WorldWideScience

Sample records for ear surgery simulator

  1. Cosmetic ear surgery

    Science.gov (United States)

    Otoplasty; Ear pinning; Ear surgery - cosmetic; Ear reshaping; Pinnaplasty ... Cosmetic ear surgery may be done in the surgeon's office, an outpatient clinic, or a hospital. It can be performed under ...

  2. 3D-printed pediatric endoscopic ear surgery simulator for surgical training.

    Science.gov (United States)

    Barber, Samuel R; Kozin, Elliott D; Dedmon, Matthew; Lin, Brian M; Lee, Kyuwon; Sinha, Sumi; Black, Nicole; Remenschneider, Aaron K; Lee, Daniel J

    2016-11-01

    Surgical simulators are designed to improve operative skills and patient safety. Transcanal Endoscopic Ear Surgery (TEES) is a relatively new surgical approach with a slow learning curve due to one-handed dissection. A reusable and customizable 3-dimensional (3D)-printed endoscopic ear surgery simulator may facilitate the development of surgical skills with high fidelity and low cost. Herein, we aim to design, fabricate, and test a low-cost and reusable 3D-printed TEES simulator. The TEES simulator was designed in computer-aided design (CAD) software using anatomic measurements taken from anthropometric studies. Cross sections from external auditory canal samples were traced as vectors and serially combined into a mesh construct. A modified tympanic cavity with a modular testing platform for simulator tasks was incorporated. Components were fabricated using calcium sulfate hemihydrate powder and multiple colored infiltrants via a commercial inkjet 3D-printing service. All components of a left-sided ear were printed to scale. Six right-handed trainees completed three trials each. Mean trial time (n = 3) ranged from 23.03 to 62.77 s using the dominant hand for all dissection. Statistically significant differences between first and last completion time with the dominant hand (p 3D-printed simulator is feasible for TEES simulation. Otolaryngology training programs with access to a 3D printer may readily fabricate a TEES simulator, resulting in inexpensive yet high-fidelity surgical simulation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. The visible ear simulator: a public PC application for GPU-accelerated haptic 3D simulation of ear surgery based on the visible ear data

    DEFF Research Database (Denmark)

    Sørensen, Mads Sølvsten; Mosegaard, Jesper; Trier, Peter

    2009-01-01

    material.Virtual training often requires the purchase of a program, a customized computer, and expensive peripherals dedicated exclusively to this purpose. MATERIALS AND METHODS: The Visible Ear freeware library of digital images from a fresh-frozen human temporal bone was segmented, and real-time volume...... is published for download (approximately 120 MB) as freeware at http://www.alexandra.dk/ves/index.htm.With increasing personal computer performance, future versions may include enhanced resolution (up to 8,000 voxels/mm3) and realistic interaction with deformable soft tissue components such as skin, tympanic...

  4. Ear tube surgery - what to ask your doctor

    Science.gov (United States)

    What to ask your doctor about ear tube surgery; Tympanostomy - what to ask your doctor; Myringotomy - what ... other treatments? What are the risks of the surgery? Is it safe to wait before getting ear ...

  5. A break-even analysis of major ear surgery.

    Science.gov (United States)

    Wasson, J D; Phillips, J S

    2015-10-01

    To determine variables which affect cost and profit for major ear surgery and perform a break-even analysis. Retrospective financial analysis. UK teaching hospital. Patients who underwent major ear surgery under general anaesthesia performed by the senior author in main theatre over a 2-year period between dates of 07 September 2010 and 07 September 2012. Income, cost and profit for each major ear patient spell. Variables that affect major ear surgery profitability. Seventy-six patients met inclusion criteria. Wide variation in earnings, with a median net loss of £-1345.50 was observed. Income was relatively uniform across all patient spells; however, theatre time of major ear surgery at a cost of £953.24 per hour varied between patients and was the main determinant of cost and profit for the patient spell. Bivariate linear regression of earnings on theatre time identified 94% of variation in earnings was due to variation in theatre time (r = -0.969; P break-even time for major ear surgery of 110.6 min. Theatre time was dependent on complexity of procedure and number of OPCS4 procedures performed, with a significant increase in theatre time when three or more procedures were performed during major ear surgery (P = 0.015). For major ear surgery to either break-even or return a profit, total theatre time should not exceed 110 min and 36 s. © 2015 John Wiley & Sons Ltd.

  6. Direct cost comparison of totally endoscopic versus open ear surgery.

    Science.gov (United States)

    Patel, N; Mohammadi, A; Jufas, N

    2018-02-01

    Totally endoscopic ear surgery is a relatively new method for managing chronic ear disease. This study aimed to test the null hypothesis that open and endoscopic approaches have similar direct costs for the management of attic cholesteatoma, from an Australian private hospital setting. A retrospective direct cost comparison of totally endoscopic ear surgery and traditional canal wall up mastoidectomy for the management of attic cholesteatoma in a private tertiary setting was undertaken. Indirect and future costs were excluded. A direct cost comparison of anaesthetic setup and resources, operative setup and resources, and surgical time was performed between the two techniques. Totally endoscopic ear surgery has a mean direct cost reduction of AUD$2978.89 per operation from the hospital perspective, when compared to canal wall up mastoidectomy. Totally endoscopic ear surgery is more cost-effective, from an Australian private hospital perspective, than canal wall up mastoidectomy for attic cholesteatoma.

  7. Early and late surgical site infections in ear surgery.

    Science.gov (United States)

    Bastier, P L; Leroyer, C; Lashéras, A; Rogues, A-M; Darrouzet, V; Franco-Vidal, V

    2016-04-01

    A retroauricular approach is routinely used for treating chronic otitis media. The incidence of surgical site infections after ear surgery is around 10% in contaminated or dirty procedures. This observational prospective study describes surgical site infections after chronic otitis media surgery with the retroauricular approach and investigated their potential predictive factors. This observational prospective study included patients suffering from chronic otitis media and eligible for therapeutic surgery with a retroauricular approach. During follow-up, surgical site infections were defined as "early" if occurring within 30 days after surgery or as "late" if occurring thereafter. The data of 102 patients were analysed. Concerning early surgical site infections, four cases were diagnosed (3.9%) and a significant association was found with preoperative antibiotic therapy, wet ear at pre-operative examination, class III (contaminated) in the surgical wound classification, NNIS (National Nosocomial Infection Surveillance) index > 1, and oral post-operative antibiotic use. Seven late surgical site infections were diagnosed (7.1%) between 90 and 160 days after surgery and were significantly correlated to otorrhoea during the 6 months before surgery, surgery duration ≤60 minutes, canal wall down technique and use of fibrin glue. Surgical site infections after chronic otitis media surgery seem to be associated with factors related to the inflammatory state of the middle ear at the time of surgery in early infections and with chronic inflammation in late infections. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  8. Ear surgery techniques results on hearing threshold improvement

    Directory of Open Access Journals (Sweden)

    Farhad Mokhtarinejad

    2013-01-01

    Full Text Available Background: Bone conduction (BC threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. Materials and Methods: This study was conducted as a clinical trial study. The ear surgery performed on 83 patients classified in four categories: Stapedectomy, tympanomastoid surgery and ossicular reconstruction partially or totally; Partial Ossicular Replacement Prosthesis (PORP and Total Ossicular Replacement Prosthesis (TORP. Bone conduction thresholds assessed in frequencies of 250, 500, 1000, 2000 and 4000 Hz pre and post the surgery. Results: In stapedectomy group, the average of BC threshold in all frequencies improved approximately 6 dB in frequency of 2000 Hz. In tympanomastoid group, BC threshold in the frequency of 500, 1000 and 2000 Hz changed 4 dB (P-value < 0.05. Moreover, In the PORP group, 5 dB enhancement was seen in 1000 and 2000 Hz. In TORP group, the results confirmed that BC threshold improved in all frequencies especially at 4000 Hz about 6.5 dB. Conclusion: In according to results of this study, BC threshold shift was seen after several ear surgeries such as stapedectomy, tympanoplasty, PORP and TORP. The average of BC improvement was approximately 5 dB. It must be considered that BC depression might happen because of ossicular chain problems. Therefore; by resolving middle ear pathologies, the better BC threshold was obtained, the less hearing problems would be faced.

  9. Laser surgery in ear, nose and throat

    International Nuclear Information System (INIS)

    Winter, F.Oe.; Teig, E.; Haye, R.

    1991-01-01

    This survey is based on own experiences and a study of the literature. The CO 2 laser has certain advantages in the surgical treatment of otosclerosis, both in the primary operation and in reoperation. In rhinal surgery the argon laser has been used with good results in Osler's disease. Laser surgery is not recommended for vasomotoric rhinitis and polyposis. The CO-2 laser has improved the quality of treatment of laryngeal papilloma. With high precision and minimal bleeding the postoperative voice is better than with conventional surgery. The CO 2 laser can also be used to exstirpate small malignant tumours of the tongue and leukoplasia of the oral mucosa. Healing is rapid and involves relatively little pain. The postoperative functional results is usually good, due to moderate formation of scars. 11 refs., 2 tabs

  10. Intra-operative hearing monitoring methods in middle ear surgeries

    Directory of Open Access Journals (Sweden)

    Wei Ren

    2016-12-01

    Full Text Available Hearing loss is a condition affecting millions of people worldwide. Conductive hearing loss (CHL is mainly caused by middle ear diseases. The low frequency area is the pivotal part of speech frequencies and most frequently impaired in patients with CHL. Among various treatments of CHL, middle ear surgery is efficient to improve hearing. However, variable success rates and possible needs for prolonged revision surgery still frustrate both surgeons and patients. Nowadays, increasing numbers of researchers explore various methods to monitor the efficacy of ossicular reconstruction intraoperatively, including electrocochleography (ECochG, auditory brainstem response (ABR, auditory steady state response (ASSR, distortion product otoacoustic emissions (DPOAE, subjective whisper test, and optical coherence tomography (OCT. Here, we illustrate several methods used clinically by reviewing the literature.

  11. Middle-Ear Microsurgery Simulation to Improve New Robotic Procedures

    Directory of Open Access Journals (Sweden)

    Guillaume Kazmitcheff

    2014-01-01

    Full Text Available Otological microsurgery is delicate and requires high dexterity in bad ergonomic conditions. To assist surgeons in these indications, a teleoperated system, called RobOtol, is developed. This robot enhances gesture accuracy and handiness and allows exploration of new procedures for middle ear surgery. To plan new procedures that exploit the capacities given by the robot, a surgical simulator is developed. The simulation reproduces with high fidelity the behavior of the anatomical structures and can also be used as a training tool for an easier control of the robot for surgeons. In the paper, we introduce the middle ear surgical simulation and then we perform virtually two challenging procedures with the robot. We show how interactive simulation can assist in analyzing the benefits of robotics in the case of complex manipulations or ergonomics studies and allow the development of innovative surgical procedures. New robot-based microsurgical procedures are investigated. The improvement offered by RobOtol is also evaluated and discussed.

  12. CT and MR imaging after middle ear surgery

    International Nuclear Information System (INIS)

    Koesling, Sabrina; Bootz, F.

    2001-01-01

    This article describes the current value of imaging in patients after stapes surgery and surgery after chronic otitis media including cholesteatoma. Possibilities and limits of computed tomography (CT) and MRI are described and most important investigation parameters are mentioned. After otosclerosis surgery, CT is the method of first choice in detection of reasons for vertigo and/or recurrent hearing loss in the later postoperative phase. CT may show the position and condition of prosthesis, scarring around the prosthesis and otospongiotic foci. Sometimes, it gives indirect hints for perilymphatic fistulas and incus necrosis. MRI is able to document inner ear complications. CT has a high negative predictive value in cases with a free cavity after mastoidectomy. Localized opacities or total occlusion are difficult to distinguish by CT alone. MRI provides important additional information in the differentiation of cholesterol granuloma, cholesteatoma, effusion, granulation and scar tissue

  13. CT and MR imaging after middle ear surgery

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, Sabrina E-mail: sabrina.koesling@medizin.uni-halle.de; Bootz, F

    2001-11-01

    This article describes the current value of imaging in patients after stapes surgery and surgery after chronic otitis media including cholesteatoma. Possibilities and limits of computed tomography (CT) and MRI are described and most important investigation parameters are mentioned. After otosclerosis surgery, CT is the method of first choice in detection of reasons for vertigo and/or recurrent hearing loss in the later postoperative phase. CT may show the position and condition of prosthesis, scarring around the prosthesis and otospongiotic foci. Sometimes, it gives indirect hints for perilymphatic fistulas and incus necrosis. MRI is able to document inner ear complications. CT has a high negative predictive value in cases with a free cavity after mastoidectomy. Localized opacities or total occlusion are difficult to distinguish by CT alone. MRI provides important additional information in the differentiation of cholesterol granuloma, cholesteatoma, effusion, granulation and scar tissue.

  14. [Simulation in pediatric surgery].

    Science.gov (United States)

    Becmeur, François; Lacreuse, Isabelle; Soler, Luc

    2011-11-01

    Simulation in paediatric surgery is essential for educational, ethical, medicolegal and economic reasons, and is particularly important for rare procedures. There are three different levels of simulation:--simulation of basic techniques in order to learn or improve surgical skills (dissection, intracorporeal knots, etc.);--preparation for surgery using virtual reality, to perfect and test various procedures on a virtual patient, and to determine the best approaches for individual cases;--behavioral simulation underlines the importance of the preoperative check-list and facilitates crisis management (complications, conversion, etc.).

  15. [Surgical manipulators in ear surgery: a future vision?].

    Science.gov (United States)

    Hofer, M; Dietz, A; Strauss, G

    2011-04-01

    Middle ear surgery bears a high risk for injury of difficult to differentiate risk structures. Thus, a precise preparation in this area must be the surgical task. However, there are human (tremor) and systematic limitations (OR setup, narrow access). Assistance systems in terms of manipulators are so far not part of the clinical routine. Although, they could compensate for the above mentioned limitations. MANIPULATORS: This work reviews existing surgical manipulator systems. The expected value is an elevated patient safety through improving surgical accuracy and the reduction of ergonomic deficits. CLINICAL APPLICATION AND DEVELOPMENT: In clinical application there are simply modified industrial robots, highly complex master slave systems and small miniature master slave systems which are directly located at the patient. A disadvantage of most systems is the limited number of applicable instruments. Often, only especially designed instruments can be used. The goal in development should be to create a compact, short distance operated master slave system. The usability of standard (already available) instruments with an easy integration into the surgical and sterilisation procedure would lower the threshold for acceptance of such systems.The surgeon will remain the key player. He can only work efficiently in an ergonomic environment and will always have the responsibility for the intervention. From the authors perspective, highly automated systems should not be the research goal. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Manual accuracy in comparison with a miniature master slave device--preclinical evaluation for ear surgery.

    Science.gov (United States)

    Runge, A; Hofer, M; Dittrich, E; Neumuth, T; Haase, R; Strauss, M; Dietz, A; Lüth, T; Strauss, G

    2011-01-01

    Manual accuracy in microsurgery is reduced by tremor and limited access. A surgical approach through the middle ear also puts delicate structures at risk, while the surgeon is often working at an unergonomic position. At this point a micromanipulator could have a positive influence. A system was developed to measure "working accuracy", time and precision during manipulation in the middle ear. 10 ENT-surgeons simulated a perforation of the stapedial footplate on a modified 3D print of a human skull in a mock OR. Each trial was repeated more than 200 times aiming manually and using a micro-manipulator. Data of over 4000 measurements was tested and graphically processed. Work strain was evaluated with a questionnaire. Accuracy for manual and micromanipulator perforation revealed a small difference. Learning curves showed a stronger decrease both in deviation and time when the micromanipulator was used. Also a lower work strain was apparent. The micromanipulator has the potential as an aiding device in ear surgery.

  17. Mobile, one stage, bilateral ear surgery for chronic otitis media patients in remote areas

    DEFF Research Database (Denmark)

    Homøe, P; Sørensen, H C Florian; Tos, M

    2009-01-01

    OBJECTIVES: We evaluated the results of mobile, one stage, bilateral ear surgery conducted in Greenland, where chronic otitis media with and without suppuration is prevalent. The study aimed to increase the number of operations conducted and to reduce the cost of ear surgery in remote areas....... MATERIALS AND METHODS: The study was longitudinal and prospective, with a two-year follow up. Seventeen East Greenlandic patients with bilateral chronic suppurative otitis media or chronic otitis media were selected. Their median age was 16 years; 53 per cent were female and 47 per cent male. Hearing...... were satisfied. There were no hearing hazards. CONCLUSIONS: The results of mobile, one stage, bilateral ear surgery conducted in Greenland for long-lasting chronic suppurative otitis media and chronic otitis media were acceptable and safe, and more ears underwent surgery at reduced cost compared...

  18. Endoscopic and minimally-invasive ear surgery: A path to better outcomes

    Directory of Open Access Journals (Sweden)

    Natasha Pollak

    2017-09-01

    Full Text Available The development of endoscopic ear surgery techniques promises to change the way we approach ear surgery. In this review paper, we explore the current evidence, seek to determine the advantages of endoscopic ear surgery, and see if these advantages are both measureable and meaningful. The wide field of view of the endoscope allows the surgeon to better visualize the various recesses of the middle ear cleft. Endoscopes make it possible to address the target pathology transcanal, while minimizing dissection or normal tissue done purely for exposure, leading to the evolution of minimally-invasive ear surgery and reducing morbidity. When used in chronic ear surgery, endoscopy appears to have the potential to significantly reduce cholesteatoma recidivism rates. Using endoscopes as an adjunct can increase the surgeon's confidence in total cholesteatoma removal. By doing so, endoscopes reduce the need to reopen the mastoid during second-look surgery, help preserve the canal wall, or even change post-cholesteatoma follow-up protocols by channeling more patients away from a planned second-look.

  19. YouTube as an information source for pediatric adenotonsillectomy and ear tube surgery.

    Science.gov (United States)

    Sorensen, Jeffrey A; Pusz, Max D; Brietzke, Scott E

    2014-01-01

    Assess the overall quality of information on adenotonsillectomy and ear tube surgery presented on YouTube (www.youtube.com) from the perspective of a parent or patient searching for information on surgery. The YouTube website was systematically searched on select dates with a formal search strategy to identify videos pertaining to pediatric adenotonsillectomy and ear tube surgery. Only videos with at least 5 (ear tube surgery) or 10 (adenotonsillectomy) views per day were included. Each video was viewed and scored by two independent scorers. Videos were categorized by goal and scored for video/audio quality, accuracy, comprehensiveness, and procedure-specific content. Cross-sectional study. Public domain website. Fifty-five videos were scored for adenotonsillectomy and forty-seven for ear tube surgery. The most common category was educational (65.3%) followed by testimonial (28.4%), and news program (9.8%). Testimonials were more common for adenotonsillectomy than ear tube surgery (41.8% vs. 12.8%, p=0.001). Testimonials had a significantly lower mean accuracy (2.23 vs. 2.62, p=0.02), comprehensiveness (1.71 vs. 2.22, p=0.007), and TA specific content (0.64 vs. 1.69, p=0.001) score than educational type videos. Only six videos (5.9%) received high scores in both video/audio quality and accuracy/comprehensiveness of content. There was no significant association between the accuracy and comprehensive score and views, posted "likes", posted "dislikes", and likes/dislikes ratio. There was an association between "likes" and mean video quality (Spearman's rho=0.262, p=0.008). Parents/patients searching YouTube for information on pediatric adenotonsillectomy and ear tube surgery will generally encounter low quality information with testimonials being common but of significantly lower quality. Viewer perceived quality ("likes") did not correlate to formally scored content quality. Published by Elsevier Ireland Ltd.

  20. The "pixie" ear deformity following face lift surgery revisited.

    Science.gov (United States)

    Mowlavi, Arian; Meldrum, D Garth; Wilhelmi, Bradon J; Russell, Robert C; Zook, Elvin G

    2005-04-01

    The "pixie" ear deformity can be recognized by its "stuck on" or "pulled" appearance, which is caused by the extrinsic pull of the medial cheek and jawline skin flaps at the earlobe attachment point, the otobasion inferius. The tension results in migration of the otobasion inferius from a posterior cephalad position to an anterior caudal position. Although this deformity has been described clinically, it has yet to be objectively defined. Recently, the two components of the earlobe, the attached cephalic segment (intertragal to otobasion inferius distance) and the free caudal segment (otobasion inferius to subaurale distance), were shown to be essential in evaluating for earlobe ptosis and pseudoptosis. These two components can be used to designate an objective criterion for the pixie ear deformity. The deformity, as defined by the authors' parameters, was assessed in 44 patients who had undergone rhytidectomy. A simple and accurate surgical treatment is demonstrated by a cadaver dissection and a clinical case. The deformity can be defined as an increase in the attached cephalic segment (intertragal to otobasion inferius distance) and a decrease in the free caudal segment (otobasion inferius to subaurale distance) to 0 mm following rhytidectomy. The incidence of pixie ear deformity was 5.7 percent in the authors' series of patients. A medially based triangular excision over the attached cephalic segment is presented as a simple and accurate surgical treatment of pixie ear deformity. A more accurate and objective designation may allow for improved detection, avoidance, and treatment of this deformity.

  1. Prevention and management of vascular complications in middle ear and cochlear implant surgery.

    Science.gov (United States)

    Di Lella, Filippo; Falcioni, Maurizio; Piccinini, Silvia; Iaccarino, Ilaria; Bacciu, Andrea; Pasanisi, Enrico; Cerasti, Davide; Vincenti, Vincenzo

    2017-11-01

    The objective of this study is to illustrate prevention strategies and management of vascular complications from the jugular bulb (JB) and internal carotid artery (ICA) during middle ear surgery or cochlear implantation. The study design is retrospective case series. The setting is tertiary referral university hospital. Patients were included if presented pre- or intraoperative evidence of high-risk anatomical anomalies of ICA or JB during middle ear or cochlear implant surgery, intraoperative vascular injury, or revision surgery after the previous iatrogenic vascular lesions. The main outcome measures are surgical outcomes and complications rate. Ten subjects were identified: three underwent cochlear implant surgery and seven underwent middle ear surgery. Among the cochlear implant patients, two presented with anomalies of the JB impeding access to the cochlear lumen and one underwent revision surgery for incorrect positioning of the array in the carotid canal. Subtotal petrosectomy was performed in all cases. Anomalies of the JB were preoperatively identified in two patients with attic and external auditory canal cholesteatoma, respectively. In a patient, a high and dehiscent JB was found during myringoplasty, while another underwent revision surgery after iatrogenic injury of the JB. A dehiscent ICA complicated middle ear effusion in one case, while in another case, a carotid aneurysm determined a cholesterol granuloma. Rupture of a pseudoaneurysm of the ICA occurred in a child during second-stage surgery and required permanent balloon occlusion without neurological complications. Knowledge of normal anatomy and its variants and preoperative imaging are the basis for prevention of vascular complications during middle ear or cochlear implant surgery.

  2. Study the Effect of Nasal Obstruction Surgery (Septoplasty on Eustachian Tube Function and Middle Ear Pressure

    Directory of Open Access Journals (Sweden)

    Rahim Davari

    2014-12-01

    Full Text Available Background & objectives: Deviation of the nasal septum is a common cause of unilateral or bilateral nasal airway obstruction and may follow nasal and midface trauma. Patient complaints of airway obstruction that are consistent with intranasal physical findings often lead to septoplasty and turbinate surgery. Severe nasal septal deviation leads to complete nasal obstruction and disturbs air passage from nostrils, however the effect of septal deviation and nasal obstruction surgery (septoplasty on Eustachian tube function and middle ear pressure is controversial and isn’t clear. Whereas many of surgeons do not believe the considerable effect of septoplasty on Eustachian tube function and middle ear pressure, so they do not recommend this procedure before middle ear surgery. On the other hand, some have an idea that septoplasty has significant effect on middle ear pressure suggesting this procedure before ear surgery like tympanoplasty.   Methods: This prospective analytical-descriptive study was conducted on seventy patients from 18 to 65 years of age who underwent septoplasty due to severe septal deviation leading to nasal obstruction in Beesat Hospital during one year (2012-2013. Middle ear pressure and Eustachian tube function on the septal deviated side and contralateral side before and after septoplasty (3 to 6 months later were measured through tympanometry and Eustachian tube function test (Toynbee test. The comparison between pre- and postoperative ETF tests and middle ear pressures was assessed using Paired –T test and p-value of less than 0.05 was considered as statistically significant.   Results : This study revealed that comparison between mean values of pressure in the deviated and contralateral side has no significant statistical difference before and after septoplasty. Also comparison between Eustachian function in the deviated side and contralateral side showed no significant difference before and after septoplasty.

  3. Assessment of skills using a virtual reality temporal bone surgery simulator.

    Science.gov (United States)

    Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E

    2013-08-01

    Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.

  4. Magnetic resonance imaging of the ear for patient-specific reconstructive surgery.

    Directory of Open Access Journals (Sweden)

    Luc Nimeskern

    Full Text Available INTRODUCTION: Like a fingerprint, ear shape is a unique personal feature that should be reconstructed with a high fidelity during reconstructive surgery. Ear cartilage tissue engineering (TE advantageously offers the possibility to use novel 3D manufacturing techniques to reconstruct the ear, thus allowing for a detailed auricular shape. However it also requires detailed patient-specific images of the 3D cartilage structures of the patient's intact contralateral ear (if available. Therefore the aim of this study was to develop and evaluate an imaging strategy for acquiring patient-specific ear cartilage shape, with sufficient precision and accuracy for use in a clinical setting. METHODS AND MATERIALS: Magnetic resonance imaging (MRI was performed on 14 volunteer and six cadaveric auricles and manually segmented. Reproducibility of cartilage volume (Cg.V, surface (Cg.S and thickness (Cg.Th was assessed, to determine whether raters could repeatedly define the same volume of interest. Additionally, six cadaveric auricles were harvested, scanned and segmented using the same procedure, then dissected and scanned using high resolution micro-CT. Correlation between MR and micro-CT measurements was assessed to determine accuracy. RESULTS: Good inter- and intra-rater reproducibility was observed (precision errors 0.82, but low for Cg.Th (0.95 demonstrated high accuracy. DISCUSSION AND CONCLUSION: This study demonstrated that precision and accuracy of the proposed method was high enough to detect patient-specific variation in ear cartilage geometry. The present study provides a clinical strategy to access the necessary information required for the production of 3D ear scaffolds for TE purposes, including detailed patient-specific shape. Furthermore, the protocol is applicable in daily clinical practice with existing infrastructure.

  5. Ear Acupuncture for Post-Operative Pain Associated with Ambulatory Arthroscopic Knee Surgery: A Randomized Controlled Trial

    Science.gov (United States)

    2014-01-14

    E7(/(3+21(180%(5 ,QFOXGHDUHDFRGH 14 Jan 2014 Final Report Ear acupuncture for post-operative pain associated with ambulatory arthroscopic...DISTRIBUTION A. Approved for public release: distribution unlimited. The purpose of this study is to compare ear acupuncture plus standard therapy versus...3298 Ear Acupuncture for Post-operative Pa111 Assoc1ated With Ambulatory Arthroscopic Knee Surgery A Randomized Controlled Trial ’• V ’’ ’-’ I

  6. Prophylactic antiemetic effects of midazolam, dexamethasone, and its combination after middle ear surgery

    International Nuclear Information System (INIS)

    Makhdoom, Naeem K; Farid, Magdy F

    2009-01-01

    To evaluate and compare the efficacy of the combination of midazolam and dexamethasone, with midazolam and dexamethasone alone, for the prevention of postoperative nausea and vomiting (PONV) in female patients undergoing middle ear surgery. A prospective, randomized, double-blind, placebo-controlled study in 80 female patients (mean age 32.6 years), undergoing middle ear surgery with general anesthesia at Ohud Hospital, Madina, Kingdom of Saudi Arabia from May 2007 to May 2008. Patients were classified into 4 groups. They received intravenous normal saline (S group), midazolam 0.075 mg/kg (M group), or dexamethasone 10 mg (D group), or a combination of midazolam and dexamethasone (MD group), before the induction of anesthesia. Postoperatively for 24 hours observation and assessment of nausea, vomiting, rescue anti-emetics, and side effects of the study drugs such as headache and drowsiness were carried out. There was a significant difference between the 4 groups. The MD group was the least to develop PONV compared to other groups (p<0.01). Regarding nausea, there was a non-significant difference between the 4 groups, although the MD group developed the least symptoms among the 4 groups, there were no significant differences in pain intensity and side effects such as, headache, dizziness, and drowsiness between the 4 groups. The combination of midazolam 0.075 mg/kg and dexamethasone 10 mg intravenously is better than either drug alone in reducing the incidence of PONV in female patients after middle ear surgery. (author)

  7. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    Science.gov (United States)

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  8. Simulation in shoulder surgery.

    Science.gov (United States)

    Colaço, Henry B; Tennent, Duncan

    2016-10-01

    Simulation is a rapidly developing field in medical education. There is a growing need for trainee surgeons to acquire surgical skills in a cost-effective learning environment to improve patient safety and compensate for a reduction in training time and operative experience. Although simulation is not a replacement for traditional models of surgical training, and robust assessment metrics need to be validated before widespread use for accreditation, it is a useful adjunct that may ultimately lead to improving surgical outcomes for our patients.

  9. Ultrasound-guided greater auricular nerve block as sole anesthetic for ear surgery

    Directory of Open Access Journals (Sweden)

    Michael K. Ritchie

    2016-05-01

    Full Text Available A greater auricular nerve (GAN block was used as the sole anesthetic for facial surgery in an 80-year-old male patient with multiple comorbidities which would have made general anesthesia challenging. The GAN provides sensation to the ear, mastoid process, parotid gland, and angle of the mandible. In addition to anesthesia for operating room surgery, the GAN block can be used for outpatient or emergency department procedures without the need for a separate anesthesia team. Although this nerve block has been performed using landmark-based techniques, the ultrasoundguided version offers several potential advantages. These advantages include increased reliability of the nerve block, as well as prevention of inadvertent vascular puncture or blockade of the phrenic nerve, brachial plexus, or deep cervical plexus. The increasing access to ultrasound technology for medical care providers outside the operating room makes this ultrasound guided block an increasingly viable alternative.

  10. [Suture simulator - Cleft palate surgery].

    Science.gov (United States)

    Devinck, F; Riot, S; Qassemyar, A; Belkhou, A; Wolber, A; Martinot Duquennoy, V; Guerreschi, P

    2017-04-01

    Cleft palate requires surgery in the first years of life, furthermore repairing anatomically the soft and hard palate is complex on a surgical level because of the fine tissues and the local intraoral configuration. It is valuable to train first on simulators before going to the operating room. However, there is no material dedicated to learning how to perform intraoral sutures in cleft palate surgery. We made one, in an artisanal manner, in order to practice before the real surgical gesture. The simulator was designed based on precise anatomical data. A steel pipe, fixed on a rigid base represented the oral cavity. An adapted split spoon represented the palate. All pieces could be removed in order to apply a hydrocellular dressing before training for sutures. Our simulator was tested by 3 senior surgeons in our department in close to real-life conditions in order to evaluate its anatomical accuracy. It is valuable to have a simulator to train on cleft palate sutures within teaching university hospitals that manage this pathology. Our simulator has a very low cost, it is easy to make and is anatomically accurate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. A COMPARISON OF TWO DIFFERENT DOSES OF DEXMEDETOMIDINE INFUSION DURING MAINTENANCE OF GENERAL ANAESTHESIA IN PATIENTS UNDERGOING SPINE SURGERIES, FUNCTIONAL ENDOSCOPIC SINUS SURGERY AND MIDDLE EAR SURGERIES

    Directory of Open Access Journals (Sweden)

    Bijay

    2016-03-01

    Full Text Available BACKGROUND This study is undertaken to compare the hemodynamic effects and reduction in the doses of volatile anaesthetics and muscle relaxants using two different doses of dexmedetomidine infusion during maintenance of anaesthesia in spine, functional endoscopic sinus surgery and middle ear surgeries. METHODS Sixty patients are randomly divided into 2 groups of 30 each. After shifting to the operation theatre baseline vitals were recorded. Anesthesia induced with thiopentone sodium and intubation done with the help of succinylcholine and maintained with oxygen, nitrous oxide and isoflurane. After 1 min of intubation, maintenance infusion of dexmedetomidine (0.4 mcg/kg/hr and 0.7 mcg/kg/hr for patients allotted in 2 separate groups was started and stopped 15 min before end of surgery. Hemodynamic parameters and any reduction in the doses of volatile anaesthetics and muscle relaxants was noted. RESULTS Dexmedetomidine infusion (0.4 mcg/kg/hr and 0.7 mcg/kg/hr in both groups reduced the requirements of muscle relaxants and volatile anaesthetics. Hemodynamic stability was better in the group receiving 0.4 mcg/kg/hr. Patients receiving 0.7 mcg/kg/hr had higher incidence of hypotension, bradycardia and delayed emergence from anaesthesia. CONCLUSION Dexmedetomidine infusion at 0.4 mcg/kg/hr during maintenance of anaesthesia in spine surgery, FESS and middle ear surgery would be good option to reduce the requirements of volatile anaesthetics, muscle relaxants and for better hemodynamic stability. OBJECTIVE OF STUDY: Primary Objective To compare and evaluate the hemodynamic effects and reduction in requirements of volatile anaesthetics and muscle relaxants with two different doses of dexmedetomidine infusion during maintenance of general anaesthesia in patients undergoing spine, FESS and middle ear surgeries.

  12. Developing effective automated feedback in temporal bone surgery simulation.

    Science.gov (United States)

    Wijewickrema, Sudanthi; Piromchai, Patorn; Zhou, Yun; Ioannou, Ioanna; Bailey, James; Kennedy, Gregor; O'Leary, Stephen

    2015-06-01

    We aim to test the effectiveness, accuracy, and usefulness of an automated feedback system in facilitating skill acquisition in virtual reality surgery. We evaluate the performance of the feedback system through a randomized controlled trial of 24 students allocated to feedback and nonfeedback groups. The feedback system was based on the Melbourne University temporal bone surgery simulator. The study was conducted at the simulation laboratory of the Royal Victorian Eye and Ear Hospital, Melbourne. The study participants were medical students from the University of Melbourne, who were asked to perform virtual cortical mastoidectomy on the simulator. The extent to which the drilling behavior of the feedback and nonfeedback groups differed was used to evaluate the effectiveness of the system. Its accuracy was determined through a postexperiment observational assessment of recordings made during the experiment by an expert surgeon. Its usability was evaluated using students' self-reports of their impressions of the system. A Friedman's test showed that there was a significant improvement in the drilling performance of the feedback group, χ(2)(1) = 14.450, P feedback (when trainee behavior was detected) 88.6% of the time and appropriate feedback (accurate advice) 84.2% of the time. Participants' opinions about the usefulness of the system were highly positive. The automated feedback system was observed to be effective in improving surgical technique, and the provided feedback was found to be accurate and useful. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  13. Dexmedetomidine infusion during middle ear surgery under general anaesthesia to provide oligaemic surgical field: A prospective study

    Directory of Open Access Journals (Sweden)

    Kumkum Gupta

    2015-01-01

    Full Text Available Background and Aims: Middle ear surgery requires bloodless surgical field for better operating conditions, deep level of anaesthesia and rapid emergence. Recent studies suggest that α2 agonists could provide desired surgical field, sedation and analgesia. The present study was aimed to evaluate the clinical effects of dexmedetomidine infusion as anaesthetic adjuvant during middle ear surgery using operating microscope. Methods: Sixty four adult patients aged 18-58 years, American Society of Anaesthesiologists Grades I and II, of both gender were randomised into two comparable equal groups of 32 patients each for middle ear surgery under general anaesthesia with standard anaesthetic technique. After induction of general anaesthesia, patients of Group I were given dexmedetomidine infusion of 0.5 μg/kg/h and patients of Group II were given placebo infusion of normal saline. Isoflurane concentration was titrated to achieve a systolic blood pressure 30% below the baseline value. All patients were assessed intra-operatively for bleeding at surgical field, haemodynamic changes, awakening time and post-operative recovery. Results: Statistically significant reduction was observed in the required percentage of isoflurane (0.8 ± 0.6% to maintain the systolic blood pressure 30% below the baseline values in patients receiving dexmedetomidine infusion when compared to those receiving placebo infusion (1.6 ± 0.7%. Patients receiving dexmedetomidine infusion had statistically significant lesser bleeding at surgical field (P < 0.05. The mean awakening time and recovery from anaesthesia did not show any significant difference between the groups. Conclusion: Dexmedetomidine infusion can be safely used to provide oligaemic surgical field for better visualization using operating microscope for middle ear surgery.

  14. Surgical simulators in cataract surgery training.

    Science.gov (United States)

    Sikder, Shameema; Tuwairqi, Khaled; Al-Kahtani, Eman; Myers, William G; Banerjee, Pat

    2014-02-01

    Virtual simulators have been widely implemented in medical and surgical training, including ophthalmology. The increasing number of published articles in this field mandates a review of the available results to assess current technology and explore future opportunities. A PubMed search was conducted and a total of 10 articles were reviewed. Virtual simulators have shown construct validity in many modules, successfully differentiating user experience levels during simulated phacoemulsification surgery. Simulators have also shown improvements in wet-lab performance. The implementation of simulators in the residency training has been associated with a decrease in cataract surgery complication rates. Virtual reality simulators are an effective tool in measuring performance and differentiating trainee skill level. Additionally, they may be useful in improving surgical skill and patient outcomes in cataract surgery. Future opportunities rely on taking advantage of technical improvements in simulators for education and research.

  15. Virtual reality training for improving the skills needed for performing surgery of the ear, nose or throat.

    Science.gov (United States)

    Piromchai, Patorn; Avery, Alex; Laopaiboon, Malinee; Kennedy, Gregor; O'Leary, Stephen

    2015-09-09

    Virtual reality simulation uses computer-generated imagery to present a simulated training environment for learners. This review seeks to examine whether there is evidence to support the introduction of virtual reality surgical simulation into ear, nose and throat surgical training programmes. 1. To assess whether surgeons undertaking virtual reality simulation-based training achieve surgical ('patient') outcomes that are at least as good as, or better than, those achieved through conventional training methods.2. To assess whether there is evidence from either the operating theatre, or from controlled (simulation centre-based) environments, that virtual reality-based surgical training leads to surgical skills that are comparable to, or better than, those achieved through conventional training. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2015, Issue 6); PubMed; EMBASE; ERIC; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 27 July 2015. We included all randomised controlled trials and controlled trials comparing virtual reality training and any other method of training in ear, nose or throat surgery. We used the standard methodological procedures expected by The Cochrane Collaboration. We evaluated both technical and non-technical aspects of skill competency. We included nine studies involving 210 participants. Out of these, four studies (involving 61 residents) assessed technical skills in the operating theatre (primary outcomes). Five studies (comprising 149 residents and medical students) assessed technical skills in controlled environments (secondary outcomes). The majority of the trials were at high risk of bias. We assessed the GRADE quality of evidence for most outcomes across studies as 'low'. Operating theatre environment (primary outcomes) In

  16. Surgery simulation using fast finite elements

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten

    1996-01-01

    This paper describes our recent work on real-time surgery simulation using fast finite element models of linear elasticity. In addition, we discuss various improvements in terms of speed and realism......This paper describes our recent work on real-time surgery simulation using fast finite element models of linear elasticity. In addition, we discuss various improvements in terms of speed and realism...

  17. Micro-endoscopic ear anatomy of guinea pig applied to experimental surgery.

    Science.gov (United States)

    Barros, Bruno Borges de Carvalho; Andrade, José Santos Cruz de; Garcia, Leandro Borborema; Pifaia, Gustavo Ribeiro; Cruz, Oswaldo Laércio Mendonça; Onishi, Ektor Tsuneo; Penido, Norma de Oliveira

    2014-01-01

    To describe topographic and endoscopic anatomy of guinea pig ear for development of surgical approaches in experimental studies. Experimental study. Eight adult guinea pigs (Cavia porcellus) were used in this study. Four animals were described through endoscopic view and four animals were used to describe topographic anatomy. The main structures of middle ear were well identified through endoscopy view: oval and round window, ossicles and vascular structures. Temporal bone position, landmarks and its relations to skull are perceived with topographic description. Topographic anatomic description allowed exposition of temporal bone relations for external surgical approaches. Alternatively, grooves and middle ear structures were identified and may be used to transcanal accesses.

  18. Simulation-based certification for cataract surgery

    DEFF Research Database (Denmark)

    Thomsen, Ann Sofia Skou; Kiilgaard, Jens Folke; Kjaerbo, Hadi

    2015-01-01

    PURPOSE: To evaluate the EyeSi(™) simulator in regard to assessing competence in cataract surgery. The primary objective was to explore all simulator metrics to establish a proficiency-based test with solid evidence. The secondary objective was to evaluate whether the skill assessment was specific...

  19. Low-Cost Simulation of Robotic Surgery

    DEFF Research Database (Denmark)

    Grande, Kasper; Jensen, Rasmus Steen; Kraus, Martin

    2013-01-01

    The high expenses associated with acquiring and maintaining robotic surgical equipment for minimally invasive surgery entail that training on this equipment is also expensive. Virtual reality (VR) training simulators can reduce this training time; however, the current simulators are also quite...

  20. Fast finite elements for surgery simulation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten

    1997-01-01

    This paper discusses volumetric deformable models for modeling human body parts and organs in surgery simulation systems. These models are built using finite element models for linear elastic materials. To achieve real-time response condensation has been applied to the system stiffness matrix...

  1. Fascioperichondrial Flap with a Proximal Base Combined with Prominent Ear Surgery

    Directory of Open Access Journals (Sweden)

    Heval Selman Özkan

    2017-08-01

    Full Text Available Objective: In this article, we present a personalized surgical technique to relocate a fascioperichondrial flap with a proximal base as an additional measure to improve results and hide sharp edges which frequently occur following traditional otoplasty. Materials and Methods: Fascioperichondrial flap with a proximal base prepared from the dorsal side was transposed to the anterior helix and conchal excision side and secured with stitches to hide visible edges and reinforce Furnas sutures. Nine patients operated for prominent ear deformity using this modification were included in the study and follow-up period was at least 6 months. Conchal mastoid distances were calculated from the superior and middle third of the ears before and after the operation, also in follow-up controls to determine the efficiency of the method. Results: There were no suture extrusions, skin necrosis or infection. The mean difference for both the upper and middle third of the ears were considerably lower (p≤0.05 at the end of six month after the operation. There were no visible skin edges and discomfort described by the patients. Conclusion: Fascioperichondrial flap with a proximal base repositioning to conchal side is an easy procedure that can be applied simply as an adjunct to traditional techniques. Addition of this flap provides an additional tissue to reinforce suture repair and, the results seem to be more durable and strong. Another main advantage of this flap is eliminating the unnatural visible breakpoints in the conchal bowl.

  2. Ear Infection (Middle Ear)

    Science.gov (United States)

    ... secretions from the middle ear Swelling, inflammation and mucus in the eustachian tubes from an upper respiratory ... your baby for at least six months. Breast milk contains antibodies that may offer protection from ear ...

  3. Intraear Compensation of Field Corn, Zea mays, from Simulated and Naturally Occurring Injury by Ear-Feeding Larvae.

    Science.gov (United States)

    Steckel, S; Stewart, S D

    2015-06-01

    Ear-feeding larvae, such as corn earworm, Helicoverpa zea Boddie (Lepidoptera: Noctuidae), can be important insect pests of field corn, Zea mays L., by feeding on kernels. Recently introduced, stacked Bacillus thuringiensis (Bt) traits provide improved protection from ear-feeding larvae. Thus, our objective was to evaluate how injury to kernels in the ear tip might affect yield when this injury was inflicted at the blister and milk stages. In 2010, simulated corn earworm injury reduced total kernel weight (i.e., yield) at both the blister and milk stage. In 2011, injury to ear tips at the milk stage affected total kernel weight. No differences in total kernel weight were found in 2013, regardless of when or how much injury was inflicted. Our data suggested that kernels within the same ear could compensate for injury to ear tips by increasing in size, but this increase was not always statistically significant or sufficient to overcome high levels of kernel injury. For naturally occurring injury observed on multiple corn hybrids during 2011 and 2012, our analyses showed either no or a minimal relationship between number of kernels injured by ear-feeding larvae and the total number of kernels per ear, total kernel weight, or the size of individual kernels. The results indicate that intraear compensation for kernel injury to ear tips can occur under at least some conditions. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Silicone Foley′s catheter: A useful splint in ear surgeries

    Directory of Open Access Journals (Sweden)

    Karanth Siddharth

    2008-01-01

    Full Text Available Maintenance of ear projection and post auricular sulcus in staged ear reconstruction in microtia is a trying problem. So also is the maintenance of the patency of the external auditory meatus following recanalization and meatoplasty. Numerous splints and dressing techniques have been described for the above situations. Some of the problems encountered include the availability of the materials, cost, expertise in fabrication and compliance. Aims: To devise a simple, reliable, inexpensive and readily available splint for the maintenance of post auricular sulcus and external auditory meatus opening. Settings and Design: A silicone catheter is made out of a soft and inert material that doesn′t cause tissue necrosis or any loss of skin graft. The basic design is that of a simple, self-retaining type of splint that doesn′t dislodge and can be prepared within minutes on the operating table. Materials and Methods: This splint has been used in four cases of microtia reconstruction and one case of congenital external auditory meatus stenosis between June 2006 and August 2007. A 14 or 16 Fr silicone Foley′s catheter was used. The proximal end of a catheter of required length was retained and the distal part was cut off. The catheter was looped into a circle around the base of the reconstructed ear and secured in position with a suture. A similar construct was used in cases of external auditory meatus reconstruction or recanalization. The funnel-shaped distal drainage end was sutured to the circular frame near the region of the tragus. This funnel was inserted into the external auditory canal. Results: The catheter was found to sit snugly in the newly created sulcus, thereby maintaining the sulcus and ear projection. It aided in maintaining the meatal opening of a satisfactory diameter in the case of external auditory canal recanalization. It was never found to slip or get dislodged in any of the cases. There was no skin graft loss or tissue necrosis

  5. Endoscopy-Assisted Ear Surgery for Treatment of Chronic Otitis Media With Cholesteatoma, Adhesion, or Retraction Pockets.

    Science.gov (United States)

    Ulku, Cagatay Han

    2017-06-01

    The objective of this study was to analyze the results of endoscopy-assisted ear surgery for the treatment of chronic otitis media with cholesteatoma, adhesion, or retraction pockets.Fifty-one patients who underwent oto-endoscopy-assisted canal wall up tympanomastoid surgery and/or limited anterior atticotomy with tympanoplasty for chronic otitis media with cholesteatoma, adhesion, or retraction pocket from 2006 to 2013 have been included in this study. Eradication of the disease from the middle ear and mastoid air cells was achieved by combination of the oto-microscobic and oto-endoscopic approaches. Second look surgery was performed 18 months later from the initial surgery in selected patients. Age, gender, pre-/postoperative otoscopy findings/audiograms, type of the used prostheses, and follow-up time were obtained from the patient's file. Anatomic integrity rates of the tympanic membrane, the mean gains of air bone gap, on pure-tone audiogram at 4 frequencies and existence of the residual disease were reviewed parameters. Functional evaluation was made in patients with intact tympanic membrane.Of the 51 patients, the ratios of the chronic otitis media with cholesteatoma and isolated adhesive otitis or retraction pocket cases were 74.5% (38/51) and 25.5% (13/51), respectively. Ossicular chain reconstruction was made with PORP in 27 patients and TORP in 20 patients, whereas the ossicular chain was intact in 4 patients. Anatomic integrity rates of the tympanic membrane were 90.2% (46/51). The overall (n = 46) pre-/postoperative mean ABG obtained at 4 frequencies were 28.3 ± 12.26 and 9.18 ± 5.68 dB (P otitis media with cholesteatoma patients. However, there was no recurrence or new cholesteatoma formation in isolated retraction pockets or adhesive otitis patients.Oto-endoscopic eradication of the cholesteatoma or epithelial tissue from hidden area after the all visible cholesteatoma removal by oto-microscope improves the quality of surgery

  6. Incorporating simulation in vascular surgery education.

    Science.gov (United States)

    Bismuth, Jean; Donovan, Michael A; O'Malley, Marcia K; El Sayed, Hosam F; Naoum, Joseph J; Peden, Eric K; Davies, Mark G; Lumsden, Alan B

    2010-10-01

    The traditional apprenticeship model introduced by Halsted of "learning by doing" may just not be valid in the modern practice of vascular surgery. The model is often criticized for being somewhat unstructured because a resident's experience is based on what comes through the "door." In an attempt to promote uniformity of training, multiple national organizations are currently delineating standard curricula for each trainee to govern the knowledge and cases required in a vascular residency. However, the outcomes are anything but uniform. This means that we graduate vascular specialists with a surprisingly wide spectrum of abilities. Use of simulation may benefit trainees in attaining a level of technical expertise that will benefit themselves and their patients. Furthermore, there is likely a need to establish a simulation-based certification process for graduating trainees to further ascertain minimum technical abilities. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  7. Prominent ears: the effect of reconstructive surgery on self-esteem and social interaction in children with a minor defect compared to children with a major orthopedic defect.

    Science.gov (United States)

    Niemelä, Birgitta Johansson; Hedlund, Anders; Andersson, Gerhard; Wahlsten, Viveka Sundelin

    2008-11-01

    In a prospective study of patients with prominent ears, the effect of reconstructive surgery on self-esteem and social interaction was examined 1 year after surgery. Of 42 patients with prominent ears aged 7 to 15 years, 21 were matched with a comparison group of orthopedic patients (leg lengthening) and a control group of schoolchildren. Psychological measures evaluated self-esteem, depression, anxiety, cognition, parents' ratings of child behavior and symptoms, and parent anxiety. Semistructured interviews with the child and parents were also conducted. The motivation to be operated on was pain, teasing, and feelings of being different. The satisfaction rate with the result of reconstructive surgery was high. The psychological measures of the prominent ears group had results close to those of the control group, although the leg lengthening group had lower self-esteem and higher depression and anxiety scores. With few exceptions, all patients had scores within the normal range on self-rating scales. Parents reported less activity at leisure time in both patient groups than in the control group. After surgery, parents reported improved behavior on the Child Behavior Checklist total problem score. Patients with minor defects had fewer self-reported psychological and behavior problems than the major defect group. Interestingly, prominent ears patients also had low activity levels. Reconstructive surgery had no adverse effect on the prominent ears patients in this interim study but rather resulted in improved well-being. It is important to investigate further the effect of reconstructive surgery on children's self-esteem and social interaction.

  8. SIMULATION OF A COCHLEA OF AN INTERIOR EAR OF THE HUMAN

    Directory of Open Access Journals (Sweden)

    S. A. Naida

    2012-12-01

    Full Text Available There was conducted the simulations of a cochlea of an interior ear of the human by means of a long line. The following regularities of operation of a cochlea were determined: without the count of flexibilities Reissner's and basilar membranes swing pressure on walls of a cochlear course does not exceed 3,6 % from pressure in the field of an oval window; allocation of a differential of sound pressure fluctuates in a time with frequency; taking into account the slenderness of a membrane and dependence of a standing of resonances from f are spotted by non-uniformity of a basilar membrane; the differential travelling wave exists only near to a resonance on each  frequency where the amplitude buildup of oscillations to a maximum happens for many continuances of resonance frequency. Small relative meaning of range of pressure of travelling wave could become the parent of that Peterson's and Bogert's work has not had the further evolution.

  9. Ear Injury

    Science.gov (United States)

    ... of different injuries can affect the outer ear. Cauliflower ear (subperichondrial hematoma) A blunt blow to the ... to a deformed ear. This deformity, called a cauliflower ear, is common among wrestlers, boxers, and rugby ...

  10. Bone-anchored hearing aid (BAHA: indications, functional results, and comparison with reconstructive surgery of the ear

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2012-01-01

    Full Text Available Introduction: The bone-anchored hearing aid (BAHA is a bone conduction hearing device that transmits sound directly into the inner ear. It is mainly used in patients with conductive hearing loss associated with aural atresia, but it is also used in those with mixed and sensorineural hearing loss. Goals: To review the main indications for BAHA, to analyze the audiometric results and its benefits for patients and compare them with other treatment modalities, and to compare the literature data with our sample of 13 patients. Method: The research was performed using a database covering works in English, Spanish, and Portuguese, with no limitations in the years when the procedures were performed. We compared the literature data with our results for the 13 patients who underwent BAHA implantation between the years 2000 and 2009. Results: Most of the studies showed that BAHA has great advantages over reconstructive surgery in terms of hearing results, complications, and disease recurrence. The postoperative results for our 13 patients were satisfactory and comparable with the results from the literature, with closure of the air-bone gap in 7 patients and achieving an air-bone gap of 10 dB in 6 patients. No postoperative complications were observed. Conclusion: BAHA is a better treatment option than reconstructive surgery for patients with bilateral deafness. It is a relatively simple surgical procedure with few complications and good hearing results. Recent studies have examined its use in conductive and unilateral sensorineural hearing loss.

  11. CUDA-based real time surgery simulation.

    Science.gov (United States)

    Liu, Youquan; De, Suvranu

    2008-01-01

    In this paper we present a general software platform that enables real time surgery simulation on the newly available compute unified device architecture (CUDA)from NVIDIA. CUDA-enabled GPUs harness the power of 128 processors which allow data parallel computations. Compared to the previous GPGPU, it is significantly more flexible with a C language interface. We report implementation of both collision detection and consequent deformation computation algorithms. Our test results indicate that the CUDA enables a twenty times speedup for collision detection and about fifteen times speedup for deformation computation on an Intel Core 2 Quad 2.66 GHz machine with GeForce 8800 GTX.

  12. Medical Image Registration and Surgery Simulation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten

    1996-01-01

    This thesis explores the application of physical models in medical image registration and surgery simulation. The continuum models of elasticity and viscous fluids are described in detail, and this knowledge is used as a basis for most of the methods described here. Real-time deformable models......, and the use of selective matrix vector multiplication. Fluid medical image registration A new and faster algorithm for non-rigid registration using viscous fluid models is presented. This algorithm replaces the core part of the original algorithm with multi-resolution convolution using a new filter, which...... growth is also presented. Using medical knowledge about the growth processes of the mandibular bone, a registration algorithm for time sequence images of the mandible is developed. Since this registration algorithm models the actual development of the mandible, it is possible to simulate the development...

  13. Swimmer's Ear

    Science.gov (United States)

    ... Eardrum Taking Care of Your Ears Can Loud Music Hurt My Ears? Your Ears What's Earwax? How Do Pain Relievers Work? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  14. The risk of acquiring bacterial meningitis following surgery in Denmark, 1996-2009: a nationwide retrospective cohort study with emphasis on ear, nose and throat (ENT) and neurosurgery.

    Science.gov (United States)

    Howitz, M F; Homøe, P

    2014-06-01

    This paper estimates the risk of bacterial meningitis following surgery between 1996 and 2009 in Denmark. We conducted two retrospective nationwide cohort studies; first by linking notified bacterial meningitis cases to the National Patient Registry to see how many had undergone a surgical procedure; second, we scrutinized notified bacterial meningitis cases to see if the clinician suspected a surgical procedure to be the aetiology. We found that ear, nose and throat surgery had an 11-fold, and neurosurgery a sevenfold, increased risk compared to the reference group in the first 10 days following surgery. Streptococcus pneumoniae was the pathogen most often involved. Operation procedures involving penetration of dura mater was associated with increased risk for post-operative bacterial meningitis. In absolute numbers we found few bacterial meningitis cases after surgery; however, patients undergoing certain surgical procedures are at-risk and should be considered when national vaccination guidelines are revised.

  15. Comparison of the Effect of Ondansetrone - Dexamethasone, Dexamethasone – Metoclopeamide and Ondansetron - Normal Saline in Decreasing Post Operative Nausa and Vomitting (PONV after Middle Ear Surgery

    Directory of Open Access Journals (Sweden)

    Haddadi Soudabeh

    2009-09-01

    Full Text Available Background: The incidence of post-operative nausea and vomitting (PONV is increased after middle ear surgery and it may complicate and interact with reconstruction after surgery, so prevention and treatment of these complications are necessary.The aim of this study was to evaluate the efficacy of anti-emetic combinations in decreasing the PONV after middle ear surgery.Materials and methods: This double blind clinical trial was carried out during 2007-2008 on 111 patients of 15-45 years old with ASA I-II who were candidates for elective middle ear surgery under general anesthesia. The patients were divided into three groups. Patients in the ON group received Ondansetrone 0.1mg/kg + Nacl 0.9% 2cc, OD group received Ondansetrone 0.1mg/kg + Dexamethasone 0.15mg/kg and MD group received Dexamethasone 0.15mg/kg+ Metoclopramide 0.15mg/kg intravenously just before the end of surgery. The patients were evaluated for nausea, vomiting, need of anti-emetic drugs and drug dosage in recovery, 1-6, 6-12 and 12-24 hours after operation and then all data were statistically analyzed by SPSS software, Chi-square, ANOVA and t- Test. P<0.05 was significant.Results: There were no significant differences among three groups in age and sex. The incidence of PONV among 3 groups was not significantly different during 24 hours after operation. (P=0.271 but the incidence of PONV in the first six hours was different among 3 groups (P=0.007 (ON: 8.1%, OD: 0%, MD: 21.6%. Also Metoclopramide consumption was significant between three groups. Conclusion: This study showed that the need to anti-emetic drugs in first 6 hours was the least in OD group, but the difference in the incidence of PONV was not significant otherwise.

  16. Ear wax

    Science.gov (United States)

    See your provider if your ears are blocked with wax and you are unable to remove the wax. Also call if you have an ear wax blockage and you develop new symptoms, such as: Drainage from the ear Ear pain Fever Hearing loss that continues after you clean the wax

  17. Ear Pieces

    Science.gov (United States)

    DiJulio, Betsy

    2011-01-01

    In this article, the author describes an art project wherein students make fanciful connections between art and medicine. This project challenges students to interpret "ear idioms" (e.g. "blow it out your ear," "in one ear and out the other") by relying almost entirely on realistic ear drawings, the placement of them, marks, and values. In that…

  18. Ear Plastic Surgery

    Science.gov (United States)

    ... Inquiries Find an ENT News About Us Our Campaigns Foundation Governance Diversity Honorary Awards & Lectures Employment Opportunities Renting Space Advocacy Medicare Advocacy Legislative & Political Affairs ENT PAC foundation Guidelines Patient Health Quality ...

  19. Geranisetron versus gabapentin in preventing postoperative nausea and vomiting after middle ear surgery in adults: A double-blinded randomized clinical trial study

    Directory of Open Access Journals (Sweden)

    Morteza Heidari

    2015-01-01

    Full Text Available Background: The incidence of postoperative nausea and vomiting (PONV after middle ear surgery is high. In this study we want to compare the effects of intravenous granisetron and oral gabapentin as a premedication before surgery on the incidence and severity of PONV after middle ear surgery in adult patents. Materials and Methods: We enrolled 90 patients that were randomly divided into the three groups of 30 in each. Group I received granisetron 3 mg iv 2 minutes before induction of anesthesia; Group II received oral gabapentin 300 mg 1 hour before anesthesia and Group III received placebo. The incidence and severity of PONV were recorded each 15 minutes in the post-anesthesia care unit (PACU and each 8 hours until 24 hours after discharge from the PACU. Result: The incidence and severity of nausea and vomiting at different time intervals in Groups I and Group II was significantly lower compared with Group III (P < 0.05. There was no significant difference in the incidence of side effects of study drug administration including respiratory depression, apnea, extra pyramidal disorders, drowsiness, dizziness, vertigo and headache in three groups. Conclusion: The study was shown that using gabapentin and granisetron have equal anti-emetic effects, but significant differences were seen between these two groups compared to the control group. These submit the efficiency of these drugs in preventing PONV.

  20. Increasing safety of a robotic system for inner ear surgery using probabilistic error modeling near vital anatomy

    Science.gov (United States)

    Dillon, Neal P.; Siebold, Michael A.; Mitchell, Jason E.; Blachon, Gregoire S.; Balachandran, Ramya; Fitzpatrick, J. Michael; Webster, Robert J.

    2016-03-01

    Safe and effective planning for robotic surgery that involves cutting or ablation of tissue must consider all potential sources of error when determining how close the tool may come to vital anatomy. A pre-operative plan that does not adequately consider potential deviations from ideal system behavior may lead to patient injury. Conversely, a plan that is overly conservative may result in ineffective or incomplete performance of the task. Thus, enforcing simple, uniform-thickness safety margins around vital anatomy is insufficient in the presence of spatially varying, anisotropic error. Prior work has used registration error to determine a variable-thickness safety margin around vital structures that must be approached during mastoidectomy but ultimately preserved. In this paper, these methods are extended to incorporate image distortion and physical robot errors, including kinematic errors and deflections of the robot. These additional sources of error are discussed and stochastic models for a bone-attached robot for otologic surgery are developed. An algorithm for generating appropriate safety margins based on a desired probability of preserving the underlying anatomical structure is presented. Simulations are performed on a CT scan of a cadaver head and safety margins are calculated around several critical structures for planning of a robotic mastoidectomy.

  1. Ear examination

    Science.gov (United States)

    ... may be present. The eardrum is a light-gray color or a shiny pearly-white. Light should ... discharge or bleeding Alternative Names Otoscopy Images Ear anatomy Medical findings based on ear anatomy Otoscopic exam ...

  2. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  3. Computer Simulation and Digital Resources for Plastic Surgery Psychomotor Education.

    Science.gov (United States)

    Diaz-Siso, J Rodrigo; Plana, Natalie M; Stranix, John T; Cutting, Court B; McCarthy, Joseph G; Flores, Roberto L

    2016-10-01

    Contemporary plastic surgery residents are increasingly challenged to learn a greater number of complex surgical techniques within a limited period. Surgical simulation and digital education resources have the potential to address some limitations of the traditional training model, and have been shown to accelerate knowledge and skills acquisition. Although animal, cadaver, and bench models are widely used for skills and procedure-specific training, digital simulation has not been fully embraced within plastic surgery. Digital educational resources may play a future role in a multistage strategy for skills and procedures training. The authors present two virtual surgical simulators addressing procedural cognition for cleft repair and craniofacial surgery. Furthermore, the authors describe how partnerships among surgical educators, industry, and philanthropy can be a successful strategy for the development and maintenance of digital simulators and educational resources relevant to plastic surgery training. It is our responsibility as surgical educators not only to create these resources, but to demonstrate their utility for enhanced trainee knowledge and technical skills development. Currently available digital resources should be evaluated in partnership with plastic surgery educational societies to guide trainees and practitioners toward effective digital content.

  4. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    Directory of Open Access Journals (Sweden)

    Kozak I

    2014-03-01

    Full Text Available Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT scans from real patients for practicing vitreoretinal surgery using different pathologic scenarios.Keywords: optical coherence tomography

  5. Simulation-based summative assessments in surgery.

    Science.gov (United States)

    Szasz, Peter; Grantcharov, Teodor P; Sweet, Robert M; Korndorffer, James R; Pedowitz, Robert A; Roberts, Patricia L; Sachdeva, Ajit K

    2016-09-01

    The American College of Surgeons-Accredited Education Institutes (ACS-AEI) Consortium aims to enhance patient safety and advance surgical education through the use of cutting-edge simulation-based training and assessment methods. The annual ACS-AEI Consortium meeting provides a forum to discuss the latest simulation-based training and assessment methods and includes special panel presentations on key topics. During the 8th annual Consortium, there was a panel presentation on simulation-based summative assessments, during which experiences from across surgical disciplines were presented. The formal presentations were followed by a robust discussion between the conference attendees and the panelists. This report summarizes the panelists' presentations and their ensuing discussion with attendees. The focus of this report is on the basis for and advances in simulation-based summative assessments, the current practices employed across various surgical disciplines, and future directions that may be pursued by the ACS-AEI Consortium. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Avoiding the "pixie-ear" deformity following face lift surgery by differential insetting and secondary intention healing.

    Science.gov (United States)

    Mowlavi, Arian; Zakhireh, Mo

    2005-01-01

    The "pixie-ear" deformity has been described by its "stuck-on" or "pulled" appearance, due to the extrinsic pull of the cheek and jawline skin flaps on the earlobe attachment point (O), the otobasion inferius. The tension results in migration of the earlobe attachment point from a posterior cephalad position to an anterior caudal position. Recently, the 2 components of the earlobe, the attached cephalic segment (I to O distance) and the free caudal segment (O to S distance), have been defined. We describe a novel technique involving differential insetting of the cheek and jawline skin flaps to the earlobe and secondary intention healing to create an aesthetically pleasing cephalic attached segment. Rhytidectomy was performed using an extended superficial muscular aponeurotic system (SMAS) technique along with jawline undermining. The earlobe soft-tissue-retaining ligaments to the mastoid were released to the level of the new otobasion inferius to creat a cephalic attached segment less than 1.5 cm, which allowed the caudal free segment to approximate 0.5 cm. Whereas the cephalic segment was directly repaired, the free caudal segment anterior and posterior skin flaps were not reapproximated and were to heal by secondary intention. In a series of 20 consecutive patients, excellent aesthetic results were obtained using this approach without healing complications, hypertrophic scarring, or "pixie-ear" deformity. Our approach for cheek and jawline skin flap fixation to the earlobe eliminates any vector of pull on the free caudal segment of the earlobe and, consequently, any potential for "pixie-ear" formation. We advocate allowing the free caudal segment to heal by secondary intention, which results in the medial edge of the free caudal earlobe attaining a curved and blunt-edged appearance that is aesthetically superior to primary repair.

  7. Validation of a Novel Virtual Reality Simulator for Robotic Surgery

    Directory of Open Access Journals (Sweden)

    Henk W. R. Schreuder

    2014-01-01

    Full Text Available Objective. With the increase in robotic-assisted laparoscopic surgery there is a concomitant rising demand for training methods. The objective was to establish face and construct validity of a novel virtual reality simulator (dV-Trainer, Mimic Technologies, Seattle, WA for the use in training of robot-assisted surgery. Methods. A comparative cohort study was performed. Participants (n=42 were divided into three groups according to their robotic experience. To determine construct validity, participants performed three different exercises twice. Performance parameters were measured. To determine face validity, participants filled in a questionnaire after completion of the exercises. Results. Experts outperformed novices in most of the measured parameters. The most discriminative parameters were “time to complete” and “economy of motion” (P<0.001. The training capacity of the simulator was rated 4.6 ± 0.5 SD on a 5-point Likert scale. The realism of the simulator in general, visual graphics, movements of instruments, interaction with objects, and the depth perception were all rated as being realistic. The simulator is considered to be a very useful training tool for residents and medical specialist starting with robotic surgery. Conclusions. Face and construct validity for the dV-Trainer could be established. The virtual reality simulator is a useful tool for training robotic surgery.

  8. Prevailing Trends in Haptic Feedback Simulation for Minimally Invasive Surgery.

    Science.gov (United States)

    Pinzon, David; Byrns, Simon; Zheng, Bin

    2016-08-01

    Background The amount of direct hand-tool-tissue interaction and feedback in minimally invasive surgery varies from being attenuated in laparoscopy to being completely absent in robotic minimally invasive surgery. The role of haptic feedback during surgical skill acquisition and its emphasis in training have been a constant source of controversy. This review discusses the major developments in haptic simulation as they relate to surgical performance and the current research questions that remain unanswered. Search Strategy An in-depth review of the literature was performed using PubMed. Results A total of 198 abstracts were returned based on our search criteria. Three major areas of research were identified, including advancements in 1 of the 4 components of haptic systems, evaluating the effectiveness of haptic integration in simulators, and improvements to haptic feedback in robotic surgery. Conclusions Force feedback is the best method for tissue identification in minimally invasive surgery and haptic feedback provides the greatest benefit to surgical novices in the early stages of their training. New technology has improved our ability to capture, playback and enhance to utility of haptic cues in simulated surgery. Future research should focus on deciphering how haptic training in surgical education can increase performance, safety, and improve training efficiency. © The Author(s) 2016.

  9. Comparison of palanosetron, granisetron and ondansetron as anti-emetics for prevention of postoperative nausea and vomiting in patients undergoing middle ear surgery.

    Science.gov (United States)

    Basu, Anjana; Saha, Debdas; Hembrom, Bani P; Roy, Amit; Naaz, Anjum

    2011-05-01

    The objective of the study was to compare the efficacy of palanosetron (0.25 mg), granisetron (3.0 mg) and ondansetron (8.0 mg) used as anti-emetics for the prevention of postoperative nausea/vomiting in patients undergoing middle ear surgery. The study was done among 75 adult patients (age group 30-45 years) of which 50 were males and rest (25) females, all of ASA I and ASA II. The patients were randomly allocated into 3 equal groups: Group I (n = 25) received injection palanosetron (0.25 mg) IV, group II (n = 25) received injection granisetron (3 mg) IV and group III (n = 25) received injection ondansetron (8.0 mg) IV at the end of the surgical procedure. A standard general anaesthesia technique was employed. Emetic episodes and safety assessments were performed during two periods of 0-6 hours in the postanaesthesia care unit and 6-24 hours in the ward after anaesthesia. The incidence of emesis-free patients during the 0-6 hours period was 100% for group I; 72% for group II and 56% for group III. During the 6-24 hours period incidence of emesis-free patients were 96% for group I; 56% for group II and 32% for group III. So to conclude, a single dose of palanosetron (0.25 mg) is a superior anti-emetic to granisetron (3.0 mg) or ondansetron (8.0 mg) in complete prevention of postoperative nausea and vomiting after middle ear surgery during the first 24 hours period.

  10. Your Ears

    Science.gov (United States)

    ... More on this topic for: Kids Can Loud Music Hurt My Ears? What Is an Ear Infection? Senses Experiment: Model Eardrum Going to the Audiologist What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  11. Virtual reality simulator for vitreoretinal surgery using integrated OCT data

    OpenAIRE

    Kozak, Igor; Banerjee,Pat; Luo,Jia; Luciano,Cristian

    2014-01-01

    Igor Kozak,1 Pat Banerjee,2 Jia Luo,2 Cristian Luciano21King Khaled Eye Specialist Hospital, Vitreoretinal Division, Riyadh, Kingdom of Saudi Arabia; 2College of Engineering, University of Illinois at Chicago, Chicago, IL, USAAbstract: Operative practice using surgical simulators has become a part of training in many surgical specialties, including ophthalmology. We introduce a virtual reality retina surgery simulator capable of integrating optical coherence tomography (OCT) scans from real p...

  12. Validation of a novel virtual reality simulator for robotic surgery

    NARCIS (Netherlands)

    Schreuder, Henk W. R.; Persson, Jan E. U.; Wolswijk, Richard G. H.; Ihse, Ingmar; Schijven, Marlies P.; Verheijen, René H. M.

    2014-01-01

    With the increase in robotic-assisted laparoscopic surgery there is a concomitant rising demand for training methods. The objective was to establish face and construct validity of a novel virtual reality simulator (dV-Trainer, Mimic Technologies, Seattle, WA) for the use in training of

  13. 3D printing to simulate laparoscopic choledochal surgery.

    Science.gov (United States)

    Burdall, Oliver C; Makin, Erica; Davenport, Mark; Ade-Ajayi, Niyi

    2016-05-01

    Laparoscopic simulation has transformed skills acquisition for many procedures. However, realistic nonbiological simulators for complex reconstructive surgery are rare. Life-like tactile feedback is particularly difficult to reproduce. Technological innovations may contribute novel solutions to these shortages. We describe a hybrid model, harnessing 3D technology to simulate laparoscopic choledochal surgery for the first time. Digital hepatic anatomy images and standard laparoscopic trainer dimensions were employed to create an entry level laparoscopic choledochal surgery model. The information was fed into a 3D systems project 660pro with visijet pxl core powder to create a free standing liver mold. This included a cuboid portal in which to slot disposable hybrid components representing hepatic and pancreatic ducts and choledochal cyst. The mold was used to create soft silicone replicas with T28 resin and T5 fast catalyst. The model was assessed at a national pediatric surgery training day. The 10 delegates that trialed the simulation felt that the tactile likeness was good (5.6/10±1.71, 10=like the real thing), was not too complex (6.2/10±1.35; where 1=too simple, 10=too complicated), and generally very useful (7.36/10±1.57, 10=invaluable). 100% stated that they felt they could reproduce this in their own centers, and 100% would recommend this simulation to colleagues. Though this first phase choledochal cyst excision simulation requires further development, 3D printing provides a useful means of creating specific and detailed simulations for rare and complex operations with huge potential for development. Copyright © 2016. Published by Elsevier Inc.

  14. Simulation training in video-assisted urologic surgery.

    Science.gov (United States)

    Hoznek, András; Salomon, Laurent; de la Taille, Alexandre; Yiou, René; Vordos, Dimitrios; Larre, Stéphane; Abbou, Clément-Claude

    2006-03-01

    The current system of surgical education is facing many challenges in terms of time efficiency, costs, and patient safety. Training using simulation is an emerging area, mostly based on the experience of other high-risk professions like aviation. The goal of simulation-based training in surgery is to develop not only technical but team skills. This learning environment is stress-free and safe, allows standardization and tailoring of training, and also objectively evaluate performances. The development of simulation training is straightforward in endourology, since these procedures are video-assisted and the low degree of freedom of the instruments is easily replicated. On the other hand, these interventions necessitate a long learning curve, training in the operative room is especially costly and risky. Many models are already in use or under development in all fields of video-assisted urologic surgery: ureteroscopy, percutaneous surgery, transurethral resection of the prostate, and laparoscopy. Although bench models are essential, simulation increasingly benefits from the achievements and development of computer technology. Still in its infancy, virtual reality simulation will certainly belong to tomorrow's teaching tools.

  15. Virtual reality simulators and training in laparoscopic surgery.

    Science.gov (United States)

    Yiannakopoulou, Eugenia; Nikiteas, Nikolaos; Perrea, Despina; Tsigris, Christos

    2015-01-01

    Virtual reality simulators provide basic skills training without supervision in a controlled environment, free of pressure of operating on patients. Skills obtained through virtual reality simulation training can be transferred on the operating room. However, relative evidence is limited with data available only for basic surgical skills and for laparoscopic cholecystectomy. No data exist on the effect of virtual reality simulation on performance on advanced surgical procedures. Evidence suggests that performance on virtual reality simulators reliably distinguishes experienced from novice surgeons Limited available data suggest that independent approach on virtual reality simulation training is not different from proctored approach. The effect of virtual reality simulators training on acquisition of basic surgical skills does not seem to be different from the effect the physical simulators. Limited data exist on the effect of virtual reality simulation training on the acquisition of visual spatial perception and stress coping skills. Undoubtedly, virtual reality simulation training provides an alternative means of improving performance in laparoscopic surgery. However, future research efforts should focus on the effect of virtual reality simulation on performance in the context of advanced surgical procedure, on standardization of training, on the possibility of synergistic effect of virtual reality simulation training combined with mental training, on personalized training. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  16. Realistic soft tissue deformation strategies for real time surgery simulation.

    Science.gov (United States)

    Shen, Yunhe; Zhou, Xiangmin; Zhang, Nan; Tamma, Kumar; Sweet, Robert

    2008-01-01

    A volume-preserving deformation method (VPDM) is developed in complement with the mass-spring method (MSM) to improve the deformation quality of the MSM to model soft tissue in surgical simulation. This method can also be implemented as a stand-alone model. The proposed VPDM satisfies the Newton's laws of motion by obtaining the resultant vectors form an equilibrium condition. The proposed method has been tested in virtual surgery systems with haptic rendering demands.

  17. Electrocoagulation improving bone cement use in middle-ear surgery: short-term and middle-term results.

    Science.gov (United States)

    Galy-Bernadoy, C; Akkari, M; Mondain, M; Uziel, A; Venail, F

    2016-12-01

    Bone cement is used for ossicular chain repair and revision stapes surgery. Its efficient use requires cautious removal of mucosa from the ossicles. This paper reports a technique for easy, fast and safe removal of this mucosa prior to cement application. It consists of the application of monopolar electrocoagulation on the ossicles prior to bone cement application. The outcomes of six cases of revision stapes surgery and seven cases of partial ossiculoplasty, conducted between 2007 and 2012 using this new technique, were evaluated. Intra-operative reports and audiometric data were collected. During the last assessment, reconstruction using bone cement resulted in mean post-operative air-bone gaps of 4.1 ± 6.5 dB in revision stapes surgery cases and 5.7 ± 5.5 dB in partial ossiculoplasty cases, reflecting a significant hearing improvement (p = 0.03). No complications were observed. Electrocoagulation allows the removal of mucosa from the ossicles in an easy, fast and safe manner, enabling the use of bone cement for ossicular chain reconstruction.

  18. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Don; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of); Yoo, Sun Kook; Lee, Kyoung Sang [Dept. of Medical Engineering, College of Medicine, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  19. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    International Nuclear Information System (INIS)

    Kim, Hyun Don; Park, Chang Seo; Yoo, Sun Kook; Lee, Kyoung Sang

    1998-01-01

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  20. The use of simulators in the learning for otologic surgery

    Directory of Open Access Journals (Sweden)

    Sousa, Ana Maria Almeida de

    2011-10-01

    Full Text Available Introduction: The teaching method of "learn by doing it'' was created by Halsted e col. In the beginning of 20th century creating the first model of medical residence in the world. This learning develops in three phases: cognitive, associative and autonomous, through an ascending curve. The simulators appeared in the last years as a complement to the cognitive phase, adding efforts to the training, performed before only in animals and cadavers, ever more hampered by medical and legal dilemmas. Objective: Describe and compare the various types of simulators available for the learning of otological surgery. Data synthesis: The model of simulators are divided mainly in real and virtual models, each having its peculiarities with positive and negative points. The main point of each one of them is the sensory feedback granted by each one of them, what we call it haptic reality: coloring of the structure dissected; listening to the corresponding sounds; as the drill or vacuum; presence of a joystick that simulates the pen motor; use of glasses or even a microscope for three dimensional view; use of a real otologic surgical instrument. The cost of the differents types of simulators is also a key point for the implementation of them in the daily reality of the training centers. Is important to mention that some of these simulators allow the training students and can be objectively evaluated by the simulator itself. Conclusion: Simulators are seen as a complementary tool for training and improvement of the otological surgeons.

  1. In-the-Ear Hearing-Instrument Antenna for ISM-Band Body-Centric Ear-to-Ear Communications

    DEFF Research Database (Denmark)

    Yatman, William H.; Larsen, Lauge K; Kvist, Søren Helstrup

    2012-01-01

    A compact 2.45 GHz slot-loop antenna is implemented for the use in the outer shell of an in-the-ear (ITE) hearing instrument (HI). The antenna is optimized for high ear-to-ear path gain (jS21j). The antenna simulation results are presented for two identical antennas, one placed in the center of e...

  2. Procedural virtual reality simulation in minimally invasive surgery.

    Science.gov (United States)

    Våpenstad, Cecilie; Buzink, Sonja N

    2013-02-01

    Simulation of procedural tasks has the potential to bridge the gap between basic skills training outside the operating room (OR) and performance of complex surgical tasks in the OR. This paper provides an overview of procedural virtual reality (VR) simulation currently available on the market and presented in scientific literature for laparoscopy (LS), flexible gastrointestinal endoscopy (FGE), and endovascular surgery (EVS). An online survey was sent to companies and research groups selling or developing procedural VR simulators, and a systematic search was done for scientific publications presenting or applying VR simulators to train or assess procedural skills in the PUBMED and SCOPUS databases. The results of five simulator companies were included in the survey. In the literature review, 116 articles were analyzed (45 on LS, 43 on FGE, 28 on EVS), presenting a total of 23 simulator systems. The companies stated to altogether offer 78 procedural tasks (33 for LS, 12 for FGE, 33 for EVS), of which 17 also were found in the literature review. Although study type and used outcomes vary between the three different fields, approximately 90 % of the studies presented in the retrieved publications for LS found convincing evidence to confirm the validity or added value of procedural VR simulation. This was the case in approximately 75 % for FGE and EVS. Procedural training using VR simulators has been found to improve clinical performance. There is nevertheless a large amount of simulated procedural tasks that have not been validated. Future research should focus on the optimal use of procedural simulators in the most effective training setups and further investigate the benefits of procedural VR simulation to improve clinical outcome.

  3. Virtual reality applied to hepatic surgery simulation: the next revolution.

    Science.gov (United States)

    Marescaux, J; Clément, J M; Tassetti, V; Koehl, C; Cotin, S; Russier, Y; Mutter, D; Delingette, H; Ayache, N

    1998-11-01

    This article describes a preliminary work on virtual reality applied to liver surgery and discusses the repercussions of assisted surgical strategy and surgical simulation on tomorrow's surgery. Liver surgery is considered difficult because of the complexity and variability of the organ. Common generic tools for presurgical medical image visualization do not fulfill the requirements for the liver, restricting comprehension of a patient's specific liver anatomy. Using data from the National Library of Medicine, a realistic three-dimensional image was created, including the envelope and the four internal arborescences. A computer interface was developed to manipulate the organ and to define surgical resection planes according to internal anatomy. The first step of surgical simulation was implemented, providing the organ with real-time deformation computation. The three-dimensional anatomy of the liver could be clearly visualized. The virtual organ could be manipulated and a resection defined depending on the anatomic relations between the arborescences, the tumor, and the external envelope. The resulting parts could also be visualized and manipulated. The simulation allowed the deformation of a liver model in real time by means of a realistic laparoscopic tool. Three-dimensional visualization of the organ in relation to the pathology is of great help to appreciate the complex anatomy of the liver. Using virtual reality concepts (navigation, interaction, and immersion), surgical planning, training, and teaching for this complex surgical procedure may be possible. The ability to practice a given gesture repeatedly will revolutionize surgical training, and the combination of surgical planning and simulation will improve the efficiency of intervention, leading to optimal care delivery.

  4. Validation of Robotic Surgery Simulator (RoSS).

    Science.gov (United States)

    Kesavadas, Thenkurussi; Stegemann, Andrew; Sathyaseelan, Gughan; Chowriappa, Ashirwad; Srimathveeravalli, Govindarajan; Seixas-Mikelus, Stéfanie; Chandrasekhar, Rameella; Wilding, Gregory; Guru, Khurshid

    2011-01-01

    Recent growth of daVinci Robotic Surgical System as a minimally invasive surgery tool has led to a call for better training of future surgeons. In this paper, a new virtual reality simulator, called RoSS is presented. Initial results from two studies - face and content validity, are very encouraging. 90% of the cohort of expert robotic surgeons felt that the simulator was excellent or somewhat close to the touch and feel of the daVinci console. Content validity of the simulator received 90% approval in some cases. These studies demonstrate that RoSS has the potential of becoming an important training tool for the daVinci surgical robot.

  5. Virtual reality based surgery simulation for endoscopic gynaecology.

    Science.gov (United States)

    Székely, G; Bajka, M; Brechbühler, C; Dual, J; Enzler, R; Haller, U; Hug, J; Hutter, R; Ironmonger, N; Kauer, M; Meier, V; Niederer, P; Rhomberg, A; Schmid, P; Schweitzer, G; Thaler, M; Vuskovic, V; Tröster, G

    1999-01-01

    Virtual reality (VR) based surgical simulator systems offer very elegant possibilities to both enrich and enhance traditional education in endoscopic surgery. However, while a wide range of VR simulator systems have been proposed and realized in the past few years, most of these systems are far from able to provide a reasonably realistic surgical environment. We explore the basic approaches to the current limits of realism and ultimately seek to extend these based on our description and analysis of the most important components of a VR-based endoscopic simulator. The feasibility of the proposed techniques is demonstrated on a first modular prototype system implementing the basic algorithms for VR-training in gynaecologic laparoscopy.

  6. CT analysis of 333 cases of congenital malformations of the external and middle ear

    International Nuclear Information System (INIS)

    Zou Xin; Li Qiang; Wang Zhenchang; Xian Junfang; Lan Baosen

    1997-01-01

    To analyze the different CT findings of congenital malformations of the external and middle ear, 333 cases including 404 ears with external and middle ear malformations diagnosed by high resolution CT (HRCT) were analysed according to the location and type of the malformation. In 404 ears, there were 364 ears with atresia of external auditory meatus, 40 ears with stenosis of external auditory meatus, 377 ears with malformation of the ossicles, 382 ears with stenosis of tympanum and 333 ears with anterior position of the mastoid segment of the facial canal. HRCT can show the location and type of external and middle ear malformation and provide valuable information for surgery

  7. Blended learning in surgery using the Inmedea Simulator.

    Science.gov (United States)

    Funke, Katrin; Bonrath, Esther; Mardin, Wolf Arif; Becker, Jan Carl; Haier, Joerg; Senninger, Norbert; Vowinkel, Thorsten; Hoelzen, Jens Peter; Mees, Soeren Torge

    2013-02-01

    Recently, medical education in surgery has experienced several modifications. We have implemented a blended learning module in our teaching curriculum to evaluate its effectiveness, applicability, and acceptance in surgical education. In this prospective study, the traditional face-to-face learning of our teaching curriculum for fourth-year medical students (n = 116) was augmented by the Inmedea Simulator, a web-based E-learning system, with six virtual patient cases. Student results were documented by the system and learning success was determined by comparing patient cases with comparable diseases (second and sixth case). The acceptance among the students was evaluated with a questionnaire. After using the Inmedea Simulator, correct diagnoses were found significantly (P blended learning (score 2.5 ± 1.2) to conventional teaching. The blended learning approach using the Inmedea Simulator was highly appreciated by our medical students and resulted in a significant learning success. Blended learning appears to be a suitable tool to complement traditional teaching in surgery.

  8. Residents' response to bleeding during a simulated robotic surgery task.

    Science.gov (United States)

    Walker, Jessica L; Nathwani, Jay N; Mohamadipanah, Hossein; Laufer, Shlomi; Jocewicz, Frank F; Gwillim, Eran; Pugh, Carla M

    2017-12-01

    The aim of this study was to assess performance measurement validity of our newly developed robotic surgery task trainer. We hypothesized that residents would exhibit wide variations in their intercohort performance as well as a measurable difference compared to surgeons in fellowship training. Our laboratory synthesized a model of a pelvic tumor that simulates unexpected bleeding. Surgical residents and fellows of varying specialties completed a demographic survey and were allowed 20 minutes to resect the tumor using the da Vinci robot and achieve hemostasis. At a standardized event in the simulation, venous bleeding began, and participants attempted hemostasis using suture ligation. A motion tracking system, using electromagnetic sensors, recorded participants' hand movements. A postparticipation Likert scale survey evaluated participants' assessment of the model's realism and usefulness. Three of the seven residents (postgraduate year 2-5), and the fellow successfully resected the tumor in the allotted time. Residents showed high variability in performance and blood loss (125-700 mL) both within their cohort and compared to the fellow (150 mL blood). All participants rated the model as having high realism and utility for trainees. The results support that our bleeding pelvic tumor simulator has the ability to discriminate resident performance in robotic surgery. The combination of motion, decision-making, and blood loss metrics offers a multilevel performance assessment, analyzing both technical and decision-making abilities. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Design-Based Comparison of Spine Surgery Simulators: Optimizing Educational Features of Surgical Simulators.

    Science.gov (United States)

    Ryu, Won Hyung A; Mostafa, Ahmed E; Dharampal, Navjit; Sharlin, Ehud; Kopp, Gail; Jacobs, W Bradley; Hurlbert, R John; Chan, Sonny; Sutherland, Garnette R

    2017-10-01

    Simulation-based education has made its entry into surgical residency training, particularly as an adjunct to hands-on clinical experience. However, one of the ongoing challenges to wide adoption is the capacity of simulators to incorporate educational features required for effective learning. The aim of this study was to identify strengths and limitations of spine simulators to characterize design elements that are essential in enhancing resident education. We performed a mixed qualitative and quantitative cohort study with a focused survey and interviews of stakeholders in spine surgery pertaining to their experiences on 3 spine simulators. Ten participants were recruited spanning all levels of training and expertise until qualitative analysis reached saturation of themes. Participants were asked to perform lumbar pedicle screw insertion on 3 simulators. Afterward, a 10-item survey was administrated and a focused interview was conducted to explore topics pertaining to the design features of the simulators. Overall impressions of the simulators were positive with regards to their educational benefit, but our qualitative analysis revealed differing strengths and limitations. Main design strengths of the computer-based simulators were incorporation of procedural guidance and provision of performance feedback. The synthetic model excelled in achieving more realistic haptic feedback and incorporating use of actual surgical tools. Stakeholders from trainees to experts acknowledge the growing role of simulation-based education in spine surgery. However, different simulation modalities have varying design elements that augment learning in distinct ways. Characterization of these design characteristics will allow for standardization of simulation curricula in spinal surgery, optimizing educational benefit. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Monitored anaesthesia care – Comparison of nalbuphine/dexmedetomidine versus nalbuphine/propofol for middle ear surgeries: A double-blind randomised trial

    Directory of Open Access Journals (Sweden)

    Srinivasa Rao Nallam

    2017-01-01

    Full Text Available Background and Aims: Middle ear surgeries (MESs are usually performed under sedation with local anaesthesia and can be well tolerated by the patient with minimal discomfort. In the present study, we compare the effect of nalbuphine/dexmedetomidine combination with nalbuphine/propofol on sedation and analgesia in monitored anaesthesia care. Methods: One hundred adult patients undergoing MESs under monitored anaesthesia care (MAC were randomly allocated into two groups. All patients in both groups received injection nalbuphine 50 μg/kg intravenously (IV. Group D received a bolus dose of injection dexmedetomidine 1 μg/kg IV over 10 min followed by an infusion started at 0.4 μg/kg/h IV. Group P received a bolus dose of injection propofol 0.75 mg/kg followed by an infusion started at 0.025 mg/kg/min IV. Sedation was titrated to Ramsay Sedation Score (RSS of 3. Patient's mean arterial pressure, heart rate, saturation peripheral pulse and need for intraoperative rescue sedation/analgesia were recorded and compared. The data analysis was carried out with Z test and Chi-square test. Results: Mean RSS was significantly more in Group D (4.24 ± 1.54 as compared to Group P (2.58 ± 0.95. Overall VAS score was also significantly less in Group D (3.5 ± 1.7 than in Group P (5.4 ± 1.8. In total, 16 patients (32% in Group D had hypotension whereas 7 patients (14% only in Group P had hypotension. Conclusion: Nalbuphine/dexmedetomidine combination is superior to nalbuphine/propofol in producing sedation and decreasing VAS in patients undergoing MESs under MAC. Better surgeon and patient satisfaction were observed with nalbuphine/dexmedetomidine. Haemodynamics need to be closely monitored.

  11. Microbiomes of the normal middle ear and ears with chronic otitis media.

    Science.gov (United States)

    Minami, Shujiro B; Mutai, Hideki; Suzuki, Tomoko; Horii, Arata; Oishi, Naoki; Wasano, Koichiro; Katsura, Motoyasu; Tanaka, Fujinobu; Takiguchi, Tetsuya; Fujii, Masato; Kaga, Kimitaka

    2017-10-01

    The aim of this study was to profile and compare the middle ear microbiomes of human subjects with and without chronic otitis media. Prospective multicenter cohort study. All consecutive patients undergoing tympanoplasty surgery for chronic otitis media or ear surgery for conditions other than otitis media were recruited. Sterile swab samples were collected from the middle ear mucosa during surgery. The variable region 4 of the 16S rRNA gene in each sample were amplified using region-specific primers adapted for the Illumina MiSeq sequencer (Illumina, CA, USA)). The sequences were subjected to local blast and classified using Metagenome@KIN (World Fusion, Tokyo, Japan). In total, 155 participants were recruited from seven medical centers. Of these, 88 and 67 had chronic otitis media and normal middle ears, respectively. The most abundant bacterial phyla on the mucosal surfaces of the normal middle ears were Proteobacteria, followed by Actinobacteria, Firmicutes, and Bacteroidetes. The children and adults with normal middle ears differed significantly in terms of middle ear microbiomes. Subjects with chronic otitis media without active inflammation (dry ear) had similar middle ear microbiomes as the normal middle ears group. Subjects with chronic otitis media with active inflammation (wet ear) had a lower prevalence of Proteobacteria and a higher prevalence of Firmicutes than the normal middle ears. The human middle ear is inhabited by more diverse microbial communities than was previously thought. Alteration of the middle ear microbiome may contribute to the pathogenesis of chronic otitis media with active inflammation. 2b. Laryngoscope, 127:E371-E377, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Lung surgery assisted by multidetector-row computed tomographic simulation

    International Nuclear Information System (INIS)

    Oizumi, Hiroyuki; Endoh, Makoto; Ota, Hiroshi; Takeda, Shinichi; Suzuki, Jun; Fukaya, Ken; Chiba, Masato; Sadahiro, Mitsuaki

    2009-01-01

    We describe the benefits of lung resection simulation using multidetector computed tomography (MDCT). Since 2004, the 1.0-mm slice digital imaging and communications in medicine (DICOM) server has been used for storing data obtained using 64-row MDCT. We observed that an abnormality could not be visualized from the pleural surface in 10 nodules of 18 lesions undergoing wedge lung resection. These 10 nodules were resected through simulation using a three-dimensional (3D) volume-rendering method by considering parameters such as the position, depth, or distance from the interlobar abnormalities, etc., without the need for any marking methods. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. However, in the initial 10 patients of this series, the preoperative identification of 2 small arterial branches was unsuccessful when this method was used. Therefore, it is important to carefully examine the original data in all 3 views, id est (i.e.), axial, sagittal, and coronal views. The visualization of venous branches in affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. We divided the cases of thoracoscopic lung segmentectomy into 3 groups (level 1: simple, level 2: intermediate, and level 3: complex) on the basis of the technical complexity. Only level 1 segmentectomies were performed without MDCT simulation. Further, level 2 and 3 segmentectomies could be successfully performed because of the introduction of MDCT simulation in 25 of 35 patients. Thus, this simulation technique may be useful during a thoracoscopic procedure for lung surgery. (author)

  13. Fundamentals of force feedback and application to a surgery simulator.

    Science.gov (United States)

    Maass, Heiko; Chantier, Benjamin B A; Cakmak, Hueseyin K; Trantakis, Christos; Kuehnapfel, Uwe G

    2003-01-01

    Force feedback increases the effectiveness of virtual-reality surgery training systems. An overview of the fundamentals of applying force feedback is presented. An impedance control technique and data processing methods for stability preservation are illustrated. A flexible interface for general force-feedback applications has been developed. This interface is capable of controlling several different force-feedback hardware systems, including the SensAble PHANTOM, the Laparoscopic Impulse Engines from Immersion, and the VS-One virtual endoscopic surgery trainer. The findings are evaluated using the main simulation system, KISMET, and the modeling tools KISMO and VESUV. Within the scope of a cooperative project called HapticIO (funded by the German Ministry of Education and Research [BMBF]), new haptic devices have been designed for virtual neuroendoscopy and laparoscopy. The concept and implementations presented in this paper have been found to be flexible, stable and suitable for universal use. The impedance method, combined with the open-loop feed-forward control technique, is well suited and appropriate for the task.

  14. Animal models in plastic and reconstructive surgery simulation-a review.

    Science.gov (United States)

    Loh, Charles Yuen Yung; Wang, Aline Yen Ling; Tiong, Vincent Tze Yang; Athanassopoulos, Thanassi; Loh, Meiling; Lim, Philip; Kao, Huang-Kai

    2018-01-01

    The use of live and cadaveric animal models in surgical training is well established as a means of teaching and improving surgical skill in a controlled setting. We aim to review, evaluate, and summarize the models published in the literature that are applicable to Plastic Surgery training. A PubMed search for keywords relating to animal models in Plastic Surgery and the associated procedures was conducted. Animal models that had cross over between specialties such as microsurgery with Neurosurgery and pinnaplasty with ear, nose, and throat surgery were included as they were deemed to be relevant to our training curriculum. A level of evidence and recommendation assessment was then given to each surgical model. Our review found animal models applicable to plastic surgery training in four major categories namely-microsurgery training, flap raising, facial surgery, and hand surgery. Twenty-four separate articles described various methods of practicing microsurgical techniques on different types of animals. Fourteen different articles each described various methods of conducting flap-based procedures which consisted of either local or perforator flap dissection. Eight articles described different models for practicing hand surgery techniques. Finally, eight articles described animal models that were used for head and neck procedures. A comprehensive summary of animal models related to plastic surgery training has been compiled. Cadaveric animal models provide a readily available introduction to many procedures and ought to be used instead of live models when feasible. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Graphic and haptic simulation system for virtual laparoscopic rectum surgery.

    Science.gov (United States)

    Pan, Jun J; Chang, Jian; Yang, Xiaosong; Zhang, Jian J; Qureshi, Tahseen; Howell, Robert; Hickish, Tamas

    2011-09-01

    Medical simulators with vision and haptic feedback techniques offer a cost-effective and efficient alternative to the traditional medical trainings. They have been used to train doctors in many specialties of medicine, allowing tasks to be practised in a safe and repetitive manner. This paper describes a virtual-reality (VR) system which will help to influence surgeons' learning curves in the technically challenging field of laparoscopic surgery of the rectum. Data from MRI of the rectum and real operation videos are used to construct the virtual models. A haptic force filter based on radial basis functions is designed to offer realistic and smooth force feedback. To handle collision detection efficiently, a hybrid model is presented to compute the deformation of intestines. Finally, a real-time cutting technique based on mesh is employed to represent the incision operation. Despite numerous research efforts, fast and realistic solutions of soft tissues with large deformation, such as intestines, prove extremely challenging. This paper introduces our latest contribution to this endeavour. With this system, the user can haptically operate with the virtual rectum and simultaneously watch the soft tissue deformation. Our system has been tested by colorectal surgeons who believe that the simulated tactile and visual feedbacks are realistic. It could replace the traditional training process and effectively transfer surgical skills to novices. Copyright © 2011 John Wiley & Sons, Ltd.

  16. Effect of music on surgical skill during simulated intraocular surgery.

    Science.gov (United States)

    Kyrillos, Ralph; Caissie, Mathieu

    2017-12-01

    To evaluate the effect of Mozart music compared to silence on anterior segment surgical skill in the context of simulated intraocular surgery. Prospective stratified and randomized noninferiority trial. Fourteen ophthalmologists and 12 residents in ophthalmology. All participants were asked to perform 4 sets of predetermined tasks on the EyeSI surgical simulator (VRmagic, Mannheim, Germany). The participants completed 1 Capsulorhexis task and 1 Anti-Tremor task during 3 separate visits. The first 2 sets determined the basic level on day 1. Then, the participants were stratified by surgical experience and randomized to be exposed to music (Mozart sonata for 2 pianos in D-K448) during either the third or the fourth set of tasks (day 2 or 3). Surgical skill was evaluated using the parameters recorded by the simulator such as "Total score" and "Time" for both tasks and task-specific parameters such as "Out of tolerance percentage" for the Anti-Tremor task and "Deviation of rhexis radius from 2.5 mm," "Roundness," and "Centering" for the Capsulorhexis task. The data were analyzed using the Wilcoxon signed-rank test. No statistically significant differences were noted between exposure and nonexposure for all the Anti-Tremor task parameters as well as most parameters for the Capsulorhexis task. Two parameters for the Capsulorhexis task showed a strong trend for improvement with exposure to music ("Total score" +23.3%, p = 0.025; "Roundness" +33.0%, p = 0.037). Exposure to music did not negatively impact surgical skills. Moreover, a trend for improvement was shown while listening to Mozart music. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  17. Step-based cognitive virtual surgery simulation: an innovative approach to surgical education.

    Science.gov (United States)

    Oliker, Aaron; Napier, Zachary; Deluccia, Nicolette; Qualter, John; Sculli, Frank; Smith, Brandon; Stern, Carrie; Flores, Roberto; Hazen, Alexes; McCarthy, Joseph

    2012-01-01

    BioDigital Systems, LLC in collaboration with New York University Langone Medical Center Department of Reconstructive Plastic Surgery has created a complex, real-time, step-based simulation platform for plastic surgery education. These simulators combine live surgical footage, interactive 3D visualization, text labels, and voiceover as well as a high-yield, expert-approved testing mode to create a comprehensive virtual educational environment for the plastic surgery resident or physician.

  18. Development of the McGill simulator for endoscopic sinus surgery: a new high-fidelity virtual reality simulator for endoscopic sinus surgery.

    Science.gov (United States)

    Varshney, Rickul; Frenkiel, Saul; Nguyen, Lily H P; Young, Meredith; Del Maestro, Rolando; Zeitouni, Anthony; Tewfik, Marc A

    2014-01-01

    The technical challenges of endoscopic sinus surgery (ESS) and the high risk of complications support the development of alternative modalities to train residents in these procedures. Virtual reality simulation is becoming a useful tool for training the skills necessary for minimally invasive surgery; however, there are currently no ESS virtual reality simulators available with valid evidence supporting their use in resident education. Our aim was to develop a new rhinology simulator, as well as to define potential performance metrics for trainee assessment. The McGill simulator for endoscopic sinus surgery (MSESS), a new sinus surgery virtual reality simulator with haptic feedback, was developed (a collaboration between the McGill University Department of Otolaryngology-Head and Neck Surgery, the Montreal Neurologic Institute Simulation Lab, and the National Research Council of Canada). A panel of experts in education, performance assessment, rhinology, and skull base surgery convened to identify core technical abilities that would need to be taught by the simulator, as well as performance metrics to be developed and captured. The MSESS allows the user to perform basic sinus surgery skills, such as an ethmoidectomy and sphenoidotomy, through the use of endoscopic tools in a virtual nasal model. The performance metrics were developed by an expert panel and include measurements of safety, quality, and efficiency of the procedure. The MSESS incorporates novel technological advancements to create a realistic platform for trainees. To our knowledge, this is the first simulator to combine novel tools such as the endonasal wash and elaborate anatomic deformity with advanced performance metrics for ESS.

  19. Surgical robot setup simulation with consistent kinematics and haptics for abdominal surgery.

    Science.gov (United States)

    Hayashibe, Mitsuhiro; Suzuki, Naoki; Hattori, Asaki; Suzuki, Shigeyuki; Konishi, Kozo; Kakeji, Yoshihiro; Hashizume, Makoto

    2005-01-01

    Preoperative simulation and planning of surgical robot setup should accompany advanced robotic surgery if their advantages are to be further pursued. Feedback from the planning system will plays an essential role in computer-aided robotic surgery in addition to preoperative detailed geometric information from patient CT/MRI images. Surgical robot setup simulation systems for appropriate trocar site placement have been developed especially for abdominal surgery. The motion of the surgical robot can be simulated and rehearsed with kinematic constraints at the trocar site, and the inverse-kinematics of the robot. Results from simulation using clinical patient data verify the effectiveness of the proposed system.

  20. Play it by Ear

    DEFF Research Database (Denmark)

    Kammersgaard, Nikolaj Peter Iversen; Kvist, Søren Helstrup; Thaysen, Jesper

    2014-01-01

    The first antenna for ear-to-ear communication with a standard Bluetooth chip has the potential to improve hearing aid technology.......The first antenna for ear-to-ear communication with a standard Bluetooth chip has the potential to improve hearing aid technology....

  1. Student perception of two different simulation techniques in oral and maxillofacial surgery undergraduate training.

    Science.gov (United States)

    Lund, Bodil; Fors, Uno; Sejersen, Ronny; Sallnäs, Eva-Lotta; Rosén, Annika

    2011-10-12

    Yearly surveys among the undergraduate students in oral and maxillofacial surgery at Karolinska Institutet have conveyed a wish for increased clinical training, and in particular, in surgical removal of mandibular third molars. Due to lack of resources, this kind of clinical supervision has so far not been possible to implement. One possible solution to this problem might be to introduce simulation into the curriculum. The purpose of this study was to investigate undergraduate students' perception of two different simulation methods for practicing clinical reasoning skills and technical skills in oral and maxillofacial surgery. Forty-seven students participating in the oral and maxillofacial surgery course at Karolinska Institutet during their final year were included. Three different oral surgery patient cases were created in a Virtual Patient (VP) Simulation system (Web-SP) and used for training clinical reasoning. A mandibular third molar surgery simulator with tactile feedback, providing hands on training in the bone removal and tooth sectioning in third molar surgery, was also tested. A seminar was performed using the combination of these two simulators where students' perception of the two different simulation methods was assessed by means of a questionnaire. The response rate was 91.5% (43/47). The students were positive to the VP cases, although they rated their possible improvement of clinical reasoning skills as moderate. The students' perception of improved technical skills after training in the mandibular third molar surgery simulator was rated high. The majority of the students agreed that both simulation techniques should be included in the curriculum and strongly agreed that it was a good idea to use the two simulators in concert. The importance of feedback from the senior experts during simulator training was emphasised. The two tested simulation methods were well accepted and most students agreed that the future curriculum would benefit from

  2. Imaging of the postoperative middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Marc T. [Department of Medical Imaging, Fondation Ophtalmologique Adolphe de Rothschild, 25 rue Manin, 75940, Paris (France); Ayache, Denis [Department of Otorhinolaryngology, Fondation Ophtalmologique Adolphe de Rothschild, Paris (France)

    2004-03-01

    The aim of this article is twofold: (a) to present the principles and the indications of surgical treatment of middle ear pathologies; and (b) to review the imaging findings after middle ear surgery, including the normal postoperative aspects and imaging findings in patients presenting with unsatisfactory surgical results or with suspicion of postoperative complications. This review is intentionally restricted to the most common diseases involving the middle ear: chronic otitis media and otosclerosis. In these specific fields of interest, CT and MR imaging play a very important role in the postoperative follow-up and in the work-up of surgical failures and complications. (orig.)

  3. [Guided maxillofacial surgery: Simulation and surgery aided by stereolithographic guides and custom-made miniplates.

    Science.gov (United States)

    Philippe, B

    2013-08-05

    We present a new model of guided surgery, exclusively using computer assistance, from the preoperative planning of osteotomies to the actual surgery with the aid of stereolithographic cutting guides and osteosynthetic miniplates designed and made preoperatively, using custom-made titanium miniplates thanks to direct metal laser sintering. We describe the principles that guide the designing and industrial manufacturing of this new type of osteosynthesis miniplates. The surgical procedure is described step-by-step using several representative cases of dento-maxillofacial dysmorphosis. The encouraging short-term results demonstrate the wide range of application of this new technology for cranio-maxillofacial surgery, whatever the type of osteotomy performed, and for plastic reconstructive surgery. Copyright © 2013. Published by Elsevier Masson SAS.

  4. [Three-dimensional display simulation of lung surgery using "active shutter glasses"].

    Science.gov (United States)

    Onuki, Takamasa; Kanzaki, Masato; Sakamoto, Kei; Kikkawa, Takuma; Isaka, Tamami; Shimizu, Toshihide; Oyama, Kunihiro; Murasugi, Masahide

    2011-08-01

    We have reported preoperative 3-dimensional (3D) simulation of thoracoscopic lung surgery using self-made software and internet shareware of 3D-modeler. Using "active shutter glasses", we have tried the "3D display simulation" of lung surgery. 3D display was more effective to grasp clear 3D interrelation between the bronchii and pulmonary vascular system than those in images of currently in use with the same information volume.

  5. A review of simulation platforms in surgery of the temporal bone.

    Science.gov (United States)

    Bhutta, M F

    2016-10-01

    Surgery of the temporal bone is a high-risk activity in an anatomically complex area. Simulation enables rehearsal of such surgery. The traditional simulation platform is the cadaveric temporal bone, but in recent years other simulation platforms have been created, including plastic and virtual reality platforms. To undertake a review of simulation platforms for temporal bone surgery, specifically assessing their educational value in terms of validity and in enabling transition to surgery. Systematic qualitative review. Search of the Pubmed, CINAHL, BEI and ERIC databases. Assessment of reported outcomes in terms of educational value. A total of 49 articles were included, covering cadaveric, animal, plastic and virtual simulation platforms. Cadaveric simulation is highly rated as an educational tool, but there may be a ceiling effect on educational outcomes after drilling 8-10 temporal bones. Animal models show significant anatomical variation from man. Plastic temporal bone models offer much potential, but at present lack sufficient anatomical or haptic validity. Similarly, virtual reality platforms lack sufficient anatomical or haptic validity, but with technological improvements they are advancing rapidly. At present, cadaveric simulation remains the best platform for training in temporal bone surgery. Technological advances enabling improved materials or modelling mean that in the future plastic or virtual platforms may become comparable to cadaveric platforms, and also offer additional functionality including patient-specific simulation from CT data. © 2015 John Wiley & Sons Ltd.

  6. A review of virtual reality based training simulators for orthopaedic surgery.

    Science.gov (United States)

    Vaughan, Neil; Dubey, Venketesh N; Wainwright, Thomas W; Middleton, Robert G

    2016-02-01

    This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In total 11 hip replacements pre-operative planning tools were analysed, plus 9 hip trauma fracture training simulators. Additionally 9 knee arthroscopy simulators and 8 other orthopaedic simulators were included for comparison. The findings are that for orthopaedic surgery simulators in general, there is increasing use of patient-specific virtual models which reduce the learning curve. Modelling is also being used for patient-specific implant design and manufacture. Simulators are being increasingly validated for assessment as well as training. There are very few training simulators available for hip replacement, yet more advanced virtual reality is being used for other procedures such as hip trauma and drilling. Training simulators for hip replacement and orthopaedic surgery in general lag behind other surgical procedures for which virtual reality has become more common. Further developments are required to bring hip replacement training simulation up to date with other procedures. This suggests there is a gap in the market for a new high fidelity hip replacement and resurfacing training simulator. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. A review of virtual reality based training simulators for orthopaedic surgery

    OpenAIRE

    Vaughan, Neil; Dubey, Venketesh N.; Wainwright, Tom; Middleton, Robert

    2015-01-01

    This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In total 11 total hip replacement pre-operative planning tools were analysed, plus 9 hip trauma fracture tr...

  8. Environment for Auditory Research Facility (EAR)

    Data.gov (United States)

    Federal Laboratory Consortium — EAR is an auditory perception and communication research center enabling state-of-the-art simulation of various indoor and outdoor acoustic environments. The heart...

  9. Ear Infection and Vaccines

    Science.gov (United States)

    ... an ENT Doctor Near You Ear Infection and Vaccines Ear Infection and Vaccines Patient Health Information News ... or may need reinsertion over time. What about vaccines? A vaccine is a preparation administered to stimulate ...

  10. Swimmer's Ear (For Parents)

    Science.gov (United States)

    ... Development Infections Diseases & Conditions Pregnancy & Baby Nutrition & Fitness Emotions & Behavior School & Family Life First Aid & Safety Doctors & ... can lead to an infection. Dry skin or eczema , scratching the ear canal, vigorous ear cleaning with ...

  11. Taking Care of Your Ears

    Science.gov (United States)

    ... Audiologist Perforated Eardrum What's Hearing Loss? Can Loud Music Hurt My Ears? What Is an Ear Infection? Swimmer's Ear Your Ears What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  12. Current status of validation for robotic surgery simulators - a systematic review.

    Science.gov (United States)

    Abboudi, Hamid; Khan, Mohammed S; Aboumarzouk, Omar; Guru, Khurshid A; Challacombe, Ben; Dasgupta, Prokar; Ahmed, Kamran

    2013-02-01

    To analyse studies validating the effectiveness of robotic surgery simulators. The MEDLINE(®), EMBASE(®) and PsycINFO(®) databases were systematically searched until September 2011. References from retrieved articles were reviewed to broaden the search. The simulator name, training tasks, participant level, training duration and evaluation scoring were extracted from each study. We also extracted data on feasibility, validity, cost-effectiveness, reliability and educational impact. We identified 19 studies investigating simulation options in robotic surgery. There are five different robotic surgery simulation platforms available on the market. In all, 11 studies sought opinion and compared performance between two different groups; 'expert' and 'novice'. Experts ranged in experience from 21-2200 robotic cases. The novice groups consisted of participants with no prior experience on a robotic platform and were often medical students or junior doctors. The Mimic dV-Trainer(®), ProMIS(®), SimSurgery Educational Platform(®) (SEP) and Intuitive systems have shown face, content and construct validity. The Robotic Surgical SimulatorTM system has only been face and content validated. All of the simulators except SEP have shown educational impact. Feasibility and cost-effectiveness of simulation systems was not evaluated in any trial. Virtual reality simulators were shown to be effective training tools for junior trainees. Simulation training holds the greatest potential to be used as an adjunct to traditional training methods to equip the next generation of robotic surgeons with the skills required to operate safely. However, current simulation models have only been validated in small studies. There is no evidence to suggest one type of simulator provides more effective training than any other. More research is needed to validate simulated environments further and investigate the effectiveness of animal and cadaveric training in robotic surgery. © 2012 BJU

  13. Real-time volumetric deformable models for surgery simulation using finite elements and condensation

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten; Cotin, S.

    1996-01-01

    This paper discusses the application of SD solid volumetric Finite Element models to surgery simulation. In particular it introduces three new ideas for solving the problem of achieving real-time performance for these models. The simulation system we have developed is described and we demonstrate...

  14. Development of a Virtual Reality Simulator for Natural Orifice Translumenal Endoscopic Surgery (NOTES) Cholecystectomy Procedure.

    Science.gov (United States)

    Ahn, Woojin; Dargar, Saurabh; Halic, Tansel; Lee, Jason; Li, Baichun; Pan, Junjun; Sankaranarayanan, Ganesh; Roberts, Kurt; De, Suvranu

    2014-01-01

    The first virtual-reality-based simulator for Natural Orifice Translumenal Endoscopic Surgery (NOTES) is developed called the Virtual Translumenal Endoscopic Surgery Trainer (VTESTTM). VTESTTM aims to simulate hybrid NOTES cholecystectomy procedure using a rigid scope inserted through the vaginal port. The hardware interface is designed for accurate motion tracking of the scope and laparoscopic instruments to reproduce the unique hand-eye coordination. The haptic-enabled multimodal interactive simulation includes exposing the Calot's triangle and detaching the gall bladder while performing electrosurgery. The developed VTESTTM was demonstrated and validated at NOSCAR 2013.

  15. Current state of virtual reality simulation in robotic surgery training: a review.

    Science.gov (United States)

    Bric, Justin D; Lumbard, Derek C; Frelich, Matthew J; Gould, Jon C

    2016-06-01

    Worldwide, the annual number of robotic surgical procedures continues to increase. Robotic surgical skills are unique from those used in either open or laparoscopic surgery. The acquisition of a basic robotic surgical skill set may be best accomplished in the simulation laboratory. We sought to review the current literature pertaining to the use of virtual reality (VR) simulation in the acquisition of robotic surgical skills on the da Vinci Surgical System. A PubMed search was conducted between December 2014 and January 2015 utilizing the following keywords: virtual reality, robotic surgery, da Vinci, da Vinci skills simulator, SimSurgery Educational Platform, Mimic dV-Trainer, and Robotic Surgery Simulator. Articles were included if they were published between 2007 and 2015, utilized VR simulation for the da Vinci Surgical System, and utilized a commercially available VR platform. The initial search criteria returned 227 published articles. After all inclusion and exclusion criteria were applied, a total of 47 peer-reviewed manuscripts were included in the final review. There are many benefits to utilizing VR simulation for robotic skills acquisition. Four commercially available simulators have been demonstrated to be capable of assessing robotic skill. Three of the four simulators demonstrate the ability of a VR training curriculum to improve basic robotic skills, with proficiency-based training being the most effective training style. The skills obtained on a VR training curriculum are comparable with those obtained on dry laboratory simulation. The future of VR simulation includes utilization in assessment for re-credentialing purposes, advanced procedural-based training, and as a warm-up tool prior to surgery.

  16. Development and implementation of a clinical pathway approach to simulation-based training for foregut surgery.

    Science.gov (United States)

    Miyasaka, Kiyoyuki W; Buchholz, Joseph; LaMarra, Denise; Karakousis, Giorgos C; Aggarwal, Rajesh

    2015-01-01

    Contemporary demands on resident education call for integration of simulation. We designed and implemented a simulation-based curriculum for Post Graduate Year 1 surgery residents to teach technical and nontechnical skills within a clinical pathway approach for a foregut surgery patient, from outpatient visit through surgery and postoperative follow-up. The 3-day curriculum for groups of 6 residents comprises a combination of standardized patient encounters, didactic sessions, and hands-on training. The curriculum is underpinned by a summative simulation "pathway" repeated on days 1 and 3. The "pathway" is a series of simulated preoperative, intraoperative, and postoperative encounters in following up a single patient through a disease process. The resident sees a standardized patient in the clinic presenting with distal gastric cancer and then enters an operating room to perform a gastrojejunostomy on a porcine tissue model. Finally, the resident engages in a simulated postoperative visit. All encounters are rated by faculty members and the residents themselves, using standardized assessment forms endorsed by the American Board of Surgery. A total of 18 first-year residents underwent this curriculum. Faculty ratings of overall operative performance significantly improved following the 3-day module. Ratings of preoperative and postoperative performance were not significantly changed in 3 days. Resident self-ratings significantly improved for all encounters assessed, as did reported confidence in meeting the defined learning objectives. Conventional surgical simulation training focuses on technical skills in isolation. Our novel "pathway" curriculum targets an important gap in training methodologies by placing both technical and nontechnical skills in their clinical context as part of managing a surgical patient. Results indicate consistent improvements in assessments of performance as well as confidence and support its continued usage to educate surgery residents

  17. Energy consumption during simulated minimal access surgery with and without using an armrest.

    Science.gov (United States)

    Jafri, Mansoor; Brown, Stuart; Arnold, Graham; Abboud, Rami; Wang, Weijie

    2013-03-01

    Minimal access surgery (MAS) can be a lengthy procedure when compared to open surgery and therefore surgeon fatigue becomes an important issue and surgeons may expose themselves to chronic injuries and making errors. There have been few studies on this topic and they have used only questionnaires and electromyography rather than direct measurement of energy expenditure (EE). The aim of this study was to investigate whether the use of an armrest could reduce the EE of surgeons during MAS. Sixteen surgeons performed simulated MAS with and without using an armrest. They were required to perform the time-consuming task of using scissors to cut a rubber glove through its top layer in a triangular fashion with the help of a laparoscopic camera. Energy consumptions were measured using the Oxycon Mobile system during all the procedures. Error rate and duration time for simulated surgery were recorded. After performing the simulated surgery, subjects scored how comfortable they felt using the armrest. It was found that O(2) uptake (VO(2)) was 5 % less when surgeons used the armrest. The error rate when performing the procedure with the armrest was 35 % compared with 42.29 % without the armrest. Additionally, comfort levels with the armrest were higher than without the armrest. 75 % of surgeons indicated a preference for using the armrest during the simulated surgery. The armrest provides support for surgeons and cuts energy consumption during simulated MAS.

  18. A haptic interface for virtual simulation of endoscopic surgery.

    Science.gov (United States)

    Rosenberg, L B; Stredney, D

    1996-01-01

    Virtual reality can be described as a convincingly realistic and naturally interactive simulation in which the user is given a first person illusion of being immersed within a computer generated environment While virtual reality systems offer great potential to reduce the cost and increase the quality of medical training, many technical challenges must be overcome before such simulation platforms offer effective alternatives to more traditional training means. A primary challenge in developing effective virtual reality systems is designing the human interface hardware which allows rich sensory information to be presented to users in natural ways. When simulating a given manual procedure, task specific human interface requirements dictate task specific human interface hardware. The following paper explores the design of human interface hardware that satisfies the task specific requirements of virtual reality simulation of Endoscopic surgical procedures. Design parameters were derived through direct cadaver studies and interviews with surgeons. Final hardware design is presented.

  19. Anthropometric growth study of the ear in a Chinese population.

    Science.gov (United States)

    Zhao, Shichun; Li, Dianguo; Liu, Zhenzhong; Wang, Yibiao; Liu, Lei; Jiang, Duyin; Pan, Bo

    2018-04-01

    A large number of anthropometric studies of the auricle have been reported in different nations, but little data were available in the Chinese population. The aim of this study was to analyze growth changes in the ear by measuring the width and length of ears in a Chinese population. A total of 480 participants were enrolled and classified into 1-, 3-, 5-, 7-, 9-, 12-, 14-, and 18-year groups (half were boys and half were girls in each group). Ear length, ear width, body weight, and body length were measured and recorded; ear index was calculated according to ear length and ear width. The growth of auricle and differences between genders were analyzed. Growth of ear in relation to body height and weight and the degree of emphasis on the length and width of the auricle were also analyzed. Ear length and width increased with age. Ear length achieved its mature size in both 14-year-old males and females. Ear width reached its mature size in males at 7 years and in females at 5 years. Different trends of ear index were shown between males and females. People in this population paid more attention to the length than the width of the auricle. The data indicated that ear development followed increase in age. There were gender and ethnic difference in the development of ear. These results may have potential implications for the diagnosis of congenital malformations, syndromes, and planning of ear reconstruction surgery. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Virtual reality-based simulators for spine surgery: a systematic review.

    Science.gov (United States)

    Pfandler, Michael; Lazarovici, Marc; Stefan, Philipp; Wucherer, Patrick; Weigl, Matthias

    2017-09-01

    Virtual reality (VR)-based simulators offer numerous benefits and are very useful in assessing and training surgical skills. Virtual reality-based simulators are standard in some surgical subspecialties, but their actual use in spinal surgery remains unclear. Currently, only technical reviews of VR-based simulators are available for spinal surgery. Thus, we performed a systematic review that examined the existing research on VR-based simulators in spinal procedures. We also assessed the quality of current studies evaluating VR-based training in spinal surgery. Moreover, we wanted to provide a guide for future studies evaluating VR-based simulators in this field. This is a systematic review of the current scientific literature regarding VR-based simulation in spinal surgery. Five data sources were systematically searched to identify relevant peer-reviewed articles regarding virtual, mixed, or augmented reality-based simulators in spinal surgery. A qualitative data synthesis was performed with particular attention to evaluation approaches and outcomes. Additionally, all included studies were appraised for their quality using the Medical Education Research Study Quality Instrument (MERSQI) tool. The initial review identified 476 abstracts and 63 full texts were then assessed by two reviewers. Finally, 19 studies that examined simulators for the following procedures were selected: pedicle screw placement, vertebroplasty, posterior cervical laminectomy and foraminotomy, lumbar puncture, facet joint injection, and spinal needle insertion and placement. These studies had a low-to-medium methodological quality with a MERSQI mean score of 11.47 out of 18 (standard deviation=1.81). This review described the current state and applications of VR-based simulator training and assessment approaches in spinal procedures. Limitations, strengths, and future advancements of VR-based simulators for training and assessment in spinal surgery were explored. Higher-quality studies with

  1. Early orthognathic surgery with three-dimensional image simulation during presurgical orthodontics in adults.

    Science.gov (United States)

    Kang, Sang-Hoon; Kim, Moon-Key; Park, Sun-Yeon; Lee, Ji-Yeon; Park, Wonse; Lee, Sang-Hwy

    2011-03-01

    To correct dentofacial deformities, three-dimensional skeletal analysis and computerized orthognathic surgery simulation are used to facilitate accurate diagnoses and surgical plans. Computed tomography imaging of dental occlusion can inform three-dimensional facial analyses and orthognathic surgical simulations. Furthermore, three-dimensional laser scans of a cast model of the predetermined postoperative dental occlusion can be used to increase the accuracy of the preoperative surgical simulation. In this study, we prepared cast models of planned postoperative dental occlusions from 12 patients diagnosed with skeletal class III malocclusions with mandibular prognathism and facial asymmetry that had planned to undergo bimaxillary orthognathic surgery during preoperative orthodontic treatment. The data from three-dimensional laser scans of the cast models were used in three-dimensional surgical simulations. Early orthognathic surgeries were performed based on three-dimensional image simulations using the cast images in several presurgical orthodontic states in which teeth alignment, leveling, and space closure were incomplete. After postoperative orthodontic treatments, intraoral examinations revealed that no patient had a posterior open bite or space. The two-dimensional and three-dimensional skeletal analyses showed that no mandibular deviations occurred between the immediate and final postoperative states of orthodontic treatment. These results showed that early orthognathic surgery with three-dimensional computerized simulations based on cast models of predetermined postoperative dental occlusions could provide early correction of facial deformities and improved efficacy of preoperative orthodontic treatment. This approach can reduce the decompensation treatment period of the presurgical orthodontics and contribute to efficient postoperative orthodontic treatments.

  2. Long-term Follow-up Results of Regeneration Process of Fungiform Taste Buds After Severing the Chorda Tympani Nerve During Middle Ear Surgery.

    Science.gov (United States)

    Saito, Takehisa; Ito, Tetsufumi; Ito, Yumi; Manabe, Yasuhiro

    2016-05-01

    To elucidate the regeneration process of fungiform taste buds after severing the chorda tympani nerve (CTN) by confocal laser scanning microscopy in vivo. In 7 consecutive patients whose CTN was severed during tympanoplasty, an average of 10 fungiform papillae in the midlateral region of the tongue were periodically observed, and the number of taste buds was counted until 12 to 24 months after surgery. Gustatory function was assessed by EGM. EGM thresholds showed no response within 1 month after surgery in any patient. All taste buds had disappeared until 13 to 71 days after surgery. Regenerated taste buds were first detected 5 to 8 months after surgery in 5 of the 7 patients. EGM thresholds recovered to their preoperative values in 2 patients. In these 2 patients, the number of regenerated taste buds gradually increased in combination with a recovered taste function. However, a time lag existed between taste bud regeneration and taste function recovery. EGM thresholds did not recover in the other 3 patients with regenerated taste buds, suggesting that these taste buds were immature without gustatory function. The long-term regeneration process of fungiform taste buds could be clarified using confocal laser scanning microscopy. © The Author(s) 2015.

  3. Surgeon Training in Telerobotic Surgery via a Hardware-in-the-Loop Simulator

    Directory of Open Access Journals (Sweden)

    Xiao Li

    2017-01-01

    Full Text Available This work presents a software and hardware framework for a telerobotic surgery safety and motor skill training simulator. The aims are at providing trainees a comprehensive simulator for acquiring essential skills to perform telerobotic surgery. Existing commercial robotic surgery simulators lack features for safety training and optimal motion planning, which are critical factors in ensuring patient safety and efficiency in operation. In this work, we propose a hardware-in-the-loop simulator directly introducing these two features. The proposed simulator is built upon the Raven-II™ open source surgical robot, integrated with a physics engine and a safety hazard injection engine. Also, a Fast Marching Tree-based motion planning algorithm is used to help trainee learn the optimal instrument motion patterns. The main contributions of this work are (1 reproducing safety hazards events, related to da Vinci™ system, reported to the FDA MAUDE database, with a novel haptic feedback strategy to provide feedback to the operator when the underlying dynamics differ from the real robot’s states so that the operator will be aware and can mitigate the negative impact of the safety-critical events, and (2 using motion planner to generate semioptimal path in an interactive robotic surgery training environment.

  4. VIRGY: a virtual reality and force feedback based endoscopic surgery simulator.

    Science.gov (United States)

    Baur, C; Guzzoni, D; Georg, O

    1998-01-01

    This paper describes the VIRGY project at the VRAI Group (Virtual Reality and Active Interface), Swiss Federal Institute of Technology (Lausanne, Switzerland). Since 1994, we have been investigating a variety of virtual-reality based methods for simulating laparoscopic surgery procedures. Our goal is to develop an endoscopic surgical training tool which realistically simulates the interactions between one or more surgical instruments and gastrointestinal organs. To support real-time interaction and manipulation between instruments and organs, we have developed several novel graphic simulation techniques. In particular, we are using live video texturing to achieve dynamic effects such as bleeding or vaporization of fatty tissues. Special texture manipulations allows us to generate pulsing objects while minimizing processor load. Additionally, we have created a new surface deformation algorithm which enables real-time deformations under external constraints. Lastly, we have developed a new 3D object definition which allows us to perform operations such as total or partial object cuttings, as well as to selectively render objects with different levels of detail. To provide realistic physical simulation of the forces and torques on surgical instruments encountered during an operation, we have also designed a new haptic device dedicated to endososcopic surgery constraints. We are using special interpolation and extrapolation techniques to integrate our 25 Hz visual simulation with the 300 Hz feedback required for realistic tactile interaction. The fully VIRGY simulator has been tested by surgeons and the quality of both our visual and haptic simulation has been judged sufficient for training basic surgery gestures.

  5. [Possibilities of computer graphics simulation in orthopedic surgery].

    Science.gov (United States)

    Kessler, P; Wiltfang, J; Teschner, M; Girod, B; Neukam, F W

    2000-11-01

    In addition to standard X-rays, photographic documentation, cephalometric and model analysis, a computer-aided, three-dimensional (3D) simulation system has been developed in close cooperation with the Institute of Communications of the Friedrich-Alexander-Universität Erlangen-Nürnberg. With this simulation system a photorealistic prediction of the expected soft tissue changes can be made. Prerequisites are a 3D reconstruction of the facial skeleton and a 3D laser scan of the face. After data reduction, the two data sets can be matched. Cutting planes enable the transposition of bony segments. The laser scan of the facial surface is combined with the underlying bone via a five-layered soft tissue model to convert bone movements on the soft tissue cover realistically. Further research is necessary to replace the virtual subcutaneous soft tissue model by correct, topographic tissue anatomy.

  6. Non-echoplanar diffusion-weighted MRI in children and adolescents with cholesteatoma: reliability and pitfalls in comparison to middle ear surgery

    International Nuclear Information System (INIS)

    Kalle, Thekla von; Amrhein, Peter; Koitschev, Assen

    2015-01-01

    Currently, there is only limited and contradictory evidence of the role of diffusion-weighted MRI (DW-MRI) in the management of children with cholesteatoma. To provide surgically controlled data that may allow to replace second-look surgery by non-echoplanar DW-MRI in children. Fifty-five children and adolescents with a median age of 8.6 years (2.2-17.7 years) underwent 61 preoperative half-Fourier acquisition single-shot turbo spin-echo (HASTE) DW-MRI of their petrous bone. Surgical interventions followed within 24 h (79%), within 5 months (20%) or at 18 months (1 case). Surgery detected a cholesteatoma or retraction pocket in 41 of 61 cases (67%). In 49 cases (80%), the MR result was confirmed by surgical findings. Two MR findings were false-positive and 10 false-negative (including cholesteatomas <4 mm). HASTE DW-MRI alone had a sensitivity of 76% and a specificity of 90%. The positive predictive value was 94%, the negative predictive value 64%. In combination with preoperative otoscopy, sensitivity was 90% and negative predictive value 82%. DW-MRI correctly detected the majority of lesions but could not reliably exclude small cholesteatomas and empty retraction pockets. We would therefore not generally recommend MR as a substitute for second-look surgery. (orig.)

  7. Non-echoplanar diffusion-weighted MRI in children and adolescents with cholesteatoma: reliability and pitfalls in comparison to middle ear surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kalle, Thekla von [Olgahospital Klinikum Stuttgart, Pediatric Radiology, Radiologisches Institut, Stuttgart (Germany); Amrhein, Peter; Koitschev, Assen [Olgahospital Klinikum Stuttgart, Division of Pediatric Otorhinolaryngology and Otology, Department of Otorhinolaryngology, Stuttgart (Germany)

    2015-07-15

    Currently, there is only limited and contradictory evidence of the role of diffusion-weighted MRI (DW-MRI) in the management of children with cholesteatoma. To provide surgically controlled data that may allow to replace second-look surgery by non-echoplanar DW-MRI in children. Fifty-five children and adolescents with a median age of 8.6 years (2.2-17.7 years) underwent 61 preoperative half-Fourier acquisition single-shot turbo spin-echo (HASTE) DW-MRI of their petrous bone. Surgical interventions followed within 24 h (79%), within 5 months (20%) or at 18 months (1 case). Surgery detected a cholesteatoma or retraction pocket in 41 of 61 cases (67%). In 49 cases (80%), the MR result was confirmed by surgical findings. Two MR findings were false-positive and 10 false-negative (including cholesteatomas <4 mm). HASTE DW-MRI alone had a sensitivity of 76% and a specificity of 90%. The positive predictive value was 94%, the negative predictive value 64%. In combination with preoperative otoscopy, sensitivity was 90% and negative predictive value 82%. DW-MRI correctly detected the majority of lesions but could not reliably exclude small cholesteatomas and empty retraction pockets. We would therefore not generally recommend MR as a substitute for second-look surgery. (orig.)

  8. Hairy ears; Revisited

    Directory of Open Access Journals (Sweden)

    Daifullah Al Aboud

    2014-04-01

    Full Text Available Hair can grow in areas which are not usually hairy in human skin. The Online Mendelian Inheritance in Man (OMIM (http:// www.ncbi.nlm.nih.gov/omimhave some entries in this regards. These include ( %139600 – HAIRY ELBOWS, #605130 – HAIRY ELBOWS, SHORT STATURE, FACIAL DYSMORPHISM, AND DEVELOPMENTAL DELAY, 139630 – HAIRY NOSE TIP, 139500 – HAIRY EARS, and 425500 – HAIRY EARS, Y-LINKED. Hairy ears, (Fig. 1, are uncommon trait and it is rare to see a person with very long hair on the ears.

  9. Using virtual reality simulation to assess competence in video-assisted thoracoscopic surgery (VATS) lobectomy

    DEFF Research Database (Denmark)

    Jensen, Katrine; Bjerrum, Flemming; Hansen, Henrik Jessen

    2017-01-01

    for a virtual reality simulator test of a video-assisted thoracoscopic surgery (VATS) lobectomy of a right upper lobe. METHODS: Participants with varying experience in VATS lobectomy were included. They were familiarized with a virtual reality simulator (LapSim(®)) and introduced to the steps of the procedure...... % false positives) and failed four of the experienced surgeons (29 % false negatives). CONCLUSION: This study is the first to establish validity evidence for a VATS right upper lobe lobectomy virtual reality simulator test. Several simulator metrics demonstrated significant differences between novices...

  10. Predicting Surgery Targets in Temporal Lobe Epilepsy through Structural Connectome Based Simulations.

    Directory of Open Access Journals (Sweden)

    Frances Hutchings

    2015-12-01

    Full Text Available Temporal lobe epilepsy (TLE is a prevalent neurological disorder resulting in disruptive seizures. In the case of drug resistant epilepsy resective surgery is often considered. This is a procedure hampered by unpredictable success rates, with many patients continuing to have seizures even after surgery. In this study we apply a computational model of epilepsy to patient specific structural connectivity derived from diffusion tensor imaging (DTI of 22 individuals with left TLE and 39 healthy controls. We validate the model by examining patient-control differences in simulated seizure onset time and network location. We then investigate the potential of the model for surgery prediction by performing in silico surgical resections, removing nodes from patient networks and comparing seizure likelihood post-surgery to pre-surgery simulations. We find that, first, patients tend to transit from non-epileptic to epileptic states more often than controls in the model. Second, regions in the left hemisphere (particularly within temporal and subcortical regions that are known to be involved in TLE are the most frequent starting points for seizures in patients in the model. In addition, our analysis also implicates regions in the contralateral and frontal locations which may play a role in seizure spreading or surgery resistance. Finally, the model predicts that patient-specific surgery (resection areas chosen on an individual, model-prompted, basis and not following a predefined procedure may lead to better outcomes than the currently used routine clinical procedure. Taken together this work provides a first step towards patient specific computational modelling of epilepsy surgery in order to inform treatment strategies in individuals.

  11. Computer simulation of orthognathic surgery with video imaging

    Science.gov (United States)

    Sader, Robert; Zeilhofer, Hans-Florian U.; Horch, Hans-Henning

    1994-04-01

    Patients with extreme jaw imbalance must often undergo operative corrections. The goal of therapy is to harmonize the stomatognathic system and an aesthetical correction of the face profile. A new procedure will be presented which supports the maxillo-facial surgeon in planning the operation and which also presents the patient the result of the treatment by video images. Once an x-ray has been digitized it is possible to produce individualized cephalometric analyses. Using a ceph on screen, all current orthognathic operations can be simulated, whereby the bony segments are moved according to given parameters, and a new soft tissue profile can be calculated. The profile of the patient is fed into the computer by way of a video system and correlated to the ceph. Using the simulated operation the computer calculates a new video image of the patient which presents the expected postoperative appearance. In studies of patients treated between 1987-91, 76 out of 121 patients were able to be evaluated. The deviation in profile change varied between .0 and 1.6mm. A side effect of the practical applications was an increase in patient compliance.

  12. Interactive virtual simulation using a 3D computer graphics model for microvascular decompression surgery.

    Science.gov (United States)

    Oishi, Makoto; Fukuda, Masafumi; Hiraishi, Tetsuya; Yajima, Naoki; Sato, Yosuke; Fujii, Yukihiko

    2012-09-01

    The purpose of this paper is to report on the authors' advanced presurgical interactive virtual simulation technique using a 3D computer graphics model for microvascular decompression (MVD) surgery. The authors performed interactive virtual simulation prior to surgery in 26 patients with trigeminal neuralgia or hemifacial spasm. The 3D computer graphics models for interactive virtual simulation were composed of the brainstem, cerebellum, cranial nerves, vessels, and skull individually created by the image analysis, including segmentation, surface rendering, and data fusion for data collected by 3-T MRI and 64-row multidetector CT systems. Interactive virtual simulation was performed by employing novel computer-aided design software with manipulation of a haptic device to imitate the surgical procedures of bone drilling and retraction of the cerebellum. The findings were compared with intraoperative findings. In all patients, interactive virtual simulation provided detailed and realistic surgical perspectives, of sufficient quality, representing the lateral suboccipital route. The causes of trigeminal neuralgia or hemifacial spasm determined by observing 3D computer graphics models were concordant with those identified intraoperatively in 25 (96%) of 26 patients, which was a significantly higher rate than the 73% concordance rate (concordance in 19 of 26 patients) obtained by review of 2D images only (p computer graphics model provided a realistic environment for performing virtual simulations prior to MVD surgery and enabled us to ascertain complex microsurgical anatomy.

  13. Middle Ear Infections and Ear Tube Surgery (For Parents)

    Science.gov (United States)

    ... them because of environmental and lifestyle factors (like attendance at a group childcare, secondhand tobacco smoke exposure, ... View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  14. 'Outrunning' the running ear

    African Journals Online (AJOL)

    Chantel

    In even the most experienced hands, an adequate physical examination of the ears can be difficult to perform because of common problems such as cerumen blockage of the auditory canal, an unco- operative toddler or an exasperated parent. The most common cause for a running ear in a child is acute purulent otitis.

  15. "Swimmer's Ear" (Otitis Externa) Prevention

    Science.gov (United States)

    ... infections, swimmer’s ear, and healthy swimming. "Swimmer's Ear" (Otitis Externa) What are the symptoms of swimmer's ear? ... Healthy page. Reference CDC. Estimated burden of acute otitis externa —United States, 2003–2007 . MMWR Morb Mortal ...

  16. Clinical application of 3D computer simulation for upper limb surgery

    International Nuclear Information System (INIS)

    Murase, Tsuyoshi; Moritomo, Hisao; Oka, Kunihiro; Arimitsu, Sayuri; Shimada, Kozo

    2008-01-01

    To perform precise orthopaedic surgery, we have been developing a surgical method using a custom-made surgical device designed based on preoperative three-dimensional computer simulation. The purpose of this study was to investigate the preliminary results of its clinical application for corrective osteotomy of the upper extremity. Twenty patients with long bone deformities of the upper extremities (four cubitus varus deformities, nine malunited forearm fractures, six malunited distal radial fractures and one congenital deformity of the forearm) participated in this study. Three-dimensional computer models of the affected bone and the contralateral normal bone were constructed from computed tomography data. By comparing these models, the three-dimensional deformity axis and the accurate amount of deformity around it were quantified. Three-dimensional deformity correction was then simulated. A custom-made osteotomy template was designed and manufactured as a real plastic model aiming to reproduce the preoperative simulation in the actual operation. In the operation, we put the template on the bone surface, cut the bone through a slit on the template, and corrected the deformity as preoperatively simulated, followed by internal fixation. Radiographic and clinical evaluations were made in all cases before surgery and at the most recent follow-up. Corrective osteotomy was achieved as simulated in all cases. All patients had bone fusion within six months. Regarding the cubitus varus deformity, the average carrying angle and tilting angle were 5deg and 28deg after surgery. For malunited forearm fractures, angular deformities on radiographs were nearly nonexistent after surgery. All radiographic parameters in malunited distal radius fractures were normalized. The range of forearm rotation in cases of forearm malunion and that of wrist flexion-extension in cases of malunited distal radius improved after surgery. (author)

  17. Face, content and construct validity of a virtual reality simulator for robotic surgery (SEP Robot).

    Science.gov (United States)

    Gavazzi, Andrea; Bahsoun, Ali N; Van Haute, Wim; Ahmed, Kamran; Elhage, Oussama; Jaye, Peter; Khan, M Shamim; Dasgupta, Prokar

    2011-03-01

    This study aims to establish face, content and construct validation of the SEP Robot (SimSurgery, Oslo, Norway) in order to determine its value as a training tool. The tasks used in the validation of this simulator were arrow manipulation and performing a surgeon's knot. Thirty participants (18 novices, 12 experts) completed the procedures. The simulator was able to differentiate between experts and novices in several respects. The novice group required more time to complete the tasks than the expert group, especially suturing. During the surgeon's knot exercise, experts significantly outperformed novices in maximum tightening stretch, instruments dropped, maximum winding stretch and tool collisions in addition to total task time. A trend was found towards the use of less force by the more experienced participants. The SEP robotic simulator has demonstrated face, content and construct validity as a virtual reality simulator for robotic surgery. With steady increase in adoption of robotic surgery world-wide, this simulator may prove to be a valuable adjunct to clinical mentorship.

  18. High correlation between performance on a virtual-reality simulator and real-life cataract surgery

    DEFF Research Database (Denmark)

    Thomsen, Ann Sofia Skou; Smith, Phillip; Subhi, Yousif

    2017-01-01

    -tracking software of cataract surgical videos with a Pearson correlation coefficient of -0.70 (p = 0.017). CONCLUSION: Performance on the EyeSi simulator is significantly and highly correlated to real-life surgical performance. However, it is recommended that performance assessments are made using multiple data......PURPOSE: To investigate the correlation in performance of cataract surgery between a virtual-reality simulator and real-life surgery using two objective assessment tools with evidence of validity. METHODS: Cataract surgeons with varying levels of experience were included in the study. All...... antitremor training, forceps training, bimanual training, capsulorhexis and phaco divide and conquer. RESULTS: Eleven surgeons were enrolled. After a designated warm-up period, the proficiency-based test on the EyeSi simulator was strongly correlated to real-life performance measured by motion...

  19. Educational program in crisis management for cardiac surgery teams including high realism simulation.

    Science.gov (United States)

    Stevens, Louis-Mathieu; Cooper, Jeffrey B; Raemer, Daniel B; Schneider, Robert C; Frankel, Allan S; Berry, William R; Agnihotri, Arvind K

    2012-07-01

    Cardiac surgery demands effective teamwork for safe, high-quality care. The objective of this pilot study was to develop a comprehensive program to sharpen performance of experienced cardiac surgical teams in acute crisis management. We developed and implemented an educational program for cardiac surgery based on high realism acute crisis simulation scenarios and interactive whole-unit workshop. The impact of these interventions was assessed with postintervention questionnaires, preintervention and 6-month postintervention surveys, and structured interviews. The realism of the acute crisis simulation scenarios gradually improved; most participants rated both the simulation and whole-unit workshop as very good or excellent. Repeat simulation training was recommended every 6 to 12 months by 82% of the participants. Participants of the interactive workshop identified 2 areas of highest priority: encouraging speaking up about critical information and interprofessional information sharing. They also stressed the importance of briefings, early communication of surgical plan, knowing members of the team, and continued simulation for practice. The pre/post survey response rates were 70% (55/79) and 66% (52/79), respectively. The concept of working as a team improved between surveys (P = .028), with a trend for improvement in gaining common understanding of the plan before a procedure (P = .075) and appropriate resolution of disagreements (P = .092). Interviewees reported that the training had a positive effect on their personal behaviors and patient care, including speaking up more readily and communicating more clearly. Comprehensive team training using simulation and a whole-unit interactive workshop can be successfully deployed for experienced cardiac surgery teams with demonstrable benefits in participant's perception of team performance. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  20. A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery.

    Science.gov (United States)

    Moglia, Andrea; Ferrari, Vincenzo; Morelli, Luca; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred

    2016-06-01

    No single large published randomized controlled trial (RCT) has confirmed the efficacy of virtual simulators in the acquisition of skills to the standard required for safe clinical robotic surgery. This remains the main obstacle for the adoption of these virtual simulators in surgical residency curricula. To evaluate the level of evidence in published studies on the efficacy of training on virtual simulators for robotic surgery. In April 2015 a literature search was conducted on PubMed, Web of Science, Scopus, Cochrane Library, the Clinical Trials Database (US) and the Meta Register of Controlled Trials. All publications were scrutinized for relevance to the review and for assessment of the levels of evidence provided using the classification developed by the Oxford Centre for Evidence-Based Medicine. The publications included in the review consisted of one RCT and 28 cohort studies on validity, and seven RCTs and two cohort studies on skills transfer from virtual simulators to robot-assisted surgery. Simulators were rated good for realism (face validity) and for usefulness as a training tool (content validity). However, the studies included used various simulation training methodologies, limiting the assessment of construct validity. The review confirms the absence of any consensus on which tasks and metrics are the most effective for the da Vinci Skills Simulator and dV-Trainer, the most widely investigated systems. Although there is consensus for the RoSS simulator, this is based on only two studies on construct validity involving four exercises. One study on initial evaluation of an augmented reality module for partial nephrectomy using the dV-Trainer reported high correlation (r=0.8) between in vivo porcine nephrectomy and a virtual renorrhaphy task according to the overall Global Evaluation Assessment of Robotic Surgery (GEARS) score. In one RCT on skills transfer, the experimental group outperformed the control group, with a significant difference in overall

  1. Using virtual reality simulation to assess competence in video-assisted thoracoscopic surgery (VATS) lobectomy.

    Science.gov (United States)

    Jensen, Katrine; Bjerrum, Flemming; Hansen, Henrik Jessen; Petersen, René Horsleben; Pedersen, Jesper Holst; Konge, Lars

    2017-06-01

    The societies of thoracic surgery are working to incorporate simulation and competency-based assessment into specialty training. One challenge is the development of a simulation-based test, which can be used as an assessment tool. The study objective was to establish validity evidence for a virtual reality simulator test of a video-assisted thoracoscopic surgery (VATS) lobectomy of a right upper lobe. Participants with varying experience in VATS lobectomy were included. They were familiarized with a virtual reality simulator (LapSim ® ) and introduced to the steps of the procedure for a VATS right upper lobe lobectomy. The participants performed two VATS lobectomies on the simulator with a 5-min break between attempts. Nineteen pre-defined simulator metrics were recorded. Fifty-three participants from nine different countries were included. High internal consistency was found for the metrics with Cronbach's alpha coefficient for standardized items of 0.91. Significant test-retest reliability was found for 15 of the metrics (p-values 50 VATS lobectomies performed). A pass/fail level defined as approximately one standard deviation from the mean metric scores for experienced surgeons passed none of the novices (0 % false positives) and failed four of the experienced surgeons (29 % false negatives). This study is the first to establish validity evidence for a VATS right upper lobe lobectomy virtual reality simulator test. Several simulator metrics demonstrated significant differences between novices and experienced surgeons and pass/fail criteria for the test were set with acceptable consequences. This test can be used as a first step in assessing thoracic surgery trainees' VATS lobectomy competency.

  2. The rationale for combining an online audiovisual curriculum with simulation to better educate general surgery trainees.

    Science.gov (United States)

    AlJamal, Yazan N; Ali, Shahzad M; Ruparel, Raaj K; Brahmbhatt, Rushin D; Yadav, Siddhant; Farley, David R

    2014-09-01

    Surgery interns' training has historically been weighted toward patient care, operative observation, and sleeping when possible. With more protected free time and less clinical time, real educational hours for trainees in 2013 are precious. We created a 20-session (3 hours each) simulation curriculum (with pre- and post-tests) and a 24/7 online audiovisual (AV) curriculum for surgery interns. Friday morning simulation sessions emphasize operative skills and judgment. AV clips (using operating room, whiteboard, and simulation center videos) take learners through 20 different general surgery operations with follow-up quizzes. We report our early experience with this novel setup. Thirty-two surgical interns (2012-2013) attended simulation sessions on 20 separate subjects (hernia, breast, hepatobiliary, endocrine, etc). Post-test scores improved (P 4.5; Likert scale, 1-5). The AV curriculum feedback is similar (mean, >4.3) and usage is available 24/7 preparing learners for both operating room and simulation sessions. Most simulation sessions utilize low-fidelity models to keep costs <$50 per session. Scores on our semiannual Surgical Olympics (mean score of 49.6 in July vs 82.9 in January; P < .05) improved significantly, suggesting that interns are improving their surgical skills and knowledge. Residents enjoy and learn from the step-by-step, in-house, AV curriculum and both appreciate and thrive on the 'hands-on' simulation sessions mimicking operations they see in real operating rooms. The cost of these programs is not prohibitive and the programs offer simulated repetitions for duty-hour-regulated trainees. Copyright © 2014 Mosby, Inc. All rights reserved.

  3. What is going on in augmented reality simulation in laparoscopic surgery?

    Science.gov (United States)

    Botden, Sanne M B I; Jakimowicz, Jack J

    2009-08-01

    To prevent unnecessary errors and adverse results of laparoscopic surgery, proper training is of paramount importance. A safe way to train surgeons for laparoscopic skills is simulation. For this purpose traditional box trainers are often used, however they lack objective assessment of performance. Virtual reality laparoscopic simulators assess performance, but lack realistic haptic feedback. Augmented reality (AR) combines a virtual reality (VR) setting with real physical materials, instruments, and feedback. This article presents the current developments in augmented reality laparoscopic simulation. Pubmed searches were performed to identify articles regarding surgical simulation and augmented reality. Identified companies manufacturing an AR laparoscopic simulator received the same questionnaire referring to the features of the simulator. Seven simulators that fitted the definition of augmented reality were identified during the literature search. Five of the approached manufacturers returned a completed questionnaire, of which one simulator appeared to be VR and was therefore not applicable for this review. Several augmented reality simulators have been developed over the past few years and they are improving rapidly. We recommend the development of AR laparoscopic simulators for component tasks of procedural training. AR simulators should be implemented in current laparoscopic training curricula, in particular for laparoscopic suturing training.

  4. Ear Problems in Swimmers

    Directory of Open Access Journals (Sweden)

    Mao-Che Wang

    2005-08-01

    Full Text Available Acute diffuse otitis externa (swimmer's ear, otomycosis, exostoses, traumatic eardrum perforation, middle ear infection, and barotraumas of the inner ear are common problems in swimmers and people engaged in aqua activities. The most common ear problem in swimmers is acute diffuse otitis externa, with Pseudomonas aeruginosa being the most common pathogen. The symptoms are itching, otalgia, otorrhea, and conductive hearing loss. The treatment includes frequent cleansing of the ear canal, pain control, oral or topical medications, acidification of the ear canal, and control of predisposing factors. Swimming in polluted waters and ear-canal cleaning with cotton-tip applicators should be avoided. Exostoses are usually seen in people who swim in cold water and present with symptoms of accumulated debris, otorrhea and conductive hearing loss. The treatment for exostoses is transmeatal surgical removal of the tumors. Traumatic eardrum perforations may occur during water skiing or scuba diving and present with symptoms of hearing loss, otalgia, otorrhea, tinnitus and vertigo. Tympanoplasty might be needed if the perforations do not heal spontaneously. Patients with chronic otitis media with active drainage should avoid swimming, while patients who have undergone mastoidectomy and who have no cavity problems may swim. For children with ventilation tubes, surface swimming is safe in a clean, chlorinated swimming pool. Sudden sensorineural hearing loss and some degree of vertigo may occur after diving because of rupture of the round or oval window membrane.

  5. Fluid structure interaction simulations of the upper airway in obstructive sleep apnea patients before and after maxillomandibular advancement surgery.

    Science.gov (United States)

    Chang, Kwang K; Kim, Ki Beom; McQuilling, Mark W; Movahed, Reza

    2018-06-01

    The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  6. A 3D virtual reality simulator for training of minimally invasive surgery.

    Science.gov (United States)

    Mi, Shao-Hua; Hou, Zeng-Gunag; Yang, Fan; Xie, Xiao-Liang; Bian, Gui-Bin

    2014-01-01

    For the last decade, remarkable progress has been made in the field of cardiovascular disease treatment. However, these complex medical procedures require a combination of rich experience and technical skills. In this paper, a 3D virtual reality simulator for core skills training in minimally invasive surgery is presented. The system can generate realistic 3D vascular models segmented from patient datasets, including a beating heart, and provide a real-time computation of force and force feedback module for surgical simulation. Instruments, such as a catheter or guide wire, are represented by a multi-body mass-spring model. In addition, a realistic user interface with multiple windows and real-time 3D views are developed. Moreover, the simulator is also provided with a human-machine interaction module that gives doctors the sense of touch during the surgery training, enables them to control the motion of a virtual catheter/guide wire inside a complex vascular model. Experimental results show that the simulator is suitable for minimally invasive surgery training.

  7. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus

    2016-11-01

    Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.

  8. A virtual reality endoscopic simulator augments general surgery resident cancer education as measured by performance improvement.

    Science.gov (United States)

    White, Ian; Buchberg, Brian; Tsikitis, V Liana; Herzig, Daniel O; Vetto, John T; Lu, Kim C

    2014-06-01

    Colorectal cancer is the second most common cause of death in the USA. The need for screening colonoscopies, and thus adequately trained endoscopists, particularly in rural areas, is on the rise. Recent increases in required endoscopic cases for surgical resident graduation by the Surgery Residency Review Committee (RRC) further emphasize the need for more effective endoscopic training during residency to determine if a virtual reality colonoscopy simulator enhances surgical resident endoscopic education by detecting improvement in colonoscopy skills before and after 6 weeks of formal clinical endoscopic training. We conducted a retrospective review of prospectively collected surgery resident data on an endoscopy simulator. Residents performed four different clinical scenarios on the endoscopic simulator before and after a 6-week endoscopic training course. Data were collected over a 5-year period from 94 different residents performing a total of 795 colonoscopic simulation scenarios. Main outcome measures included time to cecal intubation, "red out" time, and severity of simulated patient discomfort (mild, moderate, severe, extreme) during colonoscopy scenarios. Average time to intubation of the cecum was 6.8 min for those residents who had not undergone endoscopic training versus 4.4 min for those who had undergone endoscopic training (p Virtual reality endoscopic simulation is an effective tool for both augmenting surgical resident endoscopy cancer education and measuring improvement in resident performance after formal clinical endoscopic training.

  9. External Otitis (Swimmer's Ear)

    Science.gov (United States)

    ... otitis. Fungal external otitis (otomycosis), typically caused by Aspergillus niger or Candida albicans, is less common. Boils are ... in the ear. Fungal external otitis caused by Aspergillus niger usually causes grayish black or yellow dots (called ...

  10. Ear Infections in Children

    Science.gov (United States)

    ... ear infections may get better without antibiotics. Using antibiotics cautiously and with good reason helps prevent the development of bacteria that become resistant to antibiotics. If your doctor prescribes an antibiotic, it’s important ...

  11. Simulation in paediatric urology and surgery, part 2: An overview of simulation modalities and their applications.

    Science.gov (United States)

    Nataraja, R M; Webb, N; Lopez, P J

    2018-02-02

    Surgical training has changed radically in the last few decades. The traditional Halstedian model of time-bound apprenticeship has been replaced with competency-based training. In our previous article, we presented an overview of learning theory relevant to clinical teaching; a summary for the busy paediatric surgeon and urologist. We introduced the concepts underpinning current changes in surgical education and training. In this next article, we give an overview of the various modalities of surgical simulation, the educational principles that underlie them, and potential applications in clinical practice. These modalities include; open surgical models and trainers, laparoscopic bench trainers, virtual reality trainers, simulated patients and role-play, hybrid simulation, scenario-based simulation, distributed simulation, virtual reality, and online simulation. Specific examples of technology that may be used for these modalities are included but this is not a comprehensive review of all available products. Copyright © 2018 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  12. Towards open-source, low-cost haptics for surgery simulation.

    Science.gov (United States)

    Suwelack, Stefan; Sander, Christian; Schill, Julian; Serf, Manuel; Danz, Marcel; Asfour, Tamim; Burger, Wolfgang; Dillmann, Rüdiger; Speidel, Stefanie

    2014-01-01

    In minimally invasive surgery (MIS), virtual reality (VR) training systems have become a promising education tool. However, the adoption of these systems in research and clinical settings is still limited by the high costs of dedicated haptics hardware for MIS. In this paper, we present ongoing research towards an open-source, low-cost haptic interface for MIS simulation. We demonstrate the basic mechanical design of the device, the sensor setup as well as its software integration.

  13. "Just-In-Time" Simulation Training Using 3-D Printed Cardiac Models After Congenital Cardiac Surgery.

    Science.gov (United States)

    Olivieri, Laura J; Su, Lillian; Hynes, Conor F; Krieger, Axel; Alfares, Fahad A; Ramakrishnan, Karthik; Zurakowski, David; Marshall, M Blair; Kim, Peter C W; Jonas, Richard A; Nath, Dilip S

    2016-03-01

    High-fidelity simulation using patient-specific three-dimensional (3D) models may be effective in facilitating pediatric cardiac intensive care unit (PCICU) provider training for clinical management of congenital cardiac surgery patients. The 3D-printed heart models were rendered from preoperative cross-sectional cardiac imaging for 10 patients undergoing congenital cardiac surgery. Immediately following surgical repair, a congenital cardiac surgeon and an intensive care physician conducted a simulation training session regarding postoperative care utilizing the patient-specific 3D model for the PCICU team. After the simulation, Likert-type 0 to 10 scale questionnaire assessed participant perception of impact of the training session. Seventy clinicians participated in training sessions, including 22 physicians, 38 nurses, and 10 ancillary care providers. Average response to whether 3D models were more helpful than standard hand off was 8.4 of 10. Questions regarding enhancement of understanding and clinical ability received average responses of 9.0 or greater, and 90% of participants scored 8 of 10 or higher. Nurses scored significantly higher than other clinicians on self-reported familiarity with the surgery (7.1 vs. 5.8; P = .04), clinical management ability (8.6 vs. 7.7; P = .02), and ability enhancement (9.5 vs. 8.7; P = .02). Compared to physicians, nurses and ancillary providers were more likely to consider 3D models more helpful than standard hand off (8.7 vs. 7.7; P = .05). Higher case complexity predicted greater enhancement of understanding of surgery (P = .04). The 3D heart models can be used to enhance congenital cardiac critical care via simulation training of multidisciplinary intensive care teams. Benefit may be dependent on provider type and case complexity. © The Author(s) 2016.

  14. A National Needs Assessment to Identify Technical Procedures in Vascular Surgery for Simulation Based Training.

    Science.gov (United States)

    Nayahangan, L J; Konge, L; Schroeder, T V; Paltved, C; Lindorff-Larsen, K G; Nielsen, B U; Eiberg, J P

    2017-04-01

    Practical skills training in vascular surgery is facing challenges because of an increased number of endovascular procedures and fewer open procedures, as well as a move away from the traditional principle of "learning by doing." This change has established simulation as a cornerstone in providing trainees with the necessary skills and competences. However, the development of simulation based programs often evolves based on available resources and equipment, reflecting convenience rather than a systematic educational plan. The objective of the present study was to perform a national needs assessment to identify the technical procedures that should be integrated in a simulation based curriculum. A national needs assessment using a Delphi process was initiated by engaging 33 predefined key persons in vascular surgery. Round 1 was a brainstorming phase to identify technical procedures that vascular surgeons should learn. Round 2 was a survey that used a needs assessment formula to explore the frequency of procedures, the number of surgeons performing each procedure, risk and/or discomfort, and feasibility for simulation based training. Round 3 involved elimination and ranking of procedures. The response rate for round 1 was 70%, with 36 procedures identified. Round 2 had a 76% response rate and resulted in a preliminary prioritised list after exploring the need for simulation based training. Round 3 had an 85% response rate; 17 procedures were eliminated, resulting in a final prioritised list of 19 technical procedures. A national needs assessment using a standardised Delphi method identified a list of procedures that are highly suitable and may provide the basis for future simulation based training programs for vascular surgeons in training. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Innovations in surgery simulation: a review of past, current and future techniques.

    Science.gov (United States)

    Badash, Ido; Burtt, Karen; Solorzano, Carlos A; Carey, Joseph N

    2016-12-01

    As a result of recent work-hours limitations and concerns for patient safety, innovations in extraclinical surgical simulation have become a desired part of residency education. Current simulation models, including cadaveric, animal, bench-top, virtual reality (VR) and robotic simulators are increasingly used in surgical training programs. Advances in telesurgery, three-dimensional (3D) printing, and the incorporation of patient-specific anatomy are paving the way for simulators to become integral components of medical training in the future. Evidence from the literature highlights the benefits of including simulations in surgical training; skills acquired through simulations translate into improvements in operating room performance. Moreover, simulations are rapidly incorporating new medical technologies and offer increasingly high-fidelity recreations of procedures. As a result, both novice and expert surgeons are able to benefit from their use. As dedicated, structured curricula are developed that incorporate simulations into daily resident training, simulated surgeries will strengthen the surgeon's skill set, decrease hospital costs, and improve patient outcomes.

  16. Resident simulation training in endoscopic endonasal surgery utilizing haptic feedback technology.

    Science.gov (United States)

    Thawani, Jayesh P; Ramayya, Ashwin G; Abdullah, Kalil G; Hudgins, Eric; Vaughan, Kerry; Piazza, Matthew; Madsen, Peter J; Buch, Vivek; Sean Grady, M

    2016-12-01

    Simulated practice may improve resident performance in endoscopic endonasal surgery. Using the NeuroTouch haptic simulation platform, we evaluated resident performance and assessed the effect of simulation training on performance in the operating room. First- (N=3) and second- (N=3) year residents were assessed using six measures of proficiency. Using a visual analog scale, the senior author scored subjects. After the first session, subjects with lower scores were provided with simulation training. A second simulation served as a task-learning control. Residents were evaluated in the operating room over six months by the senior author-who was blinded to the trained/untrained identities-using the same parameters. A nonparametric bootstrap testing method was used for the analysis (Matlab v. 2014a). Simulation training was associated with an increase in performance scores in the operating room averaged over all measures (p=0.0045). This is the first study to evaluate the training utility of an endoscopic endonasal surgical task using a virtual reality haptic simulator. The data suggest that haptic simulation training in endoscopic neurosurgery may contribute to improvements in operative performance. Limitations include a small number of subjects and adjudication bias-although the trained/untrained identity of subjects was blinded. Further study using the proposed methods may better describe the relationship between simulated training and operative performance in endoscopic Neurosurgery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. [Research progress on real-time deformable models of soft tissues for surgery simulation].

    Science.gov (United States)

    Xu, Shaoping; Liu, Xiaoping; Zhang, Hua; Luo, Jie

    2010-04-01

    Biological tissues generally exhibit nonlinearity, anisotropy, quasi-incompressibility and viscoelasticity about material properties. Simulating the behaviour of elastic objects in real time is one of the current objectives of virtual surgery simulation which is still a challenge for researchers to accurately depict the behaviour of human tissues. In this paper, we present a classification of the different deformable models that have been developed. We present the advantages and disadvantages of each one. Finally, we make a comparison of deformable models and perform an evaluation of the state of the art and the future of deformable models.

  18. Computer Simulation Surgery for Mandibular Reconstruction Using a Fibular Osteotomy Guide

    Directory of Open Access Journals (Sweden)

    Woo Shik Jeong

    2014-09-01

    Full Text Available In the present study, a fibular osteotomy guide based on a computer simulation was applied to a patient who had undergone mandibular segmental ostectomy due to oncological complications. This patient was a 68-year-old woman who presented to our department with a biopsy-proven squamous cell carcinoma on her left gingival area. This lesion had destroyed the cortical bony structure, and the patient showed attenuation of her soft tissue along the inferior alveolar nerve, indicating perineural spread of the tumor. Prior to surgery, a three-dimensional computed tomography scan of the facial and fibular bones was performed. We then created a virtual computer simulation of the mandibular segmental defect through which we segmented the fibular to reconstruct the proper angulation in the original mandible. Approximately 2-cm segments were created on the basis of this simulation and applied to the virtually simulated mandibular segmental defect. Thus, we obtained a virtual model of the ideal mandibular reconstruction for this patient with a fibular free flap. We could then use this computer simulation for the subsequent surgery and minimize the bony gaps between the multiple fibular bony segments.

  19. Aberrant internal carotid artery in the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Keun Tak; Kang, Hyun Koo [Dept. of Radiology, Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2014-10-15

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  20. Aberrant internal carotid artery in the middle ear

    International Nuclear Information System (INIS)

    Roh, Keun Tak; Kang, Hyun Koo

    2014-01-01

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  1. The McGill simulator for endoscopic sinus surgery (MSESS): a validation study.

    Science.gov (United States)

    Varshney, Rickul; Frenkiel, Saul; Nguyen, Lily H P; Young, Meredith; Del Maestro, Rolando; Zeitouni, Anthony; Saad, Elias; Funnell, W Robert J; Tewfik, Marc A

    2014-10-24

    Endoscopic sinus surgery (ESS) is a technically challenging procedure, associated with a significant risk of complications. Virtual reality simulation has demonstrated benefit in many disciplines as an important educational tool for surgical training. Within the field of rhinology, there is a lack of ESS simulators with appropriate validity evidence supporting their integration into residency education. The objectives of this study are to evaluate the acceptability, perceived realism and benefit of the McGill Simulator for Endoscopic Sinus Surgery (MSESS) among medical students, otolaryngology residents and faculty, and to present evidence supporting its ability to differentiate users based on their level of training through the performance metrics. 10 medical students, 10 junior residents, 10 senior residents and 3 expert sinus surgeons performed anterior ethmoidectomies, posterior ethmoidectomies and wide sphenoidotomies on the MSESS. Performance metrics related to quality (e.g. percentage of tissue removed), efficiency (e.g. time, path length, bimanual dexterity, etc.) and safety (e.g. contact with no-go zones, maximum applied force, etc.) were calculated. All users completed a post-simulation questionnaire related to realism, usefulness and perceived benefits of training on the MSESS. The MSESS was found to be realistic and useful for training surgical skills with scores of 7.97 ± 0.29 and 8.57 ± 0.69, respectively on a 10-point rating scale. Most students and residents (29/30) believed that it should be incorporated into their curriculum. There were significant differences between novice surgeons (10 medical students and 10 junior residents) and senior surgeons (10 senior residents and 3 sinus surgeons) in performance metrics related to quality (p education. This simulator may be a potential resource to help fill the void in endoscopic sinus surgery training.

  2. Cardiovascular Surgery Residency Program: Training Coronary Anastomosis Using the Arroyo Simulator and UNIFESP Models.

    Science.gov (United States)

    Maluf, Miguel Angel; Gomes, Walter José; Bras, Ademir Massarico; Araújo, Thiago Cavalcante Vila Nova de; Mota, André Lupp; Cardoso, Caio Cesar; Coutinho, Rafael Viana dos S

    2015-01-01

    Engage the UNIFESP Cardiovascular Surgery residents in coronary anastomosis, assess their skills and certify results, using the Arroyo Anastomosis Simulator and UNIFESP surgical models. First to 6th year residents attended a weekly program of technical training in coronary anastomosis, using 4 simulation models: 1. Arroyo simulator; 2. Dummy with a plastic heart; 3. Dummy with a bovine heart; and 4. Dummy with a beating pig heart. The assessment test was comprised of 10 items, using a scale from 1 to 5 points in each of them, creating a global score of 50 points maximum. The technical performance of the candidate showed improvement in all items, especially manual skill and technical progress, critical sense of the work performed, confidence in the procedure and reduction of the time needed to perform the anastomosis after 12 weeks practice. In response to the multiplicity of factors that currently influence the cardiovascular surgeon training, there have been combined efforts to reform the practices of surgical medical training. 1 - The four models of simulators offer a considerable contribution to the field of cardiovascular surgery, improving the skill and dexterity of the surgeon in training. 2 - Residents have shown interest in training and cooperate in the development of innovative procedures for surgical medical training in the art.

  3. Mixed reality simulation of rasping procedure in artificial cervical disc replacement (ACDR) surgery.

    Science.gov (United States)

    Halic, Tansel; Kockara, Sinan; Bayrak, Coskun; Rowe, Richard

    2010-10-07

    Until quite recently spinal disorder problems in the U.S. have been operated by fusing cervical vertebrae instead of replacement of the cervical disc with an artificial disc. Cervical disc replacement is a recently approved procedure in the U.S. It is one of the most challenging surgical procedures in the medical field due to the deficiencies in available diagnostic tools and insufficient number of surgical practices For physicians and surgical instrument developers, it is critical to understand how to successfully deploy the new artificial disc replacement systems. Without proper understanding and practice of the deployment procedure, it is possible to injure the vertebral body. Mixed reality (MR) and virtual reality (VR) surgical simulators are becoming an indispensable part of physicians' training, since they offer a risk free training environment. In this study, MR simulation framework and intricacies involved in the development of a MR simulator for the rasping procedure in artificial cervical disc replacement (ACDR) surgery are investigated. The major components that make up the MR surgical simulator with motion tracking system are addressed. A mixed reality surgical simulator that targets rasping procedure in the artificial cervical disc replacement surgery with a VICON motion tracking system was developed. There were several challenges in the development of MR surgical simulator. First, the assembly of different hardware components for surgical simulation development that involves knowledge and application of interdisciplinary fields such as signal processing, computer vision and graphics, along with the design and placements of sensors etc . Second challenge was the creation of a physically correct model of the rasping procedure in order to attain critical forces. This challenge was handled with finite element modeling. The third challenge was minimization of error in mapping movements of an actor in real model to a virtual model in a process called

  4. Validation of ergonomic instructions in robot-assisted surgery simulator training.

    Science.gov (United States)

    Van't Hullenaar, C D P; Mertens, A C; Ruurda, J P; Broeders, I A M J

    2018-05-01

    Training in robot-assisted surgery focusses mainly on technical skills and instrument use. Training in optimal ergonomics during robotic surgery is often lacking, while improved ergonomics can be one of the key advantages of robot-assisted surgery. Therefore, the aim of this study was to assess whether a brief explanation on ergonomics of the console can improve body posture and performance. A comparative study was performed with 26 surgical interns and residents using the da Vinci skills simulator (Intuitive Surgical, Sunnyvale, CA). The intervention group received a compact instruction on ergonomic settings and coaching on clutch usage, while the control group received standard instructions for usage of the system. Participants performed two sets of five exercises. Analysis was performed on ergonomic score (RULA) and performance scores provided by the simulator. Mental and physical load scores (NASA-TLX and LED score) were also registered. The intervention group performed better in the clutch-oriented exercises, displaying less unnecessary movement and smaller deviation from the neutral position of the hands. The intervention group also scored significantly better on the RULA ergonomic score in both the exercises. No differences in overall performance scores and subjective scores were detected. The benefits of a brief instruction on ergonomics for novices are clear in this study. A single session of coaching and instruction leads to better ergonomic scores. The control group showed often inadequate ergonomic scores. No significant differences were found regarding physical discomfort, mental task load and overall performance scores.

  5. Current Status of Simulation-based Training Tools in Orthopedic Surgery: A Systematic Review.

    Science.gov (United States)

    Morgan, Michael; Aydin, Abdullatif; Salih, Alan; Robati, Shibby; Ahmed, Kamran

    To conduct a systematic review of orthopedic training and assessment simulators with reference to their level of evidence (LoE) and level of recommendation. Medline and EMBASE library databases were searched for English language articles published between 1980 and 2016, describing orthopedic simulators or validation studies of these models. All studies were assessed for LoE, and each model was subsequently awarded a level of recommendation using a modified Oxford Centre for Evidence-Based Medicine classification, adapted for education. A total of 76 articles describing orthopedic simulators met the inclusion criteria, 47 of which described at least 1 validation study. The most commonly identified models (n = 34) and validation studies (n = 26) were for knee arthroscopy. Construct validation was the most frequent validation study attempted by authors. In all, 62% (47 of 76) of the simulator studies described arthroscopy simulators, which also contained validation studies with the highest LoE. Orthopedic simulators are increasingly being subjected to validation studies, although the LoE of such studies generally remain low. There remains a lack of focus on nontechnical skills and on cost analyses of orthopedic simulators. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  6. Artificial muscles for a novel simulator in minimally invasive spine surgery.

    Science.gov (United States)

    Hollensteiner, Marianne; Fuerst, David; Schrempf, Andreas

    2014-01-01

    Vertebroplasty and kyphoplasty are commonly used minimally invasive methods to treat vertebral compression fractures. Novice surgeons gather surgical skills in different ways, mainly by "learning by doing" or training on models, specimens or simulators. Currently, a new training modality, an augmented reality simulator for minimally invasive spine surgeries, is going to be developed. An important step in investigating this simulator is the accurate establishment of artificial tissues. Especially vertebrae and muscles, reproducing a comparable haptical feedback during tool insertion, are necessary. Two artificial tissues were developed to imitate natural muscle tissue. The axial insertion force was used as validation parameter. It appropriates the mechanical properties of artificial and natural muscles. Validation was performed on insertion measurement data from fifteen artificial muscle tissues compared to human muscles measurement data. Based on the resulting forces during needle insertion into human muscles, a suitable material composition for manufacturing artificial muscles was found.

  7. A National Needs Assessment to Identify Technical Procedures in Vascular Surgery for Simulation Based Training

    DEFF Research Database (Denmark)

    Nayahangan, L J; Konge, L; Schroeder, T V

    2017-01-01

    to identify technical procedures that vascular surgeons should learn. Round 2 was a survey that used a needs assessment formula to explore the frequency of procedures, the number of surgeons performing each procedure, risk and/or discomfort, and feasibility for simulation based training. Round 3 involved...... eliminated, resulting in a final prioritised list of 19 technical procedures. Conclusion A national needs assessment using a standardised Delphi method identified a list of procedures that are highly suitable and may provide the basis for future simulation based training programs for vascular surgeons......Objectives and background Practical skills training in vascular surgery is facing challenges because of an increased number of endovascular procedures and fewer open procedures, as well as a move away from the traditional principle of “learning by doing.” This change has established simulation...

  8. Pre-operative simulation of pediatric mastoid surgery with 3D-printed temporal bone models.

    Science.gov (United States)

    Rose, Austin S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Rawal, Rounak B; Iseli, Claire E

    2015-05-01

    As the process of additive manufacturing, or three-dimensional (3D) printing, has become more practical and affordable, a number of applications for the technology in the field of pediatric otolaryngology have been considered. One area of promise is temporal bone surgical simulation. Having previously developed a model for temporal bone surgical training using 3D printing, we sought to produce a patient-specific model for pre-operative simulation in pediatric otologic surgery. Our hypothesis was that the creation and pre-operative dissection of such a model was possible, and would demonstrate potential benefits in cases of abnormal temporal bone anatomy. In the case presented, an 11-year-old boy underwent a planned canal-wall-down (CWD) tympano-mastoidectomy for recurrent cholesteatoma preceded by a pre-operative surgical simulation using 3D-printed models of the temporal bone. The models were based on the child's pre-operative clinical CT scan and printed using multiple materials to simulate both bone and soft tissue structures. To help confirm the models as accurate representations of the child's anatomy, distances between various anatomic landmarks were measured and compared to the temporal bone CT scan and the 3D model. The simulation allowed the surgical team to appreciate the child's unusual temporal bone anatomy as well as any challenges that might arise in the safety of the temporal bone laboratory, prior to actual surgery in the operating room (OR). There was minimal variability, in terms of absolute distance (mm) and relative distance (%), in measurements between anatomic landmarks obtained from the patient intra-operatively, the pre-operative CT scan and the 3D-printed models. Accurate 3D temporal bone models can be rapidly produced based on clinical CT scans for pre-operative simulation of specific challenging otologic cases in children, potentially reducing medical errors and improving patient safety. Copyright © 2015 Elsevier Ireland Ltd. All rights

  9. Listening to the ear

    Science.gov (United States)

    Shera, Christopher A.

    Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics-termed "tapering symmetry" after its geometric interpretation in simple models-that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical

  10. Ear, Hearing and Speech

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2000-01-01

    An introduction is given to the the anatomy and the function of the ear, basic psychoacoustic matters (hearing threshold, loudness, masking), the speech signal and speech intelligibility. The lecture note is written for the course: Fundamentals of Acoustics and Noise Control (51001)......An introduction is given to the the anatomy and the function of the ear, basic psychoacoustic matters (hearing threshold, loudness, masking), the speech signal and speech intelligibility. The lecture note is written for the course: Fundamentals of Acoustics and Noise Control (51001)...

  11. NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.

    Science.gov (United States)

    Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando

    2016-12-01

    Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.

  12. Preoperative planning of thoracic surgery with use of three-dimensional reconstruction, rapid prototyping, simulation and virtual navigation

    Science.gov (United States)

    Heuts, Samuel; Maessen, Jos G.

    2016-01-01

    For the past decades, surgeries have become more complex, due to the increasing age of the patient population referred for thoracic surgery, more complex pathology and the emergence of minimally invasive thoracic surgery. Together with the early detection of thoracic disease as a result of innovations in diagnostic possibilities and the paradigm shift to personalized medicine, preoperative planning is becoming an indispensable and crucial aspect of surgery. Several new techniques facilitating this paradigm shift have emerged. Pre-operative marking and staining of lesions are already a widely accepted method of preoperative planning in thoracic surgery. However, three-dimensional (3D) image reconstructions, virtual simulation and rapid prototyping (RP) are still in development phase. These new techniques are expected to become an important part of the standard work-up of patients undergoing thoracic surgery in the future. This review aims at graphically presenting and summarizing these new diagnostic and therapeutic tools PMID:29078505

  13. From Ear to Brain

    Science.gov (United States)

    Kimura, Doreen

    2011-01-01

    In this paper Doreen Kimura gives a personal history of the "right-ear effect" in dichotic listening. The focus is on the early ground-breaking papers, describing how she did the first dichotic listening studies relating the effects to brain asymmetry. The paper also gives a description of the visual half-field technique for lateralized stimulus…

  14. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  15. Seeing With the Ears

    NARCIS (Netherlands)

    Koenderink, Jan

    2015-01-01

    In recent talks, I mentioned how my artist friends often complain that their clients see with their ears. It recently dawned on me that nobody understood what I said, or—worse—got the wrong idea. The audience thinks of bionic devices (Proulx, Stoerig, Ludowig, & Knoll, 2008) or bat echo location

  16. Ear infection - acute

    Science.gov (United States)

    ... to the back of the throat. Normally, this tube drains fluid that is made in the middle ear. ... allows air to get in so fluids can drain more easily. Usually the tubes fall out by themselves. Those that don't ...

  17. Does previous open surgical experience have any influence on robotic surgery simulation exercises?

    Science.gov (United States)

    Cumpanas, Alin Adrian; Bardan, Razvan; Ferician, Ovidiu Catalin; Latcu, Silviu Constantin; Duta, Ciprian; Lazar, Fulger Octavian

    2017-12-01

    Within the last years, there has been a trend in many hospitals to switch their surgical activity from open/laparoscopic procedures to robotic surgery. Some open surgeons have been shifting their activity to robotic surgery. It is still unclear whether there is a transfer of open surgical skills to robotic ones. To evaluate whether such transfer of skills occurs and to identify which specific skills are more significantly transferred from the operative table to the console. Twenty-five volunteers were included in the study, divided into 2 groups: group A (15 participants) - medical students (without any surgical experience in open, laparoscopic or robotic surgery); and group B (10 participants) - surgeons with exclusively open surgical experience, without any previous laparoscopic or robotic experience. Participants were asked to complete 3 robotic simulator console exercises structured from the easiest one (Peg Board) to the toughest one (Sponge Suture). Overall scores for each exercise as well as specific metrics were compared between the two groups. There were no significant differences between overall scores of the two groups for the easiest task. Overall scores were better for group B as the exercises got more complex. For the intermediate and high-difficulty level exercises, most of the specific metrics were better for group B, with the exception of the working master space item. Our results suggest that the open surgical skills transfer to robotic skills, at least for the very beginning of the training process.

  18. Low-set ears and pinna abnormalities

    Science.gov (United States)

    Low-set ears; Microtia; "Lop" ear; Pinna abnormalities; Genetic defect - pinna; Congenital defect - pinna ... conditions: Abnormal folds or location of the pinna Low-set ears No opening to the ear canal ...

  19. Influence of videogames and musical instruments on performances at a simulator for robotic surgery.

    Science.gov (United States)

    Moglia, Andrea; Perrone, Vittorio; Ferrari, Vincenzo; Morelli, Luca; Boggi, Ugo; Ferrari, Mauro; Mosca, Franco; Cuschieri, Alfred

    2017-06-01

    To assess if exposure to videogames, musical instrument playing, or both influence the psychomotor skills level, assessed by a virtual reality simulator for robot-assisted surgery (RAS). A cohort of 57 medical students were recruited: playing musical instruments (group 1), videogames (group 2), both (group 3), and no activity (group 4); all students executed four exercises on a virtual simulator for RAS. Subjects from group 3 achieved the best performances on overall score: 527.09 ± 130.54 vs. 493.73 ± 108.88 (group 2), 472.72 ± 85.31 (group 1), and 403.13 ± 99.83 (group 4). Statistically significant differences (p videogames is higher than that in those practicing either one alone. The effect of videogames appears negligible in individuals playing the piano.

  20. Virtual vitreoretinal surgery: construction of a training programme on the Eyesi Surgical Simulator

    DEFF Research Database (Denmark)

    Vergmann, Anna Stage; Vestergaard, Anders Højslet; Grauslund, Jakob

    Purpose: The purpose of this study was to test the construct validity of a full virtual reality vitreoretinal training program at the Eyesi Surgical simulator. Design and methods: A virtual vitreoretinal training program was composed on the Eyesi Surgical simulator, software version 2.9.2 (VRmagic...... GmbH, Manheim, Germany). It was completed twice by three groups: Group 1: Twenty medical students Group 2: Ten ophthalmology residents Group 3: Five vitreoretinal surgeons The program consisted of six training modules (Figure 1): Navigation level 2 (Nav2) Forceps Training level 5 (ForT5) Bimanual...... developed a training program in virtual vitreoretinal surgery with construct validity for four out of six modules and for overall score. This makes the program a useful tool in the training of future vitreoretinal surgeons....

  1. Identification of New Tools to Predict Surgical Performance of Novices using a Plastic Surgery Simulator.

    Science.gov (United States)

    Kazan, Roy; Viezel-Mathieu, Alex; Cyr, Shantale; Hemmerling, Thomas M; Lin, Samuel J; Gilardino, Mirko S

    2018-04-09

    To identify new tools capable of predicting surgical performance of novices on an augmentation mammoplasty simulator. The pace of technical skills acquisition varies between residents and may necessitate more time than that allotted by residency training before reaching competence. Identifying applicants with superior innate technical abilities might shorten learning curves and the time to reach competence. The objective of this study is to identify new tools that could predict surgical performance of novices on a mammoplasty simulator. We recruited 14 medical students and recorded their performance in 2 skill-games: Mikado and Perplexus Epic, and in 2 video games: Star War Racer (Sony Playstation 3) and Super Monkey Ball 2 (Nintendo Wii). Then, each participant performed an augmentation mammoplasty procedure on a Mammoplasty Part-task Trainer, which allows the simulation of the essential steps of the procedure. The average age of participants was 25.4 years. Correlation studies showed significant association between Perplexus Epic, Star Wars Racer, Super Monkey Ball scores and the modified OSATS score with r s = 0.8491 (p 41 (p = 0.005), and r s = 0.7309 (p < 0.003), but not with the Mikado score r s = -0.0255 (p = 0.9). Linear regressions were strongest for Perplexus Epic and Super Monkey Ball scores with coefficients of determination of 0.59 and 0.55, respectively. A combined score (Perplexus/Super-Monkey-Ball) was computed and showed a significant correlation with the modified OSATS score having an r s = 0.8107 (p < 0.001) and R 2 = 0.75, respectively. This study identified a combination of skill games that correlated to better performance of novices on a surgical simulator. With refinement, such tools could serve to help screen plastic surgery applicants and identify those with higher surgical performance predictors. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. Virtual Reality-Based Simulators for Cranial Tumor Surgery: A Systematic Review.

    Science.gov (United States)

    Mazur, Travis; Mansour, Tarek R; Mugge, Luke; Medhkour, Azedine

    2018-02-01

    Virtual reality (VR) simulators have become useful tools in various fields of medicine. Prominent uses of VR technologies include assessment of physician skills and presurgical planning. VR has shown effectiveness in multiple surgical specialties, yet its use in neurosurgery remains limited. To examine all current literature on VR-based simulation for presurgical planning and training in cranial tumor surgeries and to assess the quality of these studies. PubMed and Embase were systematically searched to identify studies that used VR for presurgical planning and/or studies that investigated the use of VR as a training tool from inception to May 25, 2017. The initial search identified 1662 articles. Thirty-seven full-text articles were assessed for inclusion. Nine studies were included. These studies were subdivided into presurgical planning and training using VR. Prospects for VR are bright when surgical planning and skills training are considered. In terms of surgical planning, VR has noted and documented usefulness in the planning of cranial surgeries. Further, VR has been central to establishing reproducible benchmarks of performance in relation to cranial tumor resection, which are helpful not only in showing face and construct validity but also in enhancing neurosurgical training in a way not previously examined. Although additional studies are needed to better delineate the precise role of VR in each of these capacities, these studies stand to show the usefulness of VR in the neurosurgery and highlight the need for further investigation. Published by Elsevier Inc.

  3. Ramifications of single-port laparoscopic surgery: measuring differences in task performance using simulation.

    Science.gov (United States)

    Conway, Nathan E; Romanelli, John R; Bush, Ron W; Seymour, Neal E

    2014-02-01

    Single-port laparoscopic surgery imposes unique psychomotor challenges. We used surgical simulation to define performance differences between surgeons with and without single-port clinical experience and examined whether a short course of training resulted in improved performance. Study participants were assigned to 3 groups: resident group (RES), experienced laparoscopic surgeons with (SP) and without (LAP) prior single-port laparoscopic experience. Participants performed the Fundamentals of Laparoscopic Surgery precision cutting task on a ProMIS trainer through conventional ports or with articulating instruments via a SILS Port (Covidien, Inc). Two iterations of each method were performed. Then, 6 residents performed 10 successive single-port iterations to assess the effect of practice on task performance. The SP group had faster task times for both laparoscopic (P = .0486) and single-port (P = .0238) methods. The LAP group had longer path lengths for the single-port task than for the laparoscopic task (P = .03). The RES group was slower (P = .0019), with longer path length (P = .0010) but with greater smoothness (P = .0186) on the single-port task than the conventional laparoscopic task. Resident performance task time (P = .005) and smoothness (P = .045) improved with successive iterations. Our data show that surgeons with clinical single-port surgery experience perform a simulated single-port surgical task better than inexperienced single-port surgeons. Furthermore, this performance is comparable to that achieved with conventional laparoscopic techniques. Performance of residents declined dramatically when confronted with the challenges of the single-port task but improved with practice. These results suggest a role for lab-based single-port training.

  4. Better Ear Health

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  5. Ears and Altitude

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  6. Comparison of real and computer-simulated outcomes of LASIK refractive surgery

    Science.gov (United States)

    Cano, Daniel; Barbero, Sergio; Marcos, Susana

    2004-06-01

    Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were compared with real postoperative outcomes. Standard LASIK refractive surgery for myopia increased corneal asphericity and spherical aberration. Computations with the theoretical Munnerlyn ablation pattern did not increase the corneal asphericity and spherical aberration. The theoretical parabolic pattern induced a slight increase of asphericity and spherical aberration, explaining only 40% of the clinically found increase. The theoretical biconic pattern controlled corneal spherical aberration. Computations showed that the theoretical customized pattern can correct high-order asymmetric aberrations. Simulations of changes in efficiency due to reflection and nonnormal incidence of the laser light showed a further increase in corneal asphericity. Consideration of these effects with a parabolic pattern accounts for 70% of the clinical increase in asphericity.

  7. Computed tomography of middle ear cholesteatomas without tympanic membrane perforation

    International Nuclear Information System (INIS)

    Ettorre, G.C.

    1991-01-01

    The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue masses in the absence of bone alterations

  8. Images created in a model eye during simulated cataract surgery can be the basis for images perceived by patients during cataract surgery

    Science.gov (United States)

    Inoue, M; Uchida, A; Shinoda, K; Taira, Y; Noda, T; Ohnuma, K; Bissen-Miyajima, H; Hirakata, A

    2014-01-01

    Purpose To evaluate the images created in a model eye during simulated cataract surgery. Patients and methods This study was conducted as a laboratory investigation and interventional case series. An artificial opaque lens, a clear intraocular lens (IOL), or an irrigation/aspiration (I/A) tip was inserted into the ‘anterior chamber' of a model eye with the frosted posterior surface corresponding to the retina. Video images were recorded of the posterior surface of the model eye from the rear during simulated cataract surgery. The video clips were shown to 20 patients before cataract surgery, and the similarity of their visual perceptions to these images was evaluated postoperatively. Results The images of the moving lens fragments and I/A tip and the insertion of the IOL were seen from the rear. The image through the opaque lens and the IOL without moving objects was the light of the surgical microscope from the rear. However, when the microscope light was turned off after IOL insertion, the images of the microscope and operating room were observed by the room illumination from the rear. Seventy percent of the patients answered that the visual perceptions of moving lens fragments were similar to the video clips and 55% reported similarity with the IOL insertion. Eighty percent of the patients recommended that patients watch the video clip before their scheduled cataract surgery. Conclusions The patients' visual perceptions during cataract surgery can be reproduced in the model eye. Watching the video images preoperatively may help relax the patients during surgery. PMID:24788007

  9. Modeling Analysis of Biomechanical Changes of Middle Ear and Cochlea in Otitis Media

    Science.gov (United States)

    Gan, Rong Z.; Zhang, Xiangming; Guan, Xiying

    2011-11-01

    A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea.

  10. A practical 3D printed simulator for endoscopic endonasal transsphenoidal surgery to improve basic operational skills.

    Science.gov (United States)

    Wen, Guodao; Cong, ZiXiang; Liu, KaiDong; Tang, Chao; Zhong, Chunyu; Li, Liwen; Dai, XuJie; Ma, Chiyuan

    2016-06-01

    We aimed to present a practical three-dimensional (3D) printed simulator to comprehensively and effectively accelerate the learning curve of endoscopic endonasal transsphenoidal surgery (EETS). The 3D printed simulator consists of three parts: (1) skull frame, (2) the nasal passage and the nasal alar of the face, and (3) a modified sella turcica. We aimed to improve three basic operational skills of surgeons: drilling, curetting, and aspirating. Eighteen neurosurgeons and five post-graduates were recruited and consented for the training. For trainees, (1) as the training progressed, the scores increased gradually, (2) a significant increase in the average scores was observed in the tenth training compared to the first training, and (3) there is a significant decrease in trainee variability in the shortening of the gap. The 18 neurosurgeons were divided into three groups: experts, assistants, and observers. For all three basic operations, (1) the average score of experts was obviously higher than that of the assistants, observers, and trainees' tenth training and (2) the average scores of assistants and observers were obviously higher than that of trainees' first training. A significant high in the average score between the assistants and the observers was seen for aspirating, but not for drilling or curetting. For curetting and aspirating, the tenth training average score of trainees was obviously higher than that of assistants and observers. This 3D printed simulator allows different endoscopic basic operations to be simulated and improves the EETS techniques of surgeons. We believed it to be a practical, simple, and low-cost simulator.

  11. Simulation-Based Laparoscopic Surgery Crisis Resource Management Training-Predicting Technical and Nontechnical Skills.

    Science.gov (United States)

    Goldenberg, Mitchell G; Fok, Kai H; Ordon, Michael; Pace, Kenneth T; Lee, Jason Y

    2017-12-19

    To develop a unique simulation-based assessment using a laparoscopic inferior vena cava (IVC) injury scenario that allows for the safe assessment of urology resident's technical and nontechnical skills, and investigate the effect of personality traits performance in a surgical crisis. Urology residents from our institution were recruited to participate in a simulation-based training laparoscopic nephrectomy exercise. Residents completed demographic and multidimensional personality questionnaires and were instructed to play the role of staff urologist. A vasovagal response to pneumoperitoneum and an IVC injury event were scripted into the scenario. Technical and nontechnical skills were assessed by expert laparoscopic surgeons using validated tools (task checklist, GOALS, and NOTSS). Ten junior and five senior urology residents participated. Five residents were unable to complete the exercise safely. Senior residents outperformed juniors on technical (checklist score 15.1 vs 9.9, p Technical performance scores correlated with NOTSS scores (p technical performance (p technical score (p = 0.03) and pass/fail rating (p = 0.04). Resident level of training and laparoscopic experience correlated with technical performance during a simulation-based laparoscopic IVC injury crisis management scenario, as well as multiple domains of nontechnical performance. Personality traits of our surgical residents are similar and did not predict technical skill. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. [Accuracy of morphological simulation for orthognatic surgery. Assessment of a 3D image fusion software.

    Science.gov (United States)

    Terzic, A; Schouman, T; Scolozzi, P

    2013-08-06

    The CT/CBCT data allows for 3D reconstruction of skeletal and untextured soft tissue volume. 3D stereophotogrammetry technology has strongly improved the quality of facial soft tissue surface texture. The combination of these two technologies allows for an accurate and complete reconstruction. The 3D virtual head may be used for orthognatic surgical planning, virtual surgery, and morphological simulation obtained with a software dedicated to the fusion of 3D photogrammetric and radiological images. The imaging material include: a multi-slice CT scan or broad field CBCT scan, a 3D photogrammetric camera. The operative image processing protocol includes the following steps: 1) pre- and postoperative CT/CBCT scan and 3D photogrammetric image acquisition; 2) 3D image segmentation and fusion of untextured CT/CBCT skin with the preoperative textured facial soft tissue surface of the 3D photogrammetric scan; 3) image fusion of the pre- and postoperative CT/CBCT data set virtual osteotomies, and 3D photogrammetric soft tissue virtual simulation; 4) fusion of virtual simulated 3D photogrammetric and real postoperative images, and assessment of accuracy using a color-coded scale to measure the differences between the two surfaces. Copyright © 2013. Published by Elsevier Masson SAS.

  13. High-fidelity haptic and visual rendering for patient-specific simulation of temporal bone surgery.

    Science.gov (United States)

    Chan, Sonny; Li, Peter; Locketz, Garrett; Salisbury, Kenneth; Blevins, Nikolas H

    2016-12-01

    Medical imaging techniques provide a wealth of information for surgical preparation, but it is still often the case that surgeons are examining three-dimensional pre-operative image data as a series of two-dimensional images. With recent advances in visual computing and interactive technologies, there is much opportunity to provide surgeons an ability to actively manipulate and interpret digital image data in a surgically meaningful way. This article describes the design and initial evaluation of a virtual surgical environment that supports patient-specific simulation of temporal bone surgery using pre-operative medical image data. Computational methods are presented that enable six degree-of-freedom haptic feedback during manipulation, and that simulate virtual dissection according to the mechanical principles of orthogonal cutting and abrasive wear. A highly efficient direct volume renderer simultaneously provides high-fidelity visual feedback during surgical manipulation of the virtual anatomy. The resulting virtual surgical environment was assessed by evaluating its ability to replicate findings in the operating room, using pre-operative imaging of the same patient. Correspondences between surgical exposure, anatomical features, and the locations of pathology were readily observed when comparing intra-operative video with the simulation, indicating the predictive ability of the virtual surgical environment.

  14. A Novel Haptic Interactive Approach to Simulation of Surgery Cutting Based on Mesh and Meshless Models

    Science.gov (United States)

    Liu, Peter X.; Lai, Pinhua; Xu, Shaoping; Zou, Yanni

    2018-01-01

    In the present work, the majority of implemented virtual surgery simulation systems have been based on either a mesh or meshless strategy with regard to soft tissue modelling. To take full advantage of the mesh and meshless models, a novel coupled soft tissue cutting model is proposed. Specifically, the reconstructed virtual soft tissue consists of two essential components. One is associated with surface mesh that is convenient for surface rendering and the other with internal meshless point elements that is used to calculate the force feedback during cutting. To combine two components in a seamless way, virtual points are introduced. During the simulation of cutting, the Bezier curve is used to characterize smooth and vivid incision on the surface mesh. At the same time, the deformation of internal soft tissue caused by cutting operation can be treated as displacements of the internal point elements. Furthermore, we discussed and proved the stability and convergence of the proposed approach theoretically. The real biomechanical tests verified the validity of the introduced model. And the simulation experiments show that the proposed approach offers high computational efficiency and good visual effect, enabling cutting of soft tissue with high stability. PMID:29850006

  15. Outcomes of a virtual-reality simulator-training programme on basic surgical skills in robot-assisted laparoscopic surgery.

    Science.gov (United States)

    Phé, Véronique; Cattarino, Susanna; Parra, Jérôme; Bitker, Marc-Olivier; Ambrogi, Vanina; Vaessen, Christophe; Rouprêt, Morgan

    2017-06-01

    The utility of the virtual-reality robotic simulator in training programmes has not been clearly evaluated. Our aim was to evaluate the impact of a virtual-reality robotic simulator-training programme on basic surgical skills. A simulator-training programme in robotic surgery, using the da Vinci Skills Simulator, was evaluated in a population including junior and seasoned surgeons, and non-physicians. Their performances on robotic dots and suturing-skin pod platforms before and after virtual-simulation training were rated anonymously by surgeons experienced in robotics. 39 participants were enrolled: 14 medical students and residents in surgery, 14 seasoned surgeons, 11 non-physicians. Junior and seasoned surgeons' performances on platforms were not significantly improved after virtual-reality robotic simulation in any of the skill domains, in contrast to non-physicians. The benefits of virtual-reality simulator training on several tasks to basic skills in robotic surgery were not obvious among surgeons in our initial and early experience with the simulator. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Does computer-aided surgical simulation improve efficiency in bimaxillary orthognathic surgery?

    Science.gov (United States)

    Schwartz, H C

    2014-05-01

    The purpose of this study was to compare the efficiency of bimaxillary orthognathic surgery using computer-aided surgical simulation (CASS), with cases planned using traditional methods. Total doctor time was used to measure efficiency. While costs vary widely in different localities and in different health schemes, time is a valuable and limited resource everywhere. For this reason, total doctor time is a more useful measure of efficiency than is cost. Even though we use CASS primarily for planning more complex cases at the present time, this study showed an average saving of 60min for each case. In the context of a department that performs 200 bimaxillary cases each year, this would represent a saving of 25 days of doctor time, if applied to every case. It is concluded that CASS offers great potential for improving efficiency when used in the planning of bimaxillary orthognathic surgery. It saves significant doctor time that can be applied to additional surgical work. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. In-the-Ear Spiral Monopole Antenna for Hearing Instruments

    DEFF Research Database (Denmark)

    Kammersgaard, Nikolaj Peter Iversen; Kvist, Søren Helstrup; Thaysen, Jesper

    2014-01-01

    A novel in-the-ear (ITE) antenna solution for hearing instruments that operates at 2.45 GHz is presented. The antenna consists of a quarter wave monopole and a ground plane that are placed in the ear. The simulated path gain | S 21 |is − 86 dB and the measured path gain is − 80 dB. Simulations an...... and measurements show that the antenna covers the entire 2.40 – 2.48 GHz industrial, scientific and medical (ISM) band. It is the first ever ITE-antenna solution that demonstrates the possibility of establishing an ear-to-ear link by using a standard Bluetooth chip...

  18. Automated outcome scoring in a virtual reality simulator for endodontic surgery.

    Science.gov (United States)

    Yin, Myat Su; Haddawy, Peter; Suebnukarn, Siriwan; Rhienmora, Phattanapon

    2018-01-01

    We address the problem of automated outcome assessment in a virtual reality (VR) simulator for endodontic surgery. Outcome assessment is an essential component of any system that provides formative feedback, which requires assessing the outcome, relating it to the procedure, and communicating in a language natural to dental students. This study takes a first step toward automated generation of such comprehensive feedback. Virtual reference templates are computed based on tooth anatomy and the outcome is assessed with a 3D score cube volume which consists of voxel-level non-linear weighted scores based on the templates. The detailed scores are transformed into standard scoring language used by dental schools. The system was evaluated on fifteen outcome samples that contained optimal results and those with errors including perforation of the walls, floor, and both, as well as various combinations of major and minor over and under drilling errors. Five endodontists who had professional training and varying levels of experiences in root canal treatment participated as raters in the experiment. Results from evaluation of our system with expert endodontists show a high degree of agreement with expert scores (information based measure of disagreement 0.04-0.21). At the same time they show some disagreement among human expert scores, reflecting the subjective nature of human outcome scoring. The discriminatory power of the AOS scores analyzed with three grade tiers (A, B, C) using the area under the receiver operating characteristic curve (AUC). The AUC values are generally highest for the {AB: C} cutoff which is cutoff at the boundary between clinically acceptable (B) and clinically unacceptable (C) grades. The objective consistency of computed scores and high degree of agreement with experts make the proposed system a promising addition to existing VR simulators. The translation of detailed level scores into terminology commonly used in dental surgery supports natural

  19. Identifying Opportunities for Virtual Reality Simulation in Surgical Education: A Review of the Proceedings from the Innovation, Design, and Emerging Alliances in Surgery (IDEAS) Conference: VR Surgery

    Science.gov (United States)

    Olasky, Jaisa; Sankaranarayanan, Ganesh; Seymour, Neal E.; Magee, J. Harvey; Enquobahrie, Andinet; Lin, Ming C.; Aggarwal, Rajesh; Brunt, L. Michael; Schwaitzberg, Steven D.; Cao, Caroline G. L.; De, Suvranu; Jones, Daniel B.

    2015-01-01

    Objectives To conduct a review of the state of virtual reality (VR) simulation technology, to identify areas of surgical education that have the greatest potential to benefit from it, and to identify challenges to implementation. Background Data Simulation is an increasingly important part of surgical training. VR is a developing platform for using simulation to teach technical skills, behavioral skills, and entire procedures to trainees and practicing surgeons worldwide. Questions exist regarding the science behind the technology and most effective usage of VR simulation. A symposium was held to address these issues. Methods Engineers, educators, and surgeons held a conference in November 2013 both to review the background science behind simulation technology and to create guidelines for its use in teaching and credentialing trainees and surgeons in practice. Results Several technologic challenges were identified that must be overcome in order for VR simulation to be useful in surgery. Specific areas of student, resident, and practicing surgeon training and testing that would likely benefit from VR were identified: technical skills, team training and decision-making skills, and patient safety, such as in use of electrosurgical equipment. Conclusions VR simulation has the potential to become an essential piece of surgical education curriculum but depends heavily on the establishment of an agreed upon set of goals. Researchers and clinicians must collaborate to allocate funding toward projects that help achieve these goals. The recommendations outlined here should guide further study and implementation of VR simulation. PMID:25925424

  20. Identifying Opportunities for Virtual Reality Simulation in Surgical Education: A Review of the Proceedings from the Innovation, Design, and Emerging Alliances in Surgery (IDEAS) Conference: VR Surgery.

    Science.gov (United States)

    Olasky, Jaisa; Sankaranarayanan, Ganesh; Seymour, Neal E; Magee, J Harvey; Enquobahrie, Andinet; Lin, Ming C; Aggarwal, Rajesh; Brunt, L Michael; Schwaitzberg, Steven D; Cao, Caroline G L; De, Suvranu; Jones, Daniel B

    2015-10-01

    To conduct a review of the state of virtual reality (VR) simulation technology, to identify areas of surgical education that have the greatest potential to benefit from it, and to identify challenges to implementation. Simulation is an increasingly important part of surgical training. VR is a developing platform for using simulation to teach technical skills, behavioral skills, and entire procedures to trainees and practicing surgeons worldwide. Questions exist regarding the science behind the technology and most effective usage of VR simulation. A symposium was held to address these issues. Engineers, educators, and surgeons held a conference in November 2013 both to review the background science behind simulation technology and to create guidelines for its use in teaching and credentialing trainees and surgeons in practice. Several technologic challenges were identified that must be overcome in order for VR simulation to be useful in surgery. Specific areas of student, resident, and practicing surgeon training and testing that would likely benefit from VR were identified: technical skills, team training and decision-making skills, and patient safety, such as in use of electrosurgical equipment. VR simulation has the potential to become an essential piece of surgical education curriculum but depends heavily on the establishment of an agreed upon set of goals. Researchers and clinicians must collaborate to allocate funding toward projects that help achieve these goals. The recommendations outlined here should guide further study and implementation of VR simulation. © The Author(s) 2015.

  1. A cost effective and high fidelity fluoroscopy simulator using the Image-Guided Surgery Toolkit (IGSTK)

    Science.gov (United States)

    Gong, Ren Hui; Jenkins, Brad; Sze, Raymond W.; Yaniv, Ziv

    2014-03-01

    The skills required for obtaining informative x-ray fluoroscopy images are currently acquired while trainees provide clinical care. As a consequence, trainees and patients are exposed to higher doses of radiation. Use of simulation has the potential to reduce this radiation exposure by enabling trainees to improve their skills in a safe environment prior to treating patients. We describe a low cost, high fidelity, fluoroscopy simulation system. Our system enables operators to practice their skills using the clinical device and simulated x-rays of a virtual patient. The patient is represented using a set of temporal Computed Tomography (CT) images, corresponding to the underlying dynamic processes. Simulated x-ray images, digitally reconstructed radiographs (DRRs), are generated from the CTs using ray-casting with customizable machine specific imaging parameters. To establish the spatial relationship between the CT and the fluoroscopy device, the CT is virtually attached to a patient phantom and a web camera is used to track the phantom's pose. The camera is mounted on the fluoroscope's intensifier and the relationship between it and the x-ray source is obtained via calibration. To control image acquisition the operator moves the fluoroscope as in normal operation mode. Control of zoom, collimation and image save is done using a keypad mounted alongside the device's control panel. Implementation is based on the Image-Guided Surgery Toolkit (IGSTK), and the use of the graphics processing unit (GPU) for accelerated image generation. Our system was evaluated by 11 clinicians and was found to be sufficiently realistic for training purposes.

  2. Radiographic appearance of the middle ear after ventral bulla osteotomy in five dogs with otitis media

    International Nuclear Information System (INIS)

    Holt, D.E.; Walker, L.

    1997-01-01

    Radiographs of the middle ear were made in five dogs 60 to 78 months after ventral bulla osteotomy was performed to treat otitis media. The clinical results of surgery were considered satisfactory in four dogs and unsatisfactory in one. In 4 dogs with satisfactory results, radiographs demonstrated complete reformation of the bulla in 3 operated middle ears (3 dogs), with partial bulla reformation in the three middle ears (3 dogs). Radiographs in one dog with unsatisfactory results showed complete bulla reformation with no increase in lumen opacity. The proliferative bony response obliterating the middle ear previously reported in normal dogs after ventral bulla osteotomy was not seen in any of these patients

  3. Otologic Surgery Training in a Rural Ethiopian Community

    African Journals Online (AJOL)

    Despite the large number of people needing ear surgery on the African continent, otologic (ear) surgeries are few. However, safe and effective otologic surgeries are ... and Egypt and by residents and recent graduates from the ENT department at Addis Ababa .... South African Medical. Journal = Suid-Afrikaanse Tydskrif Vir ...

  4. Three dimensional computed tomography lung modeling is useful in simulation and navigation of lung cancer surgery.

    Science.gov (United States)

    Ikeda, Norihiko; Yoshimura, Akinobu; Hagiwara, Masaru; Akata, Soichi; Saji, Hisashi

    2013-01-01

    The number of minimally invasive operations, such as video-assisted thoracoscopic surgery (VATS) lobectomy or segmentectomy, has enormously increased in recent years. These operations require extreme knowledge of the anatomy of pulmonary vessels and bronchi in each patient, and surgeons must carefully dissect the branches of pulmonary vessels during operation. Thus, foreknowledge of the anatomy of each patient would greatly contribute to the safety and accuracy of the operation. The development of multi-detector computed tomography (MDCT) has promoted three dimensional (3D) images of lung structures. It is possible to see the vascular and bronchial structures from the view of the operator; therefore, it is employed for preoperative simulation as well as navigation during operation. Due to advances in software, even small vessels can be accurately imaged, which is useful in performing segmentectomy. Surgical simulation and navigation systems based on high quality 3D lung modeling, including vascular and bronchial structures, can be used routinely to enhance the safety operation, education of junior staff, as well as providing a greater sense of security to the operators.

  5. Recent advances in 3D computed tomography techniques for simulation and navigation in hepatobiliary pancreatic surgery.

    Science.gov (United States)

    Uchida, Masafumi

    2014-04-01

    A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  6. Training and assessment of psychomotor skills for performing laparoscopic surgery using BEST-IRIS virtual reality training simulator.

    Science.gov (United States)

    Makam, Ramesh; Rajan, C S; Brendon, Tulip; Shreedhar, V; Saleem, K; Shrivastava, Sangeeta; Sudarshan, R; Naidu, Prakash

    2004-01-01

    In this article, we present the results of a pilot study that examined the performance of people training on a Virtual Reality based BEST-IRIS Laparoscopic Surgery Training Simulator. The performance of experienced surgeons was examined and compared to the performance of residents. The purpose of this study is to validate the BEST-IRIS training simulator. It appeared to be a useful training and assessment tool.

  7. Face and Construct Validity of the SimSurgery SEP VR Simulator for Salpingectomy in Case of Ectopic Pregnancy

    NARCIS (Netherlands)

    Hessel, M.; Buzink, S.N.; Schoot, B.C.; Jakimowicz, J.J.

    2012-01-01

    Objective: To secure patient safety, skills needed for laparoscopy are preferably obtained in a non-patient setting. Therefore, we assessed face and construct validity of performance of a salpingectomy in case of ectopic pregnancy on the SimSurgery SEP VR simulator. Materials and Methods: Fifteen

  8. Naturopathic treatment for ear pain in children.

    Science.gov (United States)

    Sarrell, E Michael; Cohen, Herman Avner; Kahan, Ernesto

    2003-05-01

    included in the study and recorded all of the data. The presence or absence of ear pain was assessed over 3 days with a visual analog scale. Ear pain was assessed by a specially devised observational instrument based on previous reports. One side of the instrument consisted of a linear numbered scale, from 1 (no pain) to 10 (worst possible pain), and a corresponding color scale, ranging from blue to dark red. The reverse side contained a scale of 5 facial expressions, ranging from broad smile (no pain) to a sad and crying face (worst possible pain), and a corresponding color scale, ranging from blue to dark red. There were no significant between-group differences in patient age or gender, degree of fever, main symptoms, associated symptoms, and severity or laterality of acute otitis media. Each group had a statistically significant improvement in ear pain over the course of the 3 days. Patients who were given ear drops alone had a better response than patients who were given ear drops together with amoxicillin. Results were better in the NHED group than in the controls. Nevertheless, the findings indicated that the pain was mostly (80%) self-limited and could be explained simply by the time elapsed. The American Academy of Otolaryngology-Head and Neck Surgery guidelines recommend topical medications as the first line of treatment for ear pain in the absence of systemic infection or serious underlying disease. Because no evidence was found that systemic antibiotics alone improved treatment outcome, if antibiotics do not change the natural course of otitis media, then the main goal of treatment, as in the present study, should be to alleviate the ear pain. The alternative, naturopathic herbal extract medications, may offer many new possibilities in the management of ear pain associated with AOM. Primary care physicians should be aware that at least 10% of their patients may have tried 1 or more forms of alternative/complementary medicine before presenting for consultation

  9. Internet-Based Digital Simulation for Cleft Surgery Education: A 5-Year Assessment of Demographics, Usage, and Global Effect.

    Science.gov (United States)

    Kantar, Rami S; Plana, Natalie M; Cutting, Court B; Diaz-Siso, Jesus Rodrigo; Flores, Roberto L

    2018-01-29

    In October 2012, a freely available, internet-based cleft simulator was created in partnership between academic, nonprofit, and industry sectors. The purpose of this educational resource was to address global disparities in cleft surgery education. This report assesses demographics, usage, and global effect of our simulator, in its fifth year since inception. Evaluate the global effect, usage, and demographics of an internet-based educational digital simulation cleft surgery software. Simulator modules, available in five languages demonstrate surgical anatomy, markings, detailed procedures, and intraoperative footage to supplement digital animation. Available data regarding number of users, sessions, countries reached, and content access were recorded. Surveys evaluating the demographic characteristics of registered users and simulator use were collected by direct e-mail. The total number of simulator new and active users reached 2865 and 4086 in June 2017, respectively. By June 2017, users from 136 countries had accessed the simulator. From 2015 to 2017, the number of sessions was 11,176 with a monthly average of 399.0 ± 190.0. Developing countries accounted for 35% of sessions and the average session duration was 9.0 ± 7.3 minutes. This yields a total simulator screen time of 100,584 minutes (1676 hours). Most survey respondents were surgeons or trainees (87%) specializing in plastic, maxillofacial, or general surgery (89%). Most users found the simulator to be useful (88%), at least equivalent or more useful than other resources (83%), and used it for teaching (58%). Our internet-based interactive cleft surgery platform reaches its intended target audience, is not restricted by socioeconomic barriers to access, and is judged to be useful by surgeons. More than 4000 active users have been reached since inception. The total screen time over approximately 2 years exceeded 1600 hours. This suggests that future surgical simulators of this kind may be sustainable by

  10. Real-time simulation of soft tissue deformation and electrocautery procedures in laparoscopic rectal cancer radical surgery.

    Science.gov (United States)

    Sui, Yuan; Pan, Jun J; Qin, Hong; Liu, Hao; Lu, Yun

    2017-12-01

    Laparoscopic surgery (LS), also referred to as minimally invasive surgery, is a modern surgical technique which is widely applied. The fulcrum effect makes LS a non-intuitive motor skill with a steep learning curve. A hybrid model of tetrahedrons and a multi-layer triangular mesh are constructed to simulate the deformable behavior of the rectum and surrounding tissues in the Position-Based Dynamics (PBD) framework. A heat-conduction based electric-burn technique is employed to simulate the electrocautery procedure. The simulator has been applied for laparoscopic rectum cancer surgery training. From the experimental results, trainees can operate in real time with high degrees of stability and fidelity. A preliminary study was performed to evaluate the realism and usefulness. This prototype simulator has been tested and verified by colorectal surgeons through a pilot study. They believed both the visual and the haptic performance of the simulation are realistic and helpful to enhance laparoscopic skills. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Autoimmune Inner Ear Disease

    Science.gov (United States)

    ... system. AIED Research A multi-institutional clinical study, Otolaryngology Clinical Trial Cooperative Group (OCTCG) co-sponsored by the NIH and the American Academy of Otolaryngology-Head and Neck Surgery Foundation, is being conducted ...

  12. Clinical Efficacy of Simulated Vitreoretinal Surgery to Prepare Surgeons for the Upcoming Intervention in the Operating Room.

    Science.gov (United States)

    Deuchler, Svenja; Wagner, Clemens; Singh, Pankaj; Müller, Michael; Al-Dwairi, Rami; Benjilali, Rachid; Schill, Markus; Ackermann, Hanns; Bon, Dimitra; Kohnen, Thomas; Schoene, Benjamin; Koss, Michael; Koch, Frank

    2016-01-01

    To evaluate the efficacy of the virtual reality training simulator Eyesi to prepare surgeons for performing pars plana vitrectomies and its potential to predict the surgeons' performance. In a preparation phase, four participating vitreoretinal surgeons performed repeated simulator training with predefined tasks. If a surgeon was assigned to perform a vitrectomy for the management of complex retinal detachment after a surgical break of at least 60 hours it was randomly decided whether a warmup training on the simulator was required (n = 9) or not (n = 12). Performance at the simulator was measured using the built-in scoring metrics. The surgical performance was determined by two blinded observers who analyzed the video-recorded interventions. One of them repeated the analysis to check for intra-observer consistency. The surgical performance of the interventions with and without simulator training was compared. In addition, for the surgeries with simulator training, the simulator performance was compared to the performance in the operating room. Comparing each surgeon's performance with and without warmup trainingshowed a significant effect of warmup training onto the final outcome in the operating room. For the surgeries that were preceeded by the warmup procedure, the performance at the simulator was compared with the operating room performance. We found that there is a significant relation. The governing factor of low scores in the simulator were iatrogenic retinal holes, bleedings and lens damage. Surgeons who caused minor damage in the simulation also performed well in the operating room. Despite the large variation of conditions, the effect of a warmup training as well as a relation between the performance at the simulator and in the operating room was found with statistical significance. Simulator training is able to serve as a warmup to increase the average performance.

  13. Clinical Efficacy of Simulated Vitreoretinal Surgery to Prepare Surgeons for the Upcoming Intervention in the Operating Room.

    Directory of Open Access Journals (Sweden)

    Svenja Deuchler

    Full Text Available To evaluate the efficacy of the virtual reality training simulator Eyesi to prepare surgeons for performing pars plana vitrectomies and its potential to predict the surgeons' performance.In a preparation phase, four participating vitreoretinal surgeons performed repeated simulator training with predefined tasks. If a surgeon was assigned to perform a vitrectomy for the management of complex retinal detachment after a surgical break of at least 60 hours it was randomly decided whether a warmup training on the simulator was required (n = 9 or not (n = 12. Performance at the simulator was measured using the built-in scoring metrics. The surgical performance was determined by two blinded observers who analyzed the video-recorded interventions. One of them repeated the analysis to check for intra-observer consistency. The surgical performance of the interventions with and without simulator training was compared. In addition, for the surgeries with simulator training, the simulator performance was compared to the performance in the operating room.Comparing each surgeon's performance with and without warmup trainingshowed a significant effect of warmup training onto the final outcome in the operating room. For the surgeries that were preceeded by the warmup procedure, the performance at the simulator was compared with the operating room performance. We found that there is a significant relation. The governing factor of low scores in the simulator were iatrogenic retinal holes, bleedings and lens damage. Surgeons who caused minor damage in the simulation also performed well in the operating room.Despite the large variation of conditions, the effect of a warmup training as well as a relation between the performance at the simulator and in the operating room was found with statistical significance. Simulator training is able to serve as a warmup to increase the average performance.

  14. Face and content validity of Xperience™ Team Trainer: bed-side assistant training simulator for robotic surgery.

    Science.gov (United States)

    Sessa, Luca; Perrenot, Cyril; Xu, Song; Hubert, Jacques; Bresler, Laurent; Brunaud, Laurent; Perez, Manuela

    2018-03-01

    In robotic surgery, the coordination between the console-side surgeon and bed-side assistant is crucial, more than in standard surgery or laparoscopy where the surgical team works in close contact. Xperience™ Team Trainer (XTT) is a new optional component for the dv-Trainer ® platform and simulates the patient-side working environment. We present preliminary results for face, content, and the workload imposed regarding the use of the XTT virtual reality platform for the psychomotor and communication skills training of the bed-side assistant in robot-assisted surgery. Participants were categorized into "Beginners" and "Experts". They tested a series of exercises (Pick & Place Laparoscopic Demo, Pick & Place 2 and Team Match Board 1) and completed face validity questionnaires. "Experts" assessed content validity on another questionnaire. All the participants completed a NASA Task Load Index questionnaire to assess the workload imposed by XTT. Twenty-one consenting participants were included (12 "Beginners" and 9 "Experts"). XTT was shown to possess face and content validity, as evidenced by the rankings given on the simulator's ease of use and realism parameters and on the simulator's usefulness for training. Eight out of nine "Experts" judged the visualization of metrics after the exercises useful. However, face validity has shown some weaknesses regarding interactions and instruments. Reasonable workload parameters were registered. XTT demonstrated excellent face and content validity with acceptable workload parameters. XTT could become a useful tool for robotic surgery team training.

  15. Student perceptions of a simulation-based flipped classroom for the surgery clerkship: A mixed-methods study.

    Science.gov (United States)

    Liebert, Cara A; Mazer, Laura; Bereknyei Merrell, Sylvia; Lin, Dana T; Lau, James N

    2016-09-01

    The flipped classroom, a blended learning paradigm that uses pre-session online videos reinforced with interactive sessions, has been proposed as an alternative to traditional lectures. This article investigates medical students' perceptions of a simulation-based, flipped classroom for the surgery clerkship and suggests best practices for implementation in this setting. A prospective cohort of students (n = 89), who were enrolled in the surgery clerkship during a 1-year period, was taught via a simulation-based, flipped classroom approach. Students completed an anonymous, end-of-clerkship survey regarding their perceptions of the curriculum. Quantitative analysis of Likert responses and qualitative analysis of narrative responses were performed. Students' perceptions of the curriculum were positive, with 90% rating it excellent or outstanding. The majority reported the curriculum should be continued (95%) and applied to other clerkships (84%). The component received most favorably by the students was the simulation-based skill sessions. Students rated the effectiveness of the Khan Academy-style videos the highest compared with other video formats (P flipped classroom in the surgery clerkship were overwhelmingly positive. The flipped classroom approach can be applied successfully in a surgery clerkship setting and may offer additional benefits compared with traditional lecture-based curricula. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Pressure difference receiving ears

    DEFF Research Database (Denmark)

    Michelsen, Axel; Larsen, Ole Næsbye

    2007-01-01

    Directional sound receivers are useful for locating sound sources, and they can also partly compensate for the signal degradations caused by noise and reverberations. Ears may become inherently directional if sound can reach both surfaces of the eardrum. Attempts to understand the physics...... of the eardrum. The mere existence of sound transmission to the inner surface does not ensure a useful directional hearing, since a proper amplitude and phase relationship must exist between the sounds acting on the two surfaces of the eardrum. The gain of the sound pathway must match the amplitude and phase...... of the sounds at the outer surfaces of the eardrums, which are determined by diffraction and by the arrival time of the sound, that is by the size and shape of the animal and by the frequency of sound. Many users of hearing aids do not obtain a satisfactory improvement of their ability to localize sound sources...

  17. The use of in-situ simulation to improve safety in the plastic surgery office: a feasibility study.

    Science.gov (United States)

    Shapiro, Fred E; Pawlowski, John B; Rosenberg, Noah M; Liu, Xiaoxia; Feinstein, David M; Urman, Richard D

    2014-01-01

    Simulation-based interventions and education can potentially contribute to safer and more effective systems of care. We utilized in-situ simulation to highlight safety issues, regulatory requirements, and assess perceptions of safety processes by the plastic surgery office staff. A high-fidelity human patient simulator was brought to an office-based plastic surgery setting to enact a half-day full-scale, multidisciplinary medical emergency. Facilitated group debriefings were conducted after each scenario with special consideration of the principles of team training, communication, crisis management, and adherence to evidence-based protocols and regulatory standards. Abbreviated AHRQ Medical Office Safety Culture Survey was completed by the participants before and after the session. The in-situ simulations had a high degree of acceptance and face validity according to the participants. Areas highlighted by the simulation sessions included rapid communication, delegation of tasks, location of emergency materials, scope of practice, and logistics of transport. The participant survey indicated greater awareness of patient safety issues following participation in simulation and debriefing exercises in 3 areas (P issue (100% vs 75%), openness to ideas about improving office processes (100% vs 88%), and the need to discuss ways to prevent errors from recurring (88% vs 62%). Issues of safety and regulatory compliance can be assessed in an office-based setting through the short-term (half-day) use of in-situ simulation with facilitated debriefing and the review of audiovisual recordings by trained facilities inspectors.

  18. Virtual surgery simulation versus traditional approaches in training of residents in cervical pedicle screw placement.

    Science.gov (United States)

    Hou, Yang; Shi, Jiangang; Lin, Yanping; Chen, Huajiang; Yuan, Wen

    2018-06-01

    The cervical screw placement is one of the most difficult procedures in spine surgery, which often needs a long period of repeated practices and could cause screw placement-related complications. We performed this cadaver study to investigate the effectiveness of virtual surgical training system (VSTS) on cervical pedicle screw instrumentation for residents. A total of ten novice residents were randomly assigned to two groups: the simulation training (ST) group (n = 5) and control group (n = 5). The ST group received a surgical training of cervical pedicle screw placement on VSTS and the control group was given an introductory teaching session before cadaver test. Ten fresh adult spine specimens including 6 males and 4 females were collected, and were randomly allocated to the two groups. The bilateral C3-C6 pedicle screw instrumentation was performed in the specimens of the two groups, respectively. After instrumentation, screw positions of the two groups were evaluated by image examinations. There was significantly statistical difference in screw penetration rates between the ST (10%) and control group (62.5%, P VSTS as an advanced training tool exhibited promising effects on improving performance of novice residents in cervical pedicle screw placement compared with the traditional teaching methods.

  19. Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing.

    Science.gov (United States)

    Oshiro, Yukio; Ohkohchi, Nobuhiro

    2017-06-01

    To perform accurate hepatectomy without injury, it is necessary to understand the anatomical relationship among the branches of Glisson's sheath, hepatic veins, and tumor. In Japan, three-dimensional (3D) preoperative simulation for liver surgery is becoming increasingly common, and liver 3D modeling and 3D hepatectomy simulation by 3D analysis software for liver surgery have been covered by universal healthcare insurance since 2012. Herein, we review the history of virtual hepatectomy using computer-assisted surgery (CAS) and our research to date, and we discuss the future prospects of CAS. We have used the SYNAPSE VINCENT medical imaging system (Fujifilm Medical, Tokyo, Japan) for 3D visualization and virtual resection of the liver since 2010. We developed a novel fusion imaging technique combining 3D computed tomography (CT) with magnetic resonance imaging (MRI). The fusion image enables us to easily visualize anatomic relationships among the hepatic arteries, portal veins, bile duct, and tumor in the hepatic hilum. In 2013, we developed an original software, called Liversim, which enables real-time deformation of the liver using physical simulation, and a randomized control trial has recently been conducted to evaluate the use of Liversim and SYNAPSE VINCENT for preoperative simulation and planning. Furthermore, we developed a novel hollow 3D-printed liver model whose surface is covered with frames. This model is useful for safe liver resection, has better visibility, and the production cost is reduced to one-third of a previous model. Preoperative simulation and navigation with CAS in liver resection are expected to help planning and conducting a surgery and surgical education. Thus, a novel CAS system will contribute to not only the performance of reliable hepatectomy but also to surgical education.

  20. Video-based peer feedback through social networking for robotic surgery simulation: a multicenter randomized controlled trial.

    Science.gov (United States)

    Carter, Stacey C; Chiang, Alexander; Shah, Galaxy; Kwan, Lorna; Montgomery, Jeffrey S; Karam, Amer; Tarnay, Christopher; Guru, Khurshid A; Hu, Jim C

    2015-05-01

    To examine the feasibility and outcomes of video-based peer feedback through social networking to facilitate robotic surgical skill acquisition. The acquisition of surgical skills may be challenging for novel techniques and/or those with prolonged learning curves. Randomized controlled trial involving 41 resident physicians performing the Tubes (Da Vinci Intuitive Surgical, Sunnyvale, CA) simulator exercise with versus without peer feedback of video-recorded performance through a social networking Web page. Data collected included simulator exercise score, time to completion, and comfort and satisfaction with robotic surgery simulation. There were no baseline differences between the intervention group (n = 20) and controls (n = 21). The intervention group showed improvement in mean scores from session 1 to sessions 2 and 3 (60.7 vs 75.5, P feedback subjects were more comfortable with robotic surgery than controls (90% vs 62%, P = 0.021) and expressed greater satisfaction with the learning experience (100% vs 67%, P = 0.014). Of the intervention subjects, 85% found that peer feedback was useful and 100% found it effective. Video-based peer feedback through social networking appears to be an effective paradigm for surgical education and accelerates the robotic surgery learning curve during simulation.

  1. Protocol for concomitant temporomandibular joint custom-fitted total joint reconstruction and orthognathic surgery utilizing computer-assisted surgical simulation.

    Science.gov (United States)

    Movahed, Reza; Teschke, Marcus; Wolford, Larry M

    2013-12-01

    Clinicians who address temporomandibular joint (TMJ) pathology and dentofacial deformities surgically can perform the surgery in 1 stage or 2 separate stages. The 2-stage approach requires the patient to undergo 2 separate operations and anesthesia, significantly prolonging the overall treatment. However, performing concomitant TMJ and orthognathic surgery (CTOS) in these cases requires careful treatment planning and surgical proficiency in the 2 surgical areas. This article presents a new treatment protocol for the application of computer-assisted surgical simulation in CTOS cases requiring reconstruction with patient-fitted total joint prostheses. The traditional and new CTOS protocols are described and compared. The new CTOS protocol helps decrease the preoperative workup time and increase the accuracy of model surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Ear-to-Ear On-Body Channel Model for Hearing Aid Applications

    DEFF Research Database (Denmark)

    Kvist, Søren Helstrup; Thaysen, Jesper; Jakobsen, Kaj Bjarne

    2015-01-01

    that the head is mod- eled more accurately, and the radiation pattern is sampled in more points. The model is able to take the on-body radiation pattern of the antenna, as well as arbitrary he ad contours into account. The model is validated by the use of measurements and Ansys HFSS simulations on the specific......The deterministic ear-to-ear on-body channel is modeled by the use of a number of elliptically shaped paths. The semi-major axes of the elliptica lly shaped paths are adjusted such that they trace the outline of the head. The path gain converges when the number of paths is increased, su ch...... anthropomorphic mannequin (SAM) head. The model is used with a g enetic algorithm in order to synthesize a radiation pattern that is optimal for use with the ear-to-ear on-body channel. The radiation pattern is synthesized in terms of the spherical wave expansion coefficients of the hypothetical small antenna...

  3. Human ear recognition by computer

    CERN Document Server

    Bhanu, Bir; Chen, Hui

    2010-01-01

    Biometrics deals with recognition of individuals based on their physiological or behavioral characteristics. The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. Unlike the fingerprint and iris, it can be easily captured from a distance without a fully cooperative subject, although sometimes it may be hidden with hair, scarf and jewellery. Also, unlike a face, the ear is a relatively stable structure that does not change much with the age and facial expressions. ""Human Ear Recognition by Computer"" is the first book o

  4. Patient-specific surgical simulator for the pre-operative planning of single-incision laparoscopic surgery with bimanual robots.

    Science.gov (United States)

    Turini, Giuseppe; Moglia, Andrea; Ferrari, Vincenzo; Ferrari, Mauro; Mosca, Franco

    2012-01-01

    The trend of surgical robotics is to follow the evolution of laparoscopy, which is now moving towards single-incision laparoscopic surgery. The main drawback of this approach is the limited maneuverability of the surgical tools. Promising solutions to improve the surgeon's dexterity are based on bimanual robots. However, since both robot arms are completely inserted into the patient's body, issues related to possible unwanted collisions with structures adjacent to the target organ may arise. This paper presents a simulator based on patient-specific data for the positioning and workspace evaluation of bimanual surgical robots in the pre-operative planning of single-incision laparoscopic surgery. The simulator, designed for the pre-operative planning of robotic laparoscopic interventions, was tested by five expert surgeons who evaluated its main functionalities and provided an overall rating for the system. The proposed system demonstrated good performance and usability, and was designed to integrate both present and future bimanual surgical robots.

  5. Handheld Micromanipulator for Robot-Assisted Stapes Footplate Surgery

    Science.gov (United States)

    Grande, Gonzalo Montes; Knisely, Anna J.; Becker, Brian C.; Yang, Sungwook; Hirsch, Barry E.; Riviere, Cameron N.

    2012-01-01

    Stapes footplate surgery is complex and delicate. This surgery is carried out in the middle ear to improve hearing. High accuracy is required to avoid critical tissues and structures near the surgical worksite. By suppressing the surgeon’s tremor during the operation, accuracy can be improved. In this paper, a fully handheld active micromanipulator known as Micron is evaluated for its feasibility for this delicate operation. An ergonomic handle, a custom tip, and a brace attachment were designed for stapes footplate surgery and tested in a fenestration task through a fixed speculum. Accuracy was measured during simulated surgery in two different scenarios: Micron off (unaided) and Micron on (aided), both with image guidance. Preliminary results show that Micron significantly reduces the mean position error and the mean duration of time spent in specified dangerous zones. PMID:23366167

  6. How the Ear Works

    Science.gov (United States)

    ... to the brain via the hearing nerve. The brain interprets the impulses as sound (music, voice, a car horn, etc.). View Video Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly prohibited without prior written permission. ...

  7. Tail Docking and Ear Cropping Dogs: Public Awareness and Perceptions.

    Directory of Open Access Journals (Sweden)

    Katelyn E Mills

    Full Text Available Tail docking and ear cropping are two surgical procedures commonly performed on many dog breeds. These procedures are classified as medically unnecessary surgeries whose purpose is primarily cosmetic. Available attitude research surrounding these controversial practices has been limited to surveys of veterinarians and dog breeders familiar with both practices. The aim of this project was to: 1 assess public awareness of tail docking and ear cropping, 2 determine whether physical alteration of a dog affects how the dog, and 3 owner are perceived. In Experiment 1 awareness was measured using a combination of both explicit and implicit measures. We found that 42% of participants (n = 810 were unable to correctly explain the reason why tail docked and ear cropped dogs had short ears and tails. Similarly, an implicit measure of awareness ('nature vs nurture task', found that the majority of participants believed short tails and erect ears were a consequence of genetics rather than something the owner or breeder had done. The results obtained in Experiment 2 (n = 392 provide evidence that ear cropped and tail docked dogs are perceived differently than an identical dog in its 'natural' state. Modified dogs were perceived as being more aggressive, more dominant, less playful and less attractive than natural dogs. Experiment 3 (n = 410 is the first evidence that owners of modified dogs are perceived as being more aggressive, more narcissistic, less playful, less talkative and less warm compared to owners of natural dogs. Taken together, these results suggest that although a significant proportion of subjects appear unaware of the practices of tail docking and ear cropping in dogs, these procedures have significant impacts on how modified dogs and their owners are perceived by others.

  8. Tail Docking and Ear Cropping Dogs: Public Awareness and Perceptions.

    Science.gov (United States)

    Mills, Katelyn E; Robbins, Jesse; von Keyserlingk, Marina A G

    2016-01-01

    Tail docking and ear cropping are two surgical procedures commonly performed on many dog breeds. These procedures are classified as medically unnecessary surgeries whose purpose is primarily cosmetic. Available attitude research surrounding these controversial practices has been limited to surveys of veterinarians and dog breeders familiar with both practices. The aim of this project was to: 1) assess public awareness of tail docking and ear cropping, 2) determine whether physical alteration of a dog affects how the dog, and 3) owner are perceived. In Experiment 1 awareness was measured using a combination of both explicit and implicit measures. We found that 42% of participants (n = 810) were unable to correctly explain the reason why tail docked and ear cropped dogs had short ears and tails. Similarly, an implicit measure of awareness ('nature vs nurture task'), found that the majority of participants believed short tails and erect ears were a consequence of genetics rather than something the owner or breeder had done. The results obtained in Experiment 2 (n = 392) provide evidence that ear cropped and tail docked dogs are perceived differently than an identical dog in its 'natural' state. Modified dogs were perceived as being more aggressive, more dominant, less playful and less attractive than natural dogs. Experiment 3 (n = 410) is the first evidence that owners of modified dogs are perceived as being more aggressive, more narcissistic, less playful, less talkative and less warm compared to owners of natural dogs. Taken together, these results suggest that although a significant proportion of subjects appear unaware of the practices of tail docking and ear cropping in dogs, these procedures have significant impacts on how modified dogs and their owners are perceived by others.

  9. Global Ear. Werke 2001 - 2006

    Index Scriptorium Estoniae

    2006-01-01

    Dresdenis muusikafestivalil "Global Ear" 23.3.03 esitusel Eesti heliloojate muusika: Helena Tulve "lumineux/opaque", Jaan Rääts "Meditation", Mirjam Tally "Aura", Mati Kuulberg "Sonate Nr.4", Mari Vihmand "Seitsmele"

  10. COMMON INFECTIONS OF THE EAR

    African Journals Online (AJOL)

    Enrique

    tion of the skin covering the tympanic membrane and deep exter- nal canal, and the production of ... of combination steroid/antifungal/antibiotic ointment (e.g.. Kenacomb) with a cotton bud ..... protection to the delicate middle ear structures.

  11. Barriers to the implementation and uptake of simulation-based training programs in general surgery: a multinational qualitative study.

    Science.gov (United States)

    Hosny, Shady G; Johnston, Maximilian J; Pucher, Philip H; Erridge, Simon; Darzi, Ara

    2017-12-01

    Despite evidence demonstrating the advantages of simulation training in general surgery, it is not widely integrated into surgical training programs worldwide. The aim of this study was to identify barriers and facilitators to the implementation and uptake of surgical simulation training programs. A multinational qualitative study was conducted using semi-structured interviews of general surgical residents and experts. Each interview was audio recorded, transcribed verbatim, and underwent emergent theme analysis. All data were anonymized and results pooled. A total of 37 individuals participated in the study. Seventeen experts (Program Directors and Surgical Attendings with an interest in surgical education) and 20 residents drawn from the United States, Canada, United Kingdom, France, and Japan were interviewed. Barriers to simulation-based training were identified based on key themes including financial cost, access, and translational benefit. Participants described cost (89%) and access (76%) as principal barriers to uptake. Common facilitators included a mandatory requirement to complete simulation training (78%) and on-going assessment of skills (78%). Participants felt that simulation training could improve patient outcomes (76%) but identified a lack of evidence to demonstrate benefit (38%). There was a consensus that simulation training has not been widely implemented (70%). There are multiple barriers to the implementation of surgical simulation training programs, however, there is agreement that these programs could potentially improve patient outcomes. Identifying these barriers enable the targeted use of facilitators to deliver simulation training programs. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Enhanced visualization of inner ear structures

    Science.gov (United States)

    Niemczyk, Kazimierz; Kucharski, Tomasz; Kujawinska, Malgorzata; Bruzgielewicz, Antoni

    2004-07-01

    Recently surgery requires extensive support from imaging technologies in order to increase effectiveness and safety of operations. One of important tasks is to enhance visualisation of quasi-phase (transparent) 3d structures. Those structures are characterized by very low contrast. It makes differentiation of tissues in field of view very difficult. For that reason the surgeon may be extremly uncertain during operation. This problem is connected with supporting operations of inner ear during which physician has to perform cuts at specific places of quasi-transparent velums. Conventionally during such operations medical doctor views the operating field through stereoscopic microscope. In the paper we propose a 3D visualisation system based on Helmet Mounted Display. Two CCD cameras placed at the output of microscope perform acquisition of stereo pairs of images. The images are processed in real-time with the goal of enhancement of quasi-phased structures. The main task is to create algorithm that is not sensitive to changes in intensity distribution. The disadvantages of existing algorithms is their lack of adaptation to occuring reflexes and shadows in field of view. The processed images from both left and right channels are overlaid on the actual images exported and displayed at LCD's of Helmet Mounted Display. A physician observes by HMD (Helmet Mounted Display) a stereoscopic operating scene with indication of the places of special interest. The authors present the hardware ,procedures applied and initial results of inner ear structure visualisation. Several problems connected with processing of stereo-pair images are discussed.

  13. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery

    Directory of Open Access Journals (Sweden)

    Hideyuki Suenaga

    2016-01-01

    Conclusion: The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results.

  14. Lobule separator prosthesis to prevent adhesion of reconstructed ear lobe

    Directory of Open Access Journals (Sweden)

    Lokendra Gupta

    2016-01-01

    Full Text Available An adhesion is a band of scar tissue that binds two parts of the tissue together, which develops when the body's repair mechanisms respond to any tissue disturbance, such as surgery, infection, trauma, or radiation. Prevention of unwanted scar bands is of utmost importance to develop esthetic and healthy tissue. This article describes a technique to prevent the adhesion of the surgically reconstructed ear lobule with facial skin, using novel lobule separator prosthesis.

  15. A new possibility in thoracoscopic virtual reality simulation training: development and testing of a novel virtual reality simulator for video-assisted thoracoscopic surgery lobectomy.

    Science.gov (United States)

    Jensen, Katrine; Bjerrum, Flemming; Hansen, Henrik Jessen; Petersen, René Horsleben; Pedersen, Jesper Holst; Konge, Lars

    2015-10-01

    The aims of this study were to develop virtual reality simulation software for video-assisted thoracic surgery (VATS) lobectomy, to explore the opinions of thoracic surgeons concerning the VATS lobectomy simulator and to test the validity of the simulator metrics. Experienced VATS surgeons worked with computer specialists to develop a VATS lobectomy software for a virtual reality simulator. Thoracic surgeons with different degrees of experience in VATS were enrolled at the 22nd meeting of the European Society of Thoracic Surgeons (ESTS) held in Copenhagen in June 2014. The surgeons were divided according to the number of performed VATS lobectomies: novices (0 VATS lobectomies), intermediates (1-49 VATS lobectomies) and experienced (>50 VATS lobectomies). The participants all performed a lobectomy of a right upper lobe on the simulator and answered a questionnaire regarding content validity. Metrics were compared between the three groups. We succeeded in developing the first version of a virtual reality VATS lobectomy simulator. A total of 103 thoracic surgeons completed the simulated lobectomy and were distributed as follows: novices n = 32, intermediates n = 45 and experienced n = 26. All groups rated the overall user realism of the VATS lobectomy scenario to a median of 5 on a scale 1-7, with 7 being the best score. The experienced surgeons found the graphics and movements realistic and rated the scenario high in terms of usefulness as a training tool for novice and intermediate experienced thoracic surgeons, but not very useful as a training tool for experienced surgeons. The metric scores were not statistically significant between groups. This is the first study to describe a commercially available virtual reality simulator for a VATS lobectomy. More than 100 thoracic surgeons found the simulator realistic, and hence it showed good content validity. However, none of the built-in simulator metrics could significantly distinguish between novice, intermediate

  16. 3D Printed Bionic Ears

    Science.gov (United States)

    Mannoor, Manu S.; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A.; Soboyejo, Winston O.; Verma, Naveen; Gracias, David H.; McAlpine, Michael C.

    2013-01-01

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the precise anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing. PMID:23635097

  17. 3D printed bionic ears.

    Science.gov (United States)

    Mannoor, Manu S; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A; Soboyejo, Winston O; Verma, Naveen; Gracias, David H; McAlpine, Michael C

    2013-06-12

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing.

  18. Ear Disorders in Scuba Divers

    Directory of Open Access Journals (Sweden)

    MH Azizi

    2010-12-01

    Full Text Available History of underwater diving dates back to antiquity. Breath-hold technique in diving was known to the ancient nations. However, deep diving progressed only in the early decades of the 19th century as the result of advancements in efficient underwater technologies which subsequently led to invention of sophisticated sets of scuba diving in the 20th century. Currently, diving is performed for various purposes including commercial, recreational, military, underwater construction, oil industry, underwater archeology and scientific assessment of marine life. By increasing popularity of underwater diving, dive-related medical conditions gradually became more evident and created a new challenge for the health care professionals, so that eventually, a specialty the so-called “diving medicine” was established. Most of the diving-associated disorders appear in the head and neck. The most common of all occupational disorders associated with diving are otologic diseases. External otitis has been reported as the most common otolaryngologic problem in underwater divers. Exostosis of the external ear canal may be formed in divers as the result of prolonged diving in cold waters. Other disorders of the ear and paranasal sinuses in underwater divers are caused by barometric pressure change (i.e., barotraumas, and to a lesser extent by decompression sickness. Barotrauma of the middle ear is the most prevalent barotrauma in divers. The inner ear barotraumas, though important, is less common. The present paper is a brief overview of diving-related ear disorders particularly in scuba divers.

  19. Clinical analysis of ear carcinoma treated in the Department of Otolaryngology, Niigata University Hospital. Focus on correlation between treatment method and prognosis

    International Nuclear Information System (INIS)

    Sato, Katsuro; Tomita, Masahiko; Takahashi, Sugata; Watanabe, Jun; Matsuyama, Hiroshi

    2008-01-01

    Thirty-six patients of ear carcinoma treated in our department were clinically analyzed. Those ear carcinoma patients accounted for 3.5% of all head and neck carcinoma patients. The most common primary site was the external auditory canal (67%), followed by the middle ear (19%) and the auricle (14%). The mean age of the patients was 66 years old, and the male to female ratio was 3:2. The most common chief complaint of the external auditory canal and middle ear carcinoma was otorrhea followed by ear itching and ear ache. Of patients with external auditory canal carcinoma and middle ear carcinoma, 26% had a history of ear surgery, and 35% had a habit of ear-picking. Histopathologically, 94% of the patients were squamous cell carcinoma, and 6% were malignant melanoma. Sixty-two % of squamous cell carcinoma patients underwent surgery, and the remaining 38% had radiotherapy without surgery. Postoperative radiotherapy was added for 67% of the surgery group. Five-year survival rates of the patients with squamous cell carcinoma were 74% for external auditory canal carcinoma, 67% for auricular carcinoma, and 34% for middle ear carcinoma, respectively. The five-year survival rate of the surgery group was 82%, and that of the non-surgery group was 29%. There was a statistical significance between the two groups. No statistical significance was seen between with and without postoperative radiotherapy. In the treatment of squamous cell carcinoma in the ear, radical en bloc surgery followed by postoperative radiotherapy was considered to be an appropriate treatment strategy. (author)

  20. [SOX10 mutation is relevant to inner ear malformation in patients with Waardenburg syndrome].

    Science.gov (United States)

    Xu, G Y; Hao, Q Q; Zhong, L L; Ren, W; Yan, Y; Liu, R Y; Li, J N; Guo, W W; Zhao, H; Yang, S M

    2016-11-07

    Objective: To determine the relevance between the SOX 10 mutation and Waardenburg syndrome (WS) accompanied with inner ear abnormality by analyzing the inner ear imaging results and molecular and genetic results of the WS patients with the SOX 10 mutation. Methods: This study included 36 WS in patients during 2001 and 2015 in the department of otorhinolaryngology head and neck surgery, Chinese Peoples's Liberation Army General Hospital. The condition of the inner ear of each patient was assessed by analyzing HRCT scans of the temporal bone and MRI scans of the brain and internal auditory canal. Meanwhile, the possible pathogenic genes of WS, including SOX10, MITF , and PAX 3, were also screened. Patients were divided into two groups according to SOX 10 mutation.The Fisher accuracy test was used to determine statistical difference of inner ear deformation incidence between the two groups. Results: Among all 36 patients, 12 were found to have inner ear abnormality. Most abnormalities were posterior semicircular canal deformations, some accompanied with cochlear deformation and an enlarged vestibule. Among all patients, 9 patients were SOX 10 heterozygous mutation carriers, among which six showed bilateral inner ear abnormality. Fisher accuracy test results suggested a significant correlation between the SOX 10 mutation and inner ear abnormality in WS patients ( P =0.036). Conclusion: This study found that WS patients with the SOX 10 mutation are more likely to have deformed inner ears when compared to WS patients without the SOX 10 mutation.

  1. Freeform fabrication of tissue-simulating phantom for potential use of surgical planning in conjoined twins separation surgery.

    Science.gov (United States)

    Shen, Shuwei; Wang, Haili; Xue, Yue; Yuan, Li; Zhou, Ximing; Zhao, Zuhua; Dong, Erbao; Liu, Bin; Liu, Wendong; Cromeens, Barrett; Adler, Brent; Besner, Gail; Xu, Ronald X

    2017-09-08

    Preoperative assessment of tissue anatomy and accurate surgical planning is crucial in conjoined twin separation surgery. We developed a new method that combines three-dimensional (3D) printing, assembling, and casting to produce anatomic models of high fidelity for surgical planning. The related anatomic features of the conjoined twins were captured by computed tomography (CT), classified as five organ groups, and reconstructed as five computer models. Among these organ groups, the skeleton was produced by fused deposition modeling (FDM) using acrylonitrile-butadiene-styrene. For the other four organ groups, shell molds were prepared by FDM and cast with silica gel to simulate soft tissues, with contrast enhancement pigments added to simulate different CT and visual contrasts. The produced models were assembled, positioned firmly within a 3D printed shell mold simulating the skin boundary, and cast with transparent silica gel. The produced phantom was subject to further CT scan in comparison with that of the patient data for fidelity evaluation. Further data analysis showed that the produced model reassembled the geometric features of the original CT data with an overall mean deviation of less than 2 mm, indicating the clinical potential to use this method for surgical planning in conjoined twin separation surgery.

  2. Multiaxial mechanical properties and constitutive modeling of human adipose tissue: a basis for preoperative simulations in plastic and reconstructive surgery.

    Science.gov (United States)

    Sommer, Gerhard; Eder, Maximilian; Kovacs, Laszlo; Pathak, Heramb; Bonitz, Lars; Mueller, Christoph; Regitnig, Peter; Holzapfel, Gerhard A

    2013-11-01

    A preoperative simulation of soft tissue deformations during plastic and reconstructive surgery is desirable to support the surgeon's planning and to improve surgical outcomes. The current development of constitutive adipose tissue models, for the implementation in multilayer computational frameworks for the simulation of human soft tissue deformations, has proved difficult because knowledge of the required mechanical parameters of fat tissue is limited. Therefore, for the first time, human abdominal adipose tissues were mechanically investigated by biaxial tensile and triaxial shear tests. The results of this study suggest that human abdominal adipose tissues under quasi-static and dynamic multiaxial loadings can be characterized as a nonlinear, anisotropic and viscoelastic soft biological material. The nonlinear and anisotropic features are consequences of the material's collagenous microstructure. The aligned collagenous septa observed in histological investigations causes the anisotropy of the tissue. A hyperelastic model used in this study was appropriate to represent the quasi-static multiaxial mechanical behavior of fat tissue. The constitutive parameters are intended to serve as a basis for soft tissue simulations using the finite element method, which is an apparent method for obtaining promising results in the field of plastic and reconstructive surgery. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. Innovations in surgery simulation: a review of past, current and future techniques

    OpenAIRE

    Badash, Ido; Burtt, Karen; Solorzano, Carlos A.; Carey, Joseph N.

    2016-01-01

    As a result of recent work-hours limitations and concerns for patient safety, innovations in extraclinical surgical simulation have become a desired part of residency education. Current simulation models, including cadaveric, animal, bench-top, virtual reality (VR) and robotic simulators are increasingly used in surgical training programs. Advances in telesurgery, three-dimensional (3D) printing, and the incorporation of patient-specific anatomy are paving the way for simulators to become int...

  4. Realistic prediction of individual facial emotion expressions for craniofacial surgery simulations

    Science.gov (United States)

    Gladilin, Evgeny; Zachow, Stefan; Deuflhard, Peter; Hege, Hans-Christian

    2003-05-01

    In addition to the static soft tissue prediction, the estimation of individual facial emotion expressions is an important criterion for the evaluation of the carniofacial surgery planning. In this paper, we present an approach for the estimation of individual facial emotion expressions on the basis of geometrical models of human anatomy derived from tomographic data and the finite element modeling of facial tissue biomechanics.

  5. Assessing Technical Performance and Determining the Learning Curve in Cleft Palate Surgery Using a High-Fidelity Cleft Palate Simulator.

    Science.gov (United States)

    Podolsky, Dale J; Fisher, David M; Wong Riff, Karen W; Szasz, Peter; Looi, Thomas; Drake, James M; Forrest, Christopher R

    2018-06-01

    This study assessed technical performance in cleft palate repair using a newly developed assessment tool and high-fidelity cleft palate simulator through a longitudinal simulation training exercise. Three residents performed five and one resident performed nine consecutive endoscopically recorded cleft palate repairs using a cleft palate simulator. Two fellows in pediatric plastic surgery and two expert cleft surgeons also performed recorded simulated repairs. The Cleft Palate Objective Structured Assessment of Technical Skill (CLOSATS) and end-product scales were developed to assess performance. Two blinded cleft surgeons assessed the recordings and the final repairs using the CLOSATS, end-product scale, and a previously developed global rating scale. The average procedure-specific (CLOSATS), global rating, and end-product scores increased logarithmically after each successive simulation session for the residents. Reliability of the CLOSATS (average item intraclass correlation coefficient (ICC), 0.85 ± 0.093) and global ratings (average item ICC, 0.91 ± 0.02) among the raters was high. Reliability of the end-product assessments was lower (average item ICC, 0.66 ± 0.15). Standard setting linear regression using an overall cutoff score of 7 of 10 corresponded to a pass score for the CLOSATS and the global score of 44 (maximum, 60) and 23 (maximum, 30), respectively. Using logarithmic best-fit curves, 6.3 simulation sessions are required to reach the minimum standard. A high-fidelity cleft palate simulator has been developed that improves technical performance in cleft palate repair. The simulator and technical assessment scores can be used to determine performance before operating on patients.

  6. Evaluation of a Pilot Project to Introduce Simulation-Based Team Training to Pediatric Surgery Trauma Room Care

    Directory of Open Access Journals (Sweden)

    Markus Lehner

    2017-01-01

    Full Text Available Introduction. Several studies in pediatric trauma care have demonstrated substantial deficits in both prehospital and emergency department management. Methods. In February 2015 the PAEDSIM collaborative conducted a one and a half day interdisciplinary, simulation based team-training course in a simulated pediatric emergency department. 14 physicians from the medical fields of pediatric surgery, pediatric intensive care and emergency medicine, and anesthesia participated, as well as four pediatric nurses. After a theoretical introduction and familiarization with the simulator, course attendees alternately participated in six simulation scenarios and debriefings. Each scenario incorporated elements of pediatric trauma management as well as Crew Resource Management (CRM educational objectives. Participants completed anonymous pre- and postcourse questionnaires and rated the course itself as well as their own medical qualification and knowledge of CRM. Results. Participants found the course very realistic and selected scenarios highly relevant to their daily work. They reported a feeling of improved medical and nontechnical skills as well as no uncomfortable feeling during scenarios or debriefings. Conclusion. To our knowledge this pilot-project represents the first successful implementation of a simulation-based team-training course focused on pediatric trauma care in German-speaking countries with good acceptance.

  7. Digital Active Noise Reduction Ear Plugs

    National Research Council Canada - National Science Library

    Harley, Thomas

    1994-01-01

    .... In contrast to available ANR headsets that implement fixed analog filters, the prototype defines a digital filter that is optimally defined for the user's current acoustical environment. An above-the-ear (ATE) and an in-the-ear (ITE...

  8. Middle ear infection (otitis media) (image)

    Science.gov (United States)

    Otitis media is an inflammation or infection of the middle ear. Acute otitis media (acute ear infection) occurs when there is ... which causes production of fluid or pus. Chronic otitis media occurs when the eustachian tube becomes blocked ...

  9. External ear: An analysis of its uniqueness

    Directory of Open Access Journals (Sweden)

    Ruma Purkait

    2016-06-01

    Hence, the individuality of every ear has been confirmed which may find use in personal identification studies. The study is a step towards providing scientific support for admitting ear evidence in the Court of Law.

  10. Proteomics and the Inner Ear

    Directory of Open Access Journals (Sweden)

    Isolde Thalmann

    2001-01-01

    Full Text Available The inner ear, one of the most complex organs, contains within its bony shell three sensory systems, the evolutionary oldest gravity receptor system, the three semicircular canals for the detection of angular acceleration, and the auditory system - unrivaled in sensitivity and frequency discrimination. All three systems are susceptible to a host of afflictions affecting the quality of life for all of us. In the first part of this review we present an introduction to the milestones of inner ear research to pave the way for understanding the complexities of a proteomics approach to the ear. Minute sensory structures, surrounded by large fluid spaces and a hard bony shell, pose extreme challenges to the ear researcher. In spite of these obstacles, a powerful preparatory technique was developed, whereby precisely defined microscopic tissue elements can be isolated and analyzed, while maintaining the biochemical state representative of the in vivo conditions. The second part consists of a discussion of proteomics as a tool in the elucidation of basic and pathologic mechanisms, diagnosis of disease, as well as treatment. Examples are the organ of Corti proteins OCP1 and OCP2, oncomodulin, a highly specific calcium-binding protein, and several disease entities, Meniere's disease, benign paroxysmal positional vertigo, and perilymphatic fistula.

  11. Psychomotor skills and cognitive load training on a virtual reality laparoscopic simulator for tubal surgery is effective.

    Science.gov (United States)

    Bharathan, Rasiah; Vali, Saaliha; Setchell, Thomas; Miskry, Tariq; Darzi, Ara; Aggarwal, Rajesh

    2013-07-01

    Validation of a virtual reality (VR) simulator for the training and assessment of laparoscopic tubal surgery and mapping of cognitive load. Prospective cohort study conducted at the Imperial College Virtual Reality Surgical Skills laboratory amongst 25 trainees and nine senior gynaecologists. Participants performed two sessions of salpingectomy and salpingotomy procedures on a VR simulator to assess construct validity. Nine novices performed ten such sessions to enable assessment of the learning curve. The relationship between cognitive load and the dexterity parameters was assessed. Simulator fidelity was reported by experienced and intermediate level gynaecologists. Statistical analyses utilised non-parametric tests, Kruskall-Wallis and Mann-Whitney U tests. Learning curves were assessed using the Friedman test and Wilcoxon Signed Ranks test. Relationship between dexterity metrics and cognitive load was performed using Spearman's rank order correlation. Salpingectomy demonstrated construct validity for time taken by experienced, intermediate and novice gynaecologists (median 170 vs. 191 vs. 313s (P=0.003) respectively) and movements (median 200 vs. 267 vs. 376s, P=0.045). Salpingotomy demonstrated construct validity for time taken (median 183 vs. 191 vs. 306s, P=<0.001) and movements (median 210 vs. 233 vs. 328s, P=0.005). Learning curve analysis for salpingectomy displayed a plateau for time taken after the eighth session, and the fourth session for movements. Salpingotomy displayed a plateau after the eighth session for both time taken and movements. Cognitive load correlated significantly with dexterity parameters. The fidelity scores were not significantly different between the two procedures (P=0.619). The LAP Mentor VR laparoscopic simulator is a valid and effective tool for training novice surgeons in ectopic pregnancy surgery. Reduction in cognitive load significantly correlates with the learning curves. Copyright © 2013 Elsevier Ireland Ltd. All rights

  12. The Effectiveness of Public Simulated Oral Examinations in Preparation for the American Board of Surgery Certifying Examination: A Systematic Review.

    Science.gov (United States)

    Pennell, Christopher; McCulloch, Peter

    2015-01-01

    The purpose of this study was to determine whether American Board of Surgery Certifying Examination (CE) performance is improved among residents who prepare using simulated oral examinations (SOEs). EMBASE and MEDLINE were searched using predefined search terms. No language restrictions were imposed and the latest search date was in November 2014. Included studies must have reported on residents training in a general surgery residency in the United States who used SOEs to prepare for the CE and have measured their performance against those without exposure to SOEs. Studies meeting inclusion criteria were qualitatively and quantitatively analyzed and a fixed effects meta-analysis was performed to determine the net effect of SOEs on CE performance. Overall, 4 of 25 abstracts reviewed met inclusion criteria and are included in this review. The most common simulation format included public examinations in front of resident peers during scheduled education sessions. All 4 included studies trended toward improved performance with SOEs and in 2 of these studies the improvement was statistically significant. Overall, 3 studies were of adequate quality to perform a meta-analysis and demonstrated a relative risk for first-attempt CE success of 1.22 (95% CI: 1.07-1.39, p = 0.003) for residents preparing with SOEs compared to those without SOEs. The published literature evaluating SOEs is limited and generally of fair quality. A modest improvement in CE performance was identified when public SOEs were used as an educational tool aimed to improve professionalism and communication skills, encourage reading at home, and provide a regular review of clinically relevant topics. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. Can Loud Music Hurt My Ears?

    Science.gov (United States)

    ... Videos for Educators Search English Español Can Loud Music Hurt My Ears? KidsHealth / For Kids / Can Loud Music Hurt My Ears? Print en español La música ... up? Oh! You want to know if loud music can hurt your ears . Are you asking because ...

  14. Face and construct validity of virtual reality simulation of laparoscopic gynecologic surgery

    NARCIS (Netherlands)

    Schreuder, Henk W. R.; van Dongen, Koen W.; Roeleveld, Susan J.; Schijven, Marlies P.; Broeders, Ivo A. M. J.

    2009-01-01

    OBJECTIVE: The objective of the study was to validate virtual reality simulation in assessing laparoscopic skills in gynecology by establishing the extent of realism of the simulation to the actual task (face validity) and the degree to which the results of the test one uses reflects the subject

  15. Carcinoma of the middle ear and external auditory canal

    International Nuclear Information System (INIS)

    Hahn, S.S.; Kim, J.A.; Goodchild, N.; Constable, W.C.

    1983-01-01

    Thirty-one patients with malignant tumors of the middle ear and external auditory canal (EAC) were observed at the University of Virginia Hospital from 1956 through 1980. Of 27 patients with carcinoma, 21 had squamous cell carcinoma, 4 had basal cell carcinoma and 2 had adenoid cystic carcinoma. The 27 patients with carcinoma are reviewed with regard to clinical presentation, treatment modality, results and complications. The majority (67%) of patients had a history of chronic ear drainage, 22% had a previous mastoidectomy or polypectomy and 7% had an associated cholesteatoma. Eighty percent of patients with carcinoma limited to EAC were alive and well at 5 years, compared to 43% of patients with involvement of the middle ear. Fifty-six percent of patients without invasion of the petrous bone were alive at 5 years compared to only 20% of patients with petrous bone involvement. The data strongly suggest that survival depends on the extent of disease. The corrected disease free 5 year survival rates were 14% for patients who had surgery alone and 50% for those who had surgery and radiotherapy. Of the three patients with advanced disease who received radiotherapy alone, none survived five years

  16. Classification and Current Management of Inner Ear Malformations

    Directory of Open Access Journals (Sweden)

    Levent Sennaroğlu

    2017-10-01

    Full Text Available Morphologically congenital sensorineural hearing loss can be investigated under two categories. Majority of the congenital hearing loss (80% are membranous malformations. Here the pathology involves inner ear hair cells. There is no gross bony abnormality and therefore, in these cases, high resolution computerized tomography and MRI of the temporal bone reveal normal findings. Remaining 20% have various malformations involving the bony labyrinth and therefore, can be radiologically demonstrated by CT and MRI. The latter group involves surgical challenges as well as problems in decision making. Some cases may be managed by hearing aid, some need cochlear implantation while some cases are candidates for an auditory brainstem implantation. During cochlear implantation, there may be facial nerve abnormalities, cerebrospinal fluid leakage, electrode misplacement or difficulty in finding the cochlea itself. During the surgery for inner ear malformations, surgeon must be ready to modify the surgical approach or choose special electrodes for surgery. In the present review article inner ear malformations are classified according to the differences observed in the cochlea. Hearing and language outcome after various implantation methods is closely related to the status of cochlear nerve and a practical classification of the cochlear nerve deficiency is also provided

  17. Real-time surgery simulation of intracranial aneurysm clipping with patient-specific geometries and haptic feedback

    Science.gov (United States)

    Fenz, Wolfgang; Dirnberger, Johannes

    2015-03-01

    Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.

  18. Using simulation to improve the cognitive and psychomotor skills of novice students in advanced laparoscopic surgery: a meta-analysis.

    Science.gov (United States)

    Al-Kadi, Azzam S; Donnon, Tyrone

    2013-01-01

    Advances in simulation technologies have enhanced the ability to introduce the teaching and learning of laparoscopic surgical skills to novice students. In this meta-analysis, a total of 18 randomized controlled studies were identified that specifically looked at training novices in comparison with a control group as it pertains to knowledge retention, time to completion and suturing and knotting skills. The combined random-effect sizes (ESs) showed that novice students who trained on laparoscopic simulators have considerably developed better laparoscopic suturing and knot tying skills (d = 1.96, p < 0.01), conducted fewer errors (d = 2.13, p < 0.01), retained more knowledge (d = 1.57, p < 0.01) than their respective control groups, and were significantly faster on time to completion (d = 1.98, p < 0.01). As illustrated in corresponding Forest plots, the majority of the primary study outcomes included in this meta-analysis show statistically significant support (p < 0.05) for the use of laparoscopic simulators for novice student training on both knowledge and advanced surgical skill development (28 of 35 outcomes, 80%). The findings of this meta-analysis support strongly the use of simulators for teaching laparoscopic surgery skills to novice students in surgical residency programs.

  19. Reconstruction of partially amputated external ear with costal cartilage graft: case report.

    Science.gov (United States)

    Brunelli, A; Bottini, D J; Cervelli, V; Cervelli, G; Grimaldi, M

    2004-06-01

    Many causes are responsible for secondary anomalies of the outer ear, such as: car accidents, sport- or work-related accidents, assaults, bites from animals or humans, benign or malignant tumours, burns and the effects of surgical interventions of the ear (plastic surgery on the ear or attempts at correction of primary malformations of the ear). The anatomical complexity of the ear makes its reconstruction particularly complicated with post-operative results that are often disappointing. The Authors describe their experience in the reconstruction of a partially amputated outer ear following a dog bite. The therapeutic protocol required various surgical stages. Initially, a cutaneous expander was applied at the level of the mastoid in order to ensure a sufficient quantity of local skin. The second stage was to remove cartilage from the ribs, followed by construction of a cartilaginous model of the ear and its insertion into the subcutaneous mastoid region after removal of the cutaneous expander and any residual ear cartilage. The last stage was to separate the neo-formed outer ear from the mastoid skin with the insertion of a cartilage graft to the posterior region of the reconstructed ear. This graft was covered by the occipital fascia rotated at 180 degrees and by a skin graft removed from the pubis. The postoperative result was satisfactory with recuperation of a good aesthetic appearance of the ear. Aim of the present report is to describe the surgical technique employed in the reconstruction of secondary anomalies of the ear and to highlight errors committed during this procedure. These considerations have allowed us to stress some fundamental elements in the reconstruction of the ear. In particular, the watershed was the awareness that we had to create a cartilaginous model that respected, as far as possible, the anatomy of the outer ear with all its ridges, trenches and cavities. This as well as ensuring a sufficient quantity of local skin in order to cover

  20. A RARE PRESENTATION OF FOREIGN BODY IN THE EAR WITH TRAUMATIC DISLOCATION OF THE INCUS IN A FEMALE CHILD: A CASE REPORT

    OpenAIRE

    Santhana Krishnan; Poornima S

    2014-01-01

    Foreign bodies in the middle ear are a rare occurrence. This is a case report of a 5 year old female , with plastic button in the left ear , with history of attempted removal using a metal hook , leading to subtotal perforation of the tympanic membrane and traumatic dislocation of the incus. On surgery a yellow colored plastic button , measuring about 1x 1 cm size was removed from middle ear by retroauricular approach . Myringostapediop...

  1. Virtual-reality simulation to assess performance in hip fracture surgery

    DEFF Research Database (Denmark)

    Pedersen, Poul; Palm, Henrik; Ringsted, Charlotte

    2014-01-01

    BACKGROUND AND PURPOSE: Internal fixation of hip fractures is a common and important procedure that orthopedic surgeons must master early in their career. Virtual-reality training could improve initial skills, and a simulation-based test would make it possible to ensure basic competency of junior...... experienced surgeon failing the test. INTERPRETATION: The simulation-based test was reliable and valid in our setting, and the pass/fail standard could discriminate between novices and experienced surgeons. Potentially, training and testing of future junior surgeons on a virtual-reality simulator could ensure...

  2. CT imaging of the internal human ear: Test of a high resolution scanner

    Energy Technology Data Exchange (ETDEWEB)

    Bettuzzi, M., E-mail: matteo.bettuzzi@unibo.it [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Brancaccio, R.; Morigi, M.P. [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Gallo, A. [Medicine Faculty, Magna Graecia University, Catanzaro and INFN Cosenza (Italy); Strolin, S.; Casali, F. [Department of Physics, University of Bologna and National Institute of Nuclear Physics Section of Bologna (Italy); Lamanna, Ernesto [Medicine Faculty, Magna Graecia University, Catanzaro and INFN Cosenza (Italy); Ariu, Marilu [CEFLA Dental Group, Imola (Italy)

    2011-08-21

    During the course of 2009, in the framework of a project supported by the National Institute of Nuclear Physics, a number of tests were carried out at the Department of Physics of the University of Bologna in order to achieve a good quality CT scan of the internal human ear. The work was carried out in collaboration with the local 'S. Orsola' Hospital in Bologna and a company (CEFLA) already involved in the production and commercialization of a CT scanner dedicated to dentistry. A laboratory scanner with a simple concept detector (CCD camera-lens-mirror-scintillator) was used to see to what extent it was possible to enhance the quality of a conventional CT scanner when examining the internal human ear. To test the system, some conventional measurements were made, such as the spatial resolution calculation with the MTF and dynamic range evaluation. Different scintillators were compared to select the most suitable for the purpose. With 0.5 mm thick structured cesium iodide and a field of view of 120x120 mm{sup 2}, a spatial resolution of 6.5l p/mm at 5% MTF was obtained. The CT of a pair of human head phantoms was performed at an energy of 120 kVp. The first phantom was a rough representation of the human head shape, with soft tissue made of coarse slabs of Lucite. Some inserts, like small aluminum cylinders and cubes, with 1 mm diameter drilled holes, were used to simulate the channels that one finds inside the human inner ear. The second phantom is a plastic PVC fused head with a real human cranium inside. The bones in the cranium are well conserved and the inner ear features, such as the cochlea and semicircular channels, are clearly detectable. After a number of CT tests we obtained good results as far as structural representation and channel detection are concerned. Some images of the 3D rendering of the CT volume are shown below. The doctors of the local hospital who followed our experimentation expressed their satisfaction. The CT was compared to a

  3. Carcinoid tumour of the middle ear

    LENUS (Irish Health Repository)

    Baig, Salman

    2012-09-01

    A case of middle ear mass in a young female from Ireland is described, who presented with left ear hearing loss and intermittent bloody discharge from the same ear. Examination under microscope revealed occlusive polyp in the left ear and a biopsy had been taken under general anaesthesia. Histopathology report described an adenoma \\/ carcinoid tumour of the middle ear confirmed by positive immunohistochemical staining. CT temporal bones revealed the extension of the disease. The patient underwent left tympanotomy and excision of the tumour. In general, these tumours are regarded as benign but may be mistaken for adenocarcinomas because of their histological heterogenecity.

  4. Evaluating Simulation in Training for Arthroscopic Knee Surgery: A Systematic Review of the Literature.

    Science.gov (United States)

    Hetaimish, Bandar; Elbadawi, Hussein; Ayeni, Olufemi R

    2016-06-01

    To evaluate the reported outcomes for measuring the effectiveness of simulation during knee arthroscopy training and determine the consistency of reporting and validation of simulation used in knee arthroscopy training. Four databases (MEDLINE, Embase, CINAHL, and Cochrane Central Register of Controlled Trials) were screened for studies involving knee arthroscopy simulation training. Inclusion and exclusion criteria were applied to the searched studies, and a quality assessment was completed for included studies. The reviewers searched the references list in each of the eligible studies to identify other relevant studies that was not captured by our search strategy. We identified 13 eligible studies. The mean number of participants per study was 24 (range: 9 to 42 participants). The 3 most commonly reported surgical skills were the mean time to perform the task (100%), the visualization and probing tasks (77%), and the number of cartilage collisions with measurement of the surgical force (46%). The most commonly described measurement instruments included the Simulation Built-In Scoring System (54%), motion analysis system (23%), and Basic Arthroscopic Knee Skill Scoring System global rating scale (15%). The most frequently reported type of validity for the simulator was construct validity (54%) and concurrent validity (31%). Moreover, construct validity (69%) and concurrent validity (54%) were the most commonly reported type of validity for the measurement instrument. There is significant variation in reported learning outcomes and measurement instruments for evaluating the effectiveness of knee arthroscopic simulation-based education. Despite this, time to perform a task was the most commonly reported skill-evaluating outcome of simulation. The included studies in this review were of variable strength in terms of their evidence and methodologic quality. This study highlights the need for consistent outcome reporting after arthroscopic simulation training. Level IV

  5. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  6. Cartilage island on stapes: autologous PORP in the hypoventilated middle ear.

    Science.gov (United States)

    Hess-Erga, Jeanette; Engelen, Bart Lambertus Henricus Jozef; Vassbotn, Flemming Slinning

    2017-04-01

    The most common technique in sound restoration of the middle ear is prosthetic surgery. Hypoventilation of the middle ear may cause adhesive otitis or atelectasis resulting in a higher risk of prosthetic extrusion rate and recurrence of the underlying cholesteatoma. We report long-term results using an island of tragal cartilage as an autologous PORP in selected patients with poor middle ear ventilation. Retrospective chart reviews were performed for procedures involving 52 patients between year 2000 and 2009. All patients that underwent surgery using tragal cartilage interposed between the suprastructure of the stapes and the tympanic membrane were included in this study. Audiological parameters using four frequencies, 0.5, 1, 2 and 3 kHz, according to AAO-HNS guidelines, were assessed pre-and postoperatively. The hearing results on different PTA frequencies were also investigated. We report long-term follow-up of patients with hypoventilated middle ear with a success rate of 71% (ABG <20%). With regards to the ABG, the low frequency component (5 and 1 kHz) showed a significantly (p < 0.05) larger improvement of mean values after surgery as compared to the high-frequency component (2 and 3 kHz). Cartilage island PORP on stapes is a stable and efficient method for selected patients with chronic middle ear disease.

  7. Imaging of the inner ear

    International Nuclear Information System (INIS)

    Casselman, J.W.; Bensimon, J.L.

    1997-01-01

    New computed tomography (CT) and magnetic resonance (MR) techniques allow more detailed anatomic studies of the inner ear. CT is still the best technique to study patients with fractures, congenital malformations and otodystrophies involving the inner ear. During recent years MR imaging has emerged as an excellent method to detect pathology in the internal auditory canal, membranous labyrinth and bony labyrinth and to characterize petrous apex lesions. MR has even proved its value in patients with fractures and congenital malformations making the diagnosis of, for instance, labyrinthine concussion and absence of the vestibulocochlear nerve possible. The diagnosis of acute/chronic labyrinthitis and intralabyrinthine tumors has also became possible. However, MR and CT are often complementary, as is the case in patients with mixed hearing loss, congenital malformations and petrous apex lesions. (orig.) [de

  8. Evaluation of a haptics-based virtual reality temporal bone simulator for anatomy and surgery training.

    Science.gov (United States)

    Fang, Te-Yung; Wang, Pa-Chun; Liu, Chih-Hsien; Su, Mu-Chun; Yeh, Shih-Ching

    2014-02-01

    Virtual reality simulation training may improve knowledge of anatomy and surgical skills. We evaluated a 3-dimensional, haptic, virtual reality temporal bone simulator for dissection training. The subjects were 7 otolaryngology residents (3 training sessions each) and 7 medical students (1 training session each). The virtual reality temporal bone simulation station included a computer with software that was linked to a force-feedback hand stylus, and the system recorded performance and collisions with vital anatomic structures. Subjects performed virtual reality dissections and completed questionnaires after the training sessions. Residents and students had favorable responses to most questions of the technology acceptance model (TAM) questionnaire. The average TAM scores were above neutral for residents and medical students in all domains, and the average TAM score for residents was significantly higher for the usefulness domain and lower for the playful domain than students. The average satisfaction questionnaire for residents showed that residents had greater overall satisfaction with cadaver temporal bone dissection training than training with the virtual reality simulator or plastic temporal bone. For medical students, the average comprehension score was significantly increased from before to after training for all anatomic structures. Medical students had significantly more collisions with the dura than residents. The residents had similar mean performance scores after the first and third training sessions for all dissection procedures. The virtual reality temporal bone simulator provided satisfactory training for otolaryngology residents and medical students. Copyright © 2013. Published by Elsevier Ireland Ltd.

  9. Foreign Body Granulomas Simulating Recurrent Tumors in Patients Following Colorectal Surgery for Carcinoma: a Report of Two Cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Kim, Il Young; Baek, Moo Joon; Cho, Hyun Deuk [Cheonan Hospital, Soonchunhyang University, Cheonan (Korea, Republic of)

    2009-06-15

    We report here two cases of foreign body granulomas that arose from the pelvic wall and liver, respectively, and simulated recurrent colorectal carcinomas in patients with a history of surgery. On contrast-enhanced CT and MR images, a pelvic wall mass appeared as a well-enhancing mass that had invaded the distal ureter, resulting in the development of hydronephrosis. In addition, a liver mass had a hypointense rim that corresponded to the fibrous wall on a T2-weighted MR image, and showed persistent peripheral enhancement that corresponded to the granulation tissues and fibrous wall on dynamic MR images. These lesions also displayed very intense homogeneous FDG uptake on PET/CT.

  10. Echocardiography for Intraoperative Decision Making in Mitral Valve Surgery-A Pilot Simulation-Based Training Module.

    Science.gov (United States)

    Morais, Rex Joseph; Ashokka, Balakrishnan; Paranjothy, Suresh; Siau, Chiang; Ti, Lian Kah

    2017-10-01

    Echocardiographic assessment of the repaired or replaced mitral valve intraoperatively involves making a high-impact joint decision with the surgeon, in a time-sensitive manner, in a dynamic clinical situation. These decisions have to take into account the degree of imperfection if any, the likelihood of obtaining a better result, the underlying condition of the patient, and the impact of a longer cardiopulmonary bypass period if the decision is made to reintervene. Traditional echocardiography teaching is limited in its ability to provide this training. The authors report the development and implementation of a training module simulating the dynamic clinical environment of a mitral valve surgery in progress and the critical echo-based intraoperative decision making involved in the assessment of the acceptability of the surgical result. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. [Hi-Fi simulation: Teaching crisis resource management to surgery residents].

    Science.gov (United States)

    Georgescu, Mihai; Tanoubi, Issam; Drolet, Pierre; Robitaille, Arnaud; Perron, Roger; Patenaude, Jean Victor

    2015-02-01

    High-fidelity (HiFi) simulation has shown its effectiveness for teaching crisis resource management (CRM) principles, and our institutional experience in this area is mainly with anesthesiology residents. We recently added to our postgraduate curriculum a new CRM course designed to cater to the specific needs of surgical residents. This short communication describes the experience of the University of Montreal Simulation Centre (Centre d'Apprentissage des Attitudes et Habiletés Cliniques CAAHC) regarding HiFi simulationbased CRM and communication skills teaching for surgical residents. Thirty residents agreed to participate in a simulation course with pre-established scenarios and educational CRM objectives on a voluntary basis. When surveyed immediately after the activity, all residents agreed that the educational objectives were well defined (80% "strongly agree" and 20% "agree"). The survey also showed that the course was well accepted by all participants (96% "strongly agree" and 4% "agree"). Further trials with randomized groups and more reliable assessment tools are needed to validate our results. Still, integrating HiFi simulation based CRM learning in the surgical residency curriculum seems like an interesting step.

  12. Cerebral Aneurysm Clipping Surgery Simulation Using Patient-Specific 3D Printing and Silicone Casting.

    Science.gov (United States)

    Ryan, Justin R; Almefty, Kaith K; Nakaji, Peter; Frakes, David H

    2016-04-01

    Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Man, mind, and machine: the past and future of virtual reality simulation in neurologic surgery.

    Science.gov (United States)

    Robison, R Aaron; Liu, Charles Y; Apuzzo, Michael L J

    2011-11-01

    To review virtual reality in neurosurgery, including the history of simulation and virtual reality and some of the current implementations; to examine some of the technical challenges involved; and to propose a potential paradigm for the development of virtual reality in neurosurgery going forward. A search was made on PubMed using key words surgical simulation, virtual reality, haptics, collision detection, and volumetric modeling to assess the current status of virtual reality in neurosurgery. Based on previous results, investigators extrapolated the possible integration of existing efforts and potential future directions. Simulation has a rich history in surgical training, and there are numerous currently existing applications and systems that involve virtual reality. All existing applications are limited to specific task-oriented functions and typically sacrifice visual realism for real-time interactivity or vice versa, owing to numerous technical challenges in rendering a virtual space in real time, including graphic and tissue modeling, collision detection, and direction of the haptic interface. With ongoing technical advancements in computer hardware and graphic and physical rendering, incremental or modular development of a fully immersive, multipurpose virtual reality neurosurgical simulator is feasible. The use of virtual reality in neurosurgery is predicted to change the nature of neurosurgical education, and to play an increased role in surgical rehearsal and the continuing education and credentialing of surgical practitioners. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Comparison of different sets of instruments for laparoendoscopic single-site surgery in a surgical simulator with novices.

    Science.gov (United States)

    Wang, Dong; Shi, Long-Qing; Wang, Jing-Min; Jiang, Xiao-Hua; Ji, Zhen-Ling

    2016-04-01

    Given the parallel entry of working instruments through a single incision in laparoendoscopic single-site surgery, loss of triangulation in the abdominal cavity and counteracting movements of the instruments are inevitable obstacles. Some specially designed devices have emerged to ameliorate these challenges. Twenty-four novice participants were randomized into four groups using assigned instruments, conventional straight instruments, single-curved instruments, double-curved instruments and articulating instruments, respectively, to perform two basic tasks (peg transferring and pattern cutting) 14 times in a modified simulator. A test of the tasks and a resection of the intestine segment of a rat were performed. The task scores and evaluation of intraoperative skills during the resection of the intestine segment were recorded. The instrument of modified National Aeronautics and Space Administration Task Load Index (NASA-TLX) was completed. The task scores of the groups using single-curved instruments and articulating instruments were better than the other two groups on the simulator tasks, consistent with the evaluation of intraoperative skills during the resection of intestine segment. As the proficiency with the instruments increased, the task scores improved, as demonstrated by the learning curve. The workload measured by the modified NASA-TLX tool demonstrated that the groups using articulating instruments and double-curved instruments had a heavier workload in most of the categories compared with the other two groups. Single-curved and articulating instruments are more effective than conventional straight and double-curved devices, and are favourable in laparoendoscopic single-site surgery for novice learners. © 2013 Royal Australasian College of Surgeons.

  15. Construction of a Urologic Robotic Surgery Training Curriculum: How Many Simulator Sessions Are Required for Residents to Achieve Proficiency?

    Science.gov (United States)

    Wiener, Scott; Haddock, Peter; Shichman, Steven; Dorin, Ryan

    2015-11-01

    To define the time needed by urology residents to attain proficiency in computer-aided robotic surgery to aid in the refinement of a robotic surgery simulation curriculum. We undertook a retrospective review of robotic skills training data acquired during January 2012 to December 2014 from junior (postgraduate year [PGY] 2-3) and senior (PGY4-5) urology residents using the da Vinci Skills Simulator. We determined the number of training sessions attended and the level of proficiency achieved by junior and senior residents in attempting 11 basic or 6 advanced tasks, respectively. Junior residents successfully completed 9.9 ± 1.8 tasks, with 62.5% completing all 11 basic tasks. The maximal cumulative success rate of junior residents completing basic tasks was 89.8%, which was achieved within 7.0 ± 1.5 hours of training. Of senior residents, 75% successfully completed all six advanced tasks. Senior residents attended 6.3 ± 3.5 hours of training during which 5.1 ± 1.6 tasks were completed. The maximal cumulative success rate of senior residents completing advanced tasks was 85.4%. When designing and implementing an effective robotic surgical training curriculum, an allocation of 10 hours of training may be optimal to allow junior and senior residents to achieve an acceptable level of surgical proficiency in basic and advanced robotic surgical skills, respectively. These data help guide the design and scheduling of a residents training curriculum within the time constraints of a resident's workload.

  16. Augmented reality fluoroscopy simulation of the guide-wire insertion in DHS surgery: A proof of concept study.

    Science.gov (United States)

    van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A

    2018-05-01

    Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on

  17. Simulated lumbar minimally invasive surgery educational model with didactic and technical components.

    Science.gov (United States)

    Chitale, Rohan; Ghobrial, George M; Lobel, Darlene; Harrop, James

    2013-10-01

    The learning and development of technical skills are paramount for neurosurgical trainees. External influences and a need for maximizing efficiency and proficiency have encouraged advancements in simulator-based learning models. To confirm the importance of establishing an educational curriculum for teaching minimally invasive techniques of pedicle screw placement using a computer-enhanced physical model of percutaneous pedicle screw placement with simultaneous didactic and technical components. A 2-hour educational curriculum was created to educate neurosurgical residents on anatomy, pathophysiology, and technical aspects associated with image-guided pedicle screw placement. Predidactic and postdidactic practical and written scores were analyzed and compared. Scores were calculated for each participant on the basis of the optimal pedicle screw starting point and trajectory for both fluoroscopy and computed tomographic navigation. Eight trainees participated in this module. Average mean scores on the written didactic test improved from 78% to 100%. The technical component scores for fluoroscopic guidance improved from 58.8 to 52.9. Technical score for computed tomography-navigated guidance also improved from 28.3 to 26.6. Didactic and technical quantitative scores with a simulator-based educational curriculum improved objectively measured resident performance. A minimally invasive spine simulation model and curriculum may serve a valuable function in the education of neurosurgical residents and outcomes for patients.

  18. Patient Specific Multiscale Simulations of Blood Flow in Coronary Artery Bypass Surgery

    Science.gov (United States)

    Bangalore Ramachandra, Abhay; Sankaran, Sethuraman; Kahn, Andrew M.; Marsden, Alison L.

    2013-11-01

    Coronary artery bypass surgery is performed to revascularize blocked coronary arteries in roughly 400,000 patients per year in the US.While arterial grafts offer superior patency, vein grafts are used in more than 70% of procedures, as most patients require multiple grafts. Vein graft failure (approx. 50% within 10 years) remains a major clinical issue. Mounting evidence suggests that hemodynamics plays a key role as a mechano-biological stimulus contributing to graft failure. However, quantifying relevant hemodynamic quantities (e.g. wall shear stress) invivo is not possible directly using clinical imaging techniques. We numerically compute graft hemodynamics in a cohort of 3-D patient specific models using a stabilized finite element method. The 3D flow domain is coupled to a 0D lumped parameter circulatory model. Boundary conditions are tuned to match patient specific blood pressures, stroke volumes & heart rates. Results reproduce clinically observed coronary flow waveforms. We quantify differences in multiple hemodynamic quantities between arterial & venous grafts & discuss possible correlations between graft hemodynamics & clinically observed graft failure.Such correlations will provide further insight into mechanisms of graft failure and may lead to improved clinical outcomes.

  19. DEVELOPMENT OF PLASTIC SURGERY.

    Science.gov (United States)

    Pećanac, Marija Đ

    2015-01-01

    Plastic surgery is a medical specialty dealing with corrections of defects, improvements in appearance and restoration of lost function. Ancient times. The first recorded account of reconstructive plastic surgery was found in ancient Indian Sanskrit texts, which described reconstructive surgeries of the nose and ears. In ancient Greece and Rome, many medicine men performed simple plastic cosmetic surgeries to repair damaged parts of the body caused by war mutilation, punishment or humiliation. In the Middle Ages, the development of all medical braches, including plastic surgery was hindered. New age. The interest in surgical reconstruction of mutilated body parts was renewed in the XVIII century by a great number of enthusiastic and charismatic surgeons, who mastered surgical disciplines and became true artists that created new forms. Modern era. In the XX century, plastic surgery developed as a modern branch in medicine including many types of reconstructive surgery, hand, head and neck surgery, microsurgery and replantation, treatment of burns and their sequelae, and esthetic surgery. Contemporary and future plastic surgery will continue to evolve and improve with regenerative medicine and tissue engineering resulting in a lot of benefits to be gained by patients in reconstruction after body trauma, oncology amputation, and for congenital disfigurement and dysfunction.

  20. A Tissue Relevance and Meshing Method for Computing Patient-Specific Anatomical Models in Endoscopic Sinus Surgery Simulation

    Science.gov (United States)

    Audette, M. A.; Hertel, I.; Burgert, O.; Strauss, G.

    This paper presents on-going work on a method for determining which subvolumes of a patient-specific tissue map, extracted from CT data of the head, are relevant to simulating endoscopic sinus surgery of that individual, and for decomposing these relevant tissues into triangles and tetrahedra whose mesh size is well controlled. The overall goal is to limit the complexity of the real-time biomechanical interaction while ensuring the clinical relevance of the simulation. Relevant tissues are determined as the union of the pathology present in the patient, of critical tissues deemed to be near the intended surgical path or pathology, and of bone and soft tissue near the intended path, pathology or critical tissues. The processing of tissues, prior to meshing, is based on the Fast Marching method applied under various guises, in a conditional manner that is related to tissue classes. The meshing is based on an adaptation of a meshing method of ours, which combines the Marching Tetrahedra method and the discrete Simplex mesh surface model to produce a topologically faithful surface mesh with well controlled edge and face size as a first stage, and Almost-regular Tetrahedralization of the same prescribed mesh size as a last stage.

  1. Internally Coupled Ears in Living Mammals

    OpenAIRE

    Mason, Matthew James

    2015-01-01

    It is generally held that the right and left middle ears of mammals are acoustically isolated from each other, such that mammals must rely on neural computation to derive sound localisation cues. There are, however, some unusual species in which the middle ear cavities intercommunicate, in which case each ear might be able to act as a pressure-difference receiver. This could improve sound localisation at lower frequencies. The platypus Ornithorhynchus is apparently unique among mammals in tha...

  2. In-the-Ear Circular-Shaped Balanced Inverted-A Antenna for Hearing Instruments

    DEFF Research Database (Denmark)

    Kammersgaard, Nikolaj Peter Iversen; Kvist, Søren Helstrup; Thaysen, Jesper

    2016-01-01

    for impedance matching. It is self-resonant and well matched in the entire ISM band from 2.40 GHz to 2.48 GHz. The simulated and measured peak ear-to-ear path gain |S21| is −74.5 dB and −72.9 dB, respectively. The radiation pattern of the antenna is analyzed and the implications of the radiation pattern...

  3. Simulation-based otolaryngology - head and neck surgery boot camp: 'how I do it'.

    Science.gov (United States)

    Chin, C J; Chin, C A; Roth, K; Rotenberg, B W; Fung, K

    2016-03-01

    In otolaryngology, surgical emergencies can occur at any time. An annual surgical training camp (or 'boot camp') offers junior residents from across North America the opportunity to learn and practice these skills in a safe environment. The goals of this study were to describe the set-up and execution of a simulation-based otolaryngology boot camp and to determine participants' confidence in performing routine and emergency on-call procedures in stressful situations before and after the boot camp. There were three main components of the boot camp: task trainers, simulations and an interactive panel discussion. Surveys were given to participants before and after the boot camp, and their confidence in performing the different tasks was assessed via multiple t-tests. Participants comprised 22 residents from 12 different universities; 10 of these completed both boot camp surveys. Of the nine tasks, the residents reported a significant improvement in confidence levels for six, including surgical airway and orbital haematoma management. An otolaryngology boot camp gives residents the chance to learn and practice emergency skills before encountering the emergencies in everyday practice. Their confidence in multiple skillsets was significantly improved after the boot camp. Given the shift towards competency-based learning in medical training, this study has implications for all surgical and procedural specialties.

  4. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery.

    Science.gov (United States)

    Suenaga, Hideyuki; Taniguchi, Asako; Yonenaga, Kazumichi; Hoshi, Kazuto; Takato, Tsuyoshi

    2016-01-01

    Computer-assisted preoperative simulation surgery is employed to plan and interact with the 3D images during the orthognathic procedure. It is useful for positioning and fixation of maxilla by a plate. We report a case of maxillary retrusion by a bilateral cleft lip and palate, in which a 2-stage orthognathic procedure (maxillary advancement by distraction technique and mandibular setback surgery) was performed following a computer-assisted preoperative simulation planning to achieve the positioning and fixation of the plate. A high accuracy was achieved in the present case. A 21-year-old male patient presented to our department with a complaint of maxillary retrusion following bilateral cleft lip and palate. Computer-assisted preoperative simulation with 2-stage orthognathic procedure using distraction technique and mandibular setback surgery was planned. The preoperative planning of the procedure resulted in good aesthetic outcomes. The error of the maxillary position was less than 1mm. The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. An Effective 3D Ear Acquisition System.

    Directory of Open Access Journals (Sweden)

    Yahui Liu

    Full Text Available The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  6. Geometric and mechanical evaluation of 3D-printing materials for skull base anatomical education and endoscopic surgery simulation - A first step to create reliable customized simulators.

    Directory of Open Access Journals (Sweden)

    Valentin Favier

    Full Text Available Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training.Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor, polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling.All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error. Local accuracy was better in polycarbonate (0.09mm and polyamide (0.15mm than in Multicolor (0.90mm and resin (0.86mm. Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6-3.5 times higher than in bone. For polycarbonate, forces applied were 1.6-2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor.Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety.

  7. Geometric and mechanical evaluation of 3D-printing materials for skull base anatomical education and endoscopic surgery simulation - A first step to create reliable customized simulators.

    Science.gov (United States)

    Favier, Valentin; Zemiti, Nabil; Caravaca Mora, Oscar; Subsol, Gérard; Captier, Guillaume; Lebrun, Renaud; Crampette, Louis; Mondain, Michel; Gilles, Benjamin

    2017-01-01

    Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor), polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling. All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error). Local accuracy was better in polycarbonate (0.09mm) and polyamide (0.15mm) than in Multicolor (0.90mm) and resin (0.86mm). Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6-3.5 times higher than in bone. For polycarbonate, forces applied were 1.6-2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor. Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety.

  8. Assessment of refractive astigmatism and simulated therapeutic refractive surgery strategies in coma-like-aberrations-dominant corneal optics.

    Science.gov (United States)

    Zhou, Wen; Stojanovic, Aleksandar; Utheim, Tor Paaske

    2016-01-01

    The aim of the study is to raise the awareness of the influence of coma-like higher-order aberrations (HOAs) on power and orientation of refractive astigmatism (RA) and to explore how to account for that influence in the planning of topography-guided refractive surgery in eyes with coma-like-aberrations-dominant corneal optics. Eleven eyes with coma-like-aberrations-dominant corneal optics and with low lenticular astigmatism (LA) were selected for astigmatism analysis and for treatment simulations with topography-guided custom ablation. Vector analysis was used to evaluate the contribution of coma-like corneal HOAs to RA. Two different strategies were used for simulated treatments aiming to regularize irregular corneal optics: With both strategies correction of anterior corneal surface irregularities (corneal HOAs) were intended. Correction of total corneal astigmatism (TCA) and RA was intended as well with strategies 1 and 2, respectively. Axis of discrepant astigmatism (RA minus TCA minus LA) correlated strongly with axis of coma. Vertical coma influenced RA by canceling the effect of the with-the-rule astigmatism and increasing the effect of the against-the-rule astigmatism. After simulated correction of anterior corneal HOAs along with TCA and RA (strategies 1 and 2), only a small amount of anterior corneal astigmatism (ACA) and no TCA remained after strategy 1, while considerable amount of ACA and TCA remained after strategy 2. Coma-like corneal aberrations seem to contribute a considerable astigmatic component to RA in eyes with coma-like-aberrations dominant corneal optics. If topography-guided ablation is programmed to correct the corneal HOAs and RA, the astigmatic component caused by the coma-like corneal HOAs will be treated twice and will result in induced astigmatism. Disregarding RA and treating TCA along with the corneal HOAs is recommended instead.

  9. The role of the tensor veli palatini muscle in the development of cleft palate-associated middle ear problems.

    Science.gov (United States)

    Heidsieck, David S P; Smarius, Bram J A; Oomen, Karin P Q; Breugem, Corstiaan C

    2016-09-01

    Otitis media with effusion is common in infants with an unrepaired cleft palate. Although its prevalence is reduced after cleft surgery, many children continue to suffer from middle ear problems during childhood. While the tensor veli palatini muscle is thought to be involved in middle ear ventilation, evidence about its exact anatomy, function, and role in cleft palate surgery is limited. This study aimed to perform a thorough review of the literature on (1) the role of the tensor veli palatini muscle in the Eustachian tube opening and middle ear ventilation, (2) anatomical anomalies in cleft palate infants related to middle ear disease, and (3) their implications for surgical techniques used in cleft palate repair. A literature search on the MEDLINE database was performed using a combination of the keywords "tensor veli palatini muscle," "Eustachian tube," "otitis media with effusion," and "cleft palate." Several studies confirm the important role of the tensor veli palatini muscle in the Eustachian tube opening mechanism. Maintaining the integrity of the tensor veli palatini muscle during cleft palate surgery seems to improve long-term otological outcome. However, anatomical variations in cleft palate children may alter the effect of the tensor veli palatini muscle on the Eustachian tube's dilatation mechanism. More research is warranted to clarify the role of the tensor veli palatini muscle in cleft palate-associated Eustachian tube dysfunction and development of middle ear problems. Optimized surgical management of cleft palate could potentially reduce associated middle ear problems.

  10. Preoperative diagnosis and surgical strategy in congenital auditory ossicular malformation of 26 ears

    International Nuclear Information System (INIS)

    Kanazawa, Yuji; Naito, Yasushi; Shinohara, Shogo; Fujiwara, Keizo; Kikuchi, Masahiro; Yamazaki, Hiroshi; Kurihara, Risa; Kishimoto, Ippei

    2012-01-01

    We retrospectively analyzed 26 ears of 21 subjects having auditory ossicular malformation and who had undergone auditory reconstruction between April 2004 and December 2010 at our clinic. We checked preoperative condition, pathological classification, surgical procedure, and hearing improvement. We could predict pathological conditions precisely from preoperative computed tomography (CT), including incudostapedial disconnection (9/12, 75%) and malleus and/or incus fixation (7/12, 58%), which tended to be present in external ear malformation, and stapes footplate fixation (0/12, 0%). We could not, however, predict complex malformation (0/8, 0%). Overall success was 90% (18/20) in the 20 ears observed for at least 1 year. In the 2 ears without improved hearing, the first had congenital cholesteatoma and no stapes superstructure, was treated with type IV tympanoplasty. The second had malleus, incus, and stapes fixation and discontinuity between the incus and stapes, and was treated with type III tympanoplasty and stapes mobilization. Preoperative diagnosis is difficult in mixed congenital auditory ossicular malformation, especially stapes footplate fixation, possibly requiring unexpected procedures, with a poor hearing outcome. Preoperative status must thus be evaluated precisely using hearing, tympanometry, acoustic reflex test, and CT. Temporal bone CT and external ear findings are useful in diagnosing middle-ear malformation. Subjects' informed consent should also be obtained due to the possible need for changing procedure based on findings during surgery. (author)

  11. Otosclerosis surgery: approaches, profits and complications.

    Science.gov (United States)

    Japaridze, Sh; Lomidze, L; Jashi, M; Kekelidze, I; Gegenava, Kh

    2009-05-01

    A systematic analysis of stapedoplasty output in otosclerosis cases was carried out. The operations were done during the period of 2005-2008 years at the Department of Otorhinolaryngology of the Tbilisi State Medical University. From the overall number of 107 patients, 78 were females and 29 males, 72.9% and 27.1%, respectively. The ages ranged from 16 to 57 years. The mean age was 35 years. The conductive and mixed forms of hearing losses were diagnosed in 70 and 37 cases, 65.4% and 34.6%, respectively. Right ear was operated in 46 patients, left ear in 57, and both ears in four, 43.3%, 53.0%, and 3.7%, respectively. 111 ears have been cured thus in sum. Intumescences of external ear tube were observed during the operation in 22 patients, 20.6%. In 7, 6.5%, the facial nerve was located downward. Particularly abnormal placement of the facial nerve was the case in two patients, 1.9%. The endaural approach has been proved to own advantages over the transmeatal one. The data generally confirmed that stapedotomy, as compared to stapedectomy, is a better choice for the surgery output. In beneficial cases the air/bone gaps after the operation closed totally or nearly totally. Such a proper outcome was reached in 93 out of 111 ears operated, 83.8%. In most of remainder ears the gaps after the operation narrowed significantly but far not completely. The definite surgery failure happened in one case only, 0.9%. To balance the preserved middle-ear problems in non-perfect surgery cases, the hearing aids of bone-conduction types have been recommended. In mixed otosclerosis cases, conversely, the aids of air-conduction types were advised to overcome the coexisted inner-ear pathologies.

  12. Simulation in paediatric urology and surgery. Part 1: An overview of educational theory.

    Science.gov (United States)

    Nataraja, Ramesh M; Webb, Nathalie; Lopez, Pedro-Jose

    2018-03-01

    Surgical training has changed radically in the last few decades. The traditional Halstedian model of time-bound apprenticeship has been replaced with competency-based training. Advanced understanding of mastery learning principles has vastly altered educational methodology in surgical training, in terms of instructional design, delivery of educational content, assessment of learning, and programmatic evaluation. As part of this educational revolution, fundamentals of simulation-based education have been adopted into all levels and aspects of surgical training, requiring an understanding of concepts of fidelity and realism and the impact they have on learning. There are many educational principles and theories that can help clinical teachers understand the way that their trainees learn. In the acquisition of surgical expertise, concepts of mastery learning, deliberate practice, and experiential learning are particularly important. Furthermore, surgical teachers need to understand the principles of effective feedback, which is essential to all forms of skills learning. This article, the first of two papers, presents an overview of relevant learning theory for the busy paediatric surgeon and urologist. Seeking to introduce the concepts underpinning current changes in surgical education and training, providing practical tips to optimise teaching endeavours. Copyright © 2018 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  13. Objective Audiometry using Ear-EEG

    DEFF Research Database (Denmark)

    Christensen, Christian Bech; Kidmose, Preben

    Recently, a novel electroencephalographic (EEG) method called ear-EEG [1], that enable recording of auditory evoked potentials (AEPs) from a personalized earpiece was introduced. Initial investigations show that well established AEPs, such as ASSR and P1-N1-P2 complex can be observed from ear-EEG...

  14. Congenital malformation of inner ear, single cavity

    International Nuclear Information System (INIS)

    Torres Pazmino, Julio Cesar; Marrugo Pardo, Gilberto Eduardo

    2010-01-01

    Congenital malformations of the inner ear are rare conditions, but their detection requires high diagnostic accuracy. In this report we describe the case of a patient with single or common cavity, discuss the corresponding radiological images, describe the treatment of this patient with a cochlear implant, and review the classification and differential diagnosis of the other anomalies of the inner ear.

  15. Interconnections between the Ears in Nonmammalian Vertebrates

    DEFF Research Database (Denmark)

    Feng, Albert S.; Christensen-Dalsgaard, J.

    2010-01-01

    Many of the nonmammalian vertebrates (anurans, lizards, crocodiles, and some bird species) have large, continuous air spaces connecting the middle ears and acoustically coupling the eardrums. Acoustical coupling leads to strongly enhanced directionality of the ear at frequencies where diffraction...... cues are negligible in small-sized animals. The chapter reviews the peripheral basis of directionality in these animal groups....

  16. Coupled ears in lizards and crocodilians

    DEFF Research Database (Denmark)

    Carr, Catherine E; Christensen-Dalsgaard, Jakob; Bierman, Hilary

    2016-01-01

    Lizard ears are coupled across the pharynx, and are very directional. In consequence all auditory responses should be directional, without a requirement for computation of sound source location. Crocodilian ears are connected through sinuses, and thus less tightly coupled. Coupling may improve th...... range is reviewed in the light of current theories of sound localization....

  17. Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery.

    Science.gov (United States)

    Camps, Vicente J; Miret, Juan J; García, Celia; Tolosa, Angel; Piñero, David P

    2018-04-01

    To simulate the optical performance of three presbyopia-correcting intraocular lenses (IOLs) implanted in eyes with previous laser refractive surgery. A simulation of the through-focus modulation transfer function (MTF) was performed for three presbyopia-correcting IOLs (Mplus, Oculentis GmbH, Berlin, Germany; Symfony, Johnson & Johnson Vision, Santa Ana, CA; and Mini Well, SIFI S.p.A., Lavinaio, Italy) in one eye with previous myopic LASIK and another with hyperopic LASIK. Real topographic data and the wavefront aberration profile of each IOL obtained with a Hartmann-Shack sensor were used. In the eye with myopic LASIK, all IOLs lost optical quality at near and intermediate distances for 4- and 4.7-mm pupil size. For 3-mm pupil size, the Mini Well IOL showed the best intermediate and near MTF and maintained the far focus independently of the pupil. In the eye with hyperopic LASIK, the Mini Well IOL showed an intermediate, distance, and -4.00-diopter (D) foci for all pupils. The Symfony IOL showed a depth of focus at far and intermediate distance for 3-mm and a focus at -2.50 D in the rest. The Mplus showed a focus of -4.50 and -3.00 D for the 3- and 4-mm pupil, respectively. The Mini Well and Symfony IOLs seem to work better than the Mplus IOL in eyes with previous myopic LASIK. With previous hyperopic LASIK, the Mini Well IOL seems to be able to provide acceptable near, intermediate, and far foci for all pupil sizes. These findings should be confirmed in future clinical studies. [J Refract Surg. 2018;34(4):222-227.]. Copyright 2018, SLACK Incorporated.

  18. The utility of sparse 2D fully electronically steerable focused ultrasound phased arrays for thermal surgery: a simulation study

    International Nuclear Information System (INIS)

    Ellens, Nicholas; Pulkkinen, Aki; Song Junho; Hynynen, Kullervo

    2011-01-01

    Sparse arrays are widely used in diagnostic ultrasound for their strong performance and relative technical simplicity. This simulation study assessed the efficacy of phased arrays of varied sparseness for thermal surgery, especially with regard to power consumption and near-field heating. It employs a linear ultrasound propagation model and a semi-analytical solution to the Pennes' bioheat transfer equation. The basic design had 4912 cylindrical transducers (500 kHz) arranged on a flat 12 cm disk (1.5 mm spacing). This array was compared to randomly-thinned sparse arrays with 75%, 50% and 25% populations. Temperature elevations of 60 and 70 deg. C were induced in sonication times of 5-20 s, at foci spanning depths of 50-150 mm and radii of 0-60 mm. The sparse arrays produced nearly indistinguishable focal patterns but, averaged across the foci, required 132%, 200% and 393% of the power of the full array, respectively, applied through fewer transducer elements. Comparable results were found at 1 MHz from equivalent arrays. Simulated lesions were formed (thermal dose ≥ 240 equivalent minutes at 43 deg. C (T 43 )) and 'transition' and 'unsafe' regions (both defined as 5 min 43 < 240 min) were identified, the former immediately surrounding the lesion and the latter anywhere else. At a depth of 100 mm, sparse arrays were found to produce comparable lesions to the full array at the focus, but 'unsafe', over-heated near-field regions after some ablated lesion volume: about 12 mL for the 25% array, around 100 mL for the 50% array, while the 75% and full arrays produced 150 mL lesions safely.

  19. [Team training and assessment in mixed reality-based simulated operating room : Current state of research in the field of simulation in spine surgery exemplified by the ATMEOS project].

    Science.gov (United States)

    Stefan, P; Pfandler, M; Wucherer, P; Habert, S; Fürmetz, J; Weidert, S; Euler, E; Eck, U; Lazarovici, M; Weigl, M; Navab, N

    2018-04-01

    Surgical simulators are being increasingly used as an attractive alternative to clinical training in addition to conventional animal models and human specimens. Typically, surgical simulation technology is designed for the purpose of teaching technical surgical skills (so-called task trainers). Simulator training in surgery is therefore in general limited to the individual training of the surgeon and disregards the participation of the rest of the surgical team. The objective of the project Assessment and Training of Medical Experts based on Objective Standards (ATMEOS) is to develop an immersive simulated operating room environment that enables the training and assessment of multidisciplinary surgical teams under various conditions. Using a mixed reality approach, a synthetic patient model, real surgical instruments and radiation-free virtual X‑ray imaging are combined into a simulation of spinal surgery. In previous research studies, the concept was evaluated in terms of realism, plausibility and immersiveness. In the current research, assessment measurements for technical and non-technical skills are developed and evaluated. The aim is to observe multidisciplinary surgical teams in the simulated operating room during minimally invasive spinal surgery and objectively assess the performance of the individual team members and the entire team. Moreover, the effectiveness of training methods and surgical techniques or success critical factors, e. g. management of crisis situations, can be captured and objectively assessed in the controlled environment.

  20. Computer-assisted surgery simulations and directed practice of total knee arthroplasty: educational benefits to the trainee.

    Science.gov (United States)

    Myden, C A; Anglin, C; Kopp, G D; Hutchison, C R

    2012-01-01

    Orthopaedic residents typically learn to perform total knee arthroplasty (TKA) through an apprenticeship-type model, which is a necessarily slow process. Surgical skills courses, using artificial bones, have been shown to improve technical and cognitive skills significantly within a couple of days. The addition of computer-assisted surgery (CAS) simulations challenges the participants to consider the same task in a different context, promoting cognitive flexibility. We designed a hands-on educational intervention for junior residents with a conventional tibiofemoral TKA station, two different tibiofemoral CAS stations, and a CAS and conventional patellar resection station, including both qualitative and quantitative analyses. Qualitatively, structured interviews before and after the course were analyzed for recurring themes. Quantitatively, subjects were evaluated on their technical skills before and after the course, and on a multiple-choice knowledge test and error detection test after the course, in comparison to senior residents who performed only the testing. Four themes emerged: confidence, awareness, deepening knowledge and changed perspectives. The residents' attitudes to CAS changed from negative before the course to neutral or positive afterwards. The junior resident group completed 23% of tasks in the pre-course skills test and 75% of tasks on the post-test (peducational interventions, promoting cognitive flexibility, would benefit trainees, attending surgeons, the healthcare system and patients.

  1. Accuracy of a Computer-Aided Surgical Simulation (CASS) Protocol for Orthognathic Surgery: A Prospective Multicenter Study

    Science.gov (United States)

    Hsu, Sam Sheng-Pin; Gateno, Jaime; Bell, R. Bryan; Hirsch, David L.; Markiewicz, Michael R.; Teichgraeber, John F.; Zhou, Xiaobo; Xia, James J.

    2012-01-01

    Purpose The purpose of this prospective multicenter study was to assess the accuracy of a computer-aided surgical simulation (CASS) protocol for orthognathic surgery. Materials and Methods The accuracy of the CASS protocol was assessed by comparing planned and postoperative outcomes of 65 consecutive patients enrolled from 3 centers. Computer-generated surgical splints were used for all patients. For the genioplasty, one center utilized computer-generated chin templates to reposition the chin segment only for patients with asymmetry. Standard intraoperative measurements were utilized without the chin templates for the remaining patients. The primary outcome measurements were linear and angular differences for the maxilla, mandible and chin when the planned and postoperative models were registered at the cranium. The secondary outcome measurements were: maxillary dental midline difference between the planned and postoperative positions; and linear and angular differences of the chin segment between the groups with and without the use of the template. The latter was measured when the planned and postoperative models were registered at mandibular body. Statistical analyses were performed, and the accuracy was reported using root mean square deviation (RMSD) and Bland and Altman's method for assessing measurement agreement. Results In the primary outcome measurements, there was no statistically significant difference among the 3 centers for the maxilla and mandible. The largest RMSD was 1.0mm and 1.5° for the maxilla, and 1.1mm and 1.8° for the mandible. For the chin, there was a statistically significant difference between the groups with and without the use of the chin template. The chin template group showed excellent accuracy with largest positional RMSD of 1.0mm and the largest orientational RSMD of 2.2°. However, larger variances were observed in the group not using the chin template. This was significant in anteroposterior and superoinferior directions, as in

  2. Acceleration induced water removal from ear canals.

    Science.gov (United States)

    Kang, Hosung; Averett, Katelee; Jung, Sunghwan

    2017-11-01

    Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.

  3. Innate immune defense in the inner ear - mucines are expressed by the human endolymphatic sac

    DEFF Research Database (Denmark)

    Møller, Martin N; Kirkeby, Svend; Cayé-Thomasen, Per

    2017-01-01

    The human endolymphatic sac has been shown recently to have immunological capacities and has thus been proposed as the main entity protecting the inner ear from pathogen invasion, equivalent to mucosa-associated lymphoid tissue (MALT). Although the sac expresses molecules of the innate immune...... system, the potential expression of members of the important mucin family has not been detailed. Thus, this paper explores endolymphatic sac expression of a number of mucins and mucin precursors. Twelve fresh tissue samples from the human endolymphatic sac were obtained during translabyrinthine surgery...... immunological tissue structure of the inner ear, equivalent to MALT in other organs. The mucins may also play a role in the formation and continuous homeostasis of the inner ear fluids, as well as the pathogenesis of Meniere's disease....

  4. Validation of virtual reality simulators: Key to the successful integration of a novel teaching technology into minimal access surgery

    NARCIS (Netherlands)

    Schijven, Marlies P.; Jakimowicz, Jack J.

    2005-01-01

    Minimal access surgery (MAS) requires additional training in the surgical curriculum, as skills needed to perform MAS are quite different from those used in open surgery. Moreover, residents do not seem to experience ample opportunity to gain such skills in the current surgical curriculum. Virtual

  5. EARS: Electronic Access to Reference Service.

    Science.gov (United States)

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  6. Robotic surgery training with commercially available simulation systems in 2011: a current review and practice pattern survey from the society of urologic robotic surgeons.

    Science.gov (United States)

    Lallas, Costas D; Davis, John W

    2012-03-01

    Virtual reality (VR) simulation has the potential to standardize surgical training for robotic surgery. We sought to evaluate all commercially available VR robotic simulators. A MEDLINE(®) literature search was performed of all applicable keywords. Available VR simulators were evaluated with regard to face, content, and construct validation. Additionally, a survey was e-mailed to all members of the Endourological Society, querying the pervasiveness of VR simulators in robotic surgical training. Finally, each company was e-mailed to ask for a price quote for their respective system. There are four VR robotic surgical simulators currently available: RoSS™, dV-Trainer™, SEP Robot™, and da Vinci(®) Skills Simulator™. Each system is represented in the literature and all possess varying degrees of face, content, and construct validity. Although all systems have basic skill sets with performance analysis and metrics software, most do not contain procedural components. When evaluating the results of our survey, most respondents did not possess a VR simulator although almost all believed there to be great potential for these devices in robotic surgical training. With the exception of the SEP Robot, all VR simulators are similar in price. VR simulators have a definite role in the future of robotic surgical training. Although the simulators target technical components of training, their largest impact will be appreciated when incorporated into a comprehensive educational curriculum.

  7. Activation of NLRP3 inflammasome in human middle ear cholesteatoma and chronic otitis media.

    Science.gov (United States)

    Kariya, Shin; Okano, Mitsuhiro; Zhao, Pengfei; Kataoka, Yuko; Yoshinobu, Junko; Maeda, Yukihide; Ishihara, Hisashi; Higaki, Takaya; Nishizaki, Kazunori

    2016-01-01

    The nucleotide-binding oligomerization domain-like receptor protein 3 (NLRP3) inflammasome plays an important role in the pathogenesis of middle ear diseases. Modulation of inflammasome-mediated inflammation may be a novel therapeutic strategy for cholesteatoma and chronic otitis media. NLRP3 inflammasome is a critical molecule mediating interleukin (IL)-1β responses. However, the expression of NLRP3 in the pathogenesis of cholesteatoma and chronic otitis media has not been fully examined. This study sought to assess the expression of NLRP3, ASC (apoptosis-associated speck-like protein containing a caspase recruitment domain and a pyrin domain), and caspase-1 in middle ear tissues in patients with cholesteatoma or chronic otitis media. Middle ear tissue samples were obtained from patients with cholesteatoma or chronic otitis media. Control middle ear samples were collected during cochlear implant surgery of patients without middle ear inflammation. The expression of NLRP3, ASC, and caspase-1 were examined by reverse transcription polymerase chain reaction (RT-PCR) assay and immunohistochemical study. The levels of mRNA of NLRP3, ASC, and caspase-1 were significantly elevated in cholesteatoma and chronic otitis media as compared with that of normal controls. The proteins of NLRP3, ASC, and caspase-1 were observed in infiltrating inflammatory cells in cholesteatoma and chronic otitis media.

  8. Structural Metadata Research in the Ears Program

    National Research Council Canada - National Science Library

    Liu, Yang; Shriberg, Elizabeth; Stolcke, Andreas; Peskin, Barbara; Ang, Jeremy; Hillard, Dustin; Ostendorf, Mari; Tomalin, Marcus; Woodland, Phil; Harper, Mary

    2005-01-01

    Both human and automatic processing of speech require recognition of more than just words. In this paper we provide a brief overview of research on structural metadata extraction in the DARPA EARS rich transcription program...

  9. Mozart ear: diagnosis, treatment, and literature review.

    Science.gov (United States)

    Yamashita, Ken; Yotsuyanagi, Takatoshi; Saito, Tamotsu; Isogai, Noritaka; Mori, Hiromasa; Itani, Yoshihito

    2011-11-01

    Mozart ear is a congenital auricular deformity, which is mainly characterized by a bulging appearance of the anterosuperior portion of the auricle, a convexly protruded cavum conchae, and a slit-like narrowing of the orifice of the external auditory meatus. It is said to be uncommon, and because no one has yet fully described neither the disease nor the treatment, the concept of Mozart ear has not been unified. This report describes a case of a 13-year-old girl presented with an unusual congenital deformity which showed the features of Mozart ear. It is an extremely rare deformity that only about 4 clinical cases have been reported in medical literature thereby a treatment method has not been fully discussed. For surgical correction of our cases, we excised deformed conchal cartilage, turned it over, regrafted, and maintained a cosmetically positive result. We also reviewed and described the origin, current concept, and treatment method of Mozart ear.

  10. Verrucous carcinoma of the middle ear.

    Science.gov (United States)

    Woodson, G E; Jurco, S; Alford, B R; McGavran, M H

    1981-01-01

    A case of a highly destructive, cytologically nondysplastic squamous epithelial lesion of the middle ear is presented. The cranial nerve involvement and bone destruction are more extensive than has been seen in cholesteatoma. Cultures are negative for Pseudomonas, and the patient does not have the reported diathesis for malignant otitis externa. The gross and microscopic features are those of verrucous carcinoma. To our knowledge, the middle ear has not been previously reported as a site of involvement by verrucous carcinoma.

  11. Osteoma of the middle ear: case report

    International Nuclear Information System (INIS)

    Ryu, Ji Hwa

    2005-01-01

    Osteomas of the middle ear are exceedingly rare benign neoplasms. To date, only 21 cases have been reported in the literature. They arise from the promontory, the pyramidal process and the ossicles, and they are usually asymptomatic or cause some conductive hearing loss. We report here the CT and pathologic findings in a 38-year-old woman with a benign osteoma of the middle ear along with chronic otitis media

  12. Commissioning of n_TOF EAR2

    CERN Multimedia

    The construction of the second beam line and experiment area (EAR2) of the n_TOF facility is currently ongoing and scheduled to be completed by July 2014. An extensive series of measurements is planned in order to determine the beam characteristics like the neutron flux, the spatial beam profile and the resolution function, as well as the response of several detectors considered for use in future measurements at EAR2. A rigorous study of backgrounds will be undertaken in various conditions.

  13. Osteoma of the middle ear: case report

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Ji Hwa [College of Medicine, Inje University, Dongrae Paik Hospital, Busan (Korea, Republic of)

    2005-07-15

    Osteomas of the middle ear are exceedingly rare benign neoplasms. To date, only 21 cases have been reported in the literature. They arise from the promontory, the pyramidal process and the ossicles, and they are usually asymptomatic or cause some conductive hearing loss. We report here the CT and pathologic findings in a 38-year-old woman with a benign osteoma of the middle ear along with chronic otitis media.

  14. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  15. 3D Rapid Prototyping for Otolaryngology—Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling

    Science.gov (United States)

    Chan, Harley H. L.; Siewerdsen, Jeffrey H.; Vescan, Allan; Daly, Michael J.; Prisman, Eitan; Irish, Jonathan C.

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques

  16. 3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

    Science.gov (United States)

    Chan, Harley H L; Siewerdsen, Jeffrey H; Vescan, Allan; Daly, Michael J; Prisman, Eitan; Irish, Jonathan C

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques

  17. 3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

    Directory of Open Access Journals (Sweden)

    Harley H L Chan

    Full Text Available The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i a mono-material paranasal sinus phantom for endoscopy training ii a multi-material skull base simulator and iii 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and

  18. Serous otitis media (S.O.M.). A bacteriological study of the ear canal and the middle ear

    NARCIS (Netherlands)

    Cabenda, S. I.; Peerbooms, P. G.; van Asselt, G. J.; Feenstra, L.; van der Baan, S.

    1988-01-01

    A bacteriological study of the middle-ear effusions and the ear canals in children with chronic serous otitis media (S.O.M.) was performed. Sixty-eight children (127 ears) were investigated. From this study it appeared that cleansing of the ear canal with 0.5% chlorhexidine in 70% ethanol for 30 s

  19. Ear-to-Ear On-Body Channel Fading in the ISM-band for Tangentially-Polarized Antennas

    DEFF Research Database (Denmark)

    Kvist, Søren Helstrup; Thaysen, Jesper; Jakobsen, Kaj Bjarne

    2011-01-01

    The ear-to-ear on-body channel fading has been studied in the ISM-band. The ear-to-ear path gain was measured on six persons in an indoor environment for a duration of 200 s. The channel fading has been characterized in terms of empirical cumulative distribution functions (CDF), average fade...

  20. Statistical Shape Analysis of the Human Ear Canal with Application to In-the-Ear Hearing Aid Design

    DEFF Research Database (Denmark)

    Paulsen, Rasmus Reinhold

    2004-01-01

    This thesis is about the statistical shape analysis of the human ear canal with application to the mechanical design of in-the-ear hearing aids. Initially, it is described how a statistical shape model of the human ear canal is built based on a training set of laser-scanned ear impressions. A thin...

  1. Air-Leak Effects on Ear-Canal Acoustic Absorbance

    Science.gov (United States)

    Rasetshwane, Daniel M.; Kopun, Judy G.; Gorga, Michael P.; Neely, Stephen T.

    2015-01-01

    Objective: Accurate ear-canal acoustic measurements, such as wideband acoustic admittance, absorbance, and otoacoustic emissions, require that the measurement probe be tightly sealed in the ear canal. Air leaks can compromise the validity of the measurements, interfere with calibrations, and increase variability. There are no established procedures for determining the presence of air leaks or criteria for what size leak would affect the accuracy of ear-canal acoustic measurements. The purpose of this study was to determine ways to quantify the effects of air leaks and to develop objective criteria to detect their presence. Design: Air leaks were simulated by modifying the foam tips that are used with the measurement probe through insertion of thin plastic tubing. To analyze the effect of air leaks, acoustic measurements were taken with both modified and unmodified foam tips in brass-tube cavities and human ear canals. Measurements were initially made in cavities to determine the range of critical leaks. Subsequently, data were collected in ears of 21 adults with normal hearing and normal middle-ear function. Four acoustic metrics were used for predicting the presence of air leaks and for quantifying these leaks: (1) low-frequency admittance phase (averaged over 0.1–0.2 kHz), (2) low-frequency absorbance, (3) the ratio of compliance volume to physical volume (CV/PV), and (4) the air-leak resonance frequency. The outcome variable in this analysis was the absorbance change (Δabsorbance), which was calculated in eight frequency bands. Results: The trends were similar for both the brass cavities and the ear canals. ΔAbsorbance generally increased with air-leak size and was largest for the lower frequency bands (0.1–0.2 and 0.2–0.5 kHz). Air-leak effects were observed in frequencies up to 10 kHz, but their effects above 1 kHz were unpredictable. These high-frequency air leaks were larger in brass cavities than in ear canals. Each of the four predictor variables

  2. Body lift, drag and power are relatively higher in large-eared than in small-eared bat species

    DEFF Research Database (Denmark)

    Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders

    2017-01-01

    Bats navigate the dark using echolocation. Echolocation is enhanced by external ears, but external ears increase the projected frontal area and reduce the streamlining of the animal. External ears are thus expected to compromise flight efficiency, but research suggests that very large ears may mi....... The result of this trade-off would be the eco-morphological correlation in bat flight, with large-eared bats generally adopting slow-flight feeding strategies....

  3. Investigate earing of TWIP steel sheet during deep-drawing process by using crystal plasticity constitutive model

    Directory of Open Access Journals (Sweden)

    Yang J.

    2015-01-01

    Full Text Available By combining the nonlinear finite element analysis techniques and crystal plasticity theory, the macroscopic mechanical behaviour of crystalline material, the texture evolution and earing-type characteristics are simulated accurately. In this work, a crystal plasticity model exhibiting deformation twinning is introduced based on crystal plasticity theory and saturation-type hardening laws for FCC metal Fe-22Mn-0.6C TWIP steel. Based on the CPFE model and parameters which have been determined for TWIP steel, a simplified finite element model for deep drawing is promoted by using crystal plasticity constitutive model. The earing characteristics in typical deep-drawing process are simulated well. Further, the drawing forces are calculated and compared to the experimental results from reference. Meanwhile, the impacts of drawing coefficient and initial texture on the earing characteristics are investigated for controlling the earing.

  4. Structure and function of the mammalian middle ear. I: Large middle ears in small desert mammals.

    Science.gov (United States)

    Mason, Matthew J

    2016-02-01

    Many species of small desert mammals are known to have expanded auditory bullae. The ears of gerbils and heteromyids have been well described, but much less is known about the middle ear anatomy of other desert mammals. In this study, the middle ears of three gerbils (Meriones, Desmodillus and Gerbillurus), two jerboas (Jaculus) and two sengis (elephant-shrews: Macroscelides and Elephantulus) were examined and compared, using micro-computed tomography and light microscopy. Middle ear cavity expansion has occurred in members of all three groups, apparently in association with an essentially 'freely mobile' ossicular morphology and the development of bony tubes for the middle ear arteries. Cavity expansion can occur in different ways, resulting in different subcavity patterns even between different species of gerbils. Having enlarged middle ear cavities aids low-frequency audition, and several adaptive advantages of low-frequency hearing to small desert mammals have been proposed. However, while Macroscelides was found here to have middle ear cavities so large that together they exceed brain volume, the bullae of Elephantulus are considerably smaller. Why middle ear cavities are enlarged in some desert species but not others remains unclear, but it may relate to microhabitat. © 2015 Anatomical Society.

  5. Prenatal evaluation of the middle ear and diagnosis of middle ear hypoplasia using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Katorza, Eldad; Nahama-Allouche, Catherine; Ducou le Pointe, Hubert; Garel, Catherine [Hopital d' Enfants Armand-Trousseau, Service de Radiologie, Paris (France); Castaigne, Vanina [Hopital Saint-Antoine, Service de Gynecologie-Obstetrique, Paris (France); Gonzales, Marie; Marlin, Sandrine [Hopital d' Enfants Armand-Trousseau, Service de Genetique et Embryologie medicales, Paris (France); Galliani, Eva [Hopital d' Enfants Armand-Trousseau, Service de Chirurgie maxillo-faciale, Paris (France); Jouannic, Jean-Marie; Rosenblatt, Jonathan [Hopital d' Enfants Armand-Trousseau, Service de Gynecologie-Obstetrique, Centre pluridisciplinaire de diagnostic prenatal, Paris (France)

    2011-05-15

    Analysis of the middle ear with fetal MRI has not been previously reported. To show the contribution of fetal MRI to middle ear imaging. The tympanic cavity was evaluated in 108 fetal cerebral MRI examinations (facial and/or cerebral malformation excluded) and in two cases, one of Treacher Collins syndrome (case 1) and the other of oculo-auriculo-vertebral (OUV) spectrum (case 2) with middle ear hypoplasia identified by MRI at 27 and 36 weeks' gestation, respectively. In all 108 fetuses (mean gestational age 32.5 weeks), the tympanic cavity and T2 hypointensity related to the ossicles were well visualised on both sides. Case 1 had micro/retrognathia and bilateral external ear deformity and case 2 had retrognathism with a left low-set and deformed ear. MRI made it possible to recognize the marked hypoplasia of the tympanic cavity, which was bilateral in case 1 and unilateral in case 2. Both syndromes are characterized by craniofacial abnormalities including middle ear hypoplasia, which cannot be diagnosed with US. The middle ear cavity can be visualized with fetal MRI. We emphasize the use of this imaging modality in the diagnosis of middle ear hypoplasia. (orig.)

  6. Algorithm for planning a double-jaw orthognathic surgery using a computer-aided surgical simulation (CASS) protocol. Part 1: planning sequence

    Science.gov (United States)

    Xia, J. J.; Gateno, J.; Teichgraeber, J. F.; Yuan, P.; Chen, K.-C.; Li, J.; Zhang, X.; Tang, Z.; Alfi, D. M.

    2015-01-01

    The success of craniomaxillofacial (CMF) surgery depends not only on the surgical techniques, but also on an accurate surgical plan. The adoption of computer-aided surgical simulation (CASS) has created a paradigm shift in surgical planning. However, planning an orthognathic operation using CASS differs fundamentally from planning using traditional methods. With this in mind, the Surgical Planning Laboratory of Houston Methodist Research Institute has developed a CASS protocol designed specifically for orthognathic surgery. The purpose of this article is to present an algorithm using virtual tools for planning a double-jaw orthognathic operation. This paper will serve as an operation manual for surgeons wanting to incorporate CASS into their clinical practice. PMID:26573562

  7. Ear, nose, and throat disorders in a nigerian rural community

    Directory of Open Access Journals (Sweden)

    Waheed Atilade Adegbiji

    2017-01-01

    Full Text Available Aims and Objectives: This study aimed at assessing the prevalence of ear, nose, and throat with head and neck diseases in a rural community in Oyo State, Nigeria. Materials and Methods: This is a prospective community-based study of ear, nose, and throat diseases. The study was carried out over a period of 3 months (January to March 2017. Verbal consent was obtained from the village head and participants. A total of 738 individuals were enrolled into the study. Interview-assisted questionnaire was administered to obtain bio data and otorhinolaryngological history from all participants, followed by examination and investigation. Data obtained were collated and statistically analyzed using SPSS version 16. Results: A total of 738 consented participants had various forms of ear, nose, and throat disorders. They constituted 435 (58.9% males and 303 (41.1% females, with a male: female ratio of 1:1. Majority of enrollee were dependent age groups. These age groups were 27.4% (1–10, 25.5% (11–20, and 14.1% (51–60. The occupational status revealed that 28.9% were employed; 9.3% were retired; 45.5% were children/students/apprenticeship; and 16.3% were artisans, homemakers, and farmers. Nasal diseases (34.4% were the most common otorhinolaryngological, head and neck disorders while ear, nose, and throat with head and neck diseases were responsible for 43.4%, 14.6%, and 7.6%, respectively. The common diseases were wax impaction (11.7%, sinusitis (14.4%, and allergic rhinitis (22.6%. Less prevalent otorhinolaryngological, head and neck diseases were vertigo/balance disorder (0.9%, cervical spondylosis (1.6%, and pharyngitis/tonsillitis (2.0%. Common procedures performed included impacted earwax removal (22.8%, aural toilet/dressing (14.4%, pure tone audiometry (32.5%, tympanometry (18.4%, endoscopy (9.8%, and antral irrigation (5.7%. Referred cases of 7.2% were recorded. The barriers experienced by these villagers in seeking otorhinolaryngological

  8. Gait asymmetry detection in older adults using a light ear-worn sensor

    International Nuclear Information System (INIS)

    Atallah, L; Lo, B; Yang, G-Z; Wiik, A; Cobb, J P; Amis, A A

    2014-01-01

    Measuring gait asymmetry is an important feature when characterizing functional imbalance between limbs. This could be due to pathologies, such as osteoarthritis, stroke, or associated with the effects of surgeries such as hip arthroplasty. Generally, the study of asymmetry or imbalance has required the use of a gait lab or force plates, which could be expensive and difficult to use in home settings. This work validates the use of a light weight ear sensor (7.4 g) with an instrumented treadmill for 64 subjects (age (60.04 (15.36)) including healthy subjects (14) as well as subjects who had been treated for hip (17), knee-replacement surgery (21) and knee osteoarthritis (12). Subjects performed treadmill walking at several speeds on flat surfaces, inclines and declines. Accelerometer data from the ear sensor were segmented into consecutive steps and temporal features were extracted. The measures of gait cycle time and step-period asymmetry obtained from the ear sensor matched well those of the treadmill for flat surfaces, inclines and declines. The key implication of the study is that the proposed method could replace expensive equipment for monitoring temporal gait features in clinics as well as free-living environments, which is important for monitoring rehabilitation after surgery and the progress of diseases affecting limb imbalance. (note)

  9. CT of temporal bone - IV. inner ear

    International Nuclear Information System (INIS)

    Kwon, Jae Yoon; Sung, Kyu Bo; Youn, Eun Kyoung; Park, Youn Kyeung; Lee, Young Uk

    1990-01-01

    Temporal bone CT was done in 697 patients from April 1985 to October 1989. The abnormal findings were seen in 453 patients, which were chronic otitis media in 355 patients, fracture in 49 patients and congenital anomaly in 44 patients, etc. The abnormal findings of inner ear were observed on 46 patients. The results were summarized as follows : 1. The incidence of inner ear involvement by chronic otitis media was 7.3% (26/355 : labyrinthine fistula in 17 patients, labyrinthitis ossificans in 9 patients). Labyrinthine fistula was most commonly located on lateral semicircular canal (15/17, 88.2%). 2. Fusion of vestibule with lateral semicircular canal and formation of common cavity was demonstrated incidentally in 5 patients (0.7% of total number of temporal bone CT), and bilateral in 3 patients. 3. The incidence of inner ear anomaly in congenital ear anomaly was 11.4% (5/44). All cases were bilateral and three patients showed associated middle ear anomaly. 4. The incidence of involvement of bony labyrinth in temporal bone fracture was 10.2% (5/49). Labyrinthine fracture was seen all patients of transverse(3) and mixed fracture(1). In longitudinal fracture, labyrinthine fracture was seen in 2.2% (1/45). 5. Others were traumatic labyrinthitis ossificans(1), intracanalicular acoustic neuroma(3) and facial nerve neuroma(1)

  10. Evolution and development of the vertebrate ear

    Science.gov (United States)

    Fritzsch, B.; Beisel, K. W.

    2001-01-01

    This review outlines major aspects of development and evolution of the ear, specifically addressing issues of cell fate commitment and the emerging molecular governance of these decisions. Available data support the notion of homology of subsets of mechanosensors across phyla (proprioreceptive mechanosensory neurons in insects, hair cells in vertebrates). It is argued that this conservation is primarily related to the specific transducing environment needed to achieve mechanosensation. Achieving this requires highly conserved transcription factors that regulate the expression of the relevant structural genes for mechanosensory transduction. While conserved at the level of some cell fate assignment genes (atonal and its mammalian homologue), the ear has also radically reorganized its development by implementing genes used for cell fate assignment in other parts of the developing nervous systems (e.g., neurogenin 1) and by evolving novel sets of genes specifically associated with the novel formation of sensory neurons that contact hair cells (neurotrophins and their receptors). Numerous genes have been identified that regulate morphogenesis, but there is only one common feature that emerges at the moment: the ear appears to have co-opted genes from a large variety of other parts of the developing body (forebrain, limbs, kidneys) and establishes, in combination with existing transcription factors, an environment in which those genes govern novel, ear-related morphogenetic aspects. The ear thus represents a unique mix of highly conserved developmental elements combined with co-opted and newly evolved developmental elements.

  11. Ear Acupuncture in European Traditional Medicine

    Directory of Open Access Journals (Sweden)

    Luigi Gori

    2007-01-01

    Full Text Available Auricular acupuncture is a diagnostic and treatment system based on normalizing the body's dysfunction through stimulation of definite points on the ear. Rudimentary forms of acupuncture which probably arose during the Stone Age have survived in many parts of the world right down to present day. It was used in the ancient Egypt, Rome, Greece and all the Mediterranean area. It is a microacupuncture technique similar to reflexology, and was first described in France in 1950 by Paul Nogier who is considered the Father of modern ear acupuncture. It was speculated that the technique works because groups of pluripotent cells contain information from the whole organism and create regional organization centers representing different parts of the body. Nevertheless stimulation of a reflex point in the ear seems relieve symptoms of distant pathologies. Modern research is confirming the efficacy of ear acupuncture for analgesia and anxiety related disease, while tobacco dependence and other substance abuse still need confirmation. Actually main methodological problems with auricular acupuncture are that exist too many maps with little agreement regarding point location in the ear, and that the correspondence or reflex systems does not correlated with modern knowledge of anatomy and physiology.

  12. Carcinoma of the external auditory canal and middle ear

    International Nuclear Information System (INIS)

    Pfreundner, Leo; Schwager, Konrad; Willner, Jochen; Baier, Kurt; Bratengeier, Klaus; Brunner, Franz Xaver; Flentje, Michael

    1999-01-01

    Purpose: To evaluate therapeutic modalities used at our institutions regarding local control, disease-free survival and actuarial survival in carcinoma of the external auditory canal and middle ear, in an attempt to provide guidelines for therapy. Methods and Materials: A series of 27 patients with carcinoma of the external auditory canal and middle ear treated between 1978 and 1997 in our institutions were analyzed with particular reference to tumor size and its relation to surrounding tissues, patterns of neck node involvement, surgical procedures, and radiation techniques employed. Clinical endpoints were freedom from local failure, overall survival, and disease-free survival. The median follow-up was 2.7 years (range 0.1-17.9 years). Results: Treatment by surgery and radiotherapy resulted in an overall 5-year survival rate of 61%. According to the Pittsburgh classification, the actuarial 5-year survival rate for early disease (T1 and T2 tumors) was 86%, for T3 tumors 50%, and T4 stages 41%. Patients with tumors limited to the external auditory canal had a 5-year survival rate of 100%, patients with tumor invasion of the temporal bone 63%, and patients with tumor infiltration beyond the temporal bone 38%. The rate of freedom from local recurrence was 50% at 5 years. Unresectability by dural and cerebral infiltration, and treatment factors such as complete resection or resection with tumor beyond surgical margins are of prognostic relevance. All patients with dural invasion died within 2.2 years. The actuarial 5-year survival rate of patients with complete tumor resection was 100%, but 66% in patients with tumor beyond surgical margins. 192 Iridium high-dose-rate (HDR) afterloading brachytherapy based on three-dimensional computed tomography (3D CT)-treatment planning was an effective tool in management of local recurrences following surgery and a full course of external beam radiotherapy. Conclusion: Surgical resection followed by radiotherapy adapted to stage

  13. Basic Microvascular Anastomosis Simulation Hub Microsurgery Course: An Innovative Competency-Based Approach to Microsurgical Training for Early Year's Plastic Surgery Trainees.

    Science.gov (United States)

    Ali, Stephen

    2018-04-01

    Early year's plastic surgery trainees are faced with a large choice of microsurgery courses to select from. In the context of dwindling study budgets and busy on-call rotas, the pressure to select a high yield course that delivers value for money is of paramount importance.The Basic Microvascular Anastomosis Simulation Hub Microsurgery Course is a GBP £600 (US $790) 5-day 40-hour course based at Barts and The London School of Medicine and Dentistry increasing in popularity among junior trainees to fit this brief.

  14. Are two ears not better than one?

    Science.gov (United States)

    McArdle, Rachel A; Killion, Mead; Mennite, Monica A; Chisolm, Theresa H

    2012-03-01

    The decision to fit one or two hearing aids in individuals with binaural hearing loss has been debated for years. Although some 78% of U.S. hearing aid fittings are binaural (Kochkin , 2010), Walden and Walden (2005) presented data showing that 82% (23 of 28 patients) of their sample obtained significantly better speech recognition in noise scores when wearing one hearing aid as opposed to two. To conduct two new experiments to fuel the monaural/binaural debate. The first experiment was a replication of Walden and Walden (2005), whereas the second experiment examined the use of binaural cues to improve speech recognition in noise. A repeated measures experimental design. Twenty veterans (aged 59-85 yr), with mild to moderately severe binaurally symmetrical hearing loss who wore binaural hearing aids were recruited from the Audiology Department at the Bay Pines VA Healthcare System. Experiment 1 followed the procedures of the Walden and Walden study, where signal-to-noise ratio (SNR) loss was measured using the Quick Speech-in-Noise (QuickSIN) test on participants who were aided with their current hearing aids. Signal and noise were presented in the sound booth at 0° azimuth under five test conditions: (1) right ear aided, (2) left ear aided, (3) both ears aided, (4) right ear aided, left ear plugged, and (5) unaided. The opposite ear in (1) and (2) was left open. In Experiment 2, binaural Knowles Electronics Manikin for Acoustic Research (KEMAR) manikin recordings made in Lou Malnati's pizza restaurant during a busy period provided a typical real-world noise, while prerecorded target sentences were presented through a small loudspeaker located in front of the KEMAR manikin. Subjects listened to the resulting binaural recordings through insert earphones under the following four conditions: (1) binaural, (2) diotic, (3) monaural left, and (4) monaural right. Results of repeated measures ANOVAs demonstrated that the best speech recognition in noise performance was

  15. MRI measurement for inner ear structures

    International Nuclear Information System (INIS)

    Li Shuling; Liu Huaijun; Chi Chen; Qin Ruiping; Shi Zhaoxia

    2003-01-01

    Objective: To reconstruct the image of inner ear by using 3D-FASE heavily T 2 WI, and to establish MRI measurement criterion of inner ear structures. Methods: One hundred and six inner ears of 53 healthy volunteers underwent MRI heavily T2-weighted axial scanning by using 3D fast advanced spin echo sequence. All the original images were transferred to an online workstation. Analyze AVW software was used for image post-processing. All the structures of inner ear were reconstructed, rotated from various angles and measured by using maximum intensity projection (MIP). Results: (1) All the structures of inner ear and internal auditory channel (IAC) could be visualized clearly by using 3D-FASE heavily T 2 WI. (2) Using analysis of variance, there was no age, side or race-related difference in inner ear volume, but it was bigger in male than in female [(0.242 ± 0.0236) mm 3 (male) versus (0.226 ± 0.021) mm 3 (female)]. There was no age, side-related differences in three semicircular canal height and vestibule vertical diameter, but, again, they were bigger in male than in female. The height of upper, lateral and posterior semicircular canal were (5.511 ± 0.626) mm (male) versus (5.167 ± 0.357) mm (female); (3.763 ± 0.495) mm (male) versus (3.446 ± 0.405) mm (female); (5.227 ± 0.547) mm (male) versus (4.786 ± 0.500) mm (female). There was no age, sex or side-related differences in three semicircular canal diameter and cochlea. The diameter of upper, lateral and posterior semicircular canal were (1.06 ± 0.119) mm, (1.14 ± 0.181) mm, and (1.22 ± 0.196)mm; the external diameter of cochlea basal turn was (6.520 ± 0.475) mm, the diameter of cochlea basal turn was (1.413 ± 0.144) mm, and cochlea height was (4.100 ± 0.405) mm. Conclusion: (1) For the first time, the MRI measurement criterion of inner ear structures is established. (2) Vestibule and three semicircular canal of inner ear are bigger in male than in female

  16. Multislice spiral computed tomography imaging in congenital inner ear malformations.

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Tian, Zhi-liang; Lei, Zi-qiao; Kong, Wei-jia; Feng, Gan-sheng

    2008-01-01

    The purpose of this study is to evaluate the usefulness of multislice spiral computed tomography (CT) in the diagnosis of congenital inner ear malformations. Forty-four patients with sensorineural hearing loss were examined on a Somatom Sensation 16 (Siemens) CT scanner. The 3-dimensional reconstructions and multiplanar reformation (MPR) were performed using the volume-rendering technique (VRT) on the workstation. Of the 44 patients examined for this study, 25 patients were found to be normal and 19 patients (36 ears) were diagnosed with congenital inner ear malformations. Of the malformations, the axial, MPR, and VRT images can all display the site and degree in 33 of the ears. Volume-rendering technique images were superior to the axial images in displaying the malformations in 3 ears with small lateral semicircular canal malformations. The common malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity) (5 ears), vestibular and semicircular canal malformations (14 ears), enlarged vestibular aqueduct (16 ears, 6 of which had other malformations), and internal auditory canal malformation (8 ears, all accompanied by other malformations). Multislice spiral CT allows a comprehensively assessment of various congenital inner ear malformations through high-quality MPR and VRT reconstructions. Volume-rendering technique images can display the site and degree of the malformation 3-dimensionally and intuitionisticly. This is very useful to the cochlear implantation.

  17. Geometric and mechanical evaluation of 3D-printing materials for skull base anatomical education and endoscopic surgery simulation – A first step to create reliable customized simulators

    OpenAIRE

    Favier, Valentin; Zemiti, Nabil; Caravaca Mora, Oscar; Subsol, Gérard; Captier, Guillaume; Lebrun, Renaud; Crampette, Louis; Mondain, Michel; Gilles, Benjamin

    2017-01-01

    Introduction Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. Methods Four 3D-printed consumer-grade materials were...

  18. Factors contributing to hearing impairment in patients with cleft lip/palate in Malaysia: A prospective study of 346 ears.

    Science.gov (United States)

    Cheong, Jack Pein; Soo, Siew Shuin; Manuel, Anura Michelle

    2016-09-01

    To determine the factors contributing towards hearing impairment in patients with cleft lip/palate. A prospective analysis was conducted on 173 patients (346 ears) with cleft lip and palate (CL/P) who presented to the combined cleft clinic at University Malaya Medical Centre (UMMC) over 12 months. The patients' hearing status was determined using otoacoustic emission (OAE), pure tone audiometry (PTA) and auditory brainstem response (ABR). These results were analysed against several parameters, which included age, gender, race, types of cleft pathology, impact and timing of repair surgery. The patients' age ranged from 1-26 years old. They comprised 30% with unilateral cleft lip and palate (UCLP), 28% with bilateral cleft lip and palate (BCLP), 28% with isolated cleft palate (ICP) and 14% with isolated cleft lip (ICL). Majority of the patients (68.2%) had normal otoscopic findings. Out of the 346 ears, 241 ears (70%) ears had passed the hearing tests. There was no significant relationship between patients' gender and ethnicity with their hearing status. The types of cleft pathology significantly influenced the outcome of PTA and ABR screening results (p cleft groups and the outcome of hearing tests. However, hearing improvement occurred when palatal repair was performed at the age of cleft patients had normal hearing (70%). Hearing threshold varied significantly between the different types of cleft pathology. Surgery conferred no significant impact on the hearing outcome unless surgery was performed at the age of <1 year old. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Performance and ergonomic characteristics of expert surgeons using a face-mounted display during virtual reality-simulated laparoscopic surgery: an electromyographically based study.

    Science.gov (United States)

    Lin, D W; Bush, R W; Earle, D B; Seymour, N E

    2007-07-01

    Display positions for laparoscopy in current operating rooms may not be optimal for surgeon comfort or task performance, and face-mounted displays (FMDs) have been forwarded as a potential ergonomic solution. Little is known concerning expert use characteristics of these devices that might help define their role in future surgical care. The authors report the performance and ergonomic characterization of an FMD using virtual reality simulation technology to recreate the surgical environment. An FMD was studied in short- and long-duration trials of validated virtual reality-simulated surgical tasks. For the short-duration phase 7, expert surgeons were familiarized with a task on a conventional monitor, then returned on two separate occasions to repeat the task with the FMD while digital photos were taken during task performance and at the end in a standardized fashion. For the long-duration phase 5, expert surgeons performed two separate trials with repetitive groups of validated tasks for a minimum of 30 min while electromyelogram and performance data were measured. Photos of their gaze angle during and at the end of the trial were taken. All the participants consistently assumed a gaze angle slightly below horizontal during task performance. Performance scores on the FMD did not differ from those obtained with a conventional display, and remained stable with repetitive task performance. No participant had electromyelogram signals that exceeded the established thresholds for fatigue, but some had values within the threshold range. The natural gaze angle during simulated surgery was consistently a bit below horizontal during rigorous virtual reality-simulated tasks. Performance was not compromised during expert surgeons' use of an FMD, nor did muscle fatigue characteristics arise under these conditions. The findings suggest that these devices may represent a viable alternative to conventional displays for minimally invasive surgery, but definition of specific roles

  20. Cauliflower ear – a minimally invasive treatment method in a wrestling athlete: a case report

    Directory of Open Access Journals (Sweden)

    Haik J

    2018-01-01

    Full Text Available Josef Haik,1–4 Or Givol,2 Rachel Kornhaber,1,5 Michelle Cleary,6 Hagit Ofir,1,2 Moti Harats1–3 1Department of Plastic and Reconstructive Surgery, Sheba Medical Center, Tel Hashomer, Ramat Gan, 2Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel; 3Burn Injury Research Node, Institute for Health Research University of Notre Dame Fremantle, Fremantle WA, Australia; 4Talpiot Leadership Program, Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel; 5Faculty of Health, 6School of Health Sciences, College of Health and Medicine, University of Tasmania, Sydney, NSW, Australia Abstract: Acute auricular hematoma can be caused by direct blunt trauma or other injury to the external ear. It is typically seen in those who practice full contact sports such as boxing, wrestling, and rugby. “Cauliflower ear” deformity, fibrocartilage formation during scarring, is a common complication of auricular hematomas. Therefore, acute drainage of the hematoma and postprocedural techniques for preventing recurrence are necessary for preventing the deformity. There are many techniques although no superior method of treatment has been found. In this case report, we describe a novel method using needle aspiration followed by the application of a magnet and an adapted disc to the affected area of the auricular. This minimally invasive, simple, and accessible method could potentially facilitate the treatment of cauliflower ear among full contact sports athletes. Keywords: cauliflower ear, hematoma, ear deformity, athletic injuries, wrestling, case report

  1. Pediatric Obesity and Ear, Nose, and Throat Disorders

    Science.gov (United States)

    ... Marketplace Find an ENT Doctor Near You Pediatric Obesity and Ear, Nose, and Throat Disorders Pediatric Obesity ... self-esteem, and isolation from their peers. Pediatric obesity and otolaryngic problems Otolaryngologists, or ear, nose, and ...

  2. Middle Ear Infection (Chronic Otitis Media) and Hearing Loss

    Science.gov (United States)

    ... Marketplace Find an ENT Doctor Near You Middle Ear Infection (Chronic Otitis Media) and Hearing Loss Middle Ear Infection (Chronic Otitis ... relations staff at newsroom@entnet.org . What is otitis media? Otitis media refers to inflammation of the middle ...

  3. Sub-clinical middle ear malfunctions in elderly patients; prevalence ...

    African Journals Online (AJOL)

    ... absent acoustic reflex. Keywords: Middle ear malfunctions, elderly patients. ... hearing loss, had audiometric changes suggestive of such. We regarded such .... predictors of silent middle ear malfunction (control for Age and Sex). Variable.

  4. Pediatric Obesity and Ear, Nose, and Throat Disorders

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Pediatric Obesity and Ear, Nose, and Throat Disorders Pediatric ... of self-esteem, and isolation from their peers. Pediatric obesity and otolaryngic problems Otolaryngologists, or ear, nose, ...

  5. Middle Ear Infection (Chronic Otitis Media) and Hearing Loss

    Science.gov (United States)

    ... ENT Doctor Near You Middle Ear Infection (Chronic Otitis Media) and Hearing Loss Middle Ear Infection (Chronic ... relations staff at newsroom@entnet.org . What is otitis media? Otitis media refers to inflammation of the ...

  6. Body lift, drag and power are relatively higher in large-eared than in small-eared bat species.

    Science.gov (United States)

    Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders; Johansson, L Christoffer

    2017-10-01

    Bats navigate the dark using echolocation. Echolocation is enhanced by external ears, but external ears increase the projected frontal area and reduce the streamlining of the animal. External ears are thus expected to compromise flight efficiency, but research suggests that very large ears may mitigate the cost by producing aerodynamic lift. Here we compare quantitative aerodynamic measures of flight efficiency of two bat species, one large-eared ( Plecotus auritus ) and one small-eared ( Glossophaga soricina ), flying freely in a wind tunnel. We find that the body drag of both species is higher than previously assumed and that the large-eared species has a higher body drag coefficient, but also produces relatively more ear/body lift than the small-eared species, in line with prior studies on model bats. The measured aerodynamic power of P. auritus was higher than predicted from the aerodynamic model, while the small-eared species aligned with predictions. The relatively higher power of the large-eared species results in lower optimal flight speeds and our findings support the notion of a trade-off between the acoustic benefits of large external ears and aerodynamic performance. The result of this trade-off would be the eco-morphological correlation in bat flight, with large-eared bats generally adopting slow-flight feeding strategies. © 2017 The Author(s).

  7. Headaches from ear, nose and throat diseases

    International Nuclear Information System (INIS)

    Reck, R.

    1984-01-01

    Headaches are a frequent symptom in ENT-patients. The complex sensory innervation of the ear, nose and paranasal sinuses is demonstrated. Heterotopic or referred pain must be differentiated from homotopic pain that is experienced at the point of injury. The nervous pathways of heterotopic otalgia are shown. The quality of pain of the most common rhinological and otological diseases is reported. (orig.) [de

  8. DNA isolation from rat tail or ear

    NARCIS (Netherlands)

    Cuppen, E.

    2010-01-01

    This protocol describes a rapid procedure for isolating DNA from rat tail or ear punches. The simplest version of the protocol can be scaled for use in 96-well (deep-well) plates. The quality of the DNA is sufficient for any polymerase chain reaction (PCR)-based genotyping approach.

  9. The first neutron beam hits EAR2

    CERN Multimedia

    Antonella Del Rosso

    2014-01-01

    On 25 July 2014, about a year after construction work began, the Experimental Area 2 (EAR2) of CERN’s neutron facility n_TOF recorded its first beam. Unique in many aspects, EAR2 will start its rich programme of experimental physics this autumn.   The last part of the EAR2 beamline: the neutrons come from the underground target and reach the top of the beamline, where they hit the samples. Built about 20 metres above the neutron production target, EAR2 is in fact a bunker connected to the n_TOF underground facilities via a duct 80 cm in diameter, where the beamline is installed. The feet of the bunker support pillars are located on the concrete structure of the n_TOF tunnel and part of the structure lies above the old ISR building. A beam dump located on the roof of the building completes the structure. Neutrons are used by physicists to study neutron-induced reactions with applications in a number of fields, including nuclear waste transmutation, nuclear technology, nuclear astrop...

  10. "Hot Tub Rash" and "Swimmer's Ear" (Pseudomonas)

    Science.gov (United States)

    Facts About “Hot Tub Rash” and “Swimmer’s Ear” (Pseudomonas) What is Pseudomonas and how can it affect me? Pseudomonas (sue-doh- ... a major cause of infections commonly known as “hot tub rash” and “swimmer’s ear.” This germ is ...

  11. Clinical review of inner ear malformation

    International Nuclear Information System (INIS)

    Kokai, Hiromi; Oohashi, Masami; Ishikawa, Kazuo; Harada, Kouji; Hiratsuka, Hitoshi; Ogasawara, Makoto; Miyashita, Souji; Terayama, Yoshihiko

    2003-01-01

    We had 126 patients with inner ear malformation diagnosed with temporal bone computed tomography (CT) scans at Azabu Triology Hospital between 1996 and 2002. We classified cases of inner ear malformation according to Jackler et al. The incidence of inner ear malformation in our series was as follows; labyrinthine anomalies 61% (isolated lateral semicircular canal dysplasia 56%, compound semicircular canal dysplasia 4%, semicircular canal aplasia 1%), cochlear anomalies 24%, enlargement of the vestibular aqueduct 12%, narrow internal auditory canal 2%, complete labyrinthine aplasia 1%, enlargement of the cochlear aqueduct 0%. The most frequent anomaly was isolated lateral semicircular canal dysplasia. We did not detect any significant clinical features in this anomaly. There were 2 patients with cochlear anomalies who had past histories of meningitis. Some patients with enlargement of the vestibular aqueduct had frequent attacks of fluctuating hearing. Clinically it is important to detect patients with inner ear malformation such as cochlear anomalies and enlargement of the vestibular aqueduct usually accompanied by congenital sensorineural hearing loss. For patients with congenital sensorineural hearing loss, we recommend temporal bone CT scan. (author)

  12. Cholesteatoma of the external ear canal

    DEFF Research Database (Denmark)

    Owen, Hanne H; Rosborg, Jørn; Gaihede, Michael

    2006-01-01

    (n = 2), and otorrhea (n = 1). Similar symptoms were found in secondary EECC, but less pronounced. In total the temporomandibular joint was exposed in 11 cases, while the mastoid and middle ear was invaded in six and three cases, respectively. In one primary case the facial nerve was exposed...

  13. The inner ear produces a natriuretic hormone

    DEFF Research Database (Denmark)

    Qvortrup, K; Rostgaard, J; Holstein-Rathlou, N H

    1996-01-01

    Cytoplasmic granules have been demonstrated in epithelial cells from the endolymphatic sac, an extraosseus part of the inner ear located in the posterior cranial fossa. Intravenously infused extracts from endolymphatic sacs in anesthetized rats elicited a potent natriuresis and diuresis without e...

  14. Learning in a Simulation-OT in Heart Surgery and the Challenges of the Scientification of Work

    Science.gov (United States)

    Langemeyer, Ines

    2014-01-01

    Enhancing competency and collaboration has become a salient topic of the professional debate on medical safety issues. The advantages of simulation-based training scenarios for team communication, routines and critical work procedures especially in operation theatres have been vigorously discussed. However, the literature on simulation-based…

  15. Computer-Assisted Orthognathic Surgery for Patients with Cleft Lip/Palate: From Traditional Planning to Three-Dimensional Surgical Simulation

    Science.gov (United States)

    Lonic, Daniel; Pai, Betty Chien-Jung; Yamaguchi, Kazuaki; Chortrakarnkij, Peerasak; Lin, Hsiu-Hsia; Lo, Lun-Jou

    2016-01-01

    Background Although conventional two-dimensional (2D) methods for orthognathic surgery planning are still popular, the use of three-dimensional (3D) simulation is steadily increasing. In facial asymmetry cases such as in cleft lip/palate patients, the additional information can dramatically improve planning accuracy and outcome. The purpose of this study is to investigate which parameters are changed most frequently in transferring a traditional 2D plan to 3D simulation, and what planning parameters can be better adjusted by this method. Patients and Methods This prospective study enrolled 30 consecutive patients with cleft lip and/or cleft palate (mean age 18.6±2.9 years, range 15 to 32 years). All patients received two-jaw single-splint orthognathic surgery. 2D orthodontic surgery plans were transferred into a 3D setting. Severe bony collisions in the ramus area after 2D plan transfer were noted. The position of the maxillo-mandibular complex was evaluated and eventually adjusted. Position changes of roll, midline, pitch, yaw, genioplasty and their frequency within the patient group were recorded as an alternation of the initial 2D plan. Patients were divided in groups of no change from the original 2D plan and changes in one, two, three and four of the aforementioned parameters as well as subgroups of unilateral, bilateral cleft lip/palate and isolated cleft palate cases. Postoperative OQLQ scores were obtained for 20 patients who finished orthodontic treatment. Results 83.3% of 2D plans were modified, mostly concerning yaw (63.3%) and midline (36.7%) adjustments. Yaw adjustments had the highest mean values in total and in all subgroups. Severe bony collisions as a result of 2D planning were seen in 46.7% of patients. Possible asymmetry was regularly foreseen and corrected in the 3D simulation. Conclusion Based on our findings, 3D simulation renders important information for accurate planning in complex cleft lip/palate cases involving facial asymmetry that is

  16. Computer-Assisted Orthognathic Surgery for Patients with Cleft Lip/Palate: From Traditional Planning to Three-Dimensional Surgical Simulation.

    Directory of Open Access Journals (Sweden)

    Daniel Lonic

    Full Text Available Although conventional two-dimensional (2D methods for orthognathic surgery planning are still popular, the use of three-dimensional (3D simulation is steadily increasing. In facial asymmetry cases such as in cleft lip/palate patients, the additional information can dramatically improve planning accuracy and outcome. The purpose of this study is to investigate which parameters are changed most frequently in transferring a traditional 2D plan to 3D simulation, and what planning parameters can be better adjusted by this method.This prospective study enrolled 30 consecutive patients with cleft lip and/or cleft palate (mean age 18.6±2.9 years, range 15 to 32 years. All patients received two-jaw single-splint orthognathic surgery. 2D orthodontic surgery plans were transferred into a 3D setting. Severe bony collisions in the ramus area after 2D plan transfer were noted. The position of the maxillo-mandibular complex was evaluated and eventually adjusted. Position changes of roll, midline, pitch, yaw, genioplasty and their frequency within the patient group were recorded as an alternation of the initial 2D plan. Patients were divided in groups of no change from the original 2D plan and changes in one, two, three and four of the aforementioned parameters as well as subgroups of unilateral, bilateral cleft lip/palate and isolated cleft palate cases. Postoperative OQLQ scores were obtained for 20 patients who finished orthodontic treatment.83.3% of 2D plans were modified, mostly concerning yaw (63.3% and midline (36.7% adjustments. Yaw adjustments had the highest mean values in total and in all subgroups. Severe bony collisions as a result of 2D planning were seen in 46.7% of patients. Possible asymmetry was regularly foreseen and corrected in the 3D simulation.Based on our findings, 3D simulation renders important information for accurate planning in complex cleft lip/palate cases involving facial asymmetry that is regularly missed in conventional 2D

  17. Bacteriology of chronic discharging ears in Port Harcourt, Nigeria ...

    African Journals Online (AJOL)

    Methods: Ear swabs of discharging ears aseptically collected from 102 patients of various age groups attending Ear, Nose, and Throat out-patient clinic at University of Port Harcourt Teaching Hospital were cultured for bacterial agents using blood agar, chocolate agar and MacConkey agar. Culture plates were incubated ...

  18. Inner ear malformations in siblings presenting with vestibular ...

    African Journals Online (AJOL)

    Although the association between inner ear abnormalities and progressive sensorineural hearing loss is well known, vestibular signs or loss of vestibular function in these ... We provide a brief overview of the latest classification of these inner ear defects as well as a review of the literature pertaining to children with inner ear ...

  19. Influence of Ear Surface Area on Heat Tolerance of Composite ...

    African Journals Online (AJOL)

    Relative importance of ear surface area on heat tolerance of composite rabbit population was evaluated. The study was conducted during the dry and rainy seasons, climatic data were recorded to obtain categorical heat stress index. Physiological parameters, growth performance, ear length and ear width of the rabbits ...

  20. Role of skeletal muscle in ear development.

    Science.gov (United States)

    Rot, Irena; Baguma-Nibasheka, Mark; Costain, Willard J; Hong, Paul; Tafra, Robert; Mardesic-Brakus, Snjezana; Mrduljas-Djujic, Natasa; Saraga-Babic, Mirna; Kablar, Boris

    2017-10-01

    The current paper is a continuation of our work described in Rot and Kablar, 2010. Here, we show lists of 10 up- and 87 down-regulated genes obtained by a cDNA microarray analysis that compared developing Myf5-/-:Myod-/- (and Mrf4-/-) petrous part of the temporal bone, containing middle and inner ear, to the control, at embryonic day 18.5. Myf5-/-:Myod-/- fetuses entirely lack skeletal myoblasts and muscles. They are unable to move their head, which interferes with the perception of angular acceleration. Previously, we showed that the inner ear areas most affected in Myf5-/-:Myod-/- fetuses were the vestibular cristae ampullaris, sensitive to angular acceleration. Our finding that the type I hair cells were absent in the mutants' cristae was further used here to identify a profile of genes specific to the lacking cell type. Microarrays followed by a detailed consultation of web-accessible mouse databases allowed us to identify 6 candidate genes with a possible role in the development of the inner ear sensory organs: Actc1, Pgam2, Ldb3, Eno3, Hspb7 and Smpx. Additionally, we searched for human homologues of the candidate genes since a number of syndromes in humans have associated inner ear abnormalities. Mutations in one of our candidate genes, Smpx, have been reported as the cause of X-linked deafness in humans. Our current study suggests an epigenetic role that mechanical, and potentially other, stimuli originating from muscle, play in organogenesis, and offers an approach to finding novel genes responsible for altered inner ear phenotypes.

  1. Simulations

    CERN Document Server

    Ngada, Narcisse

    2015-06-15

    The complexity and cost of building and running high-power electrical systems make the use of simulations unavoidable. The simulations available today provide great understanding about how systems really operate. This paper helps the reader to gain an insight into simulation in the field of power converters for particle accelerators. Starting with the definition and basic principles of simulation, two simulation types, as well as their leading tools, are presented: analog and numerical simulations. Some practical applications of each simulation type are also considered. The final conclusion then summarizes the main important items to keep in mind before opting for a simulation tool or before performing a simulation.

  2. Inner ear pressure changes following square wave intracranial or ear canal pressure manipulation in the same guinea pig

    NARCIS (Netherlands)

    Thalen, E; Wit, H; Segenhout, H; Albers, F

    Inner ear pressure was measured in scala tympani with a micropipette during square wave pressure manipulation of the intracranial compartment and, subsequently, of the external ear canal (EEC) in the same guinea pig. As expected, the combination of the cochlear aqueduct and the inner ear behaves as

  3. Ear care: an update for nurses (part 1)

    OpenAIRE

    Millward, K.

    2017-01-01

    A healthy ear is vital not just for hearing, but for balance and for full engagement with the community. In the first of two articles, Kat Millward reviews the anatomy of the ear, outlines methods of dealing with cerumen, and discusses methods of assessment and diagnosis\\ud \\ud Our ears are essential for both hearing and balance. Up to 4% of the population will have difficulties with their ears relating to impacted cerumen and many of them will present in primary care with ear discomfort or h...

  4. Evaluation of CT-scanning of the temporal bone in the diagnosis of ear diseases

    International Nuclear Information System (INIS)

    Murata, Kiyotaka; Isono, Michio; Nishimae, Tadahide; Tamaki, Katsuhiko; Hosoi, Hiroshi; Ohta, Fumihiko

    1983-01-01

    CT-scanning of 96 temporal bones was carried out to reveal the extension of cholesteatoma, periossicular drainage, fracture lines, enlarged internal acoustic meatus and anomalies of labyrinthine capsules and ossicles. The clinical aspects of CT-scanning of the temporal bone (CTTB) were as follows: 1) Inner ear anomalies were observed in 17 temporal bones of unilateral deafness, high tone loss from unknown origin and fluctuant hearing loss. CTTB may explain the pathology of deafness from unknown origin. 2) Inner ear anomalies may be classified into more detailed groups than before. 3) The extension of cholesteatoma, localization and size of labyrinthine fistula can be estimated prior to surgery. 4) Cholesteatoma in a mastoidectomy cavity may be detected. 5) The malleus and incus may be visualized, although the stapes can hardly be found. 6) Fracture lines of a temporal bone, destruction of the internal acoustic meatus may be clearly detected. (author)

  5. Implementation of a novel portfolio of structured, curriculum-aligned, simulation-based, cardiothoracic surgery training courses: Evolving the delivery of surgical education.

    Science.gov (United States)

    Moorjani, Narain; Lewis, Michael; Shah, Rajesh; Barnard, Sion; Graham, Tim; Rathinam, Sridhar

    2017-12-01

    The provision of high-quality cardiothoracic surgical training faces many challenges. This has generated an increased interest in simulation-based learning, which can provide a less stressful environment for deliberate practice. We developed a comprehensive, structured program of knowledge and simulation-based learning aligned to the official cardiothoracic surgery curriculum. A portfolio of 10 curriculum-aligned training courses was designed for cardiothoracic surgical trainees during their 6-year training program. The courses were delivered through a multitude of education methods, including live porcine operating simulation models, and were evaluated through a series of quantitative (5-point Likert-scale) and qualitative assessments. The trainees (n = 15-21 per course) also completed pre- and postsession self-confidence and competency levels for each training episode of knowledge and skill, respectively. In addition, board examination pass rates were assessed in the 3-year periods before and after implementation of the courses. Quantitative analysis of the trainees' feedback demonstrated an extremely positive view of the portfolio of the simulation-based training courses with excellent satisfaction scores (out of 5) for teaching sessions (4.44 ± 0.07), faculty (4.64 ± 0.07), content and materials (4.63 ± 0.07), and facilities (4.73 ± 0.05). The courses have shown a significant improvement in the post-self-confidence (7.98 ± 0.13 vs 5.62 ± 0.20, P < .01) and perceived self-competency (8.10 ± 0.10 vs 5.67 ± 0.11, P < .01) scores for all courses. Examination pass rates significantly improved in the 3-year period after attendance at the courses (94.82% ± 2.34% vs 76.26% ± 3.23%, P < .005). This study has described the implementation of the only extensive program of structured simulation-based courses that has been developed to complement clinical training in cardiothoracic surgery. Crown Copyright © 2017. Published by Elsevier

  6. Endoscopic middle ear exploration in pediatric patients with conductive hearing loss.

    Science.gov (United States)

    Carter, John M; Hoff, Stephen R

    2017-05-01

    To describe our indications, findings, and outcomes for transcanal endoscopic middle ear exploration in pediatric patients with conductive hearing loss of unknown etiology, without effusions. Prospective case series for all pediatric patients undergoing totally endoscopic transcanal middle ear exploration between April 2012 and October 2015 at a pediatric tertiary care referral hospital. Demographic data, operative findings, and hearing results were reviewed. 21 cases were performed in 20 ears (1 revision). Average age at surgery was 7.98 years and average follow up was 2.1 years. Middle ear pathology identified on CT imaging was confirmed in 55% of cases while identified in 45% of cases where pre-operative imaging was non-diagnostic. 6/20 patients (30%) had an ossicular deformity. 8/20(40%) had bony ossicular fixation. 5/20(25%) had ossicular discontinuity. 2/20(10%) had facial nerve dehiscence impinging on the stapes. 15% had adhesive myringosclerosis or severe granulation causing hearing loss. Prosthetic ossiculoplasty was done in 7/21 (33.3%) of the cases, with 1 TORP, 3 PORPs, and 3 IS joint replacements. Imaging was predictive of intra-operative findings in 13/20 cases (55%). Trainees assisted in 16/21(76%) of cases. The average improvement of PTA was 11.65 dB (range -10 to 36.25), and the average ABG improved 10.19 (range -11.25 to 28.75). There were no perioperative complications or adverse events. The endoscopic transcanal approach for middle ear exploration offers excellent visualization and is one of the best applications for the endoscopes in pediatric otology cases. This is particularly helpful for "unexplained" conductive hearing loss where ossicular deformity/fixation/discontinuity is suspected. The etiology of the conductive hearing loss was definitively found in 100% of cases, and can be repaired in the same sitting when applicable. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Simulation of the impact of refractive surgery ablative laser pulses with a flying-spot laser beam on intrasurgery corneal temperature.

    Science.gov (United States)

    Shraiki, Mario; Arba-Mosquera, Samuel

    2011-06-01

    To evaluate ablation algorithms and temperature changes in laser refractive surgery. The model (virtual laser system [VLS]) simulates different physical effects of an entire surgical process, simulating the shot-by-shot ablation process based on a modeled beam profile. The model is comprehensive and directly considers applied correction; corneal geometry, including astigmatism; laser beam characteristics; and ablative spot properties. Pulse lists collected from actual treatments were used to simulate the temperature increase during the ablation process. Ablation efficiency reduction in the periphery resulted in a lower peripheral temperature increase. Steep corneas had lesser temperature increases than flat ones. The maximum rise in temperature depends on the spatial density of the ablation pulses. For the same number of ablative pulses, myopic corrections showed the highest temperature increase, followed by myopic astigmatism, mixed astigmatism, phototherapeutic keratectomy (PTK), hyperopic astigmatism, and hyperopic treatments. The proposed model can be used, at relatively low cost, for calibration, verification, and validation of the laser systems used for ablation processes and would directly improve the quality of the results.

  8. Current Status of Simulation in Otolaryngology: A Systematic Review.

    Science.gov (United States)

    Musbahi, Omar; Aydin, Abdullatif; Al Omran, Yasser; Skilbeck, Christopher James; Ahmed, Kamran

    Otolaryngology is a highly technical and demanding specialty and the requirements for surgical trainees to acquire proficiency remains challenging. Simulation has been purported to be an effective tool in assisting with this. The aim of this systematic review is to identify the available otolaryngology simulators, their status of validation, and evaluation the level of evidence behind each training model and thereby establish a level of recommendation. PubMed, ERIC, and Google Scholar databases were searched for articles that described otolaryngology simulators or training models between 1980 and April 2016. Any validation studies for simulators were also retrieved. Titles and abstracts were screened for relevance using the preferred reporting items for systematic reviews and meta-analysis (PRISMA) guidelines. Level of evidence (LoE) and Level of recommendation (LoR) was awarded to each study and model, respectively. A total of 70 studies were identified describing 64 simulators. Out of these, at least 54 simulators had 1 validation study. Simulators for the ear and temporal bone surgery were the most common (n = 32), followed by laryngeal and throat (n = 20) and endoscopic sinus surgery (n = 12). Face validity was evaluated by 29 studies, 20 attempted to show construct, 20 assessed content, 20 transfer, and only 2 assessed concurrent validity. Of the validation assessments, 2 were classified as Level 1b, 10 Level 2a, and 48 Level 2b. No simulators received the highest LoR, but 8 simulators received a LoR of 2. Despite the lack of evidence in outcome studies and limited number of high-validity otolaryngology simulators, the role of simulation continues to grow across surgical specialties Hence, it is imperative that the simulators are of high validity and construct for trainees to practice and rehearse surgical skills to develop confidence. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  9. Effects of middle ear quasi-static stiffness on sound transmission quantified by a novel 3-axis optical force sensor.

    Science.gov (United States)

    Dobrev, Ivo; Sim, Jae Hoon; Aqtashi, Baktash; Huber, Alexander M; Linder, Thomas; Röösli, Christof

    2018-01-01

    Intra-operative quantification of the ossicle mobility could provide valuable feedback for the current status of the patient's conductive hearing. However, current methods for evaluation of middle ear mobility are mostly limited to the surgeon's subjective impression through manual palpation of the ossicles. This study investigates how middle ear transfer function is affected by stapes quasi-static stiffness of the ossicular chain. The stiffness of the middle ear is induced by a) using a novel fiber-optic 3-axis force sensor to quantify the quasi-static stiffness of the middle ear, and b) by artificial reduction of stapes mobility due to drying of the middle ear. Middle ear transfer function, defined as the ratio of the stapes footplate velocity versus the ear canal sound pressure, was measured with a single point LDV in two conditions. First, a controlled palpation force was applied at the stapes head in two in-plane (superior-inferior or posterior-anterior) directions, and at the incus lenticular process near the incudostapedial joint in the piston (lateral-medial) direction with a novel 3-axis PalpEar force sensor (Sensoptic, Losone, Switzerland), while the corresponding quasi-static displacement of the contact point was measured via a 3-axis micrometer stage. The palpation force was applied sequentially, step-wise in the range of 0.1-20 gF (1-200 mN). Second, measurements were repeated with various stages of stapes fixation, simulated by pre-load on the stapes head or drying of the temporal bone, and with severe ossicle immobilization, simulated by gluing of the stapes footplate. Simulated stapes fixation (forced drying of 5-15 min) severely decreases (20-30 dB) the low frequency (4 kHz) response. Stapes immobilization (gluing of the footplate) severely reduces (20-40 dB) the low and mid frequency response (force (Force-displacement measurements around the incudostapedial joint showed quasi-static stiffness in the range of 200-500 N/m for normal middle

  10. A Rare Case of Petrified Ear

    Directory of Open Access Journals (Sweden)

    Kathryn E. Buikema

    2012-01-01

    Full Text Available Calcification or ossification of the auricle, also referred to as petrified ear, is a rare diagnosis in dermatology. In medical literature, it has most often been attributed to trauma, hypothermia and frostbite, or hypercalcemia secondary to a metabolic or endocrine disorder, such as Addison's disease. Here, we report the clinical and radiologic findings of a 79-year-old African American male whose unilateral petrified auricle was an incidental finding. He had a preceding history of hyperparathyroidism and subsequent hypercalcemia treated with a subtotal parathyroidectomy three years prior to presentation. In addition to laboratory analysis, a history and physical examination was performed which revealed no other signs of hypercalcemia. Radiologic studies demonstrated partial ossification of the external auricular cartilage on the left side. The patient was diagnosed with the rare occurrence of a petrified ear. In light of this case, we provide a discussion concerning the possible etiologies of this diagnosis including appropriate patient evaluation and possible treatment recommendations.

  11. Ear embryonic rabdomiosarcoma. A case report

    International Nuclear Information System (INIS)

    Cueto, L.; Canabal, A.; Blanco, A.; Sabate, J.

    2002-01-01

    A case of embryonic rabdomiosarcoma in the ear of a 5-year-old girl who initially shows clinical symptoms of otitis media. The CT reveals a dense lesion of soft tissue which shows up slightly in the right external auditory channel. Also of interest were osteolytic areas in the petrous, clivus and zygomatic arch. A hypointensive lesion with marked enhancement after Gd-DPTA injection is observed. Discussed are the imaging methods used in the diagnosis of this tumor. (Author) 10 refs

  12. ElectroAcoustic Resource Site (EARS)

    OpenAIRE

    Atkinson, Simon; Landy, Leigh

    2002-01-01

    Central to the MTIRC’s electroacoustic music studies focus, EARS is supported by the AHRC’s resource enhancement scheme (ca. £170k) and Unesco (£3k). Beyond its initial goal to create the glossary (~500 entries) and related index (providing a coherent hyperlink structure for the bibliography – ~3000 entries) there are further methodological research imperatives – to offer a web-based resource that: a) Realises an accessible research resource (glossary, keyword index and bibliography) to co...

  13. Structural Metadata Research in the Ears Program

    Science.gov (United States)

    2005-01-01

    detecting structural information in the word stream (the so-called “structural MDE” portion of the EARS program); other MDE efforts on speaker ... diarization are overviewed in [13]. The rest of this paper is organized as follows. We describe the structural MDE tasks, performance measurement, and corpora...tems have only recently been introduced, with NIST reporting re- sults with the Wilcoxon signed rank test for speaker -level average score differences

  14. Turbinate surgery

    Science.gov (United States)

    Turbinectomy; Turbinoplasty; Turbinate reduction; Nasal airway surgery; Nasal obstruction - turbinate surgery ... There are several types of turbinate surgery: Turbinectomy: All or ... This can be done in several different ways, but sometimes a ...

  15. Bariatric Surgery

    Science.gov (United States)

    ... often. Each type of surgery has advantages and disadvantages. Bariatric Surgery Benefits Bariatric surgery can improve many ... Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...

  16. Lung surgery

    Science.gov (United States)

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  17. Plastic Surgery

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Plastic Surgery KidsHealth / For Teens / Plastic Surgery What's in ... her forehead lightened with a laser? What Is Plastic Surgery? Just because the name includes the word " ...

  18. A physics-based algorithm for real-time simulation of electrosurgery procedures in minimally invasive surgery.

    Science.gov (United States)

    Lu, Zhonghua; Arikatla, Venkata S; Han, Zhongqing; Allen, Brian F; De, Suvranu

    2014-12-01

    High-frequency electricity is used in the majority of surgical interventions. However, modern computer-based training and simulation systems rely on physically unrealistic models that fail to capture the interplay of the electrical, mechanical and thermal properties of biological tissue. We present a real-time and physically realistic simulation of electrosurgery by modelling the electrical, thermal and mechanical properties as three iteratively solved finite element models. To provide subfinite-element graphical rendering of vaporized tissue, a dual-mesh dynamic triangulation algorithm based on isotherms is proposed. The block compressed row storage (BCRS) structure is shown to be critical in allowing computationally efficient changes in the tissue topology due to vaporization. We have demonstrated our physics-based electrosurgery cutting algorithm through various examples. Our matrix manipulation algorithms designed for topology changes have shown low computational cost. Our simulator offers substantially greater physical fidelity compared to previous simulators that use simple geometry-based heat characterization. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Pressure equilibration in the penguin middle ear.

    Science.gov (United States)

    Sadé, Jacob; Handrich, Yves; Bernheim, Joelle; Cohen, David

    2008-01-01

    King penguins have a venous structure in the form of a corpus cavernosum (CC) in their middle ear (ME) submucosa. The CC may be viewed as a special organelle that can change ME volume for pressure equilibration during deep-sea diving it is a pressure regulating organelle (PRO). A similar CC and muscles also surround the external ear (EE) and may constrict it, isolating the tympanic membrane from the outside. A CC was previously found also in the ME of marine diving mammals and can be expected to exist in other deep diving animals, such as marine turtles. Marine animals require equalization of middle ear (ME) pressure when diving hundreds or thousands of meters to catch prey. We investigated what mechanism enables king penguins to protect their ME when they dive to great depths. Biopsies and serial sections of the ME and the EE of the deep diving king penguin (Aptenodytes patagonicus) were examined microscopically. It was demonstrated that the penguin ME has an extensive network of small and large submucosal venous sinuses. This venous formation, a corpus cavernosum, can expand and potentially 'flood' the ME almost completely on diving, thus elevating ME pressure and reducing the ME space. The EE has a similar protective mechanism.

  20. Ear recognition from one sample per person.

    Directory of Open Access Journals (Sweden)

    Long Chen

    Full Text Available Biometrics has the advantages of efficiency and convenience in identity authentication. As one of the most promising biometric-based methods, ear recognition has received broad attention and research. Previous studies have achieved remarkable performance with multiple samples per person (MSPP in the gallery. However, most conventional methods are insufficient when there is only one sample per person (OSPP available in the gallery. To solve the OSPP problem by maximizing the use of a single sample, this paper proposes a hybrid multi-keypoint descriptor sparse representation-based classification (MKD-SRC ear recognition approach based on 2D and 3D information. Because most 3D sensors capture 3D data accessorizing the corresponding 2D data, it is sensible to use both types of information. First, the ear region is extracted from the profile. Second, keypoints are detected and described for both the 2D texture image and 3D range image. Then, the hybrid MKD-SRC algorithm is used to complete the recognition with only OSPP in the gallery. Experimental results on a benchmark dataset have demonstrated the feasibility and effectiveness of the proposed method in resolving the OSPP problem. A Rank-one recognition rate of 96.4% is achieved for a gallery of 415 subjects, and the time involved in the computation is satisfactory compared to conventional methods.

  1. Ear recognition from one sample per person.

    Science.gov (United States)

    Chen, Long; Mu, Zhichun; Zhang, Baoqing; Zhang, Yi

    2015-01-01

    Biometrics has the advantages of efficiency and convenience in identity authentication. As one of the most promising biometric-based methods, ear recognition has received broad attention and research. Previous studies have achieved remarkable performance with multiple samples per person (MSPP) in the gallery. However, most conventional methods are insufficient when there is only one sample per person (OSPP) available in the gallery. To solve the OSPP problem by maximizing the use of a single sample, this paper proposes a hybrid multi-keypoint descriptor sparse representation-based classification (MKD-SRC) ear recognition approach based on 2D and 3D information. Because most 3D sensors capture 3D data accessorizing the corresponding 2D data, it is sensible to use both types of information. First, the ear region is extracted from the profile. Second, keypoints are detected and described for both the 2D texture image and 3D range image. Then, the hybrid MKD-SRC algorithm is used to complete the recognition with only OSPP in the gallery. Experimental results on a benchmark dataset have demonstrated the feasibility and effectiveness of the proposed method in resolving the OSPP problem. A Rank-one recognition rate of 96.4% is achieved for a gallery of 415 subjects, and the time involved in the computation is satisfactory compared to conventional methods.

  2. Pathology of ear hematomas in swine.

    Science.gov (United States)

    Drolet, Richard; Hélie, Pierre; D'Allaire, Sylvie

    2016-05-01

    The objectives of our study were to describe the pathology of ear hematomas in swine and to add to the comprehension of the pathogenesis of this condition. The pathogenesis of aural hematomas has been studied mainly in dogs; however, disagreements exist about the precise anatomic location of the hemorrhage. Sixteen pigs with ear hematoma at various stages of development were included in this study. The pigs were submitted for routine autopsy for various and unrelated reasons over a period of several years. Based on gross examination, the 16 cases of aural hematomas were subjectively classified as acute (n = 6), subacute (n = 3), and chronic (n = 7). The age of the animals at the time of autopsy ranged from 2 weeks to adulthood, with all acute cases being hematoma developed predominantly in a subperichondral location on both sides of the cartilaginous plate simultaneously. Within these same cases, there were also some areas in which blood-filled clefts had formed within the cartilage itself. Besides fibroplasia, neoformation of cartilage was found to represent a significant part of the repair process. All chronic cases were characterized on cross-section of the ear by the presence of at least 2 distinct, wavy, focally folded, and roughly parallel plates of cartilage separated from each other by fibrous tissue. © 2016 The Author(s).

  3. Otoscopy simulation training in a classroom setting: a novel approach to teaching otoscopy to medical students.

    Science.gov (United States)

    Davies, Joel; Djelic, Lucas; Campisi, Paolo; Forte, Vito; Chiodo, Albino

    2014-11-01

    To determine the effectiveness of using of an otoscopy stimulator to teach medical students the primary principles of otoscopy in large group training sessions and improve their confidence in making otologic diagnoses. Cross-sectional survey design. In March 2013, the Department of Otolaryngology-Head and Neck Surgery held a large-scale otoscopy simulator teaching session at the MaRS Innovation Center for 92 first and second year University of Toronto medical students. Following the training session, students were provided with an optional electronic, nine-question survey related to their experience with learning otoscopy using the simulators alone, and in comparison to traditional methods of teaching. Thirty-four medical students completed the survey. Ninety-one percent of the respondents indicated that the overall quality of the event was either very good or excellent. A total of 71% of respondents either agreed, or strongly agreed, that the otoscopy simulator training session improved their confidence in diagnosing pathologies of the ear. The majority (70%) of students indicated that the training session had stimulated their interest in otolaryngology-head and neck surgery as a medical specialty. Organizing large-group otoscopy simulator training sessions is one method whereby students can become familiar with a wide variety of pathologies of the ear and improve both their diagnostic accuracy and their confidence in making otologic diagnoses. NA © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Virtual reality in laparoscopic surgery.

    Science.gov (United States)

    Uranüs, Selman; Yanik, Mustafa; Bretthauer, Georg

    2004-01-01

    Although the many advantages of laparoscopic surgery have made it an established technique, training in laparoscopic surgery posed problems not encountered in conventional surgical training. Virtual reality simulators open up new perspectives for training in laparoscopic surgery. Under realistic conditions in real time, trainees can tailor their sessions with the VR simulator to suit their needs and goals, and can repeat exercises as often as they wish. VR simulators reduce the number of experimental animals needed for training purposes and are suited to the pursuit of research in laparoscopic surgery.

  5. Alterations in the Contra lateral Ear in Chronic Otitis Media

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Damghani

    2013-03-01

    Full Text Available Introduction: Chronic otitis media (COM, a persistent and durable inflammation and infection of the middle ear, is a common disorder. Alterations in the contralateral ear in sufferers have been observed in recent years. Because only a few studies have been reported in this area, we performed this study in order to assess alterations in the contralateral ear of patients with COM.   Materials and Methods: Cross-sectional and descriptive methods were used in 100 patients with COM who were selected for surgical treatment and admitted to hospital. An information form was completed for all patients including demographic data, medical history of otoscopy and paraclinical examinations such as pure tone audiometry (PTA, tympanometry, Schuller radiography, and high resolution computed tomography (HRCT. All data were processed using SPSS (version 18 software and descriptive statistical tests.   Results: According to otoscopy, PTA, tympanometry and graphical analysis, 60% of patients experienced disorders of the contralateral ear. Otoscopy analysis showed 54% of patients had a disorder of the contralateral ear, with the most common disorder being perforation of the ear drum. PTA showed a 48% incidence of contralateral ear problems (85% conductive hearing impairment; 12.5% sensorineural hearing impairment; 1.2% mixed. A total of 73.2% of patients with conductive hearing loss had a problem across all frequencies, while half of the patients with sensorineural hearing impairment had problems at frequencies greater than 1000 Hz. According to tympanometry, 38% of patients had problem in the contralateral ear. HRCT and Schuller graphical analyses indicated 31.5% and 36% occurrence of contralateral ear disorders, respectively.   Conclusion:  More than 50% of patients with COM in one ear have a chance of also presenting with the disease in the other ear. Outcomes of this study and previous studies have shown that COM should not be perceived as a disease limited

  6. Quantitative computed tomography for the prediction of pulmonary function after lung cancer surgery: a simple method using simulation software.

    Science.gov (United States)

    Ueda, Kazuhiro; Tanaka, Toshiki; Li, Tao-Sheng; Tanaka, Nobuyuki; Hamano, Kimikazu

    2009-03-01

    The prediction of pulmonary functional reserve is mandatory in therapeutic decision-making for patients with resectable lung cancer, especially those with underlying lung disease. Volumetric analysis in combination with densitometric analysis of the affected lung lobe or segment with quantitative computed tomography (CT) helps to identify residual pulmonary function, although the utility of this modality needs investigation. The subjects of this prospective study were 30 patients with resectable lung cancer. A three-dimensional CT lung model was created with voxels representing normal lung attenuation (-600 to -910 Hounsfield units). Residual pulmonary function was predicted by drawing a boundary line between the lung to be preserved and that to be resected, directly on the lung model. The predicted values were correlated with the postoperative measured values. The predicted and measured values corresponded well (r=0.89, plung cancer surgery and helped to identify patients whose functional reserves are likely to be underestimated. Hence, this modality should be utilized for patients with marginal pulmonary function.

  7. Finite Element Simulation and Additive Manufacturing of Stiffness-Matched NiTi Fixation Hardware for Mandibular Reconstruction Surgery

    Directory of Open Access Journals (Sweden)

    Ahmadreza Jahadakbar

    2016-12-01

    Full Text Available Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, we present a study of mandibular reconstruction that uses a dry cadaver mandible to validate our geometric and biomechanical design and fabrication (i.e., 3D printing of NiTi skeletal fixation hardware. Based on the reference-dried mandible, we have developed a Finite Element model to evaluate the performance of the proposed fixation. Our results show a closer-to-normal stress distribution and an enhanced contact pressure at the bone graft interface than would be in the case with Ti-6Al-4V off-the-shelf fixation hardware. The porous fixation plates used in this study were fabricated by selective laser melting.

  8. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure.

    Science.gov (United States)

    Péus, Dominik; Dobrev, Ivo; Prochazka, Lukas; Thoele, Konrad; Dalbert, Adrian; Boss, Andreas; Newcomb, Nicolas; Probst, Rudolf; Röösli, Christof; Sim, Jae Hoon; Huber, Alexander; Pfiffner, Flurin

    2017-08-01

    Animals are frequently used for the development and testing of new hearing devices. Dimensions of the middle ear and cochlea differ significantly between humans and commonly used animals, such as rodents or cats. The sheep cochlea is anatomically more like the human cochlea in size and number of turns. This study investigated the middle-ear ossicular velocities and intracochlear sound pressure (ICSP) in sheep temporal bones, with the aim of characterizing the sheep as an experimental model for implantable hearing devices. Measurements were made on fresh sheep temporal bones. Velocity responses of the middle ear ossicles at the umbo, long process of the incus and stapes footplate were measured in the frequency range of 0.25-8 kHz using a laser Doppler vibrometer system. Results were normalized by the corresponding sound pressure level in the external ear canal (P EC ). Sequentially, ICSPs at the scala vestibuli and tympani were then recorded with custom MEMS-based hydrophones, while presenting identical acoustic stimuli. The sheep middle ear transmitted most effectively around 4.8 kHz, with a maximum stapes velocity of 0.2 mm/s/Pa. At the same frequency, the ICSP measurements in the scala vestibuli and tympani showed the maximum gain relative to the P EC (24 dB and 5 dB, respectively). The greatest pressure difference across the cochlear partition occurred between 4 and 6 kHz. A comparison between the results of this study and human reference data showed middle-ear resonance and best cochlear sensitivity at higher frequencies in sheep. In summary, sheep can be an appropriate large animal model for research and development of implantable hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Effect of the Yield Stress and r-value Distribution on the Earing Profile of Cup Drawing with Yld2000-2d Yield Function

    Science.gov (United States)

    Lou, Yanshan; Bae, Gihyun; Lee, Changsoo; Huh, Hoon

    2010-06-01

    This paper deals with the effect of the yield stress and r-value distribution on the earing in the cup drawing. The anisotropic yield function, Yld2000-2d yield function, is selected to describe the anisotropy of two metal sheets, 719B and AA5182-O. The tool dimension is referred from the Benchmark problem of NUMISHEET'2002. The Downhill Simplex method is applied to identify the anisotropic coefficients in Yld2000-2d yield function. Simulations of the drawing process are performed to investigate the earing profile of two materials. The earing profiles obtained from simulations are compared with the analytical model developed by Hosford and Caddell. Simulations are conducted with respect to the change of the yield stress and r-value distribution, respectively. The correlation between the anisotropy and the earing tendency is investigated based on simulation data. Finally, the earing mechanism is analyzed through the deformation process of the blank during the cup deep drawing. It can be concluded that ears locate at angular positions with lower yield stress and higher r-value while the valleys appear at the angular position with higher yield stress and lower r-value. The effect of the yield stress distribution is more important for the cup height distribution than that of the r-value distribution.

  10. [Diagnostic value of high-resolution computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Sun, Xiaowei; Ding, Yuanping; Zhang, Jianji; Chen, Ying; Xu, Anting; Dou, Fenfen; Zhang, Zihe

    2007-02-01

    To observe the inner ear structure with volume rendering (VR) reconstruction and to evaluate the role of high-resolution computed tomography (HRCT) in congenital inner ear malformations. HRCT scanning was performed in 10 patients (20 ears) without ear disease (control group) and 7 patients (11 ears) with inner ear malformations (IEM group) and the original data was processed with VR reconstruction. The inner ear osseous labyrinth structure in the images generated by these techniques was observed respectively in the normal ears and malformation ears. The inner ear osseous labyrinth structure and the relationship was displayed clearly in VR imaging in the control group,meanwhile, characters and degree of malformed structure were also displayed clearly in the IEA group. Of seven patients (11 ears) with congenital inner ear malformations, the axial, MPR and VR images can display the site and degree in 9 ears. VR images were superior to the axial images in displaying the malformations in 2 ears with the small lateral semicircular canal malformations. The malformations included Mondini deformity (7 ears), vestibular and semicircular canal malformations (3 ears), vestibular aqueduct dilate (7 ears, of which 6 ears accompanied by other malformations) , the internal auditory canal malformation (2 ears, all accompanied by other malformations). HRCT can display the normal structure of bone inner ear through high quality VR reconstructions. VR images can also display the site and degree of the malformations three-dimensionally and intuitively. HRCT is valuable in diagnosing the inner ear malformation.

  11. Efficacy of elective nodal irradiation in skin squamous cell carcinoma of the face, ears, and scalp

    OpenAIRE

    Wray, Justin; Amdur, Robert J.; Morris, Christopher G.; Werning, John; Mendenhall, William M.

    2015-01-01

    Background In patients at high risk for regional node metastasis from squamous cell carcinoma (SCC) of the skin of the face, ear, or scalp, radiotherapy to the regional nodes is an alternative to parotid or neck surgery. Data on the efficacy of elective nodal radiotherapy in this setting are scarce such that there is no publication specifically addressing the subject. The purpose of our study is to fill this void in the skin cancer literature. Methods This is a single-institution study of out...

  12. Presbycusis: do we have a third ear?

    Science.gov (United States)

    Reis, Luis Roque; Escada, Pedro

    Age-related hearing changes are the most frequent cause of sensorineural hearing loss in adults. In the literature no studies exist concerning the importance of speechreading in individuals with presbycusis. Equally, no such studies have been carried out with speakers of the Portuguese (Portugal) language. To evaluate whether the intelligibility of words in presbycusis is improved by speechreading, in such a way that looking at the interlocutor's face while he is talking functions like a "third ear", and to determine the statistical relevance of the intelligibility improvement by speechreading. Eleven individuals (22 ears) with bilateral and symmetrical sensorineural hearing loss compatible with presbycusis were evaluated. The subjects were aged between 57 and 82 years, with an average of 70±11.51 years and median of 69.5 years. A complete medical and audiological profile of each patient was created and all patients were submitted to a vocal audiogram, without and with observation of the audiologist's face. A descriptive and analytical statistical analysis was performed (Shapiro-Wilk and t pairs tests) adopting the significance level of 0.05 (5%). We noticed better performance in intelligibility with speechreading. The p-value was zero (ppresbycusis in this study, performed better on spoken word intelligibility when the hearing of those words was associated with speechreading. This phenomenon helps in such a way that observation of the interlocutor's face works like a "third ear". Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  13. Potential cost saving of Epoetin alfa in elective hip or knee surgery due to reduction in blood transfusions and their side effects: a discrete-event simulation model.

    Directory of Open Access Journals (Sweden)

    Jörg Tomeczkowski

    Full Text Available OBJECTIVES: Transfusion of allogeneic blood is still common in orthopedic surgery. This analysis evaluates from the perspective of a German hospital the potential cost savings of Epoetin alfa (EPO compared to predonated autologous blood transfusions or to a nobloodconservationstrategy (allogeneic blood transfusion strategyduring elective hip and knee replacement surgery. METHODS: Individual patients (N = 50,000 were simulated based on data from controlled trials, the German DRG institute (InEK and various publications and entered into a stochastic model (Monte-Carlo of three treatment arms: EPO, preoperative autologous donation and nobloodconservationstrategy. All three strategies lead to a different risk for an allogeneic blood transfusion. The model focused on the costs and events of the three different procedures. The costs were obtained from clinical trial databases, the German DRG system, patient records and medical publications: transfusion (allogeneic red blood cells: €320/unit and autologous red blood cells: €250/unit, pneumonia treatment (€5,000, and length of stay (€300/day. Probabilistic sensitivity analyses were performed to determine which factors had an influence on the model's clinical and cost outcomes. RESULTS: At acquisition costs of €200/40,000 IU EPO is cost saving compared to autologous blood donation, and cost-effective compared to a nobloodconservationstrategy. The results were most sensitive to the cost of EPO, blood units and hospital days. CONCLUSIONS: EPO might become an attractive blood conservation strategy for anemic patients at reasonable costs due to the reduction in allogeneic blood transfusions, in the modeled incidence of transfusion-associated pneumonia andthe prolongedlength of stay.

  14. Potential cost saving of Epoetin alfa in elective hip or knee surgery due to reduction in blood transfusions and their side effects: a discrete-event simulation model.

    Science.gov (United States)

    Tomeczkowski, Jörg; Stern, Sean; Müller, Alfred; von Heymann, Christian

    2013-01-01

    Transfusion of allogeneic blood is still common in orthopedic surgery. This analysis evaluates from the perspective of a German hospital the potential cost savings of Epoetin alfa (EPO) compared to predonated autologous blood transfusions or to a nobloodconservationstrategy (allogeneic blood transfusion strategy)during elective hip and knee replacement surgery. Individual patients (N = 50,000) were simulated based on data from controlled trials, the German DRG institute (InEK) and various publications and entered into a stochastic model (Monte-Carlo) of three treatment arms: EPO, preoperative autologous donation and nobloodconservationstrategy. All three strategies lead to a different risk for an allogeneic blood transfusion. The model focused on the costs and events of the three different procedures. The costs were obtained from clinical trial databases, the German DRG system, patient records and medical publications: transfusion (allogeneic red blood cells: €320/unit and autologous red blood cells: €250/unit), pneumonia treatment (€5,000), and length of stay (€300/day). Probabilistic sensitivity analyses were performed to determine which factors had an influence on the model's clinical and cost outcomes. At acquisition costs of €200/40,000 IU EPO is cost saving compared to autologous blood donation, and cost-effective compared to a nobloodconservationstrategy. The results were most sensitive to the cost of EPO, blood units and hospital days. EPO might become an attractive blood conservation strategy for anemic patients at reasonable costs due to the reduction in allogeneic blood transfusions, in the modeled incidence of transfusion-associated pneumonia andthe prolongedlength of stay.

  15. Analytical model of internally coupled ears

    DEFF Research Database (Denmark)

    Vossen, Christine; Christensen-Dalsgaard, Jakob; Leo van Hemmen, J

    2010-01-01

    Lizards and many birds possess a specialized hearing mechanism: internally coupled ears where the tympanic membranes connect through a large mouth cavity so that the vibrations of the tympanic membranes influence each other. This coupling enhances the phase differences and creates amplitude...... additionally provides the opportunity to incorporate the effect of the asymmetrically attached columella, which leads to the activation of higher membrane vibration modes. Incorporating this effect, the analytical model can explain measurements taken from the tympanic membrane of a living lizard, for example...

  16. Vitamin D receptor deficiency impairs inner ear development in zebrafish

    International Nuclear Information System (INIS)

    Kwon, Hye-Joo

    2016-01-01

    The biological actions of vitamin D are largely mediated through binding to the vitamin D receptor (VDR), a member of the nuclear hormone receptor family, which regulates gene expression in a wide variety of tissues and cells. Mutations in VDR gene have been implicated in ear disorders (hearing loss and balance disorder) but the mechanisms are not well established. In this study, to investigate the role of VDR in inner ear development, morpholino-mediated gene knockdown approaches were used in zebrafish model system. Two paralogs for VDR, vdra and vdrb, have been identified in zebrafish. Knockdown of vdra had no effect on ear development, whereas knockdown of vdrb displayed morphological ear defects including smaller otic vesicles with malformed semicircular canals and abnormal otoliths. Loss-of-vdrb resulted in down-regulation of pre-otic markers, pax8 and pax2a, indicating impairment of otic induction. Furthermore, zebrafish embryos lacking vdrb produced fewer sensory hair cells in the ears and showed disruption of balance and motor coordination. These data reveal that VDR signaling plays an important role in ear development. - Highlights: • VDR signaling is involved in ear development. • Knockdown of vdrb causes inner ear malformations during embryogenesis. • Knockdown of vdrb affects otic placode induction. • Knockdown of vdrb reduces the number of sensory hair cells in the inner ear. • Knockdown of vdrb disrupts balance and motor coordination.

  17. Ear replanatation: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Krešimir Božikov

    2013-10-01

    Full Text Available Background: Total ear amputation is a rare accident. The most common causes are traffic accidents (33 %, followed by fights (28 %. In 1980, Pennington et al. reported the first successful microsurgical ear replantation in a 29-year old man.Methods: An English literature review of trauma cases of total ear amputation showed only 13 successful replantations with arterial and venous microanastomoses. We present a case report of successful total ear replantation with arterial and vein microanastomoses in a 17-year old boy.Results: Our ear replantation with both arterial and venous anastomoses performed was successful and we achieved an excellent aesthetic outcome.Conclusion: The reason for such a low number of successful ear replantations is technical challenge due to small vessel diameter, difficult vessel identification, vessel approach and concomitant avulsion injury. The best aesthetic result in ear reconstruction is achieved by microsurgical replantation. The surgical technique depends on the intraoperative findings. Since ear replantation is a very challenging procedure, a microsurgeon needs to discuss with the patient the risk of partial/total necrosis of the replanted ear and the possibilities of other reconstructive options.

  18. Incorporating anthropometry into design of ear-related products.

    Science.gov (United States)

    Liu, Bor-Shong

    2008-01-01

    To achieve mass customization and collaborative product design, human factors and ergonomics should play a key development role. The purpose of this study was to provide product designers with the anthropometic dimensions of outer ears for different demographic data, including gender and age. The second purpose was to compare the dimensions of various ear-related products (i.e., earphone, bluetooth earphone and ear-cup earphone) with the anthropometic database and recommend appropriate solutions for design. Two hundred subjects aged 20-59 was selected for this study and divided into four age stratifications. Further, three different dimensions of the outer ear (i.e., the earhole length, the ear connection length and the length of the pinna) were measured by superimposed grid photographic technique. The analysis of variance (ANOVA) was used to investigate the effects of gender, and age on ear dimensions. The results showed that all ear dimensions had significant gender effects. A comparison between the anthropometric dimensions and those of current products revealed that most current ear-related products need to be redesigned using anthropometric data. The shapes of earhole and pinna are not circular. Consequently, ear products need to be elongated so that users may feel more comfortably and not have the product slip off easily.

  19. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  20. Preoperative evaluation of the congenital aural atresia on computed tomography; an analysis of the severity of the deformity of the middle ear and mastoid

    Energy Technology Data Exchange (ETDEWEB)

    Tasar, Mustafa [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey)]. E-mail: tasarmus@yahoo.com; Yetiser, Sertac [Gulhane Medical School, Department of ORL and HNS (Turkey); Yildirim, Duzgun [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey); Bozlar, Ugur [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey); Tasar, M. Aysin [Ankara Hospital, Department of Pediatrics (Turkey); Saglam, Mutlu [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey); Ugurel, M. Sahin [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey); Battal, Bilal [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey); Ucoz, Taner [Gulhane Medical School, Department of Radiology, Etlik-Ankara (Turkey)

    2007-04-15

    Objective: To compare the development of temporal bone in normal and atretic ears and to assess some radiological landmarks that could be important in the hearing restoration interventions in such patients. Material and methods: Thirty-five patients with 40 atretic external ears were evaluated with temporal bone CT and compared to a control group of 40 normal ears retrospectively. Using comparable slice levels in all patients, the course and the caliper of the facial canal, the surface area of the incus and malleus, the level of mastoid aeration, the location and anteroposterior diameters of the jugular bulb and sigmoid sinus, the direction and the caliber of the tympanic bony part of the Eustachian tube, area of the middle ear cavity, distance from facial nerve to incudomalleolar joint, to the vestibule and to the jugular bulb were included in the assessment. Non-parametric and parametric statistical tests were used for comparison. Results: In atretic ears middle ear sectional area was found to be smaller at the equivalent plane as compared to control subjects (mean area index: 19.3 mm{sup 2} versus 47.4 mm{sup 2}). Mastoid aeration was low in general and the ossicles in the atretic ears were hypoplastic (mean ossicular sectional area: 8.3 mm{sup 2} versus 11 mm{sup 2}). The distance from the jugular bulb to the facial nerve was significantly lower (mean: 6.2 mm versus 6.8 mm) (p < 0.05) in the atretic ears. Facial canal caliber, distance from the facial canal to the incudomalleolar joint and distance from the facial canal to the vestibule in the atretic ears (means: 1.49, 2.93 and 1.82, respectively) did not show statistically significant difference from the control subjects (means: 1.44, 2.91 and 1.83, respectively) (p > 0.05 for all). Conclusion: External ear atresia is significantly associated with middle ear and mastoid abnormalities. The ossicles were underdeveloped which always have to be considered during reconstructive surgery. Radiologically, in the

  1. Proton Minibeam Radiation Therapy Reduces Side Effects in an In Vivo Mouse Ear Model

    Energy Technology Data Exchange (ETDEWEB)

    Girst, Stefanie, E-mail: stefanie.girst@unibw.de [Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg (Germany); Greubel, Christoph; Reindl, Judith [Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg (Germany); Siebenwirth, Christian [Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg (Germany); Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Zlobinskaya, Olga [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Walsh, Dietrich W.M. [Institut für Angewandte Physik und Messtechnik (LRT2), Universität der Bundeswehr München, Neubiberg (Germany); Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Ilicic, Katarina [Department of Radiation Oncology, Klinikum rechts der Isar, Technische Universität München, Munich (Germany); Aichler, Michaela; Walch, Axel [Research Unit Analytical Pathology, Helmholtz Zentrum München, German Research Center for Environmental Health, Oberschleißheim (Germany); and others

    2016-05-01

    Purpose: Proton minibeam radiation therapy is a novel approach to minimize normal tissue damage in the entrance channel by spatial fractionation while keeping tumor control through a homogeneous tumor dose using beam widening with an increasing track length. In the present study, the dose distributions for homogeneous broad beam and minibeam irradiation sessions were simulated. Also, in an animal study, acute normal tissue side effects of proton minibeam irradiation were compared with homogeneous irradiation in a tumor-free mouse ear model to account for the complex effects on the immune system and vasculature in an in vivo normal tissue model. Methods and Materials: At the ion microprobe SNAKE, 20-MeV protons were administered to the central part (7.2 × 7.2 mm{sup 2}) of the ear of BALB/c mice, using either a homogeneous field with a dose of 60 Gy or 16 minibeams with a nominal 6000 Gy (4 × 4 minibeams, size 0.18 × 0.18 mm{sup 2}, with a distance of 1.8 mm). The same average dose was used over the irradiated area. Results: No ear swelling or other skin reactions were observed at any point after minibeam irradiation. In contrast, significant ear swelling (up to fourfold), erythema, and desquamation developed in homogeneously irradiated ears 3 to 4 weeks after irradiation. Hair loss and the disappearance of sebaceous glands were only detected in the homogeneously irradiated fields. Conclusions: These results show that proton minibeam radiation therapy results in reduced adverse effects compared with conventional homogeneous broad-beam irradiation and, therefore, might have the potential to decrease the incidence of side effects resulting from clinical proton and/or heavy ion therapy.

  2. Face and content validity of a virtual-reality simulator for myringotomy with tube placement.

    Science.gov (United States)

    Huang, Caiwen; Cheng, Horace; Bureau, Yves; Agrawal, Sumit K; Ladak, Hanif M

    2015-10-20

    Myringotomy with tube insertion can be challenging for junior Otolaryngology residents as it is one of the first microscopic procedures they encounter. The Western myringotomy simulator was developed to allow trainees to practice microscope positioning, myringotomy, and tube placement. This virtual-reality simulator is viewed in stereoscopic 3D, and a haptic device is used to manipulate the digital ear model and surgical tools. To assess the face and content validity of the Western myringotomy simulator. The myringotomy simulator was integrated with new modules to allow speculum placement, manipulation of an operative microscope, and insertion of the ventilation tube through a deformable tympanic membrane. A questionnaire was developed in consultation with instructing surgeons. Fourteen face validity questions focused on the anatomy of the ear, simulation of the operative microscope, appearance and movement of the surgical instruments, deformation and cutting of the eardrum, and myringotomy tube insertion. Six content validity questions focused on training potential on surgical tasks such as speculum placement, microscope positioning, tool navigation, ear anatomy, myringotomy creation and tube insertion. A total of 12 participants from the Department of Otolaryngology-Head and Neck Surgery were recruited for the study. Prior to completing the questionnaire, participants were oriented to the simulator and given unlimited time to practice until they were comfortable with all of its aspects. Responses to 12 of the 14 questions on face validity were predominantly positive. One issue of concern was with contact modeling related to tube insertion into the eardrum, and the second was with the movement of the blade and forceps. The former could be resolved by using a higher resolution digital model for the eardrum to improve contact localization. The latter could be resolved by using a higher fidelity haptic device. With regard to content validity, 64% of the responses

  3. Induced thermal resistance in the mouse ear

    International Nuclear Information System (INIS)

    Law, M.P.; Coultas, P.G.; Field, S.B.

    1979-01-01

    The mouse ear (pinna) was used to investigate the effect of two hyperthermic treatments. Heating was by immersion in hot water at 43.5 0 C. A single treatment of about 50 minutes was required to cause necrosis in 50% of the ears treated. When heat treatment was given in two equal fractions the total heating time had to be increased if the interval between fractions was greater than four hours. By 24 hours a total treatment of about 100 minutes was required, indicating almost complete recovery from the first heating. Priming treatments at 43.5 0 C induced thermal resistance to a second heat treatment at 43.5 0 C. Maximum resistance was observed one day after a 20 minute priming and two days after a 40 minute priming, when the heating time had to be increased to 120 minutes, an increase by a factor of 2.4. Shorter priming treatments induced less resistance, the minimum heating time to produce an effect being two minutes. In all cases the effect decreased during the next four to five days. These results indicate that the reduced response of tissues to fractionated hyperthermia is due both to the repair of sublethal heat damage and induction of thermal resistance. (author)

  4. Middle ear function in sinonasal polyposis.

    Science.gov (United States)

    Bakhshaee, Mehdi; Ardakani, Hossein Payedar; Ghazizadeh, Amir Hossain; Movahed, Rahman; Jarahi, Lida; Rajati, Mohsen

    2016-10-01

    Nasal airway patency has long been considered a major factor in ear health. The aim of this study was to determine the effect of sinonasal polyposis on middle ear and eustachian tube (ET) functionality. Forty-four individuals with polyposis, 23 with non-polyposis nasal obstruction, and 23 healthy controls were enrolled. Demographic, clinical and imaging data of all participants were collected and ET function tests and audiologic tests were performed. Hearing loss (p = 0.02), flat tympanogram (p = 0.02), disturbed Toynbee and Valsalva tests (p = 0.01), and the prevalence of allergy (p = 0.04) and purulent nasal discharge (p polyposis group than the other groups. Regression analysis revealed that infection and allergy have more important roles in ET function than the nasal obstruction. Polyposis could impede ET function; however, it is probably not because of its obstructive nature, but because of the associated increased risk of infection.

  5. Wearable ear EEG for brain interfacing

    Science.gov (United States)

    Schroeder, Eric D.; Walker, Nicholas; Danko, Amanda S.

    2017-02-01

    Brain-computer interfaces (BCIs) measuring electrical activity via electroencephalogram (EEG) have evolved beyond clinical applications to become wireless consumer products. Typically marketed for meditation and neu- rotherapy, these devices are limited in scope and currently too obtrusive to be a ubiquitous wearable. Stemming from recent advancements made in hearing aid technology, wearables have been shrinking to the point that the necessary sensors, circuitry, and batteries can be fit into a small in-ear wearable device. In this work, an ear-EEG device is created with a novel system for artifact removal and signal interpretation. The small, compact, cost-effective, and discreet device is demonstrated against existing consumer electronics in this space for its signal quality, comfort, and usability. A custom mobile application is developed to process raw EEG from each device and display interpreted data to the user. Artifact removal and signal classification is accomplished via a combination of support matrix machines (SMMs) and soft thresholding of relevant statistical properties.

  6. Inflammatory diseases of the middle ear

    International Nuclear Information System (INIS)

    Boasquevisque, Gustavo Santos; Andrade, Carlos Ramon de; Boasquevisque, Edson Mendes

    2008-01-01

    Objective: to determine the aspects and frequency of middle ear alterations at computed tomography and magnetic resonance imaging in patients with clinical suspicion for middle ear inflammatory disease. Material and method: imaging examination results of 95 patients (95 computed tomography and 1 magnetic resonance imaging) were compared with the results of otology, imaging and surgical findings. Results: fifty-two patients had normal imaging results. Forty-three patients had radiologic alterations compared to the physical, otology and histopathologic exams: acute otomastoiditis in 2 patients (4.6%), unilateral chronic otomastoiditis in 9 (21.0%), bilateral chronic otomastoiditis in 2 (4.6%), unilateral cholesteatoma in 26 (60.5%), and bilateral cholesteatoma in 4 (9.3%). Conclusion: computed tomography was able to demonstrate the characteristics of the lesions and found complications in majority of the cases. Magnetic resonance imaging was used only in one patient to rule out scar and cholesteatoma. The knowledge of the clinical and otologic data enables the radiologist to elaborate a more appropriate interpretation of the imaging findings. (author)

  7. Movement of the external ear in human embryo.

    Science.gov (United States)

    Kagurasho, Miho; Yamada, Shigehito; Uwabe, Chigako; Kose, Katsumi; Takakuwa, Tetsuya

    2012-02-01

    External ears, one of the major face components, show an interesting movement during craniofacial morphogenesis in human embryo. The present study was performed to see if movement of the external ears in a human embryo could be explained by differential growth. In all, 171 samples between Carnegie stage (CS) 17 and CS 23 were selected from MR image datasets of human embryos obtained from the Kyoto Collection of Human Embryos. The three-dimensional absolute position of 13 representative anatomical landmarks, including external and internal ears, from MRI data was traced to evaluate the movement between the different stages with identical magnification. Two different sets of reference axes were selected for evaluation and comparison of the movements. When the pituitary gland and the first cervical vertebra were selected as a reference axis, the 13 anatomical landmarks of the face spread out within the same region as the embryo enlarged and changed shape. The external ear did move mainly laterally, but not cranially. The distance between the external and internal ear stayed approximately constant. Three-dimensionally, the external ear located in the caudal ventral parts of the internal ear in CS 17, moved mainly laterally until CS 23. When surface landmarks eyes and mouth were selected as a reference axis, external ears moved from the caudal lateral ventral region to the position between eyes and mouth during development. The results indicate that movement of all anatomical landmarks, including external and internal ears, can be explained by differential growth. Also, when the external ear is recognized as one of the facial landmarks and having a relative position to other landmarks such as the eyes and mouth, the external ears seem to move cranially. © 2012 Kagurasho et al; licensee BioMed Central Ltd.

  8. Human Emotion and Response in Surgery (HEARS): a simulation-based curriculum for communication skills, systems-based practice, and professionalism in surgical residency training.

    Science.gov (United States)

    Larkin, Anne C; Cahan, Mitchell A; Whalen, Giles; Hatem, David; Starr, Susan; Haley, Heather-Lyn; Litwin, Demetrius; Sullivan, Kate; Quirk, Mark

    2010-08-01

    This study examines the development and implementation of a pilot human factors curriculum during a 2-year period. It is one component of a comprehensive 5-year human factors curriculum spanning core competencies of interpersonal and communication skills, systems-based practice, and professionalism and using low-and high-fidelity simulation techniques. Members of the Department of Surgery and the Center for Clinical Communication and Performance Outcomes jointly constructed a curriculum for PGY1 and PGY2 residents on topics ranging from challenging communication to time and stress management. Video demonstrations, triggers, and simulated scenarios involving acting patients were created by surgeons and medical educators. Pre- and postintervention measures were obtained for communication skills, perceived stress level, and teamwork. Communication skills were evaluated using a series of video vignettes. The validated Perceived Stress Scale and Teamwork and Patient Safety Attitudes survey were used. Residents' perceptions of the program were also measured. Twenty-seven PGY1 residents and 15 PGY2 residents participated during 2 years. Analyses of video vignette tests indicated significant improvement in empathic communication for PGY1 (t = 3.62, p = 0.001) and PGY2 (t = 5.00, p = 0.004). There were no significant changes to teamwork attitudes. Perceived levels of stress became considerably higher. PGY1 residents reported trying 1 to 3 strategies taught in the time management session, with 60% to 75% reporting improvement post-training. This unique and comprehensive human factors curriculum is shown to be effective in building communication competency for junior-level residents in the human and emotional aspects of surgical training and practice. Continued refinement and ongoing data acquisition and analyses are underway. Copyright 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation.

    Science.gov (United States)

    Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime; Liebschner, Michael A K; Xia, James J

    2018-04-01

    Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians' need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical

  10. Robotic surgery

    Science.gov (United States)

    ... with this type of surgery give it some advantages over standard endoscopic techniques. The surgeon can make ... Elsevier Saunders; 2015:chap 87. Muller CL, Fried GM. Emerging technology in surgery: Informatics, electronics, robotics. In: ...

  11. Nose Surgery

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  12. After Surgery

    Science.gov (United States)

    ... side effects. There is usually some pain with surgery. There may also be swelling and soreness around ... the first few days, weeks, or months after surgery. Some other questions to ask are How long ...

  13. Simulation

    DEFF Research Database (Denmark)

    Gould, Derek A; Chalmers, Nicholas; Johnson, Sheena J

    2012-01-01

    Recognition of the many limitations of traditional apprenticeship training is driving new approaches to learning medical procedural skills. Among simulation technologies and methods available today, computer-based systems are topical and bring the benefits of automated, repeatable, and reliable p...... performance assessments. Human factors research is central to simulator model development that is relevant to real-world imaging-guided interventional tasks and to the credentialing programs in which it would be used....

  14. Identifying position, visibility, dimensions, and angulation of the ear.

    Science.gov (United States)

    Mohamed, Kasim; Christian, Jayanth; Jeyapalan, Karthigeyan; Natarajan, Shanmuganathan; Banu, Fathima; Veeravalli, Padmanabhan T

    2014-01-01

    We selected 254 subjects between the ages of 18 and 30 yr to assess the ear position, angulations of the ear in relation to the nose, visibility from the frontal view, and dimensions of the ear by using various anthropometric points of the face. Subjects were divided into four groups based on facial form. A reference plane indicator, facial topographical measurements, metal ruler, and digital photography were used. While considering the position of the ear, in all facial forms except square tapering, the most samples showed a tendency for the subaurale being in line with subnasale. Regression analysis showed a tendency to gnathion distance is the most dependent variable with length of the ear kept as a constant predictor, while both interalar distance and exocanthion to endocanthion distance correlate highly significantly to the width of the ear. In all subjects, the visibility of the ear when viewed from the front was an average of 1.5 mm. Regardless of facial form, ear angulation was generally less than nose angulation.

  15. Ad Hoc Constitution of Topical Antibiotics Solution for Ear Dressing ...

    African Journals Online (AJOL)

    Background/ Purpose: In the management of chronic suppurative otitis media and otitis externa there are few cases where although an organism is cultured and isolated from the ear, there are either no antibiotic sensitive to the microbiological flora or the sensitive antibiotic is not available in the form of an ear drop, limiting ...

  16. Why do elephants flap their ears? | Wright | African Zoology

    African Journals Online (AJOL)

    The blood flow in the ear of the African elephant Loxodonta africana was measured In anaesthetized animals using the dye dilution technique at the same time as the arterio-venous temperature difference. The calculated heat loss from the ear is shown to be a substantial proportion of the total metabolic heat-loss ...

  17. Economic Evaluation pf Antibacterial Usage in Ear, Nose and Throat ...

    African Journals Online (AJOL)

    Purpose: To carry out economic evaluation of antibacterial usage for Ear, Nose and Throat infections in a tertiary health care facility in Nigeria. Methods: Antibacterial utilisation evaluation was carried out retrospectively over one year period by reviewing 122 case notes containing 182 prescriptions of patient with Ear Nose ...

  18. Congenital inner ear malformations without sensorineural hearing loss.

    Science.gov (United States)

    Yukawa, Kumiko; Horiguchi, Satoshi; Suzuki, Mamoru

    2008-03-01

    It has been reported that normal hearing is rare in patients with severe inner ear vestibular malformations [Kokai H, Oohashi M, Ishikawa K, Harada K, Hiratsuka H, Ogasawara M et al. Clinical review of inner ear malformation. J Otolaryngol Jpn 2003;106(10):1038-44; Schuknecht HF. Mondini dysplasia. A clinical pathological study. Ann Otol Rhinol Laryngol 1980;89(Suppl. 65):1-23; Jackler RK, Luxford WM, House WF. Congenital malformations of the inner ear: a classification based on embryogenesis. Laryngoscope 1987;97:2-14; Phelps PD. Congenital lesions of the inner ear, demonstrated by tomography. Arch Otolaryngol 1974;100:11-8]. A 37-year-old woman had combined dysplasia of the posterior and lateral semicircular canals (PSCC, LSCC) with normal cochlear development and normal hearing in both ears. She had complained of dizziness for 8 months. High resolution computed tomography (CT) showed hypogenesis of the bony labyrinth in both ears. Bilateral PSCC and LSCC dysplasia and dilatation of the vestibule were detected. Magnetic resonant imaging (MRI) revealed that the deformity of the PSCC was more severe than the LSCC. Although the caloric test of the left ear elicited no nystagmus and there was reduced response in the right ear, the horizontal vestibulo-occular reflex (VOR) was present. Her dizzy sensation disappeared within 3 months without special treatment. The dizziness attack might have been caused by a temporary breakdown of her peripheral vestibular system.

  19. Temporal bone CT analysis of congenital ear anomalies

    International Nuclear Information System (INIS)

    Hwang, Jung Won; Moon, Min Joo; Sung, Kyu Bo

    1988-01-01

    Authors analysed the CT findings of the congenital ear anomalies of twenty-nine patients for 2 years and 3 months. The results were as follows: 1. Most of the patients were under the age of 20 (82.7%) and prevalent in male (72.4%). 2. Clinically, congenital ear anomalies were detected in 20 patients (68.9%), conductive hearing loss in 4, sensorineural hearing loss in 1, and the remained 4 patients were detected incidentally without clinical symptom. 3. In the cases of unilateral involvement of 20 patients, right ear was more common (12/20). Eight of 9 bilateral involvement showed similar degree. 4. The middle ear malformations were found in 22 patients (75.9%) and bilateral in 4 patients. 26 cases of middle ear malformations had been classified by Frey into 4 groups; Group I in 5, Group II in 9, Graoup III in 9 and Group IV in 3. 5. Incidentally found ear anomaly was lateral semicircular canal formed a single cavity with the vestibule in all patients (5 pts.). 6. Inner ear malformations accompanying sensorineural hearing loss were found in 3 patients with bilateral involvement and middle ear malformations were accompanied in 2 patients. The degree of involvement of labyrinth was variable.

  20. The acoustical significance of age-dependent ear elongation

    DEFF Research Database (Denmark)

    Christensen, Flemming

    2015-01-01

    , corresponding to what is reported in the literature. For female ears, virtually no acoustical effect was found. For male ears directional dependent effects in the range up to 5 dB on average was found for certain directions and frequencies. Implications on age dependent hearing loss (presbycusis...

  1. Profile of Ear Diseases among Elderly Patients in Sagamu, South ...

    African Journals Online (AJOL)

    The importance of screening for hearing impairment in the elderly patients was also stressed. KEYWORDS: Cerumen, Ear disease, Elderly, Otitis, Presbycusis. Erratum Note: Olusola AS on the article “Profile of Ear Diseases among Elderly Patients in Sagamu, South-Western Nigeria” on Page Nig. J. Med 2013. 143-147.

  2. 14 CFR 67.205 - Ear, nose, throat, and equilibrium.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Ear, nose, throat, and equilibrium. 67.205..., nose, throat, and equilibrium. Ear, nose, throat, and equilibrium standards for a second-class airman..., vertigo or a disturbance of equilibrium. ...

  3. 14 CFR 67.105 - Ear, nose, throat, and equilibrium.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Ear, nose, throat, and equilibrium. 67.105..., nose, throat, and equilibrium. Ear, nose, throat, and equilibrium standards for a first-class airman... may reasonably be expected to be manifested by, vertigo or a disturbance of equilibrium. ...

  4. 14 CFR 67.305 - Ear, nose, throat, and equilibrium.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Ear, nose, throat, and equilibrium. 67.305..., nose, throat, and equilibrium. Ear, nose, throat, and equilibrium standards for a third-class airman... by, or that may reasonably be expected to be manifested by, vertigo or a disturbance of equilibrium. ...

  5. Directional characteristics for different in-ear recording points

    DEFF Research Database (Denmark)

    Møller, Anders Kalsgaard; Christensen, Flemming; Hoffmann, Pablo Faundez

    2015-01-01

    -back the sound. In this paper, measurements with different in-ear recording positions are conducted on nine subjects. The measurements are used for finding the optimal microphone position. The results show that spatial information equivalent to ears without insert earphones can be preserved up to around 4-5 kHz....

  6. Concha headphones and their coupling to the ear

    DEFF Research Database (Denmark)

    Blanchard, Lola Justine Kydia Olivia; Agerkvist, Finn T.

    2009-01-01

    The purpose of the study is to obtain a better understanding of concha headphone. Concha headphones are the small types of earpiece that are placed in the concha. They are not sealed to the ear and therefore, there is a leak between the earpiece and the ear. This leak is the reason why...

  7. 15 CFR 734.2 - Important EAR terms and principles.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Important EAR terms and principles. 734.2 Section 734.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade... OF THE EXPORT ADMINISTRATION REGULATIONS § 734.2 Important EAR terms and principles. (a) Subject to...

  8. Preventing Cauliflower Ear with a Modified Tie-Through Technique.

    Science.gov (United States)

    Dimeff, Robert J.; Hough, David O.

    1989-01-01

    Describes a quick, simple tie-through suture technique (in which a collodion packing is secured to the auricle with two buttons) for preventing cauliflower ear following external ear trauma in wrestlers and boxers. The technique ensures constant compression; multiple treatments for fluid reaccumulation are rarely necessary. (SM)

  9. Comparison of Microbiological Flora in the External Auditory Canal of Normal Ear and an Ear with Acute Otitis Externa.

    Science.gov (United States)

    Ghanpur, Asheesh Dora; Nayak, Dipak Ranjan; Chawla, Kiran; Shashidhar, V; Singh, Rohit

    2017-09-01

    Acute Otitis Externa (AOE) is also known as swimmer's ear. Investigations initiated during World War II firmly established the role of bacteria in the aetiology of Acute Otitis Externa. To culture the microbiological flora of the normal ear and compare it with the flora causing AOE and to know the role of normal ear canal flora and anaerobes in the aetiology. A prospective observational study was conducted on 64 patients clinically diagnosed with unilateral AOE. Ear swabs were taken from both the ears. Microbiological flora was studied considering diseased ear as test ear and the normal ear as the control. Aerobic and anaerobic cultures were done. Severity of the disease was assessed by subjective and objective scores. Effect of topical treatment with ichthammol glycerine pack was assessed after 48 hours and scores were calculated again. Patients with scores < 4 after pack removal were started on systemic antibiotics and were assessed after seven days of antibiotics course. Data was analysed using Paired t-test, Wilcoxon signed ranks test and Chi-square test. A p-value < 0.05 was considered significant. Pseudomonas aeruginosa (33%) was the most common bacteria cultured from the ear followed by Methicillin Resistant Staphylococcus aureus (MRSA) (18%). Patients with anaerobic organism in the test ear had severe symptoms and needed systemic antibiotic therapy. Most of the cases may respond to empirical antibiotic therapy. In cases with severe symptoms and the ones refractory to empirical treatment, a culture from the ear canal will not be a tax on the patient. This helps in giving a better understanding about the disease, causative organisms and helps in avoiding the use of inappropriate antibiotics that usually result in developing resistant strains of bacteria.

  10. Piezo-earpiece for micro-power generation from ear canal dynamic motion

    International Nuclear Information System (INIS)

    Delnavaz, Aidin; Voix, Jérémie

    2013-01-01

    This paper focuses on improving the past performance of ear canal energy harvesting by developing a piezo-earpiece prototype and a multiphysics finite element method to integrate more complex and effective piezoelectric structures. The proposed handmade piezo-earpiece prototype is a custom-moulded soft earpiece wrapped in a layer of flexible polyvinylidene fluoride. A finite element model is developed in order to estimate the energy harvesting capability of the piezoelectric layer. A prototype of the energy harvester is fabricated and tested. The experimental results show that the proposed device is able to generate 44 μJ of energy corresponding to an average value of 70 μW per jaw opening and closing cycle. Simulation of energy harvesting based on the finite element method is validated by the experimental results, thus confirming it as a versatile tool to model, optimize and evaluate the performance of other types of flexible piezoelectric structures for in-ear energy harvesting applications. (paper)

  11. Thyroid Surgery

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroid Surgery Resources Thyroid Surgery Brochure PDF Thyroid Surgery FAQs PDF En Español Cirugia De La Tiroides El folleto de Cirugia De La Tiroides Search Thyroid ...

  12. Magnetic resonance imaging in inflammatory lesions of the middle ear

    International Nuclear Information System (INIS)

    Tono, Tetsuya; Saku, Kazuaki; Miyanaga, Satoshi; Kano, Kiyo; Morimitsu, Tamotsu; Suzuki, Yukiko.

    1988-01-01

    Eighteen patients with chronic otitis media, middle ear cholesteatoma, and postoperative inflammatory diseases of the middle ear underwent high resolution computerized tomography (CT) and magnetic resonance imaging (MRI) before surgical exploration of the middle ear. Results showed that CT provides higher detail resolution in middle ear structures, but provides limited density resolution in displaying inflammatory soft tissue lesions. By contrast, MRI differentiates among soft tissue lesions such as fluid-filled spaces, granulation tissues, and cholesteatomatous debris. Cholesterin granulomas show a particularly characteristic signal pattern with a very high intensity area in both T1 and T2 weighted images. It is concluded that MRI is useful in differentiating soft tissue density masses when used in conjunction with CT in middle ear inflammatory diseases. (author)

  13. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...... in the transmission such as the earphone impedance. In order to determine the acoustic impedances of human ear canals, the standardized method for measurement of complex impedances used for the measurement of the audiometric earphone impedances is applied. It is based on the transfer function between two microphone...... locations in an impedance tube. The end of the tube representing the measurement plane is placed at the ear canal entrance. Thus, the impedance seen from the entrance inward is measured on 25 subjects. Most subjects participated in the previous measurement of the ratio between the pressures at the open...

  14. Anatomical variants of tympanic compartments and their aeration pathways involved in the pathogenesis of middle ear inflammatory disease

    Science.gov (United States)

    MANIU, ALMA; CATANA, IULIU V.; HARABAGIU, OANA; PETRI, MARIA; COSGAREA, MARCEL

    2013-01-01

    Aim The aim of this article is to review the anatomy of middle ear compartments and folds and to demonstrate through anatomical evidence their presence at birth. Additionally, their role in the obstructions of middle ear ventilatory pathway is highlighted. Methods Ninety-eight adult temporal bones, with no history of auricular disease and fifteen newborn temporal bones were studied by micro dissection. Documentation was done by color photography using the operation microscope Results Our micro-dissections have showed that mucosal folds from the middle ear are steadily present since birth, given that they were found in all newborn temporal bones. The mucosal folds in our normal adult material, showed some variations including membrane defects but they were constantly present. Our micro dissections showed that the epitympanic diaphragm consisted, in addition to malleal ligamental folds and ossicles, of only two constantly present folds: the tensor tympani fold and the incudomalleal fold. When the tensor fold is complete the only ventilation pathway to the anterior epitympanic space is through the isthmus, whereas its absence creates an efficient additional aeration route from the Eustachian tube to the epitympanum. Conclusions The goal of surgery in the chronic pathology of the middle ear should be restoration of normal ventilation of the attical-mastoid area. This is possible by removing the tensor fold and restoring the functionality of the isthmus tympani. PMID:26527977

  15. Question mark ears, temporo-mandibular joint malformation and hypotonia: auriculo-condylar syndrome or a distinct entity?

    Science.gov (United States)

    Priolo, M; Lerone, M; Rosaia, L; Calcagno, E P; Sadeghi, A K; Ghezzi, F; Ravazzolo, R; Silengo, M

    2000-10-01

    We report a boy with prominent, peculiarly malformed ears, abnormality of the ramus of the mandible and hypotonia. An isolated peculiar bilateral ear deformity named 'question mark ear' has been delineated in plastic reconstruction surgery reviews [Cosman et al., 1970 Plast Reconstr Surg 46:454-457; Cosman (1984) Plast Reconstr Surg 73:572-576; Takato et al. (1989) Ann Plast Surg 22:69-73; Brodovsky (1997) Plast Reconstr Surg 100:1254-1257; Park (1998) Plast Reconstr Surg 101:1620-1623; Al-Quattan (1998) Plast Reconstr Surg 102:439-441] and a similar deformity of the ear and changes in the temporo-mandibular joint and condyle has been described by Jampol et al. [(1998) Am J Med Genet 75:449-452] and by Guion-Almeida et al. [(1999) Am J Med Genet 86:130-133]. The present case may be the third description of this malformation complex with additional clinical features characterized by hypotonia and mild developmental delay, or possibly a new distinct entity.

  16. Physiological artifacts in scalp EEG and ear-EEG.

    Science.gov (United States)

    Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben

    2017-08-11

    A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.

  17. Mozart Ear Deformity: a Rare Diagnosis in the Ear Reconstruction Clinic.

    Science.gov (United States)

    Telich-Tarriba, Jose E; Victor-Baldin, Andre; Apellaniz-Campo, Armando

    2017-07-01

    Mozart ear is a rare auricular deformity; clinically the auricle is characterized by the bulging appearance of the anterosuperior portion of the auricle due to fusion of the crura of the antihelix, an inversion in the normal form of the cavum conchae resulting in its convexity and a slit-like narrowing of the orifice of the external auditory meatus.A retrospective review of clinical and photographic records of patients attended at the ear reconstruction clinic of our hospital between June of 2010 and May 2016 was performed; out of 576 consecutive patients only 3 fulfilled the inclusion criteria, with a prevalence of 0.5%. The authors present these patients.Surgical interventions mainly focus on the correction of the convex concha; however, the procedure should be tailored to the severity of the deformity and the wishes of the patient.

  18. [Risk factors for inner ear diseases].

    Science.gov (United States)

    Doroszewska, G; Kaźmierczak, H; Doroszewski, W

    2000-11-01

    The aim of this study was to evaluate the occurrence of obesity and arterial hypertension in patients suffering from vertigo, and/or tinnitus and/or hearing loss of unknown origin. 48 patients (25 women and 23 men) were included into this study. All patients had a negative previous medical history of any metabolic, cardiovascular or neurological disorders. Our results were compared to the control group of 31 healthy persons (16 women and 15 men). All subjects had a complete neurootologic examination, appropriate audiometric and vestibular studies. In most cases inner ear pathology was recognised. BMI, systolic and diastolic blood pressure were measured in all cases. Patients were overweight significantly more often comparing to the control group. Systolic and diastolic hypertension was found significantly more often in men from the patients than control group.

  19. Advances tomographic in evaluation of middle ear

    International Nuclear Information System (INIS)

    Anjos, Mayara Alves Pinheiro dos; Ledo, Mirelle D'arc Frota; Ribeiro, Marcio Duarte

    2011-01-01

    Computed tomography has a key role in the study of hearing, since through it can be evaluated structures not seen by otoscope. In many clinical situations the diagnosis through this test proves limited, being fundamental examination of the associated image reconstructions: multiplanar reconstruction, maximum intensity projection, and volume-rendering technique. The ossicular chain is a complex formed by the ossicles malleus, incus and stapes, situated in the middle ear; it is difficult to view them in orthogonals planes. This review article intends to demonstrate the importance of post-processing the image of the ossicular chain for a better representation of the anatomy and possible diseases. Reformatting of images helps, significantly, to a better visualization of these structures as related congenital malformations, vascular abnormalities, inflammatory conditions, neoplasia and traumas. (author)

  20. The effect of different sowing depths on fresh ear yield and some ear characteristics of sweet corn

    Directory of Open Access Journals (Sweden)

    Bekir Atar

    2017-12-01

    Full Text Available The research was conducted with aim to investigate effect on fresh ear yield and some ear characteristics of sweet corn of sowing at different depths during 2015 and 2016 years in Isparta. The experiments were set up according to randomized complete block design with three replicates using BATEM TATLI sweet corn cultivar. Furrows were opened at depths of 10 and 20 cm after the soil preparation, and seeds were sown in the 4-5 cm depth in to these furrows. According to means of years, while furrow sowing increased ear diameter, ear weigh, number of kernels per ear and fresh ear yield compared to control, it was not effect on ear length. In the research, between 10 cm and 20 cm furrow sowing wasn’t significant statistically. Fresh ear yield in control, 10 cm and 20 cm furrow sowing were measured as 1110.9 kg ha-1 , 1228.4 kg ha-1 and 1289.4 kg ha-1 , respectively. According to results of research, 5 cm deep sowing in 10 cm furrows should be advised in sweet corn cultivation.

  1. Presbycusis: do we have a third ear?

    Directory of Open Access Journals (Sweden)

    Luis Roque Reis

    Full Text Available Abstract Introduction: Age-related hearing changes are the most frequent cause of sensorineural hearing loss in adults. In the literature no studies exist concerning the importance of speechreading in individuals with presbycusis. Equally, no such studies have been carried out with speakers of the Portuguese (Portugal language. Objectives: To evaluate whether the intelligibility of words in presbycusis is improved by speechreading, in such a way that looking at the interlocutor's face while he is talking functions like a “third ear”, and to determine the statistical relevance of the intelligibility improvement by speechreading. Methods: Eleven individuals (22 ears with bilateral and symmetrical sensorineural hearing loss compatible with presbycusis were evaluated. The subjects were aged between 57 and 82 years, with an average of 70 ± 11.51 years and median of 69.5 years. A complete medical and audiological profile of each patient was created and all patients were submitted to a vocal audiogram, without and with observation of the audiologist's face. A descriptive and analytical statistical analysis was performed (Shapiro-Wilk and t pairs tests adopting the significance level of 0.05 (5%. Results: We noticed better performance in intelligibility with speechreading. The p-value was zero (p < 0.05, so we rejected the null hypothesis, showing that there was statistically significant difference with speechreading; the same conclusion was obtained by analysis of the confidence intervals. Conclusions: Individuals with presbycusis in this study, performed better on spoken word intelligibility when the hearing of those words was associated with speechreading. This phenomenon helps in such a way that observation of the interlocutor's face works like a "third ear".

  2. Innovations in robotic surgery.

    Science.gov (United States)

    Gettman, Matthew; Rivera, Marcelino

    2016-05-01

    Developments in robotic surgery have continued to advance care throughout the field of urology. The purpose of this review is to evaluate innovations in robotic surgery over the past 18 months. The release of the da Vinci Xi system heralded an improvement on the Si system with improved docking, the ability to further manipulate robotic arms without clashing, and an autofocus universal endoscope. Robotic simulation continues to evolve with improvements in simulation training design to include augmented reality in robotic surgical education. Robotic-assisted laparoendoscopic single-site surgery continues to evolve with improvements on technique that allow for tackling previously complex pathologic surgical anatomy including urologic oncology and reconstruction. Last, innovations of new surgical platforms with robotic systems to improve surgeon ergonomics and efficiency in ureteral and renal surgery are being applied in the clinical setting. Urologic surgery continues to be at the forefront of the revolution of robotic surgery with advancements in not only existing technology but also creation of entirely novel surgical systems.

  3. Simulation

    CERN Document Server

    Ross, Sheldon

    2006-01-01

    Ross's Simulation, Fourth Edition introduces aspiring and practicing actuaries, engineers, computer scientists and others to the practical aspects of constructing computerized simulation studies to analyze and interpret real phenomena. Readers learn to apply results of these analyses to problems in a wide variety of fields to obtain effective, accurate solutions and make predictions about future outcomes. This text explains how a computer can be used to generate random numbers, and how to use these random numbers to generate the behavior of a stochastic model over time. It presents the statist

  4. Passage of albumin from the middle ear to the inner ear in otitis media in the chinchilla

    International Nuclear Information System (INIS)

    Goldberg, B.; Goycoolea, M.V.; Schleivert, P.M.; Shea, D.; Schachern, P.; Paparella, M.M.; Carpenter, A.M.

    1981-01-01

    A study of the permeability of the middle ear-inner ear interface for macromolecules was carried out in chinchillas with open and obstructed eustachian tubes utilizing tritiated human serum albumin and immunoelectrophoresis. Tritiated albumin was placed in the round window niche area or normal animals and animals in which the eustachian tubes had been obstructed for 24 hours or 14 days. The tritiated albumin was allowed to remain in the middle ear cavity for 24 hours, Samples of middle ear effusion, perilymph, blood and cerebrospinal fluid were collected and measured for radioactivity. Radioactivity was demonstrated in the perilymph. Samples of middle ear effusions and perilymph were also studied by immunoelectrophoresis with goat antihuman albumin. Albumin placed in the round window niche of an experimental animal could be recovered unchanged in the perilymph. The results suggest a pathophysiologic explanation for the association of otitis media and sensorineural hearing loss or endolymphatic hydrops

  5. [The history of pediatric plastic surgery].

    Science.gov (United States)

    Glicenstein, J

    2016-10-01

    The history of pediatric plastic surgery is linked to that of paediatrics. Until the early 19th century, there was no children's hospital. Only some operations were performed before the discovery of anesthesia, aseptic and antisepsis: cleft lip repair, amputation for polydactyly. Many operations were described in the 19th century for cleft lip and palate repair, hypospadias, syndactylies. The first operation for protruding ears was performed in 1881. Pediatric plastic surgery is diversified in the 2nd half of the 20th century: cleft lip and palate, burns, craniofacial surgery, hand surgery become separate parts of the speciality. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. A DESCRIPTIVE STUDY OF FUNGAL INFECTIONS IN CHRONICALLY DISCHARGING EARS

    Directory of Open Access Journals (Sweden)

    Sujatha

    2015-08-01

    Full Text Available BACKGROUND : Chronic Suppurative Otitis Media (CSOM is a disease of multiple aetiology and well known for its persis tence and recurrence inspite of treatment and are the bearbug of otologist, paediatrician and general practitioner. One of the reason s for the refractoriness to treatment and chronicity is coexist ing fungal infection of the ear. OBJECTIVES: Are to find out the prevalence of fungal infections in chronic discharging ears and to identify and isolate the type of fungus prevalent in these ears . MATERIALS AND METHOD S: Tertiary care hospital level descrip tive study was conducted in 50 cases of CSOM with actively discharging ears for a period of one year starting from February 2013. For all the cases aural swabs were collected from the diseased ear and were used for direct microscopic examination in potassi um hydroxide wet mount. Ear swab was cultured on Sabouraud’s dextrose agar plate for fungal cultures. The patient characteristics were prospectively recorded and results were analysed. CONCLUSION : There is high prevalence of coexisting fungal infection in actively discharging ears of CSOM patients

  7. An in vitro model of murine middle ear epithelium.

    Science.gov (United States)

    Mulay, Apoorva; Akram, Khondoker M; Williams, Debbie; Armes, Hannah; Russell, Catherine; Hood, Derek; Armstrong, Stuart; Stewart, James P; Brown, Steve D M; Bingle, Lynne; Bingle, Colin D

    2016-11-01

    Otitis media (OM), or middle ear inflammation, is the most common paediatric disease and leads to significant morbidity. Although understanding of underlying disease mechanisms is hampered by complex pathophysiology it is clear that epithelial abnormalities underpin the disease. There is currently a lack of a well-characterised in vitro model of the middle ear (ME) epithelium that replicates the complex cellular composition of the middle ear. Here, we report the development of a novel in vitro model of mouse middle ear epithelial cells (mMECs) at an air-liquid interface (ALI) that recapitulates the characteristics of the native murine ME epithelium. We demonstrate that mMECs undergo differentiation into the varied cell populations seen within the native middle ear. Proteomic analysis confirmed that the cultures secrete a multitude of innate defence proteins from their apical surface. We showed that the mMECs supported the growth of the otopathogen, nontypeable Haemophilus influenzae (NTHi), suggesting that the model can be successfully utilised to study host-pathogen interactions in the middle ear. Overall, our mMEC culture system can help to better understand the cell biology of the middle ear and improve our understanding of the pathophysiology of OM. The model also has the potential to serve as a platform for validation of treatments designed to reverse aspects of epithelial remodelling that underpin OM development. © 2016. Published by The Company of Biologists Ltd.

  8. THE IDENTIFICATION OF EAR PRINTS USING COMPLEX GABOR FILTERS

    Directory of Open Access Journals (Sweden)

    Alexander A S Gunawan

    2012-05-01

    Full Text Available Biometrics is a method used to recognize humans based on one or a few characteristicsphysical or behavioral traits that are unique such as DNA, face, fingerprints, gait, iris, palm, retina,signature and sound. Although the facts that ear prints are found in 15% of crime scenes, ear printsresearch has been very limited since the success of fingerprints modality. The advantage of the useof ear prints, as forensic evidence, are it relatively unchanged due to increased age and have fewervariations than faces with expression variation and orientation. In this research, complex Gaborfilters is used to extract the ear prints feature based on texture segmentation. Principal componentanalysis (PCA is then used for dimensionality-reduction where variation in the dataset ispreserved. The classification is done in a lower dimension space defined by principal componentsbased on Euclidean distance. In experiments, it is used left and right ear prints of ten respondentsand in average, the successful recognition rate is 78%. Based on the experiment results, it isconcluded that ear prints is suitable as forensic evidence mainly when combined with otherbiometric modalities.Keywords: Biometrics; Ear prints; Complex Gabor filters; Principal component analysis;Euclidean distance

  9. An in vitro model of murine middle ear epithelium

    Directory of Open Access Journals (Sweden)

    Apoorva Mulay

    2016-11-01

    Full Text Available Otitis media (OM, or middle ear inflammation, is the most common paediatric disease and leads to significant morbidity. Although understanding of underlying disease mechanisms is hampered by complex pathophysiology it is clear that epithelial abnormalities underpin the disease. There is currently a lack of a well-characterised in vitro model of the middle ear (ME epithelium that replicates the complex cellular composition of the middle ear. Here, we report the development of a novel in vitro model of mouse middle ear epithelial cells (mMECs at an air–liquid interface (ALI that recapitulates the characteristics of the native murine ME epithelium. We demonstrate that mMECs undergo differentiation into the varied cell populations seen within the native middle ear. Proteomic analysis confirmed that the cultures secrete a multitude of innate defence proteins from their apical surface. We showed that the mMECs supported the growth of the otopathogen, nontypeable Haemophilus influenzae (NTHi, suggesting that the model can be successfully utilised to study host–pathogen interactions in the middle ear. Overall, our mMEC culture system can help to better understand the cell biology of the middle ear and improve our understanding of the pathophysiology of OM. The model also has the potential to serve as a platform for validation of treatments designed to reverse aspects of epithelial remodelling that underpin OM development.

  10. Virtual reality and laparoscopic surgery.

    Science.gov (United States)

    Coleman, J; Nduka, C C; Darzi, A

    1994-12-01

    The nature of laparoscopic surgery makes it likely to benefit from current and future developments in virtual reality and telepresence technology. High-definition screens, three-dimensional sensory feedback and remote dextrous manipulation will be the next major developments in laparoscopic surgery. Simulators may be used in surgical training and in the evaluation of surgical capability.

  11. Simulation Training in Hysteroscopic Surgery

    OpenAIRE

    Janse, J.A.

    2014-01-01

    Hysteroscopy detects uterine cavity pathology by direct visualisation of the endometrial lining, making use of a vaginally inserted endoscope. The additional insertion of an instrument through the endoscope provides the opportunity for obtainment of histology and treatment of pathologies, and for sterilisation of women. It is therefore an essential diagnostic and therapeutic tool in the current practice of gynaecology. Even though hysteroscopic skills are often perceived to be less complicate...

  12. Simulation Training in Hysteroscopic Surgery

    NARCIS (Netherlands)

    Janse, J.A.

    2014-01-01

    Hysteroscopy detects uterine cavity pathology by direct visualisation of the endometrial lining, making use of a vaginally inserted endoscope. The additional insertion of an instrument through the endoscope provides the opportunity for obtainment of histology and treatment of pathologies, and for

  13. Trends and complications of ear piercing among selected Nigerian population

    Directory of Open Access Journals (Sweden)

    Olajide Toye Gabriel

    2017-01-01

    Full Text Available Background: The reported health and socioeconomic consequences of ear piercing, especially in modern day society, underscore the need to further research into this subject. In this study, we determine the trends and complications of ear piercing among selected Nigerian population. Aim and Objectives: The aim and objective of this study was to draw attention to the trends and complications of ear piercing with a view to prevent its associated complications. Methodology: It is a descriptive cross-sectional study carried out between February and May 2015 among selected Nigerian population from two of its six geo-political zones. A self-administered semi-structured questionnaire which had been pretested was used to collect data from 458 respondents who consented using multistage sampling technique. Results: Of 480 respondents enumerated, 458 completed the questionnaires and gave their biodata. The male:female ratio was 1:6.2. Their ages ranged from 18 to 75 years with a mean of 35.56 ± 10.16. About 35.4% of the respondents were within the age group of 31–40 years. Majority of the respondents, i.e.,79.3% practiced ear piercing on their children. Most of them (86.8% preferred single piercing. Ear piercing was performed within the 1st week of birth in 37.2% of the respondents. Large percentage (93.2% of the respondents will not encourage ear piercing in male children. Nearly 20.5% of the respondents observed complications. Conclusion: Ear piercing remained a common practice in Nigeria, with respondents preferring it on females. Majority of the piercings are done in childhood and by untrained personnel. Keloid formation was the notable complication observed by the respondents. There is a need to increase awareness about the hazards of ear piercings and to enact laws that regulate ear piercings particularly in children which is hereby stretched.

  14. 3D ear identification based on sparse representation.

    Directory of Open Access Journals (Sweden)

    Lin Zhang

    Full Text Available Biometrics based personal authentication is an effective way for automatically recognizing, with a high confidence, a person's identity. Recently, 3D ear shape has attracted tremendous interests in research field due to its richness of feature and ease of acquisition. However, the existing ICP (Iterative Closet Point-based 3D ear matching methods prevalent in the literature are not quite efficient to cope with the one-to-many identification case. In this paper, we aim to fill this gap by proposing a novel effective fully automatic 3D ear identification system. We at first propose an accurate and efficient template-based ear detection method. By utilizing such a method, the extracted ear regions are represented in a common canonical coordinate system determined by the ear contour template, which facilitates much the following stages of feature extraction and classification. For each extracted 3D ear, a feature vector is generated as its representation by making use of a PCA-based local feature descriptor. At the stage of classification, we resort to the sparse representation based classification approach, which actually solves an l1-minimization problem. To the best of our knowledge, this is the first work introducing the sparse representation framework into the field of 3D ear identification. Extensive experiments conducted on a benchmark dataset corroborate the effectiveness and efficiency of the proposed approach. The associated Matlab source code and the evaluation results have been made publicly online available at http://sse.tongji.edu.cn/linzhang/ear/srcear/srcear.htm.

  15. All for knots: evaluating the effectiveness of a proficiency-driven, simulation-based knot tying and suturing curriculum for medical students during their third-year surgery clerkship.

    Science.gov (United States)

    Pender, Cianna; Kiselov, Vladimir; Yu, Qingzhao; Mooney, Jennifer; Greiffenstein, Patrick; Paige, John T

    2017-02-01

    We evaluated the effectiveness of implementing a proficiency-driven, simulation-based knot tying and suturing curriculum for medical students during their 3rd-year surgery clerkship. Medical students on the 3rd-year surgical clerkship completed a proficiency-driven, simulation-based knot tying and suturing curriculum consisting of 6 tasks. The effectiveness was evaluated by comparing the initial presession scores to the final postsession scores on an 8-item self-efficacy scale and evaluating pass rates on end of clerkship skills testing. A paired t test was used to analyze data. Sixty-five students had matched preintervention and postintervention questionnaires for analysis. Pass rates approached 100% by the 3rd attempt on all tasks. Significant gains on all 8 items of the self-efficacy questionnaire from pretraining to post-training were noted. Timing of the general surgery rotation did not impact results. Implementation of a simulation-based training, proficiency-driven knot tying and suturing curriculum for 3rd-year medical students during the surgery clerkship is feasible and effective in improving student self-efficacy and objective proficiency toward performance of the tasks taught. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Tissue Expansion Using Hyaluronic Acid Filler for Single-Stage Ear Reconstruction: A Novel Concept for Difficult Areas.

    Science.gov (United States)

    Inbal, Amir; Lemelman, Benjamin T; Millet, Eran; Greensmith, Andrew

    2017-10-16

    Auricular reconstruction is one of the most challenging procedures in plastic surgery. An adequate skin envelope is essential for cartilage framework coverage, yet few good options exist without additional surgery. We propose a novel method for minimally invasive tissue expansion, using hyaluronic acid (HA) filler to allow for single-stage ear reconstruction. To introduce the novel concept of HA filler for tissue expansion in ear reconstruction, and as an alternative to traditional expansion techniques. Macrolane is a large particle HA gel developed for large volume restoration. Expansion of the non-hair-bearing mastoid skin was performed in our clinic weekly or every other week. Final expansion was completed one week prior to reconstructive surgery. Tissue from one patient's expanded pocket was sent for histological analysis. Ten patients underwent single-stage auricular reconstruction with preoperative expansion. Injection sessions ranged from 7 to 13 (mean, 9.7). Mean injected volume per session was 2.03 mL per patient, for an average total of 19.8 mL (range, 14.5-30 mL). There were no major complications. One minor complication required removal of exposed wire from the antihelix in the office. Hematoxylin and eosin stain revealed similar histology to that seen with traditional expanders. This novel expansion technique using serial HA injections allowed for optimized skin coverage in single-stage ear reconstruction. The concept of tissue expansion using HA filler is a new frontier for research that may be applicable to other arenas of reconstruction. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  17. The middle ear immune defense changes with age

    DEFF Research Database (Denmark)

    Nielsen, Michelle Christine; Friis, Morten; Martin-Bertelsen, Tomas

    2016-01-01

    of this study was to analyze the relationship between age and the mucosal immune system in the middle ear. It is hypothesized that genes involved in the middle ear immune system will change with age. A comprehensive assessment of these genetic differences using the techniques of complementary DNA has not been...... performed. Complementary DNA microarray technology was used to identify immune-related genes differentially expressed between the normal middle ear mucosa of young (10 days old) and adult rats (80 days old). Data were analyzed using tools of bioinformatics. A total of 260 age-related genes were identified...

  18. Neonatal Hairy Ear Pinnae and Gestational Diabetes: Just a Coincidence?

    Science.gov (United States)

    Valerio, Enrico; Riello, Laura; Chirico, Michela; Semenzato, Rossella; Cutrone, Mario

    2015-01-01

    A newborn girl of 36 weeks gestation was noted to have several anomalies, including bilateral low ear attachment with ear pinnae hypertrichosis, left preauricular pit, micrognathia, short lingual frenulum, and short neck. Pregnancy history revealed poorly controlled maternal gestational diabetes (GD). Localized hypertrichosis of the ear pinnae may represent a potential marker of GD and thereby alert physicians to suspect other potentially GD-associated conditions such as macrosomia, asphyxia, respiratory distress, hypoglycemia, hypocalcemia, hyperbilirubinemia, polycythemia, hypertrophic cardiomyopathy, and congenital anomalies, particularly those involving the central nervous system. © 2015 Wiley Periodicals, Inc.

  19. Electrode Impedance Fluctuations as a Biomarker for Inner Ear Pathology After Cochlear Implantation.

    Science.gov (United States)

    Choi, June; Payne, Matthew R; Campbell, Luke J; Bester, Christo W; Newbold, Carrie; Eastwood, Hayden; O'Leary, Stephen J

    2017-12-01

    Cochlear implant surgery now aims to preserve residual low frequency hearing. The current research explores whether fluctuations in the electrical impedance of cochlear implant electrodes may act as a biomarker for pathological changes that lead to the delayed loss of residual hearing. Secondary analysis of a double-blinded randomized trial, where methylprednisolone was administered intravenously before cochlear implantation with a view to preserving residual hearing. Seventy-four patients with residual hearing after cochlear implant surgery were investigated for an impedance "spike," defined as a median rise of ≥4 kΩ across all electrodes from the baseline measurements. Spikes were related to objective and subjective hearing loss, dizziness, and tinnitus. An impedance spike occurred in 14% (10/74) of enrolled patients. Three months after surgery, five patients exhibited spikes and three of these patients had a total loss of their residual hearing. 4.3% of the 69 patients without spikes lost residual hearing. At 1 year, 9 of 10 patients who exhibited spikes had lost all their residual hearing. 8.1% of the 37 patients who did not experience a spike lost their residual hearing. Seventy percent of patients exhibiting a spike also experienced vertigo. The administration of steroids at the time of surgery did not influence the occurrence of spikes. Our results suggest that there is a relationship between a spike and the loss of residual hearing. It seems that rises in impedance can reflect pathology within the inner ear and predict the future loss of residual hearing.

  20. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Mondel, Prabath Kumar, E-mail: prabathmondel@gmail.com; Anand, Sunanda, E-mail: sunandaanand@gmail.com; Limaye, Uday S., E-mail: uslkem@gmail.com [Lilavati Hospital and Research Centre, Department of Interventional Neuroradiology (India)

    2015-08-15

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described.

  1. Crouzon’s Syndrome with Life-Threatening Ear Bleed: Ruptured Jugular Vein Diverticulum Treated by Endovascular Embolization

    International Nuclear Information System (INIS)

    Mondel, Prabath Kumar; Anand, Sunanda; Limaye, Uday S.

    2015-01-01

    Crouzon’s syndrome is the commonest variety of syndromic craniosynostosis. Life-threatening ear bleed due to ruptured jugular venous diverticulum in Crouzon’s syndrome has not been described previously. In patients with syndromic craniosynostosis, definitive repair of jugular diverticulum by open surgery is fraught with high risk of bleeding, poor functional outcomes, and even death. A 24-year-old woman with Crouzon’s syndrome presented with conductive hearing loss and recurrent episodes of torrential bleeding from her left ear. On computed tomography, a defect in the roof of jugular fossa containing jugular venous diverticulum immediately inferior to the bony external auditory canal was seen. The clinical presentation, imaging features, and endovascular management of Crouzon’s syndrome due to a ruptured jugular venous diverticulum is described

  2. Otolaryngology fantastica: the ear, nose, and throat manifestations of Munchausen's syndrome.

    Science.gov (United States)

    Alicandri-Ciufelli, Matteo; Moretti, Valentina; Ruberto, Marco; Monzani, Daniele; Chiarini, Luigi; Presutti, Livio

    2012-01-01

    Munchausen's syndrome (MS) is a form of severe, chronic, factitious disorder with physical symptoms. Some essential features define MS, such as recurrent, feigned, or simulated illness; peregrination (traveling or wandering); pseudologia fantastica; and drug abuse. Munchausen's syndrome by proxy (MSBP) classically involves a parent or other caregiver who inflicts injury or induces illness in a child. The aim of the present study was to summarize and study the main ear, nose, and throat (ENT) manifestations of MS and MSBP. A systematic literature review carried out in a tertiary university referral center. An appropriate string was run on PubMed to retrieve articles dealing with ENT manifestations of MS and MSBP. A double cross-check was performed on citations and full-text articles found using selected inclusion and exclusion criteria. In total, 24 articles were finally included in the study, describing 30 cases of MS or MSBP involving the ENT region; 15/30 (50%) cases involved the face, most often presenting as facial pain or facial swelling; and 7/30 (23.3%) cases presented with symptoms involving the ear. Six cases out of 30 (20%) were MSBP. MS and MSBP may present with symptoms involving the head and neck area, particularly the face and external ear canal. The ENT specialist should suspect MS in patients with strange and long-lasting symptoms, so as to avoid misdiagnosis and unnecessary treatments that waste time and money in the healthcare sector. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  3. Prognostic value of bone involvement in patients with squamous cell carcinoma of the external and middle ear

    International Nuclear Information System (INIS)

    Shiga, Hideaki; Ito, Makoto; Uramoto, Naoki; Hatano, Miyako; Miwa, Takaki; Furukawa, Mitsuru

    2007-01-01

    The incidence of the external and middle ear squamous cell carcinoma (SCC) is extremely rare in the head and neck cancer with less than 1%. Therefore, the correlation between the staging classification and the prognosis has not been clear. Prognostic factors for patients with the external and middle ear SCC were assessed in the initial clinical symptoms and radiographic imaging. 13 patients with the external and middle ear SCC (5 male and 8 female) that had been treated at the Department of Otorhinolaryngology, Kanazawa University hospital from 2000 to 2006 were selected for this study. The radiation therapy followed surgery in ten patients. One patient received the radical cure irradiation before surgery. Two patients received a surgical excision alone. The temporal bone involvement and the parotid gland involvement in the radiographic image (computed tomography imaging and/or magnetic resonance imaging) were assessed. Clinical symptoms (otalgia, hearing disturbance, tinnitus, vertigo and facial nerve palsy) before treatment were reviewed based on the medical record. The correlation of those clinical factors and T staging in the Pittsburgh classification with overall survival was statistically assessed. The temporal bone involvement significantly correlated with worse prognosis. However, parotid gland involvement did not influence the prognosis. Moreover, statistically significant difference in T staging of the Pittsburgh classification (T1·T2 vs. T3·T4) was not found. The temporal bone involvement in the radiographic image was a prognostic factor for patients with the external and middle ear SCC. Pittsburgh classification needs to be modified because the bony part of the external auditory canal involvement is considered as T2 stage and the soft tissue involvement is defined as T4 stage. (author)

  4. Prognostic value of bone involvement in patients with squamous cell carcinoma of the external and middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Shiga, Hideaki; Ito, Makoto; Uramoto, Naoki; Hatano, Miyako; Miwa, Takaki; Furukawa, Mitsuru [Kanazawa Univ., Graduate School of Medical Science, Kanazawa, Ishikawa (Japan)

    2007-05-15

    The incidence of the external and middle ear squamous cell carcinoma (SCC) is extremely rare in the head and neck cancer with less than 1%. Therefore, the correlation between the staging classification and the prognosis has not been clear. Prognostic factors for patients with the external and middle ear SCC were assessed in the initial clinical symptoms and radiographic imaging. 13 patients with the external and middle ear SCC (5 male and 8 female) that had been treated at the Department of Otorhinolaryngology, Kanazawa University hospital from 2000 to 2006 were selected for this study. The radiation therapy followed surgery in ten patients. One patient received the radical cure irradiation before surgery. Two patients received a surgical excision alone. The temporal bone involvement and the parotid gland involvement in the radiographic image (computed tomography imaging and/or magnetic resonance imaging) were assessed. Clinical symptoms (otalgia, hearing disturbance, tinnitus, vertigo and facial nerve palsy) before treatment were reviewed based on the medical record. The correlation of those clinical factors and T staging in the Pittsburgh classification with overall survival was statistically assessed. The temporal bone involvement significantly correlated with worse prognosis. However, parotid gland involvement did not influence the prognosis. Moreover, statistically significant difference in T staging of the Pittsburgh classification (T1{center_dot}T2 vs. T3{center_dot}T4) was not found. The temporal bone involvement in the radiographic image was a prognostic factor for patients with the external and middle ear SCC. Pittsburgh classification needs to be modified because the bony part of the external auditory canal involvement is considered as T2 stage and the soft tissue involvement is defined as T4 stage. (author)

  5. Evolution of the excess absolute risk (EAR) in the Valencian breast cancer screening programme

    International Nuclear Information System (INIS)

    Ferrer, S.; Ramos, M.; Villaescusa, J. I.; Verdu, G.; Salas, M. D.; Cuevas, M. D.

    2004-01-01

    Breast cancer is one of the most frequent diseases in women, with a high incidence rate. The best fight against the breast cancer is the early detection by menas of mammograms in a screening programme. The Valencian Breast Cancer Screening Programme (VBCSP) started at 1992, and it is composed of twenty-two mammography units. The programme is targeted towards asympotomatic women dfrom 45 to 69 years old, but this screening has a negative influence in the studied woman, whatever the diagnosis was. By means of MCNP-4c2 Monte Carlo code, some conversion factors from air kerma air kerma to glandular dose have been developed. Different breast woamn models, according to the Valencian brest anathomy (taking into account the relation breast radius / breast compression thickness obtained from real samples, have been simulated in order to obtain the glandular breast dose values. Quality control parameters as ESAK values were also employed for developing the methods. The conversion factors give a simple and fast wasy to obtain the mean glandular dose from mammography exposition parameters. The glandular dose has been also calculated following the European Protocol on Dosimetry in order to compare the results of the new methodology. Four sample populations of 100 omen from each uunit of the VBCSP have been taken innnn order to estimate the mean glandular dose and the associated excess absolute risk (EAR). Once the doses for each woman from the samples are obtained and according to the age of them, the EAR value for each sample has been determinated following the UNSCEAR 2000 projection risk model, which takes into account the characteristics of the Valencian population and gives the EAR for radio-induced breast cancer. The results have been calculated and compared by means of the ASQRAD software, but with an older risk projection model, the UNSCEAR 1994. Once the four sample average EAR have been calculated, the evolution of the induced risk in the Valencian Breast Cancer

  6. Advances in otolaryngology-Head and neck surgery. Volume 1

    International Nuclear Information System (INIS)

    Myers, E.N.; Bluestone, C.D.

    1987-01-01

    This book consists of 14 sections. The section titles are: The impact of AIDS on otolaryngology--head and neck surgery; The management of sleep apneas and snoring; Antimicrobial agents for infections in the ear, nose, and throat--head and neck; Nasal allergy: Medical and surgical treatment; Uses of computerized tomography and magnetic resonance imaging in temporal bone imaging; Surgical management of otitis media with effusion; middle ear reconstruction: Current status; Cochlear implants: an overview; Diagnosis and management of acute facial paralysis; The use of the laser in head and neck surgery; The management and prevention of subglottic stenosis in infants and children; Management of the mass in the thyroid; Suction-assisted lipectomy of the head and neck area; and Ambulatory surgery

  7. Advances in otolaryngology-Head and neck surgery. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Myers, E.N. (Univ. of Pittsburgh School of Medicine, Pittsburgh, PA (US)); Bluestone, C.D. (Univ. of Pittsburgh, Pittsburgh, PA (US))

    1987-01-01

    This book consists of 14 sections. The section titles are: The impact of AIDS on otolaryngology--head and neck surgery; The management of sleep apneas and snoring; Antimicrobial agents for infections in the ear, nose, and throat--head and neck; Nasal allergy: Medical and surgical treatment; Uses of computerized tomography and magnetic resonance imaging in temporal bone imaging; Surgical management of otitis media with effusion; middle ear reconstruction: Current status; Cochlear implants: an overview; Diagnosis and management of acute facial paralysis; The use of the laser in head and neck surgery; The management and prevention of subglottic stenosis in infants and children; Management of the mass in the thyroid; Suction-assisted lipectomy of the head and neck area; and Ambulatory surgery.

  8. Laser vibrometer measurements and middle ear prostheses

    Science.gov (United States)

    Flock, Stephen T.; Dornhoffer, John; Ferguson, Scott

    1997-05-01

    One of us has developed an improved partial ossicular replacement prosthesis that is easier to implant and, based on pilot clinical measurements, results in better high-frequency hearing as compared to patients receiving one of the alternative prostheses. It is hypothesized that the primary reason for this is because of the relatively light weight (about 25 mg) and low compliance of the prosthesis, which could conceivably result in better high frequency vibrational characteristics. The purpose of our initial work was to develop an instrument suitable for objectively testing the vibrational characteristics of prostheses. We have developed a laser based device suitable for measuring the vibrational characteristics of the oval window or other structures of the middle ear. We have tested this device using a piezoelectric transducer excited at audio frequencies, as well as on the oval window in human temporal bones harvested from cadavers. The results illustrate that it is possible to non-invasively monitor the vibrational characteristics of anatomic structures with a very inexpensive photonic device.

  9. Gentamicin pharmacokinetics in the chicken inner ear.

    Science.gov (United States)

    Bunting, Eric C; Park, Debra L; Durham, Dianne; Girod, Douglas A

    2004-06-01

    Avians have the unique ability to regenerate cochlear hair cells that are lost due to ototoxins or excessive noise. Many methodological techniques are available to damage the hair cells for subsequent scientific study. A recent method utilizes topical application of an ototoxic drug to the round window membrane. The current study examines the pharmacokinetics of gentamicin in the inner ear of chickens following topical application to the round window membrane or a single systemic high dose given intraperitoneally. Chickens were given gentamicin topically or systemically and survived for 1, 4, 12, 24, or 120 h (controls at 4 and 120 h). Serum and perilymph samples were obtained prior to sacrifice and measured for gentamicin levels. Results revealed higher levels of gentamicin in the perilymph of topically treated chickens than systemically treated chickens, with significant amounts of gentamicin still present in both at the latest survival time of 5 days. As expected, systemically treated chickens had much higher levels of gentamicin in the serum than topically treated chickens. Advantages and disadvantages to each method of drug administration are discussed.

  10. The acoustic reflex threshold in aging ears.

    Science.gov (United States)

    Silverman, C A; Silman, S; Miller, M H

    1983-01-01

    This study investigates the controversy regarding the influence of age on the acoustic reflex threshold for broadband noise, 500-, 1000-, 2000-, and 4000-Hz activators between Jerger et al. [Mono. Contemp. Audiol. 1 (1978)] and Jerger [J. Acoust. Soc. Am. 66 (1979)] on the one hand and Silman [J. Acoust. Soc. Am. 66 (1979)] and others on the other. The acoustic reflex thresholds for broadband noise, 500-, 1000-, 2000-, and 4000-Hz activators were evaluated under two measurement conditions. Seventy-two normal-hearing ears were drawn from 72 subjects ranging in age from 20-69 years. The results revealed that age was correlated with the acoustic reflex threshold for BBN activator but not for any of the tonal activators; the correlation was stronger under the 1-dB than under the 5-dB measurement condition. Also, the mean acoustic reflex thresholds for broadband noise activator were essentially similar to those reported by Jerger et al. (1978) but differed from those obtained in this study under the 1-dB measurement condition.

  11. How minute sooglossid frogs hear without a middle ear.

    Science.gov (United States)

    Boistel, Renaud; Aubin, Thierry; Cloetens, Peter; Peyrin, Françoise; Scotti, Thierry; Herzog, Philippe; Gerlach, Justin; Pollet, Nicolas; Aubry, Jean-François

    2013-09-17

    Acoustic communication is widespread in animals. According to the sensory drive hypothesis [Endler JA (1993) Philos Trans R Soc Lond B Biol Sci 340(1292):215-225], communication signals and perceptual systems have coevolved. A clear illustration of this is the evolution of the tetrapod middle ear, adapted to life on land. Here we report the discovery of a bone conduction-mediated stimulation of the ear by wave propagation in Sechellophryne gardineri, one of the world's smallest terrestrial tetrapods, which lacks a middle ear yet produces acoustic signals. Based on X-ray synchrotron holotomography, we measured the biomechanical properties of the otic tissues and modeled the acoustic propagation. Our models show how bone conduction enhanced by the resonating role of the mouth allows these seemingly deaf frogs to communicate effectively without a middle ear.

  12. Congenital malformations of the external and middle ear

    International Nuclear Information System (INIS)

    Koesling, S.; Omenzetter, M.; Bartel-Friedrich, S.

    2009-01-01

    With the focus on imaging, this paper gives a summarized view of the present knowledge on fields, which are necessary to know for a profound understanding of congenital malformations of the external and middle ear. Typical and less typical combinations of malformed parts of the ear can be derived from the embryogenesis. Clinical signs and audiometric findings lead to diagnosis in congenital aural atresia. Isolated middle ear malformations can be clinically mixed up especially with otosclerosis and tympanosclerosis. Imaging is needed for exact morphological information. In malformations of the external and middle ear, CT is the imaging modality of choice. Requirements on CT-technique as well as radiological findings including classification and pre-surgical rating are described. Morphological CT-correlates of congenital malformations and their differential diagnoses are enlisted and illustrated. The impact of CT-results on therapy is explained and actual therapeutic concepts are briefly presented

  13. The ferret as a model for inner ear research.

    Science.gov (United States)

    Rarey, K E

    1985-06-01

    Viral infections have long been suspected to be causative agents in a number of inner ear dysfunctions. With few exceptions, the virus has not been demonstrated as the direct agent leading to hearing loss and/or vertigo. Selective inner ear changes have been observed recently in sensory and nonsensory epithelial cells in the ferret model for Reye's syndrome after intranasal inoculation with influenza B combined with aspirin administration and the creation of an arginine deficiency. Such findings suggest that these agents act synergistically on the inner ear, particularly on cells that are metabolically active, and that the ferret may now be a useful model to examine the role of certain upper respiratory tract viruses implicated in inner ear disorders, singly and in combination with other agents that may cause metabolic alterations.

  14. [Reconstruction of the ear in the burns patient].

    Science.gov (United States)

    Carrillo-Córdova, Jorge Raúl; Jiménez Murat, Yusef; Apellaniz-Campo, Armando; Bracho-Olvera, Hazel; Carrillo Esper, Raúl

    Face burns are a singular pathology with great functional and psychological impact in the patients suffering them. The ears play a fundamental role in personal interactions and damage to this organ results in physical and emotional distress. The reconstructive treatment of the burned ear is a challenge. Multiple procedures have been described to achieve success in the reconstruction of the burned ear; immediate reconstruction with autologous rib cartilage, secondary reconstruction, alloplastic material reconstruction, tissue expansion, skin grafts and also microvascular flaps are some of the most common procedures used in this patients. All these techniques focus on giving a natural appearance to the patient. Burns to the ears affect 30% of the patients with facial burns, they require an excellent treatment given by a multidisciplinary team. Copyright © 2017 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  15. Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    Mucize Eriç Özdemir

    2014-12-01

    Full Text Available Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm = y = (1.348 X gestational age-12.265, where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001. Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements.

  16. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ...

  17. Study on corrosion products from ear piercing studs

    International Nuclear Information System (INIS)

    Rogero, Sizue O.; Costa, Isolda; Saiki, Mitiko

    2000-01-01

    In this work instrumental neutron activation analysis was applied to analyse elemental composition of commercial gold coated ear piercing substrate and metals present in their corrosion products. The cytotoxic effect was also verified in these corrosion product extracts, probably, due to the lixiviation of Ni present in high quantity in their substrates. The analysis of gold coated ear piercing surfaces by scanning electron microscopy before and after the corrosion test showed coating defects and the occurrence of corrosion process. (author)

  18. The ear region of Latimeria chalumnae: functional and evolutionary implications.

    Science.gov (United States)

    Bernstein, Peter

    2003-01-01

    The anatomy of Latimeria chalumnae has figured prominently in discussions about tetrapod origins. While the gross anatomy of Latimeria is well documented, relatively little is known about its otic anatomy and ontogeny. To examine the inner ear and the otoccipital part of the cranium, a serial-sectioned juvenile coelacanth was studied in detail and a three-dimensional reconstruction was made. The ear of Latimeria shows a derived condition compared to other basal sarcopterygians in having a connection between left and right labyrinths. This canalis communicans is perilymphatic in nature and originates at the transition point of the saccule and the lagena deep in the inner ear, where a peculiar sense end organ can be found. In most gnathostomes the inner ears are clearly separated from each other. A connection occurs in some fishes, e.g. within the Ostariophysi. In the sarcopterygian lineage no connections between the inner ears are known except in the Actinistia. Some fossil actinistians show a posteriorly directed duct lying between the foramen magnum and the notochordal canal, similar to the condition in the ear of Latimeria, so this derived character complex probably developed early in actinistian history. Because some features of the inner ear of Latimeria have been described as having tetrapod affinities, the problem of hearing and the anatomy of the otical complex in the living coelacanth has been closely connected to the question of early tetrapod evolution. It was assumed in the past that the structure found in Latimeria could exemplify a transitional stage in otic evolution between the fishlike sarcopterygians and the first tetrapods in a functional or even phylogenetic way. Here the possibility is considered that the canalis communicans does not possess any auditory function but rather is involved in sensing pressure changes during movements involving the intracranial joint. Earlier hypotheses of a putative tympanic ear are refuted.

  19. Prevalence of external ear disorders in Belgian stray cats.

    Science.gov (United States)

    Bollez, Anouck; de Rooster, Hilde; Furcas, Alessandra; Vandenabeele, Sophie

    2018-02-01

    Objectives Feline otitis externa is a multifactorial dermatological disorder about which very little is known. The objective of this study was to map the prevalence of external ear canal disorders and the pathogens causing otitis externa in stray cats roaming around the region of Ghent, Belgium. Methods One hundred and thirty stray cats were randomly selected during a local trap-neuter-return programme. All cats were European Shorthairs. This study included clinical, otoscopic and cytological evaluation of both external ears of each cat. Prospective data used as parameters in this study included the sex, age and body condition score of each cat, as well as the presence of nasal and/or ocular discharge, and the results of feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) Snap tests. Results Remarkably, very few (sub)clinical problems of the external ear canal were found in the stray cat population. Malassezia species was by far the most common organism found in the external ear canals of the 130 stray cats. A total of 96/130 (74%) cats were found to have Malassezia species organisms present in one or both ears based on the cytological examination. No correlation was found between the parameters of sex, age, body condition score, the presence of nasal and/or ocular discharge and FIV and FeLV status, and the presence of parasites, bacteria or yeasts. Conclusions and relevance This study provides more information about the normal state of the external ear canal of stray cats. The ears of most stray cats are relatively healthy. The presence of Malassezia species organisms in the external ear canal is not rare among stray cats.

  20. Cisplatin Ototoxicity Blocks Sensory Regeneration in the Avian Inner Ear

    OpenAIRE

    Slattery, Eric L.; Warchol, Mark E.

    2010-01-01

    Cisplatin is a chemotherapeutic agent that is widely-used in the treatment of solid tumors. Ototoxicity is a common side effect of cisplatin therapy, and often leads to permanent hearing loss. The sensory organs of the avian ear are able to regenerate hair cells after aminoglycoside ototoxicity. This regenerative response is mediated by supporting cells, which serve as precursors to replacement hair cells. Given the antimitotic properties of cisplatin, we examined whether the avian ear was al...

  1. Cochlear implantation in the Mondini inner ear malformation.

    Science.gov (United States)

    Miyamoto, R T; Robbins, A J; Myres, W A; Pope, M L

    1986-07-01

    We report the case of a profoundly deaf 4-year-old boy with congenital deafness as a result of Mondini's dysplasia. The Mondini inner ear malformation is the result of arrested labyrinthine development during embryogenesis and is characterized by both bony and membranous anomalies of the inner ear. The dysplastic cochlear anatomy does not preclude successful cochlear implantation, and electrical threshold measurements are similar to those recorded in pediatric subjects deafened as a result of other causes.

  2. Melanoacanthoma of external ear: Report of two cases

    Directory of Open Access Journals (Sweden)

    Rashmi Patnayak

    2013-01-01

    Full Text Available Melanoacanthoma is a rare lesion. Melanoacanthoma of external ear is still rarer . We present two cases of melanoacanthoma of external ear in adults which presented as pigmented growths and clinically were suspected as malignant lesions. Histopathology was diagnostic as it demonstrated the characteristic elevated lesion with abundant melanin pigment. No recurrence of the lesion was reported after four years of initial diagnosis. These cases have been presented because of their uncommon location, highlighting the differential diagnoses.

  3. Poor Oral Hygiene and Middle Ear Infections: Any Relationship?

    OpenAIRE

    Esra, Eryaman; Banu, Oter Ilhan; Erdinc, Aydin

    2013-01-01

    The purpose of this study is to evaluate the relationship between poor oral hygiene and middle ear infections. 59 children between 3–12 age intervals were included in this study. The ears were examined by microscope. The findings were marked according to Kempthorne clinical scale and tympanograms were performed. For data analysis of dental caries, dft and DMFT indexes were used in accordance with WHO (World Health Organization) criteria for oral health surveys. The oral hygiene status was det...

  4. Effect of laryngoscopy on middle ear pressure during anaesthesia induction

    OpenAIRE

    Degerli, Semih; Acar, Baran; Sahap, Mehmet; Horasanlı, Eyup

    2013-01-01

    Aims: The procedure of laryngoscopic orotracheal intubation (LOTI) has many impacts on several parts of the body. But its effect on middle ear pressure (MEP) is not known well. The purpose of this study is to evaluate the MEP changes subsequent to insertion of endotracheal tube with laryngoscope. Subjects and methods: 44 patients were included in this study with a normal physical examination of ear, nose and throat. A standard general anaesthesia induction without any inhaler agent was perfor...

  5. GENERAL SURGERY

    African Journals Online (AJOL)

    in the endoscopy room. GENERAL SURGERY. T du Toit, O C Buchel, S J A Smit. Department of Surgery, University of the Free State, Bloemfontein, ... The lack of video instrumentation in developing countries: Redundant fibre-optic instruments (the old. “eye scope”) are still being used. This instrument brings endoscopists ...

  6. GENERAL SURGERY

    African Journals Online (AJOL)

    mean time to first surgery post burn was 11.5 days with a median volume of 0.73 mls/kg/% ..... Mode. Mean (SD). Upper limit. 95% CI. Lower limit. 95% CI. Mode. Elective surgery .... evaluating single-unit red blood cell transfusions in reducing.

  7. Modeling of the incudo-malleolar joint within a biomechanical model of the human ear

    International Nuclear Information System (INIS)

    Ihrle, Sebastian; Eiber, Albrecht; Eberhard, Peter

    2017-01-01

    Under large quasi-static loads, the incudo-malleolar joint (IM joint), connecting the malleus and the incus, is highly mobile. It can be classified as a mechanical filter decoupling large quasi-static motions while transferring small dynamic excitations. To investigate the influence of the behavior of the IM joint, a detailed simulation model of the IM-complex is created. Mathematical modeling of the IM joint behavior under quasi-static excitation requires adequate modeling of the mechanics of the diarthrodial joint. Therefore, the geometry of the articular surfaces, the ligaments, as well as their viscoelastic properties have to be included in the model. The contact of the articular surfaces is implemented using a penalty based contact formulation utilizing the geometric information obtained from micro computer tomography (micro-CT) scans. The ligaments of the joint capsule are modeled by distributing force elements along the joint capsule, with the position and orientation derived from the micro-CT scans. It is shown that the effects which were observed in measurements on human temporal bones are described adequately by the model, if the contact of the articular surfaces and the preload of the viscoelastic fibers are taken into account in the simulation model. In the following, the detailed model is implemented in an elastic multibody system of the entire ear. The model allows the study of different quasi-static load cases of the ossicles, such as it occurs in the reconstruction of the middle ear and form the basis for future simulative studies of sound transmission in natural or reconstructed ears.

  8. Modeling of the incudo-malleolar joint within a biomechanical model of the human ear

    Energy Technology Data Exchange (ETDEWEB)

    Ihrle, Sebastian; Eiber, Albrecht; Eberhard, Peter, E-mail: peter.eberhard@itm.uni-stuttgart.de [University of Stuttgart, Institute of Engineering and Computational Mechanics (Germany)

    2017-04-15

    Under large quasi-static loads, the incudo-malleolar joint (IM joint), connecting the malleus and the incus, is highly mobile. It can be classified as a mechanical filter decoupling large quasi-static motions while transferring small dynamic excitations. To investigate the influence of the behavior of the IM joint, a detailed simulation model of the IM-complex is created. Mathematical modeling of the IM joint behavior under quasi-static excitation requires adequate modeling of the mechanics of the diarthrodial joint. Therefore, the geometry of the articular surfaces, the ligaments, as well as their viscoelastic properties have to be included in the model. The contact of the articular surfaces is implemented using a penalty based contact formulation utilizing the geometric information obtained from micro computer tomography (micro-CT) scans. The ligaments of the joint capsule are modeled by distributing force elements along the joint capsule, with the position and orientation derived from the micro-CT scans. It is shown that the effects which were observed in measurements on human temporal bones are described adequately by the model, if the contact of the articular surfaces and the preload of the viscoelastic fibers are taken into account in the simulation model. In the following, the detailed model is implemented in an elastic multibody system of the entire ear. The model allows the study of different quasi-static load cases of the ossicles, such as it occurs in the reconstruction of the middle ear and form the basis for future simulative studies of sound transmission in natural or reconstructed ears.

  9. Sound pressure gain produced by the human middle ear.

    Science.gov (United States)

    Kurokawa, H; Goode, R L

    1995-10-01

    The acoustic function of the middle ear is to match sound passing from the low impedance of air to the high impedance of cochlear fluid. Little information is available on the actual middle ear pressure gain in human beings. This article describes experiments on middle ear pressure gain in six fresh human temporal bones. Stapes footplate displacement and phase were measured with a laser Doppler vibrometer before and after removal of the tympanic membrane, malleus, and incus. Acoustic insulation of the round window with clay was performed. Umbo displacement was also measured before tympanic membrane removal to assess baseline tympanic membrane function. The middle ear has its major gain in the lower frequencies, with a peak near 0.9 kHz. The mean gain was 23.0 dB below 1.0 kHz, the resonant frequency of the middle ear; the mean peak gain was 26.6 dB. Above 1.0 kHz, the second pressure gain decreased at a rate of -8.6 dB/octave, with a mean gain of 6.5 dB at 4.0 kHz. Only a small amount of gain was present above 7.0 kHz. Significant individual differences in pressure gain were found between ears that appeared related to variations in tympanic membrane function and not to variations in cochlear impedance.

  10. The role of MRI in suspected inner ear malformations

    International Nuclear Information System (INIS)

    Koesling, S.; Juettemann, S.; Amaya, B.; Rasinski, C.; Bloching, M.; Koenig, E.

    2003-01-01

    Purpose: This is a prospective analysis of the value of MRI in suspected inner ear malformations. Materials and Methods: In 50 patients (43 children and young adults, 7 adults) with suspected inner ear malformation MRI (1.5 T) was performed. In addition, 42 of these patients underwent CT. For the analysis of the inner ear structures, the constructive interference in steady state (CISS) sequence with 0.7 mm slice thickness was used. Functional tests revealed a sensorineural hearing loss or deafness in 82 temporal bones (TB) and a combined hearing loss in 4 TB. The hearing loss was unilateral in 14 patients. MRI and CT findings were compared. Results: Imaging findings were normal in 58 TB. The pathological findings included inner ear malformations (35 TB), inflammatory changes (4 TB), partial obliteration of labyrinth (2 TB) and congenital aural atresia (1 TB). An isolated absence of the cochlear nerve (1 TB) could only be found by MRI. In the remaining cases, an inner ear malformation was diagnosed by MRI and CT with the same confidence but MRI was superior in displaying the fine details. Conclusions: MRI will become the method of choice in the diagnosis of inner ear malformations. (orig.) [de

  11. Inner ear test battery in guinea pig models - a review.

    Science.gov (United States)

    Young, Yi-Ho

    2018-06-01

    This study reviewed the development of the inner ear test battery comprising auditory brainstem response (ABR), and caloric, ocular vestibular-evoked myogenic potential (oVEMP), and cervical vestibular-evoked myogenic potential (cVEMP) tests in guinea pig models at our laboratory over the last 20 years. Detailed description of the methodology for testing the small animals is also included. Inner ear disorders, i.e. ototoxicity, noise exposure, or perilymph fistula were established in guinea pig models first. One to four weeks after operation, each animal underwent ABR, oVEMP, cVEMP, and caloric tests. Then, animals were sacrificed for morphological study in the temporal bones. Inner ear endorgans can be comprehensively evaluated in guinea pig models via an inner ear test battery, which provides thorough information on the cochlea, saccule, utricle, and semicircular canal function of guinea pigs. Coupled with morphological study in the temporal bones of the animals may help elucidate the mechanism of inner ear disorders in humans. The inner ear test battery in guinea pig models may encourage young researchers to perform basic study in animals and stimulate the progress of experimental otology which is in evolution.

  12. Lumped parametric model of the human ear for sound transmission.

    Science.gov (United States)

    Feng, Bin; Gan, Rong Z

    2004-09-01

    A lumped parametric model of the human auditoria peripherals consisting of six masses suspended with six springs and ten dashpots was proposed. This model will provide the quantitative basis for the construction of a physical model of the human middle ear. The lumped model parameters were first identified using published anatomical data, and then determined through a parameter optimization process. The transfer function of the middle ear obtained from human temporal bone experiments with laser Doppler interferometers was used for creating the target function during the optimization process. It was found that, among 14 spring and dashpot parameters, there were five parameters which had pronounced effects on the dynamic behaviors of the model. The detailed discussion on the sensitivity of those parameters was provided with appropriate applications for sound transmission in the ear. We expect that the methods for characterizing the lumped model of the human ear and the model parameters will be useful for theoretical modeling of the ear function and construction of the ear physical model.

  13. The ear in fetal MRI: what can we really see?

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Nuno Canto [Neuroradiology Section C., Campos Costa, Fragosela, Viseu (Portugal); Uppsala University, Department of Radiology, Uppsala (Sweden); Teixeira, Joao [Department of Neuroradiology, Porto (Portugal); Raininko, Raili; Wikstrom, Johan [Uppsala University, Department of Radiology, Uppsala (Sweden)

    2011-12-15

    The aim of this study was to investigate the ability to depict the components of the ear on brain-oriented fetal MRI studies. Retrospective evaluation of the ear in MRI studies was performed post-mortem in 16 fetuses ranging from 15 to 22 gestation weeks (GW), and in 122 examinations in vivo of fetuses ranging from 20 to 38 GW. The cochlea, vestibular apparatus, middle ear, and external auditory canal were separately graded according to the components that were delineated. The components of the inner and middle ear were fully delineated in 100% of the post-mortem examinations, but the external auditory canals were only seen in only 25%. In the in vivo group, the imaging detail was much lower. Cochlear turns could be identified in 75% of the fetuses, the vestibule and the lateral semicircular canals in 72% andossicles in 70%. Before 25 GW, the ability to identify these individual parts was 50%, 30%, and 33%, respectively, and above it was 89%, 93%, and 90%. In most cases, the external auditory canals could only be seen after 29 GW. In fetal MRI studies in vivo, it is possible to depict the components of the ear in the majority of the fetuses, in such a manner as to exclude major malformations. However, MRI might not provide enough detail to rule out pathology of the ear before 25 GW, this being a critical age for pregnancy management in many countries. (orig.)

  14. [HRCT imaging characterized of congenital abnormalities of the inner ear in 45 cases].

    Science.gov (United States)

    Wang, Jinling; Meng, Meijuan; Huan, Yi; Zhang, Jinsong

    2003-10-01

    To explore the high resolution CT (HRCT) image characterized of congenital abnormalities of the inner ear(CAIE), and its value in the diagnosis and treatment of CAIE. The clinic data and axial HRCT scans of CAIE in 45 cases were analyzed. In 45 CAIE patients, most of them were frequently associated with slowly progressive sensorineural hearing loss in childhood, 15 ears were fluctuating hearing loss. Seventeen ears were unilateral semicircular canal paralysis. HRCT showed that Michel type 3 cases(4 ears), Mondini type 25 cases(39 ears). Large vestibular aqueduct malformation not associated with anomalies of inner ears 13 cases(23 ears), anomalies of internal auditory canal 4 cases (5 ears). Thirteen ears were associated with outer and middle ear malformation. HRCT image has the important value in the diagnosis and treatment of CAIE, especially for the excerpt of indication of cochlear implantation.

  15. Choosing surgery

    DEFF Research Database (Denmark)

    Thorstensson, Carina; Lohmander, L; Frobell, Richard

    2009-01-01

    -depth qualitative interviews were conducted with young (aged 18-35), physically active individuals with ACL rupture who were participating in a RCT comparing training and surgical reconstruction with training only. 22/34 were randomised to training only but crossed over to surgery. Of these, 11 were interviewed......ABSTRACT: BACKGROUND: The objective was to understand patients' views of treatment after acute anterior cruciate ligament (ACL) injury, and their reasons for deciding to request surgery despite consenting to participate in a randomised controlled trial (to 'cross-over'). METHODS: Thirty-four in...... before surgery, and 11 were interviewed at least 6 months after surgery. To provide additional information, 12 patients were interviewed before randomisation. Interviews were audio-recorded, transcribed and analysed using the Framework approach. RESULTS: Strong preference for surgery was commonplace...

  16. Repair of Tympanic Membrane Perforations with Customized Bioprinted Ear Grafts Using Chinchilla Models.

    Science.gov (United States)

    Kuo, Che-Ying; Wilson, Emmanuel; Fuson, Andrew; Gandhi, Nidhi; Monfaredi, Reza; Jenkins, Audrey; Romero, Maria; Santoro, Marco; Fisher, John P; Cleary, Kevin; Reilly, Brian

    2018-03-01

    The goal of this work is to develop an innovative method that combines bioprinting and endoscopic imaging to repair tympanic membrane perforations (TMPs). TMPs are a serious health issue because they can lead to both conductive hearing loss and repeated otitis media. TMPs occur in 3-5% of cases after ear tube placement, as well as in cases of acute otitis media (the second most common infection in pediatrics), chronic otitis media with or without cholesteatoma, or as a result of barotrauma to the ear. About 55,000 tympanoplasties, the surgery performed to reconstruct TMPs, are performed every year, and the commonly used cartilage grafting technique has a success rate between 43% and 100%. This wide variability in successful tympanoplasty indicates that the current approach relies heavily on the skill of the surgeon to carve the shield graft into the shape of the TMP, which can be extremely difficult because of the perforation's irregular shape. To this end, we hypothesized that patient specific acellular grafts can be bioprinted to repair TMPs. In vitro data demonstrated that our approach resulted in excellent wound healing responses (e.g., cell invasion and proliferations) using our bioprinted gelatin methacrylate constructs. Based on these results, we then bioprinted customized acellular grafts to treat TMP based on endoscopic imaging of the perforation and demonstrated improved TMP healing in a chinchilla study. These ear graft techniques could transform clinical practice by eliminating the need for hand-carved grafts. To our knowledge, this is the first proof of concept of using bioprinting and endoscopic imaging to fabricate customized grafts to treat tissue perforations. This technology could be transferred to other medical pathologies and be used to rapidly scan internal organs such as intestines for microperforations, brain covering (Dura mater) for determination of sites of potential cerebrospinal fluid leaks, and vascular systems to determine arterial

  17. Real ear unaided gain and its relation with the equivalent volume of the external and middle ear

    Directory of Open Access Journals (Sweden)

    Bastos, Bárbara Guimarães

    2012-01-01

    Full Text Available Introduction: Old age is associated with changes in the characteristics of the middle ear transmission system and in external ear resonance, and these carry implications for the hearing aid (HA verification process for which targets and measures of the real ear insertion gain (REIG are used. Aim: To compare the real ear unaided gain (REUG and the equivalent volumes of the external ear (VeqEE and the middle ear (VeqME between elderly and adult patients. Methods: This is a retrospective study in which the medical records of 28 elderly patients (aged between 61 and 102 years, average hearing thresholds between 38.75 and 85 dB HL and 23 adult patients (aged 20-59, mean hearing thresholds between 31.25 and 116.25 dB HL with bilateral sensorineural hearing loss and no history of middle ear abnormalities were analyzed. Immittance measurements (VeqEE, VeqME, and pressure of the peak of maximum compliance and the REUG (frequency and amplitude of the primary peak were recovered for a total of 40 ears. These data were compared between elderly and adults as well as between men and women, using Student's t test. Correlations (Pearson between immittance and REUG data were also verified. Results: No statistically significant differences (p < 0.01 were found for immittance and REUG data between elderly and adults, or between men and women. A negative and weak but significant correlation was observed between the REUG primary peak and VeqEE. Conclusion: Hearing aid verification can be performed with target and measures of the REIG in the elderly population.

  18. FT-IR Microspectroscopy of Rat Ear Cartilage.

    Directory of Open Access Journals (Sweden)

    Benedicto de Campos Vidal

    Full Text Available Rat ear cartilage was studied using Fourier transform-infrared (FT-IR microspectroscopy to expand the current knowledge which has been established for relatively more complex cartilage types. Comparison of the FT-IR spectra of the ear cartilage extracellular matrix (ECM with published data on articular cartilage, collagen II and 4-chondroitin-sulfate standards, as well as of collagen type I-containing dermal collagen bundles (CBs with collagen type II, was performed. Ear cartilage ECM glycosaminoglycans (GAGs were revealed histochemically and as a reduction in ECM FT-IR spectral band heights (1140-820 cm-1 after testicular hyaluronidase digestion. Although ear cartilage is less complex than articular cartilage, it contains ECM components with a macromolecular orientation as revealed using polarization microscopy. Collagen type II and GAGs, which play a structural role in the stereo-arrangement of the ear cartilage, contribute to its FT-IR spectrum. Similar to articular cartilage, ear cartilage showed that proteoglycans add a contribution to the collagen amide I spectral region, a finding that does not recommend this region for collagen type II quantification purposes. In contrast to articular cartilage, the symmetric stretching vibration of -SO3- groups at 1064 cm-1 appeared under-represented in the FT-IR spectral profile of ear cartilage. Because the band corresponding to the asymmetric stretching vibration of -SO3- groups (1236-1225 cm-1 overlapped with that of amide III bands, it is not recommended for evaluation of the -SO3- contribution to the FT-IR spectrum of the ear cartilage ECM. Instead, a peak (or shoulder at 1027-1016 cm-1 could be better considered for this intent. Amide I/amide II ratios as calculated here and data from the literature suggest that protein complexes of the ear cartilage ECM are arranged with a lower helical conformation compared to pure collagen II. The present results could motivate further studies on this tissue

  19. Ear-lobe keloids: treatment by a protocol of surgical excision and immediate postoperative adjuvant radiotherapy.

    Science.gov (United States)

    Ragoowansi, R; Cornes, P G; Glees, J P; Powell, B W; Moss, A L

    2001-09-01

    There is no universally agreed policy for treating keloid scars of the ear lobe following piercing. We treated 35 patients (34 women) for high-risk ear-lobe keloids; the average age was 24 years (range: 16-44 years). All had failed to respond to prior treatment with massage and silicone, and corticosteroid injection. The keloids were excised extralesionally and the defects were closed with interrupted prolene sutures. The operative scar was covered with topical 2% lignocaine-0.25% chlorhexidine sterile lubricant gel under a transparent adhesive dressing. Adjuvant postoperative radiotherapy of 10 Gy, applied as 100 kV photons (4 mm high-voltage therapy (HVT) Al), was given within 24 h of surgery. All keloid scars were controlled at 4 weeks' follow-up. At 1 year, three out of 34 cases followed up had relapsed (probability of control: 91.2%). At 5 years, a further four out of the remaining 31 patients had relapsed (cumulative probability of control at 5 years: 79.4%). There were no cases of serious toxicity. Copyright 2001 The British Association of Plastic Surgeons.

  20. Segmentation and reconstruction of the 3D geometry of the middle and inner ear

    Directory of Open Access Journals (Sweden)

    Lu Yanfei

    2017-01-01

    Full Text Available The anatomical model of the ear is of great importance in the design of ossicular prosthesis, cochlear implant electrodes, as well as for the preoperative planning and navigation of surgery. By means of micro-computed tomography (micro-CT and technology of 3D reconstruction, an anatomical model of the middle and inner ear was built. Region of interest includes the ossicular chain (malleus, incus, and stapes, cochlea (scala vestibule-ST, scala tympani-ST, basilar membrane-BM, spiral ligament-SL and osseous spiral lamina-OSL, tympanic membrane-TM, oval window membrane-OWM, round window membrane-OWM and stapedial annular ligament-SAL. The micro-CT images of a cadaver’s temporal bone were acquired by “SkyScan 1076” (Kontich, Belgium, www.skyscan.be and then reconstructed to cross-section images by SkyScan NRecon™ (v1.6.10.4. The image processing and 3D geometry reconstruction of temporal bone were performed by software Mimics® (v14.0, Materialise NV, Leuven, Belgium. The obtained structures are measured and validated against literature data and the results are in good agreement.