WorldWideScience

Sample records for ear pressure control

  1. Pressure difference receiving ears

    DEFF Research Database (Denmark)

    Michelsen, Axel; Larsen, Ole Næsbye

    2007-01-01

    Directional sound receivers are useful for locating sound sources, and they can also partly compensate for the signal degradations caused by noise and reverberations. Ears may become inherently directional if sound can reach both surfaces of the eardrum. Attempts to understand the physics...... of the eardrum. The mere existence of sound transmission to the inner surface does not ensure a useful directional hearing, since a proper amplitude and phase relationship must exist between the sounds acting on the two surfaces of the eardrum. The gain of the sound pathway must match the amplitude and phase...... of the sounds at the outer surfaces of the eardrums, which are determined by diffraction and by the arrival time of the sound, that is by the size and shape of the animal and by the frequency of sound. Many users of hearing aids do not obtain a satisfactory improvement of their ability to localize sound sources...

  2. Pressure equilibration in the penguin middle ear.

    Science.gov (United States)

    Sadé, Jacob; Handrich, Yves; Bernheim, Joelle; Cohen, David

    2008-01-01

    King penguins have a venous structure in the form of a corpus cavernosum (CC) in their middle ear (ME) submucosa. The CC may be viewed as a special organelle that can change ME volume for pressure equilibration during deep-sea diving it is a pressure regulating organelle (PRO). A similar CC and muscles also surround the external ear (EE) and may constrict it, isolating the tympanic membrane from the outside. A CC was previously found also in the ME of marine diving mammals and can be expected to exist in other deep diving animals, such as marine turtles. Marine animals require equalization of middle ear (ME) pressure when diving hundreds or thousands of meters to catch prey. We investigated what mechanism enables king penguins to protect their ME when they dive to great depths. Biopsies and serial sections of the ME and the EE of the deep diving king penguin (Aptenodytes patagonicus) were examined microscopically. It was demonstrated that the penguin ME has an extensive network of small and large submucosal venous sinuses. This venous formation, a corpus cavernosum, can expand and potentially 'flood' the ME almost completely on diving, thus elevating ME pressure and reducing the ME space. The EE has a similar protective mechanism.

  3. Inner ear pressure changes following square wave intracranial or ear canal pressure manipulation in the same guinea pig

    NARCIS (Netherlands)

    Thalen, E; Wit, H; Segenhout, H; Albers, F

    Inner ear pressure was measured in scala tympani with a micropipette during square wave pressure manipulation of the intracranial compartment and, subsequently, of the external ear canal (EEC) in the same guinea pig. As expected, the combination of the cochlear aqueduct and the inner ear behaves as

  4. Sound pressure gain produced by the human middle ear.

    Science.gov (United States)

    Kurokawa, H; Goode, R L

    1995-10-01

    The acoustic function of the middle ear is to match sound passing from the low impedance of air to the high impedance of cochlear fluid. Little information is available on the actual middle ear pressure gain in human beings. This article describes experiments on middle ear pressure gain in six fresh human temporal bones. Stapes footplate displacement and phase were measured with a laser Doppler vibrometer before and after removal of the tympanic membrane, malleus, and incus. Acoustic insulation of the round window with clay was performed. Umbo displacement was also measured before tympanic membrane removal to assess baseline tympanic membrane function. The middle ear has its major gain in the lower frequencies, with a peak near 0.9 kHz. The mean gain was 23.0 dB below 1.0 kHz, the resonant frequency of the middle ear; the mean peak gain was 26.6 dB. Above 1.0 kHz, the second pressure gain decreased at a rate of -8.6 dB/octave, with a mean gain of 6.5 dB at 4.0 kHz. Only a small amount of gain was present above 7.0 kHz. Significant individual differences in pressure gain were found between ears that appeared related to variations in tympanic membrane function and not to variations in cochlear impedance.

  5. Effect of laryngoscopy on middle ear pressure during anaesthesia induction

    OpenAIRE

    Degerli, Semih; Acar, Baran; Sahap, Mehmet; Horasanlı, Eyup

    2013-01-01

    Aims: The procedure of laryngoscopic orotracheal intubation (LOTI) has many impacts on several parts of the body. But its effect on middle ear pressure (MEP) is not known well. The purpose of this study is to evaluate the MEP changes subsequent to insertion of endotracheal tube with laryngoscope. Subjects and methods: 44 patients were included in this study with a normal physical examination of ear, nose and throat. A standard general anaesthesia induction without any inhaler agent was perfor...

  6. Sheep as a large animal ear model: Middle-ear ossicular velocities and intracochlear sound pressure.

    Science.gov (United States)

    Péus, Dominik; Dobrev, Ivo; Prochazka, Lukas; Thoele, Konrad; Dalbert, Adrian; Boss, Andreas; Newcomb, Nicolas; Probst, Rudolf; Röösli, Christof; Sim, Jae Hoon; Huber, Alexander; Pfiffner, Flurin

    2017-08-01

    Animals are frequently used for the development and testing of new hearing devices. Dimensions of the middle ear and cochlea differ significantly between humans and commonly used animals, such as rodents or cats. The sheep cochlea is anatomically more like the human cochlea in size and number of turns. This study investigated the middle-ear ossicular velocities and intracochlear sound pressure (ICSP) in sheep temporal bones, with the aim of characterizing the sheep as an experimental model for implantable hearing devices. Measurements were made on fresh sheep temporal bones. Velocity responses of the middle ear ossicles at the umbo, long process of the incus and stapes footplate were measured in the frequency range of 0.25-8 kHz using a laser Doppler vibrometer system. Results were normalized by the corresponding sound pressure level in the external ear canal (P EC ). Sequentially, ICSPs at the scala vestibuli and tympani were then recorded with custom MEMS-based hydrophones, while presenting identical acoustic stimuli. The sheep middle ear transmitted most effectively around 4.8 kHz, with a maximum stapes velocity of 0.2 mm/s/Pa. At the same frequency, the ICSP measurements in the scala vestibuli and tympani showed the maximum gain relative to the P EC (24 dB and 5 dB, respectively). The greatest pressure difference across the cochlear partition occurred between 4 and 6 kHz. A comparison between the results of this study and human reference data showed middle-ear resonance and best cochlear sensitivity at higher frequencies in sheep. In summary, sheep can be an appropriate large animal model for research and development of implantable hearing devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Development of optoelectronic monitoring system for ear arterial pressure waveforms

    Science.gov (United States)

    Sasayama, Satoshi; Imachi, Yu; Yagi, Tamotsu; Imachi, Kou; Ono, Toshirou; Man-i, Masando

    1994-02-01

    Invasive intra-arterial blood pressure measurement is the most accurate method but not practical if the subject is in motion. The apparatus developed by Wesseling et al., based on a volume-clamp method of Penaz (Finapres), is able to monitor continuous finger arterial pressure waveforms noninvasively. The limitation of Finapres is the difficulty in measuring the pressure of a subject during work that involves finger or arm action. Because the Finapres detector is attached to subject's finger, the measurements are affected by inertia of blood and hydrostatic effect cause by arm or finger motion. To overcome this problem, the authors made a detector that is attached to subject's ear and developed and optoelectronic monitoring systems for ear arterial pressure waveform (Earpres). An IR LEDs, photodiode, and air cuff comprised the detector. The detector was attached to a subject's ear, and the space adjusted between the air cuff and the rubber plate on which the LED and photodiode were positioned. To evaluate the accuracy of Earpres, the following tests were conducted with participation of 10 healthy male volunteers. The subjects rested for about five minutes, then performed standing and squatting exercises to provide wide ranges of systolic and diastolic arterial pressure. Intra- and inter-individual standard errors were calculated according to the method of van Egmond et al. As a result, average, the averages of intra-individual standard errors for earpres appeared small (3.7 and 2.7 mmHg for systolic and diastolic pressure respectively). The inter-individual standard errors for Earpres were about the same was Finapres for both systolic and diastolic pressure. The results showed the ear monitor was reliable in measuring arterial blood pressure waveforms and might be applicable to various fields such as sports medicine and ergonomics.

  8. Effect of laryngoscopy on middle ear pressure during anaesthesia induction.

    Science.gov (United States)

    Degerli, Semih; Acar, Baran; Sahap, Mehmet; Horasanlı, Eyup

    2013-01-01

    The procedure of laryngoscopic orotracheal intubation (LOTI) has many impacts on several parts of the body. But its effect on middle ear pressure (MEP) is not known well. The purpose of this study is to evaluate the MEP changes subsequent to insertion of endotracheal tube with laryngoscope. 44 patients were included in this study with a normal physical examination of ear, nose and throat. A standard general anaesthesia induction without any inhaler agent was performed to the all patients. The MEP measurements for both ears were applied under 1 minute; before induction (BI) and after intubation (AI) with a middle ear analyzer. Also hemodynamic parameters were recorded before induction and after intubation. Of the 44 patients were 25 women and 19 men with a 43.5±15.1 mean age. A statistically significant rise in MEP was seen in all patients subsequent to insertion of endotracheal tube (Ptube, size and type of the blades, drugs and face masking time. But on the other hand in our opinion cardiovascular and haemodynamic response to LOTI has the most impact over the middle ear mucosa with mucosal venous congestion.

  9. Cochlear aqueduct flow resistance is not constant during evoked inner ear pressure change in the guinea pig

    NARCIS (Netherlands)

    Wit, HP; Feijen, RA; Albers, FWJ

    Inner ear fluid pressure was measured during 6.25 mHz square wave middle ear pressure manipulation, with a perforated tympanic membrane. After a negative-going middle ear pressure change the calculated flow resistance of the inner ear pressure release routes (mainly the cochlear aqueduct) was

  10. Dynamics of inner ear pressure change caused by intracranial pressure manipulation in the guinea pig

    NARCIS (Netherlands)

    Thalen, EO; Wit, HP; Segenhout, JM; Albers, FWJ

    Previous studies have shown that pressure changes in the cerebrospinal fluid compartment are transmitted to the inner ear. The main route for pressure transfer is the cochlear aqueduct, about which little is known with regard to its dynamic properties. In the present study, sudden intracranial

  11. Custom-made different designs of pressure clips for the management of ear lobe keloids

    Directory of Open Access Journals (Sweden)

    Anshul Chugh

    2013-01-01

    Full Text Available Introduction : Keloids are frequent finding after physical trauma. Keloids of ear lobe are common complication of ear piercing, although its incidence remains unknown. The use of intrakeloid resection and a form pressure device to treat pinna keloids. The recommendation of this therapy is to maintain constant pressure and duration of pressure therapy was about 25 weeks. Clinical innovation : This article will present inexpensive custom made pressure clips of various designs. The dimensions of polymethylmethacrylate (PMMA plates in ear lobe clip presented by us though they esthetically not so good, but colored PMMA has been used to make it decorative and acceptable by most of the patients. This has been an encouraging experience to use the different designs. Discussion : Ear clip prosthesis has been developed for maintaining pressure on ear lobe keloids before and after surgical removal. The prosthesis includes an ear clip to which heat-polymerized acrylic resin is attached, which covers the keloid area. Pressure therapy is widely used to help in the early maturation of scar tissue and to prevent the recurrence of keloid. The preliminary report by Brent revealed that constant light pressure was an effective means of preventing post excision recurrence of ear lobe keloids using a decorative, spring-pressure earring.

  12. Eustachian tube function and middle ear barotrauma associated with extremes in atmospheric pressure.

    Science.gov (United States)

    Miyazawa, T; Ueda, H; Yanagita, N

    1996-11-01

    Eustachian tube (ET) function was studied by means of sonotubometry and tubotympano-aerodynamography (TTAG) prior to and following exposure to hypobaric or hyperbaric conditions. Forty normal adults were subjected to hypobaric pressure. Fifty adults who underwent hyperbaric oxygen (HBO) therapy also were studied. Following hypobaric exposure, 14 of 80 ears (17.5%) exhibited middle ear barotrauma. Following hyperbaric exposure, 34 of 100 ears (34%) exhibited middle ear barotrauma. Dysfunction of the ET, characterized by altered active and passive opening capacity, was more prevalent following exposure to extremes in atmospheric pressure compared to baseline. The ET function, which was impaired after the first HBO treatment, improved gradually over the next 2 hours. Overall, however, ET function was worse after the seventh treatment. The patients who developed barotrauma exhibited worse ET function prior to hypobaric or hyperbaric exposure. Thus, abnormal ET function can be used to predict middle ear barotrauma prior to exposure to hypobaric or hyperbaric atmospheric pressure.

  13. Congestion of mastoid mucosa and influence on middle ear pressure - Effect of retroauricular injection of adrenaline.

    Science.gov (United States)

    Fooken Jensen, Pernille Vita; Gaihede, Michael

    2016-10-01

    Micro-CT scanning of temporal bones has revealed numerous retroauricular microchannels, which connect the outer bone surface directly to the underlying mastoid air cells. Their structure and dimensions have suggested a separate vascular supply to the mastoid mucosa, which may play a role in middle ear (ME) pressure regulation. This role may be accomplished by changes in the mucosa congestion resulting in volumetric changes, which ultimately affect the pressure of the enclosed ME gas pocket (Boyle's law). Further, such mucosa congestion may be susceptible to α-adrenergic stimulation similar to the mucosa of the nose. The purpose of our study was to investigate these hypotheses by recording the ME pressure in response to adrenergic stimulation administered by retroauricular injections at the surface of the microchannels. In a group of 20 healthy adults we measured the ME pressure by tympanometry initially in the sitting position, and then in the supine position over a 5 min period with 30 s intervals. In each subject, the study included 1) a control reference experiment with no intervention, 2) a control experiment with subcutaneously retroauricular injection of 1 ml isotonic NaCl solution, and 3) a test experiment with subcutaneously retroauricular injection of 1 ml NaCl-adrenaline solution. In both control experiments the ME pressure displayed an immediate increase in response to changing body position; this pressure increase remained stable for the entire period up to five minutes. In the test experiments the ME pressure also showed an initial pressure increase, but it was followed by a distinct significant pressure decrease with a maximum after 90 s. The test group was injected with both a 5 and 10% adrenaline solution, but the responses appeared similar for the two concentrations. Subcutaneous retroauricular injection of adrenaline caused a significant pressure decrease in ME pressure compared with control ears. This may be explained by the microchannels

  14. Study the Effect of Nasal Obstruction Surgery (Septoplasty on Eustachian Tube Function and Middle Ear Pressure

    Directory of Open Access Journals (Sweden)

    Rahim Davari

    2014-12-01

    Full Text Available Background & objectives: Deviation of the nasal septum is a common cause of unilateral or bilateral nasal airway obstruction and may follow nasal and midface trauma. Patient complaints of airway obstruction that are consistent with intranasal physical findings often lead to septoplasty and turbinate surgery. Severe nasal septal deviation leads to complete nasal obstruction and disturbs air passage from nostrils, however the effect of septal deviation and nasal obstruction surgery (septoplasty on Eustachian tube function and middle ear pressure is controversial and isn’t clear. Whereas many of surgeons do not believe the considerable effect of septoplasty on Eustachian tube function and middle ear pressure, so they do not recommend this procedure before middle ear surgery. On the other hand, some have an idea that septoplasty has significant effect on middle ear pressure suggesting this procedure before ear surgery like tympanoplasty.   Methods: This prospective analytical-descriptive study was conducted on seventy patients from 18 to 65 years of age who underwent septoplasty due to severe septal deviation leading to nasal obstruction in Beesat Hospital during one year (2012-2013. Middle ear pressure and Eustachian tube function on the septal deviated side and contralateral side before and after septoplasty (3 to 6 months later were measured through tympanometry and Eustachian tube function test (Toynbee test. The comparison between pre- and postoperative ETF tests and middle ear pressures was assessed using Paired –T test and p-value of less than 0.05 was considered as statistically significant.   Results : This study revealed that comparison between mean values of pressure in the deviated and contralateral side has no significant statistical difference before and after septoplasty. Also comparison between Eustachian function in the deviated side and contralateral side showed no significant difference before and after septoplasty.

  15. Ear Acupuncture for Acute Sore Throat: A Randomized Controlled Trial

    Science.gov (United States)

    2014-09-26

    SEP 2014 2. REPORT TYPE Final 3. DATES COVERED 4. TITLE AND SUBTITLE Ear acupuncture for acute sore throat. A randomized controlled trial...Auncular Acupuncture is a low risk option for acute pain control •Battlefield acupuncture (BFA) IS a specific auncular acupuncture technique •BFA IS...Strengths: Prospect1ve RCT •Weaknesses Small sample stze. no sham acupuncture performed, patients not blinded to treatment •Th1s study represents an

  16. Inner-ear sound pressures near the base of the cochlea in chinchilla: Further investigation

    Science.gov (United States)

    Ravicz, Michael E.; Rosowski, John J.

    2013-01-01

    The middle-ear pressure gain GMEP, the ratio of sound pressure in the cochlear vestibule PV to sound pressure at the tympanic membrane PTM, is a descriptor of middle-ear sound transfer and the cochlear input for a given stimulus in the ear canal. GMEP and the cochlear partition differential pressure near the cochlear base ΔPCP, which determines the stimulus for cochlear partition motion and has been linked to hearing ability, were computed from simultaneous measurements of PV, PTM, and the sound pressure in scala tympani near the round window PST in chinchilla. GMEP magnitude was approximately 30 dB between 0.1 and 10 kHz and decreased sharply above 20 kHz, which is not consistent with an ideal transformer or a lossless transmission line. The GMEP phase was consistent with a roughly 50-μs delay between PV and PTM. GMEP was little affected by the inner-ear modifications necessary to measure PST. GMEP is a good predictor of ΔPCP at low and moderate frequencies where PV ⪢ PST but overestimates ΔPCP above a few kilohertz where PV ≈ PST. The ratio of PST to PV provides insight into the distribution of sound pressure within the cochlear scalae. PMID:23556590

  17. Use of the nine-step inflation/deflation test and resting middle-ear pressure range as predictors of middle-ear barotrauma in aircrew members.

    Science.gov (United States)

    Hussein, A; Abousetta, A

    2014-07-01

    To explore the role of the nine-step inflation/deflation tympanometric test and resting middle-ear pressure range as predictors of barotrauma in aircrew members. A prospective, non-randomised study was conducted on 100 aircrew members. Resting middle-ear pressure was measured and the nine-step inflation/deflation test performed on all subjects before flights. Subjects were allocated to two groups according to resting middle-ear pressure range (group A, within the range of +26 to +100 and -26 to -100 mmH2O; group B, -25 to +25 mmH2O). All aircrew members were assessed after flights regarding the presence and the grade of barotrauma. In both groups, the sensitivity and specificity values of the entire post-inflation/deflation test were close to those of the post-deflation part of the test. The post-deflation test had a higher negative predictive value than the post-inflation test. Ears with resting middle-ear pressure lower than -55 mmH2O experienced barotrauma, regardless of good or poor post-inflation or post-deflation test results. In an aircrew member, a resting middle-ear pressure within the range of -55 and +50 mmH2O, together with good post-deflation test results, are considered reliable predictors for fitness to fly.

  18. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  19. What ears do for bats: a comparative study of pinna sound pressure transformation in chiroptera.

    Science.gov (United States)

    Obrist, M K; Fenton, M B; Eger, J L; Schlegel, P A

    1993-07-01

    Using a moveable loudspeaker and an implanted microphone, we studied the sound pressure transformation of the external ears of 47 species of bats from 13 families. We compared pinna gain, directionality of hearing and interaural intensity differences (IID) in echolocating and non-echolocating bats, in species using different echolocation strategies and in species that depend upon prey-generated sounds to locate their targets. In the Pteropodidae, two echolocating species had slightly higher directionality than a non-echolocating species. The ears of phyllostomid and vespertilionid species showed moderate directionality. In the Mormoopidae, the ear directionality of Pteronotus parnellii clearly matched the dominant spectral component of its echolocation calls, unlike the situation in three other species. Species in the Emballonuridae, Molossidae, Rhinopomatidae and two vespertilionids that use narrow-band search-phase echolocation calls showed increasingly sharp tuning of the pinna to the main frequency of their signals. Similar tuning was most evident in Hipposideridae and Rhinolophidae, species specialized for flutter detection via Doppler-shifted echoes of high-duty-cycle narrow-band signals. The large pinnae of bats that use prey-generated sounds to find their targets supply high sound pressure gain at lower frequencies. Increasing domination of a narrow spectral band in echolocation is reflected in the passive acoustic properties of the external ears (sharper directionality). The importance of IIDs for lateralization and horizontal localization is discussed by comparing the behavioural directional performance of bats with their bioacoustical features.

  20. An overview of changes in pressure values of the middle ear using impedance audiometry among diver candidates in a hyperbaric chamber before and after a pressure test

    Science.gov (United States)

    Anoraga, J. S.; Bramantyo, B.; Bardosono, S.; Simanungkalit, S. H.; Basiruddin, J.

    2017-08-01

    Impedance audiometry is not yet routinely used in pressure tests, especially in Indonesia. Direct exposure to pressure in a hyperbaric chamber is sometimes without any assessment of the middle ear or the Eustachian tube function (ETF) of ventilation. Impedance audiometry examinations are important to assess ETF ventilation. This study determined the middle ear pressure value changes associated with the ETF (ventilation) of prospective divers. This study included 29 prospective divers aged 20-40 years without conductive hearing loss. All subjects underwent a modified diving impedance audiometry examination both before and after the pressure test in a double-lock hyperbaric chamber. Using the Toynbee maneuver, the values obtained for changes of pressure in the middle ear were significant before and after the pressure test in the right and left ears: p < 0.001 and p = 0.018, respectively. The impedance audiometry examination is necessary for the selection of candidate divers undergoing pressure tests within a hyperbaric chamber.

  1. The effects of ear acupressure, massage therapy and no therapy on symptoms of dementia: a randomized controlled trial.

    Science.gov (United States)

    Rodríguez-Mansilla, Juan; González López-Arza, María Victoria; Varela-Donoso, Enrique; Montanero-Fernández, Jesús; González Sánchez, Blanca; Garrido-Ardila, Elisa María

    2015-07-01

    To assess the effectiveness of ear acupressure and massage vs. control in the improvement of pain, anxiety and depression in persons diagnosed with dementia. A pilot randomized controlled trial. Residential homes in Extremadura (Spain). A total of 120 elders with dementia institutionalized in residential homes. The participants were randomly allocated, in three groups. Control group - they continued with their routine activities; ear acupressure intervention group - they received ear acupressure treatment (pressure was applied to acupressure points on the ear); and massage therapy intervention group - they received relaxing massage therapy. The variables pain, anxiety and depression were assessed with the Doloplus2, Cornell and Campbell scales. The study was carried out during five months; three months of experimental treatment and two months with no treatment. The assessments were done at baseline, each month during the treatment and at one and two months of follow-up. In the statistical analysis the three groups were compared with each other. A total of 111 participants completed the study. Their aged ranged from 67 to 91 years old and 86 of them (77.4%) were women. The ear acupressure intervention group showed better improvements than the massage therapy intervention group in relation to pain and depression during the treatment period and at one month of follow-up. The best improvement in pain was achieved in the last (3rd) month of ear acupressure treatment (p  massage therapy showed better results than the control group in relation to pain, anxiety and depression. However, ear acupressure achieved more improvements. © The Author(s) 2014.

  2. Hearing with an atympanic ear: good vibration and poor sound-pressure detection in the royal python, Python regius.

    Science.gov (United States)

    Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Brandt, Christian; Madsen, Peter Teglberg

    2012-01-15

    Snakes lack both an outer ear and a tympanic middle ear, which in most tetrapods provide impedance matching between the air and inner ear fluids and hence improve pressure hearing in air. Snakes would therefore be expected to have very poor pressure hearing and generally be insensitive to airborne sound, whereas the connection of the middle ear bone to the jaw bones in snakes should confer acute sensitivity to substrate vibrations. Some studies have nevertheless claimed that snakes are quite sensitive to both vibration and sound pressure. Here we test the two hypotheses that: (1) snakes are sensitive to sound pressure and (2) snakes are sensitive to vibrations, but cannot hear the sound pressure per se. Vibration and sound-pressure sensitivities were quantified by measuring brainstem evoked potentials in 11 royal pythons, Python regius. Vibrograms and audiograms showed greatest sensitivity at low frequencies of 80-160 Hz, with sensitivities of -54 dB re. 1 m s(-2) and 78 dB re. 20 μPa, respectively. To investigate whether pythons detect sound pressure or sound-induced head vibrations, we measured the sound-induced head vibrations in three dimensions when snakes were exposed to sound pressure at threshold levels. In general, head vibrations induced by threshold-level sound pressure were equal to or greater than those induced by threshold-level vibrations, and therefore sound-pressure sensitivity can be explained by sound-induced head vibration. From this we conclude that pythons, and possibly all snakes, lost effective pressure hearing with the complete reduction of a functional outer and middle ear, but have an acute vibration sensitivity that may be used for communication and detection of predators and prey.

  3. Numerical Model on Sound-Solid Coupling in Human Ear and Study on Sound Pressure of Tympanic Membrane

    Directory of Open Access Journals (Sweden)

    Yao Wen-juan

    2011-01-01

    Full Text Available Establishment of three-dimensional finite-element model of the whole auditory system includes external ear, middle ear, and inner ear. The sound-solid-liquid coupling frequency response analysis of the model was carried out. The correctness of the FE model was verified by comparing the vibration modes of tympanic membrane and stapes footplate with the experimental data. According to calculation results of the model, we make use of the least squares method to fit out the distribution of sound pressure of external auditory canal and obtain the sound pressure function on the tympanic membrane which varies with frequency. Using the sound pressure function, the pressure distribution on the tympanic membrane can be directly derived from the sound pressure at the external auditory canal opening. The sound pressure function can make the boundary conditions of the middle ear structure more accurate in the mechanical research and improve the previous boundary treatment which only applied uniform pressure acting to the tympanic membrane.

  4. Sound pressure distribution within natural and artificial human ear canals: forward stimulation.

    Science.gov (United States)

    Ravicz, Michael E; Tao Cheng, Jeffrey; Rosowski, John J

    2014-12-01

    This work is part of a study of the interaction of sound pressure in the ear canal (EC) with tympanic membrane (TM) surface displacement. Sound pressures were measured with 0.5-2 mm spacing at three locations within the shortened natural EC or an artificial EC in human temporal bones: near the TM surface, within the tympanic ring plane, and in a plane transverse to the long axis of the EC. Sound pressure was also measured at 2-mm intervals along the long EC axis. The sound field is described well by the size and direction of planar sound pressure gradients, the location and orientation of standing-wave nodal lines, and the location of longitudinal standing waves along the EC axis. Standing-wave nodal lines perpendicular to the long EC axis are present on the TM surface >11-16 kHz in the natural or artificial EC. The range of sound pressures was larger in the tympanic ring plane than at the TM surface or in the transverse EC plane. Longitudinal standing-wave patterns were stretched. The tympanic-ring sound field is a useful approximation of the TM sound field, and the artificial EC approximates the natural EC.

  5. Pressure buffering by the tympanic membrane. In vivo measurements of middle ear pressure fluctuations during elevator motion.

    Science.gov (United States)

    Padurariu, Simona; de Greef, Daniël; Jacobsen, Henrik; Nlandu Kamavuako, Ernest; Dirckx, Joris J; Gaihede, Michael

    2016-10-01

    The tympanic membrane (TM) represents a pressure buffer, which contributes to the overall pressure regulation of the middle ear (ME). This buffer capacity is based on its viscoelastic properties combined with those of the attached ossicular chain, muscles and ligaments. The current work presents a set of in vivo recordings of the ME pressure variations normally occurring in common life: elevator motion. This is defined as a situation of smooth ambient pressure increase or decrease on a limited range and at a low rate of pressure change. Based on these recordings, the purpose was a quantitative analysis of the TM buffer capacity including the TM compliance. The pressure changes in seven normal adult ME's with intact TM's were continuously recorded directly inside the ME cavity during four different elevator trips using a high precision instrument. The TM buffer capacity was determined by the ratio between the changes in ME and the ambient pressure. Further, the ME volumes were calculated by Boyle's Law from pressure recordings during inflation-deflation tests; subsequently the TM compliance could also be calculated. Finally, the correlation between the ME volume and buffer function was determined. Twenty-one elevator trips could be used for the analysis. The overall mean TM pressure buffering capacity was 23.3% (SEM = 3.4), whereas the mean overall compliance was 28.9 × 10 -3  μL/Pa (SEM = 4.8). A strong negative linear correlation was found between the TM buffer capacity and the ME volumes (R 2  = 0.92). These results were in fair agreement with the literature obtained in clinical as well as temporal bone experiments, and they provide an in vivo reference for the normal ME function as well as for ME modeling. The TM buffer capacity was found more efficient in smaller mastoids. Possible clinical implications are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Ear Infection (Middle Ear)

    Science.gov (United States)

    ... secretions from the middle ear Swelling, inflammation and mucus in the eustachian tubes from an upper respiratory ... your baby for at least six months. Breast milk contains antibodies that may offer protection from ear ...

  7. Investigation of the Sound Pressure Level (SPL) of earphones during music listening with the use of physical ear canal models

    Science.gov (United States)

    Aying, K. P.; Otadoy, R. E.; Violanda, R.

    2015-06-01

    This study investigates on the sound pressure level (SPL) of insert-type earphones that are commonly used for music listening of the general populace. Measurements of SPL from earphones of different respondents were measured by plugging the earphone to a physical ear canal model. Durations of the earphone used for music listening were also gathered through short interviews. Results show that 21% of the respondents exceed the standard loudness/duration relation recommended by the World Health Organization (WHO).

  8. Ear acupuncture in the control of migraine pain: selecting the right acupoints by the "needle-contact test".

    Science.gov (United States)

    Romoli, M; Allais, G; Airola, G; Benedetto, C

    2005-05-01

    There is increasing evidence that somatic acupuncture can be helpful in migraine treatment, but substantial data on ear acupuncture (EAP) are still lacking. EAP can be useful both in the diagnosis and in the treatment of many medical conditions. As regards the control of migrainous pain, we present a case report in which a procedure called the "needle-contact test" is described in detail. During a migraine attack, the patient undergoes an accurate search for tender points of the outer ear by means of a specific pressure algometer. Once the most sensitive point has been identified, an acupuncture needle is placed in contact with it for about 10 s, without skin penetration. The expected effect is a quick and evident reduction of acute pain. If no appreciable variation in pain intensity occurs within the following 60 s, a second or third attempt is made on other previously identified tender points, until the point at which the patient notices a clear remission of pain is found. In this positive case, the same testing needle can be immediately used for therapy, completely penetrating the skin, and then extracted after about 30 min. Alternatively, a temporary needle can be implanted and left in situ for a variable period of time (1-15 days). This innovative technique allows the identification, with maximum accuracy, of the most effective ear acupoints on migraine pain during acute attacks.

  9. Ear Acupuncture for Post-Operative Pain Associated with Ambulatory Arthroscopic Knee Surgery: A Randomized Controlled Trial

    Science.gov (United States)

    2014-01-14

    E7(/(3+21(180%(5 ,QFOXGHDUHDFRGH 14 Jan 2014 Final Report Ear acupuncture for post-operative pain associated with ambulatory arthroscopic...DISTRIBUTION A. Approved for public release: distribution unlimited. The purpose of this study is to compare ear acupuncture plus standard therapy versus...3298 Ear Acupuncture for Post-operative Pa111 Assoc1ated With Ambulatory Arthroscopic Knee Surgery A Randomized Controlled Trial ’• V ’’ ’-’ I

  10. Ear Injury

    Science.gov (United States)

    ... of different injuries can affect the outer ear. Cauliflower ear (subperichondrial hematoma) A blunt blow to the ... to a deformed ear. This deformity, called a cauliflower ear, is common among wrestlers, boxers, and rugby ...

  11. Controlling your high blood pressure

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000101.htm Controlling your high blood pressure To use the sharing features on this page, ... JavaScript. Hypertension is another term used to describe high blood pressure. High blood pressure can lead to: Stroke Heart ...

  12. Middle Ear Pressure Regulation - Complementary Action of the Mastoid and Eustachian Tube

    DEFF Research Database (Denmark)

    Gaihede, Michael; Dirckx, Joris J J; Jacobsen, Henrik

    2010-01-01

    , MEP counter-regulation presented as Eustachian tube openings with steep and fast pressure changes toward 0 Pa, whereas in others, gradual and slow pressure changes presented related to the mastoid; these changes sometimes crossed 0 Pa into opposite pressures. In many cases, combinations...... to continuous regulation of smaller pressures, whereas the tube was related to intermittent regulation of higher pressures....

  13. Connectivity analysis of suggestive brain areas involved in middle ear pressure regulation in humans

    DEFF Research Database (Denmark)

    SA, Sami; Gaihede, Michael

    2010-01-01

    , MEP counter-regulation presented as Eustachian tube openings with steep and fast pressure changes toward 0 Pa, whereas in others, gradual and slow pressure changes presented related to the mastoid; these changes sometimes crossed 0 Pa into opposite pressures. In many cases, combinations...... to continuous regulation of smaller pressures, whereas the tube was related to intermittent regulation of higher pressures....

  14. Middle Ear Pressure Regulation - Complementary Action of the Mastoid and Eustachian Tube

    DEFF Research Database (Denmark)

    Gaihede, Michael; Jacobsen, Henrik; Tveterås, Kjell

    , MEP counter-regulation presented as Eustachian tube openings with steep and fast pressure changes toward 0 Pa, whereas in others, gradual and slow pressure changes presented related to the mastoid; these changes sometimes crossed 0 Pa into opposite pressures. In many cases, combinations...... to continuous regulation of smaller pressures, whereas the tube was related to intermittent regulation of higher pressures....

  15. Rhamnolipid Biosurfactant against Fusarium verticillioides to Control Stalk and Ear Rot Disease of Maize

    Directory of Open Access Journals (Sweden)

    Siddhartha Narayan Borah

    2016-09-01

    Full Text Available Antifungal activity of rhamnolipids (RLs has been widely studied against many plant pathogenic fungi, but not against Fusarium verticillioides, a major pathogen of maize (Zea mays L.. F. verticillioides causes stalk and ear rot of maize or asymptomatically colonizes the plant and ears resulting in moderate to heavy crop loss throughout the world. F. verticillioides produces fumonisin mycotoxins, reported carcinogens, which makes the contaminated ears unsuitable for consumption. In this study, the RL produced using glucose as sole carbon source was characterized by FTIR and LCMS analyses and its antifungal activity against F. verticillioides was evaluated in vitro on maize stalks and seeds. Further, the effect of RL on the mycelia of F. verticillioides was investigated by scanning electron microscopy which revealed visible damage to the mycelial structure as compared to control samples. In planta, treatment of maize seeds with a RL concentration of 50 mg l-1 resulted in improved biomass and fruiting compared to those of healthy control plants and complete suppression of characteristic disease symptoms and colonization of maize by F. verticillioides. The study highlights the potential of RLs to be used for an effective biocontrol strategy against colonization of maize plant by F. verticillioides.

  16. Swimmer's Ear

    Science.gov (United States)

    ... Eardrum Taking Care of Your Ears Can Loud Music Hurt My Ears? Your Ears What's Earwax? How Do Pain Relievers Work? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  17. Control of Fusarium verticillioides, cause of ear rot of maize, by Pseudomonas fluorescens.

    Science.gov (United States)

    Nayaka, Siddaiah Chandra; Shankar, Arakere C Udaya; Reddy, Munagala S; Niranjana, Siddapura R; Prakash, Harishchandra S; Shetty, Hunthrike S; Mortensen, Carmen N

    2009-07-01

    Maize is one of the staple food crops grown in India. Fusarium verticillioides (Sacc.) Nirenberg is the most important fungal pathogen of maize, associated with diseases such as ear rot and kernel rot. Apart from the disease, it is capable of producing fumonisins, which have elicited considerable attention over the past decade owing to their association with animal disease syndromes. Hence, the present study was conducted to evaluate ecofriendly approaches by using a maize rhizosphere isolate of Pseudomonas fluorescens (Trev.) Mig. and its formulation to control ear rot disease and fumonisin accumulation, and also to study the capacity to promote growth and yield of maize. In vitro assays were conducted to test the efficacy of P. fluorescens as a seed treatment on seed germination, seedling vigour and also the incidence of F. verticillioides in different maize cultivars. The field trials included both seed treatment and foliar spray. For all the experiments, P. fluorescens was formulated using corn starch, wheat bran and talc powder. In each case there were three different treatments of P. fluorescens, a non-treated control and chemical control. Pure culture and the formulations, in comparison with the control, increased plant growth and vigour as measured by seed germination, seedling vigour, plant height, 1000 seed weight and yield. P. fluorescens pure culture used as seed treatment and as spray treatment enhanced the growth parameters and reduced the incidence of F. verticillioides and the level of fumonisins to a maximum extent compared with the other treatments. The study demonstrates the potential role of P. fluorescens and its formulations in ear rot disease management. The biocontrol potential of this isolate is more suited for fumonisin reduction in maize kernels intended for human and animal feed. (c) 2009 Society of Chemical Industry.

  18. Feasibility and acceptability of training community health workers in ear and hearing care in Malawi: a cluster randomised controlled trial.

    Science.gov (United States)

    Mulwafu, Wakisa; Kuper, Hannah; Viste, Asgaut; Goplen, Frederik K

    2017-10-11

    To assess the feasibility and acceptability of training community health workers (CHWs) in ear and hearing care, and their ability to identify patients with ear and hearing disorders. Cluster randomised controlled trial (RCT). Health centres in Thyolo district, Malawi. Ten health centres participated, 5 intervention (29 CHWs) and 5 control (28 CHWs). Intervention CHWs received 3 days of training in primary ear and hearing care, while among control CHWs, training was delayed for 6 months. Both groups were given a pretest that assessed knowledge about ear and hearing care, only the intervention group was given the posttest on the third day of training. The intervention group was given 1 month to identify patients with ear and hearing disorders in their communities, and these people were screened for hearing disorders by ear, nose and throat clinical specialists. Primary outcome measure was improvement in knowledge of ear and hearing care among CHWs after the training. Secondary outcome measures were number of patients with ear or hearing disorders identified by CHWs and number recorded at health centres during routine activities, and the perceived feasibility and acceptability of the intervention. The average overall correct answers increased from 55% to 68% (95% CI 65 to 71) in the intervention group (phearing disorders were identified by CHWs and 860 patients attended the screening camps, of whom 400 had hearing loss (73 patients determined through bilateral fail on otoacoustic emissions, 327 patients through audiometry). Where cause could be determined, the most common cause of ear and hearing disorders was chronic suppurative otitis media followed by impacted wax. The intervention was perceived as feasible and acceptable to implement. Training was effective in improving the knowledge of CHW in ear and hearing care in Malawi and allowing them to identify patients with ear and hearing disorders. This intervention could be scaled up to other CHWs in low-income and

  19. Ear wax

    Science.gov (United States)

    See your provider if your ears are blocked with wax and you are unable to remove the wax. Also call if you have an ear wax blockage and you develop new symptoms, such as: Drainage from the ear Ear pain Fever Hearing loss that continues after you clean the wax

  20. Ear Pieces

    Science.gov (United States)

    DiJulio, Betsy

    2011-01-01

    In this article, the author describes an art project wherein students make fanciful connections between art and medicine. This project challenges students to interpret "ear idioms" (e.g. "blow it out your ear," "in one ear and out the other") by relying almost entirely on realistic ear drawings, the placement of them, marks, and values. In that…

  1. Ear examination

    Science.gov (United States)

    ... may be present. The eardrum is a light-gray color or a shiny pearly-white. Light should ... discharge or bleeding Alternative Names Otoscopy Images Ear anatomy Medical findings based on ear anatomy Otoscopic exam ...

  2. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature

    Directory of Open Access Journals (Sweden)

    Ernesto Suaste-Gómez

    2016-03-01

    Full Text Available An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa and temperature (2 °C to 90 °C. The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing. More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  3. Experimental analysis of considering the sound pressure distribution pattern at the ear canal entrance as an unrevealed head-related localization clue

    Institute of Scientific and Technical Information of China (English)

    TONG Xin; QI Na; MENG Zihou

    2018-01-01

    By analyzing the differences between binaural recording and real listening,it was deduced that there were some unrevealed auditory localization clues,and the sound pressure distribution pattern at the entrance of ear canal was probably a clue.It was proved through the listening test that the unrevealed auditory localization clues really exist with the reduction to absurdity.And the effective frequency bands of the unrevealed localization clues were induced and summed.The result of finite element based simulations showed that the pressure distribution at the entrance of ear canal was non-uniform,and the pattern was related to the direction of sound source.And it was proved that the sound pressure distribution pattern at the entrance of the ear canal carried the sound source direction information and could be used as an unrevealed localization cluc.The frequency bands in which the sound pressure distribution patterns had significant differences between front and back sound source directions were roughly matched with the effective frequency bands of unrevealed localization clues obtained from the listening tests.To some extent,it supports the hypothesis that the sound pressure distribution pattern could be a kind of unrevealed auditory localization clues.

  4. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature.

    Science.gov (United States)

    Suaste-Gómez, Ernesto; Rodríguez-Roldán, Grissel; Reyes-Cruz, Héctor; Terán-Jiménez, Omar

    2016-03-04

    An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF) for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa) and temperature (2 °C to 90 °C). The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing). More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  5. Hydrostatic fluid pressure in the vestibular organ of the guinea pig

    NARCIS (Netherlands)

    Park, Jonas J. -H.; Boeven, Jahn J.; Vogel, Stefan; Leonhardt, Steffen; Wit, Hero P.; Westhofen, Martin

    Since inner ear hair cells are mechano-electric transducers the control of hydrostatic pressure in the inner ear is crucial. Most studies analyzing dynamics and regulation of inner ear hydrostatic pressure performed pressure measurements in the cochlea. The present study is the first one reporting

  6. Pressure Points: Preventing and Controlling Hypertension

    Science.gov (United States)

    ... Issue Past Issues Pressure Points: Preventing and Controlling Hypertension Past Issues / Summer 2006 Table of Contents For ... diagnosed with high blood pressure." Aditional Information On Hypertension MedlinePlus: High blood pressure: http://www.nlm.nih. ...

  7. Blood pressure in young adults with and without a paternal history of premature coronary heart disease in Europe: the EARS study. [European arteriosclerosis study

    NARCIS (Netherlands)

    Masana, L.; Farinaro, E.; Henauw, S. de; Nicaud, V.

    1996-01-01

    Objective : The European Arteriosclerosis Study (EARS) was designed to identify variables which discriminate subjects with a paternal history of premature coronary heart disease (CHD) from controls and to study the distribution of these variables across Europe. In this article we report on the blood

  8. Effect of a single session of ear acupuncture on pain intensity and postural control in individuals with chronic low back pain: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Andrea Ushinohama

    2016-01-01

    Full Text Available ABSTRACT Background Ear Acupuncture (EA is a form of acupuncture in which needles are applied to the external ear and has been used in multiple painful conditions. Low back pain (LBP is highly prevalent in active individuals and causes high economic burden to health systems worldwide. LBP affects the person’s ability to keep balance, especially in challenging conditions. Objective The aim of the study was to examine the effects of a single session of EA on pain intensity and body sway during postural tasks. Method Eighty adults with LBP and pain intensity equal to or greater than 4 (0-10 scale were randomly allocated (1:1 to EA group (EAG or placebo group (PG. Initially, the level of pain intensity was assessed. Next, participants stood still on a force plate either with feet in parallel or in semi-tandem and with eyes open or closed. Then, the EAG was treated with EA for 20 min and the PG was treated with detuned ultrasound. After the treatment, pain intensity was assessed again and the postural test was repeated. Pain intensity was the primary outcome and center of pressure sway area and speed were the secondary outcomes measured. Results Results revealed that pain intensity decreased in both groups after treatment, but decreased more in the EAG. For postural control, no effect of treatment and no interaction between treatment and postural condition on body sway were found. Conclusion Those findings indicate that EA is better than placebo to reduce pain, but neither treatment has any effect on postural control.

  9. Ear Acupuncture Therapy for Masticatory Myofascial and Temporomandibular Pain: A Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Luciano Ambrosio Ferreira

    2015-01-01

    Full Text Available Ear acupuncture works by reducing painful sensations with analgesic effect through microsystem therapy and has been demonstrated to be as effective as conventional therapies in the control of facial pain. This clinical trial aimed to evaluate the adjuvant action of auricular acupuncture through an observation of the evolution of temporomandibular and masticatory myofascial symptoms in two groups defined by the therapies elected: auricular acupuncture associated with occlusal splint (study and the use of the occlusal splint plate alone (control. We have selected 20 patients, who were randomly allocated into two groups of ten individuals. Symptoms were evaluated in five different moments, every seven days. We analyzed the orofacial muscle and joint palpation in order to measure the intensity of the experienced pain. Both groups showed a statistically significant decrease in muscle and joint symptoms (p<0.05. However, comparisons between the groups showed an expressive and significant reduction of symptomatology in the study group (p<0.05 already on the first week of therapy. According to the results, to the methodological criteria developed and statistical analysis applied, the conclusion is that auricular acupuncture therapy has synergistic action on conventional occlusal splint treatment. It was demonstrated to be effective in the reduction of symptoms in the short term.

  10. Essential oils on the control of stem and ear rot in maize

    Directory of Open Access Journals (Sweden)

    Glauco Antonio Teixeira

    2013-11-01

    Full Text Available Stem and ear rot caused by Stenocarpella maydis are responsible for severe losses in maize production. Treatment of seeds with fungicides may induce environmental damage. Hence, this study aimed to evaluate the effects of essential oils extracted from Cymbopogon winterianus, Thymus vulgaris, Cymbopogon citratus, Corymbia citriodora, Cinnamomum zeylanicum, and Syzygium aromaticum on the development of in vitro S. maydis. In addition, maize seeds were treated with these essential oils to determine their possible mode of action and effects. The oils from S. aromaticum, C. zeylanicum, and T. vulgaris inhibited fungal development at concentrations higher than 0.025%. The oils from S. aromaticum and C. zeylanicum showed seed germination rates of 89.0% and 84.5%, which were higher than that of the control. The oils from S. aromaticum and C. zeylanicum reduced the pathogen incidence in the seeds to 39.0% and 28.0%, respectively. Further, these oils as well as that from T. vulgaris produced lower reduction of maize stand. Scanning electron microscopy examination revealed that essential oils from S. aromaticum and T. vulgaris acted directly on the conidia, impeding germination. The findings suggest that the oils from S. aromaticum, C. zeylanicum, and T. vulgaris are potential alternatives for maize seed treatment in the control of S. maydis.

  11. Fuzzy control of pressurizer dynamic process

    International Nuclear Information System (INIS)

    Ming Zhedong; Zhao Fuyu

    2006-01-01

    Considering the characteristics of pressurizer dynamic process, the fuzzy control system that takes the advantages of both fuzzy controller and PID controller is designed for the dynamic process in pressurizer. The simulation results illustrate this type of composite control system is with better qualities than those of single fuzzy controller and single PID controller. (authors)

  12. A temperature and pressure controlled calibration system for pressure sensors

    Science.gov (United States)

    Chapman, John J.; Kahng, Seun K.

    1989-01-01

    A data acquisition and experiment control system capable of simulating temperatures from -184 to +220 C and pressures either absolute or differential from 0 to 344.74 kPa is developed to characterize silicon pressure sensor response to temperature and pressure. System software is described that includes sensor data acquisition, algorithms for numerically derived thermal offset and sensitivity correction, and operation of the environmental chamber and pressure standard. This system is shown to be capable of computer interfaced cryogenic testing to within 1 C and 34.47 Pa of single channel or multiplexed arrays of silicon pressure sensors.

  13. Your Ears

    Science.gov (United States)

    ... More on this topic for: Kids Can Loud Music Hurt My Ears? What Is an Ear Infection? Senses Experiment: Model Eardrum Going to the Audiologist What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  14. Ear Problems in Swimmers

    Directory of Open Access Journals (Sweden)

    Mao-Che Wang

    2005-08-01

    Full Text Available Acute diffuse otitis externa (swimmer's ear, otomycosis, exostoses, traumatic eardrum perforation, middle ear infection, and barotraumas of the inner ear are common problems in swimmers and people engaged in aqua activities. The most common ear problem in swimmers is acute diffuse otitis externa, with Pseudomonas aeruginosa being the most common pathogen. The symptoms are itching, otalgia, otorrhea, and conductive hearing loss. The treatment includes frequent cleansing of the ear canal, pain control, oral or topical medications, acidification of the ear canal, and control of predisposing factors. Swimming in polluted waters and ear-canal cleaning with cotton-tip applicators should be avoided. Exostoses are usually seen in people who swim in cold water and present with symptoms of accumulated debris, otorrhea and conductive hearing loss. The treatment for exostoses is transmeatal surgical removal of the tumors. Traumatic eardrum perforations may occur during water skiing or scuba diving and present with symptoms of hearing loss, otalgia, otorrhea, tinnitus and vertigo. Tympanoplasty might be needed if the perforations do not heal spontaneously. Patients with chronic otitis media with active drainage should avoid swimming, while patients who have undergone mastoidectomy and who have no cavity problems may swim. For children with ventilation tubes, surface swimming is safe in a clean, chlorinated swimming pool. Sudden sensorineural hearing loss and some degree of vertigo may occur after diving because of rupture of the round or oval window membrane.

  15. Ear acupuncture or local anaesthetics as pain relief during postpartum surgical repair: a randomised controlled trial

    DEFF Research Database (Denmark)

    Kindberg, S; Klünder, L; Strøm, J

    2009-01-01

    -hour hands-on training in the use of ear acupuncture. All midwives (n= 36) in the department had previous experience in using acupuncture for obstetric pain relief. Pain and wound healing were evaluated using validated scores. Data collection was performed by research assistants blinded towards...... treatment allocation. Randomisation was computer assisted. A total of 207 women were randomised to receive ear acupuncture (105) and local anaesthetics (102), respectively. Main outcome measures The primary outcome was pain during surgical repair. Secondary outcomes were wound healing at 24-48 hours and 14...... days postpartum, participant satisfaction, revision of wound or dyspareunia reported 6 months postpartum. Results Pain during surgical repair was more frequently reported by participants allocated to ear acupuncture compared with participants receiving local anaesthetics (89 versus 54%, P

  16. Nutraceuticals for blood pressure control.

    Science.gov (United States)

    Sirtori, Cesare R; Arnoldi, Anna; Cicero, Arrigo F G

    2015-01-01

    Significant effects on blood pressure (BP) have been reported from large nutritional interventions, particularly the Dietary Approaches to Stop Hypertension (DASH) and the Mediterranean diet. In more recent years, numerous studies have investigated the possible BP-lowering effect of different nutraceuticals; these range from specific foods to minerals, lipids, whole proteins, peptides, amino acids, probiotics, and vitamins. While a very large body of evidence supports the use of potassium, L-arginine, vitamins C and D, cocoa flavonoids, beetroot juice, some probiotics, coenzyme Q10, controlled-release melatonin, aged garlic extract, and coffee, the use of other nutraceuticals, such as green tea, flaxseed, and resveratrol, has not as yet been supported by adequate evidence. In some cases, e.g. proteins/peptides, the responsible component needs also to be fully uncovered. Finally, while for most of the products only short-term studies are available, with no specific end-points, an ongoing very large prospective study on chocolate flavanols will answer the question whether this may reduce cardiovascular risk. Thus, in addition to data on long-term safety, further clinical research is advisable in order to identify, among active nutraceuticals, those with the best cost-effectiveness and risk-benefit ratio for a wide use in the general population with a raised cardiovascular risk consequent to uncomplicated hypertension.

  17. Application of adaptive fuzzy control technology to pressure control of a pressurizer

    Institute of Scientific and Technical Information of China (English)

    YANG Ben-kun; BIAN Xin-qian; GUO Wei-lai

    2005-01-01

    A pressurizer is one of important equipment in a pressurized water reactor plant. It is used to maintain the pressure of primary coolant within allowed range because the sharp change of coolant pressure affects the security of reactor,therefor,the study of pressurizer's pressure control methods is very important. In this paper, an adaptive fuzzy controller is presented for pressure control of a pressurizer in a nuclear power plant. The controller can on-line tune fuzzy control rules and parameters by self-learning in the actual control process, which possesses the way of thinking like human to make a decision. The simulation results for a pressurized water reactor plant show that the adaptive fuzzy controller has optimum and intelligent characteristics, which prove the controller is effective.

  18. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ishida, Kazuo.

    1990-01-01

    Discharged water after actuating control rod drives in a BWR type reactor is once discharged to a discharging header, then returned to a master control unit and, subsequently, discharged to a reactor by way of a cooling water header. The radioactive level in the discharging header and the master control unit is increased by the reactor water to increase the operator's exposure. In view of the above, a riser is disposed for connecting a hydraulic pressure control unit incorporating a directional control valve and the cooling water head. When a certain control rod is inserted, the pressurized driving water is supplied through a hydraulic pressure control unit to the control rod drives. The discharged water from the control rod drives is entered by way of the hydraulic pressure control unit into the cooling water header and then returned to the reactor by way of other hydraulic pressure control unit and the control rod drives. Thus, the reactor water is no more recycled to the master control unit to reduce the radioactive exposure. (N.H.)

  19. Ear, Hearing and Speech

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2000-01-01

    An introduction is given to the the anatomy and the function of the ear, basic psychoacoustic matters (hearing threshold, loudness, masking), the speech signal and speech intelligibility. The lecture note is written for the course: Fundamentals of Acoustics and Noise Control (51001)......An introduction is given to the the anatomy and the function of the ear, basic psychoacoustic matters (hearing threshold, loudness, masking), the speech signal and speech intelligibility. The lecture note is written for the course: Fundamentals of Acoustics and Noise Control (51001)...

  20. Cosmetic ear surgery

    Science.gov (United States)

    Otoplasty; Ear pinning; Ear surgery - cosmetic; Ear reshaping; Pinnaplasty ... Cosmetic ear surgery may be done in the surgeon's office, an outpatient clinic, or a hospital. It can be performed under ...

  1. Intra- and Intersexual swim bladder dimorphisms in the plainfin midshipman fish (Porichthys notatus): Implications of swim bladder proximity to the inner ear for sound pressure detection.

    Science.gov (United States)

    Mohr, Robert A; Whitchurch, Elizabeth A; Anderson, Ryan D; Forlano, Paul M; Fay, Richard R; Ketten, Darlene R; Cox, Timothy C; Sisneros, Joseph A

    2017-11-01

    The plainfin midshipman fish, Porichthys notatus, is a nocturnal marine teleost that uses social acoustic signals for communication during the breeding season. Nesting type I males produce multiharmonic advertisement calls by contracting their swim bladder sonic muscles to attract females for courtship and spawning while subsequently attracting cuckholding type II males. Here, we report intra- and intersexual dimorphisms of the swim bladder in a vocal teleost fish and detail the swim bladder dimorphisms in the three sexual phenotypes (females, type I and II males) of plainfin midshipman fish. Micro-computerized tomography revealed that females and type II males have prominent, horn-like rostral swim bladder extensions that project toward the inner ear end organs (saccule, lagena, and utricle). The rostral swim bladder extensions were longer, and the distance between these swim bladder extensions and each inner-ear end organ type was significantly shorter in both females and type II males compared to that in type I males. Our results revealed that the normalized swim bladder length of females and type II males was longer than that in type I males while there was no difference in normalized swim bladder width among the three sexual phenotypes. We predict that these intrasexual and intersexual differences in swim bladder morphology among midshipman sexual phenotypes will afford greater sound pressure sensitivity and higher frequency detection in females and type II males and facilitate the detection and localization of conspecifics in shallow water environments, like those in which midshipman breed and nest. © 2017 Wiley Periodicals, Inc.

  2. Managing Stress to Control High Blood Pressure

    Science.gov (United States)

    ... Aortic Aneurysm More Managing Stress to Control High Blood Pressure Updated:Jan 29,2018 The importance of stress ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  3. Hydraulic pressure control unit for control rod drive

    International Nuclear Information System (INIS)

    Watabe, Yukio.

    1990-01-01

    The pressure invention concerns a hydraulic pressure control unit for control rod drives in BWR type reactors. The space above a floating piston possessed by an accumulator and the housing of control rod drives are connected by means of a pipeline. The pipeline has a scram valve which is opened upon occurrence of reactor scram. A pump is disposed between the accumulator and the scram valve for communicating a discharge port to apply a high pressure water to the accumulator. According to the present invention, a control unit is disposed between the scram valve and the housing of the control rod drives in the hydraulic pressure control unit for maintaining the cross sectional area of the flow channel of the pipeline to a usual size when the pressure in a pressure vessel is under a rated operation pressure, while limiting the cross sectional area of the flow channel when the pressure is lower than that in the rated operation. Thus, whole insertion of the control rod substantially at a constant speed is enabled irrespective of the level of the pressure in the pressure vessel. (I.S.)

  4. Hearing with an atympanic ear: good vibration and poor sound-pressure detection in the royal python, Python regius

    DEFF Research Database (Denmark)

    Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Brandt, Christian

    2012-01-01

    are sensitive to sound pressure and (2) snakes are sensitive to vibrations, but cannot hear the sound pressure per se. Vibration and sound-pressure sensitivities were quantified by measuring brainstem evoked potentials in 11 royal pythons, Python regius. Vibrograms and audiograms showed greatest sensitivity...... at low frequencies of 80-160 Hz, with sensitivities of -54 dB re. 1 m s(-2) and 78 dB re. 20 μPa, respectively. To investigate whether pythons detect sound pressure or sound-induced head vibrations, we measured the sound-induced head vibrations in three dimensions when snakes were exposed to sound...... pressure at threshold levels. In general, head vibrations induced by threshold-level sound pressure were equal to or greater than those induced by threshold-level vibrations, and therefore sound-pressure sensitivity can be explained by sound-induced head vibration. From this we conclude that pythons...

  5. Recipient government control under pressure

    DEFF Research Database (Denmark)

    Jansson, Johanna

    This paper seeks to contribute to ongoing debates around African countries‟ relations to their external partners. It explores the notion of recipient government control, here defined as the extent to which a recipient government is able to ensure that the outcome of negotiations with its external...... things, cited concerns for debt sustainability. The paper argues that in the early stages of negotiations with China during 2007-2008, the Congolese government exercised control in the sense that the 2008 version of the Sicomines agreement made sizeable amounts of funding available towards large...... relevance here, since it reduced its willingness to push ahead with the criticised version of the Sicomines agreement. Eventually, mid-2009, President Kabila accommodated the concerns of the traditional donors. The agreement was reduced and HIPC completion point was subsequently reached in July 2010...

  6. Control of Pressure Process Using Infineon Microcontroller

    Directory of Open Access Journals (Sweden)

    A. Siddique

    2007-07-01

    Full Text Available The main objective of this paper is to design a cost effective controller for real time implementation of pressure process using Infineon micro controller (SAB 80C517A. Model Identification is performed and it is found to be First Order Plus Dead Time Process (FOPDT. The performance measure is tabulated for different parameter and it is found that Proportional (P controller is suitable for controlling the process.

  7. Thermoelectric Control Of Temperatures Of Pressure Sensors

    Science.gov (United States)

    Burkett, Cecil G., Jr.; West, James W.; Hutchinson, Mark A.; Lawrence, Robert M.; Crum, James R.

    1995-01-01

    Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.

  8. Pressure control of hydraulic servo system using proportional control valve

    International Nuclear Information System (INIS)

    Yang, Kyong Uk; Oh, In Ho; Lee, Ill Yeong

    1999-01-01

    The purpose of this study is to develop a control scheme for the hydraulic servo system which can rapidly control the pressure in a hydraulic cylinder with very short stroke. Compared with the negligible stroke of the cylinder in the system, the flow gain of the proportional pressure control valve constituting the hydraulic servo system is relatively large and the time delay on the response of the valve is quite long. Therefore, the pressure control system, in this study tends to get unstable during operations. Considering the above mentioned characteristics of the system, a two-degree-of-freedom control scheme, composed of the I-PDD 2 ... feedback compensator and the feedforward controller, is proposed. The reference model scheme is used in deciding the parameters of the controllers. The validity of the proposed control scheme is confirmed through the experiments

  9. DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE

    Science.gov (United States)

    Bradner, H.; Gordon, H.S.

    1957-12-24

    A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.

  10. 76 FR 76085 - Revisions to the Export Administration Regulations (EAR): Control of Military Vehicles and...

    Science.gov (United States)

    2011-12-06

    ... systems to limit vehicle wiring; tire pressure monitoring systems; and data relating to tires (not including run-flats). Although these items might have to be modified for a particular military vehicle, such...

  11. Variable pattern contamination control under positive pressure

    International Nuclear Information System (INIS)

    Philippi, H.M.

    1997-01-01

    Airborne contamination control in nuclear and biological laboratories is traditionally achieved by directing the space ventilation air at subatmospheric pressures in one fixed flow pattern. However, biological and nuclear contamination flow control in the new Biological Research Facility, to be commissioned at the Chalk River Laboratories in 1996, will have the flexibility to institute a number of contamination control patterns, all achieved at positive (above atmospheric) pressures. This flexibility feature, made possible by means of a digitally controlled ventilation system, changes the facility ventilation system from being a relatively rigid building service operated by plant personnel into a flexible building service which can be operated by the facility research personnel. This paper focuses on and describes the application of these unique contamination control features in the design of the new Biological Research Facility. 3 refs., 7 figs

  12. Variable pattern contamination control under positive pressure

    Energy Technology Data Exchange (ETDEWEB)

    Philippi, H.M. [Chalk River Labs., Ontario (Canada)

    1997-08-01

    Airborne contamination control in nuclear and biological laboratories is traditionally achieved by directing the space ventilation air at subatmospheric pressures in one fixed flow pattern. However, biological and nuclear contamination flow control in the new Biological Research Facility, to be commissioned at the Chalk River Laboratories in 1996, will have the flexibility to institute a number of contamination control patterns, all achieved at positive (above atmospheric) pressures. This flexibility feature, made possible by means of a digitally controlled ventilation system, changes the facility ventilation system from being a relatively rigid building service operated by plant personnel into a flexible building service which can be operated by the facility research personnel. This paper focuses on and describes the application of these unique contamination control features in the design of the new Biological Research Facility. 3 refs., 7 figs.

  13. Dietary fiber and blood pressure control.

    Science.gov (United States)

    Aleixandre, A; Miguel, M

    2016-04-01

    In the past few years, new strategies to control blood pressure levels are emerging by developing new bioactive components of foods. Fiber has been linked to the prevention of a number of cardiovascular diseases and disorders. β-Glucan, the main soluble fiber component in oat grains, was initially linked to a reduction in plasma cholesterol. Several studies have shown afterward that dietary fiber may also improve glycaemia, insulin resistance and weight loss. The effect of dietary fiber on arterial blood pressure has been the subject of far fewer studies than its effect on the above-mentioned variables, but research has already shown that fiber intake can decrease arterial blood pressure in hypertensive rats. Moreover, certain fibers can improve arterial blood pressure when administered to hypertensive and pre-hypertensive subjects. The present review summarizes all those studies which attempt to establish the antihypertensive effects of dietary fiber, as well as its effect on other cardiovascular risk factors.

  14. Blood pressure control among type 2 diabetics

    International Nuclear Information System (INIS)

    Al-Shehri, Ahmed M.

    2008-01-01

    Objective was to assess blood pressure BP control in patients with diabetes mellitus type 2 DM type treated in primary health care. A cross-sectional study was conducted in primary health care at King Fahd Military Complex Hospital in Dhahran, Kingdom of Saudi Arabia, between August 2003 and February 2004, to assess blood control in type 2 diabetics. A sample of 403 medical records of type 2 diabetic patients was selected using systematic random sampling after ordering the medical record numbers. The data were collected through the pre-coded checklist. Hypertension was found in 57.8% of diabetic patients with no statistically significant difference between males and females. The mean age of diabetic patients was significantly highly in hypertensive than non-hypertensive p=0.001. The mean duration of hypertension was significantly higher in females p=0.02. There were only 14.2% of hypertensive diabetic patients in whom blood pressure was controlled. Poor control was significantly associated with obesity and a high rate of complications. Blood pressure control correlated positively and significantly with the age of patients and negatively with duration of diabetes and hypertension. The most commonly prescribed antihypertensive were angiotensin converting enzyme inhibitors in 29.3%, followed by angiotensin receptors blockers in 24.1%, and the least prescribed drug was thiazide diuretic. Blood pressure in diabetic patients needs to be given particular attention from all health care professionals, especially primary care family physicians, who should follow the new guideline for better control of blood pressure, and fewer complications. Patient's awareness should be increased, through continuous health education with different modalities. (author)

  15. Internally Coupled Ears in Living Mammals

    OpenAIRE

    Mason, Matthew James

    2015-01-01

    It is generally held that the right and left middle ears of mammals are acoustically isolated from each other, such that mammals must rely on neural computation to derive sound localisation cues. There are, however, some unusual species in which the middle ear cavities intercommunicate, in which case each ear might be able to act as a pressure-difference receiver. This could improve sound localisation at lower frequencies. The platypus Ornithorhynchus is apparently unique among mammals in tha...

  16. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ogawa, Masahide.

    1993-01-01

    The present invention concerns a control rod driving hydraulic device of a BWR type reactor, and provides an improvement for a means for supplying mechanical seal flashing water of a pump. That is, a mechanical seal flashing pipeline is branched at the downstream of a pressure-reducing orifice and connected to a minimum flow pipeline. With such a constitution, the minimum flow pipeline is connected to a minimum flow pipeline of an auxiliary pump at the downstream of the pressure-reducing orifice and returned to a suction pipeline of the pump. Pressure at the downstream of the pressure-reducing orifice is set, in the orifice, to a pressure required for mechanical seal flashing. Accordingly, the mechanical seal flashing pipeline is connected and a part of minimum flow rate is utilized, thereby enabling to cool mechanical seals. As a result, flow rate of the mechanical flashing water which has been flown out can be saved. The exhaustion amount from the pump can be reduced, to decrease the shaft power and reduce the capacity of the motor. (I.S.)

  17. 77 FR 35310 - Revisions to the Export Administration Regulations (EAR): Control of Military Training Equipment...

    Science.gov (United States)

    2012-06-13

    ... for foreign made ``military commodities'' that incorporate more than 10% U.S.-origin ``600 series... Military Training Equipment and Related Items the President Determines No Longer Warrant Control Under the... longer warrant control under Category IX (Military Training Equipment and Training) of the United States...

  18. 77 FR 25932 - Revisions to the Export Administration Regulations (EAR): Control of Energetic Materials and...

    Science.gov (United States)

    2012-05-02

    ... 1B608 that is ``specially designed'' for the ``production'' of rocket propellants; oxidizers or mixtures... would control equipment for the ``production'' of explosives and solid propellants, currently controlled...), this rule would move ``equipment'' for the ``production'' of explosives and solid propellants...

  19. Play it by Ear

    DEFF Research Database (Denmark)

    Kammersgaard, Nikolaj Peter Iversen; Kvist, Søren Helstrup; Thaysen, Jesper

    2014-01-01

    The first antenna for ear-to-ear communication with a standard Bluetooth chip has the potential to improve hearing aid technology.......The first antenna for ear-to-ear communication with a standard Bluetooth chip has the potential to improve hearing aid technology....

  20. 77 FR 22191 - Revisions to the Export Administration Regulations (EAR): Export Control Classification Number...

    Science.gov (United States)

    2012-04-13

    ..., Director, Office of National Security and Technology Transfer Controls, by phone at (202) 482-0092 or by... Administrative practice and procedure, Exports, Inventions and patents, Research science and technology. 15 CFR...

  1. 78 FR 45026 - Revisions to the Export Administration Regulations (EAR): Control of Military Electronic...

    Science.gov (United States)

    2013-07-25

    ... ECCN 3A611.c and .d should cover microwave monolithic integrated circuits and discrete microwave... and are not controlled. One commenter noted that placing monolithic microware integrated circuit power...: One commenter recommended removing the technical parameters for microwave monolithic integrated...

  2. 76 FR 80291 - Revisions to the Export Administration Regulations (EAR): Control of Submersible Vessels...

    Science.gov (United States)

    2011-12-23

    ... rule and to avoid, to the extent possible, situations where transactions would require licenses from... align the CCL with the WAML and the Missile Technology Control Regime Equipment, Software and Technology..., which currently impose a license requirement for five countries. A license also would be required, in...

  3. [Effect of ear point embedding on plasma and effect site concentrations of propofol-remifentanil in elderly patients after target-controlled induction].

    Science.gov (United States)

    Zheng, Xiaochun; Wan, Liling; Gao, Fei; Chen, Jianghu; Tu, Wenshao

    2017-08-12

    To observe the clinical effect of ear point embedding on plasma and effect site concentrations of propofol-remifentanil in elderly patients who underwent abdominal external hernia surgery at the time of consciousness and pain disappearing by target-controlled infusion (TCI) and bispectral index (BIS). Fifty patients who underwent elective abdominal hernia surgery were randomly assigned into an observation group and a control group, 25 cases in each one. In the observation group, 30 minutes before anesthesia induction, Fugugou (Extra), Gan (CO 12 ), Pizhixia (AT 4 ), and Shenmen (TF 4 ) were embedded by auricular needles until the end of surgery, 10 times of counter press each point. In the control group, the same amount of auricular tape was applied until the end of surgery at the same points without stimulation 30 minutes before anesthesia induction. Patients in the two groups were given total intravenous anesthesia, and BIS was monitored by BIS anesthesia depth monitor. Propofol was infused by TCI at a beginning concentration of 1.5μg/L and increased by 0.3μg/L every 30s until the patients lost their consciousness. After that, remifentanil was infused by TCI at a beginning concentration of 2.0μg/L and increased by 0.3μg/L every 30s until the patients had no body reaction to pain stimulation (orbital reflex). Indices were recorded, including mean arterial pressure (MAP), heart rate (HR) and the BIS values, at the time of T 0 (entering into the operation room), T 1 (losing consciousness) and T 2 (pain relief), the plasma and effect site concentrations of propofol at T 1 , the plasma and effect site concentrations of remifentanil at T 2 . After surgery we recorded the total amounts of propofol and remifentanil, surgery time and anesthesia time. At T 1 and T 2 , MAP and HR of the observation group were higher than those of the control group ( P effect site concentrations of propofol in the observation group were significantly lower than those in the control group

  4. Improving Blood Pressure Control Using Smart Technology.

    Science.gov (United States)

    Ciemins, Elizabeth L; Arora, Anupama; Coombs, Nicholas C; Holloway, Barbara; Mullette, Elizabeth J; Garland, Robin; Walsh Bishop-Green, Shannon; Penso, Jerry; Coon, Patricia J

    2018-03-01

    The authors sought to determine if wireless oscillometric home blood pressure monitoring (HBPM) that integrates with smartphone technology improves blood pressure (BP) control among patients with new or existing uncontrolled hypertension (HTN). A prospective observational cohort study monitored BP control before and after an educational intervention and introduction to HBPM. Patients in the intervention group were instructed to track their BP using a smartphone device three to seven times per week. Cases were matched to controls at a 1:3 allocation ratio on several clinical characteristics over the same period and received usual care. The proportion of patients with controlled BP was compared between groups at pre- and postintervention, ∼9 months later. Results and Materials: The total study population included 484 patients with mean age 60 years (range 23-102 years), 47.7% female, and 84.6% Caucasian. Mean preintervention BP was 137.8 mm Hg systolic and 81.4 mm Hg diastolic. Mean BP control rates improved for patients who received HBPM from 42% to 67% compared with matched control patients who improved from 59% to 67% (p technology has the potential to improve HTN management among patients with uncontrolled or newly diagnosed HTN. Technology needs to be easy to use and operate and would work best when integrated into local electronic health record systems. In systems without this capability, medical assistants or other personnel may be trained to facilitate the process. Nurse navigator involvement was instrumental in bridging communication between the patients and provider.

  5. Arc pressure control in GTA welding

    International Nuclear Information System (INIS)

    Cook, G.E.; Wells, F.M.; Levick, P.C.

    1986-01-01

    Relationships are established between the peak current of a pulsed, rectangular current waveform and the pulse current duty cycle under conditions of constant arc power. By appropriate choice of these interrelated parameters, it is shown that the arc pressure may be varied over a wide range even though the arc power is held constant. The methodology is suggested as a means of countering the effect of gravity in 5-G welding, while maintaining constant heat input to the weld. Combined with appropriate penetration sensors, the methodology is additionally suggested as a means of controlling penetration

  6. Ear Disorders in Scuba Divers

    Directory of Open Access Journals (Sweden)

    MH Azizi

    2010-12-01

    Full Text Available History of underwater diving dates back to antiquity. Breath-hold technique in diving was known to the ancient nations. However, deep diving progressed only in the early decades of the 19th century as the result of advancements in efficient underwater technologies which subsequently led to invention of sophisticated sets of scuba diving in the 20th century. Currently, diving is performed for various purposes including commercial, recreational, military, underwater construction, oil industry, underwater archeology and scientific assessment of marine life. By increasing popularity of underwater diving, dive-related medical conditions gradually became more evident and created a new challenge for the health care professionals, so that eventually, a specialty the so-called “diving medicine” was established. Most of the diving-associated disorders appear in the head and neck. The most common of all occupational disorders associated with diving are otologic diseases. External otitis has been reported as the most common otolaryngologic problem in underwater divers. Exostosis of the external ear canal may be formed in divers as the result of prolonged diving in cold waters. Other disorders of the ear and paranasal sinuses in underwater divers are caused by barometric pressure change (i.e., barotraumas, and to a lesser extent by decompression sickness. Barotrauma of the middle ear is the most prevalent barotrauma in divers. The inner ear barotraumas, though important, is less common. The present paper is a brief overview of diving-related ear disorders particularly in scuba divers.

  7. [Diagnostic value of high-resolution computed tomography imaging in congenital inner ear malformations].

    Science.gov (United States)

    Sun, Xiaowei; Ding, Yuanping; Zhang, Jianji; Chen, Ying; Xu, Anting; Dou, Fenfen; Zhang, Zihe

    2007-02-01

    To observe the inner ear structure with volume rendering (VR) reconstruction and to evaluate the role of high-resolution computed tomography (HRCT) in congenital inner ear malformations. HRCT scanning was performed in 10 patients (20 ears) without ear disease (control group) and 7 patients (11 ears) with inner ear malformations (IEM group) and the original data was processed with VR reconstruction. The inner ear osseous labyrinth structure in the images generated by these techniques was observed respectively in the normal ears and malformation ears. The inner ear osseous labyrinth structure and the relationship was displayed clearly in VR imaging in the control group,meanwhile, characters and degree of malformed structure were also displayed clearly in the IEA group. Of seven patients (11 ears) with congenital inner ear malformations, the axial, MPR and VR images can display the site and degree in 9 ears. VR images were superior to the axial images in displaying the malformations in 2 ears with the small lateral semicircular canal malformations. The malformations included Mondini deformity (7 ears), vestibular and semicircular canal malformations (3 ears), vestibular aqueduct dilate (7 ears, of which 6 ears accompanied by other malformations) , the internal auditory canal malformation (2 ears, all accompanied by other malformations). HRCT can display the normal structure of bone inner ear through high quality VR reconstructions. VR images can also display the site and degree of the malformations three-dimensionally and intuitively. HRCT is valuable in diagnosing the inner ear malformation.

  8. Ear Infection and Vaccines

    Science.gov (United States)

    ... an ENT Doctor Near You Ear Infection and Vaccines Ear Infection and Vaccines Patient Health Information News ... or may need reinsertion over time. What about vaccines? A vaccine is a preparation administered to stimulate ...

  9. Swimmer's Ear (For Parents)

    Science.gov (United States)

    ... Development Infections Diseases & Conditions Pregnancy & Baby Nutrition & Fitness Emotions & Behavior School & Family Life First Aid & Safety Doctors & ... can lead to an infection. Dry skin or eczema , scratching the ear canal, vigorous ear cleaning with ...

  10. Taking Care of Your Ears

    Science.gov (United States)

    ... Audiologist Perforated Eardrum What's Hearing Loss? Can Loud Music Hurt My Ears? What Is an Ear Infection? Swimmer's Ear Your Ears What's Earwax? View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  11. Water pressure control device for control rod drive

    International Nuclear Information System (INIS)

    Sato, Hideyuki.

    1981-01-01

    Purpose: To minimize the fluctuations in the reactor water level upon occurrence of abnormality by inputting the level signal of the reactor to an arithmetic unit for controlling the pressure of control rod drive water to thereby enable effective reactor level control. Constitution: Signal from a flow rate transmitter is inputted into an arithmetic unit to perform constant flow rate control upon normal operation. While on the other hand, if abnormality occurs such as feedwater pump trips, the arithmetic unit is switched from the constant flow rate control to the reactor water level control. Reactor water level signal is inputted into the arithmetic unit and the control valve is most suitably controlled, whereby water is fed from CST to the reactor by way of control rod drive water system to secure the reactor water level if feedwater to the reactor is interrupted by loss of coolants on the feedwater system. Since this enables to minimize the fluctuations in the reactor water level upon abnormality, the reactor water level can be controlled most suitably by the reactor water level signal. (Moriyama, K.)

  12. Sub-clinical middle ear malfunctions in elderly patients; prevalence ...

    African Journals Online (AJOL)

    ... absent acoustic reflex. Keywords: Middle ear malfunctions, elderly patients. ... hearing loss, had audiometric changes suggestive of such. We regarded such .... predictors of silent middle ear malfunction (control for Age and Sex). Variable.

  13. Modeling, Parameters Identification, and Control of High Pressure Fuel Cell Back-Pressure Valve

    Directory of Open Access Journals (Sweden)

    Fengxiang Chen

    2014-01-01

    Full Text Available The reactant pressure is crucial to the efficiency and lifespan of a high pressure PEMFC engine. This paper analyses a regulated back-pressure valve (BPV for the cathode outlet flow in a high pressure PEMFC engine, which can achieve precisely pressure control. The modeling, parameters identification, and nonlinear controller design of a BPV system are considered. The identified parameters are used in designing active disturbance rejection controller (ADRC. Simulations and extensive experiments are conducted with the xPC Target and show that the proposed controller can not only achieve good dynamic and static performance but also have strong robustness against parameters’ disturbance and external disturbance.

  14. Fuzzy control applied to nuclear power plant pressurizer system

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Mauro V.; Almeida, Jose C.S., E-mail: mvitor@ien.gov.b, E-mail: jcsa@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    In a pressurized water reactor (PWR) nuclear power plants (NPPs) the pressure control in the primary loop is very important for keeping the reactor in a safety condition and improve the generation process efficiency. The main component responsible for this task is the pressurizer. The pressurizer pressure control system (PPCS) utilizes heaters and spray valves to maintain the pressure within an operating band during steady state conditions, and limits the pressure changes, during transient conditions. Relief and safety valves provide overpressure protection for the reactor coolant system (RCS) to ensure system integrity. Various protective reactor trips are generated if the system parameters exceed safe bounds. Historically, a proportional-integral derivative (PID) controller is used in PWRs to keep the pressure in the set point, during those operation conditions. The purpose of this study has two main goals: first is to develop a pressurizer model based on artificial neural networks (ANNs); second is to develop a fuzzy controller for the PWR pressurizer pressure, and compare its performance with the P controller. Data from a simulator PWR plant was used to test the ANN and the controllers as well. The reference simulator is a Westinghouse 3-loop PWR plant with a total thermal output of 2785 MWth. The simulation results show that the pressurizer ANN model response are in reasonable agreement with the simulated power plant, and the fuzzy controller built in this study has better performance compared to the P controller. (author)

  15. Fuzzy control applied to nuclear power plant pressurizer system

    International Nuclear Information System (INIS)

    Oliveira, Mauro V.; Almeida, Jose C.S.

    2011-01-01

    In a pressurized water reactor (PWR) nuclear power plants (NPPs) the pressure control in the primary loop is very important for keeping the reactor in a safety condition and improve the generation process efficiency. The main component responsible for this task is the pressurizer. The pressurizer pressure control system (PPCS) utilizes heaters and spray valves to maintain the pressure within an operating band during steady state conditions, and limits the pressure changes, during transient conditions. Relief and safety valves provide overpressure protection for the reactor coolant system (RCS) to ensure system integrity. Various protective reactor trips are generated if the system parameters exceed safe bounds. Historically, a proportional-integral derivative (PID) controller is used in PWRs to keep the pressure in the set point, during those operation conditions. The purpose of this study has two main goals: first is to develop a pressurizer model based on artificial neural networks (ANNs); second is to develop a fuzzy controller for the PWR pressurizer pressure, and compare its performance with the P controller. Data from a simulator PWR plant was used to test the ANN and the controllers as well. The reference simulator is a Westinghouse 3-loop PWR plant with a total thermal output of 2785 MWth. The simulation results show that the pressurizer ANN model response are in reasonable agreement with the simulated power plant, and the fuzzy controller built in this study has better performance compared to the P controller. (author)

  16. Custom Made Pressure Appliance for Presurgical Sustained ...

    African Journals Online (AJOL)

    Among the most common complications of this therapy is ulceration due to excessive pressure. A case of presurgical size reduction for a large ear keloid with a custom made pressure appliance is presented. This novel design of the appliance allows for better control over the amount and direction of the pressure applied on ...

  17. [Risk factors for inner ear diseases].

    Science.gov (United States)

    Doroszewska, G; Kaźmierczak, H; Doroszewski, W

    2000-11-01

    The aim of this study was to evaluate the occurrence of obesity and arterial hypertension in patients suffering from vertigo, and/or tinnitus and/or hearing loss of unknown origin. 48 patients (25 women and 23 men) were included into this study. All patients had a negative previous medical history of any metabolic, cardiovascular or neurological disorders. Our results were compared to the control group of 31 healthy persons (16 women and 15 men). All subjects had a complete neurootologic examination, appropriate audiometric and vestibular studies. In most cases inner ear pathology was recognised. BMI, systolic and diastolic blood pressure were measured in all cases. Patients were overweight significantly more often comparing to the control group. Systolic and diastolic hypertension was found significantly more often in men from the patients than control group.

  18. the effect of cd4 count level on the middle ear dynamics of hiv

    African Journals Online (AJOL)

    2014-01-01

    Jan 1, 2014 ... THE EFFECT OF CD4 COUNT LEVEL ON THE MIDDLE EAR DYNAMICS OF HIV INFECTED PATIENTS .... compliance and pressure values were the ones causing ... of sound wave than in the control group (non-HIV infected ...

  19. Fuzzy Control of Tidal volume, Respiration number and Pressure value

    OpenAIRE

    Hasan Guler; Fikret Ata

    2010-01-01

    In this study, control of tidal volume, respiration number and pressure value which are arrived to patient at mechanical ventilator device which is used in intensive care units were performed with fuzzy logic controller. The aim of this system is to reduce workload of aneshesiologist. By calculating tidal volume, respiration number and pressure value, the error Pe(k) between reference pressure value (Pref) and pressure of gas given ill person (Phasta) and error change rate ;#948;Pe(k) were co...

  20. Heating tar sands formations while controlling pressure

    Science.gov (United States)

    Stegemeier, George Leo [Houston, TX; Beer, Gary Lee [Houston, TX; Zhang, Etuan [Houston, TX

    2010-01-12

    Methods for treating a tar sands formation are described herein. Methods may include heating at least a section of a hydrocarbon layer in the formation from a plurality of heaters located in the formation. A pressure in the majority of the section may be maintained below a fracture pressure of the formation. The pressure in the majority of the section may be reduced to a selected pressure after the average temperature reaches a temperature that is above 240.degree. C. and is at or below pyrolysis temperatures of hydrocarbons in the section. At least some hydrocarbon fluids may be produced from the formation.

  1. Pressure control device in a BWR type reactor

    International Nuclear Information System (INIS)

    Nagata, Yoshifumi.

    1983-01-01

    Purpose: To perform an adequate pressure control with no erroneous scram operation even when the balance of pressure is lost between main steam pipelines. Constitution: Pressure detectors are disposed respectively to a plurality of main steam pipelines and pressure detection values therefrom are inputted into a higher value preference circuit to select a higher value. The deviation between the higher pressure value signal and an aimed value is calculated in an addition circuit and the calculated deviation is inputted to a succeeding higher value preference circuit by way of a servo mechanism as an output from an electronic main steam pressure controller. The above output and the output from another mechanical main steam pressure controller are compared in this circuit to issue a higher value signal to a governer to control the degree of a steam control valve by way of the governor and the servo mechanism. The deviation hereinafter is converged through the same procedures into an aimed predetermined value. (Sekiya, K.)

  2. Control of superplastic cavitation by hydrostatic pressure

    International Nuclear Information System (INIS)

    Bampton, C.C.; Ghosh, A.K.; Hamilton, C.H.; Mahoney, M.W.; Raj, R.

    1983-01-01

    It has been shown that the application of hydrostatic gas pressures during superplastic deformation of fine grained 7475 Al can prevent the intergranular cavitation normally encountered at atmospheric pressure. A critical ratio of hydrostatic pressure to flow stress may be defined for each superplastic forming condition above which virtually no cavitation occurs. In deformation conditions where intergranular cavitation plays a significant part in final tensile rupture, superplastic ductility may be improved by the application of hydrostatic pressures. Similarly, detrimental effects of large superplastic strains on service properties may be reduced or eliminated by the application of suitable hydrostatic pressures during superplastic forming. In this case, superplastically formed material may have the same design allowables as conventional 7475 Al sheet

  3. Cardiovascular Topics Blood pressure control at a hospital day clinic ...

    African Journals Online (AJOL)

    1999-02-01

    Feb 1, 1999 ... control in a hospital day clinic population receiving cal- cium channel ... we had showed poor control of blood pressure in this hospital-based population .... Assessment of com- .... Program are obering: 19 almost half of newly treated hyper- tensives will di ... blood pressure control and quality of life. There is ...

  4. Quality Management and Control of Low Pressure Cast Aluminum Alloy

    Science.gov (United States)

    Zhang, Dianxi; Zhang, Yanbo; Yang, Xiufan; Chen, Zhaosong; Jiang, Zelan

    2018-01-01

    This paper briefly reviews the history of low pressure casting and summarizes the major production processes of low pressure casting. It briefly introduces the quality management and control of low pressure cast aluminum alloy. The main processes include are: preparation of raw materials, Melting, refining, physical and chemical analysis, K-mode inspection, sand core, mold, heat treatment and so on.

  5. Pressure mapping to prevent pressure ulcers in a hospital setting: A pragmatic randomised controlled trial.

    Science.gov (United States)

    Gunningberg, Lena; Sedin, Inga-Maj; Andersson, Sara; Pingel, Ronnie

    2017-07-01

    Pressure ulcers cause suffering to patients and costs to society. Reducing pressure at the interface between the patient's body and the support surface is a valid clinical intervention for reducing the risk of pressure ulcers. However, studies have shown that knowledge of how to reduce pressure and shear and to prevent pressure ulcers is lacking. To evaluate the effect of a pressure mapping system on pressure ulcer prevalence and incidence in a hospital setting. Pragmatic randomised controlled trial. A geriatric/internal medical ward with 26 beds in a Swedish university hospital. 190 patients were recruited (intervention: n=91; control: n=99) over a period of 9 months. Patients were eligible if they were over 50 years old, admitted to the ward between Sunday 4pm and Friday 4pm, and expected to stay in the ward ≥3 days. The continuous bedside pressure mapping system displays the patient's pressure points in real-time colour imagery showing how pressure is distributed at the body-mat interface. The system gives immediate feedback to staff about the patient's pressure points, facilitating preventive interventions related to repositioning. It was used from admittance to discharge from the ward (or 14 days at most). Both intervention and control groups received standard pressure ulcer prevention care. No significant difference in the prevalence and incidence of pressure ulcers was shown between intervention and control groups. The prevalence of pressure ulcers in the intervention group was 24.2% on day 1 and 28.2% on day 14. In the control group the corresponding numbers were 18.2% and 23.8%. Seven of 69 patients (10.1%) in the intervention group and seven of 81 patients (8.6%) in the control group who had no pressure ulcers on admission developed category 1 and category 2 ulcers during their hospital stay. The incidence rate ratio between the intervention and control groups was 1.13 (95% CI: 0.34-3.79). This study failed to demonstrate a beneficial effect of a

  6. Blood pressure and control of cardiovascular risk

    OpenAIRE

    Judith A Whitworth

    2005-01-01

    Judith A WhitworthJohn Curtin School of Medical Research, Australian National University, Canberra, ACT, AustraliaAbstract: Two key early 20th century notions, the first the primacy of diastolic pressure in determining risk, and the second that hypertension is a discrete disorder, have proved to be incorrect. We now recognize the primacy of systolic pressure as a risk factor for cardiovascular disease and that hypertension is an arbitrary definition. In the early 21st century, we are moving a...

  7. Hairy ears; Revisited

    Directory of Open Access Journals (Sweden)

    Daifullah Al Aboud

    2014-04-01

    Full Text Available Hair can grow in areas which are not usually hairy in human skin. The Online Mendelian Inheritance in Man (OMIM (http:// www.ncbi.nlm.nih.gov/omimhave some entries in this regards. These include ( %139600 – HAIRY ELBOWS, #605130 – HAIRY ELBOWS, SHORT STATURE, FACIAL DYSMORPHISM, AND DEVELOPMENTAL DELAY, 139630 – HAIRY NOSE TIP, 139500 – HAIRY EARS, and 425500 – HAIRY EARS, Y-LINKED. Hairy ears, (Fig. 1, are uncommon trait and it is rare to see a person with very long hair on the ears.

  8. Blood pressure and control of cardiovascular risk

    Directory of Open Access Journals (Sweden)

    Judith A Whitworth

    2005-10-01

    Full Text Available Judith A WhitworthJohn Curtin School of Medical Research, Australian National University, Canberra, ACT, AustraliaAbstract: Two key early 20th century notions, the first the primacy of diastolic pressure in determining risk, and the second that hypertension is a discrete disorder, have proved to be incorrect. We now recognize the primacy of systolic pressure as a risk factor for cardiovascular disease and that hypertension is an arbitrary definition. In the early 21st century, we are moving away from a dichotomous approach to risk classification, and away from notions of hypertension and normotension towards an appreciation that blood pressure-related risk is continuous. In parallel, there has been a paradigm shift from a single risk factor approach to comprehensive cardiovascular disease risk prevention. Accordingly, prevention of cardiovascular disease requires a focus on lowering of blood pressure and modification of associated risk factors rather than simply treatment of hypertension. This emphasis is reflected in the World Health Organization (WHO – International Society of Hypertension (ISH 2003 statement on management of hypertension.Keywords: blood pressure, hypertension, cardiovascular risk, treatment

  9. Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference

    Science.gov (United States)

    Bao, Xiaoqi (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor)

    2016-01-01

    A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.

  10. Pressure Control in Distillation Columns: A Model-Based Analysis

    DEFF Research Database (Denmark)

    Mauricio Iglesias, Miguel; Bisgaard, Thomas; Kristensen, Henrik

    2014-01-01

    A comprehensive assessment of pressure control in distillation columns is presented, including the consequences for composition control and energy consumption. Two types of representative control structures are modeled, analyzed, and benchmarked. A detailed simulation test, based on a real...... industrial distillation column, is used to assess the differences between the two control structures and to demonstrate the benefits of pressure control in the operation. In the second part of the article, a thermodynamic analysis is carried out to establish the influence of pressure on relative volatility...

  11. Anatomical influences on internally coupled ears in reptiles.

    Science.gov (United States)

    Young, Bruce A

    2016-10-01

    Many reptiles, and other vertebrates, have internally coupled ears in which a patent anatomical connection allows pressure waves generated by the displacement of one tympanic membrane to propagate (internally) through the head and, ultimately, influence the displacement of the contralateral tympanic membrane. The pattern of tympanic displacement caused by this internal coupling can give rise to novel sensory cues. The auditory mechanics of reptiles exhibit more anatomical variation than in any other vertebrate group. This variation includes structural features such as diverticula and septa, as well as coverings of the tympanic membrane. Many of these anatomical features would likely influence the functional significance of the internal coupling between the tympanic membranes. Several of the anatomical components of the reptilian internally coupled ear are under active motor control, suggesting that in some reptiles the auditory system may be more dynamic than previously recognized.

  12. A double-blind, placebo-controlled clinical trial of the effect of chlorpheniramine on the response of the nasal airway, middle ear and eustachian tube to provocative rhinovirus challenge.

    Science.gov (United States)

    Doyle, W J; McBride, T P; Skoner, D P; Maddern, B R; Gwaltney, J M; Uhrin, M

    1988-03-01

    This paper presents the results of a randomized, double-blind, placebo-controlled study of the efficacy of chlorpheniramine in relieving the symptoms and attenuating the pathophysiologic correlates of a rhinovirus "common cold." Forty healthy, adult, nonatopic subjects were randomly assigned to one of two treatment groups: active drug and placebo. On study Day 0, all subjects were challenged intranasally with rhinovirus type 39 (dose = 100 TCID50). Subjects were cloistered from Day 2 to Day 7, at which time they were treated with either chlorpheniramine or placebo. From 3 days before challenge to study Day 19, subjects had nasal patency assessed by rhinomanometry, eustachian tube function assessed by the 9-step test and sonotubometry, middle ear pressure assessed by tympanometry and nasal clearance assessed by the dyed-saccharin technique. Symptom diaries were maintained throughout the period of follow-up. During cloister, symptoms also were scored by interview, nasal secretions were quantified and nasal washings were performed for viral culture. Results showed that 19 (95%) subjects in the active-treatment group and 18 (90%) subjects in the placebo-treatment group shed virus. Symptomatic colds were observed in 63% of the active-treated and 83% of the placebo-treated subjects. Symptoms increased on Day 1 and peaked at Days 4 to 5. Detrimental changes in other measured functions consistent with those previously reported were observed. During the period of treatment, significant differences in the average symptom scores favoring the active-treatment group were observed for sneezing. Also, weight of expelled secretions was greater and mucociliary clearance rate less on some cloister days for the placebo-treated group. No significant differences between treatment groups in the objective measures of nasal congestion or the response of the middle ear and eustachian tube were documented.

  13. Nuclear power plant pressure vessels. Control of piping

    International Nuclear Information System (INIS)

    2000-01-01

    The guide presents requirements for the pipework of nuclear facilities in Finland. According to the section 117 of the Finnish Nuclear Energy Degree (161/88), the Radiation and Nuclear Safety Authority of Finland (STUK) controls the pressure vessels of nuclear facilities in accordance with the Nuclear Energy Act (990/87) and, to the extent applicable in accordance with the Act of Pressure Vessels (98/73) and the rules and regulations issued by the virtue of these. In addition STUK is an inspecting authority of pressure vessels of nuclear facilities in accordance with the Pressure Vessel Degree (549/1973). According to the section of the Pressure Vessel Degree, a pressure vessel is a steam boiler, pressure container, pipework of other such appliance in which the pressure is above or may come to exceed the atmospheric pressure. Guide YVL 3.0 describes in general terms how STUK controls pressure vessels. STUK controls Safety Class 1, 2 and 3 piping as well as Class EYT (non-nuclear) and their support structures in accordance with this guide and applies the provisions of the Decision of the Ministry of Trade and Industry on piping (71/1975) issued by virtue of the Pressure Vessel Decree

  14. 'Outrunning' the running ear

    African Journals Online (AJOL)

    Chantel

    In even the most experienced hands, an adequate physical examination of the ears can be difficult to perform because of common problems such as cerumen blockage of the auditory canal, an unco- operative toddler or an exasperated parent. The most common cause for a running ear in a child is acute purulent otitis.

  15. "Swimmer's Ear" (Otitis Externa) Prevention

    Science.gov (United States)

    ... infections, swimmer’s ear, and healthy swimming. "Swimmer's Ear" (Otitis Externa) What are the symptoms of swimmer's ear? ... Healthy page. Reference CDC. Estimated burden of acute otitis externa —United States, 2003–2007 . MMWR Morb Mortal ...

  16. High pressure common rail injection system modeling and control.

    Science.gov (United States)

    Wang, H P; Zheng, D; Tian, Y

    2016-07-01

    In this paper modeling and common-rail pressure control of high pressure common rail injection system (HPCRIS) is presented. The proposed mathematical model of high pressure common rail injection system which contains three sub-systems: high pressure pump sub-model, common rail sub-model and injector sub-model is a relative complicated nonlinear system. The mathematical model is validated by the software Matlab and a virtual detailed simulation environment. For the considered HPCRIS, an effective model free controller which is called Extended State Observer - based intelligent Proportional Integral (ESO-based iPI) controller is designed. And this proposed method is composed mainly of the referred ESO observer, and a time delay estimation based iPI controller. Finally, to demonstrate the performances of the proposed controller, the proposed ESO-based iPI controller is compared with a conventional PID controller and ADRC. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  17. [Deep needling and shallow needling at three acupoints around ear for subjective tinnitus: a randomized controlled trial].

    Science.gov (United States)

    Yin, Tao; Ni, Jinxia; Zhu, Wenzeng

    2015-10-01

    To compare the effective differences between deep needling and shallow needling at three acupoints around ear for subjective tinnitus. Fifty patients with subjective tinnitus were randomized divided into a deep needling group and a shallow needling group, 25 cases in each group. Twenty-two patients in the deep needling group and 20 patients in the shallow needling group were brought into statistic in the end. In the two groups, the three acupoints around ear and distal acupoints were both selected. The acupoints of the affected side such as Yifeng (TE 17), Tinghui (GB 2), Ermen (TE 21), Zhigou (TE 6), Zhongzhu (TE 3) and Hegu (LI 4) were adopted. Yifeng (TE 17), Tinghui (GB 2) and Ermen (TE 21) were acupunctured 30-38 mm in the deep needling group and 15-20 mm in the shallow needling group. The other acupoints were conventionally acupunctured in the two groups. The needles were retained for 30 min,once a day and five times a week for all patients. The treatment was continuously for 4 weeks in the two groups. Tinnitus handicap inventory (THI) scores, tinnitus grades and visual analogue scale (VAS) for tinnitus sound levels were observed before and after treatment, and the effects of the two groups were compared. The total effective rate in the deep needling group was 59.1% (13/22), and it was better than 20.0% (4/20) in the shallow needling group (P deep needling, group, the THI score, tinnitus grade and the VAS score were improved than those before treatment (all P shallow needling group, the three above indices before and after treatment were not different in statistical significance (all P > 0.05). After treatment, all the three indices in the deep needling group were superior to those in the shallow needling group (all P shallow needling at the three acupoints.

  18. Pressure-equalizing earplugs do not prevent barotrauma on descent from 8000 ft cabin altitude.

    Science.gov (United States)

    Klokker, Mads; Vesterhauge, Søren; Jansen, Erik C

    2005-11-01

    The aim of this study was to evaluate the effect of pressure-equalizing earplugs available in major airports and drugstores. No previous study has focused on preventing barotrauma using these earplugs. Blinded and double-blinded, one type of pressure-equalizing earplugs (JetEars) was studied in 27 volunteers disposed to ear barotrauma. They acted as their own controls with an active earplug in one ear and a placebo earplug in the other ear at random. All were exposed to the same well-defined pressure profile for 1 h at 8000 ft, comparable to the environment in civil commercial air travel in a pressurized cabin. Satisfaction was assessed by questionnaire and objective results were evaluated prior to and after the pressure exposure by tympanometry and otoscopy using the Teed classification. The majority of the volunteers (78%) reported a pleasant noise-reducing feeling using the earplugs. However, 75% also experienced ear pain during descent. In comparing the middle ear pressure before and after pressurization, a decrease was found in ears with both active earplugs and placebo earplugs. No difference between the active and the placebo earplugs were found. Furthermore, after evaluation of the two groups of ears using otoscopy, no prevention of barotrauma was found. In fact, the ears using an active pressure-equalizing earplug scored significantly worse (p = 0.033). Feelings of noise reduction were reported, but no prevention of barotrauma could be demonstrated with the use of pressure-equalizing earplugs. Pressure-equalizing earplugs cannot be recommended in air travel for preventing ear barotrauma.

  19. Blood Pressure Control: Stroke and Stroke Prevention

    Directory of Open Access Journals (Sweden)

    Hans-Christoph Diener

    2005-03-01

    Full Text Available Hypertension is the most important modifiable risk factor for primary and secondary stroke prevention.All antihypertensive drugs are effective in primary prevention: the risk reduction for stroke is 30—42%. However, not all classes of drugs have the same effects: there is some indication that angiotensin receptor blockers may be superior to other classes of antihypertensive drugs in stroke prevention.Seventy-five percent of patients who present to hospital with acute stroke have elevated blood pressure within the first 24—48 hours. Extremes of systolic blood pressure (SBP increase the risk of death or dependency. The aim of treatment should be to achieve and maintain the SBP in the range 140—160 mmHg. However, fast and drastic blood pressure lowering can have adverse consequences.The PROGRESS trial of secondary prevention with perindopril + indapamide versus placebo + placebo showed a decrease in numbers of stroke recurrences in patients given both active antihypertensive agents, more impressive for cerebral haemorrhage.There were also indications that active treatment might decrease the development of post-stroke dementia.

  20. Adaptive Reference Control for Pressure Management in Water Networks

    DEFF Research Database (Denmark)

    Kallesøe, Carsten; Jensen, Tom Nørgaard; Wisniewski, Rafal

    2015-01-01

    Water scarcity is an increasing problem worldwide and at the same time a huge amount of water is lost through leakages in the distribution network. It is well known that improved pressure control can lower the leakage problems. In this work water networks with a single pressure actuator and several....... Subsequently, these relations are exploited in an adaptive reference control scheme for the actuator pressure that ensures constant pressure at the critical points. Numerical experiments underpin the results. © Copyright IEEE - All rights reserved....

  1. Modeling low pressure baroreceptors and their contribution to blood pressure control

    OpenAIRE

    Sánchez de Zambrano, Betsy Mirley; Rojas-Sulbarán, Rubén Darío

    2016-01-01

    The main mechanism for blood pressure (BP) control is coordinated by the central nervous system through the sympathetic and parasympathetic systems. In order to simulate this mechanism, different mathematical models are available, but they take into account only the high pressure receptors as sensing systems for BP. However, other receptors located in low pressure areas have not, as far as we know, been considered in the models described in the literature, despite their important role in the ...

  2. The study and improvement of water level control of pressurizer

    International Nuclear Information System (INIS)

    Gao Peng; Zhang Qinshun

    2006-01-01

    The PI controller which is used widely in water level control of pressurizer in reactor control system usually leads dynamic overshoot and long setting time. The improvement project for intelligent fuzzy controller to take the place of PI controller is advanced. This paper researches the water level control of pressurizer in reactor control system of Daya Bay Phase I, and describes the method of intelligent fuzzy control in practice. Simulation indicates that the fuzzy control has advantages of small overshoot and short settling time. It can also improve control system's real time property and anti-interference ability. Especially for non-linear and time-varying complicated control systems, it can obtain good control results. (authors)

  3. Sterically controlled mechanochemistry under hydrostatic pressure

    Science.gov (United States)

    Yan, Hao; Yang, Fan; Pan, Ding; Lin, Yu; Hohman, J. Nathan; Solis-Ibarra, Diego; Li, Fei Hua; Dahl, Jeremy E. P.; Carlson, Robert M. K.; Tkachenko, Boryslav A.; Fokin, Andrey A.; Schreiner, Peter R.; Galli, Giulia; Mao, Wendy L.; Shen, Zhi-Xun; Melosh, Nicholas A.

    2018-02-01

    Mechanical stimuli can modify the energy landscape of chemical reactions and enable reaction pathways, offering a synthetic strategy that complements conventional chemistry. These mechanochemical mechanisms have been studied extensively in one-dimensional polymers under tensile stress using ring-opening and reorganization, polymer unzipping and disulfide reduction as model reactions. In these systems, the pulling force stretches chemical bonds, initiating the reaction. Additionally, it has been shown that forces orthogonal to the chemical bonds can alter the rate of bond dissociation. However, these bond activation mechanisms have not been possible under isotropic, compressive stress (that is, hydrostatic pressure). Here we show that mechanochemistry through isotropic compression is possible by molecularly engineering structures that can translate macroscopic isotropic stress into molecular-level anisotropic strain. We engineer molecules with mechanically heterogeneous components—a compressible (‘soft’) mechanophore and incompressible (‘hard’) ligands. In these ‘molecular anvils’, isotropic stress leads to relative motions of the rigid ligands, anisotropically deforming the compressible mechanophore and activating bonds. Conversely, rigid ligands in steric contact impede relative motion, blocking reactivity. We combine experiments and computations to demonstrate hydrostatic-pressure-driven redox reactions in metal-organic chalcogenides that incorporate molecular elements that have heterogeneous compressibility, in which bending of bond angles or shearing of adjacent chains activates the metal-chalcogen bonds, leading to the formation of the elemental metal. These results reveal an unexplored reaction mechanism and suggest possible strategies for high-specificity mechanosynthesis.

  4. Sliding pressure control valve for pneumatic hammer drill

    Science.gov (United States)

    Polsky, Yarom [Albuquerque, NM

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  5. How Potassium Can Help Control High Blood Pressure

    Science.gov (United States)

    ... Aneurysm More How Potassium Can Help Control High Blood Pressure Updated:Jan 29,2018 Understanding the heart-healthy ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  6. A system to control low pressure turbine temperatures

    International Nuclear Information System (INIS)

    1980-01-01

    An improved system to control low pressure turbine cycle steam and metal temperatures by governing the heat transfer operation in a moisture separator-reheater is described. The use of the present invention in a pressurized water reactor or a boiling water reactor steam turbine system is demonstrated. (UK)

  7. Temperature control for high pressure processes up to 1400 MPa

    International Nuclear Information System (INIS)

    Reineke, K; Mathys, A; Knorr, D; Heinz, V

    2008-01-01

    Pressure- assisted sterilisation is an emerging technology. Hydrostatic high pressure can reduce the thermal load of the product and this allows quality retention in food products. To guarantee the safety of the sterilisation process it is necessary to investigate inactivation kinetics especially of bacterial spores. A significant roll during the inactivation of microorganisms under high pressure has the thermodynamic effect of the adiabatic heating. To analyse the individual effect of pressure and temperature on microorganism inactivation an exact temperature control of the sample to reach ideal adiabatic conditions and isothermal dwell times is necessary. Hence a heating/cooling block for a high pressure unit (Stansted Mini-Food-lab; high pressure capillary with 300 μL sample volume) was constructed. Without temperature control the sample would be cooled down during pressure built up, because of the non-adiabatic heating of the steel made vessel. The heating/cooling block allows an ideal adiabatic heat up and cooling of the pressure vessel during compression and decompression. The high pressure unit has a pressure build-up rate up to 250 MPa s -1 and a maximum pressure of 1400 MPa. Sebacate acid was chosen as pressure transmitting medium because it had no phase shift over the investigate pressure and temperature range. To eliminate the temperature difference between sample and vessel during compression and decompression phase, the mathematical model of the adiabatic heating/cooling of water and sebacate acid was implemented into a computational routine, written in Test Point. The calculated temperature is the setpoint of the PID controller for the heating/cooling block. This software allows an online measurement of the pressure and temperature in the vessel and the temperature at the outer wall of the vessel. The accurate temperature control, including the model of the adiabatic heating opens up the possibility to realise an ideal adiabatic heating and cooling

  8. Simulation of static pressure reset control in comfort ventilation

    DEFF Research Database (Denmark)

    Koulani, Chrysanthi Sofia; Prunescu, Remus Mihail; Hviid, Christian Anker

    2014-01-01

    Variable air volume (VAV) ventilation systems reduce fan power consumption compared to constant air volume (CAV) systems because they supply air according to the airflow demand. However VAV ventilation systems do not take fully into account the potential energy savings as the control strategy...... management system. In this way the operation of central plant equipment is adjusted in real time according to the actual pressure demand; this control scheme can be implemented by the static pressure reset (SPR) method. The SPR control method ensures that at least one damper remains fully opened; thus...... of the art is represented by the method of trim and respond based on pressure alarms. This study investigates the operation of the SPR control method of trim and respond based on pressure alarms in a CO2 demand application where large air volumes are provided to three classrooms. The investigation was based...

  9. Socioeconomic and modifiable predictors of blood pressure control ...

    African Journals Online (AJOL)

    these clinics are nurse led, with varying levels of doctor involvement ... Patient and clinic factors influence blood pressure control and treatment in primary care clinics ..... role in study design, data collection and analysis, decision to publish, or.

  10. Simulation Analysis of Computer-Controlled pressurization for Mixture Ratio Control

    Science.gov (United States)

    Alexander, Leslie A.; Bishop-Behel, Karen; Benfield, Michael P. J.; Kelley, Anthony; Woodcock, Gordon R.

    2005-01-01

    A procedural code (C++) simulation was developed to investigate potentials for mixture ratio control of pressure-fed spacecraft rocket propulsion systems by measuring propellant flows, tank liquid quantities, or both, and using feedback from these measurements to adjust propellant tank pressures to set the correct operating mixture ratio for minimum propellant residuals. The pressurization system eliminated mechanical regulators in favor of a computer-controlled, servo- driven throttling valve. We found that a quasi-steady state simulation (pressure and flow transients in the pressurization systems resulting from changes in flow control valve position are ignored) is adequate for this purpose. Monte-Carlo methods are used to obtain simulated statistics on propellant depletion. Mixture ratio control algorithms based on proportional-integral-differential (PID) controller methods were developed. These algorithms actually set target tank pressures; the tank pressures are controlled by another PID controller. Simulation indicates this approach can provide reductions in residual propellants.

  11. External Otitis (Swimmer's Ear)

    Science.gov (United States)

    ... otitis. Fungal external otitis (otomycosis), typically caused by Aspergillus niger or Candida albicans, is less common. Boils are ... in the ear. Fungal external otitis caused by Aspergillus niger usually causes grayish black or yellow dots (called ...

  12. Ear Infections in Children

    Science.gov (United States)

    ... ear infections may get better without antibiotics. Using antibiotics cautiously and with good reason helps prevent the development of bacteria that become resistant to antibiotics. If your doctor prescribes an antibiotic, it’s important ...

  13. Maternal characteristics and birth outcomes of pregnant women who had offspring with congenital ear abnormalities - a population-based case-control study.

    Science.gov (United States)

    Paput, László; Bánhidy, Ferenc; Czeizel, Andrew E

    2011-09-01

    To describe the maternal characteristics and birth outcomes of newborn infants affected with isolated ear congenital abnormalities (IECA), mainly isolated anotia/microtia and unclassified multiple congenital abnormalities (CAs) including anotia/microtia (UMAM). Cases with IECA and UMAM were compared with their matched controls and all controls without any defect and malformed controls affected with other defects in the population-based large dataset of the Hungarian Case-Control Surveillance of Congenital Abnormalities. The mothers of 354 cases with IECA did not show significant difference in age, but their mean birth order was higher while their socio-economic status based on the maternal employment status was lower compared to the figures of their matched controls. There was a male excess among cases with microtia and mainly with UMAM. The evaluation of birth outcomes of newborns affected with IECA indicated intrauterine fetal growth retardation. Newborn infants with isolated microtia had intrauterine growth retardation and the association of this developmental defect localized for a small region of head with the general fetal development raises interesting theoretical question.

  14. Engine control system having pressure-based timing

    Science.gov (United States)

    Willi, Martin L [Dunlap, IL; Fiveland, Scott B [Metamora, IL; Montgomery, David T [Edelstein, IL; Gong, Weidong [Dunlap, IL

    2011-10-04

    A control system for an engine having a first cylinder and a second cylinder is disclosed having a first engine valve movable to regulate a fluid flow of the first cylinder and a first actuator associated with the first engine valve. The control system also has a second engine valve movable to regulate a fluid flow of the second cylinder and a sensor configured to generate a signal indicative of a pressure within the first cylinder. The control system also has a controller that is in communication with the first actuator and the sensor. The controller is configured to compare the pressure within the first cylinder with a desired pressure and selectively regulate the first actuator to adjust a timing of the first engine valve independently of the timing of the second engine valve based on the comparison.

  15. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    Science.gov (United States)

    Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there

  16. Randomised clinical trial of five ear acupuncture points for the treatment of overweight people.

    Science.gov (United States)

    Yeo, Sujung; Kim, Kang Sik; Lim, Sabina

    2014-04-01

    To evaluate the efficacy of the five ear acupuncture points (Shen-men, Spleen, Stomach, Hunger, Endocrine), generally used in Korean clinics for treating obesity, and compare them with the Hunger acupuncture point. A randomised controlled clinical trial was conducted in 91 Koreans (16 male and 75 female, body mass index (BMI)≥23), who had not received any other weight control treatment within the past 6 months. Subjects were divided randomly into treatment I, treatment II or sham control groups and received unilateral auricular acupuncture with indwelling needles replaced weekly for 8 weeks. Treatment I group received acupuncture at the five ear acupuncture points, treatment II group at the Hunger acupuncture point only and the sham control group received acupuncture at the five ear acupuncture points used in treatment I, but the needles were removed immediately after insertion. BMI, waist circumference, weight, body fat mass (BFM), percentage body fat and blood pressure were measured at baseline and at 4 and 8 weeks after treatment. For the 58 participants who provided data at 8 weeks, significant differences in BMI, weight and BFM were found between the treatment and control groups. Treatment groups I and II showed 6.1% and 5.7% reduction in BMI, respectively (pfive ear acupuncture points, generally used in Korean clinics, and the Hunger point alone treatment are both effective for treating overweight people.

  17. Capabilities of a New Pressure Controller for Gas-Controlled Heat Pipes

    Science.gov (United States)

    Giunta, S.; Merlone, A.; Marenco, S.; Marcarino, P.; Tiziani, A.

    2008-10-01

    Pressure control is used in many metrological applications and for the control of thermodynamic quantities. At the Italian National Research Institute of Metrology (INRiM), a new pressure controller has been designed and assembled, operating in the pressure range between 4 kPa and 400 kPa. This innovative instrument uses a commercial pressure transducer with a sensitivity of 10-4 and several electro-valves interposed among calibrated volumes of different dimensions in order to realize known ratios for very fine pressure changes. The device is provided with several circuits to drive the electro-valve actions, for signal processing and transmission, and for both manual and automatic control. Input/output peripherals, such as a 4 × 20 dot matrix display and a 4 × 4 keyboard, allow setting of the parameters and data visualization, while a remote control port allows interfacing with a computer. The operating principle of this pressure controller has been recently applied, with excellent results, to control the pressure in gas-controlled heat pipes by using a standard platinum resistance thermometer as a temperature/pressure sensor, achieving in this case a relative sensitivity better than 10-6 in pressure. Several tests were also made to control the pressure by means of a commercial sensor. The device, its main components, and its capabilities are here reported, together with application tests and results.

  18. Protective effect of unilateral and bilateral ear plugs on noise-induced hearing loss: Functional and morphological evaluation in animal model

    Directory of Open Access Journals (Sweden)

    Dong-Kee Kim

    2014-01-01

    Full Text Available The aim of the following study is to evaluate immediate protective effect of ear plug from noise morphologically and functionally. An 1-month aged 29 male C57BL/6 mice. Subjects were divided into four groups as normal control(G1, bilaterally plugged group (G2, unilaterally plugged group (G3 and noise control group (G4 and later 3 groups were exposed to 110 sound pressure level white noise for 60 min. Immediately after noise exposure, audiologic tests were performed and cochlear morphology and expression levels of a-synuclein in the cochlea were investigated. There were no functional changes in G2 and plugged ears of G3 after noise exposure, whereas unplugged ears of G3 and G4 showed significant hearing loss. In morphological study, there were a significant degeneration of the organ of Corti and mean number and diameter of efferent buttons, in unplugged ears of G3 and G4. Plugged ears of G3 also showed mild changes in morphological study. Reduction of a-synuclein was observed at the efferent terminals or cochlear extracts after noise exposure. The protective effect of ear plug on noise exposure was proven morphologically and functionally in the animal model of noise-induced hearing loss. Further study on cellular or ultrastructural level with ear plug will be needed to reveal more precise mechanism.

  19. Development of a Blood Pressure Measurement Instrument with Active Cuff Pressure Control Schemes

    Directory of Open Access Journals (Sweden)

    Chung-Hsien Kuo

    2017-01-01

    Full Text Available This paper presents an oscillometric blood pressure (BP measurement approach based on the active control schemes of cuff pressure. Compared with conventional electronic BP instruments, the novelty of the proposed BP measurement approach is to utilize a variable volume chamber which actively and stably alters the cuff pressure during inflating or deflating cycles. The variable volume chamber is operated with a closed-loop pressure control scheme, and it is activated by controlling the piston position of a single-acting cylinder driven by a screw motor. Therefore, the variable volume chamber could significantly eliminate the air turbulence disturbance during the air injection stage when compared to an air pump mechanism. Furthermore, the proposed active BP measurement approach is capable of measuring BP characteristics, including systolic blood pressure (SBP and diastolic blood pressure (DBP, during the inflating cycle. Two modes of air injection measurement (AIM and accurate dual-way measurement (ADM were proposed. According to the healthy subject experiment results, AIM reduced 34.21% and ADM reduced 15.78% of the measurement time when compared to a commercial BP monitor. Furthermore, the ADM performed much consistently (i.e., less standard deviation in the measurements when compared to a commercial BP monitor.

  20. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  1. Materials control and accounting (MC and A): the evolutionary pressures

    International Nuclear Information System (INIS)

    Shipley, J.P.

    1983-01-01

    Nuclear materials control and accounting systems are subject to pressures of both regulatory and institutional natures. This fact, coupled with the emergence of new technology, is causing evolutionary changes in materials control and accounting systems. These changes are the subject of this paper

  2. Antihypertensive regimen and blood pressure control in patients ...

    African Journals Online (AJOL)

    Hypertension is a major public health problem worldwide. In Nigeria, records have shown an increasing prevalence with suboptimal evaluation of blood pressure (BP) control. Generally, antihypertensives have recorded significant successes in BP control over the years. This study was aimed at investigating ...

  3. Application of improved quality control technology to pressure vessels

    International Nuclear Information System (INIS)

    Kriedt, F.

    1985-01-01

    Within the last decade, ASME Boiler and Pressure Vessel Code Section VIII-1 instituted requirements for a formal written quality control system. The results, good and bad, of this requirement are discussed. The effects are far reaching from a national economic standpoint. Quality control technology has improved. These improvements are discussed and compared to existing requirements of the CODE. Recommended improvements are suggested

  4. Modeling low pressure baroreceptors and their contribution to blood pressure control

    Directory of Open Access Journals (Sweden)

    Sánchez de Zambrano, Betsy Mirley

    2016-10-01

    Full Text Available The main mechanism for blood pressure (BP control is coordinated by the central nervous system through the sympathetic and parasympathetic systems. In order to simulate this mechanism, different mathematical models are available, but they take into account only the high pressure receptors as sensing systems for BP. However, other receptors located in low pressure areas have not, as far as we know, been considered in the models described in the literature, despite their important role in the nervous BP control. This paper presents a mathematical model for the representation of low pressure receptors by means of the detection of atrial volume changes, and their contribution to immediate BP control through nervous stimulation of the heart rate. The proposed model was coupled to the sensor mechanism of a larger model. With this model it is possible to analyze the contribution and behavior of low pressure receptors, thus allowing a better understanding of this complex system under normal and pathological conditions, since it includes important variables in the immediate BP control, not included in previous models.

  5. Pressure tracking control of vehicle ABS using piezo valve modulator

    Science.gov (United States)

    Jeon, Juncheol; Choi, Seung-Bok

    2011-03-01

    This paper presents a wheel slip control for the ABS(anti-lock brake system) of a passenger vehicle using a controllable piezo valve modulator. The ABS is designed to optimize for braking effectiveness and good steerability. As a first step, the principal design parameters of the piezo valve and pressure modulator are appropriately determined by considering the braking pressure variation during the ABS operation. The proposed piezo valve consists of a flapper, pneumatic circuit and a piezostack actuator. In order to get wide control range of the pressure, the pressure modulator is desired. The modulator consists of a dual-type cylinder filled with different substances (fluid and gas) and a piston rod moving vertical axis to transmit the force. Subsequently, a quarter car wheel slip model is formulated and integrated with the governing equation of the piezo valve modulator. A sliding mode controller to achieve the desired slip rate is then designed and implemented. Braking control performances such as brake pressure and slip rate are evaluated via computer simulations.

  6. Crystal size control of sulfathiazole using high pressure carbon dioxide

    Science.gov (United States)

    Kitamura, M.; Yamamoto, M.; Yoshinaga, Y.; Masuoka, H.

    1997-07-01

    The effect of the pressurization method of carbon dioxide on the crystallization behavior and crystal size of sulphathiazole (SUT) was investigated. In the "stepwise pressurization" method exceptionally large pillar-like crystals of 2-6 mm were obtained as mainly a scaling on the wall of the crystallizer. In the "rapid pressurization" method, crystals with a size one third to half of that obtained in the stepwise method precipitated, indicating the accelerated nucleation rate by the rapid increase of the supersaturation degree with a vigorous bubbling. With the new method of "two-step pressurization", in the first step the nucleation is accelerated with a much larger pressure instantly created, and in the second step the growth rate is retarded with the lower pressure. By this method much more fine crystals (from a few tens to several hundred micrometers) were produced and the scaling was suppressed. In this method a large supersaturation degree at an interface between the gas (bubble) and liquid phase under a vigorous bubbling may play an important role in accelerating the nucleation. The average size of the crystals tended to become smaller with increase of the first pressure and the expansion ratio at a decompression point, and it tended to get larger with increase of the second pressure. These results show that the GAS method is very useful for the control of crystal size over a wide range.

  7. Effects of nattokinase on blood pressure: a randomized, controlled trial.

    Science.gov (United States)

    Kim, Ji Young; Gum, Si Nae; Paik, Jean Kyung; Lim, Hyo Hee; Kim, Kyong-Chol; Ogasawara, Kazuya; Inoue, Kenichi; Park, Sungha; Jang, Yangsoo; Lee, Jong Ho

    2008-08-01

    The objective of this study was to examine the effects of nattokinase supplementation on blood pressure in subjects with pre-hypertension or stage 1 hypertension. In a randomized, double-blind, placebo-controlled trial, 86 participants ranging from 20 to 80 years of age with an initial untreated systolic blood pressure (SBP) of 130 to 159 mmHg received nattokinase (2,000 FU/capsule) or a placebo capsule for 8 weeks. Seventy-three subjects completed the protocol. Compared with the control group, the net changes in SBP and diastolic blood pressure (DBP) were -5.55 mmHg (95% confidence interval [CI], -10.5 to -0.57 mmHg; pnattokinase group compared with the control group (pnattokinase supplementation resulted in a reduction in SBP and DBP. These findings suggest that increased intake of nattokinase may play an important role in preventing and treating hypertension.

  8. HTGR power plant hot reheat steam pressure control system

    International Nuclear Information System (INIS)

    Braytenbah, A.S.; Jaegtnes, K.O.

    1975-01-01

    A control system for a high temperature gas cooled reactor (HTGR) power plant is disclosed wherein such plant includes a plurality of steam generators. Dual turbine-generators are connected to the common steam headers, a high pressure element of each turbine receiving steam from the main steam header, and an intermediate-low pressure element of each turbine receiving steam from the hot reheat header. Associated with each high pressure element is a bypass line connected between the main steam header and a cold reheat header, which is commonly connected to the high pressure element exhausts. A control system governs the flow of steam through the first and second bypass lines to provide for a desired minimum steam flow through the steam generator reheater sections at times when the total steam flow through the turbines is less than such minimum, and to regulate the hot reheat header steam pressure to improve control of the auxiliary steam turbines and thereby improve control of the reactor coolant gas flow, particularly following a turbine trip. (U.S.)

  9. Listening to the ear

    Science.gov (United States)

    Shera, Christopher A.

    Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics-termed "tapering symmetry" after its geometric interpretation in simple models-that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical

  10. 76 FR 80282 - Revisions to the Export Administration Regulations (EAR): Control of Vessels of War and Related...

    Science.gov (United States)

    2011-12-23

    ... would require licenses from both the State Department and the Commerce Department. Following the... further align the CCL with the WAML and the Missile Technology Control Regime Equipment, Software and... antiterrorism (AT Column 1) controls, which currently impose a license requirement for five countries. A license...

  11. A novel coordinated control for Integrated Pressurized Water Reactor

    International Nuclear Information System (INIS)

    Zhao, Yuxin; Du, Xue; Xia, Genglei; Gao, Feng

    2015-01-01

    Highlights: • Proposed IPWR coordinated control strategy to avoid flow instability of OTSG. • Tuned PID controller parameters by Fuzzy kernel wavelet neural network with kernel trick and adaptive variable step-size. • Transition process exhibit the effectiveness of the novel IPWR control system. - Abstract: Integrated Pressurized Water Reactor (IPWR) has the characteristic of strong coupling, nonlinearity and complicated dynamic performance, which requires high standards of the control strategy and controller design. Most of IPWR systems utilize control strategy of ideal steady-state and PID controller, even though this strategy causes flow instability in the once through steam generator (OTSG) in low load conditions. Besides, the simple form of PID limits the performance developing which could not appropriately satisfy the requirements for quality. Motivated by these drawbacks, this paper proposes an IPWR coordinated control strategy and adopts PID controller to control each subsystem. The control strategy considers the system as a two-level hierarchical control system, and considers coordinating controller and bottom controllers. In the period of controller design, this strategy utilizes PID controller to control each subsystem, and modifies the controller parameters in real time by Fuzzy-KWNN algorithm, which adaptively achieves the system adjustment. Finally, simulation results are presented to exhibit the effectiveness of the proposed IPWR control system

  12. A comparison of fuzzy logic-PID control strategies for PWR pressurizer control

    International Nuclear Information System (INIS)

    Kavaklioglu, K.; Ikonomopoulos, A.

    1993-01-01

    This paper describes the results obtained from a comparison performed between classical proportional-integral-derivative (PID) and fuzzy logic (FL) controlling the pressure in a pressurized water reactor (PWR). The two methodologies have been tested under various transient scenarios, and their performances are evaluated with respect to robustness and on-time response to external stimuli. One of the main concerns in the safe operation of PWR is the pressure control in the primary side of the system. In order to maintain the pressure in a PWR at the desired level, the pressurizer component equipped with sprayers, heaters, and safety relief valves is used. The control strategy in a Westinghouse PWR is implemented with a PID controller that initiates either the electric heaters or the sprayers, depending on the direction of the coolant pressure deviation from the setpoint

  13. Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential

    Science.gov (United States)

    Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.

  14. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...... in the transmission such as the earphone impedance. In order to determine the acoustic impedances of human ear canals, the standardized method for measurement of complex impedances used for the measurement of the audiometric earphone impedances is applied. It is based on the transfer function between two microphone...... locations in an impedance tube. The end of the tube representing the measurement plane is placed at the ear canal entrance. Thus, the impedance seen from the entrance inward is measured on 25 subjects. Most subjects participated in the previous measurement of the ratio between the pressures at the open...

  15. From Ear to Brain

    Science.gov (United States)

    Kimura, Doreen

    2011-01-01

    In this paper Doreen Kimura gives a personal history of the "right-ear effect" in dichotic listening. The focus is on the early ground-breaking papers, describing how she did the first dichotic listening studies relating the effects to brain asymmetry. The paper also gives a description of the visual half-field technique for lateralized stimulus…

  16. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  17. Seeing With the Ears

    NARCIS (Netherlands)

    Koenderink, Jan

    2015-01-01

    In recent talks, I mentioned how my artist friends often complain that their clients see with their ears. It recently dawned on me that nobody understood what I said, or—worse—got the wrong idea. The audience thinks of bionic devices (Proulx, Stoerig, Ludowig, & Knoll, 2008) or bat echo location

  18. Ear infection - acute

    Science.gov (United States)

    ... to the back of the throat. Normally, this tube drains fluid that is made in the middle ear. ... allows air to get in so fluids can drain more easily. Usually the tubes fall out by themselves. Those that don't ...

  19. Low-set ears and pinna abnormalities

    Science.gov (United States)

    Low-set ears; Microtia; "Lop" ear; Pinna abnormalities; Genetic defect - pinna; Congenital defect - pinna ... conditions: Abnormal folds or location of the pinna Low-set ears No opening to the ear canal ...

  20. Low Pressure Circuit Control and adjust System Test

    International Nuclear Information System (INIS)

    Rubio, R.O; Brendstrup, C.J; Ocampo, A.C

    2000-01-01

    The hydraulic mechanism (MSAC) is a system that will be employed in the movement of the control rods of the CAREM-25 reactor.In this report, the experimental work on a prototype of MSAC in a low pressure circuit is presented: also the methodology and conclusions.Basic thermalhydraulic data from the MSAC was obtained, and the most relevant control parameters were determined.The response of the mechanism to changes in the control parameters was also evaluated. In conclusion, the response of the MSAC fulfills the aspects of reliability and repetitive movement with water flow pulses control, in the low pressure circuit at the Laboratorio de Mecanica, Materiales y Mediciones of INVAP S.E

  1. Dual-fuel engine with cylinder pressure based control

    Energy Technology Data Exchange (ETDEWEB)

    Ritscher, Bert [Caterpillar Motoren GmbH und Co. KG, Kiel (Germany). Large Power Systems Div.

    2013-10-15

    Cylinder pressure sensors were initially used to detect knocking and misfiring on spark ignited gas engines. On its latest MaK brand dual-fuel engine, Caterpillar Motoren is harnessing the deep insights into combustion and engine condition that can be derived direct from the origin of engine power in sophisticated control, monitoring and diagnostic systems. (orig.)

  2. Controlling a negative loaded hydraulic cylinder using pressure feedback

    DEFF Research Database (Denmark)

    Hansen, M.R.; Andersen, T.O.

    2010-01-01

    This paper is concerned with the inherent oscillatory nature of pressure compensated velocity control of a hydraulic cylinder subjected to a negative load and suspended by means of an over-center valve. Initially, a linearized stability analysis of such a hydraulic circuit is carried out clearly ...... in a nonlinear time domain simulation model validating the linear stability analysis....

  3. 49 CFR 192.197 - Control of the pressure of gas delivered from high-pressure distribution systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Control of the pressure of gas delivered from high-pressure distribution systems. 192.197 Section 192.197 Transportation Other Regulations Relating to... STANDARDS Design of Pipeline Components § 192.197 Control of the pressure of gas delivered from high...

  4. Automatic power control for a pressurized water reactor

    International Nuclear Information System (INIS)

    Hah, Yung Joon

    1994-02-01

    During a normal operation of a pressurized water reactor (PWR), the reactivity is controlled by control rods, boron, and the average temperature of the primary coolant. Especially in load follow operation, the reactivity change is induced by changes in power level and effects of xenon concentration. The control of the core power distribution is concerned, mainly, with the axial power distribution which depends on insertion and withdrawal of the control rods resulting in additional reactivity compensation. The utilization of part strength control element assemblies (PSCEAs) is quite appropriate for a control of the power distribution in the case of Yonggwang Nuclear Unit 3 (YGN Unit 3). However, control of the PSCEAs is not automatic, and changes in the boron concentration by dilution/boration are done manually. Thus, manual control of the PSCEAs and the boron concentration require the operator's experience and knowledge for a successful load follow operation. In this thesis, the new concepts have been proposed to adapt for an automatic power control in a PWR. One of the new concepts is the mode K control, another is a fuzzy power control. The system in mode K control implements a heavy-worth bank dedicated to axial shape control, independent of the existing regulating banks. The heavy bank provides a monotonic relationship between its motion and the axial power shape change, which allows automatic control of the axial power distribution. And the mode K enables precise regulation, by using double closed-loop control of the reactor coolant temperature and the axial power difference. Automatic reactor power control permits the nuclear power plant to accommodate the load follow operations, including frequency control, to respond to the grid requirements. The mode K reactor control concepts were tested using simulation responses of a Korean standardized 1000-MWe PWR which is a reference plant for the YGN Unit 3. The simulation results illustrate that the mode K would be

  5. Pressure control valve using proportional electro-magnetic solenoid actuator

    International Nuclear Information System (INIS)

    Yun, So Nam; Ham, Young Bog; Park, Pyoung Won

    2006-01-01

    This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed

  6. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation

    International Nuclear Information System (INIS)

    Schranz, C; Möller, K; Becher, T; Schädler, D; Weiler, N

    2014-01-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (p I ), inspiration and expiration time (t I , t E ) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal p I and adequate t E can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's ‘optimized’ settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end

  7. Model-based setting of inspiratory pressure and respiratory rate in pressure-controlled ventilation.

    Science.gov (United States)

    Schranz, C; Becher, T; Schädler, D; Weiler, N; Möller, K

    2014-03-01

    Mechanical ventilation carries the risk of ventilator-induced-lung-injury (VILI). To minimize the risk of VILI, ventilator settings should be adapted to the individual patient properties. Mathematical models of respiratory mechanics are able to capture the individual physiological condition and can be used to derive personalized ventilator settings. This paper presents model-based calculations of inspiration pressure (pI), inspiration and expiration time (tI, tE) in pressure-controlled ventilation (PCV) and a retrospective evaluation of its results in a group of mechanically ventilated patients. Incorporating the identified first order model of respiratory mechanics in the basic equation of alveolar ventilation yielded a nonlinear relation between ventilation parameters during PCV. Given this patient-specific relation, optimized settings in terms of minimal pI and adequate tE can be obtained. We then retrospectively analyzed data from 16 ICU patients with mixed pathologies, whose ventilation had been previously optimized by ICU physicians with the goal of minimization of inspiration pressure, and compared the algorithm's 'optimized' settings to the settings that had been chosen by the physicians. The presented algorithm visualizes the patient-specific relations between inspiration pressure and inspiration time. The algorithm's calculated results highly correlate to the physician's ventilation settings with r = 0.975 for the inspiration pressure, and r = 0.902 for the inspiration time. The nonlinear patient-specific relations of ventilation parameters become transparent and support the determination of individualized ventilator settings according to therapeutic goals. Thus, the algorithm is feasible for a variety of ventilated ICU patients and has the potential of improving lung-protective ventilation by minimizing inspiratory pressures and by helping to avoid the build-up of clinically significant intrinsic positive end-expiratory pressure.

  8. Device for regulating and controlling of fluid pressure

    International Nuclear Information System (INIS)

    Andrews, H.N.; Singleton, N.R.; Frisch, E.; Stein, P.C.

    1972-01-01

    A pressure regulating valve for high pressures, suitable for PWR pressurisers, is based on controlled leakage. The valve may also function as a safety valve. The valve and seat surfaces are machined such that an annular space is formed towards the inner edge, and into this space cold fluid may be injected, thus preventing crud deposition and hindering steam formation. Fluid also leaks into the annular space between two bellows, which exert a closing force on the valve, in addition to the closing force provided by springs, whose force is adjustable by means of a screw arrangement. (JIW)

  9. Fuzzy power control algorithm for a pressurized water reactor

    International Nuclear Information System (INIS)

    Hah, Y.J.; Lee, B.W.

    1994-01-01

    A fuzzy power control algorithm is presented for automatic reactor power control in a pressurized water reactor (PWR). Automatic power shape control is complicated by the use of control rods with a conventional proportional-integral-differential controller because it is highly coupled with reactivity compensation. Thus, manual shape controls are usually employed even for the limited capability needed for load-following operations including frequency control. In an attempt to achieve automatic power shape control without any design modifications to the core, a fuzzy power control algorithm is proposed. For the fuzzy control, the rule base is formulated based on a multiple-input multiple-output system. The minimum operation rule and the center of area method are implemented for the development of the fuzzy algorithm. The fuzzy power control algorithm has been applied to Yonggwang Nuclear Unit 3. The simulation results show that the fuzzy control can be adapted as a practical control strategy for automatic reactor power control of PWRs during the load-following operations

  10. TRACKING CONTROL FOR A HYDRAULIC DRIVE WITH A PRESSURE COMPENSATOR

    Directory of Open Access Journals (Sweden)

    S. V. Aranovskiy

    2015-07-01

    Full Text Available A problem of tracking control is considered for a hydraulic drive with a pressure compensator that is widespread in the equipment of heavy-duty machines. Method. The control problem is solved by means of a switching sliding-mode controller coupled with static nonlinear compensation and desired velocity feedforward. Main Results. Mathematical model of a hydraulic drive is given in view of the pressure compensator presence. Traditional model of a hydraulic drive is formulated for a system with a spool valve; purpose and principles of operation of the pressure compensator in hydraulic systems are described, and the extended model is presented illustrating compensator contribution to overall system dynamics. It is shown that the obtained model has an input static nonlinearity; the nonlinearity cancellation method is proposed giving the possibility for injection of a desired velocity feedforward term. The control law is chosen as a switching one and two chattering attenuation methods are studied: equivalent control estimation via filtering and sign function integration. Experimental studies are performed at a forestry hydraulic crane prototype and illustrate high tracking accuracy achieved for typical crane motions. Practical Significance. The results are suitable for heavy-duty hydraulic machines automation in construction, road building and forestry.

  11. Ear Acupuncture versus  local anaestethic for pain relief during perineal repair - a randomised controlled trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    ACUPUNCTURE OR LOCAL ANAESTETICS FOR PAIN RELIEF DURING PERINEAL REPAIR AFTER VAGINAL DELIVERY: A RANDOMISED CONTROLLED TRIAL.   By:  Sara Kindberg. Midwife and PhD student, Sønderborg Hospital, Denmark. Objective: To evaluate acupuncture as a new method of pain relief for postpartum perineal...... as photos of the acupuncture points. Perspectives:  Basic midwifery services such as providing sufficient pain relief during perineal repair still need improvement. Clinical practice should be improved continuously and thus produce reliable evidence on different pain relief methods. Website:        http...

  12. Controlling Vapor Pressure In Hanging-Drop Crystallization

    Science.gov (United States)

    Carter, Daniel C.; Smith, Robbie

    1988-01-01

    Rate of evaporation adjusted to produce larger crystals. Device helps to control vapor pressure of water and other solvents in vicinity of hanging drop of solution containing dissolved enzyme protein. Well of porous frit (sintered glass) holds solution in proximity to drop of solution containing protein or enzyme. Vapor from solution in frit controls evaporation of solvent from drop to control precipitation of protein or enzyme. With device, rate of nucleation limited to decrease number and increase size (and perhaps quality) of crystals - large crystals of higher quality needed for x-ray diffraction studies of macromolecules.

  13. Circadian blood pressure patterns and blood pressure control in patients with chronic kidney disease.

    Science.gov (United States)

    Di Daniele, Nicola; Fegatelli, Danilo Alunni; Rovella, Valentina; Castagnola, Veronica; Gabriele, Marco; Scuteri, Angelo

    2017-12-01

    Hypertension is a major risk factor for chronic kidney disease (CKD), and CKD progression is associated with suboptimal blood pressure (BP) control. Here we evaluate the impact of CKD on the attainment of BP control and the circadian BP profile in older subjects. In this observational study, we studied 547 patients referred to the hypertension clinic, of whom 224 (40.9%) had CKD. Blood pressure (BP) control and circadian BP patterns were evaluated by 24-hour ambulatory BP monitoring. Circadian BP variability was measured as the within-subject SD of BP, the percentage of measurements exceeding normal values, hypotension, and dipping status. The attainment of adequate BP control was similar in subjects with or without CKD (around 31%). Logistic regression analysis indicated that CKD was not a determinant of adequate BP control (OR 1.004; 95% CI 0.989-1.019; p = 0.58). Patients with CKD presented as twice as higher prevalence of reverse dipper (night-time peak) for systolic BP and episodes of hypotension during daytime, independently of BP control. Knowledge of the circadian pattern of BP in hypertensive subjects with CKD could inform better than attainment of BP target about risky condition for CKD progression and cognitive decline and allow a more personalized antihypertensive treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. A Computer Controlled Precision High Pressure Measuring System

    Science.gov (United States)

    Sadana, S.; Yadav, S.; Jha, N.; Gupta, V. K.; Agarwal, R.; Bandyopadhyay, A. K.; Saxena, T. K.

    2011-01-01

    A microcontroller (AT89C51) based electronics has been designed and developed for high precision calibrator based on Digiquartz pressure transducer (DQPT) for the measurement of high hydrostatic pressure up to 275 MPa. The input signal from DQPT is converted into a square wave form and multiplied through frequency multiplier circuit over 10 times to input frequency. This input frequency is multiplied by a factor of ten using phased lock loop. Octal buffer is used to store the calculated frequency, which in turn is fed to microcontroller AT89C51 interfaced with a liquid crystal display for the display of frequency as well as corresponding pressure in user friendly units. The electronics developed is interfaced with a computer using RS232 for automatic data acquisition, computation and storage. The data is acquired by programming in Visual Basic 6.0. This system is interfaced with the PC to make it a computer controlled system. The system is capable of measuring the frequency up to 4 MHz with a resolution of 0.01 Hz and the pressure up to 275 MPa with a resolution of 0.001 MPa within measurement uncertainty of 0.025%. The details on the hardware of the pressure measuring system, associated electronics, software and calibration are discussed in this paper.

  15. The high pressure electronic control system in liquid chromatography

    International Nuclear Information System (INIS)

    Popescu, Stefan; Popeneciu, Gabriel; Toadere, Florin

    2002-01-01

    The Liquid Chromatography system can perform a wide variety of measurements and separations especially for the organic liquids, with maximum applications flexibility for less than half price of Gas Chromatography. The repeatability and accuracy of results in quantitative high pressure liquid chromatography are highly dependent on the reproducibility and accuracy of both integrated flow rate and mobile phase composition. Flow rate fluctuation leads to poor reproducibility in both integrated peak areas and retention times. Similarly, poor control of mobile phase composition will cause poor repeatability of retention time and peak heights. The our Solvent Delivery System SDS 200 is a single pump system which provides precise compensated flow rates from 0.01 to 10 mL/min, selectable upper pressure limits of 0 to 100 bar or 10 to 450 bar, and solvent compressibility correction. Ternary solvent system on-line mixing capability saves time, reduces solvent waste and provides more flexibility for difficult separations. The pump itself has two different displacement pistons which are used alternately on both suction and discharge, so that intake of the solvent are synchronous. The evacuated solvent from the two pump's chambers is mixed in the reference unit and then is supplied to the damping unit for flow ripple reduction. The SDS Electronic Module ensures the functions: controls the programmed flow rate, detects and shows the solvent pressure in solvent, supplies the step motor, measures and limits the solvent pressure. The control panel of SDS 200, contains a two-stages flow decimal programmer, a eight-positions knob for upper pressure limits, an alarm LED and a parallel port for connection to a PC system. (authors)

  16. Effects of middle ear quasi-static stiffness on sound transmission quantified by a novel 3-axis optical force sensor.

    Science.gov (United States)

    Dobrev, Ivo; Sim, Jae Hoon; Aqtashi, Baktash; Huber, Alexander M; Linder, Thomas; Röösli, Christof

    2018-01-01

    Intra-operative quantification of the ossicle mobility could provide valuable feedback for the current status of the patient's conductive hearing. However, current methods for evaluation of middle ear mobility are mostly limited to the surgeon's subjective impression through manual palpation of the ossicles. This study investigates how middle ear transfer function is affected by stapes quasi-static stiffness of the ossicular chain. The stiffness of the middle ear is induced by a) using a novel fiber-optic 3-axis force sensor to quantify the quasi-static stiffness of the middle ear, and b) by artificial reduction of stapes mobility due to drying of the middle ear. Middle ear transfer function, defined as the ratio of the stapes footplate velocity versus the ear canal sound pressure, was measured with a single point LDV in two conditions. First, a controlled palpation force was applied at the stapes head in two in-plane (superior-inferior or posterior-anterior) directions, and at the incus lenticular process near the incudostapedial joint in the piston (lateral-medial) direction with a novel 3-axis PalpEar force sensor (Sensoptic, Losone, Switzerland), while the corresponding quasi-static displacement of the contact point was measured via a 3-axis micrometer stage. The palpation force was applied sequentially, step-wise in the range of 0.1-20 gF (1-200 mN). Second, measurements were repeated with various stages of stapes fixation, simulated by pre-load on the stapes head or drying of the temporal bone, and with severe ossicle immobilization, simulated by gluing of the stapes footplate. Simulated stapes fixation (forced drying of 5-15 min) severely decreases (20-30 dB) the low frequency (4 kHz) response. Stapes immobilization (gluing of the footplate) severely reduces (20-40 dB) the low and mid frequency response (force (Force-displacement measurements around the incudostapedial joint showed quasi-static stiffness in the range of 200-500 N/m for normal middle

  17. [Improved methods for researching isolated carotid sinus baroreceptors automatically controlling for sinus pressure].

    Science.gov (United States)

    Wei, Hua; Zhao, Hai-Yan; Liu, Ping; Huang, Hai-Xia; Wang, Wei; Fu, Xiao-Suo; Niu, Wei-Zhen

    2013-01-01

    To develop a system for automatically controlling carotid sinus pressure in the study on baroreceptors. The preparation containing carotid sinus with parts of the connected vessels and carotid sinus nerve (CS-CSN) were isolated and perfused. A critical pressure controlling component (PRE-U, Hoerbiger, Deutschland) dictated by a computer was integrated into the system to clamp the intrasinus pressure. The pressure command and the relevant intrasinus pressure were compared to evaluate the validity of the pressure controlling system. A variety of sinus pressure-controlling patterns, including pulsation, ramp and step pressures, could be achieved accurately by using the system, and the pressure-dependent discharge activities of sinus nerve were confirmed. This system for clamping carotid sinus pressure could realize multiple pressure-controlling patterns and is a useful and flexible pressure controlling method that could applied in the study on mechano-electric transduction of baroreceptors.

  18. Optimized damper control of pressure and airflow in ventilation systems

    DEFF Research Database (Denmark)

    Koulani, Chrysanthi Sofia; Hviid, Christian Anker; Terkildsen, Søren

    2014-01-01

    Conventional control strategies in variable air volume (VAV) ventilation systems do not take fully into advantage the potential energy savings since the system operation is based on maintaining a constant static pressure (CSP) set point in the main duct irrespective of the actual pressure demand...... by using the Simulink programming tool which is addon software to MATLAB mathematical programming language. A model of a VAV ventilation system was created in Simulink based on the International Building Physics Toolbox (IBPT); the IBPT thermal zone was remodelled in order to calculate dynamically...... the airflow demand according to the zone air temperature. The performance of the Simulink model was evaluated based on the experimental setup of the ventilation system. The SPR control method established stable system operation and was proven efficient to maintain comfortable space conditions while reducing...

  19. Development of Steam Pressure Control Logic for SMART

    International Nuclear Information System (INIS)

    Sneed, Todd; Godbole, Sadashiva; Streaath, Drew

    2011-01-01

    The objective of this work is to develop the Steam Pressure Control Logic(SPCL) in order to satisfy the performance requirements of SMART plant control systems. The final conceptual SPCL described in this report has been developed after studying the SMART system together with the secondary system, patents of control systems for fossil and unclear power plants featuring OTSG's, and familiarity and experience with power plant control systems. The logic represents a combination of good features from various control concepts to make SPCL effective in controlling relevant SMART secondary system parameter. The SPCL includes some new features, such as use of FCV position setpoint to control pump speed, relaxation of the measure RC hot-leg temperature to accelerate load-following response, and use of steam flow as feedwater flow setpoint. This report describes performance evaluation results for the SMART SPCL MMS model. The evaluation is based on three transients under three control modes. Three transients include load-following ramp at normal ramp rate to reduce load and then to increase load, turbin trip, and loss of external electrical load resulting in only house load as the remaining load. The three control modes include coordinated, turbin-following, and feedwater-following. It seems that any of the three control modes is viable for SMART control

  20. [Control of blood pressure in hypertensive patients on combination therapy].

    Science.gov (United States)

    de la Sierra, Alejandro; Oliveras, Anna; Armario, Pedro; Lucas, Silvia

    2015-02-20

    The impact of antihypertensive treatment on blood pressure (BP) control is fairly unknown. The aim of the study was to evaluate the degree of BP control and its relationship with treatment-related factors in hypertensive patients treated with 2 or 3 agents and attended in referral units. We studied 1,337 hypertensive subjects (41% women) with a mean age (SD) of 63 (12) years, who were receiving 2 or 3 antihypertensive drugs. The degree of BP control was estimated in a single visit by the proportion of patients with BP below 140/90mmHg. BP was controlled in 767 patients (57%). Lack of BP control was related to older age (12% risk for each 10-year increase) and the presence of microalbuminuria (64% risk increase). In those treated with 2 agents, BP control was 61%, without differences between those treated with fixed-drug or free combinations. BP control in those treated with 3 agents was 55%, higher in those receiving 3 agents in a fixed-drug combination (68%) compared with those on 3 agents administered separately (52%; P=.025). Drug classes used in combinations did not influence the degree of BP control. The degree of BP control in patients treated with 2 or 3 agents is 57%. Microalbuminuria is related to a lack of BP control. In those receiving 3 agents, the use of fixed-drug combinations is associated with better BP control. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  1. Blood pressure control to prevent decline in cognition after stroke

    Directory of Open Access Journals (Sweden)

    Ihle-Hansen H

    2015-06-01

    between achieved goal blood pressure or blood pressure reduction after 1 year and the diagnoses of MCI or dementia (P=0.32–0.56.Conclusion: Treatment of hypertension is important for primary and secondary prevention of stroke. Showing a potential beneficial effect of blood pressure control on cognitive function, however, probably needs longer follow-up. Keywords: cognitive impairment, hypertension, cerebrovascular disease, risk factor management, secondary prevention

  2. a Middle-Ear Reverse Transfer Function Computed from Vibration Measurements of Otoacoustic Emissions on the Ear Drum of the Guinea PIG

    Science.gov (United States)

    Dalhoff, Ernst; Turcanu, Diana; Gummer, Anthony W.

    2009-02-01

    Using distortion products measured as vibration of the umbo and as sound pressure in the ear canal of guinea pigs, we calculated the corresponding reverse transfer function. We compare the measurements with a middle-ear model taken from the literature and adapted to the guinea pig. A reasonable fit could be achieved. We conclude that the reverse transfer function will be useful to aid fitting a middle-ear model to measured transfer functions of human subjects.

  3. Research and design of 3He pressure control loop

    International Nuclear Information System (INIS)

    Huang Xin; Zhang Peisheng; Tang Guoliang; Zhang Aimin; Zhang Yingchao

    2008-01-01

    In order to carry out power transient tests for PWR fuel element in China Advanced Research Reactor (CARR), the research and conceptual design of 3He pressure control loop were completed. The working principle, design parameters and technological flow of the loop were described. It is seen that the a He loop can adjust the power of the tested PWR fuel element rapidly, evenly and flexibly and it is an optimal path to realize the power transient regulation for tested PWR fuel. (authors)

  4. Control of blood pressure in Scotland: the rule of halves.

    Science.gov (United States)

    Smith, W C; Lee, A J; Crombie, I K; Tunstall-Pedoe, H

    1990-04-14

    Audit of detection, treatment, and control of hypertension in adults in Scotland. Cross sectional survey with random population sampling. General practice centres in 22 Scottish districts. 5123 Men and 5236 women aged 40-59 in the Scottish heart health study, randomly selected from 22 districts throughout Scotland, of whom 1262 men and 1061 women had hypertension (defined as receiving antihypertensive treatment or with blood pressure above defined cut off points). Hypertension (assessed by standardised recording, questionnaire on diagnosis, and antihypertensive drug treatment) according to criteria of the World Health Organisation (receiving antihypertensive treatment or blood pressure greater than or equal to 160/95 mm Hg, or both) and to modified criteria of the British Hypertension Society. In half the men with blood pressure greater than or equal to 160/95 mm Hg hypertension was undetected (670/1262, 53%), in half of those in whom it had been detected it was untreated (250/592, 42%), and in half of those receiving treatment it was not controlled (172/342, 50%). In women the numbers were: 486/1061, 46%; 188/575, 33%; and 155/387, 40% respectively. Assessment of blood pressure according to the British Hypertension Society's recommendations showed an improvement, but in only a quarter of men and 42% of women was hypertension detected and treated satisfactorily (142/561, 215/514 respectively). The detection and control of hypertension in Scotland is unsatisfactory, affecting management of this and other conditions, such as high blood cholesterol concentration, whose measurement is opportunistic and selective and depends on recognition of other risk factors.

  5. Reduction of emission level in approach signals of greater mouse-eared bats (Myotis myotis): No evidence for a closed loop control system for intensity compensation.

    Science.gov (United States)

    Budenz, Tobias; Denzinger, Annette; Schnitzler, Hans-Ulrich

    2018-01-01

    Bats lower the emission SPL when approaching a target. The SPL reduction has been explained by intensity compensation which implies that bats adjust the emission SPL to perceive the retuning echoes at the same level. For a better understanding of this control mechanism we recorded the echolocation signals of four Myotis myotis with an onboard microphone when foraging in the passive mode for rustling mealworms offered in two feeding dishes with different target strength, and determined the reduction rate for the emission SPL and the increase rate for the SPL of the returning echoes. When approaching the dish with higher target strength bats started the reduction of the emission SPL at a larger reaction distance (1.05 ± 0.21 m) and approached it with a lower reduction rate of 7.2 dB/halving of distance (hd), thus producing a change of echo rate at the ears of + 4 dB/hd. At the weaker target reaction distance was shorter (0.71 ± 0.24 m) and the reduction rate (9.1 dB/hd) was higher, producing a change of echo rate of-1.2 dB/hd. Independent of dish type, bats lowered the emission SPL by about 26 dB on average. In one bat where the echo SPL from both targets could be measured, the reduction of emission SPL was triggered when the echo SPL surpassed a similar threshold value around 41-42 dB. Echo SPL was not adjusted at a constant value indicating that Myotis myotis and most likely all other bats do not use a closed loop system for intensity compensation when approaching a target of interest. We propose that bats lower the emission SPL to adjust the SPL of the perceived pulse-echo-pairs to the optimal auditory range for the processing of range information and hypothesize that bats use flow field information not only to control the reduction of the approach speed to the target but also to control the reduction of emission SPL.

  6. The effect of different sowing depths on fresh ear yield and some ear characteristics of sweet corn

    Directory of Open Access Journals (Sweden)

    Bekir Atar

    2017-12-01

    Full Text Available The research was conducted with aim to investigate effect on fresh ear yield and some ear characteristics of sweet corn of sowing at different depths during 2015 and 2016 years in Isparta. The experiments were set up according to randomized complete block design with three replicates using BATEM TATLI sweet corn cultivar. Furrows were opened at depths of 10 and 20 cm after the soil preparation, and seeds were sown in the 4-5 cm depth in to these furrows. According to means of years, while furrow sowing increased ear diameter, ear weigh, number of kernels per ear and fresh ear yield compared to control, it was not effect on ear length. In the research, between 10 cm and 20 cm furrow sowing wasn’t significant statistically. Fresh ear yield in control, 10 cm and 20 cm furrow sowing were measured as 1110.9 kg ha-1 , 1228.4 kg ha-1 and 1289.4 kg ha-1 , respectively. According to results of research, 5 cm deep sowing in 10 cm furrows should be advised in sweet corn cultivation.

  7. Comparison of Microbiological Flora in the External Auditory Canal of Normal Ear and an Ear with Acute Otitis Externa.

    Science.gov (United States)

    Ghanpur, Asheesh Dora; Nayak, Dipak Ranjan; Chawla, Kiran; Shashidhar, V; Singh, Rohit

    2017-09-01

    Acute Otitis Externa (AOE) is also known as swimmer's ear. Investigations initiated during World War II firmly established the role of bacteria in the aetiology of Acute Otitis Externa. To culture the microbiological flora of the normal ear and compare it with the flora causing AOE and to know the role of normal ear canal flora and anaerobes in the aetiology. A prospective observational study was conducted on 64 patients clinically diagnosed with unilateral AOE. Ear swabs were taken from both the ears. Microbiological flora was studied considering diseased ear as test ear and the normal ear as the control. Aerobic and anaerobic cultures were done. Severity of the disease was assessed by subjective and objective scores. Effect of topical treatment with ichthammol glycerine pack was assessed after 48 hours and scores were calculated again. Patients with scores < 4 after pack removal were started on systemic antibiotics and were assessed after seven days of antibiotics course. Data was analysed using Paired t-test, Wilcoxon signed ranks test and Chi-square test. A p-value < 0.05 was considered significant. Pseudomonas aeruginosa (33%) was the most common bacteria cultured from the ear followed by Methicillin Resistant Staphylococcus aureus (MRSA) (18%). Patients with anaerobic organism in the test ear had severe symptoms and needed systemic antibiotic therapy. Most of the cases may respond to empirical antibiotic therapy. In cases with severe symptoms and the ones refractory to empirical treatment, a culture from the ear canal will not be a tax on the patient. This helps in giving a better understanding about the disease, causative organisms and helps in avoiding the use of inappropriate antibiotics that usually result in developing resistant strains of bacteria.

  8. Radiation-pressure-mediated control of an optomechanical cavity

    Science.gov (United States)

    Cripe, Jonathan; Aggarwal, Nancy; Singh, Robinjeet; Lanza, Robert; Libson, Adam; Yap, Min Jet; Cole, Garrett D.; McClelland, David E.; Mavalvala, Nergis; Corbitt, Thomas

    2018-01-01

    We describe and demonstrate a method to control a detuned movable-mirror Fabry-Pérot cavity using radiation pressure in the presence of a strong optical spring. At frequencies below the optical spring resonance, self-locking of the cavity is achieved intrinsically by the optomechanical (OM) interaction between the cavity field and the movable end mirror. The OM interaction results in a high rigidity and reduced susceptibility of the mirror to external forces. However, due to a finite delay time in the cavity, this enhanced rigidity is accompanied by an antidamping force, which destabilizes the cavity. The cavity is stabilized by applying external feedback in a frequency band around the optical spring resonance. The error signal is sensed in the amplitude quadrature of the transmitted beam with a photodetector. An amplitude modulator in the input path to the cavity modulates the light intensity to provide the stabilizing radiation pressure force.

  9. Modeling Analysis of Biomechanical Changes of Middle Ear and Cochlea in Otitis Media

    Science.gov (United States)

    Gan, Rong Z.; Zhang, Xiangming; Guan, Xiying

    2011-11-01

    A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea.

  10. Influence of Baseline Diastolic Blood Pressure on Effects of Intensive Compared With Standard Blood Pressure Control.

    Science.gov (United States)

    Beddhu, Srinivasan; Chertow, Glenn M; Cheung, Alfred K; Cushman, William C; Rahman, Mahboob; Greene, Tom; Wei, Guo; Campbell, Ruth C; Conroy, Margaret; Freedman, Barry I; Haley, William; Horwitz, Edward; Kitzman, Dalane; Lash, James; Papademetriou, Vasilios; Pisoni, Roberto; Riessen, Erik; Rosendorff, Clive; Watnick, Suzanne G; Whittle, Jeffrey; Whelton, Paul K

    2018-01-09

    In individuals with a low diastolic blood pressure (DBP), the potential benefits or risks of intensive systolic blood pressure (SBP) lowering are unclear. SPRINT (Systolic Blood Pressure Intervention Trial) was a randomized controlled trial that compared the effects of intensive (target baseline DBP. Mean baseline SBP and DBP were 139.7±15.6 and 78.1±11.9 mm Hg, respectively. Regardless of the randomized treatment, baseline DBP had a U-shaped association with the hazard of the primary cardiovascular disease outcome. However, the effects of the intensive SBP intervention on the primary outcome were not influenced by baseline DBP level ( P for interaction=0.83). The primary outcome hazard ratio for intensive versus standard treatment was 0.78 (95% confidence interval, 0.57-1.07) in the lowest DBP quintile (mean baseline DBP, 61±5 mm Hg) and 0.74 (95% confidence interval, 0.61-0.90) in the upper 4 DBP quintiles (mean baseline DBP, 82±9 mm Hg), with an interaction P value of 0.78. Results were similar for all-cause death and kidney events. Low baseline DBP was associated with increased risk of cardiovascular disease events, but there was no evidence that the benefit of the intensive SBP lowering differed by baseline DBP. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01206062. © 2017 American Heart Association, Inc.

  11. Instrumentation and control strategies for an integral pressurized water reactor

    Directory of Open Access Journals (Sweden)

    Belle R. Upadhyaya

    2015-03-01

    Full Text Available Several vendors have recently been actively pursuing the development of integral pressurized water reactors (iPWRs that range in power levels from small to large reactors. Integral reactors have the features of minimum vessel penetrations, passive heat removal after reactor shutdown, and modular construction that allow fast plant integration and a secure fuel cycle. The features of an integral reactor limit the options for placing control and safety system instruments. The development of instrumentation and control (I&C strategies for a large 1,000 MWe iPWR is described. Reactor system modeling—which includes reactor core dynamics, primary heat exchanger, and the steam flashing drum—is an important part of I&C development and validation, and thereby consolidates the overall implementation for a large iPWR. The results of simulation models, control development, and instrumentation features illustrate the systematic approach that is applicable to integral light water reactors.

  12. Physiological artifacts in scalp EEG and ear-EEG.

    Science.gov (United States)

    Kappel, Simon L; Looney, David; Mandic, Danilo P; Kidmose, Preben

    2017-08-11

    A problem inherent to recording EEG is the interference arising from noise and artifacts. While in a laboratory environment, artifacts and interference can, to a large extent, be avoided or controlled, in real-life scenarios this is a challenge. Ear-EEG is a concept where EEG is acquired from electrodes in the ear. We present a characterization of physiological artifacts generated in a controlled environment for nine subjects. The influence of the artifacts was quantified in terms of the signal-to-noise ratio (SNR) deterioration of the auditory steady-state response. Alpha band modulation was also studied in an open/closed eyes paradigm. Artifacts related to jaw muscle contractions were present all over the scalp and in the ear, with the highest SNR deteriorations in the gamma band. The SNR deterioration for jaw artifacts were in general higher in the ear compared to the scalp. Whereas eye-blinking did not influence the SNR in the ear, it was significant for all groups of scalps electrodes in the delta and theta bands. Eye movements resulted in statistical significant SNR deterioration in both frontal, temporal and ear electrodes. Recordings of alpha band modulation showed increased power and coherence of the EEG for ear and scalp electrodes in the closed-eyes periods. Ear-EEG is a method developed for unobtrusive and discreet recording over long periods of time and in real-life environments. This study investigated the influence of the most important types of physiological artifacts, and demonstrated that spontaneous activity, in terms of alpha band oscillations, could be recorded from the ear-EEG platform. In its present form ear-EEG was more prone to jaw related artifacts and less prone to eye-blinking artifacts compared to state-of-the-art scalp based systems.

  13. Fuzzy Coordinated PI Controller: Application to the Real-Time Pressure Control Process

    Directory of Open Access Journals (Sweden)

    N. Kanagaraj

    2008-01-01

    Full Text Available This paper presents the real-time implementation of a fuzzy coordinated classical PI control scheme for controlling the pressure in a pilot pressure tank system. The fuzzy system has been designed to track the variation parameters in a feedback loop and tune the classical controller to achieve a better control action for load disturbances and set point changes. The error and process inputs are chosen as the inputs of fuzzy system to tune the conventional PI controller according to the process condition. This online conventional controller tuning technique will reduce the human involvement in controller tuning and increase the operating range of the conventional controller. The proposed control algorithm is experimentally implemented for the real-time pressure control of a pilot air tank system and validated using a high-speed 32-bit ARM7 embedded microcontroller board (ATMEL AT91M55800A. To demonstrate the performance of the fuzzy coordinated PI control scheme, results are compared with a classical PI and PI-type fuzzy control method. It is observed that the proposed controller structure is able to quickly track the parameter variation and perform better in load disturbances and also for set point changes.

  14. Optimization and Control of Pressure Swing Adsorption Processes Under Uncertainty

    KAUST Repository

    Khajuria, Harish

    2012-03-21

    The real-time periodic performance of a pressure swing adsorption (PSA) system strongly depends on the choice of key decision variables and operational considerations such as processing steps and column pressure temporal profiles, making its design and operation a challenging task. This work presents a detailed optimization-based approach for simultaneously incorporating PSA design, operational, and control aspects under the effect of time variant and invariant disturbances. It is applied to a two-bed, six-step PSA system represented by a rigorous mathematical model, where the key optimization objective is to maximize the expected H2 recovery while achieving a closed loop product H2 purity of 99.99%, for separating 70% H2, 30% CH4 feed. The benefits over sequential design and control approach are shown in terms of closed-loop recovery improvement of more than 3%, while the incorporation of explicit/multiparametric model predictive controllers improves the closed loop performance. © 2012 American Institute of Chemical Engineers (AIChE).

  15. Control of Fusarium verticillioides, cause of ear rot of maize, by Pseudomonas fluorescens

    DEFF Research Database (Denmark)

    Nayaka, Siddaiah Chandra; Shankar, Akarere C. Udaya; Reddy, Munagala S.

    2009-01-01

    Abstract BACKGROUND: Maize is one of the staple food crops grown in India. Fusarium verticillioides (Sacc.) Nirenberg is the most important fungal pathogen of maize, associated with diseases such as ear rot and kernel rot. Apart from the disease, it is capable of producing fumonisins, which have...... disease and fumonisin accumulation, and also to study the capacity to promote growth and yield of maize. In vitro assays were conducted to test the efficacy of P. fluorescens as a seed treatment on seed germination, seedling vigour and also the incidence of F. verticillioides in different maize cultivars....... verticillioides and the level of fumonisins to a maximum extent compared with the other treatments. CONCLUSION: The study demonstrates the potential role of P. fluorescens and its formulations in ear rot disease management. The biocontrol potential of this isolate is more suited for fumonisin reduction in maize...

  16. Using Solar Radiation Pressure to Control L2 Orbits

    Science.gov (United States)

    Tene, Noam; Richon, Karen; Folta, David

    1998-01-01

    The main perturbations at the Sun-Earth Lagrange points L1 and L2 are from solar radiation pressure (SRP), the Moon and the planets. Traditional approaches to trajectory design for Lagrange-point orbits use maneuvers every few months to correct for these perturbations. The gravitational effects of the Moon and the planets are small and periodic. However, they cannot be neglected because small perturbations in the direction of the unstable eigenvector are enough to cause exponential growth within a few months. The main effect of a constant SRP is to shift the center of the orbit by a small distance. For spacecraft with large sun-shields like the Microwave Anisotropy Probe (MAP) and the Next Generation Space Telescope (NGST), the SRP effect is larger than all other perturbations and depends mostly on spacecraft attitude. Small variations in the spacecraft attitude are large enough to excite or control the exponential eigenvector. A closed-loop linear controller based on the SRP variations would eliminate one of the largest errors to the orbit and provide a continuous acceleration for use in controlling other disturbances. It is possible to design reference trajectories that account for the periodic lunar and planetary perturbations and still satisfy mission requirements. When such trajectories are used the acceleration required to control the unstable eigenvector is well within the capabilities of a continuous linear controller. Initial estimates show that by using attitude control it should be possible to minimize and even eliminate thruster maneuvers for station keeping.

  17. Air Compressor Pressure Control System Based On Gearshift Integral PID Controller

    OpenAIRE

    PAN Chunyue

    2017-01-01

    The application of gearshift integral PID controller to air compressor pressure control system is introduced, Its kernel is single chip microcomputer PIC16F877.The design of hardware and solfware are introduced too. Practical application shows that this system has many advantages.

  18. Air Compressor Pressure Control System Based On Gearshift Integral PID Controller

    Directory of Open Access Journals (Sweden)

    PAN Chunyue

    2017-01-01

    Full Text Available The application of gearshift integral PID controller to air compressor pressure control system is introduced, Its kernel is single chip microcomputer PIC16F877.The design of hardware and solfware are introduced too. Practical application shows that this system has many advantages.

  19. Pressure control of a pneumatic control system with a long transmission line

    International Nuclear Information System (INIS)

    Jang, Ji Seong; Lee, Kwang Kuk; Choi, Myung Soo

    2003-01-01

    In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, if a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feed forward controller to regulate command following performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model of the transmission line. Therefore, the designed controller can be utilized for the performance improvement of a pressure control system with a long transmission line using compressible fluid

  20. Handheld tympanometer measurements in conscious dogs for the evaluation of the middle ear and auditory tube.

    Science.gov (United States)

    Strain, George M; Fernandes, Asia J

    2015-06-01

    Otitis externa is frequently accompanied by otitis media, yet it can be difficult to evaluate the tympanum, middle ear and auditory tube without the use of advanced radiographic imaging. The objective was to develop techniques for tympanometry testing in conscious dogs and to present normative data for clinical use of this equipment to enable assessment of the tympanum, middle ear and auditory tube. Sixteen hounds (14 female) from a school teaching colony. Dogs were gently restrained in a standing position. After cleaning of the ear canal, a tympanometer probe tip extension was placed in the vertical canal and automated testing performed using a handheld device. Both ears were tested in all dogs. Acceptable recordings were obtained from both ears of 13 dogs, from one ear in each of two dogs and from neither ear of one dog, resulting in data from 28 of 32 (88%) ears. Otoscopic examination confirmed the absence of inflammation or any other obvious explanation for the noncompliant dogs. No significant differences were seen between ears for any measure. Normative data are reported for peak compliance, peak compliance pressure, gradient and ear canal volume. Tympanograms can be recorded in conscious dogs to assist in the evaluation of the middle ear structures. © 2015 ESVD and ACVD.

  1. Perinatal taurine exposure affects adult arterial pressure control

    Science.gov (United States)

    Roysommuti, Sanya; Wyss, J. Michael

    2012-01-01

    Taurine is an abundant free amino acid found in mammalian cells that contributes to many physiologic functions from that of a simple cell osmolyte to a programmer of adult health and disease. Taurine’s contribution extends from conception throughout life, but its most critical exposure period is during perinatal life. In adults, taurine supplementation prevents or alleviates cardiovascular disease and related complications. In contrast, low taurine consumption coincides with increased risk of cardiovascular disease, obesity and type II diabetes. This review focuses on the effects that altered perinatal taurine exposure has on long-term mechanisms that control adult arterial blood pressure and could thereby contribute to arterial hypertension through its ability to program these cardiovascular regulatory mechanisms very early in life. The modifications of these mechanisms can last a lifetime and transfer to the next generation, suggesting that epigenetic mechanisms underlie the changes. The ability of perinatal taurine exposure to influence arterial pressure control mechanisms and hypertension in adult life appears to involve the regulation of growth and development, the central and autonomic nervous system, the renin-angiotensin system, glucose-insulin interaction and changes to heart, blood vessels and kidney function. PMID:23070226

  2. Shape control of slack space reflectors using modulated solar pressure.

    Science.gov (United States)

    Borggräfe, Andreas; Heiligers, Jeannette; Ceriotti, Matteo; McInnes, Colin R

    2015-07-08

    The static deflection profile of a large spin-stabilized space reflector because of solar radiation pressure acting on its surface is investigated. Such a spacecraft consists of a thin reflective circular film, which is deployed from a supporting hoop structure in an untensioned, slack manner. This paper investigates the use of a variable reflectivity distribution across the surface to control the solar pressure force and hence the deflected shape. In this first analysis, the film material is modelled as one-dimensional slack radial strings with no resistance to bending or transverse shear, which enables a semi-analytic derivation of the nominal deflection profile. An inverse method is then used to find the reflectivity distribution that generates a specific, for example, parabolic deflection shape of the strings. Applying these results to a parabolic reflector, short focal distances can be obtained when large slack lengths of the film are employed. The development of such optically controlled reflector films enables future key mission applications such as solar power collection, radio-frequency antennae and optical telescopes.

  3. Ear Injuries (For Parents)

    Science.gov (United States)

    ... pressure isn't equalized, the higher air pressure pushes on one side of the eardrum and causes ... protective equipment every time they practice or play sports — helmets for baseball, softball, hockey, and football; headgear ...

  4. Evaluation of anticipatory signal to steam generator pressure control program for 700 MWe Indian pressurized heavy water reactor

    International Nuclear Information System (INIS)

    Pahari, S.; Hajela, S.; Rammohan, H. P.; Malhotra, P. K.; Ghadge, S. G.

    2012-01-01

    700 MWe Indian Pressurized Heavy Water Reactor (IPHWR) is horizontal channel type reactor with partial boiling at channel outlet. Due to boiling, it has a large volume of vapor present in the primary loops. It has two primary loops connected with the help of pressurizer surge line. The pressurizer has a large capacity and is partly filled by liquid and partly by vapor. Large vapor volume improves compressibility of the system. During turbine trip or load rejection, pressure builds up in Steam Generator (SG). This leads to pressurization of Primary Heat Transport System (PHTS). To control pressurization of SG and PHTS, around 70% of the steam generated in SG is dumped into the condenser by opening Condenser Steam Dump Valves (CSDVs) and rest of the steam is released to the atmosphere by opening Atmospheric Steam Discharge Valves (ASDVs) immediately after sensing the event. This is accomplished by adding anticipatory signal to the output of SG pressure controller. Anticipatory signal is proportional to the thermal power of reactor and the proportionality constant is set so that SG pressure controller's output jacks up to ASDV opening range when operating at 100% FP. To simulate this behavior for 700 MWe IPHWR, Primary and secondary heat transport system is modeled. SG pressure control and other process control program have also been modeled to capture overall plant dynamics. Analysis has been carried out with 3-D neutron kinetics coupled thermal hydraulic computer code ATMIKA.T to evaluate the effect of the anticipatory signal on PHT pressure and over all plant dynamics during turbine trip in 700 MWe IPHWR. This paper brings out the results of the analysis with and without considering anticipatory signal in SG pressure control program during turbine trip. (authors)

  5. Pressure retarded osmosis as a controlling system for traditional renewables

    Science.gov (United States)

    Carravetta, Armando; Fecarotta, Oreste; La Rocca, Michele; Martino, Riccardo

    2015-04-01

    Pressure retarded osmosis (PRO) is a viable but still not diffused form of renewable energy (see Maisonneuve et al., 2015 for a recent literature review). In PRO, water from a low salinity feed solution permeates through a membrane into a pressurized, high salinity draw solution, giving rise to a positive pressure drop; then energy is obtained by depressurizing the permeate through a hydro-turbine and brackish water is discharged. Many technological, environmental and economical aspects are obstacles in the diffusion of PRO, like the vulnerability of the membranes to fouling, the impact of the brackish water on the local marine environment, the high cost of membranes, etc. We are interested in the use of PRO as a combined form of energy with other renewable energy source like solar, wind or mini hydro in water supply networks (WSN). For the wide diffusion of renewables one of the major concerns of commercial power companies is to obtain very stable form of energy to comply with prescriptions of electricity grid operators and with the instant energy demand curve. Renewables are generally very variable form of energy, for the influence of climatic conditions on available power, and of the fluctuation in water demand in WSN. PRO is a very flexible technology where with appropriate turbines and control system power can be varied continuously to compensate for variation of other source of energy. Therefore, PRO is suitable to be used as a balancing system for commercial power system. We will present a simulation of the performance of a PRO used in combination with three different renewables. In the first two scenarios PRO compensate the difference between energy demand and energy production of a solar power plant and hydro power plant in a WSN. In the third scenario PRO is used to compensate daily variation of energy production in a wind power plant. Standard curves of energy production and energy demand for southern Italy are used. In order to control PRO production an

  6. Neonatal Hairy Ear Pinnae and Gestational Diabetes: Just a Coincidence?

    Science.gov (United States)

    Valerio, Enrico; Riello, Laura; Chirico, Michela; Semenzato, Rossella; Cutrone, Mario

    2015-01-01

    A newborn girl of 36 weeks gestation was noted to have several anomalies, including bilateral low ear attachment with ear pinnae hypertrichosis, left preauricular pit, micrognathia, short lingual frenulum, and short neck. Pregnancy history revealed poorly controlled maternal gestational diabetes (GD). Localized hypertrichosis of the ear pinnae may represent a potential marker of GD and thereby alert physicians to suspect other potentially GD-associated conditions such as macrosomia, asphyxia, respiratory distress, hypoglycemia, hypocalcemia, hyperbilirubinemia, polycythemia, hypertrophic cardiomyopathy, and congenital anomalies, particularly those involving the central nervous system. © 2015 Wiley Periodicals, Inc.

  7. Fuzzy logic control for improved pressurizer systems in nuclear power plants

    International Nuclear Information System (INIS)

    Brown, Chris; Gabbar, Hossam A.

    2014-01-01

    Highlights: • Improved performance of the pressurizer system in a CANDU nuclear power plant (NPP). • Inventory control for the pressurizer system in NPP. • Compare fuzzy logic with PID in pressurizer system in NPP. • Develop a fuzzy controller to regulate the pressurizer inventory control. • Compare control performance with current proportional controller used at NPP. - Abstract: The pressurizer system in a CANDU nuclear power plant is responsible for maintaining the pressure of the primary heat transport system to ensure the plant is operated within its safe operating envelope. The inventory control for the pressurizer system use a combination of level sensors, feed valves and bleed valves to ensure that there is adequate room in the pressurizer to accommodate any swell or shrinkage in the PHT system. The Darlington Nuclear Generating Station (DNGS) in Ontario, Canada currently uses a proportional controller for the bleed and feed valves to regulate the pressurizer inventory control which can result in large coolant level overshoot along with excessive settling times. The purpose of this paper is to develop a fuzzy controller to regulate the pressurizer inventory control and compare its performance to the current proportional controller used at DNGS. The simulation of the pressurizer inventory control system shows the fuzzy controller performs better than the proportional controller in terms of settling time and overshoot

  8. Role of skeletal muscle in ear development.

    Science.gov (United States)

    Rot, Irena; Baguma-Nibasheka, Mark; Costain, Willard J; Hong, Paul; Tafra, Robert; Mardesic-Brakus, Snjezana; Mrduljas-Djujic, Natasa; Saraga-Babic, Mirna; Kablar, Boris

    2017-10-01

    The current paper is a continuation of our work described in Rot and Kablar, 2010. Here, we show lists of 10 up- and 87 down-regulated genes obtained by a cDNA microarray analysis that compared developing Myf5-/-:Myod-/- (and Mrf4-/-) petrous part of the temporal bone, containing middle and inner ear, to the control, at embryonic day 18.5. Myf5-/-:Myod-/- fetuses entirely lack skeletal myoblasts and muscles. They are unable to move their head, which interferes with the perception of angular acceleration. Previously, we showed that the inner ear areas most affected in Myf5-/-:Myod-/- fetuses were the vestibular cristae ampullaris, sensitive to angular acceleration. Our finding that the type I hair cells were absent in the mutants' cristae was further used here to identify a profile of genes specific to the lacking cell type. Microarrays followed by a detailed consultation of web-accessible mouse databases allowed us to identify 6 candidate genes with a possible role in the development of the inner ear sensory organs: Actc1, Pgam2, Ldb3, Eno3, Hspb7 and Smpx. Additionally, we searched for human homologues of the candidate genes since a number of syndromes in humans have associated inner ear abnormalities. Mutations in one of our candidate genes, Smpx, have been reported as the cause of X-linked deafness in humans. Our current study suggests an epigenetic role that mechanical, and potentially other, stimuli originating from muscle, play in organogenesis, and offers an approach to finding novel genes responsible for altered inner ear phenotypes.

  9. The Impact of Hearing Protection Devices (HPDs on Blood Pressure in Workers Exposed to Noise: A Cross-sectional Study in a Textile Industry

    Directory of Open Access Journals (Sweden)

    Jafar Akbari

    2018-06-01

    Full Text Available Many studies have reported that exposure to workplace noise leads to increase in blood pressure. The aim of this study was to investigate the effect of hearing protection devices (HPDs including ear plug and ear muff on the systolic and diastolic blood pressures of workers exposed to workplace noise in a textile industry. A total of 120 male workers that exposed to 95 dB noise were investigated in this study. The systolic and diastolic blood pressures of the workers were measured for three situations of earplug, earmuff and earplug along earmuff applications. Data analyses were conducted through SPSS software (version 20 and statistical tests of ANOVA and Independent Sample Tests. The comparison of mean blood pressure in three situations showed that using ear muff had a significant effect on the systolic and diastolic blood pressures in the workers. Furthermore, the use of ear plug only had an effect on the systolic blood pressure. But, the application of ear muff caused to decrease in the systolic and diastolic blood pressures only in the third stage of the study. With regard to the results in this study, in order to control the blood pressure changes of the workers, it is recommended to use ear muff in the textile industry.

  10. "Dog ear" formation after double-stapled low anterior resection as a risk factor for anastomotic disruption.

    Science.gov (United States)

    Roumen, R M; Rahusen, F T; Wijnen, M H; Croiset van Uchelen, F A

    2000-04-01

    The aim of this study was to investigate the possible deleterious effect of the lateral intersecting margins (so-called dog ears) on anastomotic disruption after experimentally performed double-stapled anastomoses. Two groups of double-stapled side-to-end anastomoses were performed using pig small intestines. Group A consisted of 35 circular anastomoses and Group B of 32 double-stapled anastomoses with a bilateral dog ear. In both groups bursting pressures were tested using a water-filled, pressure-controlled automatic pumping system (Hamou Endomat), and special attention was paid to the location(s) in the anastomoses were the disruption(s) occurred. In Group A bursting pressures were significantly higher than in Group B (median pressure, 90 vs. 60 mmHg; P dog ear. We conclude that the lateral intersections of double-stapled anastomoses are a structural weak spot and that the currently most often applied double-stapled anastomosis is a less effective type of anastomosis than a complete circular one. Resolving this technical problem might help to reduce the number of anastomotic disruptions after low anterior resections.

  11. Out-of-office blood pressure: from measurement to control

    Directory of Open Access Journals (Sweden)

    Baguet JP

    2012-05-01

    Full Text Available Jean-Philippe Baguet1,21Department of Cardiology, University Hospital, 2Bioclinic Radiopharmaceutics Laboratory, INSERM U1039, Joseph Fourier University, Grenoble, FranceAbstract: Hypertension is an important risk factor for the development of cardiovascular disease, and is a major cause of morbidity and mortality worldwide. Traditionally, hypertension diagnosis and treatment and clinical evaluations of antihypertensive efficacy have been based on office blood pressure (BP measurements; however, there is increasing evidence that office measures may provide inadequate or misleading estimates of a patient’s true BP status and level of cardiovascular risk. The introduction, and endorsement by treatment guidelines, of 24-hour ambulatory BP monitoring and self (or home BP monitoring has facilitated more reliable and reproducible estimations of true BP, including the identification of white-coat and masked hypertension, and evaluation of BP variability. In addition, ambulatory BP monitoring enables accurate assessment of treatment effectiveness over 24 hours and both ambulatory and self BP monitoring may lead to better tailoring of therapy according to BP profile and concomitant disease. This review describes the clinical benefits and limitations of out-of-office assessments and their applications for effective management of hypertension and attainment of BP control.Keywords: ambulatory, ABPM, SBPM, blood pressure measurement, hypertension

  12. Remote controlled stud bolt handling device for reactor pressure vessel

    International Nuclear Information System (INIS)

    Shindo, Takenori; Shigehiro, Katsuya; Ito, Morio; Okada, Kenji

    1988-01-01

    In nuclear power stations, at the time of regular inspection, the works of opening and fixing the upper covers of reactor pressure vessels are carried out for inspecting the inside of reactor pressure vessels and exchanging fuel rods. These upper covers are fastened with many stud bolts, therefore, the works of opening and fixing require a large amount of labor, and are done under the restricted condition of wearing protective clothings and masks. Babcock Hitachi K.K. has completed the development of a remotely controlled automatic bolt tightenig device for this purpose, therefore, its outline is reported. The conventional method of these works and the problems in it are described. The design of the new device aimed at the parallel execution of cleaning screw threads, loosening and tightening nuts, and taking off and putting on nuts and washers, thus contributing to the shortening of regular inspection period, the reduction of the radiation exposure of workers, and the decrease of the number of workers. The function, reliability and endurance of the new device were confirmed by the verifying test using a device made for trial. The device is composed of a stand, a rail and four stations each with a cleaning unit, a stud tensioner and a nut handling unit. (K.I.)

  13. Diet and Blood Pressure Control in Chinese Canadians: Cultural Considerations.

    Science.gov (United States)

    Zou, Ping

    2017-04-01

    Hypertension is highly prevalent in Chinese Canadians and diet has been identified as an important modifiable risk factor for hypertension. The current anti-hypertensive dietary recommendations in hypertension care guidelines lack examination of cultural factors, are not culturally sensitive to ethnic populations, and cannot be translated to Chinese Canadian populations without cultural considerations. Guided by Leininger's Sunrise Model of culture care theory, this paper investigates how cultural factors impact Chinese Canadians' dietary practice. It is proposed that English language proficiency, health literacy, traditional Chinese diet, migration and acculturation, and Traditional Chinese Medicine influence Chinese Canadians' dietary practices. A culturally congruent nursing intervention should be established and tailored according to related cultural factors to facilitate Chinese Canadians' blood pressure control. In addition, further study is needed to test the model adapted from Sunrise Model and understand its mechanism.

  14. [Is blood pressure control different in women than in men?].

    Science.gov (United States)

    Oliveras, A; Sans-Atxer, L; Vázquez, S

    2015-01-01

    Blood pressure (BP) evolves with age; until the 50's it is higher in men than in women, equaling and even then increasing in women. The prevalence of controlled BP appears to be similar between the sexes, but the prevalence of cardiovascular disease is higher in women than in men. The possibility that BP influences the cardiovascular risk differently according to sex must therefore be considered. While some studies suggest no difference exists, others have shown evidence of an increased risk in women with respect to men despite equal BP. In this way, it seems that the measurement of ambulatory BP, but not office BP, would mark the differences in the association between BP-gender and cardiovascular risk. It should therefore be investigated the possibility of a different BP goal for women and men, especially by evaluating ambulatory BP. Copyright © 2015 SEHLELHA. Published by Elsevier España, S.L.U. All rights reserved.

  15. Weak Frictional Healing as Controlled by Intergranular Pressure Solution

    Science.gov (United States)

    He, C.

    2017-12-01

    Unstable fault slips due to velocity weakening requires a frictional healing effect that is stronger than the instantaneous rate effect. Based on a previous analytical result regarding the healing effect at spherical contacts by intergranular pressure solution (He et al., 2013), we extend the analysis to incorporate the full range of dilatancy angles from π/6 to -π/6, covering uphill and downhill situations of many contacts with different dilatancy angles. Assuming that both healing effect (parameter b) and instantaneous rate effect (parameter a) are controlled by intergranular pressure solution, and averaging over the whole range of dilatancy angle, our analysis derives each of the two effects as a function of temperature. The result shows velocity weakening for friction coefficient>0.274. As hydrothermal conditions are important for deep portion of actual fault zones, the strength of velocity weakening is of interest when the related faulting behavior is concerned. As a measure of the strength of velocity weakening, the derived ratio b/a fully controlled by pressure solution shows an upper bound of 1.22. Data analyses in previous studies on plagioclase (He et al., 2013) and oceanic basalt (Zhang and He, 2017) shows a range of b/a =1.05-1.2, consistent with the analytical result. The valuesrate effect, which reduces b/a to levels below the upper bound. These values are significantly less than in dry experiments on granite by Mitchell et al.(2016), where b/a ranges from 1.54-2.59 as inferred by reanalyzing their stick-slip data at temperatures of 20°C, 500°C and 600°C. Comparison between the two ranges of b/a helps understand the dominant mechanism of frictional healing at contacts, especially under hydrothermal conditions in fault zones. For comparable ratios of system stiffness to the critical value, numerical simulations with a single-degree-of-freedom system show that a smaller b/a significantly reduces the peak slip velocity as a result of reduced period

  16. Nursing Education in High Blood Pressure Control. Report of the Task Force on the Role of Nursing in High Blood Pressure Control.

    Science.gov (United States)

    National Institutes of Health (DHEW), Bethesda, MD. High Blood Pressure Information Center.

    This curriculum guide on high blood pressure (hypertension) for nursing educators has five sections: (1) Introduction and Objectives provides information regarding the establishment and objectives of the National Task Force on the Role of Nursing in High Blood Pressure Control and briefly discusses nursing's role in hypertension control; (2) Goals…

  17. The aquatic tympanic ear: convergent adaptations for underwater hearing in three tetrapods

    DEFF Research Database (Denmark)

    Christensen-Dalsgaard, Jakob; Wahlberg, Magnus; Larsen, Ole Næsbye

    pressure, low particle motion medium, and the consequence is that an efficient underwater ear is sensitive to sound pressure. It is often stated that underwater hearing can work efficiently without a middle ear apparatus by bone conduction, since sound is transmitted from water to inner ear tissue...... is modified (cartilaginous or partly cartilaginous). In all three species, the lowest threshold to underwater sound is at this peak frequency and is around 80 dB re 1 µPa. The sensitivity to sound pressure is slightly lower in water than in air, making underwater hearing much more efficient in terms of sound...

  18. Characteristics of pressure control system on PWR/PHWR in pile loop facility

    International Nuclear Information System (INIS)

    Sarwani; Hendro, P.; Suwoto; Sutrisno

    1998-01-01

    PWR/PHWR in-pile loop facility is used for testing of fuel element bundle which is correspond to the condition of power reactor operation. So, this facility is designed at 150 bar of pressure and 350 o C of temperature. Pressure control system is one of the components of the facility and it is equipped with 6 electrical heaters (30 KW), water spray, pressure and temperature monitors. The characterization test of pressure control system has been carried out with operating of 2 electrical heaters (10 KW). The K eff calculation value is different 5.2% from pressure in the pressure control system can be increased to 160 bar within 27 hours. After the system pressure reached the nominal pressure, the pressure control system was in the steady state condition

  19. Human ear recognition by computer

    CERN Document Server

    Bhanu, Bir; Chen, Hui

    2010-01-01

    Biometrics deals with recognition of individuals based on their physiological or behavioral characteristics. The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. Unlike the fingerprint and iris, it can be easily captured from a distance without a fully cooperative subject, although sometimes it may be hidden with hair, scarf and jewellery. Also, unlike a face, the ear is a relatively stable structure that does not change much with the age and facial expressions. ""Human Ear Recognition by Computer"" is the first book o

  20. The ear region of Latimeria chalumnae: functional and evolutionary implications.

    Science.gov (United States)

    Bernstein, Peter

    2003-01-01

    The anatomy of Latimeria chalumnae has figured prominently in discussions about tetrapod origins. While the gross anatomy of Latimeria is well documented, relatively little is known about its otic anatomy and ontogeny. To examine the inner ear and the otoccipital part of the cranium, a serial-sectioned juvenile coelacanth was studied in detail and a three-dimensional reconstruction was made. The ear of Latimeria shows a derived condition compared to other basal sarcopterygians in having a connection between left and right labyrinths. This canalis communicans is perilymphatic in nature and originates at the transition point of the saccule and the lagena deep in the inner ear, where a peculiar sense end organ can be found. In most gnathostomes the inner ears are clearly separated from each other. A connection occurs in some fishes, e.g. within the Ostariophysi. In the sarcopterygian lineage no connections between the inner ears are known except in the Actinistia. Some fossil actinistians show a posteriorly directed duct lying between the foramen magnum and the notochordal canal, similar to the condition in the ear of Latimeria, so this derived character complex probably developed early in actinistian history. Because some features of the inner ear of Latimeria have been described as having tetrapod affinities, the problem of hearing and the anatomy of the otical complex in the living coelacanth has been closely connected to the question of early tetrapod evolution. It was assumed in the past that the structure found in Latimeria could exemplify a transitional stage in otic evolution between the fishlike sarcopterygians and the first tetrapods in a functional or even phylogenetic way. Here the possibility is considered that the canalis communicans does not possess any auditory function but rather is involved in sensing pressure changes during movements involving the intracranial joint. Earlier hypotheses of a putative tympanic ear are refuted.

  1. Optimization and Control of Pressure Swing Adsorption Processes Under Uncertainty

    KAUST Repository

    Khajuria, Harish; Pistikopoulos, Efstratios N.

    2012-01-01

    The real-time periodic performance of a pressure swing adsorption (PSA) system strongly depends on the choice of key decision variables and operational considerations such as processing steps and column pressure temporal profiles, making its design

  2. A comparison of volume control and pressure-regulated volume control ventilation in acute respiratory failure

    OpenAIRE

    Guldager, Henrik; Nielsen, Soeren L; Carl, Peder; Soerensen, Mogens B

    1997-01-01

    Background: The aim of this study was to test the hypothesis that a new mode of ventilation (pressure-regulated volume control; PRVC) is associated with improvements in respiratory mechanics and outcome when compared with conventional volume control (VC) ventilation in patients with acute respiratory failure. We conducted a randomised, prospective, open, cross over trial on 44 patients with acute respiratory failure in the general intensive care unit of a university hospital. After a stabiliz...

  3. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    lifting and supporting weights) and have an important influence on blood pressure, it is essential to evaluate blood pressure response to iso- metric effort. This test can reveal high blood pressure that might otherwise not be detected. Only a few ...

  4. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    Blood pressure at rest is not predictive of roundthe- clock values. Blood pressure should therefore be measured during effort to evaluate hypertension and its response to treatment. The effect of sustained-release verapamil (240 mg taken once a day) on blood pressure at rest and during isometric effort was therefore ...

  5. Naturopathic treatment for ear pain in children.

    Science.gov (United States)

    Sarrell, E Michael; Cohen, Herman Avner; Kahan, Ernesto

    2003-05-01

    included in the study and recorded all of the data. The presence or absence of ear pain was assessed over 3 days with a visual analog scale. Ear pain was assessed by a specially devised observational instrument based on previous reports. One side of the instrument consisted of a linear numbered scale, from 1 (no pain) to 10 (worst possible pain), and a corresponding color scale, ranging from blue to dark red. The reverse side contained a scale of 5 facial expressions, ranging from broad smile (no pain) to a sad and crying face (worst possible pain), and a corresponding color scale, ranging from blue to dark red. There were no significant between-group differences in patient age or gender, degree of fever, main symptoms, associated symptoms, and severity or laterality of acute otitis media. Each group had a statistically significant improvement in ear pain over the course of the 3 days. Patients who were given ear drops alone had a better response than patients who were given ear drops together with amoxicillin. Results were better in the NHED group than in the controls. Nevertheless, the findings indicated that the pain was mostly (80%) self-limited and could be explained simply by the time elapsed. The American Academy of Otolaryngology-Head and Neck Surgery guidelines recommend topical medications as the first line of treatment for ear pain in the absence of systemic infection or serious underlying disease. Because no evidence was found that systemic antibiotics alone improved treatment outcome, if antibiotics do not change the natural course of otitis media, then the main goal of treatment, as in the present study, should be to alleviate the ear pain. The alternative, naturopathic herbal extract medications, may offer many new possibilities in the management of ear pain associated with AOM. Primary care physicians should be aware that at least 10% of their patients may have tried 1 or more forms of alternative/complementary medicine before presenting for consultation

  6. An Ultra-low Frequency Modal Testing Suspension System for High Precision Air Pressure Control

    Directory of Open Access Journals (Sweden)

    Qiaoling YUAN

    2014-05-01

    Full Text Available As a resolution for air pressure control challenges in ultra-low frequency modal testing suspension systems, an incremental PID control algorithm with dead band is applied to achieve high-precision pressure control. We also develop a set of independent hardware and software systems for high-precision pressure control solutions. Taking control system versatility, scalability, reliability, and other aspects into considerations, a two-level communication employing Ethernet and CAN bus, is adopted to complete such tasks as data exchange between the IPC, the main board and the control board ,and the pressure control. Furthermore, we build a single set of ultra-low frequency modal testing suspension system and complete pressure control experiments, which achieve the desired results and thus confirm that the high-precision pressure control subsystem is reasonable and reliable.

  7. Expression of macrophage migration inhibitory factor and CD74 in the inner ear and middle ear in lipopolysaccharide-induced otitis media.

    Science.gov (United States)

    Ishihara, Hisashi; Kariya, Shin; Okano, Mitsuhiro; Zhao, Pengfei; Maeda, Yukihide; Nishizaki, Kazunori

    2016-10-01

    Significant expression of macrophage migration inhibitory factor and its receptor (CD74) was observed in both the middle ear and inner ear in experimental otitis media in mice. Modulation of macrophage migration inhibitory factor and its signaling pathway might be useful in the management of inner ear inflammation due to otitis media. Inner ear dysfunction secondary to otitis media has been reported. However, the specific mechanisms involved are not clearly understood. The aim of this study is to investigate the expression of macrophage migration inhibitory factor and CD74 in the middle ear and inner ear in lipopolysaccharide-induced otitis media. BALB/c mice received a transtympanic injection of either lipopolysaccharide or phosphate-buffered saline (PBS). The mice were sacrificed 24 h after injection, and temporal bones were processed for polymerase chain reaction (PCR) analysis, histologic examination, and immunohistochemistry. PCR examination revealed that the lipopolysaccharide-injected mice showed a significant up-regulation of macrophage migration inhibitory factor in both the middle ear and inner ear as compared with the PBS-injected control mice. The immunohistochemical study showed positive reactions for macrophage migration inhibitory factor and CD74 in infiltrating inflammatory cells, middle ear mucosa, and inner ear in the lipopolysaccharide-injected mice.

  8. Role of pressure in angiotensin II-induced renal injury: chronic servo-control of renal perfusion pressure in rats.

    Science.gov (United States)

    Mori, Takefumi; Cowley, Allen W

    2004-04-01

    Renal perfusion pressure was servo-controlled chronically in rats to quantify the relative contribution of elevated arterial pressure versus angiotensin II (Ang II) on the induction of renal injury in Ang II-induced hypertension. Sprague-Dawley rats fed a 4% salt diet were administered Ang II for 14 days (25 ng/kg per minute IV; saline only for sham rats), and the renal perfusion pressure to the left kidney was continuously servo-controlled to maintain a normal pressure in that kidney throughout the period of hypertension. An aortic occluder was implanted around the aorta between the two renal arteries and carotid and femoral arterial pressure were measured continuously throughout the experiment to determine uncontrolled and controlled renal perfusion pressure, respectively. Renal perfusion pressure of uncontrolled, controlled, and sham kidneys over the period of Ang II or saline infusion averaged 152.6+/-7.0, 117.4+/-3.5, and 110.7+/-2.2 mm Hg, respectively. The high-pressure uncontrolled kidneys exhibited tubular necrosis and interstitial fibrosis, especially prominent in the outer medullary region. Regional glomerular sclerosis and interlobular artery injury were also pronounced. Controlled kidneys were significantly protected from interlobular artery injury, juxtamedullary glomeruli injury, tubular necrosis, and interstitial fibrosis as determined by comparing the level of injury. Glomerular injury was not prevented in the outer cortex. Transforming growth factor (TGF)-beta and active NF-kappaB proteins determined by immunohistochemistry were colocalized in the uncontrolled kidney in regions of interstitial fibrosis. We conclude that the preferential juxtamedullary injury found in Ang II hypertension is largely induced by pressure and is probably mediated through the TGF-beta and NF-kappaB pathway.

  9. Incorporation of the pressure control system to the classroom simulator

    International Nuclear Information System (INIS)

    Sanchez J, J.

    2004-01-01

    In the nucleo electric centrals, the information systems, support for the decisions making and training are every day more complex and important. The present work is a contribution in this sense, specifically, it is part of a tool of training and analysis developed by the Laboratory of Analysis in Engineering of Nuclear Reactors (LAIRN) of the Faculty of Engineering of the UNAM that consists essentially of a simulator of the Laguna Verde Nucleo electric plant; the classroom simulator, understands the physical systems that compose to the power station and graphic interfaces for its operation and the analysis of results. The project of the classroom simulator is carried out in independent modules that are integrated to the total system as these they are developed and proven. The central objective of this work consists on the development, implementation and it proves of a model of the pressure control system according to the characteristics of the Nucleo electric plant of Laguna Verde, as well as the development of the mimic ones and unfolding necessary graphics to make its interactive operation from sensitive monitors to the tact. The pattern of the control system was developed using as tool the nuclear code of simulation RELAP/SCDAP, designed for the analysis of the types of nuclear reactors more common in occident, and it allows the typical maneuvers in the ways of start up, heating and operation to power, showing an appropriate behavior during the more common operational transitoriness. (Author)

  10. Method of reactivity control in pressure tube reactor

    International Nuclear Information System (INIS)

    Fukumura, Nobuo.

    1988-01-01

    Purpose: To provide a method of controlling reactivity in a pressure tube reactor at high conversion ratio intended for high burn-up degree. Method: Control tubes are inserted in heavy water moderator. Light water is filled in the tubes at the initial burning stage. Along with the advance of the burning, the light water is gradually removed and replaced with gases of less reactive nuclear reactivity with neutrons such as air or gaseous carbon dioxide. The tubes are made of less neutron absorbing material such as aluminum. By filling light water, infinite multiplication factor is reduced to suppress the reactivity at the initial burning stage. As light water is gradually removed and replaced with air, etc., it provides an effect like that elimination of heavy water moderator to increase the conversion ratio. Accordingly, nuclear fission materials are produced additionally by so much to extend the burn-up degree. In this way, it can provide excellent effect in realizing high burn-up ratio and high conversion ratio. (Kamimura, M.)

  11. Software to study the control strategy of pressurized water reactor

    International Nuclear Information System (INIS)

    Oliveira, Jose Ricardo de

    2002-01-01

    The computational program, result of this work, is a tool developed for the study of the control of Pressurized Water Reactors (PWR) constituted by only one coolant loop. The implementation of a user friendly interface for input/output data, makes the program also suitable for training and teaching applications. As design premise, it was considered enough just the modeling of the primary circuit, using as interface with the secondary circuit, a simplified differential equation of the temperature associated with the secondary power. All the incorporated dynamic equations to the model were developed using basic laws of conservation, boundary conditions and hypotheses appropriated to the control study. To arrive to the final model, core thermal and hydraulic characteristics and design data were obtained from of the available bibliography and adapted for a conceptual peculiar design of a small PWR. The whole program and all input/output interfaces were developed using the software Matlab, version 5.L Sub-routines of numeric integration based on the Runge-Kutta 4 method were applied, to solve the set of ordinary differential equations. (author)

  12. Real ear unaided gain and its relation with the equivalent volume of the external and middle ear

    Directory of Open Access Journals (Sweden)

    Bastos, Bárbara Guimarães

    2012-01-01

    Full Text Available Introduction: Old age is associated with changes in the characteristics of the middle ear transmission system and in external ear resonance, and these carry implications for the hearing aid (HA verification process for which targets and measures of the real ear insertion gain (REIG are used. Aim: To compare the real ear unaided gain (REUG and the equivalent volumes of the external ear (VeqEE and the middle ear (VeqME between elderly and adult patients. Methods: This is a retrospective study in which the medical records of 28 elderly patients (aged between 61 and 102 years, average hearing thresholds between 38.75 and 85 dB HL and 23 adult patients (aged 20-59, mean hearing thresholds between 31.25 and 116.25 dB HL with bilateral sensorineural hearing loss and no history of middle ear abnormalities were analyzed. Immittance measurements (VeqEE, VeqME, and pressure of the peak of maximum compliance and the REUG (frequency and amplitude of the primary peak were recovered for a total of 40 ears. These data were compared between elderly and adults as well as between men and women, using Student's t test. Correlations (Pearson between immittance and REUG data were also verified. Results: No statistically significant differences (p < 0.01 were found for immittance and REUG data between elderly and adults, or between men and women. A negative and weak but significant correlation was observed between the REUG primary peak and VeqEE. Conclusion: Hearing aid verification can be performed with target and measures of the REIG in the elderly population.

  13. Reducing energy consumption and leakage by active pressure control in a water supply system

    NARCIS (Netherlands)

    Bakker, M.; Rajewicz, T.; Kien, H.; Vreeburg, J.H.G.; Rietveld, L.C.

    2013-01-01

    WTP Gruszczyn supplies drinking water to a part of the city of Pozna?, in the Midwest of Poland. For the optimal automatic pressure control of the clear water pumping station, nine pressure measuring points were installed in the distribution network, and an active pressure control model was

  14. Analysis of and H∞ Controller Design For An Electro-Hydraulic Servo Pressure Regulator

    DEFF Research Database (Denmark)

    Stubkier, Søren; Pedersen, Henrik C.; Andersen, Torben Ole

    2011-01-01

    -circuit pumps are still hydraulically controlled, there is however still a need for being able to generate a hydraulic pilot pressure. The focus of the current paper is on the analysis and controller design of an electrohydraulic servo pressure regulator, which generates a hydraulic LS-pressure for a variable...

  15. Global Ear. Werke 2001 - 2006

    Index Scriptorium Estoniae

    2006-01-01

    Dresdenis muusikafestivalil "Global Ear" 23.3.03 esitusel Eesti heliloojate muusika: Helena Tulve "lumineux/opaque", Jaan Rääts "Meditation", Mirjam Tally "Aura", Mati Kuulberg "Sonate Nr.4", Mari Vihmand "Seitsmele"

  16. COMMON INFECTIONS OF THE EAR

    African Journals Online (AJOL)

    Enrique

    tion of the skin covering the tympanic membrane and deep exter- nal canal, and the production of ... of combination steroid/antifungal/antibiotic ointment (e.g.. Kenacomb) with a cotton bud ..... protection to the delicate middle ear structures.

  17. Effect of interfacial turbulence and accommodation coefficient on CFD predictions of pressurization and pressure control in cryogenic storage tank

    Science.gov (United States)

    Kassemi, Mohammad; Kartuzova, Olga

    2016-03-01

    Pressurization and pressure control in cryogenic storage tanks are to a large extent affected by heat and mass transport across the liquid-vapor interface. These mechanisms are, in turn, controlled by the kinetics of the phase change process and the dynamics of the turbulent recirculating flows in the liquid and vapor phases. In this paper, the effects of accommodation coefficient and interfacial turbulence on tank pressurization and pressure control simulations are examined. Comparison between numerical predictions and ground-based measurements in two large liquid hydrogen tank experiments, performed in the K-site facility at NASA Glenn Research Center (GRC) and the Multi-purpose Hydrogen Test Bed (MHTB) facility at NASA Marshall Space Flight Center (MSFC), are used to show the impact of accommodation coefficient and interfacial and vapor phase turbulence on evolution of pressure and temperatures in the cryogenic storage tanks. In particular, the self-pressurization comparisons indicate that: (1) numerical predictions are essentially independent of the magnitude of the accommodation coefficient; and (2) surprisingly, laminar models sometimes provide results that are in better agreement with experimental self-pressurization rates, even in parametric ranges where the bulk flow is deemed fully turbulent. In this light, shortcomings of the present CFD models, especially, numerical treatments of interfacial mass transfer and turbulence, as coupled to the Volume-of-Fluid (VOF) interface capturing scheme, are underscored and discussed.

  18. Multidisciplinary Treatment of the Metabolic Syndrome Lowers Blood Pressure Variability Independent of Blood Pressure Control.

    Science.gov (United States)

    Marcus, Yonit; Segev, Elad; Shefer, Gabi; Sack, Jessica; Tal, Brurya; Yaron, Marianna; Carmeli, Eli; Shefer, Lili; Margaliot, Miri; Limor, Rona; Gilad, Suzan; Sofer, Yael; Stern, Naftali

    2016-01-01

    Blood pressure (BP) variability (BPV) contributes to target organ damage independent of BP. The authors examined the effect of a 1-year multidisciplinary intervention on BPV in patients with the metabolic syndrome (MetS) as defined by criteria from the Third Report of the Adult Treatment Panel. Forty-four nondiabetic patients underwent clinical and biochemical profiling, 24-hour ambulatory BP monitoring (ABPM), body composition, carotid intima-media thickness, and carotid-femoral pulse wave velocity (PWV). The intervention targeted all MetS components. BPV was assessed by the standard deviation of daytime systolic BP derived from ABPM. Patients with low and high BPV (lower or higher than the median daytime standard deviation of 11.6 mm Hg) did not differ in regards to systolic and diastolic BP, age, fasting glucose, glycated hemoglobin, and body mass index, but the high-variability group had higher values of low-density lipoprotein and leg fat. The 1-year intervention resulted in weight reduction but not BP-lowering. BPV declined in the high-variability group in association with lowering of PWV, C-reactive protein, glycated hemoglobin, alanine aminotransferase, asymmetric dimethylarginine, and increased high-density lipoprotein cholesterol. A multidisciplinary intervention independent of BP-lowering normalized BPV, lowered PWV, and enhanced metabolic control. © 2015 Wiley Periodicals, Inc.

  19. Radon mitigation with mechanical supply and exhaust ventilation adjusted by a pressure control unit

    International Nuclear Information System (INIS)

    Kokotti, H.; Keskikuru, T.; Kalliokoski, P.

    1993-01-01

    Effective ventilation and positive or low negative pressure indoors are suggested to low indoor radon levels. The aim of this study is to develop and to test an equipment, which makes it possible to achieve simultaneously effective ventilation and minimum outdoor-pressure difference. The unit includes mechanical supply and exhaust air fans, a exchanger and a pressure control unit in direct digital control (DDC), which adjusts continuously air exchange based on the pressure difference transmitter information. (orig.). (8 refs., 6 figs.)

  20. The Healing Effect of Low-Temperature Atmospheric-Pressure Plasma in Pressure Ulcer: A Randomized Controlled Trial.

    Science.gov (United States)

    Chuangsuwanich, Apirag; Assadamongkol, Tananchai; Boonyawan, Dheerawan

    2016-12-01

    Pressure ulcers are difficult to treat. Recent reports of low-temperature atmospheric-pressure plasma (LTAPP) indicated its safe and effectiveness in chronic wound care management. It has been shown both in vitro and vivo studies that LTAPP not only helps facilitate wound healing but also has antimicrobial efficacy due to its composition of ion and electron, free radicals, and ultraviolet ray. We studied the beneficial effect of LTAPP specifically on pressure ulcers. In a prospective randomized study, 50 patients with pressure ulcers were divided into 2 groups: Control group received standard wound care and the study group was treated with LTAPP once every week for 8 consecutive weeks in addition to standard wound care. We found that the group treated with LTAPP had significantly better PUSH (Pressure Ulcer Scale for Healing) scores and exudate amount after 1 week of treatment. There was also a reduction in bacterial load after 1 treatment regardless of the species of bacteria identified.

  1. A comparison of volume control and pressure-regulated volume control ventilation in acute respiratory failure

    Science.gov (United States)

    Guldager, Henrik; Nielsen, Soeren L; Carl, Peder; Soerensen, Mogens B

    1997-01-01

    Background: The aim of this study was to test the hypothesis that a new mode of ventilation (pressure-regulated volume control; PRVC) is associated with improvements in respiratory mechanics and outcome when compared with conventional volume control (VC) ventilation in patients with acute respiratory failure. We conducted a randomised, prospective, open, cross over trial on 44 patients with acute respiratory failure in the general intensive care unit of a university hospital. After a stabilization period of 8 h, a cross over trial of 2 × 2 h was conducted. Apart from the PRVC/VC mode, ventilator settings were comparable. The following parameters were recorded for each patient: days on ventilator, failure in the assigned mode of ventilation (peak inspiratory pressure > 50 cmH2O) and survival. Results: In the crossover trial, peak inspiratory pressure was significantly lower using PRVC than with VC (20 cmH2O vs 24 cmH2O, P < 0.0001). No other statistically significant differences were found. Conclusions: Peak inspiratory pressure was significantly lower during PRVC ventilation than during VC ventilation, and thus PRVC may be superior to VC in certain patients. However, in this small group of patients, we could not demonstrate that PRVC improved outcome. PMID:11056699

  2. DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRES-SURE MONITORING

    Directory of Open Access Journals (Sweden)

    Mansoor Moazenzadeh

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: The study was conducted to define the determinants of suboptimal blood pressure (BP control among hypertensive patients under treatment and explore a predictive model for detecting the patients at risk for increased BP.    METHODS: We enrolled 97 patients (40 males, 57 females under treatment for hypertension between June 2006 and May 2007 in Shafa hospital, Kerman, Iran. BP was measured at clinic twice within 5-minute intervals. After setting up ambulatory blood pressure monitoring (ABPM, BP was measured at 30-minute intervals during the day and 60-minute intervals during the night. The frequency of increased BP (more than 140/90 mmHg was included in a regression model as dependent variable and all the others such as age, sex, body mass index (BMI, drugs and baseline clinical measurements as the predictors.    RESULTS: Increased BP was detected in 44% (95% CI: 38.79%-49.65% of all measurements during 24-hour monitoring. The frequency of increased BP had a significant relationship with BMI (b=0.35, P=0.001. Clinic's pulse pressure was a significant predicting factor for BP increase (P=0.02.    CONCLUSION: BMI and pulse pressure are the best predictors for being hypertensive during lifetime. Ineffective treatment of hypertension is frequent among the hypertensive patients.      Keywords: Blood pressure control, Pulse pressure, Ambulatory blood pressure monitoring (ABPM, BMI.

  3. Effect of a single prophylactic preoperative oral antibiotic dose on surgical site infection following complex dermatological procedures on the nose and ear: a prospective, randomised, controlled, double-blinded trial.

    Science.gov (United States)

    Rosengren, Helena; Heal, Clare F; Buttner, Petra G

    2018-04-19

    There is limited published research studying the effect of antibiotic prophylaxis on surgical site infection (SSI) in dermatological surgery, and there is no consensus for its use in higher-risk cases. The objective of this study was to determine the effectiveness of a single oral preoperative 2 g dose of cephalexin in preventing SSI following flap and graft dermatological closures on the nose and ear. Prospective double-blinded, randomised, placebo-controlled trial testing for difference in infection rates. Primary care skin cancer clinics in North Queensland, Australia, were randomised to 2 g oral cephalexin or placebo 40-60 min prior to skin incision. 154 consecutive eligible patients booked for flap or graft closure following skin cancer excision on the ear and nose. 2 g dose of cephalexin administered 40-60 min prior to surgery. Overall 8/69 (11.6%) controls and 1/73 (1.4%) in the intervention group developed SSI (p=0.015; absolute SSI reduction 10.2%; number needed to treat (NNT) for benefit 9.8, 95% CI 5.5 to 45.5). In males, 7/44 controls and 0/33 in the intervention group developed SSI (p=0.018; absolute SSI reduction 15.9%; NNT for benefit 6.3, 95% CI 3.8 to 19.2). SSI was much lower in female controls (1/25) and antibiotic prophylaxis did not further reduce this (p=1.0). There was no difference between the study groups in adverse symptoms attributable to high-dose antibiotic administration (p=0.871). A single oral 2 g dose of cephalexin given before complex skin closure on the nose and ear reduced SSI. ANZCTR 365115; Post-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Development of Proportional Pressure Control Valve for Hydraulic Braking Actuator of Automobile ABS

    Directory of Open Access Journals (Sweden)

    Che-Pin Chen

    2018-04-01

    Full Text Available This research developed a novel proportional pressure control valve for an automobile hydraulic braking actuator. It also analyzed and simulated solenoid force of the control valves, and the pressure relief capability test of electromagnetic thrust with the proportional valve body. Considering the high controllability and ease of production, the driver of this proportional valve was designed with a small volume and powerful solenoid force to control braking pressure and flow. Since the proportional valve can have closed-loop control, the proportional valve can replace a conventional solenoid valve in current brake actuators. With the proportional valve controlling braking and pressure relief mode, it can narrow the space of hydraulic braking actuator, and precisely control braking force to achieve safety objectives. Finally, the proposed novel proportional pressure control valve of an automobile hydraulic braking actuator was implemented and verified experimentally.

  5. A study on the improvement of the load pressure feedback mechanism of the proportional pressure control valve

    International Nuclear Information System (INIS)

    Oh, In Ho; Jang, Ji Seong; Lee, Ill Yeong; Chung, Dai Jong; Cho, Sung Hyun

    1999-01-01

    The proportional pressure control valve having versatile functions and higher performance is an essential component in the open loop controlled rear wheel steering gear of the four wheel steering system on a passenger car. In this study, the authors suggest a new type of load pressure feedback mechanism which can make it easy change the control range of load pressure without changing the capacity of solenoid. The concept of the suggested mechanism, composed of the pressure chamber with throttles in series, was described. The mathematical model was derived from the rear wheel steering gear system consisting of a valve and a cylinder for the purpose of analyzing the valve characteristics. And the programme for computing the characteristic of the valve was developed. Experiments were carried out to confirm the performance of the valve and computations were performed to ascertain the usefulness of the developed programme. The results from the computations fairly coincide with those from the experiments. The results from the experiments and computations show that the performance of new valve is as good as that of the already developed one and the new valve has an advantage in the easiness in varying the control range of load pressure

  6. 3D Printed Bionic Ears

    Science.gov (United States)

    Mannoor, Manu S.; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A.; Soboyejo, Winston O.; Verma, Naveen; Gracias, David H.; McAlpine, Michael C.

    2013-01-01

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the precise anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing. PMID:23635097

  7. 3D printed bionic ears.

    Science.gov (United States)

    Mannoor, Manu S; Jiang, Ziwen; James, Teena; Kong, Yong Lin; Malatesta, Karen A; Soboyejo, Winston O; Verma, Naveen; Gracias, David H; McAlpine, Michael C

    2013-06-12

    The ability to three-dimensionally interweave biological tissue with functional electronics could enable the creation of bionic organs possessing enhanced functionalities over their human counterparts. Conventional electronic devices are inherently two-dimensional, preventing seamless multidimensional integration with synthetic biology, as the processes and materials are very different. Here, we present a novel strategy for overcoming these difficulties via additive manufacturing of biological cells with structural and nanoparticle derived electronic elements. As a proof of concept, we generated a bionic ear via 3D printing of a cell-seeded hydrogel matrix in the anatomic geometry of a human ear, along with an intertwined conducting polymer consisting of infused silver nanoparticles. This allowed for in vitro culturing of cartilage tissue around an inductive coil antenna in the ear, which subsequently enables readout of inductively-coupled signals from cochlea-shaped electrodes. The printed ear exhibits enhanced auditory sensing for radio frequency reception, and complementary left and right ears can listen to stereo audio music. Overall, our approach suggests a means to intricately merge biologic and nanoelectronic functionalities via 3D printing.

  8. Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System

    Science.gov (United States)

    Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren

    2017-11-01

    The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.

  9. Inner ear anatomy in Waardenburg syndrome: radiological assessment and comparison with normative data.

    Science.gov (United States)

    Kontorinis, Georgios; Goetz, Friedrich; Lanfermann, Heinrich; Luytenski, Stefan; Giesemann, Anja M

    2014-08-01

    As patients with Waardenburg syndrome (WS) represent potential candidates for cochlear implantation, their inner ear anatomy is of high significance. There is an ongoing debate whether WS is related to any inner ear dysplasias. Our objective was to evaluate radiologically the inner ear anatomy in patients with WS and identify any temporal bone malformations. A retrospective case review was carried out in a tertiary, referral center. The high resolution computed tomography (HRCT) scans of the temporal bone from 20 patients (40 ears) with WS who were managed for deafness in a tertiary referral center from 1995 to 2012 were retrospectively examined. Measurements of 15 different inner ear dimensions, involving the cochlea, the vestibule, the semicircular canals and the internal auditory meatus, as well as measurements of the vestibular aqueduct, were performed independently by two neuroradiologists. Finally, we compared the results from the WS group with a control group consisting of 50 normal hearing subjects (100 ears) and with previously reported normative values. Inner ear malformations were not found in any of the patients with WS. All measured inner ear dimensions were within the normative values compiled by our study group as well as by others. Inner ear malformations are not characteristic for all types of WS; however, certain rare subtypes might be related to inner ear deformities. Normative cochleovestibular dimensions that can help in assessing the temporal bone anatomy are provided. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Manufacturing and in vivo inner ear visualization of MRI traceable liposome nanoparticles encapsulating gadolinium

    Directory of Open Access Journals (Sweden)

    Kinnunen Paavo KJ

    2010-12-01

    Full Text Available Abstract Background Treatment of inner ear diseases remains a problem because of limited passage through the blood-inner ear barriers and lack of control with the delivery of treatment agents by intravenous or oral administration. As a minimally-invasive approach, intratympanic delivery of multifunctional nanoparticles (MFNPs carrying genes or drugs to the inner ear is a future therapy for treating inner ear diseases, including sensorineural hearing loss (SNHL and Meniere's disease. In an attempt to track the dynamics and distribution of nanoparticles in vivo, here we describe manufacturing MRI traceable liposome nanoparticles by encapsulating gadolinium-tetra-azacyclo-dodecane-tetra-acetic acid (Gd-DOTA (abbreviated as LPS+Gd-DOTA and their distribution in the inner ear after either intratympanic or intracochlear administration. Results Measurements of relaxivities (r1 and r2 showed that LPS+Gd-DOTA had efficient visible signal characteristics for MRI. In vivo studies demonstrated that LPS+Gd-DOTA with 130 nm size were efficiently taken up by the inner ear at 3 h after transtympanic injection and disappeared after 24 h. With intracochlear injection, LPS+Gd-DOTA were visualized to distribute throughout the inner ear, including the cochlea and vestibule with fast dynamics depending on the status of the perilymph circulation. Conclusion Novel LPS+Gd-DOTA were visible by MRI in the inner ear in vivo demonstrating transport from the middle ear to the inner ear and with dynamics that correlated to the status of the perilymph circulation.

  11. Stimulus-dependent effects on right ear advantage in schizophrenia

    Directory of Open Access Journals (Sweden)

    Smucny J

    2012-09-01

    Full Text Available Jason Smucny,1,3 Korey Wylie,3 Jason Tregellas1–31Neuroscience Program, University of Colorado Anschutz Medical Campus, 2Research Science, Denver VA Medical, Center, 3Department of Psychiatry, University of Colorado Anschutz Medical Campus, Aurora, CO, USABackground: When presented with different sounds in each ear (dichotic listening, healthy subjects typically show a preference for stimuli heard in the right ear, an effect termed "right ear advantage". Previous studies examining right ear advantage in schizophrenia have been inconsistent, showing either decreased or increased advantage relative to comparison subjects. Given evidence for enhanced semantic processing in schizophrenia, some of this inconsistency may be due to the type of stimuli presented (words or syllables. The present study examined right ear advantage in patients and controls using both words and syllables as stimuli.Methods: Right ear advantage was compared between 20 patients with schizophrenia and 17 healthy controls. Two versions of the task were used, ie, a consonant-vowel pairing task and a fused rhymed words task.Results: A significant group × task interaction was observed. Relative to healthy controls, patients showed a greater difference on the syllable-based task compared with the word-based task. The number of distractors marked during the syllable-based task was inversely correlated with score on the Global Assessment of Function Scale.Conclusion: The findings are consistent with a left hemisphere dysfunction in schizophrenia, but also suggest that differences may be stimulus-specific, with a relative sparing of the deficit in the context of word stimuli. Performance may be related to measures of social, occupational, and psychological function.Keywords: schizophrenia, right ear advantage, dichotic, distraction

  12. Pressure Dynamic Characteristics of Pressure Controlled Ventilation System of a Lung Simulator

    Directory of Open Access Journals (Sweden)

    Yan Shi

    2014-01-01

    Full Text Available Mechanical ventilation is an important life support treatment of critically ill patients, and air pressure dynamics of human lung affect ventilation treatment effects. In this paper, in order to obtain the influences of seven key parameters of mechanical ventilation system on the pressure dynamics of human lung, firstly, mechanical ventilation system was considered as a pure pneumatic system, and then its mathematical model was set up. Furthermore, to verify the mathematical model, a prototype mechanical ventilation system of a lung simulator was proposed for experimental study. Last, simulation and experimental studies on the air flow dynamic of the mechanical ventilation system were done, and then the pressure dynamic characteristics of the mechanical system were obtained. The study can be referred to in the pulmonary diagnostics, treatment, and design of various medical devices or diagnostic systems.

  13. Pressure Dynamic Characteristics of Pressure Controlled Ventilation System of a Lung Simulator

    Science.gov (United States)

    Shi, Yan; Ren, Shuai; Cai, Maolin; Xu, Weiqing; Deng, Qiyou

    2014-01-01

    Mechanical ventilation is an important life support treatment of critically ill patients, and air pressure dynamics of human lung affect ventilation treatment effects. In this paper, in order to obtain the influences of seven key parameters of mechanical ventilation system on the pressure dynamics of human lung, firstly, mechanical ventilation system was considered as a pure pneumatic system, and then its mathematical model was set up. Furthermore, to verify the mathematical model, a prototype mechanical ventilation system of a lung simulator was proposed for experimental study. Last, simulation and experimental studies on the air flow dynamic of the mechanical ventilation system were done, and then the pressure dynamic characteristics of the mechanical system were obtained. The study can be referred to in the pulmonary diagnostics, treatment, and design of various medical devices or diagnostic systems. PMID:25197318

  14. Pressure dynamic characteristics of pressure controlled ventilation system of a lung simulator.

    Science.gov (United States)

    Shi, Yan; Ren, Shuai; Cai, Maolin; Xu, Weiqing; Deng, Qiyou

    2014-01-01

    Mechanical ventilation is an important life support treatment of critically ill patients, and air pressure dynamics of human lung affect ventilation treatment effects. In this paper, in order to obtain the influences of seven key parameters of mechanical ventilation system on the pressure dynamics of human lung, firstly, mechanical ventilation system was considered as a pure pneumatic system, and then its mathematical model was set up. Furthermore, to verify the mathematical model, a prototype mechanical ventilation system of a lung simulator was proposed for experimental study. Last, simulation and experimental studies on the air flow dynamic of the mechanical ventilation system were done, and then the pressure dynamic characteristics of the mechanical system were obtained. The study can be referred to in the pulmonary diagnostics, treatment, and design of various medical devices or diagnostic systems.

  15. Role of pressuriser in enhancing pressure control system capability in primary system of 500 MWe PHWR

    Energy Technology Data Exchange (ETDEWEB)

    Walia, M P.S.; Misri, Vijay; Bapat, C N; Sharma, V K [Nuclear Power Corporation, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    The primary heat transport system of a pressurized heavy water reactor (PHWR) extracts and transports the heat produced in the fuel (located inside coolant channel assemblies) to the steam generators where steam is generated to run the turbo-generator. The heat transport medium (primary coolant) is heavy water which is kept in a pressurized liquid state with the help of a pressure control system. Feed and bleed circuits with associated equipment of PHT main system have traditionally constituted the pressure control system. However, for large size reactors of 500 MWe capacity, a surge tank known as pressurizer was incorporated due to the presence of relatively large inventory in PHT main circuit. The pressurizer acts as a cushion for pressure variations resulting from various transients. This significantly reduces the onerous demand on feed and bleed system, thereby reducing reactor outages on system pressure excursions. The paper describes in detail the pressure control system of 500 MWe PHWR involving pressuriser and feed and bleed system including their functions and instrumentation. The results of mathematical modelling/analysis undertaken to establish the response adequacy of pressure control system, to postulated plant transients vis-a-vis the role of pressurizer are presented. (author). 10 figs.

  16. Efect of Pressure-Drop Rate on the Isolation of Cananga Oil using Instantaneous Controlled Pressure-Drop Process.

    Czech Academy of Sciences Publication Activity Database

    Kristiawan, M.; Sobolík, Václav; Al-Haddad, M.; Allaf, K.

    2008-01-01

    Roč. 47, 1 (2008) , s. 66-75 ISSN 0255-2701 Institutional research plan: CEZ:AV0Z40720504 Keywords : cananga oil * essential oil isolation * instantaneous controlled pressure drop (DIC) Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.518, year: 2008

  17. CMC blade with pressurized internal cavity for erosion control

    Science.gov (United States)

    Garcia-Crespo, Andres; Goike, Jerome Walter

    2016-02-02

    A ceramic matrix composite blade for use in a gas turbine engine having an airfoil with leading and trailing edges and pressure and suction side surfaces, a blade shank secured to the lower end of each airfoil, one or more interior fluid cavities within the airfoil having inlet flow passages at the lower end which are in fluid communication with the blade shank, one or more passageways in the blade shank corresponding to each one of the interior fluid cavities and a fluid pump (or compressor) that provides pressurized fluid (nominally cool, dry air) to each one of the interior fluid cavities in each airfoil. The fluid (e.g., air) is sufficient in pressure and volume to maintain a minimum fluid flow to each of the interior fluid cavities in the event of a breach due to foreign object damage.

  18. Pressure Control In A Tyre Of Moving Vehicle

    Science.gov (United States)

    Gawande, Kshitij P.; Jawanjal, Vaishakh A.

    2012-08-01

    We always try to make everything perfect around us and there is major problem still remaining in our automobiles, a puncture in a tire while running. We have developed tubeless tires but thatís not a perfect solution, so there is a serious need of improvement in this area. In this paper the compressed air is used to maintain the pressure in the tire using pneumatic pipes. This is a very basic concept which uses compressor power to maintain the pressure of a tire, while running using pressure gauges and leak proof connection. This technique allows us to drive a punctured vehicle which increases safety, comfort & saves time. This paper suggests a new technique towards one more improvement in our automobile industry.

  19. Blood pressure control among patients with hypertension and newly diagnosed diabetes.

    Science.gov (United States)

    Choma, N N; Griffin, M R; Kaltenbach, L A; Greevy, R A; Roumie, C L

    2012-09-01

    To determine the proportion of patients who achieved blood pressure control during the 2 years following new diabetes diagnosis. A retrospective cohort of veterans ≥ 18 years with hypertension who initiated a diabetes medication from 2000 to 2007 in the Veterans Administration Mid-South Network was assembled. Blood pressure control at diabetes treatment initiation (baseline) was compared with blood pressure control 6, 12, 18 and 24 months later. The Veterans Affairs and American Diabetes Association definitions of control, ≤ 140/90 and ≤ 130/80 mmHg, respectively, were primary and secondary outcomes. At baseline, 59.5% of 16,182 patients had controlled blood pressure according to the Veterans Affairs guideline (31.5% using American Diabetes Association definition). Six months following initiation of diabetes treatment, 65.7% had their blood pressure controlled (P < 0.001). Blood pressure control was sustained but not further improved between 6 months and 2 years, with 66.5% controlled at 2 years following baseline. Higher initial systolic blood pressure, black race and hospitalization in the previous year were associated with higher likelihood of uncontrolled blood pressure at 6 months; whereas baseline cardiovascular disease, baseline dementia and later year of cohort entry were associated with lower likelihood of uncontrolled blood pressure. We found an increase in blood pressure control in the 6 months following initiation of diabetes treatment. However, overall blood pressure control remained suboptimal and with no further improvement over the next 18 months. Published 2011. This article is a US Government work and is in the public domain in the USA.

  20. In-the-Ear Hearing-Instrument Antenna for ISM-Band Body-Centric Ear-to-Ear Communications

    DEFF Research Database (Denmark)

    Yatman, William H.; Larsen, Lauge K; Kvist, Søren Helstrup

    2012-01-01

    A compact 2.45 GHz slot-loop antenna is implemented for the use in the outer shell of an in-the-ear (ITE) hearing instrument (HI). The antenna is optimized for high ear-to-ear path gain (jS21j). The antenna simulation results are presented for two identical antennas, one placed in the center of e...

  1. Performance of a digital PCO2/SPO2 ear sensor.

    Science.gov (United States)

    Kocher, Serge; Rohling, Roman; Tschupp, Andres

    2004-04-01

    For determining the adequacy of ventilation, conventional pulse oximetry should be amended by PaCO2 (= arterial carbon dioxide partial pressure). This study investigates the precision of carbon dioxide measurements of the first digital ear-clip sensor providing continuous non-invasive monitoring of PaCO2, SpO2 (= functional arterial oxygen saturation as estimated with a pulse oximeter) and pulse rate and compares it to two conventional analog oximeters. 30 hypoxemia episodes in 6 adult volunteers were investigated in a standardized protocol. Masimo analog finger sensor, Nellcor analog ear sensor, SenTec digital ear sensor. The difference between PCO2 data (= PaCO2 estimated from the measured PcCO2 based on an algorithm by Severinghaus) (PcCO2 = cutaneous carbon dioxide pressure) and the PaCO2 is clinically unimportant. Therefore, we suggest, the two methods of estimating patient's carbon dioxide status can be used interchangeably. Combined digital SpO2/ PcCO2 ear sensors are very promising to allow for a fast and reliable monitoring of patient's oxygenation, hyper-/hypocapnia and ventilation with one single non-invasive probe. Optimal primary signal processing--amplification and digitalisation within the probe--allow for fast and reliable downstream signal processing algorithms. The resulting short SpO2 response times give the medical staff more time to take appropriate actions.

  2. Improving urban African Americans' blood pressure control through multi-level interventions in the Achieving Blood Pressure Control Together (ACT) study: a randomized clinical trial.

    Science.gov (United States)

    Ephraim, Patti L; Hill-Briggs, Felicia; Roter, Debra L; Bone, Lee R; Wolff, Jennifer L; Lewis-Boyer, LaPricia; Levine, David M; Aboumatar, Hanan J; Cooper, Lisa A; Fitzpatrick, Stephanie J; Gudzune, Kimberly A; Albert, Michael C; Monroe, Dwyan; Simmons, Michelle; Hickman, Debra; Purnell, Leon; Fisher, Annette; Matens, Richard; Noronha, Gary J; Fagan, Peter J; Ramamurthi, Hema C; Ameling, Jessica M; Charlston, Jeanne; Sam, Tanyka S; Carson, Kathryn A; Wang, Nae-Yuh; Crews, Deidra C; Greer, Raquel C; Sneed, Valerie; Flynn, Sarah J; DePasquale, Nicole; Boulware, L Ebony

    2014-07-01

    Given their high rates of uncontrolled blood pressure, urban African Americans comprise a particularly vulnerable subgroup of persons with hypertension. Substantial evidence has demonstrated the important role of family and community support in improving patients' management of a variety of chronic illnesses. However, studies of multi-level interventions designed specifically to improve urban African American patients' blood pressure self-management by simultaneously leveraging patient, family, and community strengths are lacking. We report the protocol of the Achieving Blood Pressure Control Together (ACT) study, a randomized controlled trial designed to study the effectiveness of interventions that engage patient, family, and community-level resources to facilitate urban African American hypertensive patients' improved hypertension self-management and subsequent hypertension control. African American patients with uncontrolled hypertension receiving health care in an urban primary care clinic will be randomly assigned to receive 1) an educational intervention led by a community health worker alone, 2) the community health worker intervention plus a patient and family communication activation intervention, or 3) the community health worker intervention plus a problem-solving intervention. All participants enrolled in the study will receive and be trained to use a digital home blood pressure machine. The primary outcome of the randomized controlled trial will be patients' blood pressure control at 12months. Results from the ACT study will provide needed evidence on the effectiveness of comprehensive multi-level interventions to improve urban African American patients' hypertension control. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Digital Active Noise Reduction Ear Plugs

    National Research Council Canada - National Science Library

    Harley, Thomas

    1994-01-01

    .... In contrast to available ANR headsets that implement fixed analog filters, the prototype defines a digital filter that is optimally defined for the user's current acoustical environment. An above-the-ear (ATE) and an in-the-ear (ITE...

  4. Middle ear infection (otitis media) (image)

    Science.gov (United States)

    Otitis media is an inflammation or infection of the middle ear. Acute otitis media (acute ear infection) occurs when there is ... which causes production of fluid or pus. Chronic otitis media occurs when the eustachian tube becomes blocked ...

  5. External ear: An analysis of its uniqueness

    Directory of Open Access Journals (Sweden)

    Ruma Purkait

    2016-06-01

    Hence, the individuality of every ear has been confirmed which may find use in personal identification studies. The study is a step towards providing scientific support for admitting ear evidence in the Court of Law.

  6. Patient related factors for optimal blood pressure control in patients ...

    African Journals Online (AJOL)

    EB

    2013-09-03

    Sep 3, 2013 ... e” 90 mm Hg.8. Interview questionnaires. The questionnaires during the interview were comprised of four categories. The first was in relation to formal .... high blood pressure in clinics and hospitals is a major cause. Our earlier study on a rural Australian population showed that 56.7% of the patients with.

  7. Blood Pressure Control among Treated Hypertensives in a Tertiary ...

    African Journals Online (AJOL)

    Background: Goal blood pressure (BP) was defined by the JNC VI and the World Health Organization- International Society of Hypertension (WHO/ISH) as <140 mm Hg systolic and <90 mm Hg diastolic for the general and <130 mm Hg systolic and <85 mm Hg diastolic for special high-risk populations. It is well established ...

  8. Comparison of sound transmission in human ears and coupler loaded by audiometric earphones

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2005-01-01

    in the coupler, but since the "ear canal entrance" is not well-defined for the coupler, the mentioned measurements were done at different depths in the coupler. The sound transmission and coupling were described in terms of the pressure division at the entrance of the ear canal and the transmissions in human......, the differences among earphones as well as between human ears and the coupler affect the results of audiometric measurements inducing uncertainty. The influence of these differences is examined by investigating the sound transmission in both human ears and standardized coupler loaded by different audiometric......The thresholds of hearing are usually determined using audiometric earphones. They are calibrated by means of a standardized acoustical coupler. In order to have determined thresholds independent of the earphone type, the coupler should approximate the average human ear closely. Nevertheless...

  9. Proteomics and the Inner Ear

    Directory of Open Access Journals (Sweden)

    Isolde Thalmann

    2001-01-01

    Full Text Available The inner ear, one of the most complex organs, contains within its bony shell three sensory systems, the evolutionary oldest gravity receptor system, the three semicircular canals for the detection of angular acceleration, and the auditory system - unrivaled in sensitivity and frequency discrimination. All three systems are susceptible to a host of afflictions affecting the quality of life for all of us. In the first part of this review we present an introduction to the milestones of inner ear research to pave the way for understanding the complexities of a proteomics approach to the ear. Minute sensory structures, surrounded by large fluid spaces and a hard bony shell, pose extreme challenges to the ear researcher. In spite of these obstacles, a powerful preparatory technique was developed, whereby precisely defined microscopic tissue elements can be isolated and analyzed, while maintaining the biochemical state representative of the in vivo conditions. The second part consists of a discussion of proteomics as a tool in the elucidation of basic and pathologic mechanisms, diagnosis of disease, as well as treatment. Examples are the organ of Corti proteins OCP1 and OCP2, oncomodulin, a highly specific calcium-binding protein, and several disease entities, Meniere's disease, benign paroxysmal positional vertigo, and perilymphatic fistula.

  10. The Impact of Social Pressure and Monetary Incentive on Cognitive Control.

    Science.gov (United States)

    Ličen, Mina; Hartmann, Frank; Repovš, Grega; Slapničar, Sergeja

    2016-01-01

    We compare the effects of two prominent organizational control mechanisms-social pressure and monetary incentive-on cognitive control. Cognitive control underlies the human ability to regulate thoughts and actions in the pursuit of behavioral goals. Previous studies show that monetary incentives can contribute to goal-oriented behavior by activating proactive control. There is, however, much less evidence of how social pressure affects cognitive control and task performance. In a within-subject experimental design, we tested 47 subjects performing the AX-CPT task to compare the activation of cognitive control modes under social pressure and monetary incentive beyond mere instructions to perform better. Our results indicate that instructing participants to improve their performance on its own leads to a significant shift from a reactive to a proactive control mode and that both social pressure and monetary incentive further enhance performance.

  11. Can Loud Music Hurt My Ears?

    Science.gov (United States)

    ... Videos for Educators Search English Español Can Loud Music Hurt My Ears? KidsHealth / For Kids / Can Loud Music Hurt My Ears? Print en español La música ... up? Oh! You want to know if loud music can hurt your ears . Are you asking because ...

  12. Analysis of pressure losses in the diffuser of a control valve

    Science.gov (United States)

    Turecký, Petr; Mrózek, Lukáš; Tajč, Ladislav; Kolovratník, Michal

    The pressure loss in the diffuser of a control valve is evaluated by using CFD computations. Pressure ratios and lifts of a cone for the recommended flow characteristics of an experimental turbine are considered. The pressure loss in a valve is compared with the pressure loss in a nozzle, i.e. the embodiment of the valve without a cone. Computations are carried out for the same mass flow. Velocity profiles are evaluated in both versions of computations. Comparison of computed pressure losses, with the loss evaluated by using relations for diffusers with the ideal velocity conditions in the input cross-section, is carried out.

  13. Analysis of pressure losses in the diffuser of a control valve

    Directory of Open Access Journals (Sweden)

    Turecký Petr

    2017-01-01

    Full Text Available The pressure loss in the diffuser of a control valve is evaluated by using CFD computations. Pressure ratios and lifts of a cone for the recommended flow characteristics of an experimental turbine are considered. The pressure loss in a valve is compared with the pressure loss in a nozzle, i.e. the embodiment of the valve without a cone. Computations are carried out for the same mass flow. Velocity profiles are evaluated in both versions of computations. Comparison of computed pressure losses, with the loss evaluated by using relations for diffusers with the ideal velocity conditions in the input cross-section, is carried out.

  14. Controlling a Conventional LS-pump based on Electrically Measured LS-pressure

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben Ole; Hansen, Michael Rygaard

    2008-01-01

    As a result of the increasing use of sensors in mobile hydraulic equipment, the need for hydraulic pilot lines is decreasing, being replaced by electrical wiring and electrically controllable components. For controlling some of the existing hydraulic components there are, however, still a need...... this system, by either generating a copy of the LS-pressure, the LS-pressure being the output, or letting the output be the pump pressure. The focus of the current paper is on the controller design based on the first approach. Specifically a controlled leakage flow is used to avoid the need for a switching...

  15. Automated Control of Endotracheal Tube Cuff Pressure during Simulated Flight

    Science.gov (United States)

    2016-06-21

    accomplished in the intensive care unit (ICU) with stand-alone devices as well as those integral to a ventilator [13,14]. We hypothesized that closed loop ... Administration approved automatic cuff pressure adjustment devices (Intellicuff, Hamilton Medical , Reno, NV; Pyton, ARM Medical , Bristol, CT; Cuff Sentry, Outcome...711th Human Performance Wing U.S. Air Force School of Aerospace Medicine Int’l Expeditionary Educ & Training Dept Air Force Expeditionary Medical

  16. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Directory of Open Access Journals (Sweden)

    Senn Oliver

    2010-04-01

    Full Text Available Abstract Background Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Objective Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Outcome Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary. Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries. Methods/Design Randomised controlled study. Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system. Expected results/conclusion The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range ≤ 140/≤ 90 mmHg, yellow: blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg lead to better self-monitoring compared with the conventional (non-colour-coded blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. Trial registration ClinicalTrials.gov ID NCT01013467

  17. [Vascular adrenal cyst causing difficult to control high blood pressure].

    Science.gov (United States)

    García Escudero, D; Torres Roca, M; Hernández Contreras, M E; Sánchez Rodríguez, C; Oñate Celdrán, J

    Hypertension is a prevalent disease in developed countries. Adrenal masses, and especially adrenal cysts, are a rare and usually asymptomatic finding, which can go unnoticed or be detected as incidental findings in imaging tests. These circumstances make the multidisciplinary approach mandatory. The case is presented on a 72 year-old woman with uncontrolled high blood pressure referred to the Urology Department due to the incidental finding of a right retroperitoneal mass. A functional and imaging study was performed, establishing a diagnosis of adrenal cyst causing hypertensive symptoms. A literature search was performed in order to assess diagnostic and therapeutic approaches. With the diagnosis of adrenal cyst causing uncontrolled high blood pressure, a right laparoscopic adrenalectomy was performed. After surgery the patient has maintained blood pressure within the normal range. A multidisciplinary approach is necessary for the management of rare diseases. The surgical approach, if possible, should be laparoscopic. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. CFD simulation of flow-pressure characteristics of a pressure control valve for automotive fuel supply system

    International Nuclear Information System (INIS)

    Wu, Dazhuan; Li, Shiyang; Wu, Peng

    2015-01-01

    Highlights: • Direct CFD method for flow-pressure characteristic of a pressure control valve. • Fitted and interpreted the constants of the spool hydraulic force equation. • Established a flow coefficient function of both valve opening and pressure drop. • Developed an indirect CFD method based on the valve-governing equations. - Abstract: This study aims to elaborate on specific computational fluid dynamics (CFD) simulation methods for fitting the flow-pressure curve of a pressure control valve, which is spring-load valve widely used in the automotive fuel supply system. Given that the couple mechanism exists between the flow field in the valve and the spring system, numerous researchers chose to fit the characteristic curve with experimental approaches but scarcely focused on CFD methods. A direct CFD method is introduced in this study to solve this problem. Two evaluation criteria are used to determine whether the internal flow is physically real. An experiment is conducted to verify the simulation results, and the accuracy of this CFD method is proved. However, it is designed to solve one operating condition with fixed spring parameters and the accuracy depends on the amount of operating conditions. Thus, an indirect CFD method is developed based on the well-elaborated valve-governing equations to improve the efficiency and broaden the application extension. This method aims to simulate the exact value of the equation constants to uncouple the flow by numerical method. It is capable of dealing with changed operating conditions and varied spring parameters, and the results are also verified. The visualization of the internal flow provides a better understanding of the flow fields in the valve. The valve gap directly influences the hydraulic force distribution on the spool and causes most pressure loss. The physical meaning of the function constants are explained based on the flow analysis

  19. A pilot randomised controlled trial of negative pressure wound therapy to treat grade III/IV pressure ulcers [ISRCTN69032034

    Science.gov (United States)

    2012-01-01

    Background Negative pressure wound therapy (NPWT) is widely promoted as a treatment for full thickness wounds; however, there is a lack of high-quality research evidence regarding its clinical and cost effectiveness. A trial of NPWT for the treatment of grade III/IV pressure ulcers would be worthwhile but premature without assessing whether such a trial is feasible. The aim of this pilot randomised controlled trial was to assess the feasibility of conducting a future full trial of NPWT for the treatment of grade III and IV pressure ulcers and to pilot all aspects of the trial. Methods This was a two-centre (acute and community), pilot randomised controlled trial. Eligible participants were randomised to receive either NPWT or standard care (SC) (spun hydrocolloid, alginate or foam dressings). Outcome measures were time to healing of the reference pressure ulcer, recruitment rates, frequency of treatment visits, resources used and duration of follow-up. Results Three hundred and twelve patients were screened for eligibility into this trial over a 12-month recruitment period and 12/312 participants (3.8%) were randomised: 6 to NPWT and 6 to SC. Only one reference pressure ulcer healed (NPWT group) during follow-up (time to healing 79 days). The mean number of treatment visits per week was 3.1 (NPWT) and 5.7 (SC); 6/6 NPWT and 1/6 SC participants withdrew from their allocated trial treatment. The mean duration of follow-up was 3.8 (NPWT) and 5.0 (SC) months. Conclusions This pilot trial yielded vital information for the planning of a future full study including projected recruitment rate, required duration of follow-up and extent of research nurse support required. Data were also used to inform the cost-effectiveness and value of information analyses, which were conducted alongside the pilot trial. Trial registration Current Controlled Trials ISRCTN69032034. PMID:22839453

  20. A pilot randomised controlled trial of negative pressure wound therapy to treat grade III/IV pressure ulcers [ISRCTN69032034

    Directory of Open Access Journals (Sweden)

    Ashby Rebecca L

    2012-07-01

    Full Text Available Abstract Background Negative pressure wound therapy (NPWT is widely promoted as a treatment for full thickness wounds; however, there is a lack of high-quality research evidence regarding its clinical and cost effectiveness. A trial of NPWT for the treatment of grade III/IV pressure ulcers would be worthwhile but premature without assessing whether such a trial is feasible. The aim of this pilot randomised controlled trial was to assess the feasibility of conducting a future full trial of NPWT for the treatment of grade III and IV pressure ulcers and to pilot all aspects of the trial. Methods This was a two-centre (acute and community, pilot randomised controlled trial. Eligible participants were randomised to receive either NPWT or standard care (SC (spun hydrocolloid, alginate or foam dressings. Outcome measures were time to healing of the reference pressure ulcer, recruitment rates, frequency of treatment visits, resources used and duration of follow-up. Results Three hundred and twelve patients were screened for eligibility into this trial over a 12-month recruitment period and 12/312 participants (3.8% were randomised: 6 to NPWT and 6 to SC. Only one reference pressure ulcer healed (NPWT group during follow-up (time to healing 79 days. The mean number of treatment visits per week was 3.1 (NPWT and 5.7 (SC; 6/6 NPWT and 1/6 SC participants withdrew from their allocated trial treatment. The mean duration of follow-up was 3.8 (NPWT and 5.0 (SC months. Conclusions This pilot trial yielded vital information for the planning of a future full study including projected recruitment rate, required duration of follow-up and extent of research nurse support required. Data were also used to inform the cost-effectiveness and value of information analyses, which were conducted alongside the pilot trial. Trial registration Current Controlled Trials ISRCTN69032034.

  1. Inner Ear Barotrauma After Underwater Pool Competency Training Without the Use of Compressed Air Case and Review.

    Science.gov (United States)

    McIntire, Sean; Boujie, Lee

    2016-01-01

    Inner ear barotrauma can occur when the gas-filled chambers of the ear have difficulty equalizing pressure with the outside environment after changes in ambient pressure. This can transpire even with small pressure changes. Hypobaric or hyperbaric environments can place significant stress on the structures of the middle and inner ear. If methods to equalize pressure between the middle ear and other connected gas-filled spaces (i.e., Valsalva maneuver) are unsuccessful, middle ear overpressurization can occur. This force can be transmitted to the fluid-filled inner ear, making it susceptible to injury. Damage specifically to the structures of the vestibulocochlear system can lead to symptoms of vertigo, hearing loss, and tinnitus. This article discusses the case of a 23-year-old male Marine who presented with symptoms of nausea and gait instability after performing underwater pool competency exercises to a maximum depth of 13 feet, without breathing compressed air. Diagnosis and management of inner ear barotrauma are reviewed, as is differentiation from inner ear decompression sickness. 2016.

  2. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial

    DEFF Research Database (Denmark)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter

    2018-01-01

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark....... One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent...... a reduction of blood pressure. Clinical Trials NCT00244660....

  3. Heel ulcers - Pressure ulcers or symptoms of peripheral arterial disease? An exploratory matched case control study.

    Science.gov (United States)

    Twilley, Heidi; Jones, Sarahjane

    2016-05-01

    To investigate the relationship between pressure ulcers of the heel and peripheral arterial disease (PAD) and determine the feasibility of conducting a statistically powered matched case control study. Evidence indicates a relationship between chronic leg ulcers and vascular disease. The relationship between pressure ulcers of the heel and vascular disease is less well established. A matched case control study. Data were collected between March 2014 and January 2015. 15 patients identified as having a grade 2, 3 or 4 pressure ulcer of the heel were compared with 15 matched controls without pressure ulcers of the heel. The primary clinical outcome measure was the ankle brachial pressure index (ABPI), where an ABPI 1.3 was considered clinically indicative of PAD. The primary feasibility outcome measure was the rate of recruitment. Eighty seven patients were reported as having foot and heel ulcers; 36 of whom were identified as having pressure ulcers of the heel, 15 (42%) of whom were recruited to the study. Patients presenting with pressure ulcers of the heel were significantly more likely to simultaneously have previously undiagnosed PAD compared with age, gender and ethnicity matched controls without pressure ulcers of the heel (odds ratio: 11, 95% confidence interval 1.99-60.57). The formation of pressure ulcers of the heel could, in some patients, be related to the presence of PAD rather than a consequence of poor quality care. Healthcare professionals should assess the patient to exclude or confirm PAD. Copyright © 2016 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  4. CoCo trial: Color-coded blood pressure Control, a randomized controlled study

    Directory of Open Access Journals (Sweden)

    Chmiel C

    2014-10-01

    Full Text Available Corinne Chmiel, Oliver Senn, Thomas Rosemann, Valerio Del Prete, Claudia Steurer-Stey Institute of General Practice and Health Services Research, University of Zurich, Zurich, Switzerland Background: Inadequate blood pressure (BP control is a frequent challenge in general practice. The objective of this study was to determine whether a color-coded BP booklet using a traffic light scheme (red, >180 mmHg systolic BP and/or >110 mmHg diastolic BP; yellow, >140–180 mmHg systolic BP or >90–110 mmHg diastolic BP; green, ≤140 mmHg systolic BP and ≤90 mmHg diastolic BP improves BP control and adherence with home BP measurement.Methods: In this two-group, randomized controlled trial, general practitioners recruited adult patients with a BP >140 mmHg systolic and/or >90 mmHg diastolic. Patients in the control group received a standard BP booklet and the intervention group used a color-coded booklet for daily home BP measurement. The main outcomes were changes in BP, BP control (treatment goal <140/90 mmHg, and adherence with home BP measurement after 6 months.Results: One hundred and twenty-one of 137 included patients qualified for analysis. After 6 months, a significant decrease in systolic and diastolic BP was achieved in both groups, with no significant difference between the groups (16.1/7.9 mmHg in the intervention group versus 13.1/8.6 mmHg in the control group, P=0.3/0.7. BP control (treatment target <140/90 mmHg was achieved significantly more often in the intervention group (43% versus 25%; P=0.037; number needed to treat of 5. Adherence with home BP measurement overall was high, with a trend in favor of the intervention group (98.6% versus 96.2%; P=0.1Conclusion: Color-coded BP self-monitoring significantly improved BP control (number needed to treat of 5, meaning that every fifth patient utilizing color-coded self-monitoring achieved better BP control after 6 months, but no significant between-group difference was

  5. On-off controller for installation to test the pressurized water reactor material

    International Nuclear Information System (INIS)

    Zauq, M.H.

    1982-05-01

    This report describes the design of an ON-OFF controller based on the 6800 microprocessor in its assembly language and its interfacing with its environment (sensors, periphery, etc). The controller is meant to control the temperature and the pressure inside an experimental chamber in which the material under test is placed. The ''Design basis accident'' conditions (e.g., LOCA) for a pressurized water reactor are simulated in the experimental chamber [fr

  6. Carcinoid tumour of the middle ear

    LENUS (Irish Health Repository)

    Baig, Salman

    2012-09-01

    A case of middle ear mass in a young female from Ireland is described, who presented with left ear hearing loss and intermittent bloody discharge from the same ear. Examination under microscope revealed occlusive polyp in the left ear and a biopsy had been taken under general anaesthesia. Histopathology report described an adenoma \\/ carcinoid tumour of the middle ear confirmed by positive immunohistochemical staining. CT temporal bones revealed the extension of the disease. The patient underwent left tympanotomy and excision of the tumour. In general, these tumours are regarded as benign but may be mistaken for adenocarcinomas because of their histological heterogenecity.

  7. Servo-controlled hind-limb electrical stimulation for short-term arterial pressure control.

    Science.gov (United States)

    Kawada, Toru; Shimizu, Shuji; Yamamoto, Hiromi; Shishido, Toshiaki; Kamiya, Atsunori; Miyamoto, Tadayoshi; Sunagawa, Kenji; Sugimachi, Masaru

    2009-05-01

    Autonomic neural intervention is a promising tool for modulating the circulatory system thereby treating some cardiovascular diseases. In 8 pentobarbital-anesthetized cats, it was examined whether the arterial pressure (AP) could be controlled by acupuncture-like hind-limb electrical stimulation (HES). With a 0.5-ms pulse width, HES monotonically reduced AP as the stimulus current increased from 1 to 5 mA, suggesting that the stimulus current could be a primary control variable. In contrast, the depressor effect of HES showed a nadir approximately 10 Hz in the frequency range between 1 and 100 Hz. Dynamic characteristics of the AP response to HES approximated a second-order low-pass filter with dead time (gain: -10.2 +/- 1.6 mmHg/mA, natural frequency: 0.040 +/- 0.004 Hz, damping ratio 1.80 +/- 0.24, dead time: 1.38 +/- 0.13 s, mean +/- SE). Based on these dynamic characteristics, a servo-controlled HES system was developed. When a target AP value was set at 20 mmHg below the baseline AP, the time required for the AP response to reach 90% of the target level was 38 +/- 10 s. The steady-state error between the measured and target AP values was 1.3 +/- 0.1 mmHg. Autonomic neural intervention by acupuncture-like HES might provide an additional modality to quantitatively control the circulatory system.

  8. Multi-bottle, no compressor, mean pressure control system for a Stirling engine

    Science.gov (United States)

    Corey, John A.

    1990-01-01

    The invention relates to an apparatus for mean pressure control of a Stirling engine without the need for a compressor. The invention includes a multi-tank system in which there is at least one high pressure level tank and one low pressure level tank wherein gas flows through a maximum pressure and supply line from the engine to the high pressure tank when a first valve is opened until the maximum pressure of the engine drops below that of the high pressure tank opening an inlet regulator to permit gas flow from the engine to the low pressure tank. When gas flows toward the engine it flows through the minimum pressure supply line 2 when a second valve is opened from the low pressure tank until the tank reaches the engine's minimum pressure level at which time the outlet regulator opens permitting gas to be supplied from the high pressure tank to the engine. Check valves between the two tanks prevent any backflow of gas from occurring.

  9. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    Science.gov (United States)

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  10. Pressure control for minimizing leakage in water distribution systems

    OpenAIRE

    Nourhan Samir; Rawya Kansoh; Walid Elbarki; Amr Fleifle

    2017-01-01

    In the last decades water resources availability has been a major issue on the international agenda. In a situation of worsening scarcity of water resources and the rapidly increasing of water demands, the state of water losses management is part of manâs survival on earth. Leakage in water supply networks makes up a significant amount, sometimes more than 70% of the total water losses. The best practices suggest that pressure management is one of the most effective way to reduce the amount o...

  11. Water-vapor pressure control in a volume

    Science.gov (United States)

    Scialdone, J. J.

    1978-01-01

    The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

  12. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    International Nuclear Information System (INIS)

    Kitchen, M J; Habib, A; Lewis, R A; Fouras, A; Dubsky, S; Wallace, M J; Hooper, S B

    2010-01-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  13. Development of a PID-Fuzzy controller in the water level control of a pressurizer of a nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Thiago S.P.; Lira, Carlos A.B.O.; Vasconcelos, Wagner E., E-mail: thiago.brito86@yahoo.com.br, E-mail: cabol@ufpe.br, E-mail: wagner@unicap.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Centro de Tecnologia e Geociencias. Departamento de Energia Nuclear; Universidade Catolica de Pernambuco (UNICAP), Recife, PE (Brazil). Centro de Ciencias e Tecnologia

    2017-11-01

    It is well known that safety in the operation of nuclear power plants is a primary requirement because a failure of this system can result in serious problems to the environment. A nuclear reactor has several systems that help keep it in normal operation, within safety margins. Many of these systems operate in the control of variable quantities in the primary circuit of a reactor. However, nuclear reactors are nonlinear physical systems, and this introduces a complexity in the control strategies. Among several mechanisms in the thermal-hydraulic system of a reactor that actuate as a controller, the pressurizer is the component responsible for absorbing pressure variations that occur in the primary circuit. This work aims at the development of a PID controller (Proportional Integral Derivative) based on fuzzy logic to operate in a pressurizer of a nuclear Pressurized Water Reactor. A Fuzzy Controller was developed using the process of fuzzification, inference, and defuzzification of the variables of interest to a pressurizer, then this controller was coupled to a PID Controller building a PID Controller, but oriented by Fuzzy logic. Subsequently, the PID-Fuzzy Controller was experimentally validated in a Simulation Plant in which transients like those in a PWR were conducted. The PID parameters were analyzed and adjusted for better responses and results. The results of the validation were also compared to simple controllers (on / off). (author)

  14. Development of a PID-Fuzzy controller in the water level control of a pressurizer of a nuclear reactor

    International Nuclear Information System (INIS)

    Brito, Thiago S.P.; Lira, Carlos A.B.O.; Vasconcelos, Wagner E.; Universidade Catolica de Pernambuco

    2017-01-01

    It is well known that safety in the operation of nuclear power plants is a primary requirement because a failure of this system can result in serious problems to the environment. A nuclear reactor has several systems that help keep it in normal operation, within safety margins. Many of these systems operate in the control of variable quantities in the primary circuit of a reactor. However, nuclear reactors are nonlinear physical systems, and this introduces a complexity in the control strategies. Among several mechanisms in the thermal-hydraulic system of a reactor that actuate as a controller, the pressurizer is the component responsible for absorbing pressure variations that occur in the primary circuit. This work aims at the development of a PID controller (Proportional Integral Derivative) based on fuzzy logic to operate in a pressurizer of a nuclear Pressurized Water Reactor. A Fuzzy Controller was developed using the process of fuzzification, inference, and defuzzification of the variables of interest to a pressurizer, then this controller was coupled to a PID Controller building a PID Controller, but oriented by Fuzzy logic. Subsequently, the PID-Fuzzy Controller was experimentally validated in a Simulation Plant in which transients like those in a PWR were conducted. The PID parameters were analyzed and adjusted for better responses and results. The results of the validation were also compared to simple controllers (on / off). (author)

  15. Gray mode control or a device with added manoeuvrability: a new fine control system for pressurized water reactors

    International Nuclear Information System (INIS)

    Guilmin, J.

    1983-01-01

    The present fine control system for pressurized water reactors (the so-called ''A'' mode) cannot meet the requirements of a variable output in all respects. For this reason specialists are now developing a new fine control system, called gray mode control which is better suited to rapid load variations. The basic principles for control of pressurized water reactors are summarized and, then gray mode control or the device with added manoeuvrability is described. The series of tests carried out in 1981 and 1982 on stage 3 of the Tricastin power station are analyzed and the satisfactory results obtained are presented [fr

  16. Innovative Control concepts for German pressurized water reactors

    International Nuclear Information System (INIS)

    Brzozowski, Raphael; Kuhn, Andreas

    2010-01-01

    Controlling reactor power without any manual support is becoming more and more important. The READIG project (READIG = Reactor Instrumentation and Digital Control) power control system installed in unit 2 of the Philippsburg nuclear power station (KKP 2) requires no manual intervention except for specific strategy criteria settings. It was even possible to eliminate the power distribution set points. With minor adaptations, this concept can be applied in other PWR plants as well. KKP 2 is a PWR plant with particularly sophisticated core charges; as a consequence, the I and C systems were adapted accordingly. The increase in integral reactor power and the low-leakage core charges are the main reasons for lower limiting margins, especially in peak limiting. The standard control concept was supplemented in such a way that a more precise fine control concept for power distribution in the full-load regime is achieved. The READIG project fully utilizes the possibilities offered by digital TXS Technology, which is why use is also made of physical parameterization. The new power distribution control concept has these advantages: - Operation at small peak-/DNB-reactor output limitation margins. - Stable control without manual intervention also in load cycles and in the frequency control mode. - Simplified operation due to omission of the power distribution set point. - Reduction to zero of the frequency of L-bank steps at constant power with superimposed frequency control mode. - Reduction to zero of the frequency of D-bank steps at constant power with superimposed frequency control mode. - Lower quantities of demineralized water to be fed at constant power with superimposed frequency control mode (±1%). (orig.)

  17. Inner-ear circulation in humans is disrupted by extracranial venous outflow strictures: Implications for Ménière’s disease

    Directory of Open Access Journals (Sweden)

    Eleuterio F. Toro

    2018-02-01

    Full Text Available Ménière’s disease (MD is a pathology of the inner ear, the symptoms of which include tinnitus, vertigo attacks, fluctuating hearing loss, and nausea. Neither cause nor cure are currently known, though animal experiments suggest that disruption of the inner ear circulation, including venous hypertension and endolymphatic hydrops, to be hallmarks of the disease. Recent evidence for humans suggests a potential link to strictures in the extracranial venous outflow routes. The purpose of the present work is to demonstrate that the inner-ear circulation in humans is disrupted by extracranial venous outflow stricture and to discuss the implications of this finding for MD. The hypothesis linking extracranial venous outflow strictures to the altered dynamics of central nervous system (CNS fluid compartments is investigated theoretically via a global, closed-loop, multiscale mathematical model for the entire human circulation, interacting with the brain parenchyma and cerebrospinal fluid (CSF. The fluid dynamics model for the full human body includes submodels for the heart, pulmonary circulation, arterial system, microvasculature, venous system and the CSF, with a specially refined description of the inner ear vasculature. We demonstrate that extracranial venous outflow strictures disrupt inner ear circulation, and more generally, alter the dynamics of fluid compartments in the whole CNS. Specifically, as compared to a healthy control, the computational results from our model show that subjects with extracranial outflow venous strictures exhibit: altered inner ear circulation, redirection of flow to collaterals, increased intracranial venous pressure and increased intracranial pressure. Our findings are consistent with recent clinical evidence in humans that links extracranial outflow venous strictures to MD, aid the mechanistic understanding of the underlying features of the disease and lend support to recently proposed biophysically motivated

  18. Auditory Localization Performance with Asymmetric Integrated Eye and Ear Protection

    Science.gov (United States)

    2018-03-01

    Scharine, Morgan Domanico, Ashley N Foots, Kim Fluitt, and Timothy J Mermagen Human Research and Engineering Directorate, ARL Morgan Domanico Oak...prototypes. The AIEEP is a tactical communications and protection system (TCAPS) that also provides eye protection. Participants used a laser pointer...Decibels “A-weighted” is the sound pressure level adjusted for the sensitivity of the average human ear. The reference level is the

  19. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    Science.gov (United States)

    Groen, Maarten S.; Wu, Kai; Brookhuis, Robert A.; van Houwelingen, Marc J.; Brouwer, Dannis M.; Lötters, Joost C.; Wiegerink, Remco J.

    2014-12-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch.

  20. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    International Nuclear Information System (INIS)

    Groen, Maarten S; Wu, Kai; Brookhuis, Robert A; Lötters, Joost C; Wiegerink, Remco J; Van Houwelingen, Marc J; Brouwer, Dannis M

    2014-01-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch. (paper)

  1. PSO-RBF Neural Network PID Control Algorithm of Electric Gas Pressure Regulator

    Directory of Open Access Journals (Sweden)

    Yuanchang Zhong

    2014-01-01

    Full Text Available The current electric gas pressure regulator often adopts the conventional PID control algorithm to take drive control of the core part (micromotor of electric gas pressure regulator. In order to further improve tracking performance and to shorten response time, this paper presents an improved PID intelligent control algorithm which applies to the electric gas pressure regulator. The algorithm uses the improved RBF neural network based on PSO algorithm to make online adjustment on PID parameters. Theoretical analysis and simulation result show that the algorithm shortens the step response time and improves tracking performance.

  2. Experimental study of the pressure discharge process for the hydraulic control rod drive system stepped cylinder

    International Nuclear Information System (INIS)

    Wang, Jinhua; Bo, Hanliang; Zheng, Wenxiang

    2002-01-01

    The pressure discharge process from the stepped cylinder of the Hydraulic Control Rod Drive System (HCRDS) was studied experimentally in the HCRDS experimental loop for the 200 MW Nuclear Heating Reactor (NHR-200). The results showed that the differential pressure between the outside and the inside of the stepped cylinder increased rapidly to the desired value so that the force induced by the differential pressure which pushes the out tube of stepped cylinder was large enough. Therefore, if the hydraulic control rod were jammed, the pressure could push the hydraulic control rod to overcome the frictional resistance to insert the control rod into the reactor core. The experimental results verified that this design would solve the problem of hydraulic control rod jamming during an accident. (author)

  3. A switched energy saving position controller for variable-pressure electro-hydraulic servo systems.

    Science.gov (United States)

    Tivay, Ali; Zareinejad, Mohammad; Rezaei, S Mehdi; Baghestan, Keivan

    2014-07-01

    The electro-hydraulic servo system (EHSS) demonstrates a relatively low level of efficiency compared to other available actuation methods. The objective of this paper is to increase this efficiency by introducing a variable supply pressure into the system and controlling this pressure during the task of position tracking. For this purpose, an EHSS structure with controllable supply pressure is proposed and its dynamic model is derived from the basic laws of physics. A switching control structure is then proposed to control both the supply pressure and the cylinder position at the same time, in a way that reduces the overall energy consumption of the system. The stability of the proposed switching control system is guaranteed by proof, and its performance is verified by experimental testing. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  4. An assessment of individualized technical ear training for audio production.

    Science.gov (United States)

    Kim, Sungyoung

    2015-07-01

    An individualized technical ear training method is compared to a non-individualized method. The efficacy of the individualized method is assessed using a standardized test conducted before and after the training period. Participants who received individualized training improved better than the control group on the test. Results indicate the importance of individualized training for acquisition of spectrum-identification and spectrum-matching skills. Individualized training, therefore, should be implemented by default into technical ear training programs used in audio production industry and education.

  5. Imaging of the inner ear

    International Nuclear Information System (INIS)

    Casselman, J.W.; Bensimon, J.L.

    1997-01-01

    New computed tomography (CT) and magnetic resonance (MR) techniques allow more detailed anatomic studies of the inner ear. CT is still the best technique to study patients with fractures, congenital malformations and otodystrophies involving the inner ear. During recent years MR imaging has emerged as an excellent method to detect pathology in the internal auditory canal, membranous labyrinth and bony labyrinth and to characterize petrous apex lesions. MR has even proved its value in patients with fractures and congenital malformations making the diagnosis of, for instance, labyrinthine concussion and absence of the vestibulocochlear nerve possible. The diagnosis of acute/chronic labyrinthitis and intralabyrinthine tumors has also became possible. However, MR and CT are often complementary, as is the case in patients with mixed hearing loss, congenital malformations and petrous apex lesions. (orig.) [de

  6. Insights into inner ear-specific gene regulation: epigenetics and non-coding RNAs in inner ear development and regeneration

    Science.gov (United States)

    Avraham, Karen B.

    2016-01-01

    The vertebrate inner ear houses highly specialized sensory organs, tuned to detect and encode sound, head motion and gravity. Gene expression programs under the control of transcription factors orchestrate the formation and specialization of the non-sensory inner ear labyrinth and its sensory constituents. More recently, epigenetic factors and non-coding RNAs emerged as an additional layer of gene regulation, both in inner ear development and disease. In this review, we provide an overview on how epigenetic modifications and non-coding RNAs, in particular microRNAs (miRNAs), influence gene expression and summarize recent discoveries that highlight their critical role in the proper formation of the inner ear labyrinth and its sensory organs. In contrast to non-mammalian vertebrates, adult mammals lack the ability to regenerate inner ear mechano-sensory hair cells. Finally, we discuss recent insights into how epigenetic factors and miRNAs may facilitate, or in the case of mammals, restrict sensory hair cell regeneration. PMID:27836639

  7. Robustness of parameter-less remote real-time pressure control in water distribution systems

    CSIR Research Space (South Africa)

    Page, Philip R

    2017-06-01

    Full Text Available One way of reducing water leakage, pipe bursts and water consumption in a water distribution system (WDS) is to manage the pressure to be as low as possible. This can be done by adjusting a pressure control valve (PCV) in real-time in order to keep...

  8. ABPM vs office blood pressure to define blood pressure control in treated hypertensive paediatric renal transplant recipients.

    Science.gov (United States)

    Ferraris, Jorge R; Ghezzi, Lidia; Waisman, Gabriel; Krmar, Rafael T

    2007-02-01

    While 24-h ambulatory blood pressure monitoring (ABPM) is an established tool for monitoring antihypertensive therapy in adults, data in children are scarce. We retrospectively analysed whether office blood pressure (BP) is reliable for the diagnosis of BP control in 26 treated hypertensive paediatric renal transplants. Controlled office BP was defined as the mean of three replicate systolic and diastolic BP recordings less than or equal to the 95th age-, sex- and height-matched percentile on the three-outpatient visits closest to ABPM. Controlled ABPM was defined as systolic and diastolic daytime BP ABPM reference. Eight recipients (30%) with controlled office BP were in fact categorized as having non-controlled BP by ABPM criteria. Overall, when office BP and ABPM were compared using the Bland and Altman method, the 95% limits of agreement between office and daytime values ranged from -12.6 to 34.1 mmHg for systolic and -23.9 to 31.7 mmHg for diastolic BP, and the mean difference was 10.7 and 3.9 mmHg respectively. Office readings miss a substantial number of recipients who are hypertensive by ABPM criteria. Undertreatment of hypertension could be avoided if ABPM is applied as an adjunct to office readings.

  9. Acid digestion and pressurization control in combustible radwaste treatment

    International Nuclear Information System (INIS)

    Allen, C.R.; Cowan, R.G.; Grelecki, C.J.

    1978-01-01

    Acid digestion has been developed to reduce the volume of combustible nuclear waste materials, while converting them to an inert, noncombustible residue. A 100 kg/day test unit has recently been constructed to process radioactively contaminated combustible wastes. The unit, called the Radioactive Acid Digestion Test Unit (RADTU) was completed in September, 1977, and is currently undergoing nonradioactive shakedown tests. Radioactive operation is expected in May, 1978. Because of uncertainties in waste composition and reactivity, the system was required to contain pressurizations. This led to the development of a simple and inexpensive system, which is capable of attenuating a shock wave from a full scale vapor detonation. The system has potential application in a wide spectrum of chemical reactors, since the fabrication materials are resistant to a very wide range of corrosive chemical attack

  10. An Appraisal of Hospital Based Blood Pressure Control in Port ...

    African Journals Online (AJOL)

    Alasia Datonye

    Department of Internal Medicine, College of Health Sciences, University of Port Harcourt,. Port Harcourt ... The assessment of hypertension control and evaluation of the impact of poor ..... An updated coronary risk profile: A statement from.

  11. Tidal ventilation distribution during pressure-controlled ventilation and pressure support ventilation in post-cardiac surgery patients.

    Science.gov (United States)

    Blankman, P; VAN DER Kreeft, S M; Gommers, D

    2014-09-01

    Inhomogeneous ventilation is an important contributor to ventilator-induced lung injury. Therefore, this study examines homogeneity of lung ventilation by means of electrical impedance tomography (EIT) measurements during pressure-controlled ventilation (PCV) and pressure support ventilation (PSV) using the same ventilation pressures. Twenty mechanically ventilated patients were studied after cardiac surgery. On arrival at the intensive care unit, ventilation distribution was measured with EIT just above the diaphragm for 15 min. After awakening, PCV was switched to PSV and EIT measurements were again recorded. Tidal impedance variation, a measure of tidal volume, increased during PSV compared with PCV, despite using the same ventilation pressures (P = 0.045). The distribution of tidal ventilation to the dependent lung region was more pronounced during PSV compared with PCV, especially during the first half of the inspiration. An even distribution of tidal ventilation between the dependent and non-dependent lung regions was seen during PCV at lower tidal volumes (tidal volumes (≥ 8 ml/kg). In addition, the distribution of tidal ventilation was predominantly distributed to the dependent lung during PSV at low tidal volumes. In post-cardiac surgery patients, PSV showed improved ventilation of the dependent lung region due to the contribution of the diaphragm activity, which is even more pronounced during lower assist levels. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Middle ear function in sinonasal polyposis.

    Science.gov (United States)

    Bakhshaee, Mehdi; Ardakani, Hossein Payedar; Ghazizadeh, Amir Hossain; Movahed, Rahman; Jarahi, Lida; Rajati, Mohsen

    2016-10-01

    Nasal airway patency has long been considered a major factor in ear health. The aim of this study was to determine the effect of sinonasal polyposis on middle ear and eustachian tube (ET) functionality. Forty-four individuals with polyposis, 23 with non-polyposis nasal obstruction, and 23 healthy controls were enrolled. Demographic, clinical and imaging data of all participants were collected and ET function tests and audiologic tests were performed. Hearing loss (p = 0.02), flat tympanogram (p = 0.02), disturbed Toynbee and Valsalva tests (p = 0.01), and the prevalence of allergy (p = 0.04) and purulent nasal discharge (p polyposis group than the other groups. Regression analysis revealed that infection and allergy have more important roles in ET function than the nasal obstruction. Polyposis could impede ET function; however, it is probably not because of its obstructive nature, but because of the associated increased risk of infection.

  13. Hydrostatic fluid pressure in the vestibular organ of the guinea pig.

    Science.gov (United States)

    Park, Jonas J-H; Boeven, Jahn J; Vogel, Stefan; Leonhardt, Steffen; Wit, Hero P; Westhofen, Martin

    2012-07-01

    Since inner ear hair cells are mechano-electric transducers the control of hydrostatic pressure in the inner ear is crucial. Most studies analyzing dynamics and regulation of inner ear hydrostatic pressure performed pressure measurements in the cochlea. The present study is the first one reporting about absolute hydrostatic pressure values in the labyrinth. Hydrostatic pressure of the endolymphatic system was recorded in all three semicircular canals. Mean pressure values were 4.06 cmH(2)O ± 0.61 in the posterior, 3.36 cmH(2)O ± 0.94 in the anterior and 3.85 cmH(2)O ± 1.38 in the lateral semicircular canal. Overall hydrostatic pressure in the vestibular organ was 3.76 cmH(2)O ± 0.36. Endolymphatic hydrostatic pressure in all three semicircular canals is the same (p = 0.310). With regard to known endolymphatic pressure values in the cochlea from past studies vestibular pressure values are comparable to cochlear values. Until now it is not known whether the reuniens duct and the Bast's valve which are the narrowest passages in the endolymphatic system are open or closed. Present data show that most likely the endolymphatic system is a functionally open entity.

  14. Awareness of high blood pressure status, treatment and control in a ...

    African Journals Online (AJOL)

    west LGA of Edo State to assess the level of awareness of high blood pressure status, treatment and control. Cluster sampling method was used to select participants and data collection was by researcher administered questionnaire. Blood ...

  15. Analysis of an controller design for an electro-hydraulic servo pressure regulator

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Madsen, A. M.

    2009-01-01

    Mobile hydraulics is in a transition phase, where electronic sensors and digital signal processors are starting to become standard on a high number of machines, hereby replacing hydraulic pilot lines and oering new possibilities with regard to both control and feasibility. For controlling some...... of the existing hydraulic components there are, however, still a need for being able to generate a hydraulic pilot pressure, as e.g. almost all open-circuit pumps are hydraulically controlled. The focus of the current paper is therefore on the analysis and controller design an electro-hydraulic servo pressure...... regulator, which generates a hydraulic LS-pressure based on an electrical reference, hereby synergistically integrating knowledge from all parts of the mechatronics area. The servo pressure regulator is used to generate the LS-signal for a variable displacement pump, and the paper rst presents...

  16. Experimental research on charging characteristics of a solar photovoltaic system by the pressure-control method

    Institute of Scientific and Technical Information of China (English)

    Hua ZHU; Zhang-lu XU; Zi-juan CAO

    2011-01-01

    The charging characteristics of the valve-regulated lead acid (VRLA) battery driven by solar energy were experimentally studied through the pressure-control method in this paper. The aims of the research were to increase charging efficiency to make the most of solar energy and to improve charging quality to prolong life of battery. The charging process of a 12 V 12 A.h VRLA battery has been tested under the mode of a stand-alone photovoltaic (PV) system. Results show that the pressure-control method can effectively control PV charging of the VRLA battery and make the best of PV cells through the maximum power point tracking (MPPT). The damage of VRLA battery by excess oxygen accumulation can be avoided through the inner pressure control of VRLA battery. Parameters such as solar radiation intensity, charging power, inner pressure of the battery, and charging current and voltage during the charging process were measured and analyzed.

  17. Intensive Blood Pressure Control Affects Cerebral Blood Flow in Type 2 Diabetes Mellitus Patients

    NARCIS (Netherlands)

    Kim, Yu-Sok; Davis, Shyrin C. A. T.; Truijen, Jasper; Stok, Wim J.; Secher, Niels H.; van Lieshout, Johannes J.

    2011-01-01

    Type 2 diabetes mellitus is associated with microvascular complications, hypertension, and impaired dynamic cerebral autoregulation. Intensive blood pressure (BP) control in hypertensive type 2 diabetic patients reduces their risk of stroke but may affect cerebral perfusion. Systemic hemodynamic

  18. Possibilities of obtaining and controlling high-quality pressure castings

    Directory of Open Access Journals (Sweden)

    S. Pietrowski

    2011-07-01

    Full Text Available The paper presents the influence of the type of furnace charging melting, refining and modification silumins 226 and 231 on the porosity and microstructure of castings. It was shown that in order to reduce or eliminate the porosity of the castings is necessary to the refining ECOSAL-AL113 of liquid silumin both in the melting furnace, and in the ladle and an additional nitrogen, in the heat furnace modified and refining with nitrogen. To control the effects of refining and modifying the TDA method was used. It was found that based on crystal- lization curve can be qualitatively assess the gas porosity of the castings. In order to control and quality control silumins author developed a computer program using the method of TDA, which sets out: Rm, A5, HB and casting porosity P and the concentration of hydrogen in them. The program also informs the technological procedures to be performed for liquid silumin improper preparation.

  19. Socioeconomic and modifiable predictors of blood pressure control ...

    African Journals Online (AJOL)

    Background. Low socioeconomic status is associated with the risk of hypertension. There are few reports of the effect of socioeconomic and potentially modifiable factors on the control of hypertension in South Africa (SA). Objectives. To investigate associations between patients' socioeconomic status and characteristics of ...

  20. Two sides of a fault: Grain-scale analysis of pore pressure control on fault slip

    Science.gov (United States)

    Yang, Zhibing; Juanes, Ruben

    2018-02-01

    Pore fluid pressure in a fault zone can be altered by natural processes (e.g., mineral dehydration and thermal pressurization) and industrial operations involving subsurface fluid injection and extraction for the development of energy and water resources. However, the effect of pore pressure change on the stability and slip motion of a preexisting geologic fault remains poorly understood; yet, it is critical for the assessment of seismic hazard. Here, we develop a micromechanical model to investigate the effect of pore pressure on fault slip behavior. The model couples fluid flow on the network of pores with mechanical deformation of the skeleton of solid grains. Pore fluid exerts pressure force onto the grains, the motion of which is solved using the discrete element method. We conceptualize the fault zone as a gouge layer sandwiched between two blocks. We study fault stability in the presence of a pressure discontinuity across the gouge layer and compare it with the case of continuous (homogeneous) pore pressure. We focus on the onset of shear failure in the gouge layer and reproduce conditions where the failure plane is parallel to the fault. We show that when the pressure is discontinuous across the fault, the onset of slip occurs on the side with the higher pore pressure, and that this onset is controlled by the maximum pressure on both sides of the fault. The results shed new light on the use of the effective stress principle and the Coulomb failure criterion in evaluating the stability of a complex fault zone.

  1. Two sides of a fault: Grain-scale analysis of pore pressure control on fault slip.

    Science.gov (United States)

    Yang, Zhibing; Juanes, Ruben

    2018-02-01

    Pore fluid pressure in a fault zone can be altered by natural processes (e.g., mineral dehydration and thermal pressurization) and industrial operations involving subsurface fluid injection and extraction for the development of energy and water resources. However, the effect of pore pressure change on the stability and slip motion of a preexisting geologic fault remains poorly understood; yet, it is critical for the assessment of seismic hazard. Here, we develop a micromechanical model to investigate the effect of pore pressure on fault slip behavior. The model couples fluid flow on the network of pores with mechanical deformation of the skeleton of solid grains. Pore fluid exerts pressure force onto the grains, the motion of which is solved using the discrete element method. We conceptualize the fault zone as a gouge layer sandwiched between two blocks. We study fault stability in the presence of a pressure discontinuity across the gouge layer and compare it with the case of continuous (homogeneous) pore pressure. We focus on the onset of shear failure in the gouge layer and reproduce conditions where the failure plane is parallel to the fault. We show that when the pressure is discontinuous across the fault, the onset of slip occurs on the side with the higher pore pressure, and that this onset is controlled by the maximum pressure on both sides of the fault. The results shed new light on the use of the effective stress principle and the Coulomb failure criterion in evaluating the stability of a complex fault zone.

  2. Prevention and control of high blood pressure: challenges and opportunities.

    OpenAIRE

    Campbell, N R; Chockalingam, A

    1995-01-01

    Cardiovascular disease is still the leading cause of death in developed countries and is becoming more common in the developing world. The reduction in incidence of many cardiovascular diseases in the last few decades may be attributed in part to extensive programs to reduce and manage risk factors such as hypertension. Nevertheless, untreated, uncontrolled and undiagnosed hypertension remains a significant concern. Many nations have adopted policies and programs for hypertension control. An ...

  3. Rankine cycle condenser pressure control using an energy conversion device bypass valve

    Science.gov (United States)

    Ernst, Timothy C; Nelson, Christopher R; Zigan, James A

    2014-04-01

    The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.

  4. EFFECT OF POWER SUPPLY AND DUTY CONTROL IN CRANKCASE FLOW (CRANKCASE PRESSURE PORT OF ECV

    Directory of Open Access Journals (Sweden)

    MD. IQBAL MAHMUD

    2016-06-01

    Full Text Available The electromagnetic control valve (ECV operated by solenoid in the external variable compressor with the swash plate type is the rising phenomenon. ECV controls the air conditioning compressor for automobile on the basis of the input signal of the pulse width modulation (PWM that supplied from the external controller. PWM technique is used to encode the information for transmission; its main use is to allow the control of the power to be supplied to electrical devices, especially to inertial loads. The mechanism changes the swash plate angle inside the compressor by increasing or reducing the pressure of swash plate chamber by use of the functions of different pressure port within the ECV. Increasing and reducing the swash plate angle finally depends on the solenoid force acting on the rate of supply of current. This research paper investigates the effect of power supply and duty control during the crankcase flowing at Pc pressure port of ECV.

  5. The CHIPS Randomized Controlled Trial (Control of Hypertension in Pregnancy Study): Is Severe Hypertension Just an Elevated Blood Pressure?

    NARCIS (Netherlands)

    Magee, Laura A.; von Dadelszen, Peter; Singer, Joel; Lee, Terry; Rey, Evelyne; Ross, Susan; Asztalos, Elizabeth; Murphy, Kellie E.; Menzies, Jennifer; Sanchez, Johanna; Gafni, Amiram; Helewa, Michael; Hutton, Eileen; Koren, Gideon; Lee, Shoo K.; Logan, Alexander G.; Ganzevoort, Wessel; Welch, Ross; Thornton, Jim G.; Moutquin, Jean-Marie

    2016-01-01

    To determine whether clinical outcomes differed by occurrence of severe hypertension in the international CHIPS trial (Control of Hypertension in Pregnancy Study), adjusting for the interventions of less tight (target diastolic blood pressure [dBP] 100 mmHg) versus tight control (target dBP 85

  6. Characteristics of laser-induced shock wave injury to the inner ear of rats

    Science.gov (United States)

    Kurioka, Takaomi; Matsunobu, Takeshi; Niwa, Katsuki; Tamura, Atsushi; Kawauchi, Satoko; Satoh, Yasushi; Sato, Shunichi; Shiotani, Akihiro

    2014-12-01

    Recently, the number of blast injuries of the inner ear has increased in the general population. In blast-induced inner ear injury, a shock wave (SW) component in the blast wave is considered to play an important role in sensorineural hearing loss. However, the mechanisms by which an SW affects inner ear tissue remain largely unknown. We aimed to establish a new animal model for SW-induced inner ear injury by using laser-induced SWs (LISWs) on rats. The LISWs were generated by irradiating an elastic laser target with 694-nm nanosecond pulses of a ruby laser. After LISW application to the cochlea through bone conduction, auditory measurements revealed the presence of inner ear dysfunction, the extent of which depended on LISW overpressure. A significantly lower survival rate of hair cells and spiral ganglion neurons, as well as severe oxidative damage, were observed in the inner ear exposed to an LISW. Although considerable differences in the pressure characteristics exist between LISWs and SWs in real blast waves, the functional and morphological changes shown by the present LISW-based model were similar to those observed in real blast-induced injury. Thus, our animal model is expected to be useful for laboratory-based research of blast-induced inner ear injury.

  7. Characteristics of laser-induced shock wave injury to the inner ear of rats.

    Science.gov (United States)

    Kurioka, Takaomi; Matsunobu, Takeshi; Niwa, Katsuki; Tamura, Atsushi; Kawauchi, Satoko; Satoh, Yasushi; Sato, Shunichi; Shiotani, Akihiro

    2014-12-01

    Recently, the number of blast injuries of the inner ear has increased in the general population. In blast-induced inner ear injury, a shock wave (SW) component in the blast wave is considered to play an important role in sensorineural hearing loss. However, the mechanisms by which an SW affects inner ear tissue remain largely unknown. We aimed to establish a new animal model for SW-induced inner ear injury by using laser-induced SWs (LISWs) on rats. The LISWs were generated by irradiating an elastic laser target with 694-nm nanosecond pulses of a ruby laser. After LISW application to the cochlea through bone conduction, auditory measurements revealed the presence of inner ear dysfunction, the extent of which depended on LISW overpressure. A significantly lower survival rate of hair cells and spiral ganglion neurons, as well as severe oxidative damage, were observed in the inner ear exposed to an LISW. Although considerable differences in the pressure characteristics exist between LISWs and SWs in real blast waves, the functional and morphological changes shown by the present LISW-based model were similar to those observed in real blast-induced injury. Thus, our animal model is expected to be useful for laboratory-based research of blast-induced inner ear injury.

  8. Ear-body lift and a novel thrust generating mechanism revealed by the complex wake of brown long-eared bats (Plecotus auritus)

    Science.gov (United States)

    Johansson, L. Christoffer; Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders

    2016-04-01

    Large ears enhance perception of echolocation and prey generated sounds in bats. However, external ears likely impair aerodynamic performance of bats compared to birds. But large ears may generate lift on their own, mitigating the negative effects. We studied flying brown long-eared bats, using high resolution, time resolved particle image velocimetry, to determine the aerodynamics of flying with large ears. We show that the ears and body generate lift at medium to cruising speeds (3-5 m/s), but at the cost of an interaction with the wing root vortices, likely reducing inner wing performance. We also propose that the bats use a novel wing pitch mechanism at the end of the upstroke generating thrust at low speeds, which should provide effective pitch and yaw control. In addition, the wing tip vortices show a distinct spiraling pattern. The tip vortex of the previous wingbeat remains into the next wingbeat and rotates together with a newly formed tip vortex. Several smaller vortices, related to changes in circulation around the wing also spiral the tip vortex. Our results thus show a new level of complexity in bat wakes and suggest large eared bats are less aerodynamically limited than previous wake studies have suggested.

  9. An Effective 3D Ear Acquisition System.

    Directory of Open Access Journals (Sweden)

    Yahui Liu

    Full Text Available The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  10. Application of a neural network to control a pressurized water reactor

    International Nuclear Information System (INIS)

    Lin, C.; Ku, C.C.; Lee, C.S.

    1993-01-01

    A neural network has been trained to control a pressurized water reactor. The inputs of the training pattern are the plant signals, and the outputs are the control rod actions. The training patterns are some kind of lookup table of control action. The table is designed by the heuristic method, which is based on the designer's knowledge of the controlled system and the operation experience. This method has two advantages: The controller's performance does not depend on the mathematical model of the plant, and the controller could be a nonlinear one. The advantages of using neural networks to implement the controller are to save computing time and overcome partial hardware failure

  11. Effects of wet-cupping on blood pressure in hypertensive patients: a randomized controlled trial.

    Science.gov (United States)

    Aleyeidi, Nouran A; Aseri, Khaled S; Matbouli, Shadia M; Sulaiamani, Albaraa A; Kobeisy, Sumayyah A

    2015-11-01

    Although cupping remains a popular treatment modality worldwide, its efficacy for most diseases, including hypertension, has not been scientifically evaluated. We aimed to determine the efficacy of wet-cupping for high blood pressure, and the incidence of the procedure's side effects in the intervention group. This is a randomized controlled trial conducted in the General Practice Department at King Abdulaziz University Hospital, Jeddah, Saudi Arabia, between May 2013 and February 2014. There were two groups (40 participants each): intervention group undergoing wet-cupping (hijama) in addition to conventional hypertension treatment, and a control group undergoing only conventional hypertension treatment. Three wet-cupping sessions were performed every other day. The mean systolic and diastolic blood pressures were measured using a validated automatic sphygmomanometer. The follow-up period was 8 weeks. Wet-cupping provided an immediate reduction of systolic blood pressure. After 4 weeks of follow-up, the mean systolic blood pressure in the intervention group was 8.4 mmHg less than in the control group (P=0.046). After 8 weeks, there were no significant differences in blood pressures between the intervention and control groups. In this study, wet-cupping did not result in any serious side effects. Wet-cupping therapy is effective for reducing systolic blood pressure in hypertensive patients for up to 4 weeks, without serious side effects. Wet-cupping should be considered as a complementary hypertension treatment, and further studies are needed. ClinicalTrials.gov Identifier NCT01987583.

  12. Design of a new PID controller using predictive functional control optimization for chamber pressure in a coke furnace.

    Science.gov (United States)

    Zhang, Jianming

    2017-03-01

    An improved proportional-integral-derivative (PID) controller based on predictive functional control (PFC) is proposed and tested on the chamber pressure in an industrial coke furnace. The proposed design is motivated by the fact that PID controllers for industrial processes with time delay may not achieve the desired control performance because of the unavoidable model/plant mismatches, while model predictive control (MPC) is suitable for such situations. In this paper, PID control and PFC algorithm are combined to form a new PID controller that has the basic characteristic of PFC algorithm and at the same time, the simple structure of traditional PID controller. The proposed controller was tested in terms of set-point tracking and disturbance rejection, where the obtained results showed that the proposed controller had the better ensemble performance compared with traditional PID controllers. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Experimental Studies of Low-Pressure Turbine Flows and Flow Control. Streamwise Pressure Profiles and Velocity Profiles

    Science.gov (United States)

    Volino, Ralph

    2012-01-01

    This report summarizes research performed in support of the NASA Glenn Research Center (GRC) Low-Pressure Turbine (LPT) Flow Physics Program. The work was performed experimentally at the U.S. Naval Academy faculties. The geometry corresponded to "Pak B" LPT airfoil. The test section simulated LPT flow in a passage. Three experimental studies were performed: (a) Boundary layer measurements for ten baseline cases under high and low freestream turbulence conditions at five Reynolds numbers of 25,000, 50,000, 100,000, 200,000, and 300,000, based on passage exit velocity and suction surface wetted length; (b) Passive flow control studies with three thicknesses of two-dimensional bars, and two heights of three-dimensional circular cylinders with different spanwise separations, at same flow conditions as the 10 baseline cases; (c) Active flow control with oscillating synthetic (zero net mass flow) vortex generator jets, for one case with low freestream turbulence and a low Reynolds number of 25,000. The Passive flow control was successful at controlling the separation problem at low Reynolds numbers, with varying degrees of success from case to case and varying levels of impact at higher Reynolds numbers. The active flow control successfully eliminated the large separation problem for the low Reynolds number case. Very detailed data was acquired using hot-wire anemometry, including single and two velocity components, integral boundary layer quantities, turbulence statistics and spectra, turbulent shear stresses and their spectra, and intermittency, documenting transition, separation and reattachment. Models were constructed to correlate the results. The report includes a summary of the work performed and reprints of the publications describing the various studies.This report summarizes research performed in support of the NASA Glenn Research Center (GRC) Low-Pressure Turbine (LPT) Flow Physics Program. The work was performed experimentally at the U.S. Naval Academy

  14. Socio-economic status influences blood pressure control despite equal access to care

    DEFF Research Database (Denmark)

    Paulsen, M S; Andersen, M; Munck, A P

    2012-01-01

    OBJECTIVE: Denmark has a health care system with free and equal access to care irrespective of age and socio-economic status (SES). We conducted a cross-sectional study to investigate a possible association between SES and blood pressure (BP) control of hypertensive patients treated in general...... Statistics Denmark. The outcome measure was BP control defined as BP...

  15. Clinical evaluation of an automatic blood pressure controller during cardiac surgery

    NARCIS (Netherlands)

    Meijers, R.H.A.M.; Schmartz, D.; Cantraine, F.R.L.; Barvais, L.; d Hollander, A.A.; Blom, J.A.

    1997-01-01

    During surgery, computers can be of great use to support the anesthesiologist in providing task automation. In this paper we describe a closed loop blood pressure controller and show the results of its clinical evalua- tion.Methods. The controller is based on a simple and robust

  16. Why business unit controllers create budget slack: Involvement in management, social pressure, and Machiavellianism

    NARCIS (Netherlands)

    Hartmann, F.G.H.; Maas, V.S.

    2010-01-01

    This paper investigates business unit (BU) controllers’ inclination to engage in the creation of budgetary slack. In particular, we explore whether controllers who are involved in BU decision making are more susceptible to social pressure to engage in slack creation than controllers who are not. We

  17. Pressure intelligent control strategy of Waste heat recovery system of converter vapors

    Science.gov (United States)

    Feng, Xugang; Wu, Zhiwei; Zhang, Jiayan; Qian, Hong

    2013-01-01

    The converter gas evaporative cooling system is mainly used for absorbing heat in the high temperature exhaust gas which produced by the oxygen blowing reaction. Vaporization cooling steam pressure control system of converter is a nonlinear, time-varying, lagging behind, close coupling of multivariable control object. This article based on the analysis of converter operation characteristics of evaporation cooling system, of vaporization in a production run of pipe pressure variation and disturbance factors.For the dynamic characteristics of the controlled objects,we have improved the conventional PID control scheme.In Oxygen blowing process, we make intelligent control by using fuzzy-PID cascade control method and adjusting the Lance,that it can realize the optimization of the boiler steam pressure control.By design simulation, results show that the design has a good control not only ensures drum steam pressure in the context of security, enabling efficient conversion of waste heat.And the converter of 1800 flue gas through pipes and cool and dust removal also can be cooled to about 800. Therefore the converter haze evaporative cooling system has achieved to the converter haze temperature decrease effect and enhanced to the coal gas returns-ratio.

  18. Association of Dermatological Conditions of External Ear with the Use of Cotton Buds

    Directory of Open Access Journals (Sweden)

    Salahuddin Ahmed

    2014-09-01

    Full Text Available Background: The habit of cleaning the external auditory canal with cotton buds is a common practice of the masses. It has strong association with neurodermatitis and contact dermatitis of the external ear. It is also associated with acute otitis externa, rupture of tympanic membrane causing bleeding and temporary hearing loss in some cases. In many cases the injury will heal but damage to minuscule bones deep inside the ear can cause permanent deafness. Objective: The objective of this study was to determine the association of dermatological condition of external ear with the use of cotton buds. Materials and Methods: This case control study was done from January to October 2012 in the Ear Nose Throat Department of Pakistan Level III Hospital, Darfur, Sudan. Sixty seven patients with dermatological diseases of external ear were cases and 83 subjects without dermatological diseases of external ear were selected as controls. Results: Among 67 cases, 58 were cotton bud users and among 83 controls only 29 were cotton bud users. Different types of dermatological diseases were neurodermatitis (34.32%, otitis externa (28.36%, contact dermatitis (26.87% and wax impaction (8.95%. Ninety three percent of cotton bud users were ignorant of harmful effects of this bad habit. Conclusion: There is a strong association of dermatological diseases of external ear with the use of cotton bud which should be discouraged by fortifying the warning by manufacturers and health education at various educational levels.

  19. Solenoid Driven Pressure Valve System: Toward Versatile Fluidic Control in Paper Microfluidics.

    Science.gov (United States)

    Kim, Taehoon H; Hahn, Young Ki; Lee, Jungmin; van Noort, Danny; Kim, Minseok S

    2018-02-20

    As paper-based diagnostics has become predominantly driven by more advanced microfluidic technology, many of the research efforts are still focused on developing reliable and versatile fluidic control devices, apart from improving sensitivity and reproducibility. In this work, we introduce a novel and robust paper fluidic control system enabling versatile fluidic control. The system comprises a linear push-pull solenoid and an Arduino Uno microcontroller. The precisely controlled pressure exerted on the paper stops the flow. We first determined the stroke distance of the solenoid to obtain a constant pressure while examining the fluidic time delay as a function of the pressure. Results showed that strips of grade 1 chromatography paper had superior reproducibility in fluid transport. Next, we characterized the reproducibility of the fluidic velocity which depends on the type and grade of paper used. As such, we were able to control the flow velocity on the paper and also achieve a complete stop of flow with a pressure over 2.0 MPa. Notably, after the actuation of the pressure driven valve (PDV), the previously pressed area regained its original flow properties. This means that, even on a previously pressed area, multiple valve operations can be successfully conducted. To the best of our knowledge, this is the first demonstration of an active and repetitive valve operation in paper microfluidics. As a proof of concept, we have chosen to perform a multistep detection system in the form of an enzyme-linked immunosorbent assay with mouse IgG as the target analyte.

  20. Remote controlled ultrasonic pre-service and in-service inspections of reactor pressure vessels

    International Nuclear Information System (INIS)

    Mueller, G.

    1990-01-01

    The first mechanised in-service inspection of the reactor pressure vessel on unit one of Eskom's Koeberg nuclear power station has been carried out. Since 1968 a whole range of manipulators to carry out remote controlled ultrasonic inspections of nuclear power station equipment has been developed. The inspection of a reactor pressure vessel using a central mast manipulator is described. 3 figs., 1 ill

  1. Heave disturbance attenuation in managed pressure drilling from a floating platform using model predictive control

    OpenAIRE

    Hatlevik, Edvin

    2014-01-01

    Since a large part of the Norwegian oil shelf has been active for over a generation, many fields begin to be depleted and the drilling operations requires tight down hole pressure margins. And by improving the pressure control for the drilling operations former undrillable wells becomes drillable. Which will make the the oilfields more profitable, and extend their life expectancy. It will also make drilling operations safer by preventing kicks and preventing environmental damages caused by mu...

  2. Topical anti-inflammatory activity of Polygonum cuspidatum extract in the TPA model of mouse ear inflammation

    Directory of Open Access Journals (Sweden)

    Wicker Louise

    2008-02-01

    Full Text Available Abstract Background This study tested the ability of a characterized extract of Polygonum cuspidatum (PCE to inhibit mouse ear inflammation in response to topical application of 12-O-tetradecanoylphorbol-13-acetate (TPA. Methods A 50% (wt:vol ethanolic solution of commercial 200:1 PCE was applied to both ears of female Swiss mice (n = 8 at 0.075, 0.15, 0.3, 1.25 and 2.5 mg/ear 30 min after TPA administration (2 μg/ear. For comparison, 3 other groups were treated with TPA and either 1 the vehicle (50% ethanol alone, 2 indomethacin (0.5 mg/ear, or 3 trans-resveratrol (0.62 mg/ear. Ear thickness was measured before TPA and at 4 and 24 h post-TPA administration to assess ear edema. Ear punch biopsies were collected at 24 h and weighed as a second index of edema. Myeloperoxidase activity was measured in each ear punch biopsy to assess neutrophil infiltration. Results PCE treatment at all doses significantly reduced ear edema compared to the TPA control. The PCE response was dose-dependent and 2.5 mg PCE significantly inhibited all markers of inflammation to a greater extent than indomethacin (0.5 mg. MPO activity was inhibited at PCE doses ≥ 1.25 mg/ear. Trans-resveratrol inhibited inflammation at comparable doses. Conclusion PCE inhibits development of edema and neutrophil infiltration in the TPA-treated mouse ear model of topical inflammation.

  3. MicroRNAs in sensorineural diseases of the ear

    Directory of Open Access Journals (Sweden)

    Kathy eUshakov

    2013-12-01

    Full Text Available Non-coding microRNAs have a fundamental role in gene regulation and expression in almost every multicellular organism. Only discovered in the last decade, microRNAs are already known to play a leading role in many aspects of disease. In the vertebrate inner ear, microRNAs are essential for controlling development and survival of hair cells. Moreover, dysregulation of microRNAs has been implicated in sensorineural hearing impairment, as well as in other ear diseases such as cholesteatomas, vestibular schwannomas and otitis media. Due to the inaccessibility of the ear in humans, animal models have provided the optimal tools to study microRNA expression and function, in particular mice and zebrafish. A major focus of current research has been to discover the targets of the microRNAs expressed in the inner ear, in order to determine the regulatory pathways of the auditory and vestibular systems. The potential for microRNA manipulation in development of therapeutic tools for hearing impairment is as yet unexplored, paving the way for future work in the field.

  4. Central venous pressure and mean circulatory filling pressure in the dogfish Squalus acanthias: adrenergic control and role of the pericardium.

    Science.gov (United States)

    Sandblom, Erik; Axelsson, Michael; Farrell, Anthony P

    2006-11-01

    Subambient central venous pressure (Pven) and modulation of venous return through cardiac suction (vis a fronte) characterizes the venous circulation in sharks. Venous capacitance was estimated in the dogfish Squalus acanthias by measuring the mean circulatory filling pressure (MCFP) during transient occlusion of cardiac outflow. We tested the hypothesis that venous return and cardiac preload can be altered additionally through adrenergic changes of venous capacitance. The experiments involved the surgical opening of the pericardium to place a perivascular occluder around the conus arteriosus. Another control group was identically instrumented, but lacked the occluder, and was subjected to the same pharmacological protocol to evaluate how pericardioectomy affected cardiovascular status. Routine Pven was negative (-0.08+/-0.02 kPa) in control fish but positive (0.09+/-0.01 kPa) in the pericardioectomized group. Injections of 5 microg/kg body mass (Mb) of epinephrine and phenylephrine (100 microg/kg Mb) increased Pven and MCFP, whereas isoproterenol (1 microg/kg Mb) decreased both variables. Thus, constriction and relaxation of the venous vasculature were mediated through the respective stimulation of alpha- and beta-adrenergic receptors. Alpha-adrenergic blockade with prazosin (1 mg/kg Mb) attenuated the responses to phenylephrine and decreased resting Pven in pericardioectomized animals. Our results provide convincing evidence for adrenergic control of the venous vasculature in elasmobranchs, although the pericardium is clearly an important component in the modulation of venous function. Thus active changes in venous capacitance have previously been underestimated as an important means of modulating venous return and cardiac performance in this group.

  5. Analysis of fatigue reliability for high temperature and high pressure multi-stage decompression control valve

    Science.gov (United States)

    Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang

    2018-03-01

    Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.

  6. Real-time adjustment of pressure to demand in water distribution systems: Parameter-less P-controller algorithm

    CSIR Research Space (South Africa)

    Page, Philip R

    2016-08-01

    Full Text Available Remote real-time control is currently the most advanced form of pressure management. Here the parameters describing pressure control valves (or pumps) are changed in real-time in such a way to provide the most optimal pressure in the water...

  7. Effects of topical insulin on second-intention wound healing in the red-eared slider turtle (Trachemys scripta elegans) - a controlled study.

    Science.gov (United States)

    Negrini, Joao; Mozos, Elena; Escamilla, Alejandro; Pérez, José; Lucena, Rosario; Guerra, Rafael; Ginel, Pedro J

    2017-06-06

    Compared with mammals, wound healing in reptiles is characterized by reduced wound contraction and longer healing times. The aim of this study is to describe the clinical and histopathological effects of topical insulin on second-intention healing of experimentally induced wounds in skin without dermal bony plates of Trachemys scripta elegans exposed to daily variations in ambient temperature and in an aquatic environment. Forty-four healthy adult females were assigned to two groups: Group 1 (n = 24) was used to assess clinical features such as wound contraction; Group 2 (n = 20) was used for histological evaluation and morphometric analysis. Topical porcine insulin (5 IU/ml diluted in glycerol) was applied daily 1 week. For each control time (2, 7, 14, 21 and 28 days post-wounding), re-epithelisation and wound remodelling were evaluated histologically and the number of main inflammatory cells (heterophils, macrophages, lymphocytes and fibroblasts) was scored. Mean wound contraction was higher in the insulin-treated group at each time point and differences were significant at day 28 (P Trachemys scripta and should be evaluated in non-experimental wounds of turtles and other reptiles.

  8. Objective Audiometry using Ear-EEG

    DEFF Research Database (Denmark)

    Christensen, Christian Bech; Kidmose, Preben

    Recently, a novel electroencephalographic (EEG) method called ear-EEG [1], that enable recording of auditory evoked potentials (AEPs) from a personalized earpiece was introduced. Initial investigations show that well established AEPs, such as ASSR and P1-N1-P2 complex can be observed from ear-EEG...

  9. Congenital malformation of inner ear, single cavity

    International Nuclear Information System (INIS)

    Torres Pazmino, Julio Cesar; Marrugo Pardo, Gilberto Eduardo

    2010-01-01

    Congenital malformations of the inner ear are rare conditions, but their detection requires high diagnostic accuracy. In this report we describe the case of a patient with single or common cavity, discuss the corresponding radiological images, describe the treatment of this patient with a cochlear implant, and review the classification and differential diagnosis of the other anomalies of the inner ear.

  10. Interconnections between the Ears in Nonmammalian Vertebrates

    DEFF Research Database (Denmark)

    Feng, Albert S.; Christensen-Dalsgaard, J.

    2010-01-01

    Many of the nonmammalian vertebrates (anurans, lizards, crocodiles, and some bird species) have large, continuous air spaces connecting the middle ears and acoustically coupling the eardrums. Acoustical coupling leads to strongly enhanced directionality of the ear at frequencies where diffraction...... cues are negligible in small-sized animals. The chapter reviews the peripheral basis of directionality in these animal groups....

  11. Coupled ears in lizards and crocodilians

    DEFF Research Database (Denmark)

    Carr, Catherine E; Christensen-Dalsgaard, Jakob; Bierman, Hilary

    2016-01-01

    Lizard ears are coupled across the pharynx, and are very directional. In consequence all auditory responses should be directional, without a requirement for computation of sound source location. Crocodilian ears are connected through sinuses, and thus less tightly coupled. Coupling may improve th...... range is reviewed in the light of current theories of sound localization....

  12. Well control during the drilling and testing of high pressure offshore wells

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This Code has been prepared for use as a guide to safe practice for those concerned with well control during the drilling and testing of high pressure offshore wells. It is intended to provide information and guidance on those well control activities associated with high pressure wells which have an impact on safety offshore, and therefore require detailed care and attention. The Code has been produced in a United Kingdom Continental Shelf (UKCS) context, but the principles and recommendations have general relevance to similar operations elsewhere. Each chapter of the Code covers an important aspect of well control and has an introduction which describes the part each activity plays in the drilling and testing of high pressure offshore wells. (Author)

  13. LH2 tank pressure control by thermodynamic vent system (TVS) at zero gravity

    Science.gov (United States)

    Wang, B.; Huang, Y. H.; Chen, Z. C.; Wu, J. Y.; Li, P.; Sun, P. J.

    2017-02-01

    Thermodynamic vent system (TVS) is employed for pressure control of propellant tanks at zero gravity. An analytical lumped parameter model is developed to predict pressure variation in an 18.09 m3 liquid hydrogen tank equipped with TVS. Mathematical simulations are carried out assuming tank is filled up to 75% volume (liquid mass equals to 945 kg) and is subjected to heat flux of 0.76 W/m2. Tank pressure controls at 165.5-172.4, 165.5-179.3 and 165.5-182.2 kPa are compared with reference to number of vent cycles, vent duration per cycle and loss of hydrogen. Analysis results indicate that the number of vent cycles significantly decreases from 62 to 21 when tank pressure control increases from 6.9 to 20.4 kPa. Also, duration of vent cycle increases from 63 to 152 and cycle duration decreases from 3920 to 3200 s. Further, the analysis result suggests that LH2 evaporation loss per day decreases from 0.17 to 0.14%. Based on the results of analysis, TVS is found effective in controlling the propellant tank pressure in zero gravity.

  14. Impact of the duct static pressure reset control strategy on the energy consumption by the HVAC system

    Directory of Open Access Journals (Sweden)

    Walaszczyk Juliusz

    2017-01-01

    Full Text Available This article addresses different duct static pressure control strategies which could be implemented in variable air volume air-conditioning systems (VAV. Two pressure reset control strategies are compared to the commonly used control solution based on the “Constant static pressure” method. First pressure reset control strategy, known as PID Control, uses signals from VAV boxes controllers to reset duct static pressure in a way that one of the VAV dampers is maintained almost entirely open. Second strategy decreases static pressure setpoint until an adjustable number of pressure requests occur. As a response to the certain amount of requests, static pressure setpoint is increased. This strategy is called Trim & Respond. Both static pressure reset control strategies described in this paper are considered to have more significant potential for energy savings than the “Constant static pressure” method. In order to validate this potential, several simulations for different control strategies were carried out and the obtained results are compared and analysed. The theoretical limit of the energy savings - set of the optimal control actions, was estimated with Nelder-Mead algorithm and also presented in this article. General description of the static pressure control strategies "Constant static pressure", PID Control and Trim & Respond is given.

  15. Pressure ulcers: effectiveness of risk-assessment tools. A randomised controlled trial (the ULCER trial).

    Science.gov (United States)

    Webster, Joan; Coleman, Kerrie; Mudge, Alison; Marquart, Louise; Gardner, Glenn; Stankiewicz, Monica; Kirby, Julie; Vellacott, Catherine; Horton-Breshears, Margaret; McClymont, Alice

    2011-04-01

    To evaluate the effectiveness of two pressure-ulcer screening tools against clinical judgement in preventing pressure ulcers. A single blind randomised controlled trial. A large metropolitan tertiary hospital. 1231 patients admitted to internal medicine or oncology wards. Patients were excluded if their hospital stay was expected to be 2 days or less. Participants allocated to either a Waterlow (n=410) or Ramstadius (n=411) screening tool group or to a clinical judgement group (n=410) where no formal risk screening instrument was used. Incidence of hospital acquired pressure ulcers ascertained by regular direct observation. Use of any devices for the prevention of pressure ulcers, documentation of a pressure plan and any dietetic or specialist skin integrity review were recorded. On admission, 71 (5.8%) patients had an existing pressure ulcer. The incidence of hospital-acquired pressure ulcers was similar between groups (clinical judgement 28/410 (6.8%); Waterlow 31/411 (7.5%); Ramstadius 22/410 (5.4%), p=0.44). Significant associations with pressure injury in regression modelling included requiring a dietetic referral, being admitted from a location other than home and age over 65 years. The authors found no evidence to show that two common pressure-ulcer risk-assessment tools are superior to clinical judgement to prevent pressure injury. Resources associated with use of these tools might be better spent on careful daily skin inspection and improving management targetted at specific risks. The trial was registered with the Australian and New Zealand Clinicat Trials Registry (ACTRN 12608000541303).

  16. Dynamic target high pressure control of a VRF system for heating energy savings

    International Nuclear Information System (INIS)

    Yun, Geun Young; Lee, Je Hyeon; Kim, Inhan

    2017-01-01

    Highlights: • We developed the dynamic target high pressure control of a VRF system. • We created the VRF control model using the EnergyPlus runtime language. • Multicalorimeter experimental results indicate that the energy efficiency improved by 21%. • EnergyPlus simulations demonstrate that the annual heating energy consumption was lowered by 22%. - Abstract: Variable refrigerant flow (VRF) systems are widely used because of their ability to provide individualized comfort control with energy-saving potential. This study develops load responsive high pressure control of a VRF system with the aim of reducing the heating energy consumption of a VRF system under part load conditions. The developed control consists of two parts: one part that determines the level of heating load, and the other that assigns a target high pressure based on the level of heating load. In this way, the compressor speed can be accurately matched to heating load, which improves the energy performance of the VRF system. A series of multicalorimeter experiments revealed that the heating capacity of the VRF system varied by 45% by modulating the target high pressure and that its efficiency was enhanced by 21% by changing the high pressure from 30 kgf/cm"2 to 25 kgf/cm"2. To evaluate the annual heating energy performance of the VRF system with the developed control, a custom computer code was developed to implement the developed control using a programming language called EnergyPlus Runtime Language. Simulation outcomes showed that the annual heating energy consumption of a medium-size office building was reduced by 22% when the developed control was applied.

  17. Blood Pressure Control in Hypertensive Patients in the "Hiperdia Program": A Territory-Based Study

    Directory of Open Access Journals (Sweden)

    Clarita Silva de Souza

    2014-06-01

    Full Text Available Background: Systemic hypertension is highly prevalent and an important risk factor for cardiovascular events. Blood pressure control in hypertensive patients enrolled in the Hiperdia Program, a program of the Single Health System for the follow-up and monitoring of hypertensive patients, is still far below the desired level. Objective: To describe the epidemiological profile and to assess blood pressure control of patients enrolled in Hiperdia, in the city of Novo Hamburgo (State of Rio Grande do Sul, Brazil. Methods: Cross-sectional study with a stratified cluster random sample, including 383 adults enrolled in the Hiperdia Program of the 15 Basic Health Units of the city of Porto Alegre, conducted between 2010 and 2011. Controlled blood pressure was defined as ≤140 mmHg × 90 mmHg. The hypertensive patients were interviewed and their blood pressure was measured using a calibrated aneroid device. Prevalence ratios (PR with 95% confidence interval, Wald's χ2 test, and simple and multiple Poisson regression were used in the statistical analysis. Results: The mean age was 63 ± 10 years, and most of the patients were females belonging to social class C, with a low level of education, a sedentary lifestyle, and family history positive for systemic hypertension. Diabetes mellitus (DM was observed in 31%; adherence to the antihypertensive treatment in 54.3%; and 33.7% had their blood pressure controlled. DM was strongly associated with inadequate BP control, with only 15.7% of the diabetics showing BP considered as controlled. Conclusion: Even for hypertensive patients enrolled in the Hiperdia Program, BP control is not satisfactorily reached or sustained. Diabetic hypertensive patients show the most inappropriate BP control.

  18. Well control during the drilling and testing of high pressure offshore wells

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This Code has been prepared for use as a guide to safe practice for those concerned with well control during the drilling and testing of high pressure offshore wells. It is intended to provide information and guidance on those well control activities associated with high pressure wells which have an impact on safety offshore, and therefore require detailed care and attention. The Code has been produced in a United Kingdom Continental Shelf (UKCS) context, but the principles and recommendations have general relevance to similar operations elsewhere. (author)

  19. Control of Variable-Speed Pressurization Fan for an Offshore HVAC System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Pedersen, Simon; Løhndorf, Petar Durdevic

    2014-01-01

    all the way above the ambient pressure according to safety regulations. Meanwhile, the indoor air needs to be regularly changed in order to guarantee the indoor air quality. Both requirements could be possibly achieved by automatically manipulating either the throttle valve located at the terminal....... This paper proposes a set of control solutions to regulate the variablespeed pressurization fan system such that the energy efficiency of the considered HVAC system can be explicitly considered. A combined feed-forward with a PI-based feedback control solution, and a MPC solution are proposed based...

  20. Microbiomes of the normal middle ear and ears with chronic otitis media.

    Science.gov (United States)

    Minami, Shujiro B; Mutai, Hideki; Suzuki, Tomoko; Horii, Arata; Oishi, Naoki; Wasano, Koichiro; Katsura, Motoyasu; Tanaka, Fujinobu; Takiguchi, Tetsuya; Fujii, Masato; Kaga, Kimitaka

    2017-10-01

    The aim of this study was to profile and compare the middle ear microbiomes of human subjects with and without chronic otitis media. Prospective multicenter cohort study. All consecutive patients undergoing tympanoplasty surgery for chronic otitis media or ear surgery for conditions other than otitis media were recruited. Sterile swab samples were collected from the middle ear mucosa during surgery. The variable region 4 of the 16S rRNA gene in each sample were amplified using region-specific primers adapted for the Illumina MiSeq sequencer (Illumina, CA, USA)). The sequences were subjected to local blast and classified using Metagenome@KIN (World Fusion, Tokyo, Japan). In total, 155 participants were recruited from seven medical centers. Of these, 88 and 67 had chronic otitis media and normal middle ears, respectively. The most abundant bacterial phyla on the mucosal surfaces of the normal middle ears were Proteobacteria, followed by Actinobacteria, Firmicutes, and Bacteroidetes. The children and adults with normal middle ears differed significantly in terms of middle ear microbiomes. Subjects with chronic otitis media without active inflammation (dry ear) had similar middle ear microbiomes as the normal middle ears group. Subjects with chronic otitis media with active inflammation (wet ear) had a lower prevalence of Proteobacteria and a higher prevalence of Firmicutes than the normal middle ears. The human middle ear is inhabited by more diverse microbial communities than was previously thought. Alteration of the middle ear microbiome may contribute to the pathogenesis of chronic otitis media with active inflammation. 2b. Laryngoscope, 127:E371-E377, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  1. [Treatment of acute respiratory distress syndrome using pressure and volume controlled ventilation with lung protective strategy].

    Science.gov (United States)

    Ge, Ying; Wan, Yong; Wang, Da-qing; Su, Xiao-lin; Li, Jun-ying; Chen, Jing

    2004-07-01

    To investigate the significance and effect of pressure controlled ventilation (PCV) as well as volume controlled ventilation (VCV) by lung protective strategy on respiratory mechanics, blood gas analysis and hemodynamics in patients with acute respiratory distress syndrome (ARDS). Fifty patients with ARDS were randomly divided into PCV and VCV groups with permissive hypercapnia and open lung strategy. Changes in respiratory mechanics, blood gas analysis and hemodynamics were compared between two groups. Peak inspiration pressure (PIP) in PCV group was significantly lower than that in VCV group, while mean pressure of airway (MPaw) was significantly higher than that in VCV after 24 hours mechanical ventilation. After 24 hours mechanical ventilation, there were higher central venous pressure (CVP) and slower heart rate (HR) in two groups, CVP was significantly higher in VCV compared with PCV, and PCV group had slower HR than VCV group, the two groups had no differences in mean blood pressure (MBP) at various intervals. All patients showed no ventilator-induced lung injury. Arterial blood oxygenations were obviously improved in two groups after 24 hours mechanical ventilation, PCV group had better partial pressure of oxygen in artery (PaO2) than VCV group. Both PCV and VCV can improve arterial blood oxygenations, prevent ventilator-induced lung injury, and have less disturbance in hemodynamic parameters. PCV with lung protective ventilatory strategy should be early use for patients with ARDS.

  2. Adaptive management for subsurface pressure and plume control in application to geological CO2 storage

    Science.gov (United States)

    Gonzalez-Nicolas, A.; Cihan, A.; Birkholzer, J. T.; Petrusak, R.; Zhou, Q.; Riestenberg, D. E.; Trautz, R. C.; Godec, M.

    2016-12-01

    Industrial-scale injection of CO2 into the subsurface can cause reservoir pressure increases that must be properly controlled to prevent any potential environmental impact. Excessive pressure buildup in reservoir may result in ground water contamination stemming from leakage through conductive pathways, such as improperly plugged abandoned wells or distant faults, and the potential for fault reactivation and possibly seal breaching. Brine extraction is a viable approach for managing formation pressure, effective stress, and plume movement during industrial-scale CO2 injection projects. The main objectives of this study are to investigate suitable different pressure management strategies involving active brine extraction and passive pressure relief wells. Adaptive optimized management of CO2 storage projects utilizes the advanced automated optimization algorithms and suitable process models. The adaptive management integrates monitoring, forward modeling, inversion modeling and optimization through an iterative process. In this study, we employ an adaptive framework to understand primarily the effects of initial site characterization and frequency of the model update (calibration) and optimization calculations for controlling extraction rates based on the monitoring data on the accuracy and the success of the management without violating pressure buildup constraints in the subsurface reservoir system. We will present results of applying the adaptive framework to test appropriateness of different management strategies for a realistic field injection project.

  3. Deposition of elemental sulfur in city gate Pressure Control Valves (PCVs)

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, Thiago C. do; Veiga, Leandro S. da; Silva, Marcos J.M. da; Lemos, Marcelo C. de; Goncalves, Luciane T. [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-12-19

    Deposition of elemental sulfur has been observed in city gate pressure control valves (PCV s), a phenomenon that causes operational problems in these facilities. This article discusses the problems caused by this deposition, especially in pilots of pressure control valves. While passing through PCV s, the flow of natural gas is subjected to a sharp drop in temperature due to the reduction of pressure (Joule-Thompson). When this happens, the elemental sulfur that is in balance with the flow of natural gas is deposited inside the PCV s and the obstacles ahead. Since PCV s are self-operated and use natural gas as the working fluid, the elemental sulfur is also deposited in the pilots as well. Elemental sulfur in powder form has very small particles - around 20 {mu}m - that prevent the perfect operation of the small moving parts of pilots. Because of this, the affected pilot cannot operate the PCV satisfactorily to regulate the pressure of the natural gas supplied to the customer. There are two possible consequences of this situation: when the customer increases consumption, the pressure will decline to less than below the limit established under the supply contract, which can lead to fines; and the pressure can rise above the limit tolerated by pipes, which can lead to dangerous ruptures. (author)

  4. Blood volume, blood pressure and total body sodium: internal signalling and output control

    DEFF Research Database (Denmark)

    Bie, P

    2009-01-01

    Total body sodium and arterial blood pressure (ABP) are mutually dependent variables regulated by complex control systems. This review addresses the role of ABP in the normal control of sodium excretion (NaEx), and the physiological control of renin secretion. NaEx is a pivotal determinant of ABP......, and under experimental conditions, ABP is a powerful, independent controller of NaEx. Blood volume is a function of dietary salt intake; however, ABP is not, at least not in steady states. A transient increase in ABP after a step-up in sodium intake could provide a causal relationship between ABP...... and the regulation of NaEx via a hypothetical integrative control system. However, recent data show that subtle sodium loading (simulating salty meals) causes robust natriuresis without changes in ABP. Changes in ABP are not necessary for natriuresis. Normal sodium excretion is not regulated by pressure. Plasma...

  5. Autonomic control of body temperature and blood pressure: influences of female sex hormones.

    Science.gov (United States)

    Charkoudian, Nisha; Hart, Emma C J; Barnes, Jill N; Joyner, Michael J

    2017-06-01

    Female reproductive hormones exert important non-reproductive influences on autonomic regulation of body temperature and blood pressure. Estradiol and progesterone influence thermoregulation both centrally and peripherally, where estradiol tends to promote heat dissipation, and progesterone tends to promote heat conservation and higher body temperatures. Changes in thermoregulation over the course of the menstrual cycle and with hot flashes at menopause are mediated by hormonal influences on neural control of skin blood flow and sweating. The influence of estradiol is to promote vasodilation, which, in the skin, results in greater heat dissipation. In the context of blood pressure regulation, both central and peripheral hormonal influences are important as well. Peripherally, the vasodilator influence of estradiol contributes to the lower blood pressures and smaller risk of hypertension seen in young women compared to young men. This is in part due to a mechanism by which estradiol augments beta-adrenergic receptor mediated vasodilation, offsetting alpha-adrenergic vasoconstriction, and resulting in a weak relationship between muscle sympathetic nerve activity and total peripheral resistance, and between muscle sympathetic nerve activity and blood pressure. After menopause, with the loss of reproductive hormones, sympathetic nerve activity, peripheral resistance and blood pressure become more strongly related, and sympathetic nerve activity (which increases with age) becomes a more important contributor to the prevailing level of blood pressure. Continuing to increase our understanding of sex hormone influences on body temperature and blood pressure regulation will provide important insight for optimization of individualized health care for future generations of women.

  6. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  7. Automated Kick Control Procedure for an Influx in Managed Pressure Drilling Operations

    Directory of Open Access Journals (Sweden)

    Jing Zhou

    2016-01-01

    Full Text Available Within drilling of oil and gas wells, the Managed Pressure Drilling (MPD method with active control of wellbore pressure during drilling has partly evolved from conventional well control procedures. However, for MPD operations the instrumentation is typically more extensive compared to conventional drilling. Despite this, any influx of formation fluids (commonly known as a kick during MPD operations is typically handled by conventional well control methods, at least if the kick is estimated to be larger than a threshold value. Conventional well control procedures rely on manual control of the blow out preventer, pumps, and choke valves and do not capitalize on the benefits from the instrumentation level associated with MPD. This paper investigates two alternative well control procedures specially adapted to backpressure MPD: the dynamic shut-in (DSI procedure and the automatic kick control (AKC procedure. Both methods capitalize on improvements in Pressure While Drilling (PWD technology. A commercially available PWD tool buffers high-resolution pressure measurements, which can be used in an automated well control procedure. By using backpressure MPD, the choke valve opening is tuned automatically using a feedback-feedforward control method. The two procedures are evaluated using a high fidelity well flow model and cases from a North Sea drilling operation are simulated. The results show that using AKC procedure reduces the time needed to establish control of the well compared to DSI procedure. It also indicates that the AKC procedure reduces the total kick size compared to the DSI procedure, and thereby reduces the risk of lost circulation.

  8. Influence of dental occlusion on postural control and plantar pressure distribution.

    Science.gov (United States)

    Scharnweber, Benjamin; Adjami, Frederic; Schuster, Gabriele; Kopp, Stefan; Natrup, Jörg; Erbe, Christina; Ohlendorf, Daniela

    2017-11-01

    The number of studies investigating correlations between the temporomandibular system and body posture, postural control or plantar pressure distribution is continuously increasing. If a connection can be found, it is often of minor influence or for only a single parameter. However, small subject groups are critical. This study was conducted to define correlations between dental parameters, postural control and plantar pressure distribution in healthy males. In this study, 87 male subjects with an average age of 25.23 ± 3.5 years (ranging from 18 to 35 years) were examined. Dental casts of the subjects were analyzed. Postural control and plantar pressure distribution were recorded by a force platform. Possible orthodontic and orthopedic factors of influence were determined by either an anamnesis or a questionnaire. All tests performed were randomized and repeated three times each for intercuspal position (ICP) and blocked occlusion (BO). For a statistical analysis of the results, non-parametric tests (Wilcoxon-Matched-Pairs-Test, Kruskall-Wallis-Test) were used. A revision of the results via Bonferroni-Holm correction was considered. ICP increases body sway in the frontal (p ≤ 0.01) and sagittal planes (p ≤ 0.03) compared to BO, whereas all other 29 correlations were independent of the occlusion position. For both of the ICP or BO cases, Angle-class, midline-displacement, crossbite, or orthodontic therapy were found to have no influence on postural control or plantar pressure distribution (p > 0.05). However, the contact time of the left foot decreased (p ≤ 0.001) while detecting the plantar pressure distribution in each position. Persistent dental parameters have no effect on postural sway. In addition, postural control and plantar pressure distribution have been found to be independent postural criteria.

  9. Reducing the pressure drag of a D-shaped bluff body using linear feedback control

    Science.gov (United States)

    Dalla Longa, L.; Morgans, A. S.; Dahan, J. A.

    2017-12-01

    The pressure drag of blunt bluff bodies is highly relevant in many practical applications, including to the aerodynamic drag of road vehicles. This paper presents theory revealing that a mean drag reduction can be achieved by manipulating wake flow fluctuations. A linear feedback control strategy then exploits this idea, targeting attenuation of the spatially integrated base (back face) pressure fluctuations. Large-eddy simulations of the flow over a D-shaped blunt bluff body are used as a test-bed for this control strategy. The flow response to synthetic jet actuation is characterised using system identification, and controller design is via shaping of the frequency response to achieve fluctuation attenuation. The designed controller successfully attenuates integrated base pressure fluctuations, increasing the time-averaged pressure on the body base by 38%. The effect on the flow field is to push the roll-up of vortices further downstream and increase the extent of the recirculation bubble. This control approach uses only body-mounted sensing/actuation and input-output model identification, meaning that it could be applied experimentally.

  10. Investigation on Active Thermal Control Method with Pool Boiling Heat Transfer at Low Pressure

    Science.gov (United States)

    Sun, Chuang; Guo, Dong; Wang, Zhengyu; Sun, Fengxian

    2018-06-01

    In order to maintain a desirable temperature level of electronic equipment at low pressure, the thermal control performance with pool boiling heat transfer of water was examined based on experimental measurement. The total setup was designed and performed to accomplish the experiment with the pressure range from 4.5 kPa to 20 kPa and the heat flux between 6 kW/m2 and 20 kW/m2. The chosen material of the heat surface was aluminium alloy and the test cavity had the capability of varying the direction for the heat surface from vertical to horizontal directions. Through this study, the steady and transient temperature of the heat surface at different pressures and directions were obtained. Although the temperature non-uniformity of the heat surface from the centre to the edge could reach 10°C for the aluminium alloy due to the varying pressures, the whole temperature results successfully satisfied with the thermal control requirements for electronic equipment, and the temperature control effect of the vertically oriented direction was better than that of the horizontally oriented direction. Moreover, the behaviour of bubbles generating and detaching from the heat surface was recorded by a high-resolution camera, so as to understand the pool boiling heat transfer mechanism at low-load heat flux. These pictures showed that the bubbles departure diameter becomes larger, and departure frequency was slower at low pressure, in contrast to 1.0 atm.

  11. Age effects in the human middle ear: Wideband acoustical measures

    Science.gov (United States)

    Feeney, M. Patrick; Sanford, Chris A.

    2004-12-01

    Studies that have examined age effects in the human middle ear using either admittance measures at 220 or 660 Hz or multifrequency tympanometry from 200 to 2000 Hz have had conflicting results. Several studies have suggested an increase in admittance with age, while several others have suggested a decrease in admittance with age. A third group of studies found no significant age effect. This study examined 226 Hz tympanometry and wideband energy reflectance and impedance at ambient pressure in a group of 40 young adults and a group of 30 adults with age >=60 years. The groups did not differ in admittance measures of the middle ear at 226 Hz. However, significant age effects were found in wideband energy reflectance and impedance. In particular, in older adults there was a comparative decrease in reflectance from 800 to 2000 Hz but an increase near 4000 Hz. The results suggest a decrease in middle-ear stiffness with age. The findings of this study hold relevance for understanding the aging process in the auditory system, for the establishment of normative data for wideband energy reflectance, for the possibility of a conductive component to presbycusis, and for the interpretation of otoacoustic emission measurements. .

  12. Reversible Morphological Control of Tubulin-Encapsulating Giant Liposomes by Hydrostatic Pressure.

    Science.gov (United States)

    Hayashi, Masahito; Nishiyama, Masayoshi; Kazayama, Yuki; Toyota, Taro; Harada, Yoshie; Takiguchi, Kingo

    2016-04-19

    Liposomes encapsulating cytoskeletons have drawn much recent attention to develop an artificial cell-like chemical-machinery; however, as far as we know, there has been no report showing isothermally reversible morphological changes of liposomes containing cytoskeletons because the sets of various regulatory factors, that is, their interacting proteins, are required to control the state of every reaction system of cytoskeletons. Here we focused on hydrostatic pressure to control the polymerization state of microtubules (MTs) within cell-sized giant liposomes (diameters ∼10 μm). MT is the cytoskeleton formed by the polymerization of tubulin, and cytoskeletal systems consisting of MTs are very dynamic and play many important roles in living cells, such as the morphogenesis of nerve cells and formation of the spindle apparatus during mitosis. Using real-time imaging with a high-pressure microscope, we examined the effects of hydrostatic pressure on the morphology of tubulin-encapsulating giant liposomes. At ambient pressure (0.1 MPa), many liposomes formed protrusions due to tubulin polymerization within them. When high pressure (60 MPa) was applied, the protrusions shrank within several tens of seconds. This process was repeatedly inducible (around three times), and after the pressure was released, the protrusions regenerated within several minutes. These deformation rates of the liposomes are close to the velocities of migrating or shape-changing living cells rather than the shortening and elongation rates of the single MTs, which have been previously measured. These results demonstrate that the elongation and shortening of protrusions of giant liposomes is repeatedly controllable by regulating the polymerization state of MTs within them by applying and releasing hydrostatic pressure.

  13. Computer-controlled pneumatic pressure algometry--a new technique for quantitative sensory testing.

    Science.gov (United States)

    Polianskis, R; Graven-Nielsen, T; Arendt-Nielsen, L

    2001-01-01

    Hand-held pressure algometry usually assesses pressure-pain detection thresholds and provides little information on pressure-pain stimulus-response function. In this article, a cuff pressure algometry for advanced pressure-pain function evaluation is proposed. The experimental set-up consisted of a pneumatic tourniquet cuff, a computer-controlled air compressor and an electronic visual analogue scale (VAS) for constant pain intensity rating. Twelve healthy volunteers were included in the study. In the first part, hand-held algometry and cuff algometry were performed over the gastrocnemius muscle with constant compression rate. In the second part, the cuff algometry was performed with different compression rates to evaluate the influence of the compression rate on pain thresholds and other psychophysical data. Pressure-pain detection threshold (PDT), pain tolerance threshold (PTT), pain intensity, PDT-PTT time and other psychophysical variables were evaluated.Pressure-pain detection thresholds recorded over the gastrocnemius muscle with a hand-held and with a cuff algometer, were 482 +/- 19 kPa and 26 +/- 1.6 kPa, respectively. Pressure and pain intensities were correlated during cuff algometry. During increasing cuff compression, the subjective pain tolerance limit on VAS was 5.6 +/- 0.95 cm. There was a direct correlation between the number of compressions, the compression rate and pain thresholds. The cuff algometry technique is appropriate for pressure-pain stimulus-response studies. Cuff algometry allowed quantification of psychophysical response to the change of stimulus configuration. Copyright 2001 European Federation of Chapters of the International Association for the Study of Pain.

  14. Cost-Effectiveness of Intensive versus Standard Blood-Pressure Control.

    Science.gov (United States)

    Bress, Adam P; Bellows, Brandon K; King, Jordan B; Hess, Rachel; Beddhu, Srinivasan; Zhang, Zugui; Berlowitz, Dan R; Conroy, Molly B; Fine, Larry; Oparil, Suzanne; Morisky, Donald E; Kazis, Lewis E; Ruiz-Negrón, Natalia; Powell, Jamie; Tamariz, Leonardo; Whittle, Jeff; Wright, Jackson T; Supiano, Mark A; Cheung, Alfred K; Weintraub, William S; Moran, Andrew E

    2017-08-24

    In the Systolic Blood Pressure Intervention Trial (SPRINT), adults at high risk for cardiovascular disease who received intensive systolic blood-pressure control (target, control (target, costs associated with intensive control versus standard control. We used a microsimulation model to apply SPRINT treatment effects and health care costs from national sources to a hypothetical cohort of SPRINT-eligible adults. The model projected lifetime costs of treatment and monitoring in patients with hypertension, cardiovascular disease events and subsequent treatment costs, treatment-related risks of serious adverse events and subsequent costs, and quality-adjusted life-years (QALYs) for intensive control versus standard control of systolic blood pressure. We determined that the mean number of QALYs would be 0.27 higher among patients who received intensive control than among those who received standard control and would cost approximately $47,000 more per QALY gained if there were a reduction in adherence and treatment effects after 5 years; the cost would be approximately $28,000 more per QALY gained if the treatment effects persisted for the remaining lifetime of the patient. Most simulation results indicated that intensive treatment would be cost-effective (51 to 79% below the willingness-to-pay threshold of $50,000 per QALY and 76 to 93% below the threshold of $100,000 per QALY), regardless of whether treatment effects were reduced after 5 years or persisted for the remaining lifetime. In this simulation study, intensive systolic blood-pressure control prevented cardiovascular disease events and prolonged life and did so at levels below common willingness-to-pay thresholds per QALY, regardless of whether benefits were reduced after 5 years or persisted for the patient's remaining lifetime. (Funded by the National Heart, Lung, and Blood Institute and others; SPRINT ClinicalTrials.gov number, NCT01206062 .).

  15. Better well control through safe drilling margin identification, influx analysis and direct bottom hole pressure control method for deep water

    Energy Technology Data Exchange (ETDEWEB)

    Veeningen, Daan [National Oilwell Varco IntelliServ (NOV), Houston, TX (United States)

    2012-07-01

    Currently, well control events are almost exclusively detected by using surface measurements. Measuring a volume increase in the 'closed loop' mud circulation system; a standpipe pressure decrease; or changes in a variety of drilling parameters provide indicators of a kick. Especially in deep water, where the riser comprises a substantial section of the well bore, early kick detection is paramount for limiting the severity of a well bore influx and improve the ability to regain well control. While downhole data is presently available from downhole tools nearby the bit, available data rates are sparse as mud pulse telemetry bandwidth is limited and well bore measurements compete with transmission of other subsurface data. Further, data transfer is one-directional, latency is significant and conditions along the string are unknown. High-bandwidth downhole data transmission system, via a wired or networked drill string system, has the unique capability to acquire real-time pressure and temperature measurement at a number of locations along the drill string. This system provides high-resolution downhole data available at very high speed, eliminating latency and restrictions that typically limit the availability of downhole data. The paper describes well control opportunities for deep water operations through the use of downhole data independent from surface measurements. First, the networked drill string provides efficient ways to identify pore pressure, fracture gradient, and true mud weight that comprise the safe drilling margin. Second, the independent measurement capability provides early kick detection and improved ability to analyze an influx even with a heterogeneous mud column through distributed along-string annular pressure measurements. Third, a methodology is proposed for a direct measurement method using downhole real-time pressure for maintaining constant bottom hole pressure during well kills in deep water. (author)

  16. Acceleration induced water removal from ear canals.

    Science.gov (United States)

    Kang, Hosung; Averett, Katelee; Jung, Sunghwan

    2017-11-01

    Children and adults commonly experience having water trapped in the ear canals after swimming. To remove the water, individuals will shake their head sideways. Since a child's ear canal has a smaller diameter, it requires more acceleration of the head to remove the trapped water. In this study, we theoretically and experimentally investigated the acceleration required to break the surface meniscus of the water in artificial ear canals and hydrophobic-coated glass tubes. In experiments, ear canal models were 3D-printed from a CT-scanned human head. Also, glass tubes were coated with silane to match the hydrophobicity in ear canals. Then, using a linear stage, we measured the acceleration values required to forcefully eject the water from the artificial ear canals and glass tubes. A theoretical model was developed to predict the critical acceleration at a given tube diameter and water volume by using a modified Rayleigh-Taylor instability. Furthermore, this research can shed light on the potential of long-term brain injury and damage by shaking the head to push the water out of the ear canal. This research was supported by National Science Foundation Grant CBET-1604424.

  17. Intensive Versus Standard Blood Pressure Control in SPRINT-Eligible Participants of ACCORD-BP.

    Science.gov (United States)

    Buckley, Leo F; Dixon, Dave L; Wohlford, George F; Wijesinghe, Dayanjan S; Baker, William L; Van Tassell, Benjamin W

    2017-12-01

    We sought to determine the effect of intensive blood pressure (BP) control on cardiovascular outcomes in participants with type 2 diabetes mellitus (T2DM) and additional risk factors for cardiovascular disease (CVD). This study was a post hoc, multivariate, subgroup analysis of ACCORD-BP (Action to Control Cardiovascular Risk in Diabetes Blood Pressure) participants. Participants were eligible for the analysis if they were in the standard glucose control arm of ACCORD-BP and also had the additional CVD risk factors required for SPRINT (Systolic Blood Pressure Intervention Trial) eligibility. We used a Cox proportional hazards regression model to compare the effect of intensive versus standard BP control on CVD outcomes. The "SPRINT-eligible" ACCORD-BP participants were pooled with SPRINT participants to determine whether the effects of intensive BP control interacted with T2DM. The mean baseline Framingham 10-year CVD risk scores were 14.5% and 14.8%, respectively, in the intensive and standard BP control groups. The mean achieved systolic BP values were 120 and 134 mmHg in the intensive and standard BP control groups ( P control reduced the composite of CVD death, nonfatal myocardial infarction (MI), nonfatal stroke, any revascularization, and heart failure (hazard ratio 0.79; 95% CI 0.65-0.96; P = 0.02). Intensive BP control also reduced CVD death, nonfatal MI, and nonfatal stroke (hazard ratio 0.69; 95% CI 0.51-0.93; P = 0.01). Treatment-related adverse events occurred more frequently in participants receiving intensive BP control (4.1% vs. 2.1%; P = 0.003). The effect of intensive BP control on CVD outcomes did not differ between patients with and without T2DM ( P > 0.62). Intensive BP control reduced CVD outcomes in a cohort of participants with T2DM and additional CVD risk factors. © 2017 by the American Diabetes Association.

  18. Ear canal collapse prevalence and associated factors among users of a center of prevention and rehabilitation for disabilities

    Directory of Open Access Journals (Sweden)

    Elisana Costa Dourado

    Full Text Available ABSTRACT Purpose: to investigate the prevalence of the ear canal collapse when using supra-aural earphones and to verify if this event is influenced by sex, age, color of the skin and prominent ear. Methods: the collapse was assessed by a visual inspection after the positioning of a detached cushion, pressured against the external ear. Results: a total of 436 individuals, aged 3 to 97 years, participated in the study. Ear canal collapse was observed in 11.4% of the subjects, being mostly bilateral (90.0%. The prevalence ranged from 6.3% to 36.6% across age groups. Males, aged 65 years or above and presence of prominent ear were independently identified as associated factors for the occurrence of ear canal collapse (p<0.05. Despite a higher prevalence for those self-identified as white skinned when compared to non-whites, the difference was not statistically significant. Conclusion: the ear canal collapse, when supra-aural earphones are used, is more likely to occur in men, in elderly people, and among those with prominent ears. The prevalence of the event in this population raises the necessity of a careful examination, previous to any evaluation using supra-aural earphones.

  19. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial.

    Science.gov (United States)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter; Gregers Petersen, Hans; Benee Olsen, David; Berg, Ronan M G; Abrahamsen, Henrik; Wiinberg, Niels

    2018-01-17

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark. One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent home blood pressure monitoring and 24-hour ambulatory blood pressure monitoring. Mean day- and night-time systolic and diastolic 24-hour ambulatory blood pressure. Change in systolic and diastolic office blood pressure and change in cardiovascular risk profile. Of the patients, 515 (49%) were allocated to the usual group, and 533 (51%) to the intensive group. The reductions in day- and night-time 24-hour ambulatory blood pressure were similar (usual group: 4.6 ± 13.5/2.8 ± 82 mmHg; intensive group: 5.6 ± 13.0/3.5 ± 8.2 mmHg; P = 0.27/P = 0.20). Cardiovascular risk scores were reduced in both groups at follow-up, but more so in the intensive than in the usual group (P = 0.02). An intensive blood pressure monitoring strategy led to a similar blood pressure reduction to conventional monitoring. However, the intensive strategy appeared to improve patients' cardiovascular risk profile through other effects than a reduction of blood pressure. Clinical Trials NCT00244660. © The Author 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Piezoelectric microvalve for precise control of gas flow at high pressure

    NARCIS (Netherlands)

    Fazal, I.; Elwenspoek, Michael Curt

    2008-01-01

    We present a normally open piezoelectric actuated micro valve, based on the novel concept of micro and fine machining technology. This new design allows a wide controllable range for high flow at a high pressure difference between inlet and outlet. This promising combination of micro and fine

  1. CDC Vital Signs: Blood Pressure Control -- Helping Patients Take Their Medicine

    Science.gov (United States)

    ... pharmacists, and patients. Increase access to Medication Therapy Management services for at-risk patients with chronic disease. http://go.usa.gov/ ... of interventions on medication adherence and blood pressure control in patients ... of Internal Medicine – The implications of therapeutic complexity on adherence ...

  2. Glovebox with purification and pressure control of the neutral gas atmosphere in closed circuit

    International Nuclear Information System (INIS)

    Cadrot, J.

    1990-01-01

    In the gas main are placed 2 series of specific gas purifiers in parallel. Pressure is controlled with a buffer tank two three way solenoid value upstream and down stream a compressor and a supercharger. A checking board allows continuous monitoring of circuit tightness [fr

  3. Why business unit controllers bias accounting figures: Involvement in management, social pressure and Machiavellianism

    NARCIS (Netherlands)

    Maas, V.S.; Hartmann, F.G.H.

    2009-01-01

    This paper investigates why some business unit controllers are more likely to deliberately bias accounting data than others. Different from the existing literature, we argue that involvement in management and social pressure are neither necessary, nor sufficient conditions for biasing behavior.

  4. Hydrostatic-pressure and uniaxial-strain experiments for controlling the spin-Peierls transition

    International Nuclear Information System (INIS)

    Mito, Masaki; Deguchi, Hiroyuki; Fujita, Wataru; Kondo, Ryusuke; Kagoshima, Seiichi

    2010-01-01

    The spin-Peierls (SP) system is considered to be a quantum spin system strongly coupled with the lattice. We have succeeded in controlling SP transition by applying hydrostatic pressure and/or uniaxial strain. The observed phenomenon could be a typical example for understanding the SP transition based on the Hamiltonian. (author)

  5. Control of relative radiation pressure in optical traps : application to phagocytic membrane binding studies

    NARCIS (Netherlands)

    Kress, H.; Stelzer, E.H.K.; Griffiths, G.; Rohrbach, A.

    2005-01-01

    We show how to control the relative radiation pressure and thereby the stable trap position of an optically trapped bead by variation of the mean incident axial photon momentum. The thermal position fluctuations of a trapped bead are recorded by a three-dimensional back focal plane interferometry.

  6. Design issues of a back-pressure-based congestion control mechanism

    NARCIS (Netherlands)

    Malhotra, R.; Mandjes, M.R.H.; Scheinhardt, W.R.W.; Berg, van den J.L.

    2008-01-01

    Congestion control in packet-based networks is often realized by feedback protocols -- in this paper we assess the performance under a back-pressure mechanism that has been proposed and standardized for Ethernet metropolitan networks. Relying on our earlier results for feedback fluid queues, we

  7. Modeling and control of diffusion and low-pressure chemical vapor deposition furnaces

    Science.gov (United States)

    De Waard, H.; De Koning, W. L.

    1990-03-01

    In this paper a study is made of the heat transfer inside cylindrical resistance diffusion and low-pressure chemical vapor deposition furnaces, aimed at developing an improved temperature controller. A model of the thermal behavior is derived which also covers the important class of furnaces equipped with semitransparent quartz process tubes. The model takes into account the thermal behavior of the thermocouples. It is shown that currently used temperature controllers are highly inefficient for very large scale integration applications. Based on the model an alternative temperature controller of the linear-quadratic-Gaussian type is proposed which features direct wafer temperature control. Some simulation results are given.

  8. Multimorbidity and blood pressure control in 37 651 hypertensive patients from Danish general practice

    DEFF Research Database (Denmark)

    Paulsen, Maja Skov; Andersen, Morten; Thomsen, Janus L

    2013-01-01

    Patients with hypertension are primarily treated in general practice. However, major studies of patients with hypertension are rarely based on populations from primary care. Knowledge of blood pressure (BP) control rates in patients with diabetes and/or cardiovascular diseases (CVDs), who have...... additional comorbidities, is lacking. We aimed to investigate the association of comorbidities with BP control using a large cohort of hypertensive patients from primary care practices....

  9. Selecting the Protective Ear Plugs

    Directory of Open Access Journals (Sweden)

    Manouchehr Omidvari

    1999-03-01

    Full Text Available Exposure to noise is a one of the common problems in any industrial places. Many solutions have been introduced to overcome the deleterious effects of noise pollution maintaining and repairing systems in the equipments, environmental control and hearing conservation systems are some of these solutions that could be mentioned. "nThere are various types of Hearing protection devices and each one is useful under special circumstances. Commonly, different Hearing protection devices have a particular brochure to introduce information about the manufacturers and the quality of noise reduction in that special production. "nThree different methods are commonly used to determine the noise reduction factor in various Hearing protection devices. All these methods have been presented based on the mathematical evaluations and according to the spectral features of the sound existing in the environment and then the sound pressure level is determined in dBA. In the current article we will have a look on the mentioned arithmetic models and their special characteristics.

  10. Effect of melatonin on nocturnal blood pressure: meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Laudon M

    2011-09-01

    Full Text Available Ehud Grossman1,4, Moshe Laudon2, Nava Zisapel2,31Department of Internal Medicine D and Hypertension Unit, The Chaim Sheba Medical Center, Tel-Hashomer, Israel; 2Neurim Pharmaceuticals Ltd, Tel Aviv, Israel and 3Department of Neurobiology, Faculty of Life Sciences, Tel Aviv University, Tel Aviv, Israel; 4Sackler School of Medicine, Tel Aviv University, Tel Aviv, IsraelBackground: Patients with nocturnal hypertension are at higher risk for cardiovascular complications such as myocardial infarction and cerebrovascular insult. Published studies inconsistently reported decreases in nocturnal blood pressure with melatonin.Methods: A meta-analysis of the efficacy and safety of exogenous melatonin in ameliorating nocturnal blood pressure was performed using a random effects model of all studies fitting the inclusion criteria, with subgroup analysis of fast-release versus controlled-release preparations.Results: Seven trials (three of controlled-release and four of fast-release melatonin with 221 participants were included. Meta-analysis of all seven studies did not reveal significant effects of melatonin versus placebo on nocturnal blood pressure. However, subgroup analysis revealed that controlled-release melatonin significantly reduced nocturnal blood pressure whereas fast-release melatonin had no effect. Systolic blood pressure decreased significantly with controlled-release melatonin (-6.1 mmHg; 95% confidence interval [CI] -10.7 to -1.5; P = 0.009 but not fast-release melatonin (-0.3 mmHg; 95% CI -5.9 to 5.30; P = 0.92. Diastolic blood pressure also decreased significantly with controlled-release melatonin (-3.5 mmHg; 95% CI -6.1 to -0.9; P = 0.009 but not fast-release melatonin (-0.2 mmHg; 95% CI -3.8 to 3.3; P = 0.89. No safety concerns were raised.Conclusion: Add-on controlled-release melatonin to antihypertensive therapy is effective and safe in ameliorating nocturnal hypertension, whereas fast-release melatonin is ineffective. It is necessary

  11. Mammographic compression after breast conserving therapy: Controlling pressure instead of force

    International Nuclear Information System (INIS)

    Groot, J. E. de; Branderhorst, W.; Grimbergen, C. A.; Broeders, M. J. M.; Heeten, G. J. den

    2014-01-01

    Purpose: X-ray mammography is the primary tool for early detection of breast cancer and for follow-up after breast conserving therapy (BCT). BCT-treated breasts are smaller, less elastic, and more sensitive to pain. Instead of the current force-controlled approach of applying the same force to each breast, pressure-controlled protocols aim to improve standardization in terms of physiology by taking breast contact area and inelasticity into account. The purpose of this study is to estimate the potential for pressure protocols to reduce discomfort and pain, particularly the number of severe pain complaints for BCT-treated breasts. Methods: A prospective observational study including 58 women having one BCT-treated breast and one untreated nonsymptomatic breast, following our hospital's 18 decanewton (daN) compression protocol was performed. Breast thickness, applied force, contact area, mean pressure, breast volume, and inelasticity (mean E-modulus) were statistically compared between the within-women breast pairs, and data were used as predictors for severe pain, i.e., scores 7 and higher on an 11-point Numerical Rating Scale. Curve-fitting models were used to estimate how pressure-controlled protocols affect breast thickness, compression force, and pain experience. Results: BCT-treated breasts had on average 27% smaller contact areas, 30% lower elasticity, and 30% higher pain scores than untreated breasts (allp 2 decrease in contact area, as well as increased pain sensitivity, BCT-breasts had on average 5.3 times higher odds for severe pain than untreated breasts. Model estimations for a pressure-controlled protocol with a 10 kPa target pressure, which is below normal arterial pressure, suggest an average 26% (range 10%–36%) reduction in pain score, and an average 77% (range 46%–95%) reduction of the odds for severe pain. The estimated increase in thickness is +6.4% for BCT breasts. Conclusions: After BCT, women have hardly any choice in avoiding an annual

  12. Imaging of the postoperative middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Marc T. [Department of Medical Imaging, Fondation Ophtalmologique Adolphe de Rothschild, 25 rue Manin, 75940, Paris (France); Ayache, Denis [Department of Otorhinolaryngology, Fondation Ophtalmologique Adolphe de Rothschild, Paris (France)

    2004-03-01

    The aim of this article is twofold: (a) to present the principles and the indications of surgical treatment of middle ear pathologies; and (b) to review the imaging findings after middle ear surgery, including the normal postoperative aspects and imaging findings in patients presenting with unsatisfactory surgical results or with suspicion of postoperative complications. This review is intentionally restricted to the most common diseases involving the middle ear: chronic otitis media and otosclerosis. In these specific fields of interest, CT and MR imaging play a very important role in the postoperative follow-up and in the work-up of surgical failures and complications. (orig.)

  13. EARS: Electronic Access to Reference Service.

    Science.gov (United States)

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  14. Pharmacist Intervention for Blood Pressure Control in Patients with Diabetes and/or Chronic Kidney Disease.

    Science.gov (United States)

    Anderegg, Maxwell D; Gums, Tyler H; Uribe, Liz; MacLaughlin, Eric J; Hoehns, James; Bazaldua, Oralia V; Ives, Timothy J; Hahn, David L; Coffey, Christopher S; Carter, Barry L

    2018-03-01

    The objectives of this study were to determine if hypertensive patients with comorbid diabetes mellitus (DM) and/or chronic kidney disease (CKD) receiving a pharmacist intervention had a greater reduction in mean blood pressure (BP) and improved BP control at 9 months compared with those receiving usual care; and compare Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) guideline and 2014 guideline (JNC 8) BP control rates in patients with DM and/or CKD. This cluster randomized trial included 32 medical offices in 15 states. Clinical pharmacists made treatment recommendations to physicians at intervention sites. This post hoc analysis evaluated mean BP and BP control rates in the intervention and control groups. The study included 335 patients (227 intervention, 108 control) when mean BP and control rates were evaluated by JNC 7 inclusion and control criteria. When JNC 8 inclusion and control criteria were applied, 241 patients (165 intervention, 76 control) remained and were included in the analysis. The pharmacist-intervention group had significantly greater mean systolic blood pressure reduction compared with usual care at 9 months (8.64 mm Hg; 95% confidence interval [CI] -12.8 to -4.49, pcontrol at 9 months than usual care by either the JNC 7 or JNC 8 inclusion and control groups (adjusted odds ratio [OR] 1.97, 95% CI 1.01-3.86, p=0.0470 and OR 2.16, 95% CI 1.21-3.85, p=0.0102, respectively). This study demonstrated that a physician-pharmacist collaborative intervention was effective in reducing mean systolic BP and improving BP control in patients with uncontrolled hypertension with DM and/or CKD, regardless of which BP guidelines were used. © 2018 Pharmacotherapy Publications, Inc.

  15. Randomized Controlled Ethanol Cookstove Intervention and Blood Pressure in Pregnant Nigerian Women.

    Science.gov (United States)

    Alexander, Donee; Northcross, Amanda; Wilson, Nathaniel; Dutta, Anindita; Pandya, Rishi; Ibigbami, Tope; Adu, Damilola; Olamijulo, John; Morhason-Bello, Oludare; Karrison, Theodore; Ojengbede, Oladosu; Olopade, Christopher O

    2017-06-15

    Hypertension during pregnancy is a leading cause of maternal mortality. Exposure to household air pollution elevates blood pressure (BP). To investigate the ability of a clean cookstove intervention to lower BP during pregnancy. We conducted a randomized controlled trial in Nigeria. Pregnant women cooking with kerosene or firewood were randomly assigned to an ethanol arm (n = 162) or a control arm (n = 162). BP measurements were taken during six antenatal visits. In the primary analysis, we compared ethanol users with control subjects. In subgroup analyses, we compared baseline kerosene users assigned to the intervention with kerosene control subjects and compared baseline firewood users assigned to ethanol with firewood control subjects. The change in diastolic blood pressure (DBP) over time was significantly different between ethanol users and control subjects (P = 0.040); systolic blood pressure (SBP) did not differ (P = 0.86). In subgroup analyses, there was no significant intervention effect for SBP; a significant difference for DBP (P = 0.031) existed among preintervention kerosene users. At the last visit, mean DBP was 2.8 mm Hg higher in control subjects than in ethanol users (3.6 mm Hg greater in control subjects than in ethanol users among preintervention kerosene users), and 6.4% of control subjects were hypertensive (SBP ≥140 and/or DBP ≥90 mm Hg) versus 1.9% of ethanol users (P = 0.051). Among preintervention kerosene users, 8.8% of control subjects were hypertensive compared with 1.8% of ethanol users (P = 0.029). To our knowledge, this is the first cookstove randomized controlled trial examining prenatal BP. Ethanol cookstoves have potential to reduce DBP and hypertension during pregnancy. Accordingly, clean cooking fuels may reduce adverse health impacts associated with household air pollution. Clinical trial registered with www.clinicaltrials.gov (NCT02394574).

  16. Effects of instant controlled pressure drop process on physical and sensory properties of puffed wheat snack.

    Science.gov (United States)

    Yağcı, Sibel

    2017-04-01

    In this study, research on the development of a puffed wheat snack using the instant controlled pressure drop (DIC) process was carried out. Snack products were produced by expanding moistened wheat under various DIC processing conditions in order to obtain adequate puffing, followed by drying in a hot air dryer. The effects of operational variables such as wheat initial moisture content (11-23% w/w, wet basis), processing pressure (3-5 × 10 2 kPa) and processing time (3-11 min) on the physical (density, color and textural characteristics) and sensory properties of the product were investigated. The physical properties of the wheat snack were most affected by changes in processing pressure, followed by processing time and wheat moisture content. Increasing processing pressure and time often improved expansion and textural properties but led to darkening of the raw wheat color. The most acceptable snack in terms of physical properties was obtained at the lowest wheat moisture content. Sensory analysis suggested that consumer acceptability was optimal for wheat snacks produced at higher processing pressure, medium processing time and lower moisture content. The most desirable conditions for puffed wheat snack production using the DIC process were determined as 11% (w/w) of wheat moisture content, 5 × 10 2 kPa of processing pressure and 7 min of processing time. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  17. Effect of Turkish classical music on blood pressure: a randomized controlled trial in hypertensive elderly patients.

    Science.gov (United States)

    Bekiroğlu, Tansel; Ovayolu, Nimet; Ergün, Yusuf; Ekerbiçer, Hasan Çetin

    2013-06-01

    Existing studies suggest that music therapy can have favorable effects on hypertension and anxiety. We therefore set out to investigate the effect of Turkish classical music. To investigate whether Turkish classical music has positive effects on blood pressures and anxiety levels in elderly patients. This was a randomized controlled trial performed on 60 hypertensive patients living in a local elderly home in Adana, Turkey. Following the completion of a socio-demographic form for each patient, Hamilton anxiety scale was applied. Thereafter, the subjects were randomly divided into two equal-size groups and were allowed to either listen to Turkish classical music (music therapy group) or have a resting period (control group) for 25 min. The primary and secondary outcome measures were blood pressure and Hamilton anxiety scale scores, respectively. The mean reduction in systolic blood pressure was 13.00 mmHg in the music therapy group and 6.50 mmHg in the control group. The baseline adjusted between treatment group difference was not statistically significant (95% CI 6.80-9.36). The median reductions in diastolic blood pressures were 10 mmHg both in the music therapy and control groups. The between treatment group difference was not statistically significant (Mann-Whitney U test, P = 0.839). The mean reduction in HAMA-A was 1.63 in the music therapy group and 0.77 in the control group. The baseline adjusted between treatment group difference was not statistically significant (95% CI 0.82-1.92). The study demonstrated that both Turkish classical music and resting alone have positive effects on blood pressure in patients with hypertension. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Using statistical process control for monitoring the prevalence of hospital-acquired pressure ulcers.

    Science.gov (United States)

    Kottner, Jan; Halfens, Ruud

    2010-05-01

    Institutionally acquired pressure ulcers are used as outcome indicators to assess the quality of pressure ulcer prevention programs. Determining whether quality improvement projects that aim to decrease the proportions of institutionally acquired pressure ulcers lead to real changes in clinical practice depends on the measurement method and statistical analysis used. To examine whether nosocomial pressure ulcer prevalence rates in hospitals in the Netherlands changed, a secondary data analysis using different statistical approaches was conducted of annual (1998-2008) nationwide nursing-sensitive health problem prevalence studies in the Netherlands. Institutions that participated regularly in all survey years were identified. Risk-adjusted nosocomial pressure ulcers prevalence rates, grade 2 to 4 (European Pressure Ulcer Advisory Panel system) were calculated per year and hospital. Descriptive statistics, chi-square trend tests, and P charts based on statistical process control (SPC) were applied and compared. Six of the 905 healthcare institutions participated in every survey year and 11,444 patients in these six hospitals were identified as being at risk for pressure ulcers. Prevalence rates per year ranged from 0.05 to 0.22. Chi-square trend tests revealed statistically significant downward trends in four hospitals but based on SPC methods, prevalence rates of five hospitals varied by chance only. Results of chi-square trend tests and SPC methods were not comparable, making it impossible to decide which approach is more appropriate. P charts provide more valuable information than single P values and are more helpful for monitoring institutional performance. Empirical evidence about the decrease of nosocomial pressure ulcer prevalence rates in the Netherlands is contradictory and limited.

  19. Study on Oil Pressure Characteristics and Trajectory Tracking Control in Shift Process of Wet-Clutch for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Junqiu Li

    2016-01-01

    Full Text Available Accurate control of oil pressure of wet-clutch is of great importance for improving shift quality. Based on dynamic models of two-gear planetary transmission and hydraulic control system, a trajectory tracking model of oil pressure was built by sliding mode control method. An experiment was designed to verify the validity of hydraulic control system, through which the relationship between duty cycle of on-off valve and oil pressure of clutch was determined. The tracking effect was analyzed by simulation. Results showed that oil pressure could follow well the optimal trajectory and the shift quality was effectively improved.

  20. Effects of voluntary and automatic control of center of pressure sway during quiet standing.

    Science.gov (United States)

    Ueta, Kozo; Okada, Yohei; Nakano, Hideki; Osumi, Michihiro; Morioka, Shu

    2015-01-01

    The authors investigated the effects of voluntary and automatic control on the spatial variables (envelope area, maximal amplitude, and root mean square [RMS]) of center of pressure (COP) displacement during quiet standing and identified differences in their postural control strategies (mean velocity [MV], mean power frequency [MPF], and power density). COP data were recorded under relaxed (experimental control), still (voluntary control), and dual (automatic control) conditions. RMS was significantly lower in the still and dual conditions than in the relaxed condition. MV, MPF, and power density were significantly higher in the still condition than in the dual condition. These results indicate that both voluntary and automatic control decrease the spatial variables of COP displacement; however, their postural control strategies are different.

  1. Pressure Control of a Pneumatic Actuator Using On/O Solenoid Valves

    OpenAIRE

    Jeddi Tehrani, Maisam

    2008-01-01

    Nowadays a very important aspect in heavy duty vehicles is the braking system. The braking system can be divided into EBS brakes, exhaust brake and retarder, where the latter is of interest in the present Master's Thesis. This thesis presents an investigation whether it is possible to substitute today's concept, i.e. controlling the air pressure to the retarder using a proportional-valve, with two so-called on/o®-valves and a pressure sensor, which will reduce expenses and contingently hyster...

  2. Performance analysis of a refrigeration system with parallel control of evaporation pressure

    International Nuclear Information System (INIS)

    Lee, Jong Suk

    2008-01-01

    The conventional refrigeration system is composed of a compressor, condenser, receiver, expansion valve or capillary tube, and an evaporator. The refrigeration system used in this study has additional expansion valve and evaporator along with an Evaporation Pressure Regulator(EPR) at the exit side of the evaporator. The two evaporators can be operated at different temperatures according to the opening of the EPR. The experimental results obtained using the refrigeration system with parallel control of evaporation pressure are presented and the performance analysis of the refrigeration system with two evaporators is conducted

  3. Self adaptive internal combustion engine control for hydrogen mixtures based on piezoelectric dynamic cylinder pressure transducers

    Energy Technology Data Exchange (ETDEWEB)

    Courteau, R.; Bose, T. K. [Universite du Quebec a Trois-Rivieres, Hydrogen Research Institute, Trois-Rivieres, PQ (Canada)

    2004-07-01

    An algorithm for self-adaptive tuning of an internal combustion engine is proposed, based on a Kalman filter operating on a few selected metrics of the dynamic pressure curve. Piezoelectric transducers are devices to monitor dynamic cylinder pressure; spark plugs with embedded piezo elements are now available to provide diagnostic engine functions. Such transducers are also capable of providing signals to the engine controller to perform auto tuning, a function that is considered very useful particularly in vehicles using alternative fuels whose characteristics frequently show variations between fill-ups. 2 refs., 2 figs.

  4. Theoretical basis of oxygen pressure control in liquid Pb-Bi using YSZ

    International Nuclear Information System (INIS)

    Jung, S. H.; Hwang, I. S.; Park, B. K.

    2002-01-01

    To develop a liquid Pb-Bi cooled reactor, it is necessary to solve the structural material corrosion problem caused by Pb-Bi. This experiment examine the fundamental behaviors to practically test the oxide film formation on the surface of structural material known as solution of corrosion inhibition in liquid Pb-Bi. The corrosion inhibition through oxide film formation is to prevent metals from dissolving into liquid Pb-Bi though not forming coolants slug resulted from oxidation. In this paper, we examined the oxygen pressure controllability using YSZ in cover gas, and theoretically derived the relationship between oxygen cover gas pressure and dissolved oxygen in liquid Pb-Bi

  5. Development and design of control rod drive mechanisms for pressurized water reactors

    International Nuclear Information System (INIS)

    Leme, Francisco Louzano

    2003-01-01

    The Control Rod Drive Mechanisms (CRDM) for a Pressurized Water Reactor (PWR) are equipment, integrated to the reactor pressure vessel, incorporating mechanical and electrical components designed to move and position the control rods to guarantee the control of power and shutdown of the nuclear reactor, during normal operation, either in emergency or accidental situations. The type of CRDM used in PWR reactors, whose detailed individual description will be presented in this monograph are the Roller-Nut and Magnetic-Jack. The environment, where the CRDM performs its above presented operational functions, includes direct contact with the fluid used as coolant peculiar to the interior of the reactor, and its associated chemical characteristics, the radiation field next to the reactor core, and also the temperature and pressure in the reactor pressure vessel. So the importance of the CRDM design requirements related to its safety functions are emphasized. Finally, some aspects related to the mechanical and structural design of CRDM of a case study, considering the CRDM for a PWR from the experimental nuclear plant to be applied by CTMSP (Centro Tecnologico da Marinha em Sao Paulo), are pointed out. The design and development of these equipment (author)

  6. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  7. Human factors assessment of conflict resolution aid reliability and time pressure in future air traffic control.

    Science.gov (United States)

    Trapsilawati, Fitri; Qu, Xingda; Wickens, Chris D; Chen, Chun-Hsien

    2015-01-01

    Though it has been reported that air traffic controllers' (ATCos') performance improves with the aid of a conflict resolution aid (CRA), the effects of imperfect automation on CRA are so far unknown. The main objective of this study was to examine the effects of imperfect automation on conflict resolution. Twelve students with ATC knowledge were instructed to complete ATC tasks in four CRA conditions including reliable, unreliable and high time pressure, unreliable and low time pressure, and manual conditions. Participants were able to resolve the designated conflicts more accurately and faster in the reliable versus unreliable CRA conditions. When comparing the unreliable CRA and manual conditions, unreliable CRA led to better conflict resolution performance and higher situation awareness. Surprisingly, high time pressure triggered better conflict resolution performance as compared to the low time pressure condition. The findings from the present study highlight the importance of CRA in future ATC operations. Practitioner Summary: Conflict resolution aid (CRA) is a proposed automation decision aid in air traffic control (ATC). It was found in the present study that CRA was able to promote air traffic controllers' performance even when it was not perfectly reliable. These findings highlight the importance of CRA in future ATC operations.

  8. Dynamic plantar pressure distribution, strength capacity and postural control after Lisfranc fracture-dislocation

    DEFF Research Database (Denmark)

    Mehlhorn, Alexander T; Walther, Markus; Yilmaz, Tayfun

    2017-01-01

    of life. 17 consecutive patients suffering from a Lisfranc fracture dislocation were registered, underwent open reduction and internal fixation and were followed-up for 50.5±25.7months (Mean±SDM). Biomechanical analysis of muscle strength capacities, postural control and plantar pressure distribution......Substantial progress has been made in the operative treatment of Lisfranc fractures, however, the prognosis remains poor. We hypothesized that Lisfranc injuries change the postural control and muscle strength of the lower limb. Both are suggested to correlate with the clinical outcome and quality...... correlated well with clinical outcome. Altered postural control was evident by a significant reduction in unilateral stance time, from which we calculated a strong correlation between stance time and the isokinetic strength measurement. Plantar pressure measurements revealed a significant reduction in peak...

  9. Safety of 5 MW district heating reactor (DHR) and hydraulic dynamic pressure drive control rods

    International Nuclear Information System (INIS)

    Wu Yuanqiang; Wang Dazhong

    1991-11-01

    The principles and movement characteristic of the hydraulic dynamic pressure drive for control rods in 5 MW district heating reactor are described with stress on analysis of its effects on reactor safety features. The drive is different from electric-magnetic drive for PWR or hydraulic drive for BWR. The drive cylinder is driven by dynamic pressure. In the new drive system, the reactor coolant (water) used as actuating medium is pressed by pump, then injected into a step cylinder which is set in the reactor core. The cylinder will move step by step by controlling flow, then the cylinder drives the neutron absorber and controls nuclear reaction. The drive is characterized by simplicity in structure, high reliability, inherent safety, reduction in reactor height, economy, etc

  10. Estimation of excitation forces for wave energy converters control using pressure measurements

    Science.gov (United States)

    Abdelkhalik, O.; Zou, S.; Robinett, R.; Bacelli, G.; Wilson, D.

    2017-08-01

    Most control algorithms of wave energy converters require prediction of wave elevation or excitation force for a short future horizon, to compute the control in an optimal sense. This paper presents an approach that requires the estimation of the excitation force and its derivatives at present time with no need for prediction. An extended Kalman filter is implemented to estimate the excitation force. The measurements in this approach are selected to be the pressures at discrete points on the buoy surface, in addition to the buoy heave position. The pressures on the buoy surface are more directly related to the excitation force on the buoy as opposed to wave elevation in front of the buoy. These pressure measurements are also more accurate and easier to obtain. A singular arc control is implemented to compute the steady-state control using the estimated excitation force. The estimated excitation force is expressed in the Laplace domain and substituted in the control, before the latter is transformed to the time domain. Numerical simulations are presented for a Bretschneider wave case study.

  11. Flow Control Device Evaluation for an Internal Flow with an Adverse Pressure Gradient

    Science.gov (United States)

    Jenkins, Luther N.; Gorton, Susan Althoff; Anders, Scott G.

    2002-01-01

    The effectiveness of several active and passive devices to control flow in an adverse pressure gradient with secondary flows present was evaluated in the 15 Inch Low Speed Tunnel at NASA Langley Research Center. In this study, passive micro vortex generators, micro bumps, and piezoelectric synthetic jets were evaluated for their flow control characteristics using surface static pressures, flow visualization, and 3D Stereo Digital Particle Image Velocimetry. Data also were acquired for synthetic jet actuators in a zero flow environment. It was found that the micro vortex generator is very effective in controlling the flow environment for an adverse pressure gradient, even in the presence of secondary vortical flow. The mechanism by which the control is effected is a re-energization of the boundary layer through flow mixing. The piezoelectric synthetic jet actuators must have sufficient velocity output to produce strong longitudinal vortices if they are to be effective for flow control. The output of these devices in a laboratory or zero flow environment will be different than the output in a flow environment. In this investigation, the output was higher in the flow environment, but the stroke cycle in the flow did not indicate a positive inflow into the synthetic jet.

  12. An analytical investigation on the valve and centrifugal pump speed control with a constant differential pressure across the valve

    International Nuclear Information System (INIS)

    Jung, B. R.; Joo, K. I.; Lee, B. J.; Baek, S. J.; Noh, T. S.

    2003-01-01

    A valve opening and centrifugal pump speed control was investigated analytically in a simple pumping system where the differential pressure across the control valve is maintained constant over the required flow range. The valve control program was derived analytically only as a function of the required flow rate to maintain the constant differential pressure across the valve. The centrifugal pump speed control program was also derived analytically for the required flow rate for the constant differential pressure across the control valve. These derivations theoretically show that the independent control is possible between the valve and pump speed in a system with a constant valve pressure drop. In addition, it was shown that a linear pump speed control is impossible in maintaining the constant valve pressure drop

  13. Renovating process for Pressurized Water Reactor control rod assemblies and corresponding control

    International Nuclear Information System (INIS)

    Jahnke, S.; Ple, P.

    1989-01-01

    In the first PWRs the control rods are moving by the intermediary of electromagnetic mechanisms where the power fed to the electromagnets is selected by a hard wired logic circuit connected to the controldesh by another logic control. For renovating the control rod assemblies each power assembly is replaced by an electronic assembly containing an ordinator and power supply interfaces [fr

  14. Structural Metadata Research in the Ears Program

    National Research Council Canada - National Science Library

    Liu, Yang; Shriberg, Elizabeth; Stolcke, Andreas; Peskin, Barbara; Ang, Jeremy; Hillard, Dustin; Ostendorf, Mari; Tomalin, Marcus; Woodland, Phil; Harper, Mary

    2005-01-01

    Both human and automatic processing of speech require recognition of more than just words. In this paper we provide a brief overview of research on structural metadata extraction in the DARPA EARS rich transcription program...

  15. Mozart ear: diagnosis, treatment, and literature review.

    Science.gov (United States)

    Yamashita, Ken; Yotsuyanagi, Takatoshi; Saito, Tamotsu; Isogai, Noritaka; Mori, Hiromasa; Itani, Yoshihito

    2011-11-01

    Mozart ear is a congenital auricular deformity, which is mainly characterized by a bulging appearance of the anterosuperior portion of the auricle, a convexly protruded cavum conchae, and a slit-like narrowing of the orifice of the external auditory meatus. It is said to be uncommon, and because no one has yet fully described neither the disease nor the treatment, the concept of Mozart ear has not been unified. This report describes a case of a 13-year-old girl presented with an unusual congenital deformity which showed the features of Mozart ear. It is an extremely rare deformity that only about 4 clinical cases have been reported in medical literature thereby a treatment method has not been fully discussed. For surgical correction of our cases, we excised deformed conchal cartilage, turned it over, regrafted, and maintained a cosmetically positive result. We also reviewed and described the origin, current concept, and treatment method of Mozart ear.

  16. Environment for Auditory Research Facility (EAR)

    Data.gov (United States)

    Federal Laboratory Consortium — EAR is an auditory perception and communication research center enabling state-of-the-art simulation of various indoor and outdoor acoustic environments. The heart...

  17. Organizational Leadership and Adaptive Reserve in Blood Pressure Control: The Heart Health NOW Study.

    Science.gov (United States)

    Henderson, Kamal H; DeWalt, Darren A; Halladay, Jacquie; Weiner, Bryan J; Kim, Jung I; Fine, Jason; Cykert, Samuel

    2018-04-01

    Our purpose was to assess whether a practice's adaptive reserve and high leadership capability in quality improvement are associated with population blood pressure control. We divided practices into quartiles of blood pressure control performance and considered the top quartile as the benchmark for comparison. Using abstracted clinical data from electronic health records, we performed a cross-sectional study to assess the association of top quartile hypertension control and (1) the baseline practice adaptive reserve (PAR) scores and (2) baseline practice leadership scores, using modified Poisson regression models adjusting for practice-level characteristics. Among 181 practices, 46 were in the top quartile, which averaged 68% or better blood pressure control. Practices with higher PAR scores compared with lower PAR scores were not more likely to reside in the top quartile of performance (prevalence ratio [PR] = 1.92 for highest quartile; 95% CI, 0.9-4.1). Similarly, high quality improvement leadership capability compared with lower capability did not predict better blood pressure control performance (PR = 0.94; 95% CI, 0.57-1.56). Practices with higher proportions of commercially insured patients were more likely than practices with lower proportions of commercially insured patients to have top quartile performance (37% vs 26%, P =.002), whereas lower proportions of the uninsured (8% vs 14%, P =.055) were associated with better performance. Our findings show that adaptive reserve and leadership capability in quality improvement implementation are not statistically associated with achieving top quartile practice-level hypertension control at baseline in the Heart Health NOW project. Our findings, however, may be limited by a lack of patient-related factors and small sample size to preclude strong conclusions. © 2018 Annals of Family Medicine, Inc.

  18. Intra-oral pressure-based voicing control of electrolaryngeal speech with intra-oral vibrator.

    Science.gov (United States)

    Takahashi, Hirokazu; Nakao, Masayuki; Kikuchi, Yataro; Kaga, Kimitaka

    2008-07-01

    In normal speech, coordinated activities of intrinsic laryngeal muscles suspend a glottal sound at utterance of voiceless consonants, automatically realizing a voicing control. In electrolaryngeal speech, however, the lack of voicing control is one of the causes of unclear voice, voiceless consonants tending to be misheard as the corresponding voiced consonants. In the present work, we developed an intra-oral vibrator with an intra-oral pressure sensor that detected utterance of voiceless phonemes during the intra-oral electrolaryngeal speech, and demonstrated that an intra-oral pressure-based voicing control could improve the intelligibility of the speech. The test voices were obtained from one electrolaryngeal speaker and one normal speaker. We first investigated on the speech analysis software how a voice onset time (VOT) and first formant (F1) transition of the test consonant-vowel syllables contributed to voiceless/voiced contrasts, and developed an adequate voicing control strategy. We then compared the intelligibility of consonant-vowel syllables among the intra-oral electrolaryngeal speech with and without online voicing control. The increase of intra-oral pressure, typically with a peak ranging from 10 to 50 gf/cm2, could reliably identify utterance of voiceless consonants. The speech analysis and intelligibility test then demonstrated that a short VOT caused the misidentification of the voiced consonants due to a clear F1 transition. Finally, taking these results together, the online voicing control, which suspended the prosthetic tone while the intra-oral pressure exceeded 2.5 gf/cm2 and during the 35 milliseconds that followed, proved efficient to improve the voiceless/voiced contrast.

  19. Effects of motherwort alkaloids on rat ear acne

    Directory of Open Access Journals (Sweden)

    Miao Mingsan

    2016-04-01

    Full Text Available The aim of this study was to explore the effects of motherwort alkaloids on rat ear acne. The rats that were administered high, medium, and low doses of motherwort alkaloids, tanshinone capsules, a model and a control group. Each group of rats was subjected to gavage once daily for 14 consecutive days. On the first day of testing, the control and model groups were administered an intradermal auricle injection of sterilized saline solution and the remaining groups were administered an intradermal auricle injection of Staphylococcus epidermidis in addition to the gavage. The thicknesses of the rats’ auricles were measured for five consecutive days following the injections. Anticoagulated blood was used for erythrocyte rheology index measurement. In addition, the entire ear of each rat was removed for morphological examination. Compared to the model group, the group administered motherwort alkaloids exhibited significantly reduced swelling, improved localized auricle proliferation, and reduced blood viscosity. This result suggests motherwort alkaloids are effective in rat ear acne.

  20. Pressure fluctuation analysis for charging pump of chemical and volume control system of nuclear power plant

    Directory of Open Access Journals (Sweden)

    Chen Qiang

    2016-01-01

    Full Text Available Equipment Failure Root Cause Analysis (ERCA methodology is employed in this paper to investigate the root cause for charging pump’s pressure fluctuation of chemical and volume control system (RCV in pressurized water reactor (PWR nuclear power plant. RCA project task group has been set up at the beginning of the analysis process. The possible failure modes are listed according to the characteristics of charging pump’s actual pressure fluctuation and maintenance experience during the analysis process. And the failure modes are analysed in proper sequence by the evidence-collecting. It suggests that the gradually untightened and loosed shaft nut in service should be the root cause. And corresponding corrective actions are put forward in details.

  1. KATP channels are not essential for pressure-dependent control of renin secretion

    DEFF Research Database (Denmark)

    Jensen, B L; Gambaryan, S; Scholz, H

    1998-01-01

    (IPRK). Cromakalim (0.1-10 muM) stimulated basal renin secretion up to threefold and caused vasorelaxation in the IPRK. Both effects of cromakalim were attenuated by glibenclamide. Cromakalim stimulated renin secretion from isolated juxtaglomerular (JG) cells and from microdissected afferent arterioles......This study aimed to investigate the functional role of ATP-sensitive K+ (KATP) channels in the control of renin secretion by renal perfusion pressure. We studied the effect of openers and blockers of KATP-channels on basal- and low-pressure-induced renin secretion from isolated perfused rat kidneys......, all of which suggests that KATP channel openers stimulate renin secretion at the level of JG cells. A decrease in the perfusion pressure from 13.3 to 9.33 kPa (100 mmHg to 70 mmHg) increased renin secretion twofold, and cromakalim further increased renin secretion. At 5.33 kPa (40 mmHg) renin...

  2. Pressure controlled transition into a self-induced topological superconducting surface state

    KAUST Repository

    Zhu, Zhiyong; Cheng, Yingchun; Schwingenschlö gl, Udo

    2014-01-01

    Ab-initio calculations show a pressure induced trivial-nontrivial-trivial topological phase transition in the normal state of 1T-TiSe2. The pressure range in which the nontrivial phase emerges overlaps with that of the superconducting ground state. Thus, topological superconductivity can be induced in protected surface states by the proximity effect of superconducting bulk states. This kind of self-induced topological surface superconductivity is promising for a realization of Majorana fermions due to the absence of lattice and chemical potential mismatches. For appropriate electron doping, the formation of the topological superconducting surface state in 1T-TiSe 2 becomes accessible to experiments as it can be controlled by pressure.

  3. Self adaptive internal combustion engine control for hydrogen mixtures based on piezoelectric dynamic cylinder pressure transducers

    International Nuclear Information System (INIS)

    Courteau, R.; Bose, T.K.

    2004-01-01

    Piezoelectric transducers offer an effective, non-intrusive way to monitor dynamic cylinder pressure in internal combustion engines. Devices dedicated to this purpose are appearing on the market, often in the form of spark plugs with embedded piezo elements. Dynamic cylinder pressure is typically used to provide diagnostic functions, or to help map an engine after it is designed. With the advent of powerful signal processor chips, it is now possible to embed enough computing power in the engine controller to perform auto tuning based on the signals provided by such transducers. Such functionality is very useful if the fuel characteristics vary between fill ups, as is often the case with alternative fuels. We propose here an algorithm for self-adaptive tuning based on a Kalman filter operating on a few selected metrics of the dynamic pressure curve. (author)

  4. Pressure controlled transition into a self-induced topological superconducting surface state

    KAUST Repository

    Zhu, Zhiyong

    2014-02-07

    Ab-initio calculations show a pressure induced trivial-nontrivial-trivial topological phase transition in the normal state of 1T-TiSe2. The pressure range in which the nontrivial phase emerges overlaps with that of the superconducting ground state. Thus, topological superconductivity can be induced in protected surface states by the proximity effect of superconducting bulk states. This kind of self-induced topological surface superconductivity is promising for a realization of Majorana fermions due to the absence of lattice and chemical potential mismatches. For appropriate electron doping, the formation of the topological superconducting surface state in 1T-TiSe 2 becomes accessible to experiments as it can be controlled by pressure.

  5. Thermoplastic fusion bonding using a pressure-assisted boiling point control system.

    Science.gov (United States)

    Park, Taehyun; Song, In-Hyouk; Park, Daniel S; You, Byoung Hee; Murphy, Michael C

    2012-08-21

    A novel thermoplastic fusion bonding method using a pressure-assisted boiling point (PABP) control system was developed to apply precise temperatures and pressures during bonding. Hot embossed polymethyl methacrylate (PMMA) components containing microchannels were sealed using the PABP system. Very low aspect ratio structures (AR = 1/100, 10 μm in depth and 1000 μm in width) were successfully sealed without collapse or deformation. The integrity and strength of the bonds on the sealed PMMA devices were evaluated using leakage and rupture tests; no leaks were detected and failure during the rupture tests occurred at pressures greater than 496 kPa. The PABP system was used to seal 3D shaped flexible PMMA devices successfully.

  6. Verrucous carcinoma of the middle ear.

    Science.gov (United States)

    Woodson, G E; Jurco, S; Alford, B R; McGavran, M H

    1981-01-01

    A case of a highly destructive, cytologically nondysplastic squamous epithelial lesion of the middle ear is presented. The cranial nerve involvement and bone destruction are more extensive than has been seen in cholesteatoma. Cultures are negative for Pseudomonas, and the patient does not have the reported diathesis for malignant otitis externa. The gross and microscopic features are those of verrucous carcinoma. To our knowledge, the middle ear has not been previously reported as a site of involvement by verrucous carcinoma.

  7. Osteoma of the middle ear: case report

    International Nuclear Information System (INIS)

    Ryu, Ji Hwa

    2005-01-01

    Osteomas of the middle ear are exceedingly rare benign neoplasms. To date, only 21 cases have been reported in the literature. They arise from the promontory, the pyramidal process and the ossicles, and they are usually asymptomatic or cause some conductive hearing loss. We report here the CT and pathologic findings in a 38-year-old woman with a benign osteoma of the middle ear along with chronic otitis media

  8. Commissioning of n_TOF EAR2

    CERN Multimedia

    The construction of the second beam line and experiment area (EAR2) of the n_TOF facility is currently ongoing and scheduled to be completed by July 2014. An extensive series of measurements is planned in order to determine the beam characteristics like the neutron flux, the spatial beam profile and the resolution function, as well as the response of several detectors considered for use in future measurements at EAR2. A rigorous study of backgrounds will be undertaken in various conditions.

  9. Osteoma of the middle ear: case report

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Ji Hwa [College of Medicine, Inje University, Dongrae Paik Hospital, Busan (Korea, Republic of)

    2005-07-15

    Osteomas of the middle ear are exceedingly rare benign neoplasms. To date, only 21 cases have been reported in the literature. They arise from the promontory, the pyramidal process and the ossicles, and they are usually asymptomatic or cause some conductive hearing loss. We report here the CT and pathologic findings in a 38-year-old woman with a benign osteoma of the middle ear along with chronic otitis media.

  10. Optimal control of load-following operations in a pressurized water reactor

    International Nuclear Information System (INIS)

    Zhao Fuyu; Zhou Dawei

    2000-01-01

    According to the optimal control theory, the problem of load-following operation in a pressurized water reactor is formulated as a nonlinear-quadratic optimal control problem. One-dimensional core model is adopted. A successful optimization algorithm DDPSR is proposed to solving the obtained problem. The research results show that the DDPSR can converge with a long time interval and needs very small iteration number and computing time, and the practical reactor can be fairly operated in an optimal load-following manner and axial offset satisfies the required value from beginning to end. Control characters of boron concentration are discussed specially

  11. Modeling of boron control during power transients in a pressurized water reactor

    International Nuclear Information System (INIS)

    Mathieu, P.; Distexhe, E.

    1986-01-01

    Accurate control instructions in a reactor control aid computer are included in order to realize the boron makeup throughput, which is required to obtain the boron concentration in the primary coolant loop, predicted by a neutronic code. A modeling of the transfer function between the makeup and the primary loop is proposed. The chemical and volumetric control system, the pressurizer, and the primary loop are modeled as instantaneous diffusion cells. The pipes are modeled as time lag lines. The model provides the unstationary boron distributions in the different elements of the setup. A numerical code is developed to calculate the time evolutions of the makeup throughput during power transients

  12. Technical specifications of variable speed motors for negative pressure control in hot cell area

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Duk; Bang, H. S.; Cho, W. K

    2002-01-01

    Hot cells are the facilities for handling the high radioactive materials and various R and D activities are performed using hot cells. Therefore the control of air flow in hot cell area is very important technology and it is started with the variable speed motor(VSM) controlling the air handling system in that area. This report describes various technical aspects of VS motors and will be useful for understanding the practical technologies of VS motors and also for optimization of the negative pressure controls in hot cell area.

  13. Fuzzy logic control of steam generator water level in pressurized water reactors

    International Nuclear Information System (INIS)

    Kuan, C.C.; Lin, C.; Hsu, C.C.

    1992-01-01

    In this paper a fuzzy logic controller is applied to control the steam generator water level in a pressurized water reactor. The method does not require a detailed mathematical mode of the object to be controlled. The design is based on a set of linguistic rules that were adopted from the human operator's experience. After off-line fuzzy computation, the controller is a lookup table, and thus, real-time control is achieved. Shrink-and-swell phenomena are considered in the linguistic rules, and the simulation results show that their effect is dramatically reduced. The performance of the control system can also be improved by changing the input and output scaling factors, which is convenient for on-line tuning

  14. Scram characteristics of the control rods of a pressurized water reactor under seismic conditions

    International Nuclear Information System (INIS)

    Fujita, Katsuhisa; Shinohara, Yoshikazu; Nakatogawa, Tetsuto; Nanbu, Kiyoshi; Nomura, Tomonori.

    1987-01-01

    Control rod drop verification experiments of a pressurized water reactor under seismic conditions are performed to confirm the insertion function of control rods into a core. To evaluate these tests, computer simulations are performed. A fuel assembly, control rods, guide tube and other associated structures are immersed in a water tank, and shaken by four hydraulic shakers. The scram time of control rods under seismic conditions was measured, and confirmed to meet the scram function. Moreover, vibrational response characteristics of core structures and dropping behavior of control rods in consideration of collisions are calculated by using a finite difference method. The behavior of the dropping control rods and the scram time obtained by the computer simulation show a very good agreement with the verification experimental results. (author)

  15. Effect of mechanical pressure-controlled ventilation in patients with disturbed respiratory function during laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    Šurbatović Maja

    2013-01-01

    Full Text Available Background/Aim: Laparoscopic cholecystectomy is considered to be the gold standard for laparoscopic surgical procedures. In ASA III patients with concomitant respiratory diseases, however, creation of pneumoperitoneum and the position of patients during surgery exert additional negative effect on intraoperative respiratory function, thus making a higher challenge for the anesthesiologist than for the surgeon. The aim of this study was to compare the effect of intermittent positive pressure ventilation (IPPV and pressure controlled ventilation (PCV during general anesthesia on respiratory function in ASA III patients submitted to laparoscopic cholecystectomy. Methods. The study included 60 patients randomized into two groups depending on the mode of ventilation: IPPV or PCV. Respiratory volume (VT, peak inspiratory pressure (PIP, compliance (C, end-tidal CO2 pressure (PETCO2, oxygen saturation (SpO2, partial pressures of O2, CO2 (PaO2 and PaCO2 and pH of arterial blood were recorded within four time intervals. Results. There were no statistically significant differences in VT, SpO2, PaO2, PaCO2 and pH values neither within nor between the two groups. In time interval t1 there were no statistically significant differences in PIP, C, PETCO2 values between the IPPV and the PCV group. But, in the next three time intervals there was a difference in PIP, C, and PETCO2 values between the two groups which ranged from statistically significant to highly significant; PIP was lower, C and PETCO2 were higher in the PCV group. Conclusion. Pressure controlled ventilation better maintains stability regarding intraoperative ventilatory parameters in ASA III patients with concomitant respiratory diseases during laparoscopic cholecystectomy.

  16. Pore pressure control on faulting behavior in a block-gouge system

    Science.gov (United States)

    Yang, Z.; Juanes, R.

    2016-12-01

    Pore fluid pressure in a fault zone can be altered by natural processes (e.g., mineral dehydration and thermal pressurization) and industrial operations involving subsurface fluid injection/extraction for the development of energy and water resources. However, the effect of pore pressure change on the stability and slip motion of a preexisting geologic fault remain poorly understood; yet they are critical for the assessment of seismic risk. In this work, we develop a micromechanical model to investigate the effect of pore pressure on faulting behavior. The model couples pore network fluid flow and mechanics of the solid grains. We conceptualize the fault zone as a gouge layer sandwiched between two blocks; the block material is represented by a group of contact-bonded grains and the gouge is composed of unbonded grains. A pore network is extracted from the particulate pack of the block-gouge system with pore body volumes and pore throat conductivities calculated rigorously based on the geometry of the local pore space. Pore fluid exerts pressure force onto the grains, the motion of which is solved using the discrete element method (DEM). The model updates the pore network regularly in response to deformation of the solid matrix. We study the fault stability in the presence of a pressure inhomogeneity (gradient) across the gouge layer, and compare it with the case of homogeneous pore pressure. We consider both normal and thrust faulting scenarios with a focus on the onset of shear failure along the block-gouge interfaces. Numerical simulations show that the slip behavior is characterized by intermittent dynamics, which is evident in the number of slipping contacts at the block-gouge interfaces and the total kinetic energy of the gouge particles. Numerical results also show that, for the case of pressure inhomogeneity, the onset of slip occurs earlier for the side with higher pressure, and that this onset appears to be controlled by the maximum pressure of both sides

  17. Control-rod, pressure and flow-induced accident and transient analysis of a direct-cycle, supercritical-pressure, light-water-cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Kitoh, Kazuaki; Koshizuka, Seiichi; Oka, Yoshiaki

    1996-01-01

    The features of the direct-cycle, supercritical-pressure, light-water-cooled fast breeder reactor (SCFBR) are high thermal efficiency and simple reactor system. The safety principle is basically the same as that of an LWR since it is a water-cooled reactor. Maintaining the core flow is the basic safety requirement of the reactor, since its coolant system is the one through type. The transient behaviors at control rod, pressure and flow-induced abnormalities are analyzed and presented in this paper. The results of flow-induced transients of SCFBR were reported at ICONE-3, though pressure change was neglected. The change of fuel temperature distribution is also considered for the analysis of the rapid reactivity-induced transients such as control rod withdrawal. Total loss of flow and pump seizure are analyzed as the accidents. Loss of load, control rod withdrawal from the normal operation, loss of feedwater heating, inadvertent start of an auxiliary feedwater pump, partial loss of coolant flow and loss of external power are analyzed as the transients. The behavior of the flow-induced transients is not so much different from the analyses assuming constant pressure. Fly wheels should be equipped with the feedwater pumps to prolong the coast-down time more than 10s and to cope with the total loss of flow accident. The coolant density coefficient of the SCFBR is less than one tenth of a BWR in which the recirculation flow is used for the power control. The over pressurization transients at the loss of load is not so severe as that of a BWR. The power reaches 120%. The minimum deterioration heat flux ratio (MDHFR) and the maximum pressure are sufficiently lower than the criteria; MDHFR above 1.0 and pressure ratio below 1.10 of 27.5 MPa, maximum pressure for operation. Among the reactivity abnormalities, the control rod withdrawal transient from the normal operation is analyzed

  18. Determination of pressure distribution in an aerated bed in a controlled pilot-scale compost reactor

    Energy Technology Data Exchange (ETDEWEB)

    Solowiej, P. [Warmia and Mazury Univ., Olsztyn (Poland)

    2010-07-01

    This study investigated the effectiveness of dealing with biological waste by composting. In particular, it examined the feasibility of recovering excess thermal energy produced in the process of composting biological waste in terms of mass and energy transport parameters required in the aerated compost bed. An experiment was performed in which a 100 dm{sup 3} adiabatic, leak-tight reactor equipped with a controlled aeration system was constructed to study the temperature and pressure distribution in the bed. Sensors were used to determine the amount and humidity of emitted gases under variable external physical conditions. The perforated bottom of the reactor allowed for bed aeration. As such, the humidity and heat were transported upwards, forced by the air pumped in and by natural convection. In terms of pressure distribution inside the composted and aerated bed, the study results showed that there were considerable differences in pressure for the selected places of the bed of the composted biological material. An increase in upwards pressure was observed in the heap throughout the experiment. Pressure differences in the same plane of the bed were also noted. The study results should facilitate the development of a model of mass and energy transport in a bed of composted material.

  19. Evaluation of pressure response in the Los Alamos controlled air incinerator during three incident scenarios

    International Nuclear Information System (INIS)

    Vavruska, J.S.; Elsberry, K.; Thompson, T.K.; Pendergrass, J.A.

    1996-01-01

    The Los Alamos Controlled Air Incinerator (CAI) is a system designed to accept radioactive mixed waste containing alpha-emitting radionuclides. A mathematical model was developed to predict the pressure response throughout the offgas treatment system of the CAI during three hypothetical incident scenarios. The scenarios examined included: (1) loss of burner flame and failure of the flame safeguard system with subsequent reignition of fuel gas in the primary chamber, (2) pyrolytic gas buildup from a waste package due to loss of induced draft and subsequent restoration of induced draft, and (3) accidental charging of propellant spray cans in a solid waste package to the primary chamber during a normal feed cycle. For each of the three scenarios, the finite element computer model was able to determine the transient pressure surge and decay response throughout the system. Of particular interest were the maximum absolute pressures attainable at critical points in the system as well as maximum differential pressures across the high efficiency particulate air (HEPA) filters. Modeling results indicated that all three of the scenarios resulted in maximum HEPA filter differential pressures well below the maximum allowable levels

  20. Developing an optimal valve closing rule curve for real-time pressure control in pipes

    Energy Technology Data Exchange (ETDEWEB)

    Bazarganlari, Mohammad Reza; Afshar, Hossein [Islamic Azad University, Tehran (Iran, Islamic Republic of); Kerachian, Reza [University of Tehran, Tehran (Iran, Islamic Republic of); Bashiazghadi, Seyyed Nasser [Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2013-01-15

    Sudden valve closure in pipeline systems can cause high pressures that may lead to serious damages. Using an optimal valve closing rule can play an important role in managing extreme pressures in sudden valve closure. In this paper, an optimal closing rule curve is developed using a multi-objective optimization model and Bayesian networks (BNs) for controlling water pressure in valve closure instead of traditional step functions or single linear functions. The method of characteristics is used to simulate transient flow caused by valve closure. Non-dominated sorting genetic algorithms-II is also used to develop a Pareto front among three objectives related to maximum and minimum water pressures, and the amount of water passes through the valve during the valve-closing process. Simulation and optimization processes are usually time-consuming, thus results of the optimization model are used for training the BN. The trained BN is capable of determining optimal real-time closing rules without running costly simulation and optimization models. To demonstrate its efficiency, the proposed methodology is applied to a reservoir-pipe-valve system and the optimal closing rule curve is calculated for the valve. The results of the linear and BN-based valve closure rules show that the latter can significantly reduce the range of variations in water hammer pressures.

  1. Prevalence and control of high blood pressure in primary care: results from the German Metabolic and Cardiovascular Risk Study (GEMCAS).

    Science.gov (United States)

    Balijepalli, Chakrapani; Bramlage, Peter; Lösch, Christian; Zemmrich, Claudia; Humphries, Karin H; Moebus, Susanne

    2014-06-01

    Contemporary epidemiological data on blood pressure readings, hypertension prevalence and control in unselected patient populations covering a broad age range are scarce. The aim here is to report the prevalence of high blood pressure and to identify factors associated with blood pressure control in a large German primary care sample. We used data from the German Metabolic and Cardiovascular Risk Study including 35 869 patients aged 18-99 years. High blood pressure was defined as systolic blood pressure ≥140 mm Hg and/or diastolic blood pressure ≥90 mm Hg or using antihypertensive therapy. Factors associated with blood pressure control among patients receiving antihypertensive therapy were examined using multiple logistic regressions to estimate odds ratios and 95% confidence intervals. The prevalence of high blood pressure, uncontrolled high blood pressure and untreated high blood pressure was 54.8%, 21.3% and 17.6%, respectively. Age >50 years (1.52; 1.40-1.65), male sex (1.30; 1.20-1.41), elevated waist circumference (1.55; 1.45-1.65), high cholesterol (1.24; 1.16-1.33), high triglycerides (1.11; 1.04-1.19) and concomitant diabetes (1.29; 1.20-1.40) were independently associated with uncontrolled high blood pressure. In a majority of patients we observed hypertension despite treatment for high blood pressures. Studies examining the reasons for treatment failure are highly warranted.

  2. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation.

    Science.gov (United States)

    Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham

    2014-08-01

    To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (prights reserved.

  3. Micro-controller based air pressure monitoring instrumentation system using optical fibers as sensor

    Science.gov (United States)

    Hazarika, D.; Pegu, D. S.

    2013-03-01

    This paper describes a micro-controller based instrumentation system to monitor air pressure using optical fiber sensors. The principle of macrobending is used to develop the sensor system. The instrumentation system consists of a laser source, a beam splitter, two multi mode optical fibers, two Light Dependent Resistance (LDR) based timer circuits and a AT89S8252 micro-controller. The beam splitter is used to divide the laser beam into two parts and then these two beams are launched into two multi mode fibers. One of the multi mode fibers is used as the sensor fiber and the other one is used as the reference fiber. The use of the reference fiber is to eliminate the environmental effects while measuring the air pressure magnitude. The laser beams from the sensor and reference fibers are applied to two identical LDR based timer circuits. The LDR based timer circuits are interfaced to a micro-controller through its counter pins. The micro-controller samples the frequencies of the timer circuits using its counter-0 and counter-1 and the counter values are then processed to provide the measure of air pressure magnitude.

  4. Serous otitis media (S.O.M.). A bacteriological study of the ear canal and the middle ear

    NARCIS (Netherlands)

    Cabenda, S. I.; Peerbooms, P. G.; van Asselt, G. J.; Feenstra, L.; van der Baan, S.

    1988-01-01

    A bacteriological study of the middle-ear effusions and the ear canals in children with chronic serous otitis media (S.O.M.) was performed. Sixty-eight children (127 ears) were investigated. From this study it appeared that cleansing of the ear canal with 0.5% chlorhexidine in 70% ethanol for 30 s

  5. Ear-to-Ear On-Body Channel Fading in the ISM-band for Tangentially-Polarized Antennas

    DEFF Research Database (Denmark)

    Kvist, Søren Helstrup; Thaysen, Jesper; Jakobsen, Kaj Bjarne

    2011-01-01

    The ear-to-ear on-body channel fading has been studied in the ISM-band. The ear-to-ear path gain was measured on six persons in an indoor environment for a duration of 200 s. The channel fading has been characterized in terms of empirical cumulative distribution functions (CDF), average fade...

  6. Statistical Shape Analysis of the Human Ear Canal with Application to In-the-Ear Hearing Aid Design

    DEFF Research Database (Denmark)

    Paulsen, Rasmus Reinhold

    2004-01-01

    This thesis is about the statistical shape analysis of the human ear canal with application to the mechanical design of in-the-ear hearing aids. Initially, it is described how a statistical shape model of the human ear canal is built based on a training set of laser-scanned ear impressions. A thin...

  7. Selective formation of VO2(A) or VO2(R) polymorph by controlling the hydrothermal pressure

    International Nuclear Information System (INIS)

    Ji Shidong; Zhang Feng; Jin Ping

    2011-01-01

    Missing VO 2 (A) usually occurs during the preparation of VO 2 polymorphs. This leads to an ambiguous understanding of the transformation between VO 2 polymorphs. The calculation of the ground state energies for different VO 2 polymorphs indicated that there is only a small energy gap between VO 2 (A) and VO 2 (R), which destined that the transformation from VO 2 (A) to VO 2 (R) should be pressure sensitive. This hypothesis was verified during the synthesizing of VO 2 polymorphs by reducing V 2 O 5 with oxalic acid through hydrothermal treatment process. Selective formation of pure phase VO 2 (A) or VO 2 (R) was achieved by controlling the hydrothermal pressure through varying the filling ratio at 270 deg. C. It was found that a filling ratio over 0.5 favors the formation of pure VO 2 (R) while a reduced filling ratio to 0.4 or lower results in the formation of VO 2 (A). Based on our experiments, VO 2 (B) nanobelts were always first formed and then it transformed to VO 2 (A) by assembling process at increased temperature or extended reaction time. Under further higher pressure, the VO 2 (A) transformed spontaneously to VO 2 (R) initialized from the volume shrinkage due to the formation of denser VO 2 (R). - Graphical abstract: Selective formation of VO 2 (A) or VO 2 (R) could be achieved by controlling the system pressure through varying the filling ratio during hydrothermal treatment. Highlights: → Selective formation of VO 2 polymorphs by controlling hydrothermal pressure. → Ground state energy characteristics were revealed for the first time. → Phase transformation mechanism was clearly elucidated.

  8. Development of plant dynamic analysis code for integrated self-pressurized water reactor (ISPDYN), and comparative study of pressure control methods

    International Nuclear Information System (INIS)

    Kusunoki, Tsuyoshi; Yokomura, Takeyoshi; Nabeshima, Kunihiko; Shimazaki, Junya; Shinohara, Yoshikuni.

    1988-01-01

    This report describes the development of plant dynamic analysis code (ISPDYN) for integrated self-pressurized water reactor, and comparative study of pressure control methods with this code. ISPDYN is developed for integrated self-pressurized water reactor, one of the trial design by JAERI. In the transient responses, the calculated results by ISPDYN are in good agreement with the DRUCK calculations. In addition, this report presents some sensitivity studies for selected cases. Computing time of this code is very short so as about one fifth of real time. The comparative study of self-pressurized system with forced-pressurized system by this code, for rapid load decrease and increase cases, has provided useful informations. (author)

  9. Role of olmesartan in combination therapy in blood pressure control and vascular function

    Directory of Open Access Journals (Sweden)

    Carlos M Ferrario

    2010-08-01

    Full Text Available Carlos M Ferrario, Ronald D SmithWake Forest University School of Medicine, Winston-Salem, North Carolina, USAAbstract: Angiotensin receptor blockers have emerged as a first-line therapy in the management of hypertension and hypertension-related comorbidities. Since national and international guidelines have stressed the need to control blood pressure to <140/90 mmHg in uncomplicated hypertension and <130/80 mmHg in those with associated comorbidities such as diabetes or chronic kidney disease, these goal blood pressures can only be achieved through combination therapy. Of several drugs that can be effectively combined to attain the recommended blood pressure goals, fixed-dose combinations of angiotensin receptor blockers and the calcium channel blocker amlodipine provide additive antihypertensive effects associated with a safe profile and increased adherence to therapy. In this article, we review the evidence regarding the beneficial effects of renin–angiotensin system blockade with olmesartan medoxomil and amlodipine in terms of blood pressure control and improvement of vascular function and target organ damage.Keywords: amlodipine, angiotensin receptor blockers, angiotensin-converting enzyme 2, hypertension, renin–angiotensin system

  10. The importance of neurotransmitters in the central control of the blood pressure

    International Nuclear Information System (INIS)

    Pfitscher-Klausmair, A.

    1990-12-01

    In anaesthetized cats, the nucleus tractus solitarii (NTS) and the locus coeruleus (LC) were bilaterally superfused through push-pull cannulae with artificial cerebrospinal fluid. Catecholamines were determined in the superfusate by a radioenzymatic assay, gamma-aminobutyric acid (GABA) was determined in the superfusate and homogenate with glutamate by an enzymatic and fluorimetric assay. In the NTS and LC the resting release of catecholamines varied rhythmically. To investigate the function of catecholaminergic neurons and GABAergic neurons of the NTS in cardiovascular control, the influence of experimentally induced blood pressure changes on the rates of release of the endogenous catecholamines dopamine, noradrenaline and adrenaline in the NTS was observed. The decreased noradrenaline and adrenaline release elicited by increases in blood pressure and the reduced release of dopamine induced by decreases in blood pressure suggest a hypertensive function of noradrenaline and adrenaline and a hypotensive role of dopamine at the level of the rostral and intermediate NTS. Bilateral carotid occlusion led to a very pronounced increase in the release rate of GABA in the rostral NTS. This result demonstrate the hypertensive function of GABA in the NTS. Thus underlining the importance of catecholaminergic and GABAergic neurons of the NTS in central cardiovascular control. The GABA-transaminase inhibitor Vigabatrin was injected wistar Kyoto rats and spontaneously hypertensive rats. GABA-Transaminase inhibition was accompanied by an increase of GABA concentration in the rat brain. The administration of Vigabatrin had no influence on the blood pressure but on the body wight of the rats. (Author)

  11. The importance of neurotransmitters in the central control of the blood pressure

    International Nuclear Information System (INIS)

    Pfitscher-Klausmair, A.

    1990-12-01

    In anaesthetized cats, the nucleus tractus solitarii (NTS) and the locus coeruleus (LC) were bilaterally superfused through push-pull cannulae with artificial cerebrospinal fluid. Catecholamines were determined in the superfusate by a radioenzymatic assay, gamma-aminobutyric acid (GABA) was determined in the superfusate and homogenitate with glutamate by an enzymatic and fluorimetric assay. In the NTS and LC the resting release of catecholamines varied rhythmically. To investigate the function of catecholaminergic neurons and GABAergic neurons of the NTS in cardiovascular control, the influence of experimentally induced blood pressure changes on the rates of the endogenous catecholamines dopamine,noradrenaline and adrenaline in the NTS was observed. The decreased noradrenaline and adrenaline release elicited by increases in blood pressure and the reduced release of dopamine induced by decreases in blood pressure suggest a hypertensive function on noradrenaline and adrenaline and a hypotensive role of dopamine at the level of the rostral and intermediate NTS. Bilateral carotid occlusion led to a very pronounced increase in the release rate of GABA in the rostral NTS. This result demonstrated the hypertensive function of GABA in the NTS, thus underlining the importance of catecholaminergic and GABAergic neurons of the NTS in central cardiovascular control. The GABA-transaminase inhibitor Vigabatrin was injected in kyoto rats and spontaneously hypertensive rats. GABA-Transaminase inhibition was accompanied by an increase of GABA concentration in the rat brain. The administration of Vigabatrin had no influence on the blood pressure but on body weight of the rats. (author)

  12. Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation.

    Science.gov (United States)

    Kaczka, David W; Lutchen, Kenneth R

    2004-04-01

    The ability to provide forced oscillatory excitation of the respiratory system can be useful in mechanical impedance measurements as well as high frequency ventilation (HFV). Experimental systems currently used for generating forced oscillations are limited in their ability to provide high amplitude flows or maintain the respiratory system at a constant mean pressure during excitation. This paper presents the design and implementation of a pneumatic pressure oscillator based on a proportional solenoid valve. The device is capable of providing forced oscillatory excitations to the respiratory system over a bandwidth suitable for mechanical impedance measurements and HVF. It delivers high amplitude flows (> 1.4 l/s) and utilizes a servo-control mechanism to maintain a load at a fixed mean pressure during simultaneous oscillation. Under open-loop conditions, the device exhibited a static hysteresis of approximately 7%, while its dynamic magnitude and phase responses were flat out to 10 Hz. Broad-band measurement of total harmonic distortion was approximately 19%. Under closed-loop conditions, the oscillator was able to maintain a mechanical test load at both positive and negative mean pressures during oscillatory excitations from 0.1 to 10.0 Hz. Impedance of the test load agreed closely with theoretical predictions. We conclude that this servo-controlled oscillator can be a useful tool for respiratory impedance measurements as well as HFV.

  13. Optimization of a pressure control valve for high power automatic transmission considering stability

    Science.gov (United States)

    Jian, Hongchao; Wei, Wei; Li, Hongcai; Yan, Qingdong

    2018-02-01

    The pilot-operated electrohydraulic clutch-actuator system is widely utilized by high power automatic transmission because of the demand of large flowrate and the excellent pressure regulating capability. However, a self-excited vibration induced by the inherent non-linear characteristics of valve spool motion coupled with the fluid dynamics can be generated during the working state of hydraulic systems due to inappropriate system parameters, which causes sustaining instability in the system and leads to unexpected performance deterioration and hardware damage. To ensure a stable and fast response performance of the clutch actuator system, an optimal design method for the pressure control valve considering stability is proposed in this paper. A non-linear dynamic model of the clutch actuator system is established based on the motion of the valve spool and coupling fluid dynamics in the system. The stability boundary in the parameter space is obtained by numerical stability analysis. Sensitivity of the stability boundary and output pressure response time corresponding to the valve parameters are identified using design of experiment (DOE) approach. The pressure control valve is optimized using particle swarm optimization (PSO) algorithm with the stability boundary as constraint. The simulation and experimental results reveal that the optimization method proposed in this paper helps in improving the response characteristics while ensuring the stability of the clutch actuator system during the entire gear shift process.

  14. [Meta-analysis of the efficacy of cochlear implantation in deaf patients with inner ear malformation].

    Science.gov (United States)

    Xu, Qingqing; Zhai, Suoqiang; Han, Dongyi; Yang, Shiming; Shen, Weidong

    2014-04-01

    Assess and compare the clinical efficacy and safety of cochlear implantation in deaf patients with inner ear malformation and in the ones with normal inner ear structure, so that to clarify whether it is effective to restore hearing for the deaf patients with inner ear malformation. The literature with relevant key words were retrieved in the databases including PubMed, YZ365. com, WANFANG data, CMJD, CHKD and CNKI with language limited to Chinese and English. Extracted data included author, year of publication, diagnosis, treatment, et al. The clinical efficacy of cochlear implantation was assessed by the complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Meta-analysis was performed using random or fixed effects model according to the heterogeneity of data. There were 11 randomized control studies involving 655 patients included in this study. There was no statistically significant difference among the deaf patients in mixed inner ear-malformation group, Mondini group and large vestibular aqueduct syndrome group in the aspects of postoperative complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Cochlear implantation could be the way of treatment and rehabilitation for deaf patients with inner ear malformation. Further controlled studies with longer follow-up periods and more multiracial cases included may help to evaluate the efficacy of cochlear implantation for deaf patients with inner ear malformation more reliably.

  15. Fgf8 and Fgf3 are required for zebrafish ear placode induction, maintenance and inner ear patterning.

    Science.gov (United States)

    Léger, Sophie; Brand, Michael

    2002-11-01

    The vertebrate inner ear develops from initially 'simple' ectodermal placode and vesicle stages into the complex three-dimensional structure which is necessary for the senses of hearing and equilibrium. Although the main morphological events in vertebrate inner ear development are known, the genetic mechanisms controlling them are scarcely understood. Previous studies have suggested that the otic placode is induced by signals from the chordamesoderm and the hindbrain, notably by fibroblast growth factors (Fgfs) and Wnt proteins. Here we study the role of Fgf8 as a bona-fide hindbrain-derived signal that acts in conjunction with Fgf3 during placode induction, maintenance and otic vesicle patterning. Acerebellar (ace) is a mutant in the fgf8 gene that results in a non-functional Fgf8 product. Homozygous mutants for acerebellar (ace) have smaller ears that typically have only one otolith, abnormal semi-circular canals, and behavioral defects. Using gene expression markers for the otic placode, we find that ace/fgf8 and Fgf-signaling are required for normal otic placode formation and maintenance. Conversely, misexpression of fgf8 or Fgf8-coated beads implanted into the vicinity of the otic placode can increase ear size and marker gene expression, although competence to respond to the induction appears restricted. Cell transplantation experiments and expression analysis suggest that Fgf8 is required in the hindbrain in the rhombomere 4-6 area to restore normal placode development in ace mutants, in close neighbourhood to the forming placode, but not in mesodermal tissues. Fgf3 and Fgf8 are expressed in hindbrain rhombomere 4 during the stages that are critical for placode induction. Joint inactivation of Fgf3 and Fgf8 by mutation or antisense-morpholino injection causes failure of placode formation and results in ear-less embryos, mimicking the phenotype we observe after pharmacological inhibition of Fgf-signaling. Fgf8 and Fgf3 together therefore act during induction

  16. Association of microRNA 146 with middle ear hyperplasia in pediatric otitis media.

    Science.gov (United States)

    Samuels, Tina L; Yan, Justin; Khampang, Pawjai; MacKinnon, Alexander; Hong, Wenzhou; Johnston, Nikki; Kerschner, Joseph E

    2016-09-01

    Toll-like receptor signaling activated by bacterial otitis media pathogens in the middle ear has been shown to play a key role in OM susceptibility, pathogenesis and recovery. Recent studies implicate microRNA 146 (miR-146) in regulation of inflammation via negative feedback of toll-like receptor signaling (TLR) in a wide variety of tissues, however its involvement in otitis media is unknown. Human middle ear epithelial cells were stimulated with proinflammatory cytokines, interleukin 1 beta or tumor necrosis factor alpha, for two to twenty-four hours. Middle ear biopsies were collected from children with otitis media with effusion (n = 20), recurrent otitis media (n = 9), and control subjects undergoing cochlear implantation (n = 10). miR-146a, miR-146b expression was assayed by quantitative PCR (qPCR). Expression of miR-146 targets involved in TLR signaling, IRAK1 and TRAF6, was assayed by qPCR in middle ear biopsies. Middle ear biopsies were cryosectioned and epithelial thickness measured by a certified pathologist. Proinflammatory cytokines induced expression of miR-146 in middle ear epithelial cells in vitro. Middle ear miR-146a and miR-146b expression was elevated in otitis media patients relative to control subjects and correlated with middle ear epithelial thickness. A trend towards inverse correlation was observed between miR-146 and TRAF6 expression in the clinical population. This report is the first to assess miRNA expression in a clinical population with OM. Findings herein suggest miR-146 may play a role in OM. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. The ototoxic effect of intratympanic terbinafine applied in the middle ear of rats

    Science.gov (United States)

    2013-01-01

    Background Otomycosis is defined as an infection of the external ear canal with fungal agents. The treatment of the disease is cleansing and drying of the external ear canal, identification and treatment of any predisposing factors and application of topical antifungal agents. Terbinafine is used as an antifungal agent to treat otomycosis. We proposed to investigate the probable ototoxic effect of terbinafine solution on auditory brain stem response (ABR) and distortion product otoacoustic emission (DPOAE) when applied intratympanically in the middle ear of rats. Methods The experiment was performed on 30 female Wistar albino rats. Thirty animals were divided into three groups of 10 animals each. 1% terbinafine solution was administered to the first group (group T). The second group (group G) was administered 40 mg/ml gentamicin solution (ototoxic control). The third group (group S) was administered saline solution (negative control). Baseline DPOAE measurements and ABR testing from the left ears were obtained from the animals in all groups under general anesthesia. Ear solutions were applied in the middle ear intratympanically with a dental needle. Treatment was initiated after baseline measurements and repeated once every two days for fifteen days. Results Pre and post-treatment DPOAE responses for all tested frequencies of group T and Group S showed no statistically significant difference. However, the group G demonstrated a significant change in ABR thresholds and DPOAE responses. Conclusions Terbinafine solution is a broad spectrum antifungal agent effective in the treatment of otomycosis. The present study demonstrated that its direct administration in the middle ear of rats does not affect inner ear function as measured by ABR and DPOAE responses. PMID:23663536

  18. Different systolic blood pressure targets for people with history of stroke or transient ischaemic attack: PAST-BP (Prevention After Stroke—Blood Pressure) randomised controlled trial

    Science.gov (United States)

    McManus, Richard J; Roalfe, Andrea; Fletcher, Kate; Taylor, Clare J; Martin, Una; Virdee, Satnam; Greenfield, Sheila; Hobbs, F D Richard

    2016-01-01

    Objective To assess whether using intensive blood pressure targets leads to lower blood pressure in a community population of people with prevalent cerebrovascular disease. Design Open label randomised controlled trial. Setting 99 general practices in England, with participants recruited in 2009-11. Participants People with a history of stroke or transient ischaemic attack whose systolic blood pressure was 125 mm Hg or above. Interventions Intensive systolic blood pressure target (different target, patients in both arms were actively managed in the same way with regular reviews by the primary care team. Main outcome measure Change in systolic blood pressure between baseline and 12 months. Results 529 patients (mean age 72) were enrolled, 266 to the intensive target arm and 263 to the standard target arm, of whom 379 were included in the primary analysis (182 (68%) intensive arm; 197 (75%) standard arm). 84 patients withdrew from the study during the follow-up period (52 intensive arm; 32 standard arm). Mean systolic blood pressure dropped by 16.1 mm Hg to 127.4 mm Hg in the intensive target arm and by 12.8 mm Hg to 129.4 mm Hg in the standard arm (difference between groups 2.9 (95% confidence interval 0.2 to 5.7) mm Hg; P=0.03). Conclusions Aiming for target below 130 mm Hg rather than 140 mm Hg for systolic blood pressure in people with cerebrovascular disease in primary care led to a small additional reduction in blood pressure. Active management of systolic blood pressure in this population using a blood pressure. Trial registration Current Controlled Trials ISRCTN29062286. PMID:26919870

  19. Pressure RElieving Support SUrfaces: a Randomised Evaluation 2 (PRESSURE 2): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Brown, Sarah; Smith, Isabelle L; Brown, Julia M; Hulme, Claire; McGinnis, Elizabeth; Stubbs, Nikki; Nelson, E Andrea; Muir, Delia; Rutherford, Claudia; Walker, Kay; Henderson, Valerie; Wilson, Lyn; Gilberts, Rachael; Collier, Howard; Fernandez, Catherine; Hartley, Suzanne; Bhogal, Moninder; Coleman, Susanne; Nixon, Jane E

    2016-12-20

    Pressure ulcers represent a major burden to patients, carers and the healthcare system, affecting approximately 1 in 17 hospital and 1 in 20 community patients. They impact greatly on an individual's functional status and health-related quality of life. The mainstay of pressure ulcer prevention practice is the provision of pressure redistribution support surfaces and patient repositioning. The aim of the PRESSURE 2 study is to compare the two main mattress types utilised within the NHS: high-specification foam and alternating pressure mattresses, in the prevention of pressure ulcers. PRESSURE 2 is a multicentre, open-label, randomised, double triangular, group sequential, parallel group trial. A maximum of 2954 'high-risk' patients with evidence of acute illness will be randomised on a 1:1 basis to receive either a high-specification foam mattress or alternating-pressure mattress in conjunction with an electric profiling bed frame. The primary objective of the trial is to compare mattresses in terms of the time to developing a new Category 2 or above pressure ulcer by 30 days post end of treatment phase. Secondary endpoints include time to developing new Category 1 and 3 or above pressure ulcers, time to healing of pre-existing Category 2 pressure ulcers, health-related quality of life, cost-effectiveness, incidence of mattress change and safety. Validation objectives are to determine the responsiveness of the Pressure Ulcer Quality of Life-Prevention instrument and the feasibility of having a blinded endpoint assessment using photography. The trial will have a maximum of three planned analyses with unequally spaced reviews at event-driven coherent cut-points. The futility boundaries are constructed as non-binding to allow a decision for stopping early to be overruled by the Data Monitoring and Ethics Committee. The double triangular, group sequential design of the PRESSURE 2 trial will provide an efficient design through the possibility of early stopping for

  20. Aging considerations for PWR [pressurized water reactor] control rod drive mechanisms and reactor internals

    International Nuclear Information System (INIS)

    Ware, A.G.

    1988-01-01

    This paper describes age-related degradation mechanisms affecting life extension of pressurized water reactor control rod drive mechanisms and reactor internals. The major sources of age-related degradation for control rod drive mechanisms are thermal transients such as plant heatups and cooldowns, latchings and unlatchings, long-term aging effects on electrical insulation, and the high temperature corrosive environment. Flow induced loads, the high-temperature corrosive environment, radiation exposure, and high tensile stresses in bolts all contribute to aging related degradation of reactor internals. Another problem has been wear and fretting of instrument guide tubes. The paper also discusses age-related failures that have occurred to date in pressurized water reactors

  1. Are managerial pressure, technological control and intrinsic motivation effective in improving data quality?

    International Nuclear Information System (INIS)

    Molina, Roger; Unsworth, Kerrie; Hodkiewicz, Melinda; Adriasola, Elisa

    2013-01-01

    Can data collectors be “pushed” into collecting high quality data or would being “pulled” be more effective? This paper finds that managers should be careful of the degree to which “push” factors, such as managerial pressure and technological input control, are relied upon. While they may be helpful for motivating those data collectors who are not intrinsically motivated, they are either not helpful or may discourage those data collectors who are intrinsically motivated. Instead, self-concordance may act as a longer-term, more stable approach to increasing the motivation of data collectors and thus increasing the quality of data that enter reliability systems. This study uses a sequential mixed-method approach involving interviews with 20 data collectors and a quantitative survey of 109 data collectors in a water utility. It examines the interactive effect of managerial pressure, technological input control and self-concordance on data collection performance

  2. Gentamicin pharmacokinetics in the chicken inner ear.

    Science.gov (United States)

    Bunting, Eric C; Park, Debra L; Durham, Dianne; Girod, Douglas A

    2004-06-01

    Avians have the unique ability to regenerate cochlear hair cells that are lost due to ototoxins or excessive noise. Many methodological techniques are available to damage the hair cells for subsequent scientific study. A recent method utilizes topical application of an ototoxic drug to the round window membrane. The current study examines the pharmacokinetics of gentamicin in the inner ear of chickens following topical application to the round window membrane or a single systemic high dose given intraperitoneally. Chickens were given gentamicin topically or systemically and survived for 1, 4, 12, 24, or 120 h (controls at 4 and 120 h). Serum and perilymph samples were obtained prior to sacrifice and measured for gentamicin levels. Results revealed higher levels of gentamicin in the perilymph of topically treated chickens than systemically treated chickens, with significant amounts of gentamicin still present in both at the latest survival time of 5 days. As expected, systemically treated chickens had much higher levels of gentamicin in the serum than topically treated chickens. Advantages and disadvantages to each method of drug administration are discussed.

  3. Influence of isoflurane on the diastolic pressure-flow relationship and critical occlusion pressure during arterial CABG surgery: a randomized controlled trial

    OpenAIRE

    Hinz, Jos?; Mansur, Ashham; Hanekop, Gerd G.; Weyland, Andreas; Popov, Aron F.; Schmitto, Jan D.; Gr?ne, Frank F. G.; Bauer, Martin; Kazmaier, Stephan

    2016-01-01

    The effects of isoflurane on the determinants of blood flow during Coronary Artery Bypass Graft (CABG) surgery are not completely understood. This study characterized the influence of isoflurane on the diastolic Pressure-Flow (P-F) relationship and Critical Occlusion Pressure (COP) during CABG surgery. Twenty patients undergoing CABG surgery were studied. Patients were assigned to an isoflurane or control group. Hemodynamic and flow measurements during CABG surgery were perf...

  4. Control of the ORR-PSF pressure-vessel surveillance irradiation experiment temperature

    International Nuclear Information System (INIS)

    Miller, L.F.

    1982-01-01

    Control of the Oak Ridge Research Reactor Pool Side Facility (ORR-PSF) pressure vessel surveillance irradiation experiment temperature is implemented by digital computer control of electrical heaters under fixed cooling conditions. Cooling is accomplished with continuous flows of water in pipes between specimen sets and of helium-neon gas in the specimen set housings. Control laws are obtained from solutions of the discrete-time Riccati equation and are implemented with direct digital control of solid state relays in the electrical heater circuit. Power dissipated by the heaters is determined by variac settings and the percent of time that the solid state relays allow power to be supplied to the heaters. Control demands are updated every forty seconds

  5. Simultaneous real-time control of the current and pressure profiles in JET: experiments and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Mazon, D.; Laborde, L.; Litaudon, X.; Moreau, D.; Zabeo, L.; Joffrin, E. [Association Euratom-CEA Cadarache (DSM/DRFC), 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Murari, A. [Consorzio RFX Association Euratom-ENEA, Padova (Italy); Ariola, M.; Albanese, R.; Tommasi, G. de; Pironti, A. [Association Euratom-ENEA, CREATE, Napoly (Italy); Moreau, D. [EFDA-JET CSU, Culham Science Centre, Abingdon, OX (United Kingdom); Tala, T. [Euratom-Tekes Association, VTT Processes (Finland); Crisanti, F.; Pericoli-Ridolfini, V.; Tuccillo, A. [Association Euratom-ENEA, C.R. Frascati (Italy); Baar, M. de; Vries, P. de [Euratom-FOM Association, TEC Cluster, Nieuwegein (Netherlands); De la Luna, E. [Euratom-Ciemat Association (Spain); Felton, R.; Corrigan, G. [Euratom-UKAEA Association, Culham Science Centre, Abingdon (United Kingdom)

    2004-07-01

    Real-time control of the plasma profiles (current density, pressure and flow) is one of the major issues for sustaining internal transport barriers (ITB) in a high performance plasma, with a large bootstrap current fraction. We have recently investigated the experimental and numerical aspects of the simultaneous control of the current and pressure profiles in JET ITB discharges. The current density and the electron temperature were successfully controlled via the safety factor profile (or via its inverse the tau-profile) and the {rho}{sup *}{sub Te} profile respectively. The results of these new studies are presented. With only a limited number of actuators, the technique aims at minimizing an integral square error signal which combines the 2 profiles, rather than attempting to control plasma parameters at some given radii with great precision. The resulting fuzziness of the control scheme allows the plasma to relax towards a physically accessible non-linear state which may not be accurately known in advance, but is close enough to the requested one to provide the required plasma performance. Closed loop experiments have allow to reach different target q and {rho}{sup *}{sub Te} profiles, and to some degree, to displace the region of maximum electron temperature gradient. The control has also shown some robustness in front of rapid transients.

  6. Remote-controlled television for locating leaking tubes in pressurized-water reactor steam generators

    International Nuclear Information System (INIS)

    Cormault, P.; Denis, J.

    1978-01-01

    The Scarabee system is designed for observation of the tubes in water boxes of pressurized-water reactor nuclear-power-station steam generators. It consists essentially of a camera and a projector used as a marker, both of which swivel freely. The whole unit is housed in a water-tight container which can easily be decontaminated. Remote control of camera and marker movement is carried out from a console. (author)

  7. On Electrohydraulic Pressure Control for Power Steering Applications : Active Steering for Road Vehicles

    OpenAIRE

    Dell'Amico, Alessandro

    2016-01-01

    This thesis deals with the Electrohydraulic Power Steering system for road vehicles, using electronic pressure control valves. With an ever increasing demand for safer vehicles and fewer traffic accidents, steering-related active safety functions are becoming more common in modern vehicles. Future road vehicles will also evolve towards autonomous vehicles, with several safety, environmental and financial benefits. A key component in realising such solutions is active steering. The power steer...

  8. Blood Pressure Control in Aging Predicts Cerebral Atrophy Related to Small-Vessel White Matter Lesions

    Directory of Open Access Journals (Sweden)

    Kyle C. Kern

    2017-05-01

    Full Text Available Cerebral small-vessel damage manifests as white matter hyperintensities and cerebral atrophy on brain MRI and is associated with aging, cognitive decline and dementia. We sought to examine the interrelationship of these imaging biomarkers and the influence of hypertension in older individuals. We used a multivariate spatial covariance neuroimaging technique to localize the effects of white matter lesion load on regional gray matter volume and assessed the role of blood pressure control, age and education on this relationship. Using a case-control design matching for age, gender, and educational attainment we selected 64 participants with normal blood pressure, controlled hypertension or uncontrolled hypertension from the Northern Manhattan Study cohort. We applied gray matter voxel-based morphometry with the scaled subprofile model to (1 identify regional covariance patterns of gray matter volume differences associated with white matter lesion load, (2 compare this relationship across blood pressure groups, and (3 relate it to cognitive performance. In this group of participants aged 60–86 years, we identified a pattern of reduced gray matter volume associated with white matter lesion load in bilateral temporal-parietal regions with relative preservation of volume in the basal forebrain, thalami and cingulate cortex. This pattern was expressed most in the uncontrolled hypertension group and least in the normotensives, but was also more evident in older and more educated individuals. Expression of this pattern was associated with worse performance in executive function and memory. In summary, white matter lesions from small-vessel disease are associated with a regional pattern of gray matter atrophy that is mitigated by blood pressure control, exacerbated by aging, and associated with cognitive performance.

  9. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    Science.gov (United States)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  10. Longitudinal non-invasive perilymphatic pressure measurement in patients with Meniere's disease

    NARCIS (Netherlands)

    Rosingh, HJ; Wit, HP; Sulter, AM; Albers, FWJ

    1997-01-01

    The homeostasis of inner-ear fluids is essential for the functions of hearing and equilibrium. Inner-ear disorders, such as Meniere's disease, are affected by inner-ear pressure. The displacement of the human tympanic membrane can be studied by means of the MMS-10 Tympanic Displacement Analyser

  11. Body lift, drag and power are relatively higher in large-eared than in small-eared bat species

    DEFF Research Database (Denmark)

    Håkansson, Jonas; Jakobsen, Lasse; Hedenström, Anders

    2017-01-01

    Bats navigate the dark using echolocation. Echolocation is enhanced by external ears, but external ears increase the projected frontal area and reduce the streamlining of the animal. External ears are thus expected to compromise flight efficiency, but research suggests that very large ears may mi....... The result of this trade-off would be the eco-morphological correlation in bat flight, with large-eared bats generally adopting slow-flight feeding strategies....

  12. Barley seed ageing: genetics behind the dry elevated pressure of oxygen ageing and moist controlled deterioration

    Directory of Open Access Journals (Sweden)

    Manuela eNagel

    2016-03-01

    Full Text Available Experimental seed ageing approaches intend to mimic seed deterioration processes to achieve a storage interval reduction. Common methods apply higher seed moisture levels and temperatures. In contrast, the elevated partial pressure of oxygen (EPPO approach treats dry seed stored at ambient temperatures with high oxygen pressure. To analyse the genetic background of seed longevity and the effects of seed ageing under dry conditions, the EPPO approach was applied to the progeny of the Oregon Wolfe Barley (OWB mapping population. In comparison to a non-treated control and a control high-pressure nitrogen treatment, EPPO stored seeds showed typical symptoms of ageing with a significant reduction of normal seedlings, slower germination, and less total germination. Thereby, the parent Dom (OWB-D, carrying dominant alleles, is more sensitive to ageing in comparison to the population mean and in most cases to the parent Rec (OWB-R, carrying recessive alleles. Quantitative trait locus (QTL analyses using 2,832 markers revealed 65 QTLs, including two major loci for seed vigor on 2H and 7H. QTLs for EPPO tolerance were detected on 3H, 4H, and 5H. An applied controlled deterioration (CD treatment (aged at higher moisture level and temperature revealed a tolerance QTL on 5H, indicating that the mechanism of seed deterioration differs in part between EPPO or CD conditions.

  13. Real-time control of current and pressure profiles in tokamak plasmas

    International Nuclear Information System (INIS)

    Laborde, L.

    2005-12-01

    Recent progress in the field of 'advanced tokamak scenarios' prefigure the operation regime of a future thermonuclear fusion power plant. Compared to the reference regime, these scenarios offer a longer plasma confinement time thanks to increased magnetohydrodynamic stability and to a better particle and energy confinement through a reduction of plasma turbulence. This should give access to comparable fusion performances at reduced plasma current and could lead to a steady state fusion reactor since the plasma current could be entirely generated non-inductively. Access to this kind of regime is provided by the existence of an internal transport barrier, linked to the current profile evolution in the plasma, which leads to steep temperature and pressure profiles. The comparison between heat transport simulations and experiments allowed the nature of the barriers to be better understood as a region of strongly reduced turbulence. Thus, the control of this barrier in a stationary manner would be a remarkable progress, in particular in view of the experimental reactor ITER. The Tore Supra and JET tokamaks, based in France and in the United Kingdom, constitute ideal instruments for such experiments: the first one allows stationary plasmas to be maintained during several minutes whereas the second one provides unique fusion performances. In Tore Supra, real-time control experiments have been accomplished where the current profile width and the pressure profile gradient were controlled in a stationary manner using heating and current drive systems as actuators. In the JET tokamak, the determination of an empirical static model of the plasma allowed the current and pressure profiles to be simultaneously controlled and so an internal transport barrier to be sustained. Finally, the identification of a dynamic model of the plasma led to the definition of a new controller capable, in principle, of a more efficient control. (author)

  14. Structure and function of the mammalian middle ear. I: Large middle ears in small desert mammals.

    Science.gov (United States)

    Mason, Matthew J

    2016-02-01

    Many species of small desert mammals are known to have expanded auditory bullae. The ears of gerbils and heteromyids have been well described, but much less is known about the middle ear anatomy of other desert mammals. In this study, the middle ears of three gerbils (Meriones, Desmodillus and Gerbillurus), two jerboas (Jaculus) and two sengis (elephant-shrews: Macroscelides and Elephantulus) were examined and compared, using micro-computed tomography and light microscopy. Middle ear cavity expansion has occurred in members of all three groups, apparently in association with an essentially 'freely mobile' ossicular morphology and the development of bony tubes for the middle ear arteries. Cavity expansion can occur in different ways, resulting in different subcavity patterns even between different species of gerbils. Having enlarged middle ear cavities aids low-frequency audition, and several adaptive advantages of low-frequency hearing to small desert mammals have been proposed. However, while Macroscelides was found here to have middle ear cavities so large that together they exceed brain volume, the bullae of Elephantulus are considerably smaller. Why middle ear cavities are enlarged in some desert species but not others remains unclear, but it may relate to microhabitat. © 2015 Anatomical Society.

  15. Prenatal evaluation of the middle ear and diagnosis of middle ear hypoplasia using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Katorza, Eldad; Nahama-Allouche, Catherine; Ducou le Pointe, Hubert; Garel, Catherine [Hopital d' Enfants Armand-Trousseau, Service de Radiologie, Paris (France); Castaigne, Vanina [Hopital Saint-Antoine, Service de Gynecologie-Obstetrique, Paris (France); Gonzales, Marie; Marlin, Sandrine [Hopital d' Enfants Armand-Trousseau, Service de Genetique et Embryologie medicales, Paris (France); Galliani, Eva [Hopital d' Enfants Armand-Trousseau, Service de Chirurgie maxillo-faciale, Paris (France); Jouannic, Jean-Marie; Rosenblatt, Jonathan [Hopital d' Enfants Armand-Trousseau, Service de Gynecologie-Obstetrique, Centre pluridisciplinaire de diagnostic prenatal, Paris (France)

    2011-05-15

    Analysis of the middle ear with fetal MRI has not been previously reported. To show the contribution of fetal MRI to middle ear imaging. The tympanic cavity was evaluated in 108 fetal cerebral MRI examinations (facial and/or cerebral malformation excluded) and in two cases, one of Treacher Collins syndrome (case 1) and the other of oculo-auriculo-vertebral (OUV) spectrum (case 2) with middle ear hypoplasia identified by MRI at 27 and 36 weeks' gestation, respectively. In all 108 fetuses (mean gestational age 32.5 weeks), the tympanic cavity and T2 hypointensity related to the ossicles were well visualised on both sides. Case 1 had micro/retrognathia and bilateral external ear deformity and case 2 had retrognathism with a left low-set and deformed ear. MRI made it possible to recognize the marked hypoplasia of the tympanic cavity, which was bilateral in case 1 and unilateral in case 2. Both syndromes are characterized by craniofacial abnormalities including middle ear hypoplasia, which cannot be diagnosed with US. The middle ear cavity can be visualized with fetal MRI. We emphasize the use of this imaging modality in the diagnosis of middle ear hypoplasia. (orig.)

  16. Rheological Properties of Extreme Pressure Greases Measured Using a Process Control Rheometer

    DEFF Research Database (Denmark)

    Glasscock, Julie; Smith, Robin S.

    2012-01-01

    A new process control rheometer (PCR) designed for use in industrial process flows has been used to measure the rheological properties of three extreme-pressure greases. The rheometer is a robust yet sensitive instrument designed to operate in an industrial processing environment in either in......-line or on-line configurations. The PCR was able to measure the rheological properties including the elastic modulus, viscous modulus, and complex viscosity of the greases which in an industrial flow application could be used as variables in a feedback system to control the process and the quality...

  17. Study of geometrical and operational parameters controlling the low frequency microjet atmospheric pressure plasma characteristics

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Rhee, J. K.; Moon, S. Y.; Choe, W.

    2006-01-01

    Controllability of small size atmospheric pressure plasma generated at low frequency in a pin to dielectric plane electrode configuration was studied. It was shown that the plasma characteristics could be controlled by geometrical and operational parameters of the experiment. Under most circumstances, continuous glow discharges were observed, but both the corona and/or the dielectric barrier discharge characteristics were observed depending on the position of the pin electrode. The plasma size and the rotational temperature were also varied by the parameters. The rotational temperature was between 300 and 490 K, being low enough to treat thermally sensitive materials

  18. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    International Nuclear Information System (INIS)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I.

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (author)

  19. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (autho0008.

  20. State-space model predictive control method for core power control in pressurized water reactor nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guo Xu; Wu, Jie; Zeng, Bifan; Wu, Wangqiang; Ma, Xiao Qian [School of Electric Power, South China University of Technology, Guangzhou (China); Xu, Zhibin [Electric Power Research Institute of Guangdong Power Grid Corporation, Guangzhou (China)

    2017-02-15

    A well-performed core power control to track load changes is crucial in pressurized water reactor (PWR) nuclear power stations. It is challenging to keep the core power stable at the desired value within acceptable error bands for the safety demands of the PWR due to the sensitivity of nuclear reactors. In this paper, a state-space model predictive control (MPC) method was applied to the control of the core power. The model for core power control was based on mathematical models of the reactor core, the MPC model, and quadratic programming (QP). The mathematical models of the reactor core were based on neutron dynamic models, thermal hydraulic models, and reactivity models. The MPC model was presented in state-space model form, and QP was introduced for optimization solution under system constraints. Simulations of the proposed state-space MPC control system in PWR were designed for control performance analysis, and the simulation results manifest the effectiveness and the good performance of the proposed control method for core power control.

  1. Older Women with Controlled Isolated Systolic Hypertension: Exercise and Blood Pressure.

    Science.gov (United States)

    Ubolsakka-Jones, Chulee; Sangthong, Benjarat; Aueyingsak, Sahachat; Jones, David A

    2016-06-01

    Exercise is generally regarded as beneficial for health, but the consequent increases in blood pressure might pose a risk for hypertensive subjects. The purpose of this study was to determine blood pressure responses to dynamic exercise and sustained handgrip in patients with isolated systolic hypertension (ISH) who were stable on medication. Nineteen female ISH patients (66 ± 5 yr) and 19 age-matched normotensive (NT) female controls undertook a 5-min cycle exercise (60% heart rate reserve [HRR]) and a 2-min handgrip exercise (30% maximum voluntary contraction). Blood pressure responses were measured using an oscillometric cuff, together with heart rate and resting brachial pulse transit times. Systolic blood pressure (SBP) levels after cycle exercise were 194 ± 18 and 153 ± 19 mm Hg for ISH and NT, respectively, with the increase above resting being greater for ISH (P exercise, SBP rose to 168 ± 19 and 140 ± 8 mm Hg for ISH and NT, respectively. The increases above baseline were greater for ISH both during the exercise and postexercise circulatory occlusion (P = 0.017). The increase in DBP levels during exercise and postexercise occlusion were similar in ISH and NT, suggesting little difference in metaboreflex sensitivity. Pulse transit time was shorter for ISH compared with NT (166 ± 6 ms and 242 ± 24 ms, respectively, P exercises, which may constitute a risk for cardiovascular incidents.

  2. Real-time combustion control and diagnostics sensor-pressure oscillation monitor

    Science.gov (United States)

    Chorpening, Benjamin T [Morgantown, WV; Thornton, Jimmy [Morgantown, WV; Huckaby, E David [Morgantown, WV; Richards, George A [Morgantown, WV

    2009-07-14

    An apparatus and method for monitoring and controlling the combustion process in a combustion system to determine the amplitude and/or frequencies of dynamic pressure oscillations during combustion. An electrode in communication with the combustion system senses hydrocarbon ions and/or electrons produced by the combustion process and calibration apparatus calibrates the relationship between the standard deviation of the current in the electrode and the amplitudes of the dynamic pressure oscillations by applying a substantially constant voltage between the electrode and ground resulting in a current in the electrode and by varying one or more of (1) the flow rate of the fuel, (2) the flow rate of the oxidant, (3) the equivalence ratio, (4) the acoustic tuning of the combustion system, and (5) the fuel distribution in the combustion chamber such that the amplitudes of the dynamic pressure oscillations in the combustion chamber are calculated as a function of the standard deviation of the electrode current. Thereafter, the supply of fuel and/or oxidant is varied to modify the dynamic pressure oscillations.

  3. Passive control of thermoacoustic instabilities in swirl-stabilized combustion at elevated pressures

    Directory of Open Access Journals (Sweden)

    L Justin Williams

    2016-09-01

    Full Text Available In this study, a porous insert is placed at the dump plane of a swirl-stabilized lean premixed combustor to passively suppress thermoacoustic instabilities. The diffuser-shaped annular ring of porous inert material influences the turbulent flow field directly, including recirculation zones and vortical and/or shear layer structures to passively control the acoustic performance of the combustor. The porous inert material is made of silicon carbide–hafnium carbide coated, high-strength, high-temperature-resistant open-cell foam materials. In this study, the porous insert concept is investigated at above-ambient operating pressures to demonstrate its suitability for practical combustion applications. Experiments are conducted in quartz and metal combustors, without and with the porous insert while varying operating pressure, equivalence ratio, and reactant flow rate. Measurements show that the porous insert, and consequent changes in the combustor flow field, decrease the sound pressure levels at the frequency of combustion instability at all operating conditions investigated in this study. The porous insert also decreases the broadband combustion noise, i.e. the measured sound pressure levels over a wide frequency range.

  4. Predictors of arterial blood pressure control during deliberate hypotension with sodium nitroprusside in children.

    Science.gov (United States)

    Spielberg, David R; Barrett, Jeffrey S; Hammer, Gregory B; Drover, David R; Reece, Tammy; Cohane, Carol A; Schulman, Scott R

    2014-10-01

    Sodium nitroprusside (SNP) is used to decrease arterial blood pressure (BP) during certain surgical procedures. There are limited data regarding efficacy of BP control with SNP. There are no data on patient and clinician factors that affect BP control. We evaluated the dose-response relationship of SNP in infants and children undergoing major surgery and performed a quantitative assessment of BP control. One hundred fifty-three subjects at 7 sites received a blinded infusion followed by open-label SNP during operative procedures requiring controlled hypotension. SNP was administered by continuous infusion and titrated to maintain BP control (mean arterial BP [MAP] within ±10% of clinician-defined target). BP was recorded using an arterial catheter. Statistical process control methodology was used to quantify BP control. A multivariable model assessed the effects of patient and procedural factors. BP was controlled an average 45.4% (SD 23.9%; 95% CI, 41.5%-49.18%) of the time. Larger changes in infusion rate were associated with worse BP control (7.99% less control for 1 μg·kg·min increase in average titration size, P = 0.0009). A larger difference between a patient's baseline and target MAP predicted worse BP control (0.93% worse control per 1-mm Hg increase in MAP difference, P = 0.0013). Both effects persisted in multivariable models. SNP was effective in reducing BP. However, BP was within the target range less than half of the time. No clinician or patient factors were predictive of BP control, although 2 inverse relationships were identified. These relationships require additional study and may be best coupled with exposure-response modeling to propose improved dosing strategies when using SNP for controlled hypotension in the pediatric population.

  5. Pressurized water reactor system model for control system design and analysis

    International Nuclear Information System (INIS)

    Cooper, K.F.; Cain, J.T.

    1975-01-01

    Satisfactory operation of present generation Pressurized Water Reactor (PWR) Nuclear Power systems requires that several independent and interactive control systems be designed. Since it is not practical to use an actual PWR system as a design tool, a mathematical model of the system must be developed as a design and analysis tool. The model presented has been developed to be used as an aid in applying optimal control theory to design and implement new control systems for PWR plants. To be applicable, the model developed must represent the PWR system in its normal operating range. For safety analysis the operating conditions of the system are usually abnormal and, therefore, the system modeling requirements are different from those for control system design and analysis

  6. Evaporation monitoring and composition control of alloy systems with widely differing vapor pressures

    International Nuclear Information System (INIS)

    Anklam, T.M.; Berzins, L.V.; Braun, D.G.; Haynam, C.; McClelland, M.A.; Meier, T.

    1994-10-01

    Lawrence Livermore National Laboratory is developing sensors and controls to improve and extend electron beam materials processing technology to alloy systems with constituents of widely varying vapor pressure. The approach under development involves using tunable lasers to measure the density and composition of the vapor plume. A laser based vaporizer control system for vaporization of a uranium-iron alloy has been previously demonstrated in multi-hundred hour, high rate vaporization experiments at LLNL. This paper reviews the design and performance of the uranium vaporization sensor and control system and discusses the extension of the technology to monitoring of uranium vaporization. Data is presented from an experiment in which titanium wire was fed into a molten niobium pool. Laser data is compared to deposited film composition and film cross sections. Finally, the potential for using this technique for composition control in melting applications is discussed

  7. Performance and control study of a low-pressure-ratio turbojet engine for a drone aircraft

    Science.gov (United States)

    Seldner, K.; Geyser, L. C.; Gold, H.; Walker, D.; Burgner, G.

    1972-01-01

    The results of analog and digital computer studies of a low-pressure-ratio turbojet engine system for use in a drone vehicle are presented. The turbojet engine consists of a four-stage axial compressor, single-stage turbine, and a fixed area exhaust nozzle. Three simplified fuel schedules and a generalized parameter fuel control for the engine system are presented and evaluated. The evaluation is based on the performance of each schedule or control during engine acceleration from a windmill start at Mach 0.8 and 6100 meters to 100 percent corrected speed. It was found that, because of the higher acceleration margin permitted by the control, the generalized parameter control exhibited the best dynamic performance.

  8. Importance of sustained and "tight" blood pressure control in patients with high cardiovascular risk.

    Science.gov (United States)

    Meredith, Peter A; Lloyd, Suzanne M; Ford, Ian; Elliott, Henry L

    2016-01-01

    A retrospective further analysis of the ACTION database evaluated the relationship between cardiovascular outcomes and the "quality" of the control of blood pressure (BP). The study population (n = 6287) comprised those patients with four BP measurements during year 1 subdivided according to the proportion of visits in which BP was controlled in relation to two BP targets: control groups for the major prespecified ACTION outcomes were investigated with Cox proportional hazards models. For all the prespecified cardiovascular endpoints the incidence declined as the proportion of visits with BP control increased. The greatest differences in outcomes between the different BP control groups were observed for the risk of stroke but were still apparent for all the other endpoints. For example, the risks for the primary outcome [hazard ratio (HR) 0.78; 95% confidence interval (CI) 0.67 to 0.90] were significantly less in the group with >_75% of visits with BP control than in the group with control. There were no significant treatment-related differences. Retrospective analyses are not definitive but these results highlight the importance of the attainment of BP control targets and the consistency of BP control during long-term follow-up.

  9. Dynamic modeling and explicit/multi-parametric MPC control of pressure swing adsorption systems

    KAUST Repository

    Khajuria, Harish

    2011-01-01

    Pressure swing adsorption (PSA) is a flexible, albeit complex gas separation system. Due to its inherent nonlinear nature and discontinuous operation, the design of a model based PSA controller, especially with varying operating conditions, is a challenging task. This work focuses on the design of an explicit/multi-parametric model predictive controller for a PSA system. Based on a system involving four adsorbent beds separating 70% H2, 30% CH4 mixture into high purity hydrogen, the key controller objective is to fast track H2 purity to a set point value of 99.99%. To perform this task, a rigorous and systematic framework is employed. First, a high fidelity detailed dynamic model is built to represent the system\\'s real operation, and understand its dynamic behavior. The model is then used to derive appropriate linear models by applying suitable system identification techniques. For the reduced models, a model predictive control (MPC) step is formulated, where latest developments in multi-parametric programming and control are applied to derive a novel explicit MPC controller. To test the performance of the designed controller, closed loop simulations are performed where the dynamic model is used as the virtual plant. Comparison studies of the derived explicit MPC controller are also performed with conventional PID controllers. © 2010 Elsevier Ltd. All rights reserved.

  10. CT of temporal bone - IV. inner ear

    International Nuclear Information System (INIS)

    Kwon, Jae Yoon; Sung, Kyu Bo; Youn, Eun Kyoung; Park, Youn Kyeung; Lee, Young Uk

    1990-01-01

    Temporal bone CT was done in 697 patients from April 1985 to October 1989. The abnormal findings were seen in 453 patients, which were chronic otitis media in 355 patients, fracture in 49 patients and congenital anomaly in 44 patients, etc. The abnormal findings of inner ear were observed on 46 patients. The results were summarized as follows : 1. The incidence of inner ear involvement by chronic otitis media was 7.3% (26/355 : labyrinthine fistula in 17 patients, labyrinthitis ossificans in 9 patients). Labyrinthine fistula was most commonly located on lateral semicircular canal (15/17, 88.2%). 2. Fusion of vestibule with lateral semicircular canal and formation of common cavity was demonstrated incidentally in 5 patients (0.7% of total number of temporal bone CT), and bilateral in 3 patients. 3. The incidence of inner ear anomaly in congenital ear anomaly was 11.4% (5/44). All cases were bilateral and three patients showed associated middle ear anomaly. 4. The incidence of involvement of bony labyrinth in temporal bone fracture was 10.2% (5/49). Labyrinthine fracture was seen all patients of transverse(3) and mixed fracture(1). In longitudinal fracture, labyrinthine fracture was seen in 2.2% (1/45). 5. Others were traumatic labyrinthitis ossificans(1), intracanalicular acoustic neuroma(3) and facial nerve neuroma(1)

  11. Evolution and development of the vertebrate ear

    Science.gov (United States)

    Fritzsch, B.; Beisel, K. W.

    2001-01-01

    This review outlines major aspects of development and evolution of the ear, specifically addressing issues of cell fate commitment and the emerging molecular governance of these decisions. Available data support the notion of homology of subsets of mechanosensors across phyla (proprioreceptive mechanosensory neurons in insects, hair cells in vertebrates). It is argued that this conservation is primarily related to the specific transducing environment needed to achieve mechanosensation. Achieving this requires highly conserved transcription factors that regulate the expression of the relevant structural genes for mechanosensory transduction. While conserved at the level of some cell fate assignment genes (atonal and its mammalian homologue), the ear has also radically reorganized its development by implementing genes used for cell fate assignment in other parts of the developing nervous systems (e.g., neurogenin 1) and by evolving novel sets of genes specifically associated with the novel formation of sensory neurons that contact hair cells (neurotrophins and their receptors). Numerous genes have been identified that regulate morphogenesis, but there is only one common feature that emerges at the moment: the ear appears to have co-opted genes from a large variety of other parts of the developing body (forebrain, limbs, kidneys) and establishes, in combination with existing transcription factors, an environment in which those genes govern novel, ear-related morphogenetic aspects. The ear thus represents a unique mix of highly conserved developmental elements combined with co-opted and newly evolved developmental elements.

  12. Ear Acupuncture in European Traditional Medicine

    Directory of Open Access Journals (Sweden)

    Luigi Gori

    2007-01-01

    Full Text Available Auricular acupuncture is a diagnostic and treatment system based on normalizing the body's dysfunction through stimulation of definite points on the ear. Rudimentary forms of acupuncture which probably arose during the Stone Age have survived in many parts of the world right down to present day. It was used in the ancient Egypt, Rome, Greece and all the Mediterranean area. It is a microacupuncture technique similar to reflexology, and was first described in France in 1950 by Paul Nogier who is considered the Father of modern ear acupuncture. It was speculated that the technique works because groups of pluripotent cells contain information from the whole organism and create regional organization centers representing different parts of the body. Nevertheless stimulation of a reflex point in the ear seems relieve symptoms of distant pathologies. Modern research is confirming the efficacy of ear acupuncture for analgesia and anxiety related disease, while tobacco dependence and other substance abuse still need confirmation. Actually main methodological problems with auricular acupuncture are that exist too many maps with little agreement regarding point location in the ear, and that the correspondence or reflex systems does not correlated with modern knowledge of anatomy and physiology.

  13. Follow-up of Antihypertensive Therapy Improves Blood Pressure Control: Results of HYT (HYperTension survey) Follow-up.

    Science.gov (United States)

    Fici, F; Seravalle, G; Koylan, N; Nalbantgil, I; Cagla, N; Korkut, Y; Quarti-Trevano, F; Makel, W; Grassi, G

    2017-09-01

    Although improved during the past few years, blood pressure control remains sub optimal. The impact of follow-up assessment on blood pressure control was evaluated in a group of patients of the HYT (HYperTension survey), treated with a combination of different dihydropyridine calcium-channel blockers (CCBs regimen) and inhibitors of renin-angiotensin-aldosterone system (RAAS) and with uncontrolled blood pressure. This was obtained assessing (a) the rate of blood pressure control at 3 and 6 months of follow-up in the whole group of patients, (b) the rate of blood pressure control and the average blood pressure values in subjects treated with different DHP-CCBs regimen. From the 4993 patients with uncontrolled blood pressure, (BP ≥ 140/90 or ≥140/85 in patients with diabetes), 3729 (mean age 61.2 ± 11.5 years), maintained CCBs regimen combined wih RAAS blockers and were evaluated at 3 and 6 months follow-up. At each visit BP (semiautomatic device, Omron-M6, 3 measurements), heart rate, adverse events and treatment persistence were collected. At 1st and 2nd follow-up the rate of controlled BP was 63.5 and 72.8% respectively (p blood pressure control; (b) there is no significant difference in the antihypertensive effect between different CCBs regimen; (c) lipophilic CCBs induce less ankle edema.

  14. Research on crystal growth by using pressure as a control parameter; Atsuryoku seigyo ni yoru kessho seicho ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-31

    This research project aims to establish a technique for crystal growth using pressure as a principal control parameter, and combining it with a microgravity condition, to develop a novel process material fabrication. Since the solubility of materials depends on pressure, it is possible to control a supersaturated condition for crystal growth by changing pressure. The growth condition can be controlled precisely, which is not possible by conventional methods that vary temperature and other factors. On the other hand, because a concentration diffusing field is formed autonomically around crystals in association with their growth, density convection is generated under gravity as a result of difference in the concentrations, making the growth conditions severely complex and uncontrollable. Ideal crystal growth condition control may be possible if the pressure control is performed under micro-gravity by which generation of the density convection can be suppressed. Realization has been achieved on in-situ observation by using high-magnification microscope which uses a diamond anvil cell, development of a hydraulic type optic pressure cell, and a high- speed crystal growing technology by means of pressure control utilizing the cell. New findings were also obtained on effects of pressure on crystal forms, and the pressure induced solid phase transfer mechanism. 67 refs., 49 figs., 3 tabs.

  15. Influence of isoflurane on the diastolic pressure-flow relationship and critical occlusion pressure during arterial CABG surgery: a randomized controlled trial.

    Science.gov (United States)

    Hinz, José; Mansur, Ashham; Hanekop, Gerd G; Weyland, Andreas; Popov, Aron F; Schmitto, Jan D; Grüne, Frank F G; Bauer, Martin; Kazmaier, Stephan

    2016-01-01

    The effects of isoflurane on the determinants of blood flow during Coronary Artery Bypass Graft (CABG) surgery are not completely understood. This study characterized the influence of isoflurane on the diastolic Pressure-Flow (P-F) relationship and Critical Occlusion Pressure (COP) during CABG surgery. Twenty patients undergoing CABG surgery were studied. Patients were assigned to an isoflurane or control group. Hemodynamic and flow measurements during CABG surgery were performed twice (15 minutes after the discontinuation of extracorporeal circulation (T15) and again 15 minutes later (T30)). The zero flow pressure intercept (a measure of COP) was extrapolated from a linear regression analysis of the instantaneous diastolic P-F relationship. In the isoflurane group, the application of isoflurane significantly increased the slope of the diastolic P-F relationship by 215% indicating a mean reduction of Coronary Vascular Resistance (CVR) by 46%. Simultaneously, the Mean Diastolic Aortic Pressure (MDAP) decreased by 19% mainly due to a decrease in the systemic vascular resistance index by 21%. The COP, cardiac index, heart rate, Left Ventricular End-Diastolic Pressure (LVEDP) and Coronary Sinus Pressure (CSP) did not change significantly. In the control group, the parameters remained unchanged. In both groups, COP significantly exceeded the CSP and LVEDP at both time points. We conclude that short-term application of isoflurane at a sedative concentration markedly increases the slope of the instantaneous diastolic P-F relationship during CABG surgery implying a distinct decrease with CVR in patients undergoing CABG surgery.

  16. High blood pressure in Panama: prevalence, sociodemographic and biologic profile, treatment, and control (STROBE).

    Science.gov (United States)

    Mc Donald Posso, Anselmo J; Motta Borrel, Jorge A; Fontes, Flavia; Cruz Gonzalez, Clara E; Pachón Burgos, Alvaro A; Cumbrera Ortega, Alberto

    2014-11-01

    The objective of this study is to estimate the prevalence, treatment, and control of high blood pressure, hypertension (HBP) in Panama and assess its associations with sociodemographic and biologic factors.A cross-sectional, descriptive study was conducted in Panama by administering a survey on cardiovascular risk factors to 3590 adults and measuring their blood pressure 3 times. A single-stage, probabilistic, and randomized sampling strategy with a multivariate stratification was used. The average blood pressure, confidence intervals (CIs), odds ratio (OR), and a value of P ≤ 0.05 were used for the analysis.The estimated prevalence of HBP was 29.6% (95% CI, 28.0-31.1); it was more prevalent in men than in women, OR = 1.37 (95% CI, 1.17-1.61); it increased with age and was more frequent among Afro-Panamanians (33.8%). HBP was associated with a family history of HBP with being physically inactive and a body mass index ≥25.0 kg/m or a waist circumference >90 cm in men and >88 cm in women (P control (<140/90 mm Hg).HBP is the most common cardiovascular risk factor among Panamanians and consequently an important public health problem in Panama. The health care system needs to give a high priority to HBP prevention programs and integrated care programs aimed at treating HBP, taking into consideration the changes in behavior that have been brought about by alterations in nutrition and sedentary lifestyles.

  17. Intraocular pressure control of a novel glaucoma drainage device - in vitro and in vivo studies

    Directory of Open Access Journals (Sweden)

    Li-Jun Cui

    2017-09-01

    Full Text Available AIM: To evaluate the intraocular pressure (IOP control of an artificial trabeculum drainage system (ATDS, a newly designed glaucoma drainage device, and postoperative complications in normal rabbit eyes. METHODS: Pressure drops in air and fluid of 30 ATDS were measured after being connected to a closed manometric system. Twenty of them were then chosen and implanted randomly into the eyes of 20 rabbits. Postoperative slit-lamp, gonioscopic examination and IOP measurements were recorded periodically. Ultrasound biomicroscopy and B-scan ultrasonography were also used to observe the complications. Eyes were enucleated on day 60. RESULTS: Pressure drops of 4.6-9.4 mm Hg were obtained at physiological aqueous flow rates in the tests in vitro. The average postoperative IOP of the experimental eyes (11.6-12.8 mm Hg was lower than the controls significantly (P<0.05 at each time point. Complications of hemorrhage (n=1, cellulosic exudation (two cases and local iris congestion (two cases were observed. The lumina of the devices were devoid of obstructions in all specimens examined and a thin fibrous capsule was found around the endplate. CONCLUSION: ATDS reduce IOP effectively. However, further studies on the structure are needed to reduce complications.

  18. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  19. Comparison of muzzle suppression and ear-level hearing protection in firearm use.

    Science.gov (United States)

    Branch, Matthew Parker

    2011-06-01

    To compare noise reduction of commercially available ear-level hearing protection (muffs/inserts) to that of firearm muzzle suppressors. Experimental sound measurements under consistent environmental conditions. None. Muzzle suppressors for 2 pistol and 2 rifle calibers were tested using the Bruel & Kjaer 2209 sound meter and Bruel & Kjaer 4136 microphone calibrated with the Bruel & Kjaer Pistonphone using Military-Standard 1474D placement protocol. Five shots were recorded unsuppressed and 10 shots suppressed under consistent environmental conditions. Sound reduction was then compared with the real-world noise reduction rate of the best available ear-level protectors. All suppressors offered significantly greater noise reduction than ear-level protection, usually greater than 50% better. Noise reduction of all ear-level protectors is unable to reduce the impulse pressure below 140 dB for certain common firearms, an international standard for prevention of sensorineural hearing loss. Modern muzzle-level suppression is vastly superior to ear-level protection and the only available form of suppression capable of making certain sporting arms safe for hearing. The inadequacy of standard hearing protectors with certain common firearms is not recognized by most hearing professionals or their patients and should affect the way hearing professionals counsel patients and the public.

  20. Customizing elastic pressure bandages for reuse to a predetermined, sub-bandage pressure: A randomized controlled trial.

    Science.gov (United States)

    Sermsathanasawadi, Nuttawut; Tarapongpun, Tanakorn; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Mutirangura, Pramook; Ruangsetakit, Chanean

    2017-01-01

    Objective A randomized clinical trial was performed to compare the effectiveness of unmarked bandages and customized bandages with visual markers in reproducing the desired sub-bandage pressure during self-bandaging by patients. Method Ninety patients were randomly allocated to two groups ("customized bandages" and "unmarked bandages") and asked to perform self-bandaging three times. The achievement of a pressure between 35 and 45 mmHg in at least two of the three attempts was defined as adequate quality. Results Adequate quality was achieved by 33.0% when applying the unmarked bandages, and 60.0% when applying the customized bandages ( p = 0.02). Use of the customized bandage and previous experience of bandaging were independent predictors for the achievement of the predetermined sub-bandage pressure ( p = 0.005 and p = 0.021, respectively). Conclusion Customized bandages may achieve predetermined sub-bandage pressures more closely than standard, unmarked, compression bandages. Clinical trials registration ClinicalTrials.gov (NCT02729688). Effectiveness of a Pressure Indicator Guided and a Conventional Bandaging in Treatment of Venous Leg Ulcer. https://clinicaltrials.gov/ct2/show/NCT02729688.