WorldWideScience

Sample records for ecc injection experiments

  1. Experiment data report for Semiscale Mod-1 tests S-05-2A and S-05-2B (alternate ECC injection tests)

    Energy Technology Data Exchange (ETDEWEB)

    Patton, Jr., M. L.; Collins, B. L.; Sackett, K. E.

    1977-04-01

    Recorded test data are presented for Tests S-05-2A and S-05-2B of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Tests S-05-2A and S-05-2B were conducted from initial conditions of 2263 psia and 543/sup 0/F and 2272 psia and 542/sup 0/F, respectively, to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the tests, cooling water was injected into the intact loop pump suction and broken loop cold leg to simulate emergency core coolant injection in a PWR with flow rates based on system volume scaling. For Test S-05-2A the intact loop pump speed was held constant throughout the test at the initial blowdown value. During Test S-05-2B the pump speed was reduced and stopped according to a predetermined coastdown schedule.

  2. Condensation during gravity driven ECC: Experiments with PACTEL

    Energy Technology Data Exchange (ETDEWEB)

    Munther, R.; Kalli, H. [Lappeenranta Univ. of Technology (Finland); Kouhia, J. [Technical Research Centre of Finland, Lappeenranta (Finland)

    1995-09-01

    This paper provides the results of the second series of gravity driven emergency core cooling (ECC) experiments with PACTEL (Parallel Channel Test Loop). The simulated accident was a small break loss-of-coolant accident (SBLOCA) with a break in a cold leg. The ECC flow was provided from a core makeup tank (CMT) located at a higher elevation than the main part of the primary system. The CMT was pressurized with pipings from the pressurizer and a cold leg. The tests indicated that steam condensation in the CMT can prevent ECC and lead to core uncovery.

  3. Conductivity probes for two-phase flow pattern determination during emergency core cooling (ECC) injection experiments at the COCO facility (PHDR)

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. (Research Centre Rossendorf, Dresden (Germany)); Kueppers, L. (Nuclear Research Centre Karlsruhe (Germany)); May, R. (Fraunhofer Inst. for Nondestructive Testing, Dept. Acoustical Methods for Nondestructive Testing, Evaluation and Quality Assurance, Dresden (Germany))

    1992-07-01

    The paper describes the use of needle-shaped conductivity probes for two-phase flow pattern determination during simulated ECC. The first results appear promising and the use of such probes as additional instrumentation can be envisaged in the future on power reactors, e.g. for the control of water level, once some improvements have been achieved, in particular regarding the stability of the probe. (orig.)

  4. Scaling of the direct ECC bypass during LBLOCA reflood phase with direct vessel injection system

    Energy Technology Data Exchange (ETDEWEB)

    Yun, B.J.; Kwon, T.S.; Song, C.H.; Jeong, J.J. [Korea Atomic Energy Research Inst., Taejon (Korea, Republic of); Cho, H.K.; Park, G.C. [Seoul National Univ., Dept. of Nuclear Engineering (Korea, Republic of)

    2001-07-01

    As one of the advanced design features of the Korea next generation reactor, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood period of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, a new scaling method, using time and velocity reduced linear scaling law, is suggested for the design of a scaled-down experimental facility to investigate the direct ECC bypass phenomena in PWR downcomer. (authors)

  5. Experiments of ECCS strainer blockage and debris settling in suppression pools

    Energy Technology Data Exchange (ETDEWEB)

    Hecker, G.E.; Johnson, A.B.; Murthy, P.; Padmanabhan

    1996-03-01

    If a rupture occurs in a nuclear power station pipe that leads to or from the reactor pressure vessel, the resultant Loss of Coolant Accident (LOCA) would initiate a chain of events involving complex flow phenomena. In a Boiling Water Reactor (BWR), the steam or liquid pipe break pressurizes the dry well, forcing the inert containment gases and steam through downcomers into the suppression pool, thoroughly mixing any particulates and pipe insulation debris carried with the gas flow to the pool. As the steam flow decreases, its unsteady condensation at the end of the downcomers (Condensation Oscillation and Chugging) produces continued water motion in the suppression pool and downcomers. During the blowdown event, high pressure and then low pressure pumps automatically start injecting water from the suppression pool into the reactor to keep its temperature under control. Proper functioning of this Emergency Core Cooling System (ECCS) is critical for the first 30 minutes or so, before operators have time to consider and align alternative sources of cooling water. A major concern for proper operation of the ECCS is the effect of fragmented insulation and plant particulates on the head loss at pump suction strainers. Sufficient loss could exceed the NPSH margin, causing cavitation with a resultant loss of pump capacity and longevity. The bead loss increases with the mass of debris accumulated on the pump strainers, which in turn is dependent on the debris concentration versus time in the suppression pool. This paper describes two sets of experiments that quantified the strainer head loss. One set of experiments considered the mixing and settling of fibrous insulation debris and fine iron oxide particles in the suppression pool during and after chugging. These tests used a reduced scale facility which duplicated the kinetic energy per unit water volume to define the concentration of the actual materials in the pool versus time.

  6. Pressure vessel fracture studies pertaining to a PWR LOCA-ECC thermal shock: experiments TSE-1 and TSE-2

    Energy Technology Data Exchange (ETDEWEB)

    Cheverton, R.D.

    1976-09-01

    The LOCA-ECC Thermal Shock Program was established to investigate the potential for flaw propagation in pressurized-water reactor (PWR) vessels during injection of emergency core coolant following a loss-of-coolant accident. Studies thus far have included fracture mechanics analyses of typical PWRs, the design and construction of a thermal shock test facility, determination of material properties for test specimens, and two thermal shock experiments with 0.53-m-OD (21-in.) by 0.15-m-wall (6-in.) cylindrical test specimens. The PWR calculations indicated that under some circumstances crack propagation could be expected and that experiments should be conducted for cracks that would have the potential for propagation at least halfway through the wall.

  7. ECCS flow verification to support transient analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, C.; Jacobs, R.H.; Ballard, J.E. [Commonwealth Edison Co., Chicago, IL (United States). Nuclear Fuel Services Dept.

    1994-12-31

    The RETRAN code has been used to develop a model of the Emergency Core Cooling System (ECCS). The model was developed in order to provide conservative injection flow data to be used in various LOCA and non-LOCA analyses and evaluations and to ensure that ECCS pump runout does not occur. The analyses were also needed in order to address a number of ECCS performance issues identified by Westinghouse. These issues include how previous analyses modeled miniflow, RCP seal injection, ECCS branch line resistance, pump suction boost during recirculation, injection line flow imbalances, and, of particular importance, ECCS flow measurement inaccuracies. In turn, these issues directly impact pump runout concerns, Technical Specification verification, and ECCS injection flow during transient conditions. The RETRAN ECCS model has proven to be quite versatile, easy to use, and requires only minimal information about the physical construction and performance of the ECCS system.

  8. Pressure vessel fracture studies pertaining to a PWR LOCA-ECC thermal shock: experiments TSE-3 and TSE-4 and update of TSE-1 and TSE-2 analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cheverton, R.D.; Bolt, S.E.

    1977-11-04

    The LOCA-ECC Thermal Shock Program was established to investigate the potential for flaw propagation in pressurized-water reactor (PWR) vessels during injection of emergency core coolant following a loss-of-coolant accident. Studies thus far have included fracture mechanics analyses of typical PWRs, the design and construction of a thermal shock test facility, determination of material properties for test specimens, and four thermal shock experiments with 0.53-m-OD (21-in.) by 0.15-m-wall (6-in.) cylindrical test specimens. In the first experiment, initiation was not expected and did not occur, although there was a small amount of subcritical crack growth. In the second experiment, initiation of a semicircular flaw took place as expected; the final length along the surface was about four times the initial length, but there was no radial growth. The third and fourth experiments were similar, and the long axial flaw initiated in good agreement with predictions.

  9. [3 1/2 years experiences with ECCE with tunnel incision].

    Science.gov (United States)

    Häberle, H; Anders, N; Antoni, H J; Pham, D T; Wollensak, J

    1997-01-01

    Since January 1992 planned extracapsular cataract extraction (ECCE) is performed routinely with the no-stitch technique at our clinic. To minimize surgically induced astigmatism further, modified wound constructions for planned ECCE with on 1.1-mm tunnel width were evaluated. The follow-up time was up to 3 years postoperatively. For 250 eyes wound closure was performed prospectively either sutureless (n = 70), with a single perpendicular suture (n = 100) or cross sutures (n = 40) at the 12 o'clock position or sutureless in the temporal position (n = 40). The complication rate was 4% (filtering bleb, iris prolapse or transient hypotonia). There were no wound ruptures, but once endophthalmitis was observed. Late mean astigmatism after up to 3 years follow-up for vertical incision was 2.05 +/- 1.16 D (1.01 +/- 0.96 D preoperatively) for sutureless wound closure, 1.63 +/- 1.08 D (0.86 +/- 0.95 D) for perpendicular and 1.76 +/- 0.88 D (0.73 +/- 0.55 D) for cross-sutures. A temporal incision resulted in 0.78 +/- 0.52 D (1.0 +/- 0.69 D) of astigmatism and was only performed on eyes with against the rule astigmatism preoperatively. Surgically induced astigmatism was stabilized early. For with the rule astigmatism preoperatively, a 12 o'clock incision with a perpendicular single suture is recommended and for against the rule astigmatism, a temporal incision.

  10. [Patient's pain feeling and surgeon's comfort--ECCE versus phacoemulsification].

    Science.gov (United States)

    Kałuzny, Jakub J; Eliks, Iwona; Mierzejewski, Andrzej; Kałuzny, Bartłomiej

    2004-01-01

    To compare patient's pain and surgeon's comfort during ECCE performed under retrobulbar anesthesia and phacoemulsification under topical anesthesia. 120 patients scheduled for planned routine cataract extraction were divided in 2 groups: group 1-60 eyes, ECCE under retrobulbar anesthesia and group II-60 eyes, phacoemulsification under topical anesthesia. Immediately after operation patients were asked, to answer questions about their feeling during surgery. Simultaneously, the surgeon filled up the questionnaire, concerning patients behavior during the entire procedure. Statistically significant higher level of pain was reported in group I (ECCE). The most painful moment of the procedure was retrobulbar injection. During surgery pain feeling in both groups was similar. Both types of anesthesia provided very good level of surgeon's comfort. The longer operation, the higher level of pain and lower surgeon's comfort were reported in both groups. Patients having ECCE performed under retrobulbar anesthesia reported more pain comparing to phacoemulsification under topical anesthesia. Both anesthesia methods provided high level of surgeon's comfort.

  11. Simulation of a large break loss of coolant (LBLOCA), without actuation of the emergency injection systems (ECCS) for a BWR-5; Simulacion de un escenario de perdida de refrigerante grande (LBLOCA), sin actuacion de los sistemas de inyeccion de emergencia (ECCS) para un reactor BWR-5

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Lopez M, R., E-mail: jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    In this paper the analysis of scenario for the loss of coolant case was realized with break at the bottom of a recirculation loop of a BWR-5 with containment type Mark II and a thermal power of 2317 MWt considering that not have coolant injection. This in order to observe the speed of progression of the accident, the phenomenology of the scenario, the time to reach the limit pressure of containment venting and the amount of radionuclides released into the environment. This simulation was performed using the MELCOR code version 2.1. The scenario posits a break in one of the shear recirculation loops. The emergency core cooling system (ECCS) and the reactor core isolation cooling (Rcic) have not credit throughout the event, which allowed achieve greater severity on scenario. The venting of the primary containment was conducted via valve of 30 inches instead of the line of 24 inches of wet well, this in order to have a larger area of exhaust of fission products directly to the reactor building. The venting took place when the pressure in the primary containment reached the 4.5 kg/cm{sup 2} and remained open for the rest of the scenario to maximize the amount released of radionuclides to the atmosphere. The safety relief valves were considered functional they do not present mechanical failure or limit their ability to release pressure due to the large number of performances in safety mode. The results of the analysis covers about 48 hours, time at which the accident evolution was observed; behavior of level, pressure in the vessel and the fuel temperature profile was analyzed. For progression of the scenario outside the vessel, the pressure and temperature of the primary containment, level and temperature of the suppression pool, the hydrogen accumulation in the container and the radionuclides mass released into the atmosphere were analyzed. (Author)

  12. Extrusion of ECC-Material

    DEFF Research Database (Denmark)

    Stang, Henrik; Li, Victor C.

    1999-01-01

    in recent years at Department of Civil and Envirionmetal Engineering, University of Michigan. These materials have been developed with the special aim of producing high performance , strain hardening materials with low volume concentrations of short fibers in a cementitious material.ECC material spcimens...... have until now been produced by traditional casting processes. In the present paper results from a recent collaborative reserach project are documented - demonstrating that ECC materials can be extruded in the process referred to above.......An extrusion process especially designed for extrusion of pipes made from fiber reinforced cementitious materials has been developed at Department of Structural Engineering and Materials at the Technical University of DenmarkEngineered Cementitious Composite (ECC) materials have been developed...

  13. Dense Plasma Injection Experiment at MCX

    Science.gov (United States)

    Uzun-Kaymak, I.; Messer, S.; Bomgardner, R.; Case, A.; Clary, R.; Ellis, R.; Elton, R.; Hassam, A.; Teodorescu, C.; Witherspoon, D.; Young, W.

    2009-09-01

    We present preliminary results of the High Density Plasma Injection Experiment at the Maryland Centrifugal Experiment (MCX). HyperV Technologies Corp. has designed, built, and installed a prototype coaxial gun to drive rotation in MCX. This gun has been designed to avoid the blow-by instability via a combination of electrode shaping and a tailored plasma armature. An array of diagnostics indicates the gun is capable of plasma jets with a mass of 160 μg at 70 km/s with an average plasma density above 1015 cm-3. Preliminary measurements are underway at MCX to understand the penetration of the plasma jet through the MCX magnetic field and the momentum transfer from the jet to the MCX plasma. Data will be presented for a wide range of MCX field parameters, and the prospects for future injection experiments will be evaluated.

  14. Experimental Study of the APR+ Direct ECC Bypass in the Air-water Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kihwan; Choi, Hae-Seob; Park, Kil-won; Kwon, Tae-Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The APR+ is an improved Korean Nuclear Power Reactor, which has been developed as a two loop evolutionary PWR (Pressure Water Reactor) with a number of advanced design features to enhance safety based on the APR-1400 technology. The emergency core cooling system (ECC) of the APR+ is different with that of the APR-1400, though the APR+ adopted a direct vessel injection (DVI) system which is the same design features of the APR-14000. The main difference of the DVI+ is the emergency core barrel duct (ECBD) which is designed to increase the amount of the injection water to the core region. The performance of the DVI system has been an important issues for past decades, and many researchers have studied the related thermal-hydraulic technical issues such as the ECC bypass fraction, the steam condensation effect, temperature distribution, sub-cooling margin, and etc. However, the previous research cannot be directly applicable to the APR+ owing to the unique features of the DVI+. The current study will elaborate on the experimental evaluation of the direct ECC bypass performance. The 1/5 ECC bypass test facility which is designed with a linearly reduced 1/5 scale referring to the APR+ was used to investigate the effect of the DVI+ injection nozzle location and the broken cold leg velocity on the direct ECC bypass fraction. However, air is used as a working fluid to simulate the steam flow induced from the broken cold leg, and thus, the direct contact condensation effect is not considered in this study. Experimental study for the direct ECC bypass phenomena has been carryout out with various the injection mode and air velocity conditions. The tests were performed in the 1/5 scale ECC bypass test facility, and the test condition was defined using a scaling law referring to the APR+ reactor. Test results showed that the direct ECC bypass fraction was greatly enhanced compared with the reference test (w/o ECBD)

  15. 老年重症瓣膜病手术的体外循环管理经验%ECC Management Experience in Aged Patients With Severe Valvular Disease

    Institute of Scientific and Technical Information of China (English)

    黄东娇; 李传在

    2015-01-01

    Objective To analyze experience of the elderly with severe valvular disease bypass ECC Management.MethodsFrom January 2011 to May 2015, a total of 132 cases over the age of 60,underwent open heart surgery. ECC methods were analyzed and summarized.Results Al 132 patients were operated successfuly,and there was no operative death. Two cases of early postoperative death due to multiple organ failure.Conclusion The way of open heart surgery in elderly patients treated with severe valvular can obtain a more significant effect.%目的:分析老年重症瓣膜病手术的体外循环经验。方法从2011年1月~2015年5月,共治疗132例60岁以上的老年瓣膜病患者,均进行心内直视手术治疗,对体外循环管理(ECC)方法进行分析总结。结果本组132例患者手术均获得成功,无手术死亡,术后早期死亡2例,原因为多脏器功能衰竭。结论采用心内直视手术方式对老年重症瓣膜病患者进行治疗,加强对体外循环管理的重视可取得理想的效果。

  16. ECCE 41. konverents Tallinnas / Urmo Kala

    Index Scriptorium Estoniae

    Kala, Urmo

    2005-01-01

    9.-11. juunini 2005. a. toimus Tallinnas Eesti Ehitusinseneride Liidu korraldusel Euroopa ehitusinseneride liitude ühenduse (ECCE) 41. konverents. ECCE on nõuandvaks organiks Euroopa Liidu struktuuridele ja liikmesriikide valitsustele ehituspoliitika, ehitusstandardite, ehitusalase hariduse, ehituse ohutuse ja kvaliteedinõuete väljatöötamisel

  17. ECC Ozonesonde Calibration and Observations: Satellite Validation

    Science.gov (United States)

    Schmidlin, Francis J.; Zukor, Dorothy (Technical Monitor)

    2001-01-01

    The reliability of the Electrochemical Concentration Cell (ECC) ozonesonde depends on the care exercised in preparing the instrument for use. Although the ECC can be quickly prepared and flown, generally within less then one day if necessary, it is best to prepare the instrument at least one week prior to use, and as our tests have confirmed even 2-3 weeks prior to use may actually be better. There are a number of factors that must be considered when preparing an ECC. These basically are the pump efficiency, volumetric flow rate, temperature of the air entering the pump, and the background current. Also of importance is the concentration of the potassium iodide solution. Tests conducted at Wallops Island (38 N) has enabled us to identify potential problem areas and ways to avoid them. The calibration and pre-flight preparation methods will be discussed. The method of calibrating the ECC also is used at Ascension Island (8 S) and Natal, Brazil (5 S). Comparisons between vertical profiles of the ECC instrument and satellites will be reviewed as well as comparison with ground based instruments, such as, the Dobson Spectrophotometer and hand held Microtops photometers.

  18. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  19. Flux-Level Transit Injection Experiments with NASA Pleiades Supercomputer

    Science.gov (United States)

    Li, Jie; Burke, Christopher J.; Catanzarite, Joseph; Seader, Shawn; Haas, Michael R.; Batalha, Natalie; Henze, Christopher; Christiansen, Jessie; Kepler Project, NASA Advanced Supercomputing Division

    2016-06-01

    Flux-Level Transit Injection (FLTI) experiments are executed with NASA's Pleiades supercomputer for the Kepler Mission. The latest release (9.3, January 2016) of the Kepler Science Operations Center Pipeline is used in the FLTI experiments. Their purpose is to validate the Analytic Completeness Model (ACM), which can be computed for all Kepler target stars, thereby enabling exoplanet occurrence rate studies. Pleiades, a facility of NASA's Advanced Supercomputing Division, is one of the world's most powerful supercomputers and represents NASA's state-of-the-art technology. We discuss the details of implementing the FLTI experiments on the Pleiades supercomputer. For example, taking into account that ~16 injections are generated by one core of the Pleiades processors in an hour, the “shallow” FLTI experiment, in which ~2000 injections are required per target star, can be done for 16% of all Kepler target stars in about 200 hours. Stripping down the transit search to bare bones, i.e. only searching adjacent high/low periods at high/low pulse durations, makes the computationally intensive FLTI experiments affordable. The design of the FLTI experiments and the analysis of the resulting data are presented in “Validating an Analytic Completeness Model for Kepler Target Stars Based on Flux-level Transit Injection Experiments” by Catanzarite et al. (#2494058).Kepler was selected as the 10th mission of the Discovery Program. Funding for the Kepler Mission has been provided by the NASA Science Mission Directorate.

  20. Laboratory Experiments on Enhanced Oil Recovery with Nitrogen Injection

    Directory of Open Access Journals (Sweden)

    S. Siregar

    2007-05-01

    Full Text Available Based on previous studies, nitrogen injection could recover oil up to 45-90% of initial reserves. Although this method has a very good ability to produce oil, sometimes the operation pressure is higher than leak off formation pressure. In this study, operation pressure used a low pressure to solve this problem under immiscible process. Objective of this study is to determine the effect of injection pressure and displacement rate on oil recovery performance of continuous one dimensional nitrogen gas injection with a slim tube apparatus. The effect of nitrogen gas-oil contact on the gas composition was investigated using Gas Chromatograph Mass Spectrometer apparatus. In the experiments, nitrogen gas was injected into an oil sample of 38.5 oAPI gravity at various rates: 20 cc/hr, 30 cc/hr and 36.66/hr under 1500 psi pressure, and then at 20 cc/hr undr 2500 psi pressure. The results showed that an increase in injection rate increased oil recovery factor. The recovery factor lies between 40-54% of original oil in place. Gas analysis before injection and at the injection outlet showed a change of composition. when oil was contacted by nitrogen, indicating that some molecular mass transfer had taken place.

  1. Geothermal injection treatment: process chemistry, field experiences, and design options

    Energy Technology Data Exchange (ETDEWEB)

    Kindle, C.H.; Mercer, B.W.; Elmore, R.P.; Blair, S.C.; Myers, D.A.

    1984-09-01

    The successful development of geothermal reservoirs to generate electric power will require the injection disposal of approximately 700,000 gal/h (2.6 x 10/sup 6/ 1/h) of heat-depleted brine for every 50,000 kW of generating capacity. To maintain injectability, the spent brine must be compatible with the receiving formation. The factors that influence this brine/formation compatibility and tests to quantify them are discussed in this report. Some form of treatment will be necessary prior to injection for most situations; the process chemistry involved to avoid and/or accelerate the formation of precipitate particles is also discussed. The treatment processes, either avoidance or controlled precipitation approaches, are described in terms of their principles and demonstrated applications in the geothermal field and, when such experience is limited, in other industrial use. Monitoring techniques for tracking particulate growth, the effect of process parameters on corrosion and well injectability are presented. Examples of brine injection, preinjection treatment, and recovery from injectivity loss are examined and related to the aspects listed above.

  2. Neutral Beam Injection Experiments in the HL-1M Tokamak

    Institute of Scientific and Technical Information of China (English)

    严龙文; 雷光玖; 钟光武; 江涛; 周艳; 姜韶风; 丁玄同; 周才品; 刘永

    2003-01-01

    Neutral beam injection (NBI) experiments have been carried out with two operation modes of a bucket ion source in the HL-1M tokamak. During the first mode, more than 30% rise in ion temperature above the Ohmic level is routinely achieved after NBI power about 0. 5 MW is injected. Ion temperature only increases 20-30% for the second operation mode, which is often limited by current termination. The heating effects of the NBI have been analysed experimentally and theoretically. The performance of the NBI system is well described.

  3. Attacks and countermeasures on AES and ECC

    DEFF Research Database (Denmark)

    Tange, Henrik; Andersen, Birger

    2013-01-01

    AES (Advanced Encryption Standard) is widely used in LTE and Wi-Fi communication systems. AES has recently been exposed to new attacks which have questioned the overall security of AES. The newest attack is a so called biclique attack, which is using the fact that the content of the state array...... side-channels attacks can be applied to ECC. This paper reflects an ongoing research in the field of countermeasures against the attacks mentioned above....

  4. Analysis of system thermal hydraulic responses for passive safety injection experiment at ROSA-IV Large Scale Test Facility. Using JAERI modified version of RELAP5/MOD2 code

    Energy Technology Data Exchange (ETDEWEB)

    Asaka, Hideaki; Yonomoto, Taisuke; Kukita, Yutaka (Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment)

    1994-12-01

    An experiment was conducted at the ROSA-IV/Large Scale Test Facility (LSTF) on the performance of a gravity-driven emergency core coolant (ECC) injection system attached to a pressurized water reactor (PWR). Such a gravity-driven injection system, though not used in the current-generation PWRs, is proposed for future reactor designs. The experiment was performed to identify key phenomena peculiar to the operation of a gravity injection system and to provide data base for code assessment against such phenomena. The simulated injection system consisted of a tank which was initially filled with cold water of the same pressure as the primary system. The tank was connected at its top and bottom, respectively, to the cold leg and the vessel downcomer. The injection into the downcomer was driven primarily by the static head difference between the cold water in the tank and the hot water in the pressure balance line (PBL) connecting the cold leg to the tank top. The injection flow was oscillatory after the flow through the PBL became two-phase flow. The experiment was post-test analyzed using a JAERI modified version of the RELAP5/MOD2 code. The code calculation simulated reasonably well the system responses observed in the experiment, and suggested that the oscillations in the injection flow was caused by oscillatory liquid holdup in the PBL connecting the cold leg to tank top. (author).

  5. eccCL: parallelized GPU implementation of Ensemble Classifier Chains.

    Science.gov (United States)

    Riemenschneider, Mona; Herbst, Alexander; Rasch, Ari; Gorlatch, Sergei; Heider, Dominik

    2017-08-17

    Multi-label classification has recently gained great attention in diverse fields of research, e.g., in biomedical application such as protein function prediction or drug resistance testing in HIV. In this context, the concept of Classifier Chains has been shown to improve prediction accuracy, especially when applied as Ensemble Classifier Chains. However, these techniques lack computational efficiency when applied on large amounts of data, e.g., derived from next-generation sequencing experiments. By adapting algorithms for the use of graphics processing units, computational efficiency can be greatly improved due to parallelization of computations. Here, we provide a parallelized and optimized graphics processing unit implementation (eccCL) of Classifier Chains and Ensemble Classifier Chains. Additionally to the OpenCL implementation, we provide an R-Package with an easy to use R-interface for parallelized graphics processing unit usage. eccCL is a handy implementation of Classifier Chains on GPUs, which is able to process up to over 25,000 instances per second, and thus can be used efficiently in high-throughput experiments. The software is available at http://www.heiderlab.de .

  6. Experiences with ACE inhibitors early after acute myocardial infarction. Rationale and design of the German Multicenter Study on the Effects of Captopril on Cardiopulmonary Exercise parameters post myocardial infarction (ECCE).

    Science.gov (United States)

    Kleber, F X; Reindl, I; Wenzel, M; Rodewyk, P; Beil, S; Kosloswki, B; Doering, W; Sabin, G V; Hinzmann, S; Winter, U J

    1993-12-01

    Left ventricular damage by necrosis of myocardial tissue can lead to compromise of left ventricular function, to left ventricular volume increase and ultimately to development of heart failure. This sequence in the pathophysiology has been shown to be blunted by ACE inhibitors. Volume increase, however, can also be helpful in restoring stroke volume and ameliorate elevation of filling pressures. Furthermore, very early institution of ACE inhibition has failed to improve short-term mortality after myocardial infarction in one large trial. The aim of the ECCE trial therefore is, to investigate the early effects of the ACE inhibitor captopril on compromise of exercise capacity, thought to be a first measurable sign of developing heart failure. The ECCE trial is a randomized, seven-center investigation, studying the effects of ACE inhibition on oxygen uptake in a double blind, placebo controlled design in a group of 204 patients. Sample size was calculated on the basis of a pilot trial. The study design and first not unblinded data of 104 patients are presented. The population consists of predominantly male patients with mostly first myocardial infarction. They were admitted to hospital within five hours of onset of chest pain. End-diastolic volumes were normal, but ejection fraction was moderately compromised. ACE inhibition was started after the first day, but within 72 hours of onset of chest pain. After four and after twelve weeks, oxygen uptake was considerably below expected values and one third of the patients had severe compromise of exercise capacity.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Noise-based Stego-ECC

    Directory of Open Access Journals (Sweden)

    Rahardjo Budi

    2014-03-01

    Full Text Available A novel method of inserting noise into stream of ciphered text is proposed. The goal of inserting noise is to increase the level of uncertainty, thus making it harder for an attacker to detect data and noise. This form of steganography is implemented using Elliptic Curve Cryptography (ECC. The process of embedding the noise to the message in the encryption process and removing the noise from the message in the decryption process is proposed in this work by modifying ElGamal to allow auto detection of data and noise.

  8. Modeling of Carbon Migration During JET Injection Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Strachan, J. D.; Likonen, J.; Coad, P.; Rubel, M.; Widdowson, A.; Airila, M.; Andrew, P.; Brezinsek, S.; Corrigan, G.; Esser, H. G.; Jachmich, S.; Kallenbach, A.; Kirschner, A.; Kreter, A.; Matthews, G. F.; Philipps, V.; Pitts, R. A.; Spence, J.; Stamp, M.; Wiesen, S.

    2008-10-15

    JET has performed two dedicated carbon migration experiments on the final run day of separate campaigns (2001 and 2004) using {sup 13}CH{sub 4} methane injected into repeated discharges. The EDGE2D/NIMBUS code modelled the carbon migration in both experiments. This paper describes this modelling and identifies a number of important migration pathways: (1) deposition and erosion near the injection location, (2) migration through the main chamber SOL, (3) migration through the private flux region aided by E x B drifts, and (4) neutral migration originating near the strike points. In H-Mode, type I ELMs are calculated to influence the migration by enhancing erosion during the ELM peak and increasing the long-range migration immediately following the ELM. The erosion/re-deposition cycle along the outer target leads to a multistep migration of {sup 13}C towards the separatrix which is called 'walking'. This walking created carbon neutrals at the outer strike point and led to {sup 13}C deposition in the private flux region. Although several migration pathways have been identified, quantitative analyses are hindered by experimental uncertainty in divertor leakage, and the lack of measurements at locations such as gaps and shadowed regions.

  9. Development of system performance verification test technology for KNGR; optimal design and performance test for DVI of ECC water

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kune Yull; Yoon, Sang Hyuk; Noh, Sang Woo [Seoul National University, Seoul (Korea); Lee, Il Suk [Kyung Hee University, Seoul (Korea)

    2002-03-01

    In this study, we completed the works for the specific thermal-hydraulic phenomena in the reactor downcomer during a operation of DVI system. The choices for a filed of study are focused on the general abilities and flow behaviors of DVI system in the downcomer, and we intended to be able to suggest the applicable data to the APR1400 for the inclusive, actual, various area from the phenomena caused by the ECC injection to the code analysis of steam flow, ECC bypass and the downcomer water level decrease. 28 refs., 77 figs., 14 tabs. (Author)

  10. ECC over RSA for Asymmetric Encryption-A Review

    Directory of Open Access Journals (Sweden)

    Kamlesh Gupta

    2011-05-01

    Full Text Available Cryptography is used to transmit the data securely in open network. This paper gives the survey of Elliptic Curve Cryptosystem (ECC used in many applications. ECC is a when compared to RSA and discrete logarithm systems, is a better option for the future. For this reason ECC is such an excellent choice for doing asymmetric cryptography in portable devices right now. The smaller ECC keys it turn makes the cryptographic operations that must be performed by the communicating devices to be embedded into considerably smaller hardware, so that software applications may complete cryptographic operations with fewer processor cycles, and operations can be performed much faster, while still retaining equivalent security. This means, in turn, reduced power consumption, less space consumed on the printed circuit board, and software applications that run more rapidly make lower memory demands. In brief, for communication using smaller devices and asymmetric cryptosystem we need ECC.

  11. ECCE Toolkit: Prototyping Sensor-Based Interaction

    Science.gov (United States)

    Bellucci, Andrea; Aedo, Ignacio; Díaz, Paloma

    2017-01-01

    Building and exploring physical user interfaces requires high technical skills and hours of specialized work. The behavior of multiple devices with heterogeneous input/output channels and connectivity has to be programmed in a context where not only the software interface matters, but also the hardware components are critical (e.g., sensors and actuators). Prototyping physical interaction is hindered by the challenges of: (1) programming interactions among physical sensors/actuators and digital interfaces; (2) implementing functionality for different platforms in different programming languages; and (3) building custom electronic-incorporated objects. We present ECCE (Entities, Components, Couplings and Ecosystems), a toolkit for non-programmers that copes with these issues by abstracting from low-level implementations, thus lowering the complexity of prototyping small-scale, sensor-based physical interfaces to support the design process. A user evaluation provides insights and use cases of the kind of applications that can be developed with the toolkit. PMID:28241502

  12. An ECC-Based Blind Signature Scheme

    Directory of Open Access Journals (Sweden)

    Fuh-Gwo Jeng

    2010-08-01

    Full Text Available Cryptography is increasingly applied to the E-commerce world, especially to the untraceable payment system and the electronic voting system. Protocols for these systems strongly require the anonymous digital signature property, and thus a blind signature strategy is the answer to it. Chaum stated that every blind signature protocol should hold two fundamental properties, blindness and intractableness. All blind signature schemes proposed previously almost are based on the integer factorization problems, discrete logarithm problems, or the quadratic residues, which are shown by Lee et al. that none of the schemes is able to meet the two fundamental properties above. Therefore, an ECC-based blind signature scheme that possesses both the above properties is proposed in this paper.

  13. ECCE Toolkit: Prototyping Sensor-Based Interaction.

    Science.gov (United States)

    Bellucci, Andrea; Aedo, Ignacio; Díaz, Paloma

    2017-02-23

    Building and exploring physical user interfaces requires high technical skills and hours of specialized work. The behavior of multiple devices with heterogeneous input/output channels and connectivity has to be programmed in a context where not only the software interface matters, but also the hardware components are critical (e.g., sensors and actuators). Prototyping physical interaction is hindered by the challenges of: (1) programming interactions among physical sensors/actuators and digital interfaces; (2) implementing functionality for different platforms in different programming languages; and (3) building custom electronic-incorporated objects. We present ECCE (Entities, Components, Couplings and Ecosystems), a toolkit for non-programmers that copes with these issues by abstracting from low-level implementations, thus lowering the complexity of prototyping small-scale, sensor-based physical interfaces to support the design process. A user evaluation provides insights and use cases of the kind of applications that can be developed with the toolkit.

  14. ECCE Toolkit: Prototyping Sensor-Based Interaction

    Directory of Open Access Journals (Sweden)

    Andrea Bellucci

    2017-02-01

    Full Text Available Building and exploring physical user interfaces requires high technical skills and hours of specialized work. The behavior of multiple devices with heterogeneous input/output channels and connectivity has to be programmed in a context where not only the software interface matters, but also the hardware components are critical (e.g., sensors and actuators. Prototyping physical interaction is hindered by the challenges of: (1 programming interactions among physical sensors/actuators and digital interfaces; (2 implementing functionality for different platforms in different programming languages; and (3 building custom electronic-incorporated objects. We present ECCE (Entities, Components, Couplings and Ecosystems, a toolkit for non-programmers that copes with these issues by abstracting from low-level implementations, thus lowering the complexity of prototyping small-scale, sensor-based physical interfaces to support the design process. A user evaluation provides insights and use cases of the kind of applications that can be developed with the toolkit.

  15. IIST small break LOCA experiments with passive core cooling injection

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.-J. [Nuclear Engineering Division, Institute of Nuclear Energy Research, P.O. Box 3-3, Longtan, Taiwan 325 (China)]. E-mail cjchang@iner.gov.tw; Lee, C.-H. [Nuclear Engineering Division, Institute of Nuclear Energy Research, P.O. Box 3-3, Longtan, Taiwan 325 (China); Hong, W.-T. [Nuclear Engineering Division, Institute of Nuclear Energy Research, P.O. Box 3-3, Longtan, Taiwan 325 (China); Wang, Lance L.C. [Lungmen Project Quality Supervisory and Directory Committee, Taiwan Power Company, 62, Yeh-Hai St., Kung-Liao, Taipei County, Taiwan 238 (China)

    2006-01-15

    The purpose of this study is to evaluate the performance of a passive core cooling system (PCCS) with passive injection during the cold-leg small break loss-of-coolant accidents (SBLOCAs) experiments conducted at the Institute of Nuclear Energy Research (INER) Integral System Test (IIST) facility. Four tests were performed simulating break sizes of 0.2-2% (approximately corresponding to 1.25-4'' breaks for a referenced nuclear power plant) at cold-leg for assessing the PCCS capability in accident management. The key thermal-hydraulic phenomena to core heat removal for PCCS are observed and discussed. The experimental results show that the PCCS has successfully provided a continuous removal of core heat and a long term core cooling can be reached for all cases of SBLOCA.

  16. Computer modeling of a three-dimensional steam injection experiment

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, S.; Castanier, L.M. [Stanford Univ., CA (United States). Petroleum Research Inst.

    1993-08-01

    The experimental results and CT scans obtained during a steam-flooding experiment with the SUPRI 3-D steam injection laboratory model are compared with the results obtained from a numerical simulator for the same experiment. Simulation studies were carried out using the STARS (Steam and Additives Reservoir Simulator) compositional simulator. The saturation and temperature distributions obtained and heat-loss rates measured in the experimental model at different stages of steam-flooding were compared with those calculated from the numerical simulator. There is a fairly good agreement between the experimental results and the simulator output. However, the experimental scans show a greater degree of gravity override than that obtained with the simulator for the same heat-loss rates. Symmetric sides of the experimental 5-spot show asymmetric heat-loss rates contrary to theory and simulator results. Some utility programs have been written for extracting, processing and outputting the required grid data from the STARS simulator. These are general in nature and can be useful for other STARS users.

  17. Shear behavior of reinforced Engineered Cementitious Composites (ECC) beams

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2010-01-01

    This paper describes an experimental investigation of the shear behavior of beams consisting of steel reinforced Engineered Cementitious Composites (ECC). Based on the strain hardening and multiple cracking behavior of ECC, this study investigates the extent to which ECC can improve the shear...... randomly distributed PVA (polyvinyl alcohol) fiber beams with different stirrup spacing and reinforced concrete (RC) beams for comparison. Displacement and strain measurements taken using the ARAMIS photogrammetric data acquisition system by means of processing at high frame rate captured images of applied...

  18. Experiments on Plasma Injection into a Centrifugally Confined System

    Science.gov (United States)

    Messer, S.; Bomgardner, R.; Brockington, S.; Case, A.; Witherspoon, F. D.; Uzun-Kaymak, I.; Elton, R.; Young, W.; Teodorescu, C.; Morales, C. H.; Ellis, R. F.

    2009-11-01

    We describe the cross-field injection of plasma into a centrifugally-confined system. Two different types of plasma railgun have been installed on the Maryland Centrifugal Experiment (MCX) in an attempt to drive that plasma's rotation. The initial gun was a coaxial device designed to mitigate the blowby instability. The second one was a MiniRailgun with a rectangular bore oriented so that the MCX magnetic field augments the railgun's internal magnetic field. Tests at HyperV indicate this MiniRailgun reaches much higher densities than the original gun, although muzzle velocity is slightly reduced. We discuss the impact of these guns on MCX for various conditions. Initial results show that even for a 2 kG field, firing the MiniRailgun modifies oscillations of the MCX diamagnetic loops and can impact the core current and voltage. The gun also has a noticeable impact on MCX microwave emissions. These observations suggest plasma enters the MCX system. We also compare diagnostic data collected separately from MCX for these and other guns, focussing primarily on magnetic measurements.

  19. Overdose experiences among injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Wood Evan

    2010-05-01

    Full Text Available Abstract Background Although previous studies have identified high levels of drug-related harm in Thailand, little is known about illicit drug overdose experiences among Thai drug users. We sought to investigate non-fatal overdose experiences and responses to overdose among a community-recruited sample of injection drug users (IDU in Bangkok, Thailand. Methods Data for these analyses came from IDU participating in the Mit Sampan Community Research Project. The primary outcome of interest was a self-reported history of non-fatal overdose. We calculated the prevalence of past overdose and estimated its relationship with individual, drug-using, social, and structural factors using multivariate logistic regression. We also assessed the prevalence of ever witnessing an overdose and patterns of response to overdose. Results These analyses included 252 individuals; their median age was 36.5 years (IQR: 29.0 - 44.0 and 66 (26.2% were female. A history of non-fatal overdose was reported by 75 (29.8% participants. In a multivariate model, reporting a history of overdose was independently associated with a history of incarceration (Adjusted Odds Ratio [AOR] = 3.83, 95% Confidence Interval [CI]: 1.52 - 9.65, p = 0.004 and reporting use of drugs in combination (AOR = 2.48, 95% CI: 1.16 - 5.33, p = 0.019. A majority (67.9% reported a history of witnessing an overdose; most reported responding to the most recent overdose using first aid (79.5%. Conclusions Experiencing and witnessing an overdose were common in this sample of Thai IDU. These findings support the need for increased provision of evidence-based responses to overdose including peer-based overdose interventions.

  20. Tangential and Vertical Compact Torus Injection Experiments on the STOR-M Tokamak

    Institute of Scientific and Technical Information of China (English)

    Xiao Chijin; Liu D.; S. Livingstone; A. K. Singh; E. Zhang; A. Hirose

    2005-01-01

    This paper describes the setup and results of compact torus (CT) injection experiments on the STOR-M tokamak. Tangential CT injection into STOR-M induced H-mode-like phenomena including doubling the electron density, reduction in the Ha radiation level, suppression of the floating potential fluctuations, suppression of the m = 2 Mirnov oscillations, and increase in the global energy confinement time. Experimental setup, bench-test results, and some preliminary injection data for vertical CT injection experiments on STOR-M will be shown. In addition, numerical simulations of the CT trajectories in tokamak discharges for both tangential and vertical injection geometries will be discussed.

  1. Present soil data for the ECCES-program system. [ECCES - Environmental Calculations of Consequences of Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, P.B.

    1986-01-01

    This is a status report that presents area and soil data, soil characteristics and input data used in the ECCES-program system for Danish arable soils. Input of ions to the upper soil layer with rain, fertilizer and lime are described together with the parameters used to describe the properties of different soil types. Together with a series of other reports, this report forms part of the description of the ECCES-model developed at Risoe National Laboratory.

  2. Progestogen-only injectable contraceptive: Experience of women in ...

    African Journals Online (AJOL)

    menstrual pattern are a well known side effect of this effective contraceptive method. .... For most teenagers requesting contraceptive, ... Injectables offer the advantage of not requiring ... insertion, and the combined oral contraceptive pills.

  3. Injection safety for immunisation--Andhra Pradesh experience.

    Science.gov (United States)

    Kaipilyawar, Satish B; Rao, R Gopal Krishna

    2005-04-01

    Injection safety is one component of a major immunisation project being implemented in partnership with Government of Andhra Pradesh and PATH, an international NGO. Prior to the project wrong and dangerous injection giving practices were present among the staff which needed immediate attention. It was decided to introduce auto disable syringes along with safety boxes with high quality training to staff and make all these available to all districts along with hepatitis B introduction in the routine immunisation. The State of Andhra Pradesh became the first to implement 'bundling' concept in the immunisation project. Implementation was planned to be done in a phased manner to cover all the 23 districts over a five-year period. For routine immunisation sessions, smaller locally produced boxes may be more acceptable. The Government of India made a decision on 21st July, 2004 on implementing injection safety. Injection safety and proper disposal of used needles and syringes can be successfully advocated if medical associations, paediatric associations, key governmental bodies and international agencies come together. PATH established a group and holds the secretariat for the India injection safety coalition on similar basis as the Safe Injection Global Network of WHO (SIGN). Description of AP system for safe disposal of needles and syringes using manual needle-cutters and plastics recycling has been depicted in this article.

  4. [ECCE with self-sealing cataract incision. Technique and clinical results].

    Science.gov (United States)

    Pham, D T; Wollensak, J; Drosch, S

    1995-06-01

    We present of modified technique for sutureless ECCE with a trapezoidal tunnel incision of 11 mm. The operation can be performed in a closed system because of the self-sealing wound construction. Compared to the sutured corneoscleral ECCE the new procedure has important advantages: the procedure is safe even during the critical phase following nucleus extraction. The procedure is therefore safer, faster, more economical and suture-induced astigmatism is avoided. Clinical experience after 2 years showed that postoperative complications were reduced significantly. Iris prolapse, wound dehiscens and hyphema occurred at a rate of 2%. The astigmatism (Jaffe analysis) was at a rate of 2 D, stable within 4 weeks after surgery, and did not change up to 2 years postoperatively. The astigmatism induced was then reduced about 0.5 D by a radical suture.

  5. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders;

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  6. Manual ECCE, the present state of the art.

    Science.gov (United States)

    Blumenthal, M

    1994-11-01

    Manual ECCE has proved to be safe surgery compatible with small incision, no stitches, possible topical anesthesia, very cost effective and quick rehabilitation. The technique has a learning curve and needs experience. "Mini-nuc" stands for mini nucleus. This surgery can be achieved only if performed under positive intraocular pressure (IOP). A BSS bottle is connected to the eye by an anterior chamber maintainer (ACM). The height of the BSS bottle controls the IOP during the surgery. Controlled IOP is a principle suggested for all kinds of cataract surgery. It creates continuous flow which washes out of the eye cortex debris, blood, pigment, etc. The BSS contains antibiotics and adrenalin, it creates low turbulence due to the small amount of BSS used per case, 30-50 cc. A round capsulorhexis is essential. A special way of hydrodissection creates a very small hard core nucleus delivered to the anterior chamber and is extracted out through a sclero-corneal tunnel using a glide introduced under the nucleus to guide the nucleus out. Positive IOP during all stages of surgery creates the best operative conditions for controlled surgery throughout all manipulations. This technique is a very cost effective system and at the same time provides a high quality procedure.

  7. Application of Engineered Cementitious Composites (ECC) in modular floor panels

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2008-01-01

    This paper describes the design, manufacturing, and structural behavior of a prefabricated floor panel consisting of a modular assembly of a thin-walled ECC slab and steel truss girders. The features of this composite structure include light weight, the modular manufacturing process...... with adaptability to various loading requirements, and the efficient utilization of material resources and industrial byproducts. The work described in this paper is a continuation of previous activities on composite floor panels in which light gage steel joists were integrally cast with the ECC slab. The modular...... concept introduced in this paper aims at improvements in the manufacturing process of the panels by casting the ECC slab separately and subsequently joining it with the steel trusses. The focus of this paper is on design and manufacturing of a prototype modular panel and on its structural behavior under...

  8. Visual outcomes after anterior vitrectomy: comparison of ECCE and phacoemulsification.

    Science.gov (United States)

    Bobrow, J C

    1999-01-01

    To determine whether vitrectomy instrumentation improved outcomes when vitreous loss occurred during either extracapsular cataract extraction (ECCE) or phacoemulsification (PE) with posterior chamber lens implantation (PCIOL). A consecutive series of ECCE + PCIOL (group 1: 1985-1989) and PE + PCIOL (group 2: 1993-1997) surgeries by a single surgeon was reviewed retrospectively. In group 1, 14 of 647 patients (2.2%) and in group 2, 9 of 665 patients (1.4%) experienced vitreous loss. In group 1, final visual acuity averaged 20/83; in group 2, 20/25 (P = .005). Average follow-up was 5.7 years (group 1) and 3.2 years (group 2). Uveitis, glaucoma, corneal problems, and retinal problems were assessed. Anterior vitrectomy reduced complications from vitreous loss. Fewer vitreous losses occurred with PE than ECCE. Patients with vitreous loss after PE attained better vision.

  9. Intraocular pressure following ECCE, phacoemulsification, and PC-IOL implantation.

    Science.gov (United States)

    Kooner, K S; Cooksey, J C; Perry, P; Zimmerman, T J

    1988-09-01

    Abnormal intraocular pressure (IOP), either transient or permanent, may follow extracapsular cataract extraction (ECCE) with phacoemulsification (PE) and posterior chamber intraocular lens (PC-IOL) implantation. We retrospectively studied IOP measurements at different intervals post ECCE and PE in 242 eyes of 211 patients: 105 males, 106 females, 198 Caucasians and 13 blacks. Elevated IOP (greater than 23 mm Hg) was observed in 20 eyes (8.2%). Only two patients (0.8%) had persistent (greater than 3 months) IOP elevation and needed antiglaucoma therapy. Six more eyes (2.5%), however, developed glaucoma after 1 year. Hence, the incidence of secondary pseudophakic glaucoma at the conclusion of this study was 3.3%. No patient required laser or other mechanical surgery for IOP control. ECCE and PE with PC-IOL does not appear to adversely affect IOP. Patients, however, must be followed closely, as some may develop glaucoma months after surgery.

  10. Environmental assessment: tar sand in situ steam injection experiment

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    A field experiment is planned for the in situ recovery of bitumen from tar sand. The site is located on a ten acre site 6.5 miles West of Vernal, Utah, and the experiment will last about six months. The experiment will utilize steam to lower the viscosity of the bitumen and drive it into production wells where it is recovered. Due to the small scale of this experiment, the impact of the proposed action will be minimal. Impact on local biological life will be minimal. The experiment will have no effect on aquatic habitats. No rare or endangered biological species will be affected by the experiment.

  11. Modeling of ECC materials using numerical formulations based on plasticity

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    This paper discusses the considerations for the establishment of a damage model for ECC. Three different length scales are used in the approach for deriving the damage model. On each length scale important phenomena are investigated by use of numerical and analytical calculations. On the micro...... scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  12. Ecce homo, a fisio-psicologia de um tipo

    OpenAIRE

    2007-01-01

    No presente estudo, pretendemos realizar uma leitura de Ecce homo balizada pelo procedimento genealógico, pela fisio-psicologia e pela tipologia presentes no pensamento de Nietzsche. Acreditamos que a mudança que se opera no tratamento do humano a partir dessas três noções permite a Nietzsche, em Ecce homo, realizar uma espécie de duplo movimento. Por um lado, o filósofo realiza a máxima afirmação da vida e de si mesmo, dando expressão a uma série de estados afetivos que o constitui. Por outr...

  13. Un Ecce Homo de Antonio del Castillo en Granada

    Directory of Open Access Journals (Sweden)

    Montes González, Francisco

    2012-03-01

    Full Text Available The author presents a previously unknown painting by the Baroque artist from Cordoba, Antonio del Castillo y Saavedra. It is an Ecce Homo, a late work, and located in a private collection in Granada.Este artículo presenta el último aporte en el catálogo del pintor barroco cordobés Antonio del Castillo y Saavedra. Se trata de un lienzo con la iconografía del Ecce Homo, perteneciente a su última etapa artística, localizado en una colección particular de Granada.

  14. Experimental and theoretical study for the multidimensional phenomena of the ECC bypass in the DVI system downcomer during reflood phase of the LBLOCA

    Energy Technology Data Exchange (ETDEWEB)

    Song, Chul Hwa; Cho, Hyoung Kyu; Yun, Byong Jo; Euh, Dong Jin; Kwon, Tae Soon

    2005-02-01

    In the present study, a new scaling methodology, 'Modified Linear Scaling', was developed which can reproduce the multidimensional ECC behaviors in the DVI system downcomer and its applicability was experimentally and analytically evaluated. An exploratory test was performed to identify the mechanism and flow patterns of the ECC bypass and to investigate the effect of the downcomer geometry on the ECC bypass. Based on the observation results, an analysis for the two-dimensional film flow was conducted, which was found to the dominant flow regime in the DVI system downcomer and it introduced the Wallis parameters as the major scaling parameters of the direct ECC bypass. From the experiments and analysis, scaling requirements of the multidimensional phenomena were derived that the aspect ratio of the test facility and the film spreading width of the ECC should be preserved in the proto and reduced model. The modified linear scaling was developed which can satisfy the scaling requirements from the two-dimensional two-fluid equations and some important phenomena, which may not be fully represented by the equations, were additionally analyzed as a local phenomena scaling. The applicability of the scaling methodology is experimentally and analytically evaluated from the separate effect tests for the direct ECC bypass and sweep-out in various scales of the test sections and the developed analytical models.

  15. Computational Analysis of Safety Injection Tank Performance

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Nietiadia, Yohanes Setiawan; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Addad, Yacine; Yoon, Ho Joon [Khalifa University of Science Technology and Research, Abu Dhabi (United Arab Emirates)

    2015-10-15

    The APR 1400 is a large pressurized water reactor (PWR). Just like many other water reactors, it has an emergency core cooling system (ECCS). One of the most important components in the ECCS is the safety injection tank (SIT). Inside the SIT, a fluidic device is installed, which passively controls the mass flow of the safety injection and eliminates the need for low pressure safety injection pumps. As more passive safety mechanisms are being pursued, it has become more important to understand flow structure and the loss mechanism within the fluidic device. Current computational fluid dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study proposes to find a more exact result using CFD and more realistic modeling. The SIT of APR1400 was analyzed using MARS and CFD. CFD calculation was executed first to obtain the form loss factor. Using the two form loss factors from the vendor and calculation, calculation using MARS was performed to compare with experiment. The accumulator model in MARS was quite accurate in predicting the water level. The pipe model showed some difference with the experimental data in the water level.

  16. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  17. Early Childhood Caries (ECC): an infectious transmissible oral disease

    NARCIS (Netherlands)

    H.R. Poureslami; W.E. van Amerongen

    2009-01-01

    Dental caries in babies and toddlers is called Early Childhood Caries (ECC). It is an infectious and transmissible die-to-bacterial disease. Detailed knowledge regarding the acquisition and transmission of infectious agents facilitates a more comprehensive approach toward prevention. Mutans streptoc

  18. Early Childhood Caries (ECC): an infectious transmissible oral disease

    NARCIS (Netherlands)

    Poureslami, H.R.; van Amerongen, W.E.

    2009-01-01

    Dental caries in babies and toddlers is called Early Childhood Caries (ECC). It is an infectious and transmissible die-to-bacterial disease. Detailed knowledge regarding the acquisition and transmission of infectious agents facilitates a more comprehensive approach toward prevention. Mutans

  19. Early Childhood Caries (ECC): an infectious transmissible oral disease

    NARCIS (Netherlands)

    Poureslami, H.R.; van Amerongen, W.E.

    2009-01-01

    Dental caries in babies and toddlers is called Early Childhood Caries (ECC). It is an infectious and transmissible die-to-bacterial disease. Detailed knowledge regarding the acquisition and transmission of infectious agents facilitates a more comprehensive approach toward prevention. Mutans streptoc

  20. Modeling of ECC materials using numerical formulations based on plasticity

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    This paper discusses the considerations for the establishment of a damage model for ECC. Three different length scales are used in the approach for deriving the damage model. On each length scale important phenomena are investigated by use of numerical and analytical calculations. On the micro sc...

  1. Deportation experiences of women who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Robertson, Angela M; Lozada, Remedios; Vera, Alicia; Palinkas, Lawrence A; Burgos, José Luis; Magis-Rodriguez, Carlos; Rangel, Gudelia; Ojeda, Victoria D

    2012-04-01

    Deportation from the United States for drug offenses is common, yet the consequences of deportation for women drug users are poorly documented. In 2008, in Tijuana, Mexico, we conducted an exploratory qualitative study of migration, deportation, and drug abuse by interviewing 12 Mexican injection-drug-using women reporting U.S. deportation. Women reported heavy drug use before and after deportation, but greater financial instability and physical danger following deportation than when in the United States. We identified an unmet need for health and social services among deported drug-using women, including HIV prevention, drug treatment, physical and mental health services, and vocational training. Binational coordination is needed to help deported women resettle in Mexico.

  2. Deportation Experiences of Women Who Inject Drugs in Tijuana, Mexico

    Science.gov (United States)

    Robertson, Angela M.; Lozada, Remedios; Vera, Alicia; Palinkas, Lawrence A.; Burgos, José Luis; Magis-Rodriguez, Carlos; Rangel, Gudelia; Ojeda, Victoria D.

    2013-01-01

    Deportation from the United States for drug offenses is common, yet the consequences of deportation for women drug users are poorly documented. In 2008, in Tijuana, Mexico, we conducted an exploratory qualitative study of migration, deportation, and drug abuse by interviewing 12 Mexican injection-drug-using women reporting U.S. deportation. Women reported heavy drug use before and after deportation, but greater financial instability and physical danger following deportation than when in the United States. We identified an unmet need for health and social services among deported drug-using women, including HIV prevention, drug treatment, physical and mental health services, and vocational training. Binational coordination is needed to help deported women resettle in Mexico. PMID:21917563

  3. Current drive experiments in the Helicity Injected Torus - II

    Science.gov (United States)

    Hamp, W. T.; Redd, A. J.; Jarboe, T. R.; Nelson, B. A.; O'Neill, R. G.; Raman, R.; Sieck, P. E.; Smith, R. J.; Mueller, D.

    2006-10-01

    The HIT-II spherical torus (ST) device has demonstrated four toroidal plasma current drive configurations to form and sustain a tokamak: 1) inductive (ohmic) current drive, 2) coaxial helicity injection (CHI) current drive, 3) CHI initiated plasmas with ohmic sustainment (CHI+OH), and 4) ohmically initiated plasmas with CHI edge current drive (OH+ECD). CHI discharges with a sufficiently high ratio of injector current to toroidal field current form a closed flux core, and amplify the injector poloidal flux through magnetic reconnection. CHI+OH plasmas are more robust than unassisted ohmic discharges, with a wider operating space and more efficient use of the transformer Volt-seconds. Finally, edge CHI can enhance the plasma current of an ohmic discharge without significantly degrading the quality of the discharge. Results will be presented for each HIT-II operating regime, including empirical performance scalings, applicable parametric operating spaces, and requirements to produce these discharges. Thomson scattering measurements and EFIT simulations are used to evaluate confinement in several representative plasmas. Finally, we outline extensions to the HIT-II CHI studies that could be performed with NSTX, SUNIST, or other ST devices.

  4. Visualizing aerosol-particle injection for diffractive-imaging experiments

    CERN Document Server

    Awel, Salah; Eckerskorn, Niko; Wiedorn, Max; Horke, Daniel A; Rode, Andrei V; Küpper, Jochen; Chapman, Henry N

    2015-01-01

    Delivering sub-micrometer particles to an intense x-ray focus is a crucial aspect of single-particle diffractive-imaging experiments at x-ray free-electron lasers. Enabling direct visualization of sub-micrometer aerosol particle streams without interfering with the operation of the particle injector can greatly improve the overall efficiency of single-particle imaging experiments by reducing the amount of time and sample consumed during measurements. We have developed in-situ non-destructive imaging diagnostics to aid real-time particle injector optimization and x-ray/particle-beam alignment, based on laser illumination schemes and fast imaging detectors. Our diagnostics are constructed to provide a non-invasive rapid feedback on injector performance during measurements, and have been demonstrated during diffraction measurements at the FLASH free-electron laser.

  5. VLF wave injection experiments from Siple Station, Antarctica

    OpenAIRE

    R.A., Helliwell

    1987-01-01

    The background of VLF wave-particle experiments from Siple Station, Antarctica, including wave-induced precipitation is briefly reviewed. Single frequency ducted signals that exceed a certain 'threshold' intensity are observed at the conjugate point (Roberval, Quebec) to be amplified 30-50dB, with temporal growth rates of 30-200dB/s. Following saturation, variable frequency emissions are triggered. When a second signal is added to the first, with a frequency spacing Df

  6. Injecting learning experience into geoethics for human and natural sustainability

    Science.gov (United States)

    Crookall, David

    2016-04-01

    Our early life experience has a strong influence on our actions in later life. Humans today are just starting to re-learn, collectively, how to treat Earth with the respect that it deserves and that is needed for our offspring to inherit a decent home. However, we still have a long way to go to instill in people at large the ethics, knowledge and skills necessary to ensure a healthy journey for humanity on spaceship. The experience of early upbringing, of schooling and of everyday life is probably the only path strong enough to develop in people a strong desire for ethical behaviour towards their environment. The problem is that the measures taken today to ensure the development of ethical behaviours in the population at large are woefully inadequate. At best, western school programmes contain a few lessons devoted to the environment, and even then they usually just pay lip service to the basics of the environment; they rarely aim to instill skills and knowledge in order to understand and care deeply for the environment. My presentation will suggest some practical ways to help communities build ethical frameworks and strategies to guide and generate tools, methods and activities that guide young people (pupils, students, scholars, researchers) to toward more ethical behaviours regarding their environment and their communities. Examples might include: - Developing geoethical dimensions of internships, in all areas; - Designing, testing and running simulation/games+debriefing providing a rich affective-cognitive context for grappling with geoethical problems- eg, FISH BANKS, KEEP COOL. - Pressuring governments to make geoethics, environmental care and climate change understanding central components of (almost) all educational programmes (in, eg, history, language, business, law, medicine, etc). - Subsidizing environmental-care summer schools for families and teachers at all levels. - Etc. One of my actions is founding a academic journal in the area, maybe with the

  7. Three-dimensional modelling of an injection experiment in the anaerobic part of a landfill plume

    DEFF Research Database (Denmark)

    Juul Petersen, Michael; Engesgaard, Peter Knudegaard; Bjerg, Poul Løgstrup

    1998-01-01

    Analytical and numerical three-dimensional (3-D) simulations have been conducted and compared to data obtained from a large-scale (50 m), natural gradient field injection experiment. Eighteen different xenobiotic compounds (i.e. benzene, toluene, o-xylene, naphthalene, 1,1,1-TCA, PCE, and TCE......) and bromide as a conservative tracer, were for 195 days injected in the anaerobic part of the leachate plume downgradient of the Grindsted Landfill, Denmark. The injection area is an unconfined sandy aquifer with heterogeneities of clay and silt layers. Simulations with homogeneous and heterogeneous hydraulic...

  8. An enhancement of plasma density by neutral gas injection observed in SEPAC Spacelab-1 experiment

    Science.gov (United States)

    Sasaki, S.; Kawashima, N.; Kuriki, K.; Yanagisawa, M.; Obayashi, T.; Kubota, S.; Roberts, W. T.; Reasoner, D. L.; Taylor, W. W. L.; Williamson, P. R.

    1985-01-01

    An enhancement of plasma density observed during a neutral gas injection in Space Experiments with Particle Accelerators by the Space Shuttle/Spacelab-1 is presented. When a plume of nitrogen gas was injected from the orbiter into space, a large amount of plasma was detected by an onboard plasma probe. The observed density often increased beyond the background plasma density and was strongly dependent on the attitude of the orbiter with respect to the velocity vector. This effect has been explained by a collisional interaction between the injected gas molecules and the ionospheric ions relatively drifting at the orbital speed.

  9. The microstructure of self-healed PVA ECC under wet and dry cycles

    Directory of Open Access Journals (Sweden)

    Jia Huan Yu

    2010-06-01

    Full Text Available Self-healing of ECC (Engineered Cementitious Composites subjected to cyclic wetting and drying regimes is investigated in this paper. ECC structures subjected to outdoor environmental conditions such as wind and rain runoff can be simulated by accelerated test method of wetting and drying cycles. Uniaxial tensile tests of ECC M45 and ECC 2.8FA specimen are conducted respectively. It is found that crack width of ECC 2.8FA is around 10 μm with increased amount of fly ash, while the crack width of ECC M45 is around 100 μm. New insights about the microstructure and chemical composition analysis of ECC specimens initially cracked to 2% strain and then self-healed under wet-dry cycles are presented.

  10. An overview of the BWR ECCS strainer blockage issues

    Energy Technology Data Exchange (ETDEWEB)

    Serkiz, A.W.; Marshall, M.L. Jr.; Elliott, R. [Nuclear Regulatory Commission, Washington, DC (United States)

    1996-03-01

    This Paper provides a brief overview of actions taken in the mid 1980s to resolve Unresolved Safety Issue (USI) A-43, {open_quotes}Containment Emergency Sump Performance,{close_quotes} and their relationship to the BWR strainer blockage issue; the importance of insights gained from the Barseback-2 (a Swedish BWR) incident in 1992 and from ECCS strainer testing and inspections at the Perry nuclear power plant in 1992 and 1993; an analysis of an US BWR/4 with a Mark I containment; an international community sharing of knowledge relevant to ECCS strainer blockage, additional experimental programs; and identification of actions needed to resolve the strainer blockage issue and the status of such efforts.

  11. HIGH SPEED POINT ARITHMETIC ARCHITECTURE FOR ECC ON FPGA

    Directory of Open Access Journals (Sweden)

    Rahila Bilal,

    2010-09-01

    Full Text Available Elliptic curve cryptography plays a crucial role in networking and communication security. ECC have evolved in the recent past as an important alternative to established systems like RSA. This paper describes the implementation of an elliptic curve coprocessor based on the FPGA , which can provide a significant speedup for these cryptosystems. The FPGA configuration file is synthesized from VHDL code applying different hardware synthesis products. The implementation of ECC lies in three levels: scalar multiplication, point addition/doubling and finite field modular arithmetic. In this paper, we present a novel fast architecture for the point addition/doubling level in the projective coordinate. The proposed Architecture is based on Binary Field. The Design performs multiplication using Polynomial Basis. Analysis shows that, with reasonable hardware overhead, our architecture can achieve a high speedup for the point addition operation and point Doubling operation.Furthermore, the architecture is parameterized for different data widths to evaluate the optimal resource utilization.

  12. Experimental Study on the Compressive Behavior of CFRP/ECCs

    Institute of Scientific and Technical Information of China (English)

    SUN Wen-bin

    2010-01-01

    In this study, nine square concrete columns, including six CFRP/ECCs and three plain concrete control specimen columns, were prepared. The CFRP tubes with fibers oriented in the hoop direction were manufactured with 10, 20, or 40 mm rounded corner radii at vertical edges. A 100 mm overlap in the direction of fibers was provided to ensure a proper bond. Uniaxial compression tests were conducted to investigate the compressive behaviors including the axial strength, stress-strain response, and ductility. It is evident that the CFRP tube confinement can improve the compressive behavior of concrete core, in terms of axial compressive strength or axial deformability. Based on the experimental results and some existing test database attained by other researchers, a design-oriented model is developed. The predictions of the model for CFRP/ECCs show good agreement with test results.

  13. Fate of herbicides in a shallow aerobic aquifer: A continuous field injection experiment (Vejen,Denmark)

    DEFF Research Database (Denmark)

    Broholm, Mette; Rügge, K.; Tuxen, Nina

    2001-01-01

    A continuous, natural gradient, field injection experiment, involving six herbicides and a tracer, was performed in a shallow aerobic aquifer near Vejen, Denmark. Bentazone, ()-2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP), dichlorprop, isoproturon, and the dichlobenil metabolite 2,6-dichlor......, with selected individual points for a longer period. The bromide plume followed a complex path through the monitoring network downgradient of the injection wells. The plume movement was controlled by spatially varied hydraulic conductivities of the sand deposit and influenced by asynchronous seasonal variation...... in groundwater potentials. An average flow velocity of 0.5 m/d was observed, as depicted by bromide. Bentazone, BAM, MCPP, and dichlorprop retardation was negligible, and only slight retardation of isoproturon was observed in the continuous injection experiment and a preceding pulse experiment. No degradation...

  14. Three-dimensional spiral injection scheme for the g-2/EDM experiment at J-PARC

    Science.gov (United States)

    Iinuma, Hiromi; Nakayama, Hisayoshi; Oide, Katsunobu; Sasaki, Ken-ichi; Saito, Naohito; Mibe, Tsutomu; Abe, Mitsushi

    2016-10-01

    A newly developed three-dimensional spiral injection scheme for beam insertion into a solenoidal storage ring is reported. A new planned muon g-2/EDM experiment at J-PARC aims to measure g - 2 to a factor of 5 better statistical precision and a factor of 100 better sensitivity for the electric dipole moment (EDM) measurement compared to previous experiments. The J-PARC experiment will use a 3-T MRI solenoid magnet as the muon storage ring with a 0.66 m diameter to achieve a 1-ppm level of local uniformity. The previous g - 2 injection scheme is not applicable for beam injection into a small ring. The new scheme provides a smooth injection utilizing a radial solenoidal fringe field, without causing an error field in the storage volume. The expected storage efficiency is 80% and over, which is to be compared to 3.5% for the previous g - 2 experiment. In addition, the ability to control the storage plane is important for the EDM measurement. In this paper, we introduce the conceptual design and required beam parameters in terms of Twiss functions and the expected injection efficiency.

  15. Designing Fault-Injection Experiments for the Reliability of Embedded Systems

    Science.gov (United States)

    White, Allan L.

    2012-01-01

    This paper considers the long-standing problem of conducting fault-injections experiments to establish the ultra-reliability of embedded systems. There have been extensive efforts in fault injection, and this paper offers a partial summary of the efforts, but these previous efforts have focused on realism and efficiency. Fault injections have been used to examine diagnostics and to test algorithms, but the literature does not contain any framework that says how to conduct fault-injection experiments to establish ultra-reliability. A solution to this problem integrates field-data, arguments-from-design, and fault-injection into a seamless whole. The solution in this paper is to derive a model reduction theorem for a class of semi-Markov models suitable for describing ultra-reliable embedded systems. The derivation shows that a tight upper bound on the probability of system failure can be obtained using only the means of system-recovery times, thus reducing the experimental effort to estimating a reasonable number of easily-observed parameters. The paper includes an example of a system subject to both permanent and transient faults. There is a discussion of integrating fault-injection with field-data and arguments-from-design.

  16. Treatment of rectal prolapse in children with cow milk injection sclerotherapy: 30-year experience

    Science.gov (United States)

    Zganjer, Mirko; Cizmic, Ante; Cigit, Irenej; Zupancic, Bozidar; Bumci, Igor; Popovic, Ljiljana; Kljenak, Antun

    2008-01-01

    AIM: To evaluate the role and our experience of injection sclerotherapy with cow milk in the treatment of rectal prolapse in children. METHODS: In the last 30 years (1976-2006) we made 100 injections of sclerotherapy with cow milk in 86 children. In this study we included children who failed to respond to conservative treatment and we perform operative treatment. RESULTS: In our study we included 86 children and in all of the patients we perform cow milk injection sclerotherapy. In 95.3% (82 children) of patients sclerotherapy was successful. In 4 (4.7%) patients we had recurrent rectal prolapse where we performed operative treatment. Below 4 years we had 62 children (72%) and 24 older children (28%). In children who needed operative treatment we performed Thiersch operation and without any complications. CONCLUSION: Injection sclerotherapy with cow milk for treatment rectal prolapse in children is a simple and effective treatment for rectal prolapse with minimal complications. PMID:18205264

  17. Registration of ELF waves in rocket-satellite experiment with plasma injection

    Science.gov (United States)

    Korobeinikov, V. G.; Oraevskii, V. N.; Ruzhin, Iu. Ia.; Sobolev, Ia. P.; Skomarovskii, V. S.; Chmyrev, V. M.; Namazov, C. A.; Pokhunkov, A. A.; Nesmeianov, V. I.

    1992-12-01

    Two rocket KOMBI-SAMA experiments with plasma injection at height 100-240 km were performed in August 1987 in the region of Brazilian magnetic anomaly (L = 1.25). The launching time of the rocket was determined so that plasma injection was at the time when COSMOS 1809 satellite passed as close as possible to magnetic tube of injection. Caesium plasma jet was produced during not less than 300 s by an electric plasma generator separated from the payload. When the satellite passed the geomagnetic tube intersecting the injection region an enhancement of ELF emission at 140 Hz, 450 Hz by a factor of 2 was registered on board the satellite. An enhancement of energetic particle flux by a factor of 4-5 was registered on board the rocket. Observed ELF emission below 100 Hz is interpreted as the generation of oblique electromagnetic ion-cyclotron waves due to drift plasma instability at the front of the plasma jet.

  18. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S., E-mail: yhwang@snu.ac.kr

    2015-10-15

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  19. Self-Healing of Microcracks in Engineered Cementitious Composites (ECC) Under a Natural Environment

    OpenAIRE

    Li, Victor C.; Emily N. Herbert

    2013-01-01

    This paper builds on previous self-healing engineered cementitious composites (ECC) research by allowing ECC to heal outdoors, in the natural environment, under random and sometimes extreme environmental conditions. Development of an ECC material that can heal itself in the natural environment could lower infrastructure maintenance costs and allow for more sustainable development in the future by increasing service life and decreasing the amount of resources and energy needed for repairs. Det...

  20. Feeding pattern a dual risk? otitis media (OM and early childhood caries (ECC

    Directory of Open Access Journals (Sweden)

    P. Sangeetha

    2014-04-01

    Full Text Available Purpose: To determine the prevalence of Otitis media (OM and Early childhood caries (ECC and their coexistence in children with a history of faulty feeding patterns. Method: Children aged 5 years and below were recruited at random from dental and medical hospitals. Parents of these children were posed with questions about the feeding methods, feeding patterns such as duration, frequency, position, burping, specific childhood illness etc. Children (120 were examined for ECC by a Paedodontist and OM by an Otolaryngologist and were segregated into three groups i.e. Control group, ECC group and OM group respectively. The ECC group was sub grouped into ECC only and ECC&OM group. The OM group was also similarly sub grouped into OM group and OM&ECC group. Collected data were tabulated and subjected for statistical analysis using Pearson Chi – square test. Results: Prevalence of ECC, OM, and their coexistence increased with age P < 0.001, whereas gender difference was not statistically significant. Overall Prevalence of their coexistence in children was 51.25%. Significant percentages (25% of children in the OM group were fed in supine position. Children fed on demand (47.5% experienced ECC. overall 85% (p=.017 of children had coexistence of ECC&OM fed on demand and during bed time. Significant numbers of children who were burped occasionally after feeding (35% or were not burped at all (12.5% were affected with both ECC and OM. Conclusion: Prevalence of their coexistence was higher in children with OM. Significant association existed between on demand feeding and ECC; supine feeding position and OM. Risk factors in common for both the disease were combined feeding position, on demand, bed time feeding and occasionally burping.

  1. Simulation experiments to generate broadband chaos using dual-wavelength optically injected Fabry-Perot laser

    Science.gov (United States)

    Obaid, Hafiz Muhammad; Khawar Islam, Muhammad; Obaid Ullah, Muhammad

    2016-08-01

    Broadband chaos can be generated by beating two wavelengths in a hybrid arrangement of Fabry-Perot (FP) Laser and Fiber ring cavity by injecting dual wavelengths. The bandwidth of generated chaos can be controlled by detuning different modes of FP Laser for beating. The bandwidth of generated chaos increased to many folds depending upon the injected strength and wavelength spacing matched to FP laser modes. The bandwidth enhancement in different simulation experiments conducted is optimized by varying different parameters of FP laser and cavity. The waveforms are analyzed and Lyapunov exponents are calculated in order to validate the existence of high bandwidth non-pulsating chaos.

  2. Early results of microwave transmission experiments through an overly dense rectangular plasma sheet with microparticle injection

    Science.gov (United States)

    Gillman, Eric D.; Amatucci, W. E.

    2014-06-01

    These experiments utilize a linear hollow cathode to create a dense, rectangular plasma sheet to simulate the plasma layer surrounding vehicles traveling at hypersonic velocities within the Earth's atmosphere. Injection of fine dielectric microparticles significantly reduces the electron density and therefore lowers the electron plasma frequency by binding a significant portion of the bulk free electrons to the relatively massive microparticles. Measurements show that microwave transmission through this previously overly dense, impenetrable plasma layer increases with the injection of alumina microparticles approximately 60 μm in diameter. This method of electron depletion is a potential means of mitigating the radio communications blackout experienced by hypersonic vehicles.

  3. Implementation and verification of different ECC mitigation designs for BRAMs in flash-based FPGAs

    CERN Document Server

    Yang, Zhenlei; Zhang, Zhangang; Liu, Jie; Su, Hong

    2015-01-01

    Embedded RAM blocks (BRAMs) in field programmable gate arrays (FPGAs) are susceptible to single event effects (SEEs) induced by environmental factors such as cosmic rays, heavy ions, alpha particles and so on. As technology scales, the issue will be more serious. In order to tackle this issue, two different error correcting codes (ECCs), the shortened Hamming codes and shortened BCH codes, are investigated in this paper. The concrete design methods of the codes are presented. Also, the codes are both implemented in flash-based FPGAs. Finally, the synthesis report and simulation results are presented in the paper. Moreover, the heavy-ion experiments are performed, the experimental results indicate that the error cross-section using the shortened Hamming codes can be reduced by two orders of magnitude compared with the device without mitigation, and no errors are discovered in the experiments for the device using the shortened BCH codes.

  4. Analysis of Cavity Pressure and Warpage of Polyoxymethylene Thin Walled Injection Molded Parts: Experiments and Simulations

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2014-01-01

    , melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number......Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage...... was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure...

  5. Disease Management of Early Childhood Caries: ECC Collaborative Project.

    Science.gov (United States)

    Ng, Man Wai; Ramos-Gomez, Francisco; Lieberman, Martin; Lee, Jessica Y; Scoville, Richard; Hannon, Cindy; Maramaldi, Peter

    2014-01-01

    Until recently, the standard of care for early childhood caries (ECC) has been primarily surgical and restorative treatment with little emphasis on preventing and managing the disease itself. It is now recognized that surgical treatment alone does not address the underlying etiology of the disease. Despite costly surgeries and reparative treatment, the onset and progression of caries are likely to continue. A successful rebalance of risk and protective factors may prevent, slow down, or even arrest dental caries and its progression. An 18-month risk-based chronic disease management (DM) approach to address ECC in preschool children was implemented as a quality improvement (QI) collaborative by seven teams of oral health care providers across the United States. In the aggregate, fewer DM children experienced new cavitation, pain, and referrals to the operating room (OR) for restorative treatment compared to baseline historical controls. The teams found that QI methods facilitated adoption of the DM approach and resulted in improved care to patients and better outcomes overall. Despite these successes, the wide scale adoption and spread of the DM approach may be limited unless health policy and payment reforms are enacted to compensate providers for implementing DM protocols in their practice.

  6. Development of CANDU ECCS performance evaluation methodology and guides

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Kwang Hyun; Park, Kyung Soo; Chu, Won Ho [Korea Maritime Univ., Jinhae (Korea, Republic of)

    2003-03-15

    The objectives of the present work are to carry out technical evaluation and review of CANDU safety analysis methods in order to assist development of performance evaluation methods and review guides for CANDU ECCS. The applicability of PWR ECCS analysis models are examined and it suggests that unique data or models for CANDU are required for the following phenomena: break characteristics and flow, frictional pressure drop, post-CHF heat transfer correlations, core flow distribution during blowdown, containment pressure, and reflux rate. For safety analysis of CANDU, conservative analysis or best estimate analysis can be used. The main advantage of BE analysis is a more realistic prediction of margins to acceptance criteria. The expectation is that margins demonstrated with BE methods would be larger that when a conservative approach is applied. Some outstanding safety analysis issues can be resolved by demonstration that accident consequences are more benign than previously predicted. Success criteria for analysis and review of Large LOCA can be developed by top-down approach. The highest-level success criteria can be extracted from C-6 and from them, the lower level criteria can be developed step-by-step, in a logical fashion. The overall objectives for analysis and review are to verify radiological consequences and frequency are met.

  7. Disease Management of Early Childhood Caries: ECC Collaborative Project

    Directory of Open Access Journals (Sweden)

    Man Wai Ng

    2014-01-01

    Full Text Available Until recently, the standard of care for early childhood caries (ECC has been primarily surgical and restorative treatment with little emphasis on preventing and managing the disease itself. It is now recognized that surgical treatment alone does not address the underlying etiology of the disease. Despite costly surgeries and reparative treatment, the onset and progression of caries are likely to continue. A successful rebalance of risk and protective factors may prevent, slow down, or even arrest dental caries and its progression. An 18-month risk-based chronic disease management (DM approach to address ECC in preschool children was implemented as a quality improvement (QI collaborative by seven teams of oral health care providers across the United States. In the aggregate, fewer DM children experienced new cavitation, pain, and referrals to the operating room (OR for restorative treatment compared to baseline historical controls. The teams found that QI methods facilitated adoption of the DM approach and resulted in improved care to patients and better outcomes overall. Despite these successes, the wide scale adoption and spread of the DM approach may be limited unless health policy and payment reforms are enacted to compensate providers for implementing DM protocols in their practice.

  8. Experiments and numerical analysis of a control method for natural circulation through helium gas injection

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tetsuaki, E-mail: ttakeda@yamanashi.ac.jp; Hatori, Hirofumi; Funatani, Shumpei

    2016-09-15

    This study investigated a control method for natural circulation of air by helium gas injection. A depressurization accident is a design-basis accident of a very high temperature reactor. When a primary pipe rupture accident occurs, air is expected to enter the reactor pressure vessel from the breach. Thus, in-core graphite structures are oxidized. In order to predict and analyze the phenomena of air ingress during a depressurization accident, numerical analysis was carried out using a one-dimensional (1D) analysis code and three-dimensional computational fluid dynamics (3D CFD). An experiment was carried out regarding natural circulation using a circular pipe consisting of a reverse U-shaped channel. The channel consisted of two vertical heated and cooled pipes. The temperature difference between the vertical pipes was maintained at 40–80 K, and a small amount of helium gas was injected into the channel. The injected volume of helium was about 3.1–12.5% of the total channel volume. After injecting helium gas, each component gas moved through molecular diffusion and very weak natural circulation. After approximately 1180 s, ordinary natural circulation of air was suddenly produced. The numerical results of the 3D CFD code were in good agreement with the experimental results. The numerical results also showed that the natural circulation of air can be controlled by helium gas injection.

  9. An anaerobic field injection experiment in a landfill leachate plume (Grindsted, Denmark)

    DEFF Research Database (Denmark)

    Albrechtsen, Hans-Jørgen; Bjerg, Poul Løgstrup; Ludvigsen, L.

    1999-01-01

    Redox conditions may be environmental factors which affect the fate of the xenobiotic organic compounds. Therefore the redox conditions were characterized in an anaerobic, leachate-contaminated aquifer 15–60 m downgradient from the Grindsted Landfill, Denmark, where an field injection experiment...... to the sediment samples. Samples were investigated with respect to groundwater chemistry, including hydrogen and volatile fatty acids (VFAs) and sediment geochemistry, and bioassays were performed. The groundwater chemistry, including redox sensitive species for a large number of samples, varied over time during...... the experimental period of 924 days owing to variations in the leachate from the landfill. However, no indication of change in the redox environment resulting from the field injection experiment or natural variation was observed in the individual sampling points. The methane, Fe(II), hydrogen, and VFA groundwater...

  10. Part weight verification between simulation and experiment of plastic part in injection moulding process

    Science.gov (United States)

    Amran, M. A. M.; Idayu, N.; Faizal, K. M.; Sanusi, M.; Izamshah, R.; Shahir, M.

    2016-11-01

    In this study, the main objective is to determine the percentage difference of part weight between experimental and simulation work. The effect of process parameters on weight of plastic part is also investigated. The process parameters involved were mould temperature, melt temperature, injection time and cooling time. Autodesk Simulation Moldflow software was used to run the simulation of the plastic part. Taguchi method was selected as Design of Experiment to conduct the experiment. Then, the simulation result was validated with the experimental result. It was found that the minimum and maximum percentage of differential of part weight between simulation and experimental work are 0.35 % and 1.43 % respectively. In addition, the most significant parameter that affected part weight is the mould temperature, followed by melt temperature, injection time and cooling time.

  11. [Visco-hydraulic irrigation of the lens cortex. A safe ECCE method].

    Science.gov (United States)

    Friedburg, D

    1994-12-01

    The safe and effective Hydrojet nucleus expression (Klin Monatsbl Augenheilkd 1993; 202:288-291) should be completed by a safe non traumatic and easy to perform method of cortex removal. OPERATION TECHNIQUE: 8-mm tunnel incision, spiral capsulorhexis, hydrodissection and viscodissection of the nucleus, hydrojet nucleus expression. The lens cortex can be separated from the lens capsule by injection of hydroxypropylmethylcellulose (Metho), the viscoelastic substance acts as a wedge to separate the cortex from the capsule step by step. Finally the cortex is expressed by the injection of Metho. The capsule remains so clean, that often polishing is not necessary. PMMA lenses with an over all diameter of 10 or 11-mm and 7-mm optics were implanted. In 100 consecutive cases complications which occurred intraoperatively or within the following 2 days were listed. The following complications occurred: Hyphaema (2x, the blood disappeared spontaneously within 4-5 days), small cortex flake in the anterior chamber (2x), rhexis rim not intact (1x, nevertheless exact lens centration in the bag). No lesion of the capsule/zonule diaphragm, no fibrin reaction, no corneal edema. The method described is a safe method for ECCE. Capsulorhexis and tunnel incision are required. The method does not need any high technology equipment.

  12. BIOGRAPHY OR A DECLARATION OF PHILOSOPHICAL AMBITION: HOW TO READ ECCE HOMO BY NIETZSCHE

    Directory of Open Access Journals (Sweden)

    Lúcia Schneider Hardt

    2015-06-01

    Full Text Available This article discusses the book Ecce homo, by Nietzsche, defending that the text is an interpretation of the philosopher himself on her own thought, not to give the book a sacred tone, nor to stress his biography, but affirming a dissonant thought that indicates his philosophical ambition. With no constraints, Nietzsche presents his conflicts, passions, deceptions, announcing a tragic dimension of life that is not guided by pessimism, but by happiness of living intensely, understanding suffering as one of the facets of life. His philosophy derives from a life demand, transfigured by an experience that promotes self cultivation and the possibility of “becoming what one really is” through the “applying” of one’s own genealogic method.

  13. New Generation of ELF/VLF Wave Injection Experiments for HAARP

    Science.gov (United States)

    Sonwalkar, V. S.; Reddy, A.; Watkins, B. J.

    2016-12-01

    We present a ray tracing study to investigate the feasibility of a new generation of wave injection experiments from HAARP transmitter (L 4.9). Highly successful whistler mode wave injection experiments from SIPLE station, Antarctica, have established the importance of such experiments to study magnetospheric wave-particle interactions, and for cold and hot plasma diagnostics [Helliwell and Katsufrakis, 1974; Carpenter and Miller, 1976; Sonwalkar et al., 1997]. Modulated heating experiments from HAARP have shown that it is possible to launch ELF/VLF waves into the magnetosphere that can be observed on the ground after one-, two-, and multi-hop ducted propagation [Inan et al., 2004]. Recent research has also shown that ionospheric heating experiments using HAARP can lead to the formation of magnetospheric ducts [e.g. Milikh et al., 2010; Fallen et al., 2011]. Collectively, these results indicate that the HAARP (or similar) transmitter can be used first to form ducts on nearby L shells, and then to inject and trap transmitter generated ELF/VLF waves in those ducts. Ray tracing studies using a model magnetosphere shows that ELF/VLF waves in a few kilohertz range can be trapped in ducts with L shells near the HAARP transmitter. For example, 1.5 kHz waves injected from L shell = 4.9 and altitude = 200 km can be trapped in ducts located within 0.3 L of the transmitter L-shell. The duct parameters needed for ray-trapping are typically duct width dL 0.1-0.3 and duct enhancement factor dNe/Ne 10-20% or more. The location of plasmapause with respect to transmitter plays a role in the nature of trapping. The duct locations and parameters required for trapping ELF/VLF waves inside the ducts are consistent with past observations of ducts generated by the HAARP transmitter. Ray tracing calculations provide trapped wave normal angles, time delays, resonant energetic electron energy, estimates of wave intensity inside the duct, on the ground, and on satellites such DEMETER, Van

  14. Mechanical Behavior of Rectangular Steel-Reinforced ECC/Concrete Composite Column under Eccentric Compression

    Institute of Scientific and Technical Information of China (English)

    潘金龙; 鲁冰; 顾大伟; 夏正昊; 夏天阳

    2015-01-01

    In order to improve the seismic performance, deformation ability and ultimate load-carrying capacity of columns with rectangular cross section, engineered cementitious composite (ECC) is introduced to partially substitute concrete in the edge zone of reinforced concrete columns and form reinforced ECC/concrete composite columns. Firstly, based on the assumption of plane remaining plane and the simplified constitutive models, the calculation method of the load-carrying capacity of reinforced ECC/concrete columns is proposed. The stress and strain distribu-tions and crack propagation of the composite columns in different states of eccentric compressive loading are ana-lyzed. Then, nonlinear finite element analysis is conducted to study the mechanical performance of reinforced ECC/concrete composite columns with rectangular cross section. It is found that the simulation results are in good agreement with the theoretical results, indicating that the proposed method for calculating the load-carrying capacity of concrete/ECC composite columns is valid. Finally, based on the proposed method, the effects of ECC thickness, com-pressive strength of concrete and longitudinal reinforcement ratio on the mechanical performance of reinforced ECC/concrete composite columns are analyzed. Calculation results indicate that increasing the thickness of ECC layer or longitudinal reinforcement ratio can effectively increase the ultimate load-carrying capacity of the composite column with both small and large eccentricity, but increasing the strength of concrete can only increase the ultimate load-carrying capacity of the composite column with small eccentricity.

  15. Fat injection to correct contour deformities of the reconstructed breast: a single surgeon experience

    Directory of Open Access Journals (Sweden)

    Youssef Tahiri

    2015-06-01

    Full Text Available Aim: Autologous fat grafting has gained acceptance as a technique to improve aesthetic outcomes in breast reconstruction. The purpose of this study was to share our clinical experience using autologous fat injection to correct contour deformities during breast reconstruction. Methods: A single surgeon, prospectively maintained database of patients who underwent autologous fat injection during breast reconstruction from January 2008 to November 2013 at McGill University Health Center was reviewed. Patient characteristics, breast history, type of breast reconstruction, volume of fat injected, and complications were analyzed. Results: One hundred and twenty-four patients benefited from autologous fat injection from January 2008 to November 2013, for a total of 187 treated breasts. The patients were on average 49.3 years old (΁ 8.9 years. Fat was harvested from the medial thighs (20.5%, flanks (39.1%, medial thighs and flanks (2.9%, trochanters (13.3%, medial knees (2.7%, and abdomen (21.9%. An average of 49.25 mL of fat was injected into each reconstructed breast. A total of 187 breasts in 124 patients were lipo-infiltrated during the second stage of breast reconstruction. Thirteen breasts (in 12 separate patients were injected several years after having undergone lumpectomy and radiotherapy. Of the 187 treated breasts, 118 were reconstructed with expanders to implants, 45 with deep inferior epigastric perforator flaps, 9 with latissimus dorsi flaps with implants, 4 with transverse rectus abdominis myocutaneous flaps, and 13 had previously undergone lumpectomy and radiotherapy. Six complications were noted in the entire series, for a rate of 3.2%. All were in previously radiated breasts. Average follow-up time was 12 months (range: 2-36 months. Conclusion: Fat injection continues to grow in popularity as an adjunct to breast reconstruction. Our experience demonstrates a low complication rate as compared to most surgical interventions of the breast

  16. Analysis of cavity pressure and warpage of polyoxymethylene thin walled injection molded parts: Experiments and simulations

    Science.gov (United States)

    Guerrier, P.; Tosello, G.; Hattel, J. H.

    2015-05-01

    Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure, melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number of conclusions concerning improvements to simulation accuracy are presented regarding: pvT data, mesh, short shots, cavity pressure for process control validation as well as molding machine geometry modelling. Eventually, a methodology for improved molding simulations of cavity injection pressure, filling pattern and warpage was established.

  17. Combined group ECC protection and subgroup parity protection

    Energy Technology Data Exchange (ETDEWEB)

    Gara, Alan; Cheng, Dong; Heidelberger, Philip; Ohmacht, Martin

    2016-02-02

    A method and system are disclosed for providing combined error code protection and subgroup parity protection for a given group of n bits. The method comprises the steps of identifying a number, m, of redundant bits for said error protection; and constructing a matrix P, wherein multiplying said given group of n bits with P produces m redundant error correction code (ECC) protection bits, and two columns of P provide parity protection for subgroups of said given group of n bits. In the preferred embodiment of the invention, the matrix P is constructed by generating permutations of m bit wide vectors with three or more, but an odd number of, elements with value one and the other elements with value zero; and assigning said vectors to rows of the matrix P.

  18. Combined group ECC protection and subgroup parity protection

    Science.gov (United States)

    Gara, Alan G.; Chen, Dong; Heidelberger, Philip; Ohmacht, Martin

    2013-06-18

    A method and system are disclosed for providing combined error code protection and subgroup parity protection for a given group of n bits. The method comprises the steps of identifying a number, m, of redundant bits for said error protection; and constructing a matrix P, wherein multiplying said given group of n bits with P produces m redundant error correction code (ECC) protection bits, and two columns of P provide parity protection for subgroups of said given group of n bits. In the preferred embodiment of the invention, the matrix P is constructed by generating permutations of m bit wide vectors with three or more, but an odd number of, elements with value one and the other elements with value zero; and assigning said vectors to rows of the matrix P.

  19. [Combination surgery (ECCE+IOL+TE) and intraocular pressure levels].

    Science.gov (United States)

    Hornová, J

    1997-08-01

    The authors investigated the effect of a combined operation, ECCE + TE + IOL, on reduction of intraocular pressure (IOP), changes in antiglaucomatous treatment and on vision six months after operation. In 1994 36 eyes were operated, 16 eyes with primary open angle glaucoma (POAG), 8 eyes with angular glaucoma (PACG) and 12 eyes with marked exfoliative syndrome (CG). Six months after operation the IOP declined from 26.4 mm Hg to 13.3 mm Hg (P 0.05), antiglaucomatous treatment was reduced from 2.55 to 1.11 (P 0.05), vision improved by 0.39, i.e. by 2-3 lines of optotypes (P 0.05). 89% of the operated patients have a vision better than 0.5. Comparison of values before and after operation revealed a more marked drop of IOP in CG (P 0.05) than in POAG.

  20. Numerical analysis of experiments with gas injection into liquid metal coolant

    Science.gov (United States)

    Usov, E. V.; Lobanov, P. D.; Pribaturin, N. A.; Mosunova, N. A.; Chuhno, V. I.; Kutlimetov, A. E.

    2016-10-01

    Presented paper contains results of a numerical analysis of experiments with gas injection in water and liquid metal which have been performed at the Institute of Thermophysics Russian Academy of Science (IT RAS). Obtained experimental data are very important to predict processes that take place in the BREST-type reactor during the hypothetical accident with damage of the steam generator tubes, and may be used as a benchmark to validate thermo-hydraulic codes. Detailed description of models to simulate transport of gas phase in a vertical liquid column is presented in a current paper. Two-fluid model with closing relation for wall friction and interface friction coefficients was used to simulate processes which take place in a liquid during injection of gaseous phase. It has being shown that proposed models allow obtaining a good agreement between experimental data and calculation results.

  1. Interference of sulphur dioxide to balloon-borne ECC ozone sensors over the Valley of Mexico

    Directory of Open Access Journals (Sweden)

    I. Kanda

    2014-01-01

    Full Text Available Abnormal decrease in the ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City. Sharp drops around 5 km a.s.l. and above were observed in November 2011, and a broad deficit in the convective boundary layer in March 2012. Various circumstantial evidence indicates that the decrease was due to interference of SO2 gas to Electrochemical Concentration Cell (ECC ozone sensors. The sharp drops in November 2011 are considered to be caused by the SO2 plume from the Popocatépetl volcano to the south-east of Mexico City. Response experiments of the ECC sensor to representative atmospheric trace gases showed that only SO2 could generate the observed abrupt drops. The vertical structure of the plume reproduced by a Lagrangian particle diffusion simulation also supported this assumption. The near-ground deficit in March 2012 is considered to be generated by the SO2 plume from the Tula industrial complex to the north-west of Mexico City. Sporadic large SO2 emission is known to occur from this region, and before and at the ozonesonde launching time, large intermittent peaks of SO2 concentration were recorded at the ground-level monitoring stations. The difference between the O3 concentration obtained by ozonesonde and that by UV-based O3 monitor was consistent with the SO2 concentration measured by a UV-based monitor on the ground. The plume vertical profiles estimated by the Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in Mexico City revealed that the Popocatépetl effect is most likely to occur from June to October, and the Tula effect all the year.

  2. Interference of sulphur dioxide to balloon-borne ECC ozone sensors over the Valley of Mexico

    Science.gov (United States)

    Kanda, I.; Basaldud, R.; Horikoshi, N.; Okazaki, Y.; Benítez Garcia, S. E.; Ortínez, A.; Ramos Benítez, V. R.; Cárdenas, B.; Wakamatsu, S.

    2014-01-01

    Abnormal decrease in the ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City. Sharp drops around 5 km a.s.l. and above were observed in November 2011, and a broad deficit in the convective boundary layer in March 2012. Various circumstantial evidence indicates that the decrease was due to interference of SO2 gas to Electrochemical Concentration Cell (ECC) ozone sensors. The sharp drops in November 2011 are considered to be caused by the SO2 plume from the Popocatépetl volcano to the south-east of Mexico City. Response experiments of the ECC sensor to representative atmospheric trace gases showed that only SO2 could generate the observed abrupt drops. The vertical structure of the plume reproduced by a Lagrangian particle diffusion simulation also supported this assumption. The near-ground deficit in March 2012 is considered to be generated by the SO2 plume from the Tula industrial complex to the north-west of Mexico City. Sporadic large SO2 emission is known to occur from this region, and before and at the ozonesonde launching time, large intermittent peaks of SO2 concentration were recorded at the ground-level monitoring stations. The difference between the O3 concentration obtained by ozonesonde and that by UV-based O3 monitor was consistent with the SO2 concentration measured by a UV-based monitor on the ground. The plume vertical profiles estimated by the Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in Mexico City revealed that the Popocatépetl effect is most likely to occur from June to October, and the Tula effect all the year.

  3. Charge-carrier relaxation in disordered organic semiconductors studied by dark injection: Experiment and modeling

    Science.gov (United States)

    Mesta, M.; Schaefer, C.; de Groot, J.; Cottaar, J.; Coehoorn, R.; Bobbert, P. A.

    2013-11-01

    Understanding of stationary charge transport in disordered organic semiconductors has matured during recent years. However, charge-carrier relaxation in nonstationary situations is still poorly understood. Such relaxation can be studied in dark injection experiments, in which the bias applied over an unilluminated organic semiconductor device is abruptly increased. The resulting transient current reveals both charge-carrier transport and relaxation characteristics. We performed such experiments on hole-only devices of a polyfluorene-based organic semiconductor. Modeling the dark injection by solving a one-dimensional master equation using the equilibrium carrier mobility leads to a too-slow current transient, since this approach does not account for carrier relaxation. Modeling by solving a three-dimensional time-dependent master equation does take into account all carrier transport and relaxation effects. With this modeling, the time scale of the current transient is found to be in agreement with experiment. With a disorder strength somewhat smaller than extracted from the temperature-dependent stationary current-voltage characteristics, also the shape of the experimental transients is well described.

  4. Effects of Water Injection into Fractured Geothermal Reservoirs: A Summary of Experience Worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Horne, Roland N.

    1982-06-01

    Reinjection of water into fractured geothermal reservoirs holds potential both for improvement and degradation of total energy recovery. The replacement of reservoir fluid can mean support of placement of reservoir pressures and also more efficient thermal energy recovery, but at the same time the premature invasion of reinjected water back into production wells through high permeability fractures can reduce discharge enthalpy and hence deliverability and useful energy output. Increases in reservoir pressure and maintenance of field output have been observed in operating fields, but unfortunately so too have premature thermal breakthroughs. The design of reinjection schemes, therefore, requires careful investigation into the likely effects, using field experimentation. This paper summarizes field experience with reinjection around the world, with the intention of elucidating characteristics of possible problems. The results summarized in this paper fall into three categories of interest: permeability changes dye to injection (both increases and decreases); the path followed by injected water (as indicated by tracer tests); and the thermal and hydraulic influences of injection on the reinjection well itself and on surrounding producers. [DJE-2005

  5. Design calculations for a combined ventilation and brine injection experiment at the Grimsel Rock Laboratory, Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Finsterle, S.; Pruess, K.

    1993-07-01

    A combined ventilation and brine injection test is planned at the Grimsel Test Site. The objective of the experiment is to study the transport of liquid and gas in the vicinity of a ventilated drift in order to evaluate the impact of the drying process on the characterization of the rock matrix. The proposed test sequence includes a desaturation-resaturation cycle. In addition, brine and fresh water will be injected from a borehole as trace electrolytes in order to better track the propagation of the individual phases. Results of design calculations using the TOUGH2 code show that injection of brine may significantly influence the unsaturated flow behavior by changing the pressure and saturation distribution around the borehole. Transport velocity is predicted to be very slow, requiring several months for the brine to reach the draft wall. However, the presence of preferential flow paths may reduce travel time and alter brine content and saturation distribution so that certain sensors may respond earlier or not at all.

  6. The Experiment Research of Subconjunctival Injections with Etoposide for the Treatment of Retinoblastoma Mice

    Institute of Scientific and Technical Information of China (English)

    Yuxiang Mao; Zhongyao Wu; Huasheng Yang; Jianliang Zheng; Jianfeng He; Wei Li

    2005-01-01

    Purpose: To evaluate the efficacy of subconjunctival injections of Etoposide for retinoblastoma(RB) mice.Method: Twenty-five RB mice were divided into 5 groups for the study(G0~G4). GO for control group received 0.9% sodium chloride injection subconjunctival. G1: 5 RB mice for systemic delivery received 6 systemic administration of Etoposide 150 μg and Cyclosporin A (CSA)1.0mg at 3 days intervals, respectively. G2~G4:5 RB mice in each group received 6 subconjunctival delivery of Etoposide in 50、75、150μg at 3 days intervals, respectively.To observe the changes of the volume of RB in anterior chamber and the part of conjunctiva for injections of chemotherapeutic drugs. All eyes and conjunctiva and scleras of the part for drugs injections were obtained at 6 weeks after experiment for histopathologic examination. The findings under the light microscope were analysed with software to measure the areas of RB in anterior chambers and the tumor inhibition rate.Results:The volume of RB in anterior chambers for G1 and G2 increase quickly and none of the mice exhibited tumor control. The RB volume increase slowly in G3 and exhibit tumor control in G4. The areas of tumors in G0~G4 are 0.710,0.659,0.634,0.515,0.235 mm2, respectively. The rate for tumor inhibition in G0~G4 are 0.0%,7.18%, 10.70% ,27.43% ,66.90%, respectively. There are statistical significant difference between the G1 and G4 for the volumes of tumors and the rate of tumor inhibition.The pathologic examination of subconjunctiva and sclera for the injective sites showed no pathologic changes.Conclusions: There are significant effects for the method of subconjunctival delivery of Etoposide in RB control, demonstrating a positive dose-related relationship. Subconjunctival injection of Etoposide reached better efficacy in controlling and inhibiting RB cells than systemic delivery of Etoposide for the same dose. The pathologic results showed the subconjunctival delivery of etoposide were safety for

  7. Refractive results after phacoemulsification and ECCE. A comparative study.

    Science.gov (United States)

    Dam-Johansen, M; Olsen, T

    1993-06-01

    The refractive results were evaluated in 79 patients undergoing cataract extraction by phacoemulsification using a 6-7 mm tunnel incision, and compared with a group of 77 patients undergoing planned extracapsular cataract extraction (ECCE) by the same surgeon. A mean increase in the keratometric cylinder of 0.05D and 0.52D was found in the phacoemulsification and the extracapsular cataract extraction group, respectively. This was significantly different from zero for the extracapsular cataract extraction group (p 0.05). By vector analysis, the mean surgically induced astigmatism was 0.91D and 1.36D in the phacoemulsification and the extracapsular cataract extraction group, respectively (p < 0.01). The IOL power prediction error (spectacle plane) was found to be 0.17D (+/- 0.69 SD) in the phacoemulsification group and 0.02 D (+/- 0.79 SD) in the extracapsular cataract extraction group, respectively. We conclude that phacoemulsification improves the surgical control of the refractive outcome of cataract surgery.

  8. Incarceration experiences among a community-recruited sample of injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Lai Calvin

    2009-12-01

    Full Text Available Abstract Background Since 2003 Thailand has waged an aggressive "war on drugs" campaign focused on arresting and incarcerating suspected drug users and dealers. However, little is known about incarceration experiences among IDU in the wake of the recent war on drugs. Therefore, we sought to examine incarceration experiences among IDU in Bangkok, Thailand. Methods We examined the prevalence of incarceration among community-recruited IDU participating in the Mitsampan Community Research Project. Multivariate logistic regression was used to identify factors associated with a self-reported history of incarceration. We also examined the prevalence of injection drug use and syringe sharing within prisons. Results 252 IDU were recruited in August 2008; 66 (26.2% were female and the median age was 36.5 years. In total, 197 (78.2% participants reported a history of incarceration. In multivariate analyses, reporting a history of incarceration was associated with a history of compulsory drug treatment (adjusted odds ratio [AOR] = 4.93; 95% confidence interval [CI]: 1.95 - 12.48, non-fatal overdose (AOR = 3.69; 95%CI: 1.45 - 9.39, syringe sharing (AOR = 2.20; 95%CI: 1.12 - 4.32, and female gender (AOR = 0.41; 95%CI: 0.20 - 0.82. Among those who reported a history of incarceration, 59 (29.9% reported injection drug use in prison, and 48 (81.4% of these individuals reported sharing syringes in prison. Incarceration was not associated with the number of injections performed in the previous week (p = 0.202. Conclusion Over three-quarters of the IDU participating in this study reported a history of incarceration, and 30% of these individuals reported injection drug use within prison. Further, an alarmingly high level of syringe sharing within prison was reported, and incarceration was not associated with reductions in drug use. These findings provide further evidence of the need for community diversion strategies, as well as harm reduction programs, in Thai

  9. Investigation of oil injection into brine for the strategic petroleum reserve : hydrodynamics experiments with simulant liquids.

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, Jaime N.; Shollenberger, Kim Ann (California Polytechnic State University, San Luis Obispo, CA); Torczynski, John Robert; Cote, Raymond O.; Barney, Jeremy; O' Hern, Timothy John

    2003-10-01

    An experimental program is being conducted to study a proposed approach for oil reintroduction in the Strategic Petroleum Reserve (SPR). The goal is to assess whether useful oil is rendered unusable through formation of a stable oil-brine emulsion during reintroduction of degassed oil into the brine layer in storage caverns. This report documents the first stage of the program, in which simulant liquids are used to characterize the buoyant plume that is produced when a jet of crude oil is injected downward from a tube into brine. The experiment consists of a large transparent vessel that is a scale model of the proposed oil injection process at the SPR. An oil layer is floated on top of a brine layer. Silicon oil (Dow Corning 200{reg_sign} Fluid, 5 cSt) is used as the simulant for crude oil to allow visualization of the flow and to avoid flammability and related concerns. Sodium nitrate solution is used as the simulant for brine because it is not corrosive and it can match the density ratio between brine and crude oil. The oil is injected downward through a tube into the brine at a prescribed depth below the oil-brine interface. Flow rates are determined by scaling to match the ratio of buoyancy to momentum between the experiment and the SPR. Initially, the momentum of the flow produces a downward jet of oil below the tube end. Subsequently, the oil breaks up into droplets due to shear forces, buoyancy dominates the flow, and a plume of oil droplets rises to the interface. The interface is deflected upward by the impinging oil-brine plume. Two different diameter injection tubes were used (1/2-inch and 1-inch OD) to vary the scaling. Use of the 1-inch injection tube also assured that turbulent pipe flow was achieved, which was questionable for lower flow rates in the 1/2-inch tube. In addition, a 1/2-inch J-tube was used to direct the buoyant jet upwards rather than downwards to determine whether flow redirection could substantially reduce the oil-plume size and the

  10. Application of Interfacial Propagation and Kinking Crack Concept to ECC/Concrete Overlay Repair System

    Directory of Open Access Journals (Sweden)

    Yaw ChiaHwan

    2014-01-01

    Full Text Available Research on the application of ultraductile engineered cementitious composite (ECC as overlay in the repair of deteriorated concrete structures is performed in this paper. Also, interfacial crack kinking and trapping mechanism experimentally observed in ECC/concrete overlay repair system are described by comparison of toughness and energy release rate. The mechanism involves cycles of extension, kinking, and arrest of interfacial crack into the overlay. Experimental testing of overlay repair system reveals significant improvements in load carrying capacity and ductility over conventional concrete overlay. The commonly observed overlay system failure mode of delamination or spalling is eliminated when ECC is applied. These failure modes are suppressed when ECC is used as an ideal and durable candidate overlay repair material.

  11. Preestrita pihtimus : Friedrich Nietzsche ja tema substantsiaalne mina (Ecce homo) / Jaan Undusk

    Index Scriptorium Estoniae

    Undusk, Jaan, 1958-

    1998-01-01

    Varem ilmunud raamatu järelsõnana: Nietzsche, Friedrich. Ecce homo : kuidas saadakse selleks, mis ollakse / tlk. Jaan Undusk. Tallinn : Vagabund, 1996. Sisu: Poeetiline, filosoofiline, dionüüsiline kaanon ; Künism contra hulluskahtlus ; Antikristlik pihtimus ; Egoretoorika

  12. Preestrita pihtimus : Friedrich Nietzsche ja tema substantsiaalne mina (Ecce homo) / Jaan Undusk

    Index Scriptorium Estoniae

    Undusk, Jaan, 1958-

    1998-01-01

    Varem ilmunud raamatu järelsõnana: Nietzsche, Friedrich. Ecce homo : kuidas saadakse selleks, mis ollakse / tlk. Jaan Undusk. Tallinn : Vagabund, 1996. Sisu: Poeetiline, filosoofiline, dionüüsiline kaanon ; Künism contra hulluskahtlus ; Antikristlik pihtimus ; Egoretoorika

  13. New External Calibration Curves (ECCs) for the Estimation of Molecular Weights in Various Common NMR Solvents.

    Science.gov (United States)

    Bachmann, Sebastian; Neufeld, Roman; Dzemski, Martin; Stalke, Dietmar

    2016-06-13

    New external calibration curves (ECCs) for the estimation of aggregation states of small molecules in solution by DOSY NMR spectroscopy for a range of different common NMR solvents ([D6 ]DMSO, C6 D12 , C6 D6 , CDCl3 , and CD2 Cl2 ) are introduced and applied. ECCs are of avail to estimate molecular weights (MWs) from diffusion coefficients of previously unknown aggregates. This enables a straightforward and elaborate examination of (de)aggregation phenomena in solution.

  14. Self-Healing of Microcracks in Engineered Cementitious Composites (ECC Under a Natural Environment

    Directory of Open Access Journals (Sweden)

    Victor C. Li

    2013-07-01

    Full Text Available This paper builds on previous self-healing engineered cementitious composites (ECC research by allowing ECC to heal outdoors, in the natural environment, under random and sometimes extreme environmental conditions. Development of an ECC material that can heal itself in the natural environment could lower infrastructure maintenance costs and allow for more sustainable development in the future by increasing service life and decreasing the amount of resources and energy needed for repairs. Determining to what extent current ECC materials self-heal in the natural environment is the first step in the development of an ECC that can completely heal itself when exposed to everyday environmental conditions. This study monitored outdoor ECC specimens for one year using resonant frequency (RF and mechanical reloading to determine the rate and extent of self-healing in the natural environment. It was found that the level of RF, stiffness, and first cracking strength recovery increased as the duration of natural environment exposure increased. For specimens that underwent multiple damage cycles, it was found that the level of recovery was highly dependent on the average temperature and amount of precipitation between each damage event. However, RF, stiffness, and first cracking strength recovery data for specimens that underwent multiple loading cycles suggest that self-healing functionality can be maintained under multiple damage events.

  15. Self-Healing of Microcracks in Engineered Cementitious Composites (ECC) Under a Natural Environment.

    Science.gov (United States)

    Herbert, Emily N; Li, Victor C

    2013-07-15

    This paper builds on previous self-healing engineered cementitious composites (ECC) research by allowing ECC to heal outdoors, in the natural environment, under random and sometimes extreme environmental conditions. Development of an ECC material that can heal itself in the natural environment could lower infrastructure maintenance costs and allow for more sustainable development in the future by increasing service life and decreasing the amount of resources and energy needed for repairs. Determining to what extent current ECC materials self-heal in the natural environment is the first step in the development of an ECC that can completely heal itself when exposed to everyday environmental conditions. This study monitored outdoor ECC specimens for one year using resonant frequency (RF) and mechanical reloading to determine the rate and extent of self-healing in the natural environment. It was found that the level of RF, stiffness, and first cracking strength recovery increased as the duration of natural environment exposure increased. For specimens that underwent multiple damage cycles, it was found that the level of recovery was highly dependent on the average temperature and amount of precipitation between each damage event. However, RF, stiffness, and first cracking strength recovery data for specimens that underwent multiple loading cycles suggest that self-healing functionality can be maintained under multiple damage events.

  16. Mesigyna once-a-month combined injectable contraceptive: experience in Latin America.

    Science.gov (United States)

    Bassol, S; Cravioto, M C; Durand, M; Bailon, R; Carranza, S; Fugarolas, J; Gaona, R; Parada, L M; Celis, C; Santoyo, S; Garza-Flores, J; Vazquez, L; Lopez, C; Gurucharri, C; Novelli, J; Carneiro de Oliveira, H; Mendez, J; de Andrade, M E; de Mello, N R; de Melo, K; Chada, E; Yassle, M E; Castañeda, A; Gomez, P; Arboleda, C; Trujillo, L; Bucheli, R; Hidalgo, I; Olavide, R; Parejarios, J; Succar, J; Reyes-Marquez, R; Albrecht, G

    2000-05-01

    A phase III clinical study was carried out among 534 fertile Latin American women to evaluate cycle control, side effects, and contraceptive efficacy of a once-a-month combined injectable, Mesigyna, consisting of 50 mg norethisterone enanthate and 5 mg estradiol valerate. The pregnancy rate at 1 year was 0 per 100 woman-years for a total experience of 4688 woman-months. The overall discontinuation rate at one year was 17.9%. Discontinuation rate for bleeding problems was 5.1%. The Colombian women had a significant increase (p <0.001) in bleeding problems compared to other countries. The discontinuation rate for amenorrhea was 1.1%. There were no significant differences between the groups regarding discontinuation for other medical or non-medical reasons. Mean weight gain after one year of use was 1.02 kg. Mesigyna is an appropiate once-a-month injectable contraceptive for Latin American women since it is highly effective and its perception of normal menstrual bleeding is of importance in the Latin American population.

  17. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego.

    Science.gov (United States)

    Wood, Emily F; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Cuevas Mota, Jazmine; Garfein, Richard S; Strathdee, Steffanie A; Wagner, Karla D

    2017-03-01

    powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. The pharmacodynamics experiment of XinHua injection protect action of ADR-induced toxin myocarditisin mice

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong; DU Jia-lin; LI Xin-hua; XIANG Shao-jie; JIA Dong; BAO Yu-long; LI Kun

    2008-01-01

    Objective The experiment is to study the protective effects of Xinkang Injection on ADR-induced toxin myocarditisin mice. Methods The test of Xinkang Injection on ADR-induced toxin myocarditisin mice. Firstly, the animal of obnormal, weight and death rate. Secondly, the influnences of cardiogram of ADR-induced toxin myocarditisin mice. Thirdly, the influnences of lactate dehydrogenase (LDH), creatine kinase (CK) and glutamic oxaloacetic transaminasw (GOT) of ADR-induced toxin myocarditisin mice. Fouthly, the influnences of changes of cardioc pathological mechanism of ADR-induced toxin myocarditisin mice. Fifthly, the influnces of the caidioc ultrastructural of ADR-induced toxin myocarditisin mice. Results Firstly, to ADR-induced toxin myocarditisin mice, the weight of middle dose and high dose of Xinkang injection had declined obviosly which contrast with the constraction model mice team. In the mean time, the weight of Xinkang injection team had obviosly changde which contrast with contrastion mice team(P<0.01 ). Secondly, to ADR-induced toxin myocarditisin mice, the middle dose and high dose of Xinkang injection have obviosly withstand Q abnormal cardiogram, in the meantime, Xinkang injection team had obviosly changde contrast with the contrastion model mice (P<0.01 ). Thirdly, to ADR-induced toxin myocarditisin mice, The activity of lactate dehydrogenase(LDH),creatine kinase (CK) and glutamic oxaloacetic transaminasw (GOT) were differently measured. The middle dose and high dose of Xinkang injection team can obviously declined the activity of LDH and CK (P<0.01). Fouthly, to ADR-induced toxin myocarditisin mice, the low dose, the middle dose and high dose of Xinkang injection team can contrast w, ith injured on toxic myocarditisin mice cardioc. Fifthly, to ADR-induced toxin myocarditisin mice, the low dose , the middle dose and high dose of Xinkang injection team have effect of allevite the injection of the cardioc ulteasteuctural of ADR-induced toxin

  19. Laboratory Experiments on Environmental Friendly Means to Improve Coalbed Methane Production by Carbon Dioxide/Flue Gas Injection

    NARCIS (Netherlands)

    Mazumder, S.; Wolf, K.H.A.A.; Van Hemert, P.; Busch, A.

    2008-01-01

    Scaled in situ laboratory core flooding experiments with CO2, N2 and flue gas were carried out on coal in an experimental high P,T device. These experiments will be able to give an insight into the design of the injection system, management, control of the operations and the efficiency of an ECBM pr

  20. Laboratory Experiments on Environmental Friendly Means to Improve Coalbed Methane Production by Carbon Dioxide/Flue Gas Injection

    NARCIS (Netherlands)

    Mazumder, S.; Wolf, K.H.A.A.; Van Hemert, P.; Busch, A.

    2008-01-01

    Scaled in situ laboratory core flooding experiments with CO2, N2 and flue gas were carried out on coal in an experimental high P,T device. These experiments will be able to give an insight into the design of the injection system, management, control of the operations and the efficiency of an ECBM

  1. 基于FPGA的椭圆曲线密码(ECC)算法硬件设计%Hardware Design of Elliptic Curve Cryptography(ECC) Based on FPGA

    Institute of Scientific and Technical Information of China (English)

    赵曼; 徐和根

    2013-01-01

    Elliptic curve cryptosystem ( ECC) is a public key encryption system with the most secure unit key security at present, the application of FPGA and hardware design to implement the ECC cryptography have become a concern in the field of information security. The further study of the elliptic curve encryption and decryption is based on the theory, using the verilog hardware description language and schematic design method to achieve the ECC encryption algorithm, with high-speed and low-power characteristics.%椭圆曲线密码体制(elliptic curve cryptosystem,ECC)是目前已知的单位密钥安全性最高的一种公钥加密体制,使用FPGA等硬件设计方法来实现ECC密码系统已成为信息安全领域引人关注的研究.该文在深入研究椭圆曲线加解密理论基础上,使用Verilog硬件描述语言和原理图输入法共同实现了ECC加密算法,具有高速、低功耗的特点.

  2. Local mechanical properties of LFT injection molded parts: Numerical simulations versus experiments

    Science.gov (United States)

    Desplentere, F.; Soete, K.; Bonte, H.; Debrabandere, E.

    2014-05-01

    In predictive engineering for polymer processes, the proper prediction of material microstructure from known processing conditions and constituent material properties is a critical step forward properly predicting bulk properties in the finished composite. Operating within the context of long-fiber thermoplastics (LFT, length Autodesk Simulation Moldflow Insight 2014 software has been used. In this software, a fiber breakage algorithm for the polymer flow inside the mold is available. Using well known micro mechanic formulas allow to combine the local fiber length with the local orientation into local mechanical properties. Different experiments were performed using a commercially available glass fiber filled compound to compare the measured data with the numerical simulation results. In this investigation, tensile tests and 3 point bending tests are considered. To characterize the fiber length distribution of the polymer melt entering the mold (necessary for the numerical simulations), air shots were performed. For those air shots, similar homogenization conditions were used as during the injection molding tests. The fiber length distribution is characterized using automated optical method on samples for which the matrix material is burned away. Using the appropriate settings for the different experiments, good predictions of the local mechanical properties are obtained.

  3. A discrete choice experiment to determine patient preferences for injection devices in multiple sclerosis.

    Science.gov (United States)

    Shingler, S L; Swinburn, P; Ali, S; Perard, R; Lloyd, A J

    2013-08-01

    Relapsing-remitting multiple sclerosis (MS) is usually managed with disease modifying drugs (DMDs), most commonly administered via self-injection. The aim of this study was to estimate the influence that different treatment-related attributes have for MS patients on their choice of MS DMD device. By establishing the relative importance of these characteristics for patients it should be possible to better understand the acceptability of a given device and to optimize the development of future devices. A discrete choice experiment (DCE) survey was developed on the basis of a review of published literature. Attributes identified for inclusion in the survey were: ease of use; comfort of use; presence of additional functions, needle visibility; practicality and efficacy. Choice sets were presented as pairs of hypothetical treatments based upon a fractional factorial design. One-hundred device-using MS patients completed the survey online. Analysis was conducted using a mixed-logit approach. Analysis of the DCE data revealed that all attributes significantly predicted treatment choice. Efficacy exhibited the largest effect on treatment selection and this provided context for understanding the magnitude of impact for the other attributes. Reducing the discomfort associated with device use and eliminating the necessity for assembly or drug reconstitution were highly valued. The addition of reminder and time-stamping functions, improved needlestick injury prevention, and reduction in device size were secondary concerns but still deemed desirable. Efficacy is of primary importance to MS patients, but characteristics of drug delivery devices can play an important role in treatment decision-making. Not all device characteristics could be included, and results are based upon 100 participants only. Findings suggest there is significant potential value in developing self-injection devices that are not only efficacious but also convenient and comfortable to use. Reducing barriers

  4. Simulation of field injection experiments in heterogeneous unsaturated media using cokriging and artificial neural network

    Science.gov (United States)

    Ye, Ming; Khaleel, Raziuddin; Schaap, Marcel G.; Zhu, Jianting

    2007-07-01

    Simulations of moisture flow in heterogeneous soils are often hampered by lack of measurements of soil hydraulic parameters, making it necessary to rely on other sources of information. In this paper, we develop a methodology to integrate data that can be easily obtained (for example, initial moisture content, θi, bulk density, and soil texture) with data on soil hydraulic properties via cokriging and Artificial Neural Network (ANN)-based pedotransfer functions. The method is applied to generate heterogeneous soil hydraulic parameters at a field injection site in southeastern Washington State. Stratigraphy at the site consists of imperfectly stratified layers with irregular layer boundaries. Cokriging is first used to generate three-dimensional heterogeneous fields of bulk density and soil texture using an extensive data set of field-measured θi, which carry signature about site heterogeneity and stratigraphy. Soil texture and bulk density are subsequently input into an ANN-based site-specific pedotransfer function to generate three-dimensional heterogeneous soil hydraulic parameter fields. The stratigraphy at the site is well represented by the estimated pedotransfer variables and soil hydraulic parameters. The parameter estimates are then used to simulate a field injection experiment at the site. A relatively good agreement is obtained between the simulated and observed moisture contents. The spatial distribution pattern of observed moisture content as well as the southeastward moisture movement is captured well in the simulations. In contrast to earlier work using an effective parameter approach (Yeh et al., 2005), we are able to reproduce the observed splitting of the moisture plume in a coarse sand unit that is sandwiched between two fine-textured units. The simple method of combining cokriging and ANN for site characterization provides unbiased prediction of the observed moisture plume and is flexible so that additional measurements of various types can be

  5. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Energy-dissipating and self-repairing SMA-ECC composite material system

    Science.gov (United States)

    Li, Xiaopeng; Li, Mo; Song, Gangbing

    2015-02-01

    Structural component ductility and energy dissipation capacity are crucial factors for achieving reinforced concrete structures more resistant to dynamic loading such as earthquakes. Furthermore, limiting post-event residual damage and deformation allows for immediate re-operation or minimal repairs. These desirable characteristics for structural ‘resilience’, however, present significant challenges due to the brittle nature of concrete, its deformation incompatibility with ductile steel, and the plastic yielding of steel reinforcement. Here, we developed a new composite material system that integrates the unique ductile feature of engineered cementitious composites (ECC) with superelastic shape memory alloy (SMA). In contrast to steel reinforced concrete (RC) and SMA reinforced concrete (SMA-RC), the SMA-ECC beams studied in this research exhibited extraordinary energy dissipation capacity, minimal residual deformation, and full self-recovery of damage under cyclic flexural loading. We found that the tensile strain capacity of ECC, tailored up to 5.5% in this study, allows it to work compatibly with superelastic SMA. Furthermore, the distributed microcracking damage mechanism in ECC is critical for sufficient and reliable recovery of damage upon unloading. This research demonstrates the potential of SMA-ECC for improving resilience of concrete structures under extreme hazard events.

  7. Holistic care patient with Early Childhood Caries (ECC: A case report

    Directory of Open Access Journals (Sweden)

    Intan Maulani

    2016-06-01

    Full Text Available Early Childhood Caries (ECC is a specific form of severe dental caries that affects infants and young children. ECC progresses rapidly in those who are at high risk, and often goes untreated. Children experiencing caries as infants or toddlers have a much greater probability of subsequent caries in both primary and permanent dentitions. This case showed management holistic care for children with ECC.A five year old boy patient accompanied with her parents were reported to the Pedodontic Clinic Padjadjaran University Dental Hospital with a chief complaint of decayed upper anterior teeth and pain in the molar teeth. Clinical examinations found dental caries almost all teeth in the maxilla and mandible. Based on panoramic radiograph, treatments that can be done are strip crown glass ionomer restorations, pulp treatments, extractions and fixed space maintainer. Patients diagnosed with severe ECC, patient and parents described on this type of caries. During treatment the patient was given oral hygiene instruction and recommend daily use of tooth mouse. After all treatment were completed, fluoride topical, and fissure sealants, recall check up after three months was scheduled. Holistic care needed in handling children with ECC.

  8. Comparison of outcomes following combined ECCE-trabeculectomy versus phacoemulsification-trabeculectomy.

    Science.gov (United States)

    Tous, Horacio M; Nevárez, Juan

    2006-12-01

    To analyze and compare the main outcomes between trabeculectomies combined with extracapsular cataract extraction (ECCE) versus those with phacoemulsification (Phaco). The authors retrospectively reviewed one surgeon's 357 consecutive cases (475 eyes) of combined cataract extraction, intraocular lens implantation and Mitomycin enhanced trabeculectomy. Patients were divided into two groups, those who underwent extracapsular cataract extraction (80 eyes) and those having phacoemulsification (395 eyes). Analysis of postoperative visual acuity, intraocular pressure (IOP), number of glaucoma medications, postoperative adverse events and additional procedures required, was done. Minimum follow-up was 12 months with an average of 53 months. There was no significant difference (p = 1.000) between the groups in terms of visual acuity improvement rate, 66% (ECCE) versus 59% (Phaco). Postoperatively IOP with both techniques fell significantly (p ECCE vs. 14.1 mmHg Phaco, p = 1.0000). Postoperative pressure spikes occurred in 6% versus 10% (p = 0.3995) of the eyes. No significant difference (55% ECCE versus 63% Phaco, p = 0.1674) between the two groups in terms of glaucoma medication reduction was found. The total number of postoperative complications (89% versus 68.5%) were significantly higher (p = 0.0001) in the ECCE-group, as well as the total number of eyes which required further interventions (86% versus 64%, p = 0.0001). Both combined surgery techniques are effective and yielded similar long-term results. However phacoemulsification can decrease the post operative complications associated with this surgery.

  9. Hydrogeological characterization of the Heletz Sands Reservoir, Heletz (Israel) as a preliminary step towards CO2 injection experiments

    Science.gov (United States)

    Bensabat, Jacob; Niemi, Auli; Tsang, Chin-Fu; Sharma, Prabhakar; Carrera, Jesus; Sauter, Martin; Tatomir, Alexandru; Ghergut, Julia; Pezard, Philippe; Edlman, Katriona; Brauchler, Ralf

    2013-04-01

    Hydrogeological characterization of the Heletz Sands Reservoir, Heletz (Israel) as a preliminary step towards CO2 injection experiments One the major components of the EU-FP7 funded MUSTANG project is to conduct a highly controlled series of CO2 injection experiments, aimed at determining field values of key CO2 trapping mechanisms such as dissolution and residual trapping and to establish a comprehensive and consistent dataset for model validation. Prior to injecting CO2 there is a need to achieve a sufficient degree of hydrogeological characterization of the reservoir. In what follows we present a sequence of hydrologic tests to be conducted at Heletz and their expected contribution to the understanding relevant hydrogeology. These include: 1) Chemical characterization of the formation fluid; 2) Flowing Fluid Electrical Conductivity log, aimed at determining the vertical variability of the reservoir permeability in the near well vicinity; 3) Water pulse and pumping tests, aimed at determining the reservoir scale hydraulic properties; 4) Thermal test, aimed at determining the value of the heat transfer coefficient from the reservoir to the borehole fluid, which is responsible for the heating of injected fluid in the borehole; 5) two-well injection and pumping of water and tracers test, in order to determine the impact of heterogeneity on the hydraulic parameters and to identify preferential flow paths in the reservoir. This paper presents the design and planning of the experiments, the results obtained in field and a preliminary interpretation.

  10. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  11. Neutral Beam Injection System for the C-2W Field Reversed Configuration Experiment

    Science.gov (United States)

    Dunaevsky, Alexander; Ivanov, Alexander; Kolmogorov, Vyacheslav; Smirnov, Artem; Korepanov, Sergey; Binderbauer, Michl; TAE Team; BINP Team

    2016-10-01

    C-2U Field-Reversed Configuration (FRC) experiment proved substantial reduction in turbulence-driven losses via tangential neutral beam injection (NBI) coupled with electrically biased plasma guns at the plasma ends. Under such conditions, highly reproducible, advanced beam-driven FRCs were produced and sustained for times significantly longer (more than 5 ms) than all characteristic plasma decay times without beams. To further improve FRC sustainment and demonstrate the FRC ramp-up, the C-2U experimental device is undergoing a major upgrade. The upgrade, C-2W, will have a new NBI system producing a record total hydrogen beam power of 20 + MW in a 30ms pulse. The NBI system consists of eight positive-ion based injectors featuring flexible, modular design. Four out of eight NBI injectors have a capability to switch the beam energy during a shot from the initial 15 keV to 40 keV at a constant beam current. This feature allows to increase the beam energy and thereby optimize the beam-plasma coupling during the magnetic field ramp up. This presentation provides an overview of the C-2W NBI system, including the design of the switchable energy injectors, layout of the power supply system, and results of the prototype testing.

  12. Blood Trials: Transfusions, Injections, and Experiments in Africa, 1890-1920.

    Science.gov (United States)

    Sunseri, Thaddeus

    2016-07-01

    From about 1880 to 1920, a culture of medical experimentation promoted blood transfusion as a therapy for severe anemia in Europe, which was applied in German East Africa in 1892 for a case of blackwater fever, a complication of malaria afflicting mainly Europeans. This first case of blood transfusion in Africa, in which an African's blood was transfused into a German official, complicates the dominant narrative that blood transfusions in Africa came only after World War I. Medical researchers moreover experimented with blood serum therapies on human and animal subjects in Europe and Africa, injecting blood of different species, "races" and ethnicities into others to demonstrate parasite transmissibility and to discover vaccines for diseases such as malaria, sleeping sickness, and yellow fever. While research in German colonies is highlighted here, this was a transnational medical culture that crossed borders and oceans. This research is of interest as a possible early pathway for the epidemic spread of HIV and other zoonoses in Africa and the world, which biomedical researchers have identified as emerging in West-Central Africa sometime around the turn of the twentieth century.

  13. Experiences with Policing among People Who Inject Drugs in Bangkok, Thailand: A Qualitative Study

    Science.gov (United States)

    Hayashi, Kanna; Small, Will; Csete, Joanne; Hattirat, Sattara; Kerr, Thomas

    2013-01-01

    Background Despite Thailand's commitment to treating people who use drugs as “patients” not “criminals,” Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID) in Bangkok, Thailand, between 2008 and 2012. Methods and Findings Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample. Conclusions This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings

  14. Experiences with policing among people who inject drugs in Bangkok, Thailand: a qualitative study.

    Science.gov (United States)

    Hayashi, Kanna; Small, Will; Csete, Joanne; Hattirat, Sattara; Kerr, Thomas

    2013-12-01

    Despite Thailand's commitment to treating people who use drugs as "patients" not "criminals," Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID) in Bangkok, Thailand, between 2008 and 2012. Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample. This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings pertaining to the use of urine drug testing by police

  15. Experiences with policing among people who inject drugs in Bangkok, Thailand: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Kanna Hayashi

    2013-12-01

    Full Text Available Despite Thailand's commitment to treating people who use drugs as "patients" not "criminals," Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID in Bangkok, Thailand, between 2008 and 2012.Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample.This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings pertaining to the use of urine drug

  16. Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

    Directory of Open Access Journals (Sweden)

    Li Yuquan

    2017-02-01

    Full Text Available The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA, the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the

  17. Lightweight ECC based RFID authentication integrated with an ID verifier transfer protocol.

    Science.gov (United States)

    He, Debiao; Kumar, Neeraj; Chilamkurti, Naveen; Lee, Jong-Hyouk

    2014-10-01

    The radio frequency identification (RFID) technology has been widely adopted and being deployed as a dominant identification technology in a health care domain such as medical information authentication, patient tracking, blood transfusion medicine, etc. With more and more stringent security and privacy requirements to RFID based authentication schemes, elliptic curve cryptography (ECC) based RFID authentication schemes have been proposed to meet the requirements. However, many recently published ECC based RFID authentication schemes have serious security weaknesses. In this paper, we propose a new ECC based RFID authentication integrated with an ID verifier transfer protocol that overcomes the weaknesses of the existing schemes. A comprehensive security analysis has been conducted to show strong security properties that are provided from the proposed authentication scheme. Moreover, the performance of the proposed authentication scheme is analyzed in terms of computational cost, communicational cost, and storage requirement.

  18. Intraocular pressure following ECCE and IOL implantation in patients with glaucoma.

    Science.gov (United States)

    Kooner, K S; Dulaney, D D; Zimmerman, T J

    1988-08-01

    Patients with glaucoma may suffer optic nerve head damage due to elevated intraocular pressure (IOP) after any intraocular procedure. We retrospectively reviewed the IOP data in 82 consecutive patients (103 eyes) with glaucoma after extracapsular cataract extraction (ECCE) and posterior chamber intraocular lens (PC-IOL) implantation. Nine eyes had previous trabeculectomy and three eyes required combined trabeculectomy with ECCE and PC-IOL. The average follow-up period is 1.5 years (range 0.5 to 6 years). The postoperative IOP rise of 8 mm Hg over baseline or above 23 mm Hg was observed in 45 eyes (49.5%). Two eyes needed argon laser trabeculoplasty and one required trabeculectomy to control postoperative IOP elevation. Most of the patients required the same or lesser number of medications for IOP control after surgery. Results suggest that ECCE with PC-IOL may be a relatively safe procedure in cataract patients with preexisting glaucoma.

  19. Feasibility study of a Single Well Injection Withdrawal (SWIW) experiment with synthetic groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Nordqvist, Rune; Byegaard, Johan; Hjerne, Calle (Geosigma AB, Uppsala (Sweden))

    2008-08-15

    This report describes the performance and results of a feasibility study regarding SWIW (Single Well Injection Withdrawal) tests with synthetic groundwater. The objectives of the study were to investigate the possibility to perform, analyse and evaluate SWIW tests with synthetic groundwater. SWIW tests with synthetic groundwater imply that water similar to the natural groundwater is produced but without one or several compounds that naturally occurs in the groundwater. The synthetic groundwater is injected into the rock formation and later pumped back. The increase of the naturally occurring compounds may be analysed and provide information about diffusion processes in the rock formation. Simulations of SWIW tests with synthetic groundwater shows that a combination of tests with and without a waiting period may provide good opportunities to distinguish between fast and slow diffusion processes, i.e. diffusion from stagnant zones and rock matrix. Furthermore, the simulations show that it is important to use many tracers with different characteristics regarding diffusion and sorption in order to facilitate the evaluation. If additional boreholes exist in the vicinity that may be used as observation holes for tracer breakthrough, it would be a great benefit for the evaluation of the tests. This study shows that it is possible to produce a synthetic groundwater of sufficient amount and purity to a reasonable cost at CLAB (Baslab). The starting point for the study was to use the test site TRUE Block Scale in the Aespoe tunnel. The study shows that the well characterized structures no 19 and 20 probably had been suitable for SWIW tests. However, during the feasibility study a project started that will result in a new tunnel in the vicinity of TRUE Block Scale. This implies that the site will not be accessible for experiments until 2009 at the earliest. The new tunnel may also change the hydraulic characteristics at the site so that it is no longer suitable for SWIW tests

  20. Clinical outcomes and costs of cataract surgery performed by planned ECCE and phacoemulsification.

    Science.gov (United States)

    Castells, X; Comas, M; Castilla, M; Cots, F; Alarcón, S

    1998-01-01

    To compare clinical outcomes and costs of cataract surgery between patients operated with standard extracapsular extraction (ECCE) and those undergoing phacoemulsification. Patients from the Ophthalmology Department of a teaching hospital in Barcelona (Spain) scheduled for cataract surgery, not combined with any other ophthalmic procedure. A retrospective analysis has been performed on a database of 1046 patients undergoing ECCE and phacoemulsification. The outcome measures used were: surgical complications, visual acuity and costs of surgery and of follow-up. Overall rate of all complications and postoperative visual acuity were compared between the two groups, adjusting for age, preoperative visual acuity, medical and ocular comorbidity. 31.9% of the patients (334) underwent phacoemulsification, and 68.1% (712) underwent ECCE. Patients undergoing phacoemulsification presented a frequency of intra- and postoperative complications lower than those undergoing ECCE (odds ratio 0.57, 95%CI 0.37-0.87 and 0.66, 95%CI 0.46-0.96, respectively), specifically for intraoperative iris trauma (3.1% vs 0.3%, p = 0.004), residual posterior capsular opacity (2% vs 0.3%, p = 0.035) and postoperative corneal edema (7.4% vs 3.6%, p = 0.016). Costs of intervention and follow-up were lower for phacoemulsification compared with ECCE (23.9% and 14%, respectively). But global costs were slightly higher for phacoemulsification (4.87%), due to supply costs, which were more than twice those of ECCE. Phacoemulsification, when performed by an experienced surgeon, has better clinical outcomes than planned extracapsular extraction, and costs may be lower since supply costs are expected to decrease as the phacoemulsification technique becomes more widespread.

  1. BREASTFEEDING AND EARLY CHILDHOOD CARIES (ECC SEVERITY OF CHILDREN UNDER THREE YEARS OLD IN DKI JAKARTA

    Directory of Open Access Journals (Sweden)

    Risqa Rina Darwita

    2008-12-01

    Full Text Available The prevalence and severity of caries in children under three years old are constantly increasing. One of the cause is the increase consumption of cariogenic carbohydrate. Breast milk have buffer capacity that eventually able to prevent caries. The aims of this research are to discover the correlation between breastfeeding with the severity of Early Childhood Caries (ECC in children under three years old, to provide information on prevalence and severity of caries in children under three years, and to explain factors influencing the incidence of ECC. This research designed cross sectionally and conducted upon 565 children aged 12-38 months, selected using multistage cluster random sampling. The ECC prevalence of children under three years in DKI Jakarta is 52.7%, with average score of def-t 2.85. Bivariate analysis showed that, variables which correlate with the level of ECC are; the way to deliver (p=0,012, frequency (p=0,002, duration (p=0,002, salivary buffer capacity (p=0.013, habitual consumption of sugary diet (p=0.005, child’s dental hygiene behavior (p=0.002, and mother’s education (p=0.001. Multivariate analysis showed that ECC can be explained by these variables: age, mother’s education, the way to deliver and frequency of breast milk complements/replacement of consumtions, child’s brushing habit, plaque pH, and salivary buffer capacity. Resulting determination coefficient 32.1%. There is no significant correlation between breastfeeding and the level of Early Childhood Caries (ECC. The role of protective qualities of breastfeeding are not shown because of bias in obtaining data influence the incidence of caries.

  2. Validating An Analytic Completeness Model for Kepler Target Stars Based on Flux-level Transit Injection Experiments

    Science.gov (United States)

    Catanzarite, Joseph; Burke, Christopher J.; Li, Jie; Seader, Shawn; Haas, Michael R.; Batalha, Natalie; Henze, Christopher; Christiansen, Jessie; Kepler Project, NASA Advanced Supercomputing Division

    2016-06-01

    The Kepler Mission is developing an Analytic Completeness Model (ACM) to estimate detection completeness contours as a function of exoplanet radius and period for each target star. Accurate completeness contours are necessary for robust estimation of exoplanet occurrence rates.The main components of the ACM for a target star are: detection efficiency as a function of SNR, the window function (WF) and the one-sigma depth function (OSDF). (Ref. Burke et al. 2015). The WF captures the falloff in transit detection probability at long periods that is determined by the observation window (the duration over which the target star has been observed). The OSDF is the transit depth (in parts per million) that yields SNR of unity for the full transit train. It is a function of period, and accounts for the time-varying properties of the noise and for missing or deweighted data.We are performing flux-level transit injection (FLTI) experiments on selected Kepler target stars with the goal of refining and validating the ACM. “Flux-level” injection machinery inserts exoplanet transit signatures directly into the flux time series, as opposed to “pixel-level” injection, which inserts transit signatures into the individual pixels using the pixel response function. See Jie Li's poster: ID #2493668, "Flux-level transit injection experiments with the NASA Pleiades Supercomputer" for details, including performance statistics.Since FLTI is affordable for only a small subset of the Kepler targets, the ACM is designed to apply to most Kepler target stars. We validate this model using “deep” FLTI experiments, with ~500,000 injection realizations on each of a small number of targets and “shallow” FLTI experiments with ~2000 injection realizations on each of many targets. From the results of these experiments, we identify anomalous targets, model their behavior and refine the ACM accordingly.In this presentation, we discuss progress in validating and refining the ACM, and we

  3. Thermionic plasma injection for the Lockheed Martin T4 Compact Fusion Reactor experiment

    Science.gov (United States)

    Heinrich, Jonathon

    2015-11-01

    Lockheed Martin's Compact Fusion Reactor (CFR) concept relies on diamagnetic confinement in a magnetically encapsulated linear ring cusp geometry. Plasma injection into cusp field configurations requires careful deliberation. Previous work has shown that axial injection via a plasma gun is capable of achieving high-beta conditions in cusp configurations. We present a pulsed, high power thermionic plasma source and the associated magnetic field topology for plasma injection into the caulked-cusp magnetic field. The resulting plasma fueling and cross-field diffusion is discussed.

  4. Pitch angle scattering by triggered emissions from the Siple Station wave injection experiment

    Science.gov (United States)

    Harid, V.; Golkowski, M.; Bell, T. F.; Cohen, M.; Inan, U. S.

    2012-12-01

    Nonlinear amplification of whistler mode waves in the Earth's magnetosphere , due to gyroresonance with energetic electrons, also known as the phenomena of VLF triggered emissions, has been investigated extensively with analytical formulations, experimental observations and computer simulations. However, the pitch angle scattering of typical triggered emission waveforms has not been specifically considered. Most authors consider particle scattering either in the presence of a monochromatic constant amplitude wave or a broadband incoherent but time-frequency homogenous emission. Although investigation of these two limiting cases has provided valuable insight into radiation belt dynamics, a large class of waves including triggered emissions and chorus do not fall under either of the two descriptions. The inherent symmetry of a constant amplitude monochromatic wave around the equator results in non-cumulative pitch angle change for a large population of electrons. Wave amplification generated during linear and nonlinear growth result in wave gradients that can have a more significant effect on particle pitch angle and energy. In addition, coherent frequency changing signals are capable of shifting the cyclotron resonance condition and significantly perturbing particle trajectories from their adiabatic motion. The wave-injection experiment at Siple Station, Antarctica was designed to study wave growth and triggering processes in the magnetosphere. Amplified signals from Siple Station often show both wave gradients as well advances in phase and frequency. Using a numerical test-particle simulation, we model the effect of typical Siple Station signals on pitch angle scattering and particle precipitation. Results show that triggered emission type wave forms are more efficient in producing large pitch angle changes in resonant particles.

  5. Ultrasound-guided injection for the biceps brachii tendinitis: results and experience.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Lause, Gregory E

    2011-05-01

    The purpose of this study was to identify the results of ultrasound-guided injection of corticosteroid for biceps brachii tendinitis. In this randomized and prospective study, we evaluated 45 patients who were treated by free-hand injection without ultrasound guidance (group A) and 53 patients who were treated by ultrasound-guided injection (group B). The mean age was 47 y (range, 28 to 72). The average follow-up was 33 weeks (range, 24 to 56). The visual analog scale score decreased from 7.1 ± 2.3 before injection to 4.2 ± 3.1 at follow-up in group A and from 6.9 ± 2.6 to 2.1 ± 1.9 in group B (p biceps brachii tendinitis.

  6. Experience of drilling wells using pump-compressor unit to inject aerated fluid

    Energy Technology Data Exchange (ETDEWEB)

    Oleynik, S.P.; Beley, I.V.; Lopatin, Yu.S.; Pytel, S.P.; Vasilak, I.I.; Yushkevich, V.I.

    1979-01-01

    Results are described from drilling wells with flushing by highly aerated clay fluid with the help of a UNGA unit which includes pumps and compressors of the drilling unit UBSh-1 which permits injection of an aerated mixture under pressures considerably exceeding the pressure of its formation. Qualitative and technical-economic advantages of drilling with flushing by aerated solutions with the use of a unit for injecting gas-liquid agents are presented.

  7. Direct condensation and entrainment steam experiments at the Topflow-Denise facility

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, Tobias [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Inst. of Fluid Dynamics

    2015-10-15

    In a hypothetical Small Break Loss of Coolant Accident (SB-LOCA) in a Pressurized Water Reactor (PWR), the Reactor Pressure Vessel wall (RPV) may be exposed to thermal stress, since the Emergency Core Cooling System (ECCS) injects cold water. The loads on the primary loop and RPV walls are determined by mixing processes with the surrounding hot water and by the condensation of steam on the surface. For the development and validation of CFD-models, experiments have to meet a high standard of reproducibility, measurement certainty and temporal and local resolution. The pressure tank technology of the TOPFLOW facility allows conducting such experiments at reasonable effort.

  8. MICROORGANISMS FOUND IN SECONDARY CATARACT MATERIAL OF ECCE PATIENTS, A STUDY WITH SEM AND TEM

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1993-01-01

    Globular secondary cataract material, removed from 24 patients with ECCE after ophthalmic cleaning of the anterior capsule, were investigated with SEM and TEM. Besides spherical, somewhat oval shaped bodies of various shape and size comparable with those found in cataractous lenses, (an)aerobic

  9. Zirconia crowns--an esthetic and resistant restorative alternative for ECC affected primary teeth.

    Science.gov (United States)

    Planells del Pozo, P; Fuks, A B

    2014-01-01

    The present report discusses briefly the problem of ECC in very young children and the recommended approaches for prevention and treatment. The esthetic restoration of the maxillary incisors with Zirconia Nu Smile crowns is described. It is also stressed that the luxation injury two months after placement did not damage the appearance nor the stability of the crowns.

  10. Complete genome sequences of Escherichia coli strains 1303 and ECC-1470 isolated from bovine mastitis

    NARCIS (Netherlands)

    Leimbach, Andreas; Poehlein, Anja; Witten, Anika; Scheutz, Flemming; Schukken, Ynte; Daniel, Rolf; Dobrindt, Ulrich

    2016-01-01

    Escherichia coli is the leading causative agent of acute bovine mastitis. Here, we report the complete genome sequence of E. coli O70:H32 strain 1303, isolated from an acute case of bovine mastitis, and E. coli Ont:Hnt strain ECC-1470, isolated from a persistent infection.

  11. INJECTING DRUG USERS’ EXPERIENCES OF POLICING PRACTICES IN TWO MEXICAN-U.S. BORDER CITIES: PUBLIC HEALTH PERSPECTIVES

    Science.gov (United States)

    Miller, Cari L.; Firestone, Michelle; Ramos, Rebeca; Burris, Scott; Ramos, Maria Elena; Case, Patricia; Brouwer, Kimberly C.; Fraga, Miguel Angel; Strathdee, Steffanie A.

    2008-01-01

    Background Previous research has identified the impact of law enforcement practices on the behaviors and health of injection drug users (IDUs). We undertook a qualitative study of IDUs’ experiences of policing practices in two Mexican cities on the U.S. border. Methods In 2004, two teams of Mexican interviewers conducted in-depth interviews with IDUs residing in Tijuana and Ciudad Juarez (Cd. Juarez), Mexico who had injected drugs at least once in the prior month. Topics included types of drug used, injection settings, access to sterile needles and experiences with police. Field notes and transcribed interviews were analyzed to identify emergent themes. Results Among the 43 participants, most reported that it is common for IDUs to be arrested and detained for 36 hours for carrying sterile or used syringes. Most reported that they or someone they knew had been beaten by police. Interviews suggested 5 key themes relating to police influence on the risk environment: 1) impact of policing practices on accessibility of sterile syringes, 2) influence of police on choice of places to inject drugs (e.g., shooting galleries), 3) police violence, 4) police corruption, and 5) perceived changes in policing practices. Conclusion Findings suggest that some behavior of police officers in Tijuana and Cd. Juarez is inconsistent with legal norms and may be negatively influencing the risk of acquiring blood-borne infections among IDUs. Implementing a comprehensive and successful HIV prevention program among IDUs requires interventions to influence the knowledge, attitudes and practices of law enforcement officers. PMID:17997089

  12. Candida albicans Carriage in Children with Severe Early Childhood Caries (S-ECC) and Maternal Relatedness

    Science.gov (United States)

    Xiao, Jin; Moon, Yonghwi; Li, Lihua; Rustchenko, Elena; Wakabayashi, Hironao; Zhao, Xiaoyi; Feng, Changyong; Gill, Steven R.; McLaren, Sean; Malmstrom, Hans; Ren, Yanfang; Quivey, Robert

    2016-01-01

    Introduction Candida albicans has been detected together with Streptococcus mutans in high numbers in plaque-biofilm from children with early childhood caries (ECC). The goal of this study was to examine the C. albicans carriage in children with severe early childhood caries (S-ECC) and the maternal relatedness. Methods Subjects in this pilot cross-sectional study were recruited based on a convenient sample. DMFT(S)/dmft(s) caries and plaque scores were assessed during a comprehensive oral exam. Social-demographic and related background information was collected through a questionnaire. Saliva and plaque sample from all children and mother subjects were collected. C. albicans were isolated by BBL™ CHROMagar™ and also identified using germ tube test. S. mutans was isolated using Mitis Salivarius with Bacitracin selective medium and identified by colony morphology. Genetic relatedness was examined using restriction endonuclease analysis of the C. albicans genome using BssHII (REAG-B). Multilocus sequence typing was used to examine the clustering information of isolated C. albicans. Spot assay was performed to examine the C. albicans Caspofungin susceptibility between S-ECC children and their mothers. All statistical analyses (power analysis for sample size, Spearman’s correlation coefficient and multiple regression analyses) were implemented with SAS 9.4 Results A total of 18 S-ECC child-mother pairs and 17 caries free child-mother pairs were enrolled in the study. Results indicated high C. albicans carriage rate in the oral cavity (saliva and plaque) of both S-ECC children and their mothers (>80%). Spearman’s correlation coefficient also indicated a significant correlation between salivary and plaque C. albicans and S. mutans carriage (p60% of them demonstrated identical C. albicans REAG-B pattern. C. albicans isolated from >65% of child-mother pairs demonstrated similar susceptibility to caspofungin in spot assay, while no caspofungin resistant strains were

  13. Investigation of oil injection into brine for the Strategic Petroleum Reserve : hydrodynamics and mixing experiments with SPR liquids.

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, Jaime N.; Cote, Raymond O.; Torczynski, John Robert; O' Hern, Timothy John

    2004-05-01

    An experimental program was conducted to study a proposed approach for oil reintroduction in the Strategic Petroleum Reserve (SPR). The goal was to assess whether useful oil is rendered unusable through formation of a stable oil-brine emulsion during reintroduction of degassed oil into the brine layer in storage caverns. An earlier report (O'Hern et al., 2003) documented the first stage of the program, in which simulant liquids were used to characterize the buoyant plume that is produced when a jet of crude oil is injected downward into brine. This report documents the final two test series. In the first, the plume hydrodynamics experiments were completed using SPR oil, brine, and sludge. In the second, oil reinjection into brine was run for approximately 6 hours, and sampling of oil, sludge, and brine was performed over the next 3 months so that the long-term effects of oil-sludge mixing could be assessed. For both series, the experiment consisted of a large transparent vessel that is a scale model of the proposed oil-injection process at the SPR. For the plume hydrodynamics experiments, an oil layer was floated on top of a brine layer in the first test series and on top of a sludge layer residing above the brine in the second test series. The oil was injected downward through a tube into the brine at a prescribed depth below the oil-brine or sludge-brine interface. Flow rates were determined by scaling to match the ratio of buoyancy to momentum between the experiment and the SPR. Initially, the momentum of the flow produces a downward jet of oil below the tube end. Subsequently, the oil breaks up into droplets due to shear forces, buoyancy dominates the flow, and a plume of oil droplets rises to the interface. The interface was deflected upward by the impinging oil-brine plume. Videos of this flow were recorded for scaled flow rates that bracket the equivalent pumping rates in an SPR cavern during injection of degassed oil. Image-processing analyses were

  14. Preparation and evaluation of {sup 68}Ga-ECC as a PET renal imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro [Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Geramifar, Patham; Beiki, Davood [Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-09-15

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop {sup 68}Ga-ethylenecysteamine cysteine ({sup 68}Ga-ECC). Ga-ECC was prepared using generator-based {sup 68}GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). {sup 68}Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV{sub max} ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous {sup 99m}Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time.

  15. Ramucirumab Injection

    Science.gov (United States)

    ... dose of ramucirumab injection. Tell your doctor or nurse if you experience any of the following while you receive ramucirumab: uncontrollable shaking of a part of the body; back pain or spasms; chest pain and tightness; chills; flushing; ...

  16. Assessment of nitrification potential in ground water using short term, single-well injection experiments.

    Science.gov (United States)

    Smith, R L; Baumgartner, L K; Miller, D N; Repert, D A; Böhlke, J K

    2006-01-01

    Nitrification was measured within a sand and gravel aquifer on Cape Cod, MA, using a series of single-well injection tests. The aquifer contained a wastewater-derived contaminant plume, the core of which was anoxic and contained ammonium. The study was conducted near the downgradient end of the ammonium zone, which was characterized by inversely trending vertical gradients of oxygen (270 to 0 microM) and ammonium (19 to 625 microM) and appeared to be a potentially active zone for nitrification. The tests were conducted by injecting a tracer solution (ambient ground water + added constituents) into selected locations within the gradients using multilevel samplers. After injection, the tracers moved by natural ground water flow and were sampled with time from the injection port. Rates of nitrification were determined from changes in nitrate and nitrite concentration relative to bromide. Initial tests were conducted with (15)N-enriched ammonium; subsequent tests examined the effect of adding ammonium, nitrite, or oxygen above background concentrations and of adding difluoromethane, a nitrification inhibitor. In situ net nitrate production exceeded net nitrite production by 3- to 6- fold and production rates of both decreased in the presence of difluoromethane. Nitrification rates were 0.02-0.28 mumol (L aquifer)(-1) h(-1) with in situ oxygen concentrations and up to 0.81 mumol (L aquifer)(-1) h(-1) with non-limiting substrate concentrations. Geochemical considerations indicate that the rates derived from single-well injection tests yielded overestimates of in situ rates, possibly because the injections promoted small-scale mixing within a transport-limited reaction zone. Nonetheless, these tests were useful for characterizing ground water nitrification in situ and for comparing potential rates of activity when the tracer cloud included non-limiting ammonium and oxygen concentrations.

  17. New Experiences With Steam Injection From The MÜhlacker Field Site

    Science.gov (United States)

    Theurer, T.; Koschitzky, H.-P.; Färber, A.

    A thermally enhanced remediation scheme employing steam injection has been used at a former hazardous waste disposal site near the City of Mühlacker, Germany, to remove chlorinated solvents. Finding SVE (soil vapour extraction) to be ineffective in the unsaturated soil zone, a pilot-scale project was initiated in 1999 to employ steam injection in the highly contaminated unsaturated low permeable zone 7-15 meters be- low ground surface, limited on top and bottom by very low permeable layers. After completion of the project in September 2001, approximately 2.8 tons of chlorinated hydrocarbons had been removed from the 2500 m3 target area. This project served as a pilot site in the State of Baden-Württemberg EPA (Landesanstalt für Umweltschutz, LfU) site cleanup program, which was funded through the State's "Kommunaler Alt- lastenfonds". Detailed evaluation of SVE technology had indicated that the low permeability in this soil served as a limiting factor for "cold" SVE. As a result, alternative technologies were considered and thermally enhanced SVE by steam injection was selected in 1998 to address the unsaturated zone contaminants. A 20-meter diameter, egg-shaped test- ing area was constructed at the site for pilot-scale demonstration of the steam injection process. The testing area comprised one central injection well surrounded by six ex- traction wells that could be used simultaneously for vapor and liquid extraction. Ten monitoring lances with a total of 100 temperature sensors measured subsurface tem- peratures through the soil horizon. Using a gas-fired 100 kW generator, steam was injected at a rate of up to 100 kg/hour and a pressure of up to 2.5 bars. After ten months of steam injection, nearly complete heating of the target zone had been achieved. of the 2800 kg of TCE removed, approximately 95% was extracted in the gaseous phase and the remaining part as solute in condensed water from the capillary barrier on bottom of the soil horizon. This condensed

  18. Single well push-pull CO2 injection experiment for evaluating in-situ residual trapping at Heletz, Israel

    Science.gov (United States)

    Niemi, Auli; Bensabat, Jacob; Fagerlund, Fritjof; Ronen, Rona; Goren, Yoni; Perez, Lily; Tsarfis, Igal; Joodaki, Saba; Yang, Zhibing; Liang, Tian; Sauter, Martin; Hassan, Jawad; Gouze, Philippe; Rasmusson, Kristina

    2017-04-01

    The Heletz sands is a depleted oil reservoir at 1.6 km depth with saline water at its edges. In the saline part of the reservoir a CO2 injection experiment site has been developed for the purpose of scientifically motivated injection experiments, especially in the context of EU FP7 projects MUSTANG and TRUST. This presentation describes the single-well CO2 injection experiment carried out in September 2016, with the objective of determining field scale values of key CO2 trapping mechanisms, the residual and dissolution trapping. The sequence consisted in creating a residually trapped CO2 zone as well as reference hydraulic and heater tests prior and after the establishment of the zone, in order to determine the in-situ residual trapping. Monitoring included down-hole pressure and temperature measurement, distributed temperature sensing along the well via an optical fiber (DTS), U-tube sampling and tracers. We here present the experimental sequence, the monitoring and sampling system, the key results as well as the first interpretations.

  19. Assessment of electrical conductivity as a surrogate measurement for water samples in a tracer injection experiment

    Science.gov (United States)

    The transport behavior of solutes in streams depends on chemical, physical, biological, and hydrodynamic processes. Although it is a very complex system, it is known that this behavior is greatly influenced by surface and subsurface flows. For this reason, tracer injection in the water flows is one ...

  20. Oklahoma experiences largest earthquake during ongoing regional wastewater injection hazard mitigation efforts

    Science.gov (United States)

    Yeck, William; Hayes, Gavin; McNamara, Daniel E.; Rubinstein, Justin L.; Barnhart, William; Earle, Paul; Benz, Harley M.

    2017-01-01

    The 3 September 2016, Mw 5.8 Pawnee earthquake was the largest recorded earthquake in the state of Oklahoma. Seismic and geodetic observations of the Pawnee sequence, including precise hypocenter locations and moment tensor modeling, shows that the Pawnee earthquake occurred on a previously unknown left-lateral strike-slip basement fault that intersects the mapped right-lateral Labette fault zone. The Pawnee earthquake is part of an unprecedented increase in the earthquake rate in Oklahoma that is largely considered the result of the deep injection of waste fluids from oil and gas production. If this is, indeed, the case for the M5.8 Pawnee earthquake, then this would be the largest event to have been induced by fluid injection. Since 2015, Oklahoma has undergone wide-scale mitigation efforts primarily aimed at reducing injection volumes. Thus far in 2016, the rate of M3 and greater earthquakes has decreased as compared to 2015, while the cumulative moment—or energy released from earthquakes—has increased. This highlights the difficulty in earthquake hazard mitigation efforts given the poorly understood long-term diffusive effects of wastewater injection and their connection to seismicity.

  1. Micro Engineering: Experiments conducted on the use of polymeric materials in micro injection moulding

    DEFF Research Database (Denmark)

    Griffiths, Christian; Tosello, Guido; Nestler, Joerg

    2008-01-01

    To advance micro injection moulding it is necessary to study systematically the factors affecting process and tooling reliability. This paper reviews the main findings of Cardiff Universities 4M and SEMOFS research in this field. In particular, the factors affecting the manufacturability of micro...

  2. Ecce Homo: Science and Society Need Anthropological Collections.

    Science.gov (United States)

    Sholts, Sabrina B; Bell, Joshua A; Rick, Torben C

    2016-08-01

    Scientific collections are crucial to understanding the biological and cultural diversity of the Earth. Anthropological collections document the human experience and the interactions between people, ecosystems, and organisms. Unfortunately, anthropological collections are often poorly known by the public and face a variety of threats to their permanent care and conservation.

  3. Road Maintenance Experience Using Polyurethane (PU) Foam Injection System and Geocrete Soil Stabilization as Ground Rehabilitation

    Science.gov (United States)

    Fakhar, A. M. M.; Asmaniza, A.

    2016-07-01

    There are many types of ground rehabilation and improvement that can be consider and implement in engineering construction works for soil improvement in order to prevent road profile deformation in later stage. However, when comes to road maintenance especially on operated expressways, not all method can be apply directly as it must comply to opreation's working window and lane closure basis. Key factors that considering ideal proposal for ground rehabilitation are time, cost, quality and most importantly practicality. It should provide long lifespan structure in order to reduce continuous cycle of maintenance. Thus, this paper will present two approaches for ground rehabilitation, namely Polyurethane (PU) Foam Injection System and Geocrete Soil Stabilization. The first approach is an injection system which consists two-parts chemical grout of Isocynate and Polyol when mixed together within soil structure through injection will polymerized with volume expansion. The strong expansion of grouting causes significant compression and compacting of the surrounding soil and subsequently improve ground properties and uplift sunken structure. The later is a cold in-place recyclying whereby mixture process that combines in-situ soil materials, cement, white powder (alkaline) additive and water to produce hard yet flexible and durable ground layer that act as solid foundation with improved bearing capacity. The improvement of the mechanical behaviour of soil through these two systems is investigated by an extensive testing programme which includes in-situ and laboratory test in determining properties such as strength, stiffness, compressibility, bearing capacity, differential settlement and etc.

  4. Electron Temperature Evolution During Local Helicity Injection on the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Barr, J. L.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Perry, J. M.; Reusch, J. A.; Rodriguez Sanchez, C.

    2016-10-01

    Understanding the electron temperature (Te) evolution during local helicity injection (LHI) is critical for scaling up this non-solenoidal startup technique to MA-class devices. The first comprehensive Te measurements during LHI reveal centrally-peaked profiles with Te > 100 eV for plasma current Ip > 120 kA, toroidal field 0.15 T, and electron density ne 1019 m-3. Te rises and is sustained from just after magnetic relaxation through the plasma decoupling from edge-localized injectors. Results are presented for two injector edge locations: outboard midplane and inboard divertor. Outboard midplane injection couples LHI with inductive drive from poloidal field ramps and radial compression during inward plasma growth. Comparisons of Te at different LHI-to-inductive drive ratios show some profile flattening for higher LHI drive fraction. The latter, constant-shape discharges were necessarily lower performance, with Ip 50 kA and reduced Te , max. Inboard divertor injection achieves higher Ip using minimal inductive drive and thus isolates effects of LHI drive on Te. Initial results in this configuration show Te rising rapidly at the injector location as the discharge grows, settling to a roughly flat profile 100 eV. Thus far, both scenarios provide relatively stable discharges with moderate ne and high-Te, suitable for coupling to auxiliary current drive. Detailed studies of confinement dynamics and discharge optimization are planned for the near future. Work supported by US DOE Grant DE-FG02-96ER54375.

  5. Modifying the ECC-based grouping-proof RFID system to increase inpatient medication safety.

    Science.gov (United States)

    Ko, Wen-Tsai; Chiou, Shin-Yan; Lu, Erl-Huei; Chang, Henry Ker-Chang

    2014-09-01

    RFID technology is increasingly used in applications that require tracking, identification, and authentication. It attaches RFID-readable tags to objects for identification and execution of specific RFID-enabled applications. Recently, research has focused on the use of grouping-proofs for preserving privacy in RFID applications, wherein a proof of two or more tags must be simultaneously scanned. In 2010, a privacy-preserving grouping proof protocol for RFID based on ECC in public-key cryptosystem was proposed but was shown to be vulnerable to tracking attacks. A proposed enhancement protocol was also shown to have defects which prevented proper execution. In 2012, Lin et al. proposed a more efficient RFID ECC-based grouping proof protocol to promote inpatient medication safety. However, we found this protocol is also vulnerable to tracking and impersonation attacks. We then propose a secure privacy-preserving RFID grouping proof protocol for inpatient medication safety and demonstrate its resistance to such attacks.

  6. Nd:YAG laser removal of pupillary membranes developed after ECCE with PC-IOL implantation.

    Science.gov (United States)

    Kozobolis, V P; Pallikaris, I G; Tsambarlakis, I G; Vlachonikolis, I G

    1997-12-01

    To define the frequency of development of pupillary membranes after ECCE with PC-IOL implantation, and to remove the pupillary membranes using the Nd:YAG laser. From 400 patients who had undergone ECCE and were free from local or systemic illness affecting the blood-ocular barrier, 20 eyes developed pupillary membranes Nd:YAG laser was used to remove these pupillary membranes. The frequency of pupillary membranes was found to be 5% (9.8% in pex eyes and 3.3% to the non-pex eyes). Visual acuity improved in 17 eyes by 2 to 5 Snellen lines. No serious complications were observed, endothelium inclusive. Pseudoexfoliation might play a significant role in the development of postoperative pupillary membranes which could be successfully treated with the use of Nd:YAG laser. The safety of the procedure has to be evaluated in relation to the corneal endothelium damage in long-term.

  7. Prosthetic Oral Rehabilitation of a Child With S-ECC: A Case Report with Histopathologic Analysis.

    Science.gov (United States)

    Tannure, P N; Moraes, G G; Borba, McU; Abrahão, A; Andrade, Mtrc; Fidalgo, Tks

    2015-01-01

    The aim of this case report is to describe the treatment planning of a young child with severe early childhood caries (S-ECC) as well as the prosthetic rehabilitation technique. A 3-year-old female child was referred to the pediatric dentistry clinic with the chief complaint of tooth pain, difficulty in eating and recurrent hospitalizations caused by dental infections. The mother reported intermittent episodes of fever and recurrent swelling of child's face. The girl presented angular cheilitis and was referred to a dietitian. The treatment plain consisted on a behavior changes in oral hygiene habits, exodontias of all primary teeth and oral rehabilitation with a prosthesis. The extracted teeth with periapical lesions were submitted to histopathologic analysis (hematoxilin and eosin staining) and revealed an inflammatory infiltrate. The aesthetic requirement of children with S-ECC has been a challenge to pediatric dentists. In the present case, the oral rehabilitation provided for the children better aesthetic, nutrition, phonation, and functional conditions.

  8. Lithium pellet injection experiments on the Alcator C-Mod tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Garnier, D.T.

    1996-06-01

    A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient ({ell}{sub p} {le} a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li{sup +} emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = {infinity} and the n = 1 marginal stability limits.

  9. TRACE code validation for BWR spray cooling injection based on GOTA facility experiments

    Energy Technology Data Exchange (ETDEWEB)

    Racca, S. [San Piero a Grado Nuclear Research Group (GRNSPG), Pisa (Italy); Kozlowski, T. [Royal Inst. of Tech., Stockholm (Sweden)

    2011-07-01

    Best estimate codes have been used in the past thirty years for the design, licensing and safety of NPP. Nevertheless, large efforts are necessary for the qualification and the assessment of such codes. The aim of this work is to study the main phenomena involved in the emergency spray cooling injection in a Swedish designed BWR. For this purpose, data from the Swedish separate effect test facility GOTA have been simulated using TRACE version 5.0 Patch 2. Furthermore, uncertainty calculations have been performed with the propagation of input errors method and the identification of the input parameters that mostly influence the peak cladding temperature has been performed. (author)

  10. Comparison of data on Early Childhood Caries (ECC) with previous data for Baby Bottle Tooth Decay (BBTD) in an Italian kindergarten population.

    Science.gov (United States)

    Ferro, R; Besostri, A; Meneghetti, B; Beghetto, M

    2004-06-01

    This was to assess the prevalence of Early Childhood Caries (ECC) among preschool children attending nursery schools and to compare the results with those of a previous survey where the investigators used the term and diagnosis for Baby Bottle Tooth Decay (BBTD) syndrome. A cross-sectional survey of 1006 children aged 1-6 years was carried out. WHO recommendations for oral health surveys were used for caries diagnosis (non cavitated lesions were excluded). In addition, a comparison was made for prevalence of ECC between immigrant and native born children. Data were compared for ECC in the present survey with BBTD data in a previous study (1994) in the same area with a sample of 401 children aged 4 years. All examinations were by one examiner (Cohen's Kappa=0.96). Of the 1006 children originally selected 52 children aged more than 71 months were excluded according to published ECC definition and diagnostic criteria. The overall sample was 29 children aged <36 months; 271 aged 3 years; 364 aged 4 years and 290 aged 5 years. ECC was diagnosed in 19.7% of the overall sample. The prevalence of ECC (and S-ECC) were respectively by age: <36 months S-ECC=17.2%; at 3 years: 13.28% (6.64%); at 4 years: 18.95% (9.34%); at 5 years: 26.9% (12.75%). In the native born children (916) the ECC was 18.34%, while in immigrants (38) it was 52.63% (p<0.001). In 1994 the prevalence of BBTD syndrome was 11.9% and in the present study 6.5%. The ECC prevalence, as, ECC and severe (S-ECC),increased with age. In immigrant children ECC was 3 times (S-ECC 6 times) more frequent than in native born. Using the BBTD diagnosis the prevalence had dropped from 11.9% in 1994 to 6.5% in the present survey.

  11. A Secure-Enhanced Data Aggregation Based on ECC in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Qiang Zhou

    2014-04-01

    Full Text Available Data aggregation is an important technique for reducing the energy consumption of sensor nodes in wireless sensor networks (WSNs. However, compromised aggregators may forge false values as the aggregated results of their child nodes in order to conduct stealthy attacks or steal other nodes’ privacy. This paper proposes a Secure-Enhanced Data Aggregation based on Elliptic Curve Cryptography (SEDA-ECC. The design of SEDA-ECC is based on the principles of privacy homomorphic encryption (PH and divide-and-conquer. An aggregation tree disjoint method is first adopted to divide the tree into three subtrees of similar sizes, and a PH-based aggregation is performed in each subtree to generate an aggregated subtree result. Then the forged result can be identified by the base station (BS by comparing the aggregated count value. Finally, the aggregated result can be calculated by the BS according to the remaining results that have not been forged. Extensive analysis and simulations show that SEDA-ECC can achieve the highest security level on the aggregated result with appropriate energy consumption compared with other asymmetric schemes.

  12. Transient changes in shallow groundwater chemistry during the MSU ZERT CO2 injection experiment

    Science.gov (United States)

    Apps, J.A.; Zheng, Lingyun; Spycher, N.; Birkholzer, J.T.; Kharaka, Y.; Thordsen, J.; Kakouros, E.; Trautz, R.

    2011-01-01

    Food-grade CO2 was injected into a shallow aquifer through a perforated pipe placed horizontally 1-2 m below the water table at the Montana State University Zero Emission Research and Technology (MSU-ZERT) field site at Bozeman, Montana. The possible impact of elevated CO2 levels on groundwater quality was investigated by analyzing 80 water samples taken before, during, and following CO2 injection. Field determinations and laboratory analyses showed rapid and systematic changes in pH, alkalinity, and conductance, as well as increases in the aqueous concentrations of trace element species. The geochemical data were first evaluated using principal component analysis (PCA) in order to identify correlations between aqueous species. The PCA findings were then used in formulating a geochemical model to simulate the processes likely to be responsible for the observed increases in the concentrations of dissolved constituents. Modeling was conducted taking into account aqueous and surface complexation, cation exchange, and mineral precipitation and dissolution. Reasonable matches between measured data and model results suggest that: (1) CO2 dissolution in the groundwater causes calcite to dissolve. (2) Observed increases in the concentration of dissolved trace metals result likely from Ca+2-driven ion exchange with clays (smectites) and sorption/desorption reactions likely involving Fe (hydr)oxides. (3) Bicarbonate from CO2 dissolution appears to compete for sorption with anionic species such as HAsO4-2, potentially increasing dissolved As levels in groundwater. ?? 2011 Published by Elsevier Ltd.

  13. Suppression of Alfvén Modes on the National Spherical Torus Experiment Upgrade with Outboard Beam Injection

    Science.gov (United States)

    Fredrickson, E. D.; Belova, E. V.; Battaglia, D. J.; Bell, R. E.; Crocker, N. A.; Darrow, D. S.; Diallo, A.; Gerhardt, S. P.; Gorelenkov, N. N.; LeBlanc, B. P.; Podestà, M.; NSTX-U Team

    2017-06-01

    In this Letter we present data from experiments on the National Spherical Torus Experiment Upgrade, where it is shown for the first time that small amounts of high pitch-angle beam ions can strongly suppress the counterpropagating global Alfvén eigenmodes (GAE). GAE have been implicated in the redistribution of fast ions and modification of the electron power balance in previous experiments on NSTX. The ability to predict the stability of Alfvén modes, and developing methods to control them, is important for fusion reactors like the International Tokamak Experimental Reactor, which are heated by a large population of nonthermal, super-Alfvénic ions consisting of fusion generated α 's and beam ions injected for current profile control. We present a qualitative interpretation of these observations using an analytic model of the Doppler-shifted ion-cyclotron resonance drive responsible for GAE instability which has an important dependence on k⊥ρL . A quantitative analysis of this data with the hym stability code predicts both the frequencies and instability of the GAE prior to, and suppression of the GAE after the injection of high pitch-angle beam ions.

  14. Convento del Santo Ecce-Homo síntesis histórica y esbozo analítico

    Directory of Open Access Journals (Sweden)

    Alberto Corradine

    2012-08-01

    Full Text Available Convento del Santo ECCE-HOMO, Síntesis histórica y esbozo-analítico/ Alberto Corradine. No. 6-7, 1971-1972; p. 57-68. El autor describe y analiza el estilo arquitectónico del ECCE-HOMO señalando especialmente la influencia del estilo mudejar venido de España en el siglo XVII. 

  15. Convento del santo ecce-homo síntesis histórica y esbozo analítico

    OpenAIRE

    Alberto Corradine

    2012-01-01

    Convento del Santo ECCE-HOMO, Síntesis histórica y esbozo-analítico/ Alberto Corradine. No. 6-7, 1971-1972; p. 57-68. El autor describe y analiza el estilo arquitectónico del ECCE-HOMO señalando especialmente la influencia del estilo mudejar venido de España en el siglo XVII. 

  16. Experience of direct percutaneous sac injection in type II endoleak using cone beam computed tomography.

    Science.gov (United States)

    Park, Yoong-Seok; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Dong-Ik

    2015-04-01

    Cone beam CT, usually used in dental area, could easily obtain 3-dimensional images using cone beam shaped ionized radiation. Cone beam CT is very useful for direct percutaneous sac injection (DPSI) which needs very precise measurement to avoid puncture of inferior vena cava or vessel around sac or stent graft. Here we describe two cases of DPSI using cone beam CT. In case 1, a 79-year-old male had widening of preexisted type II endoleak after endovascular aneurysm repair (EVAR). However, transarterial embolization failed due to tortuous collateral branches of lumbar arteries. In case 2, a 72-year-old female had symptomatic sac enlargement by type II endoleak after EVAR. However, there was no route to approach the lumbar arteries. Therefore, we performed DPSI assisted by cone beam CT in cases 1, 2. Six-month CT follow-up revealed no sign of sac enlargement by type II endoleak.

  17. EXPERIENCE OF INTRAVENOUS INJECTION OF NORMAL HUMAN IMMUNOGLOBULIN IN A PATIENT WITH KAWASAKI SYNDROME

    Directory of Open Access Journals (Sweden)

    T. V. Sleptsova

    2014-01-01

    Full Text Available The article presents a case of late diagnosis of cutaneomucosal lymphonodular syndrome (Kawasaki syndrome. The child featured fever, mucosal lesion (conjunctivitis, stomatitis, rash, thick edemas on arms and feet, arthritis and coronaritis. Initial therapy proved ineffective. Pathogenetic therapy, which proved to be rather effective, was prescribed after diagnosis was confirmed. The authors present a case of successful use of normal human immunoglobulin for intravenous injections in the dose of 2 g/kg of body weight per course in combination with acetylsalicylic acid in the dose of 80 mg/kg per day. Body temperature decreased down to subfebrile figures and foot pain attenuated as early as after 1 day of treatment. Fever, rash, stomatitis and conjunctivitis terminated, edemas of limbs and arthritic manifestations attenuated considerably and laboratory parameters of disease activity normalized after 1 week (ESR and CRP. Inflammation of coronary arteries terminated after 3 weeks. No adverse events in the setting of immunoglobulin therapy were observed.  

  18. Initial Thomson Scattering Survey of Local Helicity Injection and Ohmic Plasmas at the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Winz, G. R.

    2014-10-01

    A multipoint Thomson scattering diagnostic has recently been installed on the Pegasus ST. The system utilizes a frequency-doubled Nd:YAG laser (λ0 ~ 532 nm), spectrometers with volume phase holographic gratings, and a gated, intensified CCD camera. It provides measurements of Te and ne at 8 spatial locations for each spectrometer once per discharge. A new multiple aperture and beam dump system has been implemented to mitigate interference from stray light. This system has provided initial measurements in the core region of plasmas initiated by local helicity injection (LHI), as well as conventional Ohmic L- and H-mode discharges. Multi-shot averages of low-density (ne ~ 3 ×1018 m-3) , Ip ~ 0 . 1 MA LHI discharges show central Te ~ 75 eV at the end of the helicity injection phase. Ip ~ 0 . 13 MA Ohmic plasmas at moderate densities (ne ~ 2 ×1019 m-3) have core Te ~ 150 eV in L-mode. Generally, these plasmas do not reach transport equilibrium in the short 25 ms pulse length available. After an L-H transition, strong spectral broadening indicates increasing Te, to values above the range of the present spectrometer system with a high-dispersion VPH grating. Near-term system upgrades will focus on deploying a second spectrometer, with a lower-dispersion grating capable of measuring the 0.1-1.0 keV range. The second spectrometer system will also increase the available number of spatial channels, enabling study of H-mode pedestal structure. Work supported by US DOE Grant DE-FG02-96ER54375.

  19. OPERA experiment

    CERN Document Server

    Komatsu, M

    2003-01-01

    OPERA is an accelerator experiment designed to explore Super- Kamiokande suggested nu//mu arrow left right nu//tau oscillation region in CNGS beam from CERN to LNGS. The key technique in OPERA is modern emulsion read out which applied to CHORUS and DONUT experiments. ECC technique which used in DONUT and OPERA has good modularity to enlarge apparatus for future Neutrino Factory experiments.

  20. EMC3-EIRENE modeling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Lore, J.D., E-mail: lorejd@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Reinke, M.L. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); LaBombard, B. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Lipschultz, B. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Churchill, R.M. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Feng, Y. [Max Planck Institute for Plasma Physics, Greifswald (Germany)

    2015-08-15

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ∼50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modeling, with the simulation yielding a toroidal asymmetry in the heat flow to the outer strike point. Toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.

  1. Geophysical monitoring of near surface CO2 injection at Svelvik - Learnings from the CO2FieldLab experiments.

    Science.gov (United States)

    Querendez, Etor; Romdhane, Anouar; Jordan, Michael; Eliasson, Peder; Grimstad, Alv-Arne

    2014-05-01

    A CO2 migration field laboratory for testing monitoring methods and tools has been established in the glaciofluvial-glaciomarine Holocene deposits of the Svelvik ridge, near Oslo (Norway). At the site, feasibility, sensitivity, acquisition geometry and usefulness of various surface and subsurface monitoring tools are investigated during controlled CO2 injection experiments. In a first stage, a shallow CO2 injection experiment was conducted in September 2011. Approximately 1700 kg of CO2 was injected at 18 m depth below surface in an unconsolidated sand formation. The objectives of this experiment were to (i) detect and, where possible, quantify migrated CO2 concentrations at the surface and very shallow subsurface, (ii) evaluate the sensitivity of the monitoring tools and (iii) study the impact of the vadose zone on observed measurements. Results showed that all deployed monitoring tools (for surface and near-surface gas monitoring, subsurface water monitoring and subsurface geophysical monitoring) where able to detect the presence of CO2 even though the CO2 plume did not migrate vertically as expected in what was thought to be an homogeneous unconsolidated sand structure. The upper part of the site revealed to be more heterogeneous than expected, mainly due to the highly variable lamination and channelling of the morainic sediments and to the presence of pebble and cobble beds sporadically showing throughout the deposits. Building on the learnings from the 18m depth injection experiment, a second experiment is being planned for a deeper injection, at a depth of 65m. Re-processing of the appraisal 2D multi-channel seismic with state-of-the-art processing techniques, like Linear Radon coherent and random noise attenuation and Full Waveform Inversion followed by pre-stack depth migration, corroborate the presence of heterogeneities at the near surface. Based on the re-interpreted seismic sections, a more realistic 3D geomodel, where the complex topography of the site

  2. Preferential heating of light ions during an ionospheric Ar(+) injection experiment

    Science.gov (United States)

    Pollock, C. J.; Chandler, M. O.; Moore, T. E.; Arnoldy, R. L.; Kintner, P. M.; Chesney, S.; Cahill, L. J., Jr.

    1995-01-01

    The Argon Release for Controlled Studies (ARCS) 4 sounding rocket was launched northward into high altitude from Poker Flat Research Range on February 23, 1990. The vehicle crossed geomagnetic field lines containing discrete auroral activity. An instrumented subpayload released 100-eV and 200-eV Ar(+) ion beams sequentially, in a direction largely perpendicular to both the local geomagnetic field and the subpayload spin axis. The instrumented main payload was separated along field lines from the beam emitting subpayload by a distance which increased at a steady rate of approximately 2.4 m/s. Three dimensional mass spectrometric ion observations of ambient H(+) and O(+) ions, obtained on board the main payload, are presented. Main payload electric field observations in the frequency range 0-16 kHz, are also presented. These observations are presented to demonstrate the operation of transverse ion acceleration, which was differential with respect to ion mass, primarily during 100-eV beam operations. The preferential transverse acceleration of ambient H(+) ions, as compared with ambient O(+) ions, during the second, third, fourth, and fifth 100-eV beam operations, is attributed to a resonance among the injected Ar(+) ions, beam-generated lower hybrid waves, and H(+) ions in the tail of the ambient thermal distribution. This work provides experimental support of processes predicted by previously published theory and simulations.

  3. Design of a shock-induced combustion experiment in an axisymmetric configuration with hydrogen injection

    NARCIS (Netherlands)

    Verreault, J.; DeChamplain, A.; Mayer, A.E.H.J.; Veraar, R.G.; Stowe, R.A.; Farinaccio, R.; Harris, P.G.

    2007-01-01

    This work presents a design for a shock-induced combustion experiment using a two-angle cone configuration. Three injector geometries were considered: a cone surface, a dual stage configuration with rectangular gaps (DSRG) and a cylindrical ramp (CR). Four parameters were investigated: the

  4. Design of a shock-induced combustion experiment in an axisymmetric configuration with hydrogen injection

    NARCIS (Netherlands)

    Verreault, J.; DeChamplain, A.; Mayer, A.E.H.J.; Veraar, R.G.; Stowe, R.A.; Farinaccio, R.; Harris, P.G.

    2007-01-01

    This work presents a design for a shock-induced combustion experiment using a two-angle cone configuration. Three injector geometries were considered: a cone surface, a dual stage configuration with rectangular gaps (DSRG) and a cylindrical ramp (CR). Four parameters were investigated: the penetrati

  5. The CSNI/PWG-1 international task group on ECCS reliability

    Energy Technology Data Exchange (ETDEWEB)

    Sandervag, O.; Riekert, T.; Serkiz, A.; Hyvarinen, J.

    1996-03-01

    A steam line loss-of-coolant accident (LOCA) occurred when a safety relief valve inadvertently opened in the Barseback-2 nuclear power plant. The steam jet stripped fibrous insulation from adjacent pipework. Part of that insulation debris was transported to the wetwell pool and clogged the intake strainers for the drywell spray system after about one hour. Although the incident in itself was not very serious, it revealed a weakness in the defense-in-depth concept which under other circumstances could have led to failure of the emergency core cooling system (ECCS) to provide water to the core. Before the Barseback-2 LOCA, international regulators of nuclear power plants and the nuclear power plant industry had considered safety questions related to strainer clogging as resolved. Many European countries had followed the guidance for strainers in pressurized water reactors (PWRs) contained in United States Nuclear Regulatory Commission`s (USNRC) Regulatory Guide 1.82, Water Sources for Long Term Recirculation Cooling Following a Loss-of-Coolant Accident, 1974. However, data obtained from European experimental programs carried out in the late seventies to determine the performance of strainers indicated that this guide was not adequate. In addition, Swedish plant owners had used this guidance to judge performance of emergency core cooling systems (ECCS) in their plants. Analyses at that time had indicated that strainer clogging, if occurring at all, would at least not occur during the first ten hours after a LOCA. Since operation of the ECCS would be needed for a long time, backflushing capabilities and monitors of pressure drop across the strainers were installed in older Swedish BWR plants with small strainer areas. These actions were judged to be adequate compliance with the revised USNRC Regulatory Guide 1.82, Rev. 1, issued in 1985. Safety questions related to strainer clogging were considered to have been resolved until the incident happened in Barseback-2.

  6. Fluorouracil Injection

    Science.gov (United States)

    ... of a doctor who is experienced in giving chemotherapy medications for cancer. Treatment with fluorouracil injection may cause serious side effects. ... this medication.If you experience a serious side effect, you or your doctor ... (FDA) MedWatch Adverse Event Reporting program online (http://www.fda.gov/ ...

  7. Paliperidone Injection

    Science.gov (United States)

    ... the body slow movements or shuffling walk painful erection of the penis that lasts for hours cough, chills and/or other signs of infection Paliperidone injection may cause other side effects. Call your doctor if you have any unusual problems while taking this medication.If you experience a ...

  8. Ziprasidone Injection

    Science.gov (United States)

    ... stiffness falling confusion sweating loss of consciousness painful erection of the penis that lasts for hours Ziprasidone injection may cause other side effects. Call your doctor if you have any unusual problems while receiving this medication.If you experience a ...

  9. Risperidone Injection

    Science.gov (United States)

    ... control slow movements or shuffling walk falling painful erection of the penis that lasts for hours Risperidone extended-release injection may cause other side effects. Call your doctor if you have any unusual problems while receiving this medication.If you experience a ...

  10. Predicting Clearance Mechanism in Drug Discovery: Extended Clearance Classification System (ECCS).

    Science.gov (United States)

    Varma, Manthena V; Steyn, Stefanus J; Allerton, Charlotte; El-Kattan, Ayman F

    2015-12-01

    Early prediction of clearance mechanisms allows for the rapid progression of drug discovery and development programs, and facilitates risk assessment of the pharmacokinetic variability associated with drug interactions and pharmacogenomics. Here we propose a scientific framework--Extended Clearance Classification System (ECCS)--which can be used to predict the predominant clearance mechanism (rate-determining process) based on physicochemical properties and passive membrane permeability. Compounds are classified as: Class 1A--metabolism as primary systemic clearance mechanism (high permeability acids/zwitterions with molecular weight (MW) ≤400 Da), Class 1B--transporter-mediated hepatic uptake as primary systemic clearance mechanism (high permeability acids/zwitterions with MW >400 Da), Class 2--metabolism as primary clearance mechanism (high permeability bases/neutrals), Class 3A--renal clearance (low permeability acids/zwitterions with MW ≤400 Da), Class 3B--transporter mediated hepatic uptake or renal clearance (low permeability acids/zwitterions with MW >400 Da), and Class 4--renal clearance (low permeability bases/neutrals). The performance of the ECCS framework was validated using 307 compounds with single clearance mechanism contributing to ≥70% of systemic clearance. The apparent permeability across clonal cell line of Madin - Darby canine kidney cells, selected for low endogenous efflux transporter expression, with a cut-off of 5 × 10(-6) cm/s was used for permeability classification, and the ionization (at pH7) was assigned based on calculated pKa. The proposed scheme correctly predicted the rate-determining clearance mechanism to be either metabolism, hepatic uptake or renal for ~92% of total compounds. We discuss the general characteristics of each ECCS class, as well as compare and contrast the framework with the biopharmaceutics classification system (BCS) and the biopharmaceutics drug disposition classification system (BDDCS

  11. The course of nonproliferative diabetic retinopathy following ECCE with posterior chamber IOL implantation.

    Science.gov (United States)

    Raniel, Y; Teichner, Y; Friedman, Z

    1994-01-01

    A prospective study on the effect of ECCE + IOL implantation on the course of diabetic retinopathy (DR) in 59 eyes showed that in one to three years following surgery, progression of DR, including the development of newly formed one, occurred in 28.8% of the eyes. This was more marked in patient with IDDM (IDDM-46%, NIDDM-24%) as well as in eyes with pre-operative BDR (pre-operative BDR-62.5%, no pre-operative BDR-16.3%). Final visual acuity was better in eyes without pre-operative DR as well as in eyes that did not show progression of the retinopathy.

  12. Microorganisms found in secondary cataract material of ECCE patients, a study with SEM and TEM.

    Science.gov (United States)

    Kalicharan, D; Jongebloed, W L; Los, L I; Worst, J G

    1993-01-01

    Globular secondary cataract material, removed from 24 patients with ECCE after ophthalmic cleaning of the anterior capsule, were investigated with SEM and TEM. Besides spherical, somewhat oval shaped bodies of various shape and size comparable with those found in cataractous lenses, (an)aerobic bacteria and yeast cells were found in approximately 70% of the cases, all of them in eyes without intra-ocular inflammation. Probably these bacteria have been transferred from the conjunctiva during IOL.-implantation and were encapsulated without starting an inflammation.

  13. Post-manufacturing, 17-times acceptable raw bit error rate enhancement, dynamic codeword transition ECC scheme for highly reliable solid-state drives, SSDs

    Science.gov (United States)

    Tanakamaru, Shuhei; Fukuda, Mayumi; Higuchi, Kazuhide; Esumi, Atsushi; Ito, Mitsuyoshi; Li, Kai; Takeuchi, Ken

    2011-04-01

    A dynamic codeword transition ECC scheme is proposed for highly reliable solid-state drives, SSDs. By monitoring the error number or the write/erase cycles, the ECC codeword dynamically increases from 512 Byte (+parity) to 1 KByte, 2 KByte, 4 KByte…32 KByte. The proposed ECC with a larger codeword decreases the failure rate after ECC. As a result, the acceptable raw bit error rate, BER, before ECC is enhanced. Assuming a NAND Flash memory which requires 8-bit correction in 512 Byte codeword ECC, a 17-times higher acceptable raw BER than the conventional fixed 512 Byte codeword ECC is realized for the mobile phone application without an interleaving. For the MP3 player, digital-still camera and high-speed memory card applications with a dual channel interleaving, 15-times higher acceptable raw BER is achieved. Finally, for the SSD application with 8 channel interleaving, 13-times higher acceptable raw BER is realized. Because the ratio of the user data to the parity bits is the same in each ECC codeword, no additional memory area is required. Note that the reliability of SSD is improved after the manufacturing without cost penalty. Compared with the conventional ECC with the fixed large 32 KByte codeword, the proposed scheme achieves a lower power consumption by introducing the "best-effort" type operation. In the proposed scheme, during the most of the lifetime of SSD, a weak ECC with a shorter codeword such as 512 Byte (+parity), 1 KByte and 2 KByte is used and 98% lower power consumption is realized. At the life-end of SSD, a strong ECC with a 32 KByte codeword is used and the highly reliable operation is achieved. The random read performance is also discussed. The random read performance is estimated by the latency. The latency is below 1.5 ms for ECC codeword up to 32 KByte. This latency is below the average latency of 15,000 rpm HDD, 2 ms.

  14. MREIT experiments with 200μA injected currents: a feasibility study using two reconstruction algorithms, SMM and Harmonic BZ

    Science.gov (United States)

    Arpinar, V E; Hamamura, M J; Degirmenci, E; Muftuler, L T

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as the IEC601. This protocol limits patient auxiliary currents to 100μA for low frequencies. However, published MREIT studies have utilized currents 10 to 400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200μA total injected current and we tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul in 1998 with Tikhonov regularization and the Harmonic BZ proposed by Oh et al in 2003. The reconstruction techniques were tested at both 200μA and 5mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200μA total injected current into a cylindrical phantom generates only 14.7μA current in imaging slice. Similarly, 5mA total injected current results in 367μA in imaging slice. Total acquisition time for 200μA and 5mA experiments were about one

  15. Demonstration of Tokamak ohmic flux saving by transient coaxial helicity injection in the national spherical torus experiment.

    Science.gov (United States)

    Raman, R; Mueller, D; Nelson, B A; Jarboe, T R; Gerhardt, S; Kugel, H W; Leblanc, B; Maingi, R; Menard, J; Ono, M; Paul, S; Roquemore, L; Sabbagh, S; Soukhanovskii, V

    2010-03-05

    Transient coaxial helicity injection (CHI) started discharges in the National Spherical Torus Experiment (NSTX) have attained peak currents up to 300 kA and when coupled to induction, it has produced up to 200 kA additional current over inductive-only operation. CHI in NSTX has shown to be energetically quite efficient, producing a plasma current of about 10 A/J of capacitor bank energy. In addition, for the first time, the CHI-produced toroidal current that couples to induction continues to increase with the energy supplied by the CHI power supply at otherwise similar values of the injector flux, indicating the potential for substantial current generation capability by CHI in NSTX and in future toroidal devices.

  16. Charge-injection-device performance in the high-energy-neutron environment of laser-fusion experiments.

    Science.gov (United States)

    Marshall, F J; DeHaas, T; Glebov, V Yu

    2010-10-01

    Charge-injection devices (CIDs) are being used to image x rays in laser-fusion experiments on the University of Rochester's OMEGA Laser System. The CID cameras are routinely used up to the maximum neutron yields generated (∼10(14) DT). The detectors are deployed in x-ray pinhole cameras and Kirkpatrick-Baez microscopes. The neutron fluences ranged from ∼10(7) to ∼10(9) neutrons/cm(2) and useful x-ray images were obtained even at the highest fluences. It is intended to use CID cameras at the National Ignition Facility (NIF) as a supporting means of recording x-ray images. The results of this work predict that x-ray images should be obtainable on the NIF at yields up to ∼10(15), depending on distance and shielding.

  17. The External-Injection experiment at the SPARC{sub L}AB facility

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Andrea R., E-mail: andrea.rossi@mi.infn.it [INFN - MI, via Celoria 16, 20133 Milan (Italy); Bacci, Alberto [INFN - MI, via Celoria 16, 20133 Milan (Italy); Belleveglia, Marco; Chiadroni, Enrica [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Cianchi, Alessandro [“Tor Vergata” University, Physics Department, via della Ricerca Scientifica 1, 00133 Rome (Italy); INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Di Pirro, Giampiero; Ferrario, Massimo; Gallo, Alessandro; Gatti, Giancarlo [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Maroli, Cesare [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); Mostacci, Andrea [“La Sapienza” University, SBAI Department, via A. Scarpa 14, 00161 Rome (Italy); INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy); Petrillo, Vittoria [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); INFN - MI, via Celoria 16, 20133 Milan (Italy); Serafini, Luca [INFN - MI, via Celoria 16, 20133 Milan (Italy); Tomassini, Paolo [University of Milan, Physics Department, via Celoria 16, 20133 Milan (Italy); Vaccarezza, Cristina [INFN - LNF, v.le E. Fermi, 00044 Frascati (Italy)

    2014-03-11

    At the SPARC{sub L}AB facility of INFN-LNF we are installing a transport lines for ultra-short electron bunches and another for ultra-intense laser pulses, generated by the SPARC photo-injector and by the FLAME laser in a synchronized fashion at the tens of fs level, to co-propagate inside a hydrogen filled glass capillary, in order to perform acceleration of the electron bunch by a plasma wave driven by the laser pulse. The main aim of this experiment is to demonstrate that a high brightness electron beam can be accelerated by a plasma wave without any significant degradation of its quality. Motivations of the technical choices are made and expected performances are reported.

  18. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China.

    Science.gov (United States)

    Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.

  19. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People’s Republic of China

    Science.gov (United States)

    Zhu, Ling-ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People’s Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan–do–check–act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety. PMID:24669192

  20. Corticosteroid injections, eccentric decline squat training and heavy slow resistance training in patellar tendinopathy

    DEFF Research Database (Denmark)

    Kongsgaard, M; Kovanen, V; Aagaard, P

    2009-01-01

    A randomized-controlled single-blind trial was conducted to investigate the clinical, structural and functional effects of peritendinous corticosteroid injections (CORT), eccentric decline squat training (ECC) and heavy slow resistance training (HSR) in patellar tendinopathy. Thirty-nine male...

  1. Multilevel Botulinum Toxin A (Abobotulinum Toxin A Injections in Spastic Forms of Cerebral Palsy: Retrospective Analysis of 8 Russian Centers Experience

    Directory of Open Access Journals (Sweden)

    O. A. Klochkova

    2016-01-01

    Full Text Available Background: The contemporary application of Botulinum toxin A (BTA in cerebral palsy (CP implies multilevel injections both in on-label and off-label muscles. However, there is no single international opinion on the effective and safe dosages, target muscles, and intervals between the injections.Objective: Our aim was to analyze the Russian multicenter independent experience of single and repeated multilevel injections of Abobotulinum toxin А in patients with spastic forms of CP.Methods: 8 independent referral CP-centers (10 hospitals in different regions of Russia. Authors evaluated intervals between the injections, dosages of the BTA for the whole procedure, for the body mass, for the each muscle, and functional segment of the extremities.Results: 1872 protocols of effective BTA injections (1–14 repeated injections for 724 patients with spastic CP were included. The age of the patients was between 8 months to 17 years 4 months at the beginning of the treatment (with a mean of 3 years 10 months. Multilevel BTA injections were indicated for the majority (n = 634, 87.6% of the patients in all the centers. The medians of the dosages for the first BTA injection were between 30–31 U/kg (500 U, the repeated injections doses up to 45 U/kg (1000 U (in most centers. The median intervals between the repeated injections were 180–200 days in 484 (66.9% patients and 140–180 days in 157 (24.7% patients. In 2 centers, children with GMFCS IV–V were injected more often than others.Conclusion: Multilevel BTA injections were indicated for the most patients. The initial dose of Abobotulinum toxin A was 30–31 U/kg. The repeated injections dose could increase up to 40 U/kg. The repeated injections were done in 140–200 days after the previous injection.

  2. [Comparison of corneal endothelial cells after ECCE and phacoemulsification of the lens].

    Science.gov (United States)

    Trnavec, B; Cuvala, J; Cernák, A; Vodrázková, E

    1997-08-01

    The authors evaluate the finding on the corneal endothelium before and after operation of cataract. For examination of the endothelium they used a specular microscope SP 1.000 of Topcon Co. The group comprised 64 eyes of 64 patients. The patients were divided at random into two groups. The first group comprised 26 patients, where ECCE was performed. The second group comprised 38 patients and the opaque lens was removed by phacoemulsification. The mean age in the first group was 69.3 years and in the second group 70.7 years. The same viscoelastic material (methylcellulose) was used and the same synthetic lens from PMMA material was implanted into the capsule. The endothelium was examined one day after operation and on the 7th to 10th day after operation. The following parameters were evaluated: density of the endothelial cells in the centre, mean cell size, polymegethism, coefficient of variation, pleomorphism. In the group of patients who had ECCE the loss of endothelial cells was 18.53%, in the group with phacoemulsification of the nucleus the loss was 16.43%. This difference is not statistically significant. After operation in both groups enlargement of the minimal, maximal as well as mean cell size was observed, the coefficient of variation increased while the grade of cell hexagonality decreased. However these differences in endothelial cells were not statistically significant. After operation of cataract not only endothelial cells are lost but also significant changes in cell morphology occur.

  3. A Provably-Secure ECC-Based Authentication Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Junghyun Nam

    2014-11-01

    Full Text Available A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000. Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC, and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure schemes.

  4. University and place branding: The case of universities located in ECC (European Capital of Culture cities

    Directory of Open Access Journals (Sweden)

    Gábor Rekettye

    2015-03-01

    Full Text Available In the globalising landscape of higher education more and more universities are going international. These universities are facing growing competition, especially in enrolling international students. International competition forces them to use marketing and especially branding activity. University branding requires that the higher education institutions clearly define their differentiating features. One of the most important differentiating features is the place where the institution is located. University and place branding should work together to help the potential students in their decisions to choose the place of their study. The ECC (European Capital of Culture program which started in 1985 has helped many cities to identify their values and to develop their place branding activities. The study examines how the European Capital of Culture designation of the city helped the marketing activities of the universities located in these cities. The study attempts to explore to what extent universities located in ECCs used this special feature of their cities in their international marketing communication. The paper also attempts to analyse the effects the European Capital of Culture title could have on the international student enrolment activity of the concerned universities.

  5. Extended Magnetohydrodynamic Simulations of the Helicity Injected Torus (HIT-SI) Spheromak Experiment with the NIMROD Code

    Science.gov (United States)

    Akcay, Cihan

    A comparative study of 3-D pressureless resistive (single-fluid) magnetohydrodynamic (rMHD) and 3-D pressureless two-fluid magnetohydrodynamic (2fl-MHD) models of the Helicity Injected Torus experiment (HIT-SI) is presented. HIT-SI is a spheromak current-drive experiment that uses two geometrically asymmetric helicity injectors to generate and sustain toroidal plasmas. The goal of the experiment is to demonstrate that steady inductive helicity injection (SIHI) is a viable method for driving and sustaining a magnetized plasma for the eventual purpose of electricity production with magnetic fusion power. The experiment has achieved sustainment of nearly 100 kA of plasma current for ˜1~ms. Fusion power plants are expected to sustain a burning plasma for many minutes to hours with more than 10~MA of plasma current. The purpose of project is to determine the validity of the single-fluid and two-fluid MHD models of HIT-SI. The comparable size of the collisionless ion skin depth to the diameter of the injectors and resistive skin depth predicates the importance of two-fluid effects. The simulations are run with NIMROD (non-ideal magnetohydrodynamics code with rotation-open discussion), an initial-value, 3-D extended MHD code. A constant and uniform plasma density and temperature are assumed. The helicity injectors are modeled as oscillating normal magnetic and parallel electric field boundary conditions. The simulations use parameters that closely match those of the experiment. The simulation output is compared to the formation time, plasma current, and internal and surface magnetic fields. Results of the study indicate 2fl-MHD shows quantitative agreement with the experiment while rMHD only captures the qualitative features. The validity of each model is assessed based on how accurately it reproduces the global quantities as well as the temporal and spatial dependence of the measured magnetic fields. 2fl-MHD produces the current amplification and formation time

  6. NAND flash error correction arithmetic based on ECC embedded BCH code%ECC嵌入BCH码的NAND闪存纠错算法

    Institute of Scientific and Technical Information of China (English)

    李进; 金龙旭; 李国宁; 张珂; 傅瑶; 朱鹏

    2012-01-01

    针对现有闪存基于硬件ECC纠错算法的纠错能力差,而基于RS码和BCH码纠错算法的译码耗时长的问题,提出一种适于空间应用的硬件ECC嵌入BCH码的闪存纠错算法.分析了闪存内部组织结构特点及闪存硬件ECC纠错原理,提出了一种嵌入BCH(2084,2048,3)码的闪存纠错算法.采用一种蝶形阵列处理机制来迭代计算BCH校验码.使用地面检测设备对闪存纠错算法进行了试验验证.结果表明,纠错算法能快速稳定、可靠地工作,在Flash单页2 kB/页下,可以纠正24b错误.该纠错提高了空间相机图像存储系统的可靠性.%In order to resolve the problem of the low error correcting capability of hardware ECC and the being time-consuming of decoder based on RS code or BCH code, a NAND flash error correction algorithm based on hardware ECC embedded BCH code for space application was proposed in this paper. First, this paper presents the structural characteristic of flash. Then the principle of data flash hardware ECC was analyzed. An embedded BCH code error correction arithmetic was put fonvard. Then the check code of BCH encoder was calculated by an 8-bit parallel butterfly array processing mechanism. Finally, the verification experiments to NAND controller in the prototype machine of XX-X space multi-spectral camera were carried out. The experiments results showed that the proposed error correction algorithms can operate fast, efficiently, reliably, and stably. The algorithm is able to correct 24b errors in 2 kB/page. The algorithm can improve the reliability of the space camera data storage.

  7. Mechanical interaction of Engineered Cementitious Composite (ECC) reinforced with Fiber Reinforced Polymer (FRP) rebar in tensile loading

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2010-01-01

    This paper introduces a preliminary study of the composite interaction of Engineered Cementitious Composite (ECC), reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar. The main topic of this paper will focus on the interaction of the two materials (ECC and GFRP) during axial loading......, particularly in post cracking phase of the concrete matrix. The experimental program carried out in this study examined composite behavior under monotonic and cyclic loading of the specimens in the elastic and inelastic deformation phases. The stiffness development of the composite during loading was evaluated...

  8. Simulation of strain-hardening in ECC uniaxial test specimen by use of a damage mechanics formulation

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    This paper discusses the considerations for the establishment of a damage model for ECC. Three different length scales are used in the approach for deriving the damage model. On each length scale important phenomena are investigated by use of numerical and analytical calculations. On the micro...... scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  9. Adapted ECC ozonesonde for long-duration flights aboard boundary-layer pressurised balloons

    Science.gov (United States)

    Gheusi, François; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clenet, Antoine; Derrien, Solène; Doerenbecher, Alexis; El Amraoui, Laaziz; Fontaine, Alain; Hache, Emeric; Jambert, Corinne; Jaumouillé, Elodie; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore

    2016-12-01

    Since the 1970s, the French space agency CNES has developed boundary-layer pressurised balloons (BLPBs) with the capability to transport lightweight scientific payloads at isopycnic level and offer a quasi-Lagrangian sampling of the lower atmosphere over very long distances and durations (up to several weeks).Electrochemical concentration cell (ECC) ozonesondes are widely used under small sounding balloons. However, their autonomy is limited to a few hours owing to power consumption and electrolyte evaporation. An adaptation of the ECC sonde has been developed specifically for long-duration BLPB flights. Compared to conventional ECC sondes, the main feature is the possibility of programming periodic measurement sequences (with possible remote control during the flight). To increase the ozonesonde autonomy, the strategy has been adopted of short measurement sequences (2-3 min) regularly spaced in time (e.g. every 15 min). The rest of the time, the sonde pump is turned off. Results of preliminary ground-based tests are first presented. In particular, the sonde was able to provide correct ozone concentrations against a reference UV-absorption ozone analyser every 15 min for 4 days. Then we illustrate results from 16 BLBP flights launched over the western Mediterranean during three summer field campaigns of the ChArMEx project (http://charmex.lsce.ipsl.fr): TRAQA in 2012, and ADRIMED and SAFMED in 2013. BLPB drifting altitudes were in the range 0.25-3.2 km. The longest flight lasted more than 32 h and covered more than 1000 km. Satisfactory data were obtained when compared to independent ozone measurements close in space and time. The quasi-Lagrangian measurements allowed a first look at ozone diurnal evolution in the marine boundary layer as well as in the lower free troposphere. During some flight segments, there was indication of photochemical ozone production in the marine boundary layer or even in the free troposphere, at rates ranging from 1 to 2 ppbv h -1, which

  10. Modified ECC ozone sonde for long-duration flights aboard isopicnic drifting balloons

    Science.gov (United States)

    Gheusi, Francois; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clénet, Antoine; Fontaine, Alain; Jambert, Corinne; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore

    2015-04-01

    Since few years, the French space agency CNES has developed boundary-layer pressurized balloons (BLPB) with the capability to transport scientific payloads at isopicnic level over very long distances and durations (up to several weeks in absence of navigation limits). However, the autonomy of conventional electrochemical concentration cell (ECC) ozone sondes, that are widely used for tropospheric and stratospheric soundings, is limited to few hours due to power consumption and electrolyte evaporation (owing to air bubbling in the cathode solution). In collaboration with the French research community, CNES has developed a new ozone payload suited for long duration flights aboard BLPB. The mechanical elements (Teflon pump and motor) and the electrochemical cell of conventional ECC sondes have been kept but the electronic implementation is entirely new. The main feature is the possibility of programming periodic measurement sequences -- with possible remote control during the flight. To increase the ozone sonde autonomy, a strategy has been adopted of short measurement sequences (typically 2-3 min) regularly spaced in time (e.g. every 15 min, which is usually sufficient for air quality studies). The rest of the time, the sonde is at rest (pump motor off). The response time of an ECC sonde to an ozone concentration step is below one minute. Consequently, the measurement sequence is typically composed of a one-minute spin-up period after the pump has been turned on, followed by a one- to two-minute acquisition period. All time intervals can be adjusted before and during the flight. Results of a preliminary ground-based test in spring 2012 are first presented. The sonde provided correct ozone concentrations against a reference UV analyzer every 15 minutes during 4 days. Then we illustrate results from 16 BLBP flights launched in the low troposphere over the Mediterranean during summer field campaings in 2012 and 2013 (TRAQA and ChArMEx programmes). BLPB drifting

  11. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China

    Directory of Open Access Journals (Sweden)

    Zhu LL

    2014-03-01

    Full Text Available Ling-ling Zhu,1 Wei Li,2 Ping Song,3 Quan Zhou3 1Geriatric VIP Ward, Division of Nursing, 2Division of Medical Administration, 3Department of Pharmacy, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People's Republic of China Abstract: The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1 improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2 complications associated with vascular access; 3 incidents induced by absence of efficient electronic pump management and infusion tube management; and 4 liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan–do–check–act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety. Keywords

  12. A Secure ECC-based RFID Mutual Authentication Protocol to Enhance Patient Medication Safety.

    Science.gov (United States)

    Jin, Chunhua; Xu, Chunxiang; Zhang, Xiaojun; Li, Fagen

    2016-01-01

    Patient medication safety is an important issue in patient medication systems. In order to prevent medication errors, integrating Radio Frequency Identification (RFID) technology into automated patient medication systems is required in hospitals. Based on RFID technology, such systems can provide medical evidence for patients' prescriptions and medicine doses, etc. Due to the mutual authentication between the medication server and the tag, RFID authentication scheme is the best choice for automated patient medication systems. In this paper, we present a RFID mutual authentication scheme based on elliptic curve cryptography (ECC) to enhance patient medication safety. Our scheme can achieve security requirements and overcome various attacks existing in other schemes. In addition, our scheme has better performance in terms of computational cost and communication overhead. Therefore, the proposed scheme is well suitable for patient medication systems.

  13. General description of KAERI LBLOCA realistic evaluation model (REM) for ECCS evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Yong; Lee, Young Jin; Chung, Bub Dong; Lee, Won Jae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    A realistic evaluation model (REM) for LBLOCA licensing calculation is developed for application to pressurezed ligh water reactors. The developmental aim of the KAERI-REM is to provide a systematic methodology that is simple in structure and to used and built upon sound logical reasoning, for improving the code capability to realistically describe the LBLOCA phenomena and for evaluating the associated uncertainties. The method strives to be faithful to the intention of being best-estimate, that is, the method aims to evaluate the best-estimate values and the associated uncertainties while complying to the requirements in the ECCS regulations. As a demonstration, KAERI-REM was applied to quantify the safety margin for LBLOCA for Kori 3 and 4 and appended to this report. (Author) 11 refs., 2 figs., 6 tabs.

  14. Cost-minimization analysis of capsulotomy after ECCE and IOL implantation.

    Science.gov (United States)

    Lertsumitkul, S; La Nauze, J

    1996-06-01

    An economic evaluation of capsulotomy for posterior capsular opacification after extracapsular cataract extraction (ECCE) and intraocular lens (IOL) implantation was carried out using a cost minimization model. This model demonstrates the use of cost comparison to aid the decision making process. A flow-chart of capsulotomy mode, with associated complications, is illustrated. Costs of complications are calculated using assigned probability for each tree. Overall comparative costs are displayed graphically Further, the model is presented using a computer-assisted spreadsheet with an added calculation program. Variables can therefore be adjusted with instantaneous outcomes visually displayed. We present several examples with different sets of variables and find that, in most instances, YAG capsulotomy is a more economical option than surgical capsulotomy. This finding is a relevant finding in planning for eye health programs, particularly in developing countries. We suggest that the model be modified using local parameters in order to provide optimal benefits in similar health programs.

  15. Computer Simulation of the E.C.C.S. Buckling Curve using a Monte-Carlo Method

    NARCIS (Netherlands)

    Strating, J.; Vos, H.

    1973-01-01

    The application of a Monte-Carlo simulation procedure to obtain the distribution function of the maximum load of a hinged column with imperfections is discussed. Buckling tests carried out by the E.C.C.S. on IPE 160 sections have been simulated. Information concerning the column variables is obtaine

  16. Incorporating Indigenous Knowledge and Practice into ECCE: A Comparison of Programs in The Gambia, Senegal and Mali

    Science.gov (United States)

    Soudee, Alicia Ranck

    2009-01-01

    Early Childhood Development (ECD) has emerged as a theme in international and African dialogue on education in recent years. UNESCO's Division of Basic Education Early Childhood promotes an integrated approach to Early Childhood Care and Education (ECCE) policy development and review. The study examines how this is implemented in three West…

  17. Parametric study of the potential for BWR ECCS strainer blockage due to LOCA generated debris. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Zigler, G.; Brideau, J.; Rao, D.V.; Shaffer, C.; Souto, F.; Thomas, W. [Science and Engineering Associates, Inc., Albuquerque, NM (United States)

    1995-10-01

    This report documents a plant-specific study for a BWR/4 with a Mark I containment that evaluated the potential for LOCA generated debris and the probability of losing long term recirculation capability due ECCS pump suction strainer blockage. The major elements of this study were: (1) acquisition of detailed piping layouts and installed insulation details for a reference BWR; (2) analysis of plant specific piping weld failure probabilities to estimate the LOCA frequency; (3) development of an insulation and other debris generation and drywell transport models for the reference BWR; (4) modeling of debris transport in the suppression pool; (5) development of strainer blockage head loss models for estimating loss of NPSH margin; (6) estimation of core damage frequency attributable to loss of ECCS recirculation capability following a LOCA. Elements 2 through 5 were combined into a computer code, BLOCKAGE 2.3. A point estimate of overall DEGB pipe break frequency (per Rx-year) of 1.59E-04 was calculated for the reference plant, with a corresponding overall ECCS loss of NPSH frequency (per Rx-year) of 1.58E-04. The calculated point estimate of core damage frequency (per Rx-year) due to blockage related accident sequences for the reference BWR ranged from 4.2E-06 to 2.5E-05. The results of this study show that unacceptable strainer blockage and loss of NPSH margin can occur within the first few minutes after ECCS pumps achieve maximum flows when the ECCS strainers are exposed to LOCA generated fibrous debris in the presence of particulates (sludge, paint chips, concrete dust). Generic or unconditional extrapolation of these reference plant calculated results should not be undertaken.

  18. 挤压铸造设备压射运动参数的实验研究%Experiment Research for Injection Movement Parameters of Squeeze Casting Equipment

    Institute of Scientific and Technical Information of China (English)

    宋雷; 邵明

    2014-01-01

    Injection is one of key function of squeeze casting equipment, movement parameters vitally effect the quality of castings. Through experiment research for injection movement parameters, obvious fluctuation of injection velocity is found, the analysis for cause of velocity fluctuation is carried out, and improved suggestion is proposed.%压射功能是挤压铸造设备的核心功能之一,压射过程的运动参数是对铸件的质量有着重要的影响。通过对压射运动参数进行实验研究,发现压射速度存在明显的波动,并对造成压射速度波动的主要原因进行分析,提出了改进建议。

  19. “We don’t need services. We have no problems”: exploring the experiences of young people who inject drugs in accessing harm reduction services

    Directory of Open Access Journals (Sweden)

    Anita Krug

    2015-02-01

    Full Text Available Introduction: Evidence suggests that people who inject drugs often begin their drug use and injecting practices in adolescence, yet there are limited data available on the HIV epidemic and the responses for this population. The comprehensive package of interventions for the prevention, treatment and care of HIV infection among people who inject drugs first laid out in 2009 (revised in 2012 by World Health Organization, United Nations Office of Drugs and Crime and Joint United Nations Programme on HIV/AIDS, does not consider the unique needs of adolescent and young people. In order to better understand the values and preferences of young people who inject drugs in accessing harm reduction services and support, we undertook a series of community consultations with young people with experience of injecting drugs during adolescence. Methods: Community consultations (4–14 persons were held in 14 countries. Participants were recruited using a combined criterion and maximum variation sampling strategy. Data were analyzed using collaborative qualitative data analysis. Frequency analysis of themes was conducted. Results: Nineteen community consultations were organized with a total of 132 participants. All participants had experienced injecting drugs before the age of 18. They had the following age distribution: 18–20 (37%, 21–25 (48% and 26–30 (15%. Of the participants, 73.5% were male while 25.7% were female, with one transgender participant. Barriers to accessing the comprehensive package included: lack of information and knowledge of services, age restrictions on services, belief that services were not needed, fear of law enforcement, fear of stigma, lack of concern, high cost, lack of outreach, lack of knowledge of HCV/TB and lack of youth friendly services. Conclusions: The consultations provide a rare insight into the lived experiences of adolescents who inject drugs and highlight the dissonance between their reality and current policy and

  20. Subcutaneous injection of thallium-201 chloride and gallium-67 citrate at acupuncture point K-3; An animal experiment and human-being study

    Energy Technology Data Exchange (ETDEWEB)

    Johg, Shiang-Bin; Wu, Chung-Chieng; Chen, Ming-Feng; Wu, Sheng-Nan (Kaohsiung Medical Coll., Taiwan (China))

    1992-09-01

    Subcutaneous (SC) injection of [sup 99m]Tc pertechnetate ([sup 99m]Tc) at acupuncture points K-3 is a new method of lower-limb radionuclide venography. To investigate the mechanism of absorption of [sup 99m]Tc from SC injected sites into vascular system, various radioisotopes such as [sup 201]Tl chloride ([sup 201]Tl) and [sup 67]Ga citrate ([sup 67]Ga) were SC injected at K-3 points in animal and human-beings experiments. It was found that [sup 99m]Tc and [sup 201]Tl were absorbed rapidly from K-3 points through venous system and into whole body soft tissue. However, [sup 67]Ga with a larger effective ionic radius than [sup 201]Tl was not absorbed throughout the observation of 5 minutes. Furthermore, intravenous administration of digitalis, a Na[sup +]-K[sup +] pump blocker, did not inhibit the absorption of [sup 99m]Tc and [sup 201]Tl after SC injection at K-3 points. These results suggest that absorption of radionuclides on SC injection at K-3 points is mainly through the passive pathway of diffusion rather than the active transport, and the effective ionic radius may be a major factor influencing the absorption rate of the radionuclides. (author).

  1. Effects of intra-prelimbic prefrontal cortex injection of cannabidiol on anxiety-like behavior: involvement of 5HT1A receptors and previous stressful experience.

    Science.gov (United States)

    Fogaça, M V; Reis, F M C V; Campos, A C; Guimarães, F S

    2014-03-01

    The prelimbic medial prefrontal cortex (PL) is an important encephalic structure involved in the expression of emotional states. In a previous study, intra-PL injection of cannabidiol (CBD), a major non-psychotomimetic cannabinoid present in the Cannabis sativa plant, reduced the expression of fear conditioning response. Although its mechanism remains unclear, CBD can facilitate 5HT1A receptor-mediated neurotransmission when injected into several brain structures. This study was aimed at verifying if intra-PL CBD could also induce anxiolytic-like effect in a conceptually distinct animal model, the elevated plus maze (EPM). We also verified if CBD effects in the EPM and contextual fear conditioning test (CFC) depend on 5HT1A receptors and previous stressful experience. CBD induced opposite effects in the CFC and EPM, being anxiolytic and anxiogenic, respectively. Both responses were prevented by WAY100,635, a 5HT1A receptor antagonist. In animals that had been previously (24h) submitted to a stressful event (2h-restraint) CBD caused an anxiolytic, rather than anxiogenic, effect in the EPM. This anxiolytic response was abolished by previous injection of metyrapone, a glucocorticoid synthesis blocker. Moreover, restraint stress increased 5HT1A receptors expression in the dorsal raphe nucleus, an effect that was attenuated by injection of metyrapone before the restraint procedure. Taken together, these results suggest that CBD modulation of anxiety in the PL depend on 5HT1A-mediated neurotransmission and previous stressful experience.

  2. Design process of the nanofluid injection mechanism in nuclear power plants.

    Science.gov (United States)

    Kang, Myoung-Suk; Jee, Changhyun; Park, Sangjun; Bang, In Choel; Heo, Gyunyoung

    2011-04-27

    Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs). This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs) assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD) in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner.

  3. Design process of the nanofluid injection mechanism in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Bang In Choel

    2011-01-01

    Full Text Available Abstract Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs. This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner.

  4. Medroxyprogesterone Injection

    Science.gov (United States)

    Medroxyprogesterone intramuscular (into a muscle) injection and medroxyprogesterone subcutaneous (under the skin) injection are used to prevent pregnancy. Medroxyprogesterone subcutaneous injection is also used to treat endometriosis (a condition in which ...

  5. Pentamidine Injection

    Science.gov (United States)

    Pentamidine injection is used to treat pneumonia caused by a fungus called Pneumocystis carinii. It is in ... Pentamidine injection comes as powder to be mixed with liquid to be injected intramuscularly (into a muscle) ...

  6. Secure Cluster Based Routing Using SAT/ILP Techniques and ECC EL-Gamal Threshold Cryptography in MANET

    Directory of Open Access Journals (Sweden)

    Mr. P. Kanagaraju. Me, (Ph. D

    2014-03-01

    Full Text Available The Elliptic curve cryptography ( ECC a promising and important because it requires less computing power, bandwidth, and also the memory when comparing to other cryptosystems The clustering algorithm using the Integer Linear Programming (ILP and Boolean Satisfiability (SAT solvers. These improvements will secure the application of SAT and ILP techniques in modeling composite engineering problem that is the Clustering Problem in Mobile Ad-Hoc Networks (MANETs. The Clustering Problem in MANETs consists of selecting the most appropriate nodes of a given MANET topology as clusterheads, and ensuring that regular nodes are related to clusterheads such that the lifetime of the network is maximized. In which, discussing SAT/ILP techniques for clustering techniques and ECC El Gamal Threshold Cryptography for the security. Through our implementation, explored the possibility of using ECCEG-TC in MANETs.

  7. Ageing and COPD affect different domains of nutritional status: the ECCE study.

    Science.gov (United States)

    Battaglia, S; Spatafora, M; Paglino, G; Pedone, C; Corsonello, A; Scichilone, N; Antonelli-Incalzi, R; Bellia, V

    2011-06-01

    Chronic obstructive pulmonary disease (COPD) and ageing may contribute to malnutrition. We aimed to explore whether COPD and ageing determine malnutrition in different manners. 460 stable COPD outpatients (376 males and 84 females) from the Extrapulmonary Consequences of COPD in the Elderly (ECCE) study database were investigated (age 75.0±5.9 yrs; forced expiratory volume in 1 s 54.7±18.3% predicted). Nutritional status was evaluated using the Mini Nutritional Assessment® (MNA) questionnaire. From the MNA, three scores exploring the domains of the nutritional status were calculated: body composition, energy intake and body functionality scores. Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages were negatively correlated with five MNA items exploring mobility, patient's perception of own nutrition and health status, and arm and calf circumferences (lowest Spearman's rho (rs)=-0.011; highest p=0.039). GOLD stages were independently correlated with body composition and body functionality scores (model r2=0.073). Age was negatively correlated with four MNA items exploring loss of appetite, fluid intake, mobility and autonomy in daily life (lowest rs=-0.013; highest p=0.030). Age was independently correlated with body functionality score (model r2=0.037). Severe COPD and ageing are independent and probably concurrent conditions leading to malnutrition. The MNA questionnaire allows a valuable insight into the complexity of components of nutritional status and may provide useful clues for treatment strategies.

  8. Estimated net value and uncertainty for automating ECCS switchover at PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, B.; Brideau, J.; Comes, L.; Darby, J.; Guttmann, H.; Sciacca, F.; Souto, F.; Thomas, W.; Zigler, G. [Science and Engineering Associates, Inc., Albuquerque, NM (United States)

    1996-02-01

    Question for resolution of Generic Safety Issue No. 24 is whether or not PWRs that currently rely on a manual system for ECCS switchover to recirculation should be required to install an automatic system. Risk estimates are obtained by reevaluating the contributions to core damage frequencies (CDFs) associated with failures of manual and semiautomatic switchover at a representative PWR. This study considers each separate instruction of the corresponding emergency operating procedures (EOPs), the mechanism for each control, and the relation of each control to its neighbors. Important contributions to CDF include human errors that result in completely coupled failure of both trains and failure to enter the required EOP. It is found that changeover to a semiautomatic system is not justified on the basis of cost-benefit analysis: going from a manual to a semiautomatic system reduces the CDF by 1.7 {times} 10{sup {minus}5} per reactor-year, but the probability that the net cost of the modification being less than $1, 000 per person-rem is about 20% without license renewal. Scoping analyses, using optimist assumptions, were performed for a changeover to a semiautomatic system with automatic actuation and to a fully automatic system; in these cases the probability of a net cost being less than $1,000/person-rem is about 50% without license renewal and over 95% with license renewal.

  9. Dynamic investigation of nutrient consumption and injection strategy in microbial enhanced oil recovery (MEOR) by means of large-scale experiments.

    Science.gov (United States)

    Song, Zhiyong; Zhu, Weiyao; Sun, Gangzheng; Blanckaert, Koen

    2015-08-01

    Microbial enhanced oil recovery (MEOR) depends on the in situ microbial activity to release trapped oil in reservoirs. In practice, undesired consumption is a universal phenomenon but cannot be observed effectively in small-scale physical simulations due to the scale effect. The present paper investigates the dynamics of oil recovery, biomass and nutrient consumption in a series of flooding experiments in a dedicated large-scale sand-pack column. First, control experiments of nutrient transportation with and without microbial consumption were conducted, which characterized the nutrient loss during transportation. Then, a standard microbial flooding experiment was performed recovering additional oil (4.9 % Original Oil in Place, OOIP), during which microbial activity mostly occurred upstream, where oil saturation declined earlier and steeper than downstream in the column. Subsequently, more oil remained downstream due to nutrient shortage. Finally, further research was conducted to enhance the ultimate recovery by optimizing the injection strategy. An extra 3.5 % OOIP was recovered when the nutrients were injected in the middle of the column, and another additional 11.9 % OOIP were recovered by altering the timing of nutrient injection.

  10. Assessment of RELAP5/MOD3.1 for gravity-driven injection experiment in the core makeup tank of the CARR Passive Reactor (CP-1300)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.I.; No, H.C. [Korea Advanced Inst. of Science and Technology, Yusung, Taejon (Korea, Republic of). Nuclear Engineering Dept.; Bang, Y.S.; Kim, H.J. [Korea Inst. of Nuclear Safety, Yusung Taejon (Korea, Republic of). Advanced Reactor Dept.

    1996-10-01

    The objective of the present work is to improve the analysis capability of RELAP5/MOD3.1 on the direct contact condensation in the core makeup tank (CMT) of passive high-pressure injection system (PHPIS) in the CARR Passive Reactor (CP-1300). The gravity-driven injection experiment is conducted by using a small scale test facility to identify the parameters having significant effects on the gravity-driven injection and the major condensation modes. It turns out that the larger the water subcooling is, the more initiation of injection is delayed, and the sparger and the natural circulation of the hot water from the steam generator accelerate the gravity-driven injection. The condensation modes are divided into three modes: sonic jet, subsonic jet, and steam cavity. RELAP5/MOD3.1 is chosen to evaluate the cod predictability on the direct contact condensation in the CMT. It is found that the predictions of MOD3.1 are in better agreement with the experimental data than those of MOD3.0. From the nodalization study of the test section, the 1-node model shows better agreement with the experimental data than the multi-node models. RELAP5/MOD3.1 identifies the flow regime of the test section as vertical stratification. However, the flow regime observed in the experiment is the subsonic jet with the bubble having the vertical cone shape. To accurately predict the direct contact condensation in the CMT with RELAP5/MOD3.1, it is essential that a new set of the interfacial heat transfer coefficients and a new flow regime map for direct contact condensation in the CMT be developed.

  11. Perspectives and experiences of Dutch multiple sclerosis patients and multiple sclerosis-specialized neurologists on injectable disease-modifying treatment

    NARCIS (Netherlands)

    Visser, Leo H.; Heerings, Marco A.; Jongen, Peter J.; van der Hiele, Karin

    2016-01-01

    Background: The adherence to treatment with injectable disease-modifying drugs (DMDs) in multiple sclerosis (MS) may benefit from adequate information provision and management of expectations. The communication between patients and physicians is very important in this respect. The current study inve

  12. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  13. Laboratory experiments simulating poroelastic stress changes associated with depletion and injection in low-porosity sedimentary rocks

    Science.gov (United States)

    Ma, Xiaodong; Zoback, Mark D.

    2017-04-01

    We characterized the poroelastic deformation of six cores from three formations associated with the Bakken play in the Williston Basin (the Lodgepole, Middle Bakken, and Three Forks formations). All are low-porosity, low-permeability formations, but vary considerably in clay, kerogen, and carbonate content. The experimental program simulated reservoir stress changes associated with depletion and injection via cycling both the confining pressure (Pc) and pore pressure (Pp). We measured volumetric strain, derived the corresponding bulk modulus, and calculated the Biot coefficient (α). We found α, which generally ranges between 0.3 and 0.9, to vary systematically with Pc and Pp for each of the specimens tested. The effect of pore pressure on α is much larger at low simple effective stress (σ = Pc-Pp) during depletion than injection. The α decreases with σ for all pore pressures. For the same Pc and Pp, the Biot coefficient is consistently higher during injection than during depletion. Given the observed variations of α with Pc and Pp, the modeling of reservoir stress changes using a constant α could be problematic as poroelastic stress changes during depletion and injection are not likely to follow the same path. Scanning electron microscope examination of microstructures suggests that the variations of the bulk modulus and the Biot coefficient can be attributed to the abundance of compliant components (pores, microcracks, clays, and organic matter) and how they are distributed throughout the rock matrix.

  14. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  15. Design of a single-phase PTS numerical experiment for a reference Direct Numerical Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Shams, A., E-mail: shams@nrg.eu; Damiani, G.; Rosa, D.; Komen, E.M.J.

    2016-04-15

    Highlights: • A numerical experiment is designed to perform DNS for a PTS scenario. • A wide range of RANS calculations are performed to design this numerical experiment. • Mesh estimation for the targeted DNS is also performed. - Abstract: The integrity assessment of the Reactor Pressure Vessel (RPV) is considered to be an important issue for lifetime extension of nuclear reactors. A severe transient that can threaten the integrity of the RPV is the existence of a Pressurized Thermal Shock (PTS) during a Loss-of-Coolant Accident (LOCA). A PTS consists of a rapid cooling of the RPV wall under pressurized conditions that may induce the criticality of existing or postulated defects inside the vessel wall. The most severe PTS event has been identified by Emergency Core Cooling (ECC) injection during a LOCA. The traditional one-dimensional system codes fail to reliably predict the complex three-dimensional thermal mixing phenomena in the downcomer occurring during the ECC injection. Hence, CFD can bring real benefits in terms of more realistic and more predictive capabilities. However, to gain trust in the application of CFD modelling for PTS, a comprehensive validation programme is necessary. In the absence of detailed experimental data for the RPV cooling during ECC injection, high fidelity Direct Numerical Simulation (DNS) databases constitute a valid alternative and can serve as a reference. The aim of this work is to design a numerical experiment aimed to generate a high quality reference DNS database for a simplified PTS scenario. This takes into account the turbulent mixing in the downcomer and the evolution of the temperature distribution for both structures and fluid during a single-phase flow PTS scenario. In spite of simplifications, such a DNS analysis represents a very demanding application. A priori, it should be demonstrated that all the relevant turbulent scales will be fully resolved, which requires a huge computational power. A wide range of

  16. Comparison of results and complications following combined ECCE-trabeculectomy versus small-incision-trabeculectomy and posterior chamber lens implantation.

    Science.gov (United States)

    Wedrich, A; Menapace, R; Hirsch, U; Papapanos, P; Derbolav, A; Ries, E

    To compare the efficacy and complication rate of two standard cataract extraction techniques with different incision lengths when combined with trabeculectomy. 54 eyes after combined ECCE, posterior chamber lens implantation and trabeculectomy (ECCE-group) are compared with 49 eyes following phacoemulsification, trabeculectomy and implantation of a folded flexible posterior chamber lens (small-incision group). Minimum follow-up was 24 months. Glaucoma control was achieved in all eyes of both groups. There was a tendency towards a higher number of patients without therapy in the small-incision group (82% versus 65%, p = 0.07). Final mean IOP (14.2 +/- 3.0 mmHg versus 15.5 +/- 2.7 mmHg, p = 0.02) and mean therapy index (0.2 +/- 0.5 versus 0.4 +/- 0.6, p = 0.03) were significantly lower in the small-incision group. Postoperative complications such as severe fibrin effusion (41% versus 18%, p = 0.018), early postoperative IOP rises > 25 mmHg (18% versus 2%, p = 0.009), filtering bleb scarring (63% versus 8%, p ECCE-group. With the decrease of the incision size necessary for the cataract extraction a reduction of postoperative complications and better functional results are achieved in combined cataract/glaucoma surgery.

  17. Numerical simulation of boron injection in a BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tinoco, Hernan, E-mail: htb@forsmark.vattenfall.s [Forsmarks Kraftgrupp AB, SE-742 03 Osthammar (Sweden); Buchwald, Przemyslaw [Reactor Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Frid, Wiktor, E-mail: wiktor@reactor.sci.kth.s [Reactor Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden)

    2010-02-15

    The present study constitutes a first step to understand the process of boron injection, transport and mixing in a BWR. It consists of transient CFD simulations of boron injection in a model of the downcomer of Forsmark's Unit 3 containing about 6 million elements. The two cases studied are unintentional start of boron injection under normal operation and loss of offsite power with partial ATWS leaving 10% of the core power uncontrolled. The flow conditions of the second case are defined by means of an analysis with RELAP5, assuming boron injection start directly after the first ECCS injection. Recent publications show that meaningful conservative results may be obtained for boron or thermal mixing in PWRs with grids as coarse as that utilized here, provided that higher order discretization schemes are used to minimize numerical diffusion. The obtained results indicate an apparently strong influence of the scenario in the behavior of the injection process. The normal operation simulation shows that virtually all boron solution flows down to the Main Recirculation Pump inlet located directly below the boron inlet nozzle. The loss of offsite power simulation shows initially a spread of the boron solution over the entire sectional area of the lower part of the downcomer filled with colder water. This remaining effect of the ECCS injection lasts until all this water has left the downcomer. Above this region, the boron injection jet develops in a vertical streak, eventually resembling the injection of the normal operation scenario. Due to the initial spread, this boron injection will probably cause larger temporal and spatial concentration variations in the core. In both cases, these variations may cause reactivity transients and fuel damage due to local power escalation. To settle this issue, an analysis using an extended model containing the downcomer, the MRPs and the Lower Plenum will be carried out. Also, the simulation time will be extended to a scale of

  18. Comparison of allele frequency for HLA-DR and HLA-DQ between patients with ECC and caries-free children

    Directory of Open Access Journals (Sweden)

    Bagherian A

    2008-03-01

    Full Text Available Background: Early childhood caries (ECC is one of the most common diseases of childhood. The etiology of ECC is multifactorial and both genetic and environmental factors play important roles in the pathogenesis of the disease. Genetic variations in the hosts may contribute to changes in the risk for dental caries. Genetic factors such as human leukocyte antigen (HLA have recently been suggested as a predisposing factor. Aim: The aim of this study was to look for an association between HLA-DRB1 and HLA-DQB1 with ECC for developing new strategies for the diagnosis as well as the prevention of the disease. Design: In this study, we extracted the genomic DNAs from whole blood samples of 44 patients with ECC and 35 caries-free children by the salting-out method. We amplified the genomic DNA by PCR-SSP and then HLA-typing was performed for all alleles. Results: The results revealed a significant increase in the frequency of HLA-DRB1FNx0104 in the patient group (P = 0.019. The odds ratio for this allele was detected to be 10. The frequency of HLA-DQB1 alleles was not significantly different between the two groups. Conclusion: The above results suggest that HLA-DRB1FNx0104 is associated with the susceptibility to ECC. Thus HLA-DRB1FNx0104 detection as a molecular marker for early diagnosis of ECC may be recommended.

  19. Preventing Sciatic Nerve Injury due to Intramuscular Injection: Ten-Year Single-Center Experience and Literature Review.

    Science.gov (United States)

    Geyik, Sirma; Geyik, Murat; Yigiter, Remzi; Kuzudisli, Samiye; Saglam, Sadullah; Elci, Mehmet Ali; Yilmaz, Mustafa

    2017-01-01

    Sciatic nerve injury is the most frequent and serious complication of intramuscular gluteal injection. This study aims to highlight the incidence and causes of this continuing problem and to discuss the relevant literature. problems is relatively rare. We suggest a double quadrant drawing technique in each gluteal region. We also draw attention to this issue with postgraduate and in-service training programs of medical staff, and providing continuity in education can reduce this serious complication.

  20. Intratumor photosensitizer injection for photodynamic therapy: Pre-clinical experience with methylene blue, Pc 4, and Photofrin

    Science.gov (United States)

    Baran, Timothy M.; Foster, Thomas H.

    2016-03-01

    Intravenous administration of some photosensitizers, including the FDA-approved Photofrin, results in significant systemic photosensitivity and a 2-3-day drug-light interval. Direct intratumor injection of photosensitizer could potentially eliminate these negative aspects of photodynamic therapy (PDT), while requiring a lower photosensitizer dose to achieve comparable drug concentration in the target tissue. We performed PDT using intratumor injection of 3 photosensitizers, methylene blue (MB), Pc 4, and Photofrin, in mouse tumor models. After a 0-15 minute drug-light interval, illumination was delivered by appropriate diode lasers. For animals receiving MB or Pc 4, surface illumination was delivered using a microlens-terminated fiber. For animals receiving Photofrin, interstitial illumination was delivered by a 1 cm diffuser. In animals receiving MB or Pc 4, tumor dimensions were measured daily post-PDT, with a cure being defined as no palpable tumor 90 days post-treatment. For Photofrin, animals were sacrificed 24 hours post-PDT and tumors were excised, with samples HE stained to assess PDT-induced necrosis. 55% of tumors were cured with MB-PDT, and significant tumor growth delay (p=0.002) was observed for Pc 4. For Photofrin PDT, the mean necrosis radius was 3.4+/-0.8 mm, compared to 2.9+/-1.3 mm for systemic administration, which was not a significant difference (p=0.58). Intratumoral injection of the photosensitizers methylene blue, Pc 4, and Photofrin is feasible, and results in appreciable tumor response. Further investigation is necessary to optimize treatment protocols and assess the systemic photosensitivity induced by intratumor injection.

  1. Simulation of injector dynamics during steady inductive helicity injection current drive in the HIT-SI experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C., E-mail: hansec@uw.edu [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Columbia University, New York, New York 10027 (United States); Marklin, G. [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Victor, B. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); Akcay, C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Jarboe, T. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); PSI-Center, University of Washington, Seattle, Washington 98195 (United States)

    2015-04-15

    We present simulations of inductive helicity injection in the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) device that treats the entire plasma volume in a single dynamic MHD model. A new fully 3D numerical tool, the PSI-center TETrahedral mesh code, was developed that provides the geometric flexibility required for this investigation. Implementation of a zero-β Hall MHD model using PSI-TET will be presented including formulation of a new self-consistent magnetic boundary condition for the wall of the HIT-SI device. Results from simulations of HIT-SI are presented focusing on injector dynamics that are investigated numerically for the first time. Asymmetries in the plasma loading between the two helicity injectors and progression of field reversal in each injector are observed. Analysis indicates cross-coupling between injectors through confinement volume structures. Injector impedance is found to scale with toroidal current at fixed density, consistent with experimental observation. Comparison to experimental data with an injector drive frequency of 14.5 kHz shows good agreement with magnetic diagnostics. Global mode structures from Bi-Orthogonal decomposition agree well with experimental data for the first four modes.

  2. Managing la malilla: Exploring drug treatment experiences among injection drug users in Tijuana, Mexico, and their implications for drug law reform.

    Science.gov (United States)

    Syvertsen, Jennifer; Pollini, Robin A; Lozada, Remedios; Vera, Alicia; Rangel, Gudelia; Strathdee, Steffanie A

    2010-11-01

    In August 2009, Mexico reformed its drug laws and decriminalized small quantities of drugs for personal use; offenders caught three times will be mandated to enter drug treatment. However, little is known about the quality or effectiveness of drug treatment programs in Mexico. We examined injection drug users' (IDUs) experiences in drug treatment in Tijuana, Mexico, with the goal of informing program planning and policy. We examined qualitative and quantitative data from Proyecto El Cuete, a multi-phased research study on HIV risk among IDUs in Tijuana. Phase I consisted of 20 in-depth interviews and Phase II employed respondent-driven sampling to recruit 222 IDUs for a quantitative survey. We also reviewed national drug policy documents, surveillance data, and media reports to situate drug users' experiences within the broader sociopolitical context. Participants in the qualitative study were 50% male with a mean age of 32; most injected heroin (85.0%) and methamphetamine (60.0%). The quantitative sample was 91.4% male with a mean age of 35; 98.2% injected heroin and 83.7% injected heroin and methamphetamine together. The majority of participants reported receiving treatment: residential treatment was most common, followed by methadone; other types of services were infrequently reported. Participants' perceptions of program acceptability and effectiveness were mixed. Mistreatment emerged as a theme in the qualitative interviews and was reported by 21.6% of Phase II participants, primarily physical (72.0%) and verbal (52.0%) abuse. Our results point to the need for political, economic, and social investment in the drug treatment system before offenders are sentenced to treatment under the revised national drug law. Resources are needed to strengthen program quality and ensure accountability. The public health impact of the new legislation that attempts to bring drug treatment to the forefront of national drug policy should be systematically evaluated. Copyright

  3. Un ejemplo de constitución genérica en la literatura espiritual: el «paso» del Ecce Homo

    Directory of Open Access Journals (Sweden)

    Pego Puigbó, Armando

    2001-12-01

    Full Text Available Spiritual Literature represents a very special branch within the literary system. In this article the genre of the «paso», which is completely different from the dramatic one, will be discussed beyond the traditional approches, based on thematic, formal and discoursive features. In this way, in the «paso» a possible connection of a literary kind with a kind of knowledge and experience is proposed. The Renaissance Genre-Theory can provide a view which allows us to surpass the narrow frame of mimesis. The literary kind is opened to the world, which is represented through the communicative powers of rhetoric devices. The «paso» belongs to the epidictic genre. The praise of Christ adopts the narration of a passage taken out from the Passion, according to figurae sententiae waiting for affective answers. But its spiritual condition is produced by cultural implications which warrant the correct interpretation of its meanings. Examples of Ecce homo by Francisco de Osuna, Juan de Ávila and fray Luis de Granada are analysed according to this purpose.La literatura espiritual representa una rama muy especial dentro del sistema literario. En este artículo, se discutirá el género del «paso», en nada parecido a su homónimo dramático, más allá de los criterios temático, formal y discursivo. En el «paso» puede proponerse una posible conexión entre una clase literaria y una clase de conocimiento y experiencia. La teoría renacentista de los géneros es capaz de ofrecer una perspectiva que supera el estrecho marco de la mímesis. La clase literaria se abre al mundo real, representado por medio de la fuerza comunicativa de los procedimientos retóricos. En este sentido el «paso» pertenece al género epidíctico en cuanto que la alabanza de Cristo adopta la forma de una narración extraída del relato de la Pasión. Las figuras de pensamiento buscan una respuesta afectiva, cuyo empleo y sentido son correctamente interpretados a través de

  4. Doripenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such ... if you are allergic to doripenem injection; other carbapenem antibiotics such as imipenem/cilastatin (Primaxin) or meropenem ( ...

  5. Methotrexate Injection

    Science.gov (United States)

    Methotrexate injection is used alone or in combination with other medications to treat gestational trophoblastic tumors (a ... in bones) after surgery to remove the tumor. Methotrexate injection is also used to treat severe psoriasis ( ...

  6. Bendamustine Injection

    Science.gov (United States)

    Bendamustine injection is used to treat chronic lymphocytic leukemia (CLL; a type of cancer of the white ... injection. You should use birth control to prevent pregnancy in yourself or your partner during your treatment ...

  7. Caspofungin Injection

    Science.gov (United States)

    Caspofungin injection is used in adults and children 3 months of age and older to treat yeast ... people with a weakened ability to fight infection. Caspofungin injection is in a class of antifungal medications ...

  8. Temozolomide Injection

    Science.gov (United States)

    Temozolomide is used to treat certain types of brain tumors. Temozolomide is in a class of medications called alkylating ... Temozolomide injection comes as a powder to be added to fluid and injected over 90 minutes intravenously ( ...

  9. Pembrolizumab Injection

    Science.gov (United States)

    Pembrolizumab injection is used to treat melanoma (a type of skin cancer) that cannot be treated with ... who have a specific type of melanoma tumor. Pembrolizumab injection is also used to treat a certain ...

  10. Lacosamide Injection

    Science.gov (United States)

    ... injection is in a class of medications called anticonvulsants. It works by decreasing abnormal electrical activity in ... older (about 1 in 500 people) who took anticonvulsants like lacosamide injection to treat various conditions during ...

  11. Midazolam Injection

    Science.gov (United States)

    ... injection is in a class of medications called benzodiazepines. It works by slowing activity in the brain ... breast-feeding.talk to your doctor about the risks and benefits of receiving midazolam injection if you ...

  12. Doxycycline Injection

    Science.gov (United States)

    Doxycycline injection is used to treat or prevent bacterial infections, including pneumonia and other respiratory tract infections. ... certain skin, genital, intestine, and urinary system infections. Doxycycline injection may be used to treat or prevent ...

  13. Paclitaxel Injection

    Science.gov (United States)

    ... with other medications. Paclitaxel injection manufactured with polyoxyethylated castor oil is used to treat ovarian cancer (cancer that ... cancer, and lung cancer. Paclitaxel injection with polyoxyethylated castor oil is also used to treat Kaposi's sarcoma (a ...

  14. Etanercept Injection

    Science.gov (United States)

    ... will be using the prefilled syringe or automatic injection device, tell your doctor if you or the person who will be injecting the medication for you are allergic to rubber or latex.tell your doctor and pharmacist what ...

  15. Cyclosporine Injection

    Science.gov (United States)

    Cyclosporine injection is used with other medications to prevent transplant rejection (attack of the transplanted organ by ... who have received kidney, liver, and heart transplants. Cyclosporine injection should only be used to treat people ...

  16. Estrogen Injection

    Science.gov (United States)

    The estradiol cypionate and estradiol valerate forms of estrogen injection are used to treat hot flushes (hot ... should consider a different treatment. These forms of estrogen injection are also sometimes used to treat the ...

  17. Cefotaxime Injection

    Science.gov (United States)

    Cefotaxime injection is used to treat certain infections caused by bacteria including pneumonia and other lower respiratory ... skin, blood, bone, joint, and urinary tract infections. Cefotaxime injection may also be used before surgery, and ...

  18. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  19. Prevalence and socio-behavioral influence of early childhood caries, ECC, and feeding habits among 6 – 36 months old children in Uganda and Tanzania

    Directory of Open Access Journals (Sweden)

    Masumo Ray

    2012-07-01

    Full Text Available Abstract Background Early childhood caries (ECC is a serious problem that has remained unexplored in sub-Saharan Africa. This study aimed to identify possible socio-behavioral correlates of ECC focusing 6–36 months old children and their caretakers. Methods Cross sectional studies were conducted in a high fluoride rural area, Manyara, Tanzania and a low fluoride urban area, Kampala, Uganda. Totals of 1221 and 816 child - caretaker pairs attending health care facilities for growth monitoring were recruited in Manyara and Kampala, respectively. All caretakers completed face to face interviews at the health care facility. Children underwent oral clinical examination whereby ECC and Enamel hypoplasia were recorded using the dmft (WHO 1997 and the DDE index (FDI 1992. Results The prevalence of ECC was 3.7% in Manyara and 17.6% in Kampala. According to multiple logistic regression analyses, received oral health information from health worker was the strongest determinant of ECC in Manyara, adjusted OR 0.3, 95% CI 0.09 – 0.93. In Kampala, visible plaque, high sugar intake and presence of enamel hypoplasia associated with ECC, adjusted ORs 2.8 (95% CI 1.61- 4.95, 3.0 (95% CI 1.39 – 6.34 and 2.3 (95% CI 1.36 - 3.95. Conclusion Oral health education aimed at caretakers of 6–36 months, including health care workers’ information regarding the detrimental consequences for oral health of frequent sugar consumption and poor oral hygiene is important for prevention of ECC in Tanzania and Uganda.

  20. Ustekinumab Injection

    Science.gov (United States)

    ... Do not inject into an area where the skin is tender, bruised, red, or hard or where you have scars or stretch marks.Your doctor or pharmacist will ... injection.you should know that ustekinumab injection may decrease your ability ... new or changing skin lesions, minor infections (such as open cuts or ...

  1. Ranitidine Injection

    Science.gov (United States)

    Ranitidine injection comes as a solution (liquid) to be mixed with another fluid and injected intravenously (into a vein) over 5 to 20 minutes. Ranitidine may also be injected into a muscle. It is usually given every 6 to 8 hours, but may also be given ...

  2. Experience in using injectable valproic acid (convulex in patients with serial epileptic seizures and status epilepticus at the prehospital stage

    Directory of Open Access Journals (Sweden)

    A. V. Lebedeva

    2012-01-01

    Full Text Available Objective: to evaluate the efficacy of injectable valproate (convulex in patients with serial epileptic seizures and status epilepticus (SE at the prehospital stage.Patients and methods. Thirty-two adult patients, including 17 (53% men and 15 (47% women, were examined. Most patients were aged over 40 years (mean age 54.7±9.4 years. To define the required dose of the drug, the authors estimated the patient's weight that averaged 76.8±1.9 kg, i.e. there was a preponderance of patients who needed convulex, more than 500 mg, to achieve a therapeutic effect.Results. It was impossible to reliably and validly evaluate the type of a seizure as the medical emergency team (MET generally observed the patient with a just evolving seizure and the medical history data were not always valid therefore the type of convulsions and the type of a seizure were evaluated. In most cases, solitary convulsive attacks (tonic and/or clonic convulsions and/or serial seizures were observed in 12 (37.5% and 14 (43.7% patients, respectively; SE was recorded in 6 (8.8% patients. Generalized seizures (without a clear focal onset were prevalent in 24 (75% patients while 8 (25% patients were found to have partial seizures (seizure onset lateralization, a focal onset. According to the pattern of convulsions, seizures may be classified into three types: tonic-clonic, clonic, and tonic in 22 (68.8%, 7 (21.9%, and 3 (9.3% patients, respectively. Analysis of the efficacy of intravenously injectable valproate (convulex in the group of patients with SE and epileptic seizures indicated that complete cessation of seizures could be achieved in 68.8%, their rate decreased in other 9.4% of the patients. Seizures were preserved in 7 (21.8% cases, which required additional administration of drugs. Conclusion. Injectable valproic acid (convulex has a high efficacy and may be preclinically used as the drug of choice to arrest SE and serial seizures caused by both epilepsy and other

  3. R&D Plan for RISMC Industry Application #1: ECCS/LOCA Cladding Acceptance Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Szilard, Ronaldo Henriques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Epiney, Aaron Simon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tu, Lei [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    The Nuclear Regulatory Commission (NRC) is finalizing a rulemaking change that would revise the requirements in 10 CFR 50.46. In the proposed new rulemaking, designated as 10 CFR 50.46c, the NRC proposes a fuel performance-based equivalent cladding reacted (ECR) criterion as a function of cladding hydrogen content before the accident (pre-transient) in order to include the effects of higher burnup on cladding performance as well as to address other technical issues. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee costs as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. The Idaho National Laboratory (INL) has initiated a project, as part of the DOE Light Water Reactor Sustainability Program (LWRS), to develop analytical capabilities to support the industry in the transition to the new rule. This project is called the Industry Application 1 (IA1) within the Risk-Informed Safety Margin Characterization (RISMC) Pathway of LWRS. The general idea behind the initiative is the development of an Integrated Evaluation Model (IEM). The motivation is to develop a multiphysics framework to analyze how uncertainties are propagated across the stream of physical disciplines and data involved, as well as how risks are evaluated in a LOCA safety analysis as regulated under 10 CFR 50.46c. This IEM is called LOTUS which stands for LOCA Toolkit for US, and it represents the LWRS Program’s response to the proposed new rule making. The focus of this report is to complete an R&D plan to describe the demonstration of the LOCA/ECCS RISMC Industry Application # 1 using the advanced RISMC Toolkit and methodologies. This report includes the description and development plan for a RISMC LOCA tool that fully couples advanced MOOSE tools already in development in order to characterize and optimize

  4. Prevalence and characteristics of abuse experiences and depression symptoms among injection drug-using female sex workers in Mexico.

    Science.gov (United States)

    Ulibarri, Monica D; Hiller, Sarah P; Lozada, Remedios; Rangel, M Gudelia; Stockman, Jamila K; Silverman, Jay G; Ojeda, Victoria D

    2013-01-01

    This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs) in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors-ever experiencing forced sex and forced sex in the context of sex work-were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.

  5. Prevalence and Characteristics of Abuse Experiences and Depression Symptoms among Injection Drug-Using Female Sex Workers in Mexico

    Directory of Open Access Journals (Sweden)

    Monica D. Ulibarri

    2013-01-01

    Full Text Available This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors—ever experiencing forced sex and forced sex in the context of sex work—were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.

  6. Trace Code Validation for BWR Spray Cooling Injection and CCFL Condition Based on GÖTA Facility Experiments

    Directory of Open Access Journals (Sweden)

    Stefano Racca

    2012-01-01

    Full Text Available Best estimate codes have been used in the past thirty years for the design, licensing, and safety of NPP. Nevertheless, large efforts are necessary for the qualification and the assessment of such codes. The aim of this work is to study the main phenomena involved in the emergency spray cooling injection in a Swedish-designed BWR. For this purpose, data from the Swedish separate effect test facility GÖTA have been simulated using TRACE version 5.0 Patch 2. Furthermore, uncertainty calculations have been performed with the propagation of input errors method, and the identification of the input parameters that mostly influence the peak cladding temperature has been performed.

  7. Prevention of early childhood caries (ECC) through parental toothbrushing training and fluoride varnish application: a 24-month randomized controlled trial.

    Science.gov (United States)

    Jiang, Emily Ming; Lo, Edward Chin Man; Chu, Chun Hung; Wong, May Chun Mei

    2014-12-01

    To investigate the effectiveness of hands-on training in parental toothbrushing, with or without semi-annual applications of 5% sodium fluoride varnish in preventing ECC. Study was conducted in Hong Kong where water is optimally fluoridated. Children aged 8-23 months were recruited and randomly allocated to one of three groups: Gp 1 - control, one-off oral health education talk to parents; Gp 2 - oral health education talk and parental toothbrushing training, reinforced every 6 months; Gp 3 - semi-annual application of fluoride varnish onto child's teeth in addition to the intervention provided to Gp 2. Clinical examinations of the children and interviews were conducted at baseline and after 24 months to assess the children's dental caries status and toothbrushing behaviour. Out of the 450 child-parent dyads recruited at baseline, 415 (92%) remained after 24 months. At baseline, 2% of the children had non-cavitated enamel caries lesions and the mean dmft score was 0.03 ± 0.24. Most of the children did not have daily parental toothbrushing (65-73%) and self toothbrushing (86-90%). At 24-month follow-up, including both non-cavitated and cavitated carious lesions, the incidences of ECC in Gp 1 to Gp 3 were 11.9%, 11.8%, and 17.5%, respectively (p>0.05); and the mean new dmft scores in Gp 1 to Gp 3 were 0.3, 0.2, and 0.3, respectively (p>0.05). Proportions of parents who practiced parental toothbrushing twice daily were 62.7%, 60.4%, and 65.7% in Gp 1 to Gp 3, respectively (p>0.05). In a water fluoridated area, hands-on training in parental toothbrushing, with or without semi-annual application of 5% sodium fluoride varnish may not have additional effect on preventing ECC in young children with low risk of dental caries compared to provision of oral health education to parents. In a water fluoridated area, provision of individual oral health education to parents may be sufficient for preventing ECC in young children below age 3. Supplemental training in parental

  8. [Animal experiment studies on the effect of intra-articular injections of antiphlogistic-antirheumatic agents on articular cartilage in vivo].

    Science.gov (United States)

    Kalbhen, D A; Schauer, M; Wentsche, B

    1978-01-01

    Animal experiments have shown that weekly intraarticular injections of various antiphlogistic/antirheumatic drugs into the knee joint induce progressive degenerative alterations in joint cartilage. The observed degenerations and destructions are most similar to the pathophysiology of osteoarthrosis in humans. By X-ray and macroscopic techniques the degenerative processes can be studied qualitatively and quantitatively. A decrease of joint space is a sensitive and early indicator of osteoarthrosis and showed that 10 weeks after intraarticular application of Ibuprofen, Phenylbutazone, Oxyphenbutazone, Flufenamic acid, Niflumic acid, Na-salicylate, Clofezone, Bumadizone and Dexamethasone the degenerative alterations in the injected knee joints were more severe than by applications of Chloroquine,D-penicillamine, Salicylamide and Indometacin. The degenerative effect on articular cartilage by the investigated drugs can be explained by their inhibitory potency on anabolic metabolism of connective tissue. The results of our animal experiments lead to the conclusion, that antiinflammatory drugs may also in man induce or accelerate degenerative joint diseases especially after long term treatment with high doses of these drugs.

  9. Effect of sucrose concentration on sucrose-dependent adhesion and glucosyltransferase expression of S. mutans in children with severe early-childhood caries (S-ECC).

    Science.gov (United States)

    Zhao, Wei; Li, Wenqing; Lin, Jiacheng; Chen, Zhuoyu; Yu, Dongsheng

    2014-09-09

    Sucrose, extracellular polysaccharide, and glucosyltransferases (GTFs) are key factors in sucrose-dependent adhesion and play important roles in the process of severe early-childhood caries (S-ECC). However, whether sucrose concentration regulates gtf expression, extracellular polysaccharide synthesis, and sucrose-dependent adhesion is related to the different genotypes of S. mutans isolated from ECC in children and still needs to be investigated. In this study, 52 strains of S. mutans were isolated from children with S-ECC and caries-free (CF) children. Water-insoluble glucan (WIG) synthesis was detected by the anthrone method, adhesion capacity by the turbidimetric method, and expression of gtf by RT-PCR in an in vitro model containing 1%-20% sucrose. The genotypes of S. mutans were analyzed by AP-PCR. The results showed that WIG synthesis, adhesion capacity, and gtf expression increased significantly when the sucrose concentration was from 1% to 10%. WIG synthesis and gtfB as well as gtfC expression of the 1% and 5% groups were significantly lower than those of the 10% and 20% groups (p S. mutans detected from individuals in the S-ECC group exhibited a significant difference in diversity compared with those from CF individuals (p S. mutans, and the 10% sucrose level can be seen as a "turning point" and essential factor for the prevention of S-ECC.

  10. Effects of intra-infralimbic prefrontal cortex injections of cannabidiol in the modulation of emotional behaviors in rats: contribution of 5HT₁A receptors and stressful experiences.

    Science.gov (United States)

    Marinho, A L Z; Vila-Verde, C; Fogaça, M V; Guimarães, F S

    2015-06-01

    The infralimbic (IL) and prelimbic (PL) regions of the prefrontal cortex are involved in behavioral responses observed during defensive reactions. Intra-PL or IL injections of cannabidiol (CBD), a major non-psychotomimetic cannabinoid present in the Cannabis sativa plant, result in opposite behavioral effects in the contextual fear conditioning (CFC) paradigm. The intra-PL effects of CBD are mediated by 5HT1A receptors and depend on previous stressful experiences but the mechanisms and effects of intra-IL CBD injected are unknown. To this aim the present work verified the effects of intra-IL administration of CBD on two animal models of anxiety, the elevated plus maze (EPM) and CFC. We also investigated if these effects were mediated by 5HT1A receptors and depended on previous stressful experience. Male Wistar rats received bilateral microinjections of vehicle, WAY100635 (5HT1A receptor antagonist, 0.37 nmol) and/or CBD (15, 30 or 60 nmol) before being submitted to the behavioral tests. Intra-IL CBD induced anxiolytic and anxiogenic in the EPM and CFC, respectively. To verify if these effects are influenced by the previous stressful experience (footshocks) in the CFC model, we tested the animals in the EPM 24h after a 2-h restraint period. The anxiolytic-like effect of CBD in the EPM disappeared when the animals were previously stressed. Both responses, i.e., anxiolytic and anxiogenic, were prevented by WAY100635, indicating that they involve local 5HT1A-mediated neurotransmission. Together these results indicate that CBD effects in the IL depend on the nature of the animal model, being influenced by previous stressful experiences and mediated by facilitation of 5HT1A receptors-mediated neurotransmission.

  11. Direct injection method for HPLC/MS/MS analysis of acrylamide in aqueous solutions: application to adsorption experiments.

    Science.gov (United States)

    Mnif, Ines; Hurel, Charlotte; Marmier, Nicolas

    2015-05-01

    Polyacrylamides are polymers used in many fields and represent the main source of release of the highly toxic acrylamide in the environment. In this work, a simple, rapid, and sensitive analytical method was developed with HPLC/MS/MS and direct injection for acrylamide analysis in water and adsorption samples. AFNOR standards NF T90-210 and NF T90-220 were used for the analytical method validation and uncertainty estimation. Limit of quantification (LOQ) for acrylamide was 1 μg/L, and accuracy was checked at three acrylamide levels (1, 6, and 10 μg/L). Uncertainties were estimated at 34.2, 22, and 12.4 % for acrylamide concentrations at LOQ, 6 μg/L, and 10 μg/L, respectively. Acrylamide adsorption on clays (kaolinite, illite) and sludge was then studied as a function of pH, time, and acrylamide concentrations. Acrylamide adsorption on kaolinite, illite, and sludge was found to be very weak since adsorption percentages were inferior to 10 %, whatever the pH value and the initial acrylamide concentration. The low affinity of acrylamide for clays and sludge is likely due to its hydrophilic property, small size, and charge neutrality.

  12. No Immunogenicity of IPS Cells in Syngeneic Host Studied by In Vivo Injection and 3D Scaffold Experiments

    Directory of Open Access Journals (Sweden)

    Suganya Thanasegaran

    2013-01-01

    Full Text Available Induced Pluripotent Stem Cells (IPSCs open the great possibility to employ patient’s own tissue to the previously incurable diseases. However these cells can be used in cell therapy only if they are not rejected when transplanted back into the syngeneic host. We found that the injection of iPSCs derived from different ages of mice into syngeneic C57BL/6 mice produced teratoma and was not rejected. Then we cultured iPSCs and myeloid differentiated iPSCs in three-dimensional porous scaffold and transplanted to C57BL/6 mice and BALB/C mice. After transplantation, we could observe the cell density inside the scaffold increased rapidly in syngeneic mice compared to the allogeneic mice indicating the favorable conditions supporting the growth of iPSCs in vivo. Unlike the allogeneic counterpart, we could not observe few infiltrating T cells inside the scaffold of syngeneic mice. These results contribute to the optimistic view of iPSCs for regenerative medicine in near future.

  13. Low-Profile Dual-Wideband MIMO Antenna with Low ECC for LTE and Wi-Fi Applications

    Directory of Open Access Journals (Sweden)

    Gye-Taek Jeong

    2014-01-01

    Full Text Available This paper presents a low-profile dual-wideband multiple input multiple output (MIMO antenna with low envelop correlation coefficient (ECC for long-term evolution (LTE and wireless fidelity (Wi-Fi applications. The antenna covers LTE band 7 and Wi-Fi as well as wireless broadband (Wibro and Worldwide Interoperability for Microwave Access (WiMax (except for the 3.5-GHz band. To aid with integration of a practical mobile terminal, the MIMO antenna elements are placed at appropriate locations by analyzing the surface current distribution and without using any additional isolation techniques. The measured bandwidths with reflection coefficients of 20 dB in the operating frequency ranges of both LTE band 7 and Wi-Fi. Additionally, the calculated ECC is in the range 0.005<ρ<0.025, which is considerably lower than the ρ<0.5 required for MIMO applications. The measured radiation patterns are appropriate for mobile terminals, and omnidirectional radiation patterns are obtained.

  14. AN ANALYSIS OF STUDENTS’ SPEAKING ABILITY IN ENGLISH CONVERSATION CLUB (ECC PROGRAM AT THE 3rd SEMESTER

    Directory of Open Access Journals (Sweden)

    M. Fadhly Farhy Abbas

    2017-07-01

    Full Text Available This research is based on students’ speaking ability who had followed the EnglishConversation Club (ECC program especially for the third semester of English Department. Thepurpose of this study was to analyze the students’ speaking ability at the 3rd semester in the EnglishConversation Club FKIP UNILAK Pekanbaru. The type of the research was mixed method in typeof explanatory design. The number of participant was 53 students. The researcher used twoinstruments, those were test and interview. In analyzing the data, it used in descriptive statistics.The result of the analysis showed that the average score of 3rd semester students’ speaking abilitywas 45.42. It can be concluded that the students’ speaking ability was categorized into failed . Thescore of Standard Deviation was 7.02, Variance was 49.30, and Range was 36 points . It meansthat the students’ speaking ability was homogeneous. According to the Z-Score, it can be seen that49.06% students’ ability was higher than average and 50.94% students ability was below theaverage. In conclusion, the students’ ability in learning speaking English was failed, it had beenaffected by some factors, those were lack of vocabulary, grammar and motivation. It was supportedby the interview, eventhough the students’ perception to English Conversation Club (ECCprogram was positive, but in fact, the students’ frequency to speak English was seldom, they wereless practice speaking English everyday.Keywords : Speaking , English Conversation Club (ECC

  15. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure...... build-up was evaluated indirectly from the changes in the flow rate between subcutaneous injections and air injections. This method enabled the tissue counter pressure to be evaluated without a formal clinical study approval. The measurements were coupled to a model for the pressure evolution...

  16. Design of ECC system based on System Generator%基于System Generator的ECC加解密系统设计

    Institute of Scientific and Technical Information of China (English)

    肖雪芳; 苏航; 雷国伟

    2012-01-01

    Based on several key algorithms of ECC (Elliptic Curve Cryptosystem), each module of the algorithms was designed via Modelsim tool. Then the source codes of each module were generated into its counterpart of ECC system by System Generator, and the modules were grouped into ECC system. Finally, the system was simulated and verified by experimental results.%根据椭圆曲线密码体制的几种关键算法,采用Modelsim仿真工具设计相应的算法模块.然后将各模块代码通过System Generator生成对应的系统模块,再将这些模块搭建成完整的ECC系统.最后对整个ECC系统进行仿真,实验数据进一步验证了该设计的正确性.

  17. A qualitative study of experiences with and perceptions regarding long-acting injectable antipsychotics: Part I-patient perspectives.

    Science.gov (United States)

    Iyer, Srividya; Banks, Nicola; Roy, Marc-André; Tibbo, Phil; Williams, Richard; Manchanda, Rahul; Chue, Pierre; Malla, Ashok

    2013-05-01

    Objectif : Malgré le problème largement reconnu de la mauvaise observance des antipsychotiques (AP), les injectables à action prolongée (IAP) qui pourraient améliorer l’observance sont sous-utilisés au Canada. Les attitudes à l’égard des IAP chez les patients et les psychiatres peuvent contribuer à cette sous-utilisation. Notre objectif était d’enquêter sur les perceptions et les attitudes des patients à l’égard des IAP au Canada. Méthode : Des groupes de discussion ont été formés de 34 patients ayant reçu un diagnostic de psychose du spectre de la schizophrénie dans 4 provinces canadiennes. Les groupes de discussion portaient sur les expériences avec les AP IAP et les attitudes à leur égard. Les séances ont fait l’objet d’un enregistrement sonore et ont été transcrites textuellement, et ces transcriptions ont été codées à l’aide d’une combinaison de méthodes déductives et inductives. Résultats : Quatre thèmes se sont dégagés : conscience et connaissance des IAP; perceptions des IAP; considérations concernant le coût et la commodité; et les questions liées au contexte coercitif dans lequel les IAP sont souvent prescrits. Neuf patients n’avaient jamais entendu parler des IAP, et d’autres ont déclaré ne pas avoir compris lorsqu’on a discuté avec eux des IAP. Les patients avaient habituellement entendu parler des IAP dans un contexte soit de coercition, soit de non-observance des médicaments. Les patients avaient des perceptions positives et négatives à l’égard des IAP. Les perceptions positives étaient axées sur la prévention de la rechute et l’effort réduit pour maintenir l’observance, et les perceptions négatives portaient sur les coûts financiers et la complication des rendez-vous pour recevoir les injections. Conclusion : Afin d’accroître l’utilisation des IAP, il faut aborder certaines questions, notamment l’insuffisance de l’information donnée aux patients, l

  18. Low mortality but increasing incidence of Staphylococcus aureus endocarditis in people who inject drugs: Experience from a Swedish referral hospital.

    Science.gov (United States)

    Asgeirsson, Hilmir; Thalme, Anders; Weiland, Ola

    2016-12-01

    Staphylococcus aureus is a leading cause of infective endocarditis in people who inject drugs (PWID). The management of S aureus endocarditis (SAE) in PWID can be problematic. The objective of this retrospective observational study was to assess the epidemiology, clinical characteristics, and mortality of S aureus endocarditis (SAE) in PWID in Stockholm, Sweden.The Department of Infectious Diseases at the Karolinska University Hospital serves as a regional referral center for drug users with severe infections. Patients with active intravenous drug use treated for SAE at the department between January 2004 and December 2013 were retrospectively identified. Clinical and microbiological data were obtained from medical records and the diagnosis verified according to the modified Duke criteria.In total, 120 SAE episodes related to intravenous drug use were identified. Its incidence in Stockholm was 0.76/100,000 adult person-years for the entire period, increasing from 0.52/100,000 person-years in 2004 to 2008 to 0.99 in 2009 to 2013 (P = 0.02). The SAE incidence among PWID specifically was 249 (range 153-649) /100,000 person-years. Forty-two (35%) episodes were left-sided, and multiple valves were involved in 26 (22%). Cardiac valve surgery was performed in 10 (8%) episodes, all left-sided. The in-hospital and 1-year mortality rates were 2.5% (3 deaths) and 8.0% (9 deaths), respectively.We noted a high and increasing incidence over time of SAE related to intravenous drug use in Stockholm. The increased incidence partly reflects a rising number of PWID during the study period. The low mortality noted, despite a substantial proportion with left-sided endocarditis, probably in part reflects the quality of care obtained at a large and specialized referral center for drug users with severe infections.

  19. Effect of Sucrose Concentration on Sucrose-Dependent Adhesion and Glucosyltransferase Expression of S. mutans in Children with Severe Early-Childhood Caries (S-ECC

    Directory of Open Access Journals (Sweden)

    Wei Zhao

    2014-09-01

    Full Text Available Sucrose, extracellular polysaccharide, and glucosyltransferases (GTFs are key factors in sucrose-dependent adhesion and play important roles in the process of severe early-childhood caries (S-ECC. However, whether sucrose concentration regulates gtf expression, extracellular polysaccharide synthesis, and sucrose-dependent adhesion is related to the different genotypes of S. mutans isolated from ECC in children and still needs to be investigated. In this study, 52 strains of S. mutans were isolated from children with S-ECC and caries-free (CF children. Water-insoluble glucan (WIG synthesis was detected by the anthrone method, adhesion capacity by the turbidimetric method, and expression of gtf by RT-PCR in an in vitro model containing 1%–20% sucrose. The genotypes of S. mutans were analyzed by AP-PCR. The results showed that WIG synthesis, adhesion capacity, and gtf expression increased significantly when the sucrose concentration was from 1% to 10%. WIG synthesis and gtfB as well as gtfC expression of the 1% and 5% groups were significantly lower than those of the 10% and 20% groups (p < 0.05. There were no significant differences between the 10% and 20% groups. The fingerprints of S. mutans detected from individuals in the S-ECC group exhibited a significant difference in diversity compared with those from CF individuals (p < 0.05. Further, the expression of gtfB and gtfC in the S-ECC group was significantly different among the 1- to 5-genotype groups (p < 0.05. It can be concluded that sucrose-dependent adhesion might be related to the diversity of genotypes of S. mutans, and the 10% sucrose level can be seen as a “turning point” and essential factor for the prevention of S-ECC.

  20. Light scattering experiments on aqueous solutions of selected cellulose ethers: contribution to the study of polymer-mineral interactions in a new injectable biomaterial

    Science.gov (United States)

    Bohic, Sylvain; Weiss, Pierre; Roger, Philippe; Daculsi, Guy

    2001-01-01

    Hydroxypropylmethylcellulose (HPMC) is used as a ligand for a bioactive calcium phosphate ceramic (the filler) in a ready-to-use injectable sterilized biomaterial for bone and dental surgery. Light scattering experiments were usually used to study high water-soluble polymers and to determine the basic macromolecular parameters. In order to gain a deeper understanding of polymer/mineral interactions in this type of material, we have investigated the effect of divalent and trivalent ions (Ca2+, PO43−) and steam sterilization on dilute solutions of HPMC and HEC. The sterilization process may cause some degradation of HEC taking into account its high molecular weight and some rigidity of the polymer chain. Moreover, in the case of HPMC, the changes in the conformations rather than degradation process are supposed. These effects of degradation and flocculation are strengthened in alkaline medium. Experimental data suggested the formation of chelate complexes between Ca2+ and HPMC which improve its affinity to the mineral blend and consolidate the injectable biomaterial even in the case of its hydration by biological fluid. PMID:15348303

  1. Design Experience and Skills of Large Injection Mold%大型注塑模具设计经验与技巧

    Institute of Scientific and Technical Information of China (English)

    张维合

    2012-01-01

    Design experience and skills of large injection mold were introduced by using the refrigerator transparent store content ark injection mould as an example. The hydraulic cylinder for lateral oblique core-pulling, the fission style inclined top for inside-oblique core pulling, the pressure gas and push block for plastic parts demolding were adopted. Its side core-pulling mechanism was complex, and cooling system design was reasonable. Production practice proved that the forming period and plastic parts quality could meet the requirements of customer.%以某电冰箱透明储物柜注塑模具为例,简述了大型注塑模具的设计经验与技巧.模具采用液压油缸进行外侧斜向抽芯,采用分体式斜顶进行内侧斜向抽芯,采用气压和推块联合推出塑件.模具侧向抽芯机构复杂,冷却系统设计合理.实际运行表明,成型周期和塑件质量符合客户要求.

  2. Injection MD

    CERN Document Server

    Bartmann, W; Bracco, C; Drosdal, L; Gianfelice, E; Goddard, B; Kain, V; Papaphilippou, Y; Vanbavinckhove, G

    2012-01-01

    This note summarizes the results obtained at injection during the 2nd MD block and the floating MD block in July. Highlights are presented for injection in the LHC with the Q20 SPS optics, influence of the supercycle and injection with 25 ns bunch spacing. Beams were successfully injected into the LHC using the Q20 optics [1, 3]. Small corrections were needed to steer the beam in the transfer lines. Dispersion measurements were conducted for both beams. The horizontal normalized dispersion in TI2 was a factor 2 smaller for Q20 with respect to Q26, for TI8 on the other hand the opposite was observed. The results for injection loss dependency on super cycle composition show only a small increase in losses for beam 2. The losses observed must therefore mainly come from other sources such as shot-by-shot stability or quality of scraping. For the injection with 25 ns bunch spacing bunches were injected for both beams. For B1 up to the maximum of 288 bunches. For B2 on the other only up to 144 bunches were injected...

  3. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure...... build-up was evaluated indirectly from the changes in the flow rate between subcutaneous injections and air injections. This method enabled the tissue counter pressure to be evaluated without a formal clinical study approval. The measurements were coupled to a model for the pressure evolution...... in subcutaneous tissue, based on mass conservation and flow in a porous medium. From the measurements the flow permeability and bulk modulus of the tissue were determined. In the adipose tissue the drug forms a bolus from where it is absorbed by the blood capillaries. The spatial distribution of the injected...

  4. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

    Science.gov (United States)

    Arpinar, V E; Hamamura, M J; Degirmenci, E; Muftuler, L T

    2012-07-07

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique, electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently, the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as IEC601. This protocol limits patient auxiliary currents to 100 µA for low frequencies. However, published MREIT studies have utilized currents 10-400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200 µA total injected current and tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul (1998 Elektrik 6 215-25) with Tikhonov regularization and the harmonic B(Z) proposed by Oh et al (2003 Magn. Reason. Med. 50 875-8). The reconstruction techniques were tested at both 200 µA and 5 mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200 µA total injected current into a cylindrical phantom generates only 14.7 µA current in imaging slice. Similarly, 5 mA total injected current results in 367 µA in imaging slice. Total

  5. Corticosteroid injections, eccentric decline squat training and heavy slow resistance training in patellar tendinopathy

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Kovanen, V.; Aagaard, P.

    2009-01-01

    A randomized-controlled single-blind trial was conducted to investigate the clinical, structural and functional effects of peritendinous corticosteroid injections (CORT), eccentric decline squat training (ECC) and heavy slow resistance training (HSR) in patellar tendinopathy. Thirty-nine male...... patients were randomized to CORT, ECC or HSR for 12 weeks. We assessed function and symptoms (VISA-p questionnaire), tendon pain during activity (VAS), treatment satisfaction, tendon swelling, tendon vascularization, tendon mechanical properties and collagen crosslink properties. Assessments were made at 0...... weeks, 12 weeks and at follow-up (half-year). All groups improved in VISA-p and VAS from 0 to 12 weeks (P tendon swelling decreased (-13 +/- 9% and -12 +/- 13%, P

  6. Mepolizumab Injection

    Science.gov (United States)

    ... or do not go away: pain, redness, swelling, warmth, burning, or itching in the place mepolizumab was injected headache dry and itchy skin with or without red, scaly rashes back pain muscle spasms Some side ...

  7. Metoclopramide Injection

    Science.gov (United States)

    ... and feeling of fullness that lasts long after meals. Metoclopramide injection is also used to prevent nausea ... tranylcypromine (Parnate); narcotic medications for pain; sedatives; sleeping pills; tetracycline (Bristacycline, Sumycin); tranquilizers. Your doctor may need ...

  8. Alemtuzumab Injection

    Science.gov (United States)

    Alemtuzumab injection is used to treat B-cell chronic lymphocytic leukemia (a slowly developing cancer in which ... of white blood cell accumulate in the body). Alemtuzumab is in a class of medications called monoclonal ...

  9. Ferumoxytol Injection

    Science.gov (United States)

    Ferumoxytol injection is used to treat iron-deficiency anemia (a lower than normal number of red blood ... pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking or ...

  10. Fludarabine Injection

    Science.gov (United States)

    Fludarabine injection is used to treat chronic lymphocytic leukemia (CLL; a type of cancer of the white ... a reliable method of birth control to prevent pregnancy during this time. Talk to your doctor for ...

  11. Insulin Injection

    Science.gov (United States)

    ... or buttocks. Do not inject insulin into muscles, scars, or moles. Use a different site for each ... you are using insulin.Alcohol may cause a decrease in blood sugar. Ask your doctor about the ...

  12. Tigecycline Injection

    Science.gov (United States)

    ... in a person who was not in the hospital), skin infections, and infections of the abdomen (area between the ... that developed in people who were in a hospital or foot infections in people who have diabetes. Tigecycline injection is ...

  13. Golimumab Injection

    Science.gov (United States)

    Golimumab injection is used alone or with other medications to relieve the symptoms of certain autoimmune disorders ( ... did not help or could not be tolerated. Golimumab is in a class of medications called tumor ...

  14. Albiglutide Injection

    Science.gov (United States)

    ... will develop tumors of the thyroid gland, including medullary thyroid carcinoma (MTC; a type of thyroid cancer). ... symptoms or those listed in the IMPORTANT WARNING section, stop using albiglutide injection and call your doctor ...

  15. Dexamethasone Injection

    Science.gov (United States)

    ... body tissues,) gastrointestinal disease, and certain types of arthritis. Dexamethasone injection is also used for diagnostic testing. ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  16. Hydrocortisone Injection

    Science.gov (United States)

    ... own organs), gastrointestinal disease, and certain types of arthritis. Hydrocortisone injection is also used to treat certain ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  17. Methylprednisolone Injection

    Science.gov (United States)

    ... own organs), gastrointestinal disease, and certain types of arthritis. Methylprednisolone injection is also used to treat certain ... effects.tell your doctor if you have a fungal infection (other than on your skin or nails). ...

  18. Glatiramer Injection

    Science.gov (United States)

    ... To inject glatiramer, follow these steps: Remove one blister pack from the carton of glatiramer syringes and place ... paper label and remove the syringe from the blister pack. Check your prefilled syringe to be sure it ...

  19. Dexrazoxane Injection

    Science.gov (United States)

    ... that are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are ...

  20. Evolocumab Injection

    Science.gov (United States)

    ... autoinjector in hot water, microwave, or place in sunlight.Before you use evolocumab injection, look at the ... chills pain or burning during urination muscle or back pain dizziness stomach pain Some side effects can be ...

  1. Cidofovir Injection

    Science.gov (United States)

    Cidofovir injection is used along with another medication (probenecid) to treat cytomegaloviral retinitis (CMV retinitis) in people with acquired immunodeficiency syndrome (AIDS). Cidofovir is in a class of medications called antivirals. ...

  2. Brivaracetam Injection

    Science.gov (United States)

    ... older. Brivaracetam in a class of medications called anticonvulsants. It works by decreasing abnormal electrical activity in ... older (about 1 in 500 people) who took anticonvulsants like brivaracetam injection to treat various conditions during ...

  3. Diphenhydramine Injection

    Science.gov (United States)

    ... not to use diphenhydramine injection if you are breastfeeding because of the risk of harm to infants.tell your doctor if you have or have ever had asthma or other types of lung disease; glaucoma (a ...

  4. Cefazolin Injection

    Science.gov (United States)

    ... valve, respiratory tract (including pneumonia), biliary tract, and urinary tract infections. Cefazolin injection also may be used before, during, ... to learn about take-back programs in your community. See the FDA's Safe Disposal of Medicines website ( ...

  5. Ceftazidime Injection

    Science.gov (United States)

    ... skin, blood, bone, joint, female genital tract, and urinary tract infections. Ceftazidime injection is in a class of medications ... to learn about take-back programs in your community. See the FDA's Safe Disposal of Medicines website ( ...

  6. Fluconazole Injection

    Science.gov (United States)

    ... and fungal infections of the eye, prostate (a male reproductive organ), skin and nails. Fluconazole injection is ... Motrin, others) and naproxen (Aleve, Anaprox, Naprelan); oral contraceptives (birth control pills); oral medication for diabetes such ...

  7. Moxifloxacin Injection

    Science.gov (United States)

    ... available.Moxifloxacin injection is in a class of antibiotics called fluoroquinolones. It works by killing the bacteria that cause ... you are allergic to moxifloxacin, other quinolone or fluoroquinolone antibiotics such as ciprofloxacin (Cipro), gatifloxacin (Tequin) (not available ...

  8. Levofloxacin Injection

    Science.gov (United States)

    ... available. Levofloxacin injection is in a class of antibiotics called fluoroquinolones. It works by killing bacteria that cause infections. ... severe reaction to levofloxacin; any other quinolone or fluoroquinolone antibiotic such as ciprofloxacin (Cipro), gatifloxacin (Tequin) (not available ...

  9. Ciprofloxacin Injection

    Science.gov (United States)

    ... available. Ciprofloxacin injection is in a class of antibiotics called fluoroquinolones. It works by killing bacteria that cause infections. ... reaction to ciprofloxacin or any other quinolone or fluoroquinolone antibiotic such as gatifloxacin (Tequin) (not available in the ...

  10. Alirocumab Injection

    Science.gov (United States)

    ... further decrease the amount of low-density lipoprotein (LDL) cholesterol ('bad cholesterol') in the blood. Alirocumab injection is ... antibodies. It works by blocking the production of LDL cholesterol in the body to decrease the amount of ...

  11. Chloramphenicol Injection

    Science.gov (United States)

    ... an arm or leg sudden changes in vision pain with eye movement Chloramphenicol injection may cause a condition called gray syndrome in premature and newborn infants. There have also been reports of gray ...

  12. Non-double-couple mechanisms of microearthquakes induced during the 2000 injection experiment at the KTB site, Germany: A result of tensile faulting or anisotropy of a rock?

    Science.gov (United States)

    Vavryčuk, Václav; Bohnhoff, Marco; Jechumtálová, Zuzana; Kolář, Petr; Šílený, Jan

    2008-08-01

    Moment tensors of microearthquakes induced during the 2000 injection experiment at the KTB deep drilling borehole at a depth level of 5.4 km are studied. A family of 37 most reliable moment tensors contains significant non-double-couple (non-DC) components. The DC is on average 60% and the non-DC is 40%. Fault plane solutions computed from the DC part show preferred strike-slip mechanisms with small normal or reverse components. A predominant azimuth of P and T axes is in the range of N320°-340°E and of N230°-250°E, respectively. The non-DC components contain both the isotropic (ISO) and compensated linear vector dipole (CLVD) components. The mean value of ISO is 1.5%, the mean value of CLVD is - 5.7%. The predominantly negative CLVD components are inconsistent with the concept of the non-DC mechanisms as a result of tensile faulting due to fluid injection into the rock. The main origin of the non-DC components is probably anisotropy in the focal area. The other origins are errors produced by mismodelling of the medium when calculating the Green functions, and numerical errors produced by noise and limitations of input data. Adopting four alternative models of anisotropy obtained by other seismic measurements at the KTB, we have employed the non-DC components for estimating an optimum orientation of anisotropy in the focal area. The optimum orientation of the symmetry plane of anisotropy is nearly vertical with a strike of N335°-340°E. This strike coincides well with the strike of 330° typical for many major lithological units and faults and with the orientation of the transversely isotropic model inferred by other authors. After removing the anisotropy effects from the moment tensors by calculating the source tensors, the distribution of ISO is significantly narrowed. This indicates predominantly shear, but not tensile faulting.

  13. Model experiment on change of seismic properties of a fracture caused by injecting/draining water; Chusui/haisui ni yoru kison kiretsu no dansei denpa tokusei no henka ni kansuru model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T.; Koizumi, T.; Sassa, K. [Kyoto University, Kyoto (Japan). Faculty of Engineering

    1997-05-27

    Effect of water injection/draining on elastic waves penetrating through cracks is examined by measuring elastic waves before, during, and after the injection/draining of water into/from cracks in presence in granite. Two blocks of rock, with their crack-containing surfaces in contact with each other, are placed in a vessel, and water injection/draining is done through a hole on a vessel bottom side so that water will penetrate into the cracks. When the blocks are dry, there is almost no contact between the cracks, and so no crack penetrating waves are observed. Crack penetrating waves are produced when water is injected, and the position of the receiver sensing the penetrating waves changes as the water level rises. When the water level is lowered from the high water level, the waveform changes again as the level changes. The change in waveform is not so remarkable, however, as that observed during water injection thanks to the water residual in the cracks. It is now inferred that crack investigation is more effective when it is carried out with water being injected into dry cracks. The difference produced between the dry state and wet state when water is injected into dry cracks is used to detect the presence of cracks in this experiment, and this may be applied also to the investigation of cracks in the shallow part of the ground. 4 refs., 11 figs.

  14. Sarilumab Injection

    Science.gov (United States)

    ... the needle. Do not try to warm the medication by heating it in a microwave, placing it in warm water or in direct sunlight, or through any other method.Before injecting, check the prefilled syringe to be sure that the expiration date printed on the package has not passed. Look ...

  15. Enfuvirtide Injection

    Science.gov (United States)

    ... inject enfuvirtide into any skin that has a tattoo, scar, bruise, mole, a burn site, or has ... Enfuvirtide may cause side effects. Tell your doctor if any of these symptoms are severe or do not go away: itching, swelling, pain, tingling, discomfort, ...

  16. Lanreotide Injection

    Science.gov (United States)

    Lanreotide injection is used to treat people with acromegaly (condition in which the body produces too much growth hormone, causing enlargement of the hands, feet, and facial features; joint pain; and other symptoms) who have not successfully, or cannot be treated ...

  17. Assessment of wall friction model in multi-dimensional component of MARS with air–water cross flow experiment

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jin-Hwa [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Choi, Chi-Jin [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Cho, Hyoung-Kyu, E-mail: chohk@snu.ac.kr [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Park, Goon-Cherl [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of)

    2017-02-15

    Recently, high precision and high accuracy analysis on multi-dimensional thermal hydraulic phenomena in a nuclear power plant has been considered as state-of-the-art issues. System analysis code, MARS, also adopted a multi-dimensional module to simulate them more accurately. Even though it was applied to represent the multi-dimensional phenomena, but implemented models and correlations in that are one-dimensional empirical ones based on one-dimensional pipe experimental results. Prior to the application of the multi-dimensional simulation tools, however, the constitutive models for a two-phase flow need to be carefully validated, such as the wall friction model. Especially, in a Direct Vessel Injection (DVI) system, the injected emergency core coolant (ECC) on the upper part of the downcomer interacts with the lateral steam flow during the reflood phase in the Large-Break Loss-Of-Coolant-Accident (LBLOCA). The interaction between the falling film and lateral steam flow induces a multi-dimensional two-phase flow. The prediction of ECC flow behavior plays a key role in determining the amount of coolant that can be used as core cooling. Therefore, the wall friction model which is implemented to simulate the multi-dimensional phenomena should be assessed by multidimensional experimental results. In this paper, the air–water cross film flow experiments simulating the multi-dimensional phenomenon in upper part of downcomer as a conceptual problem will be introduced. The two-dimensional local liquid film velocity and thickness data were used as benchmark data for code assessment. And then the previous wall friction model of the MARS-MultiD in the annular flow regime was modified. As a result, the modified MARS-MultiD produced improved calculation result than previous one.

  18. Subcutaneous (SQ) injections

    Science.gov (United States)

    SQ injections; Sub-Q injections; Diabetes subcutaneous injection; Insulin subcutaneous injection ... NIH. Giving a subcutaneous injection . Rockville, MD. National ... of Health and Human Services NIH publications; 2015. Available ...

  19. Industry Application ECCS / LOCA Integrated Cladding/Emergency Core Cooling System Performance: Demonstration of LOTUS-Baseline Coupled Analysis of the South Texas Plant Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Szilard, Ronaldo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Epiney, Aaron [Idaho National Lab. (INL), Idaho Falls, ID (United States); Parisi, Carlo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Vaghetto, Rodolfo [Texas A & M Univ., College Station, TX (United States); Vanni, Alessandro [Texas A & M Univ., College Station, TX (United States); Neptune, Kaleb [Texas A & M Univ., College Station, TX (United States)

    2017-06-01

    Under the auspices of the DOE LWRS Program RISMC Industry Application ECCS/LOCA, INL has engaged staff from both South Texas Project (STP) and the Texas A&M University (TAMU) to produce a generic pressurized water reactor (PWR) model including reactor core, clad/fuel design and systems thermal hydraulics based on the South Texas Project (STP) nuclear power plant, a 4-Loop Westinghouse PWR. A RISMC toolkit, named LOCA Toolkit for the U.S. (LOTUS), has been developed for use in this generic PWR plant model to assess safety margins for the proposed NRC 10 CFR 50.46c rule, Emergency Core Cooling System (ECCS) performance during LOCA. This demonstration includes coupled analysis of core design, fuel design, thermalhydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results. Within this context, a multi-physics best estimate plus uncertainty (MPBEPU) methodology framework is proposed.

  20. Risk-Informed Margin Management (RIMM) Industry Applications IA1 - Integrated Cladding ECCS/LOCA Performance Analysis - Problem Statement

    Energy Technology Data Exchange (ETDEWEB)

    Szilard, Ronaldo Henriques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Youngblood, Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Frepoli, Cesare [Idaho National Lab. (INL), Idaho Falls, ID (United States); Yurko, Joseph P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swindlehurst, Gregg [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Smith, Curtis L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-04-01

    The U. S. NRC is currently proposing rulemaking designated as “10 CFR 50.46c” to revise the LOCA/ECCS acceptance criteria to include the effects of higher burnup on cladding performance as well as to address some other issues. The NRC is also currently resolving the public comments with the final rule expected to be issued in the summer of 2016. The impact of the final 50.46c rule on the industry will involve updating of fuel vendor LOCA evaluation models, NRC review and approval, and licensee submittal of new LOCA evaluations or reanalyses and associated technical specification revisions for NRC review and approval. The rule implementation process, both industry and NRC activities, is expected to take 5-10 years following the rule effective date. The need to use advanced cladding designs is expected. A loss of operational margin will result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin.

  1. [Pre- and postoperative corneal topography after combined single suture and running suture in ECCE. An analysis using the video keratoscope].

    Science.gov (United States)

    Schickel, B; Holschbach, A; Strobel, J

    1993-12-01

    In a prospective study with 45 patients undergoing extracapsular cataract extraction (ECCE) with implantation of posterior chamber lens, curvature measurements of the cornea by means of computerized videokeratoscope were taken postoperatively. Analysis of the corneal shape on color-coded topographic maps of astigmatism showed an hourglass-shaped formation in all patients with a main axis in the sense of general astigmatism. Within a 3-mm zone (optical zone) the steepest meridian in all eyes was 96.1 +/- 13.3 degrees with an astigmatism of +4.4 +/- 2.1 D (1st postoperative day). Postoperatively we found that 35.6% of the patients examined had irregular astigmatism that could not be corroborated by the readings from the Javal ophthalmometer. An irregular astigmatism, corneal topographic analysis reveals regions peripheral to the center with a peak corneal refractive power of +43.8 +/- 1.4 D. In contrast to the conventional methods (for example, Javal ophthalmometer, autokeratometer), computerized videokeratoscope analysis provides additional and useful information on the corneal topography after intraocular operations.

  2. Experiments on current-driven three-dimensional ion sound turbulence. I - Return-current limited electron beam injection. II - Wave dynamics

    Science.gov (United States)

    Stenzel, R. L.

    1978-01-01

    Pulsed electron beam injection into a weakly collisional magnetized background plasma is investigated experimentally; properties of the electron beam and background plasma, as well as the low-frequency instabilities and wave dynamics, are discussed. The current of the injected beam closes via a field-aligned return current of background electrons. Through study of the frequency and wavenumber distribution, together with the electron distribution function, the low-frequency instabilities associated with the pulsed injection are identified as ion acoustic waves driven unstable by the return current. The frequency cut-off of the instabilities predicted from renormalized plasma turbulence theory, has been verified experimentally.

  3. Avelumab Injection

    Science.gov (United States)

    ... experience certain side effects. Tell your doctor or nurse immediately if you experience any of the following symptoms during the infusion: chills or shaking, hives, fever, flushing, back pain, shortness of breath, wheezing, or stomach pain.Your ...

  4. Initial clinical experience with near-infrared spectroscopy in assessing cerebral tissue oxygen saturation in cerebral vasospasm before and after intra-arterial verapamil injection.

    Science.gov (United States)

    Meng, Lingzhong; Settecase, Fabio; Xiao, Jifang; Yu, Zhaoxia; Flexman, Alana M; Higashida, Randall T

    2016-04-01

    Cerebral vasospasm is a devastating complication after subarachnoid hemorrhage. The use of cerebral tissue oxygen saturation (SctO2) to non-invasively assess changes in cerebral tissue perfusion induced by intra-arterial (IA) verapamil treatment has not been described to our knowledge. A total of 21 consecutive post-craniotomy patients scheduled for possible IA verapamil treatment of cerebral vasospasm were recruited. The effect of IA verapamil injection on SctO2 being continuously monitored on both the left and right forehead was investigated. Comparisons between changes in SctO2 monitored on the ipsilateral and contralateral forehead in relationship to the side of internal carotid artery (ICA) injection were performed. A total of 47 IA verapamil injections (15 left ICA, 18 right ICA, and 14 vertebral artery injections) during 18 neurointerventional procedures in 13 patients were analyzed. IA verapamil administration led to both increases and decreases in SctO2. Changes in SctO2 ipsilateral to the ICA injection side were more pronounced (p=0.02 and 0.07 for left and right ICA injections, respectively) and favored compared to contralateral SctO2 changes. We were unable to obtain reliable measurements on the side ipsilateral to the craniotomy during four procedures in three patients, presumably secondary to pneumocephalus. The local cerebral vasodilating effect of IA verapamil injection is suggested by the differential changes in SctO2 ipsilateral and contralateral to the ICA injection side. The inconsistent changes in SctO2 and the limitations of applying cerebral oximetry in this patient population needs to be recognized.

  5. Observation of abrupt changes associated with air injection into the ground by the time lapse experiment using an ultra-stable seismic source

    Science.gov (United States)

    Kasahara, J.; Ito, S.; Fujiwara, T.; Hasada, Y.; Tsuruga, K.; Ikuta, R.; Fujii, N.; Yamaoka, K.; Nishigami, K.; Ito, K.

    2011-12-01

    To prove the temporal change of seismic waves due to the injection of air into the ground, we carried out a field test near the Nojima Earthquake Fault in Awaji Island using an ultra-stable and conscious seismic source and a seismic array. The newly built seismic ACROSS was installed horizontally as the rotational axis of weight-mass was horizontal. We used 10-35Hz. We injected 80 tons air into the Okasa formation at 100 m depth. We analyzed 31 3-component seismometer records and one 3-component borehole seismometer record at 800m depth. Applying source signature deoconvolution to the filed records, we obtained the transfer function between the source and each receiver. All transfer function associated with injection revealed very large changes of waveforms immediately after the beginning of injection of air at some sites. However the station #7 at 100m from the injection well showed extremely large change at 1 day after the injection. The delay times for appearance of waveform change vary place to place and the differential waveform characteristics for each station are quite different one by one. We explain possible causes of waveform change.

  6. Phacoemulsification with posterior chamber intraocular lens versus extracapsular cataract extraction (ECCE) with posterior chamber intraocular lens for age-related cataract.

    Science.gov (United States)

    de Silva, Samantha R; Riaz, Yasmin; Evans, Jennifer R

    2014-01-29

    Age-related cataract is one of the leading causes of blindness worldwide. Therefore, it is important to establish the most effective surgical technique for cataract surgery. The aim of this review is to examine the effects of two types of cataract surgery for age-related cataract: phacoemulsification and extracapsular cataract extraction (ECCE). We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 4), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to May 2013), EMBASE (January 1980 to May 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to May 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1970 to May 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 May 2013. We included randomised controlled trials of phacoemulsification compared to ECCE for age-related cataract. Two authors independently selected and assessed all studies. We defined two primary outcomes: 'good functional vision' (presenting visual acuity of 6/12 or better) and 'poor visual outcome' (best corrected visual acuity of less than 6/60) at three and 12 months after surgery. We also collected data on intra and postoperative complications, and the cost of the procedures. We included 11 trials in this review with a total of 1228 participants, ranging from age 45 to 94. The studies were generally at unclear risk of bias due to poorly reported trial methods. No study reported presenting visual acuity, so we report both uncorrected (UCVA) and best corrected visual acuity (BCVA

  7. Prevalence of candida albicans in dental plaque and caries lesion of early childhood caries (ECC) according to sampling site

    Science.gov (United States)

    Ghasempour, Maryam; Sefidgar, Seyed Ali Asghar; Eyzadian, Haniyeh; Gharakhani, Samaneh

    2011-01-01

    Background: Candida albicans may have cariogenic potential but its role in caries etiology has not been established. The aim of this study was to determine candida albicans in supragingival dental plaque and infected dentine of cervical and proximal in early childhood caries (ECC). Methods: This cross-sectional study was carried out on 6o children aged 2-5 years, which were divided into 3 groups: children with at least one cervical caries; children with at least one proximal caries and caries-free. The infected dentine was collected from cervical and proximal caries lesions and plaque samples were collected from the three groups in order to compare the frequency of candida albicans in the collected sites. All samples were cultured in Sabouraud and CHROMagar medium and the cases that were positive for candida albicans were cultured in germ tube. Data were collected and analyzed. Results: The mean age of the children was 3.9 years. From 100 samples, candida albicans samples were isolated in 55%, mold fungi were found in 29% cases and there was no fungal growth in 16% of the samples. In plaque samples, candida albicans were found in 15% of caries-free samples, 20% of the proximal and 80% of the cervical caries. In samples extracted from the caries, candida albicans were found in 60% of the proximal and 100% of the cervical caries. Mothers with university educational level had children with more cervical decays, caries free and proximal caries, respectively. Conclusion: The results showed that prevalence of Candida albicans in dental plaque and caries lesions of children with early childhood caries were relatively high and the prevalence was higher in cervical caries group. PMID:24551436

  8. Experiences of PEMEX in CO{sub 2} re-injection; Experiencias de Pemex en reinyeccion de CO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Bujanos, Jose Luis [PEMEX (Mexico)

    2008-07-15

    Mexico enters the processes of secondary oil recovery the years 50s, by means of water injection. The CO{sub 2} injection is one of the techniques that better results produce in the oil recovery. In this presentation the strategic goals that have been determined within PEMEX Exploracion y Produccion (PEP) are mentioned, and which are the projects of CO{sub 2} injection for oil recovery already existing in Mexico. [Spanish] Mexico entra a los procesos de recuperacion secundaria de petroleo en los anos 50s, mediante inyeccion de agua. La inyeccion de CO{sub 2} es una de las tecnicas que mejores resultados produce en la recuperacion de petroleo. En esta presentacion se mencionan las metas estrategicas que se han fijado dentro de Pemex Exploracion y Produccion (PEP) y cuales son los proyectos de inyeccion de CO{sub 2} para recuperacion de petroleo, existentes actualmente en Mexico.

  9. The influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings: Part II - Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2006-01-01

    This is Part II of a two-part series of papers describing the effects of high pressure injection pockets on the operating conditions of tilting-pad thrust bearings. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approximately...... large discrepancies exist for the pad with an injection pocket. It is argued that this is likely to be due to the unevenness of the collar surface. The measured and theoretical values of oil film thickness compare well at low loads. At high loads discrepancies grow to up to 25 %. It is argued...

  10. Olanzapine Injection

    Science.gov (United States)

    ... of bed slowly, resting your feet on the floor for a few minutes before standing up.you should know that you may experience hyperglycemia (increases in your blood sugar) while you are taking this medication, even ...

  11. Zidovudine Injection

    Science.gov (United States)

    ... severe side effects, such as liver damage, blood toxicities, and muscle disorders. If you experience any of ... prescription and nonprescription medications you are taking, especially acetaminophen, acyclovir (Zovirax), aspirin, cancer chemotherapy, cimetidine (Tagamet), fluconazole ( ...

  12. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings - Part II: Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2007-01-01

    and approx. 4.0 MPa and velocities of up to 33 m/s. One pad has a plain surface. The other pad has a conical injection pocket at the pivot point and a leading-edge taper. The measurements are compared to theoretical values obtained using a three-dimensional thermoelastohydrodynamic (TEHD) numerical model...

  13. The influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings: Part II - Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2006-01-01

    This is Part II of a two-part series of papers describing the effects of high pressure injection pockets on the operating conditions of tilting-pad thrust bearings. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approximately...

  14. Performance Experiment of the Thermal Insulation Structure of Steam Injec-tion Boiler%注汽锅炉绝热结构性能实验

    Institute of Scientific and Technical Information of China (English)

    吴永宁; 周英; 赵海谦

    2016-01-01

    良好的绝热结构是注汽锅炉降低热能损失的前提.针对现有注汽锅炉绝热效果不理想的问题,对两种不同绝热敷设方式注汽锅炉的绝热效果进行现场检测,并对绝热材料性能进行室内实验研究.结果表明:随着使用时间延长,注汽锅炉绝热结构的绝热效果大幅度下降,折叠敷设方式稳定性优于平铺敷设方式;注汽锅炉绝热结构宜采用折叠敷设方式,且可将厚度适当压缩以提高强度.%Ideal thermal insulation structure is the key to ensuring the steam parameters of steam injection boiler and reducing heat loss.According to the present problems of steam in-jection boiler thermal insulation, insulation performance of steam injection boilers with dif-ferent thermal insulation construction method was tested on the spot, and the performances of thermal insulation material were researched. The results showed that insulation perfor-mance of steam injection boilers decreased sharply. Stability of folding laying method was better than tiling laying method.The folding laying method was suit for steam injection boiler. In order to enhancing the intension,the thickness should be compressed properly.

  15. Furosemide Injection

    Science.gov (United States)

    ... se mide)Furosemide can cause dehydration and electrolyte imbalance. If you experience any of the following symptoms, call your doctor immediately: decreased urination; dry mouth; thirst; nausea; vomiting; weakness; drowsiness; confusion; muscle pain or cramps; or rapid or pounding heartbeats.

  16. Mesna Injection

    Science.gov (United States)

    ... works by protecting against some of the harmful effects of certain chemotherapy medications. ... this medication.If you experience a serious side effect, you or your doctor may send a report to the Food and Drug Administration's (FDA) MedWatch Adverse Event Reporting program online (http://www.fda.gov/ ...

  17. Esclavitud, libertad y devoción religiosa en Popayán. El santo Ecce Homo y el mundo de la vida de Juan Antonio de Velasco, 1650-1700

    Directory of Open Access Journals (Sweden)

    Orián Jiménez Meneses

    2015-06-01

    Full Text Available This article analyzes the genesis and consolidation of devotion to the holy Ecce Homo in the city of Popayán —located in the New Kingdom of Granada— during the second half of the 17th century. It explores the influence of this mystical experience in crystalizing the city’s religious feasts and the cultural nuances that permeated this particular invocation. It also describes the relationship of interdependence between the liberty of the free black man Juan Antonio de Velasco and other merchants, slaves, artisans, and the devout public in stabilizing this particular form of worship of the holy one. At the same time that it specifically traces the “life world” of the founder and confrere of the tradition, it calls attention to the imprint he made on this religious ritual in Popayán, “the white city.” In addition to these social factors, it also shows the influence that the generalized natural crisis of the 17th century had on the emergence of new brotherhoods, rogation days and forms of devotion.

  18. SOFTWARE IMPLEMENTATION OF AN ECC ENCRYPTION ALGORITHM OVER PRIME FIELDS%素数域上ECC加密算法的软件实现

    Institute of Scientific and Technical Information of China (English)

    刘磊

    2012-01-01

    椭圆曲线密码是目前公认的每比特安全性最高的密码体制,它具有安全性高、速度快、密钥短、实现时所需占用资源少等优点,非常适合应用于银行结算、电子商务和通信等领域,因此研究椭圆曲线密码的实现有重要意义.首先讨论椭圆曲线密码基本理论,然后介绍安全椭圆曲线选取方法以及经典的ECC加密算法,最后在Core(TM)2 Duo CPU E7500 2.93GHz实验平台上用标准C语言对该算法进行实现,验证该加密算法的可行性.%The elliptic curve cryptography (ECC) is generally recognised at present as the most secure encryption system, which provides highest level of security strength-per-bit and has many advantages such as higher safety property, faster speed, shorter key lengths and fewer computational resources for implementation, and is very suitable for the sectors of bank settlement, e-commerce and communication. Therefore it is of significance to study the software implementation of ECC encryption algorithm. In this paper, we first introduce the basic theory of elliptic curve cryptography, and then describe the way to select a secure elliptic curve and the classic ECC encryption algorithm. Finally, we implement this algorithm in C and the assembler on a Core(TM)2 Duo CPU E75OO 2.93GHz workstation, and testify the feasibility of it.

  19. Reduction of plasma density in the Helicity Injected Torus with Steady Inductance experiment by using a helicon pre-ionization source.

    Science.gov (United States)

    Hossack, Aaron C; Firman, Taylor; Jarboe, Thomas R; Prager, James R; Victor, Brian S; Wrobel, Jonathan S; Ziemba, Timothy

    2013-10-01

    A helicon based pre-ionization source has been developed and installed on the Helicity Injected Torus with Steady Inductance (HIT-SI) spheromak. The source initiates plasma breakdown by injecting impurity-free, unmagnetized plasma into the HIT-SI confinement volume. Typical helium spheromaks have electron density reduced from (2-3) × 10(19) m(-3) to 1 × 10(19) m(-3). Deuterium spheromak formation is possible with density as low as 2 × 10(18) m(-3). The source also enables HIT-SI to be operated with only one helicity injector at injector frequencies above 14.5 kHz. A theory explaining the physical mechanism driving the reduction of breakdown density is presented.

  20. Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: initial experience in a swine model.

    Science.gov (United States)

    Numburi, Uma D; Kapadia, Samir R; Schoenhagen, Paul; Tuzcu, E Murat; von Roden, Martin; Halliburton, Sandra S

    2013-02-01

    To determine the optimal C-arm computed tomography (CT) protocol for transcatheter aortic valve implantation (TAVI) in swine. In 6 swine, C-arm CT was performed using 5-s ungated acquisition during sinus rhythm with aortic root (Method 1) or peripheral (Method 2) injection, and during rapid ventricular pacing with root injection (Method 3). Additionally, 24-s ECG-gated acquisitions were performed during sinus rhythm with root (Method 4) or peripheral (Method 5) injection. Aortic root enhancement, presence of artifacts and contrast volumes were compared for all methods. Aortic root measurements were also compared between C-arm CT and multidetector-row computed tomography (MDCT). The best C-arm CT image set was identified and used to predict optimal angiographic projection angles during TAVI; predictions were compared to those from MDCT. Methods 1, 3, 4, and 5 yielded sufficient root enhancement with mild or moderate artifacts and aortic annulus, sinotubular junction, and mid-ascending aorta diameters similar to MDCT. Ungated C-arm CT (Methods 1, 3) required less contrast than ECG-gated C-arm CT (Methods 4, 5). Method 3 was optimal yielding images with high attenuation, few artifacts (2.0), and root measurements similar to MDCT using minimal contrast (36 mL). Predicted angiographic projections from Method 3 were similar to MDCT. Ungated C-arm CT during rapid pacing with aortic root injection required minimal contrast, yielded high attenuation and few artifacts, and aortic root measurements and predicted angiographic planes similar to those from MDCT.

  1. 基于ECC的认证协议及动态密钥管理方案%The Authentication Protocol and Dynamic Key Management Based on ECC

    Institute of Scientific and Technical Information of China (English)

    曹阳

    2009-01-01

    针对当前无线网络中认证和密钥管理存在的安全缺陷,通过对椭圆曲线密码体制(ECC)的研究,结合ECMOV密钥协商协议和IEEE 802.1X扩展认证协议EAP-TLS及X.509证书,提出了一种在无线局域网中基于ECC的双向认证协议及密钥管理方案.

  2. Preliminary analysis of modeling of Pars and steam injectors to support long-term operation of LWR passive ECCS using a best estimate thermal-hydraulics code

    Energy Technology Data Exchange (ETDEWEB)

    Morales S, J. B.; Sanchez J, J. [UNAM, Facultad de Ingenieria, Circuito Interior s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Espinosa P, G., E-mail: jaimebmoraless@gmail.co [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico)

    2010-10-15

    In order to control the amount of hydrogen produced, during the chemical reaction of steam and strongly overheated zirconium in a LWR severe accident, several control methos have been proposed. In a considerable number of nuclear power plants the initial preferred solution was either the use of an inert containment atmosphere or the use of igniters. However, the use of Pars (Passive autocatalytic recombiners) has been considered an important addition to this set of H{sub 2} controls. Pars have appealing features such as, low maintenance, do not require active components to start operation, and can initiate the H{sub 2} and O{sub 2} recombination at low concentrations. However, under certain conditions these Pars may trigger H{sub 2} ignition leading to deflagration s with possible containment damages. Combustions, poisons and liquid may inhibit or reduce the Pars operation. Advanced LWR designs (generation III + and IV) are also considering the use of Pars as a supporting system to the long term operation of their passive ECCS (Emergency Core Cooling Systems) because they may transport the energy of containment H{sub 2} and O{sub 2} gases to external sinks. Even when the ECCS of modern nuclear power plants are designed to maintain containment conditions under established limits, there are small amounts of O{sub 2} and H{sub 2} produced mainly by H{sub 2}O radiolysis, and after several days of containment isolation, these gases may accumulate in places where the possibility of a H{sub 2} deflagration increases. Therefore, the use of Pars looks initially as an interesting solution to long-term H{sub 2} control during a Dba. However, the H{sub 2} and O{sub 2} recombination is an exothermic process resulting in additional steam and energy releases to the containment. In order to avoid a direct deposition of the steam and energy (Pars produced) into the containment atmosphere, we propose to use them to operate steam injectors that can bring cold water to replenish ECCS

  3. Injection of zinc in plants of ANAV. Impact on fuel and operation experience; Inyeccion de cinc en las plantas de ANAV. Impacto sobre el combustible y experiencia de operacion

    Energy Technology Data Exchange (ETDEWEB)

    Doncell, N.; Gago, J. L.

    2015-07-01

    Zinc injection performed in the three ANAV (Asociacion Nuclear Asco-Vandellos) plants is part of an overall primary water chemistry program, material management and dose reduction program. The application of zinc shown significant benefits in radiation field reduction as well as in mitigation of PWSCC initiation. Although zinc injection also reduces general corrosion rates and consequently reduces corrosion product transport to the fuel, and evaluation of the risks with respect to fuel performance should be done. ANAV and ENUSA, following industry recommendations, have coordinated the task related to the viability of the program in Asco and Vandellos including monitoring, inspections and control parameters. finally, this article includes a comprehensive review of operating experience and an assessment of fuel performance effects. (Author)

  4. Reflooding and boil-off experiments in a VVER-440 like rod bundle and analyses with the CATHARE code

    Energy Technology Data Exchange (ETDEWEB)

    Korteniemi, V.; Haapalehto, T. [Lappeenranta Univ. of Technology (Finland); Puustinen, M. [VTT Energy, Lappeenranta (Finland)

    1995-09-01

    Several experiments were performed with the VEERA facility to simulate reflooding and boil-off phenomena in a VVER-440 like rod bundle. The objective of these experiments was to get experience of a full-scale bundle behavior and to create a database for verification of VVER type core models used with modern thermal-hydraulic codes. The VEERA facility used in the experiments is a scaled-down model of the Russian VVER-440 type pressurized water reactors used in Loviisa, Finland. The test section of the facility consists of one full-scale copy of a VVER-440 reactor rod bundle with 126 full-length electrically heated rod simulators. Bottom and top-down reflooding, different modes of emergency core cooling (ECC) injection and the effect of heating power on the heat-up of the rods was studied. In this paper the results of calculations simulating two reflood and one boil-off experiment with the French CATHARE2 thermal-hydraulic code are also presented. Especially the performance of the recently implemented top-down reflood model of the code was studied.

  5. Bias in peak clad temperature predictions due to uncertainties in modeling of ECC bypass and dissolved non-condensable gas phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Rohatgi, U.S.; Neymotin, L.Y.; Jo, J.; Wulff, W. (Brookhaven National Lab., Upton, NY (USA))

    1990-09-01

    This report describes a general method for estimating the effect on the Reflood Phase PCT from systematic errors (biases) associated with the modelling of the ECCS and dissolved nitrogen, and the application of this method in estimating biases in the Reflood Phase PCT (second PCT) predicted by the TRAC/PF1/MOD1, Version 14.3. The bias in the second PCT due to the uncertainty in the existing code models for ECCS related phenomena is {minus}19{degree}K ({minus}34{degree}F). The negative bias implies that the code models for this phenomena are conservative. The bias in the second PCT due to the lack of modelling of dissolved N{sub 2} in the code is estimated to be 9.9{degree}K (17.8{degree}F). The positive bias implies that the absence of dissolved N{sub 2} model makes the code prediction of PCT non-conservative. The bias estimation in this report is a major exception among all other uncertainty and bias assessments performed in conjunction with the CSAU methodology demonstration, because this bias estimation benefitted from using full-scale test data from the full-scale Upper Plenum Test Facility (UPTF). Thus, the bias estimates presented here are unaffected by scale distortions in test facilities. Data from small size facilities were also available and an estimate of bias based on these data will be conservative. 35 refs., 18 figs., 5 tabs.

  6. Helpful tips for performing musculoskeletal injections.

    Science.gov (United States)

    Metz, John P

    2010-01-01

    Injections are valuable procedures for managing musculoskeletal conditions commonly encountered by family physicians. Corticosteroid injections into articular, periarticular, or soft tissue structures relieve pain, reduce inflammation, and improve mobility. Injections can provide diagnostic information and are commonly used for postoperative pain control. Local anesthetics may be injected with corticosteroids to provide additional, rapid pain relief. Steroid injection is the preferred and definitive treatment for de Quervain tenosynovitis and trochanteric bursitis. Steroid injections can also be helpful in controlling pain during physical rehabilitation from rotator cuff syndrome and lateral epicondylitis. Intra-articular steroid injection provides pain relief in rheumatoid arthritis and osteoarthritis. There is little systematic evidence to guide medication selection for therapeutic injections. The medication used and the frequency of injection should be guided by the goal of the injection (i.e., diagnostic or therapeutic), the underlying musculoskeletal diagnosis, and clinical experience. Complications from steroid injections are rare, but physicians should understand the potential risks and counsel patients appropriately. Patients with diabetes who receive periarticular or soft tissue steroid injections should closely monitor their blood glucose for two weeks following injection.

  7. Musculoskeletal injections: a review of the evidence.

    Science.gov (United States)

    Stephens, Mark B; Beutler, Anthony I; O'Connor, Francis G

    2008-10-15

    Injections are valuable procedures for managing musculoskeletal conditions commonly encountered by family physicians. Corticosteroid injections into articular, periarticular, or soft tissue structures relieve pain, reduce inflammation, and improve mobility. Injections can provide diagnostic information and are commonly used for postoperative pain control. Local anesthetics may be injected with corticosteroids to provide additional, rapid pain relief. Steroid injection is the preferred and definitive treatment for de Quervain tenosynovitis and trochanteric bursitis. Steroid injections can also be helpful in controlling pain during physical rehabilitation from rotator cuff syndrome and lateral epicondylitis. Intra-articular steroid injection provides pain relief in rheumatoid arthritis and osteoarthritis. There is little systematic evidence to guide medication selection for therapeutic injections. The medication used and the frequency of injection should be guided by the goal of the injection (i.e., diagnostic or therapeutic), the underlying musculoskeletal diagnosis, and clinical experience. Complications from steroid injections are rare, but physicians should understand the potential risks and counsel patients appropriately. Patients with diabetes who receive periarticular or soft tissue steroid injections should closely monitor their blood glucose for two weeks following injection.

  8. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to treat ... in the treatment of certain serious infections. Penicillin G procaine injection is in a class of medications ...

  9. Nietzsche como destino da filosofia e da humanidade? interpretação contextual do § 1 do capítulo "por que sou um destino", de ecce homo

    Directory of Open Access Journals (Sweden)

    Werner Stegmaier

    2010-01-01

    Full Text Available The following translation is a reduced and revised version of the paper Schicksal Nietzsche? Zu Nietzsches Selbsteinschätzung als Schicksal der Philosophie und der Menschheit (Ecce Homo, Warum ich ein Schicksal bin §1" - originally published in Nietzsche-Studien 37 (2008 - which was specially prepared to be presented in lecture organized by the Grupo de Pesquisa Spinoza & Nietzsche (Spinoza & Nietzsche research group - SpiN, in the Universidade Federal do Rio de Janeiro (Rio de Janeiro's Federal University, on September 14, 2009. In the text, the autor employs his own philological-hermeneutical methodology, which is called contextual interpretation, in the purpose to clarify the concepts of the first aphorism from "Why I am a destiny", from Ecce Homo, in its own context, in the context of Ecce Homo and in the context of the entire work from Nietzsche.

  10. Nietzsche como destino da filosofia e da humanidade? interpretação contextual do § 1 do capítulo "por que sou um destino", de ecce homo

    Directory of Open Access Journals (Sweden)

    Werner Stegmaier

    2011-01-01

    Full Text Available A tradução que se segue é uma versão resumida e revisada do artigo "Schicksal Nietzsche? Zu Nietzsches Selbsteinschätzung als Schicksal der Philosophie und der Menschheit (Ecce Homo, Warum ich ein Schicksal bin §1" - publicado originalmente em Nietzsche-Studien 37 (2008 - que foi especialmente preparada para ser apresentada em palestra organizada pelo Grupo de Pesquisa Spinoza & Nietzsche (SpiN, na Universidade Federal do Rio de Janeiro, em 14/09/2009. No texto, o autor faz uso de sua própria metodologia filológico-hermenêutica, denominada interpretação contextual, com vistas a esclarecer os conceitos do primeiro aforismo de "por que sou um destino", de Ecce Homo no seu contexto próprio, no contexto de Ecce Homo e no contexto da obra de Nietzsche como um todo.

  11. Manual small incision cataract surgery (MSICS) with posterior chamber intraocular lens versus extracapsular cataract extraction (ECCE) with posterior chamber intraocular lens for age-related cataract.

    Science.gov (United States)

    Ang, Marcus; Evans, Jennifer R; Mehta, Jod S

    2014-11-18

    Age-related cataract is the opacification of the lens, which occurs as a result of denaturation of lens proteins. Age-related cataract remains the leading cause of blindness globally, except in the most developed countries. A key question is what is the best way of removing the lens, especially in lower income settings. To compare two different techniques of lens removal in cataract surgery: manual small incision surgery (MSICS) and extracapsular cataract extraction (ECCE). We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 8), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to September 2014), EMBASE (January 1980 to September 2014), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to September 2014), Web of Science Conference Proceedings Citation Index- Science (CPCI-S), (January 1990 to September 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 23 September 2014. We included randomised controlled trials (RCTs) only. Participants in the trials were people with age-related cataract. We included trials where MSICS with a posterior chamber intraocular lens (IOL) implant was compared to ECCE with a posterior chamber IOL implant. Data were collected independently by two authors. We aimed to collect data on presenting visual acuity 6/12 or better and best-corrected visual acuity of less than 6/60 at three months and one year after surgery. Other outcomes included intraoperative complications, long-term complications (one year or more after surgery), quality of life, and cost

  12. Iron Dextran Injection

    Science.gov (United States)

    ... allergic to iron dextran injection; any other iron injections such as ferric carboxymaltose (Injectafer), ferumoxytol (Feraheme), iron sucrose (Venofer), or sodium ferric gluconate (Ferrlecit);any other ...

  13. Full scale calcium bromide injection with subsequent mercury oxidation and removal within wet flue gas desulphurization system: Experience at a 700 MW coal-fired power facility

    Science.gov (United States)

    Berry, Mark Simpson

    The Environmental Protection Agency promulgated the Mercury and Air Toxics Standards rule, which requires that existing power plants reduce mercury emissions to meet an emission rate of 1.2 lb/TBtu on a 30-day rolling average and that new plants meet a 0.0002 lb/GWHr emission rate. This translates to mercury removals greater than 90% for existing units and greater than 99% for new units. Current state-of-the-art technology for the control of mercury emissions uses activated carbon injected upstream of a fabric filter, a costly proposition. For example, a fabric filter, if not already available, would require a 200M capital investment for a 700 MW size unit. A lower-cost option involves the injection of activated carbon into an existing cold-side electrostatic precipitator. Both options would incur the cost of activated carbon, upwards of 3M per year. The combination of selective catalytic reduction (SCR) reactors and wet flue gas desulphurization (wet FGD) systems have demonstrated the ability to substantially reduce mercury emissions, especially at units that burn coals containing sufficient halogens. Halogens are necessary for transforming elemental mercury to oxidized mercury, which is water-soluble. Plants burning halogen-deficient coals such as Power River Basin (PRB) coals currently have no alternative but to install activated carbon-based approaches to control mercury emissions. This research consisted of investigating calcium bromide addition onto PRB coal as a method of increasing flue gas halogen concentration. The treated coal was combusted in a 700 MW boiler and the subsequent treated flue gas was introduced into a wet FGD. Short-term parametric and an 83-day longer-term tests were completed to determine the ability of calcium bromine to oxidize mercury and to study the removal of the mercury in a wet FGD. The research goal was to show that calcium bromine addition to PRB coal was a viable approach for meeting the Mercury and Air Toxics Standards rule

  14. Transient Enhancement ('Spike-on-Tail') Observed on Neutral-Beam-Injected Energetic Ion Spectra Using the E||B Neutral Particle Analyzer in the National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Medley, S. S. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Gorelenkov, N. N. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Bell, R. E. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Fredrickson, E. D. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Gerhardt, S. P. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); LeBlanc, B. P. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Podesta, M. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Roquemore, A. L. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)

    2010-06-01

    An increase of up to four-fold in the E||B Neutral Particle Analyzer (NPA) charge exchange neutral flux localized at the Neutral Beam (NB) injection full energy is observed in the National Spherical Torus Experiment (NSTX). Termed the High-Energy Feature (HEF), it appears on the NB-injected energetic ion spectrum only in discharges where tearing or kink-type modes (f < 10 kHz) are absent, TAE activity (f ~ 10-150 kHz) is weak (δBrms < 75 mGauss) and CAE/GAE activity (f ~ 400 – 1200 kHz) is robust. The feature exhibits a growth time of ~ 20 - 80 ms and occasionally develops a slowing down distribution that continues to evolve over periods of 100's of milliseconds, a time scale long compared with the typical ~ 10's ms equilibration time of the NB injected particles. The HEF is observed only in H-mode (not L-mode) discharges with injected NB power of 4 MW or greater and in the field pitch range v||/v ~ 0.7 – 0.9; i.e. only for passing (never trapped) energetic ions. The HEF is suppressed by vessel conditioning using lithium deposition at rates ~ 100 mg/shot, a level sufficient to suppress ELM activity. Increases of ~ 10 - 30 % in the measured neutron yield and total stored energy are observed to coincide with the feature along with broadening of measured Te(r), Ti(r) and ne(r) profiles. However, TRANSP analysis shows that such increases are driven by plasma profile changes and not the HEF phenomenon itself. Though a definitive mechanism has yet to be developed, the HEF appears to be caused by a form of TAE/CAE wave-particle interaction that distorts of the NB fast ion distribution in phase space.

  15. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...

  16. Surgical management of stress urinary incontinence: Burch colposuspension, modified Pereyra and Stamey bladder neck suspension, and collagen injection--Toa Payoh Hospital experience.

    Science.gov (United States)

    Tay, K P; Lim, P H; Chng, H C

    1995-12-01

    A retrospective analysis was performed on 34 female patients who underwent corrective surgery for stress urinary incontinence over a 4-year period at the Toa Payoh Hospital. These patients were offered surgery only after an adequate trial of medical therapy, pelvic floor exercises and weight reduction. Bladder neck suspension operations were performed via the Burch, Stamey and modified Pereyra techniques. Towards the later part of this study, endoscopic injection of Collagen was performed as a salvage procedure in 2 patients. The Burch colposuspension gave uniformly good results, with all patients being completely dry. Seventy percent and sixty percent complete continence were achieved via the modified Pereyra and Stamey techniques respectively. Three patients required additional surgical procedures. Using these techniques, the overall results showed that 27 patients (79.4%) had complete urinary continence following surgery, while the remaining 7 patients (20.6%) experienced significant improvement of symptoms.

  17. Sipuleucel-T Injection

    Science.gov (United States)

    Sipuleucel-T injection is used to treat certain types of advanced prostate cancer. Sipuleucel-T injection is in a class of medications called ... Sipuleucel-T injection comes as a suspension (liquid) to be injected over about 60 minutes into a vein ...

  18. Experiments on gas injection mechanisms in carbonate fracture-cavity reservoir using microvisual model%碳酸盐岩缝洞型油藏气驱机制微观可视化模型试验

    Institute of Scientific and Technical Information of China (English)

    郭平; 袁恒璐; 李新华; 马洪涛

    2012-01-01

    In fracture-cavity carbonate reservoirs,there are generally two kinds of fracture-cavities whose fracture opening are upward and downward respectively. A microvisual model was established to investigate the displacement mechanisms of gas and liquid flooding. Under normal temperature and low pressure, simulated oil and liquid gas were used to do four groups of experiments including water displacement, active water displacement, direct gas displacement and gas-alternating-water displacement. And the effects of different injected fluids and injected methods on displacement efficiency and water cut were researched. The results show that the displacement efficiencies of water displacement, active water displacement, gas displacement and gas-alternating-water displacement are 81. 12% , 68. 95% , 74. 88% and 99. 84% , respectively. The best injection method is gas-alternating-water in fracture-cavity reservoir. Gas injection can only displace the oil in cavities whose fracture openings are downward, and water injection can only displace those whose fracture openings are upward, but gas-alternating-water method can settle down both. Due to the low capillary pressure, active water is no good for oil displacement.%针对缝洞型碳酸盐岩油藏开发中开口向上和开口向下两种缝洞类型,建立该类油藏气驱机制下的微观可视模型,采用模拟油和液化气,在常温低压下进行水驱、活性水驱、直接注气驱及气-水交替驱4组试验,研究不同注入流体及注入方式对驱替效率和含水率的影响.结果表明:水驱、活性水驱、气驱和气-水交替驱的驱替效率分别为81.12%、68.95%、74.88%和99.84%,缝洞型油藏的最佳注入方式为气-水交替注入;注气只能驱开向下的洞,注水只能驱替开口向上的洞,气-水交替驱可以同时解决这两种洞的驱油问题;活性水由于毛管压力低不利于驱油.

  19. The influence of plasma horizontal position on the neutron rate and flux of neutral atoms in injection heating experiment on the TUMAN-3M tokamak

    Science.gov (United States)

    Kornev, V. A.; Chernyshev, F. V.; Melnik, A. D.; Askinazi, L. G.; Wagner, F.; Vildjunas, M. I.; Zhubr, N. A.; Krikunov, S. V.; Lebedev, S. V.; Razumenko, D. V.; Tukachinsky, A. S.

    2013-11-01

    Horizontal displacement of plasma along the major radius has been found to significantly influence the fluxes of 2.45 MeV DD neutrons and high-energy charge-exchange atoms from neutral beam injection (NBI) heated plasma of the TUMAN-3M tokamak. An inward shift by Δ R = 1 cm causes 1.2-fold increase in the neutron flux and 1.9-fold increase in the charge-exchange atom flux. The observed increase in the neutron flux is attributed to joint action of several factors-in particular, improved high-energy ion capture and confinement and, probably, decreased impurity inflow from the walls, which leads to an increase in the density of target ions. A considerable increase in the flux of charge-exchange neutrals in inward-shifted plasma is due to the increased number of captured high-energy ions and, to some extent, the increased density of the neutral target. As a result of the increase in the content of high-energy ions, the central ion temperature T i (0) increased from 250 to 350 eV. The dependence of the neutron rate on major radius R 0 should be taken into account when designing compact tokamak-based neutron sources.

  20. First experience with intracytoplasmic sperm injection for extreme oligozoospermia associated with Crohn‘s disease and 6—mercaptopurine chemotherapy

    Institute of Scientific and Technical Information of China (English)

    E.ScottSills; MichaelJ.Tucker

    2003-01-01

    Aim:To describe the reproductive outcome following intracytoplasmic sperm injection(ICSI)for male factor infertility associated with Crohn's disease and 6-mercaptopurine(6-MP) chemotherapy.Methods:The male partner of a couple suffered from severe Crohn's disease and received a 3-month course of 6-MP for this condition.Two spontaneous conceptions were established before 6-MP,although post-chemotherapy semen analysis found the sperm concentration to be 8,000/mL.In vitro fertilization(IVF)with ICSI and embryo transfer was performed.Results:The woman underwent an uncomplicated controlled ovarian hyperstimulation sequence using a combined rec-FSH+hMG protocol,following late luteal phase pituitary downregulation.This culminated in the retrieval of 18 oocytes,11 of which were fertilized with ICSI.She later delivered a normal male infant without urogenital anomaly.Four nontransferred blastocysts were cryopreserved.Conclusion:This report describes the first successful birth after ICSI for severe oligozoospermia associated with Crohn''''s disease and 6-MP therapy.We outline salient features of Crohn's disease,6-MP pharmacology,and their relevance to human fertility.

  1. Structured extracapsular cataract extraction-intraocular lens microsurgical training: report of a trainee's experience.

    Science.gov (United States)

    Aghaji, A E; Natchiar, G

    2011-01-01

    The aim was to report the experience an ophthalmologist gained in a structured intraocular lens (IOL) microsurgery training program for the information and benefit of colleagues in ophthalmology training institutions. An ophthalmologist was trained in extracapsular cataract extraction (ECCE)-IOL implant in Aravind Eye Hospital (AEH), Madurai, for a period of 8 weeks. Details of patients operated on, procedures observed, and conferences attended were prospectively recorded in a log book. Training was available in conventional ECCE with posterior chamber IOL (ECCE-PCIOL), small incision sutureless cataract surgery, and phacoemulsification. During the period, this trainee observed a total of 1527 cataract extractions, administered 528 retrobulbar and 1047 facial blocks, and also operated on 75 patients. The trainee gained experience and confidence to perform high-quality, low-cost cataract surgery. Hands-on experience and competence in quality ECCE-IOL implant microsurgery can be acquired in a short period of time in a high-volume cataract center. Trainees can also be exposed to other techniques of cataract surgery. Ophthalmology training centers with diminishing surgical training opportunities can also benefit from this structured training in a high-volume cataract center like Aravind Eye Hospital.

  2. On Maximal Injectivity

    Institute of Scientific and Technical Information of China (English)

    Ming Yi WANG; Guo ZHAO

    2005-01-01

    A right R-module E over a ring R is said to be maximally injective in case for any maximal right ideal m of R, every R-homomorphism f : m → E can be extended to an R-homomorphism f' : R → E. In this paper, we first construct an example to show that maximal injectivity is a proper generalization of injectivity. Then we prove that any right R-module over a left perfect ring R is maximally injective if and only if it is injective. We also give a partial affirmative answer to Faith's conjecture by further investigating the property of maximally injective rings. Finally, we get an approximation to Faith's conjecture, which asserts that every injective right R-module over any left perfect right self-injective ring R is the injective hull of a projective submodule.

  3. Effect of Injection Flow Rate on Product Gas Quality in Underground Coal Gasification (UCG Based on Laboratory Scale Experiment: Development of Co-Axial UCG System

    Directory of Open Access Journals (Sweden)

    Akihiro Hamanaka

    2017-02-01

    Full Text Available Underground coal gasification (UCG is a technique to recover coal energy without mining by converting coal into a valuable gas. Model UCG experiments on a laboratory scale were carried out under a low flow rate (6~12 L/min and a high flow rate (15~30 L/min with a constant oxygen concentration. During the experiments, the coal temperature was higher and the fracturing events were more active under the high flow rate. Additionally, the gasification efficiency, which means the conversion efficiency of the gasified coal to the product gas, was 71.22% in the low flow rate and 82.42% in the high flow rate. These results suggest that the energy recovery rate with the UCG process can be improved by the increase of the reaction temperature and the promotion of the gasification area.

  4. Solid Organic Deposition During Gas Injection Studies

    DEFF Research Database (Denmark)

    Dandekar, Abhijit Y.; Andersen, Simon Ivar; Stenby, Erling Halfdan

    2000-01-01

    Recently a series of first contact miscibility (swelling) experiments have been performed on undersaturated light and heavy oils using LPG rich and methane rich injection gases, in which solid organic deposition was observed. A compositional gradient in the oils during the gas injection process w...

  5. Aplicação das técnicas de planejamento e análise de experimentos no processo de injeção plástica Application design of experiments in the injection molding process

    Directory of Open Access Journals (Sweden)

    Edwin V. Cardoza Galdamez

    2004-04-01

    Full Text Available Experimentos industriais são realizados pelas empresas com o intuito de melhorar o desempenho dos produtos e os processos de fabricação. Nesse sentido, este trabalho tem por objetivo estudar e aplicar as técnicas de planejamento e análise de experimentos na melhoria da qualidade industrial. Especificamente são aplicadas as técnicas de planejamento Fatorial Fracionado 2k-p, Metodologia de Superfície de Resposta e Análise de Variância, em um processo de moldagem por injeção plástica. Com essa pesquisa experimental foi possível identificar os níveis ótimos de regulagem e os parâmetros mais importantes da injeção plástica: temperatura da máquina e pressão de injeção. Para finalizar é avaliado o procedimento de implementação das técnicas de experimentação e as dificuldades práticas encontradas na empresa.Industrial experiments are made by companies in order to improve the quality characteristics of products and production processes. In this sense, the objective of this paper is to study and apply the design of experiments in the industrial quality improvement. In addition, as a part of the objective, an application of the techniques of design Fractional Factorial 2k-p, Analysis of Variance and Response Surface Methodology is done. It is focused in an injection molding process applied by a company, that makes and trades plastic products for the civil construction. Using this experimental study, the most important parameters of plastic injection are identified: machine temperature and injection pressure. At the same time, the optimal levels of adjustment of these parameters are determined. From this study, it is evaluated both the implantation procedures of the designs of experiments as well as the difficulties faced. Also, this study tries to contribute to the university-company relationship.

  6. Crack Distribution and Mechanical Performance of Self-healing of Engineered Cementitious Composites(ECC) Materials%工程水泥基材料裂缝分布及自愈合后力学性能

    Institute of Scientific and Technical Information of China (English)

    阚黎黎; 施惠生

    2012-01-01

    Crack distribution, mechanical performance recovery of self-healing engineered cementitious composites(ECC) materials under wet/dry conditioning cycles and nano-identation analyses of the microphases in ECC at 0. 3%, 0. 5%, 1. 0% and 2. 0% pre-loading were investigated. The results suggest that ECC has many characteristics that contribute to self-healing behavior. Majority of ECC cracks are below 30 μm in width. Both ultimate tensile strength and tensile strain capacity of the majority specimens at reloading are higher than the control specimens. The modulus of elasticity, hardness and stiffness of healed products is about 34. 8 Gpa, 1. 6 Gpa and 0. 1 mN/nm respectively.%在0.3%,0.5%,1.0%,2.0%预加拉伸应变破坏下,进行了2种配比、不同龄期的工程水泥基复合材料(ECC)的裂缝分布、干湿循环自愈合后力学性能的恢复及不同物相的纳米压痕测试.结果表明:ECC具有很多有利于裂缝自愈合行为的特性,其裂缝宽度大都在30μm以下,自愈合后,其最终强度及拉伸应变能力均能达到甚至超过对比试件,裂缝自愈合产物的弹性模量约为34.8 GPa,硬度约为1.6 GPa,刚度约为0.1 mN/nm.

  7. Epoetin Alfa Injection

    Science.gov (United States)

    ... Combivir), a medication used to treat human immunodeficiency virus (HIV). Epoetin alfa injection is also used before ... inject epoetin alfa, as directed by your doctor. Write down the date, time, dose of epoetin alfa ...

  8. Collagenase Clostridium Histolyticum Injection

    Science.gov (United States)

    Collagenase Clostridium histolyticum injection is used to treat Dupuytren's contracture (a painless thickening and tightening of tissue [cord] beneath ... of tissue can be felt upon examination. Collagenase Clostridium histolyticum injection is also used to treat Peyronie's ...

  9. Iron Sucrose Injection

    Science.gov (United States)

    Iron sucrose injection is used treat iron-deficiency anemia (a lower than normal number of red blood cells due ... and may cause the kidneys to stop working). Iron sucrose injection is in a class of medications called iron ...

  10. Intracytoplasmic sperm injection

    Science.gov (United States)

    Intracytoplasmic sperm injection, or ICSI, is a form of in vitro fertilization in which fertilization occurs outside of the ... laboratory dish. Within a few hours, a single sperm is injected through a fine needle into the ...

  11. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  12. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  13. Other Injectable Medications

    Science.gov (United States)

    ... July 17, 2013 Last Edited: February 22, 2017 Articles from Diabetes Forecast® magazine: cg-infusion-sets,meds-bg-injectables,cg-injection-aids, In this section Treatment and Care Medication Insulin & ...

  14. Injection losses and protection

    CERN Document Server

    Bartmann, W; Baudrenghien, P; Bracco, C; Dehning, B; Di Mauro, A; Drosdal, L; Emery, J; Goddard, B; Holzer, E B; Höfle, W; Kain, V; Meddahi, M; Radaelli, S; Shaposhnilova, E; Uythoven, J; Valuch, D; Wenninger, J; Zamantzas, C; Gianfelice-Wendt, E

    2012-01-01

    Injection losses are compared for 2010 and 2011 operation. Mitigation techniques which were put in place in 2010 to reduce losses at injection are described. Issues in 2011 operation, their potential improvements and the performance reach for 2012 are shown.

  15. Mitomycin C-augmented trabeculectomy: subtenon injection versus soaked sponges: a randomised clinical trial.

    Science.gov (United States)

    Pakravan, Mohammad; Esfandiari, Hamed; Yazdani, Shahin; Douzandeh, Azadeh; Amouhashemi, Nassim; Yaseri, Mehdi; Pakravan, Parto

    2017-09-01

    To compare the efficacy and safety of subtenon injection of mitomycin C (MMC) with that of conventional application of MMC-soaked sponges in trabeculectomy. In this multicentre randomised clinical trial, 80 consecutive open-angle glaucoma cases were randomised into two groups; group 1 received a subtenon injection of 0.1 mL of 0.01% MMC, while group 2 received 0.02% MMC-soaked sponges. Primary outcome measure was intraocular pressure (IOP), and secondary outcome measures were endothelial cell count (ECC) changes and bleb morphology according to the Indiana Bleb Appearance Grading Scale. Outcome measures were compared at 1, 3 and 6 months postoperatively. Complete and qualified success was defined as IOP within 6-15 mm Hg without and with medications at month 6, respectively. Mean preoperative IOP was 21.8±5.1 in group 1, which reduced to 10.3±3.7 mm Hg at final visit (p<0.001). Corresponding values for group 2 were 21.8±5 and 10.8±3.5 mm Hg respectively (p<0.001). Complete success was 82.5% in both groups, and qualified success was 0 and 2.5% in groups 1 and 2, respectively. (p=0.316) The blebs tended to be more diffuse, less vascularised and shallower in group 1, at month 6 (p=0.45,<0.001 and <0.007 respectively). ECCs did not change significantly at final visit (p=0.813). Subtenon injection of MMC is a safe and effective alternative to the conventional soaked sponge method. This method produces more favourable bleb morphology after trabeculectomy. NCT02385370, Post-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Beam injection into RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

    1997-07-01

    During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

  17. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  18. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  19. 有静脉注射海洛因病史患者30例中心静脉穿刺置管体会%Experience of central venous catheterization on 30 patients with a history of heroin injection

    Institute of Scientific and Technical Information of China (English)

    何吉飞

    2016-01-01

    目的:探讨有静脉注射海洛因病史的患者行中心静脉穿刺置管术的方法。方法:对30例有静脉注射海洛因病史的患者行中心静脉穿刺置管术。结果:30例中心静脉穿刺置管均成功,其中1次穿刺成功23例,更换部位后穿刺成功7例。穿刺部位:右侧锁骨下19例,右侧颈内8例,左侧颈内3例。结论:静脉注射海洛因患者中心静脉穿刺置管较困难,通过积累经验,充分准备,熟练操作,才能提高对该类患者中心静脉穿刺置管成功率。%Objective:To investigate the method of central venous catheterization in patients with a history of heroin injection. Methods:30 patients with a history of heroin injection were treated with central venous catheterization.Results:All of those 30 cases with central venous catheterization were successful,in which there were 23 cases successful puncture at once,another 7 cases were successful puncture after changing the puncture site.Puncture site:19 cases on the right side of the clavicle,8 cases on the right side of the neck,3 cases on the left side of the internal carotid.Conclusion:Central venous catheterization on patient with a history of intravenous injection of heroin is more difficult,need to accumulate experience,fully prepared and skilled operation,to improve the success rate of the central vein puncture catheter.

  20. Endovascular treatment for dural arteriovenous fistula at the foramen magnum: report of five consecutive patients and experience with balloon-augmented transarterial Onyx injection.

    Science.gov (United States)

    Liang, Guobiao; Gao, Xu; Li, Zhiqing; Wang, Xiaogang; Zhang, Haifeng; Wu, Zhongxue

    2013-05-01

    Foramen magnum dural arteriovenous fistulas (DAVF) with perimedullary venous drainage represent a small minority of intracranial DAVF, and only a number of small series with limited cases have been reported. The purpose of this retrospective study is to summarize experience of transarterial Onyx embolisation in the treatment of these lesions, with emphasis on the balloon-augmented technique. Five consecutive patients with DAVF at the foramen magnum were treated by transarterial embolisation using the Onyx system. Their symptoms included myelopathy (n=4) and SAH (n=1). Suppliers were from the vertebral artery (VA) (n=4), occipital artery (OA) (n=4), and ascending pharyngeal artery (APA) (n=2), with drainage to the perimedullary veins. After catheterization of the dilated supplier, the fistulous connections, proximal draining veins and appropriate distal segment of the feeders of these DAVF were transarterial embolized using Onyx-18. In three patients, balloon-augmented technique was used to assist embolisation. The technical feasibility of the procedure, angiographic results, and clinical outcome were evaluated. In every case, complete obliteration was achieved. Neither intraprocedural vessel rupture nor other procedure-related complications occurred. The results remained stable in all patients on follow-up angiograms (mean, 7.2 months). At the last clinical follow-up (mean, 17.6 months), two patients showed complete resolution of the initial symptoms, and three patients showed significant improvement. We found that Onyx embolisation is a feasible and safe alternative to open surgery in the treatment of selective DAVF at the foramen magnum. The balloon-augmented technique widens indications for transarterial Onyx packing of these lesions, and improved safety of the procedure. Copyright © 2013. Published by Elsevier Masson SAS.

  1. Analysis of Related Factors of Children S-ECC%S-ECC儿童乳牙患龋的主要相关因素分析

    Institute of Scientific and Technical Information of China (English)

    樊鲁娜; 王丁

    2013-01-01

    Objective To investigate S-ECC related behavioural and social factors by the way of questionnaire.To provide fundamental data and guidance for oral health care.Methods Oral examination and questionnaire in 3~6 years old children,Calculation and finishing using statistical software SPSS14.0.Results The main risk factors to S-ECC are the children life style,including feeding habits and frequency of sugar intakes,education of parents and attitudes to the oral health. Conclusion We should strengthen oral health education to the children and their parents,and the monitoring and evaluation of health education programs.Simple and effective health care project should be found to control the caries of deciduous teeth and improve the life quality in children.%  目的通过问卷调查的方式,希望能了解与S-ECC相关的行为和社会学因素,从而对今后乳牙龋病的预防治疗提供辅助依据。方法选择医院门诊和北京城市幼儿园中3~6岁儿童,进行口腔检查并对受检者的父亲或者母亲发放调查问卷。使用统计软件SPSS14.0进行计算和整理。结果无龋组和S-ECC组儿童的父母文化程度、儿童夜间饮奶习惯、常喝的饮品、睡前吃零食习惯和第一次看牙原因有显著差异。其他问卷中的因素,均无显著差异。结论应加强对儿童及家长的口腔健康教育,加强健康教育项目的监测与评估,寻找简单有效的保健项目,控制乳牙龋病,提高儿童生活质量。

  2. Epidural injections for back pain

    Science.gov (United States)

    ESI; Spinal injection for back pain; Back pain injection; Steroid injection - epidural; Steroid injection - back ... be pregnant What medicines you are taking, including herbs, supplements, and other drugs you bought without a ...

  3. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented including the following: Raft River Valley, Salton Sea, East Mesa, Otake, Hatchobaru, and Ahuachapan geothermal fields.

  4. Emulsion sheet doublets as interface trackers for the OPERA experiment

    CERN Document Server

    Anokhina, A.; Ariga, A.; Arrabito, L.; Autiero, D.; Badertscher, A.; Bay, F.; Greggio, F.Bersani; Bertolin, A.; Besnier, M.; Bick, D.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Carrara, E.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Consiglio, L.; Cozzi, M.; Cuha, V.; Dal Corso, F.; D'Amato, G.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Di Troia, C.; Dmitrievski, S.; Dominjon, A.; Dracos, Marcos; Duchesneau, D.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, Antonio; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Frekers, D.; Fukuda, T.; Galkin, V.I.; Galkin, V.A.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Goldberg, J.; Golubkov, D.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gusev, G.; Gustavino, C.; Hagner, Caren; Hara, T.; Hierholzer, M.; Hiramatsu, S.; Hoshino, Kaoru; Ieva, M.; Jakovcic, K.; Janicsko Csathy, J.; Janutta, B.; Jollet, C.; Juget, F.; Kawai, T.; Kazuyama, M.; Kim, S.H.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laktineh, I.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, Andrea; Lutter, G.; Manai, K.; Mandrioli, G.; Marotta, A.; Marteau, J.; Matsuo, T.; Matsuoka, H.; Mauri, N.; Meisel, F.; Meregaglia, A.; Messina, M.; Migliozzi, P.; Mikado, S.; Miyamoto, S.; Monacelli, Piero; Morishima, Kunihiro; Moser, U.; Muciaccia, Maria Teresa; Naganawa, N.; Naka, T.; Nakamura, M.; Nakamura, T.; Nakano, T.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Osedlo, V.; Ossetski, D.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pilipenko, V.; Pistillo, C.; Polukhina, N.; Pozzato, M.; Pretzl, Klaus P.; Publichenko, P.; Pupilli, F.; Roganova, T.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryazhskaya, O.; Ryzhikov, D.; Sato, O.; Sato, Y.; Saveliev, V.; Sazhina, G.; Schembri, A.; Scotto Lavina, L.; Shibuya, H.; Simone, S.; Sioli, Max; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, Paolo Emilio; Sugonyaev, V.; Taira, Y.; Takahashi, S.; Tenti, M.; Terranova, F.; Tezuka, I.; Tioukov, V.; Tolun, P.; Tsarev, V.; Tufanli, S.; Ushida, N.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Wurtz, J.; Yoon, C.S.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, Amina; Zimmermann, R.

    2008-01-01

    New methods for efficient and unambiguous interconnection between electronic counters and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment, that aims at detecting oscillations between mu neutrino and tau neutrino in the CNGS neutrino beam, is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector, on-site large-scale treatments of the emulsions ("refreshing") have been applied. Changeable Sheet (CSd) packages, each made of a doublet of emulsion films, have been designed, assembled and coupled to the OPERA target units ("ECC bricks"). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronic...

  5. 基于ECC的移动自组网成员控制方案%Member Control Scheme of Mobile Ad Hoc Networks Based on ECC

    Institute of Scientific and Technical Information of China (English)

    耿永军; 陈红军; 郑明辉

    2012-01-01

    A distributed key generation protocol is proposed by ECC based on Peterson distributed key generation scheme, which can resist malicious attack of outer or inner node. A secure member control sckeme is also proposed by using threshold digital sisgnature. By analyzing the scheme's performance and security, a conclusion is drawn that the member control policy is suitable for mobile Ad Hoc networks of limited resource devices.%基于Pederson分布式密钥产生方案,采用椭圆曲线密码体制提出一个分布式密钥产生协议,该方案高效且能抵制内外恶意节点的攻击,并采用门限数字签名方案给出一个安全的移动自组网的成员控制方案.通过方案的性能和安全性分析得出结论,该成员控制策略非常适合于资源受限的移动自组网.

  6. Underground Injection Control (UIC)

    Science.gov (United States)

    Provide information on: individual injection well classes; regulations specific to each well class; technical guidance; compliance assistance; federal, state, and tribal/territory roles and responsibilities.

  7. Ferric Carboxymaltose Injection

    Science.gov (United States)

    ... pharmacist if you are allergic to ferric carboxymaltose injection, ferumoxytol (Feraheme), iron dextran (Dexferrum, Infed), iron sucrose (Venofer), or sodium ferric gluconate (Ferrlecit); any other ...

  8. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  9. Ryanodine receptor type 1 (RyR1) mutations C4958S and C4961S reveal excitation-coupled calcium entry (ECCE) is independent of sarcoplasmic reticulum store depletion.

    Science.gov (United States)

    Hurne, Alanna M; O'Brien, Jennifer J; Wingrove, Douglas; Cherednichenko, Gennady; Allen, Paul D; Beam, Kurt G; Pessah, Isaac N

    2005-11-04

    Bi-directional signaling between ryanodine receptor type 1 (RyR1) and dihydropyridine receptor (DHPR) in skeletal muscle serves as a prominent example of conformational coupling. Evidence for a physiological mechanism that upon depolarization of myotubes tightly couples three calcium channels, DHPR, RyR1, and a Ca(2+) entry channel with SOCC-like properties, has recently been presented. This form of conformational coupling, termed excitation-coupled calcium entry (ECCE) is triggered by the alpha(1s)-DHPR voltage sensor and is highly dependent on RyR1 conformation. In this report, we substitute RyR1 cysteines 4958 or 4961 within the TXCFICG motif, common to all ER/SR Ca(2+) channels, with serine. When expressed in skeletal myotubes, C4958S- and C4961S-RyR1 properly target and restore L-type current via the DHPR. However, these mutants do not respond to RyR activators and do not support skeletal type EC coupling. Nonetheless, depolarization of cells expressing C4958S- or C4961S-RyR1 triggers calcium entry via ECCE that resembles that for wild-type RyR1, except for substantially slowed inactivation and deactivation kinetics. ECCE in these cells is completely independent of store depletion, displays a cation selectivity of Ca(2+)>Sr(2+) approximately Ba(2+), and is fully inhibited by SKF-96365 or 2-APB. Mutation of other non-CXXC motif cysteines within the RyR1 transmembrane assembly (C3635S, C4876S, and C4882S) did not replicate the phenotype observed with C4958S- and C4961S-RyR1. This study demonstrates the essential role of Cys(4958) and Cys(4961) within an invariant CXXC motif for stabilizing conformations of RyR1 that influence both its function as a release channel and its interaction with ECCE channels.

  10. Nietzsche como destino da filosofia e da humanidade? interpretação contextual do § 1 do capítulo "por que sou um destino", de ecce homo

    OpenAIRE

    Stegmaier,Werner

    2010-01-01

    The following translation is a reduced and revised version of the paper Schicksal Nietzsche? Zu Nietzsches Selbsteinschätzung als Schicksal der Philosophie und der Menschheit (Ecce Homo, Warum ich ein Schicksal bin §1)" - originally published in Nietzsche-Studien 37 (2008) - which was specially prepared to be presented in lecture organized by the Grupo de Pesquisa Spinoza & Nietzsche (Spinoza & Nietzsche research group - SpiN), in the Universidade Federal do Rio de Janeiro (Rio de Jan...

  11. Hot carrier injection degradation under dynamic stress

    Institute of Scientific and Technical Information of China (English)

    Ma Xiao-Hua; Cao Yan-Rong; Hao Yue; Zhang Yue

    2011-01-01

    In this paper, we have studied hot carrier injection (HCI) under alternant stress. Under different stress modes, different degradations are obtained from the experiment results. The different alternate stresses can reduce or enhance the HC effect, which mainly depends on the latter condition of the stress cycle. In the stress mode A (DC stress with electron injection), the degradation keeps increasing. In the stress modes B (DC stress and then stress with the smallest gate injection) and C (DC stress and then stress with hole injection under Vg=0V and Vd = 1.8 V), recovery appears in the second stress period. And in the stress mode D (DC stress and then stress with hole injection under Vg = -1.8 V and Vd = 1.8 V), as the traps filled in by holes can be smaller or greater than the generated interface states, the continued degradation or recovery in different stress periods can be obtained.

  12. Application of Gaseous Sphere Injection Method for Modeling Under-expanded H2 Injection

    Energy Technology Data Exchange (ETDEWEB)

    Whitesides, R; Hessel, R P; Flowers, D L; Aceves, S M

    2010-12-03

    A methodology for modeling gaseous injection has been refined and applied to recent experimental data from the literature. This approach uses a discrete phase analogy to handle gaseous injection, allowing for addition of gaseous injection to a CFD grid without needing to resolve the injector nozzle. This paper focuses on model testing to provide the basis for simulation of hydrogen direct injected internal combustion engines. The model has been updated to be more applicable to full engine simulations, and shows good agreement with experiments for jet penetration and time-dependent axial mass fraction, while available radial mass fraction data is less well predicted.

  13. Design optimisation of a nanofluid injection system for LOCA events in a nuclear power plant

    Science.gov (United States)

    Călimănescu, I.; Stan, L. C.; Velcea, D. D.

    2016-08-01

    The safety issues inside a Nuclear Power Plant (NPP) are encompassing their capacity to ensure the heat sink, meaning the capacity of the systems to release the heat from the rector to the environment. The nanofluids having good heat transfer properties, are recommended to be used in such applications. The paper is solving the following scenario: considering the Safety Injection tank and the Nanofluid injection Tank, and considering the Nanofluid injection Tank filled with a 10% alumina-water nanofluid, how can we select the best design of the connecting point between the pipes of the SIT and the Nanofluid Tank and the pressures inside of any of these tanks in order to have the biggest density of nanoparticles leaving the tanks toward the cold leg. In conclusion the biggest influence over the rate of disposal of the nanofluid inside ECCS is that of the pressure inside the SIT followed in order by the injection pipe diameter and the pressure inside the nanofluid tank. The optimum balance of these three design parameters may be reached following the procedure shown in this paper.

  14. Influence of Injection and Cavity Pressure on the Demoulding Force in Micro-Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.G.

    2014-01-01

    of four process parameters, melt temperature, mould temperature, holding pressure, and injection speed, employing the design of experiment approach. In addition, the results obtained using different combinations of process parameters were analyzed to identify the best processing conditions in regards...

  15. [Intra-articular injections].

    Science.gov (United States)

    Chapelle, Ch

    2015-09-01

    It is not unusual for a specialist or general practitioner to be presented with a pathology which necessitates the use of an intra-articular injection of corticosteroids, hyaluronic acid or a local anaesthetic. It would seem to be interesting to update and to precise the techniques and methods of intraarticular injections which have appeared in recent international publications, when we know that 30 % of the injections given into the knee and so called "dry" are incorrect and, therefore, inefficient. The indication of an articular injection depends, firstly, on the diagnosis which should be done with great care; after which should be an objective analysis complete with secondary effects linked to both the injection and the product used. The conditions of asepsis, the choice of needles and quantities of the injection and even the ways of the injections should be reviewed in detail. The last studies clearly question the secondary effects of the cartilage degradations of the cortisone given as an intra-articular injection and shows its efficiency on the pain and inflammatory phenomonen in osteoarthritis. Studies on hyaluronic acid are often contradictory going from a modest result to an important pain relief but it is necessary to be aware that the objective criteria are difficult to interpret. The use of local anaesthetics in intra-articular is limited by the few indications in view of the major risk of aggravating the pre-existing lesions by the disappearing signs of pain.

  16. Injection of Deuterium Pellets

    DEFF Research Database (Denmark)

    Sørensen, H.; Andersen, P.; Andersen, S. A.

    1984-01-01

    A pellet injection system made for the TFR tokamak at Fontenay-aux-Roses, Paris is described. 0.12-mg pellets are injected with velocities of around 600-700 m/s through a 5-m long guide tube. Some details of a new light gas gun are given; with this gun, hydrogen pellets are accelerated...

  17. Corticotropin, Repository Injection

    Science.gov (United States)

    H.P. Acthar Gel® ... Corticotropin repository injection comes as a long acting gel to inject under the skin or into a ... prescription and nonprescription medications, vitamins, nutritional supplements, or herbal products you are taking or plan to take. ...

  18. Separably injective Banach spaces

    CERN Document Server

    Avilés, Antonio; Castillo, Jesús M F; González, Manuel; Moreno, Yolanda

    2016-01-01

    This monograph contains a detailed exposition of the up-to-date theory of separably injective spaces: new and old results are put into perspective with concrete examples (such as l∞/c0 and C(K) spaces, where K is a finite height compact space or an F-space, ultrapowers of L∞ spaces and spaces of universal disposition). It is no exaggeration to say that the theory of separably injective Banach spaces is strikingly different from that of injective spaces. For instance, separably injective Banach spaces are not necessarily isometric to, or complemented subspaces of, spaces of continuous functions on a compact space. Moreover, in contrast to the scarcity of examples and general results concerning injective spaces, we know of many different types of separably injective spaces and there is a rich theory around them. The monograph is completed with a preparatory chapter on injective spaces, a chapter on higher cardinal versions of separable injectivity and a lively discussion of open problems and further lines o...

  19. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    effects of DME in high pressure injection have also been observed. DME has a higher compressibility than diesel fuel, resulting in larger pressure oscillations in the injection system during the injection process. The oscillations with DME also have a slower delay rate than those of diesel fuel......A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump...... in the same system. As a first attempt to simulate combustion of DME in Diesel engines, the results of the spray studies have been incorporated into a simplified spray combustion model. A turbulent jet structure was adjusted to fit the penetration rates of the observed sprays. The observed spray widths agreed...

  20. Dependency injection with AngularJS

    CERN Document Server

    Knol, Alex

    2013-01-01

    This book is a practical, hands-on approach to using dependency injection and implementing test-driven development using AngularJS. Dependency Injection with AngularJS is aimed at developers who are aware of AngularJS but need to get started with using it in real life applications. Also, developers who want to get into test-driven development with AngularJS can use this book as practical guide. Even if you know about dependency injection, it can serve as a good reference on how it is used within AngularJS. Readers are expected to have some experience with JavaScript.

  1. An Improved Double-Gene Identity Authentication Protocol based on ECC%一种改进的基于ECC双因子身份认证协议

    Institute of Scientific and Technical Information of China (English)

    马丁; 马晓旭

    2013-01-01

    With the rapid development of information technology and network technology, the Internet real-name system now becomes an important trend of network supervision and management, while the user iden-tity authentication is the key to the real-name system. The identity authentication protocol based on smart-card is firstly described, and then the flaw of this protocol is discussed. With this, a double-gene identity authentication protocol based on ECC is proposed. And by using the elliptic curve discrete logarithm prob-lem and timestamp factor, the security of this protocol is ensured, the problem of smart-loss attack solved, and the high efficiency of the protocol maintained.%随着信息技术和网络技术的快速发展,互联网实名制已经成为网络监督和管理的重要趋势,而用户身份认证又是实名制管理体系中的关键技术。首先介绍了基于智能卡的身份认证协议,讨论了该协议存在的不足,并在此基础上,提出了一种基于ECC双因子的身份认证协议,通过椭圆曲线离散对数难题和时间戳因素确保协议的安全性,解决了丢失智能卡攻击的问题,并且保持了协议的高效性。

  2. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...... index of the nanostructured surfaces was estimated from atomic force micrographs and the theoretical reflectance was calculated using the transfer matrix method and effective medium theory. The measured reflectance shows good agreement with the theory of graded index antireflective nanostructures...

  3. ALICE Injected Beam Accidents

    CERN Document Server

    Appleby, R B

    2009-01-01

    The ALICE (point 2) interaction region is sensitive to beam orbit errors arising from magnet setting errors on injection. In this report, beam accident scenarios under injection for ALICE are described, focusing on ultra- fast error injection scenarios for the interaction straight correctors and dipoles. Beam 1 and beam 2 accident scenarios are considered, where the errors can lead to beam orbits striking the ALICE vacuum chamber or elements of the machine. The required thresholds for magnet current interlocks are calculated to avoid machine and detector risk.

  4. LHCb Injected Beam Accidents

    CERN Document Server

    Appleby, R B

    2009-01-01

    The LHCb (point 8) interaction region is sensitive to beam orbit errors arising from magnet setting errors on injection. In this report, beam accident scenarios under injection for LHCb are described, focusing on ultra- fast error injection scenarios for the interaction straight correctors and dipoles. Beam 1 and beam 2 accident scenarios are considered, where the errors can lead to beam orbits striking the LHCb vacuum chamber or elements of the machine. The required thresholds for magnet current interlocks are calculated to avoid machine and detector risk.

  5. Common injections in musculoskeletal medicine.

    Science.gov (United States)

    Monseau, Aaron J; Nizran, Parminder Singh

    2013-12-01

    Musculoskeletal injections are a common procedure in primary care and sports medicine but can be intimidating for some clinicians. This article addresses current evidence for corticosteroid injections, and common injection indications and techniques, namely knee, subacromial bursa, glenohumeral joint, lateral epicondyle, de Quervain tenosynovitis, and greater trochanteric bursa injections. Preparation for injections and some evidence for ultrasound guidance are also reviewed.

  6. Mouse bladder wall injection.

    Science.gov (United States)

    Fu, Chi-Ling; Apelo, Charity A; Torres, Baldemar; Thai, Kim H; Hsieh, Michael H

    2011-07-12

    Mouse bladder wall injection is a useful technique to orthotopically study bladder phenomena, including stem cell, smooth muscle, and cancer biology. Before starting injections, the surgical area must be cleaned with soap and water and antiseptic solution. Surgical equipment must be sterilized before use and between each animal. Each mouse is placed under inhaled isoflurane anesthesia (2-5% for induction, 1-3% for maintenance) and its bladder exposed by making a midline abdominal incision with scissors. If the bladder is full, it is partially decompressed by gentle squeezing between two fingers. The cell suspension of interest is intramurally injected into the wall of the bladder dome using a 29 or 30 gauge needle and 1 cc or smaller syringe. The wound is then closed using wound clips and the mouse allowed to recover on a warming pad. Bladder wall injection is a delicate microsurgical technique that can be mastered with practice.

  7. IncobotulinumtoxinA Injection

    Science.gov (United States)

    ... injected into a muscle, it blocks the nerve signals that cause uncontrollable tightening and movements of the ... any of these symptoms, do not drive a car, operate machinery, or do other dangerous activities.if ...

  8. Amphotericin B Liposomal Injection

    Science.gov (United States)

    ... lining of the spinal cord and brain) and visceral leishmaniasis (a parasitic disease that usually affects spleen, ... complex injection: fever, chills, nausea, vomiting, flushing, back pain with or without chest tightness, chest pain, shortness ...

  9. PS injection area

    CERN Multimedia

    1974-01-01

    To the right is the PS ring viewed along the direction of the protons. At the left the injection line coming from the 50 MeV Linac 1 (bottom) and going towards the 800 MeV booster, or deflected to the right to be injected directly into straight section 16. The drumlike element behind the (blue) dipole magnet is a 'debuncher' (a 200 MHz cavity). See photos 7409014X and 7409009.

  10. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  11. Quasi-stable injection channels in a wakefield accelerator

    Science.gov (United States)

    Wiltshire-Turkay, Mara; Farmer, John P.; Pukhov, Alexander

    2016-05-01

    The influence of initial position on the acceleration of externally injected electrons in a plasma wakefield is investigated. Test-particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the wake centre. Particles injected into these channels remain in the wake for a considerable time after dephasing and as a result achieve significantly higher energy than their neighbours. The result is relevant to both the planning and optimisation of experiments making use of external injection.

  12. Backfire prediction in a manifold injection hydrogen internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xing-hua; Liu, Fu-shui; Zhou, Lei; Sun, Bai-gang [School of Mechanical and Vehicular Engineering, Beijing Institute of Technology, Beijing 100081 (China); Schock, Harold J. [Engine Research Laboratory, Michigan State University, East Lansing, MI (United States)

    2008-07-15

    Hydrogen internal combustion engine (H2ICE) easily occur inlet manifold backfire and other abnormal combustion phenomena because of the low ignition energy, wide flammability range and rapid combustion speed of hydrogen. In this paper, the effect of injection timing on mixture formation in a manifold injection H2ICE was studied in various engine speed and equivalence ratio by CFD simulation. It was concluded that H2ICE of manifold injection have an limited injection end timing in order to prevent backfire in the inlet manifold. Finally, the limit of injection end timing of the H2ICE was proposed and validated by engine experiment. (author)

  13. Two-phase CFD PTS validation in an extended range of thermohydraulics conditions covered by the COSI experiment

    Energy Technology Data Exchange (ETDEWEB)

    Coste, P., E-mail: pierre.coste@cea.fr [CEA, DEN/DANS/DM2S/SMTF/LMSF, 17 rue des Martyrs, 38054 Grenoble (France); Ortolan, A. [CEA, DEN/DANS/DM2S/SMTF/LMSF, 17 rue des Martyrs, 38054 Grenoble (France); ENSICA Engineering School, Toulouse (France)

    2014-11-15

    Highlights: • Models for large interfaces in two-phase CFD were developed for PTS. • The COSI experiment is used for NEPTUNE{sub C}FD integral validation. • COSI is a PWR cold leg scaled 1/100 for volume. • Fifty runs are calculated, covering a large range of flow configurations. • The CFD predicting capability is analysed using global and local measurements. - Abstract: In the context of the Pressurized Water Reactors (PWR) life duration safety studies, some models were developed to address the Pressurized Thermal Shock (PTS) from the two-phase CFD angle, dealing with interfaces much larger than cells size and with direct contact condensation. Such models were implemented in NEPTUNE{sub C}FD, a 3D transient Eulerian two-fluid model. The COSI experiment is used for its integral validation. It represents a cold leg scaled 1/100 for volume and power from a 900 MW PWR under a large range of LOCA PTS conditions. In this study, the CFD is evaluated in the whole range of parameters and flow configurations covered by the experiment. In a first step, a single choice of mesh and CFD models parameters is fixed and justified. In a second step, fifty runs are calculated. The CFD predicting capability is analysed, comparing the liquid temperature and the total condensation rate with the experiment, discussing their dependency on the inlet cold liquid rate, on the liquid level in the cold leg and on the difference between co-current and counter-current runs. It is shown that NEPTUNE{sub C}FD 1.0.8 calculates with a fair agreement a large range of flow configurations related to ECCS injection and steam condensation.

  14. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation

    Directory of Open Access Journals (Sweden)

    Tolga Karakan

    2012-01-01

    Full Text Available Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  15. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  16. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  17. Fault Injection Techniques and Tools

    Science.gov (United States)

    Hsueh, Mei-Chen; Tsai, Timothy K.; Iyer, Ravishankar K.

    1997-01-01

    Dependability evaluation involves the study of failures and errors. The destructive nature of a crash and long error latency make it difficult to identify the causes of failures in the operational environment. It is particularly hard to recreate a failure scenario for a large, complex system. To identify and understand potential failures, we use an experiment-based approach for studying the dependability of a system. Such an approach is applied not only during the conception and design phases, but also during the prototype and operational phases. To take an experiment-based approach, we must first understand a system's architecture, structure, and behavior. Specifically, we need to know its tolerance for faults and failures, including its built-in detection and recovery mechanisms, and we need specific instruments and tools to inject faults, create failures or errors, and monitor their effects.

  18. Experiment on single well groundwater heat pump systems in different distances between pumping and injection screens%不同抽回间距的单井循环地下水源热泵系统试验

    Institute of Scientific and Technical Information of China (English)

    宋伟; 倪龙; 姚杨

    2014-01-01

    As the global energy crises and environmental problems become more and more serious, ground source heat pump (GSHP) systems are perhaps the most widely used green HVAC system, with an estimated 1.1 million ground source heat pumps installed worldwide. These systems have become an important energy-saving and environment protection technology for use in residential and commercial buildings in China. These applications included two types of systems: closed-loop (ground-coupled) and open-loop. As one kind of semi-closed-loop systems, single well groundwater heat pump (SWGWHP) systems have become increasingly popular for use because of their economic advantages from lower installation cost, lower operating cost, and improved overall performance in regions with suitable geological conditions. In general, SWGWHP systems included three different variations, i.e. standing column well (SCW) system, pumping & recharging well (PRW) system, and pumping&recharging well filled with gravel (PRWFG) system. Compared with SCW system, the well pipe in PRW system and PRWFG system are divided into three parts by clapboards, i.e. production zone, seals zone and injection zone. In recent decades, considerable research efforts have been spent on SWGWHP systems, especially on SCW system. However, little attention has been focused on the PRW system and PRWFG system. For GSHP systems, sand tank experiment is one of the important methods of laboratory investigation for discussing the performance of geothermal heat exchanger, due to many parameters can be set and adjusted more easily and economically than that in in-situ experiments. In order to provide a framework for discussing the influence on distances between pumping and injection screens (DPI) in SWGWHP systems, a sand tank experiment system was designed and set up in Harbin Institute of Technology, China. In this study, we tested the temperature of outlet and inlet water, the aquifer temperature, and flow rate of outlet water. From the

  19. 3G视频会议系统中的ECC快速算法研究%Study on ECC High-speed Algorithm in 3G Video Conference System

    Institute of Scientific and Technical Information of China (English)

    吴松洋; 武海鹰; 卢忱

    2011-01-01

    3G video conferencing system, due to its restrictions by open wireless networks, is difficult to meet the specific security requirement of the industry customers. The existing 3G video conferencing systems have many technical difficulties in encryption, one of which is high hardware requirement by conventional encryption algorithm, and large latency. ECC encryption algorithm wit a better adaptability to the requirements of 3G video terminal equipment is an applicable encryption algorithm. Based on this application, the ECC algorithm is further optimized, and thus could better adapt to the requirement of 3G video conferencing terminal. This paper proposes a fast algorithm based on ECC, which is proven to he effective in reducing resource requirement, raising operation speed, and thus up to the application requirement.%3G视频会议系统由于受到无线网络开放性的限制,难以满足行业客户的特殊安全需求。现有3G视频会议系统的加密存在着诸多技术困难,其一就是常规加密算法对硬件要求高,时延较大。ECC加密算法可以较好地适应3G视频终端设备的要求,是一种可行的加密算法。针对此应用对ECC算法做进一步的优化能更好地适应3G视频会议系统终端的需求。文章提出了一种基于ECC的快速算法,经证明可以有效降低资源需求,提高速度,达到应用要求。

  20. Demonstration of steady inductive helicity injection

    Science.gov (United States)

    Sieck, P. E.; Jarboe, T. R.; Izzo, V. A.; Hamp, W. T.; Nelson, B. A.; O'Neill, R. G.; Redd, A. J.; Smith, R. J.

    2006-02-01

    Initial results demonstrating the concept of constant inductive helicity injection are presented. Constant helicity injection is achieved using two oscillating inductive helicity injectors, with the goal of producing a bow tie spheromak. Each injector is a 180° segment of a reverse field pinch and they are driven 90° out of phase. Approximately 5 MW of power is injected during the 6 ms pulse, and the input power has been maintained at a fairly constant value by directly fuelling the injectors with neutral gas. Motivation for the experiment is given, including beta-limit calculations for the bow tie spheromak. Fuelling the injectors with neutral gas during the discharge is shown to produce injector parameters that are more constant in time. A series of discharges with increasing power input shows a promising increase in toroidal current. Unique construction techniques of the experiment are also described.

  1. El Espacio de Coordinación de Centro (ECC) del Campus Virtual como plataforma para la orientación, el asesoramiento y la tutorización de estudiantes

    OpenAIRE

    Gómez Gómez, Francisco; Munuera Gómez, Pilar

    2007-01-01

    Daremos cuenta de lo planificado en el Proyecto de Innovación y Mejora de la Calidad Docente: «Tutorías, asesoramiento y orientación de los estudiantes mediante el Espacio de Coordinación de Centro (ECC) del Campus Virtual (CV) de la Universidad Complutense de Madrid (UCM)» y desarrollaremos brevemente lo realizado en tal ámbito con los 54 estudiantes matriculados en el curso académico 2005-06 en la segunda especialidad en «Orientación y consejería al niño, adolescente y psicotera...

  2. El Espacio de Coordinación de Centro (ECC) del Campus Virtual (CV) como plataforma para la orientación, el asesoramiento y la tutorización de estudiantes

    OpenAIRE

    Gómez Gómez, Francisco; Munuera Gómez, Pilar

    2007-01-01

    Daremos cuenta de lo planificado en el Proyecto de Innovación y Mejora de la Calidad Docente: “Tutorías, asesoramiento y orientación de los estudiantes mediante el Espacio de Coordinación de Centro (ECC) del Campus Virtual (CV) de la Universidad Complutense de Madrid (UCM)” y desarrollaremos brevemente lo realizado en tal ámbito con los 54 estudiantes matriculados, en el curso académico 2005-06, en la segunda especialidad en “Orientación y consejería al niño, adolescente y psicoterapia famili...

  3. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.;

    2010-01-01

    has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been...

  4. Analysis of ROSA 1.1 test with TRACE code: ECSS water injection under natural circulation conditions; Analisis con el codigo TRACE del test ROSA 1.1: Inyeccion de agua ECCS bajo condiciones de circulacion natural

    Energy Technology Data Exchange (ETDEWEB)

    Julibe, A. J.; Munoz-Coba, J. L.; Escriva, A.; Romero, A.

    2010-07-01

    This paper is based on modelling the ROSA 1.1 test by TRACE code. The ROSA 1.1 test presents several natural flow phases in biphasic conditions and this was the cause of this work. Therefore, the aim of this paper is verify the TRACE code ability to simulate such flows using standard components and modules.

  5. Intracytoplasmic Sperm Injection (ICSI)

    Science.gov (United States)

    ... sperm must attach to the outside of the egg. Once attached, the sperm pushes through the outer layer to the inside ... in vitro fertilization (IVF) to help fertilize the egg. During ICSI, a single sperm is injected directly into the cytoplasm the egg. ...

  6. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  7. Giving an insulin injection

    Science.gov (United States)

    ... an alcohol wipe on your injection site. The insulin needs to go into the fat layer under the skin. Pinch the skin and put the needle in at a 45º angle. If your tissues are thick enough, you may be able to ...

  8. Study of the effects induced by lead on the emulsion films of the OPERA experiment

    CERN Document Server

    Patrizii, L; Aoki, S; Ariga, A; Arrabito, L; Autiero, D; Badertscher, A; Bay, F; Bergnoli, A; Bersani Greggio, F; Besnier, M; Bick, D; Bozza, C; Brugiere, T; Brugnera, R; Brunetti, G; Buontempo, S; Carrara, E; Cazes, A; Chaussard, L; Chernyavsky, M; Chiarella, V; Chon-Sen, N; Chukanov, A; Consiglio, L; Cozzi, M; Dal Corso, F; D'Amato, G; D'Ambrosio, N; De Lellis, G; Declais, Y; De Serio, M; Di Capua, F; Di Ferdinando, D; Di Giovanni, A; Di Marco, N; Di Troia, C; Dmitrievski, S; Dominjon, A; Dracos, M; Duchesneau, D; Dulach, B; Dusini, S; Ebert, J; Egorov, O; Enikeev, R; Ereditato, A; Esposito, L S; Favier, Jean; Felici, G; Ferber, T; Fini, R; Franceschi, A; Fukuda, T; Fukushima, C; Galkin, V I; Galkin, V A; Garfagnini, A; Giacomelli, G; Giorgini, M; Goellnitz, C; Golubkov, D; Gornoushkin, Y; Grella, G; Grianti, F; Güler, M; Gusev, G; Gustavino, C; Hagner, C; Hara, T; Hierholzer, M; Hiramatsu, S; Hoshino, K; Ieva, M; Jakovcic, K; Janicsko, C; sathy, J; Janutta, B; Jollet, C; Juget, F; Kawai, T; Kazuyama, M; Kim, S H; Kimura, M; Knuesel, J; Kodama, K; Komatsu, M; Köse, U; Kreslo, I; Laktineh, I; Lazzaro, C; Lenkeit, J; Ljubicic, A; Longhin, A; Lutter, G; Manai, K; Mandrioli, G; Manzoor, S; Marotta, A; Marteau, J; Matsuoka, H; Mauri, N; Meisel, F; Meregaglia, A; Messina, M; Migliozzi, P; Miyamoto, S; Monacelli, P; Morishima, K; Moser, U; Muciaccia, M T; Naganawa, N; Naka, T; Nakamura, M; Nakamura, T; Nakano, T; Nikitina, V; Niwa, K; Nonoyama, Y; Ogawa, S; Osedlo, V; Ossetski, D; Paoloni, A; Park, B D; Park, I G; Pastore, A; Pennacchio, L; Patrizii, E; Pessard, H; Pistillo, C; Polukhina, N; Pozzato, M; Publichenko, P; Pupilli, F; Roganova, T; Rosa, G; Rostovtseva, I; Rubbia, K; Pretzl, A; Russo, A; Ryazhskaya, O; Ryzhikov, D; Sato, Y; Sato, O; Saveliev, V; Sazhina, G; Schembri, A; Scotto-Lavina, L; Shibuya, H; Simone, S; Sioli, M; Sirignano, C; Sirri, G; Song, J S; Spinetti, M; Stanco, L; Starkov, N; Stipcevic, M; Strauss, T; Strolin, P; Sugonyaev, V; Taira, Y; Takahashi, S; Tenti, M; Terranova, F; Tioukov, V; Togo, V; Tolun, P; Tsarev, V; Tufanli, S; Ushida, N; Valieri, C; Vilain, P; Vladimirov, M; Votano, L; Vuilleumier, J L; Wilquet, G; Wonsak, B; Wurtz, J; Yoon, C S; Yoshida, J; Zaitsev, Y; Zemskova, S; Zghiche, A; Zimmermann, R

    2008-01-01

    The OPERA neutrino oscillation experiment is based on the use of the Emulsion Cloud Chamber (ECC). In the OPERA ECC, nuclear emulsion films acting as very high precision tracking detectors are interleaved with lead plates providing a massive target for neutrino interactions. We report on studies related to the effects occurring from the contact between emulsion and lead. A low radioactivity lead is required in order to minimize the number of background tracks in emulsions and to achieve the required performance in the reconstruction of neutrino events. It was observed that adding other chemical elements to the lead, in order to improve the mechanical properties, may significantly increase the level of radioactivity on the emulsions. A detailed study was made in order to choose a lead alloy with good mechanical properties and an appropriate packing technique so as to have a low enough effective radioactivity.

  9. Computational Study of Combustion Dynamics in a Single-Element Lean Direct Injection Gas Turbine Combustor

    Science.gov (United States)

    2013-12-01

    spray injection models , viz., Log Normal Distributed Drop Injection Model , Single Drop Injection Model and Hollow Cone Injection Model , have...not match experiment. The hollow cone injection model was able to predict the correct dominant acoustic mode (4L) but the pressure amplitude was...processes of pressure-swirl hollow - cone fuel sprays ," Atomization and Sprays , vol. 7, pp. 663-684, Nov-Dec 1997. 22 M. A. Patterson and R. D.

  10. Cavity Pressure Behaviour in Micro Injection Moulding

    DEFF Research Database (Denmark)

    Griffiths, C.A.; Dimov, S.S.; Scholz, S.

    2010-01-01

    Process monitoring of micro injection moulding (µIM) is of crusial importance to analyse the effect of different parameter settings on the process and to assess its quality. Quality factors related to cavity pressure can provide useful information directly connected with the dyanmics of the process...... has been investigated by moulding a micro fluidic component on three different polymers (PP, ABS, PC) using the design of experiment approach. Similar trends such as the effects of a higher injection speed in decreasing the pressure work and of a lower temperature in decreasing pressure rate have been...

  11. TECHNOLOGICAL WASTE DISPOSAL BY SUBSURFACE INJECTION TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Janković Branimir

    2002-12-01

    Full Text Available The application of oilfield and solution mining technology to subsurface disposal of technological wastes has proven to be an environmentally, technically and economically suitable method for the disposal of the waste generated in petroleum industry as well as other industrial branches. This paper describes the subsurface injection technology, the disposal formation characteristics, the waste disposal well design, evaluates the environmental impact of above mentioned technology and proposes a solutions for disposing of technological wastes in Croatia or nerby region by implementing underground injection technology according to the world experience (the paper is published in Croatian.

  12. Effect of Functional Nano Channel Structures Different Widths on Injection Molding and Compression Molding Replication Capabilities

    DEFF Research Database (Denmark)

    Calaon, M.; Tosello, G.; Garnaes, J.

    The present study investigates the capabilities of the two employed processes, injection molding (IM) and injection compression molding (ICM) on replicating different channel cross sections. Statistical design of experiment was adopted to optimize replication quality of produced polymer parts wit...

  13. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  14. SPS injection kicker magnet

    CERN Multimedia

    1975-01-01

    One of the first-generation SPS injection kicker magnets, view of the complete tank. First proton beam from the PS was injected into the SPS in 1976, at a beam momentum of 10 GeV/c. These kickers served until the end of 1979 and were replaced at the beginning of 1980 by stronger ones, in preparation for the SPS as a proton-antiproton collider. For this, transfer momentum from the PS to the SPS was raised to 26 GeV/c, so as to avoid acceleration of the dense p and pbar bunches through SPS transition energy. Bearded Roland Tröhler is at the left, Giacomo Busetta smiles at the right. See also 7502073X, 7502074X and Annual Report 1975, 162.

  15. Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience; Angiografia rotazionale tridimensionale delle carotidi mediante iniezione ad alto flusso dell'arco aortico. Esperienza preliminare

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi Mucelli, Fabio; Calgaro, Antonio; Bruni, Stefano; Bottaro, Lorella; Pozzi Mucelli, Roberto [Trieste Univ., Trieste (Italy). Unita' Clinico Operativa di Radiologia

    2005-02-01

    Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded Surface Display), automatically remove bone structures (cervical spine, calcified plaque, etc) and perform an automatic analysis of the vessel diameter and surface area at the point of major stenosis and in the disease-free vessel segments above and below. The carotid evaluation was done either with selective catheterization and the two standard AP and LL projections and with RA after contrast medium injection from the aortic arch followed by 3D reconstruction. Results: The comparison of the selective angiography and three-dimensional images was possible in 37 out of 40 carotid bifurcations (3 internal carotid arteries were occluded) and a good diagnostic quality was obtained in 35 out of 37 cases with an high correlation in the degree of stenosis. In 2/37 cases with calcified plaques the degree of stenosis was effectively demonstrated only after electronic subtraction of the calcified component of the plaque. Conclusions: The technique we propose proved to be feasible in all cases with a good correlation

  16. PS injection area

    CERN Multimedia

    1974-01-01

    Looking against the direction of protons in the main ring (left): the beam coming from the linac 1 either goes to the booster (on the right) or is deflected towards the PS to be directly injected into section 26 (facing the camera). Also shown the start of the TT2 line, ejected from straight section 16 to go towards the ISR passing over the beam line from the linac. (see Photo Archive 7409009)

  17. Injection-induced earthquakes.

    Science.gov (United States)

    Ellsworth, William L

    2013-07-12

    Earthquakes in unusual locations have become an important topic of discussion in both North America and Europe, owing to the concern that industrial activity could cause damaging earthquakes. It has long been understood that earthquakes can be induced by impoundment of reservoirs, surface and underground mining, withdrawal of fluids and gas from the subsurface, and injection of fluids into underground formations. Injection-induced earthquakes have, in particular, become a focus of discussion as the application of hydraulic fracturing to tight shale formations is enabling the production of oil and gas from previously unproductive formations. Earthquakes can be induced as part of the process to stimulate the production from tight shale formations, or by disposal of wastewater associated with stimulation and production. Here, I review recent seismic activity that may be associated with industrial activity, with a focus on the disposal of wastewater by injection in deep wells; assess the scientific understanding of induced earthquakes; and discuss the key scientific challenges to be met for assessing this hazard.

  18. Injection-induced earthquakes

    Science.gov (United States)

    Ellsworth, William L.

    2013-01-01

    Earthquakes in unusual locations have become an important topic of discussion in both North America and Europe, owing to the concern that industrial activity could cause damaging earthquakes. It has long been understood that earthquakes can be induced by impoundment of reservoirs, surface and underground mining, withdrawal of fluids and gas from the subsurface, and injection of fluids into underground formations. Injection-induced earthquakes have, in particular, become a focus of discussion as the application of hydraulic fracturing to tight shale formations is enabling the production of oil and gas from previously unproductive formations. Earthquakes can be induced as part of the process to stimulate the production from tight shale formations, or by disposal of wastewater associated with stimulation and production. Here, I review recent seismic activity that may be associated with industrial activity, with a focus on the disposal of wastewater by injection in deep wells; assess the scientific understanding of induced earthquakes; and discuss the key scientific challenges to be met for assessing this hazard.

  19. Combined pre-injection wrist and ankle MRI protocol and steroid joint injections in juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kan, J.H. [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Graham, T.B. [Monroe Carell Jr. Children' s Hospital at Vanderbilt, Department of Pediatric Rheumatology, Nashville, TN (United States)

    2011-10-15

    Precise localization of affected compartments of the wrist and ankle in children with an established diagnosis of juvenile idiopathic arthritis (JIA) is clinically challenging. The purpose of this paper is to describe our experience utilizing a pre-injection MRI protocol of the wrist and ankle for localizing disease activity followed by fluoroscopically guided joint injections in children with JIA. (orig.)

  20. Report and Analysis of the May 1979 Marine Surface Layer Micrometeorological Experiment at San Nicolas Island, California.

    Science.gov (United States)

    1981-12-31

    and the topic of horizontal homo - geneity of the marine boundary layer is discussed. -The experiment data base is to be made available on magnetic...EuC~~UC, E, -4) 0 .C,, 0 r- E ECC - - 0m C). ’A U0 r4 C4 M W5 U U C Cx 0 C-11 5 - n - : 0 : U~ CuU ~,~~C(U U E 260 -. NRL REPORT 8363 with a Particle

  1. Quasi-stable injection channels in a wakefield accelerator

    CERN Document Server

    Wiltshire-Turkay, Mara; Pukhov, Alexander

    2016-01-01

    Particle-driven plasma-wakefield acceleration is a promising alternative to conventional electron acceleration techniques, potentially allowing electron acceleration to energies orders of magnitude higher than can currently be achieved. In this work we investigate the dependence of the energy gain on the position at which electrons are injected into the wake. Test particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the centre of the wake. The result is relevant to the planning and tuning of experiments making use of external injection.

  2. Ultrafast and Gigantic Spin Injection in Semiconductors

    Science.gov (United States)

    Battiato, M.; Held, K.

    2016-05-01

    The injection of spin currents in semiconductors is one of the big challenges of spintronics. Motivated by the ultrafast demagnetization and spin injection into metals, we propose an alternative femtosecond route based on the laser excitation of superdiffusive spin currents in a ferromagnet such as Ni. Our calculations show that even though only a fraction of the current crosses the Ni-Si interface, the laser-induced creation of strong transient electrical fields at a ferromagnet-semiconductor interface allows for the injection of chargeless spin currents with record spin polarizations of 80%. Beyond that they are pulsed on the time scale of 100 fs which opens the door for new experiments and ultrafast spintronics.

  3. Residual stress distribution in injection molded parts

    Directory of Open Access Journals (Sweden)

    P. Postawa

    2006-08-01

    Full Text Available Purpose: The paper presents the results of the investigations of influence of the amorphous polystyrene (PSprocessing on the diversity of the internal stresses observed in the injection moulded piece.Design/methodology/approach: For the tests, the standardized mould piece designed for the investigations ofthe processing shrinkage of thermoplastics materials has been used. The samples have been prepared using theDesign of Experiment (DoE theory.The state of internal stresses has been analysed by means of photoelastic method (used stress viewer equipmenton the basis of the layout and size of the isochromatics (fields with the same colour, which determine the mouldpiece’s areas where the same value for the difference of main tensions. In the article the results of investigationsof influence of 5 chosen processing parameters such as injection temperature Tw, mould temperature Tf,clamping pressure pd, cooling time tch and the injection speed vw on the changes in isochromatics layout as adeterminant for diversity of internal stresses in injection moulded pieces have been presented.Findings: The performed investigations of the influence of injection conditions on the state of internal stressesreached for injection mould pieces were to determine the parameters of injection at which the achieved state ofthe stresses in the mould piece (described by the difference of main tensions will show the lowest values.Practical implications: Effects of examinations of influence of processing conditions on residual stress ininjection molded parts (presented in the article could find practical application in polymer industry, both smalland large enterprises.Originality/value: New approach to fast estimation of value of residual stresses were present in the paper.

  4. Steroid injections - tendon, bursa, joint

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007678.htm Steroid injections - tendon, bursa, joint To use the sharing features on ... painful. It can be injected into a joint, tendon, or bursa. Description Your health care provider inserts ...

  5. Amphotericin B Lipid Complex Injection

    Science.gov (United States)

    Amphotericin B lipid complex injection is used to treat serious, possibly life-threatening fungal infections in people who did not respond ... to tolerate conventional amphotericin B therapy. Amphotericin B lipid complex injection is in a class of medications ...

  6. Injection treatments for patellar tendinopathy

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; van den Akker-Scheek, Inge

    2011-01-01

    Objective Injection treatments are increasingly used as treatment for patellar tendinopathy. The aim of this systematic review is to describe the different injection treatments, their rationales and the effectiveness of treating patellar tendinopathy. Methods A computerised search of the Medline,

  7. Parametric Studies of Flow Separation using Air Injection

    Science.gov (United States)

    Zhang, Wei

    2004-01-01

    Boundary Layer separation causes the airfoil to stall and therefore imposes dramatic performance degradation on the airfoil. In recent years, flow separation control has been one of the active research areas in the field of aerodynamics due to its promising performance improvements on the lifting device. These active flow separation control techniques include steady and unsteady air injection as well as suction on the airfoil surface etc. This paper will be focusing on the steady and unsteady air injection on the airfoil. Although wind tunnel experiments revealed that the performance improvements on the airfoil using injection techniques, the details of how the key variables such as air injection slot geometry and air injection angle etc impact the effectiveness of flow separation control via air injection has not been studied. A parametric study of both steady and unsteady air injection active flow control will be the main objective for this summer. For steady injection, the key variables include the slot geometry, orientation, spacing, air injection velocity as well as the injection angle. For unsteady injection, the injection frequency will also be investigated. Key metrics such as lift coefficient, drag coefficient, total pressure loss and total injection mass will be used to measure the effectiveness of the control technique. A design of experiments using the Box-Behnken Design is set up in order to determine how each of the variables affects each of the key metrics. Design of experiment is used so that the number of experimental runs will be at minimum and still be able to predict which variables are the key contributors to the responses. The experiments will then be conducted in the 1ft by 1ft wind tunnel according to the design of experiment settings. The data obtained from the experiments will be imported into JMP, statistical software, to generate sets of response surface equations which represent the statistical empirical model for each of the metrics as

  8. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  9. EFFECTIVENESS OF CELLULAR INJECTION MOLDING PROCESS

    Directory of Open Access Journals (Sweden)

    Tomasz Garbacz

    2013-06-01

    Full Text Available In a study of cellular injection, molding process uses polyvinylchloride PVC. Polymers modified with introducing blowing agents into them in the Laboratory of the Department of Technologies and Materiase of Technical University of Kosice. For technological reasons, blowing agents have a form of granules. In the experiment, the content of the blowing agent (0–2,0 % by mass fed into the processed polymer was adopted as a variable factor. In the studies presented in the article, the chemical blowing agents occurring in the granulated form with a diameter of 1.2 to 1.4 mm were used. The view of the technological line for cellular injection molding and injection mold cavity with injection moldings are shown in Figure 1. The results of the determination of selected properties of injection molded parts for various polymeric materials, obtained with different content of blowing agents, are shown in Figures 4-7. Microscopic examination of cross-sectional structure of the moldings were obtained using the author's position image analysis of porous structure. Based on analysis of photographs taken (Figures 7, 8, 9 it was found that the coating containing 1.0% of blowing agents is a clearly visible solid outer layer and uniform distribution of pores and their sizes are similar.

  10. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  11. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Science.gov (United States)

    2017-01-01

    We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS) microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI) technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE) separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method. PMID:28326222

  12. 高韧性纤维增强水泥基复合材料与老混凝土的界面直剪试验研究%Experiment and Study on Direct Shear Behavior for Adhesion of Fiber Reinforced High Ductility Cementitious Composites on Existing Concrete

    Institute of Scientific and Technical Information of China (English)

    邓宗才; 薛会青

    2011-01-01

    Fiber reinforced high ductility cementitious composites(ECC) has high ductility and could effectively control micro-crack width. The experiment of direct shear behavior is researched for adhesion of ECC on existing concrete and provides records for retrofitting or strengthening concrete. Experimental results show that compressive and flexural strength of ECC are improved with increase of age; Interface shear strength of ECC bonding specimens is improved with increase of S/C, indicating the behavior of adhesion of ECC on existing concrete is improved with increase of S/C; The behavior of adhesion of ECC on existing concrete is much better than on self-compacting concrete and plain concrete. ECC is perfect material for retrofitting deck and pavement, strengthening reservoir and dam.%高韧性纤维增强水泥基复合材料(ECC)具备很好的延展性和微裂缝宽度控制能力,通过ECC与老混凝土之间的界面直剪试验,研究高韧性复合材料与普通混凝土之间的界面黏结性能,为混凝土工程的维修或加固提供试验数据.试验结果表明:随着龄期的增加,ECC抗压强度与抗折强度逐渐提高;随着砂灰比的增加,ECC黏结试件的界面抗剪强度逐渐提高,说明增加砂灰比可以提高ECC与老混凝土间的界面黏结性能;ECC与老混凝土间的界面黏结性能远优于自密实混凝土和普通混凝土,高韧性水泥基复合材料是修补桥面、路面和加固水库、大坝等混凝土工程的理想材料.

  13. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  14. MKI UFOs at Injection

    CERN Document Server

    Baer, T; Bartmann, W; Bracco, C; Carlier, E; Chanavat, C; Drosdal, L; Garrel, N; Goddard, B; Kain, V; Mertens, V; Uythoven, J; Wenninger, J; Zerlauth, M

    2011-01-01

    During the MD, the production mechanism of UFOs at the injection kicker magnets (MKIs) was studied. This was done by pulsing the MKIs on a gap in the circulating beam, which led to an increased number of UFOs. In total 43 UFO type beam loss patterns at the MKIs were observed during the MD. The MD showed that pulsing the MKIs directly induces UFO type beam loss patterns. From the temporal characteristics of the loss profile, estimations about the dynamics of the UFOs are made.

  15. A Secure Signature Scheme for Wireless Body Area Networks Based on Network Coding and ECC Algorithm%基于网络编码和ECC的无线体域网安全签名方案

    Institute of Scientific and Technical Information of China (English)

    蒙云番; 孙光昊; 邢杰; 万海斌; 覃团发

    2015-01-01

    Security challenges in wireless body area networks ( WBAN) have been paid unprecedented at-tention for the vulnerable of patient’s personal sensitive data. In order to address prevalent security con-cerns,a secure signature scheme based on network coding and elliptic curve cryptography( ECC) algorithm is proposed. The scheme firstly introduces network coding to establish a multicast model in WBAN. The en-ergy efficiency of the network increases as more volume of data will be transmitted to the sink with the same number of transmissions. Through signing the packets by utilizing ECC algorithm,secure communication of patient-related physiological data is possible in hostile environments. The scheme includes three phases,i. e. ,setup,signature and verification. Data simulation proves that the scheme is secure,simultaneously pro-vides authentication and detects malicious nodes that intentionally corrupt content on the network.%针对无线体域网( WBAN)应用中人们关注的病患个人敏感数据在传输过程中容易受到攻击的安全问题,提出一种结合随机网络编码和椭圆曲线密码学( ECC)的安全签名方案。该方案首先在网络中引入随机网络编码建立多播网络模型,增加相同传输次数下的数据信息量;通过采用ECC算法对信息进行签名,保障病患相关生理信息的通信安全。该方案共有三个阶段,即创建、签名和验证阶段。理论证明了该方案是安全的,能够有效地对信息进行污染验证,并确定受攻击节点的位置。

  16. 小切口ECCE加loL植入在晶状体溶解性青光眼中的应用%Application of ECCE combined with loL implantation in small incision phacolytic glaucoma

    Institute of Scientific and Technical Information of China (English)

    樊奕秋; 熊世玉

    2013-01-01

    目的:浅析小切口ECCE加loL植入在晶状体溶解性青光眼中的应用。方法:按照临床治疗方式的不同,将患有晶状体溶解性青光眼的患者分为实验组和对照组,进行手术治疗。其中实验组行小切口ECCE加loL植入治疗,对照组行常规治疗,比较两组治疗疗效。结果:经过手术,实验组患有晶状体溶解性青光眼的患者角膜透明,瞳孔居中,没有出现不良反应,视力均得到不同程度提高;对照组患有晶状体溶解性青光眼的患者中有6例患者的手术失败,并出现了不良反应,其中2例最终摘除眼球。结论:在手术中,小切口ECCE加loL植入的技术,对患有晶状体溶解性青光眼的患者具有明显效果,适用于治疗晶状体溶解性青光眼的手术中。%Objective :the application of ECCE and loL implantation in small incision in the purpose of phacolytic glaucoma .Methods :according to clinical treatment in different ways ,will suffer fromphacolytic glaucoma were divided into experimental group and control group ,treatment of opera-tion .The experimental groupunderwent small incision ECCE plus loL implantation in the treatment ,the control group received routine therapy ,thera-peutic efficacy was compared between the two groups .Results:after the operation ,the experimental group withphacolytic glaucoma patients cornea was transparent ,the pupilcenter ,no adverse reaction ,visual acuity was improved to different extent ;the control group with phacolytic glaucomapa-tients failed in operation in 6 patients ,and the emergence ofadverse reactions ,including 2 cases of final enucleation of eyeball .Conclusion:in opera-tion ,small incision ECCE plus loLembedded technology ,has obvious effect on the patients withphacolytic glaucoma patients ,suitable for the treat-ment ofphacolytic glaucoma operation .

  17. The effect of injection pressure and fuel viscosity on the spray characteristics of biodiesel blends injected into an atmospheric chamber

    Energy Technology Data Exchange (ETDEWEB)

    Ghurri, Ainul; Kim, Jae Duk; Kim, Hyung Gon; Jung, Jae Youn; Song, Kyu Keun [Chonbuk National Univ., Deokjin Gu (Korea, Republic of)

    2012-09-15

    An experimental study was conducted to examine the effect of injection pressure and fuel type on the spray tip penetration length and the angle of spray injected into atmospheric chamber. The objective of the present study is to formulate empirical correlations of the spray tip penetration and the spray angle for non evaporative condition. The experiment was performed by a common rail type high pressure injector for the diesel engine at the injection pressure 40{approx}100 MPa and four different fuels (D100, BD25, BD45, and BD65). The results showed that the biodiesel content increased the spray tip penetration and decreased the spray angle. The correlation of spray tip penetration is expressed for each region before and after spray break up time in terms of injection pressure, fuel viscosity and time after start of injection. The correlation is also obtained for spray angle equation terms of injection pressure and fuel viscosity.

  18. Evaluation of the impact of viscosity, injection volume, and injection flow rate on subcutaneous injection tolerance

    Directory of Open Access Journals (Sweden)

    Berteau C

    2015-11-01

    Full Text Available Cecile Berteau,1 Orchidée Filipe-Santos,1 Tao Wang,2 Humberto E Rojas,2 Corinne Granger,1 Florence Schwarzenbach1 1Becton-Dickinson Medical Pharmaceutical Systems, Le Pont de Claix, France; 2Eli Lilly and Company, Indianapolis, IN, USA Aim: The primary objective of this study was to evaluate the impact of fluid injection viscosity in combination with different injection volumes and flow rates on subcutaneous (SC injection pain tolerance. Methods: The study was a single-center, comparative, randomized, crossover, Phase I study in 24 healthy adults. Each participant received six injections in the abdomen area of either a 2 or 3 mL placebo solution, with three different fluid viscosities (1, 8–10, and 15–20 cP combined with two different injection flow rates (0.02 and 0.3 mL/s. All injections were performed with 50 mL syringes and 27G, 6 mm needles. Perceived injection pain was assessed using a 100 mm visual analog scale (VAS (0 mm/no pain, 100 mm/extreme pain. The location and depth of the injected fluid was assessed through 2D ultrasound echography images. Results: Viscosity levels had significant impact on perceived injection pain (P=0.0003. Specifically, less pain was associated with high viscosity (VAS =12.6 mm than medium (VAS =16.6 mm or low (VAS =22.1 mm viscosities, with a significant difference between high and low viscosities (P=0.0002. Target injection volume of 2 or 3 mL was demonstrated to have no significant impact on perceived injection pain (P=0.89. Slow (0.02 mL/s or fast (0.30 mL/s injection rates also showed no significant impact on perceived pain during SC injection (P=0.79. In 92% of injections, the injected fluid was located exclusively in SC tissue whereas the remaining injected fluids were found located in SC and/or intradermal layers. Conclusion: The results of this study suggest that solutions of up to 3 mL and up to 15–20 cP injected into the abdomen within 10 seconds are well tolerated without pain. High

  19. On L-injective Covers

    Institute of Scientific and Technical Information of China (English)

    周德旭

    2004-01-01

    We use the class of L-injective modules to define L-injective covers, and provide the characterizations of L-injective covers by the properties of kernels of homomorphisms. We prove that the right L-noetherian right L-hereditary ring is just such that every right R-module has an L-injective cover which is monic. We also use kernels of homomorphisms to investigate L-simple L-injective covers and give some constructions ofL-simple L-iniective covers.

  20. Flow Injection Analysis

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    2004-01-01

    This chapter provides an introduction to automated chemical analysis, which essentially can be divided into two groups: batch assays, where the solution is stationary while the container is moved through a number of stations where various unit operations performed; and continuous-flow procedures,......, but it permits thr execution of novel and unique analytical procedures which are difficult or even impossible by conventional means. The performance and applicability of FIA, SI and LOV are illustrated by a series of practical examples.......This chapter provides an introduction to automated chemical analysis, which essentially can be divided into two groups: batch assays, where the solution is stationary while the container is moved through a number of stations where various unit operations performed; and continuous-flow procedures......, where the system is stationary while the solution moves through a set of conduits in which all required manipulations are performed. Emphasis is placed on flow injection analysis (FIA) and its further developments, that is, sequential injection analysis (SIA) and the Lab-on-Valve (LOV) approach. Since...

  1. Epidemiology of Injection Drug Use

    Science.gov (United States)

    Arruda, Nelson; Bruneau, Julie; Jutras-Aswad, Didier

    2016-01-01

    After more than 30 years of research, numerous studies have shown that injection drug use is associated with a wide range of adverse health outcomes such as drug overdoses, drug-related suicidal behaviours, comorbid psychiatric disorders, bloodborne pathogens and other infectious diseases, and traumas. This review explores new trends and prominent issues associated with injection drug use. The dynamic nature of injection drug use is underlined by examining its recent trends and changing patterns in Canada and other “high-income countries.” Three research topics that could further contribute to the development of comprehensive prevention and intervention strategies aimed at people who inject drugs are also discussed: risk behaviours associated with the injection of prescription opioids, binge injection drug use, and mental health problems as determinants of injection risk behaviours. PMID:27254088

  2. Clinical Experience With Acupoint Injection Combined With Packet Treatment of Hand Eczema%手部湿疹采用穴位注射联合封包治疗的临床体会

    Institute of Scientific and Technical Information of China (English)

    贾红玲

    2015-01-01

    目的:研究采用穴位注射联合封包治疗手部湿疹的疗效。方法选取我院收治的98例手部湿疹患者,随机分为对照组与观察组各49例。对照组单纯使用封包进行治疗,观察组在此基础上增加穴位注射进行联合治疗。结果观察组治疗后EASI分数下降情况明显高于对照组;观察组治疗总有效率明显高于对照组。结论运用穴位注射联合封包治疗手部湿疹的效果非常显著。%Objective To explore the effect of acupoint injection combined with packet treatment of hand eczema.Methods We selected 98 cases of hand eczema patients in our hospital, randomly divided into control group and observation group (49 cases in each group). The control group were treated using packet treatment, and the observation group were treated using acupoint injection combined with packet treatment.Results After treatment, the EASI scores of observation group decreased signiifcantly than those of the control group, the observation group total effective rate was signiifcantly higher than that in control group.Conclusion Hand eczema treated by acupoint injection and wrap therapy is very signiifcant.

  3. Experience on lumbar cistern tube drainage and intrathecal injection in the treatment of intracranial infection%腰大池置管引流加鞘内注射治疗颅内感染的体会

    Institute of Scientific and Technical Information of China (English)

    阿扎提; 郑鹏; 刘德全

    2014-01-01

    目的:探讨腰大池置管持续引流结合鞘内注射治疗颅脑外伤及开颅术后所致颅内感染的效果。方法:2009年5月-2014年5月颅脑外伤及开颅手术后颅内感染患者7例,应用腰大池置管持续外引流结合鞘内注射治疗。观察其疗效。结果:引流7~12 d,临床治愈6例,1例并发全脑室炎死亡。结论:颅脑外伤及开颅术后出现颅内感染的患者在全身应用敏感抗生素的前提下可采用腰大池置管持续外引流结合鞘内注射,该方法简便、安全、疗效肯定。%Objective:To investigate the therapeutic effect of lumbar cistern tube drainage and intrathecal injection in the treatment of intracranial infection caused by craniocerebral trauma and craniotomy.Methods:7 cases of intracranial infection caused by craniocerebral trauma and craniotomy were selected from May 2009 to May 2014.They were treated with lumbar cistern tube drainage and intrathecal injection.Observe the effect.Results:They were drainaged for 7~12 days.6 cases were cured.1 case complicated with full ventriculitis death.Conclusion:Patients with intracranial infection caused by craniocerebral trauma and craniotomy can be given lumbar cistern tube drainage and intrathecal injection under the premise of systemic application of sensitive antibiotic.This method is simple,safety and efficacy.

  4. Clinical experience of Xuebijing injection in treatment of acute pancreatitis 36 cases%血必净治疗急性胰腺炎36例临床研究

    Institute of Scientific and Technical Information of China (English)

    马超

    2011-01-01

    目的 探讨血必净注射液对急性胰腺炎患者的治疗效果.方法 将82例急性胰腺炎患者随机分为血必净治疗组和常规治疗组,常规治疗组接受改善胰周循环、抑酸、抑酶、抗炎治疗,血必净组在上述常规治疗基础上+血必净注射液40ml静点,1次/d.监测两组患者体征缓解时间、血尿淀粉酶变化情况.结果 两组体征缓解时间上无明显差异(P>0.05),血、尿淀粉酶变化有统计学意义(P>0.05).结论 血必净注射液能有效减轻急性胰腺炎症状,保护脏器功能.%Objective To discuss the treatment effect of Xuebijing injection on patients with acute pancreatits. Methods Totally 36 caces of patients with acute pancreatits were divided into two groups: Xuebijing treatment group and routine treatment group. Routine group was given improving pancreatic circulation, acid - suppressing, inhibiting enzymes, anti - inflammatory treatment. On the basis of this, Xuebijing treatment group was added Xuebijing injection 40ml once per day. Monitor the signs relief time and the change of amylase in blood and urine of the two groups. Results The signs relief time has no significant difference between two groups ( P >0. 05) ,the change of amylase in blood and urine has statistically significance ( P > 0. 05). Conclusions Xuebijing injection can effectively mitigate the signs of acute pancreatits, protect organ functions.

  5. 10 Cases of Nursing Experience of Dexamethasone Injection Treatment of Venous Catheterization Skin Allergy%地塞米松注射液治疗静脉置管皮肤过敏10例护理体会

    Institute of Scientific and Technical Information of China (English)

    高凌云

    2014-01-01

    Objective:To explore the deep venous catheter in PICC or al ergic reaction to the skin care ef ect of dexamethasone injection. Methods: from 2012 October to 2013 September in our hospital in 10 cases of local skin al ergy patients using dexamethasone injection coated and strengthen. The papula, blister patients: general y do not use alcohol wipe can be used for the first time, saline local sebum clean, with 0.5% iodophor disinfectant to be dried, coated with dexamethasone injection, to avoid the at ention of bubble film, IV3000 film can be pruned, increase the bandage times, general 2-3 day. Results: the use of dexamethasone, patients with a local al ergic skin, obviously relieve among papules, erythema, cure. No cases of lead to extubation due to local skin al ergic reaction. Conclusion: Dexamethasone Injection in the treatment of catheter after the skin has a good curative ef ect, is worth the clinical promotion.%目的:探讨地塞米松注射液在PICC或深静脉置管局部皮肤过敏护理效果。方法选取2012年10月~2013年9月我院对10例置管局部皮肤过敏患者使用地塞米松注射液外涂并加强换药。对丘疹、水疱患者:一般不使用酒精首次擦拭,可选用生理盐水进行局部皮脂清洁,再用0.5%碘伏常规消毒待干,外涂地塞米松注射液,贴膜时注意避开水泡,可修剪IV3000贴膜,增加换药次数,一般1次/2~3d。结果使用地塞米松后,患者局部过敏皮肤风疹团、丘疹明显缓解,红斑消退,达到治愈。无1例因局部皮肤过敏反应导致拔管。结论地塞米松注射液治疗置管后皮肤过敏有较好的疗效,值得临床推广。

  6. Clinical Experience of Acanthopanax Senticosus Injection in the Treatment of 60 Cases of Insomnia%刺五加注射液治疗失眠症60例临床体会

    Institute of Scientific and Technical Information of China (English)

    蒋琴; 祝红

    2011-01-01

    Objective To observe the clinical efficacy of Acanthopanax senticosus injection in the treatment of insomnia. Methods 60 insomnia cases were randomly divided into two groups: treatment group and control group (30 cases in each' group) . Patients in the treatment group were given A. Senticosus injection while thoese in the control group were given Glu injection. The curative effect, score of Pittsburgh Sleep Quality Index (PSQI) , Athens sleep quality score and adverse reactions were compared between the two groups. Results The total effective rate of treatment group was 76.67% and that of control group was 30% , there was significant difference between the two groups (P<0.05). There were significant improvement in the PSQI scores in both groups (P<0.05) and there was a significant difference between the two groups (P<0.05). No serious adverse reactions were found in both groups. Conclusion A. Senticosus injection is effective in the treatment of insomnia.%目的 观察刺五加注射液治疗失眠症的临床疗效.方法 将60例失眠患者随机分为治疗组和对照组各30例,治疗组采用刺五加注射液治疗,对照组采用5%葡萄糖注射液治疗,比较两组临床疗效、匹兹堡睡眠质量指数评分、Athens睡眠量表评分和不良反应.结果 治疗组总有效率为76.67%,对照组为30%,两组比较差异有统计学意义(P<0.05);两组匹兹堡睡眠质量指数评分治疗后较治疗前明显降低(P<0.05),两组间比较差异有统计学意义(P<0.05).两组均未见严重不良反应发生.结论 刺五加注射液治疗失眠症疗效确切.

  7. UPTF-TRAM experiments for SBLOCA: Evaluation of condensation processes in TRAM tests A6 and A7

    Energy Technology Data Exchange (ETDEWEB)

    Sonneburg, H.G.; Tuunanen, J.; Palazov, V.V. [Gesellschaft fuer Anlagen-und Reaktorsicherheit (GRS), Muenchen (Germany)

    1995-09-01

    The investigation of thermal-hydraulic phenomena related to reactor transients with accident management measures is the goal of the TRansient and accident Management (TRAM) experimental programme being carried out at the Upper Plenum Test Facility (UPTF) at Mannheim (Germany). These experimental investigations and test analyses are funded by the German Federal Minister for Research and Technology (BMFT). The UPTF simulates these phenomena in a 1:1 such relative to the dimension of a PWR. Condensation of steam during Emergency Core Cooling (ECC) water injection from accumulators into the primary system is one of the phenomena studied within the accumulators into the primary system is one of the phenomena studied within the TRAM programme. This phenomenon partly controls the efficiency of accumulator injection if the high pressure safety systems fail. Beside this, the condensation within the nitrogen inside the accumulator for a certain period controls the pressure development inside the accumulator. Thus, both condensation phenomena determine the ECC flow rate delivered to the primary system. Concerning the condensation inside the primary system, this is also of safety relevance in the case of Pressurized Thermal Shock (PTS) during cold leg injection.

  8. Ozone profiles obtained by DIAL technique at Maïdo Observatory in La Reunion Island: comparisons with ECC ozone-sondes, ground-based FTIR spectrometer and microwave radiometer measurements

    Directory of Open Access Journals (Sweden)

    Portafaix T.

    2016-01-01

    Full Text Available A DIAL lidar system performing stratospheric ozone profile measurements from 15 to 45 km is installed at Reunion Island (southwest of Indian Ocean. The purpose of this communication is to present this DIAL system mounted now at the new Maïdo Observatory since February 2013, and the ozone profile retrieval. The first stratospheric ozone profiles obtained during 2013 and 2014 will be presented and discussed. Inter-comparison and differences observed with other high vertical resolution ozone profiles performed by ECC ozonesonde will be shown. Finally, comparisons with low vertical resolution ozone profiles retrieved from microwave and FTIR remote sensing measurements performed at Maïdo will be carried out, making appropriate use of the associated averaging kernels

  9. Ozone profiles obtained by DIAL technique at Maïdo Observatory in La Reunion Island: comparisons with ECC ozone-sondes, ground-based FTIR spectrometer and microwave radiometer measurements

    Science.gov (United States)

    Portafaix, T.; Godin-Beekmann, S.; Payen, G.; de Mazière, M.; Langerock, B.; Fernandez, S.; Posny, F.; Cammas, J. P.; Metzger, J. M.; Bencherif, H.; Vigouroux, C.; Marquestaut, N.

    2016-06-01

    A DIAL lidar system performing stratospheric ozone profile measurements from 15 to 45 km is installed at Reunion Island (southwest of Indian Ocean). The purpose of this communication is to present this DIAL system mounted now at the new Maïdo Observatory since February 2013, and the ozone profile retrieval. The first stratospheric ozone profiles obtained during 2013 and 2014 will be presented and discussed. Inter-comparison and differences observed with other high vertical resolution ozone profiles performed by ECC ozonesonde will be shown. Finally, comparisons with low vertical resolution ozone profiles retrieved from microwave and FTIR remote sensing measurements performed at Maïdo will be carried out, making appropriate use of the associated averaging kernels

  10. Young people at risk of transitioning to injecting drug use in Sydney, Australia: social disadvantage and other correlates of higher levels of exposure to injecting.

    Science.gov (United States)

    Lea, Toby; Bryant, Joanne; Ellard, Jeanne; Howard, John; Treloar, Carla

    2015-03-01

    While numerous studies have examined characteristics of young people who have recently initiated injecting, little attention has focused on young people who may be at high risk of transitioning to injecting. This study sought to examine the extent that socially disadvantaged young people were exposed to injecting, determine their level of hepatitis C (HCV) knowledge and identify correlates of higher injecting exposure. A cross-sectional survey was administered to 210 young people in 2010-2011 who were exposed to injecting drug use, but had not transitioned to injecting. Respondents were primarily recruited from youth services in metropolitan Sydney. Exposure to injecting in the previous 12 months was assessed with four items that examined whether close friends, romantic/sexual partners or family members/acquaintances injected drugs, and whether they were offered an injection. Most respondents had at least a few close friends who injected drugs (65%) and almost half had been offered drugs to inject in the previous 12 months (48%). It was less common for respondents to report having a partner who injects (11%). Correlates of higher injecting exposure were examined with multivariate ordinal regression. In the multivariate model, higher exposure to injecting was independently associated with the experience of abuse or violent crime [adjusted odds ratio (AOR) = 1.80] and reporting more favourable attitudes towards injecting (AOR = 0.86). Higher exposure to injecting was not independently associated with patterns or history of drug use. HCV knowledge was low to moderate and was not associated with higher exposure to injecting. That drug use was not independently associated with higher injecting exposure may suggest that exposure is shaped more by social disadvantage than by drug use patterns. Additional research is required to investigate this, using an improved measure of exposure to injecting. © 2014 John Wiley & Sons Ltd.

  11. Full Life Cycle Research at the Ketzin Pilot Site, Germany - From Safe and Successful CO2 Injection Operation to Post-Injection Monitoring and Site Closure

    Science.gov (United States)

    Liebscher, A. H.

    2016-12-01

    The Ketzin pilot site near Berlin, Germany, was initiated in 2004 as the first European onshore storage project for research and development on geological CO2 storage. The operational CO2 injection period started in June 2008 and ended in August 2013 when the site entered the post-injection closure period. During these five years, a total amount of 67 kt of CO2 was safely injected into a saline aquifer (Upper Triassic sandstone) at a depth of 630 m - 650 m. In fall 2013, the first observation well was partially plugged in the reservoir section; full abandonment of this well finished in 2015 after roughly 2 years of well closure monitoring. Abandonment of the remaining 4 wells will be finished by 2017 and hand-over of liability to the competent authority is planned for end of 2017. The CO2 injected was mainly of food grade quality (purity > 99.9%). In addition, 1.5 kt of CO2 from the pilot capture facility "Schwarze Pumpe" (oxyfuel power plant CO2 with purity > 99.7%) was injected in 2011. The injection period terminated with a CO2-N2 co-injection experiment of 650 t of a 95% CO2/5% N2 mixture in summer 2013 to study the effects of impurities in the CO2 stream on the injection operation. During regular operation, the CO2 was pre-heated on-site to 40 - 45°C prior to injection to ensure a single-phase injection process and avoid any phase transition or transient states within the injection facility or the reservoir. Between March and July 2013, just prior to the CO2-N2 co-injection experiment, the injection temperature was stepwise decreased down to 10°C within a "cold-injection" experiment to study the effects of two-phase injection conditions. During injection operation, the combination of different geochemical and geophysical monitoring methods enabled detection and mapping of the spatial and temporal in-reservoir behaviour of the injected CO2 even for small quantities. After the cessation of CO2 injection, post-injection monitoring continued and two additional

  12. Evaluation of the impact of viscosity, injection volume, and injection flow rate on subcutaneous injection tolerance.

    Science.gov (United States)

    Berteau, Cecile; Filipe-Santos, Orchidée; Wang, Tao; Rojas, Humberto E; Granger, Corinne; Schwarzenbach, Florence

    2015-01-01

    The primary objective of this study was to evaluate the impact of fluid injection viscosity in combination with different injection volumes and flow rates on subcutaneous (SC) injection pain tolerance. The study was a single-center, comparative, randomized, crossover, Phase I study in 24 healthy adults. Each participant received six injections in the abdomen area of either a 2 or 3 mL placebo solution, with three different fluid viscosities (1, 8-10, and 15-20 cP) combined with two different injection flow rates (0.02 and 0.3 mL/s). All injections were performed with 50 mL syringes and 27G, 6 mm needles. Perceived injection pain was assessed using a 100 mm visual analog scale (VAS) (0 mm/no pain, 100 mm/extreme pain). The location and depth of the injected fluid was assessed through 2D ultrasound echography images. Viscosity levels had significant impact on perceived injection pain (P=0.0003). Specifically, less pain was associated with high viscosity (VAS =12.6 mm) than medium (VAS =16.6 mm) or low (VAS =22.1 mm) viscosities, with a significant difference between high and low viscosities (P=0.0002). Target injection volume of 2 or 3 mL was demonstrated to have no significant impact on perceived injection pain (P=0.89). Slow (0.02 mL/s) or fast (0.30 mL/s) injection rates also showed no significant impact on perceived pain during SC injection (P=0.79). In 92% of injections, the injected fluid was located exclusively in SC tissue whereas the remaining injected fluids were found located in SC and/or intradermal layers. The results of this study suggest that solutions of up to 3 mL and up to 15-20 cP injected into the abdomen within 10 seconds are well tolerated without pain. High viscosity injections were shown to be the most tolerated, whereas injection volume and flow rates did not impact perceived pain.

  13. Longitudinal Trajectories of Ketamine Use among Young Injection Drug Users

    Science.gov (United States)

    Lankenau, Stephen E.; Bloom, Jennifer Jackson; Shin, Charles

    2010-01-01

    Background Ketamine is a dissociative anesthetic that became increasing popular in the club and rave scene in the 1980s and 1990s. Reports surfaced in the late 1990s indicating that ketamine was being injected in several U.S. cities by young injection drug users (IDUs). Since all studies on ketamine injection were cross-sectional, a longitudinal study was undertaken in 2005 to determine: characteristics of young IDUs who continue to inject ketamine; frequency of ketamine injection over an extended time period; risks associated with ongoing ketamine injection; and environmental factors that impact patterns of ketamine use. Methods Young IDUs aged 16 to 29 with a history of injecting ketamine (n=101) were recruited from public locations in Los Angeles and followed during a two-year longitudinal study. A semi-structured instrument captured quantitative and qualitative data on patterns of ketamine injection and other drug use. A statistical model sorted IDUs who completed three or more interviews (n=66) into three groups based upon patterns of ketamine injection at baseline and follow-up. Qualitative analysis focused on detailed case studies within each group. Results IDUs recruited at baseline were typically in their early 20s, male, heterosexual, white, and homeless. Longitudinal injection trajectories included: “Moderates,” who injected ketamine several times per year (n=5); “Occasionals,” who injected ketamine approximately once per year (n=21); and “Abstainers,” who did not inject any ketamine during follow-up (n=40). Findings suggest that ketamine is infrequently injected compared to other drugs such as heroin, cocaine, and methamphetamine. Most IDUs who begin injecting ketamine will stop or curb use due to: negative or ambivalent experiences associated with ketamine; an inability to find the drug due to declining supply; or maturing out of injecting drugs more generally. Conclusion Reducing ketamine injection among young IDUs may best be accomplished

  14. Effects of injection pressure and injection timing to exhaust gas opacity for a conventional indirect diesel engine

    Science.gov (United States)

    Budiman, Agus; Majid, Akmal Irfan; Pambayun, Nirmala Adhi Yoga; Yuswono, Lilik Chaerul; Sukoco

    2016-06-01

    In relation to pollution control and environmental friendliness, the quality of exhaust gas from diesel engine needs to be considered. The influences of injection pressure and timing to exhaust gas opacity were investigated. A series of experiments were conducted in a one-cylinder conventional diesel engine with a naturally aspirated system and indirect injection. The default specification of injection pressure was 120 kg/cm2. To investigate the injection pressure, the engine speed was retained on 1000 rpm with pressure variations from 80 to 215 kg/cm2. On the other hand, the various injection timing (8, 10, 12, 16 degrees before TDC point and exact 18 degrees before TDC point) were used to determine their effects to exhaust gas opacity. In this case, the engine speed was varied from 1000 to 2400 rpm. The injector tester was used to measure injection pressure whereas the exhaust gas opacity was determined by the smoke meter. Those data were also statistically analyzed by product moment correlation. As the results, the injection pressure of diesel engine had a non-significant positive correlation to the exhaust gas opacity with r = 0.113 and p > 5 %. Injection pressure should be adjusted to the specification listed on the diesel engine as if it was too high or too low will lead to the higher opacity. Moreover, there was a significant positive correlation between injection timing and the exhaust gas opacity in all engine speeds.

  15. Research on the test method of using injection as an equivalent substitute for electromagnetic radiation

    Science.gov (United States)

    Pan, X. D.; Wei, G. H.; Lu, X. F.; Li, K.

    2013-03-01

    This paper presents a method to carry out high intensity radiated field (HIRF) effect experiments by using injection as an equivalent substitute for electromagnetic radiation. In allusion to typical interconnected system, the equal response voltage on the equipment cable port is regarded as an equivalent basis of injection and radiation methods. The equivalent relation formula between injected voltage and radiated field is derived theoretically. The conditions needed for extrapolating injected voltage in HIRF are confirmed, and the extrapolation method is proposed. On the basis of the above research, the electromagnetic environment effect test new method combined injection with radiation for interconnected system is summarized. The typical nonlinear interconnected system is selected as equipment under test, and the single frequency continuous wave radiation and injection effect experiments are carried out separately. The test results indicate that the relation between radiated field and injected voltage is linear, and the equivalent injected voltage used to substitute HIRF can be obtained by linear extrapolation.

  16. SQL Injection Attacks and Defense

    CERN Document Server

    Clarke, Justin

    2012-01-01

    SQL Injection Attacks and Defense, First Edition: Winner of the Best Book Bejtlich Read Award "SQL injection is probably the number one problem for any server-side application, and this book unequaled in its coverage." -Richard Bejtlich, Tao Security blog SQL injection represents one of the most dangerous and well-known, yet misunderstood, security vulnerabilities on the Internet, largely because there is no central repository of information available for penetration testers, IT security consultants and practitioners, and web/software developers to turn to for help. SQL Injection Att

  17. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes.

  18. Supersonic Jet Noise Reduction Using Flapping Injection and Pulsed Injection

    Science.gov (United States)

    Hafsteinsson, Haukur; Eriksson, Lars-Erik; Cuppoletti, Daniel; Gutmark, Ephraim; Department of Applied Mechanics, Chalmers University of Technology Team; Department of Aerospace Engineering, University of Cincinatti Team; Swedish Defence Material Administration, Sweden Team

    2013-11-01

    Aircraft are in general noisy and there is a high demand for reducing their noise levels. The jet exhaust is in most cases the main noise source of the aircraft, especially for low bypass ratio jet engines. Fluidic injection affecting the shear layer close to the nozzle exit is a promising noise reduction technique as it can be turned of while not needed and thus the negative effect on the engine performance will be minimized. In the presented work, LES is used to compare steady-state mass flow injection with steady-state mass flow flapping jet injection. The work is a direct continuation of a previous LES study on pulsed injection which showed that the pulsed injection induced pressure pulses in the jet which caused increased tonal noise in the downstream directions. The injection system considered in the presented work consists of eight evenly distributed injectors at the nozzle exit plane with a 90° injection angle relative to the flow direction. Flapping jet injection is believed to minimize the creation of these pressure pulses since it provides steady-state mass flow. This work is funded by Swedish Defense Material Administration (FMV).

  19. Theory and application of the transient injection well test

    Institute of Scientific and Technical Information of China (English)

    LIU Yuewu; CHEN Huixin; LIU Qingquan; GONG Xin; ZHANG Dawei; YAO Deliang; LI Lianxiang

    2005-01-01

    Based on the theory of the pumping well test, the transient injection well test was suggested in this paper. The design method and the scope of application are discussed in detail. The mathematical models are developed for the short-time and long-time transient injection test respectively. A double logarithm type curve matching method was introduced for analyzing the field transient injection test data. A set of methods for the transient injection test design, experiment performance and data analysis were established. Some field tests were analyzed, and the results show that the test model and method are suitable for the transient injection test and can be used to deal with the real engineering problems.

  20. Process Condition Monitoring of Micro Moulding Using a Two-plunger Micro Injection Moulding Machine

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Guerrier, Patrick

    2010-01-01

    The influence of micro injection moulding (µIM) process parameters (melt and mould temperature, piston injection speed and stoke length) on the injection pressure was investigated using Design of Experiments. Direct piston injection pressure measurements were performed and data collected using a ...... diferent processing conditions were evaluated to correlate the process parameter levels influence on the selected responses, considering both average values (for processes characterization) and standard derivations (for process robustness assessment)....

  1. The effect of blood injection for the prevention of Ethanol reflux after intrahepatic Ethanol injection in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Kook Jin; Kim, Choon Yul; Kim, Bum Soo; Hahn, Seong Tai; Lee, Jae Mun; Shinn, Kyung Sub [Catholic Univ., College of Medicine, Seoul (Korea, Republic of)

    1998-09-01

    To reduce ethanol reflux from the needle channel by injecting rat blood immediately after the injection of ethanol into rat liver. The first experiment involved 33 rat livers which were divided into four groups (three livers in group 1;ten in groups 2, 3, and 4). Group 1 animals were used as controls, and 0.1ml saline was injected into the liver; in group 2, ethanol-Tc-99m-O{sub 4}- mixed solution (0.1ml, 0.2mCi) was injected into the liver;in groups 3 and 4, the needle channel was blocked with 0.02ml of fresh blood and old blood, respectively, after the injection of ethanol. After removing the needle, a 3cm round filter paper was laid on each injection site to absorb refluxed ethanol-T{sub c}-99m-O{sub 4}- mixed solution from the liver, and each paper was then counted by a gamma camera unit. In the second experiment, 33rats were divided into four groups (three rats in group 1;ten in groups 2, 3, and 4). Group 1 animals were used as controls, and after exposing the left lateral lobe of the liver, 0.05 ml of saline was injected;in group 2, 0.05 ml of ethanol was injected into the livder;in groups 3 and 4 the needle channel was blocked with 0.02 ml of fresh blood and old blood, respectively, after the injection of ethanol. After ten days, peritoneal adhesions were scored macroscopically and microscopically. In the first experiment using ethanol- T{sub c}-99m-O{sub 4}- mixed solution, groups blocked with blood after the injection of mixed solution showed lower gamma counts than the group injected with mixed solution only (p-value=3D0.0002). The group blocked with old blood showed the lowest count. Macroscopical and microscopical examination of peritoneal adhesions indicated that the grade of adhesion was lower in groups blocked with blood than in the group injected with ethanol onluy (p-value=3D0.0261 and 0.0163, respectively). The above results suggest that an injection of blood after an injection of ethanol is a very effective way of preventing reflux from the liver

  2. Rapid injection of rocuronium reduces withdrawal movement on injection.

    Science.gov (United States)

    Lee, Yong Cheol; Jang, Young Ho; Kim, Jin Mo; Lee, Sang Gyu

    2009-09-01

    To test whether rapid injection of rocuronium reduces withdrawal movement on injection. Randomized, prospective trial. Operating room in a university hospital. 150 ASA physical status I and II patients aged 18 to 60 years, undergoing general anesthesia. Patients were randomized to three groups. After undergoing anesthesia induction with thiopental sodium, then 5 seconds later receiving a rubber tourniquet applied to the mid-forearm to stop intravenous (IV) flow by gravity, the pretreatment drug was injected. The tourniquet was held for 15 seconds then released, and 1.0 mg/kg of 1% rocuronium was injected IV. Group C patients (n = 50) were pretreated with 0.1 mL/kg of 0.9% NaCl and then injected with rocuronium slowly within 10 seconds. Group L patients (n = 50) were pretreated with 0.1 mL/kg of preservative-free 1% lidocaine and then injected with rocuronium slowly within 10 seconds. Group R patients (n = 50) were pretreated with 0.1 mL/kg of 0.9% NaCl and then rapidly injected with rocuronium within approximately one second (as quickly as possible). After injection of the patient with the study drug, a single anesthesiologist with no knowledge of the study protocol graded each patient's response as follows: 0 = no response; 1 = mild movement limited to the wrist only; 2 = moderate movement involving the elbow and shoulder; and 3 = severe movement involving more than one extremity. Group C had the most intense and frequent withdrawal response. The frequency and intensity of withdrawal movement was significantly less in Groups L and R than Group C. No significant difference in withdrawal response between Groups L and R was noted. Withdrawal response can be significantly reduced for rocuronium injection without lidocaine pretreatment, simply through rapid injection.

  3. MR epidurography: distribution of injectate at caudal epidural injection

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Darra T. [Cappagh National Orthopedic Hospital, Dublin 11 (Ireland); St Paul' s Hospital, Department of Radiology, Vancouver, BC (Canada); Kavanagh, Eoin C.; Moynagh, Michael R.; Eustace, Stephen [Cappagh National Orthopedic Hospital, Dublin 11 (Ireland); Mater Misericordiae University Hospital, Dublin 7 (Ireland); Poynton, Ashley; Chan, Vikki O. [Cappagh National Orthopedic Hospital, Dublin 11 (Ireland)

    2014-08-02

    To (a) evaluate the feasibility of MR epidurography (MRE) and (b) assess the distribution of injectate using two different volumes at caudal epidural steroid injection. Twenty patients who were referred with symptomatic low back pain for caudal epidural steroid injection were assigned to have either 10 ml (9/20) or 20 ml (11/20) of injectate administered. Gadolinium was included in the injection. The patients proceeded to MRI where sagittal and coronal T1-weighted fat-saturated sequences were acquired and reviewed in the mid-sagittal and right and left parasagittal views at the level of the exit foramina. Gadolinium was observed at or above the L3/4 disc level in all 11 patients who received 20 ml (100 %), compared with only five of nine patients who received 10 ml (56 %). Injectate was seen to the L4 nerve root level in all 11 patients who received 20 ml (100 %) but only four out of nine patients who received 10 ml (44 %), not even reaching the L5 nerve root level in four further of these nine patients (44 %). Overall, there was a trend to visualize gadolinium at higher levels of the epidural space with higher volumes injected. Firstly, MR epidurography is a safe technique that allows excellent visualization of the distribution of gadolinium in the epidural space following injection via the caudal hiatus. Secondly, a volume of 10 ml is unlikely to treat L5/S1 disease in almost half of patients at caudal epidural steroid injection and at least 20 ml of injectate is likely required for any medication to reach the desired level. (orig.)

  4. Prime injections and quasipolarities

    Directory of Open Access Journals (Sweden)

    Octavio Alberto Agustín-Aquino

    2014-05-01

    Full Text Available Let $p$ be a prime number. Consider the injection\\[ \\iota:\\mathbb{Z}/n\\mathbb{Z}\\to\\mathbb{Z}/pn\\mathbb{Z}:x\\mapsto px, \\]and the elements $e^{u}.v:=(u,v\\in \\mathbb{Z}/n\\mathbb{Z}\\rtimes \\mathbb{Z}/n\\mathbb{Z}^{\\times}$ and$e^{w}.r:=(w,r\\in \\mathbb{Z}/pn \\mathbb{Z}\\rtimes \\mathbb{Z}/pn\\mathbb{Z}^{\\times}$. Suppose that $e^{u}.v\\in\\mathbb{Z}/n\\mathbb{Z}\\rtimes \\mathbb{Z}/n\\mathbb{Z}^{\\times}$ is seen as an automorphism of $\\mathbb{Z}/n\\mathbb{Z}$defined by $e^{u}.v(x=vx+u$; then $e^{u}.v$ is a \\emph{quasipolarity} if it is an involution without fixed points.In this brief note we give an explicit formula for the number of quasipolarities of $\\mathbb{Z}/n\\mathbb{Z}$ interms of the prime decomposition of $n$, and we prove sufficient conditions such that $(e^{w}.r\\circ \\iota=\\iota\\circ (e^{u}.v$, where $e^{w}.r$ and $e^{u}.v$ are quasipolarities.

  5. Prediction of Gas Injection Performance for Heterogeneous Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Blunt, Martin J.; Orr, Jr., Franklin M.

    1999-12-20

    This report describes research carried out in the Department of Petroleum Engineering at Stanford University from September 1998 - September 1998 under the third year of a three-year Department of Energy (DOE) grant on the ''Prediction of Gas Injection Performance for Heterogeneous Reservoirs''. The research effort is an integrated study of the factors affecting gas injection, from the pore scale to the field scale, and involves theoretical analysis, laboratory experiments and numerical simulation. The research is divided into four main areas: (1) Pore scale modeling of three-phase flow in porous media; (2) Laboratory experiments and analysis of factors influencing gas injection performance at the core scale with an emphasis on the fundamentals of three-phase flow; (3) Benchmark simulations of gas injection at the field scale; and (4) Development of streamline-based reservoir simulator.

  6. Injection treatments for patellar tendinopathy

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; van den Akker-Scheek, Inge

    2011-01-01

    Objective Injection treatments are increasingly used as treatment for patellar tendinopathy. The aim of this systematic review is to describe the different injection treatments, their rationales and the effectiveness of treating patellar tendinopathy. Methods A computerised search of the Medline, Em

  7. Interferon Alfa-2b Injection

    Science.gov (United States)

    Interferon alfa-2b injection is used to treat a number of conditions.Interferon alfa-2b injection is used alone or in ... Hodgkin's lymphoma (NHL; a slow-growing blood cancer). Interferon alfa-2b is in a class of medications ...

  8. Towards spin injection into silicon

    Energy Technology Data Exchange (ETDEWEB)

    Dash, S.P.

    2007-08-15

    Si has been studied for the purpose of spin injection extensively in this thesis. Three different concepts for spin injection into Si have been addressed: (1) spin injection through a ferromagnet-Si Schottky contact, (2) spin injection using MgO tunnel barriers in between the ferromagnet and Si, and (3) spin injection from Mn-doped Si (DMS) as spin aligner. (1) FM-Si Schottky contact for spin injection: To be able to improve the interface qualities one needs to understand the atomic processes involved in the formation of silicide phases. In order to obtain more detailed insight into the formation of such phases the initial stages of growth of Co and Fe were studied in situ by HRBS with monolayer depth resolution.(2) MgO tunnel barrier for spin injection into Si: The fabrication and characterization of ultra-thin crystalline MgO tunnel barriers on Si (100) was presented. (3) Mn doped Si for spin injection: Si-based diluted magnetic semiconductor samples were prepared by doping Si with Mn by two different methods i) by Mn ion implantation and ii) by in-diffusion of Mn atoms (solid state growth). (orig.)

  9. Injection treatments for patellar tendinopathy

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; van den Akker-Scheek, Inge

    2011-01-01

    Objective Injection treatments are increasingly used as treatment for patellar tendinopathy. The aim of this systematic review is to describe the different injection treatments, their rationales and the effectiveness of treating patellar tendinopathy. Methods A computerised search of the Medline, Em

  10. An experimental investigation on hydrogen fuel injection in intake port and manifold with different EGR rates

    Directory of Open Access Journals (Sweden)

    N.Saravanan, G.Nagarajan

    2010-03-01

    Full Text Available In the present investigation hydrogen was used in a diesel engine in the dual fuel mode using diesel as an ignition source. In order to have a precise control of hydrogen flow and to avoid the backfire and pre-ignition problems hydrogen was injected into the intake system. Experiments were conducted to determine the optimized injection timing, injection duration and injection quantity of the fuel in manifold and port injected hydrogen-operated engine using diesel as ignition source for hydrogen operation. From the results it was observed that in manifold injection technique the optimized condition was start of injection at gas exchange top dead centre (GTDC with injection duration of 30o crank angle (CA with hydrogen flow rate of 7.5 litres/min. In port injection technique, the optimized condition was start of injection at 5o before gas exchange top dead centre (5o BGTDC with injection duration of 30o CA with hydrogen flow rate of 7.5 litres/min. With the above optimized timings of port and manifold injection it was observed that brake thermal efficiency in port injection increases by 13 % and 16 % in manifold injection at 75 % load. However at full load the brake thermal efficiency decreases by 1 % in port injection and 8 % in manifold injection. A reduction in NOX emission by 4 times is observed in port injection and 7 times in manifold injection at full load. At 75 % load the NOX emission reduces by 3 times in both port injection and manifold injection. Smoke emission increases with increase in EGR percentage. The smoke increases by 36 % at full load in port injection and by 44 % in manifold injection. At 75 % load the smoke emission reduces by 13 % in port injection and 9 % in manifold injection. In both the port injection and manifold injection ignition delay was 12o or 1.33 ms while for diesel it was 11o or 1.22 ms. Port injection system with diesel as ignition source operates smoothly and shows improved performance and emit lesser

  11. Zinc injection in German PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Stellwag, B. [Framatome ANP GmbH, Erlangen (Germany); Juergensen, M. [Kernkraftwerk Obrigheim GmbH (Germany); Wolter, D. [RWE Power AG, Kraftwerk Biblis (Germany)

    2002-07-01

    Zinc injection for further reduction of radiation fields was introduced at Unit B of Biblis Nuclear Power Station in September 1996 and at Obrigheim Nuclear Power Station in February 1998. Zinc injection is still being implemented today at these plants. This paper gives an overview of the experience acquired with the method, including the annual refueling outages in the year 2001. The main topic addressed by the paper is the evolution of dose rates at the primary system and work-related doses since introduction of the method. Reductions in high dose rate areas have meanwhile achieved values of 40 to 50%. Annual collective doses per man-hour spent in the controlled access area of the plant as well as personal doses for specific activities are also decreasing. (authors)

  12. Simulation of the injection moulding process

    Science.gov (United States)

    Hu, J.; Christensen, T.

    1993-12-01

    Simulation of the injection molding process is a helpful way for the engineers who work with plastics processing. By simulation, they will get some important parameters which sometimes are highly necessary for the mold design and processing. Thus, the engineers will save much time to do experiments for the parameters. Two simulation programs are used in this report, namely CADMOULD and CADMOULD MEFISTO which are designed by Institut fur Kunststoffverarbeitung (IKV) in Aachen, W. Germany. CADMOULD works with 2-D geometry and is specialized for rheological, thermal and mechanical calculation. It is installed on a personal computer, while CADMOULD MEFISTO works in 3-D and is installed on a VAX 8530 computer at SINTEF. A PC version of this program is also available. This report deals with CADMOULD and CADMOULD MEFISTO. The construction of flow lines, balancing of sprue system, the optimizing of injection time, and gate(s) optimizing are mainly included.

  13. Design and validation of a simulator for equine joint injections.

    Science.gov (United States)

    Fox, Victoria; Sinclair, Charlotte; Bolt, David M; Lowe, John; Weller, Renate

    2013-01-01

    Joint injections are commonly used in equine practice for diagnosis and treatment of joint disorders. Performing joint injections is hence an essential skill for equine practitioners. However, opportunities for veterinary students to practice this skill are often scarce in veterinary curricula. The aim of this study was to design and validate an equine joint injection simulator. We hypothesized that the simulator will enhance student ability and confidence in performing joint injections. The simulator was constructed around an equine forelimb skeleton with soft tissues rebuilt using building foam and rubber bands. An electrical circuit including a buzzer, a battery, wire wool in the joints, and a hypodermic needle at the end of the cable was incorporated. If the students placed the needle into the joint correctly, instant auditory feedback was provided by the buzzer. To validate the simulator, 45 veterinary students were allocated to three groups: cadaver limb, textbook, or simulator. Students' ability to perform joint injections was tested and students' opinions were evaluated with a questionnaire. The proportion of students performing a metacarpophalangeal (MCP) joint injection correctly was significantly higher in the cadaver (93%) and simulator (76%) groups compared to the textbook group (50%). There was no significant difference between groups for performing a distal interphalangeal (DIP) joint injection correctly. Students rated the learning experience with the cadaver and simulator group high and with the textbook group low. The joint injection simulator represents an affordable teaching aid that allows students to repeatedly practice this skill in their own time with immediate feedback.

  14. Giant tunnel-electron injection in nitrogen-doped graphene

    DEFF Research Database (Denmark)

    Lagoute, Jerome; Joucken, Frederic; Repain, Vincent

    2015-01-01

    Scanning tunneling microscopy experiments have been performed to measure the local electron injection in nitrogen-doped graphene on SiC(000) and were successfully compared to ab initio calculations. In graphene, a gaplike feature is measured around the Fermi level due to a phonon-mediated tunneling...... and at carbon sites. Nitrogen doping can therefore be proposed as a way to improve tunnel-electron injection in graphene....

  15. Technical tips for collagenase injection treatment for Dupuytren contracture.

    Science.gov (United States)

    Meals, Roy A; Hentz, Vincent R

    2014-06-01

    We describe technical tips for injecting collagenase into Dupuytren cords based on experience acquired during the prerelease Food and Drug Administration clinical trials and with subsequent clinical practice. These tips include techniques for extracting the reconstituted enzyme efficiently from the vial, injecting the cord(s) with increased safety to the tendons, and anesthetizing the hand before manipulation. The tips are intended to supplement but by no means replace the manufacturer's prescribing information and training video.

  16. Tracer injection techniques in flowing surface water

    Science.gov (United States)

    Wörman, A.

    2009-04-01

    Residence time distributions for flowing water and reactive matter are commonly used integrated properties of the transport process for determining technical issues of water resource management and in eco-hydrological science. Two general issues for tracer techniques are that the concentration-vs-time relation following a tracer injection (the breakthrough curve) gives unique transport information in different parts of the curve and separation of hydromechanical and reactive mechanisms often require simultaneous tracer injections. This presentation discusses evaluation methods for simultaneous tracer injections based on examples of tracer experiments in small rivers, streams and wetlands. Tritiated water is used as a practically inert substance to reflect the actual hydrodynamics, but other involved tracers are Cr(III)-51, P-32 and N-15. Hydromechanical, in-stream dispersion is reflected as a symmetrical spreading of the spatial concentration distribution. This requires that the transport distance over water depth is larger than about five times the flow Peclet number. Transversal retention of both inert and reactive solutes is reflected in terms of the tail of the breakthrough curve. Especially, reactive solutes can have a substantial magnification of the tailing behaviour depending on reaction rates or partitioning coefficients. To accurately discriminate between the effects of reactions and hydromechanical mixing its is relevant to use simultaneous injections of inert and reactive tracers with a sequential or integrated evaluation procedure. As an example, the slope of the P-32 tailing is consistently smaller than that of a simultaneous tritium injection in Ekeby wetland, Eskilstuna. The same applies to N-15 injected in the same experiment, but nitrogen is affected also by a systematic loss due to denitrification. Uptake in stream-bed sediments can be caused by a pumping effect arising when a variable pressure field is created on the stream bottom due to bed

  17. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  18. Sensor for Injection Rate Measurements

    Directory of Open Access Journals (Sweden)

    Milan Marcic

    2006-10-01

    Full Text Available A vast majority of the medium and high speed Diesel engines are equipped withmulti-hole injection nozzles nowadays. Inaccuracies in workmanship and changinghydraulic conditions in the nozzles result in differences in injection rates between individualinjection nozzle holes. The new deformational measuring method described in the paperallows injection rate measurement in each injection nozzle hole. The differences in injectionrates lead to uneven thermal loads of Diesel engine combustion chambers. All today knownmeasuring method, such as Bosch and Zeuch give accurate results of the injection rate indiesel single-hole nozzles. With multihole nozzles they tell us nothing about possibledifferences in injection rates between individual holes of the nozzle. At deformationalmeasuring method, the criterion of the injected fuel is expressed by the deformation ofmembrane occurring due to the collision of the pressure wave against the membrane. Thepressure wave is generated by the injection of the fuel into the measuring space. For eachhole of the nozzle the measuring device must have a measuring space of its own into whichfuel is injected as well as its measuring membrane and its own fuel outlet. Duringmeasurements procedure the measuring space must be filled with fuel to maintain anoverpressure of 5 kPa. Fuel escaping from the measuring device is conducted into thegraduated cylinders for measuring the volumetric flow through each hole of the nozzle.Themembrane deformation is assessed by strain gauges. They are glued to the membrane andforming the full Wheatstone’s bridge. We devoted special attention to the membrane shapeand temperature compensation of the strain gauges.

  19. LHC injection and dump protection

    CERN Document Server

    Bartmann, W; Bracco, C; Goddard, B; Kain, V; Rossi, A; Wollmann, D

    2010-01-01

    The machine protection against fast failures including injection or dump kickers relies on fixed and movable devices. Results will be shown from the low-intensity beam commissioning of the moveable injection protection devices in the SPS to LHC transfer lines and downstream of the LHC injection kickers, and of the LHC dump protection elements in IR6. This paper is almost exclusively focussing on the issues arising during the 2009 commissioning. The implications of these results and a commissioning status report with the planning for 2010 will be addressed.

  20. Financial methods for waterflooding injectate design

    Energy Technology Data Exchange (ETDEWEB)

    Heneman, Helmuth J.; Brady, Patrick V.

    2017-08-08

    A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.