WorldWideScience

Sample records for ecc injection experiments

  1. Experiments on injection performance of SMART ECC facility using SWAT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Min, Kyoung Ho; Shin, Yong Cheol; Kwon, Tae Soon; Yi, Sung Jae; Lee, Won Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    SMART (System-integrated Modular Advanced ReacTor), an advanced integrated PWR is now in the under developing stages by KAERI. Such integral PWR excludes large-size piping of the primary system of conventional PWR and incorporates the SGs into RPV, which means no LBLOCA could occur in SMART. Therefore, the SBLOCA is considered as a major DBA (Design Basis Accident) in SMART and it is mainly analyzed by using TASS/SMR computer code. The TASS/SMR code should be validated using experimental data from both Integral Effect Test and Separate Effect Test facilities. To investigate injection performance of the ECC system, on SET facility, named as SWAT (SMART ECC Water Asymmetric Two-phase choking test facility), has been constructed at KAERI. The SWAT simulates the geometric configurations of the SG-side upper downcomer annulus and ECCSs of those of SMART. It is designed based on the modified linear scaling method with a scaling ratio of 1/5, to preserve the geometrical similarity and minimize gravitational distortion. The purpose of the SWAT tests is to investigate the safety injection performance, such as the ECC bypass in the downcomer and the penetration rate in the core during the SBLOCA, and hence to produce experimental data to validate and the prediction capability of safety analysis codes, TASS/SMR

  2. Experiment data report for Semiscale Mod-1 Test S-05-3 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-03-01

    Recorded test data are presented for Test S-05-3 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-3 was conducted from initial conditions of 2263 psia and 545 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg sides of the intact and broken loops and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. For Test S-05-3, specifically the effects of upper plenum coolant injection on core thermal and system response were being investigated

  3. Experiment data report for Semiscale Mod-1 Test S-05-1 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-1 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-1 was conducted from initial conditions of 2263 psia and 544 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the vessel lower plenum to simulate emergency core coolant injection in a PWR, with the flow rate based on system volume scaling

  4. Experiment data report for Semiscale Mod-1 Test S-05-5 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Patton, M.L. Jr.; Sackett, K.E.

    1977-04-01

    Recorded test data are presented for Test S-05-5 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-5 was conducted from initial conditions of 2263 psia and 537 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. The upper plenum was vented through a reflood bypass line interconnecting the hot and cold legs of the broken loop

  5. Experiment data report for Semiscale Mod-1 Test S-05-2 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Collins, B.L.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-2 of the Semiscale Mod-1 alternate emergency core coolant (ECC) injection test series. This test is one of several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-2 was conducted from an initial cold leg fluid temperature of 545 0 F and an initial pressure of 2263 psia. A simulated double-ended offset shear cold leg break was used to investigate core and system response to a depressurization and reflood transient with ECC injection at the intact loop pump suction and broken loop cold leg. A reduced lower plenum volume was used for this test to more accurately represent the lower plenum of a PWR, based on system volume scaling. System flow was set to achieve a core fluid temperature differential of 65 0 F at a core power level of 1.44 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a slightly peaked radial power profile was used in the pressure vessel to simulate the predicted surface heat flux of nuclear fuel rods during a loss-of-coolant accident

  6. Experiment data report for Semiscale Mod-1 Test S-05-4 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Feldman, E.M.

    1977-03-01

    Recorded test data are presented for Test S-05-4 of the Semiscale Mod-1 alternate emergency core coolant injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-4 was conducted from initial conditions of 2266 psia and 543 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of each loop and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. The upper plenum coolant injection was scaled according to the heat stored in the metal mass of the upper plenum

  7. Condensation during gravity driven ECC: Experiments with PACTEL

    Energy Technology Data Exchange (ETDEWEB)

    Munther, R.; Kalli, H. [Lappeenranta Univ. of Technology (Finland); Kouhia, J. [Technical Research Centre of Finland, Lappeenranta (Finland)

    1995-09-01

    This paper provides the results of the second series of gravity driven emergency core cooling (ECC) experiments with PACTEL (Parallel Channel Test Loop). The simulated accident was a small break loss-of-coolant accident (SBLOCA) with a break in a cold leg. The ECC flow was provided from a core makeup tank (CMT) located at a higher elevation than the main part of the primary system. The CMT was pressurized with pipings from the pressurizer and a cold leg. The tests indicated that steam condensation in the CMT can prevent ECC and lead to core uncovery.

  8. ECC delivery to lower plenum under downcomer injection part 2. RELAP5 assessment

    International Nuclear Information System (INIS)

    Bang, Young Seok; Shin, An Dong; Kim, Hho Jung

    2000-01-01

    In the present study, the capability of the thermal-hydraulic codes, RELAP5/MOD3.2.2 gamma, in predicting the steam-water interaction and the related ECC delivery to lower plenum under downcomer injection condition during refill phase is evaluated using the experimental data of the UPTF Test 21A. The facility is modeled in detail, and the test condition simulated for code calculations. The calculation result is compared with the applicable measurement data and discussed for the pressure response, ECC bypass behavior, lower plenum delivery, global water mass distribution, and local behavior in downcomer

  9. Investigation of Characteristics of Impinging Jet for 1/5-Scale ECC injection

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Soo; Ko, Yung Joo; Bae, Hwang; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-05-15

    In ECCS of SMART reactor, safety injection pump discharges cooling water into the core to maintain the water level by filling the amount of loss of coolant under emergency situation such as SBLOCA. Once the ECCS starts to operate, the injected water will be impinged to the upper wall of core support barrel (CBS). And the water will fall along the wall forming liquid film or droplets as shown in Fig. 1(b) due to high Reynolds number. The breakup and film flow will be bypassed by high temperature and pressure steam-water mixture cross flow from RCP discharge into the atmosphere through broken injection nozzle. Then, the flow phenomena in the downcomer is very complex situation with including jet impingement, jet breakup, liquid entrainment, steam condensation, counter-current flow and etc. In this study, the hydraulic features of impinging jet were investigated through visualization for full scale test for simulation of SMART ECC jet and SWAT test of 1/5 simulated test for ECCS of SMART reactor and measurement of the film width. And the scaling method for SWAT test was discussed considering jet break up and other phenomena

  10. Method of injecting cooling water in emergency core cooling system (ECCS) of PWR type reactor

    International Nuclear Information System (INIS)

    Sobajima, Makoto; Adachi, Michihiro; Tasaka, Kanji; Suzuki, Mitsuhiro.

    1979-01-01

    Purpose: To provide a cooling water injection method in an ECCS, which can perform effective cooling of the reactor core. Method: In a method of injecting cooling water in an ECCS as a countermeasure against a rupture accident of a pwr type reactor, cooling water in the first pressure storage injection system is injected into the upper plenum of the reactor pressure vessel at a set pressure of from 50 to 90 atg. and a set temperature of from 80 to 200 0 C, cooling water in the second pressure storage injection system is injected into the lower plenum of the reactor pressure vessel at a pressure of from 25 to 60 atg. which is lower than the set pressure and a temperature less than 60 0 C, and further in combination with these procedures, cooling water of less than 60 0 C is injected into a high-temperature side piping, in the high-pressure injection system of upstroke of 100 atg. by means of a pump and the low-pressure injection system of upstroke of 20 atg. also by means of a pump, thereby cooling the reactor core. (Aizawa, K.)

  11. Water-hammer in the cold leg during an SBLOCA due to cold ECCS injection

    International Nuclear Information System (INIS)

    Ortiz, M.G.; Ghan, L.S.

    1991-01-01

    Water-hammer might occur in the cold leg of pressurized water reactors (PWR) during small break loss-of-coolant accidents (SBLOCA's), when cold emergency core cooling system (ECCS) water is injected into a pipe that may be partially filled with saturated steam. The water may mix with the steam and cause it to condense abruptly. Depending on the flow regime present, slugs of liquid may then be accelerated towards each other or against the piping structure. The possibility of this phenomenon is of concern to us because it may become a dominant phenomenon and change the character of the transient. In performing the code scaling, applicability, and uncertainty study (CSAU) on a SBLOCA scenario, we had to examine the possibility that the transient being analyzed could experience water-hammer and thus depart from the scope of the study. Two criteria for water-hammer initiation were investigated and tested using a RELAP5/MOD3 simulation of the transient. Our results indicated a very low likelihood of occurrence of the phenomenon. 8 refs., 6 figs

  12. Numerical study of hot-leg ECC injection into the upper plenum of a pressurized water reactor

    International Nuclear Information System (INIS)

    Daly, B.J.; Torrey, M.D.; Rivard, W.C.

    1981-01-01

    In certain pressurized water reactor (PWR) designs, emergency core coolant (ECC) is injected through the hot legs into the upper plenum. The condensation of steam on this subcooled liquid stream reduces the pressure in the hot legs and upper plenum and thereby affects flow conditions throughout the reactor. In the present study, we examine countercurrent steam-water flow in the hot leg to determine the deceleration of the ECC flow that results from an adverse pressure gradient and from momentum exchange from the steam by interfacial drag and condensation. For the parameters examined in the study, water flow reversal is observed for a pressure drop of 22 to 32 mBar over the 1.5 m hot leg. We have also performed a three-dimensional study of subcooled water injection into air and steam environments of the upper plenum. The ECC water is deflected by an array of cylindrical guide tubes in its passage through the upper plenum. Comparisons of the air-water results with data obtained in a full scale experiment shows reasonable agreement, but indicates that there may be too much resistance to horizontal flow about the columns because of the use of a stair-step representation of the cylindrical guide tube cross section. Calculations of flow past single columns of stair-step, square and circular cross section do indicate excessive water deeentrainment by the noncircular column. This has prompted the use of an arbitrary mesh computational procedure to more accuratey represent the circular cross-section guide tubes. 15 figures

  13. Experimental results of the SMART ECC injection performance with reduced scale of test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Shin, Yong Cheol; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    SMART pressurized water reactor type is different from the existing integral NSSS commercial pressurized water reactor system which is equipped with the main features. In addition, RCS piping is removed and the feature of the SBLOCA is a major design break accident. SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) test facility is to simulate the 2 inch SBLOCA of the SMART using with reduced scale. The Test was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this paper, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  14. Quick Look Report of the SMART ECC injection performance test I3

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    The objective of this report is to describe test results of the Test I3 simulating the 2 inch SBLOCA of the SMART using the SWAT test facility. The Test I3 was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this report, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  15. Experiment data report for semiscale Mod-1 test S-04-1 (baseline ECC test)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Collins, B.L.; Sackett, K.E.

    1976-09-01

    Recorded test data are presented for Test S-04-1 of the Semiscale Mod-1 Baseline ECC Test Series. This test is among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor system. Test S-04-1 was conducted from an initial cold leg fluid temperature of 542 0 F and an initial pressure of 2,263 psia. A simulated double-ended offset shear cold leg break was used to investigate the system response to a depressurization and reflood transient using system volume scaled coolant injection parameters. System flow was set to achieve a core fluid temperature differential of 66 0 F at a full core power of 1.6 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a flat radial power profile was used in the pressure vessel to simulate the effects of a nuclear core. During system depressurization, core power was reduced from the initial level of 1.6 MW in such a manner as to simulate the surface heat flux response of nuclear fuel rods until such time that departure from nucleate boiling might occur. Blowdown to the pressure suppression system was accompanied by simulated emergency core cooling injection into both the intact and broken loops. Coolant injection was continued until test termination at 200 seconds after initiation of blowdown

  16. Experiment data report for semiscale Mod-1 test S-04-2 (baseline ECC test)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Collins, B.L.; Sackett, K.E.

    1976-09-01

    Recorded test data are presented for Test S-04-2 of the Semiscale Mod-1 Baseline ECC test series. This test is among Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor system. Test S-04-2 was conducted from an initial cold leg fluid temperature of 542 0 F and an initial pressure of 2,263 psia. A simulated double-ended offset shear cold leg break was used to investigate the system response to a depressurization and reflood transient using emergency core coolant injection parameters based on downcomer volume scaling. System flow was set to achieve a core fluid temperature differential of 66 0 F at a full core power of 1.6 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a flat radial power profile was used in the pressure vessel to simulate the effects of a nuclear core. During system depressurization, core power was reduced from the initial level of 1.6 MW to simulate the surface heat flux response of nuclear fuel rods until such sime that departure from nucleate boiling might occur. Blowdown to the pressure suppression system was accompanied by simulated emergency core coolant injection into both the intact and broken loops. Coolant injection was continued until test termination at 200 seconds after initiation of blowdown. The purpose of the report is to make available the uninterpreted data from Test S-04-2 for future data analysis and test results reporting activities. The data, presented in the form of graphs in engineering units, have been analyzed only to the extent necessary to assure that they are reasonable and consistent

  17. Safety evaluation report on Westinghouse Electric Company ECCS evaluation model for plants equipped with upper head injection

    International Nuclear Information System (INIS)

    Lauben, G.N.; Wagner, N.H.; Israel, S.L.; McPherson, G.D.; Hodges, M.W.

    1978-04-01

    For plants which include an ice condenser containment concept, Westinghouse has planned an additional safety system known as the upper head injection (UHI) system to augment the emergency core cooling system. This system is comprised of additional accumulator tanks and piping arranged to supply cooling water to the top of the core during the blowdown period following a postulated large-break loss-of-coolant accident (LOCA). The objective of UHI is to add to the core cooling provided by the conventional emergency core cooling system (ECCS) and so permit operation at linear heat rates comparable to those permitted in plants utilizing the dry containment concept. In this way, plants which include the UHI system would have greater operating flexibility while still meeting the acceptance criteria as defined in paragraph 50.46 of 10 CFR Part 50. This review is concerned with those changes to the Westinghouse ECCS evaluation model that have been proposed for the UHI-LOCA model

  18. UPTF-TRAM test A3. Turn-over of the hot-leg injected ECC in the steam generator direction

    International Nuclear Information System (INIS)

    Tenckhoff; Brand, B.; Weiss, P.

    1993-06-01

    The UPTF TRAM test A3 was a separate effects test to investigate the interaction between the hot leg-injected ECC and the single-phase or two-phase natural circulation in the hot leg in the case of an SBLOCA in a PWR. The experimental investigation of 7 runs was mainly concentrated on the following phenomena: - Transport of hot leg injected ECC water to the upper plenum or in the direction of steam generator, depending on the loop mass flow, -Utilization of the condensation potential of ECC water, - Mixing of the saturated water with the ECC water, - Effect of hot leg injection on the flow phenomena in the hot leg, - Effect of pressure (3 and 15 bar) on the scaling and hence the verification of the scaling concept applied. A preliminary evaluation of the test is presented in the Quick Look Report. (orig.) [de

  19. Pressure vessel fracture studies pertaining to a PWR LOCA-ECC thermal shock: experiments TSE-1 and TSE-2

    International Nuclear Information System (INIS)

    Cheverton, R.D.

    1976-09-01

    The LOCA-ECC Thermal Shock Program was established to investigate the potential for flaw propagation in pressurized-water reactor (PWR) vessels during injection of emergency core coolant following a loss-of-coolant accident. Studies thus far have included fracture mechanics analyses of typical PWRs, the design and construction of a thermal shock test facility, determination of material properties for test specimens, and two thermal shock experiments with 0.53-m-OD (21-in.) by 0.15-m-wall (6-in.) cylindrical test specimens. The PWR calculations indicated that under some circumstances crack propagation could be expected and that experiments should be conducted for cracks that would have the potential for propagation at least halfway through the wall

  20. Heat and mass transfer in the stratified flow with ECCS injection

    International Nuclear Information System (INIS)

    Strubelj, L.; Tiselj, I.

    2007-01-01

    One of the most important problems in the light-water nuclear thermal-hydraulics is behaviour of the cold emergency core cooling water injected from the top or from the bottom into the horizontal section of the cold leg near the reactor vessel during the loss of coolant accident. The stratified flows appear where cold water is injected in partially or fully uncovered horizontal cold leg. The hot steam condenses on cold water surface what is also called direct contact condensation. Direct contact condensation and condensation induced water-hammer in a horizontal pipe were experimentally investigated at PMK-2 test facility of the Hungarian Atomic Energy Research Institute KFKI. The cold water is injected through small pipe into lower horizontal part of the section, and then water fills the vertical pipeline and floods the horizontal test section of the pipeline of the PMK-2 integral test facility. As liquid water floods the horizontal part of the pipeline, the counter current horizontally stratified flow is being observed. During the flooding of the pipeline, the steam-liquid interface area increases and therefore the steam condensation rate and the steam velocity also increase and can lead to bubble entrapment. Water level at one cross-section and four local void fraction and temperature at the top of horizontal test pipeline was measured and compared with simulation. Condensed steam increases the water temperature that is why the local temperature measurements are the most important information, from which condensation rate can be estimated, since mass of condensed steam was not measured. Numerical simulation of the experiment with thermal phase change is presented. Surface renewal concept with small eddies is used for calculation of condensation heat transfer coefficient. Two simulations were performed: simulation of whole experimental domain (lower horizontal, vertical and test horizontal pipeline) and simplified simulation of only upper horizontal test section

  1. Effects of high temperature ECC injection on small and large break BWR LOCA simulation tests in ROSA-III program (RUNs 940 and 941)

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Nakamura, Hideo; Kumamaru, Hiroshige; Anoda, Yoshinari; Yonomoto, Taisuke; Murata, Hideo; Tasaka, Kanji

    1990-03-01

    The ROSA-III program, of which principal results are summarized in a report of JAERI 1307, conducted small and large-break loss-of-coolant experiments (RUNs 940 and 941) with high water temperature of the emergency core cooling system (ECCS) are one of the parametric study with respect to the ECCS effect on core cooling. This report presents all the experiment results of these two tests and describes additional finding with respect to the hot ECC effects on core cooling phenomena. By comparing these two tests (water temperature of 393 K) with the standard ECC tests of RUNs 922 and 926 (water temperature of 313 K), it was found that the ECC subcooling variation had a small influence on the core cooling phenomena in 5 % small break tests but had larger influence on them in 200 % break tests. The ECC subcooling effects described in the previous report are reviewed and the temperature distribution in the pressure vessel is investigated for these four tests. (author)

  2. Diablo Canyon ECCS enhancements

    International Nuclear Information System (INIS)

    Lin, A.; Lee, T.P.; Walter, L.E.

    2004-01-01

    Diablo Canyon Power Plant (DCPP) operated by Pacific Gas and Electric Co. (PG and E) is a Westinghouse designed four loop plant. In recent years, several issues were identified regarding the compliance of the Emergency Core Cooling System (ECCS) surveillance tests to the ECCS analyses assumptions. These concerns are related mostly to the High Head Safety Injection (HHSI) and the Intermediate Head Safety Injection (IHSI) systems where the injection line throttle valves are adjusted during outage surveillance testing to ensure compliance with the Technical Specifications (TS). To resolve all of the identified issues PG and E performed an ECCS reanalysis and upgraded the ECCS surveillance test program and also had Westinghouse perform a containment reanalysis using their latest model. As a result of these plant specific enhancement efforts, DCPP widened the operating window for TS surveillance testing, lowered the ECCS pumps' acceptance performance curves, and re-gained Peak Clad Temperature (PCT) and containment peak pressure margins. These enhancements are generically applicable to other plants and are addressed in this paper. (author)

  3. Pressure vessel fracture studies pertaining to a PWR LOCA-ECC thermal shock: experiments TSE-3 and TSE-4 and update of TSE-1 and TSE-2 analysis

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Bolt, S.E.

    1977-01-01

    The LOCA-ECC Thermal Shock Program was established to investigate the potential for flaw propagation in pressurized-water reactor (PWR) vessels during injection of emergency core coolant following a loss-of-coolant accident. Studies thus far have included fracture mechanics analyses of typical PWRs, the design and construction of a thermal shock test facility, determination of material properties for test specimens, and four thermal shock experiments with 0.53-m-OD (21-in.) by 0.15-m-wall (6-in.) cylindrical test specimens. In the first experiment, initiation was not expected and did not occur, although there was a small amount of subcritical crack growth. In the second experiment, initiation of a semicircular flaw took place as expected; the final length along the surface was about four times the initial length, but there was no radial growth. The third and fourth experiments were similar, and the long axial flaw initiated in good agreement with predictions

  4. Direct ECC bypass phenomena in the MIDAS test facility during LBLOCA reflood phase

    International Nuclear Information System (INIS)

    Yun, B. J.; Kweon, T. S.; Ah, D. J.; Ju, I. C.; Song, C. H.; Park, J. K.

    2001-01-01

    This paper describes the experimental results of ECC Direct Bypass Phenomena in the downcomer during the late reflood phase of LBLOCA of the reactor that adopts Direct Vessel Injection as a ECC system. The experiments have been performed in MIDAS test facility using superheated steam and water. The test condition was determined, based on the preliminary analysis of TRAC code, from modified linear scaling method of 1/4.93 length scale. To measure the direct bypass fraction according to the nozzle location, separate effect tests have been performed in case of DVI-4(farthest from broken cold leg) injection, DVI-2(closest to broken cold leg) injection, and DVI-2 and 4 injection, respectively. Also the test was carried out varying the steam flow rate greatly to investigate the effect of steam flow rate on the direct bypass fraction of ECC water. Test results show that the direct bypass fraction of ECC water depends significantly on the injected steam mass flow rate. DVI-4 tests show that the direct bypass fraction increases drastically as the steam flow rate increases. However, in DVI-2 test most of the injected ECC water penetrates into lower downcomer. The direct bypass characteristic in each of DVI-2 and DVI-4 tests is reflected into the direct bypass characteristic curve of DVI-2 and 4 test. The steam condensation reaches to the theoretically allowable maximum value

  5. A study of ECC water bypass reduction technology for an improvement of core cooling capability

    International Nuclear Information System (INIS)

    Song, C. G.; Kwon, T. S.; Yun, B. J.

    2006-02-01

    The research for the reduction of ECC water bypass fraction was mainly performed to develop the flow mechanisms that ECC water can penetrate more effectively into a lower downcomer. Evaluation were carried out for the effect of major parameters on the bypass of ECC water in the downcomer with DVI. The following various physical models were derived for the reduction of the bypass fraction of ECC water: models of changing DVI injection angle, models of rearranging relative angles of DVI nozzles, model of grooved-and-subchannel type core barrel, model of dual core barrel. CFD analysis and MARS design verification were performed for the derived models as a first step performance estimation. Through out air-water verification experiments, quantitative evaluation were performed for each model, and three most efficient models were suggested. Examination were carried out for the requirement of structural modification and the change in structural integrity due to the adoption of one of the schemes

  6. Advanced DVI for ECC direct bypass mitigation

    International Nuclear Information System (INIS)

    Kwon, Tae-Soon; Song, Chul-Hwa; Baek, Won-Pil

    2009-01-01

    An ECC direct bypass fraction during a late reflood phase of a LBLOCA is strongly dependent on the characteristics of the cross flow and the geometrical configuration of a DVI in the downcomer of a pressurized light water reactor. The important design parameters of a DVI are the elevation, the azimuthal angle, and the separator to prevent a steam-water interaction. An ECC sub-channel to separate or to isolate an ECC water from a high-speed cross flow is one of the important design features to mitigate the ECC bypass phenomena. A dual core barrel cylinder as an ECC flow separator is located between a reactor vessel and a core barrel outer wall in the downcomer annulus. A new narrow gap between the core barrel and the additional dual core barrel plays the role of a downward ECC flow channel or an ECC flow separator in a high-speed cross flow field of the downcomer annulus. The flow zone around a broken cold leg in the downcomer annulus has the role of a high ECC direct bypass due to a strong suction force while the wake zone of a hot leg has the role of an ECC penetration. Thus, the relative azimuthal angle of the DVI nozzle from the broken cold leg is an important design parameter. A large azimuthal angle from a cold leg to a hot leg needs to avoid a high suction flow zone when an ECC water is being injected. The other enhancing mechanism of an ECC penetration is a grooved core barrel which has small rectangular-shaped grooves vertically arranged on the core barrel wall of the reactor vessel downcomer annulus. These grooves have the role for a generation of a vortex induced by a high-speed cross flow. Since the stagnant flow in a lateral direction and rotational vortex provides the pulling force of an ECC drop or film to flow down into the lower downcomer annulus by gravity, the ECC direct bypass fraction is reduced when compared to the current design of a smoothed wall. An open channel of grooves generates a stagnant vortex, while a closed channel of grooves

  7. Simulation of a large break loss of coolant (LBLOCA), without actuation of the emergency injection systems (ECCS) for a BWR-5

    International Nuclear Information System (INIS)

    Cardenas V, J.; Mugica R, C. A.; Lopez M, R.

    2015-09-01

    In this paper the analysis of scenario for the loss of coolant case was realized with break at the bottom of a recirculation loop of a BWR-5 with containment type Mark II and a thermal power of 2317 MWt considering that not have coolant injection. This in order to observe the speed of progression of the accident, the phenomenology of the scenario, the time to reach the limit pressure of containment venting and the amount of radionuclides released into the environment. This simulation was performed using the MELCOR code version 2.1. The scenario posits a break in one of the shear recirculation loops. The emergency core cooling system (ECCS) and the reactor core isolation cooling (Rcic) have not credit throughout the event, which allowed achieve greater severity on scenario. The venting of the primary containment was conducted via valve of 30 inches instead of the line of 24 inches of wet well, this in order to have a larger area of exhaust of fission products directly to the reactor building. The venting took place when the pressure in the primary containment reached the 4.5 kg/cm 2 and remained open for the rest of the scenario to maximize the amount released of radionuclides to the atmosphere. The safety relief valves were considered functional they do not present mechanical failure or limit their ability to release pressure due to the large number of performances in safety mode. The results of the analysis covers about 48 hours, time at which the accident evolution was observed; behavior of level, pressure in the vessel and the fuel temperature profile was analyzed. For progression of the scenario outside the vessel, the pressure and temperature of the primary containment, level and temperature of the suppression pool, the hydrogen accumulation in the container and the radionuclides mass released into the atmosphere were analyzed. (Author)

  8. ECC cusp analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pregliasco, R.G. (Centro Atomico Bariloche and CONICET, S.C. de Bariloche (Argentina)); Garibotti, C.R. (Centro Atomico Bariloche and CONICET, S.C. de Bariloche (Argentina)); Barrachina, R. (Centro Atomico Bariloche and CONICET, S.C. de Bariloche (Argentina))

    1994-03-01

    We measured the ionization double differential cross section for the H[sup +][yields]He 100 keV collision at the proximities of the ECC cusp and all around 0 . We propose an angular function expansion and a procedure for data analysis. We demonstrate that, in this way, the difficulties and shortcomings presented in the standard data processing are overcome. In our experimental results we distinguish the presence of characteristic shapes for the ionization depending on whether the module of the electron velocity is greater or smaller than the projectile velocity. (orig.)

  9. Method and device for controlling ECCS

    International Nuclear Information System (INIS)

    Ikeda, Takashi; Kataoka, Yoshiyuki; Murase, Michio.

    1986-01-01

    Purpose: To accomplish reactor cooling without exposing fuel assemblies out of the coolant and also without inducing counter-current flow (CCFL) brake likely to be caused by excess injection of water even in case of malfunction of one system in a loss-of-coolant accident. Method: In a BWR type reactor having more than two independent ECCS, the lower plenum water level is measured and when the lower plenum is full of water, the ECCS are kept in a fully closed state, and reversely when the lower plenum is not full of water, more coolant than the lost quantity of water will be injected into the plenum at a higher pressure than a pressure at which fuel rods just begin to be exposed to the steam phase. The subcool energy of the emergency coolant to be injected is determined by the decay heat of the core and the change rate of a container pressure. However, the quantity of the emergency coolant is controlled such that the subcool energy will always become less than the overheating energy in the core range and the lower plenum range, thus improving safety and enabling the removal of a prior-art ECCS. (Kamimura, M.)

  10. Emergency response guide-B ECCS guideline evaluation analyses for N reactor

    International Nuclear Information System (INIS)

    Chapman, J.C.; Callow, R.A.

    1989-07-01

    INEL conducted two ECCS analyses for Westinghouse Hanford. Both analyses will assist in the evaluation of proposed changes to the N Reactor Emergency Response Guide-B (ERG-B) Emergency Core System (ECCS) guideline. The analyses were a sensitivity study for reduced-ECCS flow rates and a mechanistically determined confinement steam source for a delayed-ECCS LOCA sequence. The reduced-ECCS sensitivity study established the maximum allowable reduction in ECCS flow as a function of time after core refill for a large break loss-of-coolant accident (LOCA) sequence in the N Reactor. The maximum allowable ECCS flow reduction is defined as the maximum flow reduction for which ECCS continues to provide adequate core cooling. The delayed-ECCS analysis established the liquid and steam break flows and enthalpies during the reflood of a hot core following a delayed ECCS injection LOCA sequence. A simulation of a large, hot leg manifold break with a seven-minute ECCS injection delay was used as a representative LOCA sequence. Both analyses were perform using the RELAP5/MOD2.5 transient computer code. 13 refs., 17 figs., 3 tabs

  11. Simulation of a large break loss of coolant (LBLOCA), without actuation of the emergency injection systems (ECCS) for a BWR-5; Simulacion de un escenario de perdida de refrigerante grande (LBLOCA), sin actuacion de los sistemas de inyeccion de emergencia (ECCS) para un reactor BWR-5

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas V, J.; Mugica R, C. A.; Lopez M, R., E-mail: jaime.cardenas@cnsns.gob.mx [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico)

    2015-09-15

    In this paper the analysis of scenario for the loss of coolant case was realized with break at the bottom of a recirculation loop of a BWR-5 with containment type Mark II and a thermal power of 2317 MWt considering that not have coolant injection. This in order to observe the speed of progression of the accident, the phenomenology of the scenario, the time to reach the limit pressure of containment venting and the amount of radionuclides released into the environment. This simulation was performed using the MELCOR code version 2.1. The scenario posits a break in one of the shear recirculation loops. The emergency core cooling system (ECCS) and the reactor core isolation cooling (Rcic) have not credit throughout the event, which allowed achieve greater severity on scenario. The venting of the primary containment was conducted via valve of 30 inches instead of the line of 24 inches of wet well, this in order to have a larger area of exhaust of fission products directly to the reactor building. The venting took place when the pressure in the primary containment reached the 4.5 kg/cm{sup 2} and remained open for the rest of the scenario to maximize the amount released of radionuclides to the atmosphere. The safety relief valves were considered functional they do not present mechanical failure or limit their ability to release pressure due to the large number of performances in safety mode. The results of the analysis covers about 48 hours, time at which the accident evolution was observed; behavior of level, pressure in the vessel and the fuel temperature profile was analyzed. For progression of the scenario outside the vessel, the pressure and temperature of the primary containment, level and temperature of the suppression pool, the hydrogen accumulation in the container and the radionuclides mass released into the atmosphere were analyzed. (Author)

  12. ECCS Operability With One or More Subsystem(s) Inoperable

    International Nuclear Information System (INIS)

    Swantner, Stephen R.; Andrachek, James D.

    2002-01-01

    Plant Technical Specifications are issued by the US NRC to ensure that safe nuclear power plant operation is maintained within the assumptions for parameters and Structures, Systems, and Components (SSCs) made in the plant safety analysis reports. The Technical Specifications are made up of Limiting Conditions for Operation (LCOs), which are the minimum set of requirements that must be met based on the assumptions of the safety analysis, Actions, which are the remedial or compensatory actions that must be taken if the LCO is not met, and Surveillance Requirements, that demonstrate that the LCO is met. The Technical Specification Actions contain Completion Times (CTs) which are the time within which remedial actions must be taken, in the event that the LCO is not met. The Improved Standard Technical Specifications (ISTS) for Westinghouse plants are contained in NUREG-1431, Revision 2. Condition A of Technical Specification 3.5.2 (ECCS- Operating) in NUREG-1431, Revision 2, allows components to be taken out of service for up to 72 hours, as long as 100% of the ECCS flow equivalent to a single Operable ECCS train exists. Condition A would allow, for example, the A train low head safety injection (LHSI) and the B train high head safety injection (HHSI) pumps to be taken out of service (for 72 hours) as long as it could be demonstrated that the remaining components could provide 100% train equivalent flow capacity. The 'cross-training' allowed by this Condition in the ISTS provides flexibility when performing routine pre-planned preventive maintenance and testing, as well as during emergent corrective maintenance and testing associated with random component inoperabilities. Without this flexibility, a unit would have to initiate a plant shutdown within 1 hour, if component(s) were inoperable in different trains. In order to implement this flexibility, the various combinations of components in opposite trains must be evaluated to determine whether 100% of the ECCS flow

  13. Two-phase flow dynamics in ECC

    International Nuclear Information System (INIS)

    Albraaten, P.J.

    1981-07-01

    The present report summarizes the achievements within the project ''Two-phase Systems and ECC''. The results during 1978 - 1980 are accounted for in brief as they have been documented in earlier reports. The results during the first half of 1981 are accounted for in greater detail. They contain a new model for the Basset force and test runs with this model using the test code RISQUE. Furthermore, test runs have been performed with TRAC-PD2 MOD 1. This code was implemented on Edwards Pipe Blowdown experiment (a standard test case) and UC-Berkeley Reflooding experiment (a non-standard test case.) (Auth.)

  14. Evaluation of ECC bypass data with a nonlinear constrained MLE technique

    International Nuclear Information System (INIS)

    Bishop, T.A.; Collier, R.P.; Kurth, R.E.

    1980-01-01

    Recently, Battelle's Columbus Laboratories have been involved in scale-model tests of emergency core cooling (ECC) systems for hypothesized loss-of-coolant accidents in pressurized water reactors (PWR). These tests are intended to increase our understanding of ECC bypass, which can occur when steam flow from the reactor core causes the emergency coolant to bypass the core and flow directly to the break. One objective of these experiments is the development of a correlation which relates the flow rate of water penetrating to the core to the steam flow rate. This correlation is derived from data obtained from a 2/15 scale model PWR at various ECC water injection rates, subcoolings, pressures, and steam flows. The general form of the correlation being studied is a modification of the correlation first proposed by Wallis. The correlation model is inherently nonlinear and implicit in form, and the model variables are all subject to error. Therefore, the usual nonlinear analysis techniques are inappropriate. A nonlinear constrained maximum-likelihood-estimation technique has been used to obtain estimates of the model parameters, and a Battelle-developed code, NLINMLE, has been used to analyze the data. The application of this technique is illustrated by sample calculations of estimates of the model parameters and their associated confidence intervals for selected experimental data sets. 5 figures, 7 tables

  15. Passive safety injection experiments and analyses (PAHKO)

    International Nuclear Information System (INIS)

    Tuunanen, J.

    1998-01-01

    PAHKO project involved experiments on the PACTEL facility and computer simulations of selected experiments. The experiments focused on the performance of Passive Safety Injection Systems (PSIS) of Advanced Light Water Reactors (ALWRs) in Small Break Loss-Of-Coolant Accident (SBLOCA) conditions. The PSIS consisted of a Core Make-up Tank (CMT) and two pipelines (Pressure Balancing Line, PBL, and Injection Line, IL). The examined PSIS worked efficiently in SBLOCAs although the flow through the PSIS stopped temporarily if the break was very small and the hot water filled the CMT. The experiments demonstrated the importance of the flow distributor in the CMT to limit rapid condensation. The project included validation of three thermal-hydraulic computer codes (APROS, CATHARE and RELAP5). The analyses showed the codes are capable to simulate the overall behaviour of the transients. The detailed analyses of the results showed some models in the codes still need improvements. Especially, further development of models for thermal stratification, condensation and natural circulation flow with small driving forces would be necessary for accurate simulation of the PSIS phenomena. (orig.)

  16. Impurity pellet injection experiments at TFTR

    International Nuclear Information System (INIS)

    Marmar, E.S.

    1991-01-01

    Impurity (Li and C) pellet experiments, which began at TFTR in 1989, and are expected to continue at least through 1991, have continued to produce new and significant results. The most significant of these are: (1) improvements in TFTR supershots after wall-conditioning by Li pellet injection; (2) accurate measurements of the pitch angle profiles of the internal magnetic field using the polarization angles of line emission from Li + in the pellet ablation cloud; and (3) initial measurements of pitch angle profiles using the tilt of the LI + emission region of the ablation cloud which is stretched out along the field lines

  17. Evaluation of mispositioned ECCS valves

    International Nuclear Information System (INIS)

    Hill, R.A.; O'Brien, J.F.; McIntire, D.C.; Barlow, R.T.

    1977-09-01

    In October of 1975, Westinghouse submitted NS-CE-787, dated October 17, 1975, to the Nuclear Regulatory Commission (NRC) and entered into discussions with them concerning the spurious movement of certain motor-operated valves (MOV's) in the Emergency Core Cooling System (ECCS) to a position defeating the ECCS function at a time when this function is required. On November 25, 1975, the discussion turned to the possible movement of a manually controlled, motor-operated valve due to a fault in its electrical circuitry and the NRC staff expressed concerns about other possible failure modes that might lead to such a valve movement. The NRC meeting minutes document these concerns. This report is an item-by-item response to the concerns expressed by the NRC staff at that meeting and incorporates the original electrical fault analysis

  18. Pellet injection experiments on the TFR Tokamak

    International Nuclear Information System (INIS)

    1987-02-01

    Single pellet injection experiments have been carried out on TFR with the aim to improve the experimental knowledge of ablation physical processes and also to get a better description of the heat and matter transport during and after pellet evaporation. Ablation clouds have been photographed, providing experimental penetration depths in rough agreement with the neutral shielding model. Observation of striations in the cloud has led to an experimental determination of the safety factor profile. Parameters of the plasma in the ablation cloud have been spectroscopically determined. Fast heat transport has been evidenced during pellet evaporation (∼ 100 μs) which exhibits some features of minor or major disruptions (appearance of a m = 1, n = 1 island on the q = 1 surface, bursts of density fluctuations, comparable heat diffusivity, ...). Matter transport takes place on a larger time scale (∼ 10 ms). This long temporal relaxation is well accounted for by the 1D-MAKOKOT computer code without changing the transport coefficients after pellet injection. Heat and matter transport are affected by the presence of the m = 1, n = 1 island on the q = 1 surface

  19. Impurity pellet injection experiments at TFTR

    International Nuclear Information System (INIS)

    Marmar, E.S.

    1992-01-01

    Impurity (Li and C) pellet injection experiments on TFTR have produced a number of new and significant results. (1) We observe reproducible improvements of TFTR supershots after wall-conditioning by Li pellet injection ('lithiumization'). (2) We have made accurate measurements of the pitch angle profiles of the internal magnetic field using two novel techniques. The first measures the internal field pitch from the polarization angles of Li + line emission from the pellet ablation cloud, while the second measures the pitch angle profiles by observing the tilt of the cigar-shaped Li + emission region of the ablation cloud. (3) Extensive measurements of impurity pellet penetration into plasmas with central temperatures ranging from ∼0.3 to ∼7 keV have been made and compared with available theoretical models. Other aspects of pellet cloud physics have been investigated. (4) Using pellets as a well defined perturbation has allowed study of transport phenomena. In the case of small pellet perturbations, the characteristics of the background plasmas are probed, while with large pellets, pellet induced effects are clearly observed. These main results are discussed in more detail in this paper

  20. BWR fuel experience with zinc injection

    International Nuclear Information System (INIS)

    Levin, H.A.; Garcia, S.E.

    1995-01-01

    In 1982 a correlation between low primary recirculation system dose rates in BWR's and the presence of ionic zinc in reactor water was identified. The source of the zinc was primarily from Admiralty brass condensers. Plants with brass condensers are called ''natural zinc'' plants. Brass condensers were also a source of copper that was implicated in crude induced localized corrosion (CILC) fuel failures. In 1986 the first BWR intentionally injected zinc for the benefits of dose rate control. Although zinc alone was never implicated in fuel degradation of failures, a comprehensive fuel surveillance program was initiated to monitor fuel performance. Currently there are 14 plants that are injecting zinc. Six of these plants are also on hydrogen water chemistry. This paper describes the effect on both Zircaloy corrosion and the cruding characteristics as a result of these changes in water chemistry. Fuel rod corrosion was found to be independent of the specific water chemistry of the plants. The corrosion behavior was the same with the additions of zinc alone or zinc plus hydrogen and well within the operating experience for fuel without either of these additions. No change was observed in the amounts of crude deposited on the fuel rods, both for the adherent and loosely held deposits. One of the effects of the zinc addition was the trend to form more of the zinc rich iron spinel in the fuel deposits rather than the hematite deposits that are predominantly formed with non additive water chemistry

  1. Development of Calculation Algorithm for ECCS Kinematic Shock

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung-Chan; Yoon, Duk-Joo; Ha, Sang-Jun [KHNP-CRI, Daejeon (Korea, Republic of)

    2014-10-15

    The void fraction of inverted U-pipes in front of SI(Safety Injection) pumps impact on the pipe system of ECCS(Emergency Core Cooling Systems). This phenomena is called as 'Kinematic Shock'. The purpose of this paper is to achieve the more exactly calculation when the kinematic shock is calculated by simplified equation. The behavior of the void packet of the ECCS pipes is illustrated by the simplified (other name is kinematic shock equation).. The kinematic shock is defined as the depth of total length of void clusters in the pipes of ECCS when the void cluster is continually reached along the part of pipes in vertical direction. In this paper, the simplified equation is evaluated by comparing calculation error each other.]. The more exact methods of calculating the depth of the kinematic shock in ECCS is achieved. The error of kinematic shock calculation is strongly depended on the calculation search gap and the order of Taylor's expansion. From this study, to select the suitable search gap and the suitable calculation order, differential root method, secant method, and Taylor's expansion form are compared one another.

  2. Method of controlling ECCS system in reactors

    International Nuclear Information System (INIS)

    Oohashi, Hideaki; Ikehara, Morihiko.

    1982-01-01

    Purpose: To eliminate the risk of misoperation and thereby improve the reliability of ECCS system upon accident. Method: ECCS system for nuclear reactor is automatically started by either of signals from a water level detector in a pressure vessel or from a pressure detector in a reactor container. Further, the ECCS system is started or stopped by the manual operation irrespective of the signals, and the signals from the pressure detector are isolated from the ECCS-starting signal by the contacts which actuate interlocked with the stopping operation of the manual operation switch. Then, after stopping the ECCS system by the manual operation, the ECCS system is started by the signals from the water level detector irrespective of the signals from the pressure detector. (Seki, T.)

  3. Design Development of SMART ECC Water Asymmetric Two-phase choking test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Shin, Yong Cheol; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    SMART pressurized water reactor type is different from the existing integral NSSS commercial pressurized water reactor system which is equipped with the main features. In addition RCS piping is removed and the feature of the SBLOCA is a major design break accident. The TASS / SMR code is analyzed SMART SBLOCA. In order to verify analysis code, SMART analysis for verification of conservatism is promoting using data for experiments with Integral Effect Test and Separate Effect. In this paper, the design feature of the SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) is described. SWAT is linearly reduced to a 1/5 ratio while the geometrical shape is conserved. In major shape of SMART ECC injection performance test, distortions which caused by gravitational effects are minimized. Because both the emergency core cooling water injection nozzle height and the break nozzle height match the RCP Suction Nozzle height in test section of the main forms. The main part of the test section is SG-side upper down-comer. The boundary conditions are saturated steam and water flow condition and drain flow rate to control the collapsed water level in the down-comer

  4. LOFT ECC Pitot Tube and Thermocouple Rake Penetration thermal analysis

    International Nuclear Information System (INIS)

    Tolan, B.J.

    1977-01-01

    A thermal analysis of the LOFT ECC Pitot Tube and Thermocouple Rake Penetration was performed using COUPLE, a two-dimensional finite element computer code. Four transients which conservatively cover all transients the rake will be exposed to were included in this analysis in order to comply with the ASME Code Section III requirements. The transients conservatively cover hot and cold leg operation, and nuclear and nonnuclear operation. The four transients include the LOCE with ECC injection transient, the single control rod drop transient, the scram transient, and the heatup with 0 to 100% load change transient. Temperature distributions in the rake were obtained for each of the four transients and several plots of node temperatures vs. time are given

  5. Safety verification for the ECCS driven by the electrically 4 trains during LBLOCA reflood phase using ATLAS

    International Nuclear Information System (INIS)

    Park, Yusun; Park, Hyun-sik; Kang, Kyoung-ho; Choi, Nam-hyun; Min, Kyoung-ho; Choi, Ki-yong

    2014-01-01

    Highlights: • Safety improvement by adopting 4 train emergency core cooling system was validated experimentally. • General thermal hydraulic behaviors of the system during LBLOCA reflood phase were successfully demonstrated. • Key parameters such as the liquid levels, the PCTs, the quenching time, and the ECC bypass ratios were investigated. • Asymmetric effects of the different combination of safety injection were negligible during the reflood period. - Abstract: The APR1400 is equipped with four safety injection pumps driven by two emergency diesel generators. However, the design has been changed so that the four safety injection pumps are driven by 4 emergency diesel generators during the design certification process from the U.S. NRC. Thus, 4 safety injection pumps (SIPs) are completely independent electrically and mechanically and three safety injection pumps are available in a single failure condition. This design change could have a certain effects on the thermal-hydraulic phenomenon occurring in the downcomer region during the late reflood phase of a large break loss of coolant accident (LBLOCA). Thus, in this study, a verification experiment for the reflood phase of a LBLOCA was performed to evaluate the core cooling performance of the 4 train emergency core cooling system (ECCS) with an assumption of a single failure. And the different combinations of three SIPs positions were tested to investigate the asymmetric effects on the reactor core cooling performance. The overall experimental results revealed the typical thermal–hydraulic trends expected to occur during the reflood phase of a large-break LOCA scenario for the APR1400. Experiment with the injection of three SIPs showed a faster core quenching time and lower bypass ratio than that of the case in which two SIPs were injected. The RPV wall temperature distributions showed the similar trend in spite of the different SIP combinations

  6. The Heat Exchanger for Passive Part ECCS of WWER-1000 on Base of the Thermo siphons

    International Nuclear Information System (INIS)

    Kirov, V.; Chulkin, O.

    2008-01-01

    One of NPP's systems providing safe operation is the system of emergency core cooling system (ECCS), which primary function in accidents is to flood the nuclear reactor core and to assure the sub critical condition and core cooling. At injection of cold water in reactor thermal stresses and thermal fatigue in the vessel cladding and constructional materials are arise. Low temperature of the water injected in reactor is a reason of occurrence of these undesirable consequences. Some variants of the water heating in accumulators of ECCS are considered. Now at Ukrainian NPPs the electrical heating in accumulators is used. Electrical heaters create the essential additional loading to diesel generators at imposing of two accidents - the large break and losses of power supplies on own needs. It is offered to use a heater in accumulators that working by a principle two-phase thermal siphon which advantages is: small dimensions, small delay and design reliability. In such heat exchanger the heating medium is a direct steam and the heated up medium is water with boric acid from accumulators of ECCS. Under requirements of the service regulations of ECCS accumulators it is necessary to guarantee injected water heating up to 90 ?? in case of a small break and to 150 ?? in case of the large break. Results of calculations for different external diameters of a tube of thermal siphon which have allowed to define the constructive sizes of heat exchanger, providing necessary conditions for required functioning of passive part ECCS are submitted The calculation and analysis of operating modes of the changed circuit of passive part ECCS for various accidents is carried out. The calculated pressure drop indicates that changes do not have essential influence on system work as a whole. Thus, the submitted decision provides the increase of reliability of ECCS at small and large breaks accidents, i.e. in all modes stipulated by the project.(author)

  7. Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS

    International Nuclear Information System (INIS)

    Hanson, G.H.

    1978-01-01

    The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. A policy involves disabling the automatic-actuation of the LOFT ECCS, but still retaining the manual actuation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 33 kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS. For the operating power of the L2-2 Experiment, the required decay-periods (with operating periods of 40 and 2000 hours) are about 21 and 389 hours, respectively. With operating periods of 40 and 2000 hours at Core-I full power, the required decay-periods are about 42 and 973 hours, respectively. After these decay periods the automatic actuation of the LOFT ECCS can be disabled assuming a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS. The automatic and manual lineup of the ECCS may be waived if decay power is less than 11 kW

  8. Historical information on ORNL proposals for ECCS testing

    International Nuclear Information System (INIS)

    1976-01-01

    This document contains a compilation of the correspondence and preliminary report which the Oak Ridge National Laboratory submitted to the U.S. Atomic Energy Commission on the subject of in situ testing of emergency core cooling systems (ECCS) in pressurized water reactors. Most of the correspondence, which was prepared four to five years ago, deals with an ORNL proposal to evaluate the merits of conducting an in situ ECCS test in a full-scale commercial power plant. The end result of this work was to be a report in which the feasibility of conducting such an experiment would be discussed and a ''rough'' cost estimate provided. In support of this proposal, ORNL prepared a brief preliminary prospectus which identified some of the key questions that were to be addressed should the evaluation study be funded

  9. Experiments on Li pellet injection into Heliotron E

    International Nuclear Information System (INIS)

    Sergeev, V.Yu.; Khlopenkov, K.V.; Kuteev, B.V.; Sudo, S.; Kondo, K.; Zushi, H.; Besshou, S.; Sano, F.; Okada, H.; Mizuuchi, T.; Nagasaki, K.; Obiki, T.; Kurimoto, Y.

    1998-01-01

    Li pellets of large size were injected into electron cyclotron resonance (ECR) heated plasmas and neutral beam injection (NBI) heated plasmas of Heliotron E. The discharge behaviour, pellet ablation and wall conditioning were studied. The electron pressure is doubled after injection into the NBI plasma and remains unchanged in the case of ECR heating. This may be due to the energy exchange between the electrons and thermal ions with the fast ions from the neutral beam. The observed discrepancy between the experimental and modelled ablation rates may be caused by both the plasma cooling due to pellet ablatant and the ablation stimulated by the fast ions in the NBI-heated regime and by the fast electrons in the ECR-heated regime. In preliminary experiments on wall conditioning by Li pellet injection, no improvement of plasma performance after Li pellet injection was observed in the divertor or limiter configuration, with the limiter radii r L =24-25cm. (author)

  10. Preliminary pellet injection experiment in the Gamma 10 tandem mirror

    Energy Technology Data Exchange (ETDEWEB)

    Kawamori, Eiichirou; Tamano, Teruo; Nakashima, Yousuke; Yoshikawa, Masayuki; Kobayashi, Shinji; Cho, Teruji; Ishii, Kameo; Yatsu, Kiyoshi [Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki (Japan); Mase, Atsushi [Advanced Sceince and Technology Center for Cooperative Research, Kyushu University, Kasuga, Fukuoka (Japan)

    2000-07-01

    In the GAMMA 10 tandem mirror, pellet injection experiments have been started as a solution for the density limit problem. This is the first pellet injection experiment in open systems. We describe the possibilities of confinement of pellet fueled particles. For that, we measure the number of end loss particles and compare them with pellet fueled ones in various conditions of confining potentials. The deterioration of confining potential with the pellet injection is a fundamental issue. The results show that the ion confining potential recover faster than central electron temperature due to thermal barrier. We also consider the operating space for fueling method. It is demonstrated that the operating space for pellet injection exceeds gas fueled one on hot ion mode plasmas. (author)

  11. Disruption mitigation experiment with massive gas injection of HT-7

    International Nuclear Information System (INIS)

    Zhuang Huidong; Zhang Xiaodong

    2013-01-01

    Massive gas injection (MGI) is a promising method on disruption mitigation. The working principle of the fast valve for disruption mitigation was introduced. The disruption mitigation experiments by MGI on HT-7 were described. The experiment shows that the impurities radiation is improved by injecting appropriate amount of gas, and the current quench rate is slow down, so the electromagnetic load on the device is mitigated. The experiments show that the fast valve can completely satisfy the requirement of disruption mitigation on HT-7. (authors)

  12. Initial Results from Coaxial Helicity Injection Experiments in NSTX

    International Nuclear Information System (INIS)

    Raman, R.; Jarboe, T.R.; Mueller, D.; Schaffer, M.J.; Maqueda, R.; Nelson, B.A.; Sabbagh, S.; Bell, M.; Ewig, R.; Fredrickson, E.; Gates, D.; Hosea, J.; Ji, H.; Kaita, R.; Kaye, S.M.; Kugel, H.; Maingi, R.; Menard, J.; Ono, M.; Orvis, D.; Paolette, F.; Paul, S.; Peng, M.; Skinner, C.H.; Wilgen, W.; Zweben, S.

    2001-01-01

    Coaxial Helicity Injection (CHI) has been investigated on the National Spherical Torus Experiment (NSTX). Initial experiments produced 130 kA of toroidal current without the use of the central solenoid. The corresponding injector current was 20 kA. Discharges with pulse lengths up to 130 ms have been produced

  13. Pellet injection experiments on tokamaks in ASIPP, China

    International Nuclear Information System (INIS)

    Yang, Y.; Bao, Y.; Li, J.; Gu, X.; He, Y.

    2001-01-01

    Pellet injection has been proved to be an effective method for deep fueling of fusion devices. Improvements of both the particle confinement and the energy confinement were observed in many experiments. In HT-6M and HT-7 tokamaks, single and multi-pellet experiments are tried, and attractive results are obtained. (author)

  14. Pellet injection experiments on tokamaks in ASIPP, China

    International Nuclear Information System (INIS)

    Yang, Y.; Bao, Y.; Li, J.; Gu, X.; He, Y.

    1999-01-01

    Pellet Injection has been proven to be an effective method for deep fuelling of fusion devices. Improvements of both the particle confinement and the energy confinement were observed in many experiments. In HT-6M and HT-7 tokamaks, single and multi-pellet experiments are tried, and attractive results are obtained

  15. Electron beam injection during active experiments. I - Electromagnetic wave emissions

    Science.gov (United States)

    Winglee, R. M.; Kellogg, P. J.

    1990-01-01

    The wave emissions produced in Echo 7 experiment by active injections of electron beams were investigated to determine the properties of the electromagnetic and electrostatic fields for both the field-aligned and cross-field injection in such experiments and to evaluate the sources of free energy and relative efficiencies for the generation of the VLF and HF emissions. It is shown that, for typical beam energies in active experiments, electromagnetic effects do not substantially change the bulk properties of the beam, spacecraft charging, and plasma particle acceleration. Through simulations, beam-generated whistlers; fundamental z-mode and harmonic x-mode radiation; and electrostatic electron-cyclotron, upper-hybrid, Langmuir, and lower-hybrid waves were identified. The characteristics of the observed wave spectra were found to be sensitive to both the ratio of the electron plasma frequency to the cyclotron frequency and the angle of injection relative to the magnetic field.

  16. Flux-Level Transit Injection Experiments with NASA Pleiades Supercomputer

    Science.gov (United States)

    Li, Jie; Burke, Christopher J.; Catanzarite, Joseph; Seader, Shawn; Haas, Michael R.; Batalha, Natalie; Henze, Christopher; Christiansen, Jessie; Kepler Project, NASA Advanced Supercomputing Division

    2016-06-01

    Flux-Level Transit Injection (FLTI) experiments are executed with NASA's Pleiades supercomputer for the Kepler Mission. The latest release (9.3, January 2016) of the Kepler Science Operations Center Pipeline is used in the FLTI experiments. Their purpose is to validate the Analytic Completeness Model (ACM), which can be computed for all Kepler target stars, thereby enabling exoplanet occurrence rate studies. Pleiades, a facility of NASA's Advanced Supercomputing Division, is one of the world's most powerful supercomputers and represents NASA's state-of-the-art technology. We discuss the details of implementing the FLTI experiments on the Pleiades supercomputer. For example, taking into account that ~16 injections are generated by one core of the Pleiades processors in an hour, the “shallow” FLTI experiment, in which ~2000 injections are required per target star, can be done for 16% of all Kepler target stars in about 200 hours. Stripping down the transit search to bare bones, i.e. only searching adjacent high/low periods at high/low pulse durations, makes the computationally intensive FLTI experiments affordable. The design of the FLTI experiments and the analysis of the resulting data are presented in “Validating an Analytic Completeness Model for Kepler Target Stars Based on Flux-level Transit Injection Experiments” by Catanzarite et al. (#2494058).Kepler was selected as the 10th mission of the Discovery Program. Funding for the Kepler Mission has been provided by the NASA Science Mission Directorate.

  17. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  18. ECC2K-130 on NVIDIA GPUs

    NARCIS (Netherlands)

    Bernstein, D.J.; Chen, H.-C.; Cheng, C.M.; Lange, T.; Niederhagen, R.F.; Schwabe, P.; Yang, B.Y.

    2012-01-01

    [Updated version of paper at Indocrypt 2010] A major cryptanalytic computation is currently underway on multiple platforms, including standard CPUs, FPGAs, PlayStations and GPUs, to break the Certicom ECC2K-130 challenge. This challenge is to compute an elliptic-curve discrete logarithm on a Koblitz

  19. ECC2K-130 on NVIDIA GPUs

    NARCIS (Netherlands)

    Bernstein, D.J.; Chen, H.-C.; Cheng, C.M.; Lange, T.; Niederhagen, R.F.; Schwabe, P.; Yang, B.Y.; Gong, G.; Gupta, K.C.

    2010-01-01

    A major cryptanalytic computation is currently underway on multiple platforms, including standard CPUs, FPGAs, PlayStations and Graphics Processing Units (GPUs), to break the Certicom ECC2K-130 challenge. This challenge is to compute an elliptic-curve discrete logarithm on a Koblitz curve over $\\rm

  20. Experiments on Plume Spreading by Engineered Injection and Extraction

    Science.gov (United States)

    Mays, D. C.; Jones, M.; Tigera, R. G.; Neupauer, R.

    2014-12-01

    The notion that groundwater remediation is transport-limited emphasizes the coupling between physical (i.e., hydrodynamic), geochemical, and microbiological processes in the subsurface. Here we leverage this coupling to promote groundwater remediation using the approach of engineered injection and extraction. In this approach, inspired by the literature on chaotic advection, uncontaminated groundwater is injected and extracted through a manifold of wells surrounding the contaminated plume. The potential of this approach lies in its ability to actively manipulate the velocity field near the contaminated plume, generating plume spreading above and beyond that resulting from aquifer heterogeneity. Plume spreading, in turn, promotes mixing and reaction by chemical and biological processes. Simulations have predicted that engineered injection and extraction generates (1) chaotic advection whose characteristics depend on aquifer heterogeneity, and (2) faster rates and increased extent of groundwater remediation. This presentation focuses on a complimentary effort to experimentally demonstrate these predictions experimentally. In preparation for future work using refractive index matched (RIM) porous media, the experiments reported here use a Hele-Shaw apparatus containing silicone oil. Engineered injection and extraction is used to manipulate the geometry of an initially circular plume of black pigment, and photographs record the plume geometry after each step of injection of extraction. Image analysis, using complimentary Eulerian and Lagrangian approaches, reveals the thickness and variability of the dispersion zone surrounding the deformed plume of black pigment. The size, shape, and evolution of this dispersion zone provides insight into the interplay between engineered injection and extraction, which generates plume structure, and dispersion (here Taylor dispersion), which destroys plume structure. These experiments lay the groundwork for application of engineered

  1. Thermal shock studies associated with injection of emergency core coolant in pressurized water reactors

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Bolt, S.E.; Iskander, S.K.

    1977-01-01

    Studies to determine the accuracy of calculational techniques for predicting crack initiation and arrest in PWR vessels due to thermal shock from ECC injection are described. The reference calculational model is reviewed, the experimental program and facilities are described, and some thermal shock experiments and results are discussed

  2. Intercomparison of ozone measurements between Lidar and ECC-sondes

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, G.C. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Boesenberg, J. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Dier, H. [Meteorologisches Obs., Lindenberg (Germany); Goersdorf, U. [Meteorologisches Obs., Lindenberg (Germany); Matthias, V. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Peters, G. [Meteorologisches Obs., Lindenberg (Germany); Schaberl, T. [Hamburg Univ. (Germany). Meteorologisches Inst.; Senff, C. [Hamburg Univ. (Germany). Meteorologisches Inst.

    1996-02-01

    An intercomparison experiment for measurements of ozone vertical profiles in the lower troposphere was performed using a ground-based ozone DIAL (DIfferential Absorption Lidar) and ECC-sondes (Electrochemical Concentration Cell) attached to tethered as well as free flying balloons, which took place in June of 1994. The tethered balloon was used for ozone soundings in the planetary boundary layer up to an altitude of 500 m, while in the free troposphere free flying balloons were used. For the time series of up to 90 min obtained with the tethersondes both averages and standard deviations are compared. The mean difference for all measurements amounted to 3.5 {mu}g/m{sup 3} only, corresponding to 3.5%. For the instantaneous profiles compared to the free flying sondes the differences were only marginally larger, with a mean value of 3.6 {mu}g/m{sup 3} corresponding to 4.1%. With two exceptions all averages for a single profile stayed below 7 {mu}g/m{sup 3}. Larger individual excursions were observed. In some cases, in particular in regions of steep aerosol gradients at layer boundaries, most probably the lidar values cause the deviation, while in other cases the ECC-sonde is suspected to yield erroneous results. For the measured standard deviation those retrieved from DIAL measurements are generally larger than measured by the ECC-sondes, especially in regions of inhomogeneous aerosol distribution. For the measurements reported here, this is attributed to residual errors in the aerosol correction of the DIAL measurements. The general agreement found in this intercomparison is regarded as excellent, DIAL is proven to be a very valuable tool for detailed studies of the ozone distribution in the lower troposphere. (orig.)

  3. Multi-dimensional analysis of the ECC behavior in the UPI plant Kori Unit 1

    International Nuclear Information System (INIS)

    Bae, Sungwon; Chung, Bub-Dong; Bang, Young Seok

    2008-01-01

    A multi-dimensional transient analysis during the LBLOCA of the Kori Unit 1 has been performed by using the MARS code. Based on 1-D nodalization of the Kori Unit 1, the reactor vessel nodalizations have been replaced by the multi-dimensional component. The multi-dimensional component for the reactor vessel is designed as 5 radial, 8 peripheral, and 21 vertical grids. It is assumed that the fuel assemblies are homogeneously distributed in inner 3 radial grids. The outer 1 radial grid region is modeled as the core bypass. The outer-model 1 radial grid is used for the downcomer region. The corresponding heat structures and fuels are modified to fit for the multi-dimensional reactor vessel model. The form drag coefficients for the upper plenum and the core have been designated as 0.6 and 9.39, respectively. The form drag coefficients for the radial and peripheral directions are assigned to the same on the assumption of homogeneous distribution of the flow obstacles. After obtaining the 102% power steady operation condition, cold leg LOCA simulation is performed during 400 second period. The multi-dimensional steady run results show no severe differences compared to the traditional 1-D nodalization results. After the ECC injection starts, a liquid pool is maintained at the upper plenum because the ECCS water can not overcome the upward gas flow that comes from the reactor core through the upper tie plate. The depth of ECCS water pool is predicted as about 20% of the total height from the upper tie plate and the center line of the hot leg pipe. At the vicinity region of the active ECCS show higher depth of liquid pool. The accumulated water flow rate passing the upper tie plate is calculated by the transient result. Much downward water flow is obtained at the outer-most region of upper plenum space. The downward flow dominant region is about 32.3% of the total upper tie plate area. The accumulated ECCS bypass ratio is predicted as 27.64% at 300 second. It is calculated

  4. Wall conditioning experiments on TFTR using impurity pellet injection

    International Nuclear Information System (INIS)

    Strachan, J.D.; Mansfield, D.K.; Bell, M.G.; Collins, J.; Ernst, D.; Hill, K.; Hosea, J.; Timberlake, J.; Ulrickson, M.; Terry, J.; Marmar, E.; Snipes, J.

    1994-01-01

    This work describes experiments intended to optimize the limiter conditioning for TFTR supershots. It is shown that deposition of thin layers of lithium on the limiters by impurity pellet injection changes the plasma-wall interaction and improves supershot performance. Series of up to ten Ohmic plasmas each with two lithium pellets were useful in pre-conditioning the limiter. Generally, plasma performance increased with the amount of lithium deposited up to the maximal amount which could be deposited. Experiments were performed with different materials being deposited (carbon, boron and lithium) and with different methods of deposition. ((orig.))

  5. On the energy shift the ECC cusp. Does the shift really exist?

    International Nuclear Information System (INIS)

    Sarkadi, L.; Barrachina, R.O.

    2004-01-01

    The cusplike 'electron capture to the continuum' (ECC) peak appearing in the spectrum of the forward emitted electrons in ion-atom collisions are generally thought to be a divergence. Recently Shah et al., however, claimed that 'the ECC cusp is indeed a cusp, and not a divergence smoothed by the experiment'. These authors measured the ECC cusp for collisions of 10- and 20-keV protons with H 2 and He, and found that the peak was shifted to lower velocity than its expected position. We also carried out CTMC calculations (for the case of 20-keV protons on He) by which we demonstrated that the shift really exists but its value depends on the angular window of the electron detection. (K.A.)

  6. First neutral beam injection experiments on KSTAR tokamak.

    Science.gov (United States)

    Jeong, S H; Chang, D H; Kim, T S; In, S R; Lee, K W; Jin, J T; Chang, D S; Oh, B H; Bae, Y S; Kim, J S; Park, H T; Watanabe, K; Inoue, T; Kashiwagi, M; Dairaku, M; Tobari, H; Hanada, M

    2012-02-01

    The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1∕3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D(+):D(2)(+):D(3)(+) = 75:20:5 at beam current density of 85 mA/cm(2). The arc efficiency is more than 1.0 A∕kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the T(i) and T(e) profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

  7. First neutral beam injection experiments on KSTAR tokamaka)

    Science.gov (United States)

    Jeong, S. H.; Chang, D. H.; Kim, T. S.; In, S. R.; Lee, K. W.; Jin, J. T.; Chang, D. S.; Oh, B. H.; Bae, Y. S.; Kim, J. S.; Park, H. T.; Watanabe, K.; Inoue, T.; Kashiwagi, M.; Dairaku, M.; Tobari, H.; Hanada, M.

    2012-02-01

    The first neutral beam (NB) injection system of the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly, which is designed to deliver a 1.5 MW, NB power of deuterium at 95 keV. Before the beam injection experiments, discharge, and beam extraction characteristics of the ion source were investigated. The ion source has good beam optics in a broad range of beam perveance. The optimum perveance is 1.1-1.3 μP, and the minimum beam divergence angle measured by the Doppler shift spectroscopy is 0.8°. The ion species ratio is D+:D2+:D3+ = 75:20:5 at beam current density of 85 mA/cm2. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, a deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with a beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. The edge pedestal formation in the Ti and Te profiles was verified through CES and electron cyclotron emission diagnostics. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and plasma stored energy were found.

  8. Noise-based Stego-ECC

    Directory of Open Access Journals (Sweden)

    Rahardjo Budi

    2014-03-01

    Full Text Available A novel method of inserting noise into stream of ciphered text is proposed. The goal of inserting noise is to increase the level of uncertainty, thus making it harder for an attacker to detect data and noise. This form of steganography is implemented using Elliptic Curve Cryptography (ECC. The process of embedding the noise to the message in the encryption process and removing the noise from the message in the decryption process is proposed in this work by modifying ElGamal to allow auto detection of data and noise.

  9. Microfluidic model experiments on the injectability of monoclonal antibody solutions

    Science.gov (United States)

    Duchene, Charles; Filipe, Vasco; Nakach, Mostafa; Huille, Sylvain; Lindner, Anke

    2017-11-01

    Autoinjection devices that allow patients to self-administer medicine are becoming used more frequently; however, this advance comes with an increased need for precision in the injection process. The rare occurrence of protein aggregates in solutions of monoclonal antibodies constitutes a threat to the reliability of such devices. Here we study the flow of protein solutions containing aggregates in microfluidic model systems, mimicking injection devices, to gain fundamental understanding of the catastrophic clogging of constrictions of given size. We form aggregates by mechanically shaking or heating antibody solutions and then inject these solutions into microfluidic channels with varying types of constrictions. Geometrical clogging occurs when aggregates reach the size of the constriction and can in some cases be undone by increasing the applied pressure. We perform systematic experiments varying the relative aggregate size and the flow rate or applied pressure. The mechanical deformation of aggregates during their passage through constrictions is investigated to gain a better understanding of the clogging and unclogging mechanisms.

  10. Shear behavior of reinforced Engineered Cementitious Composites (ECC) beams

    DEFF Research Database (Denmark)

    Paegle, Ieva; Fischer, Gregor

    2010-01-01

    This paper describes an experimental investigation of the shear behavior of beams consisting of steel reinforced Engineered Cementitious Composites (ECC). Based on the strain hardening and multiple cracking behavior of ECC, this study investigates the extent to which ECC can improve the shear...... capacity of beams loaded primarily in shear and if ECC can partially or fully replace the conventional transverse steel reinforcement in beams. However, there is a lack of understanding of how the fibers affect the shear carrying capacity and deformation behavior of structural members if used either...

  11. Prediction of ROSA-III experiment

    International Nuclear Information System (INIS)

    Soda, Kunihisa

    1978-06-01

    ROSA-III experiment with the simulated BWR system is to investigate thermal hydraulic behavior as well as ECCS performance in a postulated loss-of-coolant accident. RUN 701 assumes average core power, high and low pressure core sprays and low pressure injection of ECCS. Prediction of experiment RUN 701 was made with computer code RELAP-4J. The results indicate the need for ROSA-III pump characteristics to be clarified and for liquid level formation model to be improved. Comparison of the prediction results with the experimental data should reveal the areas of modifications in calculation model. (auth.)

  12. Engineering of the divertor injection tokamak experiment (DITE)

    International Nuclear Information System (INIS)

    Plummer, K.M.; Bayes, D.V.; Bell, D.; Burt, J.; Galloway, F.; Sanders, B.C.; Skelton, D.E.; Varley, G.L.

    1976-01-01

    The DITE assembly has been constructed to study the effect of powerful neutral injection and the use of magnetic divertors in Tokamak systems. In addition, the plasma is stabilized by a position controlled feed-back vertical field system developed from results on the CLEO experiment, and added to DITE later in the design stage. The machine is designed for an ultimate plasma current of 340 kA, having a minor radius of 23 cm at q = 2, on a major radius of 113 cm. The 28 kG Bphi field, from 16 liquid nitrogen cooled coils has a 2% ripple at the edge of the plasma. The divertor is a ''bundle'' type, the present design of which is limited to operating in a Bphi field of 18 kG. Neutral Injection, initially by two, and ultimately by four injectors, is intended to supply about 1,500 kW of beam power. The engineering is now complete and the machine commissioned; this paper describes the up-to-date design of the machine and includes some of our experiences during design, construction and commissioning

  13. Status of experimental verification of ECCS efficiency

    International Nuclear Information System (INIS)

    Hein, D.; Watzinger, H.

    1978-01-01

    For the emergency cooling system of KWU pressurized water reactors with combined hot and cold leg injection an outline is given of the status of experiments designed to prove the efficiency of the emergency cooling system. This proof has been established by basic investigations which clarify the physical processes, by ''separate effects tests'' to derive and check correlations, and finally by investigations on the PKL test facility, in which a 1300 MWe pressurized water reactor including the primary circuts is simulated. These ''system effects tests'' are used to verify computer codes which are ultimately used to make predictions for the reactor. (author)

  14. A LOCA analysis for AHWR caused by ECCS header rupture

    International Nuclear Information System (INIS)

    Chatterjee, B.; Gawai, Amol; Gupta, S.K.; Kushwaha, H.S.

    2000-01-01

    Loss of coolant accident (LOCA) analyses for the proposed 750 MWth Advanced Heavy Water Reactor (AHWR), initiated by the rupture of 8 inch NB ECCS header has been carried out. This paper narrates the description of AHWR and associated ECCS, postulated scenario with which the analyses is carried out, results, discussion and conclusion

  15. Pellet injection in a tokamak hot plasma. Theory and experiment

    International Nuclear Information System (INIS)

    Picchiottino, J.M.

    1994-01-01

    The ultimate aim of pellet ablation studies is to predict what the plasma temperature and density profiles are just after a pellet injection. This requires description of the pellet ablation process, the parallel expansion of the ablatant and the fast outward motion of the deposited material since these three phenomena successively occur from the time of pellet injection to the moment when new axisymmetric profiles are reached. Only the two first points have been quantitatively modelled. If the most important processes of ablation physics are identified and although current models reproduce both measured penetrations and averaged characteristics of ablation clouds, some debatable points remain, mainly bearing on the drifts associated with the pellet motion and, consequently, on the effective shielding efficiency of the ionized part of the ablation cloud. During its parallel expansion, the ablated material experiences a strong poloidal rotation which depends on the ratio of the pellet and plasma masses and is due to the total kinetic momentum conservation on each magnetic surface. The fact that this rotation occurs on the same timescale as the outward motion suggests that both phenomena can be linked and that a comprehensive model of the whole fuelling process may emerge from considering the pellet and the plasma as a unique system. (author). 94 refs., 142 figs., 4 annexes

  16. ECCE Toolkit: Prototyping Sensor-Based Interaction

    Directory of Open Access Journals (Sweden)

    Andrea Bellucci

    2017-02-01

    Full Text Available Building and exploring physical user interfaces requires high technical skills and hours of specialized work. The behavior of multiple devices with heterogeneous input/output channels and connectivity has to be programmed in a context where not only the software interface matters, but also the hardware components are critical (e.g., sensors and actuators. Prototyping physical interaction is hindered by the challenges of: (1 programming interactions among physical sensors/actuators and digital interfaces; (2 implementing functionality for different platforms in different programming languages; and (3 building custom electronic-incorporated objects. We present ECCE (Entities, Components, Couplings and Ecosystems, a toolkit for non-programmers that copes with these issues by abstracting from low-level implementations, thus lowering the complexity of prototyping small-scale, sensor-based physical interfaces to support the design process. A user evaluation provides insights and use cases of the kind of applications that can be developed with the toolkit.

  17. Scaling and design report of ECC performance test facility (SWAT) of SMART

    International Nuclear Information System (INIS)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Shin Yong Chul; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae

    2010-12-01

    SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) was designed by 1/5 scaling ratio using the modified linear scaling method. The design characteristics of the SMART such that the elevation of RCP suction nozzles is the same with that of the ECC injection nozzles are maintained to reduce a distortion caused by the gravitational effect. Thermal hydraulic phenomena in a test facility designed by the modified linear scaling method can be simulated more accurately than those by the full-height and reduced area scaling method. The main part of the test section is SG-side upper down-comer. The boundary conditions are saturated steam and water flow condition and drain flow rate to control the collapsed water level in the down-comer. The test data of the SWAT can produce the well-defined boundary condition to validate the thermal hydraulic analysis code for the SMART

  18. Scaling and design report of ECC performance test facility (SWAT) of SMART

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Shin Yong Chul; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) was designed by 1/5 scaling ratio using the modified linear scaling method. The design characteristics of the SMART such that the elevation of RCP suction nozzles is the same with that of the ECC injection nozzles are maintained to reduce a distortion caused by the gravitational effect. Thermal hydraulic phenomena in a test facility designed by the modified linear scaling method can be simulated more accurately than those by the full-height and reduced area scaling method. The main part of the test section is SG-side upper down-comer. The boundary conditions are saturated steam and water flow condition and drain flow rate to control the collapsed water level in the down-comer. The test data of the SWAT can produce the well-defined boundary condition to validate the thermal hydraulic analysis code for the SMART

  19. Electron beam injection during active experiments. 1. Electromagnetic wave emissions

    International Nuclear Information System (INIS)

    Winglee, R.M.; Kellogg, P.J.

    1990-01-01

    During the active injection of an electron beam, a broad spectrum of waves is generated. In this paper examples of spectra from the recent Echo 7 experiment are presented. These results show that the characteristics of the emissions can change substantially with altitude. Two-dimensional (three velocity) relativistic electromagnetic particle simulations are used to investigate the changes in the plasma conditions required to account for the observed spectral variations. It is shown that many of these variations can be accounted for by assuming that the ratio of the electron plasma frequency ω pe to cyclotron frequency Ω e is less than unity at the lower altitudes of about 200 km and near or above unity at apogee of about 300 km. In the former case, whistlers with a cutoff at ω pe , lower hybrid and plasma waves are driven by the parallel beam energy while electromagnetic fundamental z mode and second harmonic x mode and electrostatic upper hybrid waves are driven by the perpendicular beam energy through the master instability. E x B drifts driven by perpendicular electric fields associated with the beam-plasma interaction can also be important in generating maser emission, particularly for field-aligned injection where there is no intrinsic perpendicular beam energy. The power in the electrostatic waves is a few percent of the beam energy and that in the electromagnetic waves a few tenths of a percent. In the latter case, where ω pe /Ω e increases above unity, emission in the fundamental z mode and second harmonic x mode become suppressed

  20. CO2 injection into fractured peridotites: a reactive percolation experiment

    Science.gov (United States)

    Escario, S.; Godard, M.; Gouze, P.; Leprovost, R.; Luquot, L.; Garcia-Rios, M.

    2017-12-01

    Mantle peridotites have the potential to trap CO2 as carbonates. This process observed in ophiolites and in oceanic environments provides a long term and safe storage for CO2. It occurs as a part of a complex suite of fluid-rock reactions involving silicate dissolution and precipitation of hydrous phases, carbonates and minor phases that may in turn modify the hydrodynamic properties and the reactivity of the reacted rocks. The efficiency and lastingness of the process require the renewal of fluids at the mineral-fluid interface. Fractures are dominant flow paths in exhumed mantle sections. This study aims at better understanding the effect of CO2-enriched saline fluids on hydrodynamic and chemical processes through fractured peridotites. Experiments were performed using the reactive percolation bench ICARE Lab 3 - Géosciences Montpellier. It allows monitoring the permeability changes during experiments. Effluents are recurrently sampled for analysing cation concentration, pH and alkalinity. Reacted rock samples were characterized by high resolution X-ray microtomography (ESRF ID19, Grenoble, France) and SEM. Experiments consisted in injecting CO2-enriched brines (NaCl 0.5 M) at a rate of 6 mL.h-1 into artificially fractured cores (9 mm diameter × 20 mm length) of Oman harzburgites at T=170°C and Ptotal = 25 MPa for up to 2 weeks. Fractures are of few µm apertures with rough walls. Three sets of experiments were performed at increasing value of [CO2] (0, 0.1 and 1 mol/kg). All experiments showed a decrease in permeability followed by steady state regime that can be caused by a decrease in the roughness of fracture walls (dissolution dominated process), thus favouring fracture closing, or by the precipitation of secondary phases. Maximum enrichments in Mg, Fe and Ca of the effluent fluids occur during the first 2 hours of the experiments whereas Si displays a maximum enrichment at t = 20 h, suggesting extensive dissolution. Maximum enrichments are observed with

  1. Overdose experiences among injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Wood Evan

    2010-05-01

    Full Text Available Abstract Background Although previous studies have identified high levels of drug-related harm in Thailand, little is known about illicit drug overdose experiences among Thai drug users. We sought to investigate non-fatal overdose experiences and responses to overdose among a community-recruited sample of injection drug users (IDU in Bangkok, Thailand. Methods Data for these analyses came from IDU participating in the Mit Sampan Community Research Project. The primary outcome of interest was a self-reported history of non-fatal overdose. We calculated the prevalence of past overdose and estimated its relationship with individual, drug-using, social, and structural factors using multivariate logistic regression. We also assessed the prevalence of ever witnessing an overdose and patterns of response to overdose. Results These analyses included 252 individuals; their median age was 36.5 years (IQR: 29.0 - 44.0 and 66 (26.2% were female. A history of non-fatal overdose was reported by 75 (29.8% participants. In a multivariate model, reporting a history of overdose was independently associated with a history of incarceration (Adjusted Odds Ratio [AOR] = 3.83, 95% Confidence Interval [CI]: 1.52 - 9.65, p = 0.004 and reporting use of drugs in combination (AOR = 2.48, 95% CI: 1.16 - 5.33, p = 0.019. A majority (67.9% reported a history of witnessing an overdose; most reported responding to the most recent overdose using first aid (79.5%. Conclusions Experiencing and witnessing an overdose were common in this sample of Thai IDU. These findings support the need for increased provision of evidence-based responses to overdose including peer-based overdose interventions.

  2. Experience with the new reverse injection scheme in the Tevatron

    International Nuclear Information System (INIS)

    Saritepe, S.; Goderre, G.; Annala, G.; Hanna, B.; Braun, A.

    1993-01-01

    In the new injection scenario the antiproton beam is injected onto a helical Tevatron orbit to avoid the detrimental effects of the beam-beam interaction at 150 GeV. The new scenario required changes in the tuning procedures. Antiprotons are too precious to be used for tuning, therefore the antiproton injection line has to be tuned with protons by reverse injecting them from the Tevatron into the Main Ring. Previously, the reverse injection was performed in one supercycle. One batch of uncoalesced bunches was injected into the Tevatron and ejected after 40 seconds. The orbit closure was performed in the Main Ring. In the new scheme the lambertson magnets have to be moved, separator polarities have to be switched, activities that cannot be completed in one supercycle. Therefore, the reverse injection sequence was changed. This involved the redefinition of TVBS (Tevatron Beam Synchronized Clock) event $D8 as MRBS (Main Ring Beam Synchronized Clock) $D8 thus making it possible to inject 6 proton batches (or coalesced bunches) and eject them one at a time on command, performing orbit closure each time in the Main Ring

  3. Neutral injection experiments on the ISX-B tokamak

    International Nuclear Information System (INIS)

    Scott, S.D.

    1983-01-01

    The following topics are described: (1) review of confinement scaling in ISX-B with strong neutral injection in clean plasmas, (2) discussion of observed energy confinement improvement in slightly contaminated discharges (factor less than or equal to 2), and (3) preliminary evaluation of confinement with balanced neutral beam injection

  4. Transverse Injection Experiment; Injection Transversale; Poslednie dostizheniya v oblasti inzhektirovaniya plazmy poperek magnitnogo polya; Inyeccion Transversal

    Energy Technology Data Exchange (ETDEWEB)

    Hammel, J. E.; Baker, D. A. [Los Alamos Scientific Laboratory, Los Alamos, NM (United States)

    1966-04-15

    The motion of a plasma stream injected transverse to a magnetic field has been discussed by several authors. In early experiments with the injection of a fast (50 to 70 cm/{mu}sec) dense (10{sup 14} ion/cm{sup 3}) plasma transverse to a magnetic field, a self polarization electric field was observed and the stream crossed the magnetic field with an E x B drift. The magnetic field was only slightly disturbed by the stream (| {Delta}B/B | <0.1) while the drift across magnetic fields up to 5 kG was at approximately the velocity of the injected stream. The height of the stream in the direction of V x B is compressed as it drifts into high magnetic field regions. At the same time, electron density measurements using interferometry techniques with the He-Ne laser show that the transverse field up to 7 kG causes no appreciable spreading of the stream to take place in the direction of B. Of interest is the action of the stream as it crosses a region where magnetic field lines reverse direction about a field null line. As the stream proceeds across the separatrix between the two field line directions, the electric field must change direction if the stream drift is to continue. The stream halts in the region of the separatrix while large currents are measured along magnetic field lines connecting the front of the stream with the following portions. Insulators placed to interrupt the current allow the stream to proceed into the reversed field region. By making use of the inductance associated with the depolarization current when magnetic field lines are tied at some distance to the side of the stream, a separation of fast and slow stream components can be made. The cutoff of the slow stream component is observed with the He-Ne laser interferometry techniques. Electric field measurements at several points along the stream show some of the more complicated features of the plasma flow. (author) [French] Le mouvement d'un faisceau de plasma injecte transversalement a un champ

  5. Particle balance studies in TEXTOR during experiments of pellet injection, helium injection, and ICR-heating

    International Nuclear Information System (INIS)

    Banno, T.; Finken, K.H.; Gray, D.S.; Winter, J.

    1995-01-01

    Analysis based on the particle conservation law has been carried out to observe the global fuelling process in tokamak discharges. The response of the net recycling flux from the first wall is investigated in the tokamak TEXTOR, using calibrated signals of the gas feed rate, the neutral gas pressure in the vessel, the total amount of electrons, and the particle removal rates by the ALT-II belt-pump limiter and by a main pump unit. Net absorption (pumping) of hydrogen by the wall is observed for almost all tokamak discharges since a new wall conditioning technique called siliconisation is employed. The net absorption or fuelling depending on the discharge condition influenced by injection of pellets, by helium gas injection combined with neutral beam injection, and by rf heating can be interpreted in terms of the particle-induced desorption effect with depth profile taken into consideration. ((orig.))

  6. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  7. Progestogen-only injectable contraceptive: Experience of women in ...

    African Journals Online (AJOL)

    Background: Progestogen-only injectable contraceptive is a long-acting contraceptive given intramuscularly to give protection against unwanted pregnancy for a period of 2 or 3 months, depending on the type. Alterations in menstrual pattern are a well known side effect of this effective contraceptive method. Objectives: To ...

  8. Assessment of human effective absorbed dose of 67 Ga-ECC based on biodistribution rat data.

    Science.gov (United States)

    Shanehsazzadeh, Saeed; Yousefnia, Hassan; Lahooti, Afsaneh; Zolghadri, Samaneh; Jalilian, Amir Reza; Afarideh, Hossien

    2015-02-01

    In a diagnostic context, determination of absorbed dose is required before the introduction of a new radiopharmaceutical to the market to obtain marketing authorization from the relevant agencies. In this work, the absorbed dose of [67 Ga]-ethylenecysteamine cysteine [(67 Ga)ECC] to human organs was determined by using distribution data for rats. For biodistribution data, the animals were sacrificed by CO2 asphyxiation at selected times after injection (0.5, 2 and 48 h, n = 3 for each time interval), then the tissue (blood, heart, lung, brain, intestine, feces, skin, stomach, kidneys, liver, muscle and bone) were removed. The absorbed dose was determined by Medical Internal Radiation Dose (MIRD) method after calculating cumulated activities in each organ. Our prediction shows that a 185-MBq injection of (67)Ga-ECC into the humans might result in an estimated absorbed dose of 0.029 mGy in the whole body. The highest absorbed doses are observed in the spleen and liver with 33.766 and 16.847 mGy, respectively. The results show that this radiopharmaceutical can be a good SPECT tracer since it can be produced easily and also the absorbed dose in each organ is less than permitted absorbed dose.

  9. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1978-05-01

    Of the total 10 ROSA-II/UHI performance tests, 6 were reported previously. The rest are presented and discussion is made on the effects of heat generation in the core and UHI injection and repeatability of experiments. In addition, the following are described: (1) Pressure spikes observed in the upper head after sudden stoppage of UHI injection, and (2) discharge flow oscillation possibly due to UHI water injection into the upper plenum. (auth.)

  10. Application of Engineered Cementitious Composites (ECC) in modular floor panels

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2008-01-01

    This paper describes the design, manufacturing, and structural behavior of a prefabricated floor panel consisting of a modular assembly of a thin-walled ECC slab and steel truss girders. The features of this composite structure include light weight, the modular manufacturing process...... concept introduced in this paper aims at improvements in the manufacturing process of the panels by casting the ECC slab separately and subsequently joining it with the steel trusses. The focus of this paper is on design and manufacturing of a prototype modular panel and on its structural behavior under...

  11. Pool scrubbing and hydrodynamic experiments on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.

    1995-01-01

    Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  12. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  13. Pool scrubbing and hydrodynamic experiment on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-01-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  14. Deportation experiences of women who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Robertson, Angela M; Lozada, Remedios; Vera, Alicia; Palinkas, Lawrence A; Burgos, José Luis; Magis-Rodriguez, Carlos; Rangel, Gudelia; Ojeda, Victoria D

    2012-04-01

    Deportation from the United States for drug offenses is common, yet the consequences of deportation for women drug users are poorly documented. In 2008, in Tijuana, Mexico, we conducted an exploratory qualitative study of migration, deportation, and drug abuse by interviewing 12 Mexican injection-drug-using women reporting U.S. deportation. Women reported heavy drug use before and after deportation, but greater financial instability and physical danger following deportation than when in the United States. We identified an unmet need for health and social services among deported drug-using women, including HIV prevention, drug treatment, physical and mental health services, and vocational training. Binational coordination is needed to help deported women resettle in Mexico.

  15. Modeling of ECC materials using numerical formulations based on plasticity

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  16. ECCS evaluation of B and W's 205-FA NSS

    International Nuclear Information System (INIS)

    Lowe, R.J.; Anderson, G.E. Jr.; Dunn, B.M.

    1975-06-01

    The effectiveness of the ECCS for B and W's 205-fuel assembly plants is evaluated and shown to meet all the requirements of 10 CFR 50.46. The results of various sensitivity studies, a spectrum of breaks, and an analysis to determine allowable linear heat rates under 10 CFR 50.46 are presented. (14 references) (U.S.)

  17. The JAERI code system for evaluation of BWR ECCS performance

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Akimoto, Masayuki; Asahi, Yoshiro; Abe, Kiyoharu; Muramatsu, Ken; Araya, Fumimasa; Sato, Kazuo

    1982-12-01

    Development of respective computer code system of BWR and PWR for evaluation of ECCS has been conducted since 1973 considering the differences of the reactor cooling system, core structure and ECCS. The first version of the BWR code system, of which developmental work started earlier than that of the PWR, has been completed. The BWR code system is designed to provide computational tools to analyze all phases of LOCAs and to evaluate the performance of the ECCS including an ''Evaluation Model (EM)'' feature in compliance with the requirements of the current Japanese Evaluation Guideline of ECCS. The BWR code system could be used for licensing purpose, i.e. for ECCS performance evaluation or audit calculations to cross-examine the methods and results of applicants or vendors. The BWR code system presented in this report comprises several computer codes, each of which analyzes a particular phase of a LOCA or a system blowdown depending on a range of LOCAs, i.e. large and small breaks in a variety of locations in the reactor system. The system includes ALARM-B1, HYDY-B1 and THYDE-B1 for analysis of the system blowdown for various break sizes, THYDE-B-REFLOOD for analysis of the reflood phase and SCORCH-B2 for the calculation of the fuel assembl hot plane temperature. When the multiple codes are used to analyze a broad range of LOCA as stated above, it is very important to evaluate the adequacy and consistency between the codes used to cover an entire break spectrum. The system consistency together with the system performance are discussed for a large commercial BWR. (author)

  18. Soil remediation by heat injection: Experiments and numerical modelling

    Energy Technology Data Exchange (ETDEWEB)

    Betz, C.; Emmert, M.; Faerber, A. [Univ. of Stuttgart (Germany)] [and others

    1995-03-01

    In order to understand physical processes of thermally enhanced soil vapor extraction methods in porous media the isothermal, multiphase formulation for the numerical model MUFTE will be extended by a non-isothermal, multiphase-multicomponent formulation. In order to verify the numerical model, comparison with analytical solutions for well defined problems will be carried out. To identify relevant processes and their interactions, the results of the simulation will be compared with well controlled experiments with sophisticated measurement equipment in three different scales. The aim is to compare the different numerical solution techniques namely Finite Element versus Integral Finite Difference technique as implemented in MUFTE and TOUGH2 [9] respectively.

  19. Injecting learning experience into geoethics for human and natural sustainability

    Science.gov (United States)

    Crookall, David

    2016-04-01

    Our early life experience has a strong influence on our actions in later life. Humans today are just starting to re-learn, collectively, how to treat Earth with the respect that it deserves and that is needed for our offspring to inherit a decent home. However, we still have a long way to go to instill in people at large the ethics, knowledge and skills necessary to ensure a healthy journey for humanity on spaceship. The experience of early upbringing, of schooling and of everyday life is probably the only path strong enough to develop in people a strong desire for ethical behaviour towards their environment. The problem is that the measures taken today to ensure the development of ethical behaviours in the population at large are woefully inadequate. At best, western school programmes contain a few lessons devoted to the environment, and even then they usually just pay lip service to the basics of the environment; they rarely aim to instill skills and knowledge in order to understand and care deeply for the environment. My presentation will suggest some practical ways to help communities build ethical frameworks and strategies to guide and generate tools, methods and activities that guide young people (pupils, students, scholars, researchers) to toward more ethical behaviours regarding their environment and their communities. Examples might include: - Developing geoethical dimensions of internships, in all areas; - Designing, testing and running simulation/games+debriefing providing a rich affective-cognitive context for grappling with geoethical problems- eg, FISH BANKS, KEEP COOL. - Pressuring governments to make geoethics, environmental care and climate change understanding central components of (almost) all educational programmes (in, eg, history, language, business, law, medicine, etc). - Subsidizing environmental-care summer schools for families and teachers at all levels. - Etc. One of my actions is founding a academic journal in the area, maybe with the

  20. Electron beam injection during active experiments. 2. Collisional effects

    International Nuclear Information System (INIS)

    Winglee, R.M.

    1990-01-01

    During active beam experiments the presence of high neutral densities at low altitudes and/or during thruster firings has been observed to modify the spacecraft charging and the properties of the beam. Two-dimensional (three velocity) electromagnetic particle simulations with ionizing collisions incorporated are used to investigate the modification of the beam-plasma interaction as the neutral density is increased. It is shown that when the spacecraft is uniformly immersed in a neutral cloud, most of the ionization is produced by direct ionization by the beam and its secondaries, rather than via vehicle-induced or wave-ineuced ionization for the neutral densities considered. This ionization enhances the return current into the spacecraft with the spacecraft potential being reduced well below the beam energy whent he collison period is shorter than the spacecraft charging time. Neutral densities of about 10 11 -10 12 cm -3 are required to produce this reduction in the spacecraft potential for typical ionospheric and beam parameters. At these densities, the beam is able to propagate away from the spacecraft with little distortion except in the case of thruster firings where the beam can be subject to large space-charge oscillations near the boundaries of the neutral cloud. The ionization of neutrals in the beam region also modifies the wave emissions and spatial profile of return currents into the spacecraft, both of which tend to become localized to the beam region in high neutral densities

  1. An overview of the BWR ECCS strainer blockage issues

    International Nuclear Information System (INIS)

    Serkiz, A.W.; Marshall, M.L. Jr.; Elliott, R.

    1996-01-01

    This Paper provides a brief overview of actions taken in the mid 1980s to resolve Unresolved Safety Issue (USI) A-43, open-quotes Containment Emergency Sump Performance,close quotes and their relationship to the BWR strainer blockage issue; the importance of insights gained from the Barseback-2 (a Swedish BWR) incident in 1992 and from ECCS strainer testing and inspections at the Perry nuclear power plant in 1992 and 1993; an analysis of an US BWR/4 with a Mark I containment; an international community sharing of knowledge relevant to ECCS strainer blockage, additional experimental programs; and identification of actions needed to resolve the strainer blockage issue and the status of such efforts

  2. Measurement and analysis of the ECC cusp structure

    Energy Technology Data Exchange (ETDEWEB)

    Pregliasco, R.G.; Garibotti, C.R.; Barrachina, R.O. (Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico Bariloche)

    1994-03-28

    We measured the electron capture to the continuum (ECC) peak in the ionization of He atoms by the collision of 50, 100 and 200 keV H[sup +] and 100 keV amu[sup -1]He[sup 2+]. We exhaustively scanned the double differential cross section between the angles -1.5[sup o] to 10[sup o] and within the velocities (1 [+-] 0.15)[upsilon][sub i] where [upsilon][sub i] is the impact velocity. We propose a new method for analysing the ECC structure which is independent of the spectrometer transmission function modellization and enables a direct comparison with the available theories. Furthermore, we distinguish two regimes for the ionization process, depending on whether the electron velocity is larger or smaller than the projectile velocity. (Author).

  3. The microstructure of self-healed PVA ECC under wet and dry cycles

    Directory of Open Access Journals (Sweden)

    Jia Huan Yu

    2010-06-01

    Full Text Available Self-healing of ECC (Engineered Cementitious Composites subjected to cyclic wetting and drying regimes is investigated in this paper. ECC structures subjected to outdoor environmental conditions such as wind and rain runoff can be simulated by accelerated test method of wetting and drying cycles. Uniaxial tensile tests of ECC M45 and ECC 2.8FA specimen are conducted respectively. It is found that crack width of ECC 2.8FA is around 10 μm with increased amount of fly ash, while the crack width of ECC M45 is around 100 μm. New insights about the microstructure and chemical composition analysis of ECC specimens initially cracked to 2% strain and then self-healed under wet-dry cycles are presented.

  4. On the energy shift of the ECC cusp. Does the shift really exist?

    International Nuclear Information System (INIS)

    Barrachina, R.O.; Sarkadi, L.

    2004-01-01

    Full text: The cusplike 'electron capture to the continuum' (ECC) peak appearing in the spectrum of the forward emitted electrons in ion-atom collisions is generally thought to be a divergence. The peak is centered at electron velocity that matches that of the projectile. Recently Illescas et al. [1] claimed, however, that 'the cusp is not a divergence smoothed by the experiment, and is slightly shifted from the impact-velocity value'. In a subsequent work Shah et al. [2] measured the ECC cusp for collisions of 10- and 20- keV protons with H2 and He, and found that the peak was indeed shifted to a velocity below its expected position. Their classical trajectory Monte Carlo (CTMC) calculations reproduced the observation well. In the present work we demonstrate by our CTMC calculations (made for the case of 20-keV protons on He) that the intensity, width and position of the ECC cusp do depend on the experimental conditions by which the electrons are detected (first of all, the acceptance angle of the electron spectrometer). We also present experimental data for this collision system. While the latter data are well reproduced by our CTMC calculations, neither the theoretical results, nor the experimental data of the present work support of the findings of Shah et al. [2]. At the same time, analyzing the problem in the framework of the general final-state interaction theory of cusp formation [3], we concluded that 'rigorously' speaking Shah et al. [2] are right when they state that the ECC cusp is not a divergence. The divergence is smeared out by the scattering of the projectile. However, this effect is negligibly small at the lowest energy that was considered in their paper, 10 keV. At this impact energy the projectile motion is smeared within an angular region Δθ th ∼ 0.06 deg, which is much smaller than the acceptance angle of the experiment, Δθ exp ∼ 1.5 deg

  5. Fate of herbicides in a shallow aerobic aquifer: A continuous field injection experiment (Vejen,Denmark)

    DEFF Research Database (Denmark)

    Broholm, Mette; Rügge, K.; Tuxen, Nina

    2001-01-01

    A continuous, natural gradient, field injection experiment, involving six herbicides and a tracer, was performed in a shallow aerobic aquifer near Vejen, Denmark. Bentazone, ()-2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP), dichlorprop, isoproturon, and the dichlobenil metabolite 2,6-dichlor...... in groundwater potentials. An average flow velocity of 0.5 m/d was observed, as depicted by bromide. Bentazone, BAM, MCPP, and dichlorprop retardation was negligible, and only slight retardation of isoproturon was observed in the continuous injection experiment and a preceding pulse experiment. No degradation...... of bentazone was observed in the aerobic aquifer during the monitoring period. BAM and isoproturon were not degraded within 5 m downgradient of the injection. The two phenoxy acids MCPP and dichlorprop were both degraded in the aerobic aquifer. Near the source a lag phase was observed followed by fast...

  6. Results and analysis of the TMX electron-beam injection experiments

    International Nuclear Information System (INIS)

    Poulsen, P.; Grubb, D.P.

    1980-01-01

    Electron beams (e-beams) were injected into the Tandem Mirror Experiment (TMX) plasma in order to investigate the effect on the ion cyclotron fluctuations of the plasma. The power level of the e-beams was comparable to that of the injected neutral beams. It was found that injection of the e-beams produced no significant effect on the ion cyclotron fluctuations, the measured plasma parameters, or the particle and power flow of the plasma. The increase in bulk electron temperature and the production of mirror-confined electrons found in previous experiments in which e-beams were injected into a mirror-confined plasma were not observed in this experiment. Analysis of the regions and frequencies of wave creation and absorption within the plasma shows that the plasma density and magnetic field profiles through the plasma strongly affect the resonances encountered by the waves. The steep axial density profiles produced by neutral-beam injection in the TMX experiment are not conducive to efficient coupling of the e-beam energy to the plasma

  7. Designing Fault-Injection Experiments for the Reliability of Embedded Systems

    Science.gov (United States)

    White, Allan L.

    2012-01-01

    This paper considers the long-standing problem of conducting fault-injections experiments to establish the ultra-reliability of embedded systems. There have been extensive efforts in fault injection, and this paper offers a partial summary of the efforts, but these previous efforts have focused on realism and efficiency. Fault injections have been used to examine diagnostics and to test algorithms, but the literature does not contain any framework that says how to conduct fault-injection experiments to establish ultra-reliability. A solution to this problem integrates field-data, arguments-from-design, and fault-injection into a seamless whole. The solution in this paper is to derive a model reduction theorem for a class of semi-Markov models suitable for describing ultra-reliable embedded systems. The derivation shows that a tight upper bound on the probability of system failure can be obtained using only the means of system-recovery times, thus reducing the experimental effort to estimating a reasonable number of easily-observed parameters. The paper includes an example of a system subject to both permanent and transient faults. There is a discussion of integrating fault-injection with field-data and arguments-from-design.

  8. Registration of ELF waves in rocket-satellite experiment with plasma injection

    Science.gov (United States)

    Korobeinikov, V. G.; Oraevskii, V. N.; Ruzhin, Iu. Ia.; Sobolev, Ia. P.; Skomarovskii, V. S.; Chmyrev, V. M.; Namazov, C. A.; Pokhunkov, A. A.; Nesmeianov, V. I.

    1992-12-01

    Two rocket KOMBI-SAMA experiments with plasma injection at height 100-240 km were performed in August 1987 in the region of Brazilian magnetic anomaly (L = 1.25). The launching time of the rocket was determined so that plasma injection was at the time when COSMOS 1809 satellite passed as close as possible to magnetic tube of injection. Caesium plasma jet was produced during not less than 300 s by an electric plasma generator separated from the payload. When the satellite passed the geomagnetic tube intersecting the injection region an enhancement of ELF emission at 140 Hz, 450 Hz by a factor of 2 was registered on board the satellite. An enhancement of energetic particle flux by a factor of 4-5 was registered on board the rocket. Observed ELF emission below 100 Hz is interpreted as the generation of oblique electromagnetic ion-cyclotron waves due to drift plasma instability at the front of the plasma jet.

  9. In situ water and gas injection experiments performed in the Hades Underground Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Volckaert, G.; Ortiz, L.; Put, M. [SCK-CEN, Mol (Belgium). Geological Waste Disposal Unit

    1995-12-31

    The movement of water and gas through plastic clay is an important subject in the research at SCK-CEN on the possible disposal of high level radioactive waste in the Boom clay layer at Mol. Since the construction of the Hades underground research facility in 1983, SCK-CEN has developed and installed numerous piezometers for the geohydrologic characterization and for in situ radionuclide migration experiments. In situ gas and water injection experiments have been performed at two different locations in the underground laboratory. The first location is a multi filter piezometer installed vertically at the bottom of the shaft in 1986. The second location is a three dimensional configuration of four horizontal multi piezometers installed from the gallery. This piezometer configuration was designed for the MEGAS (Modelling and Experiments on GAS migration through argillaceous rocks) project and installed in 1992. It contains 29 filters at distances between 10 m and 15 m from the gallery in the clay. Gas injection experiments show that gas breakthrough occurs at a gas overpressure of about 0.6 MPa. The breakthrough occurs by the creation of gas pathways along the direction of lowest resistance i.e. the zone of low effective stress resulting from the drilling of the borehole. The water injections performed in a filter -- not used for gas injection -- show that the flow of water is also influenced by the mechanical stress conditions. Low effective stress leads to higher hydraulic conductivity. However, water overpressures up to 1.3 MPa did not cause hydrofracturing. Water injections performed in a filter previously used for gas injections, show that the occluded gas hinders the water flow and reduces the hydraulic conductivity by a factor two.

  10. Three-dimensional modelling of an injection experiment in the anaerobic part of a landfill plume

    DEFF Research Database (Denmark)

    Juul Petersen, Michael; Engesgaard, Peter Knudegaard; Bjerg, Poul Løgstrup

    1998-01-01

    Analytical and numerical three-dimensional (3-D) simulations have been conducted and compared to data obtained from a large-scale (50 m), natural gradient field injection experiment. Eighteen different xenobiotic compounds (i.e. benzene, toluene, o-xylene, naphthalene, 1,1,1-TCA, PCE, and TCE...

  11. Sequential-Injection Analysis: Principles, Instrument Construction, and Demonstration by a Simple Experiment

    Science.gov (United States)

    Economou, A.; Tzanavaras, P. D.; Themelis, D. G.

    2005-01-01

    The sequential-injection analysis (SIA) is an approach to sample handling that enables the automation of manual wet-chemistry procedures in a rapid, precise and efficient manner. The experiments using SIA fits well in the course of Instrumental Chemical Analysis and especially in the section of Automatic Methods of analysis provided by chemistry…

  12. Repetitive laser fusion experiment and operation using a target injection system

    International Nuclear Information System (INIS)

    Nishimura, Yasuhiko; Komeda, Osamu; Mori, Yoshitaka

    2017-01-01

    Since 2008, a collaborative research project on laser fusion development based on a high-speed ignition method using repetitive laser has been carried out with several collaborative research institutes. This paper reports the current state of operation of high repetition laser fusion experiments, such as target introduction and control based on a target injection system that allows free falling under 1 Hz, using a high repetition laser driver that has been under research and development, as well as the measurement of targets that freely fall. The HAMA laser driver that enabled high repetition fusion experiments is a titanium sapphire laser using a diode-pumped solid-state laser KURE-I of green light output as a driver pump light source. In order to carry out high repetition laser fusion experiments, the target injection device allows free falling of deuterated polystyrene solid sphere targets of 1 mm in diameter under 1 Hz. The authors integrated the developed laser and injection system, and succeeded first in the world in making the nuclear fusion reaction continuously by hitting the target to be injected with laser, which is essential technology for future laser nuclear fusion reactor. In order to realize repetition laser fusion experiments, stable laser, target synchronization control, and target position measurement technologies are indispensable. (A.O.)

  13. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    International Nuclear Information System (INIS)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S.

    2015-01-01

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  14. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S., E-mail: yhwang@snu.ac.kr

    2015-10-15

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  15. Neutral Beam Injection Requirements and Design Issues for the National Compact Stellarator Experiment; TOPICAL

    International Nuclear Information System (INIS)

    H.W. Kugel; H. Neilson; W. Reiersen; M. Zarnstorff

    2002-01-01

    The National Compact Stellarator Experiment (NCSX) will require 6 MW of 50 keV neutral beam injection (NBI) with initial pulse lengths of 500 msec and upgradeable to pulse lengths of 1.5 sec. This paper discusses the NCSX NBI requirements and design issues, and shows how these are provided by the candidate PBX-M[Princeton Beta Experiment-Modification] NBI system

  16. Neutral Beam Injection Requirements and Design Issues for the National Compact Stellarator Experiment

    International Nuclear Information System (INIS)

    Kugel, H.W.; Neilson, H.; Reiersen, W.; Zarnstorff, M.

    2002-01-01

    The National Compact Stellarator Experiment (NCSX) will require 6 MW of 50 keV neutral beam injection (NBI) with initial pulse lengths of 500 msec and upgradeable to pulse lengths of 1.5 sec. This paper discusses the NCSX NBI requirements and design issues, and shows how these are provided by the candidate PBX-M [Princeton Beta Experiment-Modification] NBI system

  17. Early results of microwave transmission experiments through an overly dense rectangular plasma sheet with microparticle injection

    Energy Technology Data Exchange (ETDEWEB)

    Gillman, Eric D., E-mail: eric.gillman.ctr@nrl.navy.mil [National Research Council Postdoctoral Associate at the U.S. Naval Research Laboratory, Washington, DC 20375 (United States); Amatucci, W. E. [U.S. Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-06-15

    These experiments utilize a linear hollow cathode to create a dense, rectangular plasma sheet to simulate the plasma layer surrounding vehicles traveling at hypersonic velocities within the Earth's atmosphere. Injection of fine dielectric microparticles significantly reduces the electron density and therefore lowers the electron plasma frequency by binding a significant portion of the bulk free electrons to the relatively massive microparticles. Measurements show that microwave transmission through this previously overly dense, impenetrable plasma layer increases with the injection of alumina microparticles approximately 60 μm in diameter. This method of electron depletion is a potential means of mitigating the radio communications blackout experienced by hypersonic vehicles.

  18. Using ECC DRAM to Adaptively Increase Memory Capacity

    OpenAIRE

    Luo, Yixin; Ghose, Saugata; Li, Tianshi; Govindan, Sriram; Sharma, Bikash; Kelly, Bryan; Boroumand, Amirali; Mutlu, Onur

    2017-01-01

    Modern DRAM modules are often equipped with hardware error correction capabilities, especially for DRAM deployed in large-scale data centers, as process technology scaling has increased the susceptibility of these devices to errors. To provide fast error detection and correction, error-correcting codes (ECC) are placed on an additional DRAM chip in a DRAM module. This additional chip expands the raw capacity of a DRAM module by 12.5%, but the applications are unable to use any of this extra c...

  19. Analysis of Cavity Pressure and Warpage of Polyoxymethylene Thin Walled Injection Molded Parts: Experiments and Simulations

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2014-01-01

    Process analysis and simulations on molding experiments of 3D thin shell parts have been conducted. Moldings were carried out with polyoxymethylene (POM). The moldings were performed with cavity pressure sensors in order to compare experimental process results with simulations. The warpage...... was characterized by measuring distances using a tactile coordinate measuring machine (CMM). Molding simulations have been executed taking into account actual processing conditions. Various aspects have been considered in the simulation: machine barrel geometry, injection speed profiles, cavity injection pressure......, melt and mold temperatures, material rheological and pvT characterization. Factors investigated for comparisons were: injection pressure profile, short shots length, flow pattern, and warpage. A reliable molding experimental database was obtained, accurate simulations were conducted and a number...

  20. Operational experience of the upgraded LHC injection kicker magnets during Run 2 and future plans

    Science.gov (United States)

    Barnes, M. J.; Adraktas, A.; Bregliozzi, G.; Goddard, B.; Ducimetière, L.; Salvant, B.; Sestak, J.; Vega Cid, L.; Weterings, W.; Vallgren, C. Yin

    2017-07-01

    During Run 1 of the LHC, one of the injection kicker magnets caused occasional operational delays due to beam induced heating with high bunch intensity and short bunch lengths. In addition, there were also sporadic issues with vacuum activity and electrical flashover of the injection kickers. An extensive program of studies was launched and significant upgrades were carried out during Long Shutdown 1 (LS 1). These upgrades included a new design of beam screen to reduce both beam coupling impedance of the kicker magnet and the electric field associated with the screen conductors, hence decreasing the probability of electrical breakdown in this region. This paper presents operational experience of the injection kicker magnets during the first years of Run 2 of the LHC, including a discussion of faults and kicker magnet issues that limited LHC operation. In addition, in light of these issues, plans for further upgrades are briefly discussed.

  1. Air-water mixing experiments for direct vessel injection of KNGR

    International Nuclear Information System (INIS)

    Hwang, Do Hyun

    2000-02-01

    Two air-water mixing experiments are conducted to understand the flow behavior in the downcomer for Direct Vessel Injection (DVI) of Korean Next Generation Reactor (KNGR). In the first experiment which is an air-water experiment in the rectangular channel with the gap size of 1cm, the width of water film is proportional to the water and air velocities and the inclined angle is proportional to the water velocity only, regardless of the water velocity injected in the rectangular channel. It is observed that the amount of entrained water is negligible. In the second experiment which is a full-scaled water jetting experiment without air flow, the width of water film is proportional to the flow rate injected from the pipe exit and the film thickness of water varies from 1.0mm to 5.0mm, and the maximum thickness does not exceed 5.0mm. The amount of water separated from the liquid film after striking of water jetting on the wall is measured. The amount of separation water is proportional to the flow rate, but the separation ratio in the full-scaled water jetting is not over 15%. A simplified physical model, which is designed to predict the trajectories of the width of water film, is validated through the comparison with experiment results. The 13 .deg. upward water droplet of the water injected from the pipe constitutes the outermost boundary at 1.7m below from pipe level, after the water impinges against the wall. In the model, the parameter, η which represents the relationship between the jetting velocity and the initial spreading velocity, is inversely proportional to the water velocity when it impinges against the wall. The error of the predictions by the model is decreased within 14% to the experimental data through use of exponential fitting of η for the jetting water velocity

  2. High performance experiments on high pressure supersonic molecular beam injection in the HL-1M tokamak

    International Nuclear Information System (INIS)

    Yao Lianghua; Dong Jiafu; Zhou Yan; Feng Beibing; Cao Jianyong; Li Wei; Feng Zhen; Zhang Jiquan; Hong Wenyu; Cui Zhengying; Wang Enyao; Liu Yong

    2004-01-01

    Supersonic molecular beam injection (SMBI) was first proposed and demonstrated on the HL-1 tokamak and was successfully developed and used on HL-1M. Recently, new results of SMBI experiments were obtained by increasing the gas pressure from 0.5 to over 1.0 MPa. A stair-shaped density increment was obtained with high-pressure multi-pulse SMBI that was similar to the density evolution behaviour during multi-pellet injection. This demonstrated the effectiveness of SMBI as a promising fuelling tool for steady-state operation. The penetration depth and injection speed of the high-pressure SMBI were roughly measured from the contour plot of the Hα emission intensity. It was shown that injected particles could penetrate into the core region of the plasma. The penetration speed of high-pressure SMBI particles in the plasma was estimated to be about 1200 m s -1 . In addition, clusters within the beam may play an important role in the deeper injection. (author)

  3. Local Helicity Injection Systems for Non-solenoidal Startup in the PEGASUS Toroidal Experiment

    Science.gov (United States)

    Perry, J. M.; Barr, J. L.; Bongard, M. W.; Fonck, R. J.; Hinson, E. T.; Lewicki, B. T.; Redd, A. J.

    2013-10-01

    Local helicity injection is being developed in the PEGASUS Toroidal Experiment for non-solenoidal startup in spherical tokamaks. The effective loop voltage due to helicity injection scales with the area of the injectors, requiring the development of electron current injectors with areas much larger than the 2 cm2 plasma arc injectors used to date. Solid and gas-effused metallic electrodes were found to be unusable due to reduced injector area utilization from localized cathode spots and narrow operational regimes. An integrated array of 8 compact plasma arc sources is thus being developed for high current startup. It employs two monolithic power systems, for the plasma arc sources and the bias current extraction system. The array effectively eliminates impurity fueling from plasma-material interaction by incorporating a local scraper-limiter and conical-frustum bias electrodes to mitigate the effects of cathode spots. An energy balance model of helicity injection indicates that the resulting 20 cm2 of total injection area should provide sufficient current drive to reach 0.3 MA. At that level, helicity injection drive exceeds that from poloidal induction, which is the relevant operational regime for large-scale spherical tokamaks. Future placement of the injector array near an expanded boundary divertor region will test simultaneous optimization of helicity drive and the Taylor relaxation current limit. Work supported by US DOE Grant DE-FG02-96ER54375.

  4. The first experiment of MPD Jet injection into GAMMA 10 plasma

    International Nuclear Information System (INIS)

    Ichimura, Kazuya; Nakashima, Yousuke; Takeda, Hisato

    2014-01-01

    Results of the first experiment of short pulse plasma injection by MPD (magneto plasma dynamic) Jet into GAMMA 10/PDX's longer pulse plasma are reported. In the experiment, a new method for plasma start-up without using plasma guns was applied. In this method, the main plasma of GAMMA 10/PDX was produced by ECRH (electron cyclotron resonance heating) and ICRF (ion cyclotron range of frequency). Then, MPD Jet plasma was injected into the main plasma along magnetic field line. As a result, density of the main plasma was increased and the end-loss flux was doubled. Flow velocity of the plasmoid injected by the MPD Jet was evaluated from the change of plasma density in each cell of the tandem mirror. The result indicated that the flow speed is several km/s. It is found that the plasmoid worked as strong fueling device which dramatically raises the density of plasma. Therefore injection of MPD Jet plasma into tandem mirror can be a useful tool to study physical phenomena of divertor and PWI. (author)

  5. Disease Management of Early Childhood Caries: ECC Collaborative Project.

    Science.gov (United States)

    Ng, Man Wai; Ramos-Gomez, Francisco; Lieberman, Martin; Lee, Jessica Y; Scoville, Richard; Hannon, Cindy; Maramaldi, Peter

    2014-01-01

    Until recently, the standard of care for early childhood caries (ECC) has been primarily surgical and restorative treatment with little emphasis on preventing and managing the disease itself. It is now recognized that surgical treatment alone does not address the underlying etiology of the disease. Despite costly surgeries and reparative treatment, the onset and progression of caries are likely to continue. A successful rebalance of risk and protective factors may prevent, slow down, or even arrest dental caries and its progression. An 18-month risk-based chronic disease management (DM) approach to address ECC in preschool children was implemented as a quality improvement (QI) collaborative by seven teams of oral health care providers across the United States. In the aggregate, fewer DM children experienced new cavitation, pain, and referrals to the operating room (OR) for restorative treatment compared to baseline historical controls. The teams found that QI methods facilitated adoption of the DM approach and resulted in improved care to patients and better outcomes overall. Despite these successes, the wide scale adoption and spread of the DM approach may be limited unless health policy and payment reforms are enacted to compensate providers for implementing DM protocols in their practice.

  6. Development of CANDU ECCS performance evaluation methodology and guides

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Kwang Hyun; Park, Kyung Soo; Chu, Won Ho [Korea Maritime Univ., Jinhae (Korea, Republic of)

    2003-03-15

    The objectives of the present work are to carry out technical evaluation and review of CANDU safety analysis methods in order to assist development of performance evaluation methods and review guides for CANDU ECCS. The applicability of PWR ECCS analysis models are examined and it suggests that unique data or models for CANDU are required for the following phenomena: break characteristics and flow, frictional pressure drop, post-CHF heat transfer correlations, core flow distribution during blowdown, containment pressure, and reflux rate. For safety analysis of CANDU, conservative analysis or best estimate analysis can be used. The main advantage of BE analysis is a more realistic prediction of margins to acceptance criteria. The expectation is that margins demonstrated with BE methods would be larger that when a conservative approach is applied. Some outstanding safety analysis issues can be resolved by demonstration that accident consequences are more benign than previously predicted. Success criteria for analysis and review of Large LOCA can be developed by top-down approach. The highest-level success criteria can be extracted from C-6 and from them, the lower level criteria can be developed step-by-step, in a logical fashion. The overall objectives for analysis and review are to verify radiological consequences and frequency are met.

  7. Disease Management of Early Childhood Caries: ECC Collaborative Project

    Directory of Open Access Journals (Sweden)

    Man Wai Ng

    2014-01-01

    Full Text Available Until recently, the standard of care for early childhood caries (ECC has been primarily surgical and restorative treatment with little emphasis on preventing and managing the disease itself. It is now recognized that surgical treatment alone does not address the underlying etiology of the disease. Despite costly surgeries and reparative treatment, the onset and progression of caries are likely to continue. A successful rebalance of risk and protective factors may prevent, slow down, or even arrest dental caries and its progression. An 18-month risk-based chronic disease management (DM approach to address ECC in preschool children was implemented as a quality improvement (QI collaborative by seven teams of oral health care providers across the United States. In the aggregate, fewer DM children experienced new cavitation, pain, and referrals to the operating room (OR for restorative treatment compared to baseline historical controls. The teams found that QI methods facilitated adoption of the DM approach and resulted in improved care to patients and better outcomes overall. Despite these successes, the wide scale adoption and spread of the DM approach may be limited unless health policy and payment reforms are enacted to compensate providers for implementing DM protocols in their practice.

  8. Breakdown pressures and characteristic flaw sizes during fluid injection experiments in shale at elevated confining pressures.

    Science.gov (United States)

    Chandler, M.; Mecklenburgh, J.; Rutter, E. H.; Taylor, R.; Fauchille, A. L.; Ma, L.; Lee, P. D.

    2017-12-01

    Fracture propagation trajectories in gas-bearing shales depend on the interaction between the anisotropic mechanical properties of the shale and the anisotropic in-situ stress field. However, there is a general paucity of available experimental data on their anisotropic mechanical, physical and fluid-flow properties, especially at elevated confining pressures. A suite of mechanical, flow and elastic measurements have been made on two shale materials, the Whitby mudrock and the Mancos shale (an interbedded silt and mudstone), as well as Pennant sandstone, an isotropic baseline and tight-gas sandstone analogue. Mechanical characterization includes standard triaxial experiments, pressure-dependent permeability, brazilian disk tensile strength, and fracture toughness determined using double-torsion experiments. Elastic characterisation was performed through ultrasonic velocities determined using a cross-correlation method. Additionally, we report the results of laboratory-scale fluid injection experiments for the same materials. Injection experiments involved the pressurisation of a blind-ending central hole in a dry cylindrical sample. Pressurisation is conducted under constant volume-rate control, using silicon oils of varying viscosities. Breakdown pressure is not seen to exhibit a strong dependence on rock type or orientation, and increases linearly with confining pressure. In most experiments, a small drop in the injection pressure record is observed at what is taken to be fracture initiation, and in the Pennant sandstone this is accompanied by a small burst of acoustic energy. The shale materials were acoustically quiet. Breakdown is found to be rapid and uncontrollable after initiation if injection is continued. A simplified 2-dimensional model for explaining this is presented in terms of the stress intensities at the tip of a pressurised crack, and is used alongside the triaxial data to derive a characteristic flaw size from which the fractures have initiated

  9. Safety design/analysis and scenario for prevention of CDA with ECCS in lead-bismuth-cooled fast reactor

    International Nuclear Information System (INIS)

    Minoru, Takahashi; Vaclav, Dostal; Abu Khalid, Rivai; Novitrian; Yumi, Yamada

    2007-01-01

    Safety design has been developed to show safety feature of Pb-Bi-cooled direct contact boiling water small fast reactor (PBWFR). The core is designed to have negative void reactivity even if the entire core and upper plenum are voided by steam intrusion from above. In-vessel type control rod driving mechanisms are used to prevent control rods from accidental ejection due to high pressure in the reactor vessel. In cases of coolant leakage from reactor vessel and feed water pipes, Pb-Bi coolant level in the reactor vessel is kept at the required level for decay heat removal by means of closed type guard vessel. Dual pipes are adopted to avoid leak of water in the feedwater system. Pump trip in feedwater systems initiates loss of coolant flow (LOF) event, although there is no concern of loss of flow accident due to primary pump trip. Injection of high pressure water slows down the flow-coast-down of feedwater at the LOF event. It has been evaluated that the fuel temperature is kept lower than safety limits at the unprotected loss of flow and heat sink (ATWS). A scenario for prevention of the core disruptive accident (CDA) with the emergency core cooling system (ECCS) is examined. The reactor becomes super-critical when the reactor vessel is filled with water. It is necessary to use water with boric acid for the ECC system, and additional backup rods for sub-critical core in water injection. (authors)

  10. Gravity driven emergency core cooling experiments with the PACTEL facility

    International Nuclear Information System (INIS)

    Munther, R.; Kalli, H.; Kouhia, J.

    1996-01-01

    PACTEL (Parallel Channel Test Loop) is an experimental out-of-pile facility designed to simulated the major components and system behaviour of a commercial Pressurized Water Reactor (PWR) during different postulated LOCAs and transients. The reference reactor to the PACTEL facility is Loviisa type WWER-440. The recently made modifications enable experiments to be conducted also on the passive core cooling. In these experiments the passive core cooling system consisted of one core makeup tank (CMT) and pressure balancing lines from the pressurizer and from a cold leg connected to the top of the CMT in order to maintain the tank in pressure equilibrium with the primary system during ECC injection. The line from the pressurizer to the core makeup tank was normally open. The ECC flow was provided from the CMT located at a higher elevation than the main part of the primary system. A total number of nine experiments have been performed by now. 4 refs, 7 figs, 3 tabs

  11. Gravity driven emergency core cooling experiments with the PACTEL facility

    Energy Technology Data Exchange (ETDEWEB)

    Munther, R; Kalli, H [University of Technology, Lappeenranta (Finland); Kouhia, J [Technical Research Centre of Finland, Lappeenranta (Finland)

    1996-12-01

    PACTEL (Parallel Channel Test Loop) is an experimental out-of-pile facility designed to simulated the major components and system behaviour of a commercial Pressurized Water Reactor (PWR) during different postulated LOCAs and transients. The reference reactor to the PACTEL facility is Loviisa type WWER-440. The recently made modifications enable experiments to be conducted also on the passive core cooling. In these experiments the passive core cooling system consisted of one core makeup tank (CMT) and pressure balancing lines from the pressurizer and from a cold leg connected to the top of the CMT in order to maintain the tank in pressure equilibrium with the primary system during ECC injection. The line from the pressurizer to the core makeup tank was normally open. The ECC flow was provided from the CMT located at a higher elevation than the main part of the primary system. A total number of nine experiments have been performed by now. 4 refs, 7 figs, 3 tabs.

  12. The data analysis of the single well injection-withdraw tracer experiment using the MACRO II

    International Nuclear Information System (INIS)

    Shirakawa, Toshihiko; Kanazawa, Yasuo; Hatanaka, Koichiro

    2001-04-01

    On understanding the radionuclide transport in natural barrier in radioactive waste isolation research, the macroscopic dispersion in heterogeneous permeability field in the underground rock is regarded as an important process. Therefore, we have conducted lots of tracer experiments by the MACRO II facility with an artificially constructed heterogeneous permeability field. In order to study the scale dependence of dispersion coefficients in case of laboratory experiments, we placed the flow cell horizontally, and conducted injection-withdraw tracer experiment with a single well. We have conducted 15 cases experiments. These cases were prepared by changing a position of single well and the injection-withdraw time. At each position we have conducted 9 cases and 6 cases experiments. In this report, we evaluated the macroscopic dispersion coefficients by the fitting of analytical solution to breakthrough curve measured by the 15 cases pumping tracer experiment. Consequently, we could evaluate the dispersion coefficients for 12 cases of 15 cases. Then, we discussed the relation between a injection-withdraw flow rate and a property of heterogeneous media and dispersion coefficient. The conclusions obtained from the results of the evaluation are summarized as follows, It was found that the macroscopic dispersion coefficients tend to be increased with increase of the average radius of tracer front spread around a single well. We have conducted any experiments with s single well settled at two positions. In case of that there is low permeability around a single well, we found dispersion coefficients are large. In case of that there is high permeability around a single well, we found dispersion coefficients are small. In three cases that we could not evaluate because of incorrect accuracy of fitting, we have found it possible that there is some points that dispersion coefficients were strikingly small in tracer front. (author)

  13. Zinc injection on the EDF pressurized light water reactors. Current results and operating experience feedback

    International Nuclear Information System (INIS)

    Piana, Olivier; Duval, Arnaud; Moleiro, Edgar; Benfarah, Moez; Bretelle, Jean-Luc; Chaigne, Guy

    2014-01-01

    Nowadays, zinc injection, as well as pH management and hydrogen control, is increasingly considered as an essential element of PWR Primary Water Chemistry worldwide. After a first implementation of zinc injection at Bugey 2 since 2004 and Bugey 4 since 2006, EDF decided to extend this practice, which constitutes a modification of primary circuit chemical conditioning, to other units of its fleet. Currently, 15 among the 58 reactors of the French fleet are injecting depleted zinc acetate into the primary coolant water. Three main goals were identified at the beginning of this program. Indeed, the expected benefits of zinc injection were: Reduction of the rate of generalized corrosion and mitigation of stress corrosion cracking initiation on nickel based alloys (Material goal). Curative or preventive reduction of radiation sources to which workers are exposed (Radiation fields' goal). Mitigation of the AOA or CIPS risks by reduction of corrosion products releases and mitigation of crud deposition (Fuel protection goal). To monitor the zinc addition, EDF has defined a complete survey program concerning: chemistry and radiochemistry responses (primary coolant monitoring of corrosion and fission products and calculation of zinc injected, zinc removed and zinc incorporated in RCS surfaces) ; radiation fields (dose rates and deposited activities measurements) ; materials (statistical analysis of SG tube cracks) ; fuel (oxide thickness measurements and visual exams) ; effluents (corrosion products releases and isotopic distribution follow up) ; wastes (radiochemical characterization of filters). This paper will detail the present results of this monitoring program. It appears that the expected benefits of zinc injection have yet to be fully realized; further operating experience will be required in order to fully evaluate its impact. (author)

  14. Experiment HFR-B1: A preliminary analysis of the water-vapor injection experiments in capsule 3

    International Nuclear Information System (INIS)

    Myers, B.F.

    1993-01-01

    A preliminary analysis of the response of uranium oxycarbide (UCO) fuel to water vapor addition in capsule 3 of experiment HFR-B1 (HFR-B1/3) has been conducted. The analysis provides an early indication of the behavior of fission gas release under a wider range of water-vapor pressures and of temperatures than heretofore studied. A preliminary analysis of selected aspects of the water-vapor injection tests in capsule 3 of experiment HFR-B1 is presented. The release of fission gas stored in bubbles and the diffusive release of fission-gas atoms are distinguished. The dependence of the release of stored fission gas ( 85m Kr) on water-vapor pressure, P(H 2 O), and temperature were established taking into account the contributing mechanisms of gaseous release, the effect of graphite hydrolysis, and the requirement of consistency with experiment HRB-17 in which similar water-vapor injection tests were conducted. The dependence on P(H 2 O) becomes weaker as temperatures increase above 770 degree C; the activation energy for release of stored-fission gas is 393 kJ/mol. Isorelease curves for the pressure-temperature plane were deduced from a derived functional relation. The stored-fission gas releases as a function of P(H 2 O) at a common temperature for experiments HFR-B1 and HRB-17 differ by a factor of 4; this discrepancy could be attributed to the differences in fission-rate density and neutron flux between the two experiments. Diffusive release of fission gas occurred during and after the release of stored gas. The ratio of diffusive release during water-vapor injection to that prior to injection varied in contrast to the results from HRB-17. The variation was attributed to the practice of injecting water vapor into HFR-B1 before sintering of the fuel, hydrolyzed in the previous test, was completed. The derived activation energy for diffusive release is 23.6 kJ/mol

  15. Experiment HFR-B1: A preliminary analysis of the water-vapor injection experiments in capsule 3

    Energy Technology Data Exchange (ETDEWEB)

    Myers, B.F.

    1993-08-01

    A preliminary analysis of the response of uranium oxycarbide (UCO) fuel to water vapor addition in capsule 3 of experiment HFR-B1 (HFR-B1/3) has been conducted. The analysis provides an early indication of the behavior of fission gas release under a wider range of water-vapor pressures and of temperatures than heretofore studied. A preliminary analysis of selected aspects of the water-vapor injection tests in capsule 3 of experiment HFR-B1 is presented. The release of fission gas stored in bubbles and the diffusive release of fission-gas atoms are distinguished. The dependence of the release of stored fission gas ({sup 85m}Kr) on water-vapor pressure, P(H{sub 2}O), and temperature were established taking into account the contributing mechanisms of gaseous release, the effect of graphite hydrolysis, and the requirement of consistency with experiment HRB-17 in which similar water-vapor injection tests were conducted. The dependence on P(H{sub 2}O) becomes weaker as temperatures increase above 770{degree}C; the activation energy for release of stored-fission gas is 393 kJ/mol. Isorelease curves for the pressure-temperature plane were deduced from a derived functional relation. The stored-fission gas releases as a function of P(H{sub 2}O) at a common temperature for experiments HFR-B1 and HRB-17 differ by a factor of 4; this discrepancy could be attributed to the differences in fission-rate density and neutron flux between the two experiments. Diffusive release of fission gas occurred during and after the release of stored gas. The ratio of diffusive release during water-vapor injection to that prior to injection varied in contrast to the results from HRB-17. The variation was attributed to the practice of injecting water vapor into HFR-B1 before sintering of the fuel, hydrolyzed in the previous test, was completed. The derived activation energy for diffusive release is 23.6 kJ/mol.

  16. Fat injection to correct contour deformities of the reconstructed breast: a single surgeon experience

    Directory of Open Access Journals (Sweden)

    Youssef Tahiri

    2015-06-01

    Full Text Available Aim: Autologous fat grafting has gained acceptance as a technique to improve aesthetic outcomes in breast reconstruction. The purpose of this study was to share our clinical experience using autologous fat injection to correct contour deformities during breast reconstruction. Methods: A single surgeon, prospectively maintained database of patients who underwent autologous fat injection during breast reconstruction from January 2008 to November 2013 at McGill University Health Center was reviewed. Patient characteristics, breast history, type of breast reconstruction, volume of fat injected, and complications were analyzed. Results: One hundred and twenty-four patients benefited from autologous fat injection from January 2008 to November 2013, for a total of 187 treated breasts. The patients were on average 49.3 years old (΁ 8.9 years. Fat was harvested from the medial thighs (20.5%, flanks (39.1%, medial thighs and flanks (2.9%, trochanters (13.3%, medial knees (2.7%, and abdomen (21.9%. An average of 49.25 mL of fat was injected into each reconstructed breast. A total of 187 breasts in 124 patients were lipo-infiltrated during the second stage of breast reconstruction. Thirteen breasts (in 12 separate patients were injected several years after having undergone lumpectomy and radiotherapy. Of the 187 treated breasts, 118 were reconstructed with expanders to implants, 45 with deep inferior epigastric perforator flaps, 9 with latissimus dorsi flaps with implants, 4 with transverse rectus abdominis myocutaneous flaps, and 13 had previously undergone lumpectomy and radiotherapy. Six complications were noted in the entire series, for a rate of 3.2%. All were in previously radiated breasts. Average follow-up time was 12 months (range: 2-36 months. Conclusion: Fat injection continues to grow in popularity as an adjunct to breast reconstruction. Our experience demonstrates a low complication rate as compared to most surgical interventions of the breast

  17. Large break LOCA analysis for retrofitted ECCS at MAPS using modified computer code ATMIKA

    International Nuclear Information System (INIS)

    Singhal, Mukesh; Khan, T.A.; Yadav, S.K.; Pramod, P.; Rammohan, H.P.; Bajaj, S.S.

    2002-01-01

    Full text: Computer code ATMIKA which has been used for thermal hydraulic analysis is based on unequal velocity equal temperature (UVET) model. Thermal hydraulic transient was predicted using three conservation equations and drift flux model. The modified drift flux model is now able to predict counter current flow and the relative velocity in vertical channel more accurately. Apart from this, stratification model is also introduced to predict the fuel behaviour under stratified condition. Many more improvements were carried out with respect to solution of conservation equation, heat transfer package and frictional pressure drop model. All these modifications have been well validated with published data on RD-12/RD-14 experiments. This paper describes the code modifications and also deals with the application of the code for the large break LOCA analysis for retrofitted emergency core cooling system (ECCS) being implemented at Madras Atomic Power Station (MAPS). This paper also brings out the effect of accumulator on stratification and fuel behaviour

  18. Operational experience with the Fermilab 150 GeV injection kicker

    International Nuclear Information System (INIS)

    Trendler, R.C.

    1985-01-01

    The Fermilab E17 injection kicker has been in operation for more than 12000 filament hours and has logged almost 350,000 pulses since commissioning without major failure. The kicker system uses EEV 1193B and 1193C double-ended thyratrons in the MAIN, CLIP and DUMP configuration. In typical operation, the pulser produces 4800 A, 20 μs pulses at a charging voltage of 60kV and is capable of operating at a 80kV charging voltage. Any failure of the injection process can cause the Tevatron cryogenic magnets to quench. This includes any misfires of the injection kicker. Considerable effort was made to maximize reliability and provide interlocks to limit the problems that could happen from injection kicker misfires. The operating experience and reliability of the EEV thyratron will be discussed. Also, the use of the fiber optics, unique charging power supplies, and unusual digital interlocks and the role they play in improved reliability will be discussed

  19. Core-power and decay-time limits for disabled automatic-actuation of LOFT ECCS

    International Nuclear Information System (INIS)

    Hanson, G.H.

    1978-01-01

    The Emergency Core Cooling System (ECCS) for the LOFT reactor may need to be disabled for modifications or repairs of hardware or instrumentation or for component testing during periods when the reactor system is hot and pressurized, or it may be desirable to enable the ECCS to be disabled without the necessity of cooling down and depressurizing the reactor. LTR 113-47 has shown that the LOFT ECCS can be safely bypassed or disabled when the total core power does not exceed 25 kW. A modified policy involves disabling the automatic actuation of the LOFT ECCS, but still retaining the manual activation capability. Disabling of the automatic actuation can be safely utilized, without subjecting the fuel cladding to unacceptable temperatures, when the LOFT power decays to 70 kW; this power level permits a maximum delay of 20 minutes following a LOCA for the manual actuation of ECCS

  20. Combined group ECC protection and subgroup parity protection

    Science.gov (United States)

    Gara, Alan G.; Chen, Dong; Heidelberger, Philip; Ohmacht, Martin

    2013-06-18

    A method and system are disclosed for providing combined error code protection and subgroup parity protection for a given group of n bits. The method comprises the steps of identifying a number, m, of redundant bits for said error protection; and constructing a matrix P, wherein multiplying said given group of n bits with P produces m redundant error correction code (ECC) protection bits, and two columns of P provide parity protection for subgroups of said given group of n bits. In the preferred embodiment of the invention, the matrix P is constructed by generating permutations of m bit wide vectors with three or more, but an odd number of, elements with value one and the other elements with value zero; and assigning said vectors to rows of the matrix P.

  1. ATX-101 (Deoxycholic Acid Injection) Treatment in Men: Insights From Our Clinical Experience.

    Science.gov (United States)

    Shridharani, Sachin M; Behr, Kathleen L

    2017-11-01

    Excess submental fat (SMF), also called a double chin, is an area of concern for men that can be addressed clinically. ATX-101 (deoxycholic acid injection; Kybella in the United States and Belkyra in Canada, Australia, and various European countries) is the first injectable approved for reduction of SMF. To share the authors' clinical experience using ATX-101 in men with submental fullness and offer insights regarding how this treatment may be presented to men as an option to improve their submental profile. Retrospective review of the authors' medical records for male patients treated with ATX-101. To allow for fewer ATX-101 treatments, it is recommended that a large surface area be treated at the first session. The positive changes and outcomes achieved with ATX-101 build confidence between the physician and patient, which often leads to male patients seeking other aesthetic treatments to improve their overall appearance. ATX-101 treatment is often an effective introduction to aesthetic medicine for men.

  2. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1976-09-01

    Thermo-hydraulic behavior in the primary cooling system of a pressurized water reactor with an upper head injection system (UHI) in a postulated loss-of-coolant accident (LOCA) has been studied with ROSA-II test facility. Simulated UHI and internal structures of the pressure vessel were installed to the facility for the experiment. Nine maximum-sized double-ended break tests and one medium-sized split break test were performed for the cold-leg break condition. The results are as follows: (1) Fluid mixing in the upper head is not perfect. (2) Cold water injection into the steam or two-phase fluid causes violent depressurization due to the condensation. Flow pattern in the primary cooling system is largely influenced by the above two. (auth.)

  3. Prompt Loss of Energetic Ions during Early Neutral Beam Injection in the National Spherical Torus Experiment

    International Nuclear Information System (INIS)

    Medley, S.S.; Darrow, D.S.; Liu, D.; Roquemore, A.L.

    2005-01-01

    Early neutral-beam injection is used in the National Spherical Torus Experiment (NSTX) to heat the electrons and slow current penetration which keeps q(0) elevated to avoid deleterious MHD activity and at the same time reduces Ohmic flux consumption, all of which aids long-pulse operation. However, the low plasma current (I p ∼ 0.5 MA) and electron density (n e ∼ 1 x 10 13 cm -3 ) attending early injection lead to elevated orbit and shine through losses. The inherent orbit losses are aggravated by large excursions in the outer gap width during current ramp-up. An investigation of this behavior using various energetic particle diagnostics on NSTX and TRANSP code analysis is presented

  4. Numerical analysis of experiments with gas injection into liquid metal coolant

    International Nuclear Information System (INIS)

    Usov, E V; Lobanov, P D; Pribaturin, N A; Mosunova, N A; Chuhno, V I; Kutlimetov, A E

    2016-01-01

    Presented paper contains results of a numerical analysis of experiments with gas injection in water and liquid metal which have been performed at the Institute of Thermophysics Russian Academy of Science (IT RAS). Obtained experimental data are very important to predict processes that take place in the BREST-type reactor during the hypothetical accident with damage of the steam generator tubes, and may be used as a benchmark to validate thermo-hydraulic codes. Detailed description of models to simulate transport of gas phase in a vertical liquid column is presented in a current paper. Two-fluid model with closing relation for wall friction and interface friction coefficients was used to simulate processes which take place in a liquid during injection of gaseous phase. It has being shown that proposed models allow obtaining a good agreement between experimental data and calculation results. (paper)

  5. Field experience on Zn injection on PWR plants with a view to dose rate reduction

    International Nuclear Information System (INIS)

    Roumiguiere, F.

    2005-01-01

    Operating experience acquired at PWR plants shows that zinc injection in the primary coolant at low concentration (∼5 ppb) is a very effective tool to achieve a reduction of the dose rate build-up. The beneficial effect of zinc consists on improving the protective layer characteristics of the reactor coolant system surfaces, which results in a lower pickup of activated products (Co-60, Co-58), and consequently a reduction of the associated dose rates. Zinc injection was introduced at the Unit B of the Biblis Power Station in September 1996 and at the Obrigheim Nuclear Power Station in February 1998, as a measure for reduction of radiation fields. The effectiveness of the method and its compatibility with the overall plant was examined in a rather comprehensive surveillance program at these plants. The already published data show that zinc injection did not lead to any operating restrictions or other negative effects on plants systems and components. Zinc injection is still being implemented today at these plants. Zinc injection is considered today as a mature technique and is now being successfully applied at a number of PWRs in Germany, Brazil, USA and Japan, with the support of Framatome-ANP. Several PWRs in Europe and Asia are preparing for zinc chemistry in the near future. The method is inexpensive and easy to apply. Its implementation is highly advisable in terms of the cost/benefit criterion following the ALARA principle. This paper gives an overview of the experience gathered with the method. The main subject addressed by the paper is the evolution of dose rates at the primary system and work-related doses since introduction of the method. In German PWRs with Incoloy 800 steam generator tubing material (Ni-content ∼32%), the observed reductions correspond to a decrease in dose rates of around 10 to 15% per year following, as predicted, the half-life time of 60 Co. Overall reductions in high radiation areas are now in the range of 50% after 5 years of

  6. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  7. Natural gas extraction and artificial gas injection experiments in Opalinus Clay, Mont Terri rock laboratory (Switzerland)

    Energy Technology Data Exchange (ETDEWEB)

    Vinsot, A.; Lundy, M. [Agence Nationale pour la Gestion des Déchets Radioactifs ANDRA, Meuse Haute-Marne Center, Bure (France); Appelo, C.A.J. [Dr C.A.J. Appelo, Hydrochemical Consultant, Amsterdam (Netherlands); and others

    2017-04-15

    Two experiments have been installed at Mont Terri in 2004 and 2009 that allowed gas circulation within a borehole at a pressure between 1 and 2 bar. These experiments made it possible to observe the natural gases that were initially dissolved in pore-water degassing into the borehole and to monitor their content evolution in the borehole over several years. They also allowed for inert (He, Ne) and reactive (H{sub 2}) gases to be injected into the borehole with the aim either to determine their diffusion properties into the rock pore-water or to evaluate their removal reaction kinetics. The natural gases identified were CO{sub 2}, light alkanes, He, and more importantly N{sub 2}. The natural concentration of four gases in Opalinus Clay pore-water was evaluated at the experiment location: N{sub 2} 2.2 mmol/L ± 25%, CH{sub 4} 0.30 mmol/L ± 25%, C{sub 2}H{sub 6} 0.023 mmol/L ± 25%, C{sub 3}H{sub 8} 0.012 mmol/L ± 25%. Retention properties of methane, ethane, and propane were estimated. Ne injection tests helped to characterize rock diffusion properties regarding the dissolved inert gases. These experimental results are highly relevant towards evaluating how the fluid composition could possibly evolve in the drifts of a radioactive waste disposal facility. (authors)

  8. Design calculations for a combined ventilation and brine injection experiment at the Grimsel Rock Laboratory, Switzerland

    International Nuclear Information System (INIS)

    Finsterle, S.; Pruess, K.

    1993-07-01

    A combined ventilation and brine injection test is planned at the Grimsel Test Site. The objective of the experiment is to study the transport of liquid and gas in the vicinity of a ventilated drift in order to evaluate the impact of the drying process on the characterization of the rock matrix. The proposed test sequence includes a desaturation-resaturation cycle. In addition, brine and fresh water will be injected from a borehole as trace electrolytes in order to better track the propagation of the individual phases. Results of design calculations using the TOUGH2 code show that injection of brine may significantly influence the unsaturated flow behavior by changing the pressure and saturation distribution around the borehole. Transport velocity is predicted to be very slow, requiring several months for the brine to reach the draft wall. However, the presence of preferential flow paths may reduce travel time and alter brine content and saturation distribution so that certain sensors may respond earlier or not at all

  9. Plasma jet source parameter optimisation and experiments on injection into Globus-M spherical tokamak

    International Nuclear Information System (INIS)

    Gusev, V.K.; Petrov, Yu.V.; Sakharov, N.V.; Semenov, A.A.; Voronin, A.V.

    2005-01-01

    Results of theoretical and experimental research on the plasma sources and injection of plasma and gas jet produced by the modified source into tokamak Globus-M are presented. An experimental test stand was developed for investigation of intense plasma jet generation. Optimisation of pulsed coaxial accelerator parameters by means of analytical calculations is performed with the aim of achieving the highest flow velocity at limited coaxial electrode length and discharge current. The optimal parameters of power supply to generate a plasma jet with minimal impurity contamination and maximum flow velocity were determined. A comparison of experimental and calculation results is made. Plasma jet parameters are measured, such as: impurity species content, pressure distribution across the jet, flow velocity, plasma density, etc. Experiments on the interaction of a higher kinetic energy plasma jet with the magnetic field and plasma of the Globus-M tokamak were performed. Experimental results on plasma and gas jet injection into different Globus-M discharge phases are presented and discussed. Results are presented on the investigation of plasma jet injection as the source for discharge breakdown, plasma current startup and initial density rise. (author)

  10. High-beta experiments with neutral-beam injection on PDX

    International Nuclear Information System (INIS)

    Johnson, D.; Bell, M.; Bitter, M.

    1983-01-01

    Experimental investigations of high-beta plasmas produced in PDX with near-perpendicular neutral-beam injection are reported. Systematic power scans have been performed over a wide range of toroidal fields (νsub(T)q.7 T< Bsub(T)<2.2 T) and plasma currents (200 kA< Isub(p)<500 kA). At high toroidal fields, the change in total stored energy due to beam injection increases linearly with input power and also increases with plasma current. At lower toroidal fields and low injection power levels, the stored energy also increases with power and plasma current. However, at high power and low toroidal fields, a saturation in heating is observed. This result suggests the onset of a νsub(T) limit for circular cross-section tokamaks with near-perpendicular injection. Scaling experiments indicate that this νsub(T) limit increases with rising 1/q. Values of νsub(T)approx.=3% at qsub(PSI)=1.8 have been achieved. At high values of νsub(T)q, short bursts of MHD activity are observed, synchronized with sharply increased fluxes of perpendicular charge-exchange neutrals and rapid decreases in the rate of beam-driven neutron production. When strong bursts occur, there is a significant depletion of the fast-ion population. Estimates of the fast-ion loss indicate that it could explain the observed decrease in heating, although an additional reduction in thermal-plasma confinement cannot be ruled out. Numerical studies using measured pressure profiles predict that the equilibria obtained become unstable to the ideal n=1 internal mode, at about the same value of 0 where the new fluctuations are observed. (author)

  11. Modeling injected interstitial effects on void swelling in self-ion irradiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Short, M.P., E-mail: hereiam@mit.edu [Dept. of Nuclear Science and Engineering, Massachusetts Institute of Technology (United States); Gaston, D.R. [Idaho National Laboratory (United States); Jin, M. [Dept. of Nuclear Science and Engineering, Massachusetts Institute of Technology (United States); Shao, L. [Dept. of Nuclear Engineering, Texas A& M University (United States); Garner, F.A. [Radiation Effects Consulting, LLC (United States)

    2016-04-01

    Heavy ion irradiations at high dose rates are often used to simulate slow and expensive neutron irradiation experiments. However, many differences in the resultant modes of damage arise due to unique aspects of heavy ion irradiation. One such difference was recently shown in pure iron to manifest itself as a double peak in void swelling, with both peaks located away from the region of highest displacement damage. In other cases involving a variety of ferritic alloys there is often only a single peak in swelling vs. depth that is located very near the ion-incident surface. We show that these behaviors arise due to a combination of two separate effects: 1) suppression of void swelling due to injected interstitials, and 2) preferential sinking of interstitials to the ion-incident surface, which are very sensitive to the irradiation temperature and displacement rate. Care should therefore be used in collection and interpretation of data from the depth range outside the Bragg peak of ion irradiation experiments, as it is shown to be more complex than previously envisioned. - Highlights: • A model of the spatially dependent point defect kinetics equations with injected interstitials has been implemented. • The results predict a double peak in the void nucleation rate, helping to explain a recent experiment. • The double peak is predicted to be evident within a narrow (+/− 30 °C) temperature window for self-irradiation of pure iron. • The ballistic damage profile may not match the resultant void swelling profile from ion irradiation experiments.

  12. Incarceration experiences among a community-recruited sample of injection drug users in Bangkok, Thailand

    Directory of Open Access Journals (Sweden)

    Lai Calvin

    2009-12-01

    Full Text Available Abstract Background Since 2003 Thailand has waged an aggressive "war on drugs" campaign focused on arresting and incarcerating suspected drug users and dealers. However, little is known about incarceration experiences among IDU in the wake of the recent war on drugs. Therefore, we sought to examine incarceration experiences among IDU in Bangkok, Thailand. Methods We examined the prevalence of incarceration among community-recruited IDU participating in the Mitsampan Community Research Project. Multivariate logistic regression was used to identify factors associated with a self-reported history of incarceration. We also examined the prevalence of injection drug use and syringe sharing within prisons. Results 252 IDU were recruited in August 2008; 66 (26.2% were female and the median age was 36.5 years. In total, 197 (78.2% participants reported a history of incarceration. In multivariate analyses, reporting a history of incarceration was associated with a history of compulsory drug treatment (adjusted odds ratio [AOR] = 4.93; 95% confidence interval [CI]: 1.95 - 12.48, non-fatal overdose (AOR = 3.69; 95%CI: 1.45 - 9.39, syringe sharing (AOR = 2.20; 95%CI: 1.12 - 4.32, and female gender (AOR = 0.41; 95%CI: 0.20 - 0.82. Among those who reported a history of incarceration, 59 (29.9% reported injection drug use in prison, and 48 (81.4% of these individuals reported sharing syringes in prison. Incarceration was not associated with the number of injections performed in the previous week (p = 0.202. Conclusion Over three-quarters of the IDU participating in this study reported a history of incarceration, and 30% of these individuals reported injection drug use within prison. Further, an alarmingly high level of syringe sharing within prison was reported, and incarceration was not associated with reductions in drug use. These findings provide further evidence of the need for community diversion strategies, as well as harm reduction programs, in Thai

  13. Predictive Eco-Cruise Control (ECC) system : model development, modeling and potential benefits.

    Science.gov (United States)

    2013-02-01

    The research develops a reference model of a predictive eco-cruise control (ECC) system that intelligently modulates vehicle speed within a pre-set speed range to minimize vehicle fuel consumption levels using roadway topographic information. The stu...

  14. Application of Interfacial Propagation and Kinking Crack Concept to ECC/Concrete Overlay Repair System

    Directory of Open Access Journals (Sweden)

    Yaw ChiaHwan

    2014-01-01

    Full Text Available Research on the application of ultraductile engineered cementitious composite (ECC as overlay in the repair of deteriorated concrete structures is performed in this paper. Also, interfacial crack kinking and trapping mechanism experimentally observed in ECC/concrete overlay repair system are described by comparison of toughness and energy release rate. The mechanism involves cycles of extension, kinking, and arrest of interfacial crack into the overlay. Experimental testing of overlay repair system reveals significant improvements in load carrying capacity and ductility over conventional concrete overlay. The commonly observed overlay system failure mode of delamination or spalling is eliminated when ECC is applied. These failure modes are suppressed when ECC is used as an ideal and durable candidate overlay repair material.

  15. Preestrita pihtimus : Friedrich Nietzsche ja tema substantsiaalne mina (Ecce homo) / Jaan Undusk

    Index Scriptorium Estoniae

    Undusk, Jaan, 1958-

    1998-01-01

    Varem ilmunud raamatu järelsõnana: Nietzsche, Friedrich. Ecce homo : kuidas saadakse selleks, mis ollakse / tlk. Jaan Undusk. Tallinn : Vagabund, 1996. Sisu: Poeetiline, filosoofiline, dionüüsiline kaanon ; Künism contra hulluskahtlus ; Antikristlik pihtimus ; Egoretoorika

  16. Recent results from the HIT-II and HIT-SI helicity injection current drive experiments

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Hamp, W.T.; Izzo, V.A.; Nelson, B.A.; O'Neill, R.G.; Raman, R.; Redd, A.J.; Sieck, P.E.; Smith, R.J.

    2005-01-01

    Three important results are reported. 1) CHI startup has produced 100 kA of closed current without using poloidal field (PF) coils or any transformer action. The initial equilibrium is then driven to 240 kA with a 3 V transformer loop voltage, indicating high quality plasma. 2) For the first time CHI alone has produced toroidal currents (350 kA) that far exceed q a I inj , and with I p /I tf as high as 1.2. The key to these new results appears to be having the toroidal field small enough that relaxation will occur. 3) The steady inductive helicity injection spheromak experiment has operated at 5 kHz for 6 ms with current amplitudes up to 11 kA in each injector. The helicity injection rate is nearly constant with the ExB flow always into the plasma and not into the walls. NIMROD simulations of HIT-SI show a buildup of spheromak fields. (author)

  17. Modelling of Pesticide Transport During An Injection Experiment In A Physical and Geochemical Heterogeneous Aquifer

    Science.gov (United States)

    Hojberg, A. L.; Engesgaard, P.; Bjerg, P. L.

    The fate of selected pesticides under natural groundwater conditions was studied by natural gradient short and long term injection experiments in a shallow uncon- fined aerobic aquifer. Bentazone, DNOC, MCPP, dichlorprop, isoproturon, and BAM (dichlobenil metabolite) were injected in aqueous solution with bromide as a nonre- active tracer. The Bromide and pesticide plumes were sampled during the initial 25 m of migration in a dense monitoring net of multilevel samplers. The aquifer was physical and geochemical heterogeneous, which affected transport of several of the pesticides. A 3D reactive transport code was developed including one- and two-site linear/nonlinear equilibrium/nonequilibrium sorption and first-order as well as single Monod degradation kinetic coupled to microbial growth. Model simulations demon- strated that microbial growth was likely supported by the phenoxy acids MCPP and dichlorprop, while degradation of DNOC was adequately described by first-order degradation with no initial lag time. An observed vertical increase in pH was observed at the site and implemented in the transport code. The numerical analysis indicated that degradation of the three degradable pesticides may have been affected by vertical pH variations. Spatial variability in observed DNOC sorption was similarly suspected to be an effect of varying pH. pH dependency on DNOC sorption was confirmed by the model recognized by a match to observed breakthrough at the individual sampling points, when pH variation was included in the simulations.

  18. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego.

    Science.gov (United States)

    Wood, Emily F; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Cuevas Mota, Jazmine; Garfein, Richard S; Strathdee, Steffanie A; Wagner, Karla D

    2017-03-01

    powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Differential experiences of Mexican policing by people who inject drugs residing in Tijuana and San Diego

    Science.gov (United States)

    Wood, Emily F.; Werb, Dan; Beletsky, Leo; Rangel, Gudelia; Mota, Jazmine Cuevas; Garfein, Richard S.; Strathdee, Steffanie A.; Wagner, Karla D.

    2017-01-01

    feelings of stress, anxiety, and powerlessness. This was less common among San Diego-based participants, who mostly attempted to avoid contact with LEOs in Mexico while engaging in risky injection behavior. Conclusion Experiences of discrimination and stigma were reported by a larger proportion of PWIDs living in Mexico, suggesting that they may be subject to greater health harms related to policing practices compared with those residing in the USA. Our findings reinforce the importance of efforts to curb abuse and align policing practices with public health goals in both the US and Mexico. PMID:28111221

  20. Numerical simulation of MH growth/dissociation by hot water injection on the Lab. experiment

    Science.gov (United States)

    Temma, N.; Sakamoto, Y.; Komai, T.; Yamaguchi, T.; Pawar, R.; Zyvoloski, G.

    2005-12-01

    Methane Hydrate (MH) is considered to be one of the new-generation energy resources. Aiming to develop the method of extraction of methane gas from MH, laboratory experiments have been performed in order to grasp the MH property in the National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba in Japan. In this paper, we present the results of the numerical simulation of experiment using by the hot water injection. In this calculation, FEHM (Finite Element Heat and Mass transfer) code is used. This code is developed at Los Alamos National Laboratory. In this experiment, temperature, pressure and cumulative gas production were measured. From these data, we suppose that MH growth/dissociation occurred by the flow of the hot water. And we make the model of the growth/dissociation. As this model consist of many parameters, it is difficult to determine parameters. Thus, we use PEST (Parameter ESTimation ) in order to determine parameters for the model of the MH growth/ dissociation. We use temperature data of experiment, as observed data. We make two observed data sets at the beginning and later term of experiment. At the results of PEST, we obtain two sets of parameters to get good match the observed data. We think that these sets indicate both the maximum and the minimum values of the MH growth/dissociation model. And, on this range, we continue to calculate until we get the good match. Finally, we obtain the numerical model of the experiment. Also, we conducted the sensitive analysis for the MH growth/ dissociation using this model.

  1. Effect of capillary number on the oil recovery using oil-water emulsion injection in core flooding experiments

    Energy Technology Data Exchange (ETDEWEB)

    Guillen Nunez, Victor Raul; Carvalho, Marcio da Silveira [Pontifical Catholic University of Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. of Mechanical Engineering], E-mail: msn@puc-rio.br; Basante, Vladimir Alvarado [University of Wyoming, Laramie, WY (United States). Dept. of Chemical/Petroleum Engineering], E-mail: valvard@uwyo.edu

    2010-07-01

    The Water injection flooding is a common method to improve reservoir sweep and pressure maintenance. The heavy-oil-recovery efficiency is in part limited by the high water-to-oil mobility ratio. Several enhanced oil recovery methods are being developed as more efficient alternatives to water flooding. Dispersion injection, in particular oil-water emulsion injection, has been tried with relative success as an enhanced oil recovery method, but the technique is not fully developed or understood. If emulsion injection proves to be an effective EOR method, its use would bring the added benefit of disposing produced water with small oil content that could be modified to serve as the injected oil-water emulsion. The use of such methods requires a detailed analysis of the different flow regimes of emulsions through the porous space of a reservoir rock. If the drop size of the disperse phase is of the same order of magnitude as the pore size, the drops may agglomerate and partially block water flow through pores. This flow regime may be used to control the mobility of the injected liquid, leading to higher recovery factor. We have shown in recent experiments of oil displacement in a sandstone core that, the oil recovery factor could be raised from approximately 40 %, obtained with water injection only, up to approximately 75 % by alternating water and emulsion injection. Although these results clearly show the improvement in the recovery factor, the mechanisms responsible for the phenomenon have not been clearly elucidated. In this work, two sandstone cores were used to demonstrate the effect of flow rate (capillary number) on the mobility control by emulsion injection. Figure 1 shows a schematic representation of the experiment set-up. The experiments show that raising the flow rate by a factor of 10 (0.03 ml/min to 0.3 ml/min), the oil recovered factor decreases considerably. (author)

  2. VUV spectroscopy in impurity injection experiments at KSTAR using prototype ITER VUV spectrometer

    Science.gov (United States)

    Seon, C. R.; Hong, J. H.; Song, I.; Jang, J.; Lee, H. Y.; An, Y. H.; Kim, B. S.; Jeon, T. M.; Park, J. S.; Choe, W.; Lee, H. G.; Pak, S.; Cheon, M. S.; Choi, J. H.; Kim, H. S.; Biel, W.; Bernascolle, P.; Barnsley, R.

    2017-08-01

    The ITER vacuum ultra-violet (VUV) core survey spectrometer has been designed as a 5-channel spectral system so that the high spectral resolving power of 200-500 could be achieved in the wavelength range of 2.4-160 nm. To verify the design of the ITER VUV core survey spectrometer, a two-channel prototype spectrometer was developed. As a subsequent step of the prototype test, the prototype VUV spectrometer has been operated at KSTAR since the 2012 experimental campaign. From impurity injection experiments in the years 2015 and 2016, strong emission lines, such as Kr xxv 15.8 nm, Kr xxvi 17.9 nm, Ne vii 46.5 nm, Ne vi 40.2 nm, and an array of largely unresolved tungsten lines (14-32 nm) could be measured successfully, showing the typical photon number of 1013-1015 photons/cm2 s.

  3. An anaerobic field injection experiment in a landfill leachate plume (Grindsted, Denmark)

    DEFF Research Database (Denmark)

    Albrechtsen, Hans-Jørgen; Bjerg, Poul Løgstrup; Ludvigsen, L.

    1999-01-01

    Redox conditions may be environmental factors which affect the fate of the xenobiotic organic compounds. Therefore the redox conditions were characterized in an anaerobic, leachate-contaminated aquifer 15–60 m downgradient from the Grindsted Landfill, Denmark, where an field injection experiment...... was carried out. Furthermore, the stability of the redox conditions spatially and over time were investigated, and different approaches to deduce the redox conditions were evaluated. The redox conditions were evaluated in a set of 20 sediment and groundwater samples taken from locations adjacent...... to the sediment samples. Samples were investigated with respect to groundwater chemistry, including hydrogen and volatile fatty acids (VFAs) and sediment geochemistry, and bioassays were performed. The groundwater chemistry, including redox sensitive species for a large number of samples, varied over time during...

  4. An analysis of the SCEX 3 ionospheric electron beam injection experiment

    International Nuclear Information System (INIS)

    Goerke, R.T.

    1992-01-01

    The SCEX 3 experiment (Several Compatible EXperiments using a rocket-borne accelerator) was carried to ionospheric altitudes (375 km) by a Black Brant 11 rocket on February 1, 1990. The experiment was launched from Poker Flat Research Range (65.1 degree N, 147.5 degree W) at 1207 UT. The payload split into two parts (hereafter forward and aft payloads) 116 seconds after launch. The aft payload carried two electron accelerators as well as several diagnostic instruments. The forward payload was ejected at an angle of 6 degree with the magnetic field in a northwesterly direction. This payload carried a multiband plasma wave receiver and various particle detectors to make in situ measurements of the Beam Plasma Interaction (BPI) region. Two Throw Away Detectors (TAD's 1 and 2) were also ejected from the aft payload in the east and west directions respectively. TAD 1 also carried a multiband plasma wave receiver. Preceding the launch an auroral arch along the southern boundary of a diffuse auroral patch suddenly brightened, split into two separate arcs and moved to a position north of the rocket's trajectory. SCEX 3 was launched into an active breakup aurora consisting of tall rays and diffuse patches. The purpose of this experiment were (1) to observe injected electrons reflected from the naturally occurring parallel electric field structures which are thought to accelerate the auroral electron, (2) to observe a variety of plasma effects caused by the artificial electron beam and the associated spacecraft charging, and (3) study the natural phenomena associated with auroral activity. This work is a summary of the interesting observations made by the SCEX 3 experiment. These observations include VHF emissions produced by the electron beam via the Beam Plasma Discharge (BPD), Diffuse resonance emissions by the hot plasma region surrounding the electron beam and auroral Z-mode emissions

  5. Interaction of Liquid Film Flow of Direct Vessel Injection Under the Cross Directional Gas Flow

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-sol; Lee, Jae-young [Handong Global University, Pohang (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In order to obtain a proper scaling law of the flow, local information of the flow was investigated experimentally and also numerically. A series of experiments were conducted in the 1/20 modified linear scaled plate type test rig to analyze a liquid film from ECC water injection through the DVI nozzle to the downcomer wall. The present study investigates liquid film flow generated in a downcomer of direct vessel injection (DVI) system which is employed as an emergency core cooling (ECC) system during a loss of coolant accident in the Korea nuclear power plant APR1400. During the late reflooding, complicated multi-phase flow phenomena including the wavy film flow, film breakup, entrainment, liquid film shift due to interfacial drag and gas jet impingement occur. A confocal chromatic sensor was used to measure the local instantaneous liquid film thickness and a hydraulic jump in the film flow and boundaries of the film flow. It was found that CFD analysis results without surface tension model showed some difference with the data in surface tension dominated flow region. For the interaction between a liquid film and gas shear flow, CFD results make a good agreement with the real liquid film dynamics in the case of low film Reynolds number or low Weber number flow. In the 1/20 scaled plate type experiment and simulation, the deformed spreading profile results seem to accord with each other at the relatively low We and Re regime.

  6. FPGA implementation of PCI to CAMAC interface for Embedded CAMAC Controller (ECC)

    International Nuclear Information System (INIS)

    Jha, K.; Behere, Anita; Ghodgaonkar, M.D.

    2005-01-01

    CAMAC controllers are used for control systems and nuclear physics experiments. Control applications need more number of physically distributed crates with regular scanning of all the parameters, the control being with a centralized computer. On the other hand, nuclear physics experiments need a high throughput with a large number of parameters in one or more crates. The nature of events is random hence buffering of data in LIST mode acquisition is needed. For a large number of parameters, this translates to high transfer rate. Hence it is essential that the CAMAC readout time is minimized and also the data transfer speed is improved to achieve maximum effective throughput. The ECC is designed to achieve these objectives using an embedded controller with PC architecture having PCI bus as interface for add on logic. The PCI Add-on to CAMAC interface protocol has been implemented in an AL TERA FPGA and all the functionality coded in VHDL. This paper discusses the design aspects of the FPGA implementation of the PCI to CAMAC interface. (author)

  7. Formation and sustainment of a very low aspect ratio tokamak using coaxial helicity injection (the Helicity Injected Torus [HIT] experiment)

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Nelson, B.A.

    1992-01-01

    In the paper we will detail the progress of the HIT experiment construction, including the following components: preliminary data and interpretation; diagnostic systems; vacuum vessel and pumping system; helicity source and power supplies; toroidal field coil and power supply; data acquisition system; collaboration with general atomics, with a brief summary given on each

  8. Seismic and aseismic fault slip in response to fluid injection observed during field experiments at meter scale

    Science.gov (United States)

    Cappa, F.; Guglielmi, Y.; De Barros, L.; Wynants-Morel, N.; Duboeuf, L.

    2017-12-01

    During fluid injection, the observations of an enlarging cloud of seismicity are generally explained by a direct response to the pore pressure diffusion in a permeable fractured rock. However, fluid injection can also induce large aseismic deformations which provide an alternative mechanism for triggering and driving seismicity. Despite the importance of these two mechanisms during fluid injection, there are few studies on the effects of fluid pressure on the partitioning between seismic and aseismic motions under controlled field experiments. Here, we describe in-situ meter-scale experiments measuring synchronously the fluid pressure, the fault motions and the seismicity directly in a fault zone stimulated by controlled fluid injection at 280 m depth in carbonate rocks. The experiments were conducted in a gallery of an underground laboratory in south of France (LSBB, http://lsbb.eu). Thanks to the proximal monitoring at high-frequency, our data show that the fluid overpressure mainly induces a dilatant aseismic slip (several tens of microns up to a millimeter) at the injection. A sparse seismicity (-4 laws, we simulated an experiment and investigated the relative contribution of the fluid pressure diffusion and stress transfer on the seismic and aseismic fault behavior. The model reproduces the hydromechanical data measured at injection, and show that the aseismic slip induced by fluid injection propagates outside the pressurized zone where accumulated shear stress develops, and potentially triggers seismicity. Our models also show that the permeability enhancement and friction evolution are essential to explain the fault slip behavior. Our experimental results are consistent with large-scale observations of fault motions at geothermal sites (Wei et al., 2015; Cornet, 2016), and suggest that controlled field experiments at meter-scale are important for better assessing the role of fluid pressure in natural and human-induced earthquakes.

  9. The experience of initiating injection drug use and its social context: a qualitative systematic review and thematic synthesis.

    Science.gov (United States)

    Guise, Andy; Horyniak, Danielle; Melo, Jason; McNeil, Ryan; Werb, Dan

    2017-12-01

    Understanding the experience of initiating injection drug use and its social contexts is crucial to inform efforts to prevent transitions into this mode of drug consumption and support harm reduction. We reviewed and synthesized existing qualitative scientific literature systematically to identify the socio-structural contexts for, and experiences of, the initiation of injection drug use. We searched six databases (Medline, Embase, PsychINFO, CINAHL, IBSS and SSCI) systematically, along with a manual search, including key journals and subject experts. Peer-reviewed studies were included if they qualitatively explored experiences of or socio-structural contexts for injection drug use initiation. A thematic synthesis approach was used to identify descriptive and analytical themes throughout studies. From 1731 initial results, 41 studies reporting data from 1996 participants were included. We developed eight descriptive themes and two analytical (higher-order) themes. The first analytical theme focused on injecting initiation resulting from a social process enabled and constrained by socio-structural factors: social networks and individual interactions, socialization into drug-using identities and choices enabled and constrained by social context all combine to produce processes of injection initiation. The second analytical theme addressed pathways that explore varying meanings attached to injection initiation and how they link to social context: seeking pleasure, responses to increasing tolerance to drugs, securing belonging and identity and coping with pain and trauma. Qualitative research shows that injection drug use initiation has varying and distinct meanings for individuals involved and is a dynamic process shaped by social and structural factors. Interventions should therefore respond to the socio-structural influences on injecting drug use initiation by seeking to modify the contexts for initiation, rather than solely prioritizing the reduction of individual

  10. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Comparison between gas puffing and supersonic molecular beam injection in plasma density feedback experiments in EAST

    International Nuclear Information System (INIS)

    Zheng, Xingwei; Li, Jiangang; Hu, Jiansheng; Li, Jiahong; Ding, Rui; Cao, Bin; Wu, Jinhua

    2013-01-01

    To achieve desirable plasma density control, a supersonic molecular beam injection (SMBI) feedback control system has been developed recently for the EAST tokamak. The performance of the SMBI and gas puffing (GP) feedback systems were used and compared. The performance of pulse width mode is better than that of pulse amplitude mode when GP was used for density feedback control. During one-day experiments, the variation of gas input and wall retention can be clarified into two stages. In the first stage the retention ratio is as high as 80–90%, and the gas input is about an order of 10 22 D 2 . However, in the second stage, the retention ratio is at a range of 50–70%. The gas input of a single discharge is small and the net wall retention grows slowly. The results of the SMBI feedback control experiment was analyzed. The shorter delay time of SMBI makes it faster at feeding back control the plasma density. The result showed that, compared with GP, the gas input of SMBI was decreased ∼30% and the wall retention was reduced ∼40%. This shows SMBI's advantage for the long pulse high density discharges in EAST. (paper)

  12. Local mechanical properties of LFT injection molded parts: Numerical simulations versus experiments

    Science.gov (United States)

    Desplentere, F.; Soete, K.; Bonte, H.; Debrabandere, E.

    2014-05-01

    In predictive engineering for polymer processes, the proper prediction of material microstructure from known processing conditions and constituent material properties is a critical step forward properly predicting bulk properties in the finished composite. Operating within the context of long-fiber thermoplastics (LFT, length Autodesk Simulation Moldflow Insight 2014 software has been used. In this software, a fiber breakage algorithm for the polymer flow inside the mold is available. Using well known micro mechanic formulas allow to combine the local fiber length with the local orientation into local mechanical properties. Different experiments were performed using a commercially available glass fiber filled compound to compare the measured data with the numerical simulation results. In this investigation, tensile tests and 3 point bending tests are considered. To characterize the fiber length distribution of the polymer melt entering the mold (necessary for the numerical simulations), air shots were performed. For those air shots, similar homogenization conditions were used as during the injection molding tests. The fiber length distribution is characterized using automated optical method on samples for which the matrix material is burned away. Using the appropriate settings for the different experiments, good predictions of the local mechanical properties are obtained.

  13. Evaluation of patients’ experiences at different stages of the intravitreal injection procedure – what can be improved?

    Directory of Open Access Journals (Sweden)

    Tailor R

    2011-10-01

    Full Text Available Rajen Tailor, Rebecca Beasley, Yit Yang, Niro NarendranWolverhampton and Midland Counties Eye Infirmary, New Cross Hospital, Wolverhampton, UKIntroduction: Intravitreal injection of ranibizumab has become one of the most commonly performed ophthalmic procedures. It is timely to conduct an evaluation of the injection procedure from the patient’s perspective so as to determine ways to improve patient experience. The purpose of this study was to quantitatively describe patients’ experiences of the different stages of the intravitreal injection procedure and provide suggestions for improvement.Method: Following intravitreal injection, patients were administered a questionnaire to score the distress felt for each of ten parts of the whole injection process from the initial waiting to the final instillation of topical antibiotic at the end. A score of higher than 4 was regarded as significantly unpleasant. The proportion of scores above 4 for each step was used to evaluate the relative distress experienced by patients for the different parts of the procedure.Results: A total of 42 patients were surveyed. The step with the highest percentage of patients scoring more than 4 was the injection step (19%. However, cumulatively, the steps relating to the application of the drape, the speculum, and the removal of drape accounted for 53% of scores greater than 4.Conclusion: There is considerable variation in how patients tolerate different stages of the injection procedure. The needle entry was the most unpleasant step followed by the draping steps cumulatively. Use of subconjunctival anesthesia, a perforated drape, and alternative lid exclusion devices may help to improve the patient’s tolerability of the procedure and experience.Keywords: ranibizumab, patient experience, age-related macular degeneration

  14. Suppression of Alfven Modes on the National Spherical Torus Experiment Upgrade with Outboard Beam Injection [Suppression of Alfven Modes on the NSTX-U with Outboard Beam Injection

    International Nuclear Information System (INIS)

    Fredrickson, E. D.; Belova, E. V.; Battaglia, D. J.

    2017-01-01

    In this paper we present data from experiments on the National Spherical Torus Experiment Upgrade, where it is shown for the first time that small amounts of high pitch-angle beam ions can strongly suppress the counterpropagating global Alfven eigenmodes (GAE). GAE have been implicated in the redistribution of fast ions and modification of the electron power balance in previous experiments on NSTX. The ability to predict the stability of Alfven modes, and developing methods to control them, is important for fusion reactors like the International Tokamak Experimental Reactor, which are heated by a large population of nonthermal, super-Alfvenic ions consisting of fusion generated alpha's and beam ions injected for current profile control. We present a qualitative interpretation of these observations using an analytic model of the Doppler-shifted ion-cyclotron resonance drive responsible for GAE instability which has an important dependence on k(perpendicular to rho L). A quantitative analysis of this data with the HYM stability code predicts both the frequencies and instability of the GAE prior to, and suppression of the GAE after the injection of high pitch-angle beam ions.

  15. Treatment readiness, attitudes toward, and experiences with methadone and buprenorphine maintenance therapy among people who inject drugs in Malaysia

    Science.gov (United States)

    Vijay, Aishwarya; Bazazi, Alexander R.; Yee, Ilias; Kamarulzaman, Adeeba; Altice, Frederick L.

    2016-01-01

    Background Little is known about attitudes toward and experiences with opioid maintenance therapy (OMT) among people who inject drugs in Malaysia, a country where people who inject drugs comprise 1.3% of the adult population. Methods In 2010, 460 people who inject drugs in Greater Kuala Lumpur, Malaysia were surveyed to evaluate attitudes toward and experience with OMT and treatment readiness. Attitudes towards OMT with both methadone and buprenorphine were assessed using an opinions scale. Multivariable linear regression was used to assess correlates of treatment readiness, measured with the 19-item Stages of Change Readiness and Treatment Eagerness Scale (SOCRATES). Results All 460 participants used opioids and nearly all (99.1%) met criteria for opioid dependence. Few had had previous experience with methadone (9.3%) or buprenorphine (12.6%) maintenance therapy, yet many had used methadone (55.2%) or buprenorphine (51.7%) outside of treatment settings. Fifteen percent had injected buprenorphine in the past month, and of the few that were currently receiving buprenorphine maintenance therapy, almost all were injecting it. The majority of subjects exhibited a moderate level of treatment readiness and a preference for methadone over buprenorphine. Those with low treatment readiness scores were more likely to have previous experience with compulsory drug detention centers (p<0.01), needle/syringe exchange programs (p<0.005), or be of Indian ethnicity (p<0.001). Past use of methadone (p<0.01), older age (p<0.001), stress symptom severity (p<0.001), and sharing of needles or syringes (p<0.05) were associated with higher treatment readiness scores. Conclusion There are suboptimal levels of OMT experience among people who inject drugs that may be improved by addressing factors that influence patient attitudes. Those individuals with moderate treatment readiness may be targeted by brief motivational and cognitive interventions in primary care, prisons or OMT clinics

  16. The prevalence and risks of early childhood caries (ECC) in Toronto, Canada.

    Science.gov (United States)

    Al-Jewair, Thikriat S; Leake, James L

    2010-10-14

    To determine the prevalence and risks of early childhood caries (ECC) among children less than 71 months of age in Toronto, Canada, and to evaluate the association between parental/caregiver depression and ECC. A secondary analysis of data previously collected by the Toronto Public Health as part of the 2003 Toronto Perinatal and Child Health Survey was performed. The 90-item survey was conducted over the telephone to 1,000 families with children from zero years (birth) to six years of age. Parents/caregivers were asked about factors related to the development and health of their children. For this study, only children younger than six years of age (less than 71 months) were included (n=833). The primary outcome of interest was self-reported and measured by the response to the question of whether a physician/dentist had ever told the parent/caregiver his/her child had ECC. The prevalence of ECC was 4.7 percent (37 of 791 children). The child's age, his/her history of dental visits, teeth brushing, the use of fluoridated toothpaste, the parent's/caregiver's depressive tendencies, the language spoken at home, and the household annual income were all significant in the bivariate analysis. Multiple logistic regression identified four factors associated with ECC: the child's age (being three years of age or older), having at least one parent/caregiver with depression, not speaking English at home, and having an annual household income less than $40,000 in Canadian dollars (CAD). While a child's age, home language, and household income are known risks for ECC, the finding that parental/caregiver depression may be related to ECC is new. Multiple risk factors are involved in the development of early childhood caries. Of particular importance are demographic (e.g., child's age), social (e.g., annual household income), and psychosocial factors (e.g., parental/caregiver depression) that are indirectly linked to ECC. More attention needs to be placed on understanding the role

  17. Preliminary Evaluation Methodology of ECCS Performance for Design Basis LOCA Redefinition

    International Nuclear Information System (INIS)

    Kang, Dong Gu; Ahn, Seung Hoon; Seul, Kwang Won

    2010-01-01

    To improve their existing regulations, the USNRC has made efforts to develop the risk-informed and performance-based regulation (RIPBR) approaches. As a part of these efforts, the rule revision of 10CFR50.46 (ECCS Acceptance Criteria) is underway, considering some options for 4 categories of spectrum of break sizes, ECCS functional reliability, ECCS evaluation model, and ECCS acceptance criteria. Since the potential for safety benefits and unnecessary burden reduction from design basis LOCA redefinition is high relative to other options, the USNRC is proceeding with the rulemaking for design basis LOCA redefinition. An instantaneous break with a flow rate equivalent to a double ended guillotine break (DEGB) of the largest primary piping system in the plant is widely recognized as an extremely unlikely event, while redefinition of design basis LOCA can affect the existing regulatory practices and approaches. In this study, the status of the design basis LOCA redefinition and OECD/NEA SMAP (Safety Margin Action Plan) methodology are introduced. Preliminary evaluation methodology of ECCS performance for LOCA is developed and discussed for design basis LOCA redefinition

  18. Energy-dissipating and self-repairing SMA-ECC composite material system

    International Nuclear Information System (INIS)

    Li, Xiaopeng; Li, Mo; Song, Gangbing

    2015-01-01

    Structural component ductility and energy dissipation capacity are crucial factors for achieving reinforced concrete structures more resistant to dynamic loading such as earthquakes. Furthermore, limiting post-event residual damage and deformation allows for immediate re-operation or minimal repairs. These desirable characteristics for structural ‘resilience’, however, present significant challenges due to the brittle nature of concrete, its deformation incompatibility with ductile steel, and the plastic yielding of steel reinforcement. Here, we developed a new composite material system that integrates the unique ductile feature of engineered cementitious composites (ECC) with superelastic shape memory alloy (SMA). In contrast to steel reinforced concrete (RC) and SMA reinforced concrete (SMA-RC), the SMA-ECC beams studied in this research exhibited extraordinary energy dissipation capacity, minimal residual deformation, and full self-recovery of damage under cyclic flexural loading. We found that the tensile strain capacity of ECC, tailored up to 5.5% in this study, allows it to work compatibly with superelastic SMA. Furthermore, the distributed microcracking damage mechanism in ECC is critical for sufficient and reliable recovery of damage upon unloading. This research demonstrates the potential of SMA-ECC for improving resilience of concrete structures under extreme hazard events. (paper)

  19. Holistic care patient with Early Childhood Caries (ECC: A case report

    Directory of Open Access Journals (Sweden)

    Intan Maulani

    2016-06-01

    Full Text Available Early Childhood Caries (ECC is a specific form of severe dental caries that affects infants and young children. ECC progresses rapidly in those who are at high risk, and often goes untreated. Children experiencing caries as infants or toddlers have a much greater probability of subsequent caries in both primary and permanent dentitions. This case showed management holistic care for children with ECC.A five year old boy patient accompanied with her parents were reported to the Pedodontic Clinic Padjadjaran University Dental Hospital with a chief complaint of decayed upper anterior teeth and pain in the molar teeth. Clinical examinations found dental caries almost all teeth in the maxilla and mandible. Based on panoramic radiograph, treatments that can be done are strip crown glass ionomer restorations, pulp treatments, extractions and fixed space maintainer. Patients diagnosed with severe ECC, patient and parents described on this type of caries. During treatment the patient was given oral hygiene instruction and recommend daily use of tooth mouse. After all treatment were completed, fluoride topical, and fissure sealants, recall check up after three months was scheduled. Holistic care needed in handling children with ECC.

  20. Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

    Directory of Open Access Journals (Sweden)

    Li Yuquan

    2017-02-01

    Full Text Available The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA, the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the

  1. Comparative experiments to assess the effects of accumulator nitrogen injection on passive core cooling during small break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Li, YuQuan; Hao, Botao; Zhong, Jia; Wan Nam [State Nuclear Power Technology R and D Center, South Park, Beijing Future Science and Technology City, Beijing (China)

    2017-02-15

    The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME)—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative

  2. Preliminary three-dimensional potential flow simulation of a five-liter flask air injection experiment

    International Nuclear Information System (INIS)

    Davis, J.E.

    1977-01-01

    The preliminary results of an unsteady three-dimensional potential flow analysis of a five-liter flask air injection experiment (small-scale model simulation of a nuclear reactor steam condensation system) are presented. The location and velocity of the free water surface in the flask as a function of time are determined during pipe venting and bubble expansion processes. The analyses were performed using an extended version of the NASA-Ames Three-Dimensional Potential Flow Analysis System (POTFAN), which uses the vortex lattice singularity method of potential flow analysis. The pressure boundary condition at the free water surface and the boundary condition along the free jet boundary near the pipe exit were ignored for the purposes of the present study. The results of the analysis indicate that large time steps can be taken without significantly reducing the accuracy of the solutions and that the assumption of inviscid flow should not have an appreciable effect on the geometry and velocity of the free water surface. In addition, the computation time required for the solutions was well within acceptable limits

  3. Simulation of multi-pulse coaxial helicity injection in the Sustained Spheromak Physics Experiment

    Science.gov (United States)

    O'Bryan, J. B.; Romero-Talamás, C. A.; Woodruff, S.

    2018-03-01

    Nonlinear, numerical computation with the NIMROD code is used to explore magnetic self-organization during multi-pulse coaxial helicity injection in the Sustained Spheromak Physics eXperiment. We describe multiple distinct phases of spheromak evolution, starting from vacuum magnetic fields and the formation of the initial magnetic flux bubble through multiple refluxing pulses and the eventual onset of the column mode instability. Experimental and computational magnetic diagnostics agree on the onset of the column mode instability, which first occurs during the second refluxing pulse of the simulated discharge. Our computations also reproduce the injector voltage traces, despite only specifying the injector current and not explicitly modeling the external capacitor bank circuit. The computations demonstrate that global magnetic evolution is fairly robust to different transport models and, therefore, that a single fluid-temperature model is sufficient for a broader, qualitative assessment of spheromak performance. Although discharges with similar traces of normalized injector current produce similar global spheromak evolution, details of the current distribution during the column mode instability impact the relative degree of poloidal flux amplification and magnetic helicity content.

  4. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  5. Treatment readiness, attitudes toward, and experiences with methadone and buprenorphine maintenance therapy among people who inject drugs in Malaysia.

    Science.gov (United States)

    Vijay, Aishwarya; Bazazi, Alexander R; Yee, Ilias; Kamarulzaman, Adeeba; Altice, Frederick L

    2015-07-01

    Little is known about attitudes toward and experiences with opioid maintenance therapy (OMT) among people who inject drugs in Malaysia, a country where people who inject drugs comprise 1.3% of the adult population. In 2010, 460 people who inject drugs in Greater Kuala Lumpur, Malaysia were surveyed to evaluate attitudes toward and experiences with OMT and treatment readiness. Attitudes towards OMT with both methadone and buprenorphine were assessed using an opinions scale. Multivariable linear regression was used to assess correlates of treatment readiness, measured with the 19-item Stages of Change Readiness and Treatment Eagerness Scale (SOCRATES). All 460 participants used opioids and nearly all (99.1%) met criteria for opioid dependence. Few had had previous experience with methadone (9.3%) or buprenorphine (12.6%) maintenance therapy, yet many had used methadone (55.2%) or buprenorphine (51.7%) outside of treatment settings. Fifteen percent had injected buprenorphine in the past month, and of the few that were currently receiving buprenorphine maintenance therapy, almost all were injecting it. The majority of subjects exhibited a moderate level of treatment readiness and a preference for methadone over buprenorphine. Those with low treatment readiness scores were more likely to have previous experience with compulsory drug detention centers (polder age (ppeople who inject drugs that may be improved by addressing factors that influence patient attitudes. Those individuals with moderate treatment readiness may be targeted by brief motivational and cognitive interventions in primary care, prisons or OMT clinics aimed at improving entry into and retention in treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Experiences with policing among people who inject drugs in Bangkok, Thailand: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Kanna Hayashi

    2013-12-01

    Full Text Available Despite Thailand's commitment to treating people who use drugs as "patients" not "criminals," Thai authorities continue to emphasize criminal law enforcement for drug control. In 2003, Thailand's drug war received international criticism due to extensive human rights violations. However, few studies have since investigated the impact of policing on drug-using populations. Therefore, we sought to examine experiences with policing among people who inject drugs (PWID in Bangkok, Thailand, between 2008 and 2012.Between July 2011 and June 2012, semi-structured, in-depth interviews were conducted with 42 community-recruited PWID participating in the Mitsampan Community Research Project in Bangkok. Interviews explored PWID's encounters with police during the past three years. Audio-recorded interviews were transcribed verbatim, and a thematic analysis was conducted to document the character of PWID's experiences with police. Respondents indicated that policing activities had noticeably intensified since rapid urine toxicology screening became available to police. Respondents reported various forms of police misconduct, including false accusations, coercion of confessions, excessive use of force, and extortion of money. However, respondents were reluctant to report misconduct to the authorities in the face of social and structural barriers to seeking justice. Respondents' strategies to avoid police impeded access to health care and facilitated transitions towards the misuse of prescribed pharmaceuticals. The study's limitations relate to the transferability of the findings, including the potential biases associated with the small convenience sample.This study suggests that policing in Bangkok has involved injustices, human rights abuses, and corruption, and policing practices in this setting appeared to have increased PWID's vulnerability to poor health through various pathways. Novel to this study are findings pertaining to the use of urine drug

  7. Injection Methods and Instrumentation for Serial X-ray Free Electron Laser Experiments

    Science.gov (United States)

    James, Daniel

    Scientists have used X-rays to study biological molecules for nearly a century. Now with the X-ray free electron laser (XFEL), new methods have been developed to advance structural biology. These new methods include serial femtosecond crystallography, single particle imaging, solution scattering, and time resolved techniques. The XFEL is characterized by high intensity pulses, which are only about 50 femtoseconds in duration. The intensity allows for scattering from microscopic particles, while the short pulses offer a way to outrun radiation damage. XFELs are powerful enough to obliterate most samples in a single pulse. While this allows for a "diffract and destroy" methodology, it also requires instrumentation that can position microscopic particles into the X-ray beam (which may also be microscopic), continuously renew the sample after each pulse, and maintain sample viability during data collection. Typically these experiments have used liquid microjets to continuously renew sample. The high flow rate associated with liquid microjets requires large amounts of sample, most of which runs to waste between pulses. An injector designed to stream a viscous gel-like material called lipidic cubic phase (LCP) was developed to address this problem. LCP, commonly used as a growth medium for membrane protein crystals, lends itself to low flow rate jetting and so reduces the amount of sample wasted significantly. This work discusses sample delivery and injection for XFEL experiments. It reviews the liquid microjet method extensively, and presents the LCP injector as a novel device for serial crystallography, including detailed protocols for the LCP injector and anti-settler operation.

  8. Data report for ROSA-IV LSTF gravity-driven safety injection experiment run SB-CL-27

    International Nuclear Information System (INIS)

    Yonomoto, Taisuke; Saitou, Seishi; Kuroda, Takeshi

    1994-03-01

    Experimental data are presented for the passive injection test, Run SB-CL-27, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on September 17, 1992. This experiment simulated thermal-hydraulic behavior of a gravity-driven, passive safety injection system during a small-break loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). The injection system consisted of a gravity-driven injection tank, located above the reactor vessel, with connecting lines. The tank was initially filled with water of room temperature at the same pressure as the pressurizer. The connecting lines to the cold leg and to the vessel downcomer were opened at the test initiation. Then, a natural circulation flow developed in the loop which was formed by these lines and the injection tank. The hot water in the cold leg circulated into the upper part of tank and accumulated there causing a significant thermal stratification. This thermal stratification prevented direct-contact condensation of steam from occurring during the subsequent tank drain-down phase. Therefore, no condensation-induced depressurization of the tank, affecting adversely the injection performance, occurred. (author)

  9. Identification of temperature-dependent water quality changes during a deep well injection experiment in a pyritic aquifer

    NARCIS (Netherlands)

    Prommer, H.; Stuijfzand, P.J.

    2005-01-01

    Artificial recharge is a technique used increasingly to supplement drinking water supplies. To assess the potential water quality changes that occur during subsurface passage, a comprehensive deep-well injection experiment was carried out for a recharge scheme, where pretreated, aerobic surface

  10. Accomplishments of LOCA/ECCS experimental research at Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Tasaka, Kanji; Murao, Yoshio; Koizumi, Yasuo

    1984-01-01

    Japan Atomic Energy Research Institute has investigated loss-of-coolant accident (LOCA)/emergency core cooling system (ECCS) from 1970. Major results of the LOCA/ECCS research are summarized in this report. ROSA-II program was LOCA/ECCS research for a pressurized water reactor (PWR) and ROSA-III program was for a boiling water reactor (BWR). The both test facilities were scaled at approximately 1/400 of the respective reference PWR and BWR. Large scale reflood test is research on reflood phenomena during a large break LOCA of PWR. The test facility is scaled at approximately 1/20 of the reference PWR and the research is still being continued. (author)

  11. Lightweight ECC based RFID authentication integrated with an ID verifier transfer protocol.

    Science.gov (United States)

    He, Debiao; Kumar, Neeraj; Chilamkurti, Naveen; Lee, Jong-Hyouk

    2014-10-01

    The radio frequency identification (RFID) technology has been widely adopted and being deployed as a dominant identification technology in a health care domain such as medical information authentication, patient tracking, blood transfusion medicine, etc. With more and more stringent security and privacy requirements to RFID based authentication schemes, elliptic curve cryptography (ECC) based RFID authentication schemes have been proposed to meet the requirements. However, many recently published ECC based RFID authentication schemes have serious security weaknesses. In this paper, we propose a new ECC based RFID authentication integrated with an ID verifier transfer protocol that overcomes the weaknesses of the existing schemes. A comprehensive security analysis has been conducted to show strong security properties that are provided from the proposed authentication scheme. Moreover, the performance of the proposed authentication scheme is analyzed in terms of computational cost, communicational cost, and storage requirement.

  12. BREASTFEEDING AND EARLY CHILDHOOD CARIES (ECC SEVERITY OF CHILDREN UNDER THREE YEARS OLD IN DKI JAKARTA

    Directory of Open Access Journals (Sweden)

    Risqa Rina Darwita

    2008-12-01

    Full Text Available The prevalence and severity of caries in children under three years old are constantly increasing. One of the cause is the increase consumption of cariogenic carbohydrate. Breast milk have buffer capacity that eventually able to prevent caries. The aims of this research are to discover the correlation between breastfeeding with the severity of Early Childhood Caries (ECC in children under three years old, to provide information on prevalence and severity of caries in children under three years, and to explain factors influencing the incidence of ECC. This research designed cross sectionally and conducted upon 565 children aged 12-38 months, selected using multistage cluster random sampling. The ECC prevalence of children under three years in DKI Jakarta is 52.7%, with average score of def-t 2.85. Bivariate analysis showed that, variables which correlate with the level of ECC are; the way to deliver (p=0,012, frequency (p=0,002, duration (p=0,002, salivary buffer capacity (p=0.013, habitual consumption of sugary diet (p=0.005, child’s dental hygiene behavior (p=0.002, and mother’s education (p=0.001. Multivariate analysis showed that ECC can be explained by these variables: age, mother’s education, the way to deliver and frequency of breast milk complements/replacement of consumtions, child’s brushing habit, plaque pH, and salivary buffer capacity. Resulting determination coefficient 32.1%. There is no significant correlation between breastfeeding and the level of Early Childhood Caries (ECC. The role of protective qualities of breastfeeding are not shown because of bias in obtaining data influence the incidence of caries.

  13. Injection laryngoplasty using BIOPEX calcium phosphate cement. The Sanokousei General Hospital experience

    International Nuclear Information System (INIS)

    Okubo, Keisuke; Shinnabe, Akihiro; Saito, Koichiro; Shiotani, Akihiro

    2008-01-01

    The calcium phosphate bone paste BIOPEX is an injectable material developed as a bone replacement that hardens into a hydroxylapatite block after injection. BIOPEX offers many advantages as a material for injection laryngoplasty: it induces little foreign-material reaction, is minimally absorbed, and is easy to prepare in the OR. Between 2004 and 2007, 14 patients, including 13 with vocal fold paralysis and 1 with severe atrophy of the vocal folds, were treated with BIOPEX-injection laryngoplasty at Sanokousei General Hospital. The injection of BIOPEX is usually performed through a direct laryngoscopy under general anesthesia, and no adverse effects were observed in any of the cases. A postoperative three-dimensional CT revealed successful injection of the BIOPEX into the paraglottic space in all cases. BIOPEX is minimally absorbed over long time periods, and this procedure results in a dramatic improvement of glottic function immediately after surgery. We consider this operative technique, which aims at medialization of the vocal fold by injection of a sclerotic agent into the lateral side of the vocal fold, as 'type I thyroplasty from inside the laryngeal framework.' (author)

  14. HM modelling of in-situ gas injection tests in bentonite and argillite: the PGZ experiment

    International Nuclear Information System (INIS)

    Gerard, P.; Charlier, R.; Radu, J.P.; La Vaissiere, R. de; Talandier, J.; Collin, F.

    2010-01-01

    Document available in extended abstract form only. During long-term repository of high and intermediate level nuclear waste in deep argillaceous geological formation, steel containers will corroded and organic material will be irradiated. The two processes lead mostly to hydrogen production. This study deals with the numerical modelling of the gas migration in both the host formation and a bentonite plug, with an emphasis on coupling between the gas transfer and the mechanical strains and stresses. More particularly the study aims to support the design of the PGZ in situ experiment that will be performed by Andra in its underground laboratory at Bure. The objective of the experiment is the analysis of the dynamics of the bentonite plug re-saturation, studying the competition between the liquid water coming from the argillite and a gas injection. The modelled experiment consists of a borehole drilled in rock clay, inside which a plug of MX-80 bentonite is set. The bentonite is naturally re-saturated by water coming from the host formation. At the same time a gas pressure, higher than the initial water pressure in the host rock, is imposed at both ends of the plug. The developed model takes into account the coupling between the mechanical behaviour and the water and gas transfers in undisturbed geo-materials. It manages explicitly liquid and vapour water, gaseous and dissolved hydrogen. Elastoplastic and non-linear elastic model are used to model the behaviour of, respectively, the argillaceous rock and the bentonite. The numerical results show the small desaturation obtained in bentonite and argillite. The influence of the coupling of the mechanic on the water and gas transfers is thus limited (due to the Bishop's effective stress). The swelling of the bentonite plug is not hindered by the gas migration and the confining effect of the engineered barrier is maintained. An analysis is made of the influence of the main transfer rock properties on the gas pressure

  15. The U.S. Gas Flooding Experience: CO2 Injection Strategies and Impact on Ultimate Recovery

    Energy Technology Data Exchange (ETDEWEB)

    Nunez-Lopez, Vanessa [The University of Texas at Austin; Hosseini, Seyyed; Gil-Egui, Ramon

    2017-09-29

    The Permian Basin in West Texas and southwestern New Mexico has seen 45 years of oil reserve growth through CO2 enhanced oil recovery (CO2 EOR). More than 60 CO2 EOR projects are currently active in the region’s limestone, sandstone and dolomite reservoirs. Water alternating gas (WAG) has been the development strategy of choice in the Permian for several technical and economic reasons. More recently, the technology started to get implemented in the much more porous and permeable clastic depositional systems of the onshore U.S. Gulf Coast. Continued CO2 injection (CGI), as opposed to WAG, was selected as the injection strategy to develop Gulf Coast oil fields, where CO2 injection volumes are significantly larger (up to 6 times larger) than those of the Permian. We conducted a compositional simulation based study with the objective of comparing the CO2 utilization ratios (volume of CO2 injected to produce a barrel of oil) of 4 conventional and novel CO2 injection strategies: (1) continuous gas injection (CGI), (2) water alternating gas (WAG), (3) water curtain injection (WCI), and (4) WAG and WCI combination. These injection scenarios were simulated using the GEM module from the Computer Modeling Group (CMG). GEM is an advanced general equation-of-state compositional simulator, which includes equation of state, CO2 miscible flood, CO2/brine interactions, and complex phase behavior. The simulator is set up to model three fluid phases including water, oil, and gas. Our study demonstrates how the selected field development strategy has a significant impact on the ultimate recovery of CO2-EOR projects, with GCI injection providing maximum oil recovery in absolute volume terms, but with WAG offering a more balanced technical-economical approach.

  16. CFD Analysis of the Safety Injection Tank and Fluidic Device

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Nietiadi, Yohanes Setiawan; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Addad, Yacine [KUSTAR, Abu Dhabi (United Arab Emirates)

    2016-05-15

    One of the most important components in the ECCS is the safety injection tank (SIT). Inside the SIT, a fluidic device is installed, which passively controls the mass flow of the safety injection and eliminates the need for low pressure safety injection pumps. As more passive safety mechanisms are being pursued, it has become more important to understand flow structure and the loss mechanism within the fluidic device. Current computational fluid dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study proposes to find a more exact result using CFD and more realistic modeling to predict the performance during accident scenarios more accurately. The safety injection tank with fluidic device was analyzed thoroughly using CFD. The preliminary calculation used 60,000 meshes for the initial test calculation. The results fit the experimental results surprisingly despite its coarse grid. Nonetheless, the mesh resolution was increased to capture the vortex in the fluidic device precisely. Once a detailed CFD computation is finished, a small-scale experiment will be conducted for the given conditions. Using the experimental results and the CFD model, physical models can be improved to fit the results more accurately.

  17. Optimization experiment of gas oil direct injection valve for CNG dual fuel diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.Y. [Chonnam National University Graduate School, Jeonju (Korea); Park, C. K. [Chonnam National University, Jeonju (Korea)

    1999-04-01

    In this study, we studied for a conversion from diesel engine to natural gas dual fuel engine. For this experimental, we tested about the injection quantity characteristics of pilot valve with the plunger diameter at the retraction volume and investigated to the engine performance and exhaust emissions with the nozzle hole number and injection nozzle diameter. As a result, when the plunger diameter is 7.5 mm at the retraction volume, 25 mm{sup 3}/st, the injection quantity characteristics develop. Also, when a nozzle type is 4*{phi} 0.24, total hydrocarbon(THC) emission reduce at low equivalence ratio. (author). 5 refs., 10 figs., 2 tabs.

  18. Is 300 Seconds ACT Safe and Efficient during MiECC Procedures?

    Science.gov (United States)

    Bauer, Adrian; Hausmann, Harald; Schaarschmidt, Jan; Szlapka, Michal; Scharpenberg, Martin; Eberle, Thomas; Hasenkam, J Michael

    2017-12-31

     The recommended minimum activated clotting time (ACT) level for cardiopulmonary bypass (CPB) of 480 seconds originated from investigations with bubble oxygenators and uncoated extracorporeal circulation (ECC) systems. Modern minimal invasive ECC (MiECC) systems are completely closed circuits containing a membrane oxygenator and a tip-to-tip surface coating. We hypothesized that surface coating and the "closed-loop" design allow the MiECC to safely run with lower ACT levels and that an ACT level of 300 seconds can be safely applied without thromboembolic complications. The aim of this study was to investigate the potential risks during application of reduced heparin levels in patients undergoing coronary surgery.  In this study, 68 patients undergoing coronary artery bypass grafting with MiECC were randomized to either the study group with an ACT target of 300 seconds or the control group with an ACT of 450 seconds. All other factors of MiECC remained unchanged.  The study group received significantly less heparin and protamine (heparin [international units] median [min-max], Red_AC: 32,800 [23,000-51,500] vs. Full_AC: 50,000 [35,000-65,000] p  ACT in the study group was significantly lower at the start of MiECC (mean ± standard deviation: study group 400 ± 112 vs. control group 633 ± 177; p  ACT levels were: study group 344 ± 60 versus control group 506 ± 80. In both groups, the values of the endogenous thrombin potential (ETP) decreased simultaneously. None of the study participants experienced thromboembolic complications.  Since no evidence of increased thrombin formation (ETP) was found from a laboratory standpoint, we concluded that the use of MiECC with a reduced anticoagulation strategy seems possible. This alternative anticoagulation strategy leads to significant reduction in dosages of both heparin and protamine. We can confidently move forward with investigating this anticoagulation concept. However, to

  19. A PWR reactor downcomer modification for reduction of ECC bypass flow during LOCA

    International Nuclear Information System (INIS)

    Popov, N.; Bosevski, T.

    1986-01-01

    The ECC bypass phenomenon in the PWR reactor down-comer, which delays the reactor vessel refilling, after cold leg large break LOCA accident, has been subject of analysis in this paper. In the paper, a particular construction modification of the reactor down-comer has been suggested by inserting vertical ribs, aimed to intensify the reactor ECC refilling following the LOCA accident, and to advance the thermal-hydraulics safety of post-accidental cooling of the PWR reactors. To verify the effectiveness of the suggested down-comer construction modification, some properly selected results, obtained by corresponding verified mathematical model, have been presented in this paper. (author)

  20. Syringe vending machines for injection drug users: an experiment in Marseille, France.

    Science.gov (United States)

    Obadia, Y; Feroni, I; Perrin, V; Vlahov, D; Moatti, J P

    1999-01-01

    OBJECTIVES: This study evaluated the usefulness of vending machines in providing injection drug users with access to sterile syringes in Marseille, France. METHODS: Self-administered questionnaires were offered to 485 injection drug users obtaining syringes from 32 pharmacies, 4 needle exchange programs, and 3 vending machines. RESULTS: Of the 343 respondents (response rate = 70.7%), 21.3% used the vending machines as their primary source of syringes. Primary users of vending machines were more likely than primary users of other sources to be younger than 30 years, to report no history of drug maintenance treatment, and to report no sharing of needles or injection paraphernalia. CONCLUSIONS: Vending machines may be an appropriate strategy for providing access to syringes for younger injection drug users, who have typically avoided needle exchange programs and pharmacies. PMID:10589315

  1. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  2. Cooling water injection system

    International Nuclear Information System (INIS)

    Inai, Nobuhiko.

    1989-01-01

    In a BWR type reactor, ECCS system is constituted as a so-called stand-by system which is not used during usual operation and there is a significant discontinuity in relation with the usual system. It is extremely important that ECCS operates upon occurrence of accidents just as specified. In view of the above in the present invention, the stand-by system is disposed along the same line with the usual system. That is, a driving water supply pump for supplying driving water to a jet pump is driven by a driving mechanism. The driving mechanism drives continuously the driving water supply pump in a case if an expected accident such as loss of the function of the water supply pump, as well as during normal operation. That is, all of the water supply pump, jet pump, driving water supply pump and driving mechanism therefor are caused to operate also during normal operation. The operation of them are not initiated upon accident. Thus, the cooling water injection system can perform at high reliability to remarkably improve the plant safety. (K.M.)

  3. ECCS analysis of B and W's 177-FA lowered-loop NSS

    International Nuclear Information System (INIS)

    Jones, R.C.; Biller, J.R.; Dunn, B.M.

    1975-06-01

    The effectiveness for the ECCS for B and W's 177-FA Lowered-Loop NSS is shown to meet the five criteria of 10 CFR 50.46. A spectrum analysis is performed and the worst case is used to establish allowable linear heat rates as a function of elevation in the core. (U.S.)

  4. MICROORGANISMS FOUND IN SECONDARY CATARACT MATERIAL OF ECCE PATIENTS, A STUDY WITH SEM AND TEM

    NARCIS (Netherlands)

    KALICHARAN, D; JONGEBLOED, WL; LOS, LI; WORST, JGF

    1993-01-01

    Globular secondary cataract material, removed from 24 patients with ECCE after ophthalmic cleaning of the anterior capsule, were investigated with SEM and TEM. Besides spherical, somewhat oval shaped bodies of various shape and size comparable with those found in cataractous lenses, (an)aerobic

  5. Complete genome sequences of Escherichia coli strains 1303 and ECC-1470 isolated from bovine mastitis

    NARCIS (Netherlands)

    Leimbach, Andreas; Poehlein, Anja; Witten, Anika; Scheutz, Flemming; Schukken, Ynte|info:eu-repo/dai/nl/075051907; Daniel, Rolf; Dobrindt, Ulrich

    2016-01-01

    Escherichia coli is the leading causative agent of acute bovine mastitis. Here, we report the complete genome sequence of E. coli O70:H32 strain 1303, isolated from an acute case of bovine mastitis, and E. coli Ont:Hnt strain ECC-1470, isolated from a persistent infection.

  6. Evaluation of the long duration efficiency of the ECC storage facility of Cogema La Hague plant

    International Nuclear Information System (INIS)

    Baganz, C.; Bouland, P.; Breton, E.

    2004-01-01

    The ECC facility of Cogema La Hague has been designed in view of the storage of 24000 CSD-C type containers produced by the ACC facility. It comprises a reception and unloading unit, and a modular storage unit (alveoles). The safety of the facility is based on: a controlled ventilation (low pressurization rooms, controlled atmosphere, heat and toxic gases evacuation), a construction ensuring the static confinement, the sub-criticality and the radiological protection, and the possibility of natural ventilation of the alveoles (earthquake-dimensioned equipments). On the basis of these safety functions, the conformability of the facility with respect to long duration has been analyzed considering three aspects of the facility: the infrastructure, the waste packages and the ventilation system. In normal operation, a foreseeable service life of at least 100 years is established: simpleness and accessibility of ventilation systems, no significant corrosion of packages, durability of the reinforced concrete structure. The demonstration of a service life greater than 100 years would require the improvement of our knowledge about concretes in terms of experience feedback. The behaviour of the facility in terms of loss of technical mastery has been considered too. The scenario retained for this situation is the prolonged stoppage (several months or years) of the nuclear ventilation after a 100 years of disposal. After this period of time, both the thermal power and the hydrogen generation from waste packages will have significantly diminished, allowing a loss of technical mastery era of several years with no impact on concretes integrity. However, during long situations of non-controlled atmosphere, the corrosion behaviour of stainless steels is not predictable. (J.S.)

  7. First observations of acceleration of injected electrons in a laser plasma beatwave experiment

    International Nuclear Information System (INIS)

    Ebrahim, N.A.; Martin, F.; Bordeur, P.; Heighway, E.A.; Matte, J.P.; Pepin, H.; Lavigne, P.

    1986-01-01

    The first experimental observations of acceleration of injected electrons in a laser driven plasma beatwave are presented. The plasma waves were excited in an ionized gas jet, using a short pulse high intensity CO 2 laser with two collinearly propagating beams (at λ = 9.6 μm and 10.6 μm) to excite a fast wave (v/sub p/ = c). The source of electrons was a laser plasma produced on an aluminum slab target by a third, synchronized CO 2 laser beam. A double-focusing dipole magnet was used to energy select and inject electrons into the beatwave, and a second magnetic spectrograph was used to analyze the accelerated electrons. Electron acceleration was only observed when the appropriate resonant plasma density was produced (∼ 10 17 cm -3 ), the two laser lines were incident on the plasma, and electrons were injected into this plasma from an external source

  8. Phase III clinical evaluation of gadoteridol injection: Experience in pediatric neuro-oncologic MR imaging

    International Nuclear Information System (INIS)

    Debatin, J.F.; Nadel, S.N.; Gray, L.; Trotter, P.; Friedman, H.S.; Hockenberger, B.; Oakes, W.J.

    1992-01-01

    Twenty-two pediatric patients with known CNS neoplasms underwent magnetic resonance (MR) imaging before and after intravenous injection of 0.1 mmol/kg gadoteridol injection as part of a Phase IIIB open label multicenter clinical trial. Intravenous adminstration of this neutral, nonionic contrast agent was found to be safe in children. No clinically relevant changes in vital signs or laboratory values were attributed to the administration of gadoteridol injection. There were no systemic complaints. The imaging characteristics of gadoteridol in pediatric CNS disease appeared similar to those of gadopentetate dimeglumine. The very low toxicity, inherent to this nonionic low osmolal paramagnetic contrast formulation may allow administration of increased doses at increased infusion rates for an increased number of indications with improved sensitivity. (orig.)

  9. Animal experiment and clinical preliminary application of percutaneous 70% ethanol injection therapy in multi-drug resistant pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Liu Fuquan; Yue Zhendong; Gao Shunyu; Li YanSheng; Wei Guobin; Guo Weiyi; Chen Xijun; Li Baoyu

    2004-01-01

    Objective: To evaluate the clinical value of percutaneous injection of 70% ethanol in the treatment of multidrug resistant pulmonary tuberculosis. Methods: Percutaneous and transcatheter absolute ethanol, 70% ethanol, and 60% meglucamine diatrizoate(or distilled water) injection into the lung (25 cases) and the bronchi (25 cases) of healthy rabbits were performed, respectively.All specimens were studied with pathology. On the base of animals experiment, thirty-five patients with multi-drug resistant pulmonary tuberculosis were treated with percutaneous 70% ethanol injection. Every patient was treated by the same way for 1-3 times. Results: Pathological findings of the specimens of pulmonary tissue showed nonspecific inflammation, necrosis, and fibrosis. The chief pathological changes with percutaneous or transcatheter 70% ethanol injection were slighter than those with absolute ethanol injection. Pathological findings of the specimens of bronchi showed slight mucosal edema, nonspecific inflammation, and focal cytonecrosis. Recovery of the damaged bronchial mucosa occurred within 14-30 days after the treatment. All patients with multi-drug resistant pulmonary tuberculosis were followed up for 6 to 33 months. The sputum bacterial conversion to negative rate was 100% within 6 months after the treatment. Cavity closing, shrinking, and no changing rate were 47.1% (16/34), 50.0% (17/34), and 2.9% (1/34), respectively. Radiographic improvement rate was 94.3 % (33/35). No severe complications and adverse reactions occurred. Conclusion: Percutaneous 70% ethanol injection is safe, effective, and easy to perform in the treatment of multi-drug resistant pulmonary tuberculosis. (authors)

  10. Preparation and evaluation of 68Ga-ECC as a PET renal imaging agent

    International Nuclear Information System (INIS)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro; Geramifar, Patham; Beiki, Davood

    2015-01-01

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop 68 Ga-ethylenecysteamine cysteine ( 68 Ga-ECC). Ga-ECC was prepared using generator-based 68 GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). 68 Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV max ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous 99m Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time

  11. Preparation and evaluation of {sup 68}Ga-ECC as a PET renal imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Mizaei, Alireza; Jaililan, Amir Reza; Mazidi, Mohammad; Aghanejad, Ayuob; Yousefnia, Hassan; Shabani, Gholamli; Ardaneh, Khosro [Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Geramifar, Patham; Beiki, Davood [Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-09-15

    Development of a gallium-68-labeled renal tracer can be a good substitute for Tc-99m, a known SPECT tracer. In this study, effort was made to develop {sup 68}Ga-ethylenecysteamine cysteine ({sup 68}Ga-ECC). Ga-ECC was prepared using generator-based {sup 68}GaCl3 and ethylenecysteamine cysteine (ECC) at optimized conditions. Stability of the complex was checked in human serum followed by partition coefficient determination of the tracer. The biodistribution of the tracer in rats was studied using tissue counting and PET/CT imaging up to 120 min. Ga-ECC was prepared at optimized conditions in 15 min at 90 °C (radiochemical purity ≈97 ± 0.88 % ITLC, >99 % HPLC, specific activity: 210 ± 5 GBq/mM). {sup 68}Ga-ECC was a water-soluble complex based on partition coefficient data (log P; −1.378) and was stable in the presence of human serum for 2 h at 37 °C. The biodistribution of the tracer demonstrated high kidney excretion of the tracer in 10–20 min. The SUV{sub max} ratios of the liver to left kidney were 0.38 and 0.39 for 30 and 90 min, respectively, indicating high kidney uptake. Initial biodistribution results showed significant kidney and urinary excretion of the tracer comparable to that of the homologous {sup 99m}Tc compound. The complex could be a possible PET kidney imaging agent with a fast imaging time.

  12. A study on design of the trip computer for ECCS based on dynamic safety system

    International Nuclear Information System (INIS)

    Kim, Seog Nam

    2000-02-01

    The Emergency Core Cooling system in current nuclear power plants typically has a considerable number of complex functions and largely cumbersome operator interfaces. Functions for initiation, switch-over between various phases of operation, interlocks, monitoring, and alarming are usually performed by relay and analog comparator logic which is difficult to maintain and test. To improve problems of an analog based ECC (Emergency Core Cooling) System, the trip computer for ECCS based on Dynamic Safety System is implemented. The Dynamic Safety System (DSS) is a computer based reactor protection system that has fail-safe nature and performs a dynamic self-testing. The most important feature of the DSS is the introduction of test signal that send the system into a tripped state. The test signals are interleaved between the plant signals to produce an output which switches between a tripped and health state. The dynamic operation is a key feature of the failsafe design of the system. In this thesis, a possible implementation of the DSS using PLC is presented for a CANDU reactor. ECC System of the CANDU Reactor is selected as the reference system. The function of the DSS is implemented In PLC with the CONCEPT language. CONCEPT was developed by GROUPE SCHNEIDER as a graphic user interface programming tool for the Quantum PLC. A MMI display for ECCS based on DSS is implemented with LOOKOUT as an object driven programming tool. The Validation test has been performed by S/W Input Simulator as per Validation Test Procedure. The result of the test was checked and displayed on the MMI display. From the test results, it is shown that the DSS based ECC System operates correctly in all conditions

  13. Micro Engineering: Experiments conducted on the use of polymeric materials in micro injection moulding

    DEFF Research Database (Denmark)

    Griffiths, Christian; Tosello, Guido; Nestler, Joerg

    2008-01-01

    To advance micro injection moulding it is necessary to study systematically the factors affecting process and tooling reliability. This paper reviews the main findings of Cardiff Universities 4M and SEMOFS research in this field. In particular, the factors affecting the manufacturability of micro...

  14. Study on the impurity transport in the experiments on macroparticle injection into the FT-1 Tokamak

    International Nuclear Information System (INIS)

    Zhilinskij, A.P.; Kuteev, B.V.; Larionov, M.M.; Lebedev, A.D.; Mikhajkin, S.S.; Nikiforov, V.A.; Rozhanskij, V.A.; Tsendin, L.D.

    1980-01-01

    Studied is decomposition of the impurity disturbance (Li, C, O, Si, Ti, stainless steel, Cu, Mo, W) injected by a macroparticle into the central plasma region. It is shown that the impurity are carried out from the discharge at a tau characteristic time weakly depending on their sort. The tau values are in good agreement with the theoretical predictions accounting for the poloidal plasma rotation

  15. First experience with carbon stripping foils for the 160 MeV H- injection into the CERN PSB

    Science.gov (United States)

    Weterings, Wim; Bracco, Chiara; Jorat, Louise; Noulibos, Remy; van Trappen, Pieter

    2018-05-01

    160 MeV H- beam will be delivered from the new CERN linear accelerator (Linac4) to the Proton Synchrotron Booster (PSB), using a H- charge-exchange injection system. A 200 µg/cm2 carbon stripping foil will convert H- into protons by stripping off the electrons. The H- charge-exchange injection principle will be used for the first time in the CERN accelerator complex and involves many challenges. In order to gain experience with the foil changing mechanism and the very fragile foils, in 2016, prior to the installation in the PSB, a stripping foil test stand has been installed in the Linac4 transfer line. In addition, parts of the future PSB injection equipment are also temporarily installed in the Linac4 transfer line for tests with a 160 MeV H- commissioning proton beam. This paper describes the foil changing mechanism and control system, summarizes the practical experience of gluing and handling these foils and reports on the first results with beam.

  16. Experiments on the injection, confinement, and ejection of electron clouds in a magnetic mirror

    International Nuclear Information System (INIS)

    Eckhouse, S.; Fisher, A.; Rostoker, N.

    1978-01-01

    A cloud of (5 to 10 keV) electrons is injected into a magnetic mirror field. The magnetic field rises in 40--120 μsec to a maximum of 10 kG. Two methods of injection were tried: In the first, the injector is located at the mirror midplane and electrons are injected perpendicular to the magnetic field lines. In the second scheme, the injector is located near the mirror maximum. Up to about 10 11 electrons were trapped in both schemes with a mean kinetic energy of 0.3 MeV. Measured confinement time is limited only by the magnetic field decay time. The compressed electron cloud executes electrostatic oscillations. The frequency of the oscillation is proportional to the number of electrons trapped, and it is independent of the value of the magnetic field and the initial electron energy. The electron cloud was ejected along the mirror axis and properties of the ejected electron cloud were measured by x-ray pulses from bremstrahlung of electrons on the vacuum system wall and by collecting electrons on a Faraday cup

  17. Tokamak experiments on JIPP T-II with pulsed gas injection

    International Nuclear Information System (INIS)

    Toi, K.; Itoh, S.; Fujita, J.; Kadota, K.; Kawahata, K.

    1978-02-01

    The confinement of tokamak plasma has been investigated in the wide range of electron density average n sub(e) from 1 x 10 13 to 5 x 10 13 cm -3 by using the pulsed gas injection. The gross energy confinement time increases with increase of electron density and reaches 14 msec. The averaged effective ionic charge derived from plasma conductivity = is about 1 to 2 in the regime of small streaming parameter ( = 0.01 -- 0.08). The ratio of ion temperature to electron one is in the range greater than 0.5. This fact means that the ion energy confinement time is greater than the electron-ion energy relaxation time. Excessive injection of cold neutral gas excites m = 2 MHD oscillations. Much more gas injection leads to the remarkable cooling of plasma periphery and disruptive instabilities. These MHD oscillations and disruptive instabilities have been suppressed by the heating of plasma periphery with the second rapid rise of plasma current. (auth.)

  18. Road Maintenance Experience Using Polyurethane (PU) Foam Injection System and Geocrete Soil Stabilization as Ground Rehabilitation

    Science.gov (United States)

    Fakhar, A. M. M.; Asmaniza, A.

    2016-07-01

    There are many types of ground rehabilation and improvement that can be consider and implement in engineering construction works for soil improvement in order to prevent road profile deformation in later stage. However, when comes to road maintenance especially on operated expressways, not all method can be apply directly as it must comply to opreation's working window and lane closure basis. Key factors that considering ideal proposal for ground rehabilitation are time, cost, quality and most importantly practicality. It should provide long lifespan structure in order to reduce continuous cycle of maintenance. Thus, this paper will present two approaches for ground rehabilitation, namely Polyurethane (PU) Foam Injection System and Geocrete Soil Stabilization. The first approach is an injection system which consists two-parts chemical grout of Isocynate and Polyol when mixed together within soil structure through injection will polymerized with volume expansion. The strong expansion of grouting causes significant compression and compacting of the surrounding soil and subsequently improve ground properties and uplift sunken structure. The later is a cold in-place recyclying whereby mixture process that combines in-situ soil materials, cement, white powder (alkaline) additive and water to produce hard yet flexible and durable ground layer that act as solid foundation with improved bearing capacity. The improvement of the mechanical behaviour of soil through these two systems is investigated by an extensive testing programme which includes in-situ and laboratory test in determining properties such as strength, stiffness, compressibility, bearing capacity, differential settlement and etc.

  19. Impact of CO2 injection protocol on fluid-solid reactivity: high-pressure and temperature microfluidic experiments in limestone

    Science.gov (United States)

    Jimenez-Martinez, Joaquin; Porter, Mark; Carey, James; Guthrie, George; Viswanathan, Hari

    2017-04-01

    Geological sequestration of CO2 has been proposed in the last decades as a technology to reduce greenhouse gas emissions to the atmosphere and mitigate the global climate change. However, some questions such as the impact of the protocol of CO2 injection on the fluid-solid reactivity remain open. In our experiments, two different protocols of injection are compared at the same conditions (8.4 MPa and 45 C, and constant flow rate 0.06 ml/min): i) single phase injection, i.e., CO2-saturated brine; and ii) simultaneous injection of CO2-saturated brine and scCO2. For that purpose, we combine a unique high-pressure/temperature microfluidics experimental system, which allows reproducing geological reservoir conditions in geo-material substrates (i.e., limestone, Cisco Formation, Texas, US) and high resolution optical profilometry. Single and multiphase flow through etched fracture networks were optically recorded with a microscope, while processes of dissolution-precipitation in the etched channels were quantified by comparison of the initial and final topology of the limestone micromodels. Changes in hydraulic conductivity were quantified from pressure difference along the micromodel. The simultaneous injection of CO2-saturated brine and scCO2, reduced the brine-limestone contact area and also created a highly heterogeneous velocity field (i.e., low velocities regions or stagnation zones, and high velocity regions or preferential paths), reducing rock dissolution and enhancing calcite precipitation. The results illustrate the contrasting effects of single and multiphase flow on chemical reactivity and suggest that multiphase flow by isolating parts of the flow system can enhance CO2 mineralization.

  20. Injection of Compressed Diced Cartilage in the Correction of Secondary and Primary Rhinoplasty: A New Technique with 12 Years' Experience.

    Science.gov (United States)

    Erol, O Onur

    2017-11-01

    There are instances where small or large pockets are filled with diced cartilage in the nose, without use of wrapping materials. For this purpose, 1-cc commercial syringes were used. The obtained results were partial and incomplete. For better and improved results, the author designed new syringes, with two different sizes, which compress the diced cartilage for injection. The author presents his experience accrued over the past 12 years with 2366 primary, 749 secondary, 67 cleft lip and nose, and a total of 3182 rhinoplasties, using his new syringe design, which compresses diced cartilage and injects the diced cartilages as a conglutinate mass, simulating carved costal cartilage, but a malleable one. In 3125 patients, the take of cartilage graft was complete (98.2 percent) and a smooth surface was obtained, giving them a natural appearance. In 21 patients (0.65 percent), there was partial resorption of cartilage. Correction was performed with touch-up surgery by reinjection of a small amount of diced cartilage. In 36 patients (1.13 percent), there was overcorrection that, 1 year later, was treated by simple rasping. Compared with diced cartilage wrapped with Surgicel or fascia, the amount of injected cartilage graft is predictable because it consists purely of cartilage. The injected diced cartilage, because it is compressed and becomes a conglutinated mass, resembles a wood chip and simulates carved cartilage. It is superior to carved cartilage in that it is moldable, time saving, and gives a good result with no late show or warping. The injection takes only a few minutes.

  1. Monitoring a pilot CO2 injection experiment in a shallow aquifer using 3D cross-well electrical resistance tomography

    Science.gov (United States)

    Yang, X.; Lassen, R. N.; Looms, M. C.; Jensen, K. H.

    2014-12-01

    Three dimensional electrical resistance tomography (ERT) was used to monitor a pilot CO2 injection experiment at Vrøgum, Denmark. The purpose was to evaluate the effectiveness of the ERT method for monitoring the two opposing effects from gas-phase and dissolved CO2 in a shallow unconfined siliciclastic aquifer. Dissolved CO2 increases water electrical conductivity (EC) while gas phase CO2 reduce EC. We injected 45kg of CO2 into a shallow aquifer for 48 hours. ERT data were collected for 50 hours following CO2 injection. Four ERT monitoring boreholes were installed on a 5m by 5m square grid and each borehole had 24 electrodes at 0.5 m electrode spacing at depths from 1.5 m to 13 m. ERT data were inverted using a difference inversion algorithm for bulk EC. 3D ERT successfully detected the CO2 plume distribution and growth in the shallow aquifer. We found that the changes of bulk EC were dominantly positive following CO2 injection, indicating that the effect of dissolved CO2 overwhelmed that of gas phase CO2. The pre-injection baseline resistivity model clearly showed a three-layer structure of the site. The electrically more conductive glacial sand layer in the northeast region are likely more permeable than the overburden and underburden and CO2 plumes were actually confined in this layer. Temporal bulk EC increase from ERT agreed well with water EC and cross-borehole ground penetrating radar data. ERT monitoring offers a competitive advantage over water sampling and GPR methods because it provides 3D high-resolution temporal tomographic images of CO2 distribution and it can also be automated for unattended operation. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344. Lawrence Livermore National Security, LLC. LLNL IM release#: LLNL-PROC-657944.

  2. Ecce Homo: Science and Society Need Anthropological Collections.

    Science.gov (United States)

    Sholts, Sabrina B; Bell, Joshua A; Rick, Torben C

    2016-08-01

    Scientific collections are crucial to understanding the biological and cultural diversity of the Earth. Anthropological collections document the human experience and the interactions between people, ecosystems, and organisms. Unfortunately, anthropological collections are often poorly known by the public and face a variety of threats to their permanent care and conservation. Published by Elsevier Ltd.

  3. Early Childhood Care and Education (ECCE) in Ethiopia ...

    African Journals Online (AJOL)

    Early childhood care and education has been for many years in Ethiopia. However, these experiences were not systematized, reflected up on and, hence, efforts were not made to extract lessons and delineate future directions. This paper has made a modest attempt to bring to light developments registered, gaps noted and ...

  4. Lithium pellet injection experiments on the Alcator C-Mod tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Garnier, Darren Thomas [Univ. of California, Berkeley, CA (United States)

    1996-06-01

    A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient (ℓp ℓ a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li+ emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = ∞ and the n = 1 marginal stability limits.

  5. Lithium pellet injection experiments on the Alcator C-Mod tokamak

    International Nuclear Information System (INIS)

    Garnier, D.T.

    1996-06-01

    A pellet enhanced performance mode, showing significantly reduced core transport, is regularly obtained after the injection of deeply penetrating lithium pellets into Alcator C-Mod discharges. These transient modes, which typically persist about two energy confinement times, are characterized by a steep pressure gradient (ell p ≤ a/5) in the inner third of the plasma, indicating the presence of an internal transport barrier. Inside this barrier, particle and energy diffusivities are greatly reduced, with ion thermal diffusivity dropping to near neoclassical values. Meanwhile, the global energy confinement time shows a 30% improvement over ITER89-P L-mode scaling. The addition of ICRF auxiliary heating shortly after the pellet injection leads to high fusion reactivity with neutron rates enhanced by an order of magnitude over L-mode discharges with similar input powers. A diagnostic system for measuring equilibrium current density profiles of tokamak plasmas, employing high speed lithium pellets, is also presented. Because ions are confined to move along field lines, imaging the Li + emission from the toroidally extended pellet ablation cloud gives the direction of the magnetic field. To convert from temporal to radial measurements, the 3-D trajectory of the pellet is determined using a stereoscopic tracking system. These measurements, along with external magnetic measurements, are used to solve the Grad-Shafranov equation for the magnetic equilibrium of the plasma. This diagnostic is used to determine the current density profile of PEP modes by injection of a second pellet during the period of good confinement. This measurement indicates that a region of reversed magnetic shear exists at the plasma core. This current density profile is consistent with TRANSP calculations for the bootstrap current created by the pressure gradient. MHD stability analysis indicates that these plasmas are near the n = ∞ and the n = 1 marginal stability limits

  6. Russian experience with injectable chondroitin sulfate and glucosamine sulfate: a review of clinical trials

    Directory of Open Access Journals (Sweden)

    A. E. Karateev

    2018-01-01

    Full Text Available The widespread use of parenteral chondroprotectors is a feature of Russian medical practice. There are many drugs of this series in a Russian physician's arsenal, including chondroitin sulfate (CS,  glucosamine sulfate (GS, glycosaminoglycan-peptide complex, and  bioactive concentrate from small sea fish for intramuscular  injections. The paper analyzes Russian trials of the efficacy and  safety of two injectable formulations of CS and GS (ICS and IGS.  ICS was tested in 17 articles containing a total of 1639 patients with  osteoarthritis (OA, non-specific back pain (NBP, or shoulder  fractures and pain after stroke. Standard therapy (NSAIDs +  physiotherapy served as a control in the majority of the paper. In  these trials, the reductions in visual analog scale (VAS and WOMAC pain in OA treated with ICS averaged 58.2±22.3% and those were 26.1±14.7% in the control groups; the reductions in VAS NBP  reached an average of 87.1±16.8 and 62.2±21.7%, respectively.  ICS also showed a good effect in shoulder fractures and pain after a  stroke. The number of local adverse reactions after injections was  insignificant (4.4%; they did not threaten the health of patients and they caused ICS to be discontinued only in 3 cases. IGS was  investigated in two trials (n=154, which confirmed its efficacy (total pain relief >50% and relative safety. Thus, the data of Russian trials suggest that ICS and IGS have good therapeutic potential and favorable tolerance.

  7. Modifying the ECC-based grouping-proof RFID system to increase inpatient medication safety.

    Science.gov (United States)

    Ko, Wen-Tsai; Chiou, Shin-Yan; Lu, Erl-Huei; Chang, Henry Ker-Chang

    2014-09-01

    RFID technology is increasingly used in applications that require tracking, identification, and authentication. It attaches RFID-readable tags to objects for identification and execution of specific RFID-enabled applications. Recently, research has focused on the use of grouping-proofs for preserving privacy in RFID applications, wherein a proof of two or more tags must be simultaneously scanned. In 2010, a privacy-preserving grouping proof protocol for RFID based on ECC in public-key cryptosystem was proposed but was shown to be vulnerable to tracking attacks. A proposed enhancement protocol was also shown to have defects which prevented proper execution. In 2012, Lin et al. proposed a more efficient RFID ECC-based grouping proof protocol to promote inpatient medication safety. However, we found this protocol is also vulnerable to tracking and impersonation attacks. We then propose a secure privacy-preserving RFID grouping proof protocol for inpatient medication safety and demonstrate its resistance to such attacks.

  8. Prosthetic Oral Rehabilitation of a Child With S-ECC: A Case Report with Histopathologic Analysis.

    Science.gov (United States)

    Tannure, P N; Moraes, G G; Borba, McU; Abrahão, A; Andrade, Mtrc; Fidalgo, Tks

    2015-01-01

    The aim of this case report is to describe the treatment planning of a young child with severe early childhood caries (S-ECC) as well as the prosthetic rehabilitation technique. A 3-year-old female child was referred to the pediatric dentistry clinic with the chief complaint of tooth pain, difficulty in eating and recurrent hospitalizations caused by dental infections. The mother reported intermittent episodes of fever and recurrent swelling of child's face. The girl presented angular cheilitis and was referred to a dietitian. The treatment plain consisted on a behavior changes in oral hygiene habits, exodontias of all primary teeth and oral rehabilitation with a prosthesis. The extracted teeth with periapical lesions were submitted to histopathologic analysis (hematoxilin and eosin staining) and revealed an inflammatory infiltrate. The aesthetic requirement of children with S-ECC has been a challenge to pediatric dentists. In the present case, the oral rehabilitation provided for the children better aesthetic, nutrition, phonation, and functional conditions.

  9. Minimum containment pressure and its effect on ECCS performance of APR-1400

    International Nuclear Information System (INIS)

    Kim, In Goo; Bang, Young S.; Kim, Hho Jung

    2004-01-01

    The containment pressure has a strong effect on the late reheat behavior for a large break LOCA, associated with the DVI issue. The downcomer boiling, which occurs during the post-reflood phase, has a negative effect on core cooling for a LBLOCA. Because the downcomer boiling is enhanced as the containment pressure decreases, how to determine containment pressure is important to the evaluation of ECCS performance. In spite of its importance of containment pressure, there are few studies on the containment pressure and the interaction between RCS and containment thermal hydraulics. To have a better knowledge of the effect of containment pressure on APR-1400 ECCS performance, a parametric study for containment pressure has been carried out. Also, the interaction between RCS and containment behavior has been also investigated

  10. Modeling and Experiments on Injection into University of Maryland Electron Ring

    International Nuclear Information System (INIS)

    Bai, G.; Kishek, R. A.; Beaudoin, B.; Bernal, S.; Feldman, D.; Godlove, T.; Haber, I.; Quinn, B.; Reiser, M.; Sutter, D.; Walter, M.; O'Shea, P. G.

    2006-01-01

    The University of Maryland Electron Ring (UMER) is built as a low-cost testbed for intense beam physics for benefit of larger ion accelerators. The beam intensity is designed to be variable, spanning the entire range from low current operation to highly space-charge-dominated transport. The ring has been closed and multi-turn commissioning has begun. One of the biggest challenges of multi-turn operation of UMER is correctly operating the Y-shaped injection/recirculation section, which is specially designed for UMER multi-turn operation. It is a challenge because the system requires several quadrupoles and dipoles in a very stringent space, resulting in mechanical, electrical, and beam control complexities. Also, the Earth's magnetic field and the image charge effects have to be investigated because they are strong enough to impact the beam centroid motion. This paper presents both simulation and experimental study of the beam centroid motion in the injection region to address above issues

  11. Asymptotic analysis soot model and experiment for a directed injection engine

    Science.gov (United States)

    Liu, Yongfeng; Pei, Pucheng; Xiong, Qinghui; Lu, Yong

    2012-09-01

    The existing soot models are either too complex and can not be applied to the internal combustion engine, or too simple to make calculation errors. Exploring the soot model becomes the pursuit of the goal of many researchers within the error range in the current computer speed. On the basis of the latest experimental results, TP (temperature phases) model is presented as a new soot model to carry out optimization calculation for a high-pressure common rail diesel engine. Temperature and excess air factor are the most important two parameters in this model. When zone temperature T0.6, only the soot precursors—polycyclic aromatic hydrocarbons(PAH) is created and there is no soot emission. When zone temperature T ⩾ 1 500 K and excess air factor Φinjection time, variation of rail pressure and variation of speed among TP models. The experimental results indicate that the TP model can carry out optimization and computational fluid dynamics can be a tool to calculate for a high-pressure common rail directed injection diesel engine. The TP model result is closer than the use of the original KIVA-3V results of soot model accuracy by about 50% and TP model gives a new method for engine researchers.

  12. Transient changes in shallow groundwater chemistry during the MSU ZERT CO2 injection experiment

    Science.gov (United States)

    Apps, J.A.; Zheng, Lingyun; Spycher, N.; Birkholzer, J.T.; Kharaka, Y.; Thordsen, J.; Kakouros, E.; Trautz, R.

    2011-01-01

    Food-grade CO2 was injected into a shallow aquifer through a perforated pipe placed horizontally 1-2 m below the water table at the Montana State University Zero Emission Research and Technology (MSU-ZERT) field site at Bozeman, Montana. The possible impact of elevated CO2 levels on groundwater quality was investigated by analyzing 80 water samples taken before, during, and following CO2 injection. Field determinations and laboratory analyses showed rapid and systematic changes in pH, alkalinity, and conductance, as well as increases in the aqueous concentrations of trace element species. The geochemical data were first evaluated using principal component analysis (PCA) in order to identify correlations between aqueous species. The PCA findings were then used in formulating a geochemical model to simulate the processes likely to be responsible for the observed increases in the concentrations of dissolved constituents. Modeling was conducted taking into account aqueous and surface complexation, cation exchange, and mineral precipitation and dissolution. Reasonable matches between measured data and model results suggest that: (1) CO2 dissolution in the groundwater causes calcite to dissolve. (2) Observed increases in the concentration of dissolved trace metals result likely from Ca+2-driven ion exchange with clays (smectites) and sorption/desorption reactions likely involving Fe (hydr)oxides. (3) Bicarbonate from CO2 dissolution appears to compete for sorption with anionic species such as HAsO4-2, potentially increasing dissolved As levels in groundwater. ?? 2011 Published by Elsevier Ltd.

  13. The E.C.C. programme in the field of radioactive wastes

    International Nuclear Information System (INIS)

    Orlowski, S.

    1976-01-01

    After a description of the aims of the E.C.C. in the field of radioactive wastes, the contents and the structure of the programme developed for this purpose as well as its time schedule and financing, are presented. The state of work progress and the first results of the actions taken, whose application is marked by an active cooperation of numerous national experts are quoted [fr

  14. Audit of ECCS Availability for CANDU Reactors with an extended O/H interval

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jong Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-10-15

    KINS conducts regulatory periodic inspections of the safety and performance of each nuclear installation during the planned outage every 20 months, pursuant to the Atomic Energy Act. For CANDU reactors, planned outage or overhaul (O/H) have been performed every 15 months. KHNP has been making efforts to extend the O/H intervals of CANDU reactors into 20 months since 2001. Low ECCS availability is one of the regulatory pending issues in the related licensing

  15. Charge exchange measurements of MHD activity during neutral beam injection in the Princeton Large Torus and the Poloidal Divertor Experiment

    International Nuclear Information System (INIS)

    Goldston, R.J.; Kaita, R.; Beiersdorfer, P.; Gammel, G.; Herndon, D.L.; McCune, D.C.; Meyerhofer, D.D.

    1987-01-01

    The horizontally scanning, multi-angle charge exchange analysers on the Princeton Large Torus (PLT) and the Poloidal Divertor Experiment (PDX) were used to study the effects of MHD activity on the background ion distribution function and on the beam ion slowing-down process during high power neutral injection. Sawtooth oscillations were observed in the fast ion flux on PLT and PDX, and measurements with neutral beams providing local neutral density enhancement indicated that the ions were transported radially when these events occurred. With near-perpendicular injection in PDX, at the lower toroidal fields necessary to maximize the plasma beta, repetitive bursts of greatly enhanced charge exchange flux were observed. These were associated with the 'fishbone' MHD instability, and a substantial depletion of the perpendicular slowing-down spectrum below the injection energy was seen. A simple phenomenological model for this loss mechanism was developed, and its use in simulation codes has been successful in providing good agreement with the experimental data. The behaviour and characteristics of this model are well matched by direct theoretical calculations. (author)

  16. Early Experience in 100 Consecutive Patients With Injection Adipocytolysis for Neck Contouring With ATX-101 (Deoxycholic Acid).

    Science.gov (United States)

    Shridharani, Sachin M

    2017-07-01

    Deoxycholic acid (DCA) is approved for improvement in the appearance of moderate to severe convexity or fullness associated with submental fat. To assess early treatment experience with DCA injection in a clinical practice setting. In this single-center, prospective, single-arm, observational study, 100 consecutive patients seeking to decrease submental fullness received subcutaneous DCA (2 mg/cm) injections in the submental area (maximum of 6 sessions at ≥1 month intervals). Treatment response was assessed 1 and 5 to 7 weeks posttreatment using the clinician-reported submental fat rating scale (CR-SMFRS) and retrospective independent photograph review by 2 physicians. Overall, 100 patients had 152 treatment sessions (58, 33, 8, and 1 patients had 1, 2, 3, and 4 sessions, respectively). CR-SMFRS score improved by ≥1 point from baseline in 88 (88%) patients; of these, 46, 33, 8, and 1 patients had 1, 2, 3, and 4 sessions, respectively. Local edema, numbness, and tenderness were reported for a mean (SD) of 7.7 (5.3), 28.5 (11.4), and 3.5 (3.5) days, respectively. Two patients experienced marginal mandibular nerve paresis. Deoxycholic acid injection, a minimally invasive procedure for neck contouring, was effective and generally well tolerated in the private practice setting.

  17. A Secure-Enhanced Data Aggregation Based on ECC in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Qiang Zhou

    2014-04-01

    Full Text Available Data aggregation is an important technique for reducing the energy consumption of sensor nodes in wireless sensor networks (WSNs. However, compromised aggregators may forge false values as the aggregated results of their child nodes in order to conduct stealthy attacks or steal other nodes’ privacy. This paper proposes a Secure-Enhanced Data Aggregation based on Elliptic Curve Cryptography (SEDA-ECC. The design of SEDA-ECC is based on the principles of privacy homomorphic encryption (PH and divide-and-conquer. An aggregation tree disjoint method is first adopted to divide the tree into three subtrees of similar sizes, and a PH-based aggregation is performed in each subtree to generate an aggregated subtree result. Then the forged result can be identified by the base station (BS by comparing the aggregated count value. Finally, the aggregated result can be calculated by the BS according to the remaining results that have not been forged. Extensive analysis and simulations show that SEDA-ECC can achieve the highest security level on the aggregated result with appropriate energy consumption compared with other asymmetric schemes.

  18. Gonioscopic changes in conventional ECCE vs manual SICS: A comparative study

    Directory of Open Access Journals (Sweden)

    Surya Joseph, Sundararajan D, Rajvin Samuel Ponraj, Srinivasan M, Veluchamy

    2014-04-01

    Full Text Available The aim of the study is to observe and compare the Gonioscopic changes in the angle of the anterior chamber of the eye after surgeries namely; Conventional Extra capsular cataract extraction (ECCE with Posterior chamber Intraocular lens (PC IOL implantation, Manual Small incision Cataract Surgery with PCIOL implantation. The clinical study was undertaken after Institutional Ethical committee clearance, securing the inform consent, total number of 100 patients were enrolled in the study. 50 ECCE; 50 SICS consisting of 57 Males and 43 Females aged between 40 – 80yrs who were admitted and operated for Cataract at Meenakshi Medical college Hospital & Research institute. The following parameters are studied: Gonioscopic changes in the angle, namely the PAS formation in the quadrants, pigment dispersion in each of the methods. After this study, we arrive to a conclusion that complications in the angle of anterior chamber occur mostly in Conventional with insignificant change in manual SICS. So manual Small incision Cataract Surgery with PCIOL implantation is preferable over Conventional ECCE with PCIOL implantation.

  19. Injection Experiments in Jutphaas; Injection au Centre de Jutphaas; Ehksperimenty s inzhektsiej v institute fiziki plazmy v yutfaas; Experimentos de Inyeccion en Jutphaas

    Energy Technology Data Exchange (ETDEWEB)

    De Kluiver, H.; Brandt, H. B.; Strijland, W.; Huizenga, W. [Fom-Instituut voor Plasma-Fysica, Runhuizen, Jutphaas (Netherlands)

    1966-04-15

    Experiments have been performed on injection parallel to the axis of a cusped magnetic field in a nonadiabatic regime. In a model experiment using an electron beam, half of the injected current gets temporarily trapped. Confiinement time versus magnetic field is found to agree with orbit analysis. With external electrostatic fields complete confinement was obtained except for losses associated with collisions with the background gas. Proton beams of 75 mA at 15 kV were extracted from a protruding plasma ion source in pulses with falloff times of 2 {mu}sec. At a field strength of 13 kG, a net current of 35 mA entered the cusp, of which 15 mA penetrated the opposite end. A collector in the ring cusp measured loss currents. Decay time was 50 {mu}sec, being about two times our best estimate of the charge exchange time, and ten times the value deduced from the analysis of nonadiabatic orbits. Integration of these currents over the ring cusp gives there a loss of 10 to 20 mA. From these figures follows an average density of 0.5 x 10{sup 9} ion cm{sup -3}. A probe of special geometry, collecting only hot ions, showed generally the same current history as ordinary probes. At an H{sub 2} pressure of 10{sup -5} Torr, X-rays have been observed which are ascribed to beam-plasma effects. Within 10 to 20 {mu}sec, they fall to 20% of their value before beam turn-off, followed by a slower decay with an e-folding time of 50 {mu}sec. Radial probing of the plasma showed a considerable increase in collected current towards the centre with a simultaneous decrease in decay time. The measurements suggest that during injection a positive space charge is built up in the centre. This fills continuously the outer, more adiabatic, region of the cusp. After beam turn-off, the particles in the nonadiabatic region are quickly depleted, while particles in the adiabatic region leave much more slowly (50 {mu}sec). (author) [French] Les auteurs ont procede a des experiences sur l'injection parallele

  20. Quorum sensing in the plant pathogen Erwinia carotovora subsp. carotovora: the role of expR(Ecc).

    Science.gov (United States)

    Andersson, R A; Eriksson, A R; Heikinheimo, R; Mäe, A; Pirhonen, M; Kõiv, V; Hyytiäinen, H; Tuikkala, A; Palva, E T

    2000-04-01

    The production of the main virulence determinants of the plant pathogen Erwinia carotovora subsp. carotovora, the extracellular cell wall-degrading enzymes, is partly controlled by the diffusible signal molecule N-(3-oxohexanoyl)-L-homoserine lactone (OHHL). OHHL is synthesized by the product of the expI/carI gene. Linked to expI we found a gene encoding a putative transcriptional regulator of the LuxR-family. This gene, expR(Ecc), is transcribed convergently to the expI gene and the two open reading frames are partially overlapping. The ExpR(Ecc) protein showed extensive amino acid sequence similarity to the repressor EsaR from Pantoea stewartii subsp. stewartii (formerly Erwinia stewartii subsp. stewartii) and to the ExpR(Ech) protein of Erwinia chrysanthemi. Inactivation of the E. carotovora subsp. carotovora expR(Ecc) gene caused no decrease in virulence or production of virulence determinants in vitro. In contrast, there was a slight increase in the maceration capacity of the mutant strain. The effects of ExpR(Ecc) were probably mediated by changes in OHHL levels. Inactivation of expR(Ecc) resulted in increased OHHL levels during early logarithmic growth. In addition, overexpression of expR(Ecc) caused a clear decrease in the production of virulence determinants and part of this effect was likely to be caused by OHHL binding to ExpR(Ecc). ExpR(Ecc) did not appear to exhibit transcriptional regulation of expI, but the effect on OHHL was apparently due to other mechanisms.

  1. TFTR neutral beam D-T gas injection system operational experiences of the first two years

    International Nuclear Information System (INIS)

    Oldaker, M.E.; Lawson, J.E.; Stevenson, T.N.; Kamperschroer, J.H.

    1995-01-01

    The TFTR Neutral Beam Tritium Gas Injection System (TGIS) has successfully performed tritium operations since December 1993. TGIS operation has been reliable, with no leaks to the secondary containment to date. Notable operational problems include throughput leaks on fill, exit and piezoelectric valves. Repair of a TGIS requires replacement of the assembly, involving TFTR downtime and extensive purging, since the TGIS assembly is highly contaminated with residual tritium, and is located within secondary containment. Modifications to improve reliability and operating range include adjustable reverse bias voltage to the piezoelectric valves, timing and error calculation changes to tune the PLC and hardwired timing control, and exercising piezoelectric valves without actually pulsing gas prior to use after extended inactivity. A pressure sensor failure required the development of an open loop piezoelectric valve drive control scheme, using a simple voltage ramp to partially compensate for declining plenum pressure. Replacement of TGIS's have been performed, maintaining twelve system tritium capability as part of scheduled project maintenance activity

  2. Initial Thomson Scattering Survey of Local Helicity Injection and Ohmic Plasmas at the Pegasus Toroidal Experiment

    Science.gov (United States)

    Schlossberg, D. J.; Bodner, G. M.; Bongard, M. W.; Fonck, R. J.; Winz, G. R.

    2014-10-01

    A multipoint Thomson scattering diagnostic has recently been installed on the Pegasus ST. The system utilizes a frequency-doubled Nd:YAG laser (λ0 ~ 532 nm), spectrometers with volume phase holographic gratings, and a gated, intensified CCD camera. It provides measurements of Te and ne at 8 spatial locations for each spectrometer once per discharge. A new multiple aperture and beam dump system has been implemented to mitigate interference from stray light. This system has provided initial measurements in the core region of plasmas initiated by local helicity injection (LHI), as well as conventional Ohmic L- and H-mode discharges. Multi-shot averages of low-density (ne ~ 3 ×1018 m-3) , Ip ~ 0 . 1 MA LHI discharges show central Te ~ 75 eV at the end of the helicity injection phase. Ip ~ 0 . 13 MA Ohmic plasmas at moderate densities (ne ~ 2 ×1019 m-3) have core Te ~ 150 eV in L-mode. Generally, these plasmas do not reach transport equilibrium in the short 25 ms pulse length available. After an L-H transition, strong spectral broadening indicates increasing Te, to values above the range of the present spectrometer system with a high-dispersion VPH grating. Near-term system upgrades will focus on deploying a second spectrometer, with a lower-dispersion grating capable of measuring the 0.1-1.0 keV range. The second spectrometer system will also increase the available number of spatial channels, enabling study of H-mode pedestal structure. Work supported by US DOE Grant DE-FG02-96ER54375.

  3. Intricate and Cell Type-Specific Populations of Endogenous Circular DNA (eccDNA) in Caenorhabditis elegans and Homo sapiens.

    Science.gov (United States)

    Shoura, Massa J; Gabdank, Idan; Hansen, Loren; Merker, Jason; Gotlib, Jason; Levene, Stephen D; Fire, Andrew Z

    2017-10-05

    Investigations aimed at defining the 3D configuration of eukaryotic chromosomes have consistently encountered an endogenous population of chromosome-derived circular genomic DNA, referred to as extrachromosomal circular DNA (eccDNA). While the production, distribution, and activities of eccDNAs remain understudied, eccDNA formation from specific regions of the linear genome has profound consequences on the regulatory and coding capabilities for these regions. Here, we define eccDNA distributions in Caenorhabditis elegans and in three human cell types, utilizing a set of DNA topology-dependent approaches for enrichment and characterization. The use of parallel biophysical, enzymatic, and informatic approaches provides a comprehensive profiling of eccDNA robust to isolation and analysis methodology. Results in human and nematode systems provide quantitative analysis of the eccDNA loci at both unique and repetitive regions. Our studies converge on and support a consistent picture, in which endogenous genomic DNA circles are present in normal physiological states, and in which the circles come from both coding and noncoding genomic regions. Prominent among the coding regions generating DNA circles are several genes known to produce a diversity of protein isoforms, with mucin proteins and titin as specific examples. Copyright © 2017 Shoura et al.

  4. EMC3-EIRENE modeling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Lore, J.D., E-mail: lorejd@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Reinke, M.L. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); LaBombard, B. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Lipschultz, B. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Churchill, R.M. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Feng, Y. [Max Planck Institute for Plasma Physics, Greifswald (Germany)

    2015-08-15

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ∼50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modeling, with the simulation yielding a toroidal asymmetry in the heat flow to the outer strike point. Toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.

  5. Treatment of hyperfunctioning thyroid nodules with percutaneous ethanol injection: Eight years' experience.

    Science.gov (United States)

    Monzani, F; Caraccio, N; Goletti, O; Casolaro, A; Lippolis, P V; Cavina, E; Miccoli, P

    1998-01-01

    The aim of our study was to define the long-term efficacy and safety of percutaneous ethanol injection (PEI) for the treatment of autonomous thyroid nodule (ATN), and to optimise the clinical usefulness of such a therapy. We treated 132 patients with ATN (30 M and 102 F, aged 47.5+/-12.9 years; mean+/-SD), in case other established treatments were refused or contraindicated. Eighty-five patients were affected by toxic adenoma and 47 suffered from pre-toxic nodules. Ethanol was administered weekly under sonographic control, in 7 sessions (range 2-16). During PEI treatment, 26 toxic elderly patients were treated with methimazole and propranolol. Three possible outcomes were identified for statistical analysis: failure (persistent suppression of extra nodular tissue uptake, along with elevated free thyroid hormone and undetectable TSH levels); partial cure (normal free thyroid hormone and low/undetectable TSH levels); complete cure (normal thyroid hormone and TSH levels; restored extra nodular uptake). The patients were followed for up to 8.5 years (median 76 months). PEI therapy was well tolerated by all patients though a mild to moderate local pain occurred in about 30% of sessions. Complete cure was achieved in all pre-toxic patients and in 60 (70.6%) patients with toxic adenoma, while partial cure was observed in 11 cases (12.9%) and failure in 14 (16.5%). A significant shrinkage of nodule volume was observed in all patients (p = 0.0001), while those with toxic nodules larger than 30 mL showed a significantly lower response rate to PEI (p thyroid adenoma where therapy is least necessary- despite the nodule volume. Though ethanol injection therapy of toxic thyroid nodules may be troublesome for the need of multiple sessions, it appears an effective alternative procedure in patients at poor surgical risk, and in younger patients in whom radioiodine is contraindicated. Since a special technical skill in intervention procedures is required, PEI therapy may be suitable

  6. Direct vessel inclined injection system for reduction of emergency core coolant direct bypass in advanced reactors

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Lee, Jong G.; Suh, Kune Y.

    2006-01-01

    Multidimensional thermal hydraulics in the APR1400 (Advanced Power Reactor 1400 MWe) downcomer during a large-break loss-of-coolant accident (LBLOCA) plays a pivotal role in determining the capability of the safety injection system. APR1400 adopts the direct vessel injection (DVI) method for more effective core penetration of the emergency core cooling (ECC) water than the cold leg injection (CLI) method in the OPR1000 (Optimized Power Reactor 1000 MWe). The DVI method turned out to be prone to occasionally lack in efficacious delivery of ECC to the reactor core during the reflood phase of a LBLOCA, however. This study intends to demonstrate a direct vessel inclined injection (DVII) method, one of various ideas with which to maximize the ECC core penetration and to minimize the direct bypass through the break during the reflood phase of a LBLOCA. The 1/7 scaled down THETA (Transient Hydrodynamics Engineering Test Apparatus) tests show that a vertical inclined nozzle angle of the DVII system increases the downward momentum of the injected ECC water by reducing the degree of impingement on the reactor downcomer, whereby lessening the extent of the direct bypass through the break. The proposed method may be combined with other innovative measures with which to ensure an enough thermal margin in the core during the course of a LBLOCA in APR1400

  7. Exxon Nuclear Company ECCS evaluation of a 2-loop Westinghouse PWR with dry containment using the ENC WREM-II ECCS model. Large break example problem

    International Nuclear Information System (INIS)

    Krajicek, J.E.

    1977-01-01

    This document is presented as a demonstration of the ENC WREM-II ECCS model calculational procedure applied to a Westinghouse 2-loop PWR with a dry containment (R. E. Ginna plant, for example). The hypothesized Loss-of-Coolant Accident (LOCA) investigated was a split break with an area equal to twice the pipe cross-sectional area. The break was assumed to occur in one pump discharge pipe (DECLS break). The analyses involved calculations using the ENC WREM-II model. The following codes were used: RELAP4-EM/ENC26A for blowdown and hot channel analyses, RELAP4-EM FLOOD/ENC26A for core reflood analysis, CONTEMPT LT/22 modified for containment backpressure analysis, and TOODEE2/APR77 for heatup analysis

  8. Autologous fat injection combined with palatoplasty and pharyngoplasty for velopharyngeal insufficiency and cleft palate: preliminary experience.

    Science.gov (United States)

    Cao, Yimei; Ma, Tingting; Wu, Di; Yin, Ningbei; Zhao, Zhenmin

    2013-08-01

    The aim was to evaluate clinical application of autologous fat transplantation in the posterior pharynx to treat velopharyngeal incompetence and cleft palate. Case series with chart review. Cleft Lip and Palate Center of Plastic Surgery Hospital, an academic medical center. We studied 11 patients (age, 5-26 years) with a cleft palate and velopharyngeal insufficiency who underwent autologous fat injection. Patients were followed for 9 to 40 months. Pronunciation evaluation, visual appearance of the palatopharyngeal area, nasopharyngeal fibroscopy (NPF), palatopharyngeal lateral radiography, and magnetic resonance imaging (MRI) were undertaken before and after the operation. Speech intelligibility was markedly increased in all patients. Pronunciation was good to excellent compared with the preoperative level (P = .001). Mean velopharyngeal insufficiency rate was significantly reduced from 26.05% to 6.96% (P = .028) by NPF and from 26.42% to 7.11% (P = .017) by MRI (axial plane). Magnetic resonance imaging indicated significantly reduced mean minimum velopharyngeal distance, from 10.39 to 3.65 mm (P = .012) in the sagittal plane, and markedly increased thickness of transplanted fat in the posterior pharyngeal wall (sagittal, 5.43 mm; axial, 4.74 mm). There were few complications (sleep apnea, nasopharyngeal regurgitation). Autologous fat transplantation in the posterior pharyngeal wall was a good method for treating velopharyngeal incompetence. The safety profile was good in our sample, and we got a consistent result in the follow-up period. In addition, it also could be combined with routine surgery.

  9. Verification of the code ATHLET by post-test analysis of two experiments performed at the CCTF integral test facility

    International Nuclear Information System (INIS)

    Krepper, E.; Schaefer, F.

    2001-03-01

    In the framework of the external validation of the thermohydraulic code ATHLET Mod 1.2 Cycle C, which has been developed by the GRS, post test analyses of two experiments were done, which were performed at the japanese test facility CCTF. The test facility CCTF is a 1:25 volume-scaled model of a 1000 MW pressurized water reactor. The tests simulate a double end break in the cold leg of the PWR with ECC injection into the cold leg and with combined ECC injection into the hot and cold legs. The evaluation of the calculated results shows, that the main phenomena can be calculated in a good agreement with the experiment. Especially the behaviour of the quench front and the core cooling are calculated very well. Applying a two-channel representation of the reactor model the radial behaviour of the quench front could be reproduced. Deviations between calculations and experiment can be observed simulating the emergency injection in the beginning of the transient. Very high condensation rates were calculated and the pressure decrease in this phase of the transient is overestimated. Besides that, the pressurization due to evaporation in the refill phase is underestimated by ATHLET. (orig.) [de

  10. Visible Spectrometer at the Compact Toroid Injection Experiment, the Sustained Spheromak Plasma Experiment and the Alcator C-Mod Tokamak for Doppler Width and Shift Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Graf, A; Howard, S; Horton, R; Hwang, D; May, M; Beiersdorfer, P; McLean, H; Terry, J

    2006-05-15

    A novel Doppler spectrometer is currently being used for ion or neutral velocity and temperature measurements on the Alcator C-Mod Tokamak. The spectrometer has an f/No. of {approx}3.1 and is appropriate for visible light (3500-6700 {angstrom}). The full width at half maximum from a line emitting calibration source has been measured to be as small as 0.4 {angstrom}. The ultimate time resolution is line brightness light limited and on the order of ms. A new photon efficient detector is being used for the setup at C-Mod. Time resolution is achieved by moving the camera during a plasma discharge in a perpendicular direction through the dispersion plane of the spectrometer causing a vertical streaking across the camera face. Initial results from C-Mod as well as previous measurements from the Compact Toroid Injection Experiment (CTIX) and the Sustained Spheromak Plasma Experiment (SSPX) are presented.

  11. Experiments on the behaviour of thermite melt injected into sodium: Final report on the THINA test results

    International Nuclear Information System (INIS)

    Huber, F.; Kaiser, A.; Peppler, W.

    1994-01-01

    During hypothetical accidents of fast breeder reactors the core melts and part of the core material inventory is ejected into the upper coolant plenum. As a consequence, a fuel to coolant thermal interaction occurs between the melt and the sodium. A series of simulating experiments was carried out in KfK/IRS to improve the knowledge about the phenomenology of molten fuel/coolant interactions and to support theoretical work on the safety of fast breeder reactors. In the tests, a thermite melt of up to 3270 K is injected from below into a sodium pool the temperature of which is between 770 and 820 K. The masses of the melt and the sodium are about five and 150 kg, respectively. Thermal interactions have been observed to occur as a sequence of small local pressure events mainly during the melt injection. Large-scale vapour explosions have not been observed. Generally, the conversion ratios of thermal to mechanical energy have been low. (author)

  12. Review: study of single-pellet injection experiments and development of pellet injector in JFT-2M

    International Nuclear Information System (INIS)

    Kasai, Satoshi; Miura, Yukitoshi; Hasegawa, Kouichi; Sengoku, Seio

    1987-10-01

    The single pellet injector developed for JFT-2M and the improvement of plasma characteristics in the auxiliary-heated discharges by single-pellet injection are reviewed for the period 1982 - 1986. The pellet injector is a pneumatic type and the designed pellet size is 1.65 mmD x 1.65 mmL and 1 mmD x 1 mmL. The hydrogen, deuterium and mixed (H 2 + D 2 ) pellets can be produced with good reproducibility. Maximum pellet velocity is about 970 m/s (pellet is deuterium and propellant gas is hydrogen). In the pellet injection experiments into auxiliary-heated (NB, ICRF) divertor or limiter discharges, the plasma confinement time is improved by a factor of 1.4 - 1.7 compared with the confinement time in the Ohmic discharges. The achieved confinement time is longer than that on the high confinement mode (H-mode) in gas fueled discharges, although the phenomena are transient. (author)

  13. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic BZ

    International Nuclear Information System (INIS)

    Arpinar, V E; Muftuler, L T; Hamamura, M J; Degirmenci, E

    2012-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique, electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently, the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as IEC601. This protocol limits patient auxiliary currents to 100 µA for low frequencies. However, published MREIT studies have utilized currents 10–400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200 µA total injected current and tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul (1998 Elektrik 6 215–25) with Tikhonov regularization and the harmonic B Z proposed by Oh et al (2003 Magn. Reason. Med. 50 875–8). The reconstruction techniques were tested at both 200 µA and 5 mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200 µA total injected current into a cylindrical phantom generates only 14.7 µA current in imaging slice. Similarly, 5 mA total injected current results in 367 µA in imaging slice. Total acquisition

  14. Paper 58714 - Exploring activated faults hydromechanical processes from semi-controled field injection experiments

    Science.gov (United States)

    Guglielmi, Y.; Cappa, F.; Nussbaum, C.

    2015-12-01

    The appreciation of the sensitivity of fractures and fault zones to fluid-induced-deformations in the subsurface is a key question in predicting the reservoir/caprock system integrity around fluid manipulations with applications to reservoir leakage and induced seismicity. It is also a question of interest in understanding earthquakes source, and recently the hydraulic behavior of clay faults under a potential reactivation around nuclear underground depository sites. Fault and fractures dynamics studies face two key problems (1) the up-scaling of laboratory determined properties and constitutive laws to the reservoir scale which is not straightforward when considering faults and fractures heterogeneities, (2) the difficulties to control both the induced seismicity and the stimulated zone geometry when a fault is reactivated. Using instruments dedicated to measuring coupled pore pressures and deformations downhole, we conducted field academic experiments to characterize fractures and fault zones hydromechanical properties as a function of their multi-scale architecture, and to monitor their dynamic behavior during the earthquake nucleation process. We show experiments on reservoir or cover rocks analogues in underground research laboratories where experimental conditions can be optimized. Key result of these experiments is to highlight how important the aseismic fault activation is compared to the induced seismicity. We show that about 80% of the fault kinematic moment is aseismic and discuss the complex associated fault friction coefficient variations. We identify that the slip stability and the slip velocity are mainly controlled by the rate of the permeability/porosity increase, and discuss the conditions for slip nucleation leading to seismic instability.

  15. Experimental demonstration of tokamak inductive flux saving by transient coaxial helicity injection on national spherical torus experiment

    Energy Technology Data Exchange (ETDEWEB)

    Raman, R.; Jarboe, T. R.; Nelson, B. A. [University of Washington, Seattle, Washington 98195 (United States); Mueller, D.; Bell, M. G.; Gerhardt, S.; LeBlanc, B.; Menard, J.; Ono, M.; Roquemore, L. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Soukhanovskii, V. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)

    2011-09-15

    Discharges initiated by transient coaxial helicity injection in National Spherical Torus Experiment have attained peak toroidal plasma currents up to 300 kA. When induction from the central solenoid is then applied, these discharges develop up to 300 kA additional current compared to discharges initiated by induction only. CHI initiated discharges in NSTX have achieved 1 MA of plasma current using only 258 mWb of solenoid flux whereas standard induction-only discharges require about 50% more solenoid flux to reach 1 MA. In addition, the CHI-initiated discharge has lower plasma density and a low normalized internal plasma inductance of 0.35, as needed for achieving advanced scenarios in NSTX.

  16. Colliding pulse injection experiments in non-collinear geometry for controlled laser plasma wakefield acceleration of electrons

    International Nuclear Information System (INIS)

    Toth, Carl B.; Esarey, Eric H.; Geddes, Cameron G.R.; Leemans, Wim P.; Nakamura, Kei; Panasenko, Dmitriy; Schroeder, Carl B.; Bruhwiler, D.; Cary, J.R.

    2007-01-01

    An optical injection scheme for a laser-plasma based accelerator which employs a non-collinear counter-propagating laser beam to push background electrons in the focusing and acceleration phase via ponderomotive beat with the trailing part of the wakefield driver pulse is discussed. Preliminary experiments were performed using a drive beam of a 0 = 2.6 and colliding beam of a 1 = 0.8 both focused on the middle of a 200 mu m slit jet backed with 20 bar, which provided ∼ 260 mu m long gas plume. The enhancement in the total charge by the colliding pulse was observed with sharp dependence on the delay time of the colliding beam. Enhancement of the neutron yield was also measured, which suggests a generation of electrons above 10 MeV

  17. Assessment of compliance with regulatory requirements for a best estimate methodology for evaluation of ECCS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Un Chul; Jang, Jin Wook; Lim, Ho Gon; Jeong, Ik [Seoul National Univ., Seoul (Korea, Republic of); Sim, Suk Ku [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2000-03-15

    Best estimate methodology for evaluation of ECCS proposed by KEPCO(KREM) os using thermal-hydraulic best-estimate code and the topical report for the methodology is described that it meets the regulatory requirement of USNRC regulatory guide. In this research the assessment of compliance with regulatory guide. In this research the assessment of compliance with regulatory requirements for the methodology is performed. The state of licensing procedure of other countries and best-estimate evaluation methodologies of Europe is also investigated, The applicability of models and propriety of procedure of uncertainty analysis of KREM are appraised and compliance with USNRC regulatory guide is assessed.

  18. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China.

    Science.gov (United States)

    Zhu, Ling-Ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1) improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2) complications associated with vascular access; 3) incidents induced by absence of efficient electronic pump management and infusion tube management; and 4) liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan-do-check-act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety.

  19. Perceptions of community and family level IDU and HIV related stigma, disclosure decisions and experiences with layered stigma among HIV positive injection drug users in Vietnam

    OpenAIRE

    Rudolph, A.E.; Davis, W.W.; Quan, V.M.; Ha, T.V.; Minh, N.L.; Gregowski, A.; Salter, Megan; Celentano, D.D.; Go, V.

    2011-01-01

    This paper explores how perceived stigma and layered stigma related to injection drug use and being HIV positive influence the decision to disclose one’s HIV status to family and community and experiences with stigma following disclosure among a population of HIV positive male injection drug users (IDUs) in Thai Nguyen, Vietnam. In qualitative interviews conducted between 2007 and 2008, 25 HIV positive male IDUs described layered stigma in their community but an absence of layered stigma with...

  20. Corticosteroid injections, eccentric decline squat training and heavy slow resistance training in patellar tendinopathy

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Kovanen, V.; Aagaard, P.

    2009-01-01

    A randomized-controlled single-blind trial was conducted to investigate the clinical, structural and functional effects of peritendinous corticosteroid injections (CORT), eccentric decline squat training (ECC) and heavy slow resistance training (HSR) in patellar tendinopathy. Thirty-nine male...

  1. Multilevel Botulinum Toxin A (Abobotulinum Toxin A Injections in Spastic Forms of Cerebral Palsy: Retrospective Analysis of 8 Russian Centers Experience

    Directory of Open Access Journals (Sweden)

    O. A. Klochkova

    2016-01-01

    Full Text Available Background: The contemporary application of Botulinum toxin A (BTA in cerebral palsy (CP implies multilevel injections both in on-label and off-label muscles. However, there is no single international opinion on the effective and safe dosages, target muscles, and intervals between the injections.Objective: Our aim was to analyze the Russian multicenter independent experience of single and repeated multilevel injections of Abobotulinum toxin А in patients with spastic forms of CP.Methods: 8 independent referral CP-centers (10 hospitals in different regions of Russia. Authors evaluated intervals between the injections, dosages of the BTA for the whole procedure, for the body mass, for the each muscle, and functional segment of the extremities.Results: 1872 protocols of effective BTA injections (1–14 repeated injections for 724 patients with spastic CP were included. The age of the patients was between 8 months to 17 years 4 months at the beginning of the treatment (with a mean of 3 years 10 months. Multilevel BTA injections were indicated for the majority (n = 634, 87.6% of the patients in all the centers. The medians of the dosages for the first BTA injection were between 30–31 U/kg (500 U, the repeated injections doses up to 45 U/kg (1000 U (in most centers. The median intervals between the repeated injections were 180–200 days in 484 (66.9% patients and 140–180 days in 157 (24.7% patients. In 2 centers, children with GMFCS IV–V were injected more often than others.Conclusion: Multilevel BTA injections were indicated for the most patients. The initial dose of Abobotulinum toxin A was 30–31 U/kg. The repeated injections dose could increase up to 40 U/kg. The repeated injections were done in 140–200 days after the previous injection.

  2. Compendium of ECCS [Emergency Core Cooling Systems] research for realistic LOCA [loss-of-coolant accidents] analysis: Final report

    International Nuclear Information System (INIS)

    1988-12-01

    In the United States, Emergency Core Cooling Systems (ECCS) are required for light water reactors (LWRs) to provide cooling of the reactor core in the event of a break or leak in the reactor piping or an inadvertent opening of a valve. These accidents are called loss-of-coolant accidents (LOCA), and they range from small leaks up to a postulated full break of the largest pipe in the reactor cooling system. Federal government regulations provide that LOCA analysis be performed to show that the ECCS will maintain fuel rod cladding temperatures, cladding oxidation, and hydrogen production within certain limits. The NRC and others have completed a large body of research which investigated fuel rod behavior and LOCA/ECCS performance. It is now possible to make a realistic estimate of the ECCS performance during a LOCA and to quantify the uncertainty of this calculation. The purpose of this report is to summarize this research and to serve as a general reference for the extensive research effort that has been performed. The report: (1) summarizes the understanding of LOCA phenomena in 1974; (2) reviews experimental and analytical programs developed to address the phenomena; (3) describes the best-estimate computer codes developed by the NRC; (4) discusses the salient technical aspects of the physical phenomena and our current understanding of them; (5) discusses probabilistic risk assessment results and perspectives, and (6) evaluates the impact of research results on the ECCS regulations. 736 refs., 412 figs., 66 tabs

  3. A provably-secure ECC-based authentication scheme for wireless sensor networks.

    Science.gov (United States)

    Nam, Junghyun; Kim, Moonseong; Paik, Juryon; Lee, Youngsook; Won, Dongho

    2014-11-06

    A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme) is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000). Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC), and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure) schemes.

  4. A Provably-Secure ECC-Based Authentication Scheme for Wireless Sensor Networks

    Science.gov (United States)

    Nam, Junghyun; Kim, Moonseong; Paik, Juryon; Lee, Youngsook; Won, Dongho

    2014-01-01

    A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme) is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000). Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC), and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure) schemes. PMID:25384009

  5. A Provably-Secure ECC-Based Authentication Scheme for Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Junghyun Nam

    2014-11-01

    Full Text Available A smart-card-based user authentication scheme for wireless sensor networks (in short, a SUA-WSN scheme is designed to restrict access to the sensor data only to users who are in possession of both a smart card and the corresponding password. While a significant number of SUA-WSN schemes have been suggested in recent years, their intended security properties lack formal definitions and proofs in a widely-accepted model. One consequence is that SUA-WSN schemes insecure against various attacks have proliferated. In this paper, we devise a security model for the analysis of SUA-WSN schemes by extending the widely-accepted model of Bellare, Pointcheval and Rogaway (2000. Our model provides formal definitions of authenticated key exchange and user anonymity while capturing side-channel attacks, as well as other common attacks. We also propose a new SUA-WSN scheme based on elliptic curve cryptography (ECC, and prove its security properties in our extended model. To the best of our knowledge, our proposed scheme is the first SUA-WSN scheme that provably achieves both authenticated key exchange and user anonymity. Our scheme is also computationally competitive with other ECC-based (non-provably secure schemes.

  6. Factors predisposing to early childhood caries (ECC) in children of pre-school age in the city of Zagreb, Croatia.

    Science.gov (United States)

    Lulić-Dukić, O; Jurić, H; Dukić, W; Glavina, D

    2001-06-01

    The aim of this study was to investigate factors predisposing to early childhood caries (ECC) in pre-school children in the city of Zagreb, Croatia. The investigation was carried out on the sample of 145 children (77 boys and 68 girls) aged between 2 and 5 years, including clinical examination of dental status and survey on the habits among the parents. The overall prevalence of ECC was 30%: in girls it was 25%, and in boys 48%. The study on the risk factors was designed as a classic case-control study. The mean value of dmfs index among the cases amounted to 8.6, in comparison to 5.2 in the control group (pteeth-brushing habit after first 24 months did (p importance of early introduction of teeth-brushing and giving up the nightly consumption of sweet beverages in prevention of ECC.

  7. Adverse allergic reactions to linear ionic gadolinium-based contrast agents: experience with 194, 400 injections

    International Nuclear Information System (INIS)

    Aran, S.; Shaqdan, K.W.; Abujudeh, H.H.

    2015-01-01

    Aim: To report the authors' experience with the administration of four gadolinium-based contrast agents (GBCA; gadopentetate dimeglumine, gadofosveset trisodium, gadoxetate disodium and gadobenate dimeglumine) in a large study population at a single, large academic medical centre. Materials and methods: The institutional review board approved this retrospective study in which data in the electronic incident reporting system were searched. A total of 194, 400 intravenous administrations of linear ionic GBCAs were assessed for the incidence of adverse reactions and risk factors from 1 January 2007 to 14 January 2014. The severity of reactions (mild, moderate, and severe), patient type (outpatients, inpatients, and emergency), examination type, and treatment options were also investigated. Results: In total, 204/194400 (0.1%) patients (mean age 45.7 ± 14.9) showed adverse reactions, consisting of 6/746 (0.80%), 10/3200 (0.31%), 14/6236 (0.22%) and 174/184218 (0.09%), for gadofosveset trisodium, gadoxetate disodium, gadobenate dimeglumine, and gadopentetate dimeglumine, respectively. An overall significant difference was found between different GBCAs regarding the total number of reactions (p < 0.0001). When comparing the GBCAs together, significant differences were found between gadofosveset trisodium versus gadopentetate dimeglumine (p < 0.0001), gadofosveset trisodium versus gadobenate dimeglumine (p = 0.0051), gadoxetate disodium versus gadopentetate dimeglumine (p < 0.0001) and gadopentetate dimeglumine versus gadobenate dimeglumine (p = 0.0013). Rate of reaction was higher in females (F: 146/113187, 0.13%/M: 58/81213, 0.07%; p < 0.0001). Rate of reactions was higher in outpatient (180/158885, 0.11%), emergency (10/10413, 0.10%), and inpatients (14/25102, 0.05%), respectively (p < 0.0001). Most of the patients had mild symptoms 171/204 (83.8%). Abdomen–pelvis, liver, and thoracic examinations had highest rates of reactions (0.17 versus 0

  8. Assessment of some interfacial shear correlations in a model of ECC bypass flow in PWR reactor downcomer

    International Nuclear Information System (INIS)

    Popov, N.K.; Rohatgi, U.S.

    1987-01-01

    The bypass/refill process in the PWR reactor downcomer, following a large rupture of a cold leg coolant supply pipe, is a complicated thermo-hydraulic two-phase flow phenomenon. Mathematical modeling of such phenomena is always accompanied with a difficult task of selection of suitable constitutive correlations. In a typically hydrodynamic phenomenon, like ECC refill process of the reactor lower plenum is considered, the phasic interfacial friction is the most influential constitutive correlation. Therefore, assessment of the well-known widely-used interfacial friction constitutive correlations in the model of ECC bypass/refill process, is the subject of this paper

  9. Mechanical interaction of Engineered Cementitious Composite (ECC) reinforced with Fiber Reinforced Polymer (FRP) rebar in tensile loading

    DEFF Research Database (Denmark)

    Lárusson, Lárus Helgi; Fischer, Gregor; Jönsson, Jeppe

    2010-01-01

    This paper introduces a preliminary study of the composite interaction of Engineered Cementitious Composite (ECC), reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar. The main topic of this paper will focus on the interaction of the two materials (ECC and GFRP) during axial loading......, particularly in post cracking phase of the concrete matrix. The experimental program carried out in this study examined composite behavior under monotonic and cyclic loading of the specimens in the elastic and inelastic deformation phases. The stiffness development of the composite during loading was evaluated...

  10. Factors Predisposing to Early Childhood Caries (ECC) in Children of Pre-School Age in the City of Zagreb, Croatia

    OpenAIRE

    Lulić-Dukić, O.; Jurić, H.; Dukić, W.; Glavina, D.

    2001-01-01

    The aim of this study was to investigate factors predisposing to early childhood caries (ECC) in pre-school children in the city of Zagreb, Croatia. The investigation was carried out on the sample of 145 children (77 boys and 68 girls) aged between 2 and 5 years, including clinical examination of dental status and survey on the habits among the parents. The overall prevalence of ECC was 30%: in girls it was 25%, and in boys 48%. The study on the risk factors was designed as a c...

  11. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People's Republic of China

    Directory of Open Access Journals (Sweden)

    Zhu LL

    2014-03-01

    Full Text Available Ling-ling Zhu,1 Wei Li,2 Ping Song,3 Quan Zhou3 1Geriatric VIP Ward, Division of Nursing, 2Division of Medical Administration, 3Department of Pharmacy, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People's Republic of China Abstract: The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors originate during drug administration; of those errors, about two-thirds involve injectables. Therefore, injection device management is pivotal to safe administration of medications. In this article, the authors summarize the relevant experiences by retrospective analysis of injection device-related near misses and adverse events in the Second Affiliated Hospital of Zhejiang University, School of Medicine, Zhejiang University, People's Republic of China. Injection device-related near misses and adverse events comprised the following: 1 improper selection of needle diameter for subcutaneous injection, material of infusion sets, and pore size of in-line filter; 2 complications associated with vascular access; 3 incidents induced by absence of efficient electronic pump management and infusion tube management; and 4 liquid leakage of chemotherapeutic infusion around the syringe needle. Safe injection drug use was enhanced by multidisciplinary collaboration, especially among pharmacists and nurses; drafting of clinical pathways in selection of vascular access; application of approaches such as root cause analysis using a fishbone diagram; plan–do–check–act and quality control circle; and construction of a culture of spontaneous reporting of near misses and adverse events. Pharmacists must be professional in regards to medication management and use. The depth, breadth, and efficiency of cooperation between nurses and pharmacists are pivotal to injection safety. Keywords

  12. Development of Metal/Polymer Mixtures Dedicated to Macro and Micro powder Injection Moulding : Experiments and Simulations

    International Nuclear Information System (INIS)

    Quinard, C.; Barriere, T.; Gelin, J. C.; Song, J. P.; Cheng, Z. Q.; Liu, B. S.

    2007-01-01

    Important research tasks at ENSMM/LMA are concerned for the development of mixtures of fine powders associated to polymer binders dedicated to the powder injection moulding (PIM) and to the powder injection micro-moulding (μPIM) in accordance with many works already carried out with different feedstock suppliers dedicated to the macro-components. These research tasks are completed with the simulations of injection and sintering for solid state diffusion for to validate the mumerical models

  13. Experiment data of ROSA-III integral test Run 7341

    International Nuclear Information System (INIS)

    Anoda, Yoshinari; Soda, Kunihisa; Tasaka, Kanji

    1983-02-01

    This report presents the test data of Run 7341 in the single failure test series of the ROSA-III program to conduct the system effect test concerning the response of a BWR during a LOCA with the ECC injection. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6 with an electrically heated core and the scaled ECCS. Run 7341 is a double-ended break test at the recirculation pump inlet with the assumption that all ECCS function as designed. The test is initiated with the steam dome pressure of 7.28 MPa, the lower plenum subcooling of 11.0 K, the core inlet flow rate of 15.3 kg/s, and the core heat generation rate of 3.55 MW and proceeded as planned. The whole core is quenched after the ECCS actuation and the maximum fuel cladding temperature is 810 K. The effectiveness of ECC injection has been clarified from the comparison of the test results with those of the other test in the series without ECCS. (author)

  14. Modified ECC ozone sonde for long-duration flights aboard isopicnic drifting balloons

    Science.gov (United States)

    Gheusi, Francois; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clénet, Antoine; Fontaine, Alain; Jambert, Corinne; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore

    2015-04-01

    Since few years, the French space agency CNES has developed boundary-layer pressurized balloons (BLPB) with the capability to transport scientific payloads at isopicnic level over very long distances and durations (up to several weeks in absence of navigation limits). However, the autonomy of conventional electrochemical concentration cell (ECC) ozone sondes, that are widely used for tropospheric and stratospheric soundings, is limited to few hours due to power consumption and electrolyte evaporation (owing to air bubbling in the cathode solution). In collaboration with the French research community, CNES has developed a new ozone payload suited for long duration flights aboard BLPB. The mechanical elements (Teflon pump and motor) and the electrochemical cell of conventional ECC sondes have been kept but the electronic implementation is entirely new. The main feature is the possibility of programming periodic measurement sequences -- with possible remote control during the flight. To increase the ozone sonde autonomy, a strategy has been adopted of short measurement sequences (typically 2-3 min) regularly spaced in time (e.g. every 15 min, which is usually sufficient for air quality studies). The rest of the time, the sonde is at rest (pump motor off). The response time of an ECC sonde to an ozone concentration step is below one minute. Consequently, the measurement sequence is typically composed of a one-minute spin-up period after the pump has been turned on, followed by a one- to two-minute acquisition period. All time intervals can be adjusted before and during the flight. Results of a preliminary ground-based test in spring 2012 are first presented. The sonde provided correct ozone concentrations against a reference UV analyzer every 15 minutes during 4 days. Then we illustrate results from 16 BLBP flights launched in the low troposphere over the Mediterranean during summer field campaings in 2012 and 2013 (TRAQA and ChArMEx programmes). BLPB drifting

  15. Adapted ECC ozonesonde for long-duration flights aboard boundary-layer pressurised balloons

    Science.gov (United States)

    Gheusi, François; Durand, Pierre; Verdier, Nicolas; Dulac, François; Attié, Jean-Luc; Commun, Philippe; Barret, Brice; Basdevant, Claude; Clenet, Antoine; Derrien, Solène; Doerenbecher, Alexis; El Amraoui, Laaziz; Fontaine, Alain; Hache, Emeric; Jambert, Corinne; Jaumouillé, Elodie; Meyerfeld, Yves; Roblou, Laurent; Tocquer, Flore

    2016-12-01

    Since the 1970s, the French space agency CNES has developed boundary-layer pressurised balloons (BLPBs) with the capability to transport lightweight scientific payloads at isopycnic level and offer a quasi-Lagrangian sampling of the lower atmosphere over very long distances and durations (up to several weeks).Electrochemical concentration cell (ECC) ozonesondes are widely used under small sounding balloons. However, their autonomy is limited to a few hours owing to power consumption and electrolyte evaporation. An adaptation of the ECC sonde has been developed specifically for long-duration BLPB flights. Compared to conventional ECC sondes, the main feature is the possibility of programming periodic measurement sequences (with possible remote control during the flight). To increase the ozonesonde autonomy, the strategy has been adopted of short measurement sequences (2-3 min) regularly spaced in time (e.g. every 15 min). The rest of the time, the sonde pump is turned off. Results of preliminary ground-based tests are first presented. In particular, the sonde was able to provide correct ozone concentrations against a reference UV-absorption ozone analyser every 15 min for 4 days. Then we illustrate results from 16 BLBP flights launched over the western Mediterranean during three summer field campaigns of the ChArMEx project (http://charmex.lsce.ipsl.fr): TRAQA in 2012, and ADRIMED and SAFMED in 2013. BLPB drifting altitudes were in the range 0.25-3.2 km. The longest flight lasted more than 32 h and covered more than 1000 km. Satisfactory data were obtained when compared to independent ozone measurements close in space and time. The quasi-Lagrangian measurements allowed a first look at ozone diurnal evolution in the marine boundary layer as well as in the lower free troposphere. During some flight segments, there was indication of photochemical ozone production in the marine boundary layer or even in the free troposphere, at rates ranging from 1 to 2 ppbv h -1, which

  16. Identification of waves by RF magnetic probes during lower hybrid wave injection experiments on the TST-2 spherical tokamak

    International Nuclear Information System (INIS)

    Shinya, Takahiro; Ejiri, Akira; Takase, Yuichi

    2014-01-01

    RF magnetic probes can be used to measure not only the wavevector, but also the polarization of waves in plasmas. A 5-channel RF magnetic probe (5ch-RFMP) was installed in the TST-2 spherical tokamak and the waves were studied in detail during lower hybrid wave injection experiments. From the polarization measurements, the poloidal RF magnetic field is found to be dominant. In addition to polarization, components of k perpendicular to the major radial direction were obtained from phase differences among the five channels. The radial wavenumber was obtained by scanning the radial position of the 5ch-RFMP on a shot by shot basis. The measured wavevector and polarization in the plasma edge region were consistent with those calculated from the wave equation for the slow wave branch. While the waves with small and large k ∥ were excited by the antenna, only the small k ∥ component was measured by the 5ch-RFMP; this suggests that the waves with larger k ∥ were absorbed by the plasma. (author)

  17. A Secure ECC-based RFID Mutual Authentication Protocol to Enhance Patient Medication Safety.

    Science.gov (United States)

    Jin, Chunhua; Xu, Chunxiang; Zhang, Xiaojun; Li, Fagen

    2016-01-01

    Patient medication safety is an important issue in patient medication systems. In order to prevent medication errors, integrating Radio Frequency Identification (RFID) technology into automated patient medication systems is required in hospitals. Based on RFID technology, such systems can provide medical evidence for patients' prescriptions and medicine doses, etc. Due to the mutual authentication between the medication server and the tag, RFID authentication scheme is the best choice for automated patient medication systems. In this paper, we present a RFID mutual authentication scheme based on elliptic curve cryptography (ECC) to enhance patient medication safety. Our scheme can achieve security requirements and overcome various attacks existing in other schemes. In addition, our scheme has better performance in terms of computational cost and communication overhead. Therefore, the proposed scheme is well suitable for patient medication systems.

  18. Guideline on in-service testing (IST) of ECCS for nuclear power stations in Japan

    International Nuclear Information System (INIS)

    Yamashita, N.; Honjin, M.; Yamazaki, M.; Iwami, H.

    2001-01-01

    In Japan, METI (Ministry of Economy, Trade and Industry) periodic inspections are conducted every 13 months in accordance with the EUIL (Electric Utility Industry Law) for light water reactors. On the other hand, during operation, many kinds of function tests are conducted in accordance with Technical Specifications or utilities voluntary test procedures. However, these maintenance activities during outages are in other respects considered too costly and more than necessary because of its predetermined maintenance interval and its old-fashioned full scope maintenance menu. In these circumstances, the ASME O and M Codes and Standards, which are applied to nuclear power plants in the United States, came to be one of the issues to be considered among Japanese utilities. This is because the ASME O and M Codes and Standards, which are developed to verify the operational readiness of equipment or systems by condition based maintenance or performance testing without overhauls, will be considered to suggest a rational alternative to our existing maintenance activities. Because there had been no standard for function tests other than the METI inspection procedures in Japan, activities started for the development of Japanese Operation and Maintenance Guideline (hereinafter called the Japanese OM Guideline or the Guideline) for function tests and condition monitoring. The Japanese OM Guideline is not proclaimed for regulatory use, but the long-term objective is to provide a substantial basis to change the current maintenance activities including regulatory inspection. The Guideline is composed of five parts, which are general requirements, pumps, valves, snubbers and ECCS systems. This paper gives a summary of the ECCS part of the Japanese OM Guideline, in particular, focusing on the differences between the Guideline and the ASME O and M Standards, and topics or discussion during their establishment. (author)

  19. Performance-based ECCS cladding acceptance criteria: A new simulation approach

    International Nuclear Information System (INIS)

    Zoino, A.; Alfonsi, A.; Rabiti, C.; Szilard, R.H.; Giannetti, F.; Caruso, G.

    2017-01-01

    Highlights: • A new methodology to demonstrate compliance with the new ECCS acceptance criteria is described. • A wide spectrum of fuel rod initial burnup states can be analysed in the design phase. • The coupled suite PHISICS/RELAP5-3D has been used in the analyses. • A demo simulation of the equilibrium cycle, load-following and a LOCA analysis has been performed. - Abstract: The U.S. Nuclear Regulatory Commission is currently proposing rulemaking to revise the Loss Of Coolant Accident (LOCA) and therefore the Emergency Core Cooling System (ECCS) acceptance criteria, to include the effects of higher burnup on cladding performance as well as to address other technical issues. As motivated by the new rule, the need to use advanced cladding designs may be a result. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost, as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently, there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin. The study here presented has been part of a big project used to investigate technical issues and approaches for future industrial applications within the Risk-Informed Safety Margin Characterization (RISMC) Pathway. Specifically, the primary aim of this study is to lay out a roadmap to demonstrate the application of the new methodology. The present analysis shows a simplified version of the methodology of an industrial application on the Core Design and the Multi-Cycle Analysis.

  20. Incorporating Indigenous Knowledge and Practice into ECCE: A Comparison of Programs in The Gambia, Senegal and Mali

    Science.gov (United States)

    Soudee, Alicia Ranck

    2009-01-01

    Early Childhood Development (ECD) has emerged as a theme in international and African dialogue on education in recent years. UNESCO's Division of Basic Education Early Childhood promotes an integrated approach to Early Childhood Care and Education (ECCE) policy development and review. The study examines how this is implemented in three West…

  1. Simultaneous algae-polluted water treatment and electricity generation using a biocathode-coupled electrocoagulation cell (bio-ECC).

    Science.gov (United States)

    Dong, Yue; Qu, Youpeng; Li, Chao; Han, Xiaoyu; Ambuchi, John J; Liu, Junfeng; Yu, Yanling; Feng, Yujie

    2017-10-15

    How to utilize electrocoagulation (EC) technology for algae-polluted water treatment in an energy-efficient manner remains a critical challenge for its widespread application. Herein, a novel biocathode-coupled electrocoagulation cell (bio-ECC) with sacrificial iron anode and nitrifying biocathode was developed. Under different solution conductivities (2.33±0.25mScm -1 and 4.94±0.55mScm -1 ), the bio-ECC achieved almost complete removal of algae cells. The maximum power densities of 8.41 and 11.33Wm -3 at corresponding current densities of 48.03Am -3 and 66.26Am -3 were obtained, with the positive energy balance of 4.52 and 7.44Wm -3 . In addition, the bio-ECC exhibited excellent NH 4 + -N removal performance with the nitrogen removal rates of 7.28mgL -1 h -1 and 6.77mgL -1 h -1 in cathode chamber, indicating the superiority of bio-ECC in NH 4 + -N removal. Pyrosequencing revealed that nitrifiers including Nitrospira, Nitrobacter, Nitrosococcus, and Nitrosomonas were enriched in biocathode. The removal mechanisms of algae in anode chamber were also explored by AFM and SEM-EDX tests. These results provide a proof-of-concept study of transferring energy-intensive EC process into an energy-neutral process with high-efficiency algae removal and electricity recovery. Copyright © 2017. Published by Elsevier B.V.

  2. Simulation of strain-hardening in ECC uniaxial test specimen by use of a damage mechanics formulation

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  3. Investigation of break location effects on thermal-hydraulics during intermediate break loss-of-coolant accident experiments at ROSA-III

    International Nuclear Information System (INIS)

    Koizumi, Yasuo; Tasaka, Kanji

    1986-01-01

    The rig of safety assessment (ROSA)-III facility is a volumetrically scaled (1/424) boiling water reactor (BWR/6) system with an electrically heated core designed for integral loss-of-coolant accident (LOCA) and emergency core cooling system (ECCS) tests. Break location effects on thermal-hydraulics during intermediate LOCAs were investigated by using four experiments at the ROSA-III, the 15 and 25 % main recirculation pump suction line break (MRPS-B) experiments, the 21 % single-ended jet pump drive line break (JPD-B) experiment and the 15 % main steam line break (MSL-B) experiment. Water injection from the high pressure core spray (HPCS) was not used in any of the experiments. Failure of ECCS actuation by the high containment pressure was also assumed in the tests. In the MRPS-B experiments, the discharge flow turned from low quality fluid to high quality fluid when the downcomer water level dropped to the main recirculation line outlet elevation, which suppressed coolant loss from the vessel and the core. In the JPD-B experiment, the jet pump drive nozzle was covered with low quality fluid and low quality fluid discharge continued even after the downcomer water level reached the jet pump suction elevation. Low quality fluid discharge ceased after the ADS actuation. It suggestes that the JPD-B LOCA has the possibility of causing larger and more severe core dryout and cladding temperature excursion than the MRPS-B LOCA. The MSL-B LOCA was characterized by mixture level swell in the downcomer and the core. The core mixture level swell resulted in the much later core dryout initiation than that in the MRPS-B LOCA, however, ECCS actuation was also delayed because of slow downcomer water level drop. (author)

  4. Parametric study of the potential for BWR ECCS strainer blockage due to LOCA generated debris. Final report

    International Nuclear Information System (INIS)

    Zigler, G.; Brideau, J.; Rao, D.V.; Shaffer, C.; Souto, F.; Thomas, W.

    1995-10-01

    This report documents a plant-specific study for a BWR/4 with a Mark I containment that evaluated the potential for LOCA generated debris and the probability of losing long term recirculation capability due ECCS pump suction strainer blockage. The major elements of this study were: (1) acquisition of detailed piping layouts and installed insulation details for a reference BWR; (2) analysis of plant specific piping weld failure probabilities to estimate the LOCA frequency; (3) development of an insulation and other debris generation and drywell transport models for the reference BWR; (4) modeling of debris transport in the suppression pool; (5) development of strainer blockage head loss models for estimating loss of NPSH margin; (6) estimation of core damage frequency attributable to loss of ECCS recirculation capability following a LOCA. Elements 2 through 5 were combined into a computer code, BLOCKAGE 2.3. A point estimate of overall DEGB pipe break frequency (per Rx-year) of 1.59E-04 was calculated for the reference plant, with a corresponding overall ECCS loss of NPSH frequency (per Rx-year) of 1.58E-04. The calculated point estimate of core damage frequency (per Rx-year) due to blockage related accident sequences for the reference BWR ranged from 4.2E-06 to 2.5E-05. The results of this study show that unacceptable strainer blockage and loss of NPSH margin can occur within the first few minutes after ECCS pumps achieve maximum flows when the ECCS strainers are exposed to LOCA generated fibrous debris in the presence of particulates (sludge, paint chips, concrete dust). Generic or unconditional extrapolation of these reference plant calculated results should not be undertaken

  5. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  6. Comparison of temperature estimates from heat transport model and electrical resistivity tomography during a shallow heat injection and storage experiment

    OpenAIRE

    Hermans, Thomas; Daoudi, Moubarak; Vandenbohede, Alexander; Robert, Tanguy; Caterina, David; Nguyen, Frédéric

    2012-01-01

    Groundwater resources are increasingly used around the world as geothermal systems. Understanding physical processes and quantification of parameters determining heat transport in porous media is therefore important. Geophysical methods may be useful in order to yield additional information with greater coverage than conventional wells. We report a heat transport study during a shallow heat injection and storage field test. Heated water (about 50°C) was injected for 6 days at the rate of 80 l...

  7. Subcutaneous injection of thallium-201 chloride and gallium-67 citrate at acupuncture point K-3; An animal experiment and human-being study

    Energy Technology Data Exchange (ETDEWEB)

    Johg, Shiang-Bin; Wu, Chung-Chieng; Chen, Ming-Feng; Wu, Sheng-Nan (Kaohsiung Medical Coll., Taiwan (China))

    1992-09-01

    Subcutaneous (SC) injection of [sup 99m]Tc pertechnetate ([sup 99m]Tc) at acupuncture points K-3 is a new method of lower-limb radionuclide venography. To investigate the mechanism of absorption of [sup 99m]Tc from SC injected sites into vascular system, various radioisotopes such as [sup 201]Tl chloride ([sup 201]Tl) and [sup 67]Ga citrate ([sup 67]Ga) were SC injected at K-3 points in animal and human-beings experiments. It was found that [sup 99m]Tc and [sup 201]Tl were absorbed rapidly from K-3 points through venous system and into whole body soft tissue. However, [sup 67]Ga with a larger effective ionic radius than [sup 201]Tl was not absorbed throughout the observation of 5 minutes. Furthermore, intravenous administration of digitalis, a Na[sup +]-K[sup +] pump blocker, did not inhibit the absorption of [sup 99m]Tc and [sup 201]Tl after SC injection at K-3 points. These results suggest that absorption of radionuclides on SC injection at K-3 points is mainly through the passive pathway of diffusion rather than the active transport, and the effective ionic radius may be a major factor influencing the absorption rate of the radionuclides. (author).

  8. Endoscopic treatment of vesicoureteral reflux in children with subureteral dextranomer/hyaluronic acid injection: a single-centre, 7-year experience

    Science.gov (United States)

    Biočíc, Mihovil; Todoríc, Jakov; Budimir, Dražen; Roíc, Andrea Cvitkovíc; Pogorelíc, Zenon; Juríc, Ivo; Šušnjar, Tomislav

    2012-01-01

    Background The goals of medical intervention in patients with vesicoureteral reflux are to allow normal renal growth, prevent infections and pyelonephritis, and prevent renal failure. We present our experience with endoscopic treatment of vesicoureteral reflux in children by subureteral dextranomer/hyaluronic acid copolymer injection. Methods Under cystoscopic guidance, dextranomer/hyaluronic acid copolymer underneath the intravesical portion of the ureter in a subureteral or submucosal location was injected in patients undergoing endoscopic correction of vesicoureteral reflux. Results A total of 282 patients (120 boys and 162 girls) underwent the procedure. There were 396 refluxed ureters altogether. The mean age of patients was 4.9 years. The mean overall follow-up period was 44 months. Among the 396 ureters treated, 76% were cured with a single injection. A second and third injection raised the cure rate to 93% and 94%, respectively. Twenty-two (6%) ureters failed all 3 injections, and were converted to open surgery. Conclusion Endoscopic treatment of vesicoureteral reflux can be recommended as a first-line therapy for most cases of vesicoureteral reflux, because of the short hospital stay, absence of complications and the high success rate. PMID:22854114

  9. Failure Mode and Effects Analysis (FMEA) of the Emergency Core Cooling System (ECCS) for a Westinghouse type 312, three loop pressurized water reactor

    International Nuclear Information System (INIS)

    Shopsky, W.E.

    1977-01-01

    The Emergency Core Cooling System (ECCS) is a Safeguards System designed to cool the core in the unlikely event of a Loss-of-Coolant Accident (LOCA) in the primary reactor coolant system as well as to provide additional shutdown capability following a steam break accident. The system is designed for a high reliability of providing emergency coolant and shutdown reactivity to the core for all anticipated occurrences of such accidents. The ECCS by performing its intended function assures that fuel and clad damage is minimized during accident conditions thus reducing release of fission products from the fuel. The ECCS is designed to perform its function despite sustaining a single failure by the judicious use of equipment and flow path redundancy within and outside the containment structure. By the use of an analytic tool, a Failure Mode and Effects Analysis (FMEA), it is shown that the ECCS is in compliance with the Single Failure Criterion established for active failures of fluid systems during short and long term cooling of the reactor core following a LOCA or steam break accident. An analysis was also performed with regards to passive failure of ECCS components during long-term cooling of the core following an accident. The design of the ECCS was verified as being able to tolerate a single passive failure during long-term cooling of the reactor core following an accident. The FMEA conducted qualitatively demonstrates the reliability of the ECCS (concerning active components) to perform its intended safety function

  10. Analysis of emergency core cooling capability of direct vessel vertical injection using CFX

    International Nuclear Information System (INIS)

    Yoon, Sang H.; Yu, Yong H.; Suh, Kune Y.

    2003-01-01

    More reliable and efficient safety injection system is of utmost importance in the design of advanced reactors such as the APR1400 (Advanced Power Reactor 1400 MWe). In this work, a new idea is proposed to inject the Emergency Core Cooling (ECC) water utilizing a dedicated nozzle with a vertically downward elbow. The Direct Vessel Injection (DVI) system is located horizontally above the cold leg in the APR1400. However, the horizontal injection method may not always satisfy the ECC penetration requirement into the core on account of rather involved multidimensional thermal and hydraulic phenomena occurring in the annular reactor downcomer such as bypass, impingement, entrainment and sweepout, condensation oscillation, etc. Thus, a novel concept is called for from the reactor safety point of view. The Direct Vessel Vertical Injection (DVVI) system is one of these efforts to penetrate as much the ECC water through the downcomer into the core as is practically achievable. The DVVI system can increase the momentum of the downward flow, thus minimizing the effect of water impingement on the core barrel and the direct bypass though the break. To support the claim of increased downward momentum of flow in the DVVI system, computational fluid dynamics analyses were performed using CFX. The new concept of the DVVI system, which can certainly help increase the core thermal margin, is found to be more efficient than DVI. If the structural problem in the manufacturing process is properly solved, this concept can safely be applied in the advanced nuclear reactor design

  11. Design process of the nanofluid injection mechanism in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Bang In Choel

    2011-01-01

    Full Text Available Abstract Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs. This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner.

  12. Long-term Dose Stability of OnabotulinumtoxinA Injection for Adductor Spasmodic Dysphonia: A 19-Year Single Institution Experience

    Directory of Open Access Journals (Sweden)

    Paul Paddle

    2017-11-01

    Full Text Available ObjectivesAdductor spasmodic dysphonia (AdSD is a focal dystonia predominantly involving the laryngeal adductor muscles. AdSD is reported to be a largely non-progressive neurological disorder, though fluctuations in symptom severity do occur. Repeated laryngeal onabotulinumtoxinA (BTX-A injections are the primary management for AdSD. A number of studies have demonstrated long-term dose stability as evidence of this long-term disease stability.MethodsA retrospective review was performed on all patients undergoing BTX-A injections for AdSD from April 1994 to September 2013 by a single laryngologist at a tertiary referral laryngology center. Patient demographics, injection doses, use of diazepam and/or lidocaine, and self-reported vocal function were recorded. Multiple linear regression analyses were performed.Results83 patients underwent a total of 1,168 injections over 19 years. The mean starting dose was 2.35 MU (0.79 SD. The mean long-term dose was 2.36 MU (0.79 SD. After adjusting for confounders, the change in the relative dose of BTX-A, with every year elapsed since initial dose was 0.13% (95% confidence interval −0.31 to 0.57%, p = 0.568.ConclusionBTX-A dose is stable over time in our large cohort of patients treated with bilateral thyroarytenoid injections for AdSD.

  13. Numerical simulation of boron injection in a BWR

    Energy Technology Data Exchange (ETDEWEB)

    Tinoco, Hernan, E-mail: htb@forsmark.vattenfall.s [Forsmarks Kraftgrupp AB, SE-742 03 Osthammar (Sweden); Buchwald, Przemyslaw [Reactor Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Frid, Wiktor, E-mail: wiktor@reactor.sci.kth.s [Reactor Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden)

    2010-02-15

    The present study constitutes a first step to understand the process of boron injection, transport and mixing in a BWR. It consists of transient CFD simulations of boron injection in a model of the downcomer of Forsmark's Unit 3 containing about 6 million elements. The two cases studied are unintentional start of boron injection under normal operation and loss of offsite power with partial ATWS leaving 10% of the core power uncontrolled. The flow conditions of the second case are defined by means of an analysis with RELAP5, assuming boron injection start directly after the first ECCS injection. Recent publications show that meaningful conservative results may be obtained for boron or thermal mixing in PWRs with grids as coarse as that utilized here, provided that higher order discretization schemes are used to minimize numerical diffusion. The obtained results indicate an apparently strong influence of the scenario in the behavior of the injection process. The normal operation simulation shows that virtually all boron solution flows down to the Main Recirculation Pump inlet located directly below the boron inlet nozzle. The loss of offsite power simulation shows initially a spread of the boron solution over the entire sectional area of the lower part of the downcomer filled with colder water. This remaining effect of the ECCS injection lasts until all this water has left the downcomer. Above this region, the boron injection jet develops in a vertical streak, eventually resembling the injection of the normal operation scenario. Due to the initial spread, this boron injection will probably cause larger temporal and spatial concentration variations in the core. In both cases, these variations may cause reactivity transients and fuel damage due to local power escalation. To settle this issue, an analysis using an extended model containing the downcomer, the MRPs and the Lower Plenum will be carried out. Also, the simulation time will be extended to a scale of

  14. Numerical simulation of boron injection in a BWR

    International Nuclear Information System (INIS)

    Tinoco, Hernan; Buchwald, Przemyslaw; Frid, Wiktor

    2010-01-01

    The present study constitutes a first step to understand the process of boron injection, transport and mixing in a BWR. It consists of transient CFD simulations of boron injection in a model of the downcomer of Forsmark's Unit 3 containing about 6 million elements. The two cases studied are unintentional start of boron injection under normal operation and loss of offsite power with partial ATWS leaving 10% of the core power uncontrolled. The flow conditions of the second case are defined by means of an analysis with RELAP5, assuming boron injection start directly after the first ECCS injection. Recent publications show that meaningful conservative results may be obtained for boron or thermal mixing in PWRs with grids as coarse as that utilized here, provided that higher order discretization schemes are used to minimize numerical diffusion. The obtained results indicate an apparently strong influence of the scenario in the behavior of the injection process. The normal operation simulation shows that virtually all boron solution flows down to the Main Recirculation Pump inlet located directly below the boron inlet nozzle. The loss of offsite power simulation shows initially a spread of the boron solution over the entire sectional area of the lower part of the downcomer filled with colder water. This remaining effect of the ECCS injection lasts until all this water has left the downcomer. Above this region, the boron injection jet develops in a vertical streak, eventually resembling the injection of the normal operation scenario. Due to the initial spread, this boron injection will probably cause larger temporal and spatial concentration variations in the core. In both cases, these variations may cause reactivity transients and fuel damage due to local power escalation. To settle this issue, an analysis using an extended model containing the downcomer, the MRPs and the Lower Plenum will be carried out. Also, the simulation time will be extended to a scale of several

  15. Dynamic investigation of nutrient consumption and injection strategy in microbial enhanced oil recovery (MEOR) by means of large-scale experiments.

    Science.gov (United States)

    Song, Zhiyong; Zhu, Weiyao; Sun, Gangzheng; Blanckaert, Koen

    2015-08-01

    Microbial enhanced oil recovery (MEOR) depends on the in situ microbial activity to release trapped oil in reservoirs. In practice, undesired consumption is a universal phenomenon but cannot be observed effectively in small-scale physical simulations due to the scale effect. The present paper investigates the dynamics of oil recovery, biomass and nutrient consumption in a series of flooding experiments in a dedicated large-scale sand-pack column. First, control experiments of nutrient transportation with and without microbial consumption were conducted, which characterized the nutrient loss during transportation. Then, a standard microbial flooding experiment was performed recovering additional oil (4.9 % Original Oil in Place, OOIP), during which microbial activity mostly occurred upstream, where oil saturation declined earlier and steeper than downstream in the column. Subsequently, more oil remained downstream due to nutrient shortage. Finally, further research was conducted to enhance the ultimate recovery by optimizing the injection strategy. An extra 3.5 % OOIP was recovered when the nutrients were injected in the middle of the column, and another additional 11.9 % OOIP were recovered by altering the timing of nutrient injection.

  16. Investigation of process parameters influence on flash formation in injection moulding of polymer micro features through design of experiments

    DEFF Research Database (Denmark)

    Eladl, Abdelkhalik; Tosello, Guido; Mostafa, Rania

    Micro injection moulding is one of the key technologies for micro manufacture due to its mass-production capability and relatively low component cost. Flash defects are among the most critical issues in the replication of micro features and constitute a manufacturing constrain in applying injecti...

  17. Perspectives and experiences of Dutch multiple sclerosis patients and multiple sclerosis-specialized neurologists on injectable disease-modifying treatment

    NARCIS (Netherlands)

    Visser, Leo H.; Heerings, Marco A.; Jongen, Peter J.; van der Hiele, Karin

    2016-01-01

    Background: The adherence to treatment with injectable disease-modifying drugs (DMDs) in multiple sclerosis (MS) may benefit from adequate information provision and management of expectations. The communication between patients and physicians is very important in this respect. The current study

  18. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    Science.gov (United States)

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  19. Estimated net value and uncertainty for automating ECCS switchover at PWRs

    International Nuclear Information System (INIS)

    Walsh, B.; Brideau, J.; Comes, L.; Darby, J.; Guttmann, H.; Sciacca, F.; Souto, F.; Thomas, W.; Zigler, G.

    1996-02-01

    Question for resolution of Generic Safety Issue No. 24 is whether or not PWRs that currently rely on a manual system for ECCS switchover to recirculation should be required to install an automatic system. Risk estimates are obtained by reevaluating the contributions to core damage frequencies (CDFs) associated with failures of manual and semiautomatic switchover at a representative PWR. This study considers each separate instruction of the corresponding emergency operating procedures (EOPs), the mechanism for each control, and the relation of each control to its neighbors. Important contributions to CDF include human errors that result in completely coupled failure of both trains and failure to enter the required EOP. It is found that changeover to a semiautomatic system is not justified on the basis of cost-benefit analysis: going from a manual to a semiautomatic system reduces the CDF by 1.7 x 10 -5 per reactor-year, but the probability that the net cost of the modification being less than $1, 000 per person-rem is about 20% without license renewal. Scoping analyses, using optimist assumptions, were performed for a changeover to a semiautomatic system with automatic actuation and to a fully automatic system; in these cases the probability of a net cost being less than $1,000/person-rem is about 50% without license renewal and over 95% with license renewal

  20. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    Science.gov (United States)

    Mehmood, Zahid; Chen, Gongliang; Li, Jianhua; Li, Linsen; Alzahrani, Bander

    2017-01-01

    Over the past few years, Session Initiation Protocol (SIP) is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  1. A robust ECC based mutual authentication protocol with anonymity for session initiation protocol.

    Directory of Open Access Journals (Sweden)

    Zahid Mehmood

    Full Text Available Over the past few years, Session Initiation Protocol (SIP is found as a substantial application-layer protocol for the multimedia services. It is extensively used for managing, altering, terminating and distributing the multimedia sessions. Authentication plays a pivotal role in SIP environment. Currently, Lu et al. presented an authentication protocol for SIP and profess that newly proposed protocol is protected against all the familiar attacks. However, the detailed analysis describes that the Lu et al.'s protocol is exposed against server masquerading attack and user's masquerading attack. Moreover, it also fails to protect the user's identity as well as it possesses incorrect login and authentication phase. In order to establish a suitable and efficient protocol, having ability to overcome all these discrepancies, a robust ECC-based novel mutual authentication mechanism with anonymity for SIP is presented in this manuscript. The improved protocol contains an explicit parameter for user to cope the issues of security and correctness and is found to be more secure and relatively effective to protect the user's privacy, user's masquerading and server masquerading as it is verified through the comprehensive formal and informal security analysis.

  2. Risk-based assessment of the allowable outage times for the unit 1 leningrad nuclear power plant ECCS components

    International Nuclear Information System (INIS)

    Koukhar, Sergey; Vinnikov, Bronislav

    2009-01-01

    Present paper describes a method for risk - informed assessment of the Allowable Outage Times (AOTs). The AOT is the time, when components of a safety system allowed to be out of service during power operation or during shutdown operation off a plant. If the components are not restored during the time, the plant in operation must be shut down or the plant in a given shutdown mode has to go to safer shutdown mode. Application of the method is also provided for the equipment of the Unit 1 Leningrad NPP ECCS components. For solution of the problem it is necessary to carry out two series of computations using a Living PSA model, level 1. In the first series of the computations the core damage frequency (CDFb) for the base configuration of the plant is determined (there is no equipment out of service). Here the symbol 'b' means the base configuration of a plant. In the second series of the computations the core damage frequency (CDFi) for the configuration of the plant with the component (which is out of service) is calculated. That is here CDFi is determined for the failure probability of the component equal to 1.0 (component 'i' is unavailable). Then it is necessary to determine so called Risk Increase Factor (RIF) using the following ratio: RIFi = CDFi / CDFb. At last the AOT is calculated with the help of the ratio: AOTi = Tppr / RIFi, where Tppr is a period of time between two Planned Preventive Repairs (PPRs). 1. Using the risk based approach the AOTs were calculated for a set of the components of the Unit 1 Leningrad NPP ECCS components. 2. The main conclusion from the analysis is that the current deterministic AOTs for the ECCS components are conservative and should be extended. 3. The risk based extension of the AOTs for the ECCS components can prevent the Unit 1 Leningrad NPP to enter into the operating modes with increased risk. (author)

  3. Comprehensive Oral Health Care to Reduce the Incidence of Severe Early Childhood Caries (s-ECC) in Urban China.

    Science.gov (United States)

    Si, Yan; Guo, Yan; Yuan, Chao; Xu, Tao; Zheng, Shu Guo

    2016-03-01

    To explore the effectiveness of comprehensive oral health care to reduce the caries incidence for children with severe early childhood caries (s-ECC) in an urban area in China. A total of 357 children aged 3 to 4 years old and diagnosed with s-ECC were recruited in this randomised controlled, single-blinded clinical trial for 1 year. Children of two different kindergarten classes were enrolled in this study and randomly divided into a test group (205 children) and a control group (152 children). The test group received comprehensive oral health care, which included: oral health examination, oral health education, topical fluoride application and dental treatment, and the children in the control group only received the oral health examination. The evaluation of the oral health questionnaire for parents was also performed. An evaluation was carried out at the time of recruitment and 1 year later to explore the effectiveness of the comprehensive oral health care model. The differences in decayed teeth (dt), decayed tooth surfaces (ds), filled teeth (ft), filled tooth surfaces (fs) and the ratio of ft /(dt + ft) between the two groups were statistically significant (P comprehensive oral health care program reduces and prevents caries amongst children with s-ECC.

  4. Comparison of allele frequency for HLA-DR and HLA-DQ between patients with ECC and caries-free children

    OpenAIRE

    Bagherian A; Nematollahi H; Afshari J; Moheghi N

    2008-01-01

    Background: Early childhood caries (ECC) is one of the most common diseases of childhood. The etiology of ECC is multifactorial and both genetic and environmental factors play important roles in the pathogenesis of the disease. Genetic variations in the hosts may contribute to changes in the risk for dental caries. Genetic factors such as human leukocyte antigen (HLA) have recently been suggested as a predisposing factor. Aim: The aim of this study was to look for an association between HLA-D...

  5. Optimizing CT angiography in patients with Fontan physiology: single-center experience of dual-site power injection

    International Nuclear Information System (INIS)

    Sandler, K.L.; Markham, L.W.; Mah, M.L.; Byrum, E.P.; Williams, J.R.

    2014-01-01

    Aim: To identify adult patients with single-ventricle congenital heart disease and Fontan procedure palliation who have been misdiagnosed with or incompletely evaluated for pulmonary embolism. Additionally, this study was designed to demonstrate that simultaneous, dual-injection of contrast medium into an upper and lower extremity vein is superior to single-injection protocols for CT angiography (CTA) of the chest in this population. Materials and methods: Patients included in the study were retrospectively selected from the Adult Congenital Heart Disease (ACHD) database. Search criteria included history of Fontan palliation and available chest CT examination. Patients were evaluated for (1) type of congenital heart disease and prior operations;(2) indication for initial CT evaluation;(3) route of contrast medium administration for the initial CT examination and resulting diagnosis;(4) whether or not anticoagulation therapy was initiated; and (5) final diagnosis and treatment plan. Results: The query of the ACHD database resulted in 28 individuals or patients with Fontan palliation (superior and inferior venae cavae anastomosed to the pulmonary arteries). Of these, 19 patients with Fontan physiology underwent CTA of the pulmonary circulation, and 17 had suboptimal imaging studies. Unfortunately, seven of these 17 patients (41%) were started on anticoagulation therapy due to a diagnosis of pulmonary embolism that was later excluded. Conclusion: Patients with single-ventricle/Fontan physiology are at risk of thromboembolic disease. Therefore, studies evaluating their complex anatomy must be performed with the optimal imaging protocol to ensure diagnostic accuracy, which is best achieved with dual-injection of an upper and lower extremity central vein. - Highlights: • The adult congenital heart disease population is growing. • Many of these patients have single ventricle/Fontan physiology. • Patients with Fontan physiology are at increased risk for

  6. Simulation of injector dynamics during steady inductive helicity injection current drive in the HIT-SI experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C., E-mail: hansec@uw.edu [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Columbia University, New York, New York 10027 (United States); Marklin, G. [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Victor, B. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); Akcay, C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Jarboe, T. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); PSI-Center, University of Washington, Seattle, Washington 98195 (United States)

    2015-04-15

    We present simulations of inductive helicity injection in the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) device that treats the entire plasma volume in a single dynamic MHD model. A new fully 3D numerical tool, the PSI-center TETrahedral mesh code, was developed that provides the geometric flexibility required for this investigation. Implementation of a zero-β Hall MHD model using PSI-TET will be presented including formulation of a new self-consistent magnetic boundary condition for the wall of the HIT-SI device. Results from simulations of HIT-SI are presented focusing on injector dynamics that are investigated numerically for the first time. Asymmetries in the plasma loading between the two helicity injectors and progression of field reversal in each injector are observed. Analysis indicates cross-coupling between injectors through confinement volume structures. Injector impedance is found to scale with toroidal current at fixed density, consistent with experimental observation. Comparison to experimental data with an injector drive frequency of 14.5 kHz shows good agreement with magnetic diagnostics. Global mode structures from Bi-Orthogonal decomposition agree well with experimental data for the first four modes.

  7. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  8. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  9. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  10. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  11. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  12. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  13. Comparison of allele frequency for HLA-DR and HLA-DQ between patients with ECC and caries-free children

    Directory of Open Access Journals (Sweden)

    Bagherian A

    2008-03-01

    Full Text Available Background: Early childhood caries (ECC is one of the most common diseases of childhood. The etiology of ECC is multifactorial and both genetic and environmental factors play important roles in the pathogenesis of the disease. Genetic variations in the hosts may contribute to changes in the risk for dental caries. Genetic factors such as human leukocyte antigen (HLA have recently been suggested as a predisposing factor. Aim: The aim of this study was to look for an association between HLA-DRB1 and HLA-DQB1 with ECC for developing new strategies for the diagnosis as well as the prevention of the disease. Design: In this study, we extracted the genomic DNAs from whole blood samples of 44 patients with ECC and 35 caries-free children by the salting-out method. We amplified the genomic DNA by PCR-SSP and then HLA-typing was performed for all alleles. Results: The results revealed a significant increase in the frequency of HLA-DRB1FNx0104 in the patient group (P = 0.019. The odds ratio for this allele was detected to be 10. The frequency of HLA-DQB1 alleles was not significantly different between the two groups. Conclusion: The above results suggest that HLA-DRB1FNx0104 is associated with the susceptibility to ECC. Thus HLA-DRB1FNx0104 detection as a molecular marker for early diagnosis of ECC may be recommended.

  14. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  15. Charge-exchange measurements of MHD activity during neutral beam injection in the Princeton Large Torus and the Poloidal Divertor Experiment

    International Nuclear Information System (INIS)

    Goldston, R.J.; Kaita, R.; Beiersdorfer, P.; Gammel, G.; Herndon, D.L.; McCune, D.C.; Meyerhofer, D.D.

    1986-07-01

    The horizontally scanning, multiangle charge-exchange analyzers on the Princeton Large Torus (PLT) and the Poloidal Divertor Experiment (PDX) were used to study the effects of MHD activity on the background ion distribution function and on the beam ion slowing-down process during high-power neutral injection. Sawtooth oscillations were observed in the fast ion flux on PLT and PDX, and measurements with neutral beams providing local neutral density enhancement indicate that ions are transported radially when these events occur. With near-perpendicular injection in PDX, at the lower toroidal fields necessary to maximize beta, rapid, repetitive bursts of greatly enhanced charge-exchange flux were observed. These are associated with the ''fishbone'' MHD instability, and a substantial depletion of the perpendicular slowing-down spectrum below the injection energy was seen. A simple phenomenological model for this loss mechanism was developed, and its use in simulation codes has been successful in providing good agreement with the data. The behavior and characteristics of this model are well matched by the direct theoretical calculations

  16. Prevalence and Characteristics of Abuse Experiences and Depression Symptoms among Injection Drug-Using Female Sex Workers in Mexico

    Directory of Open Access Journals (Sweden)

    Monica D. Ulibarri

    2013-01-01

    Full Text Available This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors—ever experiencing forced sex and forced sex in the context of sex work—were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.

  17. Prevalence and characteristics of abuse experiences and depression symptoms among injection drug-using female sex workers in Mexico.

    Science.gov (United States)

    Ulibarri, Monica D; Hiller, Sarah P; Lozada, Remedios; Rangel, M Gudelia; Stockman, Jamila K; Silverman, Jay G; Ojeda, Victoria D

    2013-01-01

    This mixed methods study examined the prevalence and characteristics of physical and sexual abuse and depression symptoms among 624 injection drug-using female sex workers (FSW-IDUs) in Tijuana and Ciudad Juarez, Mexico; a subset of 47 from Tijuana also underwent qualitative interviews. Linear regressions identified correlates of current depression symptoms. In the interviews, FSW-IDUs identified drug use as a method of coping with the trauma they experienced from abuse that occurred before and after age 18 and during the course of sex work. In a multivariate linear regression model, two factors-ever experiencing forced sex and forced sex in the context of sex work-were significantly associated with higher levels of depression symptoms. Our findings suggest the need for integrated mental health and drug abuse services for FSW-IDUs addressing history of trauma as well as for further research on violence revictimization in the context of sex work in Mexico.

  18. Sexual Behaviors, Experiences of Sexual Violence, and Substance Use among Women Who inject Drugs: Accessing Health and Prevention Services in Puerto Rico.

    Science.gov (United States)

    Collazo-Vargas, Erika M; Dodge, Brian; Herbenick, Debby; Guerra-Reyes, Lucia; Mowatt, Rasul; Otero-Cruz, Ilia M; Rodríguez-Díaz, Carlos

    2018-06-01

    People who inject drugs (PWID) face numerous gender-specific health risks, which increase their susceptibility to adverse outcomes, including violence. There is a need for research on female PWID to capture their unique experiences and understand behavioral and gender-based differences. This study aimed to understand which drug use and sexual behaviors are the most prevalent among female PWID accessing health services in Puerto Rico and to gather preliminary information on those individuals' experiences of sexual violence. Utilizing a transformative theoretical perspective, a mixed-methods study was conducted with a sample of 90 Puerto Rican women who reported recent (past 12 months) injection drug use (IDU) This manuscript focused on Phase 1, in which participants completed an interviewer-administered survey eliciting information about sexual behaviors, drug use, experiences of sexual violence, and access to healthcare services. Phase 2 involved an in-depth interview focused on sexual health and access to healthcare services. Female PWID were found to engage in a variety of sexual behaviors throughout their lifespans and at their most recent sexual events. There were significant differences across age groups for participants, those being time of most recent sexual event (p = 0.007), partner's sex (p = 0.039), relationship with partner (p = 0.023), contraception method used (p = 0.057), and reports of partner orgasm (p = 0.055). Over half of all participants reported having experienced sexual violence in their lifetime. This study extends the literature on PWID in Puerto Rico by underscoring the diversity of female PWID sexual experiences and needs while illustrating how those experiences are often mediated by drug use. The findings highlight the need for further research on female PWID in Puerto Rico to better develop programs that include sexual violence prevention as part of future interventions for this population.

  19. R&D Plan for RISMC Industry Application #1: ECCS/LOCA Cladding Acceptance Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Szilard, Ronaldo Henriques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Epiney, Aaron Simon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tu, Lei [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    The Nuclear Regulatory Commission (NRC) is finalizing a rulemaking change that would revise the requirements in 10 CFR 50.46. In the proposed new rulemaking, designated as 10 CFR 50.46c, the NRC proposes a fuel performance-based equivalent cladding reacted (ECR) criterion as a function of cladding hydrogen content before the accident (pre-transient) in order to include the effects of higher burnup on cladding performance as well as to address other technical issues. A loss of operational margin may result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee costs as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. The Idaho National Laboratory (INL) has initiated a project, as part of the DOE Light Water Reactor Sustainability Program (LWRS), to develop analytical capabilities to support the industry in the transition to the new rule. This project is called the Industry Application 1 (IA1) within the Risk-Informed Safety Margin Characterization (RISMC) Pathway of LWRS. The general idea behind the initiative is the development of an Integrated Evaluation Model (IEM). The motivation is to develop a multiphysics framework to analyze how uncertainties are propagated across the stream of physical disciplines and data involved, as well as how risks are evaluated in a LOCA safety analysis as regulated under 10 CFR 50.46c. This IEM is called LOTUS which stands for LOCA Toolkit for US, and it represents the LWRS Program’s response to the proposed new rule making. The focus of this report is to complete an R&D plan to describe the demonstration of the LOCA/ECCS RISMC Industry Application # 1 using the advanced RISMC Toolkit and methodologies. This report includes the description and development plan for a RISMC LOCA tool that fully couples advanced MOOSE tools already in development in order to characterize and optimize

  20. Feeding practice among 6-36 months old in Tanzania and Uganda: reliability and relationship with early childhood caries, ECC.

    Science.gov (United States)

    Masumo, Ray; Bardsen, Asgeir; Mashoto, Kijakazi; Åstrøm, Anne Nordrehaug

    2013-09-01

    To assess the reproducibility of caregivers' responses to dietary recall from birth and 24-h dietary recall with respect to infants' intake of sugared snacks and to assess whether those assessment methods provide comparable results for groups of infants. Re-test reliability and clinical covariates of time to first exposure of sugared snacks and time to termination of breastfeeding were also examined. It was hypothesized that time to first exposure/termination would vary according to socio-demographic profile and ECC. Interviews and clinical oral examinations were carried out in Kampala and Manyara, including 1221 and 816 child-caregiver pairs. Reproducibility was assessed using Cohen's kappa and Intra Class Correlation Coefficient, ICC. Adjusted Cox regression was used to model time to first exposure of sugared snacks and time to termination of breastfeeding. Cohen's kappa for intake of sugar items ranged from 0.40-1.0, with no differences observed between average intakes at test-re-test. Mean sugar score based on 24-h recall increased significantly by increasing quartiles of the sugar score based on recall from birth. Cox regression revealed that the odds ratio, OR, for early exposure to various sugared snacks and the ORs for early termination of breastfeeding were significantly smaller in infants with than without ECC. Fair-to-good reproducibility was established. Infant's sugar consumption emerge as early as 6 months of age. Survival of any breastfeeding and non-exposure to sugared snacks was most prolonged among infants with ECC. This has implications for interventions needed to improve feeding habits of infants and toddlers.

  1. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  2. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  3. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  4. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  5. Long-term results of percutaneous ethanol injection therapy for hepatocellular carcinoma in cirrhosis: a European experience

    International Nuclear Information System (INIS)

    Lencioni, R.; Pinto, F.; Armillotta, N.; Bassi, A.M.; Moretti, M.; Di Giulio, M.; Marchi, S.; Uliana, M.; Della Capanna, S.; Lencioni, M.; Bartolozzi, C.

    1997-01-01

    The objective of our work was to evaluate the long-term results of percutaneous ethanol injection (PEI) for the treatment of hepatocellular carcinoma (HCC) in patients with liver cirrhosis. A total of 184 cirrhotic patients with HCC underwent PEI as the only anticancer treatment over an 8-year period. Patients were followed after therapy by means of clinical examinations, laboratory tests, and US and CT studies performed at regular time intervals. Survival rates were determined according to the Kaplan-Meier method. The overall survival was 67% at 3 years, 41% at 5 years, and 19% at 7 years. The 3-, 5-, and 7-year survival rates of patients with single HCC≤3 cm (78, 54, and 28%, respectively) were significantly higher (p<0.01) than those of patients with single HCC of 3.1-5 cm (61, 32, and 16, respectively) or multiple HCCs (51, 21, and 0%, respectively). Survival of Child-Pugh A patients (79% at 3 years, 53% at 5 years, and 32% at 7 years) was significantly longer (p<0.01) than that of Child-Pugh B patients (50% at 3 years, 28% at 5 years, and 8% at 7 years). A selected group of 70 patients with Child-Pugh A cirrhosis and single HCC≤3 cm had a 7-year survival of 42%. Long-term survival of cirrhotic patients with HCC treated with PEI is comparable to that reported in published series of matched patients submitted to surgical resection. (orig.)

  6. Experience in ultrasonic gap measurement between calandria tubes and liquid injection shutdown systems nozzles in Bruce Nuclear Generating Station

    International Nuclear Information System (INIS)

    Abucay, R.C.; Mahil, K.S.; Goszczynski, J.J.

    1995-01-01

    The gaps between calandria tubes (CT) and Liquid Injection Shutdown System (LISS) nozzles at the Bruce Nuclear Generating Station ''A'' (Bruce A) are known to decrease with time due to radiation induced creep/sag of the calandria tubes. If this gap decreases to a point where the calandria tubes come into contact with the LISS nozzle, the calandria tubes could fail as a result of fretting damage. Proximity measurements were needed to verify the analytical models and ensure that CT/LISS nozzle contact does not occur earlier than predicted. The technique used was originally developed at Ontario Hydro Technologies (formerly Ontario Hydro Research Division) in the late seventies and put into practical use by Research and Productivity Council (RPC) of New Brunswick, who carried out similar measurements at Point Lepreau NGS in 1989 and 1991. The gap measurement was accomplished y inserting an inspection probe, containing four ultrasonic transducers (2 to measure gaps and 2 to check for probe tilt) and a Fredericks electrolytic potentiometer as a probe rotational sensor, inside LISS Nozzle number-sign 7. The ultrasonic measurements were fed to a system computer that was programmed to convert the readings into fully compensated gaps, taking into account moderator heavy water temperature and probe tilt. Since the measured gaps were found to be generally larger than predicted, the time to CT/LISS nozzle contact is now being re-evaluated and the planned LISS nozzle replacement will likely be deferred, resulting in considerable savings

  7. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  8. AN ANALYSIS OF STUDENTS’ SPEAKING ABILITY IN ENGLISH CONVERSATION CLUB (ECC PROGRAM AT THE 3rd SEMESTER

    Directory of Open Access Journals (Sweden)

    M. Fadhly Farhy Abbas

    2017-07-01

    Full Text Available This research is based on students’ speaking ability who had followed the EnglishConversation Club (ECC program especially for the third semester of English Department. Thepurpose of this study was to analyze the students’ speaking ability at the 3rd semester in the EnglishConversation Club FKIP UNILAK Pekanbaru. The type of the research was mixed method in typeof explanatory design. The number of participant was 53 students. The researcher used twoinstruments, those were test and interview. In analyzing the data, it used in descriptive statistics.The result of the analysis showed that the average score of 3rd semester students’ speaking abilitywas 45.42. It can be concluded that the students’ speaking ability was categorized into failed . Thescore of Standard Deviation was 7.02, Variance was 49.30, and Range was 36 points . It meansthat the students’ speaking ability was homogeneous. According to the Z-Score, it can be seen that49.06% students’ ability was higher than average and 50.94% students ability was below theaverage. In conclusion, the students’ ability in learning speaking English was failed, it had beenaffected by some factors, those were lack of vocabulary, grammar and motivation. It was supportedby the interview, eventhough the students’ perception to English Conversation Club (ECCprogram was positive, but in fact, the students’ frequency to speak English was seldom, they wereless practice speaking English everyday.Keywords : Speaking , English Conversation Club (ECC

  9. Parametric Effects of Debris Source, Environments, and Design Options on the Overall Performance of ECCS Recirculation Sump

    International Nuclear Information System (INIS)

    Park, Jong Woon; Kim, Chang Hyun

    2006-01-01

    A primary safety issue regarding long-term recirculation core cooling following a LOCA (Loss of Coolant Accident) is that LOCA-generated debris may be transported to the recirculation sump screen, resulting in adverse blockage on the sump screen and deterioration of available NPSH (Net Positive Suction Head) of ECCS (Emergency Core Cooling System). USNRC identified this as Generic Safety Issue (GSI) 191 and issued the Generic Letter 04-02 to resolve the issue. The GL required that all PWR owners perform an engineering assessment of their containment recirculation sumps to ensure they will not suffer from excessive blockage. The guidance report (GR) for PWR sump performance evaluation has been developed by NEI (Nuclear Energy Institute) and approved by the USNRC. In Korea, Korea Hydro and Nuclear Power Company (KHNP) is performing the assessment of Kori unit 1 and planning for remaining plants in the near future. The objective of the assessment is to derive required plant modifications including insulation, sump screen, etc. To derive the cost-effective modification items, we have to get insight on the parametric effects of plant conditions and design. Therefore, the general effects of debris source, containment environments and debris interceptor on the performance of ECCS recirculation sump with respect to head loss are parametrically investigated

  10. Validation of single-fluid and two-fluid magnetohydrodynamic models of the helicity injected torus spheromak experiment with the NIMROD code

    International Nuclear Information System (INIS)

    Akcay, Cihan; Victor, Brian S.; Jarboe, Thomas R.; Kim, Charlson C.

    2013-01-01

    We present a comparison study of 3-D pressureless resistive MHD (rMHD) and 3-D presureless two-fluid MHD models of the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI). HIT-SI is a current drive experiment that uses two geometrically asymmetric helicity injectors to generate and sustain toroidal plasmas. The comparable size of the collisionless ion skin depth d i to the resistive skin depth predicates the importance of the Hall term for HIT-SI. The simulations are run with NIMROD, an initial-value, 3-D extended MHD code. The modeled plasma density and temperature are assumed uniform and constant. The helicity injectors are modeled as oscillating normal magnetic and parallel electric field boundary conditions. The simulations use parameters that closely match those of the experiment. The simulation output is compared to the formation time, plasma current, and internal and surface magnetic fields. Results of the study indicate 2fl-MHD shows quantitative agreement with the experiment while rMHD only captures the qualitative features. The validity of each model is assessed based on how accurately it reproduces the global quantities as well as the temporal and spatial dependence of the measured magnetic fields. 2fl-MHD produces the current amplification (I tor /I inj ) and formation time τ f demonstrated by HIT-SI with similar internal magnetic fields. rMHD underestimates (I tor /I inj ) and exhibits much a longer τ f . Biorthogonal decomposition (BD), a powerful mathematical tool for reducing large data sets, is employed to quantify how well the simulations reproduce the measured surface magnetic fields without resorting to a probe-by-probe comparison. BD shows that 2fl-MHD captures the dominant surface magnetic structures and the temporal behavior of these features better than rMHD

  11. Multi-Scale Experiments to Evaluate Mobility Control Methods for Enhancing the Sweep Efficiency of Injected Subsurface Remediation Amendments

    Science.gov (United States)

    2010-08-01

    degrading or fermenting a larger and more complex molecule (such as the polymers involved in this work), but it is unknown if other microbes naturally...Jackson Lee in 2009 from a sludge holding tank at a beer brewery were also utilized in select microcosm experiments. These microbes (referred to as the...tested another derivative of the Environment 2 scenario, wherein the NBB anaerobes (capable of fermentation of large organic molecules) could

  12. MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

    Science.gov (United States)

    Arpinar, V E; Hamamura, M J; Degirmenci, E; Muftuler, L T

    2012-07-07

    Magnetic resonance electrical impedance tomography (MREIT) is a technique that produces images of conductivity in tissues and phantoms. In this technique, electrical currents are applied to an object and the resulting magnetic flux density is measured using magnetic resonance imaging (MRI) and the conductivity distribution is reconstructed using these MRI data. Currently, the technique is used in research environments, primarily studying phantoms and animals. In order to translate MREIT to clinical applications, strict safety standards need to be established, especially for safe current limits. However, there are currently no standards for safe current limits specific to MREIT. Until such standards are established, human MREIT applications need to conform to existing electrical safety standards in medical instrumentation, such as IEC601. This protocol limits patient auxiliary currents to 100 µA for low frequencies. However, published MREIT studies have utilized currents 10-400 times larger than this limit, bringing into question whether the clinical applications of MREIT are attainable under current standards. In this study, we investigated the feasibility of MREIT to accurately reconstruct the relative conductivity of a simple agarose phantom using 200 µA total injected current and tested the performance of two MREIT reconstruction algorithms. These reconstruction algorithms used are the iterative sensitivity matrix method (SMM) by Ider and Birgul (1998 Elektrik 6 215-25) with Tikhonov regularization and the harmonic B(Z) proposed by Oh et al (2003 Magn. Reason. Med. 50 875-8). The reconstruction techniques were tested at both 200 µA and 5 mA injected currents to investigate their noise sensitivity at low and high current conditions. It should be noted that 200 µA total injected current into a cylindrical phantom generates only 14.7 µA current in imaging slice. Similarly, 5 mA total injected current results in 367 µA in imaging slice. Total

  13. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  14. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  15. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  16. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  17. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  18. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  19. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  20. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  1. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  2. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  3. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  4. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  5. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  6. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  7. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  8. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  9. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  10. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  11. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  12. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  13. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  14. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  15. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  16. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  17. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  18. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  19. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  20. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  1. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  2. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  3. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  4. An anaerobic field injection experiment in a landfill leachate plume, Grindsted, Denmark: 2. Deduction of anaerobic (methanogenic, sulfate-, and Fe (III)-reducing) redox conditions

    Science.gov (United States)

    Albrechtsen, Hans-JøRgen; Bjerg, Poul L.; Ludvigsen, Liselotte; Rügge, Kirsten; Christensen, Thomas H.

    1999-04-01

    Redox conditions may be environmental factors which affect the fate of the xenobiotic organic compounds. Therefore the redox conditions were characterized in an anaerobic, leachate-contaminated aquifer 15-60 m downgradient from the Grindsted Landfill, Denmark, where an field injection experiment was carried out. Furthermore, the stability of the redox conditions spatially and over time were investigated, and different approaches to deduce the redox conditions were evaluated. The redox conditions were evaluated in a set of 20 sediment and groundwater samples taken from locations adjacent to the sediment samples. Samples were investigated with respect to groundwater chemistry, including hydrogen and volatile fatty acids (VFAs) and sediment geochemistry, and bioassays were performed. The groundwater chemistry, including redox sensitive species for a large number of samples, varied over time during the experimental period of 924 days owing to variations in the leachate from the landfill. However, no indication of change in the redox environment resulting from the field injection experiment or natural variation was observed in the individual sampling points. The methane, Fe(II), hydrogen, and VFA groundwater chemistry parameters strongly indicated a Fe(III)-reducing environment. This was further supported by the bioassays, although methane production and sulfate-reduction were also observed in a few samples close to the landfill. On the basis of the calculated carbon conversion, Fe(III) was the dominant electron acceptor in the region of the aquifer, which was investigated. Because of the complexity of a landfill leachate plume, several redox processes may occur simultaneously, and an array of methods must be applied for redox characterization in such multicomponent systems.

  5. High-Intensity Radiated Field Fault-Injection Experiment for a Fault-Tolerant Distributed Communication System

    Science.gov (United States)

    Yates, Amy M.; Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Gonzalez, Oscar R.; Gray, W. Steven

    2010-01-01

    Safety-critical distributed flight control systems require robustness in the presence of faults. In general, these systems consist of a number of input/output (I/O) and computation nodes interacting through a fault-tolerant data communication system. The communication system transfers sensor data and control commands and can handle most faults under typical operating conditions. However, the performance of the closed-loop system can be adversely affected as a result of operating in harsh environments. In particular, High-Intensity Radiated Field (HIRF) environments have the potential to cause random fault manifestations in individual avionic components and to generate simultaneous system-wide communication faults that overwhelm existing fault management mechanisms. This paper presents the design of an experiment conducted at the NASA Langley Research Center's HIRF Laboratory to statistically characterize the faults that a HIRF environment can trigger on a single node of a distributed flight control system.

  6. The Mochi LabJet Experiment for Measurements of Canonical Helicity Injection in a Laboratory Astrophysical Jet

    Science.gov (United States)

    You, Setthivoine; von der Linden, Jens; Sander Lavine, Eric; Carroll, Evan Grant; Card, Alexander; Quinley, Morgan; Azuara-Rosales, Manuel

    2018-06-01

    The Mochi device is a new pulsed power plasma experiment designed to produce long, collimated, stable, magnetized plasma jets when set up in the LabJet configuration. The LabJet configuration aims to simulate an astrophysical jet in the laboratory by mimicking an accretion disk threaded by a poloidal magnetic field with concentric planar electrodes in front of a solenoidal coil. The unique setup consists of three electrodes, each with azimuthally symmetric gas slits. Two of the electrodes are biased independently with respect to the third electrode to control the radial electric field profile across the poloidal bias magnetic field. This design approximates a shear azimuthal rotation profile in an accretion disk. The azimuthally symmetric gas slits provide a continuously symmetric mass source at the footpoint of the plasma jet, so any azimuthal rotation of the plasma jet is not hindered by a discrete number of gas holes. The initial set of diagnostics consists of current Rogowski coils, voltage probes, magnetic field probe arrays, an interferometer and ion Doppler spectroscopy, supplemented by a fast ion gauge and a retarding grid energy analyzer. The measured parameters of the first plasmas are ∼1022 m‑3, ∼0.4 T, and 5–25 eV, with velocities of ∼20–80 km s‑1. The combination of a controllable electric field profile, a flared poloidal magnetic field, and azimuthally symmetric mass sources in the experiment successfully produces short-lived (∼10 μs, ≳5 Alfvén times) collimated magnetic jets with a ∼10:1 aspect ratio and long-lived (∼100 μs, ≳40 Alfvén times) flow-stabilized, collimated, magnetic jets with a ∼30:1 aspect ratio.

  7. Formation and sustainment of a very low aspect ratio tokamak using coaxial helicity injection (the Helicity Injected [HIT] experiment). Annual progress report No. 5, December 1, 1993--December 31, 1994

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Nelson, B.A.

    1995-01-01

    This is the fifth Progress Report on the Helicity Injected Tokamak (HIT) at the University of Washington, Seattle, DOE Grant DE-FE06-90ER54095. This report covers the period of December 1, 1993 through December 31

  8. Exxon Nuclear WREM-based NJP-BWR ECCS evaluation model and example application to the Oyster Creek Plant

    International Nuclear Information System (INIS)

    Krysinski, T.L.; Bjornard, T.A.; Steves, L.H.

    1975-01-01

    A proposed integrated ECCS model for non-jet pump boiling water reactors is presented, using the RELAP4-EM/BLOWDOWN and RELAP4-EM/SMALL BREAK portions of the Exxon Nuclear WREM-based Generic PWR Evaluation Model coupled with the ENC NJP-BWR Fuel Heatup Model. The results of the application of the proposed model to Oyster Creek are summarized. The results of the break size sensitivity study using the proposed model for the Oyster Creek Plant are presented. The application of the above results yielded the MAPLHGR curves. Included are a description of the proposed non-jet pump boiling water reaction evaluation model, justification of its conformance with TOCFR50, Appendix K, the adopted Oyster Creek plant model, and results of the analysis and sensitivity studies. (auth)

  9. Study of Impact Damage in PVA-ECC Beam under Low-Velocity Impact Loading Using Piezoceramic Transducers and PVDF Thin-Film Transducers.

    Science.gov (United States)

    Qi, Baoxin; Kong, Qingzhao; Qian, Hui; Patil, Devendra; Lim, Ing; Li, Mo; Liu, Dong; Song, Gangbing

    2018-02-24

    Compared to conventional concrete, polyvinyl alcohol fiber reinforced engineering cementitious composite (PVA-ECC) offers high-strength, ductility, formability, and excellent fatigue resistance. However, impact-induced structural damage is a major concern and has not been previously characterized in PVA-ECC structures. We investigate the damage of PVA-ECC beams under low-velocity impact loading. A series of ball-drop impact tests were performed at different drop weights and heights to simulate various impact energies. The impact results of PVA-ECC beams were compared with mortar beams. A combination of polyvinylidene fluoride (PVDF) thin-film sensors and piezoceramic-based smart aggregate were used for impact monitoring, which included impact initiation and crack evolution. Short-time Fourier transform (STFT) of the signal received by PVDF thin-film sensors was performed to identify impact events, while active-sensing approach was utilized to detect impact-induced crack evolution by the attenuation of a propagated guided wave. Wavelet packet-based energy analysis was performed to quantify failure development under repeated impact tests.

  10. Model experiment on change of seismic properties of a fracture caused by injecting/draining water; Chusui/haisui ni yoru kison kiretsu no dansei denpa tokusei no henka ni kansuru model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, T; Koizumi, T; Sassa, K [Kyoto University, Kyoto (Japan). Faculty of Engineering

    1997-05-27

    Effect of water injection/draining on elastic waves penetrating through cracks is examined by measuring elastic waves before, during, and after the injection/draining of water into/from cracks in presence in granite. Two blocks of rock, with their crack-containing surfaces in contact with each other, are placed in a vessel, and water injection/draining is done through a hole on a vessel bottom side so that water will penetrate into the cracks. When the blocks are dry, there is almost no contact between the cracks, and so no crack penetrating waves are observed. Crack penetrating waves are produced when water is injected, and the position of the receiver sensing the penetrating waves changes as the water level rises. When the water level is lowered from the high water level, the waveform changes again as the level changes. The change in waveform is not so remarkable, however, as that observed during water injection thanks to the water residual in the cracks. It is now inferred that crack investigation is more effective when it is carried out with water being injected into dry cracks. The difference produced between the dry state and wet state when water is injected into dry cracks is used to detect the presence of cracks in this experiment, and this may be applied also to the investigation of cracks in the shallow part of the ground. 4 refs., 11 figs.

  11. Efficient Spin Injection into Semiconductor

    International Nuclear Information System (INIS)

    Nahid, M.A.I.

    2010-06-01

    Spintronic research has made tremendous progress nowadays for making future devices obtain extra advantages of low power, and faster and higher scalability compared to present electronic devices. A spintronic device is based on the transport of an electron's spin instead of charge. Efficient spin injection is one of the very important requirements for future spintronic devices. However, the effective spin injection is an exceedingly difficult task. In this paper, the importance of spin injection, basics of spin current and the essential requirements of spin injection are illustrated. The experimental technique of electrical spin injection into semiconductor is also discussed based on the experimental experience. The electrical spin injection can easily be implemented for spin injection into any semiconductor. (author)

  12. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  13. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  14. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  15. Transient computational fluid dynamics analysis of emergency core cooling injection at natural circulation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Scheuerer, Martina, E-mail: Martina.Scheuerer@grs.de [Gesellschaft fuer Anlagen- und Reaktorsicherheit, Forschungsinstitute, 85748 Garching (Germany); Weis, Johannes, E-mail: Johannes.Weis@grs.de [Gesellschaft fuer Anlagen- und Reaktorsicherheit, Forschungsinstitute, 85748 Garching (Germany)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Pressurized thermal shocks are important phenomena for plant life extension and aging. Black-Right-Pointing-Pointer The thermal-hydraulics of PTS have been studied experimentally and numerically. Black-Right-Pointing-Pointer In the Large Scale Test Facility a loss of coolant accident was investigated. Black-Right-Pointing-Pointer CFD software is validated to simulate the buoyancy driven flow after ECC injection. - Abstract: Within the framework of the European Nuclear Reactor Integrated Simulation Project (NURISP), computational fluid dynamics (CFD) software is validated for the simulation of the thermo-hydraulics of pressurized thermal shocks. A proposed validation experiment is the test series performed within the OECD ROSA V project in the Large Scale Test Facility (LSTF). The LSTF is a 1:48 volume-scaled model of a four-loop Westinghouse pressurized water reactor (PWR). ROSA V Test 1-1 investigates temperature stratification under natural circulation conditions. This paper describes calculations which were performed with the ANSYS CFD software for emergency core cooling injection into one loop at single-phase flow conditions. Following the OECD/NEA CFD Best Practice Guidelines (Mahaffy, 2007) the influence of grid resolution, discretisation schemes, and turbulence models (shear stress transport and Reynolds stress model) on the mixing in the cold leg were investigated. A half-model was used for these simulations. The transient calculations were started from a steady-state solution at natural circulation conditions. The final calculations were obtained in a complete model of the downcomer. The results are in good agreement with data.

  16. Transient computational fluid dynamics analysis of emergency core cooling injection at natural circulation conditions

    International Nuclear Information System (INIS)

    Scheuerer, Martina; Weis, Johannes

    2012-01-01

    Highlights: ► Pressurized thermal shocks are important phenomena for plant life extension and aging. ► The thermal-hydraulics of PTS have been studied experimentally and numerically. ► In the Large Scale Test Facility a loss of coolant accident was investigated. ► CFD software is validated to simulate the buoyancy driven flow after ECC injection. - Abstract: Within the framework of the European Nuclear Reactor Integrated Simulation Project (NURISP), computational fluid dynamics (CFD) software is validated for the simulation of the thermo-hydraulics of pressurized thermal shocks. A proposed validation experiment is the test series performed within the OECD ROSA V project in the Large Scale Test Facility (LSTF). The LSTF is a 1:48 volume-scaled model of a four-loop Westinghouse pressurized water reactor (PWR). ROSA V Test 1-1 investigates temperature stratification under natural circulation conditions. This paper describes calculations which were performed with the ANSYS CFD software for emergency core cooling injection into one loop at single-phase flow conditions. Following the OECD/NEA CFD Best Practice Guidelines (Mahaffy, 2007) the influence of grid resolution, discretisation schemes, and turbulence models (shear stress transport and Reynolds stress model) on the mixing in the cold leg were investigated. A half-model was used for these simulations. The transient calculations were started from a steady-state solution at natural circulation conditions. The final calculations were obtained in a complete model of the downcomer. The results are in good agreement with data.

  17. H- charge exchange injection systems

    International Nuclear Information System (INIS)

    Ankenbrandt, C.; Curtis, C.; Hojvat, C.; Johnson, R.P.; Owen, C.; Schmidt, C.; Teng, L.; Webber, R.C.

    1980-01-01

    The techniques and components required for injection of protons into cyclic accelerators by means of H - charge exchange processes are reviewed, with emphasis on the experience at Fermilab. The advantages of the technique are described. The design and performance of the system of injection of H - ions into the Fermilab Booster are detailed. (Auth.)

  18. Experiences of liver health related uncertainty and self-reported stress among people who inject drugs living with hepatitis C virus: a qualitative study.

    Science.gov (United States)

    Goutzamanis, Stelliana; Doyle, Joseph S; Thompson, Alexander; Dietze, Paul; Hellard, Margaret; Higgs, Peter

    2018-04-02

    People who inject drugs (PWID) are most at risk of hepatitis C virus infection in Australia. The introduction of transient elastography (TE) (measuring hepatitis fibrosis) and direct acting antiviral medications will likely alter the experience of living with hepatitis C. We aimed to explore positive and negative influences on wellbeing and stress among PWID with hepatitis C. The Treatment and Prevention (TAP) study examines the feasibility of treating hepatitis C mono-infected PWID in community settings. Semi-structured interviews were conducted with 16 purposively recruited TAP participants. Participants were aware of their hepatitis C seropositive status and had received fibrosis assessment (measured by TE) prior to interview. Questions were open-ended, focusing on the impact of health status on wellbeing and self-reported stress. Interviews were voice recorded, transcribed verbatim and thematically analysed, guided by Mishel's (1988) theory of Uncertainty in Illness. In line with Mishel's theory of Uncertainty in Illness all participants reported hepatitis C-related uncertainty, particularly mis-information or a lack of knowledge surrounding liver health and the meaning of TE results. Those with greater fibrosis experienced an extra layer of prognostic uncertainty. Experiences of uncertainty were a key motivation to seek treatment, which was seen as a way to regain some stability in life. Treatment completion alleviated hepatitis C-related stress, and promoted feelings of empowerment and confidence in addressing other life challenges. TE scores seemingly provide some certainty. However, when paired with limited knowledge, particularly among people with severe fibrosis, TE may be a source of uncertainty and increased personal stress. This suggests the need for simple education programs and resources on liver health to minimise stress.

  19. Assessment of wall friction model in multi-dimensional component of MARS with air–water cross flow experiment

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jin-Hwa [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Choi, Chi-Jin [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Cho, Hyoung-Kyu, E-mail: chohk@snu.ac.kr [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Euh, Dong-Jin [Korea Atomic Energy Research Institute, 989-111, Daedeok-daero, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Park, Goon-Cherl [Nuclear Thermal-Hydraulic Engineering Laboratory, Seoul National University, Gwanak 599, Gwanak-ro, Gwanak-gu, Seoul 151-742 (Korea, Republic of)

    2017-02-15

    Recently, high precision and high accuracy analysis on multi-dimensional thermal hydraulic phenomena in a nuclear power plant has been considered as state-of-the-art issues. System analysis code, MARS, also adopted a multi-dimensional module to simulate them more accurately. Even though it was applied to represent the multi-dimensional phenomena, but implemented models and correlations in that are one-dimensional empirical ones based on one-dimensional pipe experimental results. Prior to the application of the multi-dimensional simulation tools, however, the constitutive models for a two-phase flow need to be carefully validated, such as the wall friction model. Especially, in a Direct Vessel Injection (DVI) system, the injected emergency core coolant (ECC) on the upper part of the downcomer interacts with the lateral steam flow during the reflood phase in the Large-Break Loss-Of-Coolant-Accident (LBLOCA). The interaction between the falling film and lateral steam flow induces a multi-dimensional two-phase flow. The prediction of ECC flow behavior plays a key role in determining the amount of coolant that can be used as core cooling. Therefore, the wall friction model which is implemented to simulate the multi-dimensional phenomena should be assessed by multidimensional experimental results. In this paper, the air–water cross film flow experiments simulating the multi-dimensional phenomenon in upper part of downcomer as a conceptual problem will be introduced. The two-dimensional local liquid film velocity and thickness data were used as benchmark data for code assessment. And then the previous wall friction model of the MARS-MultiD in the annular flow regime was modified. As a result, the modified MARS-MultiD produced improved calculation result than previous one.

  20. Coolant Mixing in a Pressurized Water Reactor: Deboration Transients, Steam-Line Breaks, and Emergency Core Cooling Injection

    International Nuclear Information System (INIS)

    Prasser, Horst-Michael; Grunwald, Gerhard; Hoehne, Thomas; Kliem, Soeren; Rohde, Ulrich; Weiss, Frank-Peter

    2003-01-01

    emergency core cooling (ECC) water entering the RPV through the ECC injection into the cold leg. The experimental results show an incomplete mixing with typical concentration and temperature distributions at the core inlet, which strongly depend on the boundary conditions. Computational fluid dynamics calculations were found to be in good agreement with the experiments

  1. Planning of in-situ experiment for understanding of gas migration behaviour in sedimentary rock. (1) Setting of gas injection procedure

    International Nuclear Information System (INIS)

    Tanai, Kenji; Fujita, Tomoo; Noda, Masaru; Yamamoto, Shuichi; Shimura, Tomoyuki; Sato, Shin

    2013-01-01

    Japan Atomic Energy Agency has been planning in-situ gas migration test in Horonobe URL, Hokkaido. This paper discusses the optimum gas injection procedure for the test to understand gas migration behaviour in surrounded rock. The stepwise constant gas injection was selected, taking into account domestic and overseas gas related research results. Hydro-mechanical-gas coupling analysis which is able to consider the dissolved methane in Horonobe groundwater was applied to evaluate the gas behaviour. The results have indicated no significant mechanical damages to the rock and have supported the appropriateness of selected gas injection procedure for the test. (author)

  2. Summary of CCTF test results - assessment of current safety evaluation analysis on reflood behaviour during a LOCA in a PWR with cold-leg-injection-type ECCS

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Murao, Yoshio; Sugimoto, Jun; Akimoto, Hajime; Okubo, Tsutomu; Hojo, Tsuneyuki

    1988-01-01

    The conservatism of the current safety analysis was assessed by comparing the predicted results with cylindrical core test facility (CCTF) test results performed at JAERI. The WREM code was selected for the assessment. The overall conservatism of the WREM code on the peak clad temperature prediction was confirmed against CCTF EM test which simulated the typical initial and boundary conditions in the safety evaluation analysis. The WREM code predicted the reasonable core boundary conditions and the conservatism of the code came mainly from the core calculation. The conservatism of the WREM code against CCTF data could be attributed to the following three points: (i) no horizontal mixing assumption between subchannels at each elevation, (ii) no modeling on heat transfer enhancement caused by the radial core power profile, (iii) usage of conservative heat transfer correlations in the code. (orig./HP)

  3. Risk-Informed Margin Management (RIMM) Industry Applications IA1 - Integrated Cladding ECCS/LOCA Performance Analysis - Problem Statement

    Energy Technology Data Exchange (ETDEWEB)

    Szilard, Ronaldo Henriques [Idaho National Lab. (INL), Idaho Falls, ID (United States); Youngblood, Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Frepoli, Cesare [Idaho National Lab. (INL), Idaho Falls, ID (United States); Yurko, Joseph P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swindlehurst, Gregg [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bayless, Paul D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Smith, Curtis L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-04-01

    The U. S. NRC is currently proposing rulemaking designated as “10 CFR 50.46c” to revise the LOCA/ECCS acceptance criteria to include the effects of higher burnup on cladding performance as well as to address some other issues. The NRC is also currently resolving the public comments with the final rule expected to be issued in the summer of 2016. The impact of the final 50.46c rule on the industry will involve updating of fuel vendor LOCA evaluation models, NRC review and approval, and licensee submittal of new LOCA evaluations or reanalyses and associated technical specification revisions for NRC review and approval. The rule implementation process, both industry and NRC activities, is expected to take 5-10 years following the rule effective date. The need to use advanced cladding designs is expected. A loss of operational margin will result due to the more restrictive cladding embrittlement criteria. Initial and future compliance with the rule may significantly increase vendor workload and licensee cost as a spectrum of fuel rod initial burnup states may need to be analyzed to demonstrate compliance. Consequently there will be an increased focus on licensee decision making related to LOCA analysis to minimize cost and impact, and to manage margin.

  4. A photographic portrait of Father Benignus Wanat, discalced Carmelite, with Christ’s head Ecce Homo in the background

    Directory of Open Access Journals (Sweden)

    Inga Platowska-Sapetowa

    2016-12-01

    Full Text Available This photographic memory of the late Father Benignus Józef Wanat OCD is based upon a high quality photo, anonymously posted and found accidentally on Facebook on 11 April 2013 after his funeral. Investigations established that the photographer, Jacek Praśkiewicz, is a photographer from Kielce. Additionally, the work includes a descriptive analysis of various aspects of several works of art: a psycho-physical description of the character portrayed its settings and lighting, a description of the ceremonial costume used and its symbolic elements. It has been established that the photo was taken at a celebration of an anniversary held on 12 December 2008. What is crucial to emphasise is this: the relationship of the portrayed person (Fr Benignus Józef Wanat OCD with the portrait’s background, which uses a fragmented image of Christ Ecce Homo, which is of unknown provenance. This latter aspect included a description of the work which is very important, because it shows the supporting facts taken from the biography of Father Benignus, corroborated by the statements of witnesses, of his imitative attitude to Christ, in relation to God-Man suffering in humble silence and bringing aid to his fellow human even to the extent of the sacrifice of his life. [Translatio by Fr E. Wanat SDS

  5. Study on safety analysis of VVER-1200/V491 in scenario of Loss of Coolant Accidents along with partly failure of ECCS using RELAP5 code

    International Nuclear Information System (INIS)

    Hoang Minh Giang; Ha Thi Anh Dao; Hoang Tan Hung; Bui Thi Hoa; Nguyen Thi Tu Oanh; Dinh Anh Tuan; Pham Tuan Nam

    2017-01-01

    The advanced VVER-1200/V491 reactor designed with passive safety systems to deal with design extension conditions is primarily selected as priority candidate for Ninh Thuan 1 nuclear power plant project. So that, in order to enhance competence of nuclear safety and toward participation on review Safety Analysis Report (SAR) of Ninh Thuan nuclear Power project the study on safety analysis of VVER-1200/V491 in scenario of Loss of Coolant Accidents along with partly failure of ECCS is implemented. As requirement of the study, the input deck file of VVER-1200/V491 for RELAP5 and analysis report for some special case of LOCAs along with partly failure of ECCS are issued. (author)

  6. Industry Application ECCS / LOCA Integrated Cladding/Emergency Core Cooling System Performance: Demonstration of LOTUS-Baseline Coupled Analysis of the South Texas Plant Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Szilard, Ronaldo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Epiney, Aaron [Idaho National Lab. (INL), Idaho Falls, ID (United States); Parisi, Carlo [Idaho National Lab. (INL), Idaho Falls, ID (United States); Vaghetto, Rodolfo [Texas A & M Univ., College Station, TX (United States); Vanni, Alessandro [Texas A & M Univ., College Station, TX (United States); Neptune, Kaleb [Texas A & M Univ., College Station, TX (United States)

    2017-06-01

    Under the auspices of the DOE LWRS Program RISMC Industry Application ECCS/LOCA, INL has engaged staff from both South Texas Project (STP) and the Texas A&M University (TAMU) to produce a generic pressurized water reactor (PWR) model including reactor core, clad/fuel design and systems thermal hydraulics based on the South Texas Project (STP) nuclear power plant, a 4-Loop Westinghouse PWR. A RISMC toolkit, named LOCA Toolkit for the U.S. (LOTUS), has been developed for use in this generic PWR plant model to assess safety margins for the proposed NRC 10 CFR 50.46c rule, Emergency Core Cooling System (ECCS) performance during LOCA. This demonstration includes coupled analysis of core design, fuel design, thermalhydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results. Within this context, a multi-physics best estimate plus uncertainty (MPBEPU) methodology framework is proposed.

  7. Verification of LOCA/ECCS analysis codes ALARM-B2 and THYDE-B1 by comparison with RELAP4/MOD6/U4/J3

    International Nuclear Information System (INIS)

    Shimizu, Takashi

    1982-08-01

    For a verification study of ALARM-B2 code and THYDE-B1 code which are the component of the JAERI code system for evaluation of BWR ECCS performance, calculations for typical small and large break LOCA in BWR were done, and compared with those by RELAP4/MOD6/U4/J3 code. This report describes the influences of differences between the analytical models incorporated in the individual code and the problems identified by this verification study. (author)

  8. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  9. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  10. Fibre Length Reduction in Natural Fibre-Reinforced Polymers during Compounding and Injection Moulding—Experiments Versus Numerical Prediction of Fibre Breakage

    Directory of Open Access Journals (Sweden)

    Katharina Albrecht

    2018-03-01

    Full Text Available To establish injection-moulded, natural fibre-reinforced polymers in the automotive industry, numerical simulations are important. To include the breakage behaviour of natural fibres in simulations, a profound understanding is necessary. In this study, the length and width reduction of flax and sisal fibre bundles were analysed experimentally during compounding and injection moulding. Further an optical analysis of the fibre breakage behaviour was performed via scanning electron microscopy and during fibre tensile testing with an ultra-high-speed camera. The fibre breakage of flax and sisal during injection moulding was modelled using a micromechanical model. The experimental and simulative results consistently show that during injection moulding the fibre length is not reduced further; the fibre length was already significantly reduced during compounding. For the mechanical properties of a fibre-reinforced composite it is important to overachieve the critical fibre length in the injection moulded component. The micromechanical model could be used to predict the necessary fibre length in the granules.

  11. Water volume available for ECCS sump recirculation mode following a LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Riekert, T. [TUV NORD SysTec (Germany); Rebohm, H. [TUV NORD EnSys Hannover (Germany); Huber, J. [TUV SUD IS (Germany); Brandes, F. [TUV SUD ET (Germany)

    2006-07-01

    In this paper we describe the reviews performed in Germany on the water level in the containment sump after a LOCA and the derived actions. Our view on the issue is from the perspective of the independent safety experts - i.e. TUV SUD Industrie Service (TUV SUD IS), TUV SUD Energietechnik GmbH Baden-Wuerttemberg (TUV SUD ET), TUV NORD EnSys Hannover and TUV NORD SysTec -, which reviewed the analyses of the utilities on behalf of the responsible supervising authorities. Between these expert organizations information were exchanged via the steering committee on nuclear technology of the association of the TUVs (VdTUV). In our paper we describe the analyses on the two safety issues relevant in the connection with the water level in the containment sump: the necessary minimum coverage of suction pipes to avoid inadmissible entrainment of air and the water retention inside the containment after a LOCA. Our description concentrates on PWRs because of the more complex conditions in comparison to BWRs. In conclusion it can be stated that due to the thorough evaluation of operating experience, optimization measures could be derived. In addition, the analyses served the purpose of know-how maintenance. (authors)

  12. Water volume available for ECCS sump recirculation mode following a LOCA

    International Nuclear Information System (INIS)

    Riekert, T.; Rebohm, H.; Huber, J.; Brandes, F.

    2006-01-01

    In this paper we describe the reviews performed in Germany on the water level in the containment sump after a LOCA and the derived actions. Our view on the issue is from the perspective of the independent safety experts - i.e. TUV SUD Industrie Service (TUV SUD IS), TUV SUD Energietechnik GmbH Baden-Wuerttemberg (TUV SUD ET), TUV NORD EnSys Hannover and TUV NORD SysTec -, which reviewed the analyses of the utilities on behalf of the responsible supervising authorities. Between these expert organizations information were exchanged via the steering committee on nuclear technology of the association of the TUVs (VdTUV). In our paper we describe the analyses on the two safety issues relevant in the connection with the water level in the containment sump: the necessary minimum coverage of suction pipes to avoid inadmissible entrainment of air and the water retention inside the containment after a LOCA. Our description concentrates on PWRs because of the more complex conditions in comparison to BWRs. In conclusion it can be stated that due to the thorough evaluation of operating experience, optimization measures could be derived. In addition, the analyses served the purpose of know-how maintenance. (authors)

  13. Experiences of PEMEX in CO{sub 2} re-injection; Experiencias de Pemex en reinyeccion de CO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Bujanos, Jose Luis [PEMEX (Mexico)

    2008-07-15

    Mexico enters the processes of secondary oil recovery the years 50s, by means of water injection. The CO{sub 2} injection is one of the techniques that better results produce in the oil recovery. In this presentation the strategic goals that have been determined within PEMEX Exploracion y Produccion (PEP) are mentioned, and which are the projects of CO{sub 2} injection for oil recovery already existing in Mexico. [Spanish] Mexico entra a los procesos de recuperacion secundaria de petroleo en los anos 50s, mediante inyeccion de agua. La inyeccion de CO{sub 2} es una de las tecnicas que mejores resultados produce en la recuperacion de petroleo. En esta presentacion se mencionan las metas estrategicas que se han fijado dentro de Pemex Exploracion y Produccion (PEP) y cuales son los proyectos de inyeccion de CO{sub 2} para recuperacion de petroleo, existentes actualmente en Mexico.

  14. "Until people start dying in droves, no actions will be taken": perception and experience of HIV-preventive measures among people who inject drugs in northwestern Russia.

    Science.gov (United States)

    Meylakhs, Peter; Aasland, Aadne; Grønningsæter, Arne

    2017-06-05

    The HIV epidemic among people who inject drugs (PWID) in Russia continues to spread. This exploratory study examines how HIV-prevention measures are perceived and experienced by PWID in the northwestern region of Russia. Purposive sampling was used to obtain a variety of cases that could reflect possible differences in perception and experience of HIV-prevention efforts. We conducted 22 semi-structured interviews with PWID residing in the Arkhangelsk and St. Petersburg regions. The main sources of prevention information on HIV for PWID were media campaigns directed to the general population. These campaigns were effective with regard to communicating general knowledge on HIV but were ineffective in terms of risk behavior change. The subjects generally had trust in medical professionals and their advice but did not follow prevention recommendations. Most informants had no or very little prior contact with harm reduction services. On the level of attitudes towards HIV prevention efforts, we discovered three types of fatalism among PWID: "personal fatalism" - uselessness of HIV prevention efforts, if one uses drugs; "prevention-related fatalism" - prevention programs are low effective, because people do not pay attention to them before they get infected; "state-related fatalism" - the lack of belief that the state is concerned with HIV prevention issues. Despite this fatalism the participants opined that NGOs would do a better job than the state as they are "really working" with risk groups. As HIV prevention campaigns targeted at the general population and prevention advice received from medical professionals are not sufficiently effective for PWID in terms of risk behavior change, prevention programs, such as community-based and peer-based interventions specifically tailored to the needs of PWID are needed, which can be achieved by a large expansion of harm reduction services in the region. Personal communication should be a crucial element in such interventions in

  15. A methodology for the estimation of release of fission products during LOCA with loss of ECCS

    International Nuclear Information System (INIS)

    Lele, H.G.; Majumdar, P.; Mukhopadhyay, D.; Gupta, S.K.; Venkat Raj, V.

    2002-01-01

    A Loss of Coolant Accident (LOCA) in a nuclear reactor along with the failure of the Emergency Core Cooling System can cause sustained voiding of the core. In such a situation the core experiences very low flow which leads to poor heat removal from the reactor core. The heat to be removed from the core includes stored heat, heat generated due to metal water reaction at high temperatures, decay heat etc. The poor heat removal leads to heating of the fuel pins to high temperatures. The heating of fuel pins is further enhanced due to metal-water reaction at high temperatures. These high temperatures of the fuel pins can lead to fission product release, which is transported into the Primary Heat Transport (PHT) system and can enter the containment through the break. Analysis is involved due to the complexity of the system and the phenomena to be simulated. In this paper a multistage analysis methodology is presented that involves the development and application of a number of computer programs to model the various phenomena involved. The computer code PHTACT computes the activity release from the fuel as a function of fuel temperatures and cladding oxidation, its distribution into the PHT system and release into the containment. Computation of thermal hydraulic parameters during LOCA is done using the thermal hydraulic analysis code RELAP5. The detailed simulation of fuel pin temperatures is done using computer code HT/MOD4. The convective boundary conditions required for the code are obtained from RELAP5. Creep deformation is considered in the computation of dimensional changes of the coolant channel and estimation of flow blockage due to clad ballooning. The progression of various reaction layers due to high temperature reaction between fuel and clad and clad and steam is also computed, which affects the structural strength of the clad. Different approaches are possible and analysis can be carried out in different phases depending upon the complexities to be

  16. Data report for ROSA-IV LSTF 10% hot leg break experiment Run SB-HL-02

    International Nuclear Information System (INIS)

    Kukita, Yutaka; Hirata, Kazuo; Gotou, Hiroki

    1990-03-01

    Experimental data for the 10% hot leg break test, Run SB-HL-02, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on June 30, 1987, are presented. This test assumed total failure of both high pressure injection (HPI) and auxiliary feedwater (AFW) systems. The test results were characterized by asymmetric loop responses, flashing in the cold legs and upper downcomer, as well as condensation depressurization in the cold legs following injection of emergency core coolant (ECC) from accumulators. (author)

  17. Numerical investigation on lithium transport in the edge plasma of EAST real-time- Li-injection experiments in the frame of BOUT++

    Directory of Open Access Journals (Sweden)

    N.M. Li

    2017-08-01

    Full Text Available To study the transport of Li species in the plasma with real-time Li aerosol injection on EAST, a model has been developed by reducing Braginskii's equations, and implemented in the frame of BOUT++. The simulation results show that Li atoms propagate inwards since the Li injection, and their penetration depth depends on both the local plasma conditions along their path and initial injection velocity. It is also found that Li ions accumulate rapidly in the edge, and only a small fraction of Li species can transport cross the separatrix into the core. In the poloidal direction, Li ions drift swiftly downwards along the field lines, and transport much faster at the high field side than at the low field side. The interaction between background plasma and Li species plays a critical role in determining the edge plasma profile. It is found that real-time Li injection raises the plasma density in the pedestal region and reduces the plasma temperature, just as has been observed experimentally.

  18. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings - Part II: Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Fuerst, Axel; Santos, Ilmar

    2007-01-01

    This is Part II of a two-part series of papers describing the effects of high-pressure injection pockets on the operating conditions of tilting-pad thrust bearings. The paper has two main objectives. One is an experimental investigation of the influence of an oil injection pocket on the pressure...... and without oil injection) on the pressure distribution and oil film thickness. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approx. 100 cm^2 surface area. Two pads are measured in a laboratory test rig at loads of approx. 1.5 MPa...... and approx. 4.0 MPa and velocities of up to 33 m/s. One pad has a plain surface. The other pad has a conical injection pocket at the pivot point and a leading-edge taper. The measurements are compared to theoretical values obtained using a three-dimensional thermoelastohydrodynamic (TEHD) numerical model...

  19. Collagenase injections for the treatment of single cords in cases of Dupuytren’s contracture – a prospective intervention study of long-term experience with Xiapex

    Directory of Open Access Journals (Sweden)

    Fischer, Lisa Maria

    2017-04-01

    Full Text Available Introduction: The gold standard in the treatment of Dupuytren’s contracture is surgical therapy. Alternatives are percutaneous needle fasciotomy and radiation in exceptional cases. Injection treatments with Xiapex (Pfizer are a new therapy option. This collagenase, extracted from clostridium histolyticum, is used to break down the affected tissue cords. The objective of this study is to examine the effect and long-term success of treatment with Xiapex.Methods: In this study, Xiapex treatment was conducted on a sample group of 19 patients with Dupuytren’s contracture. The injection was placed either on the cord at the level of the metacarpophalangeal (MCP joint (n=17 or of the proximal interphalangeal (PIP joint (n=7. Break-up of the cord occurred 24 hours after the injection. The neutral zero method was used to assess the extent of movement. The Michigan Hand Outcomes Questionnaire (MHQ was selected for evaluation of the general hand function in 16 patients. The WHO-5 and the EQ-5D VAS Score were used as a measure of the patients’ satisfaction and their state of health. All values were collected both pre-injection as well as 1 year post-injection.Results: Out of 19 patients in our sample group, 16 patients (≈84% benefitted in terms of improvement in mobility. Overall, the range of movement increased by Ø 26° in the affected finger. A separate assessment demonstrated that:The range of movement increased by 77% in the MCP joint. The extent of movement pre-injection was Ø (0-28-78 and post-injection it was Ø (0-9-81 with an improvement of Ø 22°. In the PIP joint, only slight improvement was observed (Ø pre (0-27-93; post (0-24-95.The MHQ increased from Ø 76% (R: 32–97% to 81% (R: 39–100%.The painfulness decreased from Ø 19% (R: 0–55% to Ø11% (R: 0–55%, corresponding to Ø 43%. Satisfaction increased in 72% of patients by Ø 21%.According to WHO-5, patient satisfaction pre-injection was Ø 20 (R: 11–25, and 1 year after

  20. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  1. ECCS control circuit

    International Nuclear Information System (INIS)

    Sato, Takashi.

    1986-01-01

    Purpose: To afford a sufficient margin to pressure vibrations upon starting of an automatic depressurization system by dispersing pressure vibration in suppression water due to the opening action of an automatic releaf valve in the automatic depressurization system thereby reducing the dynamic load exerted to the surface of the suppression walls. Constitution: Upon occurrence of loss of coolant accidents, an automatic releaf valve for automatic depressurization is opened to deliver the steams in the pressure vessel into the suppression pool. Since a plurality of automatic releaf valves have usually been disposed, if they are opened simultaneously, excess dynamic loads are exerted due to the pressure vibrations to the wall surface of the suppression pool. In this invention, a control circuit is disposed such that the opening timing for each of the automatic releaf valves is deviated upon occurrence of a driving signal for the automatic depressurization system to thereby disperse the pressure vibrations in the suppression water. (Kamimura, M.)

  2. Reduction of plasma density in the Helicity Injected Torus with Steady Inductance experiment by using a helicon pre-ionization source

    International Nuclear Information System (INIS)

    Hossack, Aaron C.; Jarboe, Thomas R.; Victor, Brian S.; Firman, Taylor; Prager, James R.; Ziemba, Timothy; Wrobel, Jonathan S.

    2013-01-01

    A helicon based pre-ionization source has been developed and installed on the Helicity Injected Torus with Steady Inductance (HIT-SI) spheromak. The source initiates plasma breakdown by injecting impurity-free, unmagnetized plasma into the HIT-SI confinement volume. Typical helium spheromaks have electron density reduced from (2–3) × 10 19 m −3 to 1 × 10 19 m −3 . Deuterium spheromak formation is possible with density as low as 2 × 10 18 m −3 . The source also enables HIT-SI to be operated with only one helicity injector at injector frequencies above 14.5 kHz. A theory explaining the physical mechanism driving the reduction of breakdown density is presented

  3. Reduction of plasma density in the Helicity Injected Torus with Steady Inductance experiment by using a helicon pre-ionization source

    Energy Technology Data Exchange (ETDEWEB)

    Hossack, Aaron C.; Jarboe, Thomas R.; Victor, Brian S. [Department of Aeronautics and Astronautics, University of Washington, Seattle, Washington 98195 (United States); Firman, Taylor; Prager, James R.; Ziemba, Timothy [Eagle Harbor Technologies, Inc., 119 W. Denny Way, Suite 210, Seattle, Washington 98119 (United States); Wrobel, Jonathan S. [979B West Moorhead Circle, Boulder, Colorado 80305 (United States)

    2013-10-15

    A helicon based pre-ionization source has been developed and installed on the Helicity Injected Torus with Steady Inductance (HIT-SI) spheromak. The source initiates plasma breakdown by injecting impurity-free, unmagnetized plasma into the HIT-SI confinement volume. Typical helium spheromaks have electron density reduced from (2–3) × 10{sup 19} m{sup −3} to 1 × 10{sup 19} m{sup −3}. Deuterium spheromak formation is possible with density as low as 2 × 10{sup 18} m{sup −3}. The source also enables HIT-SI to be operated with only one helicity injector at injector frequencies above 14.5 kHz. A theory explaining the physical mechanism driving the reduction of breakdown density is presented.

  4. The Influence of Injection Pockets on the Performance of Tilting-Pad Thrust Bearings: Part II – Comparison Between Theory and Experiment

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar

    2006-01-01

    This is Part II of a two-part series of papers describing the effects of high pressure injection pockets on the operating conditions of tilting-pad thrust bearings. Measurements of the distribution of pressure and oil film thickness are presented for tilting-pad thrust bearing pads of approximately...... 100 cm2 surface area. Two pads are measured in a laboratory test-rig at loads of approximately 0.5, 1.5 and 4.0 MPa and velocities of up to 33 m/s. One pad has a plain surface. The other pad has a conical injection pocket at the pivot point and a leading edge taper. The measurements are compared...... to theoretical values obtained using a three dimensional thermo-elasto-hydrodynamic (TEHD) numerical model. At low and intermediate loads the theoretical pressure distribution corresponds well to the measured values for both pads although the influence of the pocket is slightly underestimated. At high loads...

  5. Single center experience with endoscopic subureteral dextranomer/hyaluronic acid injection as first line treatment in 1,551 children with intermediate and high grade vesicoureteral reflux.

    Science.gov (United States)

    Puri, Prem; Kutasy, Balazs; Colhoun, Eric; Hunziker, Manuela

    2012-10-01

    In recent years the endoscopic injection of dextranomer/hyaluronic acid has become an established alternative to long-term antibiotic prophylaxis and the surgical management of vesicoureteral reflux. We determined the safety and effectiveness of the endoscopic injection of dextranomer/hyaluronic acid as first line treatment for high grade vesicoureteral reflux. Between 2001 and 2010, 1,551 children (496 male, 1,055 female, median age 1.6 years) underwent endoscopic correction of intermediate and high grade vesicoureteral reflux using dextranomer/hyaluronic acid soon after the diagnosis of vesicoureteral reflux on initial voiding cystourethrogram. Vesicoureteral reflux was unilateral in 761 children and bilateral in 790. Renal scarring was detected in 369 (26.7%) of the 1,384 patients who underwent dimercapto-succinic acid imaging. Reflux grade in the 2,341 ureters was II in 98 (4.2%), III in 1,340 (57.3%), IV in 818 (34.9%) and V in 85 (3.6%). Followup ultrasound and voiding cystourethrogram were performed 3 months after the outpatient procedure, and renal ultrasound was performed annually thereafter. Patients were followed for 3 months to 10 years (median 5.6 years). Vesicoureteral reflux resolved after the first, second and third endoscopic injection of dextranomer/hyaluronic acid in 2,039 (87.1%), 264 (11.3%) and 38 (1.6%) ureters, respectively. Febrile urinary tract infections developed during followup in 69 (4.6%) patients. None of the patients in the series needed reimplantation of ureters or experienced any significant complications. Our results confirm the safety and efficacy of the endoscopic injection of dextranomer/hyaluronic acid in the eradication of high grade vesicoureteral reflux. We recommend this 15-minute outpatient procedure as the first line of treatment for high grade vesicoureteral reflux. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Injection device-related risk management toward safe administration of medications: experience in a university teaching hospital in The People’s Republic of China

    OpenAIRE

    Zhu, Ling-ling; Li, Wei; Song, Ping; Zhou, Quan

    2014-01-01

    Ling-ling Zhu,1 Wei Li,2 Ping Song,3 Quan Zhou3 1Geriatric VIP Ward, Division of Nursing, 2Division of Medical Administration, 3Department of Pharmacy, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, People's Republic of China Abstract: The use of injection devices to administer intravenous or subcutaneous medications is common practice throughout a variety of health care settings. Studies suggest that one-half of all harmful medication errors origi...

  7. Considerations for Probabilistic Analyses to Assess Potential Changes to Large-Break LOCA Definition for ECCS Requirements

    International Nuclear Information System (INIS)

    Wilkowski, G.; Rudland, D.; Wolterman, R.; Krishnaswamy, P.; Scott, P.; Rahman, S.; Fairbanks, C.

    2002-01-01

    The U.S.NRC has undertaken a study to explore changes to the body of Part 50 of the U.S. Federal Code of Regulations, to incorporate risk-informed attributes. One of the regulations selected for this study is 10 CFR 50.46, A cceptance Criteria for Emergency Core Cooling Systems for Light-Water Nuclear Power Reactors . These changes will potentially enhance safety and reduce unnecessary burden on utilities. Specific attention is being paid to redefining the maximum pipe break size for LB-LOCA by determining the spectrum of pipe diameter (or equivalent opening area) versus failure probabilities. In this regard, it is necessary to ensure that all contributors to probabilistic failures are accounted for when redefining ECCS requirements. This paper describes initial efforts being conducted for the U.S.NRC on redefining the LB-LOCA requirements. Consideration of the major contributors to probabilistic failure, and deterministic aspects for modeling them, are being addressed. At this time three major contributors to probabilistic failures are being considered. These include: (1) Analyses of the failure probability from cracking mechanisms that could involve rupture or large opening areas from either through-wall or surface flaws, whether the pipe system was approved for leak-before-break (LBB) or not. (2) Future degradation mechanisms, such as recent occurrence of PWSCC in PWR piping need to be included. This degradation mechanism was not recognized as being an issue when LBB was approved for many plants or when the initial risk-informed inspection plans were developed. (3) Other indirect causes of loss of pressure-boundary integrity than from cracks in the pipe system also should be included. The failure probability from probabilistic fracture mechanics will not account for these other indirect causes that could result in a large opening in the pressure boundary: i.e., failure of bolts on a steam generator manway, flanges, and valves; outside force damage from the

  8. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  9. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  10. Injection of zinc in plants of ANAV. Impact on fuel and operation experience; Inyeccion de cinc en las plantas de ANAV. Impacto sobre el combustible y experiencia de operacion

    Energy Technology Data Exchange (ETDEWEB)

    Doncell, N.; Gago, J. L.

    2015-07-01

    Zinc injection performed in the three ANAV (Asociacion Nuclear Asco-Vandellos) plants is part of an overall primary water chemistry program, material management and dose reduction program. The application of zinc shown significant benefits in radiation field reduction as well as in mitigation of PWSCC initiation. Although zinc injection also reduces general corrosion rates and consequently reduces corrosion product transport to the fuel, and evaluation of the risks with respect to fuel performance should be done. ANAV and ENUSA, following industry recommendations, have coordinated the task related to the viability of the program in Asco and Vandellos including monitoring, inspections and control parameters. finally, this article includes a comprehensive review of operating experience and an assessment of fuel performance effects. (Author)

  11. Twenty-third water reactor safety information meeting. Volume 3, structural and seismic engineering, primary systems integrity, equipment operability and aging, ECCS strainer blockage research and regulatory issues

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 3, presents topics in Structural & Seismic Engineering, Primary Systems Integrity, Equipment Operability and Aging, and ECCS Strainer Blockage Research & Regulatory Issues. Individual papers have been cataloged separately.

  12. Twenty-third water reactor safety information meeting. Volume 3, structural and seismic engineering, primary systems integrity, equipment operability and aging, ECCS strainer blockage research and regulatory issues

    International Nuclear Information System (INIS)

    Monteleone, S.

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 3, presents topics in Structural ampersand Seismic Engineering, Primary Systems Integrity, Equipment Operability and Aging, and ECCS Strainer Blockage Research ampersand Regulatory Issues. Individual papers have been cataloged separately

  13. ATHLET validation using accident management experiments

    Energy Technology Data Exchange (ETDEWEB)

    Teschendorff, V.; Glaeser, H.; Steinhoff, F. [Gasellschaft fuer Anlagen - und Reaktorsicherheit (GSR) mbH, Garching (Germany)

    1995-09-01

    The computer code ATHLET is being developed as an advanced best-estimate code for the simulation of leaks and transients in PWRs and BWRs including beyond design basis accidents. The code has features that are of special interest for applications to small leaks and transients with accident management, e.g. initialisation by a steady-state calculation, full-range drift-flux model, and dynamic mixture level tracking. The General Control Simulation Module of ATHLET is a flexible tool for the simulation of the balance-of-plant and control systems including the various operator actions in the course of accident sequences with AM measures. The systematic validation of ATHLET is based on a well balanced set of integral and separate effect tests derived from the CSNI proposal emphasising, however, the German combined ECC injection system which was investigated in the UPTF, PKL and LOBI test facilities. PKL-III test B 2.1 simulates a cool-down procedure during an emergency power case with three steam generators isolated. Natural circulation under these conditions was investigated in detail in a pressure range of 4 to 2 MPa. The transient was calculated over 22000 s with complicated boundary conditions including manual control actions. The calculations demonstrations the capability to model the following processes successfully: (1) variation of the natural circulation caused by steam generator isolation, (2) vapour formation in the U-tubes of the isolated steam generators, (3) break-down of circulation in the loop containing the isolated steam generator following controlled cool-down of the secondary side, (4) accumulation of vapour in the pressure vessel dome. One conclusion with respect to the suitability of experiments simulating AM procedures for code validation purposes is that complete documentation of control actions during the experiment must be available. Special attention should be given to the documentation of operator actions in the course of the experiment.

  14. Performance Verification for Safety Injection Tank with Fluidic Device

    International Nuclear Information System (INIS)

    Yune, Seok Jeong; Kim, Da Yong

    2014-01-01

    In LBLOCA, the SITs of a conventional nuclear power plant deliver excessive cooling water to the reactor vessel causing the water to flow into the containment atmosphere. In an effort to make it more efficient, Fluidic Device (FD) is installed inside a SIT of Advanced Power Reactor 1400 (APR 1400). FD, a complete passive controller which doesn't require actuating power, controls injection flow rates which are susceptible to a change in the flow resistance inside a vortex chamber of FD. When SIT Emergency Core Cooling (ECC) water level is above the top of the stand pipe, the water enters the vortex chamber through both the top of the stand pipe and the control ports resulting in injection of the water at a large flow rate. When the water level drops below the top of the stand pipe, the water only enters the vortex chamber through the control ports resulting in vortex formation in the vortex chamber and a relatively small flow injection. Performance verification of SIT shall be carried out because SITs play an integral role to mitigate accidents. In this paper, the performance verification method of SIT with FD is presented. In this paper, the equations for calculation of flow resistance coefficient (K) are induced to evaluate on-site performance of APR 1400 SIT with FD. Then, the equations are applied to the performance verification of SIT with FD and good results are obtained

  15. High frequency injection assisted “active flux” based sensorless vector control of reluctance synchronous motors, with experiments from zero speed

    DEFF Research Database (Denmark)

    Agarliţă, Sorin-Cristian; Boldea, I.; Blaabjerg, Frede

    2011-01-01

    This paper presents a hybrid, motion sensorless control of an Axially Laminated Anisotropic (ALA) Reluctance Synchronous Machine (RSM). The zero and low speed sensorless method is a saliency based High Frequency Signal Injection technique (HFSI) that uses the motor itself as a resolver. The second...... method is based on a state observer incorporating the “active flux” concept used to deliver RSM rotor position and speed information for medium and high speed range. Even if both methods perform successfully in separate speed regions, estimation of the two algorithms is combined as a sensor fusion...... to improve performance at zero and very low speeds. Experimental results validate the proposed control strategies....

  16. High frequency injection assisted “active flux” based sensorless vector control of reluctance synchronous motors, with experiments from zero speed

    DEFF Research Database (Denmark)

    Agarlita, Sorin-Cristian; Boldea, Ion; Blaabjerg, Frede

    2012-01-01

    This paper presents a hybrid, motion sensorless control of an Axially Laminated Anisotropic (ALA) Reluctance Synchronous Machine (RSM). The zero and low speed sensorless method is a saliency based High Frequency Signal Injection technique (HFSI) that uses the motor itself as a resolver. The second...... method is based on a state observer incorporating the “active flux” concept used to deliver RSM rotor position and speed information for medium and high speed range. Even if both methods perform successfully in separate speed regions, estimation of the two algorithms is combined as a sensor fusion...... to improve performance at zero and very low speeds. Experimental results validate the proposed control strategies....

  17. Non-double-couple mechanisms of microearthquakes induced during the 2000 injection experiment at the KTB site, Germany: A result of tensile faulting or anisotropy of a rock?

    Czech Academy of Sciences Publication Activity Database

    Vavryčuk, Václav; Bohnhoff, M.; Jechumtálová, Zuzana; Kolář, Petr; Šílený, Jan

    2008-01-01

    Roč. 456, č. 1-2 (2008), s. 74-93 ISSN 0040-1951 R&D Projects: GA AV ČR KJB300120504; GA AV ČR IAA3012309; GA AV ČR IAA300120502 Grant - others:EC(XE) MTKI-CT-2004-517242 Institutional research plan: CEZ:AV0Z30120515 Keywords : anisotropy * fluid injection * focal mechanism * tensile faulting Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 1.677, year: 2008

  18. Reflooding and boil-off experiments in a VVER-440 like rod bundle and analyses with the CATHARE code

    International Nuclear Information System (INIS)

    Korteniemi, V.; Haapalehto, T.; Puustinen, M.

    1995-01-01

    Several experiments were performed with the VEERA facility to simulate reflooding and boil-off phenomena in a VVER-440 like rod bundle. The objective of these experiments was to get experience of a full-scale bundle behavior and to create a database for verification of VVER type core models used with modern thermal-hydraulic codes. The VEERA facility used in the experiments is a scaled-down model of the Russian VVER-440 type pressurized water reactors used in Loviisa, Finland. The test section of the facility consists of one full-scale copy of a VVER-440 reactor rod bundle with 126 full-length electrically heated rod simulators. Bottom and top-down reflooding, different modes of emergency core cooling (ECC) injection and the effect of heating power on the heat-up of the rods was studied. In this paper the results of calculations simulating two reflood and one boil-off experiment with the French CATHARE2 thermal-hydraulic code are also presented. Especially the performance of the recently implemented top-down reflood model of the code was studied

  19. Reflooding and boil-off experiments in a VVER-440 like rod bundle and analyses with the CATHARE code

    Energy Technology Data Exchange (ETDEWEB)

    Korteniemi, V.; Haapalehto, T. [Lappeenranta Univ. of Technology (Finland); Puustinen, M. [VTT Energy, Lappeenranta (Finland)

    1995-09-01

    Several experiments were performed with the VEERA facility to simulate reflooding and boil-off phenomena in a VVER-440 like rod bundle. The objective of these experiments was to get experience of a full-scale bundle behavior and to create a database for verification of VVER type core models used with modern thermal-hydraulic codes. The VEERA facility used in the experiments is a scaled-down model of the Russian VVER-440 type pressurized water reactors used in Loviisa, Finland. The test section of the facility consists of one full-scale copy of a VVER-440 reactor rod bundle with 126 full-length electrically heated rod simulators. Bottom and top-down reflooding, different modes of emergency core cooling (ECC) injection and the effect of heating power on the heat-up of the rods was studied. In this paper the results of calculations simulating two reflood and one boil-off experiment with the French CATHARE2 thermal-hydraulic code are also presented. Especially the performance of the recently implemented top-down reflood model of the code was studied.

  20. Data report of ROSA/LSTF experiment SB-HL-12. 1% hot leg break LOCA with SG depressurization and gas inflow

    International Nuclear Information System (INIS)

    Takeda, Takeshi

    2016-01-01

    An experiment SB-HL-12 was conducted on February 24, 1998 using the Large Scale Test Facility (LSTF) in the Rig of Safety Assessment-V (ROSA-V) Program. The ROSA/LSTF experiment SB-HL-12 simulated a 1% hot leg small-break loss-of-coolant accident in a pressurized water reactor under assumptions of total failure of high pressure injection system and non-condensable gas (nitrogen gas) inflow to the primary system from accumulator (ACC) tanks of emergency core cooling system (ECCS). Steam generator (SG) secondary-side depressurization by fully opening the relief valves in both SGs as an accident management (AM) action was initiated immediately after maximum surface temperature of simulated fuel rod reached 600 K. Auxiliary feedwater injection into the secondary-side of both SGs was started immediately after the initiation of AM action. After the onset of AM action due to first core uncovery by core boil-off, the primary pressure decreased following the SG secondary-side pressure, causing core mixture level swell. The fuel rod surface temperature then increased up to 635 K. Second core uncovery by core boil-off took place before loop seal clearing (LSC) induced by steam condensation on ACC coolant injected into cold legs. The core liquid level recovered rapidly after the LSC. The fuel rod surface temperature then increased up to 696 K. The pressure difference became larger between the primary and SG secondary sides after the ACC tanks started to discharge nitrogen gas, which resulted in no actuation of LPI system of ECCS during the experiment. Third core uncovery by core boil-off occurred during the reflux condensation in the SG U-tubes under nitrogen gas inflow. The core power was automatically decreased by the LSTF core protection system when the maximum fuel rod surface temperature exceeded 908 K. The obtained data would be useful to define the conditions for counterpart testing of other integral test facilities to address scaling problems through thermal

  1. Nietzsche como destino da filosofia e da humanidade? interpretação contextual do § 1 do capítulo "por que sou um destino", de ecce homo

    Directory of Open Access Journals (Sweden)

    Werner Stegmaier

    2010-01-01

    Full Text Available The following translation is a reduced and revised version of the paper Schicksal Nietzsche? Zu Nietzsches Selbsteinschätzung als Schicksal der Philosophie und der Menschheit (Ecce Homo, Warum ich ein Schicksal bin §1" - originally published in Nietzsche-Studien 37 (2008 - which was specially prepared to be presented in lecture organized by the Grupo de Pesquisa Spinoza & Nietzsche (Spinoza & Nietzsche research group - SpiN, in the Universidade Federal do Rio de Janeiro (Rio de Janeiro's Federal University, on September 14, 2009. In the text, the autor employs his own philological-hermeneutical methodology, which is called contextual interpretation, in the purpose to clarify the concepts of the first aphorism from "Why I am a destiny", from Ecce Homo, in its own context, in the context of Ecce Homo and in the context of the entire work from Nietzsche.

  2. Full scale calcium bromide injection with subsequent mercury oxidation and removal within wet flue gas desulphurization system: Experience at a 700 MW coal-fired power facility

    Science.gov (United States)

    Berry, Mark Simpson

    The Environmental Protection Agency promulgated the Mercury and Air Toxics Standards rule, which requires that existing power plants reduce mercury emissions to meet an emission rate of 1.2 lb/TBtu on a 30-day rolling average and that new plants meet a 0.0002 lb/GWHr emission rate. This translates to mercury removals greater than 90% for existing units and greater than 99% for new units. Current state-of-the-art technology for the control of mercury emissions uses activated carbon injected upstream of a fabric filter, a costly proposition. For example, a fabric filter, if not already available, would require a 200M capital investment for a 700 MW size unit. A lower-cost option involves the injection of activated carbon into an existing cold-side electrostatic precipitator. Both options would incur the cost of activated carbon, upwards of 3M per year. The combination of selective catalytic reduction (SCR) reactors and wet flue gas desulphurization (wet FGD) systems have demonstrated the ability to substantially reduce mercury emissions, especially at units that burn coals containing sufficient halogens. Halogens are necessary for transforming elemental mercury to oxidized mercury, which is water-soluble. Plants burning halogen-deficient coals such as Power River Basin (PRB) coals currently have no alternative but to install activated carbon-based approaches to control mercury emissions. This research consisted of investigating calcium bromide addition onto PRB coal as a method of increasing flue gas halogen concentration. The treated coal was combusted in a 700 MW boiler and the subsequent treated flue gas was introduced into a wet FGD. Short-term parametric and an 83-day longer-term tests were completed to determine the ability of calcium bromine to oxidize mercury and to study the removal of the mercury in a wet FGD. The research goal was to show that calcium bromine addition to PRB coal was a viable approach for meeting the Mercury and Air Toxics Standards rule

  3. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  4. Injecting drug use: Gendered risk.

    Science.gov (United States)

    Zahnow, Renee; Winstock, Adam R; Maier, Larissa J; Levy, Jay; Ferris, Jason

    2018-06-01

    Research demonstrates gender related differences in drug-use practices and risk behaviours. Females' structural vulnerability stemming from traditional gender roles and gender-power relations may enhance their propensity to experience injecting related risk. In this paper we explore gender differences in injection practices at the initiation event, during the first year of injecting and in the most recent 12-month period, to inform more effective harm reduction strategies. Data used in this study were drawn from the Global Drug Survey 2015. The study employs chi-square and logistic regression to assess gender differences in injection behaviours in a sample of current injectors residing in six global regions: North-West Europe; Southern Eastern Europe; North America. South America and Oceania. Females were more likely than males to report being injected by an intimate partner at initiation (OR = 4.4, 95%CI: 2.2-8.8), during the first year of injecting (OR = 4.8, 95% CI: 2.4-9.3) and in the most recent 12-month period (OR = 2.5, 95%CI: 1.0-6.2). Females reported greater difficulties accessing sterile equipment (X 2 (2,N = 453) = 8.2, p = 0.02) and were more likely to share injecting equipment than males (X 2 (1,N = 463) = 3.9, p = 0.05). Our findings highlight females' continued dependence on their intimate partner to administer the injection into the first year of their injecting career. Females remained more likely than males to rely on intimate partners for injection during the most recent 12-month period. Females report greater difficulties in sourcing sterile equipment and are more likely to share injecting equipment. We suggest that these findings reflect the broader social structure in which females are disempowered through traditional gender roles and the lack of gender appropriate harm reduction services. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Pellet injection and toroidal confinement

    International Nuclear Information System (INIS)

    1989-12-01

    The proceedings of a technical committee meeting on pellet injection and toroidal confinement, held in Gut Ising, Federal Republic of Germany, 24-26 October, 1988, are given in this report. Most of the major fusion experiments are using pellet injectors; these were reported at this meeting. Studies of confinement, which is favorably affected, impurity transport, radiative energy losses, and affects on the ion temperature gradient instability were given. Studies of pellet ablation and effects on plasma profiles were presented. Finally, several papers described present and proposed injection guns. Refs, figs and tabs

  6. "Injection first": a unique group of injection drug users in Tijuana, Mexico.

    Science.gov (United States)

    Morris, Meghan D; Brouwer, Kimberly C; Lozada, Remedios M; Gallardo, Manuel; Vera, Alicia; Strathdee, Steffanie A

    2012-01-01

    Using baseline data from a study of injection drug users (IDUs) in Tijuana, Mexico (N = 1,052), we identified social and behavioral factors associated with injecting at the same age or earlier than other administration routes of illicit drug use (eg, "injection first") and examined whether this IDU subgroup had riskier drug using and sexual behaviors than other IDUs. Twelve-percent "injected first." Characteristics independently associated with a higher odds of "injection first" included being younger at first injection, injecting heroin as their first drug, being alone at the first injection episode, and having a sexual debut at the same age or earlier as when they initiated drug use; family members' illicit drug use was associated with lower odds of injecting first. When adjusting for age at first injection and number of years injecting, "injection first" IDUs had lower odds of ever overdosing, and ever trading sex. On the other hand, they were less likely to have ever been enrolled in drug treatment, and more commonly obtained their syringes from potentially unsafe sources. In conclusion, a sizable proportion of IDUs in Tijuana injected as their first drug using experience, although evidence that this was a riskier subgroup of IDUs was inconclusive.  Copyright © American Academy of Addiction Psychiatry.

  7. The influence of plasma horizontal position on the neutron rate and flux of neutral atoms in injection heating experiment on the TUMAN-3M tokamak

    Science.gov (United States)

    Kornev, V. A.; Chernyshev, F. V.; Melnik, A. D.; Askinazi, L. G.; Wagner, F.; Vildjunas, M. I.; Zhubr, N. A.; Krikunov, S. V.; Lebedev, S. V.; Razumenko, D. V.; Tukachinsky, A. S.

    2013-11-01

    Horizontal displacement of plasma along the major radius has been found to significantly influence the fluxes of 2.45 MeV DD neutrons and high-energy charge-exchange atoms from neutral beam injection (NBI) heated plasma of the TUMAN-3M tokamak. An inward shift by Δ R = 1 cm causes 1.2-fold increase in the neutron flux and 1.9-fold increase in the charge-exchange atom flux. The observed increase in the neutron flux is attributed to joint action of several factors-in particular, improved high-energy ion capture and confinement and, probably, decreased impurity inflow from the walls, which leads to an increase in the density of target ions. A considerable increase in the flux of charge-exchange neutrals in inward-shifted plasma is due to the increased number of captured high-energy ions and, to some extent, the increased density of the neutral target. As a result of the increase in the content of high-energy ions, the central ion temperature T i (0) increased from 250 to 350 eV. The dependence of the neutron rate on major radius R 0 should be taken into account when designing compact tokamak-based neutron sources.

  8. Sodium Ferric Gluconate Injection

    Science.gov (United States)

    Sodium ferric gluconate injection is used to treat iron-deficiency anemia (a lower than normal number of ... are also receiving the medication epoetin (Epogen, Procrit). Sodium ferric gluconate injection is in a class of ...

  9. Calcitonin Salmon Injection

    Science.gov (United States)

    Calcitonin salmon injection is used to treat osteoporosis in postmenopausal women. Osteoporosis is a disease that causes bones to weaken and break more easily. Calcitonin salmon injection is also used to treat Paget's disease ...

  10. Iron Dextran Injection

    Science.gov (United States)

    Iron dextran injection is used to treat iron-deficiency anemia (a lower than normal number of red blood cells ... treated with iron supplements taken by mouth. Iron dextran injection is in a class of medications called ...

  11. Aminocaproic Acid Injection

    Science.gov (United States)

    Aminocaproic acid injection is used to control bleeding that occurs when blood clots are broken down too quickly. This ... the baby is ready to be born). Aminocaproic acid injection is also used to control bleeding in ...

  12. Deoxycholic Acid Injection

    Science.gov (United States)

    Deoxycholic acid injection is used to improve the appearance and profile of moderate to severe submental fat ('double chin'; fatty tissue located under the chin). Deoxycholic acid injection is in a class of medications called ...

  13. Cluster beam injection

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Fois, M.

    1978-01-01

    Areas of possible applications of cluster injection are discussed. The deposition inside the plasma of molecules, issued from the dissociation of the injected clusters, has been computed. Some empirical scaling laws for the penetration are given

  14. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  15. FIX-II/2032, BWR Pump Trip Experiment 2032, Simulation Mass Flow and Power Transients

    International Nuclear Information System (INIS)

    1988-01-01

    1 - Description of test facility: In the FIX-II pump trip experiments, mass flow and power transients were simulated subsequent to a total loss of power to the recirculation pumps in an internal pump boiling water reactor. The aim was to determine the initial power limit to give dryout in the fuel bundle for the specified transient. In addition, the peak cladding temperature was measured and the rewetting was studied. 2 - Description of test: Pump trip experiment 2032 was a part of test group 2, i.e. the mass flow transient was to simulate the pump coast down with a pump inertia of 11.3 kg.m -2 . The initial power in the 36-rod bundle was 4.44 MW which gave dryout after 1.4 s from the start of the flow transient. A maximum rod cladding temperature of 457 degrees C was measured. Rewetting was obtained after 7.6 s. 3 - Experimental limitations or shortcomings: No ECCS injection systems

  16. Systematic evaluation program review of NRC Safety Topic VI-7.3 associated with the electrical, instrumentation and control portions of the ECCS actuation system for the Dresden II Nuclear Power Plant

    International Nuclear Information System (INIS)

    St Leger-Barter, G.

    1980-11-01

    This report documents the technical evaluation and review of NRC Safety Topic VI-7.A.3, associated with the electrical, instrumentation, and control portions of the classification of the ECCS actuation system for the Dresden II nuclear power plant, using current licensing criteria

  17. LABORATORY SCALE STEAM INJECTION TREATABILITY STUDIES

    Science.gov (United States)

    Laboratory scale steam injection treatability studies were first developed at The University of California-Berkeley. A comparable testing facility has been developed at USEPA's Robert S. Kerr Environmental Research Center. Experience has already shown that many volatile organic...

  18. Aplicação das técnicas de planejamento e análise de experimentos no processo de injeção plástica Application design of experiments in the injection molding process

    Directory of Open Access Journals (Sweden)

    Edwin V. Cardoza Galdamez

    2004-04-01

    Full Text Available Experimentos industriais são realizados pelas empresas com o intuito de melhorar o desempenho dos produtos e os processos de fabricação. Nesse sentido, este trabalho tem por objetivo estudar e aplicar as técnicas de planejamento e análise de experimentos na melhoria da qualidade industrial. Especificamente são aplicadas as técnicas de planejamento Fatorial Fracionado 2k-p, Metodologia de Superfície de Resposta e Análise de Variância, em um processo de moldagem por injeção plástica. Com essa pesquisa experimental foi possível identificar os níveis ótimos de regulagem e os parâmetros mais importantes da injeção plástica: temperatura da máquina e pressão de injeção. Para finalizar é avaliado o procedimento de implementação das técnicas de experimentação e as dificuldades práticas encontradas na empresa.Industrial experiments are made by companies in order to improve the quality characteristics of products and production processes. In this sense, the objective of this paper is to study and apply the design of experiments in the industrial quality improvement. In addition, as a part of the objective, an application of the techniques of design Fractional Factorial 2k-p, Analysis of Variance and Response Surface Methodology is done. It is focused in an injection molding process applied by a company, that makes and trades plastic products for the civil construction. Using this experimental study, the most important parameters of plastic injection are identified: machine temperature and injection pressure. At the same time, the optimal levels of adjustment of these parameters are determined. From this study, it is evaluated both the implantation procedures of the designs of experiments as well as the difficulties faced. Also, this study tries to contribute to the university-company relationship.

  19. The broadening application of chemodenervation in X-linked dystonia-parkinsonism (Part II): an open-label experience with botulinum toxin-A (Dysport®) injections for oromandibular, lingual, and truncal-axial dystonias.

    Science.gov (United States)

    Rosales, Raymond L; Ng, Arlene R; Santos, Mary Mildred Delgado-Delos; Fernandez, Hubert H

    2011-01-01

    While the majority of chemodenervation clinics worldwide typically use botulinum toxins for the treatment of common conditions such as blepharopsams, cervical dystonia, limb dystonia, and spasticity, the unusually high concentration of X-linked dystonia-parkinsonism (XDP) has allowed us to collect and describe our experience in the use of botulinum toxin type A (BoNT-A) on rarer dystonic patterns. BoNT-A (Dysport®) was injected in a total 109 dystonias of XDP. Our cohort included: 50 cases in the oromandibular area (jaw opening: 32 cases, jaw closing: 12 cases, and jaw deviation: 6 cases); 35 cases in the lingual area (tongue protrusion: 27 cases and tongue curling: 8 cases); and, 24 cases in the truncal-axial area (flexor: 12 cases, extensor: 7 cases, and lateral-extensor: 5 cases). Interestingly, pain, often a nonprominent symptom of dystonias, was frequently reported in 40/50 XDP cases with oromandibular dystonia and 18/24 XDP cases with truncal-axial dystonia. All BoNT-A procedures were performed under electromyography guidance. A "high potency, low dilution" BoNT-A protocol was applied for oromandibular, lingual, cranial, cervical, and distal limb dystonias; whereas for dystonias of the abdominal, paraspinal, and proximal limb muscles, a "low potency, high dilution" BoNT-A injection protocol was applied. Outcomes measures included: the global dystonia rating scale (DRS) and pain visual analog scale (VAS) reduction at week 4; duration of BoNT-A effects; and, side effect profile. The median DRS score after 4 weeks was 3 ("substantial improvement") for oromandibular and lingual dystonias and 2 ("moderate improvement") for truncal-axial dystonias. Pain reduction was significantly reduced (75%-80% in oromandibular; 30%-80% in truncal-axial dystonias). The median duration of BoNT-A effect was 16 weeks for oromandibular, 12 weeks for lingual, and 11 weeks for truncal-axial dystonias. Compared to a generally safe and well-tolerated BoNT-A injections for truncal

  20. Experiment data report for semiscale Mod-1 test S-01-1B (isothermal blowdown with core resistance simulator)

    International Nuclear Information System (INIS)

    Crapo, H.S.; Jensen, M.F.; Sackett, K.E.; Zender, S.N.

    1975-05-01

    Recorded test data are presented for Test S-01-1B of the semiscale Mod-1 isothermal blowdown test series. System hardware is representative of the LOFT design, selected using volumetric scaling methods, and initial conditions duplicate those identified for the LOFT nonnuclear tests. Test S-01-1B is a repeat of Test S-01-1 with the exception that simulated ECC was injected into the cold leg of the intact loop rather than into the inlet annulus of the downcomer. The principal objective of Test S-01-1B was to determine whether a different ECC injection would significantly alter the system response during the period of ECC injection. Test S-01-1B was conducted from an initial temperature of 541 0 F and an initial pressure of 1630 psig. A simulated intermediate size double-ended hot leg break (0.00145 ft 2 break area on each end) was used to investigate the system response to a slow de-pressurization transient. An orificed structure was used in the pressure vessel to simulate the LOFT core simulator. Following the blowdown portion of Test S-01-1B, coolant spray was introduced into the pressure suppression tank to determine the response of the pressure suppression system. (U.S.)

  1. SQL injection detection system

    OpenAIRE

    Vargonas, Vytautas

    2017-01-01

    SQL injection detection system Programmers do not always ensure security of developed systems. That is why it is important to look for solutions outside being reliant on developers. In this work SQL injection detection system is proposed. The system analyzes HTTP request parameters and detects intrusions. It is based on unsupervised machine learning. Trained by regular request data system detects outlier user parameters. Since training is not reliant on previous knowledge of SQL injections, t...

  2. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented including the following: Raft River Valley, Salton Sea, East Mesa, Otake, Hatchobaru, and Ahuachapan geothermal fields.

  3. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  4. Urinary incontinence - injectable implant

    Science.gov (United States)

    ... repair; ISD repair; Injectable bulking agents for stress urinary incontinence ... and disorders: physiology of micturition, voiding dysfunction, urinary incontinence, urinary tract infections, and painful bladder syndrome. In: Lobo ...

  5. Experiment data report for semiscale Mod-1 Test S-01-5 (isothermal blowdown with core resistance simulator)

    International Nuclear Information System (INIS)

    Zender, S.N.; Crapo, H.S.; Jensen, M.F.; Sackett, K.E.

    1975-04-01

    Recorded test data are presented for Test S-01-5 of the semiscale Mod-1 isothermal blowdown test series. Test S-01-5 is one of several semiscale Mod-1 experiments which are counterparts of the LOFT nonnuclear experiments. System hardware is representative of LOFT with the design based on volumetric scaling methods and with initial conditions duplicating those identified for LOFT nonnuclear tests. Test S-01-5 was conducted with the secondary side of the steam generator pressurized with nitrogen gas in order to effectively eliminate heat transfer from the steam generator during blowdown and thereby to investigate the effect on overall system behavior of heat transfer from the steam generator. An orificed structure was used in the pressure vessel to simulate the LOFT core simulator. The test was initiated at isothermal conditions of 2270 psig and 540 0 F by a simulated offset shear of the cold leg broken loop piping. During system depressurization, coolant was injected into the cold leg of the operating loop to simulate emergency core cooling (ECC). Following the blowdown portion of the test, coolant spray was introduced into the pressure suppression tank to determine the response of the pressure suppression system. The uninterpreted data from Test S-01-5 and the reference material needed for future data analysis and test results reporting activities are presented. The data, presented in the form of graphs in engineering units, have been analyzed only to the extent necessary to assure that they are reasonable and consistent. (U.S.)

  6. Initial clinical experience with a quadrupole butterfly coil for spinal injection interventions in an open MRI system at 1.0 tesla.

    Science.gov (United States)

    Jonczyk, Martin; Hamm, Bernd; Heinrich, Andreas; Thomas, Andreas; Rathke, Hendrik; Schnackenburg, Bernhard; Güttler, Felix; Teichgräber, Ulf K M; de Bucourt, Maximilian

    2014-02-01

    To report our initial clinical experience with a new magnetic resonance imaging (MRI) quadrupole coil that allows interventions in prone position. Fifteen patients (seven women, eight men; average age, 42.8 years) were treated in the same 1.0-Tesla Panorama High Field Open (HFO) MRI system (Panorama HFO) using a quadrupole butterfly coil (Bfly) and compared with 15 patients matched for sex, age, and MR intervention using the MultiPurposeL coil (MPL), performed in conventional lateral decubitus position (all, Philips Medical Systems, Best, The Netherlands). All interventions were performed with a near-real-time proton density turbo spin echo (PD TSE) sequence (time to repeat/time to echo/flip angle/acquisition time, 600 ms/10 ms/90°/3 s/image). Qualitative and quantitative image analyses were performed, including signal intensity, signal-to-noise and contrast-to-noise ratio (SNR, CNR), contrast, and full width at half maximum (FWHM) measurements. Contrast differed significantly between the needle and muscles (Bfly 0.27/MPL 0.17), as well as the needle and periradicular fat (0.13/0.24) during the intervention (both, p=0.029), as well as the CNR between muscles and the needle (10.61/5.23; p=0.010), although the FWHM values did not (2.4/2.2; p=0.754). The signal intensity of the needle in interventional imaging (1152.9/793.2; p=0.006) and the postinterventional SNR values of subcutaneous fat (15.3/28.6; p=0.007), muscles (6.6/11.8; p=0.011), and the CNR between these tissues (8.7/17.5; p=0.004) yielded significant differences. The new coil is a valid alternative for MR-guided interventions in an open MRI system at 1.0 tesla, especially if patients cannot (or prefer not to) be in a lateral decubitus position or if prone positioning yields better access to the target zone.

  7. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    Experiences with injecting geothermal fluids have identified technical problems associated with geothermal waste disposal. This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented, including: Raft River, Salton Sea, East Mesa, Otake and Hatchobaru in Japan, and Ahuachapan in El Salvador. Hydrogeologic and design/operational factors affecting the success of an injection program are identified. Hydrogeologic factors include subsidence, near-surface effects of injected fluids, and seismicity. Design/operational factors include hydrodynamic breakthrough, condition of the injection system and reservoir maintenance. Existing and potential effects of production/injection on these factors are assessed.

  8. Deuterium pellet injection in the TFR Tokamak

    International Nuclear Information System (INIS)

    Lazare, O.

    1985-07-01

    Injecting fresh fuel deep inside the plasma of a thermonuclear reactor appears to be necessary; the only way to do that is to inject fast solid deuterium pellets. The existing theoretical, technical and experimental aspects of this method are presented. The experiments on TFR have confirmed that injecting pellets is technically feasible; a new kind of injector is presented. The injection does not degrade stability nor confinement of the plasma. The study of the transient phenomena occuring during the injection has proved to be an efficient way to investigate particles and energy transport in the discharge; in particular, a fast transport phenomenon, similar to those occuring during disruptions, has been studied in details. Conclusions about disruptions are drawn. (Ref 101) [fr

  9. Electron injection in microtron

    International Nuclear Information System (INIS)

    Axinescu, S.

    1977-01-01

    A review of the methods of injecting electrons in the microtron is presented. A special attention is paid to efficient injection systems developed by Wernholm and Kapitza. A comparison of advantages and disadvantages of both systems is made in relation to the purpose of the microtron. (author)

  10. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  11. Dimethyl Ether Injection Studies

    DEFF Research Database (Denmark)

    Sorenson, Spencer C.; Glensvig, Michael; Abata, Duane L.

    1998-01-01

    A series of preliminary investigations has been performed in order to investigate the behavior of DME in a diesel injection environment. These studies have in-cluded visual observations of the spray penetration and angles for high pressure injection into Nitrogen using conventional jerk pump inje...

  12. Pellet injection into ASDEX upgrade plasmas

    International Nuclear Information System (INIS)

    Lang, P.T.; Zohm, H.; Buechl, K.; Fuchs, J.C.; Gehre, O.; Gruber, O.; Lang, R.S.; Mertens, V.; Neuhauser, J.; Salzmann, H.

    1996-04-01

    This work comprises results obtained using the new centrifuge injection system for the two first years of pellet injection experiments at Asdex Upgrade until the end of the 1995 experimental campaign. The main aim of the pellet injection investigation is to develop scenarios allowing for a more flexible plasma density control means of injection of cryogenic solid hydrogen pellets. Efforts have been made to develop scenarios allowing more flexible plasma density control by injecting cryogenic solid hydrogen pellets. While the injection of pellets during ohmic discharges was found to be most efficient and also improves the plasma performance, increasing the auxiliary heating power causes a detoriation of the pellet fuelling efficiency. A further strong reduction of the pellet fuelling efficiency by an additional process was observed for the more reactor-relevant conditions of shallow particle deposition during H-mode phases. With injection during type I ELMy H-mode phases, each pellet was found to trigger the release of an ELM and therefore cause particle losses mainly from the edge region. In the type I ELMy H-mode, only sufficient pellet penetration allowed noticeable, persistent particle deposition in the plasma by the pellets. Applying adequate pellet injection conditions and favourable scenarios using combined pellet/gas puff refuelling, significant density ramp-up to densities exceeding the empirical Greenwald limit by up to a factor of two was achieved even for strongly heated H-mode plasmas. (orig.)

  13. Simulation of a severe accident at a typical PWR due to break of a hot leg ECCS line using MELCOR code

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Min; Sabundjian, Gaianê, E-mail: smlee@ipen.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    The aim of this work was to simulate a severe accident at a typical PWR caused by break in Emergency Core Cooling System (ECCS) line of a hot leg using the MELCOR code. The nodalization of this typical PWR was elaborated by the Global Research for Safety (GRS) and provided to the CNEN for analysis of the severe accidents at the Angra 2, which is similar to that PWR. Although both of them are not identical the results obtained for that typical PWR may be valuable because of the lack of officially published calculation for Angra 2. Relevant parameters such as pressure, temperature and water level in various control volumes after the break in the hot leg were calculated as well as degree of core degradation and hydrogen concentration in containment. The result obtained in this work could be considered satisfactory in the sense that the physical phenomena reproduced by the simulation were in general very reasonable, and most of the events occurred within acceptable time intervals. However, the uncertainty analysis was not carried out in this work. Furthermore, this scenario could be used as a base for the study of the effectiveness of some preventive or/and mitigating measures of Severe Accident Management (SAMG) by adding associated conditions for each measure in its input. (author)

  14. Simulation of a severe accident at a typical PWR due to break of a hot leg ECCS line using MELCOR code

    International Nuclear Information System (INIS)

    Lee, Seung Min; Sabundjian, Gaianê

    2017-01-01

    The aim of this work was to simulate a severe accident at a typical PWR caused by break in Emergency Core Cooling System (ECCS) line of a hot leg using the MELCOR code. The nodalization of this typical PWR was elaborated by the Global Research for Safety (GRS) and provided to the CNEN for analysis of the severe accidents at the Angra 2, which is similar to that PWR. Although both of them are not identical the results obtained for that typical PWR may be valuable because of the lack of officially published calculation for Angra 2. Relevant parameters such as pressure, temperature and water level in various control volumes after the break in the hot leg were calculated as well as degree of core degradation and hydrogen concentration in containment. The result obtained in this work could be considered satisfactory in the sense that the physical phenomena reproduced by the simulation were in general very reasonable, and most of the events occurred within acceptable time intervals. However, the uncertainty analysis was not carried out in this work. Furthermore, this scenario could be used as a base for the study of the effectiveness of some preventive or/and mitigating measures of Severe Accident Management (SAMG) by adding associated conditions for each measure in its input. (author)

  15. Correlated electron capture in the impact parameter and final projectile charge-state dependence of ECC cusp production in 0.53 MeV u-1 F8+ + Ne

    International Nuclear Information System (INIS)

    Skutlartz, A.; Hagmann, S.; Schmidt-Boecking, H.

    1988-01-01

    The impact parameter dependence of ECC cusp electron production in collisions of fast, highly charged ions with atoms is investigated by measuring the scattered projectiles in coincidence with cusp electrons emitted at 0 0 with respect to the beam axis. The absolute probabilities for ECC cusp production show a maximum at b ≅ 0.10 au, decrease strongly for smaller impact parameters and more gently toward larger impact parameters. In addition the final charge state of the scattered projectile is also determined simultaneously for each collision event. The probabilities, as a function of the projectile final charge state, are large for the case where at least one or more electrons are simultaneously captured into bound states of the projectile, but are surprisingly small for collisions in which a projectile did not capture an electron into a bound state. (author)

  16. Survey of Botulinum Toxin Injections in Anticoagulated Patients: Korean Physiatrists' Preference in Controlling Anticoagulation Profile Prior to Intramuscular Injection.

    Science.gov (United States)

    Jang, Yongjun; Park, Geun-Young; Park, Jihye; Choi, Asayeon; Kim, Soo Yeon; Boulias, Chris; Phadke, Chetan P; Ismail, Farooq; Im, Sun

    2016-04-01

    To evaluate Korean physiatrists' practice of performing intramuscular botulinum toxin injection in anticoagulated patients and to assess their preference in controlling the bleeding risk before injection. As part of an international collaboration survey study, a questionnaire survey was administered to 100 Korean physiatrists. Physiatrists were asked about their level of experience with botulinum toxin injection, the safe international normalized ratio range in anticoagulated patients undergoing injection, their tendency for injecting into deep muscles, and their experience of bleeding complications. International normalized ratio injection by 41% of the respondents. Thirty-six respondents replied that the international normalized ratio should be lowered to sub-therapeutic levels before injection, and 18% of the respondents reported that anticoagulants should be intentionally withheld and discontinued prior to injection. In addition, 20%-30% of the respondents answered that they were uncertain whether they should perform the injection regardless of the international normalized ratio values. About 69% of the respondents replied that they did have any standardized protocols for performing botulinum toxin injection in patients using anticoagulants. Only 1 physiatrist replied that he had encountered a case of compartment syndrome. In accordance with the lack of consensus in performing intramuscular botulinum toxin injection in anticoagulated patients, our survey shows a wide range of practices among many Korean physiatrists; they tend to avoid botulinum toxin injection in anticoagulated patients and are uncertain about how to approach these patients. The results of this study emphasize the need for formulating a proper international consensus on botulinum toxin injection management in anticoagulated patients.

  17. Clinical experience with progestogen only injectable contraceptive ...

    African Journals Online (AJOL)

    Eight hundred and fifty six (79.6%) were lost to follow up while 57 discontinued POIC use due to desire for pregnancy, implant insertion and complications such as weight gain, giving a discontinuation rate of 5.30%. No pregnancy was reported among these women during this period, giving a pearl pregnancy index of zero.

  18. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  19. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  20. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  1. Performance of a remote steering antenna for ECRH/ECCS applications using 4-wall corrugated square waveguide

    International Nuclear Information System (INIS)

    Kasparek, W.; Gantenbein, G.; Plaum, B.; Wacker, R.; Filipovic, E.; Chirkov, A.V.; Denisov, G.G.; Kuzikov, S.V.; Ohkubo, K.; Hollmann, F.; Wagner, D.

    2003-01-01

    For the upper ECW launcher on ITER, the use of a 'remote steering antenna' based on the imaging properties of rectangular waveguides is planned. To characterise launchers of this type, low-power experiments on a 4-side corrugated square waveguide with a scanning mirror at the input of the waveguide were performed in the frequency range of 140 to 160 GHz. It is shown, that elliptical polarisation needed for ECCD can be transmitted without depolarization. The usable steering range of the antenna is at least -10 angle < φ ≤ + 10 angle. Experiments with the scanning plane in the diagonal of the square waveguide led to a negligible increase the scanning range, and lobes in the upward and downward direction are detected at larger scanning angles. Mitre bends can be integrated into the waveguide without prohibitive extra loss, which is demonstrated by far-field measurements. Detailed calorimetric measurements for this set up confirm this statement for the polarisation perpendicular to the scanning plane, whereas extra loss is measured for the parallel polarisation. Results are discussed and are compared to theory. (authors)

  2. Emulsion sheet doublets as interface trackers for the OPERA experiment

    CERN Document Server

    Anokhina, A.; Ariga, A.; Arrabito, L.; Autiero, D.; Badertscher, A.; Bay, F.; Greggio, F.Bersani; Bertolin, A.; Besnier, M.; Bick, D.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Carrara, E.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Consiglio, L.; Cozzi, M.; Cuha, V.; Dal Corso, F.; D'Amato, G.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Di Troia, C.; Dmitrievski, S.; Dominjon, A.; Dracos, Marcos; Duchesneau, D.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, Antonio; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Frekers, D.; Fukuda, T.; Galkin, V.I.; Galkin, V.A.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Goldberg, J.; Golubkov, D.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gusev, G.; Gustavino, C.; Hagner, Caren; Hara, T.; Hierholzer, M.; Hiramatsu, S.; Hoshino, Kaoru; Ieva, M.; Jakovcic, K.; Janicsko Csathy, J.; Janutta, B.; Jollet, C.; Juget, F.; Kawai, T.; Kazuyama, M.; Kim, S.H.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Laktineh, I.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, Andrea; Lutter, G.; Manai, K.; Mandrioli, G.; Marotta, A.; Marteau, J.; Matsuo, T.; Matsuoka, H.; Mauri, N.; Meisel, F.; Meregaglia, A.; Messina, M.; Migliozzi, P.; Mikado, S.; Miyamoto, S.; Monacelli, Piero; Morishima, Kunihiro; Moser, U.; Muciaccia, Maria Teresa; Naganawa, N.; Naka, T.; Nakamura, M.; Nakamura, T.; Nakano, T.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Osedlo, V.; Ossetski, D.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pilipenko, V.; Pistillo, C.; Polukhina, N.; Pozzato, M.; Pretzl, Klaus P.; Publichenko, P.; Pupilli, F.; Roganova, T.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryazhskaya, O.; Ryzhikov, D.; Sato, O.; Sato, Y.; Saveliev, V.; Sazhina, G.; Schembri, A.; Scotto Lavina, L.; Shibuya, H.; Simone, S.; Sioli, Max; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, Paolo Emilio; Sugonyaev, V.; Taira, Y.; Takahashi, S.; Tenti, M.; Terranova, F.; Tezuka, I.; Tioukov, V.; Tolun, P.; Tsarev, V.; Tufanli, S.; Ushida, N.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Wurtz, J.; Yoon, C.S.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, Amina; Zimmermann, R.

    2008-01-01

    New methods for efficient and unambiguous interconnection between electronic counters and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment, that aims at detecting oscillations between mu neutrino and tau neutrino in the CNGS neutrino beam, is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector, on-site large-scale treatments of the emulsions ("refreshing") have been applied. Changeable Sheet (CSd) packages, each made of a doublet of emulsion films, have been designed, assembled and coupled to the OPERA target units ("ECC bricks"). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronic...

  3. Hip joint injection

    Science.gov (United States)

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  4. Premixed direct injection disk

    Science.gov (United States)

    York, William David; Ziminsky, Willy Steve; Johnson, Thomas Edward; Lacy, Benjamin; Zuo, Baifang; Uhm, Jong Ho

    2013-04-23

    A fuel/air mixing disk for use in a fuel/air mixing combustor assembly is provided. The disk includes a first face, a second face, and at least one fuel plenum disposed therebetween. A plurality of fuel/air mixing tubes extend through the pre-mixing disk, each mixing tube including an outer tube wall extending axially along a tube axis and in fluid communication with the at least one fuel plenum. At least a portion of the plurality of fuel/air mixing tubes further includes at least one fuel injection hole have a fuel injection hole diameter extending through said outer tube wall, the fuel injection hole having an injection angle relative to the tube axis. The invention provides good fuel air mixing with low combustion generated NOx and low flow pressure loss translating to a high gas turbine efficiency, that is durable, and resistant to flame holding and flash back.

  5. Imipenem and Cilastatin Injection

    Science.gov (United States)

    Imipenem and cilastatin injection is used to treat certain serious infections that are caused by bacteria, including ... area), gynecological, blood, skin, bone, and joint infections. Imipenem is in a class of medications called carbapenem ...

  6. Quinupristin and Dalfopristin Injection

    Science.gov (United States)

    ... are in a class of medications called streptogramin antibiotics. They work by killing bacteria that cause infections.Antibiotics such as quinupristin and dalfopristin injection will not work for colds, flu, or other viral infections. Taking ...

  7. Botulinum toxin injection - larynx

    Science.gov (United States)

    Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...

  8. The PEP injection system

    International Nuclear Information System (INIS)

    Brown, K.L.; Avery, R.T.; Peterson, J.M.

    1988-01-01

    A system to transport 10-to-15-GeV electron and positron beams from the Stanford Linear Accelerator and to inject them into the PEP storage ring under a wide variety of lattice configurations has been designed. Optically, the transport line consists of three 360/degree/ phase-shift sections of FODO lattice, with bending magnets interspersed in such a way as to provide achromaticity, convenience in energy and emittance definition, and independent tuning of the various optical parameters for matching into the ring. The last 360/degree/ of phase shift has 88 milliradians of bend in a vertical plane and deposits the beam at the injection septum via a Lambertson magnet. Injection is accomplished by launching the beam with several centimeters of radial betatron amplitude in a fast bump provided by a triad of pulsed kicker magnets. Radiation damping reduces the collective amplitude quickly enough to allow injection at a high repetition rate

  9. Injection-induced moment release can also be aseismic

    Science.gov (United States)

    McGarr, Arthur; Barbour, Andrew J.

    2018-01-01

    The cumulative seismic moment is a robust measure of the earthquake response to fluid injection for injection volumes ranging from 3100 to about 12 million m3. Over this range, the moment release is limited to twice the product of the shear modulus and the volume of injected fluid. This relation also applies at the much smaller injection volumes of the field experiment in France reported by Guglielmi, et al. (2015) and laboratory experiments to simulate hydraulic fracturing described by Goodfellow, et al. (2015). In both of these studies, the relevant moment release for comparison with the fluid injection was aseismic and consistent with the scaling that applies to the much larger volumes associated with injection-induced earthquakes with magnitudes extending up to 5.8. Neither the micro-earthquakes, at the site in France, nor the acoustic emission in the laboratory samples contributed significantly to the deformation due to fluid injection.

  10. Injection and Dump Systems

    CERN Document Server

    Bracco, C; Barnes, M J; Carlier, E; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Performance and failures of the LHC injection and ex- traction systems are presented. In particular, a comparison with the 2010 run, lessons learnt during operation with high intensity beams and foreseen upgrades are described. UFOs, vacuum and impedance problems related to the injection and extraction equipment are analysed together with possible improvements and solutions. New implemented features, diagnostics, critical issues of XPOC and IQC applications are addressed.

  11. Simulation of TRAN B experiments by alumina thermite melt injection (SIMBATH out-of-pile experiments, TRAN simulation B1/1, B1/3, B1/4)

    International Nuclear Information System (INIS)

    Peppler, W.; Will, H.

    1986-07-01

    The SIMBATH programme was initiated to investigate the physical phenomena of transient material movement and relocation during transient overpower (TOP) and loss of flow (LOF) driven TOP accidents in LMFBR's. The energy release during the accident is simulated out of pile by the reaction of a thermite mixture. Within the frame of comparing studies of the behaviour of fuel (UO 2 ) and the thermite melt (Al 2 O 3 +Fe) used, respectively, the TRAN B series was reproduced out of pile with this thermite. Special emphasis is given to the similarities and differences in the freezing behaviour of these two materials. The test results of the simulation experiments are analysed and reported. Additionally the tests were recalculated with the code PLUGM. Similarity is found with respect to the freezing behaviour of these two materials. (orig.) [de

  12. TRAC-PF1 code assessment using OECD LOFT LP-FP-1 experiment

    International Nuclear Information System (INIS)

    Barbero, F.J.

    1992-04-01

    This report assesses thermal-hydraulic aspects of LOFT LP-FP-1 experiment making use of TRAC-PF1/MOD1. LP-FP-1 experiment studies the system thermal-hydraulic and core thermal response for initial and boundary conditions similar to a large-break design basis LOCA leading to fission product release from the fuel cladding gap region. It also assesses the fission product retention effectiveness of the PWR-ECCS in best estimate conditions

  13. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  14. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  15. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation

    OpenAIRE

    Karakan, Tolga; Ersoy, Erim; Hasçiçek, Metin; Özgür, Berat Cem; Özcan, Serkan; Aydın, Arif

    2012-01-01

    Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  16. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation.

    Science.gov (United States)

    Karakan, Tolga; Ersoy, Erim; Hasçiçek, Metin; Ozgür, Berat Cem; Ozcan, Serkan; Aydın, Arif

    2012-01-01

    Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  17. Injection of Vaseline under Penis Skin for the Purpose of Penis Augmentation

    Directory of Open Access Journals (Sweden)

    Tolga Karakan

    2012-01-01

    Full Text Available Penile foreign body injection is an uncommon entity produced by penile paraffin, mineral oil, and vaseline injections for the purpose of penile enlargement. Generally, penile subcutaneous and glandular injections for penile augmentation are performed by a nonmedical person, under unacceptable conditions. It will be an aim to share our experiences about penile vaseline injection.

  18. Reactor water injection facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-05-02

    A steam turbine and an electric generator are connected by way of a speed convertor. The speed convertor is controlled so that the number of rotation of the electric generator is constant irrespective of the speed change of the steam turbine. A shaft coupler is disposed between the turbine and the electric generator or between the turbine and a water injection pump. With such a constitution, the steam turbine and the electric generator are connected by way of the speed convertor, and since the number of revolution of the electric generator is controlled to be constant, the change of the number of rotation of the turbine can be controlled irrespective of the change of the number of rotation of the electric generator. Accordingly, the flow rate of the injection water from the water injection pump to a reactor pressure vessel can be controlled freely thereby enabling to supply stable electric power. (T.M.)

  19. COMBUSTION ANALYSIS OF A CNG DIRECT INJECTION SPARK IGNITION ENGINE

    Directory of Open Access Journals (Sweden)

    A. Rashid A. Aziz

    2010-12-01

    Full Text Available An experimental study was carried out on a dedicated compressed natural gas direct injection (CNG-DI engine with a compression ratio (CR of 14 and a central injection system. Several injection timing parameters from early injection timing (300 BTDC to partial direct injection (180 BTDC to full direct injection (120 BTDC were investigated. The 300 BTDC injection timing experiment was carried out to simulate the performance of a port injection engine and the result is used as a benchmark for engine performance. The full DI resulted in a 20% higher performance than the early injection timing for low engine speeds up to 2750 rpm. 180 BTDC injection timing shows the highest performance over an extensive range of engine speed because it has a similar volumetric efficiency to full DI. However, the earlier injection timing allowed for a better air–fuel mixing and gives superior performance for engine speeds above 4500 rpm. The engine performance could be explained by analysis of the heat release rate that shows that at low and intermediate engine speeds of 2000 and 3000, the full DI and partial DI resulted in the fastest heat release rate whereas at a high engine speed of 5000 rpm, the simulated port injection operation resulted in the fastest heat release rate.

  20. Sub-stratum injection of fine tailings

    Energy Technology Data Exchange (ETDEWEB)

    Kesteren van, W.; Cornelisse, J.; Costello, M. [Deltares, Delft (Netherlands)

    2010-07-01

    This PowerPoint presentation discussed an experiment conducted to evaluate the sub-stratum injection of oil sands fine tailings. The hydraulic fracturing method was developed as a sub-surface dredging process for mining sand without removing the overburden. Pressure was used to transport the sand-water mixture, and the high pressures used in the process resulted in water losses through the clay-sand interface. The experiment was conducted with soft clay, compacted sand, and an injection feed. Results of the study showed that the injection method may be successful. However, further research is required to characterize the fracture energy of oil sands and the rheology of fine tailings. Horizontal hydraulic fracturing equations were presented. Tensile failures in clay and oil sands were discussed. Fractures were identified by deformation and discharge rates. Crack propagation methods were also studied. tabs., figs.

  1. A study on the effect of fluidic device installed in a safety injection tank on thermal-hydraulic phenomena of large break loss of coolant accident

    International Nuclear Information System (INIS)

    Chung, Young Jong; Bae, Kyoo Hwan; Song, Jin Ho; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The performance of the Safety Injection Tank (SIT) with fluidic device (advanced SIT) is analyzed for the large break loss of coolant accident (LBLOCA) using RELAP5/MOD3.1-KREM. First the case is analyzed using the conventional SIT. Among various cases the case with 4-split downcomer, discharge coefficient Cd=0.6, MCP trip with reactor trip and break location of cold leg discharge side with the pressurizer is found to be the most limiting case. For the same condition, the advanced SIT results the similar PCT, however it can maintain adequately the liquid level in the downcomer. By changing the ECCS location from the current injection to the cold leg elevations, PCT is improved by 75 K. (Author). 6 refs., 4 tabs., 54 figs

  2. Oxygen injection facility

    International Nuclear Information System (INIS)

    Ota, Masamoto; Hirose, Yuki

    1998-01-01

    A compressor introduces air as a starting material and sends it to a dust removing device, a dehumidifying device and an adsorption/separation system disposed downstream. The facility of the present invention is disposed in the vicinity of an injection point and installed in a turbine building of a BWR type reactor having a pipeline of a feedwater system to be injected. The adsorbing/separation system comprises an adsorbing vessel and an automatic valve, and the adsorbing vessel is filled with an adsorbent for selectively adsorbing nitrogen. Zeolite is used as the adsorbent. Nitrogen in the air passing through the adsorbing vessel is adsorbed and removed under a pressurized condition, and a highly concentrated oxygen gas is formed. The direction of the steam of the adsorbed nitrogen is changed by an opening/closing switching operation of an automatic valve and released to the atmosphere (the pressure is released). Generated oxygen gas is stored under pressure in a tank, and injected to the pipeline of the feedwater system by an oxygen injection conduit by way of a flow rate control valve. In the adsorbing vessel, steps of adsorption, separation and storage under pressure are repeated successively. (I.N.)

  3. Water injection dredging

    NARCIS (Netherlands)

    Verhagen, H.J.

    2000-01-01

    Some twenty years ago WIS-dredging has been developed in the Netherlands. By injecting water into the mud layer, the water content of the mud becomes higher, it becomes fluid mud and will start to flow. The advantages of this system are that there is no need of transporting the mud in a hopper, and

  4. Botulinum Neurotoxin Injections

    Science.gov (United States)

    ... botulinum neurotoxin as much art as it is science. It is in your best interest to locate the most well-trained and experienced doctor you can find. Before making an appointment to receive botulinum neuro toxin injections, ask the office personnel which doctor ...

  5. Piperacillin and Tazobactam Injection

    Science.gov (United States)

    ... is in a class of medications called penicillin antibiotics. It works by killing bacteria that cause infection. Tazobactam is ... It works by preventing bacteria from destroying piperacillin.Antibiotics ... injection will not work for colds, flu, or other viral infections. Taking ...

  6. Meropenem and Vaborbactam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria. Vaborbactam is in a class ... It works by preventing bacteria from destroying meropenem.Antibiotics such as meropenem and vaborbactam injection will not work for colds, flu, or other viral infections. Taking ...

  7. Cold water injection nozzles

    International Nuclear Information System (INIS)

    Kura, Masaaki; Maeda, Masamitsu; Endo, Takio.

    1979-01-01

    Purpose: To inject cold water in a reactor without applying heat cycles to a reactor container and to the inner wall of a feedwater nozzle by securing a perforated plate at the outlet of the cold water injection nozzle. Constitution: A disc-like cap is secured to the final end of a return nozzle of a control rod drive. The cap prevents the flow of a high temperature water flowing downward in the reactor from entering into the nozzle. The cap is perforated with a plurality of bore holes for injecting cold water into the reactor. The cap is made to about 100 mm in thickness so that the cold water passing through the bore holes is heated by the heat conduction in the cap. Accordingly, the flow of high temperature water flowing downwardly in the reactor is inhibited by the cap from backward flowing into the nozzle. Moreover, the flow of the cold water in the nozzle is controlled and rectified when passed through the bore holes in the cap and then injected into the reactor. (Yoshino, Y.)

  8. Magnetron injection gun scaling

    International Nuclear Information System (INIS)

    Lawson, W.

    1988-01-01

    Existing analytic design equations for magnetron injection guns (MIG's) are approximated to obtain a set of scaling laws. The constraints are chosen to examine the maximum peak power capabilities of MIG's. The scaling laws are compared with exact solutions of the design equations and are supported by MIG simulations

  9. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  10. SPS injection kicker magnet

    CERN Document Server

    1975-01-01

    One of the first-generation SPS injection kicker magnets. Lifting the tank-lid reveals the inner structure. For a more detailed description see 7502072X. See also 7502074X and Annual Report 1975, p.162. To the left: Roland Tröhler; to the right: Giacomo Busetta.

  11. Magnetic detection of ferrofluid injection zones

    Energy Technology Data Exchange (ETDEWEB)

    Borglin, S.; Moridis, G.; Becker, A.

    1998-03-01

    Ferrofluids are stable colloidal suspensions of magnetic particles that can be stabilized in various carrier liquids. In this study the authors investigate the potential of ferrofluids to trace the movement and position of liquids injected in the subsurface using geophysical methods. An ability to track and monitor the movement and position of injected liquids is essential in assessing the effectiveness of the delivery system and the success of the process. Ferrofluids can also provide a significant detection and verification tool in containment technologies, where they can be injected with the barrier liquids to provide a strong signature allowing determination of the barrier geometry, extent, continuity and integrity. Finally, ferrofluids may have unique properties as tracers for detecting preferential flow features (such as fractures) in the subsurface, and thus allow the design of more effective remediation systems. In this report the authors review the results of the investigation of the potential of ferrofluids to trace the movement and position of liquids injected in the subsurface using geophysical methods. They demonstrate the feasibility of using conventional magnetometry for detecting subsurface zones of injected ferrofluids used to trace liquids injected for remediation or barrier formation. The geometrical shapes considered were a sphere, a thin disk, a rectangular horizontal slab, and a cylinder. Simple calculations based on the principles of magnetometry are made to determine the detection depths of FTs. Experiments involving spherical, cylindrical and horizontal slabs show a very good agreement between predictions and measurements.

  12. Alternative energy sources: ECC report

    International Nuclear Information System (INIS)

    Renwick, Lord; Stoddart, Lord; Lauderdale, Earl of

    1988-01-01

    The European Communities Committee Report on Alternative Energy Resources was debated. Six alternative energy sources were first described - wind power, biomass, geothermal energy, solar energy, wave and tidal power. Combined heat and power was also mentioned. General questions concerning alternative energy sources were then considered. In particular, their potential contribution to the energy demand was assessed. The evidence presented to the committee suggested that they would only make a small contribution in the near future and could not be considered as a substitute for coal and nuclear power. However, by the year 2030 it would be possible for 18% of the national electricity demand to be met by alternative energy sources. The economic and environmental issues were assessed briefly and the report's conclusions were summarized. An independent review of wave power was called for in view of conflicting evidence presented to the committee. The debate which followed lasted three hours and is reported verbatim. Other issues raised included energy conservation, public attitudes to energy, the environment, government and private funding of research and development of nuclear power, including fusion. (U.K.)

  13. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  14. Effects of upper plenum injection on thermo-hydrodynamic behavior under refill and reflood phases

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Abe, Yutaka; Adachi, Hiromichi; Ohnuki, Akira; Osakabe, Masahiro

    1984-12-01

    In order to investigate the thermo-hydrodynamic behavior in core under simultaneous ECC water injection into the upper plenum and the intact cold leg during the refill and reflood phases of a PWR-LOCA, Tests S1-SH3 and S1-SH4 were performed by using Slab Core Test Facility (SCTF) with the injection of saturated and 67K subcooled water into the upper plenum, respectively, under the same cold leg injection condition. The following major findings were obtained by examining these test results. (1) Although the core was cooled by the fall back water from the upper plenum into the core during the period of high injection rate into the upper plenum, the core was cooled mainly by the bottom flooding after the BOCREC (Bottom of core recovery). (2) The possible fall back flow rate estimated with a CCFL correlation rapidly decreased after the BOCREC because of the increase of steam generation rate in core. (3) Continuous fall back of subcooled water was not observed even under the condition with large upper plenum injection rate of subcooled water and with steam outflow through the lower plenum into the downcomer. The fall back was intermittently limited by the rapid increase of upward steam flow which was generated in the core due to the evaporation of the fall back water. (4) The rising of liquid level in the lower plenum was suppressed by the pressurization in core due to the evaporation of fall back water before the BOCREC and therefore the beginning of bottom reflood was delayed. Some selected data from Tests S1-SH3 and S1-SH4 are also included in this report. (author)

  15. Two-phase CFD PTS validation in an extended range of thermohydraulics conditions covered by the COSI experiment

    International Nuclear Information System (INIS)

    Coste, P.; Ortolan, A.

    2014-01-01

    Highlights: • Models for large interfaces in two-phase CFD were developed for PTS. • The COSI experiment is used for NEPTUNE C FD integral validation. • COSI is a PWR cold leg scaled 1/100 for volume. • Fifty runs are calculated, covering a large range of flow configurations. • The CFD predicting capability is analysed using global and local measurements. - Abstract: In the context of the Pressurized Water Reactors (PWR) life duration safety studies, some models were developed to address the Pressurized Thermal Shock (PTS) from the two-phase CFD angle, dealing with interfaces much larger than cells size and with direct contact condensation. Such models were implemented in NEPTUNE C FD, a 3D transient Eulerian two-fluid model. The COSI experiment is used for its integral validation. It represents a cold leg scaled 1/100 for volume and power from a 900 MW PWR under a large range of LOCA PTS conditions. In this study, the CFD is evaluated in the whole range of parameters and flow configurations covered by the experiment. In a first step, a single choice of mesh and CFD models parameters is fixed and justified. In a second step, fifty runs are calculated. The CFD predicting capability is analysed, comparing the liquid temperature and the total condensation rate with the experiment, discussing their dependency on the inlet cold liquid rate, on the liquid level in the cold leg and on the difference between co-current and counter-current runs. It is shown that NEPTUNE C FD 1.0.8 calculates with a fair agreement a large range of flow configurations related to ECCS injection and steam condensation

  16. Gas injection in EBT-S for assessment of particle loading effects of neutral beam injection

    International Nuclear Information System (INIS)

    Carpenter, K.H.; Glowienka, J.C.

    1979-01-01

    Experiments have begun to examine the physics of neutral beam injection on EBT-S. Preliminary experiments have been limited to a calibrated gas puffing experiment which simulates the effects of a pulsed beam with zero energy. These experiments begin to address some of the compatibility problems that exist for future beam heating experiments on EBT devices. In particular, neutral beams are to be a significant part of the planned EBT-II experiment which is designed to demonstrate steady-state, reactor-like conditions with both electron cyclotron heating and neutral beam heating

  17. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  18. Neutral beam injection on the PLT tokamak

    International Nuclear Information System (INIS)

    Schilling, G.; Ashcroft, D.L.; Eubank, H.P.; Grisham, L.R.; Knauer, R.C.; Stewart, L.D.; Stooksberry, R.W.; Ulrickson, M.; Williams, M.D.

    1981-01-01

    We describe the operation of the neutral beam injection system on the PLT tokamak. Improvements, retrofits, and conditioning have changed the injection system from an experiment in itself to a fairly reliable and useful plasma heating tool. We will present a brief overview of our physics achievements and then describe the system as it exists now. This will include injector performance, conditioning needs, maintenance needs, reliability, and daily operating sequences. We will also include hardware modifications and additions, electrical and mechanical, and point out remaining problem areas

  19. Injection envelope matching in storage rings

    International Nuclear Information System (INIS)

    Minty, M.G.; Spence, W.L.

    1995-05-01

    The shape and size of the transverse phase space injected into a storage ring can be deduced from turn-by-turn measurements of the transient behavior of the beam envelope in the ring. Envelope oscillations at 2 x the β-tron frequency indicate the presence of a β-mismatch, while envelope oscillations at the β-tron frequency are the signature of a dispersion function mismatch. Experiments in injection optimization using synchrotron radiation imaging of the beam and a fast-gated camera at the SLC damping rings are reported

  20. Neutral beam injection in 2XIIB

    International Nuclear Information System (INIS)

    Hibbs, S.M.

    1975-01-01

    Integrated into the operation of the 2XIIB controlled fusion experiment is a 600-A, 20-keV neutral injection system: the highest neutral-beam current capacity of any existing fusion machine. This paper outlines the requirements of the injection system and the design features to which they led. Both mechanical and electrical aspects are discussed. Also included is a brief description of some operational aspects of the system and some of the things we have learned along the way, as well as a short history of the most significant developments