishing. During processing, the polymer experiences a complex deformation and temperature history that affects the final properties of the product. In a

  7. Characterisation of demoulding parameters in micro‑injection moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Tosello, Guido; Dimov, S.S.

    2015-01-01

    on the process factors that affect parts’ quality. Using a Cyclic Olefin Copolyme (COC) microfluidics demonstrator, the demoulding performance was studied as a function of four process parameters (melt temperature, mould temperature, holding pressure and injection speed), employing the design of experiment...

  8. Simulation of a loss of primary coolant accident due to a large break in Angra 2 Nuclear Power Plant with RELAP5/MOD3.2.2G code

    International Nuclear Information System (INIS)

    Sabunddjian, Gaiane; Andrade, Delvonei Alves de

    2003-01-01

    This work presents the simulation, with RELAP5/MOD.3.2.2G code, of the postulate accident with loss of coolant in the primary circuit for large break (LBLOCA), which is described in Chapter 15 of the Final Safety Analysis Report of Angra 2 FSAR. The accident consists basically of the total break of the cold leg (Loop 20) of Angra 2 Plant. The rupture area considered is 4418 cm 2 , which represents 100% of the primary circuit pipe flow area. The Emergency Core Cooling System (ECCS) efficiency is also verified for this accident. In this simulation, failure and repair criteria are adopted for the ECCS components, in order to verify the system operation, in carrying out its function as expected by the project to preserve the integrity of the reactor core and to guarantee its cooling. LBLOCA accidents are characterized by a fast blowdown in the primary circuit to values that the low pressure injection system is activated and then, followed by the water injection by the accumulators. The thermal-hydraulic processes inherent to the accident phenomenon, such as hot leg vaporization and consequently core vaporization causing an inappropriate flow distribution in the reactor core, can lead to a reduction in the core liquid level, until the ECCS is capable to reflood it. It is important to point out that the results do not represent an independent calculation for the licensing process, but a calculation to give support to the qualification process of Angra 2 transient basic nodalization (author)

  9. Simulation studies of steam-propane injection for the Hamaca heavy oil field

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, G.J.; Mamora, D.D. [Texas A and M Univ., Austin, TX (United States)

    2003-07-01

    Laboratory experiments have been conducted at Texas A and M University to examine the use of steam additives such as propane, methane and nitrogen to improve the production of heavy oils and increase steam recovery efficiency. In particular, the use of steam-propane injection for heavy Hamaca crude oil with API gravity of 9.3 and viscosity of 25,000 cp at 50 degrees C was examined. Experimental runs involved the injection of steam or propane into injection cells at a constant rate, temperature and cell outlet pressure. The experimental results suggest that the use of steam-propane injection may translate to reduction of fuel costs for field injections. Initially, propane-steam injection resulted in a two-month oil production acceleration compared to pure steam injection. A significant gain in discounted revenue and savings in steam injection costs could be realized. The study also showed the oil product rate peak with steam-propane injection was much higher than that with pure steam injection. The oil production acceleration increases with increasing propane content. Oil recovery at the end of a five-year forecast period increases by 6.7 per cent of original oil in place (OOIP) compared to 2.3 per cent OOIP with pure steam injection. 12 refs., 6 tabs., 28 figs.

  10. Avaliação da resistência a fadiga dos Engineered Cementitious Composites (ecc, reforçados com fibra de polipropileno e produzidos com adição de cinza de casca de arroz

    Directory of Open Access Journals (Sweden)

    Alceu Lopes de Freitas Júnior

    2017-07-01

    Full Text Available O Engineered Cementitious Composites - ECC – é um tipo especial de compósito cimentício de alto desempenho reforçado com fibra, cuja principal característica é a alta ductilidade. O traço de ECC é composto por cimento, material pozolânico, agregado miúdo e fibras. Este estudo avaliou a resistência à fadiga de traços de Engineered Cementitious Composites reforçados com fibras de polipropileno - PPECC – e cuja composição da matriz cimentícia tenha a incorporação de cinza de casca de arroz como material suplementar. Para isto, foram produzidos corpos de prova com substrato de concreto para pavimento e overlay com o traço de PPECC desenvolvido. Os corpos de prova foram submetidos aos ensaios de flexão a quatro pontos (estático e cíclico. Compararam-se os resultados obtidos no ensaio estático dos traços de PPECC com os resultados obtidos neste mesmo ensaio com corpos de prova produzidos somente por concreto para pavimento. Foram analisados os resultados dos ensaios cíclicos em diferentes intervalos de tensões. Com os resultados variação da tensão x números de ciclos, obtidos no ensaio cíclico, foi avaliado o comportamento à fadiga do compósito.

  11. FIX-II/3025, BWR FIX-II Pump Trip Experiment 3025, Immediate Split Size Break

    International Nuclear Information System (INIS)

    NILSSON, Lars; GUSTAFSSON, Per-Ake; GUSTAFSON, Lennart; JANCZAK, Rajmund; OESTERLUNDH, Ingrid

    1992-01-01

    1 - Description of test facility: The FIX-II facility is a volume scaled 1:777 representation of a Swedish BWR with external pumps. The pressure vessel contains a 36 rod full length bundle and a spray condenser at the top to allow steady state operation. The downcomer, bypass channels and guide tube volumes are represented by external piping. The intact loop represents three of the four external reactor loops. The broken loop is constructed such that both guillotine breaks and split breaks may be simulated. The facility is equipped with ADS-simulation, but no ECCS injection are included. The FIX-II loop is also suited to investigate response of pump trips and MSIV closures in internal pump reactors. 2 - Description of test: Test 3025 simulates an intermediate size split break in one of the four main recirculation lines. The break area was 31 per cent of the scaled down pipe area of the reactor. The initial power of the 36-rod bundle was 3.38 MW, corresponding to the hot channel power of the reactor

  12. Therapeutic Endoscopic Ultrasonography: Intratumoral Injection for Pancreatic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Lawrence A. Shirley

    2013-01-01

    Full Text Available Pancreatic adenocarcinoma is an aggressive disease that has poor outcomes despite maximal traditional therapies. Thus, treatment of this cancer demands innovative strategies to be used in addition to standing therapies in order to provide new avenues of care. Here, we describe the technique of using endoscopic ultrasound in order to directly inject both novel and conventional therapies into pancreatic tumors. We detail the rationale behind this strategy and the many benefits it provides. We then describe our technique in detail, including our experience injecting the AdV-tk adenoviral vector to create an in situ vaccine effect.

  13. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic BZ

    International Nuclear Information System (INIS)

    Arpinar, V E; Muftuler, L T; Hamamura, M J; Degirmenci, E

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique, electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently, the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as IEC601. This protocol limits patient auxiliary currents to 100 µA for low frequencies. However, published MREIT studies have utilized currents 10–400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200 µA total injected current and tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul (1998 Elektrik 6 215–25) with Tikhonov regularization and the harmonic B Z proposed by Oh et al (2003 Magn. Reason. Med. 50 875–8). The reconstruction techniques were tested at both 200 µA and 5 mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200 µA total injected current into a cylindrical phantom generates only 14.7 µA current in imaging slice. Similarly, 5 mA total injected current results in 367 µA in imaging slice. Total acquisition

  14. Zinc injection helps reduce radiation field buildup in BWRs

    International Nuclear Information System (INIS)

    Wood, C.

    1991-01-01

    The injection of zinc into the reactor water of BWRs (Boiling Water Reactors) was a technique developed by General Electric (GE) and the Electric Power Research Institute (EPRI) to control the buildup of radiation fields from cobalt-60 on out-of-core piping. The presence of 5-10ppb zinc in the reactor water reduces the growth of oxide films on stainless steel surfaces, thereby reducing the number of sites available for the incorporation of cobalt; zinc also competes with cobalt for the sites. In September 1990, EPRI organized a workshop at the request of several US utilities to provide a forum to discuss experiences with zinc injection. The meeting focused on six main issues: the effect of zinc on radiation fields in normal water chemistry; the radiation buildup in hydrogen water chemistry, with and without zinc; the effects of zinc-65; the corrosion of fuel cladding and structural materials; the performance of zinc injection and monitoring equipment; and planning for zinc injection. (author)

  15. Start-up assist by magnetized plasma flow injection in TPE-RX reversed-field pinch

    Energy Technology Data Exchange (ETDEWEB)

    Asai, T. [College of Science and Technology, Nihon University, 1-8 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-8308 (Japan)]. E-mail: asai@phys.cst.nihon-u.ac.jp; Nagata, M. [Graduate School of Engineering, University of Hyogo, Himeji (Japan); Koguchi, H. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Hirano, Y. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Sakakita, H. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Yambe, K. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan); Kiyama, S. [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba (Japan)

    2006-11-15

    A reversed-field pinch (RFP) start-up assisted by a magnetized plasma flow injection was demonstrated for the first time on a TPE-RX machine. This sequence of experiments aimed to establish a new method of ionization, gas-fill and helicity injection in the start-up phase of an RFP. In this start-up method, magnetized and well-ionized plasma is formed by a magnetized coaxial plasma gun and injected into the torus chamber as an initial pre-ionized plasma for RFP formation. In the initial experiments, attenuated density pump-out and comparatively slow decay of the toroidal flux and plasma current were observed as evidence of its being an effective start-up method.

  16. Mechanical Weakening during Fluid Injection in Critically Stressed Sandstones with Acoustic Monitoring

    Science.gov (United States)

    David, C.; Dautriat, J. D.; Sarout, J.; Macault, R.; Bertauld, D.

    2014-12-01

    Water weakening is a well-known phenomenon which can lead to subsidence during the production of hydrocarbon reservoirs. The example of the Ekofisk oil field in the North Sea has been well documented for years. In order to assess water weakening effects in reservoir rocks, previous studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks saturated either with water or with inert fluids. However, little attention has been paid so far on the mechanical behaviour during the fluid injection stage, like in enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behaviour of Sherwood sandstone, a weakly-consolidated sandstone sampled at Ladram Bay in UK. In order to highlight possible weakening effects, water and inert oil have been injected into critically-loaded samples to assess their effect on strength and elastic properties and to derive the acoustic signature of the saturation front for each fluid. The specimens were instrumented with 16 ultrasonic P-wave transducers for both passive and active acoustic monitoring during fluid injection and loading. After conducting standard triaxial tests on three samples saturated with air, water and oil respectively, mechanical creep tests were conducted on dry samples loaded at 80% of the compressive strength of the dry rock. While these conditions are kept constant, a fluid is injected at the bottom end of the sample with a low back pressure (0.5 MPa) to minimize effective stress variations during injection. Both water and oil were used as the injected pore fluid in two experiments. As soon as the fluids start to flow into the samples, creep is taking place with a much higher strain rate for water injection compared to oil injection. A transition from secondary creep to tertiary creep is observed in the water injection test whereas in the oil injection test no significant creep acceleration is observed after one pore volume of oil was

  17. Additional heating experiments of FRC plasmas

    International Nuclear Information System (INIS)

    Okada, S.; Asai, T.; Kodera, F.; Kitano, K.; Suzuki, T.; Yamanaka, K.; Kanki, T.; Inomoto, M.; Yoshimura, S.; Okubo, M.; Sugimoto, S.; Ohi, S.; Goto, S.

    2001-01-01

    Additional heating experiments of neutral beam (NB) injection and application of low frequency wave on a plasma with extremely high averaged beta value of about 90% - a field reversed configuration (FRC) plasma - are carried out on the FRC Injection experiment (FIX) apparatus. These experiments are made possible by translating the FRC plasma produced in a formation region of a theta pinch to a confinement region in order to secure better accessibility to heating facilities and to control plasma density. By appropriate choice of injection geometry and the mirror ratio of the confinement region, the NB with the energy of 14keV and the current of 23A is enabled to be injected into the FRC in the solenoidal confining field of only 0.04-0.05T. Confinement is improved by this experiment. Ion heating is observed by the application of low frequency (80kHz ; about 1/4 of the ion gyro frequency) compressional wave. A shear wave, probably mode converted from the compressional wave, is detected to propagate axially. (author)

  18. Heat loss by helicity injection in spheromaks

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1994-01-01

    A model is presented for spheromak buildup and decay including thermal diffusivity associated with magnetic turbulence during helicity injection. It is shown that heat loss by magnetic turbulence scales more favorably than gyroBohm transport. Thus gyroBohm scaling for the proposed ignition experiment would be the conservative choice, though present experiments may be dominated by magnetic turbulence. Because of a change in boundary conditions when the gun is turned off, the model may account for the observed increase in electron temperature in CTX after turnoff

  19. Prevalence and correlates of neck injection among people who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Rafful, Claudia; Wagner, Karla D; Werb, Dan; González-Zúñiga, Patricia E; Verdugo, Silvia; Rangel, Gudelia; Strathdee, Steffanie A

    2015-11-01

    Injecting drugs in the neck has been related to adverse health conditions such as jugular vein thrombosis, deep neck infections, aneurysm, haematomas, airway obstruction, vocal cord paralysis and wound botulism, among others. We identified prevalence and correlates of neck injection among people who inject drugs (PWID) in Tijuana, Mexico. Beginning in 2011, PWID aged ≥18 years who injected drugs within the last month were recruited into a prospective cohort. At baseline and semi-annually, PWID completed interviewer-administered surveys soliciting data on drug-injecting practices. Logistic regression was used to identify predictors of injecting in the neck as the most frequent injection site at a single visit. Of 380 PWID, 35.3% injected in the neck at least once in the past 6 months, among whom 71.6% reported it as their most common injection site, the most common injecting site after the arms (47%). Controlling for age, years injecting and injecting frequency, injecting heroin and methamphetamine two or more times per day and having sought injection assistance were associated with injecting in the neck [adjusted odds ratios (AOR): 2.12; 95% confidence intervals (CI): 1.27-3.53 and AOR: 2.65; 95% CI: 1.52-4.53 respectively]. Injecting in the neck was very common among PWID in Tijuana and was associated with polydrug use and seeking injection assistance. Tailoring harm reduction education interventions for individuals who provide injection assistance ('hit doctors') may allow for the dissemination of safe injecting knowledge to reduce injection-related morbidity and mortality. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  20. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear